26
|
Naffah N, Ounsi H, Ozcan M, Bassal H, Salameh Z. Evaluation of the Adaptation and Fracture Resistance of Three CAD-CAM Resin Ceramics: An In vitro Study. J Contemp Dent Pract 2019; 20:571-576. [PMID: 31316020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
AIM The internal fit and resistance to fracture of resin ceramics are to be evaluated compared to that of lithium disilicate as the control group. MATERIALS AND METHODS Four groups of 20 crowns each (GC Cerasmart, Vita Enamic, Coltène Brilliant Crios, and e.max CAD) were cemented on identical metal dies. Marginal gaps were measured before cementation and load to fracture was applied after cementation, half of each group was thermodynamically aged (3,000 cycles of 5° to 55° immersion followed by 200,000 cycles of 100 N load), finally the crowns were loaded until fracture in a universal testing machine. Statistical package for social sciences (SPSS) package 23 was used for statistical work. RESULTS Marginal gaps ranged between 68.5 ± 23.8 µm and 87 ± 29.1 µm while occlusal gaps ranged from 220.7 ± 33.3 µm to 275.5 ± 46.5 µm and were not significantly different between groups. Fracture loads ranged from 633.8 ± 127.3 N to 1596.4 ± 497.7 N with lithium disilicate glass ceramics (LDGCs) and Enamic having higher values than resin nano-ceramics (RNCs). The fracture resistance was more related to material than aging and gap value. CONCLUSION The margin adaptation of resin ceramics was comparable to lithium disilicate with no significant difference. Lithium disilicate showed a higher resistance than resin ceramics and there was a higher resistance to fracture for polymer-infiltrated ceramic-network (PICN) than RNCs. CLINICAL SIGNIFICANCE Resin ceramics can have marginal adaptation and fracture resistance within clinical acceptance; therefore, they can be a good chair-side solution achieved in a single appointment session.
Collapse
|
27
|
El Ghoul WA, Özcan M, Ounsi H, Tohme H, Salameh Z. Effect of different CAD-CAM materials on the marginal and internal adaptation of endocrown restorations: An in vitro study. J Prosthet Dent 2019; 123:128-134. [PMID: 31027958 DOI: 10.1016/j.prosdent.2018.10.024] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2018] [Revised: 10/12/2018] [Accepted: 10/12/2018] [Indexed: 11/19/2022]
Abstract
STATEMENT OF PROBLEM Recent resin-based and ceramic-based computer-aided design and computer-aided manufacturing (CAD-CAM) materials have been used to restore endodontically treated teeth. Adaptation of the restoration is important for clinical success, but studies evaluating the effect of these materials on the adaptation of endocrowns are lacking. PURPOSE The purpose of this in vitro study was to evaluate the effect of resin-based and ceramic-based materials on the marginal and internal adaptation of endocrowns. MATERIAL AND METHODS Forty mandibular molars were divided into 4 groups (n=10); each group was restored with a different CAD-CAM material: group C: hybrid nanoceramic (Cerasmart; GC Corp), group T: fiber-composite material (Trilor; Bioloren Srl), group E: lithium disilicate glass-ceramic (IPS e.max CAD; Ivoclar Vivadent AG), and group V: zirconia-reinforced lithium silicate glass-ceramic (Vita Suprinity; VITA Zahnfabrik GmbH). A digital scan was made with an intraoral digital scanner (TRIOS 3; 3Shape A/S), and endocrowns were milled with a 5-axis milling machine (Coritec 250i; imes-icore GmbH). The replica technique and a stereomicroscope (×70) were used to measure the marginal and internal adaptation of the endocrowns at 32 points. All data were statistically analyzed using 1-way ANOVA and the Tukey honestly significant difference test (α=.05). RESULTS Statistical tests showed significant differences among the tested groups (P<.001). The resin-based groups displayed larger discrepancies than the ceramic-based groups. The resin-based groups showed a mean marginal gap larger than the mean internal gap C (P=.009), T (P<.001), whereas the ceramic-based groups showed similar gaps, V (P=.396), E (P=.936). The largest gap was observed at the pulpal floor (P<.001). CONCLUSIONS All materials had clinically acceptable internal and marginal gaps (≤150 μm), except for the marginal gap of the Trilor group.
Collapse
|
28
|
Moustapha G, Azzam K, AlShwaimi E, Silwadi M, Ferrari M, Salameh Z. Evaluation of the fit of zirconia three-unit fixed partial dentures fabricated by different impression techniques. ACTA ACUST UNITED AC 2019; 10:e12413. [PMID: 31001919 DOI: 10.1111/jicd.12413] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2018] [Revised: 02/21/2019] [Accepted: 02/22/2019] [Indexed: 12/01/2022]
Abstract
AIM The aim of the present study was to evaluate the marginal and internal fit of zirconium fixed partial denture using different impression techniques. METHODS A Nissin Typodont model, including maxillary central incisor and canine with missing lateral incisor, was selected for the present study. Thirty zirconium frameworks were fabricated following three impression techniques (N = 10), conventional silicone impression (group C), scanned dental impression (group S), and Trios 3 (3Shape) intraoral scanner (group T). An extra-fine milling strategy was applied. RESULTS Group T had the smallest discrepancy compared to groups C (P = 0.006) and S (P = 0.052) at the marginal level, whereas it was larger at the incisal tip. Discrepancies in group T were smaller than group C (P = 0.004) when measured at the axial walls, and smaller than group S (P = 0.045) when measured at the chamfer area for the central teeth only. Samples in group T showed a greater percentage of equally extended restorations (52.5%), while other groups were mainly underextended (group C: 63.7%, group S: 68.8%). CONCLUSION Better adaptation was achieved with the intraoral scanner group, except at the incisal tip. Conventional and scanned impressions revealed a greater percentage of underextended restorations.
Collapse
|
29
|
Moustapha G, AlShwaimi E, Silwadi M, Ounsi H, Ferrari M, Salameh Z. Marginal and internal fit of CAD/CAM fiber post and cores. INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY 2019; 22:45-53. [PMID: 30848254] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
AIM To evaluate the marginal adaptation and internal fit of milled fiber post and cores using different scanning methods. MATERIALS AND METHODS Thirty typodont tooth models (Nissin) with pulp cavity were endodontically treated and prepared to receive 30 fabricated fiber post and cores. Three different methods of scanning were used (n = 10): an intraoral scanner (IOS) (Trios 3; 3Shape) to directly digitalize the post space (Group T) and a laboratory scanner to indirectly digitalize the resin pattern (Group RP) and the silicone impression (Group S) of the post space. All the specimens were examined using an optical microscope for the measurement of the vertical marginal discrepancy (VMD), and five in each group were scanned using microcomputed tomography (µCT) for the assessment of the VMD, the internal fit at the corner (IFC), post apex (PA), and at four horizontal cross-sections (CS1-4) inside the canal. All data were analyzed using mixed-design ANOVA, followed by pairwise testing to identify the differences (α = 0.05). RESULTS Statistical analysis revealed that Group T was associated with the smallest cement space compared with Group RP (P = 0.001) and Group S (P < 0.001) for VMD using µCT or direct microscopy (OM) (P < 0.001). Similarly, the cement space for Group T was smaller than that of Group S (P = 0.039) when measured at the IFC (µCT), and smaller than Group RP (P = 0.025) when measured at CS1-4 (µCT), with CS1 larger than CS3 (P = 0.015). There was no significant difference at PA (P = 0.271). CONCLUSION Better adaptation was achieved with a complete digital workflow. Scanning the resin pattern or the silicone impression introduced more variables in the digital process or milling of a one-piece fiber post and core.
Collapse
|
30
|
Eid R, Juloski J, Ounsi H, Silwaidi M, Ferrari M, Salameh Z. Fracture Resistance and Failure Pattern of Endodontically Treated Teeth Restored with Computer-aided Design/ Computer-aided Manufacturing Post and Cores: A Pilot Study. J Contemp Dent Pract 2019; 20:56-63. [PMID: 31102396] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
AIM To evaluate the fracture resistance and failure pattern of custom made computer-aided design & computer-aided manufacturing (CAD/CAM) post and cores using a fiber reinforced composite material (FRC) and a high-density-polymer. MATERIALS AND METHODS Thirty extracted mandibular second premolars were selected, endodontically treated and prepared to receive the posts. The specimens were randomly divided into three groups (n = 10) according to each material: group 1 (RXP) : fiber posts (Rely X, 3M-ESPE) with composite core build-up (Filtek Bulk Fill Posterior, 3M-ESPE) as a control group; group 2 (BLC): one-piece milled post and core from fiber reinforced composite blocks (Trilor, Bioloren); and group 3 (AMC): one-piece milled post and core from hybrid ceramic disks (Ambarino, Creamed). All the posts were cemented using a self-adhesive resin cement (Rely X U200, 3M ESPE). Fracture resistance was tested using a universal testing machine, failure patterns were then observed visually and radiographically then evaluated under SEM. Data was analyzed using One-way analysis of variance (ANOVA) followed by Tamhane post-hoc test in order to determine significant differences among groups (α = 0.05). RESULTS The mean fracture resistance values were: 426.08 ± 128.26 N for group 1 (R X P), 367.06 ± 72.34N for group 2 (BLC), and 620.02 ± 54.29N for group 3 (AMC). Statistical analysis revealed that group 3 (AMC) had the highest mean load to fracture in comparison to the other groups (p = 0.000). failures were cohesive in group 2 and 3 and mixed in group 1 with no catastrophic failures reported in all groups. CONCLUSION All systems evaluated presented sufficient mean load-to-failure values for endodontically treated teeth restorations. CAD/CAM post and cores made from high-density-polymer showed a better performance than prefabricated fiber posts.
Collapse
|
31
|
Raj AT, Patil S, Sarode S, Salameh Z. P-Hacking: A Wake-Up Call for the Scientific Community. SCIENCE AND ENGINEERING ETHICS 2018; 24:1813-1814. [PMID: 29071570 DOI: 10.1007/s11948-017-9984-1] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/18/2017] [Accepted: 10/06/2017] [Indexed: 06/07/2023]
Abstract
P-hacking or data dredging involves manipulation of the research data in order to obtain a statistically significant result. The reasons behind P-hacking and the consequences of the same are discussed in the present manuscript.
Collapse
|
32
|
Tohme H, Makzoume J, Boulos P, Fakhoury J, Yared C, Salameh Z, Daou M. Effect of Cyclic Dislodging on the Retention of Two Attachment Systems for Implant-supported Overdentures: An In Vitro Study. J Contemp Dent Pract 2018; 19:1386-1392. [PMID: 30602646] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
PURPOSE The aim of this study was to compare and evaluate the retention of two new attachment systems used for implant-supported overdentures subjected to insertion-removal cycles. MATERIALS AND METHODS Twenty custom-manufactured polyvinyl chloride models mimicking implant-retained over-dentureresin blocks were fabricated and divided into two groups (n = 10): group 1 ('Kerator' attachment) and group 2 ('EMI' attachment). Each model received two parallel implants (JD evolution®) 20 mm apart and was subjected to cyclic retention forces of 10, 100, 1000, 5000, 10000 and 14600 cycles using a universal testing machine in a 0.9% sodium chloride water solution at 22° C. Data were analyzed using one-way analysis of variance; the level of significance was set at a < 0.05. RESULTS The 'Kerator' and 'EMI' attachment systems reported a significant decrease in retention (64 and 56.6% respectively) after 14600 insertion-removal cycles (p < 0.001). The 'EMI' attachment showed significant higher loss of retention than the 'Kerator' attachment all along the 14600 cycles (p < 0.05) except for cycles 100 and 5000 (p > 0.05). CONCLUSION Within the limitations of this in vitro study, both attachments reported satisfactory retentive values during the 14600 cycles, the 'Kerator' attachment showed better retention than the new 'EMI' attachment. The initial retentive force of both attachments has gradually decreased. CLINICAL SIGNIFICANCE Both attachment systems evaluated in this study can be used in clinical practice for implant-supported overdentures.
Collapse
|
33
|
Daou EE, Özcan M, Salameh P, Al-Haj Husain N, Salameh Z. Comparison of Adhesion of a Novel Pre-sintered Cobalt-Chromium to Pre-sintered Zirconia and Cast Nickel-Chromium. J Contemp Dent Pract 2018; 19:816-823. [PMID: 30066685] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
AIM This study compared the bond strength of pre-sintered Ceramill Sintron to pre-sintered zirconia and cast nickel-chromium (NiCr). MATERIALS AND METHODS Specimens (n = 60) (diameter: 15 mm; thickness: 2 mm) were prepared (n = 20/group) (Ceramill Sintron, Ceramill Zi, and Wirobond 99). Disks were layered with vita VM ceramic (4 mm). Specimens were randomly divided into two subgroups. Only one subgroup was thermocycled. Specimens were tested under shear strength. Energy-dispersive X-ray (EDX) mapping was done on one disk of each material before and after ceramic layering. RESULTS Failure types were mostly mixed failures. Significant difference was found between the three materials for Y and Z failure types (p-values: 0.032 and 0.010 respectively). Thermocycling had no major effect on the results reported. Considering Fmax (force-inducing bonding failure) registered, significant difference was found between the control group and milled alloys groups. No significant difference was found between Ceramill Sintron and Zi. The EDX mapping showed a net increase in the control group oxide layer, whereas only slight increase and decrease were reported for Zi and Sintron respectively. CONCLUSION When compared with cast NiCr, novel Ceramill Sintron has higher bond strength, comparable to Ceramill Zi. Thermocycling had no major effects on the results. CLINICAL SIGNIFICANCE Ceramic-alloy bonding is a primary factor in the prosthesis' longevity.
Collapse
|
34
|
Daou EE, Ounsi H, Özcan M, Al-Haj Husain N, Salameh Z. Marginal and internal fit of pre-sintered Co-Cr and zirconia 3-unit fixed dental prostheses as measured using microcomputed tomography. J Prosthet Dent 2018; 120:409-414. [PMID: 29724558 DOI: 10.1016/j.prosdent.2018.01.006] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2016] [Revised: 01/09/2018] [Accepted: 01/09/2018] [Indexed: 10/17/2022]
Abstract
STATEMENT OF PROBLEM Limited information is available on the precision of new metal processing technologies. PURPOSE The purpose of this in vitro study was to evaluate the marginal and internal fit of pre-sintered cobalt-chromium (Co-Cr) and zirconia 3-unit fixed dental prostheses using x-ray microcomputed tomography. MATERIAL AND METHODS Three-unit fixed dental prostheses were prepared on metal dies (N=12) using a typodont model from the maxillary first premolar to the first molar. A standardized preparation with a 1.2-mm chamfer (360 degrees) and a 2-mm occlusal reduction was prepared on abutment teeth. The dies were scanned and divided into 2 groups to receive the fixed dental prostheses (n=6) made of pre-sintered Co-Cr and pre-sintered zirconia. Each framework was seated on its cast, and marginal and internal discrepancies were measured at 9 points, starting from the most distal point from the pontic for the maxillary first premolar and the first molar (points 1-4, mesial; point 5, occlusal; points 6-9, distal) of each abutment tooth using microcomputed tomography. The data were analyzed using the Levene test, t test, and ANOVA (α=.05). RESULTS When overall mean discrepancy values were compared, no significant difference was observed between pre-sintered Co-Cr and pre-sintered zirconia (P=.085). Discrepancy values for points 1, 2, and 3 were significantly different for pre-sintered Co-Cr and pre-sintered zirconia, with the lowest mean values for point 1 and the highest for point 5. On the abutment tooth basis, for the maxillary first premolar and the first molar, a significant difference was found only in points 6 (P<.001) and 8 (P<.003) for both materials. When the discrepancies for the maxillary first premolar were considered for pre-sintered Co-Cr and pre-sintered zirconia, the mean values were significantly different only at points 1 (P<.001), 2 (P=.007), and 3 (P=.003) and were smaller for pre-sintered zirconia. For the tooth the first molar, a significant difference was observed at point 2 (P=.002) and point 3 (P=.008) for both materials, where the mean values were higher for pre-sintered Co-Cr than for pre-sintered zirconia. The pairwise comparison between points showed a significant difference between measurement points within each material (P<.05). The increase in values between points 1 and 5 was evident for both pre-sintered Co-Cr and pre-sintered zirconia materials. CONCLUSIONS Three-unit fixed dental prostheses made of pre-sintered Co-Cr or zirconia showed similar marginal and internal discrepancy values, with the highest discrepancy values at the occlusal region in both the first premolar and first molar.
Collapse
|
35
|
Skienhe H, Habchi R, Ounsi HF, Ferrari M, Salameh Z. Structural and Morphological Evaluation of Presintered Zirconia following Different Surface Treatments. J Contemp Dent Pract 2018; 19:156-165. [PMID: 29422464 DOI: 10.5005/jp-journals-10024-2230] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
AIM The aim of this study was to evaluate the effect of different surface treatments on roughness, grain size, and phase transformation of presintered zirconia. MATERIALS AND METHODS Surface treatments included airborne particle abrasion (APA) before and after sintering with different particles shape, size, and pressure (50 μm Al2O3, 50 μm glass beads, and ceramic powder). Thirty-five square-shaped presin-tered yttrium-stabilized tetragonal zirconia polycrystal (Y-TZP) ceramic slabs (Zenostar ZR bridge, Wieland) were prepared (4 mm height × 10 mm width × 10 mm length) and polished with silicon carbide grit papers #800, 1000, 1200, 1500, and 2000 to ensure identical initial roughness. Specimens were divided into five groups according to surface treatment: group I (control): no surface treatment; group II: APA 50 μm Al2O3 after sintering; group III: APA 50 μm Al2O3 particles before sintering; group IV: APA 50 μm glass bead particles before sintering; and group V: APA ceramic powder before sintering. Specimens were analyzed using scanning electron microscopy (SEM), atomic force microscopy (AFM), X-ray diffraction (XRD) analyses, and tested for shear bond strength (SBS). Data were statistically analyzed using one-way analysis of variance (ANOVA) followed by post hoc tests for multiple comparisons Tukey's test (a > 0.05). RESULTS Air abrasion before sintering significantly increased the surface roughness when compared with groups I and III. The highest tetragonal to monoclinic (t-m) phase transformation (0.07%) was observed in group III, and a reverse transformation was observed in presintered groups (0.01%). Regarding bond strength, there was a significant difference between APA procedures pre- and postsintering. CONCLUSION Air abrasion before sintering is a valuable method for increasing surface roughness and SBS. The abrasive particles' size and type used before sintering had a little effect on phase transformation. CLINICAL SIGNIFICANCE Air abrasion before sintering could be supposed to be an alternative surface treatment method to air abrasion after sintering.
Collapse
|
36
|
Ounsi HF, Nassif W, Grandini S, Salameh Z, Neelakantan P, Anil S. Evolution of Nickel-titanium Alloys in Endodontics. J Contemp Dent Pract 2017; 18:1090-1096. [PMID: 29109327 DOI: 10.5005/jp-journals-10024-2181] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
UNLABELLED To improve clinical use of nickel-titanium (NiTi) endodontic rotary instruments by better understanding the alloys that compose them. A large number of engine-driven NiTi shaping instruments already exists on the market and newer generations are being introduced regularly. While emphasis is being put on design and technique, manufacturers are more discreet about alloy characteristics that dictate instrument behavior. Along with design and technique, alloy characteristics of endodontic instruments is one of the main variables affecting clinical performance. Modification in NiTi alloys is numerous and may yield improvements, but also drawbacks. Martensitic instruments seem to display better cyclic fatigue properties at the expense of surface hardness, prompting the need for surface treatments. On the contrary, such surface treatments may improve cutting efficiency but are detrimental to the gain in cyclic fatigue resistance. Although the design of the instrument is vital, it should in no way cloud the importance of the properties of the alloy and how they influence the clinical behavior of NiTi instruments. CLINICAL SIGNIFICANCE Dentists are mostly clinicians rather than engineers. With the advances in instrumentation design and alloys, they have an obligation to deal more intimately with engineering consideration to not only take advantage of their possibilities but also acknowledge their limitations.
Collapse
|
37
|
Ayoub F, Jassar H, El Husseini H, Salameh Z. Choice of Endodontic Fiber Posts and its Influence on Dental Malpractice: An in vitro Evaluation. J Contemp Dent Pract 2017. [PMID: 28621273 DOI: 10.5005/jp-journals-10024-2064] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
AIMS AND OBJECTIVES The fiber post type used in restoring endodontically treated teeth may affect the dental expert decision in the case of dental malpractice. The aim of this study was to evaluate the low-cost commercial fiber post in comparison with a higher cost or well-known documented fiber post system. MATERIALS AND METHODS A total of 20 premolars were selected for the study; following endodontic treatment, specimens were randomly divided into two groups of 10 specimens each according to the type of fiber post used: (1) Low-cost commercial fiber post (OYAPost, Taper Lucent, OYARICOM) and (2) higher cost well-known fiber post (Rely X Fiber post, 3M ESPE). Both fiber posts were cemented using self-adhesive cement (Rely X Unicem). Samples were subjected to push-out bond strength and to failure analysis. One-way analysis of variance was used (p < 0.005). RESULTS There was no significant difference between the bond strength of the two tested groups (p > 0.05), while statistically significant difference (p < 0.05) was noted between the different post space regions (cervical, middle, and apical). CONCLUSION Based on the evidence from the study, it can be concluded that the type of fiber post should not affect the dental expert decision in the case of dental malpractice/lawsuit. CLINICAL SIGNIFICANCE All types of low-cost fiber posts may behave similarly to other higher cost or well-documented fiber posts.
Collapse
|
38
|
Diab HA, Salameh Z, Hamadeh GN, Younes G, Ayoub F. Oral Health Status of Institutionalized Individuals with Intellectual Disabilities in Lebanon. EJOURNAL OF ORAL MAXILLOFACIAL RESEARCH 2017; 8:e4. [PMID: 28496964 PMCID: PMC5423309 DOI: 10.5037/jomr.2017.8104] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 02/10/2017] [Accepted: 03/29/2017] [Indexed: 12/20/2022]
Abstract
OBJECTIVES To assess the dental status of institutionalized intellectually disabled individuals in Lebanon and the role of background and behavioural determinants. MATERIAL AND METHODS Oral health was recorded for 652 individuals (6, 12, 15 and 35 - 44 years old) using the decayed, missing and filled teeth/decayed and filled teeth (DMFT/dft) index. Data collected was statistically analysed with statistical significance set at P = 0.05. RESULTS Overall, mean DMFT index score was 5.86 (SD 6); composed of 3.64 (SD 4.05) decayed (D) teeth; 1.71 (SD 4.38) missing (M) teeth; 0.87 (SD 2.51) filled (F) teeth. DMFT was highest in adults (12.71 [SD 7.43]) and had a large component of missing (6.24 [SD 7.02]) and filled (3.31 [SD 4.56]) teeth. DMFT scores ranged between 3.5 (SD 4.44) at 6 years and 4.8 (SD 4.52) at 15 years and the decayed component was the main contributor. In multivariate analyses, governorate of residence was statistically significantly (P ≤ 0.040 and P ≤ 0.044) associated with D and DMFT, the degree of disability and caretaker educational level were statistically significantly (P = 0.009 and P = 0.008) associated with D, oral hygiene practices were statistically significantly (P ≤ 0.017; P < 0.001; P ≤ 0.017; P < 0.001) associated with D, M, F and DMFT and sugar consumption was statistically significantly (P ≤ 0.03 and P ≤ 0.019) associated with D and DMFT. CONCLUSIONS In Lebanon, preventive and treatment programs to improve the oral health status of institutionalized intellectually disabled subjects are needed.
Collapse
|
39
|
Tae Young A, Kang JH, Kang DJ, Venkatesan J, Chang HK, Bhatnagar I, Chang KY, Hwang JH, Salameh Z, Kim SK, Kim HT, Kim DG. Interaction of stem cells with nano hydroxyapatite-fucoidan bionanocomposites for bone tissue regeneration. Int J Biol Macromol 2016; 93:1488-1491. [DOI: 10.1016/j.ijbiomac.2016.07.027] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2015] [Revised: 07/05/2016] [Accepted: 07/07/2016] [Indexed: 10/21/2022]
|
40
|
Mirmohammadi H, Gerges E, Salameh Z, Wesselink PR. Effect of post diameter and cement thickness on bond strength of fiber posts. QUINTESSENCE INTERNATIONAL (BERLIN, GERMANY : 1985) 2015; 44:801-10. [PMID: 23878848 DOI: 10.3290/j.qi.a30179] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
OBJECTIVE This study evaluated the effects of different post diameter and oversized post spaces on the push-out bond strength of a fiber post to dentin. METHOD AND MATERIALS Fifty extracted human maxillary central incisors and canines were divided into five groups and submitted to the push-out test (0.5 mm min-1). Groups 1, 2, and 3 were restored using a fiber post size that was identical to the drill size (sizes 1, 2, and 3, respectively), and groups 4 and 5 were both prepared with drill size 3, and restored using the size 2 and 1 fiber post, respectively. The fiber posts were cemented using self-adhesive dual-polymerized resin cement (RelyX Unicem). The data were analyzed using a one-way analysis of variance (ANOVA) and the Tukey test. RESULTS There were no significant differences in the mean values for push-out bond strength between groups with different post diameters (P > .05). However, the push-out bond strengths were significantly different between groups with different cement thicknesses, and group 4 yielded the highest bond strength (11.7 ± 0.4 MPa). For all groups, the apical third had the lowest bond strength value (P < .05). CONCLUSION The highest push-out bond strength values were obtained when one incremental oversized post space was used. Clinically, fiber post space has to provide an optimum cement thickness (around 120 µm) for adequate cementation.
Collapse
|
41
|
Berberi A, Bouserhal L, Nader N, Assaf RB, Nassif NB, Bouserhal J, Salameh Z. Evaluation of Three-Dimensional Volumetric Changes After Sinus Floor Augmentation with Mineralized Cortical Bone Allograft. J Maxillofac Oral Surg 2015; 14:624-9. [PMID: 26225054 PMCID: PMC4511887 DOI: 10.1007/s12663-014-0736-3] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2014] [Accepted: 12/04/2014] [Indexed: 11/24/2022] Open
Abstract
AIM The aim of this retrospective study was to quantify three-dimensional (3D) volumetric bone changes over a two-year period in maxillary sinuses augmented with a mineralized cortical bone allograft material (MCBA) material. PATIENTS AND METHODS Eleven patients (6 males and 5 females) with mean of age of 51.6 (range: 46-61) years were treated to increase the vertical dimension of the alveolar crest by maxillary sinus floor augmentation procedure. Study data were collected from patient records and by analyzing preoperative radiographs and cone beam computed tomography (CBCT) scans taken within the first two weeks after maxillary sinus lift (T0), immediately before implant placement four months after grafting (T1), and after one year of implant loading (T2). All DICOM-formatted images were rendered into volumetric images using software that automatically calculated the volume of the grafted material in cubic centimeters. RESULTS Mean graft volume was 16.24 ± 1.54 cm(3) at T0, 14.48 ± 1.48 cm(3) at T1 and 13.06 ± 1.39 cm(3) at T2. Mean volume retraction resulted in 1.76 ± 0.34 cm(3) ΔV1 (T0-T1) and 1.42 ± 0.4 cm(3) ΔV2 (T1-T2) and was 10.83 % of the initial total volume at (T0-T1) and 9.8 % of the total volume (T1-T2). CONCLUSION The present retrospective investigation demonstrated a 20.63 % decrease in graft volume. Volumetric 3D assessment of CBCT scans with the selected software appeared to be a promising approach to quantifying long-term changes in the grafted area.
Collapse
|
42
|
Berberi A, Nader N, Noujeim Z, Scardina A, Leone A, Salameh Z. Horizontal and vertical reconstruction of the severely resorbed maxillary jaw using subantral augmentation and a novel tenting technique with bone from the lateral buccal wall. J Maxillofac Oral Surg 2015; 14:263-70. [PMID: 26028846 DOI: 10.1007/s12663-014-0635-7] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2013] [Accepted: 06/10/2014] [Indexed: 11/27/2022] Open
Abstract
AIM The aim of this study was to evaluate the effect of using the lateral wall bone in sinus lifting two-dimensional reconstruction on bone augmentation. PATIENTS AND METHODS Ten patients affected by class V or VI maxillary atrophy with less than 3 mm of residual horizontal ridge were selected. Using a piezo-ultrasonic surgery tip bony lateral wall was cut. To expose native bone to the bone graft, multiple perforations, made through the cortical plate of the recipient site with a round bur. Once the bony buccal wall was adjusted it was fixed away from the ridge with two 1.5 x 13 mm bone fixation screws. Deficiencies created between the bony buccal wall and the ridge was filled with a mineralized cortical bone. A pericardium membrane was then placed on the graft. A biopsy for histologic evaluation was made. RESULTS The data analysis in bone volume changes reported significant differences between the anterior and posterior locations before and after grafting (p < 0.05). The biopsy shows mature cancellous bone with predominantly lamellar structure. CONCLUSION The use of the lateral wall bone in sinus lift surgery showed significant increase in bone volume.
Collapse
|
43
|
Ayoub F, Nehme E, Jad S, Salameh Z. A Novel Approach for the Reimbursement of Permanent Partial Dental Disability Following Dental Injury. J Contemp Dent Pract 2015; 16:504-6. [PMID: 26323454 DOI: 10.5005/jp-journals-10024-1712] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
Reimbursement of long-term permanent disability following a dental injury can lead to claims and legal involvement by the injured person. This will delay the treatment the patient's quality of life and the court system. A new formula has been hypothesized to address the problem. This might help the stakeholders including patients, insurance companies. The details of calculating the index and its significance are discussed. Implication studies are mandatory to refine the proposed hypothesis.
Collapse
|
44
|
Almas K, Salameh Z, Kutkut A, Al Doubali A. A Simplified Technique to Measure Plaque on the Intaglio Surfaces of Complete Dentures. JOURNAL OF THE INTERNATIONAL ACADEMY OF PERIODONTOLOGY 2015; 17:58-64. [PMID: 26242012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
OBJECTIVE The main aim of this study was to develop a simplified quantitative denture plaque index that could help dentists to motivate denture patients to maintain optimal oral hygiene. The secondary aim was to assess specific areas of dentures more prone to accumulate plaque and subjects' oral hygiene habits related to their dentures. METHODS One hundred subjects who wore maxillary and/or mandibular complete dentures for at least one year were included in the study as a powered sample. Fifteen females and 85 males, age range 45-75 years, were recruited. The study was carried out at King Saud University (KSU), College of Dentistry. A plaque disclosing solution was used to assess the plaque covered areas of denture. A quantitative percentage (10 x 10%) score index was developed by assessing plaque scores from digital images of intaglio surfaces of the dentures. The weighted kappa method was used to assess inter-examiner agreement in the main study. RESULTS The new denture plaque index was identified as ASKD-DPI (Almas, Salameh, Kutkut, and Doubali-Denture Plaque Index). It ranged from 0 - 100%, and reflected the percentage of the intaglio surfaces of maxillary and mandibular complete dentures that contained plaque. It also classified quantitative percentages: 30 subjects ranged from 0 - 30% (low DPI), 50 subjects ranged from 31 - 70% (moderate DPI), and 20 subjects ranged from 71 - 100% (high DPI) denture plaque score. CONCLUSIONS A simplified denture plaque index (ASKD-DPI) technique was developed and tested in this study. ASKD-DPI may be used for evaluating denture plaque scores, monitoring denture hygiene, and measuring compliance of patients regarding plaque control for complete dentures.
Collapse
|
45
|
Riachi F, Naaman N, Tabarani C, Berberi A, Salameh Z. Comparison of morbidity and complications of harvesting bone from the iliac crest and calvarium: a retrospective study. J Int Oral Health 2014; 6:32-35. [PMID: 25083030 PMCID: PMC4109241] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2013] [Accepted: 03/21/2014] [Indexed: 06/03/2023] Open
Abstract
BACKGROUND The aim of this retrospective clinical study was to compare the complications after the harvest of bone from the iliac crest and the calvarium. MATERIALS AND METHODS One hundred and eighty patients were selected for this study (125 iliac crest and 55 calvarium donor sites). Data were collected from the medical records and classified as major or minor complications for each procedure. RESULTS The highest percentage of total complications (66.4%) was recorded when the iliac crest was harvested. The highest percentage of major complications was associated with the harvest of calvarium site (14.5%), while highest percentage of minor complications was associated with the harvest of the iliac site (60.8%). CONCLUSION Harvesting of the iliac crest was associated with the highest percentage of complications. Major complications were more observed with harvesting of the calvarium. How to cite the article: Riachi F, Naaman N, Tabarani C, Berberi A, Salameh Z. Comparison of morbidity and complications of harvesting bone from the iliac crest and calvarium: A retrospective study. J Int Oral Health 2014;6(3):32-5.
Collapse
|
46
|
Salameh Z, Tehini G, Ziadeh N, Ragab HA, Berberi A, Aboushelib MN. Influence of ceramic color and translucency on shade match of CAD/CAM porcelain veneers. THE INTERNATIONAL JOURNAL OF ESTHETIC DENTISTRY 2014; 9:90-97. [PMID: 24757701] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
OBJECTIVE To investigate the influence of translucency of CAD/CAM ceramic milling blocks on the final color of porcelain veneer cemented using resin cement with two different opacities. MATERIALS AND METHODS A standardized incisal lap preparation was made on a maxillary right central incisor that was duplicated using composite resin material (Z250, A4, 3M ESPE). The resin dies were individually laser scanned (Bluecam, Sirona) in order to build a 3D model of the porcelain veneer on the CAD software (Cerec 3D). Three types of milling blocks were used to fabricate the required restorations: multichromatic, high translucency, and low translucency milling blocks (IPS Empress CAD, A1 Vita shade tab). The milled veneers were polished, glazed, and bonded on the resin dies using high opacity and low opacity resin cements (Panavia F2.0). A digital shade guide device (Easyshade Advance, Vita) was used to measure color parameters (CIE Lab values) at the incisal, middle, and cervical third of each cemented restoration. ΔE values of the cemented veneers were calculated against the target color (A1). RESULTS Cementation of porcelain veneers resulted in significant color change of the resin die (A4) as ΔE values ranged between 8.9 and 13.7. However, the type of milling block did not have an observable effect on final color as the measured ΔE values, against original die color, were very close for the multichromatic block (ΔE = 10.7 ± 0.1), high translucency (ΔE = 9.7 ± 0.09), and low translucency blocks (ΔE = 13.4 ± 0.11). The opacity of the used resin cement did not affect the final shade match, as the observed ΔE values using either high opacity and low opacity resin cement were less than 2 for the three used ceramic blocks. The greatest color difference was observed between the incisal third of multichromatic veneers (ΔE = 8.9) and the cervical third of low translucency veneers (ΔE = 13.7), while for the rest of the test groups this shift was not clinically observable (ΔE < 2.5). CONCLUSION Within the limitations of this study, the shade match of CAD/CAM porcelain veneers was not influenced by the translucency of used milling block or the opacity of the resin cement.
Collapse
|
47
|
Al-Amri M, Al-Madi E, Sadig WM, Ahmedani MS, Salameh Z. Significance of primary factors influencing students' performance at the College of Dentistry, King Saud University, Saudi Arabia. J PAK MED ASSOC 2012; 62:816-821. [PMID: 23862257] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
OBJECTIVE To determine the effect of different enabling factors such as curriculum, role of faculty, academic advising and availability of learning resources and supportive services on the performance of students pursuing their Bachelor's degree in dentistry. METHODS Data was collected from the male and female students of the College of Dentistry, King Saud University, during the academic year 2008-2009. All undergraduate students (576) constituted the total sample size of the study. The respondents were requested to fill a questionnaire form, which was specially designed in accordance with requirements of the Association for Dental Education in Europe (ADEE). The questionnaire comprised 45 questions addressing all aspects of the relevant factors. The five-point Likert scale was used to evaluate the feedback. All the responses (239) were thoroughly examined and only the completely filled forms (169) were subjected to regression analyses, taking student's CGPA as a dependent factor and a depiction of their performance. The t-tests were also worked out to evaluate variations in the responses of male and female students to each sub-factor. RESULTS The study showed a significant impact of faculty and learning resources and support services on a student's achievement (alpha = 0.05). Surprisingly, academic advising and the dental curriculum had non-significant effect at 95% level of confidence. However, the critical analyses acknowledged that the non-significant impact was due to poor performance of the two factors. CONCLUSION The role of faculty and learning resources as well as of support services had significant effect on students' performance. However, there is an immense need to improve the level of academic advising and revise the curriculum to have a significant impact of these factors on the student's achievements.
Collapse
|
48
|
Abualsaud H, Zandparsa R, Hirayama H, Sadig W, Aboushelib M, Salameh Z. Color management of the cervical region using different framework materials. J ESTHET RESTOR DENT 2011; 23:371-8. [PMID: 22142295 DOI: 10.1111/j.1708-8240.2010.00387.x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
BACKGROUND Color-matching of the cervical area between natural teeth and different crown prostheses is a common clinical problem. PURPOSE The purpose of this study was to compare the color of the cervical region of five commercially available crown systems to an extracted natural tooth and to each other. MATERIALS AND METHODS The color of the cervical region of an extracted maxillary incisor was measured by means of a colorimeter (ShadeVision, X-Rite). Fifty master dies were fabricated, divided into five groups (N=10) according to the framework material; group 1: high-noble gold alloy, group 2: same as group 1 but treated with gold paste material, group 3: precious reinforced alloy, group 4: white zirconium oxide substructure (Lava 3M ESPE), and group 5: shaded zirconium oxide (Lava). A direct comparison of L*, a*, and b* parameters was accomplished between the control natural tooth and the five crown systems, and the mean color differences (ΔE) was calculated. The data were statistically analyzed with one-way analysis of variance and post hoc multiple comparison (α=0.05). RESULTS Compared to the natural tooth, the mean color differences (ΔE) values were clinically unacceptable for all groups (ΔE > 3.7). The detected color differences, among different porcelain systems, were not visually perceptible (ΔE < 3.7). CONCLUSIONS Within the limitations of this study, the cervical color of an extracted natural tooth could not be duplicated using different crowns systems. CLINICAL SIGNIFICANCE Color-matching of the cervical region of different crown systems with natural tooth remains a difficult task.
Collapse
|
49
|
Sherfudhin H, Hobeich J, Carvalho CA, Aboushelib MN, Sadig W, Salameh Z. Effect of different ferrule designs on the fracture resistance and failure pattern of endodontically treated teeth restored with fiber posts and all-ceramic crowns. J Appl Oral Sci 2011; 19:28-33. [PMID: 21437466 PMCID: PMC4245860 DOI: 10.1590/s1678-77572011000100007] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2009] [Accepted: 10/06/2009] [Indexed: 11/28/2022] Open
Abstract
Objective This study investigated the effect of different ferrule heights on endodontically
treated premolars. Materials and Methods Fifty sound mandibular first premolars were endodontically treated and then
restored with 7-mm fiber post (FRC Postec Plus #1 Ivoclar-Vivadent) luted with
self-polymerized resin cement (Multilink, Ivoclar Vivadent) while the coronal
section was restored with hybrid composite core build-up material (Tetric Ceram,
Ivoclar-Vivadent), which received all-ceramic crown. Different ferrule heights
were investigated: 1-mm circumferential ferrule without post and core (group 1
used as control), a circumferential 1-mm ferrule (group 2), non-uniform ferrule
2-mm buccally and 1-mm lingually (group 3), non-uniform ferrule 3-mm buccally and
2-mm lingually (group 4), and finally no ferrule preparation (group 5). The
fracture load and failure pattern of the tested groups were investigated by
applying axial load to the ceramic crowns (n=10). Data were analyzed statistically
by one-way ANOVA and Tukey’s post-hoc test was used for pair-wise
comparisons (α=0.05). Results There were no significant differences among the failure load of all tested groups
(P<0.780). The control group had the lowest fracture resistance
(891.43±202.22 N) and the highest catastrophic failure rate
(P<0.05). Compared to the control group, the use of fiber post reduced the
percentage of catastrophic failure while increasing the ferrule height did not
influence the fracture resistance of the restored specimens. Conclusions Within the limitations of this study, increasing the ferrule length did not
influence the fracture resistance of endodontically treated teeth restored with
glass ceramic crowns. Insertion of a fiber post could reduce the percentage of
catastrophic failure of these restorations under function.
Collapse
|
50
|
Al-Hezaimi K, Salameh Z, Al-Fouzan K, Al Rejaie M, Tay FR. Histomorphometric and Micro–computed Tomography Analysis of Pulpal Response to Three Different Pulp Capping Materials. J Endod 2011; 37:507-12. [DOI: 10.1016/j.joen.2010.11.001] [Citation(s) in RCA: 40] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2010] [Revised: 11/05/2010] [Accepted: 11/06/2010] [Indexed: 01/09/2023]
|