26
|
Xu Y, Li Y, Shen H, Zhang B, Zhao Q, Cheng Y, Zhao Z, Guo Q, Yang J, Zhou Y. Clinical effectiveness and radial artery remodeling assessment via very-high-frequency ultrasound/ultra biomicroscopy after applying slender 7Fr sheath for transradial approach in left main bifurcation disease. Curr Med Res Opin 2020; 36:1643-1652. [PMID: 32847430 DOI: 10.1080/03007995.2020.1815684] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
OBJECTIVE To explore the clinical effect and radial remodeling of transradial slender 7 Fr sheath for left main bifurcation disease (LM bifurcation). METHODS From January 2018 to September 2019, 236 patients with LM bifurcation undergoing transradial percutaneous coronary intervention (PCI) from two heart centers were divided into slender 7 Fr sheath group (n = 127) and 6 Fr sheath group (n = 109). Quantitative coronary angiography (QCA) and very high-frequency ultrasound/ultra biomicroscopy (VHFUBM) were used to assess the clinical effect and radial remodeling of transradial sheath. RESULTS Slender 7 Fr sheath group had a higher preoperative distal bifurcation angle (67.271 ± 22.886) than 6 Fr group (55.831 ± 20.245) (p < .05). Post-PCI QCA results showed significant differences in minimum lumen diameter at proximal left anterior descending artery (LAD) and left circumflex artery (LCX) between two groups (p < .05). There were no significant differences in target vessel myocardial infarction, target vessel revascularization, death and major adverse cardiocerebrovascular events (MACCE) at 30-day and 1-year follow-up between two groups (p>.05). No significant differences were observed in radial artery diameter (RAD), intimal-medial thickness (IMT) and radial artery injury at 24-h and 90-day follow-up between two groups. CONCLUSION With larger main and side branch diameter, larger angle of bifurcation and higher SYNTAX score, transradial slender 7 Fr sheath obtained similar clinical effects as 6 Fr sheath without increasing the occurrence of adverse events. Similar follow-up RAD, IMT and radial artery injury were observed. Therefore, slender 7 Fr sheath has safety and feasibility in applying to transradial LM-Bifurcation PCI.
Collapse
|
27
|
Ito S, Kinoshita K, Endo A, Kami R, Kotake Y, Nakamura M. Inter- and intra-core laboratory variability in the quantitative coronary angiography analysis for drug-eluting stent treatment and follow up. Ther Adv Cardiovasc Dis 2020; 14:1753944720958982. [PMID: 32993464 PMCID: PMC7534069 DOI: 10.1177/1753944720958982] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
AIM To evaluate inter-core laboratory variability of quantitative coronary angiography (QCA) parameters in comparison with intra-core laboratory variability in a randomized controlled trial evaluating drug-eluting stents. METHODS A total of 50 patients with 62 coronary lesions were analyzed by four analysis experts belonging to an Angiographic Core Laboratory (ACL: 1 expert) and a Cardiovascular Imaging Core Laboratory (CICL: 3 experts). QCA was based on the same standard operating procedure, but selections of projection and cine frames were at the discretion of each analyst. Inter- and intra-core laboratory variabilities were evaluated by accuracy, precision, Bland Altman analysis, and coefficient of variation. RESULTS Pre-MLD (minimal lumen diameter) was significantly smaller in results from ACL than those from all CICL experts. Number of analyzed projections did not affect pre-MLD results. Acute gain was larger in ACL than in CICL2. No significant difference was observed in late loss and loss index between inter-core laboratories. Agreement between core labs in the Bland-Altman analysis for each QCA parameter was as follows (mean difference, 95% limits of agreement): pre-MLD (-0.32, -0.74 to 0.10), stent MLD (0.08, -0.28 to 0.44), acute gain (0.22, -0.44 to 0.88), and late loss (-0.07, -0.69 to 0.55). Agreement between analysts in CICL (mean difference, 95% limits of agreement) was: pre MLD (-0.03, -0.37 to 0.31), stent MLD (0.15, -0.15 to 0.45), acute gain (0.05, -0.45 to 0.55), and late loss (0.04, -0.52 to 0.60). The widest limits of agreement among three analyses were shown in both analyses. Width of limited agreement in the intra-core laboratory analysis tended to be smaller than the inter-core laboratory analysis with these parameters. Coefficient of variation tended to be larger in lesion length (LL), acute gain, late loss, and loss index in inter- and in intra- core laboratory comparisons. CONCLUSION Inter-core laboratory QCA variability in late loss and loss index analysis could be similar to intra-core laboratory variability, but more strict alignment between core laboratories would be necessary for initial procedural data analysis.
Collapse
|
28
|
Sheth T, Pinilla-Echeverri N, Moreno R, Wang J, Wood DA, Storey RF, Mehran R, Bainey KR, Bossard M, Bangalore S, Schwalm JD, Velianou JL, Valettas N, Sibbald M, Rodés-Cabau J, Ducas J, Cohen EA, Bagai A, Rinfret S, Newby DE, Feldman L, Laster SB, Lang IM, Mills JD, Cairns JA, Mehta SR. Nonculprit Lesion Severity and Outcome of Revascularization in Patients With STEMI and Multivessel Coronary Disease. J Am Coll Cardiol 2020; 76:1277-1286. [PMID: 32912441 DOI: 10.1016/j.jacc.2020.07.034] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/01/2020] [Accepted: 07/10/2020] [Indexed: 11/20/2022]
Abstract
BACKGROUND In the COMPLETE (Complete vs Culprit-only Revascularization to Treat Multi-vessel Disease After Early PCI for STEMI) trial, angiography-guided percutaneous coronary intervention (PCI) of nonculprit lesions with the aim of complete revascularization reduced major cardiovascular (CV) events in patients with ST-segment elevation myocardial infarction (MI) and multivessel coronary artery disease. OBJECTIVES The purpose of this study was to determine the effect of nonculprit-lesion stenosis severity measured by quantitative coronary angiography (QCA) on the benefit of complete revascularization. METHODS Among 4,041 patients randomized in the COMPLETE trial, nonculprit lesion stenosis severity was measured using QCA in the angiographic core laboratory in 3,851 patients with 5,355 nonculprit lesions. In pre-specified analyses, the treatment effect in patients with QCA stenosis ≥60% versus <60% on the first coprimary outcome of CV death or new MI and the second co-primary outcome of CV death, new MI, or ischemia-driven revascularization was determined. RESULTS The first coprimary outcome was reduced with complete revascularization in the 2,479 patients with QCA stenosis ≥60% (2.5%/year vs. 4.2%/year; hazard ratio [HR]: 0.61; 95% confidence interval [CI]: 0.47 to 0.79), but not in the 1,372 patients with QCA stenosis <60% (3.0%/year vs. 2.9%/year; HR: 1.04; 95% CI: 0.72 to 1.50; interaction p = 0.02). The second coprimary outcome was reduced in patients with QCA stenosis ≥60% (2.9%/year vs. 6.9%/year; HR: 0.43; 95% CI: 0.34 to 0.54) to a greater extent than patients with QCA stenosis <60% (3.3%/year vs. 5.2%/year; HR: 0.65; 95% CI: 0.47 to 0.89; interaction p = 0.04). CONCLUSIONS Among patients with ST-segment elevation MI and multivessel coronary artery disease, complete revascularization reduced major CV outcomes to a greater extent in patients with stenosis severity of ≥60% compared with <60%, as determined by quantitative coronary angiography.
Collapse
|
29
|
|
30
|
Bourantas CV, Zanchin T, Torii R, Serruys PW, Karagiannis A, Ramasamy A, Safi H, Coskun AU, Koning G, Onuma Y, Zanchin C, Krams R, Mathur A, Baumbach A, Mintz G, Windecker S, Lansky A, Maehara A, Stone PH, Raber L, Stone GW. Shear Stress Estimated by Quantitative Coronary Angiography Predicts Plaques Prone to Progress and Cause Events. JACC Cardiovasc Imaging 2020; 13:2206-2219. [PMID: 32417338 DOI: 10.1016/j.jcmg.2020.02.028] [Citation(s) in RCA: 24] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/19/2019] [Revised: 02/05/2020] [Accepted: 02/14/2020] [Indexed: 10/24/2022]
Abstract
OBJECTIVES This study examined the value of endothelial shear stress (ESS) estimated in 3-dimensional quantitative coronary angiography (3D-QCA) models in detecting plaques that are likely to progress and cause events. BACKGROUND Cumulative evidence has shown that plaque characteristics and ESS derived from intravascular ultrasound (IVUS)-based reconstructions enable prediction of lesions that will cause cardiovascular events. However, the prognostic value of ESS estimated by 3D-QCA in nonflow limiting lesions is yet unclear. METHODS This study analyzed baseline virtual histology (VH)-IVUS and angiographic data from 28 lipid-rich lesions (i.e., fibroatheromas) that caused major adverse cardiovascular events or required revascularization (MACE-R) at 5-year follow-up and 119 lipid-rich plaques from a control group that remained quiescent. The segments studied by VH-IVUS at baseline were reconstructed using 3D-QCA software. In the obtained geometries, blood flow simulation was performed, and the pressure gradient across the lipid-rich plaque and the mean ESS values in 3-mm segments were estimated. The additive value of these hemodynamic indexes in predicting MACE-R beyond plaque characteristics was examined. RESULTS MACE-R lesions were longer, had smaller minimum lumen area, increased plaque burden (PB), were exposed to higher ESS, and exhibited a higher pressure gradient. In multivariable analysis, PB (hazard ratio: 1.08; p = 0.004) and the maximum 3-mm ESS value (hazard ratio: 1.11; p = 0.001) were independent predictors of MACE-R. Lesions exposed to high ESS (>4.95 Pa) with a high-risk anatomy (minimal lumen area <4 mm2 and PB >70%) had a higher MACE-R rate (53.8%) than those with a low-risk anatomy exposed to high ESS (31.6%) or those exposed to low ESS who had high- (20.0%) or low-risk anatomy (7.1%; p < 0.001). CONCLUSIONS In the present study, 3D-QCA-derived local hemodynamic variables provided useful prognostic information, and, in combination with lesion anatomy, enabled more accurate identification of MACE-R lesions.
Collapse
|
31
|
Ito S, Kinoshita K, Endo A, Nakamura M. Impact of Cine Frame Selection on Quantitative Coronary Angiography Results. CLINICAL MEDICINE INSIGHTS-CARDIOLOGY 2019; 13:1179546819838232. [PMID: 30967747 PMCID: PMC6444776 DOI: 10.1177/1179546819838232] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/13/2018] [Accepted: 02/19/2019] [Indexed: 11/15/2022]
Abstract
We evaluated intra- and interobserver variability of quantitative coronary
angiography (QCA) due to cine frame selection for 9 coronary stenoses. The
projection was selected in advance. Cine frames were selected by 2 blinded
experts (blind frame QCA) followed by assignment by supervisor (pre-selected
frame QCA). Each expert analyzed 18 frames twice with a 3-month interval. A
total of 72 measurements by 2 experts were used for intra- and interobserver
variability analysis in calibration factor (CF), minimal lumen diameter (MLD),
percent diameter stenosis (%DS), interpolated reference diameter (Int R), and
lesion length (LL). Accuracy, precision, and coefficient of variation (CV) were
calculated based on 2 measurements. For interobserver variability, intraclass
correlation coefficient (ICC) was evaluated. Regarding intraobserver
variability, precision (CV) was 0.0026 (1.45), 0.220 (25.1), 0.282 (11.0), 7.626
(11.8), and 4.042 (28.7) for blind frame QCA and 0.0044 (2.46), 0.094 (11.2),
0.225 (8.6), 3.924 (5.9), and 1.941 (12.1) for pre-selected frame QCA and
regarding interobserver variability, precision (CV) was 0.0037 (2.09), 0.271
(31.8), 0.307 (11.9), 10.10 (15.4), and 5.121 (39.5) for blind frame QCA and
0.0050 (2.82), 0.098 (11.4), 0.246 (9.5), 5.253 (8.0), and 2.857 (19.0) for
pre-selected frame QCA in CF, MLD, Int R, %DS, and LL, respectively. Intraclass
correlation coefficient of Int R was almost perfect in blind and pre-selected
frame QCA. Intraclass correlation coefficient of MLD, %DS, and LL were
substantial/lower by blind frame QCA and improved to almost perfect by
pre-selected frame QCA. Blind cine film selection might affect intra- and
interobserver variability, especially in MLD and LL. In the multiple linear
regression analysis, blind frame QCA was selected as an explanatory factor of
QCA variability in MLD, %DS, and LL. The error range due to frame selection must
be taken into consideration in clinical use.
Collapse
|
32
|
Bezerra CG, Hideo-Kajita A, Bulant CA, Maso-Talou GD, Mariani J, Pinton FA, Falcão BAA, Esteves-Filho A, Franken M, Feijóo RA, Kalil-Filho R, Garcia-Garcia HM, Blanco PJ, Lemos PA. Coronary fractional flow reserve derived from intravascular ultrasound imaging: Validation of a new computational method of fusion between anatomy and physiology. Catheter Cardiovasc Interv 2018; 93:266-274. [PMID: 30277641 DOI: 10.1002/ccd.27822] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/05/2018] [Accepted: 07/15/2018] [Indexed: 12/26/2022]
Abstract
OBJECTIVES To evaluate the diagnostic performance of a novel computational algorithm based on three-dimensional intravascular ultrasound (IVUS) imaging in estimating fractional flow reserve (IVUSFR ), compared to gold-standard invasive measurements (FFRINVAS ). BACKGROUND IVUS provides accurate anatomical evaluation of the lumen and vessel wall and has been validated as a useful tool to guide percutaneous coronary intervention. However, IVUS poorly represents the functional status (i.e., flow-related information) of the imaged vessel. METHODS Patients with known or suspected stable coronary disease scheduled for elective cardiac catheterization underwent FFRINVAS measurement and IVUS imaging in the same procedure to evaluate intermediate lesions. A processing methodology was applied on IVUS to generate a computational mesh condensing the geometric characteristics of the vessel. Computation of IVUSFR was obtained from patient-level morphological definition of arterial districts and from territory-specific boundary conditions. FFRINVAS measurements were dichotomized at the 0.80 threshold to define hemodynamically significant lesions. RESULTS A total of 24 patients with 34 vessels were analyzed. IVUSFR significantly correlated (r = 0.79; P < 0.001) and showed good agreement with FFRINVAS , with a mean difference of -0.008 ± 0.067 (P = 0.47). IVUSFR presented an overall accuracy, sensitivity, specificity, positive predictive value, and negative predictive value of 91%, 89%, 92%, 80%, and 96%, respectively, to detect significant stenosis. CONCLUSION The computational processing of IVUSFR is a new method that allows the evaluation of the functional significance of coronary stenosis in an accurate way, enriching the anatomical information of grayscale IVUS.
Collapse
|
33
|
Westra J, Andersen BK, Campo G, Matsuo H, Koltowski L, Eftekhari A, Liu T, Di Serafino L, Di Girolamo D, Escaned J, Nef H, Naber C, Barbierato M, Tu S, Neghabat O, Madsen M, Tebaldi M, Tanigaki T, Kochman J, Somi S, Esposito G, Mercone G, Mejia-Renteria H, Ronco F, Bøtker HE, Wijns W, Christiansen EH, Holm NR. Diagnostic Performance of In-Procedure Angiography-Derived Quantitative Flow Reserve Compared to Pressure-Derived Fractional Flow Reserve: The FAVOR II Europe-Japan Study. J Am Heart Assoc 2018; 7:JAHA.118.009603. [PMID: 29980523 PMCID: PMC6064860 DOI: 10.1161/jaha.118.009603] [Citation(s) in RCA: 225] [Impact Index Per Article: 37.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Abstract
Background Quantitative flow ratio (QFR) is a novel modality for physiological lesion assessment based on 3‐dimensional vessel reconstructions and contrast flow velocity estimates. We evaluated the value of online QFR during routine invasive coronary angiography for procedural feasibility, diagnostic performance, and agreement with pressure‐wire–derived fractional flow reserve (FFR) as a gold standard in an international multicenter study. Methods and Results FAVOR II E‐J (Functional Assessment by Various Flow Reconstructions II Europe‐Japan) was a prospective, observational, investigator‐initiated study. Patients with stable angina pectoris were enrolled in 11 international centers. FFR and online QFR computation were performed in all eligible lesions. An independent core lab performed 2‐dimensional quantitative coronary angiography (2D‐QCA) analysis of all lesions assessed with QFR and FFR. The primary comparison was sensitivity and specificity of QFR compared with 2D‐QCA using FFR as a reference standard. A total of 329 patients were enrolled. Paired assessment of FFR, QFR, and 2D‐QCA was available for 317 lesions. Mean FFR, QFR, and percent diameter stenosis were 0.83±0.09, 0.82±10, and 45±10%, respectively. FFR was ≤0.80 in 104 (33%) lesions. Sensitivity and specificity by QFR was significantly higher than by 2D‐QCA (sensitivity, 86.5% (78.4–92.4) versus 44.2% (34.5–54.3); P<0.001; specificity, 86.9% (81.6–91.1) versus 76.5% (70.3–82.0); P=0.002). Area under the receiver curve was significantly higher for QFR compared with 2D‐QCA (area under the receiver curve, 0.92 [0.89–0.96] versus 0.64 [0.57–0.70]; P<0.001). Median time to QFR was significantly lower than median time to FFR (time to QFR, 5.0 minutes [interquartile range, –6.1] versus time to FFR, 7.0 minutes [interquartile range, 5.0–10.0]; P<0.001). Conclusions Online computation of QFR in the catheterization laboratory is clinically feasible and is superior to angiographic assessment for evaluation of intermediary coronary artery stenosis using FFR as a reference standard. Clinical Trial Registration URL: https://www.clinicaltrials.gov. Unique identifier: NCT02959814.
Collapse
|
34
|
Xu B, Tu S, Qiao S, Qu X, Chen Y, Yang J, Guo L, Sun Z, Li Z, Tian F, Fang W, Chen J, Li W, Guan C, Holm NR, Wijns W, Hu S. Diagnostic Accuracy of Angiography-Based Quantitative Flow Ratio Measurements for Online Assessment of Coronary Stenosis. J Am Coll Cardiol 2017; 70:3077-3087. [PMID: 29101020 DOI: 10.1016/j.jacc.2017.10.035] [Citation(s) in RCA: 321] [Impact Index Per Article: 45.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/15/2017] [Revised: 10/13/2017] [Accepted: 10/16/2017] [Indexed: 11/27/2022]
Abstract
BACKGROUND Quantitative flow ratio (QFR) is a novel angiography-based method for deriving fractional flow reserve (FFR) without pressure wire or induction of hyperemia. The accuracy of QFR when assessed online in the catheterization laboratory has not been adequately examined to date. OBJECTIVES The goal of this study was to assess the diagnostic performance of QFR for the diagnosis of hemodynamically significant coronary stenosis defined by FFR ≤0.80. METHODS This prospective, multicenter trial enrolled patients who had at least 1 lesion with a diameter stenosis of 30% to 90% and a reference diameter ≥2 mm according to visual estimation. QFR, quantitative coronary angiography (QCA), and wire-based FFR were assessed online in blinded fashion during coronary angiography and re-analyzed offline at an independent core laboratory. The primary endpoint was that QFR would improve the diagnostic accuracy of coronary angiography such that the lower boundary of the 2-sided 95% confidence interval (CI) of this estimate exceeded 75%. RESULTS Between June and July 2017, a total of 308 patients were consecutively enrolled at 5 centers. Online QFR and FFR results were both obtained in 328 of 332 interrogated vessels. Patient- and vessel-level diagnostic accuracy of QFR was 92.4% (95% CI: 88.9% to 95.1%) and 92.7% (95% CI: 89.3% to 95.3%), respectively, both of which were significantly higher than the pre-specified target value (p < 0.001). Sensitivity and specificity in identifying hemodynamically significant stenosis were significantly higher for QFR than for QCA (sensitivity: 94.6% vs. 62.5%; difference: 32.0% [p < 0.001]; specificity: 91.7% vs. 58.1%; difference: 36.1% [p < 0.001]). Positive predictive value, negative predictive value, positive likelihood ratio, and negative likelihood ratio for QFR were 85.5%, 97.1%, 11.4, and 0.06. Offline analysis also revealed that vessel-level QFR had a high diagnostic accuracy of 93.3% (95% CI: 90.0% to 95.7%). CONCLUSIONS The study met its prespecified primary performance goal for the level of diagnostic accuracy of QFR in identifying hemodynamically significant coronary stenosis. (The FAVOR [Functional Diagnostic Accuracy of Quantitative Flow Ratio in Online Assessment of Coronary Stenosis] II China study]; NCT03191708).
Collapse
|
35
|
Tu S, Westra J, Yang J, von Birgelen C, Ferrara A, Pellicano M, Nef H, Tebaldi M, Murasato Y, Lansky A, Barbato E, van der Heijden LC, Reiber JHC, Holm NR, Wijns W. Diagnostic Accuracy of Fast Computational Approaches to Derive Fractional Flow Reserve From Diagnostic Coronary Angiography: The International Multicenter FAVOR Pilot Study. JACC Cardiovasc Interv 2017; 9:2024-2035. [PMID: 27712739 DOI: 10.1016/j.jcin.2016.07.013] [Citation(s) in RCA: 362] [Impact Index Per Article: 51.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/22/2016] [Revised: 06/25/2016] [Accepted: 06/30/2016] [Indexed: 12/24/2022]
Abstract
OBJECTIVES The aim of this prospective multicenter study was to identify the optimal approach for simple and fast fractional flow reserve (FFR) computation from radiographic coronary angiography, called quantitative flow ratio (QFR). BACKGROUND A novel, rapid computation of QFR pullbacks from 3-dimensional quantitative coronary angiography was developed recently. METHODS QFR was derived from 3 flow models with: 1) fixed empiric hyperemic flow velocity (fixed-flow QFR [fQFR]); 2) modeled hyperemic flow velocity derived from angiography without drug-induced hyperemia (contrast-flow QFR [cQFR]); and 3) measured hyperemic flow velocity derived from angiography during adenosine-induced hyperemia (adenosine-flow QFR [aQFR]). Pressure wire-derived FFR, measured during maximal hyperemia, served as the reference. Separate independent core laboratories analyzed angiographic images and pressure tracings from 8 centers in 7 countries. RESULTS The QFR and FFR from 84 vessels in 73 patients with intermediate coronary lesions were compared. Mean angiographic percent diameter stenosis (DS%) was 46.1 ± 8.9%; 27 vessels (32%) had FFR ≤ 0.80. Good agreement with FFR was observed for fQFR, cQFR, and aQFR, with mean differences of 0.003 ± 0.068 (p = 0.66), 0.001 ± 0.059 (p = 0.90), and -0.001 ± 0.065 (p = 0.90), respectively. The overall diagnostic accuracy for identifying an FFR of ≤0.80 was 80% (95% confidence interval [CI]: 71% to 89%), 86% (95% CI: 78% to 93%), and 87% (95% CI: 80% to 94%). The area under the receiver-operating characteristic curve was higher for cQFR than fQFR (difference: 0.04; 95% CI: 0.01 to 0.08; p < 0.01), but did not differ significantly between cQFR and aQFR (difference: 0.01; 95% CI: -0.04 to 0.06; p = 0.65). Compared with DS%, both cQFR and aQFR increased the area under the receiver-operating characteristic curve by 0.20 (p < 0.01) and 0.19 (p < 0.01). The positive likelihood ratio was 4.8, 8.4, and 8.9 for fQFR, cQFR, and aQFR, with negative likelihood ratio of 0.4, 0.3, and 0.2, respectively. CONCLUSIONS The QFR computation improved the diagnostic accuracy of 3-dimensional quantitative coronary angiography-based identification of stenosis significance. The favorable results of cQFR that does not require pharmacologic hyperemia induction bears the potential of a wider adoption of FFR-based lesion assessment through a reduction in procedure time, risk, and costs.
Collapse
|
36
|
Noninvasive CT-Derived FFR Based on Structural and Fluid Analysis: A Comparison With Invasive FFR for Detection of Functionally Significant Stenosis. JACC Cardiovasc Imaging 2016; 10:663-673. [PMID: 27771399 DOI: 10.1016/j.jcmg.2016.07.005] [Citation(s) in RCA: 137] [Impact Index Per Article: 17.1] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/21/2016] [Revised: 07/11/2016] [Accepted: 07/14/2016] [Indexed: 01/16/2023]
Abstract
OBJECTIVES This study describes the feasibility and accuracy of a novel computed tomography (CT) fractional flow reserve (FFR) technique based on alternative boundary conditions. BACKGROUND Techniques used to compute FFR based on images acquired from coronary computed tomography angiography (CTA) are described. Boundary conditions were typically determined by allometric scaling laws and assumptions regarding microvascular resistance. Alternatively, boundary conditions can be derived from the structural deformation of coronary lumen and aorta, although its accuracy remains unknown. METHODS Forty-two patients (78 vessels) in a single institution prospectively underwent 320-detector coronary CTA and FFR. Deformation of coronary cross-sectional lumen and aorta, computed from coronary CTA images acquired over diastole, was used to determine the boundary conditions based on hierarchical Bayes modeling. CT-FFR was derived using a reduced order model performed using a standard desktop computer and dedicated software. First, 12 patients (20 vessels) formed the derivation cohort to determine optimal CT-FFR threshold with which to detect functional stenosis, defined as FFR of ≤0.8, which was validated in the subsequent 30 patients (58 vessels). RESULTS Derivation cohort results demonstrated optimal threshold for CT-FFR was 0.8 with 67% sensitivity and 91% specificity. In the validation cohort, CT-FFR was successfully computed in 56 of 58 vessels (97%). Compared with coronary CTA, CT-FFR at ≤0.8 demonstrated a higher specificity (87% vs. 74%, respectively) and positive predictive value (74% vs. 60%, respectively), with comparable sensitivity (78% vs. 79%, respectively), negative predictive value (89% vs. 88%, respectively), and accuracy (area under the curve: 0.88 vs. 0.77, respectively; p = 0.22). Based on Bland-Altman analysis, mean intraobserver and interobserver variability values for CT-FFR were, respectively, -0.02 ± 0.05 (95% limits of agreement: -0.12 to 0.08) and 0.03 ± 0.06 (95% limits: 0.07 to 0.19). Mean time per patient for CT-FFR analysis was 27.07 ± 7.54 min. CONCLUSIONS CT-FFR based on alternative boundary conditions and reduced-order fluid model is feasible, highly reproducible, and may be accurate in detecting FFR ≤ 0.8. It requires a short processing time and can be completed at point-of-care. Further validation is required in large prospective multicenter settings.
Collapse
|
37
|
Zhang YJ, Zhu H, Shi SY, Muramatsu T, Pan DR, Ye F, Zhang JJ, Tian NL, Bourantas CV, Chen SL. Comparison between two-dimensional and three-dimensional quantitative coronary angiography for the prediction of functional severity in true bifurcation lesions: Insights from the randomized DK-CRUSH II, III, and IV trials. Catheter Cardiovasc Interv 2016; 87 Suppl 1:589-98. [PMID: 26876688 DOI: 10.1002/ccd.26405] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/09/2015] [Accepted: 12/21/2015] [Indexed: 11/11/2022]
Abstract
OBJECTIVE This study investigated the diagnostic accuracy of three-dimensional quantitative coronary angiography (3D-QCA) compared with conventional 2D-QCA for predicting functional severity assessed by fractional flow reserve (FFR) for true bifurcation lesions. METHODS Based on pooled data from the randomized DK-CRUSH II, III, and IV trials, we evaluated the patients with true bifurcation lesions who underwent coronary angiography together with functional evaluations using FFR in both the main vessel and the side branch. Off-line 2D- and 3D-QCA analyses were conducted using dedicated bifurcation QCA analysis software. Measurements of minimum lumen diameter (MLD), percentage diameter stenosis (% DS), and minimum lumen area (MLA) were compared between 2D- and 3D-QCA, and we evaluated their predictive values of functionally significant FFR. RESULTS Ninety patients were eligible for enrollment in the present study. In the main vessel, MLA measured by 3D-QCA was the most accurate predictor of FFR <0.75 (C statistic 0.85, P < 0.001), while MLD measured by 2D-QCA was a similarly accurate predictor (C statistic 0.85, P < 0.001). In the side branch, the best metrics for predicting FFR <0.75 were % DS measured by 2D-QCA with a C statistic value of 0.91 (P < 0.001) and MLA measured by 3D-QCA with a C statistic value of 0.81 (P < 0.001). However, both 2D- and 3D-QCA metrics exhibited low accuracies for predicting FFR <0.75 in intermediate bifurcation lesions. CONCLUSIONS 3D-QCA analysis for true bifurcation lesions did not improve the predictive accuracy of functionally significant FFR compared with 2D-QCA analysis. In lesions with intermediate stenosis, the diagnostic performance of both 2D- and 3D-QCA-derived measurements in differentiating functional severity is limited.
Collapse
|
38
|
Hoppmann P, Kufner S, Cassese S, Wiebe J, Schneider S, Pinieck S, Scheler L, Bernlochner I, Joner M, Schunkert H, Laugwitz KL, Kastrati A, Byrne RA. Angiographic and clinical outcomes of patients treated with everolimus-eluting bioresorbable stents in routine clinical practice: Results of the ISAR-ABSORB registry. Catheter Cardiovasc Interv 2015; 87:822-9. [PMID: 26708019 DOI: 10.1002/ccd.26346] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/25/2015] [Accepted: 11/08/2015] [Indexed: 11/10/2022]
Abstract
OBJECTIVES We aimed to analyze angiographic and clinical results of patients undergoing BRS implantation in a real-world setting. BACKGROUND Angiographic and clinical outcome data from patients undergoing implantation of drug-eluting bioresorbable stents (BRS) in routine clinical practice is scant. METHODS Consecutive patients undergoing implantation of everolimus-eluting BRS at two high-volume centers in Munich, Germany were enrolled. Data were collected prospectively. All patients were scheduled for angiographic surveillance 6-8 months after stent implantation. Quantitative coronary angiographic analysis was performed in a core laboratory. Clinical follow-up was performed to 12 months and events were adjudicated by independent assessors. RESULTS A total of 419 patients were studied. Mean age was 66.6 ± 10.9 years, 31.5% had diabetes mellitus, 76.1% had multivessel disease, and 39.0% presented with acute coronary syndrome; 49.0% of lesions were AHA/ACC type B2/C, 13.1% had treatment of bifurcation lesions. Mean reference vessel diameter was 2.89 ± 0.46 mm. At angiographic follow-up in-stent late loss was 0.26 ± 0.51 mm, in-segment diameter stenosis was 27.5 ± 16.1, and binary angiographic restenosis was 7.5%. At 12 months, the rate of death, myocardial infarction, or target lesion revascularization was 13.1%. Definite stent thrombosis occurred in 2.6%. CONCLUSIONS The use of everolimus-eluting BRS in routine clinical practice is associated with high antirestenotic efficacy in patients undergoing angiographic surveillance. Overall clinical outcomes at 12 months are satisfactory though stent thrombosis rates are not insignificant. Further study with longer term follow-up and larger numbers of treated patients is required before we can be sure of the role of these devices in clinical practice.
Collapse
|
39
|
Tu S, Barbato E, Köszegi Z, Yang J, Sun Z, Holm NR, Tar B, Li Y, Rusinaru D, Wijns W, Reiber JHC. Fractional flow reserve calculation from 3-dimensional quantitative coronary angiography and TIMI frame count: a fast computer model to quantify the functional significance of moderately obstructed coronary arteries. JACC Cardiovasc Interv 2015; 7:768-77. [PMID: 25060020 DOI: 10.1016/j.jcin.2014.03.004] [Citation(s) in RCA: 247] [Impact Index Per Article: 27.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/28/2014] [Revised: 03/21/2014] [Accepted: 03/27/2014] [Indexed: 11/19/2022]
Abstract
OBJECTIVES This study sought to present a novel computer model for fast computation of myocardial fractional flow reserve (FFR) and to evaluate it in patients with intermediate coronary stenoses. BACKGROUND FFR is an indispensable tool to identify individual coronary stenoses causing ischemia. Calculation of FFR from x-ray angiographic data may increase the utility of FFR assessment. METHODS Consecutive patients with intermediate coronary stenoses undergoing pressure wire-based FFR measurements were analyzed by a core laboratory. Three-dimensional quantitative coronary angiography (QCA) was performed and the mean volumetric flow rate at hyperemia was calculated using TIMI (Thrombolysis In Myocardial Infarction) frame count combined with 3-dimensional QCA. Computational fluid dynamics was applied subsequently with a novel strategy for the computation of FFR. Diagnostic performance of the computed FFR (FFRQCA) was assessed using wire-based FFR as reference standard. RESULTS Computation of FFRQCA was performed on 77 vessels in 68 patients. Average diameter stenosis was 46.6 ± 7.3%. FFRQCA correlated well with FFR (r = 0.81, p < 0.001), with a mean difference of 0.00 ± 0.06 (p = 0.541). Applying the FFR cutoff value of ≤0.8 to FFRQCA resulted in 18 true positives, 50 true negatives, 4 false positives, and 5 false negatives. The area under the receiver-operating characteristic curve was 0.93 for FFRQCA, 0.73 for minimum lumen area, and 0.65 for percent diameter stenosis. CONCLUSIONS Computation of FFRQCA is a novel method that allows the assessment of the functional significance of intermediate stenosis. It may emerge as a safe, efficient, and cost-reducing tool for evaluation of coronary stenosis severity during diagnostic angiography.
Collapse
|
40
|
Wang G, Sun Z, Jin Q, Xu K, Li Y, Wang X, Ma Y, Liu H, Zhao X, Wang B, Deng J, Guan S, Ge M, Wang X, Xu B, Han Y. First-in-man study evaluating the safety and efficacy of a second generation biodegradable polymer sirolimus-eluting stent in the treatment of patients with de novo coronary lesions: clinical, Angiographic, and OCT outcomes of CREDIT-1. Catheter Cardiovasc Interv 2015; 85 Suppl 1:744-51. [PMID: 25630447 DOI: 10.1002/ccd.25862] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/31/2014] [Accepted: 01/07/2015] [Indexed: 11/08/2022]
Abstract
OBJECTIVE To evaluate the preliminary safety and efficacy of the EXCEL II stent system. BACKGROUND Although the first biodegradable polymer drug-eluting stent (BP-DES), EXCEL, was launched nearly a decade ago, in-stent restenosis and stent thrombosis remain pertinent clinical problems in practice. A new cobalt-chromium BP-DES EXCEL II has been developed with the aim of improving stent safety and efficacy. METHODS Forty-five patients with single de novo native coronary lesions were enrolled and randomized to two groups in a 2:1 ratio, the 4-month follow-up group (n = 30) and the 12-month follow-up group (n = 15). All patients underwent percutaneous coronary intervention (PCI) with the EXCEL II stent system. Quantitative coronary angiography (QCA) and optical coherence tomography (OCT) were used to assess coronary vasculature at the designated 4- or 12-month follow-up. The primary outcome was major adverse cardiac events (MACE) at 30 days post-PCI. RESULTS No MACE, thrombotic events, or target lesion failure was found in the 45 patients during the 12-month follow-up. There was no significant difference (P > 0.05) between the two groups in terms of in-stent and in-segment late lumen loss (LLL). No in-stent and in-segment restenosis was found in either group. At follow-up, the ratio of >10% uncovered struts per lesion was 26.67% in the 4-month group and 0% in the 12-month group (P < 0.05). Neointimal coverage in the 12-month group was significantly better than in the 4-month group (98.58% vs. 93.51%, P < 0.01). CONCLUSIONS This first-in-man study demonstrates promising feasibility, safety, and efficacy of EXCEL II stents. These stents were found to have rapid endothelialization and low LLL rates at 4 and 12 months after implantation.
Collapse
|
41
|
Campbell PT, Mahmud E, Marshall JJ. Interoperator and intraoperator (in)accuracy of stent selection based on visual estimation. Catheter Cardiovasc Interv 2015; 86:1177-83. [PMID: 25510826 DOI: 10.1002/ccd.25780] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/17/2014] [Accepted: 11/29/2014] [Indexed: 11/06/2022]
Abstract
OBJECTIVES The objectives of this study were to evaluate the ability of interventional cardiologists to accurately measure lesion length and select appropriate stents. BACKGROUND Inaccurate measurement of lesion length during percutaneous coronary intervention (PCI) increases the risk of restenosis. METHODS Interventional cardiologists (n = 40) evaluated 25 matched orthogonal angiographic images that were prescored using quantitative coronary angiography (QCA) by a core laboratory. Visual estimates of lesion length and stent length selection were compared to the maximum QCA value. A 2-4 mm stent overlap of both the proximal and distal lesion edges was considered to be optimal. Based on optimal stent overlap, accurate lesion lengths were those measured from -1 to +4 mm from the QCA. Likewise, appropriate stent lengths were those that measured between +4 mm to +8 mm from the QCA value. Five images were repeated to assess intrarater variability. RESULTS Lesion length measurements were short and long for 51.1% (95% CI 47.6-54.6%) and 19.0% (95% CI 16.3-21.9%) of the images, respectively. Stent length selections that were short and long were recorded for 55.0% (95% CI 51.5-58.5%) and 22.8% (95% CI 19.9-25.8%) of the images, respectively. Intrarater variability evaluation indicated that 38.5% (95% CI 31.7-45.6%) of lesion length measurements and 37.5% (95% CI 30.8-44.6%) of stent length selections were >3 mm different between the first and second evaluation of repeated images. CONCLUSIONS Visual estimation of coronary lesion length has a high degree of variability, which may lead to inappropriate stent selection. Improving the accuracy of lesion length measurement may improve patient outcomes.
Collapse
|
42
|
Mordini FE, Haddad T, Hsu LY, Kellman P, Lowrey TB, Aletras AH, Bandettini WP, Arai AE. Diagnostic accuracy of stress perfusion CMR in comparison with quantitative coronary angiography: fully quantitative, semiquantitative, and qualitative assessment. JACC Cardiovasc Imaging 2015; 7:14-22. [PMID: 24433707 DOI: 10.1016/j.jcmg.2013.08.014] [Citation(s) in RCA: 80] [Impact Index Per Article: 8.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/11/2013] [Revised: 08/19/2013] [Accepted: 08/22/2013] [Indexed: 12/13/2022]
Abstract
OBJECTIVES This study's primary objective was to determine the sensitivity, specificity, and accuracy of fully quantitative stress perfusion cardiac magnetic resonance (CMR) versus a reference standard of quantitative coronary angiography. We hypothesized that fully quantitative analysis of stress perfusion CMR would have high diagnostic accuracy for identifying significant coronary artery stenosis and exceed the accuracy of semiquantitative measures of perfusion and qualitative interpretation. BACKGROUND Relatively few studies apply fully quantitative CMR perfusion measures to patients with coronary disease and comparisons to semiquantitative and qualitative methods are limited. METHODS Dual bolus dipyridamole stress perfusion CMR exams were performed in 67 patients with clinical indications for assessment of myocardial ischemia. Stress perfusion images alone were analyzed with a fully quantitative perfusion (QP) method and 3 semiquantitative methods including contrast enhancement ratio, upslope index, and upslope integral. Comprehensive exams (cine imaging, stress/rest perfusion, late gadolinium enhancement) were analyzed qualitatively with 2 methods including the Duke algorithm and standard clinical interpretation. A 70% or greater stenosis by quantitative coronary angiography was considered abnormal. RESULTS The optimum diagnostic threshold for QP determined by receiver-operating characteristic curve occurred when endocardial flow decreased to <50% of mean epicardial flow, which yielded a sensitivity of 87% and specificity of 93%. The area under the curve for QP was 92%, which was superior to semiquantitative methods: contrast enhancement ratio: 78%; upslope index: 82%; and upslope integral: 75% (p = 0.011, p = 0.019, p = 0.004 vs. QP, respectively). Area under the curve for QP was also superior to qualitative methods: Duke algorithm: 70%; and clinical interpretation: 78% (p < 0.001 and p < 0.001 vs. QP, respectively). CONCLUSIONS Fully quantitative stress perfusion CMR has high diagnostic accuracy for detecting obstructive coronary artery disease. QP outperforms semiquantitative measures of perfusion and qualitative methods that incorporate a combination of cine, perfusion, and late gadolinium enhancement imaging. These findings suggest a potential clinical role for quantitative stress perfusion CMR.
Collapse
|
43
|
Tomkowiak MT, Raval AN, Van Lysel MS, Funk T, Speidel MA. Calibration-free coronary artery measurements for interventional device sizing using inverse geometry x-ray fluoroscopy: in vivo validation. J Med Imaging (Bellingham) 2014; 1. [PMID: 25544948 DOI: 10.1117/1.jmi.1.3.033504] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
Proper sizing of interventional devices to match coronary vessel dimensions improves procedural efficiency and therapeutic outcomes. We have developed a method that uses an inverse geometry x-ray fluoroscopy system [scanning beam digital x-ray (SBDX)] to automatically determine vessel dimensions from angiograms without the need for magnification calibration or optimal views. For each frame period (1/15th of a second), SBDX acquires a sequence of narrow beam projections and performs digital tomosynthesis at multiple plane positions. A three-dimensional model of the vessel is reconstructed by localizing the depth of the vessel edges from the tomosynthesis images, and the model is used to calculate the length and diameter in units of millimeters. The in vivo algorithm performance was evaluated in a healthy porcine model by comparing end-diastolic length and diameter measurements from SBDX to coronary computed tomography angiography (CCTA) and intravascular ultrasound (IVUS), respectively. The length error was -0.49 ± 1.76 mm(SBDX- CCTA, mean ± 1 SD). The diameter error was 0.07 ± 0.27 mm (SBDX - minimum IVUS diameter, mean ± 1 SD). The in vivo agreement between SBDX-based vessel sizing and gold standard techniques supports the feasibility of calibration-free coronary vessel sizing using inverse geometry x-ray fluoroscopy.
Collapse
|
44
|
Onuma Y, Dudek D, Thuesen L, Webster M, Nieman K, Garcia-Garcia HM, Ormiston JA, Serruys PW. Five-year clinical and functional multislice computed tomography angiographic results after coronary implantation of the fully resorbable polymeric everolimus-eluting scaffold in patients with de novo coronary artery disease: the ABSORB cohort A trial. JACC Cardiovasc Interv 2014; 6:999-1009. [PMID: 24156961 DOI: 10.1016/j.jcin.2013.05.017] [Citation(s) in RCA: 135] [Impact Index Per Article: 13.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/16/2013] [Revised: 05/03/2013] [Accepted: 05/24/2013] [Indexed: 12/18/2022]
Abstract
OBJECTIVES This study sought to demonstrate the 5-year clinical and functional multislice computed tomography angiographic results after implantation of the fully resorbable everolimus-eluting scaffold (Absorb BVS, Abbott Vascular, Santa Clara, California). BACKGROUND Multimodality imaging of the first-in-humans trial using a ABSORB BVS scaffold demonstrated at 2 years the bioresorption of the device while preventing restenosis. However, the long-term safety and efficacy of this therapy remain to be documented. METHODS In the ABSORB cohort A trial (ABSORB Clinical Investigation, Cohort A [ABSORB A] Everolimus-Eluting Coronary Stent System Clinical Investigation), 30 patients with a single de novo coronary artery lesion were treated with the fully resorbable everolimus-eluting Absorb scaffold at 4 centers. As an optional investigation in 3 of the 4 centers, the patients underwent multislice computed tomography (MSCT) angiography at 18 months and 5 years. Acquired MSCT data were analyzed at an independent core laboratory (Cardialysis, Rotterdam, the Netherlands) for quantitative analysis of lumen dimensions and was further processed for calculation of fractional flow reserve (FFR) at another independent core laboratory (Heart Flow, Redwood City, California). RESULTS Five-year clinical follow-up is available for 29 patients. One patient withdrew consent after 6 months, but the vital status of this patient remains available. At 46 days, 1 patient experienced a single episode of chest pain and underwent a target lesion revascularization with a slight troponin increase after the procedure. At 5 years, the ischemia-driven major adverse cardiac event rate of 3.4% remained unchanged. Clopidogrel was discontinued in all but 1 patient. Scaffold thrombosis was not observed in any patient. Two noncardiac deaths were reported, 1 caused by duodenal perforation and the other from Hodgkin's disease. At 5 years, 18 patients underwent MSCT angiography. All scaffolds were patent, with a median minimal lumen area of 3.25 mm(2) (interquartile range: 2.20 to 4.30). Noninvasive FFR analysis was feasible in 13 of 18 scans, which yielded a median distal FFR of 0.86 (interquartile range: 0.82 to 0.94). CONCLUSIONS The low event rate at 5 years suggests sustained safety after the implantation of a fully bioresorbable Absorb everolimus-eluting scaffold. Noninvasive assessment of the coronary artery with an option of functional assessment could be an alternative to invasive imaging after treatment of coronary narrowing with such a polymeric bioresorbable scaffold. (ABSORB Clinical Investigation, Cohort A [ABSORB A] Everolimus-Eluting Coronary Stent System Clinical Investigation [ABSORB]; NCT00300131).
Collapse
|
45
|
Brunetti ND, Delli Carri F, Ruggiero MA, Cuculo A, Ruggiero A, Ziccardi L, De Gennaro L, Di Biase M. Comparative cath-lab assessment of coronary stenosis by radiology technician, junior and senior interventional cardiologist in patients treated with coronary angioplasty. Interv Med Appl Sci 2014; 6:26-30. [PMID: 24672672 DOI: 10.1556/imas.6.2014.1.4] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2013] [Revised: 12/29/2013] [Accepted: 01/02/2014] [Indexed: 11/19/2022] Open
Abstract
BACKGROUND Exact quantification of plaque extension during coronary angioplasty (PCI) usually falls on interventional cardiologist (IC). Quantitative coronary stenosis assessment (QCA) may be possibly committed to the radiology technician (RT), who usually supports cath-lab nurse and IC during PCI. We therefore sought to investigate the reliability of QCA performed by RT in comparison with IC. METHODS Forty-four consecutive patients with acute coronary syndrome underwent PCI; target coronary vessel size beneath target coronary lesion (S) and target coronary lesion length (L) were assessed by the RT, junior IC (JIC), and senior IC (SIC) and then compared. SIC evaluation, which determined the final stent selection for coronary stenting, was considered as a reference benchmark. RESULTS RT performance with QCA support in assessing target vessel size and target lesion length was not significantly different from SIC (r = 0.46, p < 0.01; r = 0.64, p < 0.001, respectively) as well as JIC (r = 0.79, r = 0.75, p < 0.001, respectively). JIC performance was significantly better than RT in assessing target vessel size (p < 0.05), while not significant when assessing target lesion length. CONCLUSIONS RT may reliably assess target lesion by using adequate QCA software in the cath-lab in case of PCI; RT performance does not differ from SIC.
Collapse
|
46
|
Tomkowiak MT, Raval AN, Van Lysel MS, Funk T, Speidel MA. Calibration-Free Coronary Artery Measurements for Interventional Device Sizing using Inverse Geometry X-ray Fluoroscopy: In Vivo Validation. PROCEEDINGS OF SPIE--THE INTERNATIONAL SOCIETY FOR OPTICAL ENGINEERING 2014; 9033:90332H. [PMID: 24999298 PMCID: PMC4079058 DOI: 10.1117/12.2044078] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
Proper sizing of interventional devices to match coronary vessel dimensions improves procedural efficiency and therapeutic outcomes. We have developed a novel method using inverse geometry x-ray fluoroscopy to automatically determine vessel dimensions without the need for magnification calibration or optimal views. To validate this method in vivo, we compared results to intravascular ultrasound (IVUS) and coronary computed tomography angiography (CCTA) in a healthy porcine model. Coronary angiography was performed using Scanning-Beam Digital X-ray (SBDX), an inverse geometry fluoroscopy system that performs multiplane digital x-ray tomosynthesis in real time. From a single frame, 3D reconstruction of the arteries was performed by localizing the depth of vessel lumen edges. The 3D model was used to directly calculate length and to determine the best imaging plane to use for diameter measurements, where out-of-plane blur was minimized and the known pixel spacing was used to obtain absolute vessel diameter. End-diastolic length and diameter measurements were compared to measurements from CCTA and IVUS, respectively. For vessel segment lengths measuring 6 mm to 73 mm by CCTA, the SBDX length error was -0.49 ± 1.76 mm (SBDX - CCTA, mean ± 1 SD). For vessel diameters measuring 2.1 mm to 3.6 mm by IVUS, the SBDX diameter error was 0.07 ± 0.27 mm (SBDX - minimum IVUS diameter, mean ± 1 SD). The in vivo agreement between SBDX-based vessel sizing and gold standard techniques supports the feasibility of calibration-free coronary vessel sizing using inverse geometry x-ray fluoroscopy.
Collapse
|
47
|
Ribichini F, Romano M, Rosiello R, La Vecchia L, Cabianca E, Caramanno G, Milazzo D, Loschiavo P, Rigattieri S, Musarò S, Pironi B, Fiscella A, Amico F, Indolfi C, Spaccarotella C, Bartorelli A, Trabattoni D, Della Rovere F, Rolandi A, Beqaraj F, Belli R, Sangiorgio P, Villani R, Berni A, Sheiban I, Lopera Quijada MJ, Cappi B, Ribaldi L, Vassanelli C. A clinical and angiographic study of the XIENCE V everolimus-eluting coronary stent system in the treatment of patients with multivessel coronary artery disease: the EXECUTIVE trial (EXecutive RCT: evaluating XIENCE V in a multi vessel disease). JACC Cardiovasc Interv 2013; 6:1012-22. [PMID: 24055444 DOI: 10.1016/j.jcin.2013.05.016] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/02/2012] [Revised: 05/15/2013] [Accepted: 05/24/2013] [Indexed: 11/18/2022]
Abstract
OBJECTIVES This study sought to investigate the efficacy and performance of the XIENCE V everolimus-eluting stent (EES) (Abbott Vascular, Santa Clara, California) in the treatment of de novo coronary lesions in patients with 2- to 3-vessel multivessel coronary artery disease (MV-CAD). BACKGROUND Drug-eluting stents (DES) have emerged as an alternative to conventional coronary artery bypass surgery in patients with MV-CAD although first-generation DES yielded inferior efficacy and safety compared with surgery. METHODS Prospective, randomized (1:1), multicenter feasibility trial was designed to assess angiographic efficacy of EES compared with the TAXUS paclitaxel-eluting stent (PES) in 200 patients, and a prospective, open-label, single-arm, controlled registry was designed to analyze the clinical outcome of EES at 1-year follow-up in 400 MV-CAD patients. For the randomized trial, the primary endpoint was in-stent late loss at 9 months. For the registry, the primary endpoint was a composite of all-cause death, myocardial infarction, and ischemia-driven target vessel revascularization at 12 months. RESULTS The primary endpoint per single lesion was significantly lower in the EES group compared with the PES group (-0.03 ± 0.49 mm vs. 0.23 ± 0.51 mm, p = 0.001). Similar results were observed when analyzing all lesions (0.05 ± 0.51 mm vs. 0.24 ± 0.50 mm, p < 0.001). Clinical outcome at 1 year yielded a composite of major adverse cardiac events of 9.2% in the single-arm registry, and 11.1% and 16.5% in the EES and PES randomized groups, respectively (p = 0.30). CONCLUSIONS The EXECUTIVE trial was a randomized pilot trial dedicated to the comparison of the efficacy of 2 different DES among patients with 2- to 3-vessel MV-CAD. The study shows lower in-stent late loss at 9 months with the EES XIENCE V compared with the PES TAXUS Libertè, and a low major adverse cardiac event rate at 1 year in patients with 2-to 3-vessel MV-CAD. (EXECUTIVE [EXecutive RCT: Evaluating XIENCE V in a Multi Vessel Disease]; NCT00531011).
Collapse
|
48
|
Kubo T, Akasaka T, Shite J, Suzuki T, Uemura S, Yu B, Kozuma K, Kitabata H, Shinke T, Habara M, Saito Y, Hou J, Suzuki N, Zhang S. OCT compared with IVUS in a coronary lesion assessment: the OPUS-CLASS study. JACC Cardiovasc Imaging 2013; 6:1095-1104. [PMID: 24011777 DOI: 10.1016/j.jcmg.2013.04.014] [Citation(s) in RCA: 198] [Impact Index Per Article: 18.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/29/2012] [Revised: 03/27/2013] [Accepted: 04/18/2013] [Indexed: 12/14/2022]
Abstract
OBJECTIVES The aim of this study was to investigate the reliability of frequency domain optical coherence tomography (FD-OCT) for coronary measurements compared with quantitative coronary angiography (QCA) and intravascular ultrasound (IVUS). BACKGROUND Accurate luminal measurement is expected in FD-OCT because this technology offers high resolution and excellent contrast between lumen and vessel wall. METHODS In 5 medical centers, 100 patients with coronary artery disease were prospectively studied by using angiography, FD-OCT, and IVUS. In addition, 5 phantom models of known lumen dimensions (lumen diameter 3.08 mm; lumen area 7.45 mm(2)) were examined using FD-OCT and IVUS. Quantitative image analyses of the coronary arteries and phantom models were performed by an independent core laboratory. RESULTS In the clinical study, the mean minimum lumen diameter measured by QCA was significantly smaller than that measured by FD-OCT (1.81 ± 0.72 mm vs. 1.91 ± 0.69 mm; p < 0.001) and the minimum lumen diameter measured by IVUS was significantly greater than that measured by FD-OCT (2.09 ± 0.60 mm vs. 1.91 ± 0.69 mm; p < 0.001). The minimum lumen area measured by IVUS was significantly greater than that by FD-OCT (3.68 ± 2.06 mm(2) vs. 3.27 ± 2.22 mm(2); p < 0.001), although a significant correlation was observed between the 2 imaging techniques (r = 0.95, p < 0.001; mean difference 0.41 mm(2)). Both FD-OCT and IVUS exhibited good interobserver reproducibility, but the root-mean-squared deviation between measurements was approximately twice as high for the IVUS measurements compared with the FD-OCT measurements (0.32 mm(2) vs. 0.16 mm(2)). In a phantom model, the mean lumen area according to FD-OCT was equal to the actual lumen area of the phantom model, with low SD; IVUS overestimated the lumen area and was less reproducible than FD-OCT (8.03 ± 0.58 mm(2) vs. 7.45 ± 0.17 mm(2); p < 0.001). CONCLUSIONS The results of this prospective multicenter study demonstrate that FD-OCT provides accurate and reproducible quantitative measurements of coronary dimensions in the clinical setting.
Collapse
|
49
|
Yan RT, Miller JM, Rochitte CE, Dewey M, Niinuma H, Clouse ME, Vavere AL, Brinker J, Lima JAC, Arbab-Zadeh A. Predictors of inaccurate coronary arterial stenosis assessment by CT angiography. JACC Cardiovasc Imaging 2013; 6:963-72. [PMID: 23932641 PMCID: PMC4162406 DOI: 10.1016/j.jcmg.2013.02.011] [Citation(s) in RCA: 49] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/25/2012] [Revised: 01/16/2013] [Accepted: 02/21/2013] [Indexed: 11/29/2022]
Abstract
OBJECTIVES This study sought to investigate the clinical and imaging characteristics associated with diagnostic inaccuracy of computed tomography angiography (CTA) for detecting obstructive coronary artery disease (CAD) defined by quantitative coronary angiography (QCA). BACKGROUND Although diagnostic performance metrics of CTA have been reported, there are sparse data on predictors of diagnostic inaccuracy by CTA. METHODS The clinical characteristics of 291 patients (mean age: 59 ± 10 years; female: 25.8%) enrolled in the multicenter CorE-64 (Coronary Artery Evaluation Using 64-Row Multi-detector Computed Tomography Angiography) study were examined. Pre-defined CTA segment-level characteristics of all true-positive (N = 237), false-positive (N = 115), false-negative (FN) (N = 159), and a random subset of true-negative segments (N = 511) for ≥50% stenosis with QCA as the reference standard were blindly abstracted in a central core laboratory. Factors independently associated with corresponding levels of CTA diagnostic inaccuracies on a patient level and coronary artery segment level were determined using multivariable logistic regression models and generalized estimating equations, respectively. RESULTS An Agatston calcium score of ≥1 per patient (odds ratio [OR]: 5.2; 95% confidence interval [CI]: 1.1 to 24.6) and the presence of within-segment calcification (OR: 10.2; 95% CI: 5.2 to 19.8) predicted false-positive diagnoses. Conversely, absence of within-segment calcification was an independent predictor of an FN diagnosis (OR: 2.0; 95% CI: 1.2 to 3.5). Prior percutaneous revascularization was independently associated with patient-level misdiagnosis of obstructive CAD (OR: 4.2; 95% CI: 1.6 to 11.2). Specific segment characteristics on CTA, notably segment tortuosity (OR: 3.5; 95% CI: 2.4 to 5.1), smaller luminal caliber (OR: 0.48; 95% CI: 0.36 to 0.63 per 1-mm increment), and juxta-arterial vein conspicuity (OR: 2.1; 95% CI: 1.4 to 3.2), were independently associated with segment-level misdiagnoses. Attaining greater intraluminal contrast enhancement independently lowered the risk of an FN diagnosis (OR: 0.96; 95% CI: 0.94 to 0.99 per 10-Hounsfield unit increment). CONCLUSIONS We identified clinical and readily discernible imaging characteristics on CTA predicting inaccurate CTA diagnosis of obstructive CAD defined by QCA. Knowledge and appropriate considerations of these features may improve the diagnostic accuracy in clinical CTA interpretation. (Diagnostic Accuracy of Multi-Detector Spiral Computed Tomography Angiography Using 64 Detectors [CORE-64]; NCT00738218).
Collapse
|
50
|
Rahman S, Leesar T, Cilingiroglu M, Effat M, Arif I, Helmy T, Leesar MA. Impact of kissing balloon inflation on the main vessel stent volume, area, and symmetry after side-branch dilation in patients with coronary bifurcation lesions: a serial volumetric intravascular ultrasound study. JACC Cardiovasc Interv 2013; 6:923-31. [PMID: 23954062 DOI: 10.1016/j.jcin.2013.04.019] [Citation(s) in RCA: 46] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/21/2013] [Revised: 04/12/2013] [Accepted: 04/25/2013] [Indexed: 11/28/2022]
Abstract
OBJECTIVES Intravascular ultrasound (IVUS) was performed to investigate the impact of kissing balloon inflation (KBI) on the main vessel (MV) stent volume, area, and symmetry after side-branch (SB) dilation in patients with coronary bifurcation lesions (CBL). BACKGROUND It remains controversial whether KBI would restore the MV stent area and symmetry loss after SB dilation. METHODS A total of 88 serial IVUS examinations of the MV were performed after MV angioplasty, MV stenting, SB dilation, and KBI in 22 patients with CBL. The MV stent was divided into proximal, bifurcation, and distal segments; the stent volume index (SVI), minimal stent area (MSA), stent symmetry index (SSI), and external elastic membrane (EEM) volume index were measured in 198 stent segments and compared after MV stenting, SB dilation, and KBI. RESULTS In the bifurcation segment, SVI, MSA, and SSI were significantly smaller after SB dilation than after MV stenting and KBI (SVI was 6.10 ± 1.50 mm(3)/mm vs. 6.68 ± 1.60 mm(3)/mm and 6.57 ± 1.60 mm(3)/mm, respectively, p < 0.05; MSA was 5.15 ± 1.30 mm(2) vs. 6.08 ± 1.40 mm(2) and 5.86 ± 1.50 mm(2), respectively, p < 0.05; and SSI was 0.78 ± 0.02 mm(2) vs. 0.87 ± 0.03 mm(2) and 0.84 ± 0.03 mm(2), respectively, p < 0.05). KBI restored the MV SVI, MSA, and SSI after SB dilation. In the proximal segment, SVI, MSA, and EEM volume index were significantly larger, but SSI was smaller after KBI than after MV stenting and SB dilation. In the distal segment, neither SB dilation nor KBI had a significant impact on the MV stent volume or symmetry. CONCLUSIONS This is the first comprehensive volumetric IVUS analysis of CBL, to our knowledge, demonstrating that KBI restores the MV stent volume, area, and symmetry loss after SB dilation in the bifurcation segment, and induces asymmetric stent expansion in the proximal segment.
Collapse
|