26
|
Trajtenberg CP, Pereira PNR, Powers JM. Resin bond strength and micromorphology of human teeth prepared with an Erbium:YAG laser. AMERICAN JOURNAL OF DENTISTRY 2004; 17:331-6. [PMID: 15575443] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/01/2023]
Abstract
PURPOSE To evaluate the in vitro effect of the Er:YAG laser and high-speed rotary instrumentation on the bond strength of resin composite to human enamel and dentin, and determine which conditioner, either phosphoric acid or a self-etching primer, resulted in higher bond strengths with either of the surface treatments. METHODS 48 third molars were used. Dentin and enamel specimens were sectioned and polished with 600-grit SiC paper and treated either with carbide bur or an Erbium:YAG laser and treated with one of three different conditions, acid-etch/bonding agent (Scotchbond Multi-Purpose Plus), no etching and same bonding agent, and an experimental self-etching primer (EXL 547). After storage for 48 hours at 37 degrees C and 100% humidity, specimens were prepared in an hourglass shape for microtensile bond test (ca. 1 mm2) and debonded in tension. Areas were measured and bond strengths were calculated for each specimen. Failure modes, micromorphology of surface treatments and bonding interfaces of representative specimens from acid-etched and self-etched groups were analyzed with scanning electron microscopy. Means were compared using three-way analysis of variance, and Scheffé post-hoc test (P < 0.05) was used to determine differences among surface treatments, tooth substrate and conditioners. RESULTS Dentin prepared with the carbide bur and treated with phosphoric acid followed by the application of Scotchbond Multi-Purpose had the highest bond strengths (35.7 MPa). Enamel and dentin prepared with the Er:YAG laser had the highest bond strengths when the surfaces were acid-etched followed by Scotchbond Multi-Purpose (25.8-21.1 MPa). Carbide bur exhibited higher bond strengths than laser with the use of the experimental self-etching primer but laser showed higher bond strengths than the bur with the use of Scotchbond Multi-Purpose and no etching. The predominant failure mode of most of the treatment conditions was partially adhesive between the bonding resin and enamel or dentin, and partially cohesive within the bonding resin. SEM analysis revealed the absence of a smear layer on laser-treated teeth when compared to untreated control and bur-cut teeth.
Collapse
|
27
|
Chinelatti MA, Ramos RP, Chimello DT, Borsatto MC, Pécora JD, Palma-Dibb RG. Influence of the use of Er:YAG laser for cavity preparation and surface treatment in microleakage of resin-modified glass ionomer restorations. Oper Dent 2004; 29:430-6. [PMID: 15279483] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/30/2023]
Abstract
This study quantitatively assessed the amount of microleakage on Class V cavities prepared by Er:YAG laser and high-speed handpiece, varying the surface treatment and restoring with a resin-modified glass ionomer cement. Fifty cavities were prepared using either an Er:YAG laser device or a carbide bur at high speed. The surface treatment was performed as follows: Er:YAG laser irradiation (G1); 40% polyacrylic acid (G2); laser + acid (G3); finishing with low speed + laser + acid (G4); conventional bur preparation + acid (G5-control). The samples were restored with Fuji II LC, thermocycled, isolated and immersed in a 50% AgNO3 solution. The restorations were serially sectioned and the extent of dye penetration was measured in milimeters using specific computer software. Data were analyzed by two-way ANOVA and Tukey test. The lowest degree of microleakage was observed for G5, which was statistically similar (p>0.05) to G4 but different (p<0.05) from all the other experiental groups. Lesser microleakage was observed at the occlusal margins than at the cervical margins (p<0.05). It may be concluded that the use of Er:YAG laser for cavity preparation and surface treatment negatively affected the marginal sealing of resin-modified glass ionomer restorations.
Collapse
|
28
|
Campbell JH, Murray RA. Handpiece speed and postoperative outcomes in third molar surgery. JOURNAL (INDIANA DENTAL ASSOCIATION) 2004; 83:4-6. [PMID: 15266731] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 04/30/2023]
Abstract
OBJECTIVE This study was performed to assess surgical outcomes when externally irrigated slow-speed surgical handpieces (30,000 rpm) were compared to externally irrigated high-speed handpieces (90,000 rpm) in the removal of impacted lower third molar teeth. STUDY DESIGN One hundred patients with bilater ally impacted third molar s were enrolled in the study; 53 remained to completion. Each patient served as his/her own control. The experimental side was treated using a 30,000 rpm electric rotary drill incorporating irrigation, while the control side was treated using the same drill system, but with a 90,000 rpm handpiece. Drill speeds used were alternated between the right and left sides of patients to avoid bias introduced by the dominant hand of the surgeon. Patients were blinded to drill speed, and were asked to complete a standardized pain/swelling questionnaire for seven days immediately following surgery. Data was analyzed to determine differences in pain, swelling, and complications in relation to the drill type used. RESULTS No statistically significant differences were found in degree of pain, swelling, or complications when the slower drill was compared to the high-speed instrument. CONCLUSIONS The study suggests that there is no difference in postoperative outcome when impacted third molar teeth are removed with either slow- or high-speed instrumentation, and that the choice of the drill type should be determined solely by the preference of the operator.
Collapse
|
29
|
Kinoshita JI, Kimura Y, Matsumoto K. Comparative Study of Carious Dentin Removal by Er,Cr:YSGG Laser and Carisolv. ACTA ACUST UNITED AC 2003; 21:307-15. [PMID: 14651800 DOI: 10.1089/104454703322564532] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
OBJECTIVE The present study aimed to compare carious dentin removal by air turbine, Carisolv and erbium,chromium:yttrium,scandium,gallium,garnet (Er,Cr:YSGG) laser, and examine morphological changes before and after these caries removal techniques under light microscopy and scanning electron microscopy (SEM). BACKGROUND DATA Although there have been numerous studies on removing caries by Er,Cr:YSGG laser, none has compared Er,Cr:YSGG laser and Carisolv, or reported on the usage of DIAGNOdent as a diagnostic tool particularly for advanced caries in in vitro experiments. MATERIALS AND METHODS Sixty extracted human teeth diagnosed as advanced caries were divided into three groups based on the treatment received, namely air turbine, Carisolv, and Er,Cr:YSGG laser groups. Each group was sub-divided into two in order to examine the results with or without finishing using nylon brush, 15% ethylene diamine tetraacetic acid (EDTA) or low-power laser, respectively. After evaluation by DIAGNOdent, specimens were observed under light microscopy or SEM. RESULTS Light microscopic observations varied considerably in the three treatment groups. SEM revealed that the surfaces treated by air turbine were very smooth, but with substantial debris. The Carisolv group exhibited a very rough surface with a thick smear layer, while the Er,Cr:YSGG group demonstrated smooth undulations with little smear layer and debris. Among the finishing techniques, the laser group demonstrated the best efficiency. DIAGNOdent scores supported the results of light microscopy. CONCLUSION These results suggest that caries removal by Er,Cr:YSGG laser is very effective even without finishing and DIAGNOdent is useful for diagnosing advanced caries in in vitro experiments.
Collapse
|
30
|
Abstract
OBJECTIVES Scanning laser vibrometry is a noninvasive method of measuring the velocity, displacement amplitude and oscillation frequency of vibrating objects. The purpose of this study was to assess, using a scanning laser vibrometer (SLV), the performance of different designs of commercially available ultrasonic scaler generators by measuring the oscillatory characteristics of various scaler tips. METHODS Four ultrasonic generators were tested (Cavitron SPS and Cavitron Select (Dentsply, York, PA, USA) and Piezon Master 400 and Mini Piezon (Electro-Medical Systems, Switzerland)) with various designs of scaler tip. The tips were positioned with their anterior surface perpendicular to the direction of the laser. A graduated scale, placed over the manufacturer's power dial, enabled incremental power setting selection. For each power setting, the laser beam from the SLV was scanned over the surface of the oscillating tip. RESULTS The ranges of longitudinal displacement amplitudes (in micrometres) were as follows: Mini Piezon (P-tip): 12.90+/-1.44 to 44.03+/-7.80; Piezon Master 400 (P-tip): 16.02+/-2.66 to 35.85+/-5.29; Cavitron SPS (TFI-10 tip): 7.81+/-0.51 to 29.70+/-1.12; Cavitron Select (TFI-10 tip): 13.13+/-1.44 to 33.77+/-4.27; Cavitron SPS (TFI-3 tip): 5.50+/-0.46 to 31.35+/-3.62. CONCLUSIONS This study shows that there are differences between commercially available generators and that tip movement varies between tips of the same style as well as between the generator and tip design. Users of ultrasonic scalers should be made aware of this inherent variability that may influence clinical procedures.
Collapse
|
31
|
Petersilka GJ, Draenert M, Mehl A, Hickel R, Flemmig TF. Safety and efficiency of novel sonic scaler tips in vitro. J Clin Periodontol 2003; 30:551-5. [PMID: 12795794 DOI: 10.1034/j.1600-051x.2003.00300.x] [Citation(s) in RCA: 19] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
BACKGROUND The aim of the study was to evaluate a novel sonic scaler tip for subgingival root surface instrumentation combining high efficiency in calculus removal with minimized risk of root damage through subgingival debridement. METHODS A metal sonic scaler tip with a paddle-like working end covered with spheroid convexities of 0.8 mm diameter and 0.3 mm height was designed from the aspect of optimized adaptation to the root anatomy (tip-end dimension: 3.0 x 1.5 x 0.6 mm). Using a customary sonic scaler tip as control, instrument efficiency was quantified by measuring the time needed to completely remove calculus on extracted teeth (n=52) under standardized conditions. To quantify the amount of calculus removed, the mean calculus area per tooth was measured on photographs taken before instrumentation. The tips safety was evaluated instrumenting calculus-free root surfaces in vitro (n=18, lateral forces 0.5, 1, 2 N, 20 s instrumentation time, tip angulation 0 degrees ) with subsequent laser-optical determination of resulting root substance loss. RESULTS Debridement efficiency was significantly higher for the novel tip (0.78+/-0.81 mm2/s completely debrided) than for the conventional tip (0.42+/-0.33 mm2) (Mann-Whitney test, p<0.05). Concerning instrument safety, the novel tip caused significantly less root substance loss than the conventional tip. CONCLUSION The novel scaler tip appears to be significantly more efficient in calculus removal and less damaging to the root surface than the assessed conventional tip.
Collapse
|
32
|
Rossouw PE, Tortorella A. A pilot investigation of enamel reduction procedures. JOURNAL (CANADIAN DENTAL ASSOCIATION) 2003; 69:384-8. [PMID: 12787476] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 03/02/2023]
Abstract
OBJECTIVE To test and describe the use of various combinations of mechanical and chemical techniques for enamel reduction to obtain a smooth surface. METHODS Bovine teeth (2 surfaces on each of 32 teeth) were used. The teeth were mounted in blocks of dental plaster, which were then mounted in a vise. The mesiodistal enamel contact areas were reduced by various combinations of mechanical and chemical aids. The mesiodistal width of each tooth was measured with a digital caliper after initial reduction of the enamel surface and again after polishing. The teeth were subsequently prepared and mounted for scanning electron microscopy. RESULTS All combinations yielded statistically significant enamel reduction (p < 0.05). The use of acid stripping in conjunction with mechanical procedures produced especially smooth enamel surfaces. CONCLUSIONS Steps must be taken to ensure that a smooth enamel surface remains after enamel reduction and polishing. It is recommended that conventional enamel etchants be added to the polishing procedure. Enamel reduction can increase available space, but the quantity of enamel that can be removed without adverse consequences should be carefully evaluated.
Collapse
|
33
|
Hall DL. Methicillin-resistant Staphylococcus aureus and infection control for restorative dental treatment in nursing homes. SPECIAL CARE IN DENTISTRY 2003; 23:100-7. [PMID: 14650558 DOI: 10.1111/j.1754-4505.2003.tb01669.x] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
Abstract
The prevalence of methicillin-resistant Staphylococcus aureus (MRSA) in nursing home residents now averages 20-35%. This includes both numerous asymptomatic mostly unidentified carriers, and the occasional patient with an active infection. Among the most common sites for positive MRSA colonization are the nares and mouth (saliva). Ohio State University (OSU) dental students perform routine restorative dental care onsite in local nursing homes using portable equipment including handpieces that can generate aerosols. Using a series of cultured test swabs and plates, this pilot study suggests that protection for both dental health care personnel and patients are provided by the following: 1. universal barrier precautions (for example, gloves, gowns, masks, hats, facial shields, glasses), 2. surface disinfectants, 3. pre-op 0.12% chlorhexidene mouth rinses, 4. high volume evacuation, 5. perioral skin scrubs. Additional infection control methods, techniques and equipment were evaluated and compared including rubber dam isolation, hand excavation and bond technique, high-speed air turbine and electric "high" speed handpiece. There was no indication of a special tendency or heightened ability of MRSA to aerosolize.
Collapse
|
34
|
von Fraunhofer JA, Siegel SC. Using chemomechanically assisted diamond bur cutting for improved efficiency. J Am Dent Assoc 2003; 134:53-8; quiz 118. [PMID: 12555957 DOI: 10.14219/jada.archive.2003.0017] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
BACKGROUND Surface active agents added to handpiece coolants enhance bur cutting rates, or CRs, through chemomechanical effects, or CMEs. The authors evaluate the effect of CMEs on long-term cutting by diamond burs. METHODS The authors tested medium-grit diamonds in a high-speed handpiece under a 147.5-gram load at 350,000 revolutions per minute, with 22 milliliters per minute coolant flow consisting of distilled water or a 1:10 mouthwash/water mixture. Repeated 6-millimeter-long edge cuts were made through machinable glass ceramic bars until the CR (determined as the time to transect the bars) had decreased by more than 75 percent. The authors used six burs for each coolant and analyzed the data via one-way analysis of variance with post hoc Scheffé tests. RESULTS CRs with water irrigation continuously decreased with the number of cuts and declined by 87 percent over eight cuts. The authors found faster CRs with CMEs; after 12 cuts, the CR was still close to 40 percent of the initial CR, compared with only 13 percent of the initial CR for water irrigation after eight cuts. These differences between CME-enhanced CRs and those found with water irrigation were statistically significant. CONCLUSIONS Diluted alcohol- and glycerol-based mouthwash/water mixtures significantly enhanced the CRs of diamond burs and prolonged their service life by more than 50 percent compared with water irrigation alone. CLINICAL IMPLICATIONS Dentists can increase bur CRs and extend bur cutting life by as much as 200 percent through the addition of diluted alcohol and glycerol mouthwash to the handpiece coolant.
Collapse
|
35
|
Sharawy M, Misch CE, Weller N, Tehemar S. Heat generation during implant drilling: the significance of motor speed. J Oral Maxillofac Surg 2002; 60:1160-9. [PMID: 12378492 DOI: 10.1053/joms.2002.34992] [Citation(s) in RCA: 131] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
PURPOSE The purpose of this study was to measure the heat generated from 3 drilling speeds (1,225, 1,667, and 2,500 rpm) using the armamentarium of 4 implant systems. MATERIALS AND METHODS The mean rise in temperature, the time of drilling, and the time needed for pig jaw bone to return to the baseline temperature were monitored using 4 thermocouple technology. RESULTS The mean rise in temperature, the time of drilling, and the time needed for the specimens to return to the baseline temperature were lower at 2,500 rpm than at 1,667 or 1,225 rpm (P < or =.05), regardless of the system used. The rpm also directly correlated to the amount of time the bone remained at an elevated temperature. CONCLUSION From a heat generation standpoint, we conclude that preparing an implant site at 2500 rpm could decrease the risk of osseous damage, which may affect the initial healing of dental implants. This may decrease the devital zone adjacent to an implant after surgery and be most advantageous in immediate load application to dental implants.
Collapse
|
36
|
Segović S, Ferk S, Anić I, Jukić S, Galić N, Sistig S. Changes in dentin after insertion of self-threading titanium pins with 3 methods: a scanning electron microscope pilot study. J Prosthet Dent 2002; 87:182-8. [PMID: 11854675 DOI: 10.1067/mpr.2002.120652] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
STATEMENT OF PROBLEM Inserting a self-threading pin can cause dentinal cracks, but it is not known whether dentin bonding agents can penetrate these cracks. PURPOSE Part I of this in vitro pilot study was conducted to document the presence of dentinal cracks after the placement of self-threading pins with 3 methods. Part II was conducted to observe changes in dentin when a dentin bonding agent was applied before insertion of the self-threading pins. MATERIAL AND METHODS The crowns of 14 noncarious third molars were sectioned horizontally 2 mm above the cemento-enamel junction, and the occlusal portions were discarded. The teeth were put into a nontransparent bag and divided randomly into 2 groups. Group 1 consisted of 12 teeth. In each tooth, 4 pinholes were prepared with a handpiece at normal rotation speed (30,000 rpm). Self-threading pins were placed into 3 of the pinholes in each tooth: 1 manually, 1 by handpiece at 7000 rpm, and 1 by handpiece at 30,000 rpm. The fourth pinhole was left empty and served as the control. All group 1 teeth were sectioned vertically through the pins, dental hard tissue, and control pin holes. The examination surface of each specimen in group 1 was polished, and the smear layer was removed with Calcinase and NaOCl solutions. After dehydration in ascending grades of alcohol, specimens were coated with a 10- to 15-nm-thick layer of gold and examined with a scanning electron microscope. In the remaining 2 teeth (group 2), a dentin bonding agent was introduced into the pinholes prior to pin placement. Two pins were placed manually and 2 by handpiece at 30,000 rpm. After pin placement, sectioning, cleaning, and dehydration, the specimens were examined with a scanning electron microscope, and x-ray mapping was performed to determine the presence of titanium, silicon, and calcium. RESULTS Craze lines in dentin were associated with 54.5% of pins placed manually and 54.5% of pins placed with a handpiece at reduced speed (7000 rpm). Dentinal cracks were associated with 50% of pins placed with a handpiece at standard speed and with 16.7% of the control pinholes. X-ray mapping analysis revealed the presence of the dentin bonding agent between the pin and dentin wall. The dentin bonding agent was not found in the dentinal cracks except at the crack orifice. SUMMARY Within the limitations of this pilot study, the method of pin insertion had no direct bearing on the presence of dentinal cracks. The dentin bonding agent tested did not fill the entire space of dentinal cracks but did occlude their orifices and fill the spaces between pin surface and dentin walls in the pin preparation.
Collapse
|
37
|
Tygesen YA, Steiman HR, Ciavarro C. Comparison of distortion and separation utilizing profile and Pow-R nickel-titanium rotary files. J Endod 2001; 27:762-4. [PMID: 11771585 DOI: 10.1097/00004770-200112000-00012] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
The purpose of this study was to determine whether there was a difference in the frequency of file distortion and separation between nickel-titanium (Ni-Ti) ProFile 0.04 ISO taper rotary files and Ni-Ti Pow-R 0.04 ISO taper rotary files. For this study, 60 mesial root canals in 30 human mandibular first molars were chosen with the curvature angle of the mesiobuccal and mesiolingual canals of the same tooth within five degrees. ProFile and Pow-R files were randomly assigned to either the mesiobuccal or mesiolingual canal of the same tooth. Instrumentation proceeded per the manufacturer's recommendations, in a crown-down technique, using Gates Glidden burs and rotary files in sizes #50 to #20. Positive and negative controls were used. The instruments were evaluated for signs of distortion or separation by three independent evaluators using magnification under microscope. A total of 420 files were evaluated, 210 files for Pow-R and 210 files for ProFile. There was no statistically significant difference in the incidence of instrument distortion or separation between the two file systems that were studied.
Collapse
|
38
|
Gambarini G. Cyclic fatigue of nickel-titanium rotary instruments after clinical use with low- and high-torque endodontic motors. J Endod 2001; 27:772-4. [PMID: 11771588 DOI: 10.1097/00004770-200112000-00015] [Citation(s) in RCA: 108] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
This study investigated the cyclic fatigue resistance of used nickel-titanium rotary instruments, clinically operated by a traditional high-torque motor and a new low-torque electric motor. Fifty instruments (ProFile, Maillefer, Baillagues, Switzerland) for each of the following sizes were used: .06-25, .06-20, and .04-25. They were divided into three groups: A = 10 new instruments (control), B = 20 used instruments operated by a high-torque motor, and C = 20 used instruments operated by a low-torque motor. Each instrument was used in 10 clinical cases (at least six molars). Cyclic fatigue testing of new and used instruments was performed with a device that allowed the instruments to rotate freely inside a stainless-steel artificial canal at 350 rpm. Data were recorded and statistically analyzed. Mean (and SD) numbers of rotation-to-breakage cycles for .06-25, .06-20, and .04-25 instruments were, respectively: group A 463 (85), 535 (101), and 613 (105); group B 229 (64), 343 (92), and 233 (84); and group C 352 (77), 454 (89), and 466 (86). Results showed that group A instruments exhibited significantly higher values of rotation-to-breakage cycles (two-sample t test, p < 0.01), when compared with groups B and C, respectively. Statistically higher resistance to cyclic fatigue was noted for group C in all sizes compared with group B (two-sample t test, p < 0.01), showing that the use of endodontic motor with lower torque values reduced cyclic fatigue of nickel-titanium rotary instruments.
Collapse
|
39
|
Tripi TR, Bonaccorso A, Tripi V, Condorelli GG, Rapisarda E. Defects in GT rotary instruments after use: an SEM study. J Endod 2001; 27:782-5. [PMID: 11771591 DOI: 10.1097/00004770-200112000-00018] [Citation(s) in RCA: 38] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
Used rotary nickel-titanium instruments require frequent replacement. This laboratory study evaluated defects of GT Rotary instruments before and after usage. The instruments were fixed into custom-made holders and photographed in an SEM at x 260 to x 12,000 magnification at preset points. Instrument sizes 20 with 1.0, 0.8, and 0.6 taper and instrument sizes 35 with 1.2 taper were used in 12 canals. The used instruments were cleaned and then reexamined in an SEM as before. The presence of 11 types of conditions was scored from the pre- and postusage photographs. No instruments fracturing or plastic deformation was observed during the test. The presence of debris, pitting, and scraping changed significantly. Imperfections were found on used GT Rotary instruments and the presence of defects (pitting, scraping, and blunt-cutting edges) increased in all of the instruments. The behavior of GT Rotary instruments with usage seems to be different, compared with that found in other instruments.
Collapse
|
40
|
Harris BH, Kohles SS. Effects of mechanical and thermal fatigue on dental drill performance. Int J Oral Maxillofac Implants 2001; 16:819-26. [PMID: 11769832] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/23/2023] Open
Abstract
Osseous integration of dental implants depends on the use of proper surgical technique during site preparation, including the prevention of thermal injury to the surrounding bone. Heat generation during drilling has been reported to positively correlate with the production of forces at the surgical site. In this study, peak torque and axial load levels were measured during a drilling procedure into a polymeric material simulating the human mandible. Axial rotary milling was performed using 5 different twist drill designs (3i Irrigated Tri-Spade, 3i Disposable, Nobel-Biocare, Straumann, and Lifecore) of 15 to 20 mm in length and 2 to 2.3 mm in diameter, at a free-running rotational speed of 1,500 rpm and continuous feed rate of 3.5 mm/second, to a total depth of 10.5 mm. Ten drills representing each of the 5 types (n = 50) were subjected to 30 individual drill "pecks" and heat-sterilized every 3 "pecks" to determine the effects of cyclic mechanical and thermal loading on drill performance. Normal stress (sigma) and shear stress (tau) were calculated from the kinetic data and drill geometries. A drill efficiency coefficient (mu) was also calculated as the ratio of torsional resistance to translational resistance. Overall, the hypotheses of drill performance dependency on drill type as well as mechanical and thermal accumulated loading were tested and confirmed (P < .05). The 5 drill types produced a range of normal stresses (2.54 to 5.00 MPa), shear stresses (9.69 to 29.71 MPa), and efficiency (1.16 to 3.16) during repeated testing. Scanning electron microscopic images revealed minor deformations in the cutting edges of the tri-spade drills following testing.
Collapse
|
41
|
Corona SA, Borsatto M, Dibb RG, Ramos RP, Brugnera A, Pécora JD. Microleakage of class V resin composite restorations after bur, air-abrasion or Er:YAG laser preparation. Oper Dent 2001; 26:491-7. [PMID: 11551014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/21/2023]
Abstract
This in vitro study compared the microleakage of Class V resin composite restorations placed in cavities prepared with a high-speed dental bur, air-abrasion or Er:YAG laser. Twenty sound extracted human third molars were selected and randomly assigned to four equal Groups (n=10): Group I, cavities were cut by dental drill at high-speed; Group II, aluminum oxide air-abrasion was used for cavity preparation, and in Groups III and IV, cavities were prepared by Er:YAG laser. Following cavity preparation, Groups I and II were acid-etched, Group III was treated only by Er:YAG laser and Group IV was conditioned by Er:YAG laser followed by acid-etching. Cavities were restored (Single Bond + Z-100) and the teeth stored for seven days in distilled water. Then, the restorations were polished and the specimens thermocycled, immersed in a 0.2% Rhodamine solution, sectioned and analyzed for leakage at the occlusal (enamel) and cervical (dentin/cementum) interfaces using an optical microscope connected to a video camera. The images were digitized and software was utilized for microleakage assessment. Upon analyzing the results, statistically significant differences (p<0.01) between the occlusal and cervical regions for all groups was observed, and, as a rule, there was better marginal sealing at the enamel margins. The highest degree of infiltration was observed for cavities prepared and treated exclusively by Er:YAG (Group III). The other experimental groups showed statistical similarities in the amount of marginal leakage at the enamel margins. However, at the cervical margins, there was a significant difference (p<0.05) between Group I and the remaining groups. None of the techniques completely eliminated marginal microleakage at the dentin/ cementum margins.
Collapse
|
42
|
Gluskin AH, Brown DC, Buchanan LS. A reconstructed computerized tomographic comparison of Ni-Ti rotary GT files versus traditional instruments in canals shaped by novice operators. Int Endod J 2001; 34:476-84. [PMID: 11556516 DOI: 10.1046/j.1365-2591.2001.00422.x] [Citation(s) in RCA: 132] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
AIM The aim of this study was to compare the effects of preparation with conventional stainless steel Flexofiles and Gates Glidden burs versus nickel-titanium GT rotary files in the shaping of mesial root canals of extracted mandibular molars. METHODOLOGY A total of 54 canals from 27 mesial roots of mandibular molar teeth were prepared using one of two methods by novice dental students. One canal in each root was prepared by a crown-down approach. utilizing stainless steel Flexofiles and Gates Glidden burs. The other canal was prepared using nickel-titanium GT rotary files in a crown-down fashion as recommended by the manufacturer. Preoperative CT scans of each root were recorded and 50 canal specimens were available for postoperative comparisons. Following canal shaping, postoperative scans were superimposed on the original images. Changes in canal area, canal transportation and thickness of remaining root structure at strategic levels of the root were analyzed. The time taken for each method was also noted. RESULTS At the coronal and mid-root coronal one-third sections, the rotary GT files produced a significantly smaller postoperative canal area (P < 0.05). In the mid-root sections there was significantly less transportation of the root canal toward the furcation, and less thinning of the root structure with GT files compared to the stainless steel files (P < 0.05). Overall, there was greater conservation of structure coronally and more adequate shape in the mid-root level. The GT rotary technique was significantly faster than the stainless steel hand-held file technique (P < 0.0001). Two GT instruments fractured during the study. CONCLUSIONS Under the conditions of this study, novice dental students were able to prepare curved root canals with Ni-Ti GT rotary files with less transportation and greater conservation of tooth structure, compared to canals prepared with hand instruments. The rotary technique was significantly faster.
Collapse
|
43
|
Abstract
The purpose of this work was to investigate the process history on fracture life of nickel-titanium endodontics files. The results are based on microstructural investigations of nickel-titanium engine-driven rotary instruments based on X-ray diffraction, scanning electron microscopy, and microhardness tests. Endodontic files are very work-hardened, and there is a high density of defects in the alloy that can disturb the phase transformation. The microhardness Vickers confirmed these observations (dislocations and precipitates). The X-rays show that experimental spectrum lines are extended, typical of a distorted lattice. The surface state of the endodontic files (scanning electron microscopy) is an important factor in failure and fracture initiation.
Collapse
|
44
|
Ferraz CC, Gomes NV, Gomes BP, Zaia AA, Teixeira FB, Souza-Filho FJ. Apical extrusion of debris and irrigants using two hand and three engine-driven instrumentation techniques. Int Endod J 2001; 34:354-8. [PMID: 11482718 DOI: 10.1046/j.1365-2591.2001.00394.x] [Citation(s) in RCA: 123] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
AIM To evaluate the weight of debris and irrigant volume extruded apically from extracted teeth in vitro after endodontic instrumentation using the balanced force technique, a hybrid hand instrumentation technique, and three engine-driven techniques utilizing nickel-titanium instruments (ProFile .04, Quantec 2000 and Pow-R). METHODOLOGY Five groups of 20 extracted human teeth with single canals were instrumented using one or other of five techniques: balanced force, hybrid, Quantec 2000, ProFile .04, or Pow-R. Debris extruded from the apical foramen during instrumentation were collected into preweighed 1.5 mL tubes. Following instrumentation, the volume of extruded irrigant fluid was determined by visual comparison to control centrifuge tubes filled with 0.25 mL increments of distilled water. The weight of dry extruded dentine debris was also established. RESULTS Overall, the engine-driven techniques extruded less debris than the manual ones. However, there was no statistical difference between the balanced force technique and the engine-driven methods. The volume of irrigant extruded through the apex was directly associated with the weight of extruded debris, except within the ProFile group. The hybrid technique was associated with the greatest extrusion of both debris and irrigant. CONCLUSIONS Overall, the engine-driven nickel-titanium systems were associated with less apical extrusion.
Collapse
|
45
|
Abstract
AIM The purpose of the present study was to evaluate resistance to cyclic fatigue of new and used ProFile Ni-Ti rotary instruments. METHODOLOGY Used instruments were operated in 10 clinical cases using passive instrumentation and a crown-down preparation technique. Cyclic fatigue testing of new and used engine-driven instruments was then performed with a specific device which allowed the instruments to rotate freely inside a stainless steel artificial canal, whilst maintaining conditions close to the clinical situation. Instruments were rotated until fracture occurred and time to fracture was visually recorded with a chronometer. RESULTS A significant reduction of rotation time to breakage (life span) was noted between new and used instruments. In all sizes new instruments were significantly more resistant than used ones (two-sample t-test, P < 0.01). No instrument underwent intracanal failure during clinical use. CONCLUSIONS Prolonged clinical use of Ni-Ti engine-driven instruments significantly reduced their cyclic fatigue resistance. Nevertheless, each rotary instrument was successfully operated in up to 10 clinical cases without any intracanal failure.
Collapse
|
46
|
Dietschi JM, Dietschi D, Krejci I. Nickel-titanium rotary instruments: review and strategy for development of a new instrument. PRACTICAL PROCEDURES & AESTHETIC DENTISTRY : PPAD 2001; 13:385-9. [PMID: 11504456] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/21/2023]
|
47
|
Zhong M, Jost-Brinkmann PG, Zellmann M, Zellmann S, Radlanski RJ. Clinical evaluation of a new technique for interdental enamel reduction. J Orofac Orthop 2001; 61:432-9. [PMID: 11126018 DOI: 10.1007/pl00001911] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
In orthodontics, reduction of tooth-size by grinding interproximal surfaces (stripping) of teeth is a common procedure. In order to achieve perfectly smooth surfaces, clinicians have carefully tested various methods and progressively improved this therapeutic procedure. In this in-vivo study we used scanning electron microscopy (SEM) to evaluate the morphologic effect of a 3-step technique using an oscillating perforated diamond-coated disc for enamel reduction and 2 Sof-Lex XT discs for polishing. This technique was applied in 32 patients with an average age of 15.5 years. A total of 296 interproximal surfaces was treated and replicas were produced for scanning electron microscopy evaluation. The scanning electron microscopy investigations demonstrated that more than 90% of the reproximated surfaces were very well or well polished, resulting in polished enamel surfaces smoother than untreated enamel. This technique proved to be clinically expedient as it finished each interproximal surface within about 2.2 minutes. At the same time, it was demonstrated to be safe and comfortable for the patient, eliminating the need for lip or cheek protectors and making injuries unlikely.
Collapse
|
48
|
Maragakis GM, Hahn P, Hellwig E. Clinical evaluation of chemomechanical caries removal in primary molars and its acceptance by patients. Caries Res 2001; 35:205-10. [PMID: 11385201 DOI: 10.1159/000047457] [Citation(s) in RCA: 50] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
Abstract
The purpose of this study was to evaluate the clinical efficiency and patient acceptance of the chemomechanical caries removal agent Carisolvtrade mark in deciduous teeth. Contralateral primary molars of sixteen 7- to 9-year-old patients (32 teeth) were treated with the air-motor and with Carisolv, respectively. Patients replied to a pre- and a postoperative questionnaire. Complete caries removal (CCR) was accomplished in all air-motor sessions. It was not achieved within the time limit of 15 min in 6 (37.5%) Carisolv sessions. Air-motor CCR time ranged between 6 and 18 s (mean: 11.81 s ). Carisolv CCR time, where accomplished within 15 min, ranged between 6 min 46 s and 13 min 57 s (mean: 6 min 51 s). Preoperatively, the majority of the children reported disliking the drilling, and that they would visit the dentist more often and prefer sitting in the chair longer if they could avoid it. Postoperatively, the majority of the children reported disliking the taste of Carisolv, estimated Carisolv to have taken longer, would not recommend it to their friends, and preferred the air-motor. In conclusion, Carisolv, although a step forward in terms of solution volume required, is not in a position to replace rotary instruments for caries removal: it did not remove decay completely in one third of our sample; it was much slower than the air-motor; it had a chlorine taste/odor our patients disliked.
Collapse
|
49
|
Ayad MF. Effects of rotary instrumentation and different etchants on removal of smear layer on human dentin. J Prosthet Dent 2001; 85:67-72. [PMID: 11174681 DOI: 10.1067/mpr.2001.112792] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
STATEMENT OF PROBLEM Various methods of rotary preparation and conditioning of teeth affect surface topography and may affect the retention of dental restorations. PURPOSE This study microscopically evaluated dentin surfaces prepared by different rotary instruments and etched using several types of acid etchants that have been deemed suitable dentin conditioners. MATERIAL AND METHODS Occlusal surfaces of 35 extracted human molars were ground wet with 320-grit silicon carbide paper to the depth of the central groove and then prepared with diamond (n = 5) and finishing burs (n = 30). Five specimens from each group were used for SEM evaluation of mechanical preparation effects. Dentin specimens (n = 5) prepared with finishing burs were then etched with 1 of 5 etchants (25% polyacrylic acid, 10% phosphoric acid, 10% citric acid, 20% lactic acid, or 32% phosphoric acid) for 10 seconds. Specimens were critical-point dried and freeze fractured for SEM analysis. RESULTS Diamond rotary instruments created more undulating surfaces than finishing burs. Fine grooves were observed running perpendicular to undulations and parallel to the direction of instrument rotation. Specimens prepared with finishing burs exhibited a smooth surface interrupted by only a slight granularity. The amorphous smear layer was partially removed after the application of 25% polyacrylic acid (pH 1.53), but all dentinal tubules contained plugs. The number of dentin tubules containing plug material and the amount of material in the tubules decreased noticeably with 10% phosphoric acid (pH 0.86), and the dentin surface had an appearance similar to the specimen etched with 10% citric acid (pH 1.70). The surfaces treated with 20% lactic acid (pH 1.40) produced a clearly etched surface with minimal demineralization. Etching of dentin with 32% phosphoric acid (pH 0.16) revealed significant changes in dentin with the evidence of increased tubule diameter. CONCLUSION Differences related to the method of instrumentation were found in the surface characteristics of dentin. The degree of smear layer removal was related to the pH of the acid etchant.
Collapse
|
50
|
Abstract
BACKGROUND Tooth preparation requires safe, efficient and rapid cutting, and diamond burs routinely are used for extracoronal preparation and gross tooth reduction. Coarser-grit diamond burs often are used for gross tooth reduction, with tooth surface finishes being sacrificed for the presumed greater cutting rates, or CRs, of the coarser diamond burs. The authors compared the CRs of medium-, coarse- and super-coarse-grit diamond burs. METHODS The authors used a self-contained dental treatment system with digitally controlled handpiece speed, torque and water flow rate to cut a machinable glass ceramic cutting substrate with medium-, coarse- and super-coarse-grit diamond burs from the same manufacturer under a load of 147.5 grams (0.9 kilonewton at the bur tip) and a coolant flow rate of 22 milliliters per minute. They made three cuts through 13-millimeter bars of the cutting substrate with six diamond burs of each grit size. They determined CRs as the transection time per millimeter and analyzed CR data by one-way analysis of variance and post hoc Scheffé tests. RESULTS The authors found no statistically significant difference in CR (P > .05) between the three diamond bur grit sizes for the first (13 mm) cuts. When they compared the three cuts (39 mm total cut length), they found no difference (P > .05) between CRs for coarse- and super-coarse-grit diamond burs, but they did find that the super-coarse-grit diamond burs cut faster than the medium-grit diamond burs (P < .01). CONCLUSION Differences in CR for the three diamond bur grit sizes are due to the greater decrease in CR for the medium-grit diamond burs (50 percent) compared with the CRs of the coarse- and super-coarse-grit diamond burs (35 percent and 25 percent, respectively) over the total cutting period. CLINICAL IMPLICATIONS Coarser-grit diamond burs may be useful for extensive gross tooth preparations, but dental professionals should be aware of the associated effects of the coarser grit on surface finish, heat generation and enamel damage.
Collapse
|