26
|
Potter S, Graves J, Drach B, Leahy T, Hammel C, Feng Y, Baker A, Sacks MS. A Novel Small-Specimen Planar Biaxial Testing System With Full In-Plane Deformation Control. J Biomech Eng 2018; 140:2666965. [PMID: 29247251 PMCID: PMC5816250 DOI: 10.1115/1.4038779] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2017] [Revised: 12/11/2017] [Indexed: 01/12/2023]
Abstract
Simulations of soft tissues require accurate and robust constitutive models, whose form is derived from carefully designed experimental studies. For such investigations of membranes or thin specimens, planar biaxial systems have been used extensively. Yet, all such systems remain limited in their ability to: (1) fully prescribe in-plane deformation gradient tensor F2D, (2) ensure homogeneity of the applied deformation, and (3) be able to accommodate sufficiently small specimens to ensure a reasonable degree of material homogeneity. To address these issues, we have developed a novel planar biaxial testing device that overcomes these difficulties and is capable of full control of the in-plane deformation gradient tensor F2D and of testing specimens as small as ∼4 mm × ∼4 mm. Individual actuation of the specimen attachment points, combined with a robust real-time feedback control, enabled the device to enforce any arbitrary F2D with a high degree of accuracy and homogeneity. Results from extensive device validation trials and example tissues illustrated the ability of the device to perform as designed and gather data needed for developing and validating constitutive models. Examples included the murine aortic tissues, allowing for investigators to take advantage of the genetic manipulation of murine disease models. These capabilities highlight the potential of the device to serve as a platform for informing and verifying the results of inverse models and for conducting robust, controlled investigation into the biomechanics of very local behaviors of soft tissues and membrane biomaterials.
Collapse
|
27
|
Paris-Garcia F, Barroso A, Paris F. A study of the reproducibility and reliability of the musculo-articular stiffness of the ankle joint. J Mech Behav Biomed Mater 2018; 82:145-153. [PMID: 29601986 DOI: 10.1016/j.jmbbm.2018.03.017] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2017] [Revised: 03/05/2018] [Accepted: 03/14/2018] [Indexed: 11/18/2022]
Abstract
The objective of this work was to evaluate the reproducibility, reliability and usefulness of the musculo-articular stiffness (MAS) of the ankle joint, measuring it by the free vibration technique. Seventeen (nine males and eight females) healthy university students were included in the study. Force (f), MAS (k) and unitary MAS (ku) (defined as the ratio between the value of stiffness k obtained in the test (absolute terms) and the value of force (f)) were obtained. A test-retest protocol was designed and performed on the same day to determine the short-term reproducibility of f, k and ku. Short-term reproducibility of k and ku on 1 day in absolute terms (< 7% Coefficient of Variation (CV)) and relative reproducibility (Intraclass Correlation Coefficient (ICC) and Pearson ≥ 0.97) for both feet were obtained. The reliability of k and ku in absolute terms (< 9% CV) and in relative terms (ICC and Pearson ≥0.93) based on repeating the protocol for 1 week was analysed for both feet. To analyse the usefulness, the Effect Size (ES) ratio = "Trivial" for all variables (for 1 day and 1 week) and the Smallest Worthwhile Change (SWC) ratio (Typical Error (TE)< SWC) = "GOOD" for k and ku (1 day and 1 week) were considered. The Minimal Difference needed to be considered "real" (MD) for ku ≅ 3.5% (1 day); ku≅ 8.5% (1 week) (p < 0.05) was obtained. The statistical analysis carried out displayed the high reproducibility, reliability and usefulness of the MAS test, which was more consistent with ku than k. Therefore, the unitary stiffness (ku) proven to be representative of the mechanical response of the ankle joint obtained by free vibration techniques, which allows comparison between different subjects.
Collapse
|
28
|
Sakoda S, Nakao N, Watanabe I. The effect of abrading and cutting instruments on machinability of dental ceramics. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2018; 29:34. [PMID: 29549513 DOI: 10.1007/s10856-018-6031-y] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/29/2017] [Accepted: 01/16/2018] [Indexed: 06/08/2023]
Abstract
The aim was to investigate the effect of machining instruments on machinability of dental ceramics. Four dental ceramics, including two zirconia ceramics were machined by three types (SiC, diamond vitrified, and diamond sintered) of wheels with a hand-piece engine and two types (diamond and carbide) of burs with a high-speed air turbine. The machining conditions used were abrading speeds of 10,000 and 15,000 r.p.m. with abrading force of 100 gf for the hand-piece engine, and a pressure of 200 kPa and a cutting force of 80 gf for the air-turbine hand-piece. The machinability efficiency was evaluated by volume losses after machining the ceramics. A high-abrading speed had high-abrading efficiency (high-volume loss) compared to low-abrading speed in all abrading instruments used. The diamond vitrified wheels demonstrated higher volume loss for two zirconia ceramics than those of SiC and diamond sintered wheels. When the high-speed air-turbine instruments were used, the diamond points showed higher volume losses compared to the carbide burs for one ceramic and two zirconia ceramics with high-mechanical properties. The results of this study indicated that the machinability of dental ceramics depends on the mechanical and physical properties of dental ceramics and machining instruments. The abrading wheels show autogenous action of abrasive grains, in which ground abrasive grains drop out from the binder during abrasion, then the binder follow to wear out, subsequently new abrasive grains come out onto the instrument surface (autogenous action) and increase the grinding amount (volume loss) of grinding materials.
Collapse
|
29
|
Palagummi SV, Landis FA, Chiang MYM. Real-time synchronous measurement of curing characteristics and polymerization stress in bone cements with a cantilever-beam based instrument. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2018; 89:035102. [PMID: 29604748 PMCID: PMC5834317 DOI: 10.1063/1.5025476] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/30/2017] [Accepted: 02/07/2018] [Indexed: 06/08/2023]
Abstract
An instrumentation capable of simultaneously determining degree of conversion (DC), polymerization stress (PS), and polymerization exotherm (PE) in real time was introduced to self-curing bone cements. This comprises the combination of an in situ high-speed near-infrared spectrometer, a cantilever-beam instrument with compliance-variable feature, and a microprobe thermocouple. Two polymethylmethacrylate-based commercial bone cements, containing essentially the same raw materials but differ in their viscosity for orthopedic applications, were used to demonstrate the applicability of the instrumentation. The results show that for both the cements studied the final DC was marginally different, the final PS was different at the low compliance, the peak of the PE was similar, and their polymerization rates were significantly different. Systematic variation of instrumental compliance for testing reveals differences in the characteristics of PS profiles of both the cements. This emphasizes the importance of instrumental compliance in obtaining an accurate understanding of PS evaluation. Finally, the key advantage for the simultaneous measurements is that these polymerization properties can be correlated directly, thus providing higher measurement confidence and enables a more in-depth understanding of the network formation process.
Collapse
|
30
|
Irmscher C, Woschke E, May E, Daniel C. Design, optimisation and testing of a compact, inexpensive elastic element for series elastic actuators. Med Eng Phys 2018; 52:84-89. [PMID: 29373234 DOI: 10.1016/j.medengphy.2017.12.004] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2016] [Revised: 11/21/2017] [Accepted: 12/24/2017] [Indexed: 11/18/2022]
Abstract
This paper presents the development of a compact torsion spring for use as an elastic element in a lightweight series elastic actuator for an active orthosis. This orthosis is going to be utilised as an assistive device for motorically impaired stroke-patients. In the design a two-step optimisation strategy was implemented to meet all requirements for the torsion spring. The first step was to identify a promising topology for the element. In the second step, the shape was optimised based on a finite element model using two different optimisation methods in order to minimise the von Mises equivalent stresses. Four promising variants of the identified topology were extracted from these calculations, one of which was then chosen as the final design. A prototype was manufactured by a laser cutting process, which is a new procedure in the context of elastic elements for series elastic actuators. The calculation results were validated successfully by measurement of the spring properties of this prototype.
Collapse
|
31
|
Ivanov IE, Lebel P, Oberstrass FC, Starr CH, Parente AC, Ierokomos A, Bryant Z. Multimodal Measurements of Single-Molecule Dynamics Using FluoRBT. Biophys J 2018; 114:278-282. [PMID: 29248150 PMCID: PMC5984952 DOI: 10.1016/j.bpj.2017.11.017] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2017] [Revised: 10/15/2017] [Accepted: 11/08/2017] [Indexed: 11/21/2022] Open
Abstract
Single-molecule methods provide direct measurements of macromolecular dynamics, but are limited by the number of degrees of freedom that can be followed at one time. High-resolution rotor bead tracking (RBT) measures DNA torque, twist, and extension, and can be used to characterize the structural dynamics of DNA and diverse nucleoprotein complexes. Here, we extend RBT to enable simultaneous monitoring of additional degrees of freedom. Fluorescence-RBT (FluoRBT) combines magnetic tweezers, infrared evanescent scattering, and single-molecule FRET imaging, providing real-time multiparameter measurements of complex molecular processes. We demonstrate the capabilities of FluoRBT by conducting simultaneous measurements of extension and FRET during opening and closing of a DNA hairpin under tension, and by observing simultaneous changes in FRET and torque during a transition between right-handed B-form and left-handed Z-form DNA under controlled supercoiling. We discover unanticipated continuous changes in FRET with applied torque, and also show how FluoRBT can facilitate high-resolution FRET measurements of molecular states, by using a mechanical signal as an independent temporal reference for aligning and averaging noisy fluorescence data. By combining mechanical measurements of global DNA deformations with FRET measurements of local conformational changes, FluoRBT will enable multidimensional investigations of systems ranging from DNA structures to large macromolecular machines.
Collapse
|
32
|
Evin M, Magne J, Grieve SM, Rieu R, Pibarot P. Characterization of Effective Orifice Areas of Mitral Prosthetic Heart Valves: An In-Vitro Study. THE JOURNAL OF HEART VALVE DISEASE 2017; 26:677-687. [PMID: 30207118] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
BACKGROUND Reference values of hemodynamic parameters for the assessment of prosthetic heart valves are necessary, and ideally need to be provided by entities independent of the valve manufacturers. Thus, the study aim was to provide, in vitro, normal reference values of the effective orifice area (EOA) for different models and sizes of mitral prosthetic valve, and to assess the determinants of EOA and mean transvalvular pressure gradient (mTPG). METHODS Four models of mechanical prostheses were tested (one mono-leaflet, three bi-leaflet) and four models of bioprostheses (two bovine pericardial, two porcine) on a double-activation pulsed duplicator that was specifically designed and optimized for assessing the hemodynamic performance of mitral prosthetic valves. The hemodynamic conditions were standardized and included for bioprostheses: two mitral flow volumes, three mean aortic pressures, two heart rates, and three E/A ratios. The EOAs were measured with Doppler echocardiography, using the same method (continuity equation) as was used in the clinical setting. Overestimation in term of EOA was defined according to guidelines as >0.25 cm2. RESULTS EOA reference values were recorded. For mono-leaflet prostheses (Medtronic Hall 7700, size 25 to 31 mm) 2.29 and 3.49; for bi-leaflet prostheses (St. Jude Medical Master and Master HP, sizes 25 to 33 mm and On-X valve, sizes 27-29 mm) 1.34 and 4.74 cm2; for porcine bioprostheses (Medtronic Mosaic CINCH, sizes 25 to 31 mm and St. Jude Epic 100, sizes 25 to 33 mm) 1.35 and 3.56 cm2; for bovine pericardial bioprosthetic valves (Edwards Perimount 6900P and Magna Ease 7300, sizes 25 to 33 mm) 1.67 and 2.36 cm2. There were some discrepancies between the normal reference EOAs measured compared to those provided by the prosthesis manufacturers, or in published reports. The bioprosthetic EOAs were shown to be smaller than the manufacturers' values in 32% of valves (by an average of 0.57 ± 0.28 cm2) versus in 7% of valves when compared to values reported elsewhere (by an average of 0.43 ± 0.17 cm2). The relationship between EOA and internal orifice area (IOA) varied according to the type of prosthesis. The EOA was close to the IOA in mechanical valves (regression slopes 0.87-0.99) but was much smaller than the IOA in bioprosthetic valves (slopes 0.25-0.30). The EOA was influenced by prosthesis diameter, prosthesis stent diameter and height, while the mTPG was influenced by EOA and heart rate. CONCLUSIONS The present study has provided normal reference values of EOAs for several frequently used mitral prostheses. This information may be helpful for identifying and quantifying prosthetic valve dysfunction and prosthesis-patient mismatch.
Collapse
|
33
|
Schmoll M, Unger E, Bijak M, Stoiber M, Lanmüller H, Jarvis JC. A novel miniature in-line load-cell to measure in-situ tensile forces in the tibialis anterior tendon of rats. PLoS One 2017; 12:e0185209. [PMID: 28934327 PMCID: PMC5608493 DOI: 10.1371/journal.pone.0185209] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2017] [Accepted: 09/10/2017] [Indexed: 11/19/2022] Open
Abstract
Direct measurements of muscular forces usually require a substantial rearrangement of the biomechanical system. To circumvent this problem, various indirect techniques have been used in the past. We introduce a novel direct method, using a lightweight (~0.5 g) miniature (3 x 3 x 7 mm) in-line load-cell to measure tension in the tibialis anterior tendon of rats. A linear motor was used to produce force-profiles to assess linearity, step-response, hysteresis and frequency behavior under controlled conditions. Sensor responses to a series of rectangular force-pulses correlated linearly (R2 = 0.999) within the range of 0–20 N. The maximal relative error at full scale (20 N) was 0.07% of the average measured signal. The standard deviation of the mean response to repeated 20 N force pulses was ± 0.04% of the mean response. The step-response of the load-cell showed the behavior of a PD2T2-element in control-engineering terminology. The maximal hysteretic error was 5.4% of the full-scale signal. Sinusoidal signals were attenuated maximally (-4 dB) at 200 Hz, within a measured range of 0.01–200 Hz. When measuring muscular forces this should be of minor concern as the fusion-frequency of muscles is generally much lower. The newly developed load-cell measured tensile forces of up to 20 N, without inelastic deformation of the sensor. It qualifies for various applications in which it is of interest directly to measure forces within a particular tendon causing only minimal disturbance to the biomechanical system.
Collapse
|
34
|
Liu L, Koo Y, Collins B, Xu Z, Sankar J, Yun Y. Biodegradability and platelets adhesion assessment of magnesium-based alloys using a microfluidic system. PLoS One 2017; 12:e0182914. [PMID: 28797069 PMCID: PMC5552284 DOI: 10.1371/journal.pone.0182914] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2017] [Accepted: 07/26/2017] [Indexed: 12/15/2022] Open
Abstract
Magnesium (Mg)-based stents are extensively explored to alleviate atherosclerosis due to their biodegradability and relative hemocompatibility. To ensure the quality, safety and cost-efficacy of bioresorbable scaffolds and full utilization of the material tunability afforded by alloying, it is critical to access degradability and thrombosis potential of Mg-based alloys using improved in vitro models that mimic as closely as possible the in vivo microenvironment. In this study, we investigated biodegradation and initial thrombogenic behavior of Mg-based alloys at the interface between Mg alloys' surface and simulated physiological environment using a microfluidic system. The degradation properties of Mg-based alloys WE43, AZ31, ZWEK-L, and ZWEK-C were evaluated in complete culture medium and their thrombosis potentials in platelet rich plasma, respectively. The results show that 1) physiological shear stress increased the corrosion rate and decreased platelets adhesion rate as compared to static immersion; 2) secondary phases and impurities in material composition induced galvanic corrosion, resulting in higher corrosion resistance and platelet adhesion rate; 3) Mg-based alloys with higher corrosion rate showed higher platelets adhesion rate. We conclude that a microfluidic-based in vitro system allows evaluation of biodegradation behaviors and platelets responses of Mg-based alloys under specific shear stress, and degradability is related to platelets adhesion.
Collapse
|
35
|
Chen X, Peng Y, Peng S, Yao S, Chen C, Xu P. Flow and fracture behavior of aluminum alloy 6082-T6 at different tensile strain rates and triaxialities. PLoS One 2017; 12:e0181983. [PMID: 28759617 PMCID: PMC5536279 DOI: 10.1371/journal.pone.0181983] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2017] [Accepted: 07/10/2017] [Indexed: 11/18/2022] Open
Abstract
This study aims to investigate the flow and fracture behavior of aluminum alloy 6082-T6 (AA6082-T6) at different strain rates and triaxialities. Two groups of Charpy impact tests were carried out to further investigate its dynamic impact fracture property. A series of tensile tests and numerical simulations based on finite element analysis (FEA) were performed. Experimental data on smooth specimens under various strain rates ranging from 0.0001~3400 s-1 shows that AA6082-T6 is rather insensitive to strain rates in general. However, clear rate sensitivity was observed in the range of 0.001~1 s-1 while such a characteristic is counteracted by the adiabatic heating of specimens under high strain rates. A Johnson-Cook constitutive model was proposed based on tensile tests at different strain rates. In this study, the average stress triaxiality and equivalent plastic strain at facture obtained from numerical simulations were used for the calibration of J-C fracture model. Both of the J-C constitutive model and fracture model were employed in numerical simulations and the results was compared with experimental results. The calibrated J-C fracture model exhibits higher accuracy than the J-C fracture model obtained by the common method in predicting the fracture behavior of AA6082-T6. Finally, the Scanning Electron Microscope (SEM) of fractured specimens with different initial stress triaxialities were analyzed. The magnified fractographs indicate that high initial stress triaxiality likely results in dimple fracture.
Collapse
|
36
|
Alexander FA, Wiest J. Automated transepithelial electrical resistance measurements of the EpiDerm reconstructed human epidermis model. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2017; 2016:469-472. [PMID: 28268373 DOI: 10.1109/embc.2016.7590741] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Understanding the effect of exogenous substances on human skin is critical for toxicology assessment. To address this, numerous artificial models of the topmost layer of human skin, so-called reconstructed human epidermis (RhE), have been created in an attempt to produce a clear analogue for testing. Unfortunately, current testing modalities still rely on endpoint assays and are not capable of monitoring time-resolved changes in barrier function without using numerous redundant samples. In this work, a novel, time-resolved approach is realized by monitoring the transepithelial electrical resistance (TEER) of MatTek EpiDerm® reconstructed human epidermis model, utilizing an automated protocol with the Intelligent Mobile Lab for in vitro diagnostics (IMOLA-IVD).
Collapse
|
37
|
Brett SI, Lucien F, Guo C, Williams KC, Kim Y, Durfee PN, Brinker CJ, Chin JI, Yang J, Leong HS. Immunoaffinity based methods are superior to kits for purification of prostate derived extracellular vesicles from plasma samples. Prostate 2017; 77:1335-1343. [PMID: 28762517 DOI: 10.1002/pros.23393] [Citation(s) in RCA: 61] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/10/2017] [Accepted: 07/03/2017] [Indexed: 01/09/2023]
Abstract
BACKGROUND The ability to isolate extracellular vesicles (EVs) such as exosomes or microparticles is an important method that is currently not standardized. While commercially available kits offer purification of EVs from biofluids, such purified EV samples will also contain non-EV entities such as soluble protein and nucleic acids that could confound subsequent experimentation. Ideally, only EVs would be isolated and no soluble protein would be present in the final EV preparation. METHODS We compared commercially available EV isolation kits with immunoaffinity purification techniques and evaluated our final EV preparations using atomic force microscopy (AFM) and nanoscale flow cytometry (NFC). AFM is the only modality capable of detecting distinguishing soluble protein from EVs which is important for downstream proteomics approaches. NFC is the only technique capable of quantitating the proportion of target EVs to non-target EVs in the final EV preparation. RESULTS To determine enrichment of prostate derived EVs relative to non-target MPs, anti-PSMA (Prostate Specific Membrane Antigen) antibodies were used in NFC. Antibody-based immunoaffinity purification generated the highest quality of prostate derived EV preparations due to the lack of protein and RNA present in the samples. All kits produced poor purity EV preparations that failed to deplete the sample of plasma protein. CONCLUSIONS While attractive due to their ease of use, EV purification kits do not provide substantial improvements in isolation of EVs from biofluids such as plasma. Immunoaffinity approaches are more efficient and economical and will also eliminate a significant portion of plasma proteins which is necessary for downstream approaches.
Collapse
|
38
|
Montagner AF, Opdam NJM, De Munck J, Cenci MS, Van Meerbeek B, Huysmans MCDNJ. Bonding Efficacy and Fracture Pattern of Adhesives Submitted to Mechanical Aging with the Rub&Roll Device. THE JOURNAL OF ADHESIVE DENTISTRY 2017; 19:59-68. [PMID: 28195272 DOI: 10.3290/j.jad.a37721] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
PURPOSE To evaluate the effect of water storage and cyclic loading on the microtensile bond strength (μTBS) and fracture pattern of adhesives to dentin. MATERIALS AND METHODS Midcoronal dentin surfaces (n = 36) were prepared and composite restorations were built up using two adhesives (self-etch and etch-and-rinse). The specimens were randomly divided into 3 groups according to the aging conditions (n = 6): 1. CONTROL storage in water for 24 h (CO); 2. water storage: storage in water for 6 months (WS); 3. mechanical loading: 750,000 mechanical cycles (ML) using the Rub&Roll loading device. Specimens were sections into beams and the μTBS was tested. Fracture patterns were analyzed using stereomicroscopy and fractographic analysis was performed using SEM. μTBS data (n = 53-72 specimens) were subjected to two-way ANOVA and Tukey's post-hoc test. The chi-squared test was used to compare the distribution of failure modes (p < 0.05). RESULTS Aging conditions and adhesives significantly affected μTBS (p < 0.01). The CO group showed no difference between materials and had highest μTBS. After WS, the self-etch adhesive showed higher μTBS than did the etchand- rinse adhesive. ML resulted in lower μTBS for both adhesives. Materials (p < 0.01) and aging (p < 0.01) significantly influenced the distribution of failure modes. SEM analysis showed that specimens submitted to WS or ML showed features of degradation and fatigue at the fractured interface, depending on the adhesive. CONCLUSION Mechanical loading had a negative effect on the bonding efficacy of both adhesives and influenced the fracture pattern, with specimens presenting a different fracture surface from that observed in water-stored specimens.
Collapse
|
39
|
Trybuś B, Zieliński A, Beutner R, Seramak T, Scharnweber D. Deposition of phosphate coatings on titanium within scaffold structure. Acta Bioeng Biomech 2017; 19:65-72. [PMID: 28869630] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
PURPOSE Existing knowledge about the appearance, thickness, and chemical composition of phosphate coatings on titanium inside porous structures is insufficient. Such knowledge is important for the design and fabrication of porous implants. METHODS Metallic scaffolds were fabricated by selective laser melting of 316L stainless steel powder. Phosphate coatings were deposited on Ti sensors placed either outside the scaffolds or in the holes in the scaffolds. The electrochemically-assisted cathodic deposition of phosphate coatings was performed under galvanostatic conditions in an electrolyte containing the calcium and phosphate ions. The phosphate deposits were microscopically investigated; this included the performance of mass weight measurements and chemical analyses of the content of Ca2+ and 24 PO ions after the dissolution of deposits. RESULTS The thicknesses of the calcium phosphate coatings were about 140 and 200 nm for isolated titanium sensors and 170 and 300 nm for titanium sensors placed inside pores. Deposition of calcium phosphate occurred inside the pores up to 150 mm below the scaffold surface. The deposits were rich in Ca, with a Ca/P ratio ranging from 2 to 2.5. CONCLUSIONS Calcium phosphate coatings can be successfully deposited on a Ti surface inside a model scaffold. An increase in cathodic current results in an increase in coating thickness. Any decrease in the cathodic current inside the porous structure is slight. The calcium phosphate inside the pores has a much higher Ca/P ratio than that of stoichiometric HAp, likely due to a gradual increase in Ca fraction with distance from the surface.
Collapse
|
40
|
Lughmani WA, Farukh F, Bouazza-Marouf K, Ali H. Drilling resistance: A method to investigate bone quality. Acta Bioeng Biomech 2017; 19:55-62. [PMID: 28552924] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
PURPOSE Bone drilling is a major part of orthopaedic surgery performed during the internal fixation of fractured bones. At present, information related to drilling force, drilling torque, rate of drill-bit penetration and drill-bit rotational speed is not available to orthopaedic surgeons, clinicians and researchers as bone drilling is performed manually. METHODS This study demonstrates that bone drilling force data if recorded in-vivo, during the repair of bone fractures, can provide information about the quality of the bone. To understand the variability and anisotropic behaviour of cortical bone tissue, specimens cut from three anatomic positions of pig and bovine were investigated at the same drilling speed and feed rate. RESULTS The experimental results showed that the drilling force does not only vary from one animal bone to another, but also vary within the same bone due to its changing microstructure. Drilling force does not give a direct indication of bone quality; therefore it has been correlated with screw pull-out force to provide a realistic estimation of the bone quality. A significantly high value of correlation (r2 = 0.93 for pig bones and r2 = 0.88 for bovine bones) between maximum drilling force and normalised screw pull-out strength was found. CONCLUSIONS The results show that drilling data can be used to indicate bone quality during orthopaedic surgery.
Collapse
|
41
|
El Zohairy AA, de Gee AJ, de Jager N, van Ruijven LJ, Feilzer AJ. The Influence of Specimen Attachment and Dimension on Microtensile Strength. J Dent Res 2016; 83:420-4. [PMID: 15111636 DOI: 10.1177/154405910408300513] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
The higher microtensile bond strength values found for specimens with a smaller cross-sectional area are often explained by the lower occurrence of internal defects and surface flaws. We hypothesized that this aberrant behavior is mainly caused by the lateral way of attachment of the specimens to the testing device, which makes the strength dependent on the thickness. This study showed that composite bars of 1×1×10, 1×2×10, and 1×3×10mm attached at their 1-mm-wide side (situation A) fractured at loads of the same magnitude, as a result of which the microtensile strength (μTS), calculated as F/A (force at fracture/cross-sectional area), significantly increased for specimens with decreasing thickness. Attachment at the 1-, 2-, or 3-mm-wide side (situation B) resulted in equal μTS values (P > 0.05). Finite element analysis showed different stress patterns for situation A, but comparable patterns for situation B. Both situations showed the same maximum stress at fracture.
Collapse
|
42
|
Meza D, Abejar L, Rubenstein DA, Yin W. A Shearing-Stretching Device That Can Apply Physiological Fluid Shear Stress and Cyclic Stretch Concurrently to Endothelial Cells. J Biomech Eng 2016; 138:4032550. [PMID: 26810848 DOI: 10.1115/1.4032550] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2015] [Indexed: 11/08/2022]
Abstract
Endothelial cell (EC) morphology and functions can be highly impacted by the mechanical stresses that the cells experience in vivo. In most areas in the vasculature, ECs are continuously exposed to unsteady blood flow-induced shear stress and vasodilation-contraction-induced tensile stress/strain simultaneously. Investigations on how ECs respond to combined shear stress and tensile strain will help us to better understand how an altered mechanical environment affects EC mechanotransduction, dysfunction, and associated cardiovascular disease development. In the present study, a programmable shearing and stretching device that can apply dynamic fluid shear stress and cyclic tensile strain simultaneously to cultured ECs was developed. Flow and stress/strain conditions in the device were simulated using a fluid structure interaction (FSI) model. To characterize the performance of this device and the effect of combined shear stress-tensile strain on EC morphology, human coronary artery ECs (HCAECs) were exposed to concurrent shear stress and cyclic tensile strain in the device. Changes in EC morphology were evaluated through cell elongation, cell alignment, and cell junctional actin accumulation. Results obtained from the numerical simulation indicated that in the "in-plane" area of the device, both fluid shear stress and biaxial tensile strain were uniform. Results obtained from the in vitro experiments demonstrated that shear stress, alone or combined with cyclic tensile strain, induced significant cell elongation. While biaxial tensile strain alone did not induce any appreciable change in EC elongation. Fluid shear stress and cyclic tensile strain had different effects on EC actin filament alignment and accumulation. By combining various fluid shear stress and cyclic tensile strain conditions, this device can provide a physiologically relevant mechanical environment to study EC responses to physiological and pathological mechanical stimulation.
Collapse
|
43
|
Lescun TB, Hoffseth K, Yang HT, Hansma PK, Kopeikin HS, Chandrasekar S. Effect of various testing conditions on results for a handheld reference point indentation instrument in horses. Am J Vet Res 2016; 77:39-49. [PMID: 26709935 DOI: 10.2460/ajvr.77.1.39] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
OBJECTIVE To compare results obtained with a handheld reference point indentation instrument for bone material strength index (BMSi) measurements in the equine third metacarpal bone for various testing conditions. SAMPLE 24 third metacarpal bones. PROCEDURES Third metacarpal bones from both forelimbs of 12 horses were obtained. The dorsal surface of each bone was divided into 6 testing regions. In vivo and ex vivo measurements of BMSi were obtained through the skin and on exposed bone, respectively, to determine effects of each testing condition. Difference plots were used to assess agreement between BMSi obtained for various conditions. Linear regression analysis was used to assess effects of age, sex, and body weight on BMSi. A mixed-model ANOVA was used to assess effects of age, sex, limb, bone region, and testing condition on BMSi values. RESULTS Indentation measurements were performed on standing sedated and recumbent anesthetized horses and on cadaveric bone. Regional differences in BMSi values were detected in adult horses. A significant linear relationship (r(2) = 0.71) was found between body weight and BMSi values. There was no difference between in vivo and ex vivo BMSi values. A small constant bias was detected between BMSi obtained through the skin, compared with values obtained directly on bone. CONCLUSIONS AND CLINICAL RELEVANCE Reference point indentation can be used for in vivo assessment of the resistance of bone tissue to microfracture in horses. Testing through the skin should account for a small constant bias, compared with results for testing directly on exposed bone.
Collapse
|
44
|
Lévesque D, Asaumi Y, Lord M, Bescond C, Hatanaka H, Tagami M, Monchalin JP. Inspection of thick welded joints using laser-ultrasonic SAFT. ULTRASONICS 2016; 69:236-42. [PMID: 27062646 DOI: 10.1016/j.ultras.2016.04.001] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/18/2015] [Revised: 04/01/2016] [Accepted: 04/01/2016] [Indexed: 05/28/2023]
Abstract
The detection of defects in thick butt joints in the early phase of multi-pass arc welding would be very valuable to reduce cost and time in the necessity of reworking. As a non-contact method, the laser-ultrasonic technique (LUT) has the potential for the automated inspection of welds, ultimately online during manufacturing. In this study, testing has been carried out using LUT combined with the synthetic aperture focusing technique (SAFT) on 25 and 50mm thick butt welded joints of steel both completed and partially welded. EDM slits of 2 or 3mm height were inserted at different depths in the multi-pass welding process to simulate a lack of fusion. Line scans transverse to the weld are performed with the generation and detection laser spots superimposed directly on the surface of the weld bead. A CCD line camera is used to simultaneously acquire the surface profile for correction in the SAFT processing. All artificial defects but also real defects are visualized in the investigated thick butt weld specimens, either completed or partially welded after a given number of passes. The results obtained clearly show the potential of using the LUT with SAFT for the automated inspection of arc welds or hybrid laser-arc welds during manufacturing.
Collapse
|
45
|
Lueangapapong P, Oishi H, Suga Y, Yatomi K, Mitome-Mishima Y. Intracranial Aneurysm Model for Detachable Coil Testing. JOURNAL OF THE MEDICAL ASSOCIATION OF THAILAND = CHOTMAIHET THANGPHAET 2016; 99 Suppl 3:S1-S7. [PMID: 29901330] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Intracranial aneurysm is major vascular disease which is life-threatening and challenging treatment. Detachable coil is one of the standard treatments. Because of little knowledge about it, the detachable coils were evaluated by various methods. Animal aneurysm models were also used to test this equipment. In the present study, sidewall aneurysms were created on common carotid arteries of Landrace-Yorkshire-Durocswine. External jugular vein grafts were used as aneurysm sac. End-to-side anastomosis was done. Ten aneurysms were created successfully in 5 swine. There is no perioperative death. This animal aneurysm model is appropriated for coil testing especially in the histopathology aspect.
Collapse
|
46
|
Schulze KA, Wallace V, Hoover T, Salmon E. Using a Dental Student Exercise on Shear Bond Testing to Both Provide Skills Practice and Demonstrate a Research Process. J Dent Educ 2016; 80:473-477. [PMID: 27037456] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2015] [Accepted: 09/25/2015] [Indexed: 06/05/2023]
Abstract
This article describes an exercise with junior dental students at the University of the Pacific Arthur A. Dugoni School of Dentistry designed in part to serve the requirement for dental accreditation Standard 6-3 ("Dental education programs must provide opportunities, encourage, and support student participation in research and other scholarly activities mentored by faculty"). The exercise has been conducted for seven years and has been found to provide a distinctive and important experience to the education of these dental students. The exercise has three aims. First, it is an exercise in which students practice their skills with dental bonding; second, it serves as a tool to give immediate feedback on these skills that is otherwise not possible in a real patient situation; and third, it demonstrates to the students how data from the exercise with the students as subjects can be used in a research study. The project thus serves as an innovative way to use a skill-building exercise to educate students about research at the same time.
Collapse
|
47
|
King JD, York SL, Saunders MM. Design, fabrication and characterization of a pure uniaxial microloading system for biologic testing. Med Eng Phys 2016; 38:411-6. [PMID: 26904918 DOI: 10.1016/j.medengphy.2016.01.011] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2015] [Revised: 01/05/2016] [Accepted: 01/31/2016] [Indexed: 12/18/2022]
Abstract
The field of mechanobiology aims to understand the role the mechanical environment plays in directing cell and tissue development, function and disease. The empirical aspect of the field requires the development of accurate, reproducible and reliable loading platforms that can apply microprecision mechanical load. In this study we designed, fabricated and characterized a pure uniaxial loading platform capable of testing small synthetic and organic specimens along a horizontal axis. The major motivation for platform development was in stimulating bone cells seeded on elastomeric substrates and soft tissue loading. The biological uses required the development of culturing fixtures and environmental chamber. The device utilizes commercial microactuators, load cells and a rail/carriage block system. Following fabrication, acceptable performance was verified by suture tensile testing.
Collapse
|
48
|
Markolf KL, Evseenko D, Petrigliano F. Right-Left Differences in Knee Extension Stiffness for the Normal Rat Knee: In Vitro Measurements Using a New Testing Apparatus. J Biomech Eng 2016; 138:044501. [PMID: 26863930 DOI: 10.1115/1.4032693] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2015] [Indexed: 01/20/2023]
Abstract
Knee stiffness following joint injury or immobilization is a common clinical problem, and the rat has been used as a model for studies related to joint stiffness and limitation of motion. Knee stiffness measurements have been reported for the anesthetized rat, but it is difficult to separate the contributions of muscular and ligamentous restraints to the recorded values. in vitro testing of isolated rat knees devoid of musculature allows measurement of joint structural properties alone. In order to measure the effects of therapeutic or surgical interventions designed to alter joint stiffness, the opposite extremity is often used as a control. However, right-left stiffness differences for the normal rat knee have not been reported in the literature. If stiffness changes observed for a treatment group are within the normal right-left variation, validity of the results could be questioned. The objectives of this study were to utilize a new testing apparatus to measure right-left stiffness differences during knee extension in a population of normal rat knees and to document repeatability of the stiffness measurements on successive testing days. Moment versus rotation curves were recorded for 15 right-left pairs of normal rat knees on three consecutive days, with overnight specimen storage in a refrigerator. Each knee was subjected to ten loading-unloading cycles, with the last loading curve used for analysis. Angular rotation (AR), defined here as the change in flexion-extension angle from a specified applied joint moment, is commonly used as a measure of overall joint stiffness. For these tests, ARs were measured from the recorded test curves with a maximum applied extension moment of 100 g cm. Mean rotations for testing days 2 and 3 were 0.81-1.25 deg lower (p < 0.001) than for day 1, but were not significantly different from each other. For each testing day, mean rotations for right knees were 1.12-1.30 deg greater (p < 0.001) than left knees. These right-left stiffness differences should be considered when interpreting the results of knee treatment studies designed to alter knee stiffness when using the opposite extremity as a control.
Collapse
|
49
|
Sakamoto M. [Estimations of mechanical properties of bones using nanoindentation]. CLINICAL CALCIUM 2016; 26:81-91. [PMID: 26728534] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Nanoindentation has been applied in recent years to measure the mechanical properties of bone tissues at a microscopic scale, overcoming the limitations of traditional mechanical testing techniques for small samples. This method is precise and accurate and appears well suited for measuring mechanical properties in bone. Dynamic nanoindentation is also a promising method of measuring the viscoelastic properties of bone tissues at smaller length and load scales than allowed by other testing methods, thus allowing individual constituents and local regions of inhomogeneous tissues to be characterized individually. This article describes our nanoindentation studies of bone tissues with recent studies.
Collapse
|
50
|
Chabas A, Fouqueau A, Attoui M, Alfaro SC, Petitmangin A, Bouilloux A, Saheb M, Coman A, Lombardo T, Grand N, Zapf P, Berardo R, Duranton M, Durand-Jolibois R, Jerome M, Pangui E, Correia JJ, Guillot I, Nowak S. Characterisation of CIME, an experimental chamber for simulating interactions between materials of the cultural heritage and the environment. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2015; 22:19170-19183. [PMID: 26250811 DOI: 10.1007/s11356-015-5083-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/19/2015] [Accepted: 07/15/2015] [Indexed: 06/04/2023]
Abstract
An approach consisting in combining in situ and laboratory experiments is often favoured for investigating the mechanisms involved in the weathering of the materials of the cultural heritage. However, the realistic simulation in the laboratory of the environmental conditions ruling the interactions of atmospheric compounds with materials is a very complex task. The aim of this work is to characterise CIME, a new chamber specially built to simulate the interactions between materials of the cultural heritage and the environment. The originality of this instrument is that beside the usual climatic parameters (temperature, relative humidity, solar radiation) and gaseous pollutants, it also allows the controlled injection of different types of particulate matter such as terrigenous, marine and anthropogenic. Therefore, varied realistic atmospheric environments (marine or urban) can be easily simulated within CIME. In addition to the technical description of CIME, this paper shows the first results obtained by the impact of gaseous pollutants on non-durable glass, bronze and limestone. The first experiments for the deposition of different particles (calcite, clays, soot and halite) are also presented.
Collapse
|