Kumar S, Sahore V, Rogers CI, Woolley AT. Development of an integrated microfluidic solid-phase extraction and electrophoresis device. Analyst 2017; 141:1660-8. [PMID: 26820409 DOI: 10.1039/c5an02352a] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
Abstract
This study focuses on the design and fabrication of a microfluidic platform that integrates solid-phase extraction (SPE) and microchip electrophoresis (μCE) on a single device. The integrated chip is a multi-layer structure consisting of polydimethylsiloxane valves with a peristaltic pump, and a porous polymer monolith in a thermoplastic layer. The valves and pump are fabricated using soft lithography to enable pressure-based fluid actuation. A porous polymer monolith column is synthesized in the SPE unit using UV photopolymerization of a mixture consisting of monomer, cross-linker, photoinitiator, and porogens. The hydrophobic, porous structure of the monolith allows protein retention with good through flow. The functionality of the integrated device in terms of pressure-controlled flow, protein retention and elution, on-chip enrichment, and separation is evaluated using ferritin (Fer). Fluorescently labeled Fer is enriched ∼80-fold on a reversed-phase monolith from an initial concentration of 100 nM. A five-valve peristaltic pump produces higher flow rates and a narrower Fer elution peak than a three-valve pump operated under similar conditions. Moreover, the preconcentration capability of the SPE unit is demonstrated through μCE of enriched Fer and two model peptides in the integrated system. FA, GGYR, and Fer are concentrated 4-, 12-, and 50-fold, respectively. The loading capacity of the polymer monolith is 56 fmol (25 ng) for Fer. This device lays the foundation for integrated systems that can be used to analyze various disease biomarkers.
Collapse
|
52
|
Sonker M, Yang R, Sahore V, Kumar S, Woolley AT. On-Chip Fluorescent Labeling using Reversed-phase Monoliths and Microchip Electrophoretic Separations of Selected Preterm Birth Biomarkers. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2016; 8:7739-7746. [PMID: 28496521 PMCID: PMC5421993 DOI: 10.1039/c6ay01803c] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
On-chip preconcentration, purification, and fluorescent labeling are desirable sample preparation steps to achieve complete automation in integrated microfluidic systems. In this work, we developed electrokinetically operated microfluidic devices for solid-phase extraction and fluorescent labeling of preterm birth (PTB) biomarkers. Reversed-phase monoliths based on different acrylate monomers were photopolymerized in cyclic olefin copolymer microdevices and studied for the selective retention and elution of a fluorescent dye and PTB biomarkers. Octyl methacrylate-based monoliths with desirable retention and elution characteristics were chosen and used for on-chip fluorescent labeling of three PTB biomarkers. Purification of on-chip labeled samples was done by selective elution of unreacted dye prior to sample. Automated and rapid on-chip fluorescent labeling was achieved with similar efficiency to that obtained for samples labeled off chip. Additionally, protocols for microchip electrophoresis of several off-chip-labeled PTB biomarkers were demonstrated in poly(methyl methacrylate) microfluidic devices. This study is an important step toward the development of integrated on-chip labeling and separation microfluidic devices for PTB biomarkers.
Collapse
|
53
|
Gong H, Woolley AT, Nordin GP. High density 3D printed microfluidic valves, pumps, and multiplexers. LAB ON A CHIP 2016; 16:2450-8. [PMID: 27242064 PMCID: PMC4917409 DOI: 10.1039/c6lc00565a] [Citation(s) in RCA: 119] [Impact Index Per Article: 14.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
In this paper we demonstrate that 3D printing with a digital light processor stereolithographic (DLP-SLA) 3D printer can be used to create high density microfluidic devices with active components such as valves and pumps. Leveraging our previous work on optical formulation of inexpensive resins (RSC Adv., 2015, 5, 106621), we demonstrate valves with only 10% of the volume of our original 3D printed valves (Biomicrofluidics, 2015, 9, 016501), which were already the smallest that have been reported. Moreover, we show that incorporation of a thermal initiator in the resin formulation along with a post-print bake can dramatically improve the durability of 3D printed valves up to 1 million actuations. Using two valves and a valve-like displacement chamber (DC), we also create compact 3D printed pumps. With 5-phase actuation and a 15 ms phase interval, we obtain pump flow rates as high as 40 μL min(-1). We also characterize maximum pump back pressure (i.e., maximum pressure the pump can work against), maximum flow rate (flow rate when there is zero back pressure), and flow rate as a function of the height of the pump outlet. We further demonstrate combining 5 valves and one DC to create a 3-to-2 multiplexer with integrated pump. In addition to serial multiplexing, we also show that the device can operate as a mixer. Importantly, we illustrate the rapid fabrication and test cycles that 3D printing makes possible by implementing a new multiplexer design to improve mixing, and fabricate and test it within one day.
Collapse
|
54
|
Knob R, Sahore V, Sonker M, Woolley AT. Advances in monoliths and related porous materials for microfluidics. BIOMICROFLUIDICS 2016; 10:032901. [PMID: 27190564 PMCID: PMC4859832 DOI: 10.1063/1.4948507] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/05/2016] [Accepted: 04/20/2016] [Indexed: 05/06/2023]
Abstract
In recent years, the use of monolithic porous polymers has seen significant growth. These materials present a highly useful support for various analytical and biochemical applications. Since their introduction, various approaches have been introduced to produce monoliths in a broad range of materials. Simple preparation has enabled their easy implementation in microchannels, extending the range of applications where microfluidics can be successfully utilized. This review summarizes progress regarding monoliths and related porous materials in the field of microfluidics between 2010 and 2015. Recent developments in monolith preparation, solid-phase extraction, separations, and catalysis are critically discussed. Finally, a brief overview of the use of these porous materials for analysis of subcellular and larger structures is given.
Collapse
|
55
|
Gong H, Beauchamp M, Perry S, Woolley AT, Nordin GP. Optical Approach to Resin Formulation for 3D Printed Microfluidics. RSC Adv 2015; 5:106621-106632. [PMID: 26744624 DOI: 10.1039/c5ra23855b] [Citation(s) in RCA: 125] [Impact Index Per Article: 13.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022] Open
Abstract
Microfluidics imposes different requirements on 3D printing compared to many applications because the critical features for microfluidics consist of internal microvoids. Resins for general 3D printing applications, however, are not necessarily formulated to meet the requirements of microfluidics and minimize the size of fabricated voids. In this paper we use an optical approach to guide custom formulation of resins to minimize the cross sectional size of fabricated flow channels as exemplars of such voids. We focus on stereolithgraphy (SL) 3D printing with Digital Light Processing (DLP) based on a micromirror array and use a commercially available 3D printer. We develop a mathematical model for the optical dose delivered through the thickness of a 3D printed part, including the effect of voids. We find that there is a fundamental trade-off between the homogeneity of the optical dose within individual layers and how far the critical dose penetrates into a flow channel during fabrication. We also experimentally investigate the practical limits of flow channel miniaturization given the optical properties of a resin and find that the minimum flow channel height is ~3.5-5.5ha where ha is the optical penetration depth of the resin, and that the minimum width is 4 pixels in the build plane. We also show that the ratio of the build layer thickness to ha should be in the range 0.3-1.0 to obtain the minimum flow channel height for a given resin. The minimum flow channel size that we demonstrate for a custom resin is 60 μm × 108 μm for a 10 μm build layer thickness. This work lays the foundation for 3D printing of <100 μm microfluidic features.
Collapse
|
56
|
Sahore V, Kumar S, Rogers CI, Jensen JK, Sonker M, Woolley AT. Pressure-actuated microfluidic devices for electrophoretic separation of pre-term birth biomarkers. Anal Bioanal Chem 2015; 408:599-607. [PMID: 26537925 DOI: 10.1007/s00216-015-9141-0] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2015] [Revised: 10/07/2015] [Accepted: 10/21/2015] [Indexed: 12/13/2022]
Abstract
We have developed microfluidic devices with pressure-driven injection for electrophoretic analysis of amino acids, peptides, and proteins. The novelty of our approach lies in the use of an externally actuated on-chip peristaltic pump and closely spaced pneumatic valves that allow well-defined, small-volume sample plugs to be injected and separated by microchip electrophoresis. We fabricated three-layer poly(dimethylsiloxane) (PDMS) microfluidic devices. The fluidic layer had injection and separation channels, and the control layer had an externally actuated on-chip peristaltic pump and four pneumatic valves around the T-intersection to carry out sample injection. An unpatterned PDMS membrane layer was sandwiched between the fluidic and control layers as the actuated component in pumps and valves. Devices with the same peristaltic pump design but different valve spacings (100, 200, 300, and 400 μm) from the injection intersection were fabricated using soft lithographic techniques. Devices were characterized through fluorescent imaging of captured plugs of a fluorescein-labeled amino acid mixture and through microchip electrophoresis separations. A suitable combination of peak height, separation efficiency, and analysis time was obtained with a peristaltic pump actuation rate of 50 ms, an injection time of 30 s, and a 200-μm valve spacing. We demonstrated the injection of samples in different solutions and were able to achieve a 2.4-fold improvement in peak height and a 2.8-fold increase in separation efficiency though sample stacking. A comparison of pressure-driven injection and electrokinetic injection with the same injection time and separation voltage showed a 3.9-fold increase in peak height in pressure-based injection with comparable separation efficiency. Finally, the microchip systems were used to separate biomarkers implicated in pre-term birth. Although these devices have initially been demonstrated as a stand-alone microfluidic separation tool, they have strong potential to be integrated within more complex systems.
Collapse
|
57
|
Pagaduan JV, Sahore V, Woolley AT. Applications of microfluidics and microchip electrophoresis for potential clinical biomarker analysis. Anal Bioanal Chem 2015; 407:6911-22. [PMID: 25855148 DOI: 10.1007/s00216-015-8622-5] [Citation(s) in RCA: 46] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2015] [Revised: 02/20/2015] [Accepted: 03/05/2015] [Indexed: 10/23/2022]
Abstract
This article reviews advances over the last five years in microfluidics and microchip-electrophoresis techniques for detection of clinical biomarkers. The variety of advantages of miniaturization compared with conventional benchtop methods for detecting biomarkers has resulted in increased interest in developing cheap, fast, and sensitive techniques. We discuss the development of applications of microfluidics and microchip electrophoresis for analysis of different clinical samples for pathogen identification, personalized medicine, and biomarker detection. We emphasize the advantages of microfluidic techniques over conventional methods, which make them attractive future diagnostic tools. We also discuss the versatility and adaptability of this technology for analysis of a variety of biomarkers, including lipids, small molecules, carbohydrates, nucleic acids, proteins, and cells. Finally, we conclude with a discussion of aspects that need to be improved to move this technology towards routine clinical and point-of-care applications.
Collapse
|
58
|
Pagaduan JV, Ramsden M, O'Neill K, Woolley AT. Microchip immunoaffinity electrophoresis of antibody-thymidine kinase 1 complex. Electrophoresis 2015; 36:813-7. [PMID: 25486911 PMCID: PMC4346389 DOI: 10.1002/elps.201400436] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2014] [Revised: 11/12/2014] [Accepted: 11/27/2014] [Indexed: 11/12/2022]
Abstract
Thymidine kinase 1 (TK1) is an important cancer biomarker whose serum levels are elevated in early cancer development. We developed a microchip electrophoresis immunoaffinity assay to measure recombinant purified TK1 (pTK1) using an antibody (Ab) that binds to human TK1. We fabricated PMMA microfluidic devices to test the feasibility of detecting Ab-pTK1 immune complexes as a step toward TK1 analysis in clinical serum samples. We were able to separate immune complexes from unbound Abs using 0.5× PBS (pH 7.4) containing 0.01% Tween-20, with 1% w/v methylcellulose that acts as a dynamic surface coating and sieving matrix. Separation of the Ab and Ab-pTK1 complex was observed within a 5 mm effective separation length. This method of detecting pTK1 is easy to perform, requires only a 10 μL sample volume, and takes just 1 min for separation.
Collapse
|
59
|
Rogers CI, Qaderi K, Woolley AT, Nordin GP. 3D printed microfluidic devices with integrated valves. BIOMICROFLUIDICS 2015; 9:016501. [PMID: 25610517 PMCID: PMC4297278 DOI: 10.1063/1.4905840] [Citation(s) in RCA: 147] [Impact Index Per Article: 16.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/11/2014] [Accepted: 12/30/2014] [Indexed: 05/04/2023]
Abstract
We report the successful fabrication and testing of 3D printed microfluidic devices with integrated membrane-based valves. Fabrication is performed with a low-cost commercially available stereolithographic 3D printer. Horizontal microfluidic channels with designed rectangular cross sectional dimensions as small as 350 μm wide and 250 μm tall are printed with 100% yield, as are cylindrical vertical microfluidic channels with 350 μm designed (210 μm actual) diameters. Based on our previous work [Rogers et al., Anal. Chem. 83, 6418 (2011)], we use a custom resin formulation tailored for low non-specific protein adsorption. Valves are fabricated with a membrane consisting of a single build layer. The fluid pressure required to open a closed valve is the same as the control pressure holding the valve closed. 3D printed valves are successfully demonstrated for up to 800 actuations.
Collapse
|
60
|
Chatterjee D, Mansfield DS, Woolley AT. MICROFLUIDIC DEVICES FOR LABEL-FREE AND NON-INSTRUMENTED QUANTITATION OF UNAMPLIFIED NUCLEIC ACIDS BY FLOW DISTANCE MEASUREMENT. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2014; 6:8173-8179. [PMID: 25530814 PMCID: PMC4269297 DOI: 10.1039/c4ay01845a] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
Timely biomarker quantitation has potential to improve human health but current methods have disadvantages either in terms of cost and complexity for benchtop instruments, or reduced performance in quantitation and/or multiplexing for point-of-care systems. We previously developed microfluidic devices wherein visually observed flow distances correlated with a model analyte's concentration.1 Here, we significantly expand over this prior result to demonstrate the measurement of unamplified DNA analogues of microRNAs (miRNAs), biomarkers whose levels can be altered in disease states. We have developed a method for covalently attaching nucleic acid receptors on poly(dimethylsiloxane) microchannel surfaces by silane and cross-linker treatments. We found a flow distance dependence on target concentrations from 10 μg/mL to 10 pg/mL for DNA in both buffer and synthetic urine. Moreover, flow time in addition to flow distance is correlated with target concentration. We also observed longer flow distances for single-base mismatches compared to the target sequence at the same concentration, indicating that our approach can be used to detect point mutations. Finally, experiments with DNA analogues of miRNA biomarkers for kidney disease (mir-200c-3p) and prostate cancer (mir-107) in synthetic urine showed the ability to detect these analytes near clinically relevant levels. Our results demonstrate that these novel microfluidic assays offer a simple route to sensitive, amplification-free nucleic acid quantitation, with strong potential for point-of-care application.
Collapse
|
61
|
Yang R, Pagaduan JV, Yu M, Woolley AT. On chip preconcentration and fluorescence labeling of model proteins by use of monolithic columns: device fabrication, optimization, and automation. Anal Bioanal Chem 2014; 407:737-47. [PMID: 25012353 DOI: 10.1007/s00216-014-7988-0] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2014] [Revised: 06/16/2014] [Accepted: 06/20/2014] [Indexed: 12/20/2022]
Abstract
Microfluidic systems with monolithic columns have been developed for preconcentration and on-chip labeling of model proteins. Monoliths were prepared in microchannels by photopolymerization, and their properties were optimized by varying the composition and concentration of the monomers to improve flow and extraction. On-chip labeling of proteins was achieved by driving solutions through the monolith by use of voltage then incubating fluorescent dye with protein retained on the monolith. Subsequently, the labeled proteins were eluted, by applying voltages to reservoirs on the microdevice, and then detected, by monitoring laser-induced fluorescence. Monoliths prepared from octyl methacrylate combine the best protein retention with the possibility of separate elution of unattached fluorescent label with 50% acetonitrile. Finally, automated on-chip extraction and fluorescence labeling of a model protein were successfully demonstrated. This method involves facile sample pretreatment, and therefore has potential for production of integrated bioanalysis microchips.
Collapse
|
62
|
Gates EP, Dearden AM, Woolley AT. DNA‐templated lithography and nanofabrication for the fabrication of nanoscale electronic circuitry. Crit Rev Anal Chem 2014; 44:354-70. [DOI: 10.1080/10408347.2014.910636] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
|
63
|
Uprety B, Gates EP, Geng Y, Woolley AT, Harb JN. Site-specific metallization of multiple metals on a single DNA origami template. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2014; 30:1134-1141. [PMID: 24410066 DOI: 10.1021/la403617r] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
This work examines the selective deposition of two different metals on a single DNA origami template that was designed and assembled to direct the deposition. As a result, we were able to direct copper and gold to predesignated locations on the template, as verified by both compositional and morphological data, to form a heterogeneous Cu-Au junction. Seeding and deposition were performed in sequential steps. An enabling aspect of this work was the use of an organic layer or "chemical mask" to prevent unwanted deposition during the deposition of the second metal. In light of recent efforts in the field, the ability to localize components of different composition and structure to specific sections of a DNA template represents an important step forward in the fabrication of nanostructures based on DNA templates.
Collapse
|
64
|
Rogers CI, Oxborrow JB, Anderson RR, Tsai LF, Nordin GP, Woolley AT. Microfluidic Valves Made From Polymerized Polyethylene Glycol Diacrylate. SENSORS AND ACTUATORS. B, CHEMICAL 2014; 191:10.1016/j.snb.2013.10.008. [PMID: 24357897 PMCID: PMC3864702 DOI: 10.1016/j.snb.2013.10.008] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
Pneumatically actuated, non-elastomeric membrane valves fabricated from polymerized polyethylene glycol diacrylate (poly-PEGDA) have been characterized for temporal response, valve closure, and long-term durability. A ~100 ms valve opening time and a ~20 ms closure time offer valve operation as fast as 8 Hz with potential for further improvement. Comparison of circular and rectangular valve geometries indicates that the surface area for membrane interaction in the valve region is important for valve performance. After initial fabrication, the fluid pressure required to open a closed circular valve is ~50 kPa higher than the control pressure holding the valve closed. However, after ~1000 actuations to reconfigure polymer chains and increase elasticity in the membrane, the fluid pressure required to open a valve becomes the same as the control pressure holding the valve closed. After these initial conditioning actuations, poly-PEGDA valves show considerable robustness with no change in effective operation after 115,000 actuations. Such valves constructed from non-adsorptive poly-PEGDA could also find use as pumps, for application in small volume assays interfaced with biosensors or impedance detection, for example.
Collapse
|
65
|
Kumar S, Xuan J, Lee ML, Tolley HD, Hawkins AR, Woolley AT. Thin-film microfabricated nanofluidic arrays for size-selective protein fractionation. LAB ON A CHIP 2013; 13:4591-4598. [PMID: 24100699 PMCID: PMC3864585 DOI: 10.1039/c3lc50869b] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
Size-selective fractionation and quantitation of biostructures in the sub-hundred nanometer size range is an important research area. Unfortunately, current methods for size fractionation are complex, time consuming, or offer poor resolution. Using standard microfabrication technology, we developed a nanofluidic sieving system to address these limitations. Our setup consists of an array of parallel nanochannels with a height step in each channel, an injection reservoir, and a waste reservoir. The height steps can size fractionate a protein mixture as a solution flows through the nanochannels via capillary action. We tested this system with different sizes and concentrations of five proteins to understand protein size and height step effects on trapping. Our results clearly show size-dependent trapping of proteins at nanometer-scale height steps in nanochannels. We also developed a model that predicts the observed size-dependent trapping of proteins. This work is a key step towards scalable nanofluidic methods for molecular fractionation.
Collapse
|
66
|
Liu J, Uprety B, Gyawali S, Woolley AT, Myung NV, Harb JN. Fabrication of DNA-templated Te and Bi2Te3 nanowires by galvanic displacement. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2013; 29:11176-11184. [PMID: 23901791 DOI: 10.1021/la402678j] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
This paper demonstrates the use of galvanic displacement to form continuous tellurium-based nanowires on DNA templates, enabling the conversion of metals, which can be deposited site-specifically, into other materials needed for device fabrication. Specifically, galvanic displacement reaction of copper and nickel nanowires is used to fabricate tellurium and bismuth telluride nanowires on λ-DNA templates. The method is simple, rapid, highly selective, and applicable to a number of different materials. In this study, continuous Ni and Cu nanowires are formed on DNA templates by seeding with Ag followed by electroless plating of the desired metal. These wires are then displaced by a galvanic displacement reaction where either Te or Bi2Te3 is deposited from an acidic solution containing HTeO2(+) ions or a combination of HTeO2(+) and Bi(3+) ions, and the metal wire is simultaneously dissolved due to oxidation. Both tellurium and bismuth telluride wires can be formed from nickel templates. In contrast, copper templates only form tellurium nanowires under the conditions considered. Therefore, the composition of the metal being displaced can be used to influence the chemistry of the resulting nanowire. Galvanic displacement of metals deposited on DNA templates has the potential to enable site-specific fabrication of a variety of materials and, thereby, make an important contribution to the advancement of useful devices via self-assembled nanotemplates.
Collapse
|
67
|
Nge PN, Rogers CI, Woolley AT. Advances in microfluidic materials, functions, integration, and applications. Chem Rev 2013; 113:2550-83. [PMID: 23410114 PMCID: PMC3624029 DOI: 10.1021/cr300337x] [Citation(s) in RCA: 504] [Impact Index Per Article: 45.8] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
68
|
Gao C, Sun X, Woolley AT. Fluorescent measurement of affinity binding between thrombin and its aptamers using on-chip affinity monoliths. J Chromatogr A 2013; 1291:92-6. [PMID: 23587316 DOI: 10.1016/j.chroma.2013.03.063] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2013] [Revised: 03/24/2013] [Accepted: 03/25/2013] [Indexed: 10/27/2022]
Abstract
A microfluidic chip with integrated 2mm long monoliths incorporated with poly(ethylene glycol) (PEG) groups was developed for thrombin-aptamer interaction study. The non-G quartet forming oligonucleotide coated monoliths was compared to a 15 mer thrombin-binding aptamer, in which affinity binding and elution processes were real-time monitored fluorescently. The results showed that the fluorescence intensity of aptamer stationary phase is approximately 10 times higher than that of the control column, which is probably due to the successful suppression of nonspecific adsorption between thrombin and aptamers/monoliths by using PEG-monolith. The experiment was repeated using human serum albumin (HSA) and green fluorescence protein (GFP) as interferences, it was double confirmed that thrombin was selectively retained by PEG-monolith. An elution efficiency of 75% was achieved with an elute of 200mM acetic acid and 2M NaCI, and the eluted thrombin was successfully separated in an ionic buffer system of 20mM NaHCO3 (pH 9.5) with 3% PEG. The hydrophilic and antifouling properties of PEG-monolith greatly decrease nonspecific adsorption and enhance detection sensitivity, which provided an alternative method to perform on-chip fluorescent measurement of bioaffinity binding.
Collapse
|
69
|
Geng Y, Pearson AC, Gates EP, Uprety B, Davis RC, Harb JN, Woolley AT. Electrically conductive gold- and copper-metallized DNA origami nanostructures. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2013; 29:3482-3490. [PMID: 23419143 DOI: 10.1021/la305155u] [Citation(s) in RCA: 46] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
This work demonstrates the use of a circuit-like DNA origami structure as a template to fabricate conductive gold and copper nanostructures on Si surfaces. We improved over previous results by using multiple Pd seeding steps to increase seed uniformity and density. Our process has also been characterized through atomic force microscopy, particle size distribution analysis, and scanning electron microscopy. We found that four successive Pd seeding steps yielded the best results for electroless metal plating on DNA origami. Electrical resistance measurements were done on both Au- and Cu-metallized nanostructures, with each showing ohmic behavior. Gold-plated DNA origami structures made under optimal conditions had an average resistivity of 7.0 × 10(-5) Ω·m, whereas copper-metallized structures had a resistivity as low as 3.6 × 10(-4) Ω·m. Importantly, this is the first demonstration of electrically conductive Cu nanostructures fabricated on either DNA or DNA origami templates. Although resistivities for both gold and copper samples were larger than those of the bulk metal, these metal nanostructures have the potential for use in electrically connecting small structures. In addition, these metallized objects might find use in surface-enhanced Raman scattering experiments.
Collapse
|
70
|
Nge PN, Pagaduan JV, Yang W, Woolley AT. Integrated affinity and electrophoresis systems for multiplexed biomarker analysis. Methods Mol Biol 2013; 919:189-201. [PMID: 22976102 DOI: 10.1007/978-1-62703-029-8_18] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
The integration of affinity columns in microfluidic devices generates a micro-total analysis system which has high value in applications such as analyte extraction and preconcentration. In this chapter we describe the preparation of affinity columns in situ by photopolymerization of acrylate monomers. The epoxy groups on the columns are further functionalized with antibodies to form affinity columns. We describe in detail the use of our affinity columns in extracting cancer biomarkers from model mixtures and blood serum. The purified biomarkers are then eluted from the column, separated by microchip capillary electrophoresis, and detected by laser-induced fluorescence. Our procedures allow efficient sample pretreatment and preconcentration, as well as simultaneous and rapid quantification of multiple biomarkers.
Collapse
|
71
|
Nge PN, Pagaduan JV, Yu M, Woolley AT. Microfluidic chips with reversed-phase monoliths for solid phase extraction and on-chip labeling. J Chromatogr A 2012; 1261:129-35. [PMID: 22995197 PMCID: PMC3463737 DOI: 10.1016/j.chroma.2012.08.095] [Citation(s) in RCA: 46] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2012] [Revised: 08/28/2012] [Accepted: 08/29/2012] [Indexed: 01/13/2023]
Abstract
The integration of sample preparation methods into microfluidic devices provides automation necessary for achieving complete micro total analysis systems. We have developed a technique that combines on-chip sample enrichment with fluorescence labeling and purification. Polymer monoliths made from butyl methacrylate were fabricated in cyclic olefin copolymer microdevices and used for solid phase extraction. We studied the retention of fluorophores, amino acids and proteins on these columns. The retained samples were subsequently labeled with both Alexa Fluor 488 and Chromeo P503, and unreacted dye was rinsed off the column before sample elution. Additional purification was obtained from the differential retention of proteins and fluorescent labels. A linear relation between the eluted peak areas and concentrations of on-chip labeled heat shock protein 90 samples demonstrated the utility of this method for on-chip quantitation. Our fast and simple method of simultaneously concentrating and labeling samples on-chip is compatible with miniaturization and desirable for automated analysis.
Collapse
|
72
|
Chatterjee D, Mansfield DS, Anderson NG, Subedi S, Woolley AT. "Flow valve" microfluidic devices for simple, detectorless, and label-free analyte quantitation. Anal Chem 2012; 84:7057-63. [PMID: 22881075 DOI: 10.1021/ac301278s] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Simplified analysis systems that offer the performance of benchtop instruments but the convenience of portability are highly desirable. We have developed novel, miniature devices that feature visual inspection readout of a target's concentration from a ~1 μL volume of solution introduced into a microfluidic channel. Microchannels are constructed within an elastomeric material, and channel surfaces are coated with receptors to the target. When a solution is flowed into the channel, the target cross-links multiple receptors on the surface, resulting in constriction of the first few millimeters of the channel and stopping of flow. Quantitation is performed by measuring the distance traveled by the target solution in the channel before flow stops. A key advantage of our approach is that quantitation is accomplished by simple visual inspection of the channel, without the need for complex detection instrumentation. We have tested these devices using the model system of biotin as a receptor and streptavidin as the target. We have also characterized three factors that influence flow distance: solution viscosity, device thickness, and channel height. We found that solution capillary flow distance scales with the negative logarithm of target concentration and have detected streptavidin concentrations as low as 1 ng/mL. Finally, we have identified and evaluated a plausible mechanism wherein time-dependent channel constriction in the first few millimeters leads to concentration-dependent flow distances. Their simplicity coupled with performance makes these "flow valve" systems especially attractive for a host of analysis applications.
Collapse
|
73
|
Pearson AC, Liu J, Pound E, Uprety B, Woolley AT, Davis RC, Harb JN. DNA origami metallized site specifically to form electrically conductive nanowires. J Phys Chem B 2012; 116:10551-60. [PMID: 22578334 DOI: 10.1021/jp302316p] [Citation(s) in RCA: 68] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
DNA origami is a promising tool for use as a template in the design and fabrication of nanoscale structures. The ability to engineer selected staple strands on a DNA origami structure provides a high density of addressable locations across the structure. Here we report a method using site-specific attachment of gold nanoparticles to modified staple strands and subsequent metallization to fabricate conductive wires from DNA origami templates. We have modified DNA origami structures by lengthening each staple strand in select regions with a 10-base nucleotide sequence and have attached DNA-modified gold nanoparticles to the lengthened staple strands via complementary base-pairing. The high density of extended staple strands allowed the gold nanoparticles to pack tightly in the modified regions of the DNA origami, where the measured median gap size between neighboring particles was 4.1 nm. Gold metallization processes were optimized so that the attached gold nanoparticles grew until gaps between particles were filled and uniform continuous nanowires were formed. Finally, electron beam lithography was used to pattern electrodes in order to measure the electrical conductivity of metallized DNA origami, which showed an average resistance of 2.4 kΩ per metallized structure.
Collapse
|
74
|
Nge PN, Yang W, Pagaduan JV, Woolley AT. Ion-permeable membrane for on-chip preconcentration and separation of cancer marker proteins. Electrophoresis 2011; 32:1133-40. [PMID: 21544838 DOI: 10.1002/elps.201000698] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
Cancer marker proteins have been electrophoretically concentrated and then separated in a microfluidic device. On-chip preconcentration was achieved using an ion-permeable membrane, consisting of acrylamide, N,N'-methylene-bisacrylamide and 2-(acrylamido)-2-methylpropanesulfonate. This negatively charged membrane was photopolymerized in the microdevice near the injection intersection. Anionic proteins were excluded from the porous membrane based on both size and charge, which concentrated target components in the injection intersection prior to separation by microchip capillary electrophoresis (μ-CE). Bovine serum albumin was used in the initial characterization of the system and showed a 40-fold enrichment in the μ-CE peak with 4 min of preconcentration. Adjustment of buffer pH enabled baseline resolution of two cancer biomarkers, α-fetoprotein (AFP) and heat shock protein 90 (HSP90), while fine control over preconcentration time limited peak broadening. Our optimized preconcentration and μ-CE approach was applied to AFP and HSP90, where enrichment factors of >10-fold were achieved with just 1 min of preconcentration. Overall, the process was simple and rapid, providing a useful tool for improving detection in microscale systems.
Collapse
|
75
|
Rogers CI, Pagaduan JV, Nordin GP, Woolley AT. Single-monomer formulation of polymerized polyethylene glycol diacrylate as a nonadsorptive material for microfluidics. Anal Chem 2011; 83:6418-25. [PMID: 21728310 DOI: 10.1021/ac201539h] [Citation(s) in RCA: 50] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Nonspecific adsorption in microfluidic systems can deplete target molecules in solution and prevent analytes, especially those at low concentrations, from reaching the detector. Polydimethylsiloxane (PDMS) is a widely used material for microfluidics, but it is prone to nonspecific adsorption, necessitating complex chemical modification processes to address this issue. An alternative material to PDMS that does not require subsequent chemical modification is presented here. Poly(ethylene glycol) diacrylate (PEGDA) mixed with photoinitiator forms on exposure to ultraviolet (UV) radiation a polymer with inherent resistance to nonspecific adsorption. Optimization of the polymerized PEGDA (poly-PEGDA) formula imbues this material with some of the same properties, including optical clarity, water stability, and low background fluorescence, that make PDMS so popular. Poly-PEGDA demonstrates less nonspecific adsorption than PDMS over a range of concentrations of flowing fluorescently tagged bovine serum albumin solutions, and poly-PEGDA has greater resistance to permeation by small hydrophobic molecules than PDMS. Poly-PEGDA also exhibits long-term (hour scale) resistance to nonspecific adsorption compared to PDMS when exposed to a low (1 μg/mL) concentration of a model adsorptive protein. Electrophoretic separations of amino acids and proteins resulted in symmetrical peaks and theoretical plate counts as high as 4 × 10(5)/m. Poly-PEGDA, which displays resistance to nonspecific adsorption, could have broad use in small volume analysis and biomedical research.
Collapse
|