26
|
Duffy DJ, Curcillo CJ, Chang YJ, Moore GE. Effect of suture caliber on the tensile strength of tenorrhaphies in cadaveric canine tendons. Am J Vet Res 2020; 81:714-719. [PMID: 33112169 DOI: 10.2460/ajvr.81.9.714] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
OBJECTIVE To evaluate the effect of suture caliber on the tensile strength of tenorrhaphies performed with a locking-loop technique in cadaveric canine tendons. SAMPLE 60 superficial digital flexor tendons (SDFTs) from 30 cadaveric adult dogs. PROCEDURES Transverse tenotomy was performed, and SDFTs were repaired with a locking-loop technique and polypropylene suture of 5 randomly assigned calibers: size-0, 2-0, 3-0, 4-0, or 5-0 (n = 12 SDFTs/suture caliber). Tendon constructs were tested to failure. Yield, peak, and failure forces and causes of failure were compared between groups. RESULTS Mean ± SD failure force for the constructs was significantly greater with large-caliber suture (size-0: 73.5 ± 3.1 N; size 2-0: 54.4 ± 7.1 N; size 3-0: 28.7 ± 4.9 N; size 4-0: 18.7 ± 3.4 N; and size 5-0: 8.8 ± 2.8 N). The likelihood of construct failure by suture pullout through the tendon substance increased with large-caliber suture (size-0: 12/12), whereas the likelihood of construct failure by suture breakage increased with small-caliber suture (2-0: 10/12; 3-0, 4-0, and 5-0: 12/12 each). CONCLUSIONS AND CLINICAL RELEVANCE Large-caliber suture had greater tensile strength for tenorrhaphies performed with a locking-loop technique in cadaveric canine tendons. Prior to the use of large-caliber suture in patients requiring tenorrhaphy, however, in vivo studies are required to confirm the results obtained here.
Collapse
|
27
|
Tremolada G, Hazenfield KM, Smeak DD. In vitro holding security of four friction knots of monofilament or multifilament suture used as a first throw for vascular ligation. Am J Vet Res 2020; 81:821-826. [PMID: 32969726 DOI: 10.2460/ajvr.81.10.821] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
OBJECTIVE To evaluate holding security of 4 friction knots created with various monofilament and multifilament sutures in a vascular ligation model. SAMPLE 280 friction knot constructs. PROCEDURES 10 friction knots of 4 types (surgeon's throw, Miller knot, Ashley modification of the Miller knot, and strangle knot) created with 2-0 monofilament (polyglyconate, polydioxanone, poliglecaprone-25, and glycomer-631) and braided multifilament (silk, lactomer, and polyglactin-910) sutures were separately tied on a mock pedicle and pressure tested to the point of leakage. Linear regression analysis was performed to compare leakage pressures among suture materials (within friction knot type) and among knot types (within suture material). RESULTS Mean leakage pressure of surgeon's throws was significantly lower than that of all other knots tested, regardless of the suture material used. All the other knots had mean leakage pressures considered supraphysiological. Significant differences in mean leakage pressure were detected between various friction knots tied with the same type of suture and various suture types used to create a given knot. Variability in leakage pressure among knots other than the surgeon's throw was greatest for poliglecaprone-25 and lowest for polydioxanone. CONCLUSIONS AND CLINICAL RELEVANCE Most differences in knot security, although statistically significant, may not have been clinically relevant. However, results of these in vitro tests suggested the surgeon's throw should be avoided as a first throw for pedicle ligation and that poliglecaprone-25 may be more prone to friction knot slippage than the other suture materials evaluated.
Collapse
|
28
|
McCagherty J, Yool DA, Paterson GK, Mitchell SR, Woods S, Marques AI, Hall JL, Mosley JR, Nuttall TJ. Investigation of the in vitro antimicrobial activity of triclosan-coated suture material on bacteria commonly isolated from wounds in dogs. Am J Vet Res 2020; 81:84-90. [PMID: 31887087 DOI: 10.2460/ajvr.81.1.84] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
OBJECTIVE To investigate in vitro effects of triclosan coating of suture materials on the growth of clinically relevant bacteria isolated from wounds in dogs. SAMPLE 6 types of suture material and 10 isolates each of methicillin-susceptible Staphylococcus pseudintermedius, methicillin-resistant S pseudintermedius, Escherichia coli, and AmpC β-lactamase and extended-spectrum β-lactamase-producing E coli from clinical wound infections. PROCEDURES Isolates were cultured on Mueller-Hinton agar with 3 types of triclosan-coated suture, uncoated counterparts of the same suture types, and positive and negative controls. Zones of inhibition (ZOIs) were measured after overnight incubation. Sustained antimicrobial activity assays were performed with susceptible isolates. The ZOI measurements and durations of sustained antimicrobial activity were compared among suture types and isolates by statistical methods. Suture surface characteristics and bacterial adherence were evaluated qualitatively with scanning electron microscopy. RESULTS ZOIs were generated only by triclosan-coated materials; triclosan-coated suture had sustained antimicrobial activity (inhibition) for 3 to 29 days against all tested pathogens. The ZOIs around triclosan-coated suture were significantly greater for S pseudintermedius isolates than for E coli isolates. Bacterial adherence to uncoated polyglactin-910 was greatest, followed by triclosan-coated polyglactin-910, and then uncoated monofilament sutures, with least adherence to coated monofilament sutures. CONCLUSIONS AND CLINICAL RELEVANCE Surface characteristics of suture materials may be as important or more important than triclosan coating for microbial inhibition; however, triclosan coating appeared to affect bacterial adherence for multifilament sutures. Triclosan-coated, particularly monofilament, sutures inhibited pathogens commonly isolated from wounds of dogs, including multidrug-resistant bacteria. Further studies are required to assess clinical efficacy of triclosan-coated suture materials in vivo.
Collapse
|
29
|
Scott JE, Singh A, Case JB, Mayhew PD, Runge JJ. Determination of optimal location for thoracoscopic-assisted pulmonary surgery for lung lobectomy in cats. Am J Vet Res 2020; 80:1050-1054. [PMID: 31644337 DOI: 10.2460/ajvr.80.11.1050] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
OBJECTIVE To determine the optimal intercostal space (ICS) for thoracoscopic-assisted pulmonary surgery for lung lobectomy in cats. SAMPLE 8 cat cadavers. PROCEDURES Cadavers were placed in lateral recumbency. A 5-cm minithoracotomy incision was made in the middle third of ICS 4 through 7 on the left side and 4 through 8 on the right side, and a wound retractor device was placed. A camera port was made in the middle third of ICS 9. Each lung lobe was sequentially exteriorized at each respective ICS. A thoracoabdominal stapler was placed to simulate a lung lobectomy, and distance from the stapler anvil to the hilus was measured. RESULTS For the left cranial lung lobe, there was no significant difference in median distance from the stapler anvil to the pulmonary hilus for ICS 4 through 6. Simulated lobectomy of the left caudal lung lobe performed at ICS 5 and 6 resulted in a significantly shorter distance, compared with lobectomy performed at ICS 4 and 7. Simulated lobectomy of the right cranial and right middle lung lobes performed at ICS 4 and 5 resulted in a significantly shorter distance, compared with lobectomy performed at ICS 7. Simulated lobectomy of the accessory and right caudal lung lobes at ICS 5 and 6 resulted in a significantly shorter distance than for lobectomy performed at ICS 8. CONCLUSIONS AND CLINICAL RELEVANCE An optimal ICS for a minithoracotomy incision was determined for thoracoscopic-assisted lung lobectomy in cats.
Collapse
|
30
|
Lozier JW, Niehaus AJ, Hinds CA, Durgam SS, Jones SC, Lakritz J. Investigation of a novel prosthesis technique for extracapsular stabilization of cranial cruciate ligament-deficient stifle joints in adult cattle. Am J Vet Res 2019; 80:779-786. [PMID: 31339759 DOI: 10.2460/ajvr.80.8.779] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
OBJECTIVE To evaluate a novel prosthesis technique for extracapsular stabilization of cranial cruciate ligament (CCL)-deficient stifle joints in adult cattle. SAMPLE 13 cadaveric bovine stifle joint specimens. PROCEDURES In the first of 3 study phases, the most isometric points on the distal aspect of the femur (distal femur) and proximal aspect of the tibia (proximal tibia) were determined from measurements obtained from lateromedial radiographs of a stifle joint specimen maintained at angles of 135°, 90°, 65°, and 35°. During phase 2, 800-lb-test monofilament nylon leader line was cut into 73-cm-long segments. Each segment was secured in a loop by use of 2, 3, or 4 crimping sleeves such that there were 12 replicates for each construct. Each loop was distracted to failure at a constant rate of 1 mm/s. Mean force at failure and elongation and mode of failure were compared among the 3 constructs. During phase 3, bone tunnels were created in the distal femur and proximal tibia at the isometric points identified during phase 1 in each of 12 CCL-deficient stifle joint specimens. The 3-sleeve construct was applied to each specimen. Specimens were distracted to failure at a constant rate of 1 mm/s. RESULTS Among the 3 constructs evaluated, the 3-sleeve construct was considered optimal in terms of strength and amount of foreign material. In phase 3, all replicates failed because of suture slippage. CONCLUSIONS AND CLINICAL RELEVANCE Use of 800-lb-test monofilament nylon leader line as a prosthesis might be a viable alternative for extracapsular stabilization of CCL-deficient stifle joints in adult cattle. Further in vivo studies are necessary.
Collapse
|
31
|
McGlinchey L, Boone LH, Munsterman AS, Coleridge MOD, Rosanowski SM, Farag R, Hanson RR. In vitro evaluation of the knot-holding capacity and security, weight, and volume of forwarder knots tied with size-3 polyglactin 910 suture exposed to air, balanced electrolyte solution, or equine abdominal fat. Am J Vet Res 2019; 80:709-716. [PMID: 31246130 DOI: 10.2460/ajvr.80.7.709] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
OBJECTIVE To evaluate the effect of exposure to a balanced electrolyte solution (BES), or equine abdominal fat on the knot-holding capacity (KHC), relative knot security (RKS), weight, and volume of forwarder knots versus surgeon's knots. SAMPLE 315 knots tied and tested in vitro. PROCEDURES United States Pharmacopeia size-3 polyglactin 910 suture exposed to air (dry [control]), equine abdominal fat (fat-exposed), or BES (BES-exposed) was used to tie forwarder knots with 2, 3, and 4 throws and surgeon's knots with 5, 6, 7, and 8 throws. A universal materials testing machine was used to test the tensile strength of suture and knots to failure, and the KHC, RKS, weight, and volume of knots were determined. RESULTS Forwarder knots had significantly higher KHC and RKS and lower volume, compared with surgeons' knots. Forwarder knots tied with fat-exposed suture had greater weight, but not volume, than did forwarder knots tied with dry or BES-exposed suture with the same number of throws. CONCLUSIONS AND CLINICAL RELEVANCE Results indicated that forwarder knots were superior to surgeon's knots when configured as start knots intended for continuous lines of suture. Exposure to media did not negatively affect mechanical or physical properties of forwarder knots and may improve specific biomechanical functions, including KHC and RKS.
Collapse
|
32
|
Martin Y, Johnson MD, Travers CJ, Colee J, McConkey MJ, Banks SA. Biomechanical comparison of four prosthetic ligament repair techniques for tarsal medial collateral ligament injury in dogs. Am J Vet Res 2019; 80:469-479. [PMID: 31034275 DOI: 10.2460/ajvr.80.5.469] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
OBJECTIVE To compare joint stability and ultimate strength among 4 prosthetic ligament constructs for repair of tarsal medial collateral ligament (MCL) injury in dogs. SAMPLE 13 canine cadavers (26 hind limbs). PROCEDURES Each limb was stripped of all soft tissues except those associated with the tarsal joint and assigned to 1 of 4 prosthetic ligament constructs. The AN construct consisted of 3 bone anchors connected with monofilament nylon suture. The AU construct consisted of low-profile suture anchors connected with multifilament ultrahigh-molecular-weight polyethylene (UHMWPE) suture. The TN and TU constructs involved the creation of 3 bone tunnels and use of nylon or UHMWPE suture, respectively. Each limb underwent biomechanical testing before and after MCL transection and before and after cyclic range-of-motion testing following completion of the assigned construct. Tarsal joint stability (extent of laxity) was assessed with the joint in each of 3 positions (75°, 135°, and 165°). After completion of biomechanical testing, each limb was tested to failure to determine the ultimate strength of the construct. RESULTS Relative to intact tarsal joints, joint laxity was significantly increased following completion of all 4 constructs. Construct type was not associated with the magnitude of change in joint laxity. Ultimate strength was greatest for the UHMWPE-suture constructs. CONCLUSIONS AND CLINICAL RELEVANCE Results indicated that all 4 constructs effectively stabilized MCL-deficient tarsal joints. Implants used for the TU, TN, and AU constructs had a lower profile than those used for the AN construct, which may be clinically advantageous. In vivo studies are warranted.
Collapse
|
33
|
Soula M, Shmalberg JW, Johnson MD. Biomechanical comparison of a modified three-loop pulley technique and a three-level self-locking technique for repair of patellar tendon rupture in dogs. Am J Vet Res 2019; 80:335-341. [PMID: 30919675 DOI: 10.2460/ajvr.80.4.335] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
OBJECTIVE To compare use of a 3-level self-locking suture (3LSLS) technique with use of a previously described modified 3-loop pulley (M3LP) technique to repair rupture of the proximal aspect of patellar tendons in limbs from canine cadavers. SAMPLE Paired hind limbs of 6 adult mixed-breed dogs. PROCEDURES A limb from each pair was randomly assigned to be repaired by the 3LSLS technique or M3LP technique with size-2 ultrahigh-molecular-weight polyethylene and size-0 monofilament polypropylene suture, respectively. Limbs were prepared, and each patellar tendon was transected at a site chosen to simulate rupture at the proximal aspect. Tendons were repaired with the assigned techniques and mechanically tested with a biaxial servohydraulic test system; the clamp was distracted until the repair failed. Force at 1 -mm gap formation, 3-mm gap formation, and repair failure and gap size at failure were measured and compared between methods. Mode of failure was recorded. RESULTS There was no significant difference between methods for the force required to produce a 1 - or 3-mm gap in the repair. The 3LSLS technique required a significantly higher load for complete failure; gap formation immediately before failure was significantly greater for this method than for the M3LP technique. Four of 6 repairs with the M3LP technique and 0 of 6 repairs with the 3LSLS technique failed by suture breakage. CONCLUSIONS AND CLINICAL RELEVANCE The 3LSLS technique with size-2 ultrahigh-molecular-weight polyethylene suture was as effective at resistance to 1 - and 3-mm gap formation as the M3LP with size-0 monofilament polypropylene suture.
Collapse
|
34
|
Nutt LK, Wilson ML, Sakals S. Comparison of surgical time and complication rate of subcutaneous and skin closure using barbed suture or traditional knotted suture in dogs. THE CANADIAN VETERINARY JOURNAL = LA REVUE VETERINAIRE CANADIENNE 2017; 58:1281-1286. [PMID: 29203937 PMCID: PMC5680738] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
This prospective study evaluated the handling, intraoperative and postoperative complication rates of a barbed knotless suture for closure of subcutaneous tissue and skin in 17 client-owned dogs (group A) following a tibial plateau leveling osteotomy procedure. Clinical characteristics, surgical time, and complication rates were compared to a control group of 17 client-owned dogs (group B) with subcutaneous tissue and skin closure using traditional suture material. Signalment was not significantly different between groups and did not have an effect on complication rates. Surgical times were not significantly different for subcutaneous tissue or skin closure between the 2 groups. There were significantly more intraoperative complications in the barbed suture group (A: 4/17; B: 0/17; P = 0.033) but no difference in minor or major postoperative complication rates (minor A: 2/16; B: 1/14; P = 0.626, major A: 2/16; B: 0/14; P = 0.171).
Collapse
|
35
|
Faria MCF, de Almeida FM, Serrão ML, de Oliveira Almeida NK, Labarthe N. Use of cyanoacrylate in skin closure for ovariohysterectomy in a population control programme. J Feline Med Surg 2017; 7:71-5. [PMID: 15771943 DOI: 10.1016/j.jfms.2004.05.003] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/25/2004] [Indexed: 11/18/2022]
Abstract
N-butyl-cyanoacrylate tissue adhesive was evaluated as a skin closure material in a population control programme. Fifty-two female cats underwent ovariohysterectomy: skin closure of 25 of those cats was undertaken with nylon (3–0) and in 27 with the adhesive. Twenty-three cats spent the postoperative period confined in cages and 29 were free within a 50-square-metre fenced area. The parameters used for evaluation were: dehiscence or secretion and presence and extension of erythema at the surgical site. It was observed that the time required for closure of the surgical site with the adhesive was shorter than with nylon, saving approximately 1 min per animal. The adhesive or conventional suture allowed similar healing, and independent of material used for skin closure or the postoperative exercise, there was no statistical difference in wound cicatrization. As the adhesive eliminates the need for suture removal and decreases surgery time, without additional risk to the cat, it may be indicated for surgical population control programmes.
Collapse
|
36
|
Avoine X, Lussier B, Brailovski V, Inaekyan K, Beauchamp G. Evaluation of the effect of 4 types of knots on the mechanical properties of 4 types of suture material used in small animal practice. CANADIAN JOURNAL OF VETERINARY RESEARCH = REVUE CANADIENNE DE RECHERCHE VETERINAIRE 2016; 80:162-170. [PMID: 27127344 PMCID: PMC4836043] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Received: 05/11/2015] [Accepted: 11/23/2015] [Indexed: 06/05/2023]
Abstract
The influence of the type of material used, knot configuration, and use of an additional throw on the tensile force at failure, the elongation, and the mode of failure of different configurations of linear sutures and knotted suture loops was evaluated in this in-vitro mechanical study. We hypothesized that all types of knots would significantly influence the initial force and elongation of suture materials and would influence the force and elongation at which the knotted loops break, but not their mode of failure. A total of 432 samples of 4 types of size 3-0 suture material (polydioxanone, polyglecaprone 25, polyglactin 910, and nylon), representing 9 configurations, were tested in a tensiometer. The configurations were 1 linear suture without a knot and the following loops: square (SQ) knot; surgeon's (SU) knot; granny (GR) knot; and sliding half-hitch (SHH) knot using either 4 and 5 or 3 and 4 throws, depending on the material. For polydioxanone, SQ and SU knots did not decrease the initial force at failure of the suture. Granny (GR) and SHH knots decreased the tensile force at failure and elongation by premature failure of the loop. For polyglecaprone 25, all knots decreased the initial force at failure of the suture, with SHH being weaker than the other knots. For coated polyglactin 910, all knots decreased the initial force at failure of the suture and slippage increased significantly compared with the other 3 sutures. The use of SQ knots with 3 throws did not result in a safe knot. For nylon, knots did not alter the original mechanics of the suture. In conclusion, all knots and types of suture material do not necessarily have the same effect on the initial tensile force at failure of suture materials.
Collapse
|
37
|
Abstract
The diversity implicit in exotic animal surgery requires a tailored approach to optimize successful outcomes. Outlined is information on patient preparation, instrumentation, hemostatic techniques, and magnification as it pertains to the exotic animal. Application of topical antiseptic solutions and judicious removal of pelage and feathers will decrease bacterial load during patient preparation. The use of specific barrier protection ensures proper aseptic technique and enables optimal patient monitoring. Magnification combined with a focal light source enhances visual acuity, allowing for better use of delicate instrumentation and identification of anatomic structures.
Collapse
|
38
|
Abstract
Basic surgical instrumentation for avian soft tissue surgery includes soft tissue retractors, microsurgical instrumentation, surgical loupes, and head-mounted lights. Hemostasis is fundamental during the surgical procedures. The indications, approach, and complications associated with soft tissue surgeries of the integumentary (digit constriction repair, feather cyst excision, cranial wound repair, sternal wound repair, uropygial gland excision), gastrointestinal (ingluviotomy, crop biopsy, crop burn repair, celiotomy, coelomic hernia and pseudohernia repair, proventriculotomy, ventriculotomy, enterotomy, intestinal resection and anastomosis, cloacoplasty, cloacopexy), respiratory (rhinolith removal, sinusotomy, tracheotomy, tracheal resection and anastomosis, tracheostomy, pneumonectomy) and reproductive (ovocentesis, ovariectomy, salpingohysterectomy, cesarean section, orchidectomy, vasectomy, phallectomy) systems are reviewed.
Collapse
|
39
|
Rousseau M, Anderson DE, Rozell TG, Hand JM, Faris BR. Comparison of polyglactin-910 and polydioxanone for closure of the linea alba following caudal ventral midline laparotomy in sheep. THE CANADIAN VETERINARY JOURNAL = LA REVUE VETERINAIRE CANADIENNE 2015; 56:959-963. [PMID: 26345301 PMCID: PMC4535513] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
This study compared incisional complications after ventral midline laparotomy using 2 absorbable suture materials for apposition of the linea alba in sheep. The linea alba of 93 yearling sheep was sutured by 3 veterinarians in a simple continuous pattern using either polyglactin 910 (PG910; group PG) or polydioxanone (PDS; group PD). A blinded observer assessed surgical sites at the time of suture removal. Multivariate logistic regression was used to assess the association between incisional complications and variables (suture material used, veterinarian, skin suture removal time). The odds of incisional complications did not vary significantly with the type of suture material used (P = 0.11), veterinarian (P = 0.61) or skin suture removal time (P = 0.36). Most incisional complications were cutaneous suture sinus formation. Either PG910 or PDS may be used for linea alba closure in sheep.
Collapse
|
40
|
Benlloch-Gonzalez M, Gomes E, Bouvy B, Poncet C. Long-term prospective evaluation of intestinal anastomosis using stainless steel staples in 14 dogs. THE CANADIAN VETERINARY JOURNAL = LA REVUE VETERINAIRE CANADIENNE 2015; 56:715-722. [PMID: 26130833 PMCID: PMC4466822] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
This prospective clinical study evaluated the use, complications, and clinical and ultrasonographic follow-ups of end-to-end intestinal anastomoses with skin staples in naturally occurring diseases in canine small and large intestines. Intestinal anastomoses were performed in 14 dogs and pre-, peri-, and postoperative data were recorded. Postoperative clinical and ultrasound evaluations were performed at regular intervals for 1 year. The mean time taken to construct the anastomosis was 5 min. There were no intraoperative complications. Hemorrhage and colonic stricture were the main postoperative complications. Staple loss occurred in 2 cases. Absence of wall layering and focal wall thickening were observed in all cases at each ultrasonographic follow-up. Hyperechoic fat was observed in all but 1 of the cases at month 1. Nine dogs were alive with normal digestive function at the end of the study. The skin stapler technique enabled rapid construction of consistent anastomoses with inexpensive stapling material.
Collapse
|
41
|
Atwood C, Maxwell M, Butler R, Wills R. Effects of incision closure method on infection prevalence following tibial plateau leveling osteotomy in dogs. THE CANADIAN VETERINARY JOURNAL = LA REVUE VETERINAIRE CANADIENNE 2015; 56:375-381. [PMID: 25829557 PMCID: PMC4357910] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
The goal of this study was to retrospectively investigate the effect of incisional closure with either stainless steel skin staples or intradermal poliglecaprone 25 on the prevalence of surgical site infection following tibial plateau leveling osteotomy in dogs. Medical records were reviewed for dogs treated with unilateral tibial plateau leveling osteotomy at Memphis Veterinary Specialists between 2006 and 2013. Procedures (n = 306) from 242 dogs were included in the study. The association of potential risk factors with the occurrence of postoperative infection was assessed using logistic regression. A value of P < 0.05 was considered significant. Weight and administration of postoperative antimicrobials were found to significantly influence surgical site infection prevalence. No significant association was noted between closure method and prevalence of postoperative infection.
Collapse
|
42
|
Anderson SL, Bracamonte JL, Hendrick S. Ex vivo evaluation of 7 polydioxanone for closure of equine ventral midline celiotomies. CANADIAN JOURNAL OF VETERINARY RESEARCH = REVUE CANADIENNE DE RECHERCHE VETERINAIRE 2014; 78:156-160. [PMID: 24688180 PMCID: PMC3962281] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Received: 02/19/2013] [Accepted: 04/23/2013] [Indexed: 06/03/2023]
Abstract
The objective of this study was to compare the bursting strength (BS) and mode of failure (MF) of ventral midline (VM) celiotomies closed with USP 7 polydioxanone (7PD) in 1 or 2 simple continuous sections. A bursting strength model, consisting of inserting and inflating a 200-L polyurethane bladder through a 25-cm VM celiotomy, was used on 15 fresh equine cadavers. Celiotomies were closed using 7PD in 2 separate sections (4 knots), 2 continuous sections (3 knots), or a single section (2 knots) using a simple continuous pattern. The horses' signalment, body weight, number of total knots, MF, and BS were recorded and analyzed statistically for interactions. No difference was found between the BS of VM celiotomies closure types (P = 0.4). All celiotomy/ suture constructs failed at the abdominal wall. The celiotomy closure types evaluated in this study provided a secure method of closure in VM celiotomies in vivo.
Collapse
|
43
|
Puttick JL, Sereda CW. Suture-related urolithiasis following repair of inadvertent prostatectomy in a dog. THE CANADIAN VETERINARY JOURNAL = LA REVUE VETERINAIRE CANADIENNE 2012; 53:787-790. [PMID: 23277648 PMCID: PMC3377465] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
A 10-month-old male chow chow mixed breed dog was presented for anuria secondary to inadvertent prostatectomy performed during unilateral cryptorchidectomy. Surgical repair was successfully performed; however, this resulted in suture-associated urolith formation 3 months later, requiring a second surgical intervention and urethrostomy.
Collapse
|
44
|
Hebert S. Use of suture materials in practice. Vet Rec 2012; 170:236. [PMID: 22391910 DOI: 10.1136/vr.e1513] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
|
45
|
Mesa MG, Magie RJ, Copeland ES, Christiansen HE. Surgical wound healing in radio-tagged adult Pacific lamprey Entosphenus tridentatus held on different substrata. JOURNAL OF FISH BIOLOGY 2011; 79:1068-1075. [PMID: 21967590 DOI: 10.1111/j.1095-8649.2011.03071.x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
Radio-tagged adult Pacific lamprey Entosphenus tridentatus held in a raceway with Plexiglas-lined walls and bottom healed more slowly and retained sutures longer than fish held in an all-concrete raceway or one with Plexiglas walls and a cobble-lined bottom. On all substrata, healing depended on when sutures were lost, and fish that lost their sutures in <14 days post-surgery healed faster than those that kept sutures longer. Long-term suture retention led to tissue trauma, infection and poor survival.
Collapse
|
46
|
Witte TH, Cheetham J, Rawlinson JJ, Soderholm LV, Ducharme NG. A transducer for measuring force on surgical sutures. CANADIAN JOURNAL OF VETERINARY RESEARCH = REVUE CANADIENNE DE RECHERCHE VETERINAIRE 2010; 74:299-304. [PMID: 21197230 PMCID: PMC2949343] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Received: 08/05/2009] [Accepted: 12/02/2009] [Indexed: 05/30/2023]
Abstract
The objective of this study was to validate, both in vitro and in an ex vivo model, a technique for the measurement of forces exerted on surgical sutures. For this purpose, a stainless steel E-type buckle force transducer was designed and constructed. A strain gauge was mounted on the central beam of the transducer to measure transducer deformation. The transducer was tested and calibrated on a single strand of surgical suture during cyclic loading. Further validation was performed using a previously published cadaveric model of laryngoplasty in the horse. Linear regression of transducer output with actual force during calibration tests resulted in mean R² values of 1.00, 0.99, and 0.99 for rising slope, falling slope, and overall slope, respectively. The R² was not less than 0.96 across an average of 75 cycles per test. The difference between rising slope and falling slope was 4%. Over 45 846 samples, the predicted force from transducer output showed a mean error of 4%. In vitro validation produced an adjusted R² of 0.99 when the force on the suture was regressed against translaryngeal pressure in a mixed-effects model. E-type buckle force transducers showed a highly linear output over a physiological force range when applied to surgical suture in vitro and in an ex vivo model of laryngoplasty. With appropriate calibration and short-term in vivo implantation, these transducers may advance our knowledge of the mechanisms of success and failure of techniques, such as laryngoplasty, that use structural suture implants.
Collapse
|
47
|
Papazoglou LG, Tsioli V, Papaioannou N, Georgiadis M, Savvas I, Prassinos N, Kouti V, Bikiaris D, Hadzigiannakis C, Zavros N. Comparison of absorbable and nonabsorbable sutures for intradermal skin closure in cats. THE CANADIAN VETERINARY JOURNAL = LA REVUE VETERINAIRE CANADIENNE 2010; 51:770-772. [PMID: 20885834 PMCID: PMC2885123] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
Paired skin incisions were made in 6 cats and closed intradermally with the copolymer of glycolide, ɛ-caprolacton, and trimethylene-carbonate, or polypropylene suture. The macroscopic and histologic appearance of the incisions was compared. Polypropylene suture compared favorably to glycolide, ɛ-caprolacton, and trimethylene-carbonate suture for closure of skin incisions in cats.
Collapse
|
48
|
Proudman CJ, Edwards GB, Barnes J. Differential survival in horses requiring end-to-end jejunojejunal anastomosis compared to those requiring side-to-side jejunocaecal anastomosis. Equine Vet J 2010; 39:181-5. [PMID: 17378448 DOI: 10.2746/042516407x171354] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
REASONS FOR PERFORMING STUDY Horses requiring different methods of intestinal anastomosis during equine colic surgery may have differences in mortality and morbidity. HYPOTHESES Horses requiring side-to-side jejunocaecal anastomosis have a higher mortality and morbidity rate than those requiring end-to-end jejunojejunal anastomosis. Morbidity and mortality of handsewn vs. stapled side-to-side jejunocaecal anastomoses are not significantly different. METHODS A prospective, nonrandomised, observational study was conducted. Clinical and surgical details were recorded during hospitalisation and survival data acquired by periodic telephone questionnaire. Differences in mortality and morbidity rate were evaluated by survival analysis. RESULTS A total of 184 horses underwent end-to-end jejunojejunal anastomosis and 178 underwent side-to-side jejunocaecal anastomosis. Horses with a jejunocaecal anastomosis had a significantly higher mortality rate. The incidence of post operative colic in horses requiring side-to-side jejunocaecal anastomoses was greater than those requiring end-to-end jejunojejunal anastomoses. Within the group undergoing side-to-side jejunocaecal anastomosis there was no evidence of differential survival between horses with handsewn vs. stapled anastomoses. CONCLUSIONS Mortality rate is higher in horses that have required side-to-side jejunocaecal anastomosis than in those that needed end-to-end jejunojejunal anastomosis; and post operative colic is more common after side-to-side jejunocaecal anastomosis. No difference in mortality was found between horses with handsewn and stapled side-to-side jejunocaecal anastomoses. POTENTIAL RELEVANCE Surgeons should be aware of the increased mortality and morbidity in horses requiring side-to-side jejunocaecal anastomosis. Our finding of no difference in mortality between handsewn and stapled side-to-side jejunocaecal anastomoses justifies surgeons exercising personal preference in their selection of anastomosis method.
Collapse
|
49
|
Anderson ET, Davis AS, Law JM, Lewbart GA, Christian LS, Harms CA. Gross and histologic evaluation of 5 suture materials in the skin and subcutaneous tissue of the California sea hare (Aplysia californica). JOURNAL OF THE AMERICAN ASSOCIATION FOR LABORATORY ANIMAL SCIENCE : JAALAS 2010; 49:64-68. [PMID: 20122319 PMCID: PMC2824970] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Received: 05/12/2009] [Revised: 07/07/2009] [Accepted: 08/12/2009] [Indexed: 05/28/2023]
Abstract
Invertebrates are increasing in their importance to both the public and private aquarium trade and play a vital role in biomedical research. Surgical techniques have become an important approach to obtaining data and maintaining good health in both of these areas. However, studies examining tissue reaction to suture material in invertebrates are lacking. The current study evaluated the gross and histologic reaction of Aplysia californica to 5 commonly used suture materials, including polydioxanone, black braided silk, polyglactin 910, monofilament nylon, and monofilament poliglecaprone. Histologic samples were graded on the amount of edema (score, 1 to 4), inflammation (1 to 4), and granuloma formation (1 to 4) present, and a final overall histology score (1 to 6) was assigned to each sample. Compared with untreated control tissue, all suture materials caused significantly increased tissue reaction, but the overall histology score did not differ among the suture materials. Silk was the only suture that did not have a significantly increased granuloma score when compared with the control. Although none of the suture materials evaluated seemed clearly superior for use in Aplysia, we recommend silk because of its less robust granuloma induction, which is favorable in a clinical and research setting.
Collapse
|
50
|
Kelmer G, Schumacher J. Repair of abdominal wall hernias in horses using primary closure and subcutaneous implantation of mesh. Vet Rec 2008; 163:677-679. [PMID: 19060315] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
Abdominal incisional hernias in over 40 horses were repaired by exposing the hernial sac and ring and closing the ring with absorbable, interrupted, inverted, cruciate sutures after inverting the hernial sac into the peritoneal cavity. A mesh was sutured, under tension, over the closed ring. Placing the mesh subcutaneously, rather than in the retroperitoneal space, simplified the dissection and minimised the likelihood of penetrating the peritoneal cavity, a problem common to techniques of hernia repair in which the mesh is implanted into the retroperitoneal space. Implanting the mesh subcutaneously created a strong repair, the typical result of which was a cosmetically acceptable, uniformly flat appearance to the ventral aspect of the abdomen. There were few complications and there was only one failure, due to the tissue surrounding the mesh becoming infected.
Collapse
|