26
|
Wei A, Tang X, Yang W, Zhou J, Zhu W, Pan S. Efficacy of etonogestrel subcutaneous implants versus the levonorgestrel-releasing intrauterine system in the conservative treatment of adenomyosis. Open Med (Wars) 2024; 19:20240914. [PMID: 38584829 PMCID: PMC10996985 DOI: 10.1515/med-2024-0914] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2023] [Revised: 02/02/2024] [Accepted: 02/05/2024] [Indexed: 04/09/2024] Open
Abstract
To evaluate the clinical efficacy of etonogestrel subcutaneous implant (ENG-SCI) with that of the levonorgestrel-releasing intrauterine system (LNG-IUD) for adenomyosis treatment. A prospective randomized cohort study was conducted including 108 patients (50 patients in ENG-SCI group and 58 in the LNG-IUD group) with adenomyosis from January 2019 to July 2021. After 3 months of treatment, both ENG-SCI group and LNG-IUD group showed significant improvement in patients' visual analog scale, pictorial blood loss assessment chart (PBAC), and uterine volume (P < 0.05). The uterine volume of patients in LNG-IUD group decreased more significantly than that in the ENG-SCI group since 3 months of treatment. The PBAC score in the LNG-IUD group improved better than that in the ENG-SCI group since 6 months of treatment (P < 0.05). No significant difference in the occurrence rate of ideal vaginal bleeding patterns and the hemoglobin levels between the two groups was observed. The ENG-SCI group had a higher probability of weight gain and progesterone-related side effects (P < 0.05). Both ENG-SCI and LNG-IUD were effective in treatment of adenomyosis. However, LNG-IUD had a more significant effect in treating adenomyosis-related dysmenorrhea, excessive menstrual flow, anemia, and uterine enlargement, with relatively fewer side effects.
Collapse
|
27
|
van Hugten PPW, Jeuken RM, Asik EE, Oevering H, Welting TJM, van Donkelaar CC, Thies JC, Emans PJ, Roth AK. In vitro and in vivo evaluation of the osseointegration capacity of a polycarbonate-urethane zirconium-oxide composite material for application in a focal knee resurfacing implant. J Biomed Mater Res A 2024. [PMID: 38465895 DOI: 10.1002/jbm.a.37691] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2023] [Revised: 02/12/2024] [Accepted: 02/14/2024] [Indexed: 03/12/2024]
Abstract
Currently available focal knee resurfacing implants (FKRIs) are fully or partially composed of metals, which show a large disparity in elastic modulus relative to bone and cartilage tissue. Although titanium is known for its excellent osseointegration, the application in FKRIs can lead to potential stress-shielding and metal implants can cause degeneration of the opposing articulating cartilage due to the high resulting contact stresses. Furthermore, metal implants do not allow for follow-up using magnetic resonance imaging (MRI).To overcome the drawbacks of using metal based FKRIs, a biomimetic and MRI compatible bi-layered non-resorbable thermoplastic polycarbonate-urethane (PCU)-based FKRI was developed. The objective of this preclinical study was to evaluate the mechanical properties, biocompatibility and osteoconduction of a novel Bionate® 75D - zirconium oxide (B75D-ZrO2 ) composite material in vitro and the osseointegration of a B75D-ZrO2 composite stem PCU implant in a caprine animal model. The tensile strength and elastic modulus of the B75D-ZrO2 composite were characterized through in vitro mechanical tests under ambient and physiological conditions. In vitro biocompatibility and osteoconductivity were evaluated by exposing human mesenchymal stem cells to the B75D-ZrO2 composite and culturing the cells under osteogenic conditions. Cell activity and mineralization were assessed and compared to Bionate® 75D (B75D) and titanium disks. The in vivo osseointegration of implants containing a B75D-ZrO2 stem was compared to implants with a B75D stem and titanium stem in a caprine large animal model. After a follow-up of 6 months, bone histomorphometry was performed to assess the bone-to-implant contact area (BIC). Mechanical testing showed that the B75D-ZrO2 composite material possesses an elastic modulus in the range of the elastic modulus reported for trabecular bone. The B75D-ZrO2 composite material facilitated cell mediated mineralization to a comparable extent as titanium. A significantly higher bone-to-implant contact (BIC) score was observed in the B75D-ZrO2 implants compared to the B75D implants. The BIC of B75D-ZrO2 implants was not significantly different compared to titanium implants. A biocompatible B75D-ZrO2 composite approximating the elastic modulus of trabecular bone was developed by compounding B75D with zirconium oxide. In vivo evaluation showed an significant increase of osseointegration for B75D-ZrO2 composite stem implants compared to B75D polymer stem PCU implants. The osseointegration of B75D-ZrO2 composite stem PCU implants was not significantly different in comparison to analogous titanium stem metal implants.
Collapse
|
28
|
Emonde CK, Eggers ME, Wichmann M, Hurschler C, Ettinger M, Denkena B. Radiopacity Enhancements in Polymeric Implant Biomaterials: A Comprehensive Literature Review. ACS Biomater Sci Eng 2024; 10:1323-1334. [PMID: 38330191 PMCID: PMC10934286 DOI: 10.1021/acsbiomaterials.3c01667] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2023] [Revised: 01/17/2024] [Accepted: 01/18/2024] [Indexed: 02/10/2024]
Abstract
Polymers as biomaterials possess favorable properties, which include corrosion resistance, light weight, biocompatibility, ease of processing, low cost, and an ability to be easily tailored to meet specific applications. However, their inherent low X-ray attenuation, resulting from the low atomic numbers of their constituent elements, i.e., hydrogen (1), carbon (6), nitrogen (7), and oxygen (8), makes them difficult to visualize radiographically. Imparting radiopacity to radiolucent polymeric implants is necessary to enable noninvasive evaluation of implantable medical devices using conventional imaging methods. Numerous studies have undertaken this by blending various polymers with contrast agents consisting of heavy elements. The selection of an appropriate contrast agent is important, primarily to ensure that it does not cause detrimental effects to the relevant mechanical and physical properties of the polymer depending upon the intended application. Furthermore, its biocompatibility with adjacent tissues and its excretion from the body require thorough evaluation. We aimed to summarize the current knowledge on contrast agents incorporated into synthetic polymers in the context of implantable medical devices. While a single review was found that discussed radiopacity in polymeric biomaterials, the publication is outdated and does not address contemporary polymers employed in implant applications. Our review provides an up-to-date overview of contrast agents incorporated into synthetic medical polymers, encompassing both temporary and permanent implants. We expect that our results will significantly inform and guide the strategic selection of contrast agents, considering the specific requirements of implantable polymeric medical devices.
Collapse
|
29
|
Zhu M, Mao J, Fang J, Chen D. Risk factors for severe complications and salvage management in direct-to- implant immediate breast reconstruction: A retrospective study. Medicine (Baltimore) 2024; 103:e37365. [PMID: 38457600 PMCID: PMC10919468 DOI: 10.1097/md.0000000000037365] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/17/2023] [Revised: 02/01/2024] [Accepted: 02/02/2024] [Indexed: 03/10/2024] Open
Abstract
Controversies regarding the risk factors affecting direct-to-implant (DTI) immediate breast reconstruction still exist. This study aimed to evaluate the risk factors for severe complications in DTI breast reconstruction and explore potential salvage management strategies. We conducted a retrospective review of 238 patients (240 breasts) who underwent DTI immediate breast reconstruction between 2011 and 2020. Multivariate logistic regression analyses were used to identify the risk factors predicting severe complications. Seventeen (7.08%) reconstructed breasts experienced severe complications, of which only 5 were successfully salvaged through surgical revision, while the others failed and resulted in implant removal. Multivariate analyses demonstrated that mesh use [odds ratio (OR) = 4.054, 95% confidence interval: 1.376-11.945, P = .011] and post-mastectomy radiotherapy (odds ratio = 4.383, 95% confidence interval 1.142-16.819, P = .031) were independent predictors of severe complications. Mesh use and post-mastectomy radiotherapy for breast reconstruction increase the risk of severe complications. Despite positive surgical treatment, the successful salvage rate was poor.
Collapse
|
30
|
Huang C, Chiang SYV, Gawkrodger DJ. The contribution of metal allergy to the failure of metal alloy implants, with special reference to titanium: Current knowledge and controversies. Contact Dermatitis 2024; 90:201-210. [PMID: 38148670 DOI: 10.1111/cod.14481] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2023] [Revised: 11/26/2023] [Accepted: 11/29/2023] [Indexed: 12/28/2023]
Abstract
After almost three-quarters of a century during which contact dermatologists have often struggled to comprehend the relationship between metal allergy and failure of metal-alloy containing implant, it is possible to say that a relationship does exist, particularly for cobalt and chromium, but also for nickel. There is still debate as to whether allergy develops as a consequent of failure but thenceforth contributes to it, or whether sensitisation starts first and induces failure secondarily-opinion probably favours the first. Metal-on-polypropylene articulations were associated with few metal allergic problems but now are less favoured by orthopaedists due to plastic wear products causing osteolysis and pseudotumour formation through local inflammation. New metal alloys are regularly being introduced such that interested dermatologists need to stay on top of the situation. The jury is still out as to whether the recent favouring of titanium-containing alloys will confirm them to be more inert allergenically. Case reports do show some clinical reactions to titanium-containing implants and patch test series have inferred sometimes quite a high background rate of allergy, but interpretation must be tempered by the awareness that titanium salts on patch testing have a tendency to cause irritant reactions. Blood monitoring of metal ion values is now recommended in certain situations after joint replacement and increasing levels may be an indication that allergy with joint failure can develop, in which case patch testing is indicated, and suggested series are available. Predictive patch testing, whilst generally not recommended in the past, has been introduced into some protocols often by non-dermatologists, such that it is now needed for temporo-mandibular joint and Nuss bar insertion, and it can be anticipated that this may become more commonplace in the future. One of the major current deficits for patch testers is standardised guidance on which preparation or preparations to use for suspected titanium allergy. One suggestion is 0.5% titanium sulphate in petrolatum, though experience in at least one centre suggests the use of a battery of titanium salts might be desirable.
Collapse
|
31
|
Sinjab K, Sawant S, Ou A, Fenno JC, Wang HL, Kumar P. Impact of surface characteristics on the peri- implant microbiome in health and disease. J Periodontol 2024; 95:244-255. [PMID: 37665015 PMCID: PMC10909931 DOI: 10.1002/jper.23-0205] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2023] [Revised: 07/18/2023] [Accepted: 07/26/2023] [Indexed: 09/05/2023]
Abstract
BACKGROUND Because little is known about the impact of implant surface modifications on the peri-implant microbiome, we aimed to examine peri-implant communities in various surface types in order to better understand the impact of these surfaces on the development of peri-implantitis (PI). METHODS One hundred and six systemically healthy individuals with anodized (AN), hydroxyapatite-coated (HA), or sandblasted acid-etched (SLA) implants that were >6 months in function were recruited and categorized into health (H) or PI. Peri-implant biofilm was analyzed using 16S rRNA gene sequencing and compared between health/disease and HA/SLA/AN using community-level and taxa-level metrics. RESULTS Healthy implants did not demonstrate significant differences in clustering, alpha- or beta-diversity based on surface modification. AN and HA surfaces displayed significant differences between health and PI (p < 0.05); however, such a clustering was not evident with SLA (p > 0.05). AN and HA surfaces also differed in the magnitude and diversity of differences between health and PI. Six species belonging to the genera Shuttleworthia, Scardovia, and Prevotella demonstrated lower abundances in AN implants with PI, and 18 species belonging to the genera Fretibacterium, Tannerella, Treponema, and Fusobacterium were elevated, while in HA implants with PI, 20 species belonging to the genera Streptococcus, Lactobacillus, Veillonella, Rothia, and family Ruminococcaceae were depleted and Peptostreptococcaceae, Atopobiaceae, Veillonellaceae, Porphyromonadaceae, Desulfobulbaceae, and order Synergistales were enriched. CONCLUSIONS Within the limitations of this study, we demonstrate that implant surface can differentially modify the disease-associated microbiome, suggesting that surface topography must be considered in the multi-factorial etiology of peri-implant diseases.
Collapse
|
32
|
Ko CJ, Brooks Z, Veater R, Zhu S, Willson KW, Choung DJ. The Effect of Frontal Deformity at the Ankle Joint on Total Ankle Arthroplasty Revision Rate. J Foot Ankle Surg 2024; 63:145-150. [PMID: 37805097 DOI: 10.1053/j.jfas.2023.09.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/12/2022] [Revised: 09/20/2023] [Accepted: 09/28/2023] [Indexed: 10/09/2023]
Abstract
The presence of severe coronal plane deformity in the ankle joint is widely recognized as challenging to correct by total ankle joint arthroplasty alone, necessitating additional rearfoot fusion. The primary aim of this retrospective study was to investigate the potential associations between the presence or severity of coronal tibiotalar deformities and adverse outcomes after isolated total ankle arthroplasty, such as revisions and complications. The secondary aim was to analyze the potential associations between comorbidities, demographics, and implant types, and adverse outcomes. Our study's distinctive feature was its exclusive concentration on patients with deformities centralized in the ankle joint. Chart review was performed on 496 ankles in 456 patients who had a total ankle arthroplasty by 5 surgeons from 1/1/2010 to 12/31/2019. After exclusion and inclusion criteria were applied, total of 214 ankles in 210 patients were included for data analysis. At a mean follow-up period of 3 ± 2.0 years, our cohort had 15 (7.0%) revisions and 15 (7.0%) complications. Multivariable logistic regression model showed that the presence or severity of the coronal deformity was not significantly associated with incidences of revisions or complications. Female patients had significantly lower revision rate. Otherwise, the differences in age, race, body mass index, tobacco use, presence of diabetes, chronic kidney disease, atrial fibrillation, length of surgery, or type of implant were not significantly associated with incidences of revisions or complications. Further study could be performed to analyze the extent and duration that the coronal deformity correction is maintained after total ankle arthroplasty as well as the effect of each soft tissue procedure performed with the total ankle arthroplasty.
Collapse
|
33
|
Taniguchi Y, Koyanagi T, Takagi T, Kitanaka Y, Aoki A, Iwata T. Ridge Preservation and Augmentation Using a Carbonated Apatite Bone Graft Substitute: A Case Series. Dent J (Basel) 2024; 12:55. [PMID: 38534279 DOI: 10.3390/dj12030055] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2024] [Revised: 02/16/2024] [Accepted: 02/26/2024] [Indexed: 03/28/2024] Open
Abstract
The newly developed mineral carbonated apatite has recently been proposed as a bone graft material for bone regenerative treatment in implant therapy. This case series details the clinical and radiographic outcomes of ridge preservation and ridge augmentation using only carbonated apatite as bone graft material for implant treatment. Twenty patients (36 sites) who required bone regeneration and implant placement were retrospectively assessed. Simultaneous carbonated apatite implant placement was performed using the simultaneous ridge preservation or augmentation approach on 24 sites in 13 patients with sufficient bone quantity for primary stabilization based on preoperative evaluation results. A staged ridge preservation or augmentation approach was used for the remaining 12 sites in seven patients with insufficient bone quantity. The mean regenerated bone height for each treatment method was as follows: simultaneous preservation, 7.4 ± 3.3 mm; simultaneous augmentation, 3.6 ± 2.3 mm; staged preservation, 7.2 ± 4.5 mm; and staged augmentation, 6.1 ± 2.7 mm. The mean regenerated bone width for each treatment method was as follows: simultaneous preservation, 6.5 ± 2.9 mm; simultaneous augmentation, 3.3 ± 2.5 mm; staged preservation, 5.5 ± 1.7 mm; and staged augmentation, 3.5 ± 1.9 mm. Ultimately, the use of carbonated apatite alone as a bone graft material in implant therapy resulted in stable and favorable bone regeneration.
Collapse
|
34
|
Katayama ES, Durisek GR, Bustamante GC, Barry LW, Wilson S, Barnett JS, Borin M, Stevens A, Patel AV, Bishop JY, Cvetanovich GL, Rauck RC. The role of body mass index on survivorship and clinical outcomes in total shoulder arthroplasty. J Shoulder Elbow Surg 2024:S1058-2746(24)00145-9. [PMID: 38423249 DOI: 10.1016/j.jse.2024.01.031] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/05/2023] [Revised: 01/06/2024] [Accepted: 01/08/2024] [Indexed: 03/02/2024]
Abstract
BACKGROUND Increased body mass index (BMI) is a potential risk factor for poorer outcomes and complications. However, the influence of BMI on the long-term outcomes of anatomic and reverse total shoulder arthroplasty (aTSA and rTSA) remains to be fully elucidated. METHODS Institutional records were queried to identify patients who underwent primary TSA between 2009-2020 with a minimum of 2 years of clinical follow-up. Retrospective review was performed to collect demographics, comorbidity status, and range of motion and strength measurements in forward elevation, external rotation, and internal rotation. Patients were called to obtain patient reported outcomes. Patients were stratified into 3 cohorts, by BMI: underweight or normal weight (U/NW, BMI≤25), overweight (OW, 2530). RESULTS Among 466 TSA patients, 245 underwent aTSA while 221 underwent rTSA. In the aTSA cohort, 40 were classified as U/NW, 72 as OW, and 133 as obese. Comparatively, the rTSA cohort was composed of 33 U/NW, 79 OW, and 209 obese patients. aTSA and rTSA patients had an average follow-up of 5.8±3.2 years and 4.5±2.3 years, respectively. No differences were found in age at surgery for the aTSA group (U/NW: 65.2±7.9 vs obese: 61.9±8.9 years; p=0.133), however, in the rTSA cohort, BMI was found to be inversely related to age at surgery (U/NW: 72.4±8.8 vs obese: 65.7±8.3 years; p<0.001). Across all BMI cohorts, patients saw great improvement in range of motion and strength. Postoperative patient reported outcomes for TSA did not vary by BMI in SANE, SST, VAS pain, and ASES scores. There was no significant difference in survival rates at 10-year follow-up in aTSA (U/NW: 95.8% vs obese: 93.2%; p=0.753) or rTSA (U/NW: 94.7% vs obese: 94.5%; p=0.791). CONCLUSION With dramatic improvements in range of motion, minimal differences in patient reported outcomes, and high rates of implant survival, TSA is a safe and effective treatment option for all patients, including for overweight and obese patients.
Collapse
|
35
|
Liu G, Sun H, Shi B, Xia H, Wu T. Rat Peri- implantitis Models: A Systematic Review and Meta-analysis. Int J Oral Maxillofac Implants 2024; 39:65-78. [PMID: 38416001 DOI: 10.11607/jomi.10424] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/29/2024] Open
Abstract
PURPOSE To review experimental peri-implantitis studies using rat models and summarize different peri-implantitis induction techniques and evaluate their effectiveness. MATERIALS AND METHODS Electronic searches were conducted by two independent examiners to address the following issues. Meta-analyses explored the marginal bone loss (MBL) of four types of peri-implantitis induction methods in rats. The detailed induction tactics-such as the implant design, implant size, surgical process, time cost, induction methods, and endpoint measurements-were summarized. RESULTS Of the 18 included studies, 38.9% of the studies placed implants at the maxillary first molar, and 44.4% placed them at the alveolar ridge region anterior to the maxillary first molar. As for the induction method, the numbers of published studies on ligature methods, bacterial inoculation, and bacterial lipopolysaccharide inoculation were equally high among all selected studies. The total implant survival rate at the end was 160 out of 213 implants (75.11%). Eight studies with high pooled heterogeneity (I2 = 98, P < .01) in the meta-analysis reported an overall MBL (μ-CT) of 0.47 mm (95% CI = 0.14 to 0.81). A subgroup analysis estimated an MBL of 0.31 mm (95% CI = 0.12 to 0.50) for bacterial inoculation and 0.66 mm (95% CI = 0.07 to 1.26) for the ligature method. Histopathologic analysis revealed that peri-implantitis in rats was similar to peri-implantitis lesions in humans. CONCLUSIONS Implant placement at the maxillary first molar with bacterial inoculation and the silk ligature method to build peri-implantitis rat models is reliable to use for research on peri-implantitis.
Collapse
|
36
|
Holt MW, Robinson EC, Shlobin NA, Hanson JT, Bozkurt I. Intracortical brain-computer interfaces for improved motor function: a systematic review. Rev Neurosci 2024; 35:213-223. [PMID: 37845811 DOI: 10.1515/revneuro-2023-0077] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2023] [Accepted: 09/23/2023] [Indexed: 10/18/2023]
Abstract
In this systematic review, we address the status of intracortical brain-computer interfaces (iBCIs) applied to the motor cortex to improve function in patients with impaired motor ability. This study followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) 2020 Guidelines for Systematic Reviews. Risk Of Bias In Non-randomized Studies - of Interventions (ROBINS-I) and the Effective Public Health Practice Project (EPHPP) were used to assess bias and quality. Advances in iBCIs in the last two decades demonstrated the use of iBCI to activate limbs for functional tasks, achieve neural typing for communication, and other applications. However, the inconsistency of performance metrics employed by these studies suggests the need for standardization. Each study was a pilot clinical trial consisting of 1-4, majority male (64.28 %) participants, with most trials featuring participants treated for more than 12 months (55.55 %). The systems treated patients with various conditions: amyotrophic lateral sclerosis, stroke, spinocerebellar degeneration without cerebellar involvement, and spinal cord injury. All participants presented with tetraplegia at implantation and were implanted with microelectrode arrays via pneumatic insertion, with nearly all electrode locations solely at the precentral gyrus of the motor cortex (88.88 %). The development of iBCI devices using neural signals from the motor cortex to improve motor-impaired patients has enhanced the ability of these systems to return ability to their users. However, many milestones remain before these devices can prove their feasibility for recovery. This review summarizes the achievements and shortfalls of these systems and their respective trials.
Collapse
|
37
|
Wang C, Duan N, Li Z, Ma T, Zhang K, Wang Q, Huang Q. Biomechanical evaluation of a new intramedullary nail compared with proximal femoral nail antirotation and InterTAN for the management of femoral intertrochanteric fractures. Front Bioeng Biotechnol 2024; 12:1353677. [PMID: 38464545 PMCID: PMC10920256 DOI: 10.3389/fbioe.2024.1353677] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2023] [Accepted: 02/19/2024] [Indexed: 03/12/2024] Open
Abstract
Purpose: Surgical treatment is the main treatment method for femoral intertrochanteric fractures (FIFs), however, there are lots of implant-related complications after surgery. Our team designed a new intramedullary nail (NIN) to manage such fractures. The purpose of this study was to introduce this new implant and compare it with proximal femoral nail antirotation (PFNA) and InterTAN for treating FIFs. Methods: An AO/OTA 31-A1.3 FIF model was built and three fixation models were created via finite element method, comprising PFNA, InterTAN, and the NIN. Vertical, anteroposterior (A-P) bending, and torsional loads were simulated and applied to the three fixation models. Displacement and stress distribution were monitored. In order to compare PFNA and the NIN deeply, finite element testing was repeated for five times in vertical load case. Results: The finite element analysis (FEA) data indicated that the NIN possessed the most outstanding mechanical properties among the three fixation models. The NIN model had lower maximal stress at implants compared to PFNA and InterTAN models under three load conditions. The trend of maximal stress at bones was similar to that of maximal stress at implants. Besides, the NIN model showed smaller maximal displacement compared with PFNA and InterTAN models under vertical, A-P bending, and torsional load cases. The trend for maximal displacement of fracture surface (MDFS) was almost identical with that of maximal displacement. In addition, there was significant difference between the PFNA and NIN groups in vertical load case (p < 0.05). Conclusion: Compared with PFNA and InterTAN, the NIN displayed the best mechanical properties for managing FIFs, including the lowest von Mises stress at implants and bones, and the smallest maximal displacement and MDFS under vertical, A-P bending, and torsional load cases. Therefore, this study might provide a new choice for patients with FIFs.
Collapse
|
38
|
Horton LM, Depenbusch BE, Schroeder TC, Pendell DL, Streeter MN, Hutcheson JP, Renter DG. Impacts of economic factors influencing net returns of beef feedlot heifers administered two implant programs and fed for differing days-on-feed from pooled randomized controlled trials. Transl Anim Sci 2024; 8:txae021. [PMID: 38585170 PMCID: PMC10999156 DOI: 10.1093/tas/txae021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2023] [Accepted: 02/16/2024] [Indexed: 04/09/2024] Open
Abstract
The objective of this research was to evaluate the effects of two implant programs and differing days-on-feed (DOF) on net returns of beef feedlot heifers using sensitivity analyses of key economic factors. Crossbred beef heifers [n = 10,583; initial weight 315 kg (± 20.1 SD)] were enrolled across three trials (one Kansas, two Texas feedlot trials). Heifers were blocked by arrival and randomly allocated to one of six pens, resulting in a total of 144 pens and 24 blocks. Pen was randomly assigned to treatment as a 2 × 3 factorial. Implant programs were: IH + 200-Revalor-IH at initial processing, and a terminal implant after approximately 90 DOF (Revalor-200), or, XH-a single implant at initial processing (Revalor-XH). The DOF treatments were: heifers fed to a standard baseline endpoint (BASE) or heifers fed for an additional + 21 or + 42 d beyond BASE. Pen-level partial budgets were used for economic sensitivity analyses, which varied price points of single pricing components with all other components fixed. Variable components were live-fed cattle prices, base carcass prices (i.e., dressed), Choice-Select spread (CS-spread), and feed and yardage prices (FYP). For each, a Low, Mid-Low, Middle, Mid-High, and High price was chosen. Linear mixed models were fit for statistical analyses (α = 0.05). There were no significant two-way interactions (P-values ≥ 0.14). Regardless of the variable component evaluated, XH heifers had poorer net returns than IH + 200 at all prices (P ≤ 0.04). Selling live, the + 21 and (or) + 42 heifers had lower net returns than BASE at every fed cattle price point (P < 0.01). Selling dressed, the + 21 and (or) + 42 heifers had lower returns than BASE at Low, Mid-Low, and Middle fed cattle base prices (P < 0.01); there were no significant DOF differences at Mid-High, or High prices (P ≥ 0.24). Net returns were lower for + 42 than BASE at all CS-spreads (P ≤ 0.03), while BASE and + 21 did not differ significantly. Longer DOF had lower net returns than BASE when selling live at every FYP (P < 0.01) except at the Low price (P = 0.14). Selling dressed, there was no significant effect of DOF at Low or Mid-Low FYP (P ≥ 0.11); conversely, extended DOF had lower net returns than BASE at Middle, Mid-High, and High FYP (P < 0.01). Overall, there was minimal economic evidence to support extending feedlot heifer DOF beyond the BASE endpoint, and when feeding longer, larger reductions in return were observed when marketing live as opposed to dressed.
Collapse
|
39
|
Chao D, Komatsu K, Matsuura T, Cheng J, Stavrou SC, Jayanetti J, Chang TL, Ogawa T. Human Gingival Fibroblast Growth and Function in Response to Laser-Induced Meso-and Microscale Hybrid Topography on Dental Implant Healing Abutments. Int J Oral Maxillofac Implants 2024; 0:4982715. [PMID: 38358908 DOI: 10.11607/jomi.10745] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/17/2024] Open
Abstract
PURPOSE Laser-created titanium surface topographies enhance soft tissue attachment and implant stability. However, knowledge about the underlying mechanisms governing the tissue-level reaction is lacking. The objective of this study was to examine the behavior and function of human gingival fibroblasts growing on healing abutments with or without laser-textured topography. MATERIALS AND METHODS Human primary gingival connective tissue fibroblasts were cultured on healing abutments with machined or laser-textured (Laser-Lok, BioHorizons) surfaces. Cellular and molecular responses were evaluated by cell density assay (WST-1), fluorescence microscopy, qRT-PCR, and detachment test. RESULTS The machined surface showed mono-directional traces and scratches from milling, whereas the laser-textured surface showed a distinct morphology consisting of mono-directional meso-scale channels (15 μm pitch) and woven, oblique micro-ridges formed within the channel. There were no differences in initial fibroblast attachment, subsequent fibroblast proliferation, nor collagen production between the machined and laser-textured surfaces. Fibroblasts growing on laser-textured surface spread mono-directionally along the meso-channels, while cells growing on machined surfaces spread randomly. Fibroblasts on laser-textured surfaces were 1.8-times more resistant to detachment than those on machined surfaces. An adhesive glycoprotein (fibronectin) and trans-membrane adhesion linker gene (integrin beta-1) were upregulated on laser-textured surfaces. CONCLUSIONS The increased fibroblast retention, uniform growth, increased transcription of cell adhesion proteins compellingly explain the enhanced tissue-level response to laser-created, hybrid textured titanium surfaces. These results provide a cellular and molecular rationale for the tissue reaction to this unique surface and support its extended use from implant fixtures and healing abutments to diverse prosthetic components where enhanced soft tissue responses would be desirable.
Collapse
|
40
|
Ocadiz-Ruiz R, Decker JT, Griffin K, Tan ZM, Domala NK, Jeruss JS, Shea LD. Human Breast Cancer Cell Lines Differentially Modulate Signaling from Distant Microenvironments, Which Reflects Their Metastatic Potential. Cancers (Basel) 2024; 16:796. [PMID: 38398186 PMCID: PMC10887178 DOI: 10.3390/cancers16040796] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2023] [Revised: 02/12/2024] [Accepted: 02/13/2024] [Indexed: 02/25/2024] Open
Abstract
Metastasis is the stage at which the prognosis substantially decreases for many types of cancer. The ability of tumor cells to metastasize is dependent upon the characteristics of the tumor cells, and the conditioning of distant tissues that support colonization by metastatic cells. In this report, we investigated the systemic alterations in distant tissues caused by multiple human breast cancer cell lines and the impact of these alterations on the tumor cell phenotype. We observed that the niche within the lung, a common metastatic site, was significantly altered by MDA-MB-231, MCF7, and T47 tumors, and that the lung microenvironment stimulated, to differing extents, an epithelial-to-mesenchymal transition (EMT), reducing proliferation, increasing transendothelial migration and senescence, with no significant impact on cell death. We also investigated the ability of an implantable scaffold, which supports the formation of a distant tissue, to serve as a surrogate for the lung to identify systemic alterations. The scaffolds are conditioned by the primary tumor similarly to the lung for each tumor type, evidenced by promoting a pro-EMT profile. Collectively, we demonstrate that metastatic and non-metastatic breast cancers condition distant tissues, with distinct effects on tumor cell responses, and that a surrogate tissue can distinguish the metastatic potential of human breast cancer cell lines in an accessible site that avoids biopsy of a vital organ.
Collapse
|
41
|
Hrovat M, Kolandaivelu A, Wang Y, Gunderman A, Halperin HR, Chen Y, Schmidt EJ. Balanced-force shim system for correcting magnetic-field inhomogeneities in the heart due to implanted cardioverter defibrillators. Front Med (Lausanne) 2024; 11:1225848. [PMID: 38414618 PMCID: PMC10897050 DOI: 10.3389/fmed.2024.1225848] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2023] [Accepted: 01/22/2024] [Indexed: 02/29/2024] Open
Abstract
Background In the US, 1.4 million people have implanted ICDs for reducing the risk of sudden death due to ventricular arrhythmias. Cardiac MRI (cMR) is of particular interest in the ICD patient population as cMR is the optimal imaging modality for distinguishing cardiac conditions that predispose to sudden death, and it is the best method to plan and guide therapy. However, all ICDs contain a ferromagnetic transformer which imposes a large inhomogeneous magnetic field in sections of the heart, creating large image voids that can mask important pathology. A shim system was devised to resolve these ICD issues. A shim coil system (CSS) that corrects ICD artifacts over a user-selected Region-of-Interest (ROI), was constructed and validated. Methods A shim coil was constructed that can project a large magnetic field for distances of ~15 cm. The shim-coil can be positioned safely anywhere within the scanner bore. The CSS includes a cantilevered beam to hold the shim coil. Remotely controlled MR-conditional motors allow 2 mm-accuracy three-dimensional shim-coil position. The shim coil is located above the subjects and the imaging surface-coils. Interaction of the shim coil with the scanner's gradients was eliminated with an amplifier that is in a constant current mode. Coupling with the scanners' radio-frequency (rf) coils, was reduced with shielding, low-pass filters, and cable shield traps. Software, which utilizes magnetic field (B0) mapping of the ICD inhomogeneity, computes the optimal location for the shim coil and its corrective current. ECG gated single- and multiple-cardiac-phase 2D GRE and SSFP sequences, as well as 3D ECG-gated respiratory-navigated IR-GRE (LGE) sequences were tested in phantoms and N = 3 swine with overlaid ICDs. Results With all cMR sequences, the system reduced artifacts from >100 ppm to <25 ppm inhomogeneity, which permitted imaging of the entire left ventricle in swine with ICD-related voids. Continuously acquired Gradient recalled echo or Steady State Free Precession images were used to interactively adjust the shim current and coil location. Conclusion The shim system reduced large field inhomogeneities due to implanted ICDs and corrected most ICD-related image distortions. Externally-controlled motorized translation of the shim coil simplified its utilization, supporting an efficient cardiac MRI workflow.
Collapse
|
42
|
Chen T, Jinno Y, Atsuta I, Tsuchiya A, Obinata S, Iimori R, Kimura T, Ayukawa Y. Synergistic Effect of Nano Strontium Titanate Coating and Ultraviolet C Photofunctionalization on Osteogenic Performance and Soft Tissue Sealing of poly(ether-ether-ketone). ACS Biomater Sci Eng 2024; 10:825-837. [PMID: 38267012 PMCID: PMC10866145 DOI: 10.1021/acsbiomaterials.3c01684] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2023] [Revised: 12/19/2023] [Accepted: 01/04/2024] [Indexed: 01/26/2024]
Abstract
This study aimed to evaluate the bioactivity of poly(ether ether ketone) (PEEK) after surface modification by persistent photoconductive strontium titanate (SrTiO3) magnetron sputtering and ultraviolet (UV) C irradiation. According to the different modifications, the PEEK specimens were randomly divided into five groups (n = 38/group): PEEK, Sr100-PEEK, Sr200-PEEK, UV/PEEK, and UV/Sr200-PEEK. Then, the specimens of Sr100-PEEK and Sr200-PEEK groups were, respectively, coated with 100 and 200 nm thickness photocatalyst SrTiO3 on the PEEK surface by magnetron sputtering. Subsequently, UV-C light photofunctionalized the specimens of PEEK and Sr200-PEEK groups to form UV/PEEK and UV/Sr200-PEEK groups. The specimens were characterized by a step meter, scanning electron microscopy (SEM), atomic force microscopy (AFM), energy dispersive X-ray spectroscopy (EDX), and a water contact angle meter. The release test of the Sr ion was performed by inductively coupled plasma mass spectrometry (ICP-MS). In vitro study, osteogenic activity (MC3T3-E1 osteoblast-like cells) and epithelial and connective tissue attachment (gingival epithelial cells GE1 and fibroblasts NIH3T3) were analyzed in five groups. Surface morphology of the specimens was changed after coating, and the Sr content on the Sr-PEEK surface was increased with increasing coating thickness. In addition, the contact angle was increased significantly after magnetron sputtering. After UV-C photofunctionalization, the content of surface elements changed and the contact angle was decreased. The release of Sr ion was sustained, and the final cumulative release amount did not exceed the safety limit. In vitro experiments showed that SrTiO3 improved the cell activity of MC3T3-E1 and UV-C irradiation further enhanced the osteogenic performance of PEEK. Besides, UV-C irradiation also significantly promoted the cell viability, development, and expression of adhesion proteins of GE1 and NIH3T3 on PEEK. The present investigation demonstrated that nano SrTiO3 coating with UV-C photofunctionalization synergistically enhanced the osteogenic properties and soft tissue sealing function of PEEK in vitro.
Collapse
|
43
|
Hallab NJ, Hallab SR, Alexander A, Pourzal R. Characterization of residual debris on packaged hip arthroplasty stems demonstrates the dominance of less than 10 μm sized particulate: Updated USP788 guidelines for orthopedic implants. J Biomed Mater Res B Appl Biomater 2024; 112:e35387. [PMID: 38340016 DOI: 10.1002/jbm.b.35387] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2023] [Revised: 10/19/2023] [Accepted: 01/27/2024] [Indexed: 02/12/2024]
Abstract
Past evaluation of particle contamination on packaged implants has typically been conducted using US Pharmacopeia (USP) 788, a 1970s pharmaceutical guideline created to evaluate contaminant particles in injectable fluids and syringes. Our objective was to reestablish relevant acceptance criteria for residual orthopedic and other implant debris, including smaller particles (i.e., <10 μm in diameter). Packaged total hip arthroplasty (THA) titanium (Ti6Al4V)-alloy femoral stems were used (hydroxyapatite [HA]-coated and non-coated stems). Short-term ultrasonication and longer-term 24-hour soak/agitation methods were used to elute surface-bound contaminant particles, and released particles were analyzed via scanning electron microscopy, energy-dispersive x-ray analysis, image analysis, and particle characterization. For HA-coated THA-stems, >99% of eluted particles were calcium phosphate. For plain non-coated THA-stems, >99% of eluted particles were titanium-alloy-based. The number-based median size of particles in both groups was approximately 1.5 μm in diameter despite being composed of different materials. The total volume of particulate removed from HA-coated stems was 0.037 mm3 (671 × 103 particles total), which was approximately >50-fold more volume than that on plain non-coated stems at 0.0006 mm3 (89 × 103 particles total). Only non-coated THA stems passed reestablished USP788 acceptance criteria, compared by using equivalent total volumes of contaminant particulate within new and legacy guideline ranges of >10 and >25 μm ECD, that is, <1.0 × 107 particles for <1 μm diameter in size, <600,000 for <1-10 μm, <6000 for 10-25 μm and <600 for >25 μm. These results fill a knowledge gap on how much residual debris can be expected to exist on packaged implants and can be used as a basis for updating acceptance criteria (i.e., termed USP788-Implant [USP788-I]). Residual implant particulate assessment is critical given the increasing implant complexity and new manufacturing techniques (e.g., additive manufacturing).
Collapse
|
44
|
So E, Wilson M, Chu AK, Thompson JM, Prissel MA. Incidence of Nonunion of the First Metatarsophalangeal Joint Arthrodesis After Failed Implant Arthroplasty: A Systematic Review. Foot Ankle Spec 2024; 17:78-86. [PMID: 37165627 DOI: 10.1177/19386400231169364] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
Joint arthroplasty of the first metatarsophalangeal (MTP) joint is an accepted surgical option for patients with hallux rigidus. However, this procedure has been reported to have a high complication rate and unpredictable survivorship. Implant arthroplasty failure is a devastating complication that results in significant osseous defect with altered biomechanics of the foot. Commonly, salvage options are limited to arthrodesis with bone grafting. However, outcomes are rarely reported. The purpose of this study is to investigate the fusion rates of first metatarsophalangeal joint arthrodesis after conversion from failed implant arthroplasty. A systematic review of electronic databases to find reports of conversion arthrodesis after failed implant arthroplasty was performed. Six studies involving a total of 76 patients with a weighted mean age of 54.9 met the inclusion criteria. Out of the 6 included articles, the nonunion rate was 16.5% at a weighted mean follow-up of 48.1 months. The nonunion rate in the current report is higher than reported nonunion rates of primary arthrodesis. More prospective studies with consistent and standard outcome measures are needed to further determine the success rate of this salvage procedure.Levels of Evidence: 4, Systematic Review of Level 4 Studies.
Collapse
|
45
|
Singh A, Muthukumarswamy A, Attokaran G, Garhnayak M, Garhnayak L, Gopal L, Reddy N. Clinical and CBCT Assessment of Role of Bisphosphonate on Osteotomy Site and Implant Surface. JOURNAL OF PHARMACY AND BIOALLIED SCIENCES 2024; 16:S140-S142. [PMID: 38595363 PMCID: PMC11000954 DOI: 10.4103/jpbs.jpbs_426_23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2023] [Revised: 07/29/2023] [Accepted: 07/30/2023] [Indexed: 04/11/2024] Open
Abstract
Objectives To assess the role of bisphosphonate on osteotomy site and implant surface. Materials and Methods Twenty patients with adequate width and height of edentulous space and a single missing posterior tooth between the ages of 25 and 55 were incorporated in this research. Ten participants received implant therapy alone; the other ten patients received implant therapy and bisphosphonate application to osteotomy site and the implant surface. Result Changes in the crestal bone level were seen in both the study and control groups. At 1 year, crestal bone loss was less in the bisphosphonate-treated group than in the control group. Conclusion The quantity of crestal bone loss was reduced when bisphosphonate (sodium alendronate) was applied locally near the implant and osteotomy site.
Collapse
|
46
|
Anthis AHC, Kilchenmann S, Murdeu M, LeValley PJ, Wolf M, Meyer C, Cipolato O, Tibbitt MW, Rosendorf J, Liska V, Rduch T, Herrmann IK. Reversible Mechanical Contraception and Endometriosis Treatment Using Stimuli-Responsive Hydrogels. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2024:e2310301. [PMID: 38298130 DOI: 10.1002/adma.202310301] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/05/2023] [Revised: 12/22/2023] [Indexed: 02/02/2024]
Abstract
Female sterilization via fallopian tube ligation is a common procedure; However, after the operation, over 10% of women seek re-fertilization, which is frequently unsuccessful. In addition, there is evidence that fallopian tubes contribute to the spread of endometriotic tissue as they serve as channels for proinflammatory media entering the abdominal cavity via retrograde menstruation. Here, stimuli-degradable hydrogel implants are presented for the functional, biocompatible, and reversible occlusion of fallopian tubes. The hydrogel implants, designed with customized swelling properties, mechanically occlude fallopian tubes in a high-performance manner with burst pressures reaching 255-558 mmHg, exceeding normal abdominal pressures (95 mmHg). Their damage-free removal can be achieved within 30 min using near-visible UV light or a glutathione solution, employing a method akin to standard fallopian tube perfusion diagnostics. Ultrasound-guided implant placement is demonstrated using a clinical hysteroscope in a human-scale uterus model and biocompatibility in a porcine in vivo model. Importantly, the prevention of live sperm as well as endometrial cell passage through blocked fallopian tubes is demonstrated. Overall, a multifunctional system is presented that constitutes a possible means of on-demand, reversible contraception along with the first-ever mechanical approach to abdominal endometriosis prevention and treatment.
Collapse
|
47
|
Bhargava A, Saigal S, Chatterjee S, Chandrasekaram K, Khurshid G, Sandou GP, Singh V. Evaluation of Type, Nature, and Prevalence of Common Oral Pathology Lesions Involving Periodontium and Implant in Patients of Tertiary Level Dental Hospital in Hazaribagh City, Jharkhand. JOURNAL OF PHARMACY AND BIOALLIED SCIENCES 2024; 16:S115-S117. [PMID: 38595501 PMCID: PMC11001043 DOI: 10.4103/jpbs.jpbs_403_23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2023] [Revised: 07/24/2023] [Accepted: 07/24/2023] [Indexed: 04/11/2024] Open
Abstract
Background Evaluation of type, nature, and prevalence of common oral pathology lesions involving periodontium and implant in patients of tertiary level dental hospital in Hazaribagh City, Jharkhand. Materials and Methods A total of 2467 people were requested to take part in the oral examination. The current study cohort was made up of the 62.4% of the initial subgroup who participated in the clinical oral examination and granted their agreement for the use of the data. Between January 2023 and June 2023, the clinical oral examination was completed. Results No changes were observed in 89.6% of study participants. 88.2% males had no changes while 90.4% females had no changes. Normal variations were observed in 3.4% of study participants. 4.3% males had normal variations while 2.7% females had normal variations. Infectious oral pathology was observed in 3.3% of study participants. 2.4% males had infectious oral pathology while 3.2% females had infectious oral pathology Ulcerative lesions were observed in 4.1% of study participants. 3.6% males had ulcerative lesions while 2.4% females had ulcerative lesions. White lesions were observed in 6.7% of study participants. 8.2% males had white lesions while 5.6% females had white lesions. Conclusion This study provided a detailed evaluation of type, nature, and prevalence of different oral pathology lesions focusing on periodontium and implant.
Collapse
|
48
|
Doty J, Murphy GA, Bohay D, Fortin P, Vora A, Strasser N, Friscia D, Newton W, Gross CE. Two-Year Survivorship and Patient-Reported Outcomes of a Prospectively Enrolled Cohort of INFINITY Total Ankle Arthroplasties. Foot Ankle Int 2024; 45:150-157. [PMID: 38140701 DOI: 10.1177/10711007231212484] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/24/2023]
Abstract
BACKGROUND The INFINITY total ankle implant is a widely and successfully used option for total ankle arthroplasty. The purpose of this study is to assess the 2-year survivorship, complication rates, patient-reported outcomes, and radiologic findings of prospectively enrolled patients undergoing a fixed-bearing total ankle arthroplasty (TAA). This study sought to determine if factors such as traditional vs patient-specific instrumentation, preoperative degree of arthritis, deformity, or etiology of arthritis impact surgical or clinical outcomes. METHODS A total of 143 prospectively enrolled patients (148 ankles) underwent TAA with a fixed-bearing total ankle implant between 2017 and 2019 at 9 different institutions by 9 different surgeons. A total of 116 completed 2-year follow-up. Patients were stratified by instrumentation used, degree of preoperative deformity, the Canadian Orthopaedic Foot and Ankle Society (COFAS) grading system, and etiology of arthritis. Outcomes used included implant survivorship and adverse events within 2 years of surgery. Additionally, patient-reported outcomes and radiographs were collected at 6-month, 1-year, and 2-year postoperatively. PROMs used included Ankle Osteoarthritis Score (AOS), Patient-Reported Outcomes Measurement Information System (PROMIS) global health score, the Foot and Ankle Outcome Score (FAOS), and patient satisfaction (rated from excellent to poor). RESULTS Implant survivorship at 2 years was 97.79%. There were 17 reoperations (11.5%), with 4 of the implants requiring revision (2.7%). Significant improvements in all PROMs were observed among all subgroups at all postoperative time points without significant variation between subgroups. Patients classified as COFAS type 2 arthritis preoperatively demonstrated significantly more improvement in FAOS Total Symptom Score at the 1- and 2-year measurements than COFAS type 3 patients at both time points. CONCLUSION Total ankle arthroplasty with a fixed-bearing implant system is a safe and reliable treatment option for patients with end-stage arthritis regardless of degree of deformity or COFAS grading. LEVEL OF EVIDENCE Level II, prospective cohort study.
Collapse
|
49
|
Hashemi S, Tabatabaei S, Baghaei K, Fathi A, Atash R. Long-Term Clinical Outcomes of Single Crowns or Short Fixed Partial Dentures Supported by Short (≤6 mm) Dental Implants: A Systematic Review. Eur J Dent 2024; 18:97-103. [PMID: 37591286 PMCID: PMC10959620 DOI: 10.1055/s-0043-1771028] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/19/2023] Open
Abstract
Long-term clinical outcomes of short dental implants (≤6 mm) supporting single crowns or short fixed partial dentures have been reported differently in different studies and need more clarification. This systematic study evaluated the rate of bone loss (BL), the durability of implants equal to or shorter than 6 mm supporting single crowns or short fixed partial dentures, and prosthetic-related side effects during 5 years of follow-up. Five databases (PubMed, MEDLINE, Scopus, Google Scholar, and Cochrane) were electronically and manually searched for longitudinal studies with a follow-up period of 5 years or more until January 2023. The study question was, "Does the implant equal to or shorter than 6 mm affect BL and survival rate of the implant-supported prosthesis after 5 years of follow-up?". From 752 identified articles, nine studies were selected for further evaluation. After 5 years of follow-up, most studies had more than 90% survival rate and the maximum BL was 0.54 mm. Still, in internal and external connections, these changes were not substantial. For example, screw loosening was the most common problem with implanted prostheses. Implants of 6 mm or shorter are a suitable treatment option in atrophic ridges with good durability and fewer side effects during a follow-up period of more than 5 years.
Collapse
|
50
|
Ashil AM, Sharma A, Jose LK, Grover S, Kochar AS, Varghese ST, Sharma T, Ismail PMS. A CBCT Assessment of Orthodontic Mini- Implant Placement. JOURNAL OF PHARMACY AND BIOALLIED SCIENCES 2024; 16:S927-S929. [PMID: 38595369 PMCID: PMC11000927 DOI: 10.4103/jpbs.jpbs_1102_23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2023] [Revised: 11/01/2023] [Accepted: 11/02/2023] [Indexed: 04/11/2024] Open
Abstract
Objectives This study compares the precision of cone beam computed tomography (CBCT) and two-dimensional radiography for mini-implant implantation. Materials and Method For 30 sites (in 15 patients between the ages of 13 and 26 years), the buccal interradicular region among the 2nd premolar and 1st molar was found to be the best location for mini-implants. Next, two groups of the mini-implant implantation process were created. Mini-implants were positioned at the CBCT data-identified sites in the CBCT group. Mini-implants were inserted in the RVG group by using two-dimensional digital radiography and a specially constructed guide. To assess the precision of the mini-implant implantation, post-placement CBCT images were acquired. The obtained data were statistically analyzed. Result The two groups showed a statistically considerable variation in the mini-implant placement's departure from the optimal height. Due to the smaller interradicular space and decreased convenience in the posterior mandibular area, two out of 15 mini-implants in the RVG group demonstrated root contact in the mandibular jaw. Conclusion The two-dimensional intraoral radiograph of the interradicular area provides sufficient information for mini-implant placement even though CBCT accurately visualizes the interradicular space in three dimensions.
Collapse
|