26
|
Young A, Patel K, Allen K, Ghadersohi S, Rowland M, Hazkani I. Flexible and Rigid Bronchoscopy for Critically Ill Children on Extracorporeal Membrane Oxygenation. Laryngoscope 2024. [PMID: 38651446 DOI: 10.1002/lary.31460] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2023] [Revised: 03/13/2024] [Accepted: 04/09/2024] [Indexed: 04/25/2024]
Abstract
BACKGROUND We aim to describe our experience with bronchoscopy to diagnose and relieve tracheobronchial obstruction in anticipation of decannulation in children on extracorporeal membrane oxygenation (ECMO) support. METHODS A retrospective cohort study of children on ECMO between 1/2018 and 12/2022. RESULTS A total of 107 children required ECMO support during the study period for cardiac (n = 48, 45%), pulmonary (n = 38, 36%), or cardiopulmonary dysfunction (n = 21, 20%). Thirty-seven (35%) patients underwent 99 bronchoscopies while on ECMO. Most (76%, n = 75) experienced no improvement or worsening of chest radiography 24 hours following bronchoscopy. Clinical improvement in tidal volumes 48 hours after the first bronchoscopy was noted in 13/25 patients with available data (p = 0.05). Adverse events were seen in 18 (49%) patients who underwent bronchoscopy, including pneumothorax (n = 8, 22%), pneumonia (n = 7, 19%), pulmonary hemorrhage (n = 6, 16%), and sepsis (n = 5, 14%). ECMO courses were longer (25.4 ± 37.2 vs 6.1 ± 8.8 days, p < 0.0001) and more likely to be complicated by pneumonia (p = 0.0004) and sepsis (p = 0.047) in patients who underwent bronchoscopy compared with those who did not. Adverse events following bronchoscopy were associated with the number of bronchoscopies (p = 0.0003) and the presence of obstructive materials but not with the type of bronchoscopy or indication for ECMO. Mortality rates were similar between patients who underwent bronchoscopy and those who did not. CONCLUSION Children requiring bronchoscopy represent a subset of the sickest children on ECMO. Bronchoscopy may provide benefit in children with persistent cardiopulmonary failure who could not otherwise be decannulated. Adverse events are associated with the number of bronchoscopies and the presence of obstructive material. LEVEL OF EVIDENCE 4 Laryngoscope, 2024.
Collapse
|
27
|
Li Y, Cai W, Tao R, Shuai W, Rao J, Chang C, Lu X, Ning H. Flexible and Energy-Efficient Synaptic Transistor with Quasi-Linear Weight Update Protocol by Inkjet Printing of Orientated Polar-Electret/High- k Oxide Composite Dielectric. ACS APPLIED MATERIALS & INTERFACES 2024; 16:19271-19282. [PMID: 38591357 DOI: 10.1021/acsami.4c02880] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/10/2024]
Abstract
Inkjet printing artificial synapse is cost-effective but challenging in emulating synaptic dynamics with a sufficient number of effective weight states under ultralow voltage spiking operation. A synaptic transistor gated by inkjet-printed composite dielectric of polar-electret polyvinylpyrrolidone (PVP) and high-k zirconia oxide (ZrOx) is proposed and thus synthesized to solve this issue. Quasi-linear weight update with a large variation margin is obtained through the coupling effect and the facilitation of dipole orientation, which can be attributed to the orderly arranged molecule chains induced by the carefully designed microfluidic flows. Crucial features of biological synapses including long-term plasticity, spike-timing-dependence-plasticity (STDP), "Learning-Experience" behavior, and ultralow energy consumption (<10 fJ/pulse) are successfully implemented on the device. Simulation results exhibit an excellent image recognition accuracy (97.1%) after 15 training epochs, which is the highest for printed synaptic transistors. Moreover, the device sustained excellent endurance against bending tests with radius down to 8 mm. This work presents a very viable solution for constructing the futuristic flexible and low-cost neural systems.
Collapse
|
28
|
Zhuang Y, Wang X, Lai P, Li J, Chen L, Lin Y, Wang F. Wireless Flexible System for Highly Sensitive Ammonia Detection Based on Polyaniline/Carbon Nanotubes. BIOSENSORS 2024; 14:191. [PMID: 38667184 PMCID: PMC11048023 DOI: 10.3390/bios14040191] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/09/2024] [Revised: 04/11/2024] [Accepted: 04/11/2024] [Indexed: 04/28/2024]
Abstract
Ammonia (NH3) is a harmful atmospheric pollutant and an important indicator of environment, health, and food safety conditions. Wearable devices with flexible gas sensors offer convenient real-time NH3 monitoring capabilities. A flexible ammonia gas sensing system to support the internet of things (IoT) is proposed. The flexible gas sensor in this system utilizes polyaniline (PANI) with multiwall carbon nanotubes (MWCNTs) decoration as a sensitive material, coated on a silver interdigital electrode on a polyethylene terephthalate (PET) substrate. Gas sensors are combined with other electronic components to form a flexible electronic system. The IoT functionality of the system comes from a microcontroller with Wi-Fi capability. The flexible gas sensor demonstrates commendable sensitivity, selectivity, humidity resistance, and long lifespan. The experimental data procured from the sensor reveal a remarkably low detection threshold of 0.3 ppm, aligning well with the required specifications for monitoring ammonia concentrations in exhaled breath gas, which typically range from 0.425 to 1.8 ppm. Furthermore, the sensor demonstrates a negligible reaction to the presence of interfering gases, such as ethanol, acetone, and methanol, thereby ensuring high selectivity for ammonia detection. In addition to these attributes, the sensor maintains consistent stability across a range of environmental conditions, including varying humidity levels, repeated bending cycles, and diverse angles of orientation. A portable, stable, and effective flexible IoT system solution for real-time ammonia sensing is demonstrated by collecting data at the edge end, processing the data in the cloud, and displaying the data at the user end.
Collapse
|
29
|
Bhardwaj S, Singh S, Dev K, Chhajed M, Maji PK. Harnessing the Flexibility of Lightweight Cellulose Nanofiber Composite Aerogels for Superior Thermal Insulation and Fire Protection. ACS APPLIED MATERIALS & INTERFACES 2024; 16:18075-18089. [PMID: 38560888 DOI: 10.1021/acsami.4c01803] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/04/2024]
Abstract
Thermally insulating materials from renewable and readily available resources are in high demand for ecologically beneficial applications. Cellulose aerogels made from lignocellulosic waste have various advantages. However, they are fragile and breakable when bent or compressed. In addition, cellulose aerogels are flammable and weather-sensitive. Hence, to overcome these problems, this work included the preparation of polyurethane (PU)-based cellulose nanofiber (CNF) aerogels that had flexibility, flame retardancy, and thermal insulation. Methyl trimethoxysilane (MTMS) and water-soluble ammonium polyphosphate (APP) were added to improve the cross-linking, hydrophobicity, and flame-retardant properties of aerogels. The flexibility of chemically cross-linked CNF aerogels is enhanced through the incorporation of polyurethane via the wet coagulating process. The aerogels obtained during this study have exhibited low weight (density: 35.3-91.96 kg/m3) together with enhanced hydrophobic properties, flame retardancy, and decreased thermal conductivity (26.7-36.7 mW/m K at 25 °C). Additionally, the flame-retardant properties were comprehensively examined and the underlying mechanism was deduced. The aerogels prepared in this study are considered unique in the nanocellulose aerogel category due to their integrated structural and performance benefits. The invention is considered to substantially contribute to the large-scale manufacture and use of insulation in construction, automobiles, and aerospace.
Collapse
|
30
|
Yu B, Luo Z, Zhou Y, Zhang Q, He J, Fan J. Highly Thermally Conductive Flexible Biomimetic APTES-BNNS/BC Nanocomposite Paper by Sol-Gel-Film Technology. ACS APPLIED MATERIALS & INTERFACES 2024. [PMID: 38592441 DOI: 10.1021/acsami.4c00593] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/10/2024]
Abstract
Owing to the evolution of 5G technology, new energy vehicles, flexible electronics, miniaturization and integration of microelectronic devices, high-frequency and high-power devices, and thermal management of materials must consider additional limitations such as electrical insulation, excellent transverse heat transfer, flexibility, and weight. Boron nitride nanosheets (BNNSs) are ideal insulating materials with high thermal conductivity. However, the problem of the 3D thermal conductivity pathway and toughness strength of nanocomposite paper loaded with inorganic thermal conductivity fillers remains a huge challenge. In this study, we propose a new method for preparing ultrathin, large, and uniformly thick BNNS for quantitative production. Bulk hexagonal boron nitride (hBN) layers were exfoliated using a simple and low-cost hydrothermal reaction, and large-scale fewer-layered BNNSs were efficiently prepared by ball milling with a high yield (up to 80%). Based on the aforementioned step, a flexible insulating composite film with high thermal conductivity and a natural "brick-mud" shell structure was constructed via the sol-gel-film conversion method. After prestretching and hot-pressing treatment, the hydrogels became denser, and the modified BNNS formed a three-dimensional (3D) network structure with an ordered orientation and interconnections in the bacterial cellulose (BC) matrix. After 100 folding cycles, the tensile strength of the nanofiber composite film reached 53 MPa, and the strength retention rate exceeded 42%. By optimizing the modified BNNS content, the thermal conductivity reached 24 W/(m·K). This simple approach has wide application potential in the next-generation electronic devices, providing options for designing thermal interface materials with excellent electrical insulation, high thermal stability, and flexibility.
Collapse
|
31
|
Bhol P, Jagdale PB, Jadhav AH, Saxena M, Samal AK. All-Solid-State Supercapacitors Based on Cobalt Magnesium Telluride Microtubes Decorated with Tellurium Nanotubes. CHEMSUSCHEM 2024; 17:e202301009. [PMID: 38084066 DOI: 10.1002/cssc.202301009] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/13/2023] [Revised: 11/15/2023] [Indexed: 01/28/2024]
Abstract
Magnesium (Mg) has received very little exploration on its importance in the realm of battery-type energy storage technologies. They are abundantly present in seawater, and if successfully extracted and utilized in energy storage systems, it could lead to the long-term advancement of human civilization. Here, we fabricated an all-solid-state supercapacitor (ASSSC) using tellurium nanotubes decorated cobalt magnesium telluride microtubes (Te NTs@CoMgTe MTs) clad on nickel foam (NF). Owing to the unique mixed phase hierarchical structure, Te NTs@CoMgTe MTs showcases some advancement in energy storage performance. When tested in a three-electrode system, multiphasic hybrid of elemental Te and metal tellurides, Te NTs@CoMgTe MTs outperforms the monometallic telluride owing to the strong synergistic interaction effect triggered from conductive three components and delivers a long-life span performance up to 15,000 cycles. The fabricated Te NT@CoMgTe MT//AC solid-state device exhibits a maximum areal capacity of 59.2 μAh cm-2 (56.3 mAh g-1) at a current density of 6 mA cm-2 with a maximum energy density of 42.2 Wh kg-1 (46.5 μWh cm-2) at a power density of 6857.1 W kg-1 (7574.6 μW cm-2). The performance of the device is rigid even at different bending angles (0 to 180°) which validates the extensibility of the process for future applications.
Collapse
|
32
|
Liu X, Cui Q, Li H, Wang S, Zhang Q, Huang W, Liu C, Cai W, Li T, Yang Z, Ma C, Ren L, Liu SF, Zhao K. Biocompatible Metal-Free Perovskite Membranes for Wearable X-ray Detectors. ACS APPLIED MATERIALS & INTERFACES 2024; 16:16300-16308. [PMID: 38513050 DOI: 10.1021/acsami.4c01069] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/23/2024]
Abstract
Halide perovskites are emerging as promising materials for X-ray detection owing to their compatibility with flexible fabrication, cost-effective solution processing, and exceptional carrier transport behaviors. However, the challenge of removing lead from high-performing perovskites, crucial for wearable electronics, while retaining their superior performance, persists. Here, we present for the first time a highly sensitive and robust flexible X-ray detector utilizing a biocompatible, metal-free perovskite, MDABCO-NH4I3 (MDABCO = methyl-N'-diazabicyclo[2.2.2]octonium). This wearable X-ray detector, based on a MDABCO-NH4I3 thick membrane, exhibits remarkable properties including a large resistivity of 1.13 × 1011 Ω cm, a high mobility-lifetime product (μ-τ) of 1.64 × 10-4 cm2 V-1, and spin Seebeck effect coefficient of 1.9 nV K-1. We achieve a high sensitivity of 6521.6 ± 700 μC Gyair-1 cm-2 and a low detection limit of 77 nGyair s-1, ranking among the highest for biocompatible X-ray detectors. Additionally, the device exhibits effective X-ray imaging at a low dose rate of 1.87 μGyair s-1, which is approximately one-third of the dose rate used in regular medical diagnostics. Crucially, both the MDABCO-NH4I3 thick membrane and the device showcase excellent mechanical robustness. These attributes render the flexible MDABCO-NH4I3 thick membranes highly competitive for next-generation, high-performance, wearable X-ray detection applications.
Collapse
|
33
|
Zhou Z, Zhang Y, Bai J, Zhang W, Wang H, Pu W. Bioinspired Flexible Capacitive Sensor for Robot Positioning in Unstructured Environments. ACS APPLIED MATERIALS & INTERFACES 2024; 16:16589-16600. [PMID: 38506508 DOI: 10.1021/acsami.4c00699] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/21/2024]
Abstract
The evolution of bionic machines into intelligent robots to adapt to real scenarios is inseparable from positioning sensors. However, traditional positioning methods such as camera arrays, ultrasound, or GPS are limited in narrow concealed spaces, harsh temperatures, or dynamic light fields, which hinder the practical application of special robots. Here, we report a flexible sensor inspired by Gnathonemus petersii that enables robots to achieve contactless and high-precision spatial localization independent of the unstructured features of the environment. Sensors are obtained from low-cost materials (carbon nanotubes and polyimides) and simple structures (fibers) and preparation processes (spin-coating). Experiments and simulations confirmed the high resolution (<1 mm) of the sensor over a large distance detection range (>150 mm) and high bandwidth (0-520 MPa) of contact force. Moreover, the sensing capability is still feasible when the sensor is bent to various curvatures and not affected under harsh conditions such as ultralow temperatures (below -78 °C), ultrahigh temperatures (over 250 °C), darkness, or brightness. We demonstrate the practical potential of the proposed sensors for a biomimetic hyper-redundant continuum robot to locate and avoid collisions in unstructured environments.
Collapse
|
34
|
Zheng X, Zhou D, Liu Z, Hong X, Li C, Ge S, Cao W. Skin-Inspired Textile Electronics Enable Ultrasensitive Pressure Sensing. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2024:e2310032. [PMID: 38566533 DOI: 10.1002/smll.202310032] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/03/2023] [Revised: 03/16/2024] [Indexed: 04/04/2024]
Abstract
Wearable pressure sensors have attracted great interest due to their potential applications in healthcare monitoring and human-machine interaction. However, it is still a critical challenge to simultaneously achieve high sensitivity, low detection limit, fast response, and outstanding breathability for wearable electronics due to the difficulty in constructing microstructure on a porous substrate. Inspired by the spinosum microstructure of human skin for highly-sensitive tactile perception, a biomimetic flexible pressure sensor is designed and fabricated by assembling MXene-based sensing electrode and MXene-based interdigitated electrode. The product biomimetic sensor exhibits good flexibility and suitable air permeability (165.6 mm s-1), comparable to the typical air permeable garments. Benefiting from the two-stage amplification effect of the bionic intermittent structure, the product bionic sensor exhibits an ultrahigh sensitivity (1368.9 kPa-1), ultrafast response (20 ms), low detection limit (1 Pa), and high-linearity response (R2 = 0.997) across the entire sensing range. Moreover, the pressure sensor can detect a wide range of human motion in real-time through intimate skin contact, providing essential data for biomedical monitoring and personal medical diagnosis. This principle lays a foundation for the development of human skin-like high-sensitivity, fast-response tactile sensors.
Collapse
|
35
|
Zou Y, Li P, Su C, Yan J, Zhao H, Zhang Z, You Z. Flexible High-Temperature MoS 2 Field-Effect Transistors and Logic Gates. ACS NANO 2024; 18:9627-9635. [PMID: 38489156 DOI: 10.1021/acsnano.3c13220] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/17/2024]
Abstract
High-temperature-resistant integrated circuits with excellent flexibility, a high integration level (nanoscale transistors), and low power consumption are highly desired in many fields, including aerospace. Compared with conventional SiC high-temperature transistors, transistors based on two-dimensional (2D) MoS2 have advantages of superb flexibility, atomic scale, and ultralow power consumption. However, MoS2 cannot survive at high temperature and drastically degrades above 200 °C. Here, we report MoS2 field-effect transistors (FETs) with top/bottom hexagonal boron nitride (h-BN) encapsulation and graphene electrodes. With the protection of the h-BN/h-BN structure, the devices can survive at much higher temperature (≥500 °C in air) than those of the MoS2 devices ever reported, which provides us an opportunity to explore the electrical properties and working mechanism of MoS2 devices at high temperature. Unlike the relatively low-temperature situation, the on/off ratio and subthreshold swing of MoS2 FETs show drastic variation at elevated temperature due to the injection of thermal emission carriers. Compared with metal electrode, devices with a graphene electrode demonstrate superior performance at high temperature (∼1-order-larger current on/off ratio, 3-7 times smaller subthreshold swing, and 5-9 times smaller threshold voltage shift). We further realize that the flexible CMOS NOT gate based on the above technique, and demonstrate logic computing at 550 °C. This work may stimulate the fundamental research of properties of 2D materials at high temperature, and also creates conditions for next-generation flexible harsh-environment-resistant integrated circuits.
Collapse
|
36
|
Pan F, Shi Y, Yang Y, Guo H, Li L, Jiang H, Wang X, Zeng Z, Lu W. Porifera-Inspired Lightweight, Thin, Wrinkle-Resistance, and Multifunctional MXene Foam. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2024; 36:e2311135. [PMID: 38146773 DOI: 10.1002/adma.202311135] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/24/2023] [Revised: 12/14/2023] [Indexed: 12/27/2023]
Abstract
Transition metal carbides/nitrides (MXenes) demonstrate a massive potential in constructing lightweight, multifunctional wearable electromagnetic interference (EMI) shields for application in various fields. Nevertheless, it remains challenging to develop a facile, scalable approach to prepare the MXene-based macrostructures characterized by low density, low thickness, high mechanical flexibility, and high EMI SE at the same time. Herein, the ultrathin MXene/reduced graphene oxide (rGO)/Ag foams with a porifera-inspired hierarchically porous microstructure are prepared by combining Zn2+ diffusion induction and hard template methods. The hierarchical porosity, which includes a mesoporous skeleton and a microporous MXene network within the skeleton, not only exerts a regulatory effect on stress distribution during compression, making the foams rubber-like resistant to wrinkling but also provides more channels for multiple reflections of electromagnetic waves. Due to the interaction between Ag nanosheets, MXene/rGO, and porous structure, it is possible to produce an outstanding EMI shielding performance with the specific surface shielding effectiveness reaching 109152.4 dB cm2 g-1. Furthermore, the foams exhibit multifunctionalities, such as transverse Joule heating, longitudinal heat insulation, self-cleaning, fire resistance, and motion detection. These discoveries open up a novel pathway for the development of lightweight MXene-based materials with considerable application potential in wearable electromagnetic anti-interference devices.
Collapse
|
37
|
Berglin M, Cavanagh JP, Caous JS, Thakkar BS, Vasquez JM, Stensen W, Lyvén B, Svendsen JS, Svenson J. Flexible and Biocompatible Antifouling Polyurethane Surfaces Incorporating Tethered Antimicrobial Peptides through Click Reactions. Macromol Biosci 2024; 24:e2300425. [PMID: 38009664 DOI: 10.1002/mabi.202300425] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2023] [Revised: 10/30/2023] [Indexed: 11/29/2023]
Abstract
Efficient, simple antibacterial materials to combat implant-associated infections are much in demand. Herein, the development of polyurethanes, both cross-linked thermoset and flexible and versatile thermoplastic, suitable for "click on demand" attachment of antibacterial compounds enabled via incorporation of an alkyne-containing diol monomer in the polymer backbone, is described. By employing different polyolic polytetrahydrofurans, isocyanates, and chain extenders, a robust and flexible material comparable to commercial thermoplastic polyurethane is prepared. A series of short synthetic antimicrobial peptides are designed, synthesized, and covalently attached in a single coupling step to generate a homogenous coating. The lead material is shown to be biocompatible and does not display any toxicity against either mouse fibroblasts or reconstructed human epidermis according to ISO and OECD guidelines. The repelling performance of the peptide-coated materials is illustrated against colonization and biofilm formation by Staphylococcus aureus and Staphylococcus epidermidis on coated plastic films and finally, on coated commercial central venous catheters employing LIVE/DEAD staining, confocal laser scanning microscopy, and bacterial counts. This study presents the successful development of a versatile and scalable polyurethane with the potential for use in the medical field to reduce the impact of bacterial biofilms.
Collapse
|
38
|
Du C, Zhang H, Liu X, Zhou S, Ma Y, Li S, Zhang Y. Flexible and Simply Degradable MXene-Methylcellulose Piezoresistive Sensor for Human Motion Detection. ACS APPLIED MATERIALS & INTERFACES 2024; 16:12996-13005. [PMID: 38422506 DOI: 10.1021/acsami.3c16125] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/02/2024]
Abstract
Flexible pressure sensors are intensively demanded in various fields such as electronic skin, medical and health detection, wearable electronics, etc. MXene is considered an excellent sensing material due to its benign metal conductivity and adjustable interlayer distance. Exhibiting both high sensitivity and long-term stability is currently an urgent pursuit in MXene-based flexible pressure sensors. In this work, high-strength methylcellulose was introduced into the MXene film to increase the interlayer distance of 2D nanosheets and fundamentally overcome the self-stacking problem. Thus, concurrent improvement of the sensing capability and mechanical strength was obtained. By appropriately modulating the ratio of methylcellulose and MXene, the obtained pressure sensor presents a high sensitivity of 19.41 kPa-1 (0.88-24.09 kPa), good stability (10000 cycles), and complete biodegradation in H2O2 solution within 2 days. Besides, the sensor is capable of detecting a wide range of human activities (pulse, gesture, joint movement, etc.) and can precisely recognize spatial pressure distribution, which serves as a good candidate for next-generation wearable electronic devices.
Collapse
|
39
|
Abd El-Hameed AS, Elsheakh DM, Elashry GM, Abdallah EA. A Comparative Study of Narrow/Ultra-Wideband Microwave Sensors for the Continuous Monitoring of Vital Signs and Lung Water Level. SENSORS (BASEL, SWITZERLAND) 2024; 24:1658. [PMID: 38475194 DOI: 10.3390/s24051658] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/01/2023] [Revised: 11/28/2023] [Accepted: 01/31/2024] [Indexed: 03/14/2024]
Abstract
This article presents an in-depth investigation of wearable microwave antenna sensors (MASs) used for vital sign detection (VSD) and lung water level (LWL) monitoring. The study looked at two different types of MASs, narrowband (NB) and ultra-wideband (UWB), to decide which one was better. Unlike recent wearable respiratory sensors, these antennas are simple in design, low-profile, and affordable. The narrowband sensor employs an offset-feed microstrip transmission line, which has a bandwidth of 240 MHz at -10 dB reflection coefficient for the textile substrate. The UWB microwave sensor uses a CPW-fed line to excite an unbalanced U-shaped radiator, offering an extended simulated operating bandwidth from 1.5 to 10 GHz with impedance matching ≤-10 dB. Both types of microwave sensors are designed on a flexible RO 3003 substrate and textile conductive fabric attached to a cotton substrate. The specific absorption rate (SAR) of the sensors is measured at different resonant frequencies on 1 g and 10 g of tissue, according to the IEEE C95.3 standard, and both sensors meet the standard limit of 1.6 W/kg and 2 W/kg, respectively. A simple peak-detection algorithm is used to demonstrate high accuracy in the detection of respiration, heartbeat, and lung water content. Based on the experimental results on a child and an adult volunteer, it can be concluded that UWB MASs offer superior performance when compared to NB sensors.
Collapse
|
40
|
Chang Q, Ji J, Chen K, Wu W, Ma Y. Transparent and Ultra-Thin Flexible Checkerboard Metasurface for Radar-Infrared Bi-Stealth. SENSORS (BASEL, SWITZERLAND) 2024; 24:1531. [PMID: 38475067 DOI: 10.3390/s24051531] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/23/2024] [Revised: 02/22/2024] [Accepted: 02/26/2024] [Indexed: 03/14/2024]
Abstract
This paper proposed a single-layer checkerboard metasurface with simultaneous wideband radar cross-section (RCS) reduction characteristics and low infrared (IR) emissivity. The metasurface consists of an indium tin oxide (ITO)-patterned film, a polyethylene terephthalate (PET) substrate and an ITO backplane from the top downwards, with a total ultra-thin thickness of 1.6 mm. This design also allows the metasurface to have good optical transparency and flexibility. Based on phase cancellation and absorption, the metasurface can achieve a wideband RCS reduction of 10 dB from 10.6 to 19.4 GHz under normal incidence. When the metasurface is slightly cylindrically curved, an RCS reduction of approximately 10 dB can still be achieved from 11 to 19 GHz. The polarization and angular stability of the metasurface have also been verified. The filling rate of the top ITO-patterned film is 0.81, which makes the metasurface have a low theoretical IR emissivity of 0.24. Both simulation and experimental results have verified the excellent characteristics of the proposed checkerboard metasurface, demonstrating its great potential application in radar-IR bi-stealth.
Collapse
|
41
|
Li F, Yin A, Zhou Y, Liu T, Liu Q, Ruan W, Bu L. Stiffness Modulation in Flexible Rotational Triboelectric Nanogenerators for Dual Enhancement of Power and Reliability. NANOMATERIALS (BASEL, SWITZERLAND) 2024; 14:380. [PMID: 38392753 PMCID: PMC10892494 DOI: 10.3390/nano14040380] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/15/2024] [Revised: 02/14/2024] [Accepted: 02/15/2024] [Indexed: 02/24/2024]
Abstract
Rotational nanogenerators with flexible triboelectric layers have wide applications and high reliability. However, flexible materials cause a severe reduction in contact force and thus triboelectric output power. Unlike previous works devising complex auxiliary structures to solve this issue, this paper focuses on improving the contact material mechanics and proposes a stiffness modulation method. By introducing fine patterns to the contacting rotor-stator pairs, the effective elastic modulus was regulated from approximately 103 to 105 MPa, and the output voltage was modulated from approximately 24.39% to 375.87% compared to the non-patterned rotor-stator pairs, corresponding to a maximal a 14 times increase in output power. A maximal power density of 18.75 W/m2 was achieved on 10 MΩ resistance at 9.6 Hz, which is even beyond the power density of most rigid triboelectric interfaces. Moreover, high reliability could be maintained when the volume ratio of the horizontal patterns exceeded a threshold value of 33.5% as the stator and 63.6% as the rotor for a 0.5 mm linewidth. These results prove the efficacy of the stiffness modulation method for jointly achieving high output power and high reliability in flexible rotational triboelectric nanogenerators.
Collapse
|
42
|
Touitou E, Natsheh H. The Evolution of Emerging Nanovesicle Technologies for Enhanced Delivery of Molecules into and across the Skin. Pharmaceutics 2024; 16:267. [PMID: 38399321 PMCID: PMC10892037 DOI: 10.3390/pharmaceutics16020267] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2023] [Revised: 02/07/2024] [Accepted: 02/09/2024] [Indexed: 02/25/2024] Open
Abstract
This review focuses on nanovesicular carriers for enhanced delivery of molecules into and across the skin, from their design to recent emerging technologies. During the last four decades, several approaches have been used aiming to design new nanovesicles, some of them by altering the properties of the classic phospholipid vesicle, the liposome. Phospholipid nanovesicular systems, including the phospholipid soft vesicles as well as the non-phospholipid vesicular carries, are reviewed. The altered nanovesicles have served in the manufacture of various cosmetic products and have been investigated and used for the treatment of a wide variety of skin conditions. The evolution and recent advances of these nanovesicular technologies are highlighted in this review.
Collapse
|
43
|
Wang L, Liu S, Zhao W, Li J, Zeng H, Kang S, Sheng X, Wang L, Fan Y, Yin L. Recent Advances in Implantable Neural Interfaces for Multimodal Electrical Neuromodulation. Adv Healthc Mater 2024:e2303316. [PMID: 38323711 DOI: 10.1002/adhm.202303316] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2023] [Revised: 01/29/2024] [Indexed: 02/08/2024]
Abstract
Electrical neuromodulation plays a pivotal role in enhancing patient outcomes among individuals suffering from neurological disorders. Implantable neural interfaces are vital components of the electrical neuromodulation system to ensure desirable performance; However, conventional devices are limited to a single function and are constructed with bulky and rigid materials, which often leads to mechanical incompatibility with soft tissue and an inability to adapt to the dynamic and complex 3D structures of biological systems. In addition, current implantable neural interfaces utilized in clinical settings primarily rely on wire-based techniques, which are associated with complications such as increased risk of infection, limited positioning options, and movement restrictions. Here, the state-of-art applications of electrical neuromodulation are presented. Material schemes and device structures that can be employed to develop robust and multifunctional neural interfaces, including flexibility, stretchability, biodegradability, self-healing, self-rolling, or morphing are discussed. Furthermore, multimodal wireless neuromodulation techniques, including optoelectronics, mechano-electrics, magnetoelectrics, inductive coupling, and electrochemically based self-powered devices are reviewed. In the end, future perspectives are given.
Collapse
|
44
|
Zou X, Xue R, An Z, Li H, Zhang J, Jiang Y, Huang L, Wu W, Wang S, Hu GH, Li RKY, Zhao H. Recent Advances in Flexible CNC-Based Chiral Nematic Film Materials. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2024; 20:e2303778. [PMID: 37752783 DOI: 10.1002/smll.202303778] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/05/2023] [Revised: 08/30/2023] [Indexed: 09/28/2023]
Abstract
Cellulose nanocrystal (CNC) is a renewable resource derived from lignocellulosic materials, known for its optical permeability, biocompatibility, and unique self-assembly properties. Recent years have seen great progresses in cellulose nanocrystal-based chiral photonic materials. However, due to its inherent brittleness, cellulose nanocrystal shows limitations in the fields of flexible materials, optical sensors and food freshness testing. In order to solve the above limitations, attempts have been made to improve the flexibility of cellulose nanocrystal materials without destroying their structural color. Despite these progresses, a systematic review on them is lacking. This review aims to fill this gap by providing an overview of the main strategies and the latest research findings on the flexibilization of cellulose nanocrystal-based chiral nematic film materials (FCNM). Specifically, typical substances and methods used for their preparation are summarized. Moreover, different kinds of cellulose nanocrystal-based composites are compared in terms of flexibility. Finally, potential applications and future challenges of flexible cellulose nanocrystal-based chiral nematic materials are discussed, inspiring further research in this field.
Collapse
|
45
|
Overson DK, Darnell D, Robb F, Song AW, Truong TK. Flexible multi-purpose integrated RF/shim coil array for MRI and localized B 0 shimming. Magn Reson Med 2024; 91:842-849. [PMID: 37849021 PMCID: PMC10842526 DOI: 10.1002/mrm.29891] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2023] [Revised: 09/22/2023] [Accepted: 09/27/2023] [Indexed: 10/19/2023]
Abstract
PURPOSE To develop a flexible, lightweight, and multi-purpose integrated parallel reception, excitation, and shimming (iPRES) coil array that can conform to the subject's anatomy and perform MR imaging and localized B0 shimming in different anatomical regions with a high SNR, shimming performance, ease of positioning, and subject comfort. METHODS A four-channel flexible iPRES coil array was constructed by enabling RF and direct currents to flow on the same flexible coil elements for imaging and shimming, respectively. Shimming experiments were performed with the coil array wrapped around the knee or neck of healthy subjects to demonstrate its high shimming performance and versatility. Additionally, its SNR and shimming performance in the knee were compared to those obtained with the coil array wrapped around a larger rigid tube designed to fit most knee sizes. RESULTS Shimming with the coil array wrapped around the knee or neck resulted in an average reduction in B0 RMSE of 50.1% and 40.5% relative to first-order and second-order spherical harmonic shimming, respectively, and substantially reduced distortions in DWI images. In contrast, shimming the knee with the coil array wrapped around the rigid tube only provided a 29.6% reduction in B0 RMSE, whereas the SNR was reduced by 58.7%. CONCLUSION The flexible iPRES coil array can conform to different anatomical regions and perform imaging and localized B0 shimming with a higher SNR, shimming performance, ease of positioning, and comfort compared to a rigid iPRES coil array, which should be valuable for many applications throughout the human body.
Collapse
|
46
|
Xu R, Pan F, Chen J, Li J, Yang Y, Sun Y, Zhu X, Li P, Cao X, Xi J, Xu J, Yuan F, Dai J, Zuo C, Ding L, Dong H, Jen AKY, Wu Z. Optimizing the Buried Interface in Flexible Perovskite Solar Cells to Achieve Over 24% Efficiency and Long-Term Stability. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2024; 36:e2308039. [PMID: 37802505 DOI: 10.1002/adma.202308039] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/09/2023] [Revised: 09/22/2023] [Indexed: 10/10/2023]
Abstract
The buried interface of the perovskite layer has a profound influence on its film morphology, defect formation, and aging resistance from the outset, therefore, significantly affects the film quality and device performance of derived perovskite solar cells. Especially for FAPbI3 , although it has excellent optoelectronic properties, the spontaneous transition from the black perovskite phase to nonperovskite phase tends to start from the buried interface at the early stage of film formation then further propagate to degrade the whole perovskite. In this work, by introducing ─NH3 + rich proline hydrochloride (PF) with a conjugated rigid structure as a versatile medium for buried interface, it not only provides a solid α-phase FAPbI3 template, but also prevents the phase transition induced degradation. PF also acts as an effective interfacial stress reliever to enhance both efficiency and stability of flexible solar cells. Consequently, a champion efficiency of 24.61% (certified 23.51%) can be achieved, which is the highest efficiency among all reported values for flexible perovskite solar cells. Besides, devices demonstrate excellent shelf-life/light soaking stability (advanced level of ISOS stability protocols) and mechanical stability.
Collapse
|
47
|
Nan X, Kang T, Zhang Z, Wang X, Zhang J, Lei Y, Gao L, Cui J, Xu H. Flexible Symmetric-Defection Antenna with Bending and Thermal Insensitivity for Miniaturized UAV. MICROMACHINES 2024; 15:159. [PMID: 38276858 PMCID: PMC10818624 DOI: 10.3390/mi15010159] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/26/2023] [Revised: 01/13/2024] [Accepted: 01/19/2024] [Indexed: 01/27/2024]
Abstract
Flexible conformal-enabled antennas have great potential for various developable surface-built unmanned aerial vehicles (UAVs) due to their superior mechanical compliance as well as maintaining excellent electromagnetic features. However, it remains a challenge that the antenna holds bending and thermal insensitivity to negligibly shift resonant frequency during conformal attachment and aerial flight, respectively. Here, we report a flexible symmetric-defection antenna (FSDA) with bending and thermal insensitivity. By engraving a symmetric defection on the reflective ground, the radiated unit attached to the soft polydimethylsiloxane (PDMS) makes the antenna resonate at the ISM microwave band (resonant frequency = 2.44 GHz) and conformal with a miniaturized UAV. The antenna is also insensitive to both the bending-conformal attachment (20 mm < r < 70 mm) and thermal radiation (20~100 °C) due to the symmetric peripheral-current field along the defection and the low-change thermal effect of the PDMS, respectively. Therefore, the antenna in a non-bending state almost keeps the same impedance matching and radiation when it is attached to a cylinder-back of a UAV. The flexible antenna with bending and thermal insensitivity will pave the way for more conformal or wrapping applications.
Collapse
|
48
|
Chen T, Zheng X, Wang D, Zhu Y, Ouyang Y, Xue J, Wang M, Wang S, Ma W, Zhang C, Ma Z, Li S, Zuo L, Chen H. Delayed Crystallization Kinetics Allowing High-Efficiency All-Polymer Photovoltaics with Superior Upscaled Manufacturing. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2024; 36:e2308061. [PMID: 37734746 DOI: 10.1002/adma.202308061] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/09/2023] [Revised: 09/11/2023] [Indexed: 09/23/2023]
Abstract
Though encouraging performance is achieved in small-area organic photovoltaics (OPVs), reducing efficiency loss when evoluted to large-area modules is an important but unsolved issue. Considering that polymer materials show benefits in film-forming processability and mechanical robustness, a high-efficiency all-polymer OPV module is demonstrated in this work. First, a ternary blend consisting of two polymer donors, PM6 and PBQx-TCl, and one polymer acceptor, PY-IT, is developed, with which triplet state recombination is suppressed for a reduced energy loss, thus allowing a higher voltage; and donor-acceptor miscibility is compromised for enhanced charge transport, thus resulting in improved photocurrent and fill factor; all these contribute to a champion efficiency of 19% for all-polymer OPVs. Second, the delayed crystallization kinetics from solution to film solidification is achieved that gives a longer operation time window for optimized blend morphology in large-area module, thus relieving the loss of fill factor and allowing a record efficiency of 16.26% on an upscaled module with an area of 19.3 cm2 . Besides, this all-polymer system also shows excellent mechanical stability. This work demonstrates that all-polymer ternary systems are capable of solving the upscaled manufacturing issue, thereby enabling high-efficiency OPV modules.
Collapse
|
49
|
Li C, Qiu T, Li C, Cheng B, Jin M, Zhou G, Giersig M, Wang X, Gao J, Akinoglu EM. Highly Flexible and Acid-Alkali Resistant TiN Nanomesh Transparent Electrodes for Next-Generation Optoelectronic Devices. ACS NANO 2023; 17:24763-24772. [PMID: 37901960 DOI: 10.1021/acsnano.3c05211] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/31/2023]
Abstract
Transparent electrodes are vital for optoelectronic devices, but their development has been constrained by the limitations of existing materials such as indium tin oxide (ITO) and newer alternatives. All face issues of robustness, flexibility, conductivity, and stability in harsh environments. Addressing this challenge, we developed a flexible, low-cost titanium nitride (TiN) nanomesh transparent electrode showcasing exceptional acid-alkali resistance. The TiN nanomesh electrode, created by depositing a TiN coating on a naturally cracked gel film substrate via a sputtering method, maintains a stable electrical performance through thousands of bending cycles. It exhibits outstanding chemical stability, resisting strong acid and alkali corrosion, which is a key hurdle for current electrodes when in contact with acidic/alkaline materials and solvents during device fabrication. This, coupled with superior light transmission and conductivity (88% at 550 nm with a sheet resistance of ∼200 Ω/sq), challenges the reliance on conventional materials. Our TiN nanomesh electrode, successfully applied in electric heaters and electrically controlled thermochromic devices, offers broad potential beyond harsh environment applications. It enables alternative possibilities for the design and fabrication of future optoelectronics for advancements in this pivotal field.
Collapse
|
50
|
Liu L, Hu H, Pan W, Gao H, Song J, Feng X, Qu W, Wei W, Yang B, Wei H. Robust Organogel Scintillator for Self-healing and Ultra- flexible X-ray Imaging. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2023:e2311206. [PMID: 38104266 DOI: 10.1002/adma.202311206] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/25/2023] [Revised: 12/12/2023] [Indexed: 12/19/2023]
Abstract
Metal halide scintillators serve as promising candidates for X-ray detection due to their high attenuation coefficients, high light yields, and low-cost solution-processable characteristics. However, the issues of humidity/thermal quenching and mechanical fragility, remain obstacles to the broad and diversified development of metal halide scintillators. Here, this work reports a lead-free, water-stable, stretchable, and self-healing (ethylenebis-triphenylphosphonium manganese (II) bromide (C38 H34 P2 )MnBr4 organogel scintillator that meets X-ray imaging in complex scenarios. The robust organogel scintillator can be stretched with elongation up to 1300% while maintaining the scintillation properties. Activated by the dynamic hydrogen bonds and coordination bonds design, the organogel scintillator exhibits excellent self-healing properties at room temperature to alleviate the vignetting problem of the rigid scintillator films, the X-ray imaging resolution can reach 16.7 lp mm-1 . The organogel scintillator can also realize flexible and self-healing X-ray imaging in water, providing a design path for portable devices in harsh conditions.
Collapse
|