26
|
Kowalski R, Lee MGY, Doyle LW, Cheong JLY, Smolich JJ, d'Udekem Y, Mynard JP, Cheung MMH. Reduced Aortic Distensibility is Associated With Higher Aorto-Carotid Wave Transmission and Central Aortic Systolic Pressure in Young Adults After Coarctation Repair. J Am Heart Assoc 2019; 8:e011411. [PMID: 30929595 PMCID: PMC6509708 DOI: 10.1161/jaha.118.011411] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/07/2018] [Accepted: 01/31/2019] [Indexed: 01/09/2023]
Abstract
Background The long-term prognosis of patients with repaired aortic coarctation is characterized by high rates of cardiovascular and cerebrovascular disease related to hypertension, the basis of which remains unclear. To define potential underlying mechanisms, we investigated aortic and carotid arterial biomechanics and wave dynamics, and determinants of aortic systolic blood pressure, in young adults after coarctation repair. Methods and Results Aortic arch and carotid biomechanics, wave intensity and wave power, and central aortic blood pressure, were derived from echocardiography and brachial blood pressure in 43 young adults after coarctation repair and 42 controls. Coarctation subjects had higher brachial and central systolic blood pressure ( P=0.04), while aortic compliance was lower and characteristic impedance (Zc) higher. Although carotid intima-media thickness was higher ( P<0.001), carotid biomechanics were no different. Carotid forward compression wave power was higher and was negatively correlated with aortic compliance ( R2=0.42, P<0.001) and distensibility ( R2=0.37, P=0.001) in coarctation subjects. Aortic wave power and wave reflection indices were no different in control and coarctation patients, but coarctation patients with elevated aortic Zc had greater aorto-carotid transmission of forward compression wave power ( P=0.006). Aortic distensibility was the only independent predictor of central aortic systolic blood pressure on multivariable analysis. Conclusions Young adults following coarctation repair had a less compliant aorta, but no change in carotid biomechanics. Reduced aortic distensibility was related to greater transmission of aortic forward wave energy into the carotid artery and higher central aortic systolic blood pressure. These findings suggest that reduced aortic distensibility may contribute to later cardiovascular and cerebrovascular disease after coarctation repair.
Collapse
|
27
|
Marlevi D, Ruijsink B, Balmus M, Dillon-Murphy D, Fovargue D, Pushparajah K, Bertoglio C, Colarieti-Tosti M, Larsson M, Lamata P, Figueroa CA, Razavi R, Nordsletten DA. Estimation of Cardiovascular Relative Pressure Using Virtual Work-Energy. Sci Rep 2019; 9:1375. [PMID: 30718699 PMCID: PMC6362021 DOI: 10.1038/s41598-018-37714-0] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2018] [Accepted: 12/12/2018] [Indexed: 12/21/2022] Open
Abstract
Many cardiovascular diseases lead to local increases in relative pressure, reflecting the higher costs of driving blood flow. The utility of this biomarker for stratifying the severity of disease has thus driven the development of methods to measure these relative pressures. While intravascular catheterisation remains the most direct measure, its invasiveness limits clinical application in many instances. Non-invasive Doppler ultrasound estimates have partially addressed this gap; however only provide relative pressure estimates for a range of constricted cardiovascular conditions. Here we introduce a non-invasive method that enables arbitrary interrogation of relative pressures throughout an imaged vascular structure, leveraging modern phase contrast magnetic resonance imaging, the virtual work-energy equations, and a virtual field to provide robust and accurate estimates. The versatility and accuracy of the method is verified in a set of complex patient-specific cardiovascular models, where relative pressures into previously inaccessible flow regions are assessed. The method is further validated within a cohort of congenital heart disease patients, providing a novel tool for probing relative pressures in-vivo.
Collapse
|
28
|
Dijkema EJ, Slieker MG, Leiner T, Grotenhuis HB. Arterioventricular interaction after coarctation repair. Am Heart J 2018; 201:49-53. [PMID: 29910055 DOI: 10.1016/j.ahj.2018.04.004] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/06/2018] [Accepted: 04/02/2018] [Indexed: 12/25/2022]
Abstract
BACKGROUND Hypertension is common in patients with coarctation of the aorta (CoA), even after successful repair. Increased aortic stiffness has been implicated in the pathology of CoA-associated hypertension. This study aimed to investigate aortic vascular function and its relationship with hypertension in well-repaired CoA-patients at long-term follow-up. Furthermore, we assessed the additive effect of hypertension to adverse arterioventricular coupling associated with increased aortic stiffness. METHODS Twenty-two CoA-patients (age 30 ± 10.6 years) with successful surgical repair (n = 12) or balloon angioplasty (BA) (n = 10) between 3 months and 16 years of age with a follow-up of >10 years and 22 healthy controls underwent cardiac magnetic resonance imaging (CMR), at mean follow-up of 29.3 years, to study aortic pulse wave velocity (PWV), aortic distensibility, global left ventricular (LV) function, LV dimensions, and LV myocardial deformation. RESULTS CoA-patients had significantly increased aortic arch PWV (5.6 ± 1.9 m/s vs. 4.5 ± 1.0 m/s, P = .02) and decreased distensibility (4.5 ± 1.8 × 10-3 mmHg-1 vs. 5.8 ± 1.8 × 10-3 mmHg-1, P = .04) compared to controls. Significant differences in aortic arch PWV were found between hypertensive patients, normotensive patients and controls (6.1 ± 1.8 m/s vs. 4.9 ± 1.9 m/s and 4.5 ± 1.0 m/s, respectively, P = .03). Aortic arch PWV and distensibility were correlated with systolic blood pressure (R = 0.37 and R = -0.37, respectively, P = .03 for both). Global LV function, LV mass, LV dimensions and myocardial deformation were similar in CoA-patients when compared to controls. CONCLUSIONS Central aortic stiffness is significantly increased in well-repaired CoA-patients long-term after repair, and is associated with hypertension. Global LV function, myocardial deformation indices and LV dimensions are however preserved.
Collapse
|
29
|
Fernandes JF, Alves R, Ferreira da Silva T, Nordmeyer S, Hellmeier F, Goubergrits L, Hennemuth A, Berger F, Schubert S, Kuehne T, Kelm M. CMR-Based and Time-Shift Corrected Pressure Gradients Provide Good Agreement to Invasive Measurements in Aortic Coarctation. JACC Cardiovasc Imaging 2018; 11:1725-1727. [PMID: 29778860 DOI: 10.1016/j.jcmg.2018.03.013] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/05/2017] [Revised: 03/20/2018] [Accepted: 03/21/2018] [Indexed: 11/30/2022]
|
30
|
Foulds HJA, Giacomantonio NB, Bredin SSD, Warburton DER. A systematic review and meta-analysis of exercise and exercise hypertension in patients with aortic coarctation. J Hum Hypertens 2017; 31:768-775. [PMID: 28770819 DOI: 10.1038/jhh.2017.55] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2016] [Revised: 05/11/2017] [Accepted: 06/14/2017] [Indexed: 11/09/2022]
Abstract
Exercise hypertension is a common occurrence among individuals with aortic coarctation. Although exercise is known to be beneficial among the general population, the risks and benefits of exercise among those with aortic coarctation are less clear. This systematic review evaluates the benefits and risks of exercise for persons with aortic coarctation. Electronic databases were systematically searched (that is, MEDLINE and EMBASE) and key reviews cross-referenced to identify articles for inclusion. Original research articles reporting exercise among individuals with aortic coarctation were included. From 2608 individual citations, 68 eligible articles were identified. Aerobic exercise stress tests were found to be useful for determining exercise hypertension experiences post-surgical repair (N=5), and other long-term secondary findings (N=3). Experiences of exercise hypertension were associated with abnormal cardiac and/or aortic geometry and cardiac function (N=7). Exercise capacity was generally found to be similar to non-aortic coarctation controls post surgery (N=6). Exercise hypertension was experienced by 27% of participants, including 10% of adults and 43% of children/youth. Individuals who experience exercise hypertension experience greater increases in systolic blood pressure with exercise. No investigations identified evaluated forms of exercise other than aerobic stress tests and no exercise training programs have been conducted to date. Exercise stress tests can be valuable in this population for determining exercise hypertension, especially in the year post-surgical repair. Additional research is urgently needed to accurately assess the benefits and risks of exercise and exercise hypertension, and applicability of exercise restrictions for this population.
Collapse
|
31
|
Gounley J, Chaudhury R, Vardhan M, Driscoll M, Pathangey G, Winarta K, Ryan J, Frakes D, Randles A. Does the degree of coarctation of the aorta influence wall shear stress focal heterogeneity? ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2017; 2016:3429-3432. [PMID: 28269039 DOI: 10.1109/embc.2016.7591465] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
The development of atherosclerosis in the aorta is associated with low and oscillatory wall shear stress for normal patients. Moreover, localized differences in wall shear stress heterogeneity have been correlated with the presence of complex plaques in the descending aorta. While it is known that coarctation of the aorta can influence indices of wall shear stress, it is unclear how the degree of narrowing influences resulting patterns. We hypothesized that the degree of coarctation would have a strong influence on focal heterogeneity of wall shear stress. To test this hypothesis, we modeled the fluid dynamics in a patient-specific aorta with varied degrees of coarctation. We first validated a massively parallel computational model against experimental results for the patient geometry and then evaluated local shear stress patterns for a range of degrees of coarctation. Wall shear stress patterns at two cross sectional slices prone to develop atherosclerotic plaques were evaluated. Levels at different focal regions were compared to the conventional measure of average circumferential shear stress to enable localized quantification of coarctation-induced shear stress alteration. We find that the coarctation degree causes highly heterogeneous changes in wall shear stress.
Collapse
|
32
|
Mizutani Y, Tada N, Masuda T, Hata M. Simultaneous Transcatheter Intervention for Coarctation of the Aorta and Bicuspid Aortic Valve. THE JOURNAL OF HEART VALVE DISEASE 2017; 26:481-484. [PMID: 29302949] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
Coarctation of the aorta (CoA) is a relatively common congenital heart anomaly, and bicuspid aortic valve (BAV) is a common congenital heart disease that coexists with CoA. In larger children and adults with CoA, transcatheter intervention has gained acceptance, but for surgical high-risk patients with aortic stenosis, the use of transcatheter aortic valve implantation (TAVI) has been established. Recently, although favorable data have been reported for TAVI when treating BAV, simultaneous transcatheter intervention for CoA and BAV will prove to be a challenge because of the unique anatomy involved requires multiple procedural steps and also has problems of site access. Herein is reported a successful case of simultaneous thoracic endovascular repair (TEVAR) for CoA and transfemoral TAVI for congenital BAV dysfunction. A 62-year-old male with CoA and congenital BAV with severe aortic stenosis and aortic regurgitation had NYHA class IV heart failure symptoms. Because of the patient's extremely poor left ventricular function, the authors' heart team decided to perform simultaneous TEVAR for CoA and transfemoral TAVI. After deployment of a 32 mm stent graft, a 29 mm SAPIEN 3 valve (Edwards Lifesciences, Irvine, CA, USA) was successfully deployed through the stent graft. This resulted in no significant pressure gradient within the aorta, and no aortic regurgitation. Video 1: Cineradiography showing delivery of the Edwards Commander delivery system through the stent graft. Video 2: Final aortography showing no residual aortic regurgitation.
Collapse
|
33
|
Lee MGY, Hemmes RA, Mynard J, Lambert E, Head GA, Cheung MMH, Konstantinov IE, Brizard CP, Lambert G, d'Udekem Y. Elevated sympathetic activity, endothelial dysfunction, and late hypertension after repair of coarctation of the aorta. Int J Cardiol 2017; 243:185-190. [PMID: 28545853 DOI: 10.1016/j.ijcard.2017.05.075] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/16/2017] [Revised: 04/16/2017] [Accepted: 05/17/2017] [Indexed: 11/30/2022]
Abstract
BACKGROUND There is a high prevalence of late hypertension after coarctation repair. The relative contribution of elevated sympathetic tone and endothelial dysfunction to its development is unknown. This study aims to investigate the neural profile of coarctation patients including muscle sympathetic nerve activity testing to directly measure sympathetic nervous activity. METHODS Twenty-three patients aged ≥18years with a coarctation repair underwent measurements of clinic and 24-h blood pressures, muscle sympathetic nerve activity, sympathetic and cardiac baroreflex functions, digital endothelial function, and ambulatory arterial stiffness index. Median age at repair was 1.2months (interquartile range: 0-9months). Patients were compared to 17 healthy matched controls. RESULTS After 26±5years, 6% (1/18) and 44% (8/18) suffered clinic hypertension and prehypertension, respectively. On 24-h blood pressure monitoring, 15% (3/20) and 20% (4/20) had hypertension and prehypertension, respectively. Coarctation patients had elevated muscle sympathetic nerve activity compared with controls (49.6±24.9 vs. 29.9±14.0 bursts/100 heartbeats, p=0.02), dampened sympathetic baroreflex function (-2.2±2.1 vs. -7.0±5.6 bursts/100heartbeats·mm·Hg-1, p=0.007), normal cardiac baroreflex function (41.9±30.4 vs. 35.7±21.1ms·mm·Hg-1, p=0.6), endothelial dysfunction (pulse amplitude tonometry ratio: 0.39±0.32 vs. 0.81±0.50, p=0.004), and increased ambulatory arterial stiffness index (0.46±0.15 vs. 0.29±0.17, p=0.008). CONCLUSION After coarctation repair patients have increased muscle sympathetic nerve activity, dampened sympathetic baroreflex response, endothelial dysfunction, and increased ambulatory arterial stiffness index, all of which may contribute to the development of late hypertension.
Collapse
|
34
|
Rahman MN, Gul I, Nabi A. A Multiparous Woman with Lately Diagnosed Multilevel Left Ventricular Obstruction. J Coll Physicians Surg Pak 2017; 27:305-307. [PMID: 28599694] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2015] [Accepted: 01/21/2017] [Indexed: 06/07/2023]
Abstract
A 56-year hypertensive, multiparous woman presented to the cardiology unit with Canadian Cardiovascular Society (CCS) class-III angina and worsening dyspnea for the past few weeks. Her clinical examination showed high blood pressure and mid-systolic crescendo-decrescendo murmur radiating to carotids. However, there was no radio-femoral delay or significant blood pressure difference between her arms. Her transthoracic echocardiography (TTE) revealed moderate aortic stenosis (AS) and mid cavity left ventricular outflow (LVO) obstruction. Left heart catheterization (LHC) showed coarctation of aorta with extensive collaterals, mid cavity LVO obstruction, and moderate AS. Thus, she was diagnosed as a case of multi-level LVO obstruction including mid cavity LVO obstruction AS and coarctation of aorta. She underwent stenting of aortic coarctation as the initial step of graded approach to her disease, and is doing well.
Collapse
|
35
|
Wagner JB, Knowlton JQ, Pastuszko P, Shah SS. A Rare Case of Vascular Ring and Coarctation of the Aorta in Association with CHARGE Syndrome. Tex Heart Inst J 2017; 44:138-140. [PMID: 28461801 DOI: 10.14503/thij-16-5819] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
A male neonate presented with CHARGE syndrome, a multiorgan genetic disorder involving the Coloboma of the eyes, congenital Heart defects, nasal choanal Atresia, growth and development Retardation, Genitourinary disorders, and Ear anomalies and deafness. Moreover, he had a rare case of vascular ring-consisting of a right aortic arch with retroesophageal brachiocephalic artery-combined with coarctation of the mid-aortic arch. He underwent both vascular ring and aortic arch repair at our institution. To our knowledge, this is the 4th documented case of this exceedingly rare type of aortic arch anomaly combined with aortic arch obstruction. Moreover, it is the first confirmed case of these combined disorders occurring in CHARGE syndrome. This report describes a truly rare case and reveals the limitations of echocardiography in detecting complex aortic arch anomalies while illustrating the benefits of advanced imaging prior to surgical intervention.
Collapse
|
36
|
van Engelen A, Silva Vieira M, Rafiq I, Cecelja M, Schneider T, de Bliek H, Figueroa CA, Hussain T, Botnar RM, Alastruey J. Aortic length measurements for pulse wave velocity calculation: manual 2D vs automated 3D centreline extraction. J Cardiovasc Magn Reson 2017; 19:32. [PMID: 28270208 PMCID: PMC5341448 DOI: 10.1186/s12968-017-0341-y] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2016] [Accepted: 02/16/2017] [Indexed: 01/13/2023] Open
Abstract
BACKGROUND Pulse wave velocity (PWV) is a biomarker for the intrinsic stiffness of the aortic wall, and has been shown to be predictive for cardiovascular events. It can be assessed using cardiovascular magnetic resonance (CMR) from the delay between phase-contrast flow waveforms at two or more locations in the aorta, and the distance on CMR images between those locations. This study aimed to investigate the impact of different distance measurement methods on PWV. We present and evaluate an algorithm for automated centreline tracking in 3D images, and compare PWV calculations using distances derived from 3D images to those obtained from a conventional 2D oblique-sagittal image of the aorta. METHODS We included 35 patients from a twin cohort, and 20 post-coarctation repair patients. Phase-contrast flow was acquired in the ascending, descending and diaphragmatic aorta. A 3D centreline tracking algorithm is presented and evaluated on a subset of 30 subjects, on three CMR sequences: balanced steady-state free precession (SSFP), black-blood double inversion recovery turbo spin echo, and contrast-enhanced CMR angiography. Aortic lengths are subsequently compared between measurements from a 2D oblique-sagittal plane, and a 3D geometry. RESULTS The error in length of automated 3D centreline tracking compared with manual annotations ranged from 2.4 [1.8-4.3] mm (mean [IQR], black-blood) to 6.4 [4.7-8.9] mm (SSFP). The impact on PWV was below 0.5m/s (<5%). Differences between 2D and 3D centreline length were significant for the majority of our experiments (p < 0.05). Individual differences in PWV were larger than 0.5m/s in 15% of all cases (thoracic aorta) and 37% when studying the aortic arch only. Finally, the difference between end-diastolic and end-systolic 2D centreline lengths was statistically significant (p < 0.01), but resulted in small differences in PWV (0.08 [0.04 - 0.10]m/s). CONCLUSIONS Automatic aortic centreline tracking in three commonly used CMR sequences is possible with good accuracy. The 3D length obtained from such sequences can differ considerably from lengths obtained from a 2D oblique-sagittal plane, depending on aortic curvature, adequate planning of the oblique-sagittal plane, and patient motion between acquisitions. For accurate PWV measurements we recommend using 3D centrelines.
Collapse
|
37
|
Carlisle AJ, Shah AD, Appel D, Kogon BE. Unusual Repair of Aortic Coarctation: Transcatheter Intervention Implications. THE JOURNAL OF INVASIVE CARDIOLOGY 2017; 29:E41-E42. [PMID: 28255109] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
A 56-year old male was evaluated for exertional dyspnea. He had previously undergone mechanical aortic valve replacement and aortic coarctation repair. Following uncomplicated coronary angiography using Judkins left and right catheters, aortography revealed that the loud murmur was related to an unusual, extra-anatomic surgical repair: transverse aorta to descending aorta bypass. Recognition of an extra-anatomic surgical bypass of coarctation is important, as this repair would leave a continuous murmur on exam.
Collapse
|
38
|
Charchyan ER, Belov YV, Skvortsov AA, Salagaev GI. [Simultaneous Bentall-de-Bono procedure and descending thoracic aortic bypass through median sternotomy]. Khirurgiia (Mosk) 2017:69-71. [PMID: 29186100 DOI: 10.17116/hirurgia20171169-71] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
|
39
|
Voges I, Kees J, Jerosch-Herold M, Gottschalk H, Trentmann J, Hart C, Gabbert DD, Pardun E, Pham M, Andrade AC, Wegner P, Kristo I, Jansen O, Kramer HH, Rickers C. Aortic stiffening and its impact on left atrial volumes and function in patients after successful coarctation repair: a multiparametric cardiovascular magnetic resonance study. J Cardiovasc Magn Reson 2016; 18:56. [PMID: 27618813 PMCID: PMC5020476 DOI: 10.1186/s12968-016-0278-6] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2016] [Accepted: 08/26/2016] [Indexed: 01/08/2023] Open
Abstract
BACKGROUND The increased cardiovascular morbidity of adults with late repair of aortic coarctation (CoA) has been well documented. In contrast, successful CoA repair in early childhood has a generally good prognosis, though adverse vascular and ventricular characteristics may be abnormal, which could increase long-term risk. This study sought to perform a comprehensive analysis of aortic elasticity and left ventricular (LV) function in patients with aortic coarctation (CoA) using cardiovascular magnetic resonance (CMR). In a subgroup of patients, we assessed structure and function of the common carotid arteries to probe for signs of systemic vascular remodeling. METHODS Fifty-one patients (median age 17.3 years), 13.9 ± 7.5 years after CoA repair, and 54 controls (median age 19.8 years) underwent CMR. We determined distensibility and pulse wave velocity (PWV) at different aortic locations. In a subgroup, common carotid artery distensibility, PWV, wall thickness and wall area were measured. LV ejection fraction (EF), volumes, and mass were measured from short axis views. Left atrial (LA) volumes and functional parameters (LAEFPassive, LAEFContractile, LAEFReservoir) were assessed from axial cine images. RESULTS In patients distensibility of the whole thoracic aorta was reduced (p < 0.05) while PWV was only significantly higher in the aortic arch (p < 0.01). Distensibility of the descending aorta at the level of the pulmonary arteries and PWV in the descending aorta, both correlated negatively with age at CoA repair. LA volume before atrial contraction and minimal LA volume were higher in patients (p < 0.05). LAEFPassive and LAEFReservoir were reduced (p < 0.05), and LAEFReservoir correlated negatively with aortic arch PWV (p < 0.05). LVEF, volumes and mass were not different from controls. Carotid wall thickness and PWV were higher in patients compared to controls (p < 0.05). CONCLUSIONS Patients after CoA repair have impaired bioelastic properties of the thoracic aorta with impact on LV diastolic function. Reduced descending aortic elasticity is associated with older age at time of CoA repair. The remodeling of the common carotid artery in our sub-study suggests systemic vessel wall changes.
Collapse
|
40
|
Wendell DC, Samyn MM, Cava JR, Krolikowski MM, LaDisa JF. The Impact of Cardiac Motion on Aortic Valve Flow Used in Computational Simulations of the Thoracic Aorta. J Biomech Eng 2016; 138:2531718. [PMID: 27367143 DOI: 10.1115/1.4033964] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2015] [Indexed: 02/04/2023]
Abstract
Advancements in image-based computational modeling are producing increasingly more realistic representations of vasculature and hemodynamics, but so far have not compensated for cardiac motion when imposing inflow boundary conditions. The effect of cardiac motion on aortic flow is important when assessing sequelae in this region including coarctation of the aorta (CoA) or regurgitant fraction. The objective of this investigation was to develop a method to assess and correct for the influence of cardiac motion on blood flow measurements through the aortic valve (AoV) and to determine its impact on patient-specific local hemodynamics quantified by computational fluid dynamics (CFD). A motion-compensated inflow waveform was imposed into the CFD model of a patient with repaired CoA that accounted for the distance traveled by the basal plane during the cardiac cycle. Time-averaged wall shear stress (TAWSS) and turbulent kinetic energy (TKE) values were compared with CFD results of the same patient using the original waveform. Cardiac motion resulted in underestimation of flow during systole and overestimation during diastole. Influences of inflow waveforms on TAWSS were greatest along the outer wall of the ascending aorta (AscAo) (∼30 dyn/cm2). Differences in TAWSS were more pronounced than those from the model creation or mesh dependence aspects of CFD. TKE was slightly higher for the motion-compensated waveform throughout the aortic arch. These results suggest that accounting for cardiac motion when quantifying blood flow through the AoV can lead to different conclusions for hemodynamic indices, which may be important if these results are ultimately used to predict patient outcomes.
Collapse
|
41
|
Shikata F, Okamura T, Higaki T, Okura M, Kojima A, Uchita S, Izutani H. Aortic Coarctation 28 Days after an Arterial Switch Operation in a Neonate. Tex Heart Inst J 2016; 43:354-6. [PMID: 27547151 DOI: 10.14503/thij-15-5380] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
Aortic coarctation rarely occurs after an arterial switch operation for D-transposition of the great arteries with intact ventricular septum. We report the case of a neonate patient in whom aortic coarctation developed 28 days after an uncomplicated arterial switch operation. Preoperatively, the aorta was noted to have an irregular shape, but there was no pressure gradient across the lesion. The patient underwent successful reoperation to correct the coarctation. We hope that our report raises awareness of a rare early complication after arterial switch operation with intact ventricular septum, and the need to carefully monitor the aortic isthmus in patients who have aortic irregularities, even in the absence of a pressure gradient.
Collapse
|
42
|
Mivelaz Y, Leung MT, Zadorsky MT, De Souza AM, Potts JE, Sandor GGS. Noninvasive Assessment of Vascular Function in Postoperative Cardiovascular Disease (Coarctation of the Aorta, Tetralogy of Fallot, and Transposition of the Great Arteries). Am J Cardiol 2016; 118:597-602. [PMID: 27401272 DOI: 10.1016/j.amjcard.2016.05.055] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/29/2016] [Revised: 05/23/2016] [Accepted: 05/23/2016] [Indexed: 11/19/2022]
Abstract
Using noninvasive techniques, we sought to assess arterial stiffness, impedance, hydraulic power, and efficiency in children with postoperative tetralogy of Fallot (TOF), coarctation of the aorta (COA), and transposition of the great arteries (TGAs). Results were compared with those of healthy peers. Fifty-five children with repaired congenital heart disease (24 TOFs, 20 COAs, and 11 TGAs) were compared with 55 age-matched control subjects (CTRL). Echocardiographic Doppler imaging and carotid artery applanation tonometry were preformed to measure aortic flow, dimensions, and calculate pulse wave velocity, vascular impedance and arterial stiffness indexes, hydraulic power (mean and total), and hydraulic efficiency (HE) which were calculated using standard fluid dynamics equations. All congenital heart disease subgroups had higher pulse wave velocity than CTRL. Only the COA group had higher characteristic impedance. Mean power was higher in TGA than in CTRL and TOF, and total power was higher in TGA than in CTRL and TOF. Hydraulic efficiency was higher in TOF than in COA and TGA. In conclusion, children with TOF, COA, and TGA have stiffer aortas than CTRL. These changes may be related to intrinsic aortic abnormalities, altered integrity of the aorta due to surgical repair, and/or acquired postsurgery. These patients may be at increased long-term cardiovascular risk, and long-term follow-up is important for monitoring and assessment of efforts to reduce risk.
Collapse
|
43
|
Suárez de Lezo J, Romero M, Pan M, Suárez de Lezo J, Segura J, Ojeda S, Pavlovic D, Mazuelos F, López Aguilera J, Espejo Perez S. Stent Repair for Complex Coarctation of Aorta. JACC Cardiovasc Interv 2016; 8:1368-1379. [PMID: 26315741 DOI: 10.1016/j.jcin.2015.05.018] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/11/2015] [Revised: 04/13/2015] [Accepted: 05/07/2015] [Indexed: 11/19/2022]
Abstract
OBJECTIVES This study sought to determine whether several anatomic or evolving characteristics of the coarctation may create challenging conditions for treatment. BACKGROUND Stent repair of coarctation of aorta is an alternative to surgical correction. METHODS We analyzed our 21-year experience in the percutaneous treatment of complex coarctation of aorta. Adverse conditions for treatment were as follow: 1) complete interruption of the aortic arch (n = 11); 2) associated aneurysm (n = 18); 3) complex stenosis (n = 30); and 4) the need for re-expansion and/or restenting (n = 21). Twenty patients (33%) belonged to more than 1 group. Ten interruptions were type A and 1 was type B. The mean length of the interrupted aorta was 9 ± 11 mm. The associated aneurysms were native in 8 patients and after previous intervention in 10 patients. Aneurysm shapes were fusiform in 8 patients and saccular in 10. The following characteristics defined complex stenosis as long diffuse stenosis, very tortuous coarctation, or stenosis involving a main branch or an unusual location. Patients previously stented at an early age, required re-expansion and/or restenting after reaching 16 ± 5 years of age. RESULTS Two patients had died by 1-month follow-up. The remaining 58 patients did well and were followed-up for a mean period of 10 ± 6 years. Late adverse events occurred in 3 patients (5%). All remaining patients are symptom-free, with normal baseline blood pressure. Imaging techniques revealed good patency at follow-up without associated aneurysm or restenosis. The actuarial survival free probability of all complex patients at 15 years was 92%. CONCLUSIONS Stent repair of complex coarctation of aorta is feasible and safe. Initial results are maintained at later follow-up.
Collapse
|
44
|
Bruse JL, McLeod K, Biglino G, Ntsinjana HN, Capelli C, Hsia TY, Sermesant M, Pennec X, Taylor AM, Schievano S. A statistical shape modelling framework to extract 3D shape biomarkers from medical imaging data: assessing arch morphology of repaired coarctation of the aorta. BMC Med Imaging 2016; 16:40. [PMID: 27245048 PMCID: PMC4894556 DOI: 10.1186/s12880-016-0142-z] [Citation(s) in RCA: 51] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2015] [Accepted: 05/19/2016] [Indexed: 11/29/2022] Open
Abstract
BACKGROUND Medical image analysis in clinical practice is commonly carried out on 2D image data, without fully exploiting the detailed 3D anatomical information that is provided by modern non-invasive medical imaging techniques. In this paper, a statistical shape analysis method is presented, which enables the extraction of 3D anatomical shape features from cardiovascular magnetic resonance (CMR) image data, with no need for manual landmarking. The method was applied to repaired aortic coarctation arches that present complex shapes, with the aim of capturing shape features as biomarkers of potential functional relevance. The method is presented from the user-perspective and is evaluated by comparing results with traditional morphometric measurements. METHODS Steps required to set up the statistical shape modelling analyses, from pre-processing of the CMR images to parameter setting and strategies to account for size differences and outliers, are described in detail. The anatomical mean shape of 20 aortic arches post-aortic coarctation repair (CoA) was computed based on surface models reconstructed from CMR data. By analysing transformations that deform the mean shape towards each of the individual patient's anatomy, shape patterns related to differences in body surface area (BSA) and ejection fraction (EF) were extracted. The resulting shape vectors, describing shape features in 3D, were compared with traditionally measured 2D and 3D morphometric parameters. RESULTS The computed 3D mean shape was close to population mean values of geometric shape descriptors and visually integrated characteristic shape features associated with our population of CoA shapes. After removing size effects due to differences in body surface area (BSA) between patients, distinct 3D shape features of the aortic arch correlated significantly with EF (r = 0.521, p = .022) and were well in agreement with trends as shown by traditional shape descriptors. CONCLUSIONS The suggested method has the potential to discover previously unknown 3D shape biomarkers from medical imaging data. Thus, it could contribute to improving diagnosis and risk stratification in complex cardiac disease.
Collapse
|
45
|
Zhang HY. Upper-to-lower-limb Collateral Circulation in a Patient with Aortic Coarctation. Eur J Vasc Endovasc Surg 2016; 51:749. [PMID: 27010661 DOI: 10.1016/j.ejvs.2016.02.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2016] [Accepted: 02/13/2016] [Indexed: 11/16/2022]
|
46
|
Phillips AR, Eliason JL, Stanley JC, Coleman DM. Infantile Renovascular Hypertension with Failure to Thrive. Ann Vasc Surg 2016; 33:227.e5-8. [PMID: 26965798 DOI: 10.1016/j.avsg.2015.12.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2015] [Revised: 10/08/2015] [Accepted: 12/02/2015] [Indexed: 11/18/2022]
Abstract
Severe hypertension in infancy is a rare cause of failure to thrive. The successful surgical management of this disease in an infant having refractory renovascular hypertension and growth failure is reported.
Collapse
|
47
|
Kowalik E, Kowalski M, Klisiewicz A, Hoffman P. Global area strain is a sensitive marker of subendocardial damage in adults after optimal repair of aortic coarctation: three-dimensional speckle-tracking echocardiography data. Heart Vessels 2016; 31:1790-1797. [PMID: 26843196 PMCID: PMC5085995 DOI: 10.1007/s00380-016-0803-4] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/07/2015] [Accepted: 01/22/2016] [Indexed: 01/20/2023]
Abstract
Aortic coarctation (CoA) in adults is associated with reduced survival. Despite successful repair, some unfavorable changes in the left ventricular (LV) myocardial function are reported. Three-dimensional speckle-tracking imaging (3D-STE) is a novel method that allows to assess regional myocardial function in all directions simultaneously and to calculate global area strain which integrates longitudinal and circumferential deformation. The aim of our study was to assess whether 3-D STE provides any new characteristics of LV deformation in patients with optimal CoA repair. Adults after CoA correction underwent transthoracic echocardiographic examinations. Patients with significant concomitant lesions were ruled out. Global longitudinal strain (GLS), global circumferential strain (GCS), global area strain (GAS), and global radial strain (GRS) were assessed using 3D-STE (Echopac Software, GE). The data were compared with those obtained from healthy subjects. 26 adults (9F/17M; mean age 24.4 years) with repaired CoA were studied. Despite preserved LVEFs, patients with repaired CoA had decreased GAS compared with controls (−28.8 vs. −31.7 %; p = 0.007). No differences between patients and healthy subjects in terms of GLS, GCS and GRS were observed. We found a significant correlation between mean blood pressure and GAS (R = 0.39; p < 0.05). No significant influence of age at repair, CoA correction method or LV mass on three-dimensional deformation was observed. Summarizing, global area strain derived from 3D-STE may be a sensitive indicator of subclinical LV dysfunction in patients after optimal repair of CoA. Mean blood pressure, but not age at correction seems to determine LV deformation.
Collapse
|
48
|
Perry PA, Young N. Aortic Root Enlargement with Ascending-to-Descending Aortic Bypass in Repair of Coarctation. THE JOURNAL OF HEART VALVE DISEASE 2015; 24:516-518. [PMID: 26897826] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Ascending-to-descending aortic bypass is a valuable technique for addressing coarctation of the aorta when additional cardiac procedures are indicated in adults. Among these, aortic valve replacement is one of the most commonly performed concomitant procedures, and there are instances in which aortic root enlargement is required. Herein, a novel technique is described for performing simultaneous ascending-to-descending aortic bypass in conjunction with aortic root enlargement which incorporates the bypass graft as part of the aortic root enlargement.
Collapse
|
49
|
Kelminson LL. Coarctation of the aorta in infancy. Pathologic, physiologic, and clinical considerations. Adv Cardiol 2015; 11:43-7. [PMID: 4606351 DOI: 10.1159/000395203] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
|
50
|
Jashari H, Rydberg A, Ibrahimi P, Bajraktari G, Henein MY. Left ventricular response to pressure afterload in children: aortic stenosis and coarctation: a systematic review of the current evidence. Int J Cardiol 2015; 178:203-9. [PMID: 25464254 DOI: 10.1016/j.ijcard.2014.10.089] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/26/2014] [Revised: 10/10/2014] [Accepted: 10/18/2014] [Indexed: 02/05/2023]
Abstract
Congenital aortic stenosis (CAS) and Coarctation of Aorta (CoA) represent two forms of pressure afterload that affect the left ventricle (LV), hence require regular echocardiographic monitoring. Subclinical dysfunction of the LV exists even in asymptomatic patients with preserved left ventricular ejection fraction (EF), implying low sensitivity of EF in predicting optimum time for intervention. In this article we review patterns of LV myocardial deformation before and after correction of CAS and CoA in infants, children and adolescents, showing their important role in monitoring the course of LV dysfunction. A systematic search using PubMed was performed and suitable studies are presented on a narrative form. Normal EF and/or fractional shortening (FS), with subclinical myocardial dysfunction are reported in all studies before intervention. The short-term results, after intervention, were related to the type of procedure, with no improvement or further deterioration related to surgery but immediate improvement after balloon intervention. Long term follow-up showed further improvement but still subnormal function. Thus correction of CAS and CoA before irreversible LV dysfunction is vital, and requires longitudinal studies in order to identify the most accurate parameter for function prognostication. Until then, conventional echocardiographic parameters together with myocardial velocities and deformation parameters should continue to provide follow-up reproducible measures of ventricular function.
Collapse
|