26
|
Eichel VM, Jabs JM, Unser S, Mutters NT, Scherrer M. Does the Reprocessing of Endoscopes Have to Take Place Immediately after Pre-Cleaning? A First Evaluation. Clin Endosc 2021; 54:526-533. [PMID: 34256556 PMCID: PMC8357578 DOI: 10.5946/ce.2020.238] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/27/2020] [Accepted: 01/10/2021] [Indexed: 01/17/2023] Open
Abstract
Background/Aims The recommendations on the time interval between pre-cleaning and reprocessing of endoscopes differ in international guidelines, with a low level of evidence. The aim of this study was to investigate the influence of postponing reprocessing on the reprocessing quality after pre-cleaning the flexible endoscopes.
Methods We reprocessed 124 standardized test tubes simulating endoscope channels after soiling and contamination and determined the reprocessing performance. In addition, we examined contaminated gastroscopes, colonoscopes, and bronchoscopes. The duration of interim storage after pre-cleaning was 16 h for 100 test tubes and up to 24 h for 18 endoscopes. We determined the residual protein content and germ load as markers for cleaning and disinfection performance. In addition, we determined biofilm formation by photometry of crystal violet staining.
Results All test tubes and flexible endoscopes showed residual protein content and germ load significantly below legally prescribed threshold values, independent of the interval between pre-cleaning and reprocessing.
Conclusions Our findings indicate that flexible endoscopes could be stored overnight after pre-cleaning without any influence on the quality of reprocessing. While ensuring patient safety, this could simplify logistical processes and enable cost savings.
Collapse
|
27
|
Suresh S, Pande M, Patel K, Mahometano LD, Romero LG, Barringer D, Sealock RJ, Raju GS. Education, training, and knowledge of infection control among endoscopy technicians and nurses. Am J Infect Control 2021; 49:836-839. [PMID: 33485921 DOI: 10.1016/j.ajic.2021.01.010] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2020] [Revised: 01/14/2021] [Accepted: 01/15/2021] [Indexed: 11/28/2022]
Abstract
Our survey of 88 endoscopy technicians and nurses to determine their experience, training, and knowledge of infection control found that few personnel (<15%) received formal training in endoscope reprocessing or infection prevention before or after joining an endoscopy unit. While self-reported confidence in endoscope reprocessing was high (9 out of 10), knowledge of best practices in this regard lagged (average assessment score of 62%).
Collapse
|
28
|
Antonopoulos I, Faraca G, Tonini D. Recycling of post-consumer plastic packaging waste in the EU: Recovery rates, material flows, and barriers. WASTE MANAGEMENT (NEW YORK, N.Y.) 2021; 126:694-705. [PMID: 33887695 PMCID: PMC8162419 DOI: 10.1016/j.wasman.2021.04.002] [Citation(s) in RCA: 44] [Impact Index Per Article: 14.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/09/2020] [Revised: 01/13/2021] [Accepted: 04/01/2021] [Indexed: 05/15/2023]
Abstract
Increasing plastic waste recycling is a milestone of European environmental policy to reduce environmental impacts and dependency on foreign resources. This is particularly challenging for plastic packaging waste, consisting of very heterogeneous fractions and typically rather contaminated. In this study, we collected primary data from plants sorting and recycling plastic packaging waste to illustrate process efficiencies, material flows, and barriers. We observed that significant losses of target materials occurred both at sorting and recycling stages. These were higher for polymers such as films, polypropylene and polystyrene, and lower for polyethylene terephthalate and high-density polyethylene. Applying material flow analysis, we estimated an overall end-of-life recycling rate for post-consumer plastic packaging waste in EU27 in 2017 of 14% (not considering waste exported as recycled; 25% otherwise). An improved scenario for 2030 showed that achieving an overall end-of-life recycling rate of about 49% was possible when best available practices and technologies were implemented. To fulfil the ambitious recycling targets set at EU27 level (55% overall recycling rate), substantial improvements are necessary at the plants, product design, collection system, and market level. Our findings further indicate that films and other problematic contaminants in the input-waste considerably hamper the recovery rates, thus the improvement of the efficiency of the collection systems is imperative. In parallel, the development of markets for lower value fractions, e.g. polypropylene, could be a way forward to increase recycling, while improvements in the product design will considerably reduce the presence of impurities and contaminants in the input-waste.
Collapse
|
29
|
Lieu A, Mah J, Zanichelli V, Exantus RC, Longtin Y. Impact of extended use and decontamination with vaporized hydrogen peroxide on N95 respirator fit. Am J Infect Control 2020; 48:1457-1461. [PMID: 32805321 PMCID: PMC7428459 DOI: 10.1016/j.ajic.2020.08.010] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2020] [Revised: 08/05/2020] [Accepted: 08/06/2020] [Indexed: 11/09/2022]
Abstract
Background To address the shortage of N95 respirators in the wake of the COVID-19 pandemic, some organizations have recommended the decontamination of respirators using vaporized hydrogen peroxide (VHP) sterilizer for up to 10 times. However, these recommendations are based on studies that did not take into account the extended use of respirators, which can degrade respirator fit. Methods We investigated the impact of extended use and decontamination with VHP on N95 Respirator Fit. We performed a prospective cohort study to determine the number of times respirators can be decontaminated before respirator fit test failure. The primary outcome was the overall number of cycles required for half of the respirators to fail (either mechanical failure or fit test failure). Results Thirty-six participants completed 360 hours of respirator usage across 90 cycles. The median number of cycles completed by participants before respirator failure was 2. The overall number of cycles required for half of respirators to fail was 1, 3, 5, and 4 for the 3M 1860(S), 3M 1870+, Moldex 151X and ProGear 88020 respirators, respectively. Conclusions The combination of prolonged usage and VHP decontamination was associated with early failure. Decontamination and prolonged usage of respirators must be done cautiously.
Collapse
|
30
|
Aljabo A, Mueller E, Abdul-Azeez D, Hoare T, Jain A. Gravity steam reprocessing in healthcare facilities for the reuse of N95 respirators. J Hosp Infect 2020; 106:698-708. [PMID: 33017616 PMCID: PMC7530561 DOI: 10.1016/j.jhin.2020.09.032] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2020] [Revised: 09/17/2020] [Accepted: 09/27/2020] [Indexed: 02/02/2023]
Abstract
BACKGROUND Coronavirus disease 2019 (COVID-19) has significantly impacted the health of millions of people around the world. The shortage of personal protective equipment, including N95 respirators, in hospital facilities has put frontline healthcare professionals at high risk for contracting this virus. AIM To develop a reproducible and safe N95 respirator reprocessing method that satisfies all presented regulatory standards and that can be directly implemented by hospitals using existing available equipment. METHODS A non-toxic gravity steam reprocessing method has been developed for the reuse of N95 respirators consisting of 30 min of steam treatment at 121°C followed by 30 min of heat drying. Samples of model number 1860, 1860s, 1870+, and 9105 N95 respirators were either collected from hospitals (for microbiology testing) or purchased new (for functionality testing), with all functionality tests (i.e. filter efficiency, fit evaluation, and strap integrity) performed at the Centers for Disease Control and Prevention using standard procedures established by the National Institute for Occupational Safety and Health. FINDINGS All tested models passed the minimum filter efficiency of 95% after three cycles of gravity steam reprocessing. The 1870+ N95 respirator model is the most promising model for reprocessing based on its efficient bacterial inactivation coupled with the maintenance of all other key functional respirator properties after multiple reprocessing steps. CONCLUSIONS The gravity steam method can effectively reprocess N95 respirators over at least three reprocessing cycles without negatively impacting the functionality requirements set out by regulators. Enabling the reuse of N95 respirators is a crucial tool for managing both the current pandemic and future healthcare crises.
Collapse
|
31
|
Pinder P, Thomzig A, Schulz-Schaeffer WJ, Beekes M. Alpha-synuclein seeds of Parkinson's disease show high prion-exceeding resistance to steam sterilization. J Hosp Infect 2020; 108:25-32. [PMID: 33137444 DOI: 10.1016/j.jhin.2020.10.018] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2020] [Revised: 10/22/2020] [Accepted: 10/26/2020] [Indexed: 10/23/2022]
Abstract
BACKGROUND Cerebral deposition of abnormally misfolded and aggregated alpha-synuclein (αSyn) is a neuropathological hallmark of Parkinson's disease (PD). Pathologically aggregated αSyn species of PD (αSynPD) can act, in a 'prion-like' manner, as proteinaceous nuclei ('seeds') which are capable of self-templated propagation. This has raised concerns that αSynPD seeds transmitted iatrogenically between humans may stimulate αSyn pathologies or clinically harmful effects in the recipients. Effective decontamination when reprocessing medical devices could significantly counteract such risks. Steam sterilization at 134°C is recommended as an essential pathogen inactivation step in many reprocessing guidelines for medical devices, and also shows effectiveness against prions, the self-propagating biological agents long thought to exhibit the highest resistance to steam sterilization. METHODS This study examined the reduction in αSynPD seeding activity in brain tissue homogenates from patients with PD after steam sterilization at 134°C using a specifically adapted real-time quaking induced conversion assay. FINDINGS Titres of approximately 1010 50% seeding doses per gram were detected in non-steam-sterilized caudate nucleus tissue of patients with PD by endpoint titration. Five minutes of steam sterilization reduced this titre by only 2.25 ± 0.15 decadic-logarithmic units, with an extension of the sterilization time to 90 min not causing additional inactivation. These findings reveal that αSynPD species are disease-associated biological agents with seeding activity that has higher resistance to steam sterilization than prions. CONCLUSION The remarkable heat resistance of αSynPD seeds calls for thoroughly validated cleaning and disinfection methods that reliably remove or inactivate possible contaminations of seeding-active αSyn aggregates when reprocessing medical devices.
Collapse
|
32
|
Panta G, Richardson AK, Shaw IC, Coope PA. Compliance of primary and secondary care public hospitals with standard practices for reprocessing and steam sterilization of reusable medical devices in Nepal: findings from nation-wide multicenter clustered audits. BMC Health Serv Res 2020; 20:923. [PMID: 33028325 PMCID: PMC7542764 DOI: 10.1186/s12913-020-05788-0] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2020] [Accepted: 09/30/2020] [Indexed: 12/24/2022] Open
Abstract
BACKGROUND Reusable medical devices in healthcare facilities are decontaminated and reprocessed following standard practices before each clinical procedure. Reprocessing of critical medical devices (those used for invasive clinical procedures) comprises several processes including sterilization, which provides the highest level of decontamination. Steam sterilization is the most used sterilization procedure across the globe. Noncompliance with standards addressing reprocessing of medical devices may lead to inadequate sterilization and thus increase the risk of person-to-person or environmental transmission of pathogens in healthcare facilities. We conducted nationwide multicenter clustered audits to understand the compliance of primary- and secondary-care public hospitals in Nepal with the standard practices for medical device reprocessing, including steam sterilization. METHODS We developed an audit tool to assess compliance of hospitals with the standard practices for medical device reprocessing including steam sterilization. Altogether, 189 medical device reprocessing cycles which included steam sterilization were assessed in 13 primary and secondary care public hospitals in Nepal using the audit tool. Percentage compliance was calculated for each standard practice. Mean percentage compliances were obtained for overall primary and secondary care hospitals and for each hospital type, specific hospital and process involved. RESULTS For all primary and secondary care hospitals in Nepal, the mean percentage compliance with the standard practices for medical device reprocessing including steam sterilization was 25.9% (95% CI 21.0-30.8%). The lower the level of care provided by the hospitals, the lower was the mean percentage compliance, and the difference in the means across the hospital types was statistically significant (p < 0.01). The mean percentage compliance of individual hospitals ranged from 14.7 to 46.0%. The hospitals had better compliance with the practices for cleaning of used devices and transport and storage of sterilized devices compared with the practices for other processes of the medical device reprocessing cycle. CONCLUSION The primary and secondary care hospitals in Nepal had poor compliance with the standard practices for steam sterilization and reprocessing of medical devices. Interventions to improve compliance of the hospitals are immediately required to minimize the risks of person-to-person or environmental transmission of pathogens through inadequately reprocessed medical devices.
Collapse
|
33
|
Vitale DS, Kwok KK, Liu QY. Society Guidelines-Where Is the Consensus? Gastrointest Endosc Clin N Am 2020; 30:763-779. [PMID: 32891231 DOI: 10.1016/j.giec.2020.06.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
With reports of ongoing duodenoscope contamination and pathogen transmission despite strict adherence to manufacturer reprocessing instructions, professional societies continue to release updated recommendations. Despite general guideline similarities, there are differences. Although adherence to guidelines does not entirely eliminate pathogen contamination or transmission, it is critical to strictly adhere to updated guidelines for maximum risk reduction. In the United States, the Food and Drug Administration and Centers for Disease Control and Prevention continue to offer updates regarding improved duodenoscope reprocessing techniques and endoscope design. This article critically analyzes currently available national and international duodenoscope reprocessing guidelines.
Collapse
|
34
|
Haugen SP, Ferriter A, Connell J, Min LJ, Wiyor HD, Cole S. Recent Actions by the US Food and Drug Administration: Reducing the Risk of Infection from Reprocessed Duodenoscopes. Gastrointest Endosc Clin N Am 2020; 30:711-721. [PMID: 32891227 DOI: 10.1016/j.giec.2020.06.010] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
In addition to technological advancements, engagement and collaboration among the wider community of stakeholders will be beneficial toward reducing the risk of infection from reprocessed duodenoscopes. Such a community can raise awareness of the importance of duodenoscope cleaning, work to improve reprocessing training, identify the most pressing unanswered questions that merit further research, and develop tools that can be used by health care facilities to improve the quality of reprocessing at their sites. The Food and Drug Administration looks forward to working with the community to further reduce the risk of infections from reprocessed duodenoscopes.
Collapse
|
35
|
High-level disinfection of re-usable neonatal resuscitation equipment through boiling and steaming. J Hosp Infect 2020; 106:721-725. [PMID: 32956788 DOI: 10.1016/j.jhin.2020.09.014] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2020] [Accepted: 09/10/2020] [Indexed: 11/21/2022]
Abstract
Infection and asphyxia are two major causes of neonatal death globally. Where single-use resuscitation devices or sterilization of re-usable devices are unavailable, there is a need for effective, low-cost methods of high-level disinfection. Laboratory validation examined the efficacy of boiling and enclosed steaming (without pressure) as methods for attaining high-level disinfection of re-usable neonatal resuscitation equipment. The microbial load extracted and measured for each test article met internationally accepted standards for high-level disinfection. Boiling and steaming are low-cost, effective methods for reprocessing re-usable neonatal resuscitation devices in low- and middle-income countries.
Collapse
|
36
|
Chivukula SR, Lammers S, Wagner J. Assessing organic material on single-use vessel sealing devices: a comparative study of reprocessed and new LigaSure™ devices. Surg Endosc 2020; 35:4539-4549. [PMID: 32909208 PMCID: PMC8263541 DOI: 10.1007/s00464-020-07969-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2020] [Accepted: 08/27/2020] [Indexed: 11/29/2022]
Abstract
Background Reprocessed devices must be thoroughly cleaned prior to sterilization to ensure efficacy of sterilization agents. Many single-use devices are not designed to be thoroughly cleaned. Interlocking design features inherent to LigaSure™ vessel sealing devices may prevent thorough cleaning and promote accumulation of human tissue that cannot be removed. Thus, the aim of this study was to compare industry reprocessed and new LigaSure™ vessel sealing devices for organic material. Methods A total of 168, 84 new and 84 reprocessed, vessel sealing devices were disassembled and inspected for the presence of residual organic matter using visual, microscopic, and chemical analysis. Devices were randomized and test conductors blinded to group membership. Devices were aseptically disassembled and sent through visual inspection. Next, devices were either examined using light microscopy, scanning electron microscopy (SEM) or exposed to a solution that luminesces in the presence of hemoglobin. Additionally, 165 reprocessed devices were sent to a 3rd party lab for sterility testing via direct immersion culture for 14 days. Results Significant amounts of remnant organic material (C, N, O, S, Na, P) were observed with 81/84 reprocessed and 0/84 new devices failing inspection protocols. When tested for the presence of hemoglobin, only 1/12 reprocessed devices passed inspection. SEM of reprocessed devices revealed residues with liquid patterns and diffuse soiling with foreign material. Sterility testing of reprocessed devices revealed a sterility level < 6–3. Conclusions The abundance of material resembling human tissue observed on reprocessed VSDs suggests inadequate cleaning prior to sterilization. Atomic and morphological analyses of the remnant materials suggest that bacterial biofilms could also be present. Additionally, surface degradation and release of reinforcing glass fibers from the device were observed. Devices designed for single use can harbor significant amounts of remnant material that likely interfere with the sterilization process.
Collapse
|
37
|
Pascoe MJ, Robertson A, Crayford A, Durand E, Steer J, Castelli A, Wesgate R, Evans SL, Porch A, Maillard JY. Dry heat and microwave-generated steam protocols for the rapid decontamination of respiratory personal protective equipment in response to COVID-19-related shortages. J Hosp Infect 2020; 106:10-19. [PMID: 32652212 PMCID: PMC7343662 DOI: 10.1016/j.jhin.2020.07.008] [Citation(s) in RCA: 42] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2020] [Accepted: 07/06/2020] [Indexed: 11/23/2022]
Abstract
BACKGROUND In the wake of the SARS-CoV-2 pandemic and unprecedented global demand, clinicians are struggling to source adequate access to personal protective equipment. Respirators can be in short supply, though are necessary to protect workers from SARS-CoV-2 exposure. Rapid decontamination and reuse of respirators may provide relief for the strained procurement situation. METHOD In this study, we investigated the suitability of 70°C dry heat and microwave-generated steam (MGS) for reprocessing of FFP2/N95-type respirators, and Type-II surgical face masks. Staphylococcus aureus was used as a surrogate as it is less susceptible than enveloped viruses to chemical and physical processes. RESULTS We observed >4 log10 reductions in the viability of dry S. aureus treated by dry heat for 90 min at 70°C and >6 log10 reductions by MGS for 90 s. After 3 reprocessing cycles, neither process was found to negatively impact the bacterial or NaCl filtration efficiency of the respirators that were tested. However, MGS was incompatible with Type-II surgical masks tested, as we confirmed that bacterial filtration capacity was completely lost following reprocessing. MGS was observed to be incompatible with some respirator types due to arcing observed around some types of metal nose clips and by loss of adhesion of clips to the mask. CONCLUSION Considering the advantages and disadvantages of each approach, we propose a reprocessing personal protective equipment/face mask workflow for use in medical areas.
Collapse
|
38
|
Oliveira DC, Bonfim F, Vinhas M, Silva I, Teixeira M, Galembeck A. Catheter Reprocessing for Coronary Angiography: It is Not Safe. Cardiol Res 2020; 11:342-347. [PMID: 32849970 PMCID: PMC7430894 DOI: 10.14740/cr1134] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2020] [Accepted: 07/28/2020] [Indexed: 11/24/2022] Open
Abstract
Background Coronary angiography and percutaneous coronary intervention are frequently and increasingly performed worldwide. Although catheters for coronary angiography are considered as single-use devices, some people still question this decision. This study evaluated the structural characteristics and thermal stability of new and reprocessed catheters. Methods Five catheters (Judkins left) of the same brand and manufacturer were selected for each analysis. We evaluated: new catheters, catheters reprocessed once (first), twice (second), thrice (third), and seven times (seventh). The optical analyses of the proximal, middle and distal parts of the catheters were performed by magnifying glass. Besides, thermogravimetric analyses were done. Results After reprocessing, the crushing, color changes, folds, dents, deformations, and lumen narrowing were observed; the stainless-steel framework, the external tortuosity, the interlaced mesh of stainless-steel wires and loss of polymeric material were visualized. Thermogravimetric analysis showed lost of mass of the catheters. Conclusions This study demonstrated that the structural integrity and mass of catheters are lost with reprocessing. These findings may be caused by several steps of reprocessing; however, regardless of which step or steps were responsible, the presence of structural integrity loss leads to the recommendation of not reusing this type of device.
Collapse
|
39
|
Ridtitid W, Pakvisal P, Chatsuwan T, Kerr SJ, Piyachaturawat P, Luangsukrerk T, Kongkam P, Rerknimitr R. Performance characteristics and optimal cut-off value of triple adenylate nucleotides test versus adenosine triphosphate test as point-of-care testing for predicting inadequacy of duodenoscope reprocessing. J Hosp Infect 2020; 106:348-356. [PMID: 32768608 DOI: 10.1016/j.jhin.2020.07.038] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2020] [Accepted: 07/31/2020] [Indexed: 10/23/2022]
Abstract
BACKGROUND Adenosine triphosphate (ATP) test based on one nucleotide has been applied as point-of-care testing (POCT) for bacterial contamination in the medical and food industries. Hypothetically, testing three adenylate nucleotides (A3) may provide better detection of duodenoscope bacterial contamination than ATP test. AIM To evaluate performance characteristics and optimal cut-off value of A3 and ATP tests in predicting bacterial contamination of duodenoscopes. METHODS Four hundred duodenoscope samples obtained after 100 endoscopic retrograde cholangiopancreatography procedures were randomized into group A (A3 test) or B (ATP test). Samples were collected from the elevator at the four-step cleaning process of duodenoscope. We defined the new cut-off value of the test for reaching 100% negative predictive value (NPV) from our receiver operating characteristic (ROC). FINDINGS Using the cultures from the four-step cleaning process as the reference, the areas under ROC (AUROC) were 0.83 and 0.84 for group A (N = 200) and group B (N = 200), respectively. Using the cultures from post-high-level disinfection (HLD) as the reference, the AUROC were 0.35 and 0.74 for group A (N = 50) and group B (N = 50), respectively. We investigated ATP as a POCT after HLD with a new cut-off value of 40 RLU. However, this threshold did not allow detection of low numbers of bacteria. CONCLUSION A3 and ATP tests provide good performances in predicting bacterial contamination of duodenoscopes for the four-step cleaning process. The ATP <40 RLU is helpful as a POCT after HLD; however, the limitation of this cut-off value is its inability to detect low numbers of bacteria.
Collapse
|
40
|
Muthusamy VR, Bruno MJ, Kozarek RA, Petersen BT, Pleskow DK, Sejpal DV, Slivka A, Peetermans JA, Rousseau MJ, Tirrell GP, Ross AS. Clinical Evaluation of a Single-Use Duodenoscope for Endoscopic Retrograde Cholangiopancreatography. Clin Gastroenterol Hepatol 2020; 18:2108-2117.e3. [PMID: 31706060 DOI: 10.1016/j.cgh.2019.10.052] [Citation(s) in RCA: 59] [Impact Index Per Article: 14.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/07/2019] [Accepted: 10/11/2019] [Indexed: 02/07/2023]
Abstract
BACKGROUND & AIMS Disposable, single-use duodenoscopes might reduce outbreaks of infections associated with endoscope reuse. We tested the feasibility, preliminary safety, and performance of a new single-use duodenoscope in patients undergoing endoscopic retrograde cholangiopancreatography (ERCP). METHODS We conducted a case-series study of the outcomes of ERCP with a single-use duodenoscope from April through May 2019 at 6 academic medical centers. We screened consecutive patients (18 years and older) without alterations in pancreaticobiliary anatomy and enrolled 73 patients into the study. Seven expert endoscopists performed roll-in maneuvers (duodenoscope navigation and visualization of duodenal papilla only) in 13 patients and then ERCPs in the 60 other patients. Outcomes analyzed included completion of ERCP for the intended clinical indication, crossover from a single-use duodenoscope to a reusable duodenoscope, endoscopist performance ratings of the device, and serious adverse events (assessed at 72 hours and 7 days). RESULTS Thirteen (100%) roll-in maneuver cases were completed using the single-use duodenoscope. ERCPs were of American Society for Gastrointestinal Endoscopy procedural complexity grade 1 (least complex; 7 patients [11.7%]), grade 2 (26 patients [43.3%]), grade 3 (26 patients [43.3%]), and grade 4 (most complex; 1 patient [1.7%]). Fifty-eight ERCPs (96.7%) were completed using the single-use duodenoscope only and 2 ERCPs (3.3%) were completed using the single-use duodenoscope followed by crossover to a reusable duodenoscope. Median overall satisfaction was 9 out of 10. Three patients developed post-ERCP pancreatitis, 1 patient had post-sphincterotomy bleeding, and 1 patient had worsening of a preexisting infection and required rehospitalization. CONCLUSIONS In a case-series study, we found that expert endoscopists can complete ERCPs of a wide range of complexity using a single-use duodenoscope for nearly all cases. This alternative might decrease ERCP-related risk of infection. Clinicaltrials.gov no: NCT03701958.
Collapse
|
41
|
Liu TC, Peng CL, Wang HP, Huang HH, Chang WK. SpyGlass application for duodenoscope working channel inspection: Impact on the microbiological surveillance. World J Gastroenterol 2020; 26:3767-3779. [PMID: 32774056 PMCID: PMC7383844 DOI: 10.3748/wjg.v26.i26.3767] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/18/2020] [Revised: 05/28/2020] [Accepted: 06/23/2020] [Indexed: 02/06/2023] Open
Abstract
BACKGROUND Patient-ready duodenoscopes were designed with an assumed contamination rate of less than 0.4%; however, it has been reported that 5.4% of clinically used duodenoscopes remain contaminated with viable high-concern organisms despite following the manufacturer’s instructions. Visual inspection of working channels has been proposed as a quality control measure for endoscope reprocessing. There are few studies related to this issue.
AIM To investigate the types, severity rate, and locations of abnormal visual inspection findings inside patient-ready duodenoscopes and their microbiological significance.
METHODS Visual inspections of channels were performed in 19 patient-ready duodenoscopes using the SpyGlass visualization system in two endoscopy units of tertiary care teaching hospitals (Tri-Service General Hospital and National Taiwan University Hospital) in Taiwan. Inspections were recorded and reviewed to evaluate the presence of channel scratches, buckling, stains, debris, and fluids. These findings were used to analyze the relevance of microbiological surveillance.
RESULTS Seventy-two abnormal visual inspection findings in the 19 duodenoscopes were found, including scratches (n = 10, 52.6%), buckling (n = 15, 78.9%), stains (n = 14, 73.7%), debris (n = 14, 73.7%), and fluids (n = 6, 31.6%). Duodenoscopes > 12 mo old had a significantly higher number of abnormal visual inspection findings than those ≤ 12 mo old (46 findings vs 26 findings, P < 0.001). Multivariable regression analyses demonstrated that the bending section had a significantly higher risk of being scratched, buckled, and stained, and accumulating debris than the insertion tube. Debris and fluids showed a significant positive correlation with microbiological contamination (P < 0.05). There was no significant positive Spearman’s correlation coefficient between negative bacterial cultures and debris, between that and fluids, and the concomitance of debris and fluids. This result demonstrated that the presence of fluid and debris was associated with positive cultures, but not negative cultures. Further multivariate analysis demonstrated that fluids, but not debris, is an independent factor for bacterial culture positivity.
CONCLUSION In patient-ready duodenoscopes, scratches, buckling, stains, debris, and fluids inside the working channel are common, which increase the microbiological contamination susceptibility. The SpyGlass visualization system may be recommended to identify suboptimal reprocessing.
Collapse
|
42
|
Widmer AF, Richner G. Proposal for a EN 149 acceptable reprocessing method for FFP2 respirators in times of severe shortage. Antimicrob Resist Infect Control 2020; 9:88. [PMID: 32552867 PMCID: PMC7298450 DOI: 10.1186/s13756-020-00744-3] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2020] [Accepted: 05/29/2020] [Indexed: 11/10/2022] Open
Abstract
INTRODUCTION Transmission of SARS-CoV-2 to health care workers (HCW) poses a major burden in the current COVID-19 pandemic. Unprotected exposure to a COVID-19 patient is a key risk factor for HCWs. Transmission mainly occurs by droplet transmission, or by aerosol generating procedures. Respirators such as filtering face piece masks (FFP2), also called respirators, are required to prevent transmission during aerosol generating procedures, as part of the personal protective equipment (PPE) for HCWs. However, many HCW were infected due to lack of PPE, or failure to use them. Therefore, the worldwide shortage of respirators triggered the development of reprocessing used FFP2 respirators or N95 respirators as standard in the US. Our proposal with H2O2 plasma sterilization for decontamination allows to reprocess FFP2, while they still meet the filtration efficiency required by EN 149. The protocol is simple, uses available resources in hospitals and can be rapidly implemented to decrease the shortage of respirators during this crisis. The goal of the study was the evaluate if respirators can be reprocessed and still fulfill the requirements for filtration efficiency outlined by EN 149. METHODS Used FFP2 respirators - Model 3 M Aura™ 1862+ - were sterilized using a low temperature process hydrogen peroxide (H2O2), V-PRO® maX Low Temperature, a FDA (Food and Drug Administration) approved method to decontaminate FFP2 respirators. Decontaminated respirators were further checked for residual peroxide by a single-gas detector for H2O2. The total inward leakage of the protective respirators was quantitatively tested with 10 test persons in an atmosphere charged with paraffin aerosol according to the European Standard EN 149. The fit factor was calculated as the inverse of the total inward leakage. RESULTS Ten new and ten decontaminated FFP2 respirators were tested for filtration efficiency. None of the respirators exceeded the maximum acceptable concentration of peroxide. More than 4000 respirators have been reprocessed so far, at cost of approximately 0.3 Euro/piece. CONCLUSIONS FFP2 respirators can be safely reprocessed once after decontamination with plasma peroxide sterilization, whereafter they still fulfill EN 149 requirements. This allows to almost double the current number of available FFP2 respirators.
Collapse
|
43
|
UV light-based decontamination: an effective and fast way for disinfection of endoscopes in otorhinolaryngology? Eur Arch Otorhinolaryngol 2020; 277:2363-2369. [PMID: 32358650 PMCID: PMC7335372 DOI: 10.1007/s00405-020-05978-w] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2020] [Accepted: 04/10/2020] [Indexed: 12/28/2022]
Abstract
Background Reprocessing of endoscopes becomes increasingly complex, due to rising demands of hygiene. Established methods are often expensive/time-consuming. Recent studies suggest beneficial aspects of disinfection by UV light. In this study we analyzed the efficiency of UV light disinfection of rigid otorhinolaryngological endoscopes. Materials and methods After mechanical pre-cleaning, the endoscopes were decontaminated for 25 s in the D25 using Impelux™ UV C light technology (UV Smart B.V., Delft, The Netherlands). First, the surface contact samples were taken from 50 used endoscopes to evaluate the bacterial load. Additionally, surface contact samples were taken from further 50 used endoscopes after reprocessing with the D25. Another 50 endoscopes were tested on protein residuals. Furthermore, the absolute effectiveness of the D25 was tested on 50 test bodies (RAMS) with a standardized contamination of 107 colony-forming units (CFU) of Enterococcus faecium. Results The used endoscopes showed a high bacterial contamination with an average value of 66.908 (± 239.215) CFU. After reprocessing, only a minimal contamination on 10% (n = 5) of the endoscopes with a mean value of 0.12 CFU (± 0.39) was found, resulting in a log-5 reduction in a clinical environment. The documented bacteria were components of the normal skin flora. All tested endoscopes were practically protein-free (< 1 μg). Furthermore, the average absolute germ reduction of the D25 was about 106 CFU on the tested RAMS. Conclusion The D25 UV light system seems to be an effective device for the reprocessing of rigid ORL endoscopes, and therefore, might be suitable for the usage in clinical practice on site.
Collapse
|
44
|
Tofanelli M, Capriotti V, Saraniti C, Marcuzzo AV, Boscolo-Rizzo P, Tirelli G. Disposable chlorine dioxide wipes for high-level disinfection in the ENT department: A systematic review. Am J Otolaryngol 2020; 41:102415. [PMID: 32059828 DOI: 10.1016/j.amjoto.2020.102415] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2020] [Accepted: 02/02/2020] [Indexed: 11/28/2022]
Abstract
BACKGROUND Nasopharyngoscope reprocessing methods should be effective, rapid and reproducible with moderate cost. Tristel Trio Wipes system (TTWS) is a manual reprocessing method based on chlorine dioxide that has lately emerged in ENT department. This review aims to collect evidence on this system. METHODS The PubMed, Web of Science and Cochrane Library databases were searched for all the studies on TTWS or one of its components. Data were grouped according to the study type. RESULTS Ten articles were included in the review. TTWS ensured high-level disinfection in laboratory and clinical setting. Although the limitations of the manual systems, TTWS proved to be faster than automated endoscope reprocessing (AER) and safe for patients and health-care workers. TTWS represented cheaper system than AER or sheaths in low- and medium-volume centers. CONCLUSION TTWS could be a valid, safe and fast HLD method for nasopharyngoscopes, with reasonable costs for medium-low reprocessing volumes.
Collapse
|
45
|
Dinis MDL, Fiúza A, Futuro A, Leite A, Martins D, Figueiredo J, Góis J, Vila MC. Characterization of a mine legacy site: an approach for environmental management and metals recovery. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2020; 27:10103-10114. [PMID: 31975010 PMCID: PMC7089905 DOI: 10.1007/s11356-019-06987-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/11/2019] [Accepted: 11/06/2019] [Indexed: 06/10/2023]
Abstract
The characterization of historical mine tailings provides important information for land-management decisions, in particular when considering potential reprocessing activities or the development of an environmental protection program. In addition, outcomes from such characterization may define the scope for a more detailed investigation. The present work describes the characterization of the waste material from the Cabeço do Pião tailings impoundment performed within the project ReMinE: Improve Resource Efficiency and Minimize Environmental Footprint. The purpose of the work was to investigate alternative mine waste management options such as the extraction of valuable resources from an environmental liability. The study involved the collection of 41 samples at different locations at two different depths, physical and chemical characterization of the wastes, natural leaching tests, and potential for acid generation. The results showed that, apart from the potential instability of the dyke (with an average slope of 35°), the drained solutions flowing by percolation contain very small particles with high arsenic contents that are being incorporated into the river sediments. In addition, these very fine-grained materials are available for the transport by the wind creating secondary sources of environmental contamination. This data is fundamental for economic and environmental assessment of the two main alternatives, reprocessing or removal.
Collapse
|
46
|
Balan GG, Sfarti CV, Chiriac SA, Stanciu C, Trifan A. Duodenoscope-associated infections: a review. Eur J Clin Microbiol Infect Dis 2019; 38:2205-2213. [PMID: 31482418 DOI: 10.1007/s10096-019-03671-3] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2019] [Accepted: 08/05/2019] [Indexed: 02/08/2023]
Abstract
Flexible digestive endoscopes are used for the management of various conditions with hundreds of thousands of therapeutic procedures performed worldwide each year. Duodenoscopes are indispensable tools for the delivery of minimally invasive vital care of numerous pancreaticobiliary disorders. Despite the fact that nosocomial infections after endoscopic retrograde cholangiopancreatography (ERCP) have always been among the most frequently cited postprocedural complications, recent emergence of duodenoscope-transmitted multiple drug-resistant bacterial infections has led to intense research and debate yet with no clearly delineated solution. Duodenoscope-transmitted nosocomial infections have become one of the most visible topics in the recent literature. Hundreds of high-impact articles have therefore been published in the last decade. This review article discusses how such infections were seen in the past and what is the current situation in both research and practice and thus tries to solve some of the unanswered questions for the future. With the persistence of nosocomial infections despite strict adherence to both manufacturer-issued reprocessing protocols and international guidelines and regulations, an urgent and proper microbiologically driven common action is needed for controlling such nosocomial worldwide threat.
Collapse
|
47
|
Enhanced manual cleaning efficacy of duodenoscope in endoscopy units: Results of a multicenter comprehensive quality control program. Am J Infect Control 2019; 47:1233-1239. [PMID: 31126624 DOI: 10.1016/j.ajic.2019.03.029] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2018] [Revised: 03/21/2019] [Accepted: 03/21/2019] [Indexed: 12/11/2022]
Abstract
BACKGROUND Multiple outbreaks from contaminated duodenoscopes have been reported since 2008. This study assessed results of a multicenter comprehensive quality control (QC) program to enhance manual cleaning efficacy of duodenoscopes in endoscopy units. METHODS Digestive Endoscopy Society of Taiwan implemented a QC program with adenosine triphosphate (ATP) testing of patient-used duodenoscopes in 2 rounds of on-site audit in endoscopy units. ATP samples were obtained from 5 different locations of the duodenoscope after manual cleaning. Duodenoscope exceeding ATP benchmark of 200 relative light units indicated inadequate manual cleaning. RESULTS During the first round on-site audit, 12 hospitals and 27 patient-used duodenoscopes were analyzed. Distal end outer surface (29.6%), elevator mechanism (51.9%), distal attachment cap (59.3%), elevator wire channel (37.0%), and suction biopsy channel (37.0%) were inadequately cleaned. Overall, 19 (70.4%) duodenoscopes had inadequate manual cleaning, ranging widely from 0%-100% among endoscopy units. During the follow-up on-site audit, 32 patient-used duodenoscopes were analyzed, and 6 (18.8%) had inadequate manual cleaning. CONCLUSIONS ATP tests may provide real-time feedback on the cleaning efficacy of patient-used duodenoscopes. Implementing a comprehensive QC program could enhance the efficacy of manual cleaning in endoscopy units.
Collapse
|
48
|
Kampf G, Jung M, Suchomel M, Saliou P, Griffiths H, Vos MC. Prion disease and recommended procedures for flexible endoscope reprocessing - a review of policies worldwide and proposal for a simplified approach. J Hosp Infect 2019; 104:92-110. [PMID: 31408691 DOI: 10.1016/j.jhin.2019.08.005] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2019] [Accepted: 08/05/2019] [Indexed: 10/26/2022]
Abstract
Several guidelines recommend specific treatments for endoscopes, procedures of quarantine for endoscopes, or additional treatments for the endoscope washer disinfector (EWD) in suspected or confirmed cases of Creutzfeldt-Jakob disease (CJD) or variant CJD (vCJD) but vary in many details. This study therefore reviewed guidelines on reprocessing flexible endoscopes after use in patients with suspected or confirmed prion disease. In addition, a literature search was performed in Medline on prion, CJD, vCJD, chemical inactivation, transmission healthcare, epidemiology healthcare, concentration tissue human and endoscope. Thus far, no case of CJD or vCJD transmitted by flexible endoscope has been reported. In animals it has been shown that oral uptake of 0.1-5 g of bovine spongiform encephalopathy (BSE)-infected brain homogenate is necessary for transmission. The maximum prion concentration in other tissues (e.g., terminal ileum) is at least 100-fold lower. Automated cleaning of endoscopes alone results in very low total residual protein ≤5.6 mg per duodenoscopes. Recommendations vary between countries, sometimes with additional cleaning, use of alkaline cleaners, no use of cleaners with fixative properties, use of disinfectants without fixative properties or single-use disinfectants. Sodium hydroxide (1 M) and sodium hypochlorite (10,000 and 25,000 mg/L) are very effective in preventing transmission via contaminated wires implanted into animal brains, but their relevance for endoscopes is questionable. Based on circumstantial evidence, it is proposed to consider validated reprocessing as appropriate in the case of delayed suspected prion disease when immediate bedside cleaning, routine use of alkaline cleaners, no fixative agents anywhere prior to disinfection and single use brushes and cleaning solutions can be assured.
Collapse
|
49
|
Ofstead CL, Hopkins KM, Eiland JE, Wetzler HP. Widespread clinical use of simethicone, insoluble lubricants, and tissue glue during endoscopy: A call to action for infection preventionists. Am J Infect Control 2019; 47:666-670. [PMID: 30922624 DOI: 10.1016/j.ajic.2019.02.012] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2019] [Revised: 02/10/2019] [Accepted: 02/11/2019] [Indexed: 12/18/2022]
Abstract
BACKGROUND Current methods for reprocessing flexible endoscopes do not consistently eliminate organic soil. The off-label use of simethicone as a defoaming agent may contribute to reprocessing failures, and endoscope manufacturers have cautioned against its use. METHODS We sought evidence of simethicone use by interviewing hospital personnel, conducting audits, inspecting endoscopes, and conducting tests. RESULTS Researchers examined 69 fully reprocessed endoscopes in 4 hospitals. Microbial cultures were positive for ≥50% of endoscopes. Researchers observed cloudy, shimmery fluid resembling simethicone inside channels and under a duodenoscope elevator mechanism. Crystallized white fragments were observed protruding from a gastroscope water jet outlet. Oily, sticky residue was found on endoscopes, and a 3-dimensional mass was found inside an endoscopic ultrasound endoscope. Hospital personnel reported the use of simethicone, cooking oil and silicone sprays, and tissue glue during endoscopy. DISCUSSION The off-label use of defoaming agents, lubricants, and tissue glue is common and many endoscopists consider these products essential. Our findings suggest these substances are not removed during reprocessing and may impact reprocessing effectiveness. CONCLUSIONS Infection preventionists should determine whether these products are used in their institutions and evaluate methods for removing them. New policies may be needed to support procedural success and effective endoscope reprocessing.
Collapse
|
50
|
Wang D, Wu J. Reprocessing and reuse of single-use medical devices in China: a pilot survey. BMC Public Health 2019; 19:461. [PMID: 31039773 PMCID: PMC6492401 DOI: 10.1186/s12889-019-6835-9] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2019] [Accepted: 04/15/2019] [Indexed: 11/20/2022] Open
Abstract
Background In China, reprocessing and reuse of single-use medical devices (SUDs) are banned. However, the actual situation has not been reported so far. The study aims to clarify the perceptions and concerns of various sectors of the community on the reuse of SUDs, and whether such practice exists. In addition, we are also wondering how acceptable the respondents are on this matter. Methods A cross-sectional study based on a national survey which was conducted on the professional online questionnaire survey platform (www.wjx.cn) from July 26 to August 4, 2015. We analyzed the data according to the work fields, sex, age, education level, professional background and participants’ answers to 49 other questions. Results Five hundred forty-four nationwide respondents belong to nine different work fields. In general, participants had positive attitudes towards the reprocessing and reuse of SUDs. However, many respondents doubted the hygienic and functional safety of the reprocessed SUDs. They also tended to think that the reuse of SUDs should have lower prices and more technical training as well as patient advocacy. Further analysis demonstrated the work fields, education level and professional background of respondents were statistically associated with their responses to certain questions. Conclusions The research indicated that although the reuse of SUDs is prohibited legally in China, there were extensive reprocessing and reuse in hospitals. Most responses tended to accept reprocessed SUDs if safety and low prices were guaranteed. These existing contradictions and the lack of relevant research led to policy makers in China will confront numerous challenges in building and improving this use system of medical devices to meet escalating demands of social sectors. Electronic supplementary material The online version of this article (10.1186/s12889-019-6835-9) contains supplementary material, which is available to authorized users.