26
|
Dixon NEJ, Monk SD, Graham J, Cheneler D. Compact Back-End Electronics with Temperature Compensation and Efficient Data Management for In Situ SiPM-Based Radiation Detection. SENSORS (BASEL, SWITZERLAND) 2023; 23:4053. [PMID: 37112392 PMCID: PMC10141715 DOI: 10.3390/s23084053] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/02/2023] [Revised: 04/08/2023] [Accepted: 04/11/2023] [Indexed: 06/19/2023]
Abstract
A compact back-end interface for silicon photomultipliers (SiPMs) implementing Zener diode-based temperature compensation has been developed for the remote detection of beta and gamma radiation. Remote detection is facilitated by the development of an efficient data management system utilising MySQL database storage for recording periodic spectra data for wireless access over a private Wi-Fi network. A trapezoidal peak shaping algorithm has been implemented on an FPGA for the continuous conversation of pulses from the SiPM, signifying the detection of a radiological particle, into spectra. This system has been designed to fit within a 46 mm cylindrical diameter for in situ characterization, and can be attached to one or more SiPMs used in conjunction with a range of scintillators. LED blink tests have been used to optimise the trapezoidal shaper coefficients to maximise the resolution of the recorded spectra. Experiments with an array of SiPMs integrated with a NaI(Tl) scintillator exposed to sealed sources of Co-60, Cs-137, Na-22 and Am-241 have shown that the detector achieves a peak efficiency of 27.09 ± 0.13% for a gamma peak at 59.54 keV produced by Am-241, and a minimum energy resolution (Delta E/E) of 4.27 ± 1.16% for the 1332.5 keV gamma peak from Co-60.
Collapse
|
27
|
Zeis B, Koch M, Gigengack U, Morawe T, Paul RJ. Limits of the thermal tolerance of two lentic crustaceans: The role of lactate dehydrogenase. JOURNAL OF EXPERIMENTAL ZOOLOGY. PART A, ECOLOGICAL AND INTEGRATIVE PHYSIOLOGY 2023. [PMID: 37042032 DOI: 10.1002/jez.2700] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Subscribe] [Scholar Register] [Received: 10/12/2022] [Revised: 03/25/2023] [Accepted: 03/27/2023] [Indexed: 04/13/2023]
Abstract
Limits of thermal tolerance in animal life is dependent on energy supply. Accordingly, the lowered ATP production capacity in ectotherms at high temperatures, which arises from a mismatch between oxygen supply and demand and the consequent switch from aerobic to anaerobic metabolism, affects the thermal resistance of these animals. The anaerobic ATP production capacity depends on the functional properties of the enzymes that reduce pyruvate. Thus, the present study focused on the role of the lactate dehydrogenase (LDH) of two daphnid species for anaerobic energy production at warm temperatures and the implications for their specific heat tolerances. Daphnia magna showed a higher thermal limit (indicated by immobilization time at 37°C) than Daphnia pulex, and in both species, this limit increased with rising acclimation temperature. In contrast to D. pulex, D. magna accumulated significant amounts of lactate at higher ambient temperatures. The intensity of anaerobic metabolism was also affected by acclimation temperature. Studying the functional enzyme properties revealed altered maximal reaction rates and substrate inhibitions of the LDH suites of the two daphnid species. D. magna LDH showed a significantly lower substrate inhibition than D. pulex LDH. The LDH isoform composition and the temperature-induced changes differed between both species. The detected qualitative modulations of the LDH suites may have resulted from differential isoform expression and different maturation processes. The species-specific LDH characteristics imply a higher anaerobic energy production at warm temperatures in D. magna, which likely contributes to the higher heat tolerance of this species.
Collapse
|
28
|
Wu S, Lv N, Geng Y, Chen X, Wang G, He S. Optical Fiber Fabry-Pérot Microfluidic Sensor Based on Capillary Fiber and Side Illumination Method. SENSORS (BASEL, SWITZERLAND) 2023; 23:3198. [PMID: 36991908 PMCID: PMC10053381 DOI: 10.3390/s23063198] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/13/2023] [Revised: 03/10/2023] [Accepted: 03/14/2023] [Indexed: 06/19/2023]
Abstract
In this paper, an optical fiber Fabry-Pérot (FP) microfluidic sensor based on the capillary fiber (CF) and side illumination method is designed. The hybrid FP cavity (HFP) is naturally formed by the inner air hole and silica wall of CF which is side illuminated by another single mode fiber (SMF). The CF acts as a naturally microfluidic channel, which can be served as a potential microfluidic solution concentration sensor. Moreover, the FP cavity formed by silica wall is insensitive to ambient solution refractive index but sensitive to the temperature. Thus, the HFP sensor can simultaneously measure microfluidic refractive index (RI) and temperature by cross-sensitivity matrix method. Three sensors with different inner air hole diameters were selected to fabricate and characterize the sensing performance. The interference spectra corresponding to each cavity length can be separated from each amplitude peak in the FFT spectra with a proper bandpass filter. Experimental results indicate that the proposed sensor with excellent sensing performance of temperature compensation is low-cost and easy to build, which is suitable for in situ monitoring and high-precision sensing of drug concentration and the optical constants of micro-specimens in the biomedical and biochemical fields.
Collapse
|
29
|
Lou Y, Yang T, Luo D, Wu J, Dong Y. A Novel Catheter Distal Contact Force Sensing for Cardiac Ablation Based on Fiber Bragg Grating with Temperature Compensation. SENSORS (BASEL, SWITZERLAND) 2023; 23:2866. [PMID: 36905071 PMCID: PMC10007298 DOI: 10.3390/s23052866] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/29/2023] [Revised: 02/19/2023] [Accepted: 03/03/2023] [Indexed: 06/18/2023]
Abstract
OBJECTIVE To accurately achieve distal contact force, a novel temperature-compensated sensor is developed and integrated into an atrial fibrillation (AF) ablation catheter. METHODS A dual elastomer-based dual FBGs structure is used to differentiate the strain on the two FBGs to achieve temperature compensation, and the design is optimized and validated by finite element simulation. RESULTS The designed sensor has a sensitivity of 90.5 pm/N, resolution of 0.01 N, and root-mean-square error (RMSE) of 0.02 N and 0.04 N for dynamic force loading and temperature compensation, respectively, and can stably measure distal contact forces with temperature disturbances. CONCLUSION Due to the advantages, i.e., simple structure, easy assembly, low cost, and good robustness, the proposed sensor is suitable for industrial mass production.
Collapse
|
30
|
Yuan B, Tang Z, Zhang P, Lv F. Thermal Calibration of Triaxial Accelerometer for Tilt Measurement. SENSORS (BASEL, SWITZERLAND) 2023; 23:2105. [PMID: 36850700 PMCID: PMC9964833 DOI: 10.3390/s23042105] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/27/2022] [Revised: 02/09/2023] [Accepted: 02/10/2023] [Indexed: 06/18/2023]
Abstract
The application of MEMS accelerometers used to measure inclination is constrained by their temperature dependence, and each accelerometer needs to be calibrated individually to increase stability and accuracy. This paper presents a calibration and thermal compensation method for triaxial accelerometers that aims to minimize cost and processing time while maintaining high accuracy. First, the number of positions to perform the calibration procedure is optimized based on the Levenberg-Marquardt algorithm, and then, based on this optimized calibration number, thermal compensation is performed based on the least squares method, which is necessary for environments with large temperature variations, since calibration parameters change at different temperatures. The calibration procedures and algorithms were experimentally validated on marketed accelerometers. Based on the optimized calibration method, the calibrated results achieved nearly 100 times improvement. Thermal drift calibration experiments on the triaxial accelerometer show that the thermal compensation scheme in this paper can effectively reduce drift in the temperature range of -40 °C to 60 °C. The temperature drifts of x- and y-axes are reduced from -13.2 and 11.8 mg to -0.9 and -1.1 mg, respectively. The z-axis temperature drift is reduced from -17.9 to 1.8 mg. We have conducted various experiments on the proposed calibration method and demonstrated its capacity to calibrate the sensor frame error model (SFEM) parameters. This research proposes a new low-cost and efficient strategy for increasing the practical applicability of triaxial accelerometers.
Collapse
|
31
|
Wang B, Stevenson EL, Dunlap JC. Functional analysis of 110 phosphorylation sites on the circadian clock protein FRQ identifies clusters determining period length and temperature compensation. G3 (BETHESDA, MD.) 2023; 13:jkac334. [PMID: 36537198 PMCID: PMC9911066 DOI: 10.1093/g3journal/jkac334] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/08/2022] [Revised: 11/13/2022] [Accepted: 12/12/2022] [Indexed: 12/24/2022]
Abstract
In the negative feedback loop driving the Neurospora circadian oscillator, the negative element, FREQUENCY (FRQ), inhibits its own expression by promoting phosphorylation of its heterodimeric transcriptional activators, White Collar-1 (WC-1) and WC-2. FRQ itself also undergoes extensive time-of-day-specific phosphorylation with over 100 phosphosites previously documented. Although disrupting individual or certain clusters of phosphorylation sites has been shown to alter circadian period lengths to some extent, it is still elusive how all the phosphorylations on FRQ control its activity. In this study, we systematically investigated the role in period determination of all 110 reported FRQ phosphorylation sites, using mutagenesis and luciferase reporter assays. Surprisingly, robust FRQ phosphorylation is still detected even when 84 phosphosites were eliminated altogether; further mutating another 26 phosphoresidues completely abolished FRQ phosphorylation. To identify phosphoresidue(s) on FRQ impacting circadian period length, a series of clustered frq phosphomutants covering all the 110 phosphosites were generated and examined for period changes. When phosphosites in the N-terminal and middle regions of FRQ were eliminated, longer periods were typically seen while removal of phosphorylation in the C-terminal tail resulted in extremely short periods, among the shortest reported. Interestingly, abolishing the 11 phosphosites in the C-terminal tail of FRQ not only results in an extremely short period, but also impacts temperature compensation (TC), yielding an overcompensated circadian oscillator. In addition, the few phosphosites in the middle of FRQ are also found to be crucial for TC. When different groups of FRQ phosphomutations were combined intramolecularly, expected additive effects were generally observed except for one novel case of intramolecular epistasis, where arrhythmicity resulting from one cluster of phosphorylation site mutants was restored by eliminating phosphorylation at another group of sites.
Collapse
|
32
|
Baral S, Negi P, Adhikari S, Bhalla S. Temperature Compensation for Reusable Piezo Configuration for Condition Monitoring of Metallic Structures: EMI Approach. SENSORS (BASEL, SWITZERLAND) 2023; 23:s23031587. [PMID: 36772627 PMCID: PMC9918941 DOI: 10.3390/s23031587] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/22/2022] [Revised: 01/23/2023] [Accepted: 01/28/2023] [Indexed: 05/27/2023]
Abstract
This paper presents a novel algorithm for compensating the changes in conductance signatures of a piezo sensor due to the temperature variation employed in condition monitoring using the electro-mechanical impedance (EMI) approach. It is crucial to consider the changes in an EMI signature due to temperature before using it for comparison with the baseline signature. The shifts in the signature due to temperature can be misinterpreted as damages to the structure, which might also result in a false alarm. In the present study, the compensation values are calculated based on experiments on piezo sensors both in a free boundary condition and in a bonded condition on a metallic host structure. The values were further validated experimentally for damage detection on a large 2D steel plate structure. The variation in first natural frequency values for the unbonded piezo sensor at different temperatures has been used to develop the compensation algorithms. Whereas, in the case of the bonded sensor, the shift in structural peaks has been used. The developed compensation relations showed promising results in damage detection. Lastly, a finite element-based study has also been performed, supporting the experimental findings. The outcome of this study will aid in the compensation of the signatures in the structure due to temperature variation in the conductance signature.
Collapse
|
33
|
Giesecke A, Johnstone PS, Lamaze A, Landskron J, Atay E, Chen KF, Wolf E, Top D, Stanewsky R. A novel period mutation implicating nuclear export in temperature compensation of the Drosophila circadian clock. Curr Biol 2023; 33:336-350.e5. [PMID: 36584676 DOI: 10.1016/j.cub.2022.12.011] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2022] [Revised: 10/14/2022] [Accepted: 12/06/2022] [Indexed: 12/30/2022]
Abstract
Circadian clocks are self-sustained molecular oscillators controlling daily changes of behavioral activity and physiology. For functional reliability and precision, the frequency of these molecular oscillations must be stable at different environmental temperatures, known as "temperature compensation." Despite being an intrinsic property of all circadian clocks, this phenomenon is not well understood at the molecular level. Here, we use behavioral and molecular approaches to characterize a novel mutation in the period (per) clock gene of Drosophila melanogaster, which alters a predicted nuclear export signal (NES) of the PER protein and affects temperature compensation. We show that this new perI530A allele leads to progressively longer behavioral periods and clock oscillations with increasing temperature in both clock neurons and peripheral clock cells. While the mutant PERI530A protein shows normal circadian fluctuations and post-translational modifications at cool temperatures, increasing temperatures lead to both severe amplitude dampening and hypophosphorylation of PERI530A. We further show that PERI530A displays reduced repressor activity at warmer temperatures, presumably because it cannot inactivate the transcription factor CLOCK (CLK), indicated by temperature-dependent altered CLK post-translational modification in perI530A flies. With increasing temperatures, nuclear accumulation of PERI530A within clock neurons is increased, suggesting that wild-type PER is exported out of the nucleus at warm temperatures. Downregulating the nuclear export factor CRM1 also leads to temperature-dependent changes of behavioral rhythms, suggesting that the PER NES and the nuclear export of clock proteins play an important role in temperature compensation of the Drosophila circadian clock.
Collapse
|
34
|
Din H, Iqbal F, Park J, Lee B. Bias-Repeatability Analysis of Vacuum-Packaged 3-Axis MEMS Gyroscope Using Oven-Controlled System. SENSORS (BASEL, SWITZERLAND) 2022; 23:256. [PMID: 36616854 PMCID: PMC9824465 DOI: 10.3390/s23010256] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/07/2022] [Revised: 12/21/2022] [Accepted: 12/23/2022] [Indexed: 06/17/2023]
Abstract
The performance of microelectromechanical system (MEMS) inertial measurement units (IMUs) is susceptible to many environmental factors. Among different factors, temperature is one of the most challenging issues. This report reveals the bias stability analysis of an ovenized MEMS gyroscope. A micro-heater and a control system exploiting PID/PWM were used to compensate for the bias stability variations of a commercial MEMS IMU from BOSCH "BMI 088". A micro-heater made of gold (Au) thin film is integrated with the commercial MEMS IMU chip. A custom-designed micro-machined glass platform thermally isolates the MEMS IMU from the ambient environment and is vacuum sealed in the leadless chip carrier (LCC) package. The BMI 088 built-in temperature sensor is used for temperature sensing of the device and the locally integrated heater. The experimental results reveal that the bias repeatability of the devices has been improved significantly to achieve the target specifications, making the commercial devices suitable for navigation. Furthermore, the effect of vacuum-packaged and non-vacuum-packaged devices was compared. It was found that the bias repeatability of vacuum-packaged devices was improved by more than 60%.
Collapse
|
35
|
Pereira L, Min R, Woyessa G, Bang O, Marques C, Varum H, Antunes P. Interrogation Method with Temperature Compensation Using Ultra-Short Fiber Bragg Gratings in Silica and Polymer Optical Fibers as Edge Filters. SENSORS (BASEL, SWITZERLAND) 2022; 23:23. [PMID: 36616621 PMCID: PMC9823740 DOI: 10.3390/s23010023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/18/2022] [Revised: 12/12/2022] [Accepted: 12/16/2022] [Indexed: 06/17/2023]
Abstract
The use of simpler and less bulky equipment, with a reliable performance and at relative low cost is increasingly important when assembling sensing configurations for a wide variety of applications. Based on this concept, this paper proposes a simple, efficient and relative low-cost fiber Bragg grating (FBG) interrogation solution using ultra-short FBGs (USFBGs) as edge filters. USFBGs with different lengths and reflection bandwidths were produced in silica optical fiber and in poly(methyl methacrylate) (PMMA) microstructured polymer optical fiber (mPOF), and by adjusting specific inscription parameters and the diffraction pattern, these gratings can present self-apodization and unique spectral characteristics suitable for filtering operations. In addition to being a cost-effective edge filter solution, USFBGs and standard uniform FBGs in silica fiber have similar thermal sensitivities, which results in a straightforward operation without complex equipment or calculations. This FBG interrogation configuration is also quite promising for dynamic measurements, and due to its multiplexing capabilities multiple USFBGs can be inscribed in the same optical fiber, allowing to incorporate several filters with identical or different spectral characteristics at specific wavelength regions in the same fiber, thus showing great potential to create and develop new sensing configurations.
Collapse
|
36
|
Thakkar N, Giesecke A, Bazalova O, Martinek J, Smykal V, Stanewsky R, Dolezel D. Evolution of casein kinase 1 and functional analysis of new doubletime mutants in Drosophila. Front Physiol 2022; 13:1062632. [PMID: 36589447 PMCID: PMC9794997 DOI: 10.3389/fphys.2022.1062632] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2022] [Accepted: 11/28/2022] [Indexed: 12/23/2022] Open
Abstract
Circadian clocks are timing devices that rhythmically adjust organism's behavior, physiology, and metabolism to the 24-h day-night cycle. Eukaryotic circadian clocks rely on several interlocked transcription-translation feedback loops, where protein stability is the key part of the delay between transcription and the appearance of the mature proteins within the feedback loops. In bilaterian animals, including mammals and insects, the circadian clock depends on a homologous set of proteins. Despite mostly conserved clock components among the fruit fly Drosophila and mammals, several lineage-specific differences exist. Here we have systematically explored the evolution and sequence variability of insect DBT proteins and their vertebrate homologs casein kinase 1 delta (CKIδ) and epsilon (CKIε), dated the origin and separation of CKIδ from CKIε, and identified at least three additional independent duplications of the CKIδ/ε gene in Petromyzon, Danio, and Xenopus. We determined conserved regions in DBT specific to Diptera, and functionally tested a subset of those in D. melanogaster. Replacement of Lysine K224 with acidic residues strongly impacts the free-running period even in heterozygous flies, whereas homozygous mutants are not viable. K224D mutants have a temperature compensation defect with longer free-running periods at higher temperatures, which is exactly the opposite trend of what was reported for corresponding mammalian mutants. All DBTs of dipteran insects contain the NKRQK motif at positions 220-224. The occurrence of this motif perfectly correlates with the presence of BRIDE OF DOUBLETIME, BDBT, in Diptera. BDBT is a non-canonical FK506-binding protein that physically interacts with Drosophila DBT. The phylogeny of FK506-binding proteins suggests that BDBT is either absent or highly modified in non-dipteran insects. In addition to in silico analysis of DBT/CKIδ/ε evolution and diversity, we have identified four novel casein kinase 1 genes specific to the Drosophila genus.
Collapse
|
37
|
Park JH, Ji SM, Choi JM, Joun MS. Accurate Flow Characterization of A6082 for Precision Simulation of a Hot Metal Forming Process. MATERIALS (BASEL, SWITZERLAND) 2022; 15:8656. [PMID: 36500158 PMCID: PMC9735618 DOI: 10.3390/ma15238656] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/27/2022] [Revised: 11/25/2022] [Accepted: 11/28/2022] [Indexed: 06/17/2023]
Abstract
The flow behaviors of metallic materials are sensitive to state variables, including strain, strain rate, and temperature. In particular, the temperature effect on the flow behavior is of great importance. The flow information is usually obtained at the sample strain rates and temperatures from the hot cylinder compression test. However, this test is inevitably exposed to undesirable effects of friction and temperature on flow characterization. This study reveals their impact on the flow curve of an A6082 alloy. The unique features of its flow behavior and the inaccuracy of as-received, primitive flow information are emphasized. Using a systematic way of correcting the friction and temperature effects, the flow curves with high accuracy in terms of the compression load-stroke curve obtained from the test are calculated. It was revealed that the both the friction and temperature compensation of the primitive flow curves bring a minor change in the flow curves of the A6082 alloy, which is quite different from other commercial light metals. This phenomenon caused by the unique features of the flow behavior of the A6082 or other aluminum alloys will be critical to solving various process and quality matters confronted by the engineers in the hot metal forming industry.
Collapse
|
38
|
Mu S, Chan PK. Design of Precision-Aware Subthreshold-Based MOSFET Voltage Reference. SENSORS (BASEL, SWITZERLAND) 2022; 22:9466. [PMID: 36502168 PMCID: PMC9741424 DOI: 10.3390/s22239466] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/11/2022] [Revised: 11/30/2022] [Accepted: 12/01/2022] [Indexed: 06/17/2023]
Abstract
A new precision-aware subthreshold-based MOSFET voltage reference is presented in this paper. The circuit was implemented TSMC-40 nm process technology. It consumed 9.6 μW at the supply voltage of 1.2 V. In this proposed work, by utilizing subthreshold-based MOSFET instead of bipolar junction transistor (BJT), relatively lower power consumption was obtained in the design while offering comparable precision to that offered by its BJT counterpart. Through the proposed second-order compensation, it achieved the temperature coefficient (T.C.) of 3.0 ppm/°C in the TT corner case and a 200-sample Monte-Carlo T.C. of 12.51 ppm/°C from -40 °C to 90 °C. This shows robust temperature insensitivity. The process sensitivity of Vref without and with trimming was 2.85% and 0.75%, respectively. The power supply rejection (PSR) was 71.65 dB at 100 Hz and 52.54 dB at 10 MHz. The Figure-of-Merit (FOM) for the total variation in output voltage was comparable with representative BJT circuits and better than subthreshold-based MOSFET circuits. Due to low T.C., low process sensitivity, and simplicity of the circuit architecture, the proposed work will be useful for sensor circuits with stringent requirements or other analog circuits that require high precision applications.
Collapse
|
39
|
Wang X, Cao H. Improved VMD-ELM Algorithm for MEMS Gyroscope of Temperature Compensation Model Based on CNN-LSTM and PSO-SVM. MICROMACHINES 2022; 13:2056. [PMID: 36557354 PMCID: PMC9781447 DOI: 10.3390/mi13122056] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/17/2022] [Revised: 11/14/2022] [Accepted: 11/16/2022] [Indexed: 06/17/2023]
Abstract
The micro-electro-mechanical system (MEMS) gyroscope is a micro-mechanical gyroscope with low cost, small volume, and good reliability. The working principle of the MEMS gyroscope, which is achieved through Coriolis, is different from traditional gyroscopes. The MEMS gyroscope has been widely used in the fields of micro-inertia navigation systems, military, automotive, consumer electronics, mobile applications, robots, industrial, medical, and other fields in micro-inertia navigation systems because of its advantages of small volume, good performance, and low price. The material characteristics of the MEMS gyroscope is very significant for its data output, and the temperature determines its accuracy and limits its further application. In order to eliminate the effect of temperature, the MEMS gyroscope needs to be compensated to improve its accuracy. This study proposed an improved variational modal decomposition-extreme learning machine (VMD-ELM) algorithm based on convolutional neural networks-long short-term memory (CNN-LSTM) and particle swarm optimization-support vector machines (PSO-SVM). By establishing a temperature compensation model, the gyro temperature output signal is optimized and reconstructed, and the gyro output signal with better accuracy is obtained. The VMD algorithm separates the gyro output signal and divides the gyro output signal into low-frequency signals, mid-frequency signals, and high-frequency signals according to the different signal frequencies. Once again, the PSO-SVM model is constructed by the mid-frequency temperature signal to find the temperature error. Finally, the signal is reconstructed through the ELM neural network algorithm, and then, the gyro output signal after noise is obtained. Experimental results show that, by using the improved method, the output of the MEMS gyroscope ranging from -40 to 60 °C reduced, and the temperature drift dramatically declined. For example, the factor of quantization noise (Q) reduced from 1.2419 × 10-4 to 1.0533 × 10-6, the factor of bias instability (B) reduced from 0.0087 to 1.8772 × 10-4, and the factor of random walk of angular velocity (N) reduced from 2.0978 × 10-5 to 1.4985 × 10-6. Furthermore, the output of the MEMS gyroscope ranging from 60 to -40 °C reduced. The factor of Q reduced from 2.9808 × 10-4 to 2.4430 × 10-6, the factor of B reduced from 0.0145 to 7.2426 × 10-4, and the factor of N reduced from 4.5072 × 10-5 to 1.0523 × 10-5. The improved algorithm can be adopted to denoise the output signal of the MEMS gyroscope to improve its accuracy.
Collapse
|
40
|
Wang H, Li J. Machine Learning and Swarm Optimization Algorithm in Temperature Compensation of Pressure Sensors. SENSORS (BASEL, SWITZERLAND) 2022; 22:8309. [PMID: 36366005 PMCID: PMC9654921 DOI: 10.3390/s22218309] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/06/2022] [Revised: 10/12/2022] [Accepted: 10/26/2022] [Indexed: 06/16/2023]
Abstract
The main temperature compensation method for MEMS piezoresistive pressure sensors is software compensation, which processes the sensor data using various algorithms to improve the output accuracy. However, there are few algorithms designed for sensors with specific ranges, most of which ignore the operating characteristics of the sensors themselves. In this paper, we propose three temperature compensation methods based on swarm optimization algorithms fused with machine learning for three different ranges of sensors and explore the partitioning ratio of the calibration dataset on Sensor A. The results show that different algorithms are suitable for pressure sensors of different ranges. An optimal compensation effect was achieved on Sensor A when the splitting ratio was 33.3%, where the zero-drift coefficient was 2.88 × 10-7/°C and the sensitivity temperature coefficient was 4.52 × 10-6/°C. The algorithms were compared with other algorithms in the literature to verify their superiority. The optimal segmentation ratio obtained from the experimental investigation is consistent with the sensor operating temperature interval and exhibits a strong innovation.
Collapse
|
41
|
Wang SC, Xie BR, Huang SM. Design and Analysis of Small Size Eddy Current Displacement Sensor. SENSORS (BASEL, SWITZERLAND) 2022; 22:s22197444. [PMID: 36236543 PMCID: PMC9573516 DOI: 10.3390/s22197444] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/22/2022] [Revised: 09/23/2022] [Accepted: 09/28/2022] [Indexed: 05/27/2023]
Abstract
A systematic method is employed for the design and analysis of a small size eddy current (EC) displacement sensor. Simulations are first performed to determine the optimal winding structure and dimensions of the sensor. A linear-fitting approach is then developed for converting the AC displacement signal of the sensor to a DC signal. Finally, a compensation method is proposed for mitigating the temperature drift of the EC sensor under different working temperatures. The experimental results show that the proposed sensor has a sensitivity of approximately 3 μm, a working temperature range of 25-55 °C, and a linearity of ±1.025%.
Collapse
|
42
|
Landskron J, Dötzer F, Benkert A, Mayle M, Drese KS. Acoustic Limescale Layer and Temperature Measurement in Ultrasonic Flow Meters. SENSORS (BASEL, SWITZERLAND) 2022; 22:6648. [PMID: 36081105 PMCID: PMC9460453 DOI: 10.3390/s22176648] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/06/2022] [Revised: 08/26/2022] [Accepted: 08/31/2022] [Indexed: 06/15/2023]
Abstract
Guided acoustic waves are commonly used in domestic water meters to measure the flow rate. The accuracy of this measurement method is affected by factors such as variations in temperature and limescale deposition inside of the pipe. In this work, a new approach using signals from different sound propagation paths is used to determine these quantities and allow for subsequent compensation. This method evaluates the different propagation times of guided Lamb waves in flow measurement applications. A finite element method-based model is used to identify the calibration curves for the device under test. The simulated dependencies on temperature and layer thickness are validated by experimental data. Finally, a test on simulated data with varying temperatures and limescale depositions proves that this method can be used to separate both effects. Based on these values, a flow measurement correction scheme can be derived that provides an improved resolution of guided acoustic wave-based flow meters.
Collapse
|
43
|
Wang K, Xiong X, Wang Z, Cai P, Ma L, Zou X. Utilizing the Intrinsic Mode of Weakly Coupled Resonators for Temperature Compensation. MICROMACHINES 2022; 13:1447. [PMID: 36144070 PMCID: PMC9502279 DOI: 10.3390/mi13091447] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/06/2022] [Revised: 08/26/2022] [Accepted: 08/30/2022] [Indexed: 06/16/2023]
Abstract
Accelerometers based on outputting amplitude ratios in weakly coupled resonators (WCRs) are attractive because their parametric sensitivity is higher by two or three orders of magnitudes than those based on outputting frequency. However, the impact of temperature on the coupler is a key factor in accelerometer applications. This paper proposed a novel mode-localized WCR accelerometer with a temperature compensation mechanism, with sensitive elements incorporating a double-ended tuning fork (DETF) resonator, clamped-clamped (CC) resonator, and a micro-lever coupler. The DETF out-of-phase mode is utilized, which is only sensitive to temperature, to measure the temperature change of WCRs and complete the temperature compensation using the compensation algorithm. This proposed method has no time delay in measuring the temperature of sensitive elements and no temperature difference caused by the uneven temperature field. The parametric sensitivity in amplitude ratio (AR) to acceleration drifting with temperature was theoretically analyzed, and the novel device was designed and fabricated by a silicon-on-glass process. Both simulation and experiment results demonstrated that the coupling stiffness drifted with temperature, which resulted in the drifts of its sensitivity to acceleration and zero-bias stability. Using the intrinsic mode of WCRs, in terms of the DETF out-of-phase mode, as an in situ thermometer and carrying out the temperature compensation algorithm, the drift of zero bias could be suppressed from 102 mg to 4.5 mg (g is the gravity acceleration), and the drift of the parameter sensitivity in AR was suppressed from 0.74 AR/g to 0.02 AR/g with the temperature range from 330 K to 370 K and acceleration range from 0 g to 0.2 g.
Collapse
|
44
|
Wang WL, Liu Q, Liu ZY, Wu Q, Fu YQ. Simulation of a Temperature-Compensated Voltage Sensor Based on Photonic Crystal Fiber Infiltrated with Liquid Crystal and Ethanol. SENSORS (BASEL, SWITZERLAND) 2022; 22:6374. [PMID: 36080831 PMCID: PMC9460568 DOI: 10.3390/s22176374] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/05/2022] [Revised: 08/12/2022] [Accepted: 08/22/2022] [Indexed: 06/15/2023]
Abstract
A simulated design for a temperature-compensated voltage sensor based on photonic crystal fiber (PCF) infiltrated with liquid crystal and ethanol is presented in this paper. The holes distributed across the transverse section of the PCF provide two channels for mode coupling between the liquid crystal or ethanol and the fiber core. The couplings are both calculated accurately and explored theoretically using the finite element method (FEM). The influence of voltage on the alignment of the liquid crystal molecules and confinement loss of the fiber mode are studied. Liquid crystal molecules rotate which changes its properties as the voltage changes. As the characteristics of the liquid crystal will be affected by temperature, therefore, we further fill using ethanol, which is merely sensitive to temperature, into one hole of the PCF to realize temperature compensation. The simulated results show that the sensitivity is up to 1.29977 nm/V with the temperature of 25 °C when the voltage ranges from 365 to 565 V. The standard deviation of the wavelength difference is less than 2 nm within the temperature adjustment from 25 to 50 °C for temperature compensation. The impacts of the construction parameters of the PCF on sensing performances of this voltage sensor are also analyzed in this paper.
Collapse
|
45
|
Wang H, Zeng Q, Zhang Z, Wang H. Research on Temperature Compensation of Multi-Channel Pressure Scanner Based on an Improved Cuckoo Search Optimizing a BP Neural Network. MICROMACHINES 2022; 13:1351. [PMID: 36014273 PMCID: PMC9412251 DOI: 10.3390/mi13081351] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/01/2022] [Revised: 08/14/2022] [Accepted: 08/18/2022] [Indexed: 06/15/2023]
Abstract
A multi-channel pressure scanner is an essential tool for measuring and acquiring various pressure parameters in aerospace applications. It is important to note, however, that the pressure sensor of each of these channels will drift significantly with the increase in the temperature range of the pressure measurement, and the output voltage of each of these channels will show nonlinear characteristics, which will constrain the improvements in the accuracy of the measurement. In the regression fitting process, it is difficult to fit nonlinear data with the traditional least-squares method, which leaves pressure measurement accuracy unsatisfactory. A temperature compensation method based on an improved cuckoo search optimizing a BP neural network for a multi-channel pressure scanner is proposed in this paper to improve pressure measurement accuracy in a wide temperature range. Using the chaotic simplex algorithm, we first improved the cuckoo search algorithm, then optimized the connection weights and thresholds of the BP neural network, and finally constructed an experimental calibration system to investigate the temperature compensation of the multi-channel pressure scanning valves in the -40 °C to 60 °C temperature range. The compensation test results show that the algorithm has a better compensation effect and is more suitable for the temperature compensation of multi-channel pressure scanners than the traditional least-squares method and the standard RBF and BP neural networks. The maximum full-scale error of all 32 channels is 0.02% FS (full-scale error) and below, which realizes its high-accuracy multi-point pressure measurement in a wide temperature range.
Collapse
|
46
|
Matko V. Multiple Quartz Crystals Connected in Parallel for High-Resolution Sensing of Capacitance Changes. SENSORS 2022; 22:s22135030. [PMID: 35808525 PMCID: PMC9269720 DOI: 10.3390/s22135030] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/21/2022] [Revised: 06/29/2022] [Accepted: 06/30/2022] [Indexed: 12/10/2022]
Abstract
We present a new highly sensitive, low-value capacitance sensor method that uses multiple quartz crystals connected in parallel inside the oscillator. In the experimental setup, the measured (sensible) reactance (capacitance) is connected in parallel to the total shunt capacitance of the quartz crystals, oscillating in the oscillator. Because AT-cut crystals have a certain nonlinear frequency−temperature dependence, we use the switching mode method, by which we achieve a temperature compensation of the AT-cut crystals’ frequency−temperature characteristics in the temperature range between 0−50 °C. The oscillator switching method also compensates for any other influences on the frequency of the oscillator, such as ageing of the crystals and oscillator elements, supply voltage fluctuations, and other parasitic impedances in the oscillating circuit. Subsequently using two 50-ms-delayed switches between the measuring and reference capacitors, the experimental error in measuring the capacitance is lowered for measurements under a dynamic temperature variation in the range of 0−50 °C. The experimental results show that the switching method, which includes a multiple quartz connection and high-temperature compensation improvement of the quartz crystals’ characteristics, enables a sub-aF resolution. It converts capacitance changes in the range 10 zF−200 fF to frequencies in the range 4 kHz−100 kHz.
Collapse
|
47
|
Li X, Gao L, Cao H, Sun Y, Jiang M, Zhang Y. A Temperature Compensation Method for aSix-Axis Force/Torque Sensor Utilizing Ensemble hWOA-LSSVM Based on Improved Trimmed Bagging. SENSORS (BASEL, SWITZERLAND) 2022; 22:s22134809. [PMID: 35808305 PMCID: PMC9268780 DOI: 10.3390/s22134809] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/01/2022] [Revised: 06/17/2022] [Accepted: 06/21/2022] [Indexed: 06/13/2023]
Abstract
The performance of a six-axis force/torque sensor (F/T sensor) severely decreased when working in an extreme environment due to its sensitivity to ambient temperature. This paper puts forward an ensemble temperature compensation method based on the whale optimization algorithm (WOA) tuning the least-square support vector machine (LSSVM) and trimmed bagging. To be specific, the stimulated annealing algorithm (SA) was hybridized to the WOA to solve the local entrapment problem, and an adaptive trimming strategy is proposed to obtain the optimal trim portion for the trimmed bagging. In addition, inverse quote error (invQE) and cross-validation are employed to estimate the fitness better in training process. The maximum absolute measurement error caused by temperature decreased from 3.34% to 3.9×10-3% of full scale after being compensated by the proposed method. The analyses of experiments illustrate the ensemble hWOA-LSSVM based on improved trimmed bagging improves the precision and stability of F/T sensors and possesses the strengths of local search ability and better adaptability.
Collapse
|
48
|
Joshi R, Cai YD, Xia Y, Chiu JC, Emery P. PERIOD Phosphoclusters Control Temperature Compensation of the Drosophila Circadian Clock. Front Physiol 2022; 13:888262. [PMID: 35721569 PMCID: PMC9201207 DOI: 10.3389/fphys.2022.888262] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2022] [Accepted: 04/29/2022] [Indexed: 11/13/2022] Open
Abstract
Ambient temperature varies constantly. However, the period of circadian pacemakers is remarkably stable over a wide-range of ecologically- and physiologically-relevant temperatures, even though the kinetics of most biochemical reactions accelerates as temperature rises. This thermal buffering phenomenon, called temperature compensation, is a critical feature of circadian rhythms, but how it is achieved remains elusive. Here, we uncovered the important role played by the Drosophila PERIOD (PER) phosphodegron in temperature compensation. This phosphorylation hotspot is crucial for PER proteasomal degradation and is the functional homolog of mammalian PER2 S478 phosphodegron, which also impacts temperature compensation. Using CRISPR-Cas9, we introduced a series of mutations that altered three Serines of the PER phosphodegron. While all three Serine to Alanine substitutions lengthened period at all temperatures tested, temperature compensation was differentially affected. S44A and S45A substitutions caused undercompensation, while S47A resulted in overcompensation. These results thus reveal unexpected functional heterogeneity of phosphodegron residues in thermal compensation. Furthermore, mutations impairing phosphorylation of the per s phosphocluster showed undercompensation, consistent with its inhibitory role on S47 phosphorylation. We observed that S47A substitution caused increased accumulation of hyper-phosphorylated PER at warmer temperatures. This finding was corroborated by cell culture assays in which S47A slowed down phosphorylation-dependent PER degradation at high temperatures, causing PER degradation to be excessively temperature-compensated. Thus, our results point to a novel role of the PER phosphodegron in temperature compensation through temperature-dependent modulation of the abundance of hyper-phosphorylated PER. Our work reveals interesting mechanistic convergences and differences between mammalian and Drosophila temperature compensation of the circadian clock.
Collapse
|
49
|
Jeon SJ, Park SY, Kim ST. Temperature Compensation of Fiber Bragg Grating Sensors in Smart Strand. SENSORS 2022; 22:s22093282. [PMID: 35590971 PMCID: PMC9106026 DOI: 10.3390/s22093282] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/28/2022] [Revised: 04/20/2022] [Accepted: 04/21/2022] [Indexed: 02/01/2023]
Abstract
Compared to other types of sensors, fiber optic sensors have improved accuracy and durability. Recently, the Smart Strand was developed to maximize the advantages of fiber optic sensors for measuring the cable forces in prestressed concrete structures or cable-supported bridges. The Smart Strand has fiber Bragg gratings (FBGs) embedded in a core wire of the seven-wire strand. Similar to other sensors, the strain measured at an FBG is affected by temperature; therefore, the temperature effect that is not related to the mechanical strain should be compensated for or corrected in the long-term measurement subjected to temperature variation. However, a temperature compensation procedure for the FBG has yet to be established, and relevant studies have used different formulas for the compensation. Moreover, when the FBG sensors are packaged with a certain material-such as fiber reinforced polymer-for protection, it is important to consider the interaction between the FBG, packaging material, and host material during thermal behavior. Therefore, this study proposed a reasonable procedure for temperature compensation for the FBG sensors embedded in packaging material and host material. In particular, the thermal sensitivity of the Smart Strand was intensively investigated. The proposed theoretical formulas were validated through comparison with data obtained from various specimens in a temperature-controlled chamber. Finally, the procedure was applied to correct the data measured using the Smart Strands in a 20-m-long full-scale specimen for about a year, thus resulting in a realistic trend of the long-term prestressing force.
Collapse
|
50
|
Li R, Liu Z, Yuan S, Zhu Z, Ye J, Zhang X. [Infrared Sensor ZTP-135SR and Its Application in Infrared Body Temperature Measurement]. ZHONGGUO YI LIAO QI XIE ZA ZHI = CHINESE JOURNAL OF MEDICAL INSTRUMENTATION 2022; 46:160-163. [PMID: 35411742 DOI: 10.3969/j.issn.1671-7104.2022.02.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Body temperature is an essential physiological parameter. Conducting non-contact, fast and accurate measurement of temperature is increasing important under the background of COVID-19. The study introduces an infrared temperature measurement system based on the thermopile infrared temperature sensor ZTP-135SR. Extracting original temperature date of sensor, post-amplification and filter processing have been performed to ensure accuracy of the system. In addition, the temperature data of environmental compensation which obtained by polynomial fitting is added to the system to further improve measurement accuracy.
Collapse
|