26
|
Zahid OK, Zhao BS, He C, Hall AR. Quantifying mammalian genomic DNA hydroxymethylcytosine content using solid-state nanopores. Sci Rep 2016; 6:29565. [PMID: 27383905 PMCID: PMC4935868 DOI: 10.1038/srep29565] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2016] [Accepted: 06/17/2016] [Indexed: 12/12/2022] Open
Abstract
5-hydroxymethylcytosine (5 hmC), the oxidized form of 5-methylcytosine (5 mC), is a base modification with emerging importance in biology and disease. However, like most epigenetic elements, it is transparent to many conventional genetic techniques and is thus challenging to probe. Here, we report a rapid solid-state nanopore assay that is capable of resolving 5 hmC with high specificity and sensitivity and demonstrate its utility in assessing global modification abundance in genomic DNA.
Collapse
|
27
|
Wen N, Zhao Z, Fan B, Chen D, Men D, Wang J, Chen J. Development of Droplet Microfluidics Enabling High-Throughput Single-Cell Analysis. Molecules 2016; 21:E881. [PMID: 27399651 PMCID: PMC6272933 DOI: 10.3390/molecules21070881] [Citation(s) in RCA: 54] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2016] [Revised: 06/27/2016] [Accepted: 06/28/2016] [Indexed: 12/20/2022] Open
Abstract
This article reviews recent developments in droplet microfluidics enabling high-throughput single-cell analysis. Five key aspects in this field are included in this review: (1) prototype demonstration of single-cell encapsulation in microfluidic droplets; (2) technical improvements of single-cell encapsulation in microfluidic droplets; (3) microfluidic droplets enabling single-cell proteomic analysis; (4) microfluidic droplets enabling single-cell genomic analysis; and (5) integrated microfluidic droplet systems enabling single-cell screening. We examine the advantages and limitations of each technique and discuss future research opportunities by focusing on key performances of throughput, multifunctionality, and absolute quantification.
Collapse
|
28
|
Koshiba S. [Jananese Multi Omics Reference Panel]. SEIKAGAKU. THE JOURNAL OF JAPANESE BIOCHEMICAL SOCIETY 2016; 88:25-30. [PMID: 27025004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
|
29
|
Biteen JS, Blainey PC, Cardon ZG, Chun M, Church GM, Dorrestein PC, Fraser SE, Gilbert JA, Jansson JK, Knight R, Miller JF, Ozcan A, Prather KA, Quake SR, Ruby EG, Silver PA, Taha S, van den Engh G, Weiss PS, Wong GCL, Wright AT, Young TD. Tools for the Microbiome: Nano and Beyond. ACS NANO 2016; 10:6-37. [PMID: 26695070 DOI: 10.1021/acsnano.5b07826] [Citation(s) in RCA: 94] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
The microbiome presents great opportunities for understanding and improving the world around us and elucidating the interactions that compose it. The microbiome also poses tremendous challenges for mapping and manipulating the entangled networks of interactions among myriad diverse organisms. Here, we describe the opportunities, technical needs, and potential approaches to address these challenges, based on recent and upcoming advances in measurement and control at the nanoscale and beyond. These technical needs will provide the basis for advancing the largely descriptive studies of the microbiome to the theoretical and mechanistic understandings that will underpin the discipline of microbiome engineering. We anticipate that the new tools and methods developed will also be more broadly useful in environmental monitoring, medicine, forensics, and other areas.
Collapse
|
30
|
Chaitanya L, Ralf A, van Oven M, Kupiec T, Chang J, Lagacé R, Kayser M. Simultaneous Whole Mitochondrial Genome Sequencing with Short Overlapping Amplicons Suitable for Degraded DNA Using the Ion Torrent Personal Genome Machine. Hum Mutat 2015; 36:1236-47. [PMID: 26387877 PMCID: PMC5057296 DOI: 10.1002/humu.22905] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2015] [Accepted: 09/01/2015] [Indexed: 11/13/2022]
Abstract
Whole mitochondrial (mt) genome analysis enables a considerable increase in analysis throughput, and improves the discriminatory power to the maximum possible phylogenetic resolution. Most established protocols on the different massively parallel sequencing (MPS) platforms, however, invariably involve the PCR amplification of large fragments, typically several kilobases in size, which may fail due to mtDNA fragmentation in the available degraded materials. We introduce a MPS tiling approach for simultaneous whole human mt genome sequencing using 161 short overlapping amplicons (average 200 bp) with the Ion Torrent Personal Genome Machine. We illustrate the performance of this new method by sequencing 20 DNA samples belonging to different worldwide mtDNA haplogroups. Additional quality control, particularly regarding the potential detection of nuclear insertions of mtDNA (NUMTs), was performed by comparative MPS analysis using the conventional long-range amplification method. Preliminary sensitivity testing revealed that detailed haplogroup inference was feasible with 100 pg genomic input DNA. Complete mt genome coverage was achieved from DNA samples experimentally degraded down to genomic fragment sizes of about 220 bp, and up to 90% coverage from naturally degraded samples. Overall, we introduce a new approach for whole mt genome MPS analysis from degraded and nondegraded materials relevant to resolve and infer maternal genetic ancestry at complete resolution in anthropological, evolutionary, medical, and forensic applications.
Collapse
|
31
|
Gomez-Pulido JA, Schmidt B, Feng WC. Accelerating Bioinformatics Applications via Emerging Parallel Computing Systems. IEEE/ACM TRANSACTIONS ON COMPUTATIONAL BIOLOGY AND BIOINFORMATICS 2015; 12:971-972. [PMID: 26734702 DOI: 10.1109/tcbb.2015.2457736] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
|
32
|
You Q, Zhang L, Yi X, Zhang Z, Xu W, Su Z. SIFGD: Setaria italica Functional Genomics Database. MOLECULAR PLANT 2015; 8:967-70. [PMID: 25676456 DOI: 10.1016/j.molp.2015.02.001] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/29/2014] [Revised: 12/26/2014] [Accepted: 02/01/2015] [Indexed: 05/12/2023]
|
33
|
Colmsee C, Beier S, Himmelbach A, Schmutzer T, Stein N, Scholz U, Mascher M. BARLEX - the Barley Draft Genome Explorer. MOLECULAR PLANT 2015; 8:964-6. [PMID: 25804976 DOI: 10.1016/j.molp.2015.03.009] [Citation(s) in RCA: 73] [Impact Index Per Article: 8.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/06/2014] [Revised: 02/11/2015] [Accepted: 03/18/2015] [Indexed: 05/03/2023]
|
34
|
Krouk G, Carré C, Fizames C, Gojon A, Ruffel S, Lacombe B. GeneCloud Reveals Semantic Enrichment in Lists of Gene Descriptions. MOLECULAR PLANT 2015; 8:971-973. [PMID: 25707756 DOI: 10.1016/j.molp.2015.02.005] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/22/2014] [Revised: 01/30/2015] [Accepted: 02/09/2015] [Indexed: 06/04/2023]
|
35
|
|
36
|
Fernandez-Pozo N, Rosli HG, Martin GB, Mueller LA. The SGN VIGS tool: user-friendly software to design virus-induced gene silencing (VIGS) constructs for functional genomics. MOLECULAR PLANT 2015; 8:486-8. [PMID: 25667001 DOI: 10.1016/j.molp.2014.11.024] [Citation(s) in RCA: 102] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/09/2014] [Revised: 11/21/2014] [Accepted: 11/30/2014] [Indexed: 05/13/2023]
|
37
|
Chen P, Wang C, Li X, Zhou X. Accelerating the Next Generation Long Read Mapping with the FPGA-Based System. IEEE/ACM TRANSACTIONS ON COMPUTATIONAL BIOLOGY AND BIOINFORMATICS 2014; 11:840-852. [PMID: 26356857 DOI: 10.1109/tcbb.2014.2326876] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
To compare the newly determined sequences against the subject sequences stored in the databases is a critical job in the bioinformatics. Fortunately, recent survey reports that the state-of-the-art aligners are already fast enough to handle the ultra amount of short sequence reads in the reasonable time. However, for aligning the long sequence reads (>400 bp) generated by the next generation sequencing (NGS) technology, it is still quite inefficient with present aligners. Furthermore, the challenge becomes more and more serious as the lengths and the amounts of the sequence reads are both keeping increasing with the improvement of the sequencing technology. Thus, it is extremely urgent for the researchers to enhance the performance of the long read alignment. In this paper, we propose a novel FPGA-based system to improve the efficiency of the long read mapping. Compared to the state-of-the-art long read aligner BWA-SW, our accelerating platform could achieve a high performance with almost the same sensitivity. Experiments demonstrate that, for reads with lengths ranging from 512 up to 4,096 base pairs, the described system obtains a 10x -48x speedup for the bottleneck of the software. As to the whole mapping procedure, the FPGA-based platform could achieve a 1.8x -3:3x speedup versus the BWA-SW aligner, reducing the alignment cycles from weeks to days.
Collapse
|
38
|
Motoike IN, Matsumoto M, Danjoh I, Katsuoka F, Kojima K, Nariai N, Sato Y, Yamaguchi-Kabata Y, Ito S, Kudo H, Nishijima I, Nishikawa S, Pan X, Saito R, Saito S, Saito T, Shirota M, Tsuda K, Yokozawa J, Igarashi K, Minegishi N, Tanabe O, Fuse N, Nagasaki M, Kinoshita K, Yasuda J, Yamamoto M. Validation of multiple single nucleotide variation calls by additional exome analysis with a semiconductor sequencer to supplement data of whole-genome sequencing of a human population. BMC Genomics 2014; 15:673. [PMID: 25109789 PMCID: PMC4138778 DOI: 10.1186/1471-2164-15-673] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2013] [Accepted: 08/01/2014] [Indexed: 12/16/2022] Open
Abstract
BACKGROUND Validation of single nucleotide variations in whole-genome sequencing is critical for studying disease-related variations in large populations. A combination of different types of next-generation sequencers for analyzing individual genomes may be an efficient means of validating multiple single nucleotide variations calls simultaneously. RESULTS Here, we analyzed 12 independent Japanese genomes using two next-generation sequencing platforms: the Illumina HiSeq 2500 platform for whole-genome sequencing (average depth 32.4×), and the Ion Proton semiconductor sequencer for whole exome sequencing (average depth 109×). Single nucleotide polymorphism (SNP) calls based on the Illumina Human Omni 2.5-8 SNP chip data were used as the reference. We compared the variant calls for the 12 samples, and found that the concordance between the two next-generation sequencing platforms varied between 83% and 97%. CONCLUSIONS Our results show the versatility and usefulness of the combination of exome sequencing with whole-genome sequencing in studies of human population genetics and demonstrate that combining data from multiple sequencing platforms is an efficient approach to validate and supplement SNP calls.
Collapse
|
39
|
Stunnenberg HG, Hubner NC. Genomics meets proteomics: identifying the culprits in disease. Hum Genet 2014; 133:689-700. [PMID: 24135908 PMCID: PMC4021166 DOI: 10.1007/s00439-013-1376-2] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2013] [Accepted: 10/01/2013] [Indexed: 12/20/2022]
Abstract
Genome-wide association studies (GWAS) revealed genomic risk loci that potentially have an impact on disease and phenotypic traits. This extensive resource holds great promise in providing novel directions for personalized medicine, including disease risk prediction, prevention and targeted medication. One of the major challenges that researchers face on the path between the initial identification of an association and precision treatment of patients is the comprehension of the biological mechanisms that underlie these associations. Currently, the focus to solve these questions lies on the integrative analysis of system-wide data on global genome variation, gene expression, transcription factor binding, epigenetic profiles and chromatin conformation. The generation of this data mainly relies on next-generation sequencing. However, due to multiple recent developments, mass spectrometry-based proteomics now offers additional, by the GWAS field so far hardly recognized possibilities for the identification of functional genome variants and, in particular, for the identification and characterization of (differentially) bound protein complexes as well as physiological target genes. In this review, we introduce these proteomics advances and suggest how they might be integrated in post-GWAS workflows. We argue that the combination of highly complementary techniques is powerful and can provide an unbiased, detailed picture of GWAS loci and their mechanistic involvement in disease.
Collapse
|
40
|
McBride D. Smartphone gamers decode six months of cancer DNA data in one month. ONS CONNECT 2014; 29:40. [PMID: 24961043] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
|
41
|
Cheung HH, Claus J, Singh S, Sastry C, Rennert OM, Chan WY, Lee TL. Mapping genomic features of tiling microarray data by TileMapper. Methods Mol Biol 2014; 1067:225-33. [PMID: 23975795 DOI: 10.1007/978-1-62703-607-8_14] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/20/2023]
Abstract
The recent revolution of genomics techniques has allowed the detection of various sequence features and biological variations on whole-genome scale. However, these high-resolution data present significant challenges for experimental biologists to understand and analyze. The conventional way is to use genome browsers to locate and visualize regions of interest. But it lacks user-friendly data mining functionality. Here we present a protocol that allows rapid annotation of genomic coordinate data by using TileMapper. Interesting biological annotations from large-scale genomic data, such as transcriptome analysis, chromatin immunoprecipitation on chip, or methyl-DNA immunoprecipitation (MeDIP) studies generated from the tiling microarrays and other platforms, could be analyzed without requiring computational skills. The outputs are saved in tabulated format, which permit flexible and simple processing in spreadsheet software, or to be exported to other pipelines for subsequent analysis.
Collapse
|
42
|
|
43
|
Glorikian H. Genomics: gearing up for the laboratory of the future. MLO: MEDICAL LABORATORY OBSERVER 2014; 46:8-11. [PMID: 24672844] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
|
44
|
Ng ACH, Baird SD, Screaton RA. High-content functional genomic screening to identify novel regulators of the PINK1-Parkin pathway. Methods Enzymol 2014; 547:1-20. [PMID: 25416349 DOI: 10.1016/b978-0-12-801415-8.00001-1] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
PINK1/PARK6 and Parkin/PARK2 are amongst the most commonly mutated genes associated with recessive forms of familial Parkinson's disease. Recent evidence indicates that the proteins they encode, PINK1 and Parkin, function in the same pathway to mediate the selective autophagic clearance of dysfunctional mitochondria. Upon mitochondrial damage, PINK1 is stabilized on the outer mitochondrial membrane where it phosphorylates ubiquitin, generating a signal for the recruitment and activation of Parkin. However, key mechanistic questions still exist regarding Parkin recruitment, including whether or not other factors are required for the PINK1 and Parkin pathway. We describe a method below using high-throughput RNA interference technology to interrogate the genome for novel components of the PINK1 and Parkin pathway.
Collapse
|
45
|
De Coninck A, Fostier J, Maenhout S, De Baets B. A high performance computing approach for genomic prediction. COMMUNICATIONS IN AGRICULTURAL AND APPLIED BIOLOGICAL SCIENCES 2014; 79:115-119. [PMID: 25864324] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
|
46
|
Kim HS, Sung JS, Yang SJ, Kwon NJ, Jin L, Kim ST, Park KH, Shin SW, Kim HK, Kang JH, Kim JO, Park JY, Choi JE, Yoon H, Park CK, Yang KS, Seo JS, Kim YH. Predictive efficacy of low burden EGFR mutation detected by next-generation sequencing on response to EGFR tyrosine kinase inhibitors in non-small-cell lung carcinoma. PLoS One 2013; 8:e81975. [PMID: 24376508 PMCID: PMC3869671 DOI: 10.1371/journal.pone.0081975] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2013] [Accepted: 10/18/2013] [Indexed: 11/21/2022] Open
Abstract
Direct sequencing remains the most widely used method for the detection of epidermal growth factor receptor (EGFR) mutations in lung cancer; however, its relatively low sensitivity limits its clinical use. The objective of this study was to investigate the sensitivity of detecting an epidermal growth factor receptor (EGFR) mutation from peptide nucleic acid-locked nucleic acid polymerase chain reaction (PNA-LNA PCR) clamp and Ion Torrent Personal Genome Machine (PGM) techniques compared to that by direct sequencing. Furthermore, the predictive efficacy of EGFR mutations detected by PNA-LNA PCR clamp was evaluated. EGFR mutational status was assessed by direct sequencing, PNA-LNA PCR clamp, and Ion Torrent PGM in 57 patients with non-small cell lung cancer (NSCLC). We evaluated the predictive efficacy of PNA-LNA PCR clamp on the EGFR-TKI treatment in 36 patients with advanced NSCLC retrospectively. Compared to direct sequencing (16/57, 28.1%), PNA-LNA PCR clamp (27/57, 47.4%) and Ion Torrent PGM (26/57, 45.6%) detected more EGFR mutations. EGFR mutant patients had significantly longer progressive free survival (14.31 vs. 21.61 months, P = 0.003) than that of EGFR wild patients when tested with PNA-LNA PCR clamp. However, no difference in response rate to EGFR TKIs (75.0% vs. 82.4%, P = 0.195) or overall survival (34.39 vs. 44.10 months, P = 0.422) was observed between the EGFR mutations by direct sequencing or PNA-LNA PCR clamp. Our results demonstrate firstly that patients with EGFR mutations were detected more frequently by PNA-LNA PCR clamp and Ion Torrent PGM than those by direct sequencing. EGFR mutations detected by PNA-LNA PCR clamp may be as a predicative factor for EGFR TKI response in patients with NSCLC.
Collapse
|
47
|
Esfandyarpour R, Esfandyarpour H, Harris JS, Davis RW. Simulation and fabrication of a new novel 3D injectable biosensor for high throughput genomics and proteomics in a lab-on-a-chip device. NANOTECHNOLOGY 2013; 24:465301. [PMID: 24149048 PMCID: PMC3878440 DOI: 10.1088/0957-4484/24/46/465301] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
Biosensors are used for the detection of biochemical molecules such as proteins and nucleic acids. Traditional techniques, such as enzyme-linked immuno-sorbent assay (ELISA), are sensitive but require several hours to yield a result and usually require the attachment of a fluorophore molecule to the target molecule. Micromachined biosensors that employ electrical detection are now being developed. Here we describe one such device, which is ultrasensitive, real-time, label free and localized. It is called the nanoneedle biosensor and shows promise to overcome some of the current limitations of biosensors. The key element of this device is a 10 nm wide annular gap at the end of the needle, which is the sensitive part of the sensor. The total diameter of the sensor is about 100 nm. Any change in the population of molecules in this gap results in a change of impedance across the gap. Single molecule detection should be possible because the sensory part of the sensor is in the range of bio-molecules of interest. To increase throughput we can flow the solution containing the target molecules over an array of such structures, each with its own integrated read-out circuitry to allow 'real-time' detection (i.e. several minutes) of label free molecules without sacrificing sensitivity. To fabricate the arrays we used electron beam lithography together with associated pattern transfer techniques. Preliminary measurements on individual needle structures in water are consistent with the design. Since the proposed sensor has a rigid nano-structure, this technology, once fully developed, could ultimately be used to directly monitor protein quantities within a single living cell, an application that would have significant utility for drug screening and studying various intracellular signaling pathways.
Collapse
|
48
|
Myers FB, Henrikson RH, Bone J, Lee LP. A handheld point-of-care genomic diagnostic system. PLoS One 2013; 8:e70266. [PMID: 23936402 PMCID: PMC3731356 DOI: 10.1371/journal.pone.0070266] [Citation(s) in RCA: 70] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/25/2012] [Accepted: 06/18/2013] [Indexed: 11/18/2022] Open
Abstract
The rapid detection and identification of infectious disease pathogens is a critical need for healthcare in both developed and developing countries. As we gain more insight into the genomic basis of pathogen infectivity and drug resistance, point-of-care nucleic acid testing will likely become an important tool for global health. In this paper, we present an inexpensive, handheld, battery-powered instrument designed to enable pathogen genotyping in the developing world. Our Microfluidic Biomolecular Amplification Reader (µBAR) represents the convergence of molecular biology, microfluidics, optics, and electronics technology. The µBAR is capable of carrying out isothermal nucleic acid amplification assays with real-time fluorescence readout at a fraction of the cost of conventional benchtop thermocyclers. Additionally, the µBAR features cell phone data connectivity and GPS sample geotagging which can enable epidemiological surveying and remote healthcare delivery. The µBAR controls assay temperature through an integrated resistive heater and monitors real-time fluorescence signals from 60 individual reaction chambers using LEDs and phototransistors. Assays are carried out on PDMS disposable microfluidic cartridges which require no external power for sample loading. We characterize the fluorescence detection limits, heater uniformity, and battery life of the instrument. As a proof-of-principle, we demonstrate the detection of the HIV-1 integrase gene with the µBAR using the Loop-Mediated Isothermal Amplification (LAMP) assay. Although we focus on the detection of purified DNA here, LAMP has previously been demonstrated with a range of clinical samples, and our eventual goal is to develop a microfluidic device which includes on-chip sample preparation from raw samples. The µBAR is based entirely around open source hardware and software, and in the accompanying online supplement we present a full set of schematics, bill of materials, PCB layouts, CAD drawings, and source code for the µBAR instrument with the goal of spurring further innovation toward low-cost genetic diagnostics.
Collapse
|
49
|
Bootman JL. The convergence of new technology with the delivery of health care services. AMERICAN JOURNAL OF PHARMACEUTICAL EDUCATION 2013; 77:1. [PMID: 23460753 PMCID: PMC3578322 DOI: 10.5688/ajpe7711] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/03/2012] [Accepted: 12/09/2012] [Indexed: 05/16/2023]
|
50
|
Abstract
Automated DNA sequencing instruments embody an elegant interplay among chemistry, engineering, software, and molecular biology and have built upon Sanger's founding discovery of dideoxynucleotide sequencing to perform once-unfathomable tasks. Combined with innovative physical mapping approaches that helped to establish long-range relationships between cloned stretches of genomic DNA, fluorescent DNA sequencers produced reference genome sequences for model organisms and for the reference human genome. New types of sequencing instruments that permit amazing acceleration of data-collection rates for DNA sequencing have been developed. The ability to generate genome-scale data sets is now transforming the nature of biological inquiry. Here, I provide an historical perspective of the field, focusing on the fundamental developments that predated the advent of next-generation sequencing instruments and providing information about how these instruments work, their application to biological research, and the newest types of sequencers that can extract data from single DNA molecules.
Collapse
|