576
|
Mor-Avi V, Shroff SG, Robinson KA, Cholley BP, Ng AF, Lang RM. Echocardiographic contrast agents and left ventricular contractility: evaluation using an isolated rabbit heart model. J Am Soc Echocardiogr 1996; 9:452-61. [PMID: 8827628 DOI: 10.1016/s0894-7317(96)90116-9] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
The effects of Albunex (Molecular Biosystems, Inc., San Diego, Calif.) and a second generation contrast agent, FS069, on left ventricular (LV) contractility were evaluated using an isolated rabbit heart model under constant loading conditions and heart rate. Contrast injections (2 ml total volume) were performed in two separate protocols (N1 = 6, N2 = 6). In protocol 1, various doses of Albunex (0.1 to 2.0 ml in saline solution) were used, and paired control injections of a matched dose of 5% solution of human albumin in saline solution were administered. In protocol 2, LV contractility was assessed during injections of the following solutions: (1) 1:250 suspension of FS069 in saline solution, which caused optimal myocardial contrast enhancement; (2) a 1:25 suspension of FS069; (3) a 1:25 suspension of FS069 prefiltered using an 8 microns pore filter; and (4) 2 ml saline solution as a control. Instantaneous LV pressure was analyzed for variations in peak systolic pressure (peak P) and maximum pressure derivative (peak P'), both indices of LV contractility under conditions of fixed heart rate and chamber volume. Albumin alone caused a transient, dose-dependent depression of LV contractility, reflected by decreases in both peak P and peak P' values. These decreases presumably were caused by the decreasing availability of ionized calcium as a result of calcium binding. No further decrease in contractility was noted when Albunex microspheres were present in the solution. Saline injections caused a transient minor increase in LV contractility, reflected by increases of 4.5% +/- 1.1% and 10.6% +/- 3.8% in peak P and peak P' values, respectively. These levels returned to baseline levels within 2 minutes. A similar response was observed when a 1:250 suspension of FS069 was used. The 1:25 suspension of FS069 caused a bimodal response, with initial rises in peak P and peak P' levels (5.2% +/- 3.6% and 12.8% +/- 6.5%, respectively), followed by minor reductions in contractility (2.0% +/- 2.4% and 1.7% +/- 2.1%, respectively). The latter decrease in contractility caused by the 1:25 suspension of FS069 was eliminated by filtering. The isolated rabbit heart model is a highly sensitive tool that allows accurate and direct assessment of possible adverse effects of intravascular contrast agents on LV contractility. Using this model, we showed that neither Albunex microspheres nor FS069 microspheres impaired myocardial contractility.
Collapse
|
577
|
Cholley BP, Shroff SG, Korcarz C, Lang RM. Aortic elastic properties with transesophageal echocardiography with automated border detection: validation according to regional differences between proximal and distal descending thoracic aorta. J Am Soc Echocardiogr 1996; 9:539-48. [PMID: 8827637 DOI: 10.1016/s0894-7317(96)90125-x] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
We have previously described the use of transesophageal echocardiography with automated border detection to quantify regional aortic elastic properties. The purpose of this study was to validate this technique further by measuring regional variations of aortic elastic properties and comparing them with previously published data acquired by invasive methods. In nine anesthetized, closed-chest dogs, aortic pressure and lumenal area (transesophageal echocardiography with automated border detection) signals were recorded simultaneously at two aortic sites: just distal to the branching site of the left subclavian artery (proximal) and at the level of the diaphragm (distal). Instantaneous wall thickness was estimated by combining M-mode measurement of aortic end-diastolic thickness with instantaneous lumenal area. Data were acquired over a wide range of loading conditions, generated by inferior vena caval balloon occlusion. Aortic compliance per unit length, midwall radius, midwall stress, and incremental elastic modulus were computed. Aortic midwall radius and incremental elastic modulus values for proximal and distal aortic sites were compared at a common level of midwall stress. Compliance per unit length was higher in the proximal compared with the distal descending thoracic aorta (0.013 +/- 0.003 versus 0.008 +/- 0.003 cm2/mm Hg; mean +/- SD; p = 0.0011). Midwall radius was larger at the proximal location (0.76 +/- 0.07 cm versus 0.64 +/- 0.07 cm; p = 0.0001), whereas incremental elastic modulus was greater distally (0.799 +/- 0.052 dynes x 10(6)/cm2 versus 0.912 +/- 0.130 dynes x 10(6)/cm2; p = 0.02). Lower compliance values at the distal site of the descending thoracic aorta resulted from greater wall stiffness and a smaller radius. Transesophageal echocardiography with automated border detection provides reliable measurements of instantaneous aortic areas necessary for quantifying regional elastic properties.
Collapse
|
578
|
Lang RM, Vignon P, Weinert L, Bednarz J, Korcarz C, Sandelski J, Koch R, Prater D, Mor-Avi V. Echocardiographic quantification of regional left ventricular wall motion with color kinesis. Circulation 1996; 93:1877-85. [PMID: 8635267 DOI: 10.1161/01.cir.93.10.1877] [Citation(s) in RCA: 143] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Color kinesis is a new technology for the echocardiographic assessment of left ventricular wall motion based on acoustic quantification. This technique automatically detects endocardial motion in real time by using integrated backscatter data to identify pixel transitions from blood to tissue during systole on a frame-by-frame basis. In this study, we evaluated the feasibility and accuracy of quantitative segmental analysis of color kinesis images to provide objective evaluation of regional systolic endocardial motion. METHODS AND RESULTS Two-dimensional echocardiograms were obtained in the short-axis and apical four-chamber views in 20 normal subjects and 40 patients with regional wall motion abnormalities. End-systolic color overlays superimposed on the gray scale images were obtained with color kinesis to color encode left ventricular endocardial motion throughout systole on a frame-by-frame basis. These color-encoded images were divided into segments by use of custom software. In each segment, pixels of different colors were counted and displayed as stacked histograms reflecting the magnitude and timing of regional endocardial excursion. In normal subjects, histograms were found to be highly consistent and reproducible. The patterns of contraction obtained in normal subjects were used as a reference for the objective automated interpretation of regional wall motion abnormalities, defined as deviations from this pattern. The variability in the echocardiographic interpretation of wall motion between two experienced readers was similar to the diagnostic variability between the consensus of the two readers and the automated interpretation. CONCLUSIONS Color kinesis is a promising new tool that may be used clinically to improve the qualitative and quantitative evaluation of spatial and temporal aspects of global and regional wall motion. In this initial study, segmental analysis of color kinesis images provided accurate, automated, and quantitative diagnosis of regional wall motion abnormalities.
Collapse
|
579
|
Abstract
An accurate echocardiographic assessment of aortic stenosis is critical for the cost-effective diagnosis and management of patients with the clinical suspicion of this diagnosis. Although the concepts involved in the echocardiographic determination of aortic pressure gradients and valve areas are relatively simple, acquisition of the data required to perform these calculations can at times be technically challenging. After reviewing the clinical signs and symptoms and the hemodynamics of aortic stenosis, this article reviews in detail the technical aspects involved in obtaining accurate gradients and valve areas emphasizing potential pitfalls.
Collapse
|
580
|
Williams KA, Lang RM, Reba RC, Taillon LA. Comparison of technetium-99m sestamibi-gated tomographic perfusion imaging with echocardiography and electrocardiography for determination of left ventricular mass. Am J Cardiol 1996; 77:750-5. [PMID: 8651128 DOI: 10.1016/s0002-9149(97)89211-9] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
Left ventricular (LV) mass estimates obtained from post-stress gated single-photon emission computed tomographic (SPECT) perfusion images were compared with 2-dimensionally targeted M-mode echocardiograms and with resting electrocardiographic voltage in 32 patients with stress perfusion scans that were either normal or only mildly abnormal. Myocardial pixel volumes were obtained from SPECT transaxial slices at end-diastole, end-systole, and summed ("ungated") static reformatted SPECT images at 2 levels of background subtraction, 37.5% and 35% of peak myocardial activity. The S-wave amplitude in lead V1 and the R-wave amplitude in V5 were summed for an electrocardiographic index of voltage. Echocardiographic LV mass was calculated using the modified Penn convention formula. SPECT myocardial mass estimates were significantly greater at diastole when compared with systolic or summed images. There was a moderated, although highly significant, correlation between echocardiographic and SPECT indexes of LV mass with the lower (35%) background threshold (r = 0.59, 0.60, and 0.53 for diastole, summed, and systole, each p < 0.001). The diastolic SPECT estimate of LV mass correlation with electrocardiographic voltage (r = 0.56) was superior to the correlation between echocardiography and electrocardiography (r = 0.30). With use of published criteria for the presence of LV hypertrophy on echocardiography, diastolic and systolic gated SPECT predicted echocardiographic results with 78% accuracy.
Collapse
|
581
|
Mor-Avi V, Lang RM, Robinson KA, Korcarz C, Ng AF, Vignon P, Akselrod S, Shroff SG. Contrast echocardiographic quantification of regional myocardial perfusion: validation with an isolated rabbit heart model. J Am Soc Echocardiogr 1996; 9:156-65. [PMID: 8849611 DOI: 10.1016/s0894-7317(96)90023-1] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
Quantification of regional myocardial tissue blood flow (RMBF) based on contrast echocardiography has yet to be achieved. This study validated our recently proposed algorithm for quantification of RMBF with colored microspheres. Experiments were carried out in an isolated rabbit heart preparation (n = 11). Aortic root injections of perfluoropropane-filled albumin microsphere solution (FS069) and colored microspheres were performed at five levels of coronary flow achieved by altering perfusion pressure. During each injection of contrast material, consecutive end-diastolic images of the heart and an extracardiac reference chamber were acquired with a 7.5 MHz transducer and digitized. Time-intensity curves from the reference chamber and myocardial regions of interest, corresponding to the anatomic segments used for colored microsphere analysis, were analyzed for RMBF. Blood flow was calculated as the intravascular volume fraction (ratio of areas under myocardial and reference curves) divided by mean transit time (deconvolution of impulse response) and compared with those obtained with colored microspheres. Injections of FS069 resulted in highly reproducible enhancement of myocardial contrast. Analysis of time-intensity curves provided consistent measurements of RMBF (r = 0.91), which correlated highly with microsphere data (r = 0.84). The use of this new algorithm allows accurate quantification of RMBF in the isolated heart model. Further validation of this approach in an animal model with peripheral intravenous injections of contrast material will allow noninvasive clinical measurements of RMBF.
Collapse
|
582
|
Sorrentino MJ, Marcus RH, Lang RM. Left ventricular outflow tract obstruction as a cause for hypotension and symptoms during dobutamine stress echocardiography. Clin Cardiol 1996; 19:225-30. [PMID: 8674261 DOI: 10.1002/clc.4960190317] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Hypotension has been found to occur in more than one-third of patients during DBSE. Unlike traditional treadmill exercise stress testing, hypotension does not appear to be associated with significant coronary artery disease or left ventricular (LV) dysfunction. Several ischemic and nonischemic mechanisms such as dynamic LV intracavitary obstruction have been implicated in the pathogenesis of hypotension and the induction of symptoms during DBSE. HYPOTHESIS The purpose of this study was the prospective evaluation of patients referred for dobutamine stress echocardiography (DBSE) to determine (1) the frequency of hypotension during DBSE, (2) the underlying mechanisms responsible for the induction of hypotension, and (3) to describe the cardiac chamber sizes and mass of patients in whom hypotension occurs. METHODS Seventy-eight consecutive patients were studied during DBSE. Pulsed and continuous-wave Doppler echocardiography were performed at baseline and at each dobutamine infusion stage. Maximum velocities were recorded. Cardiac output was determined noninvasively at each stage in patients who developed an outflow tract gradient. Echocardiography was used to characterize LV dimensions and mass. RESULTS During dobutamine infusion, 14 of 78 (18%) patients developed a left ventricular outflow tract (LVOT) velocity > or = 2.5 m/s. Pulsed Doppler echocardiography verified that the maximal velocity originated in the LVOT. Of the patients who developed an LVOT gradient, 57% had a concomitant hypotensive response to dobutamine compared with 33% of patients without a gradient (not significant). Four of nine patients had a simultaneous fall in cardiac output. Patients who developed an LVOT gradient had smaller LV dimensions and increased wall thicknesses compared with those who did not develop a gradient. CONCLUSIONS Dobutamine stress echocardiography precipitates LVOT obstruction in certain patients. The development of a gradient corresponded with a fall in blood pressure and a decline in cardiac output in nearly half of the patients. These findings suggest that stress-induced LVOT obstruction may be responsible in part for the hemodynamic changes and symptoms experienced by these patients during exercise.
Collapse
|
583
|
Vignon P, Lagrange P, Boncoeur MP, Francois B, Gastinne H, Lang RM. Routine transesophageal echocardiography for the diagnosis of aortic disruption in trauma patients without enlarged mediastinum. THE JOURNAL OF TRAUMA 1996; 40:422-7. [PMID: 8601861 DOI: 10.1097/00005373-199603000-00017] [Citation(s) in RCA: 45] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
OBJECTIVE To assess the value of routine transesophageal echocardiography (TEE) in diagnosing traumatic disruption of the aorta (TDA) in trauma patients presenting without enlarged mediastinum on chest x-ray films. DESIGN Prospective study. MATERIALS AND METHODS TEE was routinely performed to exclude the presence of TDA in patients who sustained severe trauma secondary to abrupt deceleration collisions and presented with an upper mediastinum of fewer than 8 cm on supine chest x-ray films. Patients were divided into two groups according to the presence (group I) or absence (group II) of mediastinal hematoma diagnosed during TEE examination. Radiographic signs regarded as indicators of the presence of TDA were evaluated in both groups. RESULTS Among the 40 consecutive patients studied, TEE demonstrated two cases of TDA associated with a mediastinal hematoma that were confirmed by both aortography and surgery. One of the patients had a normal mediastinum on presentation chest x-ray films, and the other only exhibited a blurred aortic knob. Radiographic mediastinal abnormalities suggestive of TDA were observed in 13 patients, but chest x-ray films were unremarkable in 12 patients. Twenty patients had multiple rib fractures. The frequency of chest radiographic abnormalities was not significantly higher in group I (n = 6) when compared with group II patients (n = 34). TEE examination demonstrated a normal thoracic aorta in 35 patients and was nondiagnostic in 3 patients (normal aortography). CONCLUSION TEE should be routinely performed in victims of violent deceleration collisions, even in patients presenting apparently normal mediastinum on supine chest radiography.
Collapse
|
584
|
Poppas A, Sawyer R, Kinder C, Vignon P, Bednarz J, Lee BK, Feldman T, Glagov S, Lang RM. A 73-year-old man with hypertension and syncope. Circulation 1996; 93:380-6. [PMID: 8548913 DOI: 10.1161/01.cir.93.2.380] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
|
585
|
|
586
|
Krauss D, Weinert L, Lang RM. The Role of Multiplane Transesophageal Echocardiography in Diagnosing PDA in an Adult. Echocardiography 1996; 13:95-98. [PMID: 11442910 DOI: 10.1111/j.1540-8175.1996.tb00874.x] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
Abstract
The usefulness of multiplane transesophageal echocardiography in diagnosing PDA in asymptomatic adults is described. (ECHOCARDIOGRAPHY, Volume 13, January 1996)
Collapse
|
587
|
Vignon P, Guéret P, Vedrinne JM, Lagrange P, Cornu E, Abrieu O, Gastinne H, Bensaid J, Lang RM. Role of transesophageal echocardiography in the diagnosis and management of traumatic aortic disruption. Circulation 1995; 92:2959-68. [PMID: 7586266 DOI: 10.1161/01.cir.92.10.2959] [Citation(s) in RCA: 137] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
BACKGROUND Traumatic disruption of the aorta (TDA) is a life-threatening injury that requires rapid diagnosis and treatment. Emergency aortography, which is the current standard diagnostic imaging modality, is invasive, time-consuming, and difficult to perform in hemodynamically unstable patients with multiple trauma. We performed transesophageal echocardiography (TEE) in patients with suspected TDA to determine the diagnostic accuracy and impact on patient management of this alternative, portable imaging modality. METHODS AND RESULTS Thirty-two consecutive trauma patients (mean age, 40 +/- 16 years) with suspected TDA (violent deceleration accident and mediastinum > 8 cm on admission chest x-ray) prospectively underwent a TEE examination in the emergency room. Findings during TEE were compared with those encountered during aortography, surgery, or necropsy. Two subsets of traumatic aortic injuries with distinct echocardiographic signs were observed: (1) subadventitial TDA (n = 10) and (2) traumatic intimal tears (n = 3). Eighteen patients had normal TEE confirmed by aortography. One 2-mm medial tear was missed by TEE (necropsy). The sensitivity and specificity of TEE for the diagnosis of subadventitial TDA were 91% and 100%, respectively. Patients with subadventitial TDA were taken to surgery immediately, whereas patients with intimal aortic tears were treated conservatively. Eighteen patients (mean age, 57 +/- 15 years) with confirmed acute aortic dissection involving the aortic isthmus were also included to establish the echocardiographic differential diagnostic criteria between this entity and TDA. CONCLUSIONS TEE should be considered the first-line imaging modality for the evaluation of trauma patients with suspected injuries of the thoracic aorta because of its portability, safety, diagnostic accuracy, and potential impact on patient management.
Collapse
|
588
|
Abstract
Congestive heart failure is an uncommon complication of pregnancy with potentially life-threatening consequences. Peripartum cardiomyopathy is a disease of unknown cause in which severe left ventricular dysfunction occurs during late pregnancy or the early puerperium. In the past, the diagnosis of this entity was made on clinical grounds; however, modern echocardiographic techniques have allowed more accurate diagnoses by excluding cases of diseases that mimic the clinical symptoms and signs of heart failure. Risk factors for peripartum cardiomyopathy include advanced maternal age, multiparity, African descent, twinning, and long-term tocolysis. An extensive search for the causes of peripartum cardiomyopathy has been unrevealing. Treatment includes digitalis, diuretic agents, and vasodilators. Anticoagulation is strongly recommended, especially if ventricular function is persistent. The prognosis of peripartum cardiomyopathy is related to the recovery of ventricular function. Caution is advised in recommending subsequent pregnancy, especially if left ventricular dysfunction is persistent.
Collapse
|
589
|
Mor-Avi V, Gillesberg IE, Korcarz C, Sandelski J, Lang RM. Improved quantification of left ventricular function by applying signal averaging to echocardiographic acoustic quantification. J Am Soc Echocardiogr 1995; 8:679-89. [PMID: 9417211 DOI: 10.1016/s0894-7317(05)80382-7] [Citation(s) in RCA: 25] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
The acoustic quantification technique for on-line detection of endocardial boundaries currently provides continuous left ventricular area or volume signals and beat-to-beat ejection fraction. However, the distortion of individual waveforms by noise results in a wide beat-to-beat variability in these parameters. We developed an automated algorithm for the evaluation of left ventricular function by averaging acoustic quantification signals. End-diastolic and end-systolic area, stroke area, and fractional area change are measured directly from the average waveform. Peak ejection and peak filling rates and time to peak filling rate are obtained from its time derivative. Area signals obtained from eight normal subjects were used to evaluate the performance of this algorithm. Parameters of left ventricular function obtained with the automated algorithm were highly consistent and in excellent agreement with those obtained by repeated manual operator-dependent selections. This algorithm provides a fast and easy method for noise reduction in acoustic quantification signals, which significantly improves the noninvasive assessment of left ventricular function.
Collapse
|
590
|
Shroff SG, Berger DS, Korcarz C, Lang RM, Marcus RH, Miller DE. Physiological relevance of T-tube model parameters with emphasis on arterial compliances. THE AMERICAN JOURNAL OF PHYSIOLOGY 1995; 269:H365-74. [PMID: 7631869 DOI: 10.1152/ajpheart.1995.269.1.h365] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
The T-tube model of systemic arterial circulation was examined with respect to the physiological relevance of model parameters. root aortic pressure [Pao(t)] and flow [Qao(t)] and descending aortic flow [Qb(t)] were measured in anesthetized, open-chest dogs under control conditions, during inflation of a balloon positioned in the left external iliac artery (n = 5), and during infusion of vasoactive drugs nitroprusside (NTP, n = 4) and phenylephrine (PHL, n = 5). With Pao(t) as the input, the model accurately predicted both Qao(t) and Qb(t) under all conditions (r2 > 0.96). The balloon inflation data established the ability of the model to discriminate between proximal and distal arterial mechanical properties. Furthermore, proximal properties (i.e., tube characteristic impedances and transit times) were independent of distal properties such as terminal compliances and resistances (or equivalently, wave reflections). The effects of NTP and PHL were pharmacologically consistent and served to further validate this model. NTP primarily affected distal (load) properties, whereas PHL altered both load and tube parameters. Physiological interpretation of model parameters, particularly compliance, is also discussed. The ability of the model to correctly discriminate between proximal and distal arterial properties is relevant because these properties may affect cardiovascular function differently.
Collapse
|
591
|
Krauss D, Marcus RH, Weinert L, Korcarz C, Lang RM. Diastolic intraventricular pressure gradient in symmetric left ventricular hypertrophy. Am Heart J 1995; 130:178-80. [PMID: 7611111 DOI: 10.1016/0002-8703(95)90255-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
|
592
|
Cholley BP, Lang RM, Berger DS, Korcarz C, Payen D, Shroff SG. Alterations in systemic arterial mechanical properties during septic shock: role of fluid resuscitation. THE AMERICAN JOURNAL OF PHYSIOLOGY 1995; 269:H375-84. [PMID: 7631871 DOI: 10.1152/ajpheart.1995.269.1.h375] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
The effects of septic shock (endotoxin; EDTX) on arterial mechanical properties were studied in anesthetized rabbits, both in the absence (EDTX alone) and presence (EDTX + fluids) of fluid resuscitation. Aortic pressure-flow (n = 20) and pressure-diameter (n = 10) measurements were used to calculate systemic arterial and regional aortic mechanical properties. At 3 h of EDTX shock, EDTX-alone rabbits had elevated total peripheral resistance (TPR, + 30%, P < 0.05), reduced cardiac output (CO, -40%, P < 0.05), and increased aortic characteristic impedance (Zc, +78%, P < 0.05). In contrast, the EDTX + fluids group responded with decreased TPR (-30%, P < 0.05), a tendency to increase CO (+23%), and elevated Zc (+46%, P < 0.05). A reduction in aortic diameter (-20%, P < 0.05) and an increase in elastic modulus (+50%, P < 0.05) and water content (+23%, P < 0.02) of the aortic wall were observed following endotoxemia. Thus following EDTX 1) "hyperdynamic" septic shock profile (i.e., low TPR, high CO) was observed only when concomitant fluid replacement was provided, 2) aortic wall stiffening was present due to both increased smooth muscle tone and vessel wall edema, and 3) fluid resuscitation resulted in discordant changes in TPR and Zc, suggesting differential flow-induced vasodilation between arteriolar and aortic smooth muscle.
Collapse
|
593
|
Lang RM, Marcus RH. Images in clinical medicine. Ostium secundum atrial septal defect. N Engl J Med 1995; 332:1337. [PMID: 7715643 DOI: 10.1056/nejm199505183322005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
|
594
|
Mor-Avi V, Weinert L, Roberts LB, Koch R, Prater D, Lang RM. Analysis of the temporal patterns of systolic contraction using acoustic quantification color kinesis. J Am Soc Echocardiogr 1995. [DOI: 10.1016/s0894-7317(05)80240-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
595
|
Bednarz JE, Marcus RH, Lang RM. Technical guidelines for performing automated border detection studies. J Am Soc Echocardiogr 1995; 8:293-305. [PMID: 7640023 DOI: 10.1016/s0894-7317(05)80040-9] [Citation(s) in RCA: 72] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
|
596
|
Davila-Roman VG, Shroff SG, Korcarz C, Bednarz J, Braverman A, Bosner M, Lang RM. Noninvasive assessment of arterial properties in marfan syndrome using transesophageal echocardiography with automated border detection and subclavian pulse tracings. J Am Soc Echocardiogr 1995. [DOI: 10.1016/s0894-7317(05)80202-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
597
|
Vignon P, Lang RM, Lagrange P, François B, Gastinne H, Gay R. Differential echocardiographic diagnosis between subadventitial traumatic disruption and acute dissection of the thoracic aorta. J Am Soc Echocardiogr 1995. [DOI: 10.1016/s0894-7317(05)80168-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
|
598
|
Vignon P, Lagrange P, Boncoeur MP, François B, Gastinne H, Lang RM. Should transesophageal echocardiography be performed routinely in trauma patients with suspected aortic disruption irrespective of the width of the mediastinum on admission chest X-ray? J Am Soc Echocardiogr 1995. [DOI: 10.1016/s0894-7317(05)80106-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
599
|
Mor-Avi V, Lang RM. Effects of temperature on the stability of FS069, a second generation echocardiographic contrast agent. J Am Soc Echocardiogr 1995. [DOI: 10.1016/s0894-7317(05)80125-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
600
|
Cholley BP, Shroff SG, Sandelski J, Korcarz C, Balasia BA, Jain S, Berger DS, Murphy MB, Marcus RH, Lang RM. Differential effects of chronic oral antihypertensive therapies on systemic arterial circulation and ventricular energetics in African-American patients. Circulation 1995; 91:1052-62. [PMID: 7850941 DOI: 10.1161/01.cir.91.4.1052] [Citation(s) in RCA: 39] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/17/1994] [Accepted: 10/02/1994] [Indexed: 01/27/2023]
Abstract
BACKGROUND A comprehensive evaluation of arterial load characteristics and left ventricular energetics in systemic hypertension has been limited by the need for invasive techniques to access instantaneous aortic pressure and flow. As a consequence of this methodological limitation, no data exist on the effects of long-term antihypertensive therapy on global arterial impedance properties and indexes of myocardial oxygen consumption (MVO2). Using recently validated noninvasive techniques, we compared in hypertensive patients the effects of chronic oral treatment with ramipril, nifedipine, and atenolol on arterial impedance and mechanical power dissipation as well as indexes of MVO2. METHODS AND RESULTS Sixteen African-American subjects with systemic hypertension were studied with a randomized, double-blind, crossover protocol. Instantaneous central aortic pressure and flow, from which arterial load characteristics can be derived, were estimated from calibrated subclavian pulse tracings (SPTs) and continuous-wave aortic Doppler velocity in conjunction with two-dimensional (2D) echocardiographic measurements of the aortic annulus, respectively. To derive ventricular wall stress and indexes of MVO2, left ventricular short- (M-mode) and long-axis (2D echo) images were acquired simultaneously with SPTs. Data were collected at the end of a 2-week washout period (predrug control) and after 6 weeks of treatment with each agent. Although all three agents reduced diastolic blood pressure to the same extent, different effects on mean and systolic pressures and vascular impedance properties were noted. Nifedipine reduced total peripheral resistance (TPR; 1744 +/- 398 versus 1290 +/- 215 dyne-s/cm5) and increased arterial compliance (ACL; 1.234 +/- 0.253 versus 1.776 +/- 0.415 mL/mm Hg). This improvement in arterial compliance was not entirely accounted for by the reduction in distending pressure. Ramipril also decreased TPR (1740 +/- 292 versus 1437 +/- 290 dyne-s/cm5) and increased ACL (1.214 +/- 0.190 versus 1.569 +/- 0.424 mL/mm Hg), but with this agent, the change in arterial compliance was explained solely on the basis of a reduction in distending pressure. Atenolol, in contrast, did not affect either TPR or ACL. In agreement with the compliance results, nifedipine and ramipril significantly lowered the first two harmonics of the impedance spectrum, but atenolol did not. None of these agents resulted in a significant change in characteristic impedance or in the relative amplitude of the reflected pressure wave. Total vascular mechanical power and percent of oscillatory power remained unaltered with all antihypertensive treatments. Only ramipril and nifedipine reduced the integral of both meridional and circumferential systolic wall stresses, indicating that MVO2 per beat was reduced with these agents. Stress-time index, a measure of MVO2 per unit time, decreased significantly with ramipril but not with nifedipine because of an increase in heart rate noted in 10 of 16 patients (mean increase, 10 beats per minute). Thus, a reduction in MVO2 coupled with unchanged total vascular mechanical power suggests improved efficiency of ventriculoarterial coupling with ramipril and with nifedipine in the subset of patients in whom heart rate remained unchanged. In contrast, there was no evidence of a reduction in wall stress, stress integral, or stress-time index with atenolol. CONCLUSIONS The noninvasive methodology used in this study constitutes a new tool for serial and simultaneous evaluation of arterial hemodynamics and left ventricular energetics in systemic hypertension. In this study, we demonstrate the differential effects of chronic antihypertensive therapies on systemic arterial circulation and indexes of MVO2 in African-American subjects. Consideration of drug-induced differential responses of arterial load and indexes of MVO2 with each drug may provide a more physiological approach to the treatment of systemic hypertension in indivi
Collapse
|