51
|
Cluver C, Novikova N, Hofmeyr GJ, Hall DR. Maternal position during caesarean section for preventing maternal and neonatal complications. Cochrane Database Syst Rev 2013:CD007623. [PMID: 23543552 DOI: 10.1002/14651858.cd007623.pub3] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
BACKGROUND During caesarean section mothers can be in different positions. Theatre tables could be tilted laterally, upwards, downwards or flexed and wedges or cushions could be used. There is no consensus on the best positioning at present. OBJECTIVES We assessed all available data on positioning of the mother to determine if there is an ideal position during caesarean section that would improve outcomes. SEARCH METHODS We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (20 August 2012), PubMed (1966 to 20 August 2012) and manually searched the references of retrieved articles. SELECTION CRITERIA Randomised trials of woman undergoing caesarean section comparing different positions. DATA COLLECTION AND ANALYSIS Two review authors assessed eligibility, trial quality and extracted data. MAIN RESULTS We identified 22 studies with a total of 857 women included. We included 11 studies and excluded 11. Included trials were of variably quality with small sample sizes. Most comparisons had data from single trials. This is a shortcoming and applicability of results is limited.The incidence of air embolism was not affected by head up versus horizontal position (average risk ratio (RR) 0.85; 95% confidence interval (CI) 0.28 to 2.57; Tau² = 0.50; I² = 74%).We found no change in hypotensive episodes when comparing left lateral tilt (RR 0.11; 95% CI 0.01 to 1.94), right lateral tilt (RR 1.25; 95% CI 0.39 to 3.99), a right lumbar pelvic wedge (RR 0.85; CI 0.53 to1.37) and head down tilt (RR 1.07; 95% CI 0.81 to 1.42) with horizontal positions. We found no change in hypotensive episodes when comparing full lateral tilt with 15-degree tilt (RR 1.20; 95% CI 0.80 to 1.79). Hypotensive episodes were decreased with manual displacers (RR 0.11; 95% CI 0.03 to 0.45), and increased with a right lumbar wedge compared with a right pelvic wedge (RR 1.64; 95% CI 1.07 to 2.53) and increased with a right lateral tilt compared with a left lateral tilt (RR 3.30; 95% CI 1.20 to 9.08).Position did not affect systolic blood pressure when comparing left lateral tilt (MD 2.70; 95% CI -1.47 to 6.87) or head down tilt (MD -3.00; 95% CI -8.38 to 2.38) with horizontal positions, or full lateral tilt with 15-degree tilt (MD -5.00; 95% CI -11.45 to 1.45). Manual displacers showed decreased fall in mean systolic blood pressure compared with left lateral tilt (MD -8.80; 95% CI -13.08 to -4.52).Position did not affect diastolic blood pressures when comparing left lateral tilt versus horizontal positions (MD-1.90; 95% CI -5.28 to 1.48). The mean diastolic pressure was lower in head down tilt (MD -7.00; 95% CI -12.05 to -1.95) when compared with horizontal positions.There were no statistically significant changes in maternal pulse rate, five-minute Apgars, maternal blood pH or cord blood pH when comparing different positions. AUTHORS' CONCLUSIONS There is limited evidence to support or clearly disprove the value of the use of tilting or flexing the table, the use of wedges and cushions or the use of mechanical displacers. A left lateral tilt may be better than a right lateral tilt and manual displacers may be better than a left lateral tilt but larger studies with more robust data are needed to confirm these findings.
Collapse
|
52
|
Sharma A, Chatterjee S. Clinical valve of myocardial contrast delayed enhancement with multidetector computed tomography. J Am Coll Cardiol 2012; 60:563; author reply 563-4. [PMID: 22858292 DOI: 10.1016/j.jacc.2012.02.074] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/21/2012] [Accepted: 02/23/2012] [Indexed: 12/01/2022]
|
53
|
Kelting T. Commentary on: Air bubble detector placement in the CPB circuit: a 2011 cross-sectional analysis of the practice of Certified Clinical Perfusionists. Perfusion 2012; 27:352. [PMID: 22730349 DOI: 10.1177/0267659112449251] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
54
|
Abstract
Clinically significant carbon dioxide embolism is a rare but potentially fatal complication of anesthesia administered during laparoscopic surgery. Its most common cause is inadvertent injection of carbon dioxide into a large vein, artery or solid organ. This error usually occurs during or shortly after insufflation of carbon dioxide into the body cavity, but may result from direct intravascular insufflation of carbon dioxide during surgery. Clinical presentation of carbon dioxide embolism ranges from asymptomatic to neurologic injury, cardiovascular collapse or even death, which is dependent on the rate and volume of carbon dioxide entrapment and the patient's condition. We reviewed extensive literature regarding carbon dioxide embolism in detail and set out to describe the complication from background to treatment. We hope that the present work will improve our understanding of carbon dioxide embolism during laparoscopic surgery.
Collapse
|
55
|
Ingelmo Ingelmo I, Fábregas Juliá N, Rama-Maceiras P, Rubio Romero R, Badenes Quiles R, Valencia Sola L, Romero Krauchi O, Honorato C, Hernández Palazón J, Sánchez Ledesma MJ. [Questionnaire on the anaesthesiology treatment of patients subjected to posterior fossa neurosurgery]. REVISTA ESPANOLA DE ANESTESIOLOGIA Y REANIMACION 2012; 59:118-126. [PMID: 22985752 DOI: 10.1016/j.redar.2012.02.031] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/23/2011] [Accepted: 02/10/2012] [Indexed: 06/01/2023]
Abstract
OBJECTIVES To find out, by means of a questionnaire, the procedures used by Spanish anaesthetists in peri-operative management of patients subjected to neurosurgery of the posterior cranial fossa. MATERIAL AND METHODS A closed-question type questionnaire was sent to Anaesthesiology Departments with a Neurosurgery Department on the participation of anaesthetists in the peri-operative treatment of patients subjected posterior fossa surgery. RESULTS The questionnaire was completed by 42 (57.5%) of the 73 national public hospitals with a Neurosurgery Department. The posterior fossa surgery was performed in the sitting position in 36 hospitals, although it was less frequently used than the lateral decubitus or prone decubitus position. There was little specific neurological monitoring, as well as little use of precordial and/or transcranial Doppler for detecting vascular air embolism. Nitrous oxide was used in less than 10% of the centres, and 15% avoided neuromuscular block when neurophysiological monitoring was used during the surgery. Cardiovascular problems were mentioned as being the most frequent in 29% of the centres, while in the post-operative period the most common complications were, cranial nerve déficit, airway oedema (23%), and post-operative vomiting (47%). CONCLUSIONS The results obtained from the questionnaire showed that the sitting position was less used than the prone position in posterior fossa surgery, and that neurophysiological monitoring is during surgery is hardly used.
Collapse
MESH Headings
- Adult
- Airway Obstruction/epidemiology
- Airway Obstruction/etiology
- Anesthesia/methods
- Anesthesia Department, Hospital/statistics & numerical data
- Anesthesia, Inhalation/statistics & numerical data
- Anesthesia, Intravenous/statistics & numerical data
- Anesthetics, Inhalation
- Cardiovascular Diseases/diagnosis
- Cardiovascular Diseases/epidemiology
- Child
- Cranial Fossa, Posterior/surgery
- Cranial Nerve Diseases/epidemiology
- Cranial Nerve Diseases/etiology
- Drug Utilization
- Embolism, Air/diagnostic imaging
- Embolism, Air/prevention & control
- Health Care Surveys
- Hospital Departments/statistics & numerical data
- Hospitals, Public/statistics & numerical data
- Humans
- Intraoperative Complications/diagnosis
- Intraoperative Complications/diagnostic imaging
- Intraoperative Complications/prevention & control
- Monitoring, Intraoperative/statistics & numerical data
- Neuromuscular Blocking Agents
- Neuromuscular Monitoring/statistics & numerical data
- Neurosurgery/organization & administration
- Neurosurgical Procedures
- Nitrous Oxide
- Patient Positioning
- Pneumocephalus/epidemiology
- Pneumocephalus/etiology
- Postoperative Complications/epidemiology
- Postoperative Nausea and Vomiting/epidemiology
- Surveys and Questionnaires
- Ultrasonography, Doppler, Transcranial/statistics & numerical data
Collapse
|
56
|
Schellart NAM, Sterk W. Venous gas embolism after an open-water air dive and identical repetitive dive. Undersea Hyperb Med 2012; 39:577-587. [PMID: 22400448] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
Decompression tables indicate that a repetitive dive to the same depth as a first dive should be shortened to obtain the same probability of occurrence of decompression sickness (pDCS). Repetition protocols are based on small numbers, a reason for re-examination. Since venous gas embolism (VGE) and pDCS are related, one would expect a higher bubble grade (BG) of VGE after the repetitive dive without reducing bottom time. BGs were determined in 28 divers after a first and an identical repetitive air dive of 40 minutes to 20 meters of sea water. Doppler BG scores were transformed to log number of bubbles/cm2 (logB) to allow numerical analysis. With a previously published model (Model2), pDCS was calculated for the first dive and for both dives together. From pDCS, theoretical logBs were estimated with a pDCS-to-logB model constructed from literature data. However, pDCS the second dive was provided using conditional probability. This was achieved in Model2 and indirectly via tissue saturations. The combination of both models shows a significant increase of logB after the second dive, whereas the measurements showed an unexpected lower logB. These differences between measurements and model expectations are significant (p-values < 0.01). A reason for this discrepancy is uncertain. The most likely speculation would be that the divers, who were relatively old, did not perform physical activity for some days before the first dive. Our data suggest that, wisely, the first dive after a period of no exercise should be performed conservatively, particularly for older divers.
Collapse
|
57
|
Luettel D. Avoiding air embolism when removing CVCs. NURSING TIMES 2011; 107:23. [PMID: 23251971] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
|
58
|
Kuwahara T, Takahashi A, Takahashi Y, Kobori A, Miyazaki S, Takei A, Fujii A, Kusa S, Yagishita A, Okubo K, Fujino T, Nozato T, Hikita H, Sato A, Aonuma K. Clinical characteristics of massive air embolism complicating left atrial ablation of atrial fibrillation: lessons from five cases. Europace 2011; 14:204-8. [PMID: 21937478 DOI: 10.1093/europace/eur314] [Citation(s) in RCA: 46] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022] Open
|
59
|
Huehns T. Air embolus. NURSING TIMES 2011; 107:12. [PMID: 21827086] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
|
60
|
Medicaid program; payment adjustment for provider-preventable conditions including health care-acquired conditions. Final rule. FEDERAL REGISTER 2011; 76:32816-32838. [PMID: 21644388] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
This final rule will implement section 2702 of the Patient Protection and Affordable Care Act which directs the Secretary of Health and Human Services to issue Medicaid regulations effective as of July 1, 2011 prohibiting Federal payments to States under section 1903 of the Social Security Act for any amounts expended for providing medical assistance for health care-acquired conditions specified in the regulation. It will also authorize States to identify other provider-preventable conditions for which Medicaid payment will be prohibited.
Collapse
MESH Headings
- Accidental Falls/economics
- Accidental Falls/prevention & control
- Blood Group Incompatibility/economics
- Blood Group Incompatibility/prevention & control
- Catheter-Related Infections/economics
- Catheter-Related Infections/prevention & control
- Diabetic Ketoacidosis/economics
- Diabetic Ketoacidosis/prevention & control
- Economics, Hospital/legislation & jurisprudence
- Embolism, Air/economics
- Embolism, Air/prevention & control
- Foreign Bodies/economics
- Foreign Bodies/prevention & control
- Health Care Reform/economics
- Health Care Reform/legislation & jurisprudence
- Humans
- Insurance, Health, Reimbursement/economics
- Insurance, Health, Reimbursement/legislation & jurisprudence
- Legislation, Hospital/economics
- Medicaid/economics
- Medicaid/legislation & jurisprudence
- Medical Errors/economics
- Medical Errors/prevention & control
- Medicare/economics
- Medicare/legislation & jurisprudence
- Patient Protection and Affordable Care Act/economics
- Pressure Ulcer/economics
- Pressure Ulcer/prevention & control
- Prospective Payment System/economics
- Prospective Payment System/legislation & jurisprudence
- Quality Assurance, Health Care/economics
- Quality Assurance, Health Care/legislation & jurisprudence
- Surgical Wound Infection/economics
- Surgical Wound Infection/prevention & control
- United States
- Venous Thrombosis/economics
- Venous Thrombosis/prevention & control
Collapse
|
61
|
Simons AP, Weerwind PW. Microbubble formation during minimized cardiopulmonary bypass. Artif Organs 2011; 35:554; author reply 555. [PMID: 21595724 DOI: 10.1111/j.1525-1594.2011.01239.x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
62
|
Talor J, Ündar A. An in vitro comparison of the ability of three commonly used pediatric cardiopulmonary bypass circuits to filter gaseous microemboli. Perfusion 2010; 26:167-8. [PMID: 21173038 DOI: 10.1177/0267659110392437] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
63
|
Nazzaro JM, Lyons KE, Honea RA, Mayo MS, Cook-Wiens G, Harsha A, Burns JM, Pahwa R. Head positioning and risk of pneumocephalus, air embolism, and hemorrhage during subthalamic deep brain stimulation surgery. Acta Neurochir (Wien) 2010; 152:2047-52. [PMID: 20862499 DOI: 10.1007/s00701-010-0776-5] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2010] [Accepted: 08/12/2010] [Indexed: 12/31/2022]
Abstract
PURPOSE The objective of the present study was to evaluate the risk of pneumocephalus, venous air embolism (VAE), and intracranial hemorrhage in subthalamic nucleus (STN) deep brain stimulation (DBS) patients operated in the strict supine (head and body flat) position. METHODS This was a retrospective review of clinical records and brain imaging of patients who underwent STN DBS between January 2007 and June 2009 at the University of Kansas Medical Center. RESULTS A total of 61 patients underwent 114 lead implantations (53 staged bilateral and 8 unilateral). No case involved a transventricular route. Intracranial air volumes ranged from 0 to 7.02 cm³ (mean 0.98 ± 1.42 cm³). Pneumocephalus volumes were highly skewed with no air present after 44 (38.6%) lead implantations, >0 to 1 cm³ in 35 (30.7%), >2 to 3 cm³ in 17 (14.9%), and >3 cm³ (average 4.97 cm³) in 9 (7.9%). There was no incidence of clinically apparent VAE or symptomatic intracranial hemorrhage. There was no association between age, degree of atrophy, sagittal angle of surgical approach, number of microelectrode runs (MERs), distance of gyrus from inner skull bone at the entry point, or surgical side and pneumocephalus. However, the majority of lead implantations (100 leads; 88%) required only one MER and there were minimal measurable distances between entered gyrus and adjacent bone. CONCLUSIONS Our data suggest that strict supine positioning during STN DBS surgery results in minimal intracranial air and is not associated with VAE or symptomatic intracranial hemorrhage when the operative method described is used.
Collapse
|
64
|
Sleep J, Syhre I, Evans E. Blood temperature management and gaseous microemboli creation: an in-vitro analysis. THE JOURNAL OF EXTRA-CORPOREAL TECHNOLOGY 2010; 42:219-222. [PMID: 21114225 PMCID: PMC4679962] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Received: 06/28/2009] [Accepted: 08/15/2010] [Indexed: 05/30/2023]
Abstract
Gaseous microemboli have been associated with post operative neurological deficits in patients undergoing cardiopulmonary bypass. Creating an optimal perfusion system that minimizes microemboli production and has enhanced abilities to sequester entrained air during the bypass procedure has been an important focus. This study examines the air-handling capabilities of a cardiopulmonary bypass circuit and correlates blood temperatures with microemboli loads proximal and distal to the arterial line filter within the circuit. Utilizing a Capiox RX25R oxygenator, Capiox 37 micron arterial filter, vacuum assisted venous return, and emboli detectors, 30 mL of air were injected into the venous line of a bypass circuit at eight different temperatures. Emboli were counted distal to the arterial line filter by the EDAQ Quantifier (Emboli Detection and Classification). The average number of emboli detected distal to the arterial filter progressively increased as the perfusate temperature was dropped. At 37.0 degrees C an average of 1.4 emboli was observed distal to the arterial filter within 90 seconds of the air injection. At 23.0 degrees C an average of 49.8 emboli was detected. Air introduced into the venous side of the bypass circuit resulted in showers of microemboli being sent past the arterial line filter. In addition, as the bovine blood was cooled, the air handling capability of the circuit was diminished.
Collapse
|
65
|
Gill MC, Dando H, John D. Is the air handling capability of the quadrox D pump dependent within an ECMO circuit? An in vitro study. THE JOURNAL OF EXTRA-CORPOREAL TECHNOLOGY 2010; 42:203-211. [PMID: 21114223 PMCID: PMC4679960] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Received: 12/15/2009] [Accepted: 07/19/2010] [Indexed: 05/30/2023]
Abstract
The occurrence of gaseous microemboli (GME) within the extracorporeal membrane oxygenation circuit is largely overlooked, as are methods to ameliorate this occurrence. We aimed to determine if the air handling capability of the Quadrox D oxygenator was dependent upon whether it was used in conjunction with a centrifugal or roller pump; and if application of a Pall air eliminating filter (AEF) would prevent circuit air introduction from intravenous infusions. Using a blood primed circuit 1 mL of air was infused pre pump. GME were quantified post pump and post oxygenator using the EDAC Quantifier. Trials were conducted at 1 and 2 L/min flow. To prevent GME recirculation a Capiox SX18 was used in circuit with negative pressure applied to its oxygenator; an EDAC cuvette distal to this device quantified GME recirculation. Following air infusion, 3-5 minute data recordings were carried out for each trial. Separate trials were carried out for centrifugal and roller pumps, and for each flow rate. The process was then repeated following the application of the AEF to the air infusion line. More GME were detected post Quadrox D when the centrifugal pump was used in comparison to the roller pump at 1 L/min (p < .05), and 2 L/min (p = .05). A greater volume of air was detected post Quadrox D when used in conjunction with the centrifugal device at 1 L/min (p < or = .05), and 2 L/min (p < or = .05). Application of the AEF resulted in zero GME detected at any circuit location. The results of this study confirm that a greater total count and volume of GME are detected distal to the Quadrox D when used in conjunction with a Rotaflow centrifugal pump. Application of a Pall AEF to infusion and drug lines can prevent air introduction from this source.
Collapse
|
66
|
Moon R, Butler FK. RE: Cerebral air embolism following removal of central venous catheter, published in [Mil Med 2009: 174(8): 878-81]. Mil Med 2010; 175:xvi. [PMID: 20882921] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/29/2023] Open
|
67
|
Simons AP, Weerwind PW. Evaluation of Quadrox-i adult hollow fiber oxygenator with integrated arterial filter. THE JOURNAL OF EXTRA-CORPOREAL TECHNOLOGY 2010; 42:242-243. [PMID: 21114230 PMCID: PMC4679967] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
|
68
|
McCrary BF. RE: Cerebral air embolism following removal of central venous catheter, published in [Mil Med 2009: 174(8): 878-81]. Mil Med 2010; 175:xvi-xvii. [PMID: 20886694] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/29/2023] Open
|
69
|
Cluver C, Novikova N, Hofmeyr GJ, Hall DR. Maternal position during caesarean section for preventing maternal and neonatal complications. Cochrane Database Syst Rev 2010:CD007623. [PMID: 20556781 DOI: 10.1002/14651858.cd007623.pub2] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
BACKGROUND During caesarean section mothers can be in different positions. Theatre tables could be tilted laterally, upwards, downwards or flexed and wedges or cushions could be used. There is no consensus on the best positioning at present. OBJECTIVES We assessed all available data on positioning of the mother to determine if there is an ideal position during caesarean section that would improve outcomes. SEARCH STRATEGY We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (September 2009), PubMed (1966 to 14 September 2009) and manually searched the references of retrieved articles. SELECTION CRITERIA Randomised trials of woman undergoing caesarean section comparing different positions. DATA COLLECTION AND ANALYSIS Two authors assessed eligibility, trial quality and extracted data. MAIN RESULTS We identified 17 studies with a total of 683 woman included. We included nine studies and excluded eight studies. Included trials were of variably quality with small sample sizes. Most comparisons had data from single trials. This is a shortcoming and applicability of results is limited.The incidence of air embolism was not affected by head up versus horizontal position (risk ratio (RR) 0.91; 95% confidence interval (CI) 0.65 to 1.26). We found no change in hypotensive episodes when comparing left lateral tilt (RR 0.11; 95% CI 0.01 to 1.94), right lateral tilt (RR 1.25; 95% CI 0.39 to 3.99) and head down tilt (mean difference (MD) -3.00; 95% CI -8.38 to 2.38) with horizontal positions or full lateral tilt with 15-degree tilt (RR 1.20; 95% CI 0.80 to 1.79). Hypotensive episodes were decreased with manual displacers (RR 0.11; 95% CI 0.03 to 0.45), a right lumbar wedge compared to a right pelvic wedge (RR 1.64; 95% CI 1.07 to 2.53) and increased in right lateral tilt (RR 3.30; 95% CI 1.20 to 9.08) versus left lateral tilt.Position did not affect systolic blood pressure when comparing left lateral tilt (MD 2.70; 95% CI -1.47 to 6.87) or head down tilt (RR 1.07; 95% CI 0.81 to 1.42) to horizontal positions, or full lateral tilt with 15-degree tilt (MD -5.00; 95% CI -11.45 to 1.45). Manual displacers showed decreased fall in mean systolic blood pressure compared to left lateral tilt (MD -8.80; 95% CI -13.08 to -4.52).Position did not affect diastolic blood pressures when comparing left lateral tilt versus horizontal positions. (MD-1.90; 95% CI -5.28 to 1.48). The mean diastolic pressure was lower in head down tilt (MD -7.00; 95% CI -12.05 to -1.95) when compared to horizontal positions.There were no statistically significant changes in maternal pulse rate, five-minute Apgars, maternal blood pH or cord blood pH when comparing different positions. AUTHORS' CONCLUSIONS There is limited evidence to support or clearly disprove the value of the use of tilting or flexing the table, the use of wedges and cushions or the use of mechanical displacers. Larger studies are needed.
Collapse
|
70
|
Angiography contrast injector safety. Visualizing the marketplace. HEALTH DEVICES 2010; 39:182-193. [PMID: 21309283] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
The most common risk associated with angiography contrast injectors is air embolism. Injector manufacturers have attempted to address this concern by adding air detection systems and other safety features. Find out which injectors do the best job of protecting patients.
Collapse
|
71
|
von Jürgensonn S. Prevention and management of air in an IV infusion system. BRITISH JOURNAL OF NURSING (MARK ALLEN PUBLISHING) 2010; 19:S28-S30. [PMID: 20622771 DOI: 10.12968/bjon.2010.19.sup3.48215] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
When air enters the circulatory system of the human body it can cause an air embolism. Air in the venous circulation will enter the right side of the heart where it may cause right ventricular outflow tract obstruction and acute pulmonary hypertension from pulmonary vasoconstriction. This compromises the pulmonary venous return to the left side of the heart, resulting in significant reduction in cardiac output and cardiovascular collapse. Air can pass into the left side of the heart via a patent foramen ovale or a septal defect. From the left side of the heart air will then enter the arterial circulation where it may embolize cerebral or coronary arteries with fatal consequences. Prevention of air embolism is therefore of utmost importance.
Collapse
|
72
|
Svenarud P, Persson M, van der Linden J. A complementary technique to carbon dioxide de-airing in open cardiac operations? J Thorac Cardiovasc Surg 2010; 139:512-3; author reply 513-4. [PMID: 20106409 DOI: 10.1016/j.jtcvs.2009.09.056] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/07/2009] [Accepted: 09/10/2009] [Indexed: 11/18/2022]
|
73
|
McCrary BF. Re: Cerebral air embolism following removal of central venous catheter. Mil Med 2009; 174:xii-xiii. [PMID: 20058370] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/28/2023] Open
|
74
|
Moon R, Butler FK. Treatment of arterial gas embolism. Mil Med 2009; 174:xii. [PMID: 20055057] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/28/2023] Open
|
75
|
Preston TJ, Gomez D, Olshove VF, Phillips A, Galantowicz M. Clinical gaseous microemboli assessment of an oxygenator with integral arterial filter in the pediatric population. THE JOURNAL OF EXTRA-CORPOREAL TECHNOLOGY 2009; 41:226-30. [PMID: 20092077 PMCID: PMC4813539] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Received: 03/09/2009] [Accepted: 09/01/2009] [Indexed: 05/28/2023]
Abstract
The use of an arterial line filter (ALF) within the pediatric cardiopulmonary bypass (CPB) circuit is not a new concept. It has always presented the perfusionist with a circuit component that while valuable, increased prime volume. The purpose of this study was to evaluate the change in prime volume and emboli between a conventional oxygenator with separate ALF and a new generation oxygenator with integral arterial filter (AF). We performed a clinical, non-randomized retrospective evaluation of the Terumo Capiox RX15 (Terumo Cardiovascular Systems Corporation, Ann Arbor, MI) (n = 10) in conjunction with the Terumo Capiox AF125X ALF or the Capiox AF02 vs. the Terumo Capiox FX15 oxygenator with integral AF (n = 10). The above circuit components, in combination with the LUNA EDAC (emboli detection and classification) Quantifier (LUNA Innovations, Blacksburg, VA) were placed at various locations within each patient's CPB circuit to establish and quantify the presence and volume of gaseous emboli during all phases of cardiopulmonary bypass. The EDAC system is available/used for all patients undergoing CPB at this institution. When compared to a more conventional CPB circuit, the Capiox FX15 primes more easily as it does not require a carbon dioxide flush while still providing a 32 microm AF. There was no statistical difference in air handling between the tested oxygenators and their associated circuits. During this review it was determined that use of the Capiox FX15 simplifies the arterial limb of the pediatric CPB circuit. Removal of the separate ALF led to the removal of several, now unnecessary, arterial connectors and additional tubing (arterial line filter bypass). Removal of these components led to a reduction in prime volume and decreased the hemodilutional effect. The FX15 provided a safe, simplified pediatric CPB circuit and was as effective in gaseous microemboli removal as was the more traditional RX15 with separate ALF during this review.
Collapse
|
76
|
Mariani PJ, Cooney N. Air embolism's new scarlet letter. Undersea Hyperb Med 2009; 36:407-408. [PMID: 20112532] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
|
77
|
Beckman RR, Gisner C, Evans E. An in vitro study of the effectiveness of carbon dioxide flushing of arterial line filters. THE JOURNAL OF EXTRA-CORPOREAL TECHNOLOGY 2009; 41:161-5. [PMID: 19806799 PMCID: PMC4679951] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Received: 11/14/2008] [Accepted: 08/01/2009] [Indexed: 05/28/2023]
Abstract
Gaseous microemboli (GMEs) have been connected to neurologic impairment and other ischemic complications after surgery. The components of the extracorporeal circuit (ECC) have a large influence on GME production. This in vitro study investigates the use of carbon dioxide flushing of the 38-microm Medtronic Affinity CB351 and 38-microm Medtronic Affinity 351 arterial line filters (ALFs) to decrease GMEs and time for air to clear the ALE An adult circuit was implemented with a silicone oxygenator for vacuum-assisted gas removal and to reduce air before ALE The 48 filters were separated into four equal groups: flushed coated and non-coated and non-flushed coated and non-coated. Carbon dioxide flushing was performed at 6 L/min for 3 minutes. ALFs were retrograde primed at 200 mL/min. An Emboli Detection and Classification Quantifier (EDAC) was used to gather data. The average total emboli and time to clear (seconds) for flush coated were 20.25 +/- 16.78 and 142.17 +/- 174.80 seconds, respectively, flushed non-coated were 30.5 +/- 34.65 and 124.17 +/- 131.40 seconds, non-flushed coated were 162.08 +/- 79.90 and 390.42 +/- 84.36 seconds, and non-flushed non-coated were 163.67 +/- 212.67 and 305.92 +/- 179.36 seconds. Flushed filters had an average total emboli count of 25.375 +/- 27.14 and an average time to clear of 13.167 +/- 151.51 seconds. Non-flushed filters had an average total emboli count of 162.875 +/- 157.11 and an average time to clear of 348.167 +/- 143.70 seconds. Coated and non-coated filters for total emboli and time to clear had p values of .86 and .24, respectively. Flushed and non-flushed filters had total emboli and time to clear p values of < .001 and < .001, respectively. No significant difference was found between coated and non-coated filters involving total embolic count and time to clear. A significant difference was found in total embolic count and time to clear between flushed and non-flushed filters. This study shows that fewer emboli and faster embolic clearance time correlate with carbon dioxide flushing of the ALE.
Collapse
|
78
|
Hudacko A, Sievert A, Sistino J. Gaseous microemboli in a pediatric bypass circuit with an unprimed venous line: an in vitro study. THE JOURNAL OF EXTRA-CORPOREAL TECHNOLOGY 2009; 41:166-171. [PMID: 19806800 PMCID: PMC4679952] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Received: 03/31/2008] [Accepted: 05/17/2009] [Indexed: 05/28/2023]
Abstract
Miniaturizing cardiopulmonary bypass (CPB) circuits to reduce hemodilution and allogenic blood product administration is common in cardiac surgery. One major concern associated with smaller CPB circuits is a possible increase in gaseous microemboli (GME) sent to the cerebral vasculature, which is exacerbated by vacuum-assisted venous drainage (VAVD). The use of VAVD has increased with smaller venous line diameter and venous cannulae. This study examines the effects of CPB initiation with an unprimed venous line and VAVD in a pediatric circuit. A CPB circuit was set up with reservoir, oxygenator, and arterial filter with a bag reservoir to simulate the patient. All trials were done in vitro, and GME were measured using the EDAC Quantifier by Luna Innovations. EDAC sensors were placed proximal and distal to the oxygenator and distal to the arterial filter. Group 1 was the control group with no VAVD and a primed venous line. Groups 2, 3, and 4 used an unprimed venous line and VAVD of -40, -20, and -10 mmHg, respectively. Total microemboli counts and total embolic load in micrometers were measured at each sensor. Groups 2 (12,379.00 +/- 3180.37) and 3 (8296.67 +/- 2818.76) had significantly more microemboli than group 1 (923.33 +/- 796.08, p < .05) at the pre-oxygenator sensor. Group 2 (57.33 +/- 25.01, p < .05) had significantly more microemboli than group 1 (5.33 +/- 3.21) at the post-oxygenator sensor. No other findings were statistically significant. The results suggest that, if an oxygenator and arterial filter with sufficient air handling capabilities are used, this method to reduce prime volume may not increase GME in the arterial line distal to the arterial filter.
Collapse
|
79
|
Miller A, Lu CK, Wang S, Umstead TM, Freeman WM, Vrana K, Yang S, Myers JL, Phelps DS, Zahn JD, Ündar A. Pediatric cardiopulmonary bypass circuits: a review of studies conducted at the Penn State Pediatric Cardiac Research Laboratories. THE JOURNAL OF EXTRA-CORPOREAL TECHNOLOGY 2009; 41:P50-P58. [PMID: 19361042 PMCID: PMC4680234] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
Cardiopulmonary bypass (CPB) circuits are frequently necessary in the repair of congenital heart defects in infants and children. Although advances in technology and operative technique have decreased the mortality associated with cardiac procedures requiring CPB, post-operative neuro-cognitive outcome and the role of the CPB circuit in post-operative morbidity remains a significant concern. There are several factors that have been suggested to play a significant role in general post-operative outcome, including intraoperative inflammatory responses caused by the interaction of blood with circuit component surfaces, selection of appropriate perfusion mode to optimize organ function during CPB, and the introduction of gaseous microemboli into the patient's systemic circulation through circuit manipulations and modifications. These factors are the subject of continuing research at the Penn State Hershey Children's Hospital Pediatric Cardiac Research Laboratories, and this review will focus on the results of studies aimed at identifying circuit elements that affect the delivery of gaseous microemboli to the patient during CPB procedures, the role of anti-factor D monoclonal antibody in reducing systemic inflammation during CPB, and the results of preliminary plasma proteomics studies conducted on infants undergoing CPB.
Collapse
|
80
|
Bondi M, Cavaggioni A, Gasperetti A, Rubini A. A new method of measure of bubble gas volume shows that interleukin-6 injected into rats has no effect on gas embolism. Undersea Hyperb Med 2009; 36:103-115. [PMID: 19462750] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
The pleiotropic cytokine interleukin-6 increases in the plasma of rats after an air dive. Interleukin-6 shares both of inflammatory and anti-inflammatory properties and may condition the vascular system and gas embolism after an air dive. Up to now it is not known whether interleukin-6 has an effect on gas embolism. Aim of this work is to study the effect of interleukin-6 on gas embolism after a standard decompression protocol in a rat model. The volume of gas bubbles was measured in the heart cavities with a new method based on the buoyancy of the heart at different pressures which is physically sound, accurate and precise down to 10(-4) cm3. No effect was found after injecting physiological doses of interleukin-6 at different times before the air dive. The mortality of the rats in the first half hour after the decompression was associated with a substantial gas volume measured in the heart. Multi-variate logistic regression analysis showed that the female rats had a higher risk compared to male rats of developing a substantial bubble volume and of not surviving; the spring-summer season was a risk factor for the survival. Further studies are needed to see whether interleukin-6 in association with other cytokines has an effect on gas embolism.
Collapse
|
81
|
Xia EL. [Safety of hysteroscopic surgery]. ZHONGHUA FU CHAN KE ZA ZHI 2009; 44:99-102. [PMID: 19570418] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
|
82
|
Dick T. Bubbles: air-proofing your IV lines-pronto. JEMS : A JOURNAL OF EMERGENCY MEDICAL SERVICES 2009; 34:32. [PMID: 19269555 DOI: 10.1016/s0197-2510(09)70042-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
|
83
|
Abstract
Venous air embolism (VAE) is the entrapment of air or medical gases into the venous system causing symptoms and signs of pulmonary vessel obstruction. The incidence of VAE during cesarean delivery ranges from 10 to 97% depending on surgical position or diagnostic tools, with a potential for life-threatening events. We reviewed extensive literatures regarding VAE in detail and herein described VAE during surgery including cesarean delivery from background and history to treatment and prevention. It is intended that present work will improve the understanding of VAE during surgery.
Collapse
|
84
|
Abstract
In the second of two articles, the author identifies common complications associated with intravenous (i.v.) therapy and discusses preventive measures. Part one, published last week, provided an overview of i.v. therapy and the types of vascular access devices available.
Collapse
|
85
|
Palanchon P, Birmelé B, Tranquart F. Acoustical bubble trapper applied to hemodialysis. ULTRASOUND IN MEDICINE & BIOLOGY 2008; 34:681-684. [PMID: 17996355 DOI: 10.1016/j.ultrasmedbio.2007.09.014] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/23/2007] [Revised: 09/11/2007] [Accepted: 09/19/2007] [Indexed: 05/25/2023]
Abstract
Gaseous microemboli can arise in extracorporeal lines and devices such as dialysis machines. They are associated with severe pulmonary side effects in patients undergoing chronic hemodialysis sessions. The goal of this study was to develop a gaseous emboli trapper using ultrasound waves to remove any air bubble from the tubing system before they reach the patient. A homemade bubble trapper, developed in the laboratory, consists of a Perspex block containing a main channel connected to the tubing of a hemodialysis machine and a second subchannel positioned perpendicularly to the main one, used to trap the air microemboli. The microemboli flowing in the main channel were insonified through an acoustic window with an ultrasound wave, at a frequency of 500 kHz and with a maximal acoustic pressure of 500 kPa, generated by a single-element transducer positioned 3 cm away from the main flow. The radiation force induced by the ultrasound beam acts directly on the flowing air emboli, by pushing them into the subchannel. Two Doppler probes operating both at 2 MHz, connected to a DWL Doppler machine were placed before and after the bubble trapper to count sequentially the number of embolic events. The flow of the machine was varied between 200 mL/min and 500 mL/min. Depending on the flow velocity, the number of microembolic signals (MES) detected by the Doppler probes before and after the trapping system was identical and ranged from 5 to 150 MES/min in absence of the ultrasound irradiation. When the air bubble trapper was activated, a reduction of the number of MES, up to 70%, was achieved. Doppler recordings suggest that the circulating bubbles were either fragmented into smaller bubble fragments or directly got pushed into the second subchannel where they were collected. This simple approach using an ultrasound-based trapping system was shown to operate adequately with the current settings and can be used to filter air microemboli.
Collapse
|
86
|
Gupta R, Vora N, Thomas A, Crammond D, Roth R, Jovin T, Horowitz M. Symptomatic cerebral air embolism during neuro-angiographic procedures: incidence and problem avoidance. Neurocrit Care 2008; 7:241-6. [PMID: 17805494 DOI: 10.1007/s12028-007-0041-9] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
Abstract
BACKGROUND While clinically symptomatic cerebral air embolism secondary to neuro-angiographic procedures is rare, the incidence in a large series of procedures is unknown. Understanding this complication's frequency and etiology is critical if systems are to be instituted to reduce its incidence. METHODS We prospectively reviewed 4,568 consecutive neuro-angiographic procedures performed between June 2000 and July 2005. The occurrence and etiology of a symptomatic air embolus was noted, and an incidence was calculated for all procedures and for diagnostic arteriograms and interventional procedures individually. RESULTS Four symptomatic cerebral arterial air emboli occurred in 4,568 neuro-angiographic procedures over the five-year period (0.08%). No events occurred in 3,150 diagnostic angiograms while four occurred during 1,418 interventional procedures (0.2%). Two cases occurred during aneurysm coiling embolization (2/548; 0.4%); one case occurred during a carotid stent placement (1/138; 0.7%); one occurred during an internal carotid artery balloon occlusion test (1/73; 1.3%). Three of these complications resulted in permanent neurologic deficits while one resulted in a transient neurologic change that cleared within 60 min of onset. Sources for the emboli included the pressurized arterial flush lines connected to internal carotid artery catheters (three cases) and sudden hypotension with air subsequently entering the internal carotid artery catheter (one case). Two patients were treated with hyperbaric oxygen therapy. CONCLUSION Symptomatic cerebral air embolism is a rare event during neuro-angiographic procedures. Analysis of the etiologies of this infrequent event may permit us to further reduce its incidence.
Collapse
|
87
|
Riley JB. Arterial line filters ranked for gaseous micro-emboli separation performance: an in vitro study. THE JOURNAL OF EXTRA-CORPOREAL TECHNOLOGY 2008; 40:21-26. [PMID: 18389662 PMCID: PMC4680652] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
UNLABELLED Arterial line filters (ALFs) are arguably the most important component in the cardiopulmonary bypass circuit to protect the patient from gaseous macro- and micro-emboli (GME) originating in the perfusion circuit. The GME separating ability of 10 ALFs was ranked according to seven performance criteria. Ten ALFs rated between 20 and 43 microm were evaluated for flow resistance, the count, size, and volume of GME passed after a 10-mL room air bolus, and the ability to separate a high-count, 10- to 200-microm flowing distribution of GME. The Luna Innovations EDAC emboli detector was used to size, count, and sort GME. Three test trials were conducted for 3 each of the 10 filters. Performance criteria were correlated by regression analysis, statistically compared using analysis of variance, or ranked using non-parametric tests. Significance was set at 0.05. Weighting all seven test parameters equally, the most effective ALFs were the Cobe 21 and Gish 25-microm filters. The Pall LG-6 ranked more efficient than the Medtronic 20 and Dideco 27-microm filters. The Cobe 43, Terumo 40, Medtronic 38, Terumo 37, and Gish 40-microm filters were less effective as a group compared with the other filters. For the 10 filters, blood flow resistance was not correlated to rated pore size. Generally, the smaller the pore rating, the higher the GME separation ability rank, except for the leuko-reduction filter, which performed more effectively than other large pore filters. KEYWORDS arterial line filter, gaseous microemboli, in vitro test.
Collapse
|
88
|
Szabó Z, Träff S, Hermansson U, Tamás E, Maros T, Szentkirályi I. [A complementary clinical method to minimize air embolism during open-heart surgery]. Magy Seb 2008; 61 Suppl:57-59. [PMID: 18504240 DOI: 10.1556/maseb.61.2008.suppl.14] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
Air from the left heart is ejected even up to several hours after cardiopulmonary bypass (CPB) despite the use of CO2. The following method is complementary in addition to surgical de-airing in order to further reduce the chance of air embolism, especially from the pulmonary veins. After re-expanding the lungs with standard bag inflation, the ventilation is restarted in consultation with the surgeon. The ventilator is set to the respiratory minute volume used before the CPB but at a respiratory frequency of 10/minutes whereas the regularly beating heart is filled from the heart lung machine. Transoesophageal echocardiography (TEE) reliably controls the effect.
Collapse
|
89
|
Pierson R, Coupe M. Reducing the risk of air embolism following administration of intravenous paracetamol. Anaesthesia 2007; 63:104-5; discussion 105. [PMID: 18086092 DOI: 10.1111/j.1365-2044.2007.05392_1.x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
90
|
De Somer F. Impact of oxygenator characteristics on its capability to remove gaseous microemboli. THE JOURNAL OF EXTRA-CORPOREAL TECHNOLOGY 2007; 39:271-273. [PMID: 18293817] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
Since the advent of cardiopulmonary bypass, the generation and elimination of gaseous and solid (micro) emboli have been a concern. Major improvements with respect to gaseous microemboli have been made by the introduction of arterial line filtration and membrane oxygenators. Animal experiments have shown a clear correlation between massive air embolism and outcome. However, limited knowledge is available regarding the cut-off point between the occurrence of negative outcome and the number and size of gaseous microemboli. Generation of gaseous microemboli can occur when using cardiopulmonary bypass. However, no consensus exists on when a given diameter or number of emboli becomes injurious to the patient. An important variable is the gas mixture inside the bubble. Nitrogen has a very long dissolution time that results in a prolonged ischemia for tissue behind the occlusion. The pathophysiologic reaction of the body when exposed to gaseous microemboli is most likely based on ischemia caused by partial occlusion of blood vessels and by endothelial damage. Gaseous microemboli can be cleared mechanically by using filters, by reduction of blood velocity, and by rapid reduction of the nitrogen content. Elimination of gaseous microemboli is dependent on the design of the cardiopulmonary bypass circuit. A membrane oxygenator, although not designed for it, can remove gaseous microemboli. Arterial line filtration is not the best solution for removal of gaseous microemboli, because larger emboli have been fractionated before reaching the arterial filter. Venous line filtration is a more efficient way for clearing gaseous microemboli.
Collapse
|
91
|
Hsia TY, Gruber PJ. Factors influencing neurologic outcome after neonatal cardiopulmonary bypass: what we can and cannot control. Ann Thorac Surg 2007; 81:S2381-8. [PMID: 16731107 DOI: 10.1016/j.athoracsur.2006.02.074] [Citation(s) in RCA: 56] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/11/2005] [Revised: 02/10/2006] [Accepted: 02/13/2006] [Indexed: 10/24/2022]
Abstract
Advances in cardiopulmonary bypass and surgical techniques have led to progress in the early repair of congenital heart defects in children. However, as increasing numbers survive their initial cardiac operation, an awareness is emerging that significant early and late neurologic morbidities continue to complicate otherwise successful operative repairs. Adverse neurologic outcomes after neonatal cardiac surgery are multifactorial and relate to both fixed and modifiable mechanisms. The purpose of this review is to (1) review mechanisms of brain injury after neonatal cardiopulmonary bypass, (2) examine risk factors, and (3) speculate on how investigations may improve our understanding of neurologic injury.
Collapse
MESH Headings
- Alkalosis/prevention & control
- Brain Damage, Chronic/etiology
- Brain Damage, Chronic/physiopathology
- Brain Damage, Chronic/prevention & control
- Cardiopulmonary Bypass/adverse effects
- Cardiopulmonary Bypass/instrumentation
- Circulatory Arrest, Deep Hypothermia Induced
- Collateral Circulation
- Contraindications
- Disease Susceptibility
- Embolism, Air/etiology
- Embolism, Air/prevention & control
- Genetic Predisposition to Disease
- Heart Defects, Congenital/surgery
- Hemodilution
- Humans
- Hypoxia-Ischemia, Brain/etiology
- Hypoxia-Ischemia, Brain/prevention & control
- Infant
- Infant, Newborn
- Intracranial Embolism/etiology
- Intracranial Embolism/prevention & control
- Intraoperative Complications/etiology
- Intraoperative Complications/prevention & control
- Leukomalacia, Periventricular/epidemiology
- Leukomalacia, Periventricular/etiology
- Leukomalacia, Periventricular/prevention & control
- Monitoring, Intraoperative/methods
- Monitoring, Intraoperative/trends
- Postoperative Complications/etiology
- Postoperative Complications/prevention & control
- Preoperative Care
- Risk Factors
- Systemic Inflammatory Response Syndrome/etiology
- Systemic Inflammatory Response Syndrome/prevention & control
Collapse
|
92
|
Soonawalla ZF, Stratopoulos C, Stoneham M, Wilkinson D, Britton BJ, Friend PJ. Role of the reverse-Trendelenberg patient position in maintaining low-CVP anaesthesia during liver resections. Langenbecks Arch Surg 2007; 393:195-8. [PMID: 17805560 DOI: 10.1007/s00423-007-0222-1] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2006] [Accepted: 07/30/2007] [Indexed: 10/22/2022]
Abstract
BACKGROUND AND AIMS The Trendelenberg position is recommended during liver resection, to decrease the risk of venous air embolism. However, this position raises the central venous pressure and may increase blood loss. We propose that the reverse-Trendelenberg position can be safely and effectively used to maintain a low central venous pressure during liver surgery. MATERIALS AND METHODS Fifty consecutive patients underwent elective liver resection at a single centre during a 17-month period. Patients were positioned with a head-up tilt during division of the liver parenchyma. RESULTS Patients had a mean central venous pressure of 9.2 mmHg when supine, despite fluid restriction. The central venous pressure fell consistently and rapidly when they were tilted head-up, to a mean of 1.7 mmHg. The resections were completed with a median operative blood loss of 600 mL. No patient developed a clinically apparent venous air embolism. Postoperative renal dysfunction that could be attributed to low central venous pressure anaesthesia occurred in only one case. CONCLUSION The reverse-Trendelenberg position effectively lowers the CVP during liver surgery. It is easy to monitor, titrate and reverse, and avoids the need for complex pharmacological interventions. We recommend this position to liver surgeons and anaesthetists who have found it difficult to maintain a low CVP with the supine or Trendelenberg positions.
Collapse
|
93
|
Abstract
Positioning of the surgical patient is an important part of anesthesia care and attention to the physical and physiologic consequences of positioning can help prevent serious adverse events and complications. The general principles of patient positioning of the anesthetized and awake neurosurgical patient are discussed in this article.
Collapse
|
94
|
Myers GJ. Preventing gaseous microemboli during blood sampling and drug administration: an in vitro investigation. THE JOURNAL OF EXTRA-CORPOREAL TECHNOLOGY 2007; 39:192-198. [PMID: 17972455 PMCID: PMC4680731] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
The detection and prevention of gaseous microemboli (GMEs) during cardiopulmonary bypass has generated considerable interest within the cardiac surgical community. There have been several landmark papers that have used transcranial Doppler devices during cardiopulmonary bypass to detect gaseous microemboli activity in the patients' middle cerebral artery during perfusionist interventions. To determine if this source of emboli could be prevented, a shunt was developed between the oxygenator's sampling manifold and the oxygenator's venous line. This shunt bypassed the venous line and emptied into the oxygenator's integral cardiotomy. An in vitro experiment was performed using three open system oxygenators (Sorin Synthesis, Sorin PrimeOx2, and Terumo Capiox SX25) to compare post-arterial filter emboli detection using the Hatteland CMD20 Microbubble Detector under tightly controlled conditions. After injection of air through the sampling manifold, the PrimeOx2 and the Synthesis oxygenators had statistically significant fewer GMEs with the shunt used than when the shunt was not used. Using a shunt in the sampling manifold during perfusionist interventions will dramatically reduce or eliminate gaseous microemboli transmission to the patient during bypass with both the PrimeOx2 and Synthesis oxygenators. However, results indicate that further study of GME handling with all oxygenator's integral cardiotomies is warranted.
Collapse
|
95
|
Lee ACW. Elective removal of cuffed central venous catheters in children. Support Care Cancer 2007; 15:897-901. [PMID: 17103194 DOI: 10.1007/s00520-006-0182-y] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2006] [Accepted: 10/10/2006] [Indexed: 02/05/2023]
Abstract
BACKGROUND Subcutaneously tunneled, cuffed central venous catheters (CVCs) are commonly used in children undergoing cytotoxic chemotherapy or hematopoietic stem-cell transplantation. When their use is no longer indicated or precluded by mechanical or infectious complications, CVCs have to be removed. General instructions on how cuffed CVC should be removed are available in the medical texts but none is adapted for use in children. MATERIALS AND METHODS A literature search from the MEDLINE and EMBASE to identify articles describing the procedure of removing CVC or complications arising from the procedure was carried out. RESULTS Specific guidance on the removal of CVC in children was not found. Venous air embolism appeared to be the most common complication associated with catheter removal but none involved pediatric patients. On the other hand, three out of the five incidents of catheter fracture with or without embolization happened in children. CONCLUSION Further studies are needed to define the optimal management of CVC removal in pediatric patients. A sequence of positioning the child, use of sedation, dissecting out the cuff, pulling off the catheter, closing the exit wound, and handling of the removed catheter is suggested.
Collapse
|
96
|
|
97
|
Perthel M, El-Ayoubi L, Bendisch A, Laas J, Gerigk M. Clinical advantages of using mini-bypass systems in terms of blood product use, postoperative bleeding and air entrainment: an in vivo clinical perspective☆. Eur J Cardiothorac Surg 2007; 31:1070-5; discussion 1075. [PMID: 17337198 DOI: 10.1016/j.ejcts.2007.01.065] [Citation(s) in RCA: 42] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/21/2006] [Revised: 01/18/2007] [Accepted: 01/31/2007] [Indexed: 11/24/2022] Open
Abstract
OBJECTIVE In an effort to minimize the effect of extracorporeal circulation (ECC), mini-bypass is gaining clinical acceptance in routine coronary artery bypass grafting (CABG). These small circuits target combine the clinical advantages of reduced prime, 100% bio-coating and suction blood separation. We demonstrate that the use of mini-bypass in routine CABG reduces homologous blood product use and postoperative bleeding. Our goal was to also demonstrate that these small systems are effective in gaseous microemboli (GME) management as compared to a conventional extracorporeal system. METHODS Prospective, randomized study comparing 30 mini-bypass (Dideco ECC.O) to 30 conventional systems (n=30, Dideco 903 Avant). Study included CABG cases only, independent of preoperative coagulative status; clinic ethical committee approval and informed patient consent was obtained before initiating study. RESULTS There were no statistical differences in terms of patient demographics. Statistically significant differences were seen in transfusion frequency (27% of the study group vs 43% in the control group, p=0.05), transfused volume (133.3+/-244.5 ml vs 325+/-483.1 ml, p<0.05), fresh frozen plasma (0 unit vs 3 units, p<0.001), postoperative bleeding (301.8+/-531.9 ml vs 785.5+/-1000.4 ml, p<0.05) and GME activity post-arterial filter (0.14 microl vs 5.32 microl, p<0.05). CONCLUSIONS The adoption of mini-bypass significantly potentially reduces hemodilution, donor blood usage, postoperative bleeding and exposure to GME in routine CABG patients as compared to the use of conventional extracorporeal circulation circuits.
Collapse
|
98
|
Stegmayr CJ, Jonsson P, Forsberg U, Stegmayr BG. Development of Air Micro Bubbles in the Venous Outlet Line: An In Vitro Analysis of Various Air Traps Used for Hemodialysis. Artif Organs 2007; 31:483-8. [PMID: 17537063 DOI: 10.1111/j.1525-1594.2007.00411.x] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Venous air traps were tested in vitro with respect to presence of micro bubbles. Three types of venous air traps were measured (Bioline, Bioline GmbH, Luckenwalde, Germany; Gambro, Gambro AB, Lund, Sweden; Fresenius M.C., Fresenius Medical Care AG & Co. KGaA, Bad Homburg, Germany). Measurements (n = 10) were taken for each air trap, fluid flow (50-600 mL/min), and fluid level (high/low). A 1.5-MHz ultrasound probe was used with an analysis device. The probe was mounted on the outlet line downstream of the venous air trap. A semisynthetic fluid was used to resemble blood viscosity. Occurrences of micro bubbles, without inducing an alarm of the dialysis device, were detected in almost all measurements. The amount of bubbles increased with increasing flow. There were more bubbles with low fluid level compared with high level. The Bioline tubing released the least bubbles in high fluid level. At low level, the Gambro tubing showed the least bubbles at flows 50-400 mL/min, and the Fresenius M.C. tubing showed the least bubbles at flows 400-600 mL/min. High fluid level in the air trap reduced generation of micro bubbles compared to low level, as did lower fluid flow versus high flow. The design of the air trap was also of importance.
Collapse
|
99
|
Møllerløkken A, Gutvik C, Berge VJ, Jørgensen A, Løset A, Brubakk AO. Recompression during decompression and effects on bubble formation in the pig. AVIATION, SPACE, AND ENVIRONMENTAL MEDICINE 2007; 78:557-60. [PMID: 17571654] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/15/2023]
Abstract
INTRODUCTION There is a relationship between gas bubble formation in the vascular system and serious decompression sickness. Hence, control of the formation of vascular bubbles should allow safer decompression procedures. METHODS There were 12 pigs that were randomly divided into an experimental group (EXP) and a control group (CTR) of 6 animals each. The pigs were compressed to 500 kPa (5 ATA) in a dry hyperbaric chamber and held for 90 min bottom time breathing air. CTR animals were decompressed according to a modified USN dive profile requiring four stops. EXP followed the same profile except that a 5-min recompression of 50 kPa (0.5 ATA) was added at the end of each of the last three decompression stops before ascending to the next stop depth. RESULTS All CTR animals developed bubbles, compared with only one animal in EXP. The number of bubbles detected during and after the dive was 0.02 +/- 0.02 bubbles x cm(-2) in CTR, while the number of bubbles detected in EXP were 0.0009 +/- 0.005 bubbles x cm(-2); the difference was highly significant. CONCLUSION By brief recompression during late decompression stops, the amount of bubbles was reduced. Our findings give further support for a gas phase model of decompression.
Collapse
|
100
|
Evans LA, Young PJ. Preventing iatrogenic air embolism in the intensive care unit. MEDICAL DEVICE TECHNOLOGY 2007; 18:36-7. [PMID: 17585720] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/15/2023]
Abstract
Air embolism is a potentially fatal consequence of incorrect connection of endotracheal tube cuff inflator devices. Currently, air lines from these devices can be connected to indwelling cannulae without impediment. This possibility can be eliminated with a simple modification of the air line, as described here.
Collapse
|