Nguyen HG, van den Berg NS, Antaris AL, Xue L, Greenberg S, Rosenthal JW, Muchnik A, Klaassen A, Simko JP, Dutta S, Sorger JM, Munster P, Carroll PR. First-in-human Evaluation of a Prostate-specific Membrane Antigen-targeted Near-infrared Fluorescent Small Molecule for Fluorescence-based Identification of Prostate Cancer in Patients with High-risk Prostate Cancer Undergoing Robotic-assisted Prostatectomy. Eur Urol Oncol 2024; 7:63-72. [PMID: 37516587 DOI: 10.1016/j.euo.2023.07.004] [Citation(s) in RCA: 11] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2023] [Revised: 06/22/2023] [Accepted: 07/07/2023] [Indexed: 07/31/2023]
Abstract
BACKGROUND Men with high-risk prostate cancer undergoing surgery likely recur due to failure to completely excise regional and/or local disease. OBJECTIVE The first-in-human evaluation of safety, pharmacokinetics, and exploratory efficacy of IS-002, a novel near-infrared prostate-specific membrane antigen (PSMA)-targeted fluorescence imaging agent, designed for intraoperative prostate cancer visualization. DESIGN, SETTING, AND PARTICIPANTS A phase 1, single-center, dose-escalation study was conducted in 24 men with high-risk prostate cancer scheduled for robotic-assisted radical prostatectomy with (extended) pelvic lymph node dissection using the da Vinci surgical system. OUTCOME MEASUREMENTS AND STATISTICAL ANALYSIS Adverse events (AEs), vital signs, complete blood count, complete metabolic panel, urinalysis, and electrocardiogram were assessed over a 14-d period and compared with baseline. The pharmacokinetic profile of IS-002 was determined. Diagnostic accuracy was assessed for exploratory efficacy. RESULTS AND LIMITATIONS AEs predominantly included discoloration of urine (n = 22/24; expected, related, grade 1). There were no grade ≥2 AEs. IS-002 Cmax and area under the curve increased with increasing dose. Plasma concentrations declined rapidly in a biphasic manner, with the median terminal half-lives ranging from 5.0 to 7.6 h, independent of dose and renal function. At 25 μg/kg, the exploratory efficacy readouts for the negative and positive predictive values were, 97% and 45% for lymph nodes, and 100% and 80% for residual/locoregional disease detection, respectively. CONCLUSIONS IS-002 is safe and well tolerated, and has the potential to enable intraoperative tumor detection that could not be identified using standard imaging. PATIENT SUMMARY IS-002 is a new imaging agent that specifically targets the prostate-specific membrane antigen receptor. In this study, we tested IS-002 for the first time in men with high-risk prostate cancer undergoing surgery and found that IS-002 is safe, is cleared from the body quickly, and potentially allows identification of prostate cancer in areas that would not be identified by conventional white light imaging.
Collapse
|
27
|
van der Zee JM, Fitski M, van de Sande MAJ, Buser MAD, Hiep MAJ, Terwisscha van Scheltinga CEJ, Hulsker CCC, van den Bosch CH, van de Ven CP, van der Heijden L, Bökkerink GMJ, Wijnen MHWA, Siepel FJ, van der Steeg AFW. Tracked ultrasound registration for intraoperative navigation during pediatric bone tumor resections with soft tissue components: a porcine cadaver study. Int J Comput Assist Radiol Surg 2024; 19:297-302. [PMID: 37924438 PMCID: PMC10838821 DOI: 10.1007/s11548-023-03021-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2023] [Accepted: 09/12/2023] [Indexed: 11/06/2023]
Abstract
PURPOSE Resection of pediatric osteosarcoma in the extremities with soft tissue involvement presents surgical challenges due to difficult visualization and palpation of the tumor. Therefore, an adequate image-guided surgery (IGS) system is required for more accurate tumor resection. The use of a 3D model in combination with intraoperative tracked ultrasound (iUS) may enhance surgical decision making. This study evaluates the clinical feasibility of iUS as a surgical tool using a porcine cadaver model. METHODS First, a 3D model of the porcine lower limb was created based on preoperative scans. Second, the bone surface of the tibia was automatically detected with an iUS by a sweep on the skin. The bone surface of the preoperative 3D model was then matched with the bone surface detected by the iUS. Ten artificial targets were used to calculate the target registration error (TRE). Intraoperative performance of iUS IGS was evaluated by six pediatric surgeons and two pediatric oncologic orthopedists. Finally, user experience was assessed with a post-procedural questionnaire. RESULTS Eight registration procedures were performed with a mean TRE of 6.78 ± 1.33 mm. The surgeons agreed about the willingness for clinical implementation in their current clinical practice. They mentioned the additional clinical value of iUS in combination with the 3D model for the localization of the soft tissue components of the tumor. The concept of the proposed IGS system is considered feasible by the clinical panel, but the large TRE and degree of automation need to be addressed in further work. CONCLUSION The participating pediatric surgeons and orthopedists were convinced of the clinical value of the interaction between the iUS and the 3D model. Further research is required to improve the surgical accuracy and degree of automation of iUS-based registration systems for the surgical management of pediatric osteosarcoma.
Collapse
|
28
|
Li D, Mao Y, Tu P, Shi H, Sun W, Zhao D, Chen C, Chen X. A robotic system for transthoracic puncture of pulmonary nodules based on gated respiratory compensation. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2024; 244:107995. [PMID: 38157826 DOI: 10.1016/j.cmpb.2023.107995] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/31/2023] [Revised: 12/20/2023] [Accepted: 12/22/2023] [Indexed: 01/03/2024]
Abstract
BACKGROUND AND OBJECTIVE With the urgent demands for rapid and precise localization of pulmonary nodules in procedures such as transthoracic puncture biopsy and thoracoscopic surgery, many surgical navigation and robotic systems are applied in the clinical practice of thoracic operation. However, current available positioning methods have certain limitations, including high radiation exposure, large errors from respiratory, complicated and time-consuming procedures, etc. METHODS: To address these issues, a preoperative computed tomography (CT) image-guided robotic system for transthoracic puncture was proposed in this study. Firstly, an algorithm for puncture path planning based on constraints from clinical knowledge was developed. This algorithm enables the calculation of Pareto optimal solutions for multiple clinical targets concerning puncture angle, puncture length, and distance from hazardous areas. Secondly, to eradicate intraoperative radiation exposure, a fast registration method based on preoperative CT and gated respiration compensation was proposed. The registration process could be completed by the direct selection of points on the skin near the sternum using a hand-held probe. Gating detection and joint optimization algorithms are then performed on the collected point cloud data to compensate for errors from respiratory motion. Thirdly, to enhance accuracy and intraoperative safety, the puncture guide was utilized as an end effector to restrict the movement of the optically tracked needle, then risky actions with patient contact would be strictly limited. RESULTS The proposed system was evaluated through phantom experiments on our custom-designed simulation test platform for patient respiratory motion to assess its accuracy and feasibility. The results demonstrated an average target point error (TPE) of 2.46 ± 0.68 mm and an angle error (AE) of 1.49 ± 0.45° for the robotic system. CONCLUSIONS In conclusion, our proposed system ensures accuracy, surgical efficiency, and safety while also reducing needle insertions and radiation exposure in transthoracic puncture procedures, thus offering substantial potential for clinical application.
Collapse
|
29
|
Feng X, Zhang X, Shi X, Li L, Wang S. ST-ITEF: Spatio-Temporal Intraoperative Task Estimating Framework to recognize surgical phase and predict instrument path based on multi-object tracking in keratoplasty. Med Image Anal 2024; 91:103026. [PMID: 37976868 DOI: 10.1016/j.media.2023.103026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2022] [Revised: 08/22/2023] [Accepted: 11/03/2023] [Indexed: 11/19/2023]
Abstract
Computer-assisted cognition guidance for surgical robotics by computer vision is a potential future outcome, which could facilitate the surgery for both operation accuracy and autonomy level. In this paper, multiple-object segmentation and feature extraction from this segmentation are combined to determine and predict surgical manipulation. A novel three-stage Spatio-Temporal Intraoperative Task Estimating Framework is proposed, with a quantitative expression derived from ophthalmologists' visual information process and also with the multi-object tracking of surgical instruments and human corneas involved in keratoplasty. In the estimation of intraoperative workflow, quantifying the operation parameters is still an open challenge. This problem is tackled by extracting key geometric properties from multi-object segmentation and calculating the relative position among instruments and corneas. A decision framework is further proposed, based on prior geometric properties, to recognize the current surgical phase and predict the instrument path for each phase. Our framework is tested and evaluated by real human keratoplasty videos. The optimized DeepLabV3 with image filtration won the competitive class-IoU in the segmentation task and the mean phase jaccard reached 55.58 % for the phase recognition. Both the qualitative and quantitative results indicate that our framework can achieve accurate segmentation and surgical phase recognition under complex disturbance. The Intraoperative Task Estimating Framework would be highly potential to guide surgical robots in clinical practice.
Collapse
|
30
|
Guo L, Nahm W. A cGAN-based network for depth estimation from bronchoscopic images. Int J Comput Assist Radiol Surg 2024; 19:33-36. [PMID: 37561354 PMCID: PMC10769989 DOI: 10.1007/s11548-023-02978-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2023] [Accepted: 05/24/2023] [Indexed: 08/11/2023]
Abstract
PURPOSE Depth estimation is the basis of 3D reconstruction of airway structure from 2D bronchoscopic scenes, which can be further used to develop a vision-based bronchoscopic navigation system. This work aims to improve the performance of depth estimation directly from bronchoscopic images by training a depth estimation network on both synthetic and real datasets. METHODS We propose a cGAN-based network Bronchoscopic-Depth-GAN (BronchoDep-GAN) to estimate depth from bronchoscopic images by translating bronchoscopic images into depth maps. The network is trained in a supervised way learning from synthetic textured bronchoscopic image-depth pairs and virtual bronchoscopic image-depth pairs, and simultaneously, also in an unsupervised way learning from unpaired real bronchoscopic images and depth maps to adapt the model to real bronchoscopic scenes. RESULTS Our method is tested on both synthetic data and real data. However, the tests on real data are only qualitative, as no ground truth is available. The results show that our network obtains better accuracy in all cases in estimating depth from bronchoscopic images compared to the well-known cGANs pix2pix. CONCLUSIONS Including virtual and real bronchoscopic images in the training phase of the depth estimation networks can improve depth estimation's performance on both synthetic and real scenes. Further validation of this work is planned on 3D clinical phantoms. Based on the depth estimation results obtained in this work, the accuracy of locating bronchoscopes with corresponding pre-operative CTs will also be evaluated in comparison with the current clinical status.
Collapse
|
31
|
Olivetto M, Testelin S. Surgical navigation in maxillofacial surgery: A French national survey. JOURNAL OF STOMATOLOGY, ORAL AND MAXILLOFACIAL SURGERY 2023; 124:101468. [PMID: 37080359 DOI: 10.1016/j.jormas.2023.101468] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/12/2023] [Revised: 04/09/2023] [Accepted: 04/10/2023] [Indexed: 04/22/2023]
Abstract
PURPOSE to gain a national understanding of the utilization of surgical navigation among maxillofacial surgeons in France through a web-based questionnaire. METHODS A 14-point multiple-choice questionnaire was created and distributed to the participants, divided into two sections. The first section gathered general information about the respondents, and the second section provided an overview of the use of surgical navigation. RESULT A total of 75 participants completed the survey. The results showed that a majority of university hospital departments (65%) utilize an intra-operative 3D imaging system, while very few private clinics and general hospitals use this technology. CONCLUSION The survey suggests that surgical navigation is primarily used in university centers in French maxillofacial surgery, with limited utilization and non-standardized indications for use.
Collapse
|
32
|
Ramalhinho J, Yoo S, Dowrick T, Koo B, Somasundaram M, Gurusamy K, Hawkes DJ, Davidson B, Blandford A, Clarkson MJ. The value of Augmented Reality in surgery - A usability study on laparoscopic liver surgery. Med Image Anal 2023; 90:102943. [PMID: 37703675 PMCID: PMC10958137 DOI: 10.1016/j.media.2023.102943] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2022] [Revised: 06/29/2023] [Accepted: 08/24/2023] [Indexed: 09/15/2023]
Abstract
Augmented Reality (AR) is considered to be a promising technology for the guidance of laparoscopic liver surgery. By overlaying pre-operative 3D information of the liver and internal blood vessels on the laparoscopic view, surgeons can better understand the location of critical structures. In an effort to enable AR, several authors have focused on the development of methods to obtain an accurate alignment between the laparoscopic video image and the pre-operative 3D data of the liver, without assessing the benefit that the resulting overlay can provide during surgery. In this paper, we present a study that aims to assess quantitatively and qualitatively the value of an AR overlay in laparoscopic surgery during a simulated surgical task on a phantom setup. We design a study where participants are asked to physically localise pre-operative tumours in a liver phantom using three image guidance conditions - a baseline condition without any image guidance, a condition where the 3D surfaces of the liver are aligned to the video and displayed on a black background, and a condition where video see-through AR is displayed on the laparoscopic video. Using data collected from a cohort of 24 participants which include 12 surgeons, we observe that compared to the baseline, AR decreases the median localisation error of surgeons on non-peripheral targets from 25.8 mm to 9.2 mm. Using subjective feedback, we also identify that AR introduces usability improvements in the surgical task and increases the perceived confidence of the users. Between the two tested displays, the majority of participants preferred to use the AR overlay instead of navigated view of the 3D surfaces on a separate screen. We conclude that AR has the potential to improve performance and decision making in laparoscopic surgery, and that improvements in overlay alignment accuracy and depth perception should be pursued in the future.
Collapse
|
33
|
Sikkenk DJ, Sterkenburg AJ, Burghgraef TA, Akol H, Schwartz MP, Arensman R, Verheijen PM, Nagengast WB, Consten ECJ. Robot-assisted fluorescent sentinel lymph node identification in early-stage colon cancer. Surg Endosc 2023; 37:8394-8403. [PMID: 37721591 PMCID: PMC10615938 DOI: 10.1007/s00464-023-10394-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2023] [Accepted: 08/13/2023] [Indexed: 09/19/2023]
Abstract
BACKGROUND Patients with cT1-2 colon cancer (CC) have a 10-20% risk of lymph node metastases. Sentinel lymph node identification (SLNi) could improve staging and reduce morbidity in future organ-preserving CC surgery. This pilot study aimed to assess safety and feasibility of robot-assisted fluorescence-guided SLNi using submucosally injected indocyanine green (ICG) in patients with cT1-2N0M0 CC. METHODS Ten consecutive patients with cT1-2N0M0 CC were included in this prospective feasibility study. Intraoperative submucosal, peritumoral injection of ICG was performed during a colonoscopy. Subsequently, the near-infrared fluorescence 'Firefly' mode of the da Vinci Xi robotic surgical system was used for SLNi. SLNs were marked with a suture, after which a segmental colectomy was performed. The SLN was postoperatively ultrastaged using serial slicing and immunohistochemistry, in addition to the standard pathological examination of the specimen. Colonoscopy time, detection time (time from ICG injection to first SLNi), and total SLNi time were measured (time from the start of colonoscopy to start of segmental resection). Intraoperative, postoperative, and pathological outcomes were registered. RESULTS In all patients, at least one SLN was identified (mean 2.3 SLNs, SLN diameter range 1-13 mm). No tracer-related adverse events were noted. Median colonoscopy time was 12 min, detection time was 6 min, and total SLNi time was 30.5 min. Two patients had lymph node metastases present in the SLN, and there were no patients with false negative SLNs. No patient was upstaged due to ultrastaging of the SLN after an initial negative standard pathological examination. Half of the patients unexpectedly had pT3 tumours. CONCLUSIONS Robot-assisted fluorescence-guided SLNi using submucosally injected ICG in ten patients with cT1-2N0M0 CC was safe and feasible. SLNi was performed in an acceptable timespan and SLNs down to 1 mm were detected. All lymph node metastases would have been detected if SLN biopsy had been performed.
Collapse
|
34
|
Solbakken AM, Sellevold S, Spasojevic M, Julsrud L, Emblemsvåg HL, Reims HM, Sørensen O, Thorgersen EB, Fauske L, Ågren JSM, Brennhovd B, Ryder T, Larsen SG, Flatmark K. Navigation-Assisted Surgery for Locally Advanced Primary and Recurrent Rectal Cancer. Ann Surg Oncol 2023; 30:7602-7611. [PMID: 37481493 PMCID: PMC10562504 DOI: 10.1245/s10434-023-13964-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2023] [Accepted: 07/03/2023] [Indexed: 07/24/2023]
Abstract
BACKGROUND In some surgical disciplines, navigation-assisted surgery has become standard of care, but in rectal cancer, indications for navigation and the utility of different technologies remain undetermined. METHODS The NAVI-LARRC prospective study (NCT04512937; IDEAL Stage 2a) evaluated feasibility of navigation in patients with locally advanced primary (LARC) and recurrent rectal cancer (LRRC). Included patients had advanced tumours with high risk of incomplete (R1/R2) resection, and navigation was considered likely to improve the probability of complete resection (R0). Tumours were classified according to pelvic compartmental involvement, as suggested by the Royal Marsden group. The BrainlabTM navigation platform was used for preoperative segmentation of tumour and pelvic anatomy, and for intraoperative navigation with optical tracking. R0 resection rates, surgeons' experiences, and adherence to the preoperative resection plan were assessed. RESULTS Seventeen patients with tumours involving the posterior/lateral compartments underwent navigation-assisted procedures. Fifteen patients required abdominosacral resection, and 3 had resection of the sciatic nerve. R0 resection was obtained in 6/8 (75%) LARC and 6/9 (69%) LRRC cases. Preoperative segmentation was time-consuming (median 3.5 h), but intraoperative navigation was accurate. Surgeons reported navigation to be feasible, and adherence to the resection plan was satisfactory. CONCLUSIONS Navigation-assisted surgery using optical tracking was feasible. The preoperative planning was time-consuming, but intraoperative navigation was accurate and resulted in acceptable R0 resection rates. Selected patients are likely to benefit from navigation-assisted surgery.
Collapse
|
35
|
Bedoya MA, Krokhmal AA, Kourmouzi VC, Kwatra NS, Drubach LA, Fehnel KP, Proctor MR, Voss SD. Use of intraoperative bone scintigraphy for resection of spinal osteoid osteoma. Pediatr Radiol 2023; 53:2424-2433. [PMID: 37740781 DOI: 10.1007/s00247-023-05773-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/08/2023] [Revised: 09/05/2023] [Accepted: 09/07/2023] [Indexed: 09/25/2023]
Abstract
BACKGROUND The location and proximity to the spinal cord in spinal osteoid osteoma can increase the likelihood of an incomplete resection. Intraoperative bone scintigraphy (IOBS) can be used to verify location and complete surgical resection. OBJECTIVE To review our experience using IOBS for resection of intraspinal osteoid osteoma. METHODS IRB approved, retrospective review of IOBS-guided resection over 10 years. Patients underwent injection of 200 uCi/kg (1-20 mCi) 99mTc-MDP 3-4 h prior surgery. Portable single-headed gamma camera equipped with a pinhole collimator (3- or 4-mm aperture) was used. Images were obtained pre-operatively, at the start of the procedure, and intraoperatively. Operative notes were reviewed. Evaluation of recurrence and clinical follow-up was performed. RESULTS Twenty IOBS-guided resections were performed in 18 patients (median age 13.5 years, 6-22 years, 12 males). Size ranged 5-16 mm, with 38.9% (7/18) cervical, 22.2% (4/18) thoracic, 22.2% (4/18) lumbar, and 16.7% (3/18) sacral. In all cases, IOBS was able to localize the lesion. After suspected total excision, IOBS altered the surgical plan in 75% of cases (15/20), showing residual activity prompting further resection. Median length of follow-up was 6 months (range 1-156 months) with 90% (18/20) showing complete resection without recurrence. Two patients had osteoid osteoma recurrence at 7 and 10 months following the original resection, requiring re-intervention. CONCLUSIONS IOBS is a useful tool for real-time localization and assessment of spinal osteoid osteoma resection. In all cases, IOBS was able to localize the lesion and changed surgical planning in 75% of cases. Ninety percent of patients achieved complete resection and remain recurrence free.
Collapse
|
36
|
Wongso H, Kurniawan A, Forentin AM, Susilo VY, Setiadi Y, Mahendra I, Febrian MB, Rosdianto AM, Setiawan I, Goenawan H, Susianti S, Supratman U, Widyasari EM, Wibawa TH, Sriyani ME, Halimah I, Lesmana R. New hybrid radio-fluorescent probes [ 131I]-BPF-01 and [ 131I]-BPF-02 for visualisation of cancer cells: Synthesis and preliminary in vitro and ex vivo evaluations. Heliyon 2023; 9:e20710. [PMID: 37860547 PMCID: PMC10582398 DOI: 10.1016/j.heliyon.2023.e20710] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2023] [Revised: 09/30/2023] [Accepted: 10/04/2023] [Indexed: 10/21/2023] Open
Abstract
We synthesised and biologically evaluated two new hybrid probes [131I]BPF-01 and [131I]BPF-02 which were built from three structural entities: benzothiazole-phenyl, fluorescein isothiocyanate (FITC), and iodine-131. These probes were designed for potential applications in assisting surgical procedures of solid cancers. The cytotoxicity study demonstrated that fluorescent probes BPF-01 (31.23 μg/mL) and BPF-02 (250 μg/mL) were relatively not toxic to normal immortalized human keratinocytes (HaCaT) cells, as indicated by the percentage of cell survival above 50 %. Furthermore, both probes displayed low to moderate anticancer activity against the breast cancer cells (MDA-MB-231) and prostate cancer cells (LNCaP and DU-145). The probe BPF-01 apparently showed an accumulation in the tumour tissues, as suggested by ex vivo fluorescence examinations. In addition, the cellular uptake study suggests that hybrid probe [131I]-BPF-01 was potentially accumulated in the MCF-7 cell line with the highest uptake of 16.11 ± 1.52 % after 2 h of incubation, approximately 50-fold higher than the accumulation of iodine-131 (control). The magnetic bead assay suggests that [131I]-BPF-02 and [131I]-BPF-02 showed a promising capability to interact with translocator protein 18 kDa (TSPO). Moreover, the computational data showed that the binding scores for ligands 7-8, BPF-01 and BPF-02, and [131I]-BPF-01 and [131I]-BPF-02 in the TSPO were considerably high. Accordingly, fluorescent probes BPF-01 and BPF-02, and hybrid probes [131I]BPF-01 and [131I]BPF-02 can be further developed for targeting cancer cells during intraoperative tumour surgery.
Collapse
|
37
|
Heuninck E, Van de Heyning P, Van Rompaey V, Mertens G, Topsakal V. Audiological outcomes of robot-assisted cochlear implant surgery. Eur Arch Otorhinolaryngol 2023; 280:4433-4444. [PMID: 37043021 DOI: 10.1007/s00405-023-07961-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2022] [Accepted: 04/03/2023] [Indexed: 04/13/2023]
Abstract
PURPOSE The main objective of this study is to evaluate the short-term and long-term audiological outcomes in patients who underwent cochlear implantation with a robot-assisted system to enable access to the cochlea, and to compare outcomes with a matched control group of patients who underwent cochlear implantation with conventional access to the cochlea. METHODS In total, 23 patients were implanted by robot-assisted cochlear implant surgery (RACIS). To evaluate the effectiveness of robotic surgery in terms of audiological outcomes, a statistically balanced control group of conventionally implanted patients was created. Minimal outcome measures (MOM), consisting of pure-tone audiometry, speech understanding in quiet and speech understanding in noise were performed pre-operatively and at 3 months, 6 months, 12 months and 2 years post-activation of the audioprocessor. RESULTS There was no statistically significant difference in pure-tone audiometry, speech perception in quiet and speech perception in noise between robotically implanted and conventionally implanted patients pre-operatively, 3 months, 6 months, 12 months and 2 years post-activation. A significant improvement in pure-tone hearing thresholds, speech understanding in quiet and speech understanding in noise with the cochlear implant has been quantified as of the first measurements at 3 months and this significant improvement remained stable over a time period of 2 years for HEARO implanted patients. CONCLUSION Clinical outcomes in robot-assisted cochlear implant surgery are comparable to conventional cochlear implantation. CLINICALTRAILS. GOV TRAIL REGISTRATION NUMBERS NCT03746613 (date of registration: 19/11/2018), NCT04102215 (date of registration: 25/09/2019).
Collapse
|
38
|
Geiger L, Zuniga MG, Lenarz T, Majdani O, Rau TS. Drilling accuracy evaluation of a mouldable surgical targeting system for minimally invasive access to anatomic targets in the temporal bone. Eur Arch Otorhinolaryngol 2023; 280:4371-4379. [PMID: 37010602 PMCID: PMC10477231 DOI: 10.1007/s00405-023-07925-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2022] [Accepted: 03/13/2023] [Indexed: 04/04/2023]
Abstract
PURPOSE Minimally invasive cochlear implant surgery using a micro-stereotactic surgical targeting system with on-site moulding of the template aims for a reliable, less experience-dependent access to the inner ear under maximal reduction of trauma to anatomic structures. We present an accuracy evaluation of our system in ex-vivo testing. METHODS Eleven drilling experiments were performed on four cadaveric temporal bone specimens. The process involved preoperative imaging after affixing the reference frame to the skull, planning of a safe trajectory preserving relevant anatomical structures, customization of the surgical template, execution of the guided drilling and postoperative imaging for determination of the drilling accuracy. Deviation between the drilled and desired trajectories was measured at different depths. RESULTS All drilling experiments were successfully performed. Other than purposely sacrificing the chorda tympani in one experiment, no other relevant anatomy, such as facial nerve, chorda tympani, ossicles or external auditory canal were harmed. Deviation between the desired and achieved path was found to be 0.25 ± 0.16 mm at skulls' surface and 0.51 ± 0.35 mm at the target level. The closest distance of the drilled trajectories' outer circumference to the facial nerve was 0.44 mm. CONCLUSIONS We demonstrated the usability for drilling to the middle ear on human cadaveric specimen in a pre-clinical setting. Accuracy proved to be suitable for many applications such as procedures within the field of image-guided neurosurgery. Promising approaches to reach sufficient submillimetre accuracy for CI surgery have been outlined.
Collapse
|
39
|
Berrens AC, Knipper S, Marra G, van Leeuwen PJ, van der Mierden S, Donswijk ML, Maurer T, van Leeuwen FW, van der Poel HG. State of the Art in Prostate-specific Membrane Antigen-targeted Surgery-A Systematic Review. EUR UROL SUPPL 2023; 54:43-55. [PMID: 37361200 PMCID: PMC10285550 DOI: 10.1016/j.euros.2023.05.014] [Citation(s) in RCA: 21] [Impact Index Per Article: 21.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/21/2023] [Indexed: 06/28/2023] Open
Abstract
Context Identifying malignant tissue and leaving adjacent structures undisturbed constitute an ongoing challenge in prostate cancer (PCa) surgery. Image and radioguided surgical technologies targeting the prostate-specific membrane antigen (PSMA) receptor may facilitate identification and removal of diseased tissue. Objective To perform a systematic review of the clinical studies on PSMA-targeted surgery. Evidence acquisition The MEDLINE (OvidSP), Embase.com, and Cochrane Library databases were searched. Identified reports were critically appraised according to the Idea, Development, Exploration, Assessment, Long-term framework criteria. The risk of bias (RoB) was assessed as per the Risk Of Bias In Non-randomized Studies-of Interventions tool. The strengths and limitations of the techniques and corresponding oncological outcomes were extracted as areas of interest. Data were reported according to the Preferred Reporting Items for Systematic Reviews and Meta-analyses guidelines. Evidence synthesis In total, 29 reports were selected, including eight prospective studies, 12 retrospective analyses, and nine case reports, all with a high or an unclear RoB. In 72.4% of studies, PSMA targeting was achieved via radioguided surgery (RGS), predominantly using 99mTc-PSMA-I&S (66.7%). Hybrid approaches that complement RGS with optical guidance are emerging. The majority of studies retrieved were pilot studies with a short follow-up. In 13 reports, salvage lymph node surgery was discussed (44.8%). In 12 more recent reports (41.4%), PSMA targeting was studied in primary PCa surgery (50.0% lymph nodes and 50.0% surgical margins), and four studied both primary and salvage surgery (13.8%). Overall, specificity was higher than sensitivity (median 98.9% and 84.8%, respectively). Oncological outcomes were discussed only in reports on the use of 99mTc-PSMA-I&S in salvage surgery (median follow-up of 17.2 mo). A decline in prostate-specific antigen level of >90% ranged from 22.0% to 100.0%, and biochemical recurrence ranged from 50.0% to 61.8% of patients. Conclusions In PSMA-targeted surgery, most studies address salvage PSMA-RGS using 99mTc-PSMA-I&S. Available evidence suggests that the specificity of intraoperative PSMA targeting is higher than the sensitivity. The studies that included follow-up did not yet objectify a clear oncological benefit. Lacking solid outcome data, PSMA-targeted surgery remains investigational. Patient summary In this paper, we review recent advances in prostate-specific membrane antigen (PSMA)-targeted surgery, which is used to help identify and remove prostate cancer. We found good evidence to suggest that PSMA targeting helps identify prostate cancer during surgery. The oncological benefits have yet to be investigated further.
Collapse
|
40
|
Mandelka E, Gierse J, Zimmermann F, Gruetzner PA, Franke J, Vetter SY. Implications of navigation in thoracolumbar pedicle screw placement on screw accuracy and screw diameter/pedicle width ratio. BRAIN & SPINE 2023; 3:101780. [PMID: 38020982 PMCID: PMC10668071 DOI: 10.1016/j.bas.2023.101780] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/14/2023] [Revised: 05/22/2023] [Accepted: 07/10/2023] [Indexed: 12/01/2023]
Abstract
Introduction There is ample evidence that higher accuracy can be achieved in thoracolumbar pedicle screw placement by using spinal navigation. Still, to date, the evidence regarding the influence of the use of navigation on the screw diameter to pedicle width ratio remains limited. Research question The aim of this study was to investigate the implications of navigation in thoracolumbar pedicle screw placement not only on screw accuracy, but on the screw diameter to pedicle width ratio as well. Material and methods In this single-center single-surgeon study, 45 Patients undergoing navigated thoracolumbar pedicle screw placement were prospectively included. The results were compared with a matched comparison group of patients in which screw placement was performed under fluoroscopic guidance. The screw accuracy and the screw diameter to pedicle width ratio of every screw were compared between the groups. Results Screw accuracy was significantly higher in the navigation group compared to the fluoroscopic guidance group, alongside with a significant increase of the screw diameter to pedicle width ratio by approximately 10%. In addition, both the intraoperative radiation dose and the operating time tended to be lower in the study group. Conclusion This study was able to show that navigated thoracolumbar pedicle screw placement not only increases the accuracy of screw placement but also facilitates the selection of the adequate screw sizes, which according to the literature has positive effects on fixation strength. Meanwhile, the use of navigation did not negatively affect the time needed for surgery or the patient's intraoperative exposure to radiation.
Collapse
|
41
|
Vreeburg MTA, Azargoshasb S, van Willigen D, Molenaar T, van Oosterom MN, Buckle T, Slof LJ, Klop M, Karakullukcu B, Donswijk M, van der Poel HG, van Leeuwen FWB, Brouwer OR, Rietbergen DDD. Comparison of two hybrid sentinel node tracers: indocyanine green (ICG)- 99mTc-nanocolloid vs. ICG- 99mTc-nanoscan from a nuclear medicine and surgical perspective. Eur J Nucl Med Mol Imaging 2023; 50:2282-2291. [PMID: 36929210 PMCID: PMC10250462 DOI: 10.1007/s00259-023-06157-9] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2022] [Accepted: 02/15/2023] [Indexed: 03/18/2023]
Abstract
BACKGROUND Lymph node (LN) metastasis is a relevant predictor for survival in patients with a.o. penile cancer (PeCa), malignant melanoma. The sentinel node (SN) procedure comprises targeted resection of the first tumour-draining SNs. Here, the hybrid tracer indocyanine green (ICG)-99mTc-nanocolloid has been used for several years to combine optical and nuclear detection. Recently, the resource of the nanocolloid precursor stopped production and the precursor was replaced by a different but chemically comparable colloid, nanoscan. Our aim was to study the performance of ICG-99mTc-nanoscan compared to ICG-99mTc-nanocolloid from a nuclear and surgical perspective. METHODS Twenty-four patients with either PeCa or head-and-neck (H&N) melanoma and scheduled for a SN procedure were included. The initial group (n = 11) received ICG-99mTc-nanocolloid until no longer available; the second group (n = 13) received ICG-99mTc-nanoscan. Tracer uptake was assessed on lymphoscintigraphy and single-photon emission (SPECT). Intraoperatively, SNs were identified using gamma tracing and fluorescence imaging. Ex vivo (back-table) measurements were conducted to quantify the fluorescence emissions. Chemical analysis was performed to compare the ICG assembly on both precursors. RESULTS The mean tracer uptake in the SNs was similar for ICG-99mTc-nanocolloid (2.2 ± 4.3%ID) and ICG-99mTc-nanoscan (1.8 ± 2.6%ID; p = 0.68). 3 SNs (interquartile range (IQR) 3-4) were detected on lymphoscintigraphy in PeCa patients receiving ICG-99mTc-nanoscan compared to 2 SNs (IQR 2-3) in PeCa patients receiving ICG-99mTc-nanocolloid (p = 0.045), no differences were observed in H&N patients. Back-table measurements of resected SNs revealed a lower total fluorescence intensity in the ICG-99mTc-nanoscan group (24*109 arbitrary units (A.U) IQR 1.6*109-14*109 in the ICG-99mTc-nanocolloid group versus 4.6*109 A.U. IQR 2.4*109-42*109 in the ICG-99mTc-nanoscan group, p = 0.0054). This was consistent with a larger degree of "stacked" ICG observed in the nanoscan formulation. No tracer-related adverse events were reported. CONCLUSIONS Based on this retrospective analysis, we can conclude that ICG-99mTc-nanoscan has similar capacity for SN identification as ICG-99mTc-nanocolloid and can safely be implemented in SN procedures.
Collapse
|
42
|
Wit EMK, KleinJan GH, Berrens AC, van Vliet R, van Leeuwen PJ, Buckle T, Donswijk ML, Bekers EM, van Leeuwen FWB, van der Poel HG. A hybrid radioactive and fluorescence approach is more than the sum of its parts; outcome of a phase II randomized sentinel node trial in prostate cancer patients. Eur J Nucl Med Mol Imaging 2023; 50:2861-2871. [PMID: 37036490 DOI: 10.1007/s00259-023-06191-7] [Citation(s) in RCA: 9] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2022] [Accepted: 03/05/2023] [Indexed: 04/11/2023]
Abstract
OBJECTIVE To determine the diagnostic accuracy of the hybrid tracer indocyanine green (ICG)-Technetium-99 m(99mTc)-nanocolloid compared to sequential tracers of 99mTc-nanocolloid and free-ICG in detecting tumor-positive lymph nodes (LN) during primary surgery in prostate cancer (PCa) patients. INTRODUCTION Image-guided surgery strategies can help visualize individual lymphatic drainage patterns and sentinel lymph nodes (SLNs) in PCa patients. For lymphatic mapping radioactive, fluorescent and hybrid tracers are being clinically exploited. In this prospective randomized phase II trial, we made a head-to-head comparison between ICG-99mTc-nanocolloid (hybrid group) and 99mTc-nanocolloid and subsequent free-ICG injection (sequential group). METHODS PCa patients with a >5% risk of lymphatic involvement according to the 2012 Briganti nomogram and planned for prostatectomy were included and randomized (1:1) between ultrasound-guided intraprostatic tracer administration of ICG-99mTc-nanocolloid (n = 69) or 99mTc-nanocolloid (n = 69) 5 h before surgery. Preoperative lymphoscintigraphy and SPECT/CT were performed to define the locations of the SLNs. Additionally, all participants in the sequential group received an injection of free-ICG at time of surgery. Subsequently, all (S)LNs were dissected using fluorescence guidance followed by an extended pelvic lymph node dissection (ePLND). The primary outcome was the total number of surgically removed (S)LNs and tumor-positive (S)LNs. RESULTS The total number of surgically removed (S)LN packages was 701 and 733 in the hybrid and sequential groups, respectively (p = 0.727). The total number of fluorescent LNs retrieved was 310 and 665 nodes in the hybrid and sequential groups, respectively (p < 0.001). However, no statistically significant difference was observed in the corresponding number of tumor-positive nodes among the groups (44 vs. 33; p = 0.470). Consequently, the rate of tumor-positive fluorescent LNs was higher in the hybrid group (7.4%) compared to the sequential group (2.6%; p = 0.002), indicating an enhanced positive predictive value for the hybrid approach. There was no difference in complications within 90 days after surgery (p = 0.78). CONCLUSIONS The hybrid tracer ICG-99mTc-nanocolloid improved the positive predictive value for tumor-bearing LNs while minimizing the number of fluorescent nodes compared to the sequential tracer approach. Consequently, the hybrid tracer ICG-99mTc-nanocolloid enables the most reliable and minimal invasive method for LN staging in PCa patients.
Collapse
|
43
|
Cho SM, Grupp RB, Gomez C, Gupta I, Armand M, Osgood G, Taylor RH, Unberath M. Visualization in 2D/3D registration matters for assuring technology-assisted image-guided surgery. Int J Comput Assist Radiol Surg 2023; 18:1017-1024. [PMID: 37079247 PMCID: PMC10986429 DOI: 10.1007/s11548-023-02888-0] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2023] [Accepted: 03/27/2023] [Indexed: 04/21/2023]
Abstract
PURPOSE Image-guided navigation and surgical robotics are the next frontiers of minimally invasive surgery. Assuring safety in high-stakes clinical environments is critical for their deployment. 2D/3D registration is an essential, enabling algorithm for most of these systems, as it provides spatial alignment of preoperative data with intraoperative images. While these algorithms have been studied widely, there is a need for verification methods to enable human stakeholders to assess and either approve or reject registration results to ensure safe operation. METHODS To address the verification problem from the perspective of human perception, we develop novel visualization paradigms and use a sampling method based on approximate posterior distribution to simulate registration offsets. We then conduct a user study with 22 participants to investigate how different visualization paradigms (Neutral, Attention-Guiding, Correspondence-Suggesting) affect human performance in evaluating the simulated 2D/3D registration results using 12 pelvic fluoroscopy images. RESULTS All three visualization paradigms allow users to perform better than random guessing to differentiate between offsets of varying magnitude. The novel paradigms show better performance than the neutral paradigm when using an absolute threshold to differentiate acceptable and unacceptable registrations (highest accuracy: Correspondence-Suggesting (65.1%), highest F1 score: Attention-Guiding (65.7%)), as well as when using a paradigm-specific threshold for the same discrimination (highest accuracy: Attention-Guiding (70.4%), highest F1 score: Corresponding-Suggesting (65.0%)). CONCLUSION This study demonstrates that visualization paradigms do affect the human-based assessment of 2D/3D registration errors. However, further exploration is needed to understand this effect better and develop more effective methods to assure accuracy. This research serves as a crucial step toward enhanced surgical autonomy and safety assurance in technology-assisted image-guided surgery.
Collapse
|
44
|
Abari J, Heuninck E, Al Saadi M, Topsakal V. True keyhole cochlear implant surgery. Am J Otolaryngol 2023; 44:103926. [PMID: 37229977 DOI: 10.1016/j.amjoto.2023.103926] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2023] [Revised: 04/28/2023] [Accepted: 05/13/2023] [Indexed: 05/27/2023]
Abstract
INTRODUCTION Minimal invasive Robotic Assisted Cochlear Implant Surgery (RACIS) is a keyhole surgery by definition. It is therefore not possible to visualize the electrode array during insertion in the scala tympani. Hitherto, surgeons visualised the round window via the external auditory canal by folding over the tympanic membrane. However, the opening of a tympanomeatal flap is not minimal invasive and is especially in conventional cochlear implantation surgery not even necessary. Here we prove that image guided and robot assisted surgery can also allow correct electrode array insertion without opening the tympanomeatal flap. AIM The aim is to report the first experience of robotic cochlear implantation surgery fully based on image guided surgery and without the opening of a tympanomeatal flap for electrode array insertion. INTERVENTION RACIS with a straight flexible lateral wall electrode. PRIMARY OUTCOME MEASUREMENTS Electrode cochlear insertion depth with RACIS and autonomous inner ear access with full electrode insertion of a flexible lateral wall electrode array. SECONDARY OUTCOME MEASUREMENTS The audiological outcome in terms of mean hearing thresholds. CONCLUSION After a series of 33 cases and after fine-tuning the insertion angles and yet another new version of planning software to depict the round window approach, a new clinical routine for inserting electrodes fully based on image guided surgery without opening a tympanomeatal flap was developed in robotic-assisted cochlear implant surgery.
Collapse
|
45
|
Jeung D, Choi H, Ha HG, Oh SH, Hong J. Intraoperative zoom lens calibration for high magnification surgical microscope. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2023; 238:107618. [PMID: 37247472 DOI: 10.1016/j.cmpb.2023.107618] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/07/2022] [Revised: 01/25/2023] [Accepted: 05/18/2023] [Indexed: 05/31/2023]
Abstract
BACKGROUND AND OBJECTIVES An augmented reality (AR)-based surgical guidance system is often used with high-magnification zoom lens systems such as a surgical microscope, particularly in neurology or otolaryngology. To superimpose the internal structures of relevant organs on the microscopy image, an accurate calibration process to obtain the camera intrinsic and hand-eye parameters of the microscope is essential. However, conventional calibration methods are unsuitable for surgical microscopes because of their narrow depth of focus at high magnifications. To realize AR-based surgical guidance with a high-magnification surgical microscope, we herein propose a new calibration method that is applicable to the highest magnification levels as well as low magnifications. METHODS The key idea of the proposed method is to find the relationship between the focal length and the hand-eye parameters, which remains constant regardless of the magnification level. Based on this, even if the magnification changes arbitrarily during surgery, the intrinsic and hand-eye parameters are recalculated quickly and accurately with one or two pictures of the pattern. We also developed a dedicated calibration tool with a prism to take focused pattern images without interfering with the surgery. RESULTS The proposed calibration method ensured an AR error of < 1 mm for all magnification levels. In addition, the variation of focal length was within 1% regardless of the magnification level, and the corresponding variation with the conventional calibration method exceeded 20% at high magnification levels. CONCLUSIONS The comparative study showed that the proposed method has outstanding accuracy and reproducibility for a high-magnification surgical microscope. The proposed calibration method is applicable to various endoscope or microscope systems with zoom lens.
Collapse
|
46
|
Bortot B, Mangogna A, Di Lorenzo G, Stabile G, Ricci G, Biffi S. Image-guided cancer surgery: a narrative review on imaging modalities and emerging nanotechnology strategies. J Nanobiotechnology 2023; 21:155. [PMID: 37202750 DOI: 10.1186/s12951-023-01926-y] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2023] [Accepted: 05/11/2023] [Indexed: 05/20/2023] Open
Abstract
Surgical resection is the cornerstone of solid tumour treatment. Current techniques for evaluating margin statuses, such as frozen section, imprint cytology, and intraoperative ultrasound, are helpful. However, an intraoperative assessment of tumour margins that is accurate and safe is clinically necessary. Positive surgical margins (PSM) have a well-documented negative effect on treatment outcomes and survival. As a result, surgical tumour imaging methods are now a practical method for reducing PSM rates and improving the efficiency of debulking surgery. Because of their unique characteristics, nanoparticles can function as contrast agents in image-guided surgery. While most image-guided surgical applications utilizing nanotechnology are now in the preclinical stage, some are beginning to reach the clinical phase. Here, we list the various imaging techniques used in image-guided surgery, such as optical imaging, ultrasound, computed tomography, magnetic resonance imaging, nuclear medicine imaging, and the most current developments in the potential of nanotechnology to detect surgical malignancies. In the coming years, we will see the evolution of nanoparticles tailored to specific tumour types and the introduction of surgical equipment to improve resection accuracy. Although the promise of nanotechnology for producing exogenous molecular contrast agents has been clearly demonstrated, much work remains to be done to put it into practice.
Collapse
|
47
|
Liu J, Xu Z, Meng C, Wusiman S, Xie X, Wang Y, Xiao F, Gu C, Chen J, Ling CC, Li P, Yuan Z, Ling Y. Acidic tumor microenvironment-activatable fluorescent diagnostic probe for the rapid identification and resection of human tumors via spraying. Biosens Bioelectron 2023; 234:115343. [PMID: 37167656 DOI: 10.1016/j.bios.2023.115343] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2023] [Revised: 04/16/2023] [Accepted: 04/20/2023] [Indexed: 05/13/2023]
Abstract
A fluorescent diagnostic probe for real-time intraoperative image-guided tumor resection can significantly improve the efficiency and quality of oncological therapy, but their development is challenging. Herein, a novel fluorescent diagnostic probe called HLTC based on β-carboline was designed and synthesized. HLTC was found to show a ∼10-fold enhancement of fluorescence quantum field with pH from 7.4 to 4.0, indicating its imaging potential in acid environment which is a typical hallmark of the tumor microenvironment (TME). Following fluorescence microscopy imaging showed HLTC could emit specific signals in cancer cells and sections, by both one-photon excitation and two-photon excitation. Importantly, HLTC enabled the precise and rapid delineation of both transplanted tumor and clinical tumor tissues within several minutes of simple topical spray. The tumor-to-background ratio (TBR) was up to 10.2 ± 1.0 at clinical liver cancer tissues and 9.9 ± 0.3 at clinical colon cancer tissues, allowing precise tumor margin identification and the effective guidance of surgical tumor resection. Furthermore, CCK8 assay, pharmacokinetic evaluation, blood analysis and H&E staining were performed, which verified high biocompatibility and biosafety of HLTC at working concentration. These results reveal the exciting potential of this small-molecule fluorescent diagnostic probe for real-time fluorescence-based navigation during surgical tumor resection.
Collapse
|
48
|
Judge JM, Popovic K, Petroni GR, Kross B, McKisson J, McKisson J, Weisenberger AG, Stolin A, Majewski S, Rehm P, Slingluff CL, Williams MB, Dengel LT. Evaluation of Preoperative and Intraoperative Mobile Gamma Camera Imaging in Sentinel Lymph Node Biopsy for Melanoma Independent of Preoperative Lymphoscintigraphy. J Surg Res 2023; 285:176-186. [PMID: 36682343 PMCID: PMC11283632 DOI: 10.1016/j.jss.2022.12.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2022] [Revised: 12/14/2022] [Accepted: 12/17/2022] [Indexed: 01/21/2023]
Abstract
INTRODUCTION Sentinel lymph node biopsy (SLNB) is a standard practice for staging cutaneous melanoma. High false-negative rates have an increased interest in adjunctive techniques for localizing SLNs. Mobile gamma cameras (MGCs) represent potential tools to enhance SLNB performance. METHODS An institutional review board approval was obtained for this study (ClinicalTrials.gov ID NCT01531608). After obtaining informed consent, 20 eligible melanoma patients underwent 99mTc sulfur colloid injection and standard lymphoscintigraphy with a fixed gamma camera (FGC). A survey using a 20 cm square MGC, performed immediately preoperatively by the study surgeon, was used to establish an operative plan while blinded to the FGC results. Subsequently, SLNB was performed using a gamma probe and a novel 6 cm diameter handheld MGC. RESULTS A total of 24 SLN basins were detected by FGC. Prior to unblinding, all 24 basins were identified with the preoperative MGC and the operative plan established by preoperative MGC imaging was confirmed accurate by review of the FGC images. All individual sentinel lymph nodes were identified during intraoperative MGC imaging, and in 5/24 (21%) cases, surgeon-reported additional clinically useful information was obtained from the MGC. CONCLUSIONS Preoperative MGC images provide information consistent with FGC images for planning SLNB and in some cases provide additional information that aided in surgical decision-making.
Collapse
|
49
|
Cannon PC, Ferguson JM, Pitt EB, Shrand JA, Setia SA, Nimmagadda N, Barth EJ, Kavoussi NL, Galloway RL, Herrell SD, Webster RJ. A Safe Framework for Quantitative In Vivo Human Evaluation of Image Guidance. IEEE OPEN JOURNAL OF ENGINEERING IN MEDICINE AND BIOLOGY 2023; 5:133-139. [PMID: 38487093 PMCID: PMC10939321 DOI: 10.1109/ojemb.2023.3271853] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2022] [Revised: 02/16/2023] [Accepted: 03/27/2023] [Indexed: 03/17/2024] Open
Abstract
Goal: We present a new framework for in vivo image guidance evaluation and provide a case study on robotic partial nephrectomy. Methods: This framework (called the "bystander protocol") involves two surgeons, one who solely performs the therapeutic process without image guidance, and another who solely periodically collects data to evaluate image guidance. This isolates the evaluation from the therapy, so that in-development image guidance systems can be tested without risk of negatively impacting the standard of care. We provide a case study applying this protocol in clinical cases during robotic partial nephrectomy surgery. Results: The bystander protocol was performed successfully in 6 patient cases. We find average lesion centroid localization error with our IGS system to be 6.5 mm in vivo compared to our prior result of 3.0 mm in phantoms. Conclusions: The bystander protocol is a safe, effective method for testing in-development image guidance systems in human subjects.
Collapse
|
50
|
Banach A, Naito M, King F, Masaki F, Tsukada H, Hata N. Computer-based airway stenosis quantification from bronchoscopic images: preliminary results from a feasibility trial. Int J Comput Assist Radiol Surg 2023; 18:707-713. [PMID: 36528684 DOI: 10.1007/s11548-022-02808-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2022] [Accepted: 12/06/2022] [Indexed: 12/23/2022]
Abstract
PURPOSE Airway Stenosis (AS) is a condition of airway narrowing in the expiration phase. Bronchoscopy is a minimally invasive pulmonary procedure used to diagnose and/or treat AS. The AS quantification in a form of the Stenosis Index (SI), whether subjective or digital, is necessary for the physician to decide on the most appropriate form of treatment. The literature reports that the subjective SI estimation is inaccurate. In this paper, we propose an approach to quantify the SI defining the level of airway narrowing, using depth estimation from a bronchoscopic image. METHODS In this approach we combined a generative depth estimation technique combined with depth thresholding to provide Computer-based AS quantification. We performed an interim clinical analysis by comparing AS quantification performance of three expert bronchoscopists against the proposed Computer-based method on seven patient datasets. RESULTS The Mean Absolute Error of the subjective Human-based and the proposed Computer-based SI estimation was [Formula: see text] [%] and [Formula: see text] [%], respectively. The correlation coefficients between the CT measurements were used as the gold standard, and the Human-based and Computer-based SI estimation were [Formula: see text] and 0.46, respectively. CONCLUSIONS We presented a new computer method to quantify the severity of AS in bronchoscopy using depth estimation and compared the performance of the method against a human-based approach. The obtained results suggest that the proposed Computer-based AS quantification is a feasible tool that has the potential to provide significant assistance to physicians in bronchoscopy.
Collapse
|