101
|
Ibarra-González I, Cruz-Bautista I, Bello-Chavolla OY, Vela-Amieva M, Pallares-Méndez R, Ruiz de Santiago Y Nevarez D, Salas-Tapia MF, Rosas-Flota X, González-Acevedo M, Palacios-Peñaloza A, Morales-Esponda M, Aguilar-Salinas CA, Del Bosque-Plata L. Optimization of kidney dysfunction prediction in diabetic kidney disease using targeted metabolomics. Acta Diabetol 2018; 55:1151-1161. [PMID: 30173364 DOI: 10.1007/s00592-018-1213-0] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/18/2018] [Accepted: 08/09/2018] [Indexed: 01/05/2023]
Abstract
AIMS Metabolomics have been used to evaluate the role of small molecules in human disease. However, the cost and complexity of the methodology and interpretation of findings have limited the transference of knowledge to clinical practice. Here, we apply a targeted metabolomics approach using samples blotted in filter paper to develop clinical-metabolomics models to detect kidney dysfunction in diabetic kidney disease (DKD). METHODS We included healthy controls and subjects with type 2 diabetes (T2D) with and without DKD and investigated the association between metabolite concentrations in blood and urine with eGFR and albuminuria. We also evaluated performance of clinical, biochemical and metabolomic models to improve kidney dysfunction prediction in DKD. RESULTS Using clinical-metabolomics models, we identified associations of decreased eGFR with body mass index (BMI), uric acid and C10:2 levels; albuminuria was associated to years of T2D duration, A1C, uric acid, creatinine, protein intake and serum C0, C10:2 and urinary C12:1 levels. DKD was associated with age, A1C, uric acid, BMI, serum C0, C10:2, C8:1 and urinary C12:1. Inclusion of metabolomics increased the predictive and informative capacity of models composed of clinical variables by decreasing Akaike's information criterion, and was replicated both in training and validation datasets. CONCLUSIONS Targeted metabolomics using blotted samples in filter paper is a simple, low-cost approach to identify outcomes associated with DKD; the inclusion of metabolomics improves predictive capacity of clinical models to identify kidney dysfunction and DKD-related outcomes.
Collapse
|
102
|
Bellevicine C, Troncone G. The cytopathologist's expanding role in the 2018 updated molecular testing guidelines for lung cancer. Cancer Cytopathol 2018; 126:753-755. [PMID: 30291815 DOI: 10.1002/cncy.22060] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
103
|
Wiesmann F, Ehret R, Naeth G, Däumer M, Fuhrmann J, Kaiser R, Noah C, Obermeier M, Schalasta G, Tiemann C, Wolf E, Knechten H, Braun P. Multicenter Evaluation of Two Next-Generation HIV-1 Quantitation Assays, Aptima Quant Dx and Cobas 6800, in Comparison to the RealTi me HIV-1 Reference Assay. J Clin Microbiol 2018; 56:e00292-18. [PMID: 30068537 PMCID: PMC6156314 DOI: 10.1128/jcm.00292-18] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2018] [Accepted: 06/23/2018] [Indexed: 01/09/2023] Open
Abstract
High accuracy and precision at the lower end of quantification are crucial requirements of a modern HIV viral load (VL) assay, since some clinically relevant thresholds are located at 50 and 200 copies/ml. In this study, we compared the performance of two new fully automated HIV-1 VL assays, Aptima HIV-1 Quant Dx and Cobas HIV-1 (Cobas 6800), with the established RealTime m2000 assay. Assay precision and accuracy were evaluated in a retrospective evaluation out of excess plasma material from four HIV-1+ individuals (subtypes B, C, CRF01_AE, and CRF02_AG). Native plasma samples were diluted to nominal concentrations at 50 and 200 copies/ml (according to the RealTime m2000 assay). All dilutions were tested in triplicate in five independent runs over 5 days and in three labs per system. Assay concordance was determined using 1,011 surplus clinical routine samples, as well as selected retrospective longitudinal samples from 7 patients on treatment. The three assays yielded highly concordant results for individual clinical samples (R2 > 0.98; average difference, ≤0.2 log copies/ml) and retrospective longitudinal samples from patients on treatment. The Aptima and RealTime assays showed similar high precision, meeting the 5σ criterion for the majority of samples across all labs and subtypes. The Cobas assay was less precise, missing the 5σ criterion for the majority of samples at low concentrations. In this analysis, results from the Cobas assay appeared less reliable near the clinically relevant cutoff and should be interpreted with more caution in this context. Due to high precision, full automation, and high concordance with the RealTime assay, the Aptima assay represents a good alternative in routine VL monitoring.
Collapse
|
104
|
Chiang S, Zhang W, Ouyang Z. Paper spray ionization mass spectrometry: recent advances and clinical applications. Expert Rev Proteomics 2018; 15:781-789. [PMID: 30223684 PMCID: PMC6320440 DOI: 10.1080/14789450.2018.1525295] [Citation(s) in RCA: 33] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
Abstract
INTRODUCTION Paper spray mass spectrometry has provided a rapid, quantitative ambient ionization method for xenobiotic and biomolecule analysis. As an alternative to traditional sample preparation and chromatography, paper spray demonstrates the sampling ionization of a wide range of molecules and significant sensitivity from complex biofluids. The amenability of paper spray with dried blood spots and other sampling types shows strong potential for rapid, point-of-care (POC) analysis without time-consuming separation procedures. Areas covered: This special report summarizes the current state and advances in paper spray mass spectrometry that relate to its applicability for clinical analysis. It also provides our perspectives on the future development of paper spray mass spectrometry and its potential roles in clinical settings. Expert commentary: Paper spray has provided the fundamental aspects of ambient ionization needed for implementation at the POC. With further clinical management and standardization, paper spray has the potential to replace traditional complex analysis procedure for rapid quantitative detection of illicit drugs, therapeutic drugs and metabolites. Surface and substrate modifications also offer significant improvement in desorption and ionization efficiencies, resulting in enhanced sensitivity. Comprehensive analysis of metabolites and lipids will further extend the implementation of paper spray ionization mass spectrometry into clinical applications.
Collapse
|
105
|
Louati S, Senhaji N, Chbani L, Bennis S. EWSR1 Rearrangement and CD99 Expression as Diagnostic Biomarkers for Ewing/PNET Sarcomas in a Moroccan Population. DISEASE MARKERS 2018; 2018:7971019. [PMID: 30319719 PMCID: PMC6167566 DOI: 10.1155/2018/7971019] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/15/2018] [Revised: 08/16/2018] [Accepted: 08/18/2018] [Indexed: 11/23/2022]
Abstract
Ewing sarcoma/primitive neuroectodermal tumor (Ewing/PNET sarcomas or EPS) are a group of round cell tumors. Malignant round cell tumors form a large and diverse group that includes rhabdomyosarcoma, synovial sarcoma, non-Hodgkin's lymphoma, neuroblastoma, hepatoblastoma, Wilm's tumor, desmoplastic small round cell tumor, and other morphologically similar entities. Differential diagnosis of Ewing sarcoma/primitive neuroectodermal tumor (Ewing/PNET sarcomas or EPS) is difficult. In addition to morphology and immunohistochemistry (IHC), differential diagnosis of these tumors is based on molecular analysis of the EWSR1 gene rearrangement using fluorescent in situ hybridization (FISH) technique. We investigated the diagnostic value of combined CD99 immunostaining and EWSR1 t(22q12) alteration using a dual-color, break-apart rearrangement probe in forty-one formalin-fixed paraffin-embedded (FFPE) tissue samples from pediatric and adult patients diagnosed with EPS. IHC was performed in all cases using the CD99 antibody and showed a positivity of 92.7% in the enrolled cases (38/41) followed by FISH analysis where 48.8% of the cases (20/41) were rearranged. Sensitivity and specificity for IHC assays were 88% and 58%, respectively. Notably, FISH had a sensitivity of 100% and a specificity of 87%. In addition, CD99 positivity was found to correlate with EWSR1 rearrangement (p < 0.05). This report shows that FISH has better sensitivity and specificity than IHC in the Moroccan population, and supports its combination with CD99 immunostaining as diagnostic biomarkers for this rare malignant entity."
Collapse
|
106
|
De Paschale M, Manco MT, Cianflone A, Belvisi L, Cagnin D, Cerulli T, Paganini A, Agrappi C, Mirri P, Clerici P. Evaluation of the vitros hiv combo 4th generation test for the identification of HIV infections. J Clin Virol 2018; 108:77-82. [PMID: 30266004 DOI: 10.1016/j.jcv.2018.09.010] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2018] [Revised: 09/11/2018] [Accepted: 09/14/2018] [Indexed: 11/19/2022]
Abstract
BACKGROUND Simultaneous detection of HIV 1 and 2 antibodies and HIV-1 p-24 antigen in the 4th generation tests is particularly effective for the identification of early acute HIV infections while maintaining accurate detection of long-established infections. OBJECTIVES The aim of this study was to evaluate the new 4th generation VITROS HIV Combo test from Ortho-Clinical Diagnostics by comparing its results with those obtained using a 3rd generation HIV 1/2 antibody test (VITROS Anti HIV 1 + 2 from Ortho-Clinical Diagnostics) and a 4th generation test (LIAISON XL HIV Ab/Ag, DiaSorin) currently used in the Microbiology Unit of Legnano Hospital. STUDY DESIGN One thousand and three samples of the normal daily routine (Group 1) were analyzed simultaneously with the three systems. The concordant and discordant sample results were further tested using Western blot and HIV-RNA assay (Roche). One hundred samples (Group 2) of known HIV positive subjects (63 of subtype B, 37 subtype non-B, and 51 with positive viraemia) and 50 samples (Group 3) with indeterminate Western blot were also examined using the three systems. From Group 3, 24 samples were collected from patients diagnosed with acute infection. RESULTS The overall agreement between the three systems was 99.4% (99.5% in group 1, 100% in group 2 and 96.6% in group 3) with a coefficient Fleiss Kappa of 0.9814. Notably, the VITROS HIV Combo test was positive in all known HIV positive samples of group 2 without any statistically significant difference in the values of the sample/cut off ratios between the B and non-B subtypes and between the positive and negative viraemia samples in established infections. The VITROS HIV Combo test was also positive in all samples of patients with acute infection in group 3. CONCLUSIONS The VITROS HIV Combo test has shown comparable performance to the other two assays in use of 3rd and 4th generation tests and is able to correctly identify both acute and established HIV infections independently of viraemia and HIV subtype.
Collapse
|
107
|
Donoso Mantke O, McCulloch E, Wallace PS, Yue C, Baylis SA, Niedrig M. External Quality Assessment (EQA) for Molecular Diagnostics of Zika Virus: Experiences from an International EQA Programme, 2016⁻2018. Viruses 2018; 10:v10090491. [PMID: 30216988 PMCID: PMC6163558 DOI: 10.3390/v10090491] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2018] [Revised: 09/10/2018] [Accepted: 09/12/2018] [Indexed: 11/16/2022] Open
Abstract
Quality Control for Molecular Diagnostics (QCMD), an international provider for External Quality Assessment (EQA) programmes, has introduced a programme for molecular diagnostics of Zika virus (ZIKV) in 2016, which has been continuously offered to interested laboratories since that time. The EQA schemes provided from 2016 to 2018 revealed that 86.7% (92/106), 82.4% (89/108), and 88.2% (90/102) of the participating laboratories reported correct results for all samples, respectively in 2016, 2017, and 2018. The review of results indicated a need for improvement concerning analytical sensitivity and specificity of the test methods. Comparison with the outcomes of other EQA initiatives briefly summarized here show that continuous quality assurance is important to improve laboratory performance and to increase preparedness with reliable diagnostic assays for effective patient management, infection and outbreak control.
Collapse
|
108
|
Gao Y, Zhang Z, Deng J, Mansjö M, Ning Z, Li Y, Li X, Hu Y, Hoffner S, Xu B. Multi-center evaluation of GenoType MTBDRsl line probe assay for rapid detection of pre-XDR and XDR Mycobacterium tuberculosis in China. J Infect 2018; 77:328-334. [PMID: 29969597 DOI: 10.1016/j.jinf.2018.06.014] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2018] [Revised: 06/07/2018] [Accepted: 06/18/2018] [Indexed: 11/18/2022]
Abstract
OBJECTIVES The implementation of rapid and reliable drug susceptibilities diagnosis is fundamental for effective treatment of multidrug-resistant tuberculosis(MDR-TB). The present study aimed to assess the diagnostic performance of the 2nd-version GenoType MTBDRsl kit as well as the impact of its implementation on the turnaround time in a multi-center Chinese study. METHODS Totally 353 MDR-TB patient specimens were consecutively tested. The 2nd-version GenoType MTBDRsl assay, drug susceptibility testing with the MGIT 960 system, and sequencing were performed and compared. RESULTS MTBDRsl testing identified the major genotypes associated with fluoroquinolones resistance, predominated by gyrA MUT3B (Asp94Asn and Asp94Tyr, 26.5%) and MUT3C (Asp94Gly, 19.5%). The genotypes associated with resistance to 2nd-line injectable drugs(SLIDs) were rrsMUT1(A1401G, 64.9%) and absence of WT1(C1402T, 10.5%). The sensitivities for detection of resistance to fluoroquinolones, SLIDs, and their combination (extensively drug resistance, XDR) were 80.5%, 80.7% and 73.5% and specificities were 100.0%, 99.3% and 99.1%, respectively. Implementation of this test significantly reduced the turnaround time between sample collection and result reporting from 45 to 3 days, a reduction by 93.3% (p, 0.001). CONCLUSION With a favorable diagnostic performance and short turnaround time, the 2nd-version GenoType MTBDRsl assay proves its value for early diagnosis of resistance to 2nd-line drugs as well as of XDR-TB in China.
Collapse
|
109
|
Prakash AK, Datta B, Tripathy JP, Kumar N, Chatterjee P, Jaiswal A. The clinical utility of cycle of threshold value of GeneXpert MTB/RIF (CBNAAT) and its diagnostic accuracy in pulmonary and extra-pulmonary samples at a tertiary care center in India. Indian J Tuberc 2018; 65:296-302. [PMID: 30522616 DOI: 10.1016/j.ijtb.2018.05.021] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2018] [Revised: 05/23/2018] [Accepted: 05/24/2018] [Indexed: 12/19/2022]
Abstract
BACKGROUND There are knowledge gaps in the in-depth analysis of the most promising and robust diagnostic tool, GeneXpert MTB/RIF (CBNAAT). The cycle of threshold (CT) value of the CBNAAT test and its clinical implications has not been explored much. AIMS AND OBJECTIVES The study aimed at (a) estimating the diagnostic accuracy and incremental yield of Xpert MTB/RIF in various specimens (b) establishing the association between CT value category (high, medium, low, very low) and culture time-to-positivity (TTP). METHODS A total of 1000 samples, both pulmonary and extra-pulmonary were collected from presumptive TB cases in a large tertiary care hospital. Sensitivity and specificity of CBNAAT was calculated with culture as the gold standard. The association of CT value with culture TTP was also studied. RESULTS The overall sensitivity of CBNAAT was 88.5%, with bronchial washing specimen being the most sensitive (92.3%) and pleural fluid being the least (66.7%). In smear negative individuals, the sensitivity of CBNAAT was 80.9%. The additional yield of CBNAAT over smear microscopy was 10.9%. It was observed that as we move from high to very low CT category, culture positivity decreases significantly (p<0.001), whereas time taken for culture growth increases (p<0.001). CONCLUSION CBNAAT is a robust test for accurate diagnosis of tuberculosis both pulmonary and extra-pulmonary, smear negative as well, especially in resource-limited settings. The correlation between CT value and culture TTP has potential in predicting bacillary load, though further studies are required.
Collapse
|
110
|
Yuan X, Bai C, Cui Q, Zhang H, Yuan J, Niu K, Feng Y, Jin X, Li P, Liu H. Rapid detection of Mycoplasma pneumoniae by loop-mediated isothermal amplification assay. Medicine (Baltimore) 2018; 97:e10806. [PMID: 29923972 PMCID: PMC6023700 DOI: 10.1097/md.0000000000010806] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/27/2022] Open
Abstract
To improve the diagnosis and treatment of Mycoplasma pneumoniae (Mp) infection and reduce the misuse of antibiotics, we sought to establish a loop-mediated isothermal amplification (LAMP) assay for rapid detection of Mp.Six primers specific for the Mp P1 gene were designed, and the LAMP method was used to rapidly detect Mp. The sensitivity of the LAMP method was determined by serial dilution of the standard Mp strain FH (standard strains of Mycoplasma pneumoniae). Specificity was assessed with 17 common pathogenic microorganisms in the respiratory tract. Patient samples were collected from the Department of Respiratory and Critical Care Medicine at the 307th Hospital of Chinese People's Liberation Army from March 2016 to May 2017, examined prospectively, and compared with diagnosis by quantitative real-time polymerase chain reaction (qRT-PCR).The LAMP assay for Mp detection can be completed within 60 minutes. The minimum detection limit was 39 pg/μL, and no cross-reaction was observed with 17 common respiratory tract pathogens. Of the 125 clinical specimens tested, 43 cases were positive by LAMP assay, and 40 cases were positive by qRT-PCR (P = .162). All 43 samples determined as positive by LAMP test were confirmed to be Mp by Mp P1 protein sequencing.The LAMP assay is suitable for rapid detection of Mp. It has high sensitivity and specificity, and the detection results are not inferior to those of qRT-PCR.
Collapse
|
111
|
Fischer C, Pedroso C, Mendrone A, Bispo de Filippis AM, Vallinoto ACR, Ribeiro BM, Durigon EL, Marques ETA, Campos GS, Viana IFT, Levi JE, Scarpelli LC, Nogueira ML, Bastos MDS, Souza NCS, Khouri R, Lira S, Komninakis SV, Baronti C, Charrel RN, Kümmerer BM, Drosten C, Brites C, de Lamballerie X, Niedrig M, Netto EM, Drexler JF. External Quality Assessment for Zika Virus Molecular Diagnostic Testing, Brazil. Emerg Infect Dis 2018; 24. [PMID: 29470164 PMCID: PMC5938781 DOI: 10.3201/eid2405.171747] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
Abstract
We conducted an external quality assessment of Zika virus molecular diagnostic tests in Brazil using a new Zika virus standard. Of 15 laboratories, 73% showed limited sensitivity and specificity. Viral load estimates varied significantly. Continuous quality assurance is required for adequate estimates of Zika virus–associated disease and determination of patient care.
Collapse
|
112
|
Sinha M, Jupe J, Mack H, Coleman TP, Lawrence SM, Fraley SI. Emerging Technologies for Molecular Diagnosis of Sepsis. Clin Microbiol Rev 2018; 31:e00089-17. [PMID: 29490932 PMCID: PMC5967692 DOI: 10.1128/cmr.00089-17] [Citation(s) in RCA: 177] [Impact Index Per Article: 29.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022] Open
Abstract
Rapid and accurate profiling of infection-causing pathogens remains a significant challenge in modern health care. Despite advances in molecular diagnostic techniques, blood culture analysis remains the gold standard for diagnosing sepsis. However, this method is too slow and cumbersome to significantly influence the initial management of patients. The swift initiation of precise and targeted antibiotic therapies depends on the ability of a sepsis diagnostic test to capture clinically relevant organisms along with antimicrobial resistance within 1 to 3 h. The administration of appropriate, narrow-spectrum antibiotics demands that such a test be extremely sensitive with a high negative predictive value. In addition, it should utilize small sample volumes and detect polymicrobial infections and contaminants. All of this must be accomplished with a platform that is easily integrated into the clinical workflow. In this review, we outline the limitations of routine blood culture testing and discuss how emerging sepsis technologies are converging on the characteristics of the ideal sepsis diagnostic test. We include seven molecular technologies that have been validated on clinical blood specimens or mock samples using human blood. In addition, we discuss advances in machine learning technologies that use electronic medical record data to provide contextual evaluation support for clinical decision-making.
Collapse
|
113
|
Pena LDM, Jiang YH, Schoch K, Spillmann RC, Walley N, Stong N, Horn SR, Sullivan JA, McConkie-Rosell A, Kansagra S, Smith EC, El-Dairi M, Bellet J, Ann Keels M, Jasien J, Kranz PG, Noel R, Nagaraj SK, Lark RK, Wechsler DSG, del Gaudio D, Leung ML, Hendon LG, Parker CC, Jones KL, Goldstein DB, Shashi V. Looking beyond the exome: a phenotype-first approach to molecular diagnostic resolution in rare and undiagnosed diseases. Genet Med 2018; 20:464-469. [PMID: 28914269 PMCID: PMC5851806 DOI: 10.1038/gim.2017.128] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2017] [Accepted: 06/16/2017] [Indexed: 12/01/2022] Open
Abstract
PurposeTo describe examples of missed pathogenic variants on whole-exome sequencing (WES) and the importance of deep phenotyping for further diagnostic testing.MethodsGuided by phenotypic information, three children with negative WES underwent targeted single-gene testing.ResultsIndividual 1 had a clinical diagnosis consistent with infantile systemic hyalinosis, although WES and a next-generation sequencing (NGS)-based ANTXR2 test were negative. Sanger sequencing of ANTXR2 revealed a homozygous single base pair insertion, previously missed by the WES variant caller software. Individual 2 had neurodevelopmental regression and cerebellar atrophy, with no diagnosis on WES. New clinical findings prompted Sanger sequencing and copy number testing of PLA2G6. A novel homozygous deletion of the noncoding exon 1 (not included in the WES capture kit) was detected, with extension into the promoter, confirming the clinical suspicion of infantile neuroaxonal dystrophy. Individual 3 had progressive ataxia, spasticity, and magnetic resonance image changes of vanishing white matter leukoencephalopathy. An NGS leukodystrophy gene panel and WES showed a heterozygous pathogenic variant in EIF2B5; no deletions/duplications were detected. Sanger sequencing of EIF2B5 showed a frameshift indel, probably missed owing to failure of alignment.ConclusionThese cases illustrate potential pitfalls of WES/NGS testing and the importance of phenotype-guided molecular testing in yielding diagnoses.
Collapse
|
114
|
Marks M, Fookes M, Wagner J, Butcher R, Ghinai R, Sokana O, Sarkodie YA, Lukehart SA, Solomon AW, Mabey DCW, Thomson N. Diagnostics for Yaws Eradication: Insights From Direct Next-Generation Sequencing of Cutaneous Strains of Treponema pallidum. Clin Infect Dis 2018; 66:818-824. [PMID: 29045605 PMCID: PMC5848336 DOI: 10.1093/cid/cix892] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2017] [Accepted: 10/13/2017] [Indexed: 11/23/2022] Open
Abstract
Background Yaws-like chronic ulcers can be caused by Treponema pallidum subspecies pertenue, Haemophilus ducreyi, or other, still-undefined bacteria. To permit accurate evaluation of yaws elimination efforts, programmatic use of molecular diagnostics is required. The accuracy and sensitivity of current tools remain unclear because our understanding of T. pallidum diversity is limited by the low number of sequenced genomes. Methods We tested samples from patients with suspected yaws collected in the Solomon Islands and Ghana. All samples were from patients whose lesions had previously tested negative using the Centers for Disease Control and Prevention (CDC) diagnostic assay in widespread use. However, some of these patients had positive serological assays for yaws on blood. We used direct whole-genome sequencing to identify T. pallidum subsp pertenue strains missed by the current assay. Results From 45 Solomon Islands and 27 Ghanaian samples, 11 were positive for T. pallidum DNA using the species-wide quantitative polymerase chain reaction (PCR) assay, from which we obtained 6 previously undetected T. pallidum subsp pertenue whole-genome sequences. These show that Solomon Islands sequences represent distinct T. pallidum subsp pertenue clades. These isolates were invisible to the CDC diagnostic PCR assay, due to sequence variation in the primer binding site. Conclusions Our data double the number of published T. pallidum subsp pertenue genomes. We show that Solomon Islands strains are undetectable by the PCR used in many studies and by health ministries. This assay is therefore not adequate for the eradication program. Next-generation genome sequence data are essential for these efforts.
Collapse
|
115
|
Rodrigues CMC, Groves H. Community-Acquired Pneumonia in Children: the Challenges of Microbiological Diagnosis. J Clin Microbiol 2018; 56:e01318-17. [PMID: 29237789 PMCID: PMC5824044 DOI: 10.1128/jcm.01318-17] [Citation(s) in RCA: 44] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
Community-acquired pneumonia (CAP) is the leading cause of mortality in children under 5 years of age globally. To improve the management of CAP, we must distinguish CAP from other common pediatric conditions and develop better diagnostic methods to detect the causative organism, so as to best direct appropriate resources in both industrialized and developing countries. Here, we review the diagnostic modalities available for identifying viruses and bacteria in the upper and lower respiratory tract of children, with a discussion of their utility and limitations in diagnosing CAP in children.
Collapse
|
116
|
Derendinger B, de Vos M, Nathavitharana RR, Dolby T, Simpson JA, van Helden PD, Warren RM, Theron G. Widespread use of incorrect PCR ramp rate negatively impacts multidrug-resistant tuberculosis diagnosis (MTBDRplus). Sci Rep 2018; 8:3206. [PMID: 29453405 PMCID: PMC5816666 DOI: 10.1038/s41598-018-21458-y] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2017] [Accepted: 02/06/2018] [Indexed: 11/09/2022] Open
Abstract
The scale-up of rapid drug resistance testing for TB is a global priority. MTBDRplus is a WHO-endorsed multidrug-resistant (MDR)-TB PCR assay with suboptimal sensitivities and high indeterminate rates on smear-negative specimens. We hypothesised that widespread use of incorrect thermocycler ramp rate (speed of temperature change between cycles) impacts performance. A global sample of 72 laboratories was surveyed. We tested 107 sputa from Xpert MTB/RIF-positive patients and, separately, dilution series of bacilli, both at the manufacturer-recommended ramp rate (2.2 °C/s) and the most frequently reported incorrect ramp rate (4.0 °C/s). Mycobacterium tuberculosis-complex DNA (TUB-band)-detection, indeterminate results, accuracy, and inter-reader variability (dilution series only) were compared. 32 respondents did a median (IQR) of 41 (20-150) assays monthly. 78% used an incorrect ramp rate. On smear-negative sputa, 2.2 °C/s vs. 4.0 °C/s improved TUB-band positivity (42/55 vs. 32/55; p = 0.042) and indeterminate rates (1/42 vs. 5/32; p = 0.039). The actionable results (not TUB-negative or indeterminate; 41/55 vs. 28/55) hence improved by 21% (95% CI: 9-35%). Widespread use of incorrect ramp rate contributes to suboptimal MTBDRplus performance on smear-negative specimens and hence limits clinical utility. The number of diagnoses (and thus the number of smear-negative patients in whom DST is possible) will improve substantially after ramp rate correction.
Collapse
|
117
|
O' Leary JK, Blake L, Corcoran D, Sleator RD, Lucey B. Trials and Tribulations of Enteric Parasitology in the Molecular Era. J Med Microbiol 2018; 67:145-147. [PMID: 29265996 DOI: 10.1099/jmm.0.000670] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
|
118
|
Gleichenhagen J, Arndt C, Casjens S, Meinig C, Gerullis H, Raiko I, Brüning T, Ecke T, Johnen G. Evaluation of a New Survivin ELISA and UBC ® Rapid for the Detection of Bladder Cancer in Urine. Int J Mol Sci 2018; 19:ijms19010226. [PMID: 29324722 PMCID: PMC5796175 DOI: 10.3390/ijms19010226] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2017] [Revised: 12/20/2017] [Accepted: 01/08/2018] [Indexed: 12/21/2022] Open
Abstract
Urine-based biomarkers for non-invasive diagnosis of bladder cancer are urgently needed. No single marker with sufficient sensitivity and specificity has been described so far. Thus, a combination of markers appears to be a promising approach. The aim of this case-control study was to evaluate the performance of an in-house developed enzyme-linked immunosorbent assay (ELISA) for survivin, the UBC®Rapid test, and the combination of both assays. A total of 290 patients were recruited. Due to prior bladder cancer, 46 patients were excluded. Urine samples were available from 111 patients with bladder cancer and 133 clinical controls without urologic diseases. Antibodies generated from recombinant survivin were utilized to develop a sandwich ELISA. The ELISA and the UBC®Rapid test were applied to all urine samples. Receiver operating characteristic (ROC) analysis was used to evaluate marker performance. The survivin ELISA exhibited a sensitivity of 35% with a specificity of 98%. The UBC®Rapid test showed a sensitivity of 56% and a specificity of 96%. Combination of both assays increased the sensitivity to 66% with a specificity of 95%. For high-grade tumors, the combination showed a sensitivity of 82% and a specificity of 95%. The new survivin ELISA and the UBC®Rapid test are both able to detect bladder cancer, especially high-grade tumors. However, the performance of each individual marker is moderate and efforts to improve the survivin assay should be pursued. A combination of both assays confirmed the benefit of using marker panels. The results need further testing in a prospective study and with a high-risk population.
Collapse
|
119
|
Madhavan S, Ritter D, Micheel C, Rao S, Roy A, Sonkin D, Mccoy M, Griffith M, Griffith OL, Mcgarvey P, Kulkarni S. ClinGen Cancer Somatic Working Group - standardizing and democratizing access to cancer molecular diagnostic data to drive translational research. PACIFIC SYMPOSIUM ON BIOCOMPUTING. PACIFIC SYMPOSIUM ON BIOCOMPUTING 2018; 23:247-258. [PMID: 29218886 PMCID: PMC5728662] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
A growing number of academic and community clinics are conducting genomic testing to inform treatment decisions for cancer patients (1). In the last 3-5 years, there has been a rapid increase in clinical use of next generation sequencing (NGS) based cancer molecular diagnostic (MolDx) testing (2). The increasing availability and decreasing cost of tumor genomic profiling means that physicians can now make treatment decisions armed with patient-specific genetic information. Accumulating research in the cancer biology field indicates that there is significant potential to improve cancer patient outcomes by effectively leveraging this rich source of genomic data in treatment planning (3). To achieve truly personalized medicine in oncology, it is critical to catalog cancer sequence variants from MolDx testing for their clinical relevance along with treatment information and patient outcomes, and to do so in a way that supports large-scale data aggregation and new hypothesis generation. One critical challenge to encoding variant data is adopting a standard of annotation of those variants that are clinically actionable. Through the NIH-funded Clinical Genome Resource (ClinGen) (4), in collaboration with NLM's ClinVar database and >50 academic and industry based cancer research organizations, we developed the Minimal Variant Level Data (MVLD) framework to standardize reporting and interpretation of drug associated alterations (5). We are currently involved in collaborative efforts to align the MVLD framework with parallel, complementary sequence variants interpretation clinical guidelines from the Association of Molecular Pathologists (AMP) for clinical labs (6). In order to truly democratize access to MolDx data for care and research needs, these standards must be harmonized to support sharing of clinical cancer variants. Here we describe the processes and methods developed within the ClinGen's Somatic WG in collaboration with over 60 cancer care and research organizations as well as CLIA-certified, CAP-accredited clinical testing labs to develop standards for cancer variant interpretation and sharing.
Collapse
|
120
|
Coelho H, Jones-Hughes T, Snowsill T, Briscoe S, Huxley N, Frayling IM, Hyde C. A systematic review of test accuracy studies evaluating molecular micro-satellite instability testing for the detection of individuals with lynch syndrome. BMC Cancer 2017; 17:836. [PMID: 29221446 PMCID: PMC5723028 DOI: 10.1186/s12885-017-3820-5] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2017] [Accepted: 11/22/2017] [Indexed: 11/24/2022] Open
Abstract
BACKGROUND A systematic review was conducted to assess the diagnostic test accuracy of polymerase chain reaction (PCR)-based microsatellite instability (MSI) testing for identifying Lynch syndrome in patients with colorectal cancer (CRC). Unlike previous reviews, this was based on assessing MSI testing against best practice for the reference standard, and included CRC populations that were unselected, age-limited or high-risk for Lynch syndrome. METHODS Single- and two-gate diagnostic test accuracy studies, or similar, were identified, assessed for inclusion, data extracted and quality appraised by two reviewers according to a pre-specified protocol. Sensitivity of MSI testing was estimated for all included studies. Specificity, likelihood ratios and predictive values were estimated for studies that were not based on high-risk samples. Narrative synthesis was conducted. RESULTS Nine study samples were included. When MSI-Low results were considered to be negative, sensitivity estimates ranged from 67% (95% CI 47, 83) to 100% (95% CI 94, 100). Three studies contributed to estimates of both sensitivity and specificity, with specificity ranging from 61% (95% CI 57, 65), to 93% (95% CI 89, 95). Good sensitivity was achieved at the expense of specificity. When MSI-L was considered to be positive (effectively lowering the threshold for a positive index test result) sensitivity increased and specificity decreased. Between-study heterogeneity in both the MSI and reference standard testing, combined with the low number of studies contributing to both sensitivity and specificity estimates, precluded pooling by meta-analysis. CONCLUSIONS MSI testing is an effective screening test for Lynch syndrome. However, there is significant uncertainty surrounding what balance of sensitivity and specificity will be achieved in clinical practice and how this relates to specific characteristics of the test (such as the panel of markers used or the thresholds used to denote a positive test).
Collapse
|
121
|
Mena M, Lloveras B, Tous S, Bogers J, Maffini F, Gangane N, Kumar RV, Somanathan T, Lucas E, Anantharaman D, Gheit T, Castellsagué X, Pawlita M, de Sanjosé S, Alemany L, Tommasino M. Development and validation of a protocol for optimizing the use of paraffin blocks in molecular epidemiological studies: The example from the HPV-AHEAD study. PLoS One 2017; 12:e0184520. [PMID: 29036167 PMCID: PMC5642890 DOI: 10.1371/journal.pone.0184520] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2017] [Accepted: 08/27/2017] [Indexed: 12/11/2022] Open
Abstract
Worldwide use of formalin-fixed paraffin-embedded blocks (FFPE) is extensive in diagnosis and research. Yet, there is a lack of optimized/standardized protocols to process the blocks and verify the quality and presence of the targeted tissue. In the context of an international study on head and neck cancer (HNC)-HPV-AHEAD, a standardized protocol for optimizing the use of FFPEs in molecular epidemiology was developed and validated. First, a protocol for sectioning the FFPE was developed to prevent cross-contamination and distributed between participating centers. Before processing blocks, all sectioning centers underwent a quality control to guarantee a satisfactory training process. The first and last sections of the FFPEs were used for histopathological assessment. A consensus histopathology evaluation form was developed by an international panel of pathologists and evaluated for four indicators in a pilot analysis in order to validate it: 1) presence/type of tumor tissue, 2) identification of other tissue components that could affect the molecular diagnosis and 3) quality of the tissue. No HPV DNA was found in sections from empty FFPE generated in any histology laboratories of HPV-AHEAD consortium and all centers passed quality assurance for processing after quality control. The pilot analysis to validate the histopathology form included 355 HNC cases. The form was filled by six pathologists and each case was randomly assigned to two of them. Most samples (86%) were considered satisfactory. Presence of >50% of invasive carcinoma was observed in all sections of 66% of cases. Substantial necrosis (>50%) was present in <2% of samples. The concordance for the indicators targeted to validate the histopathology form was very high (kappa > 0.85) between first and last sections and fair to high between pathologists (kappa/pabak 0.21-0.72). The protocol allowed to correctly process without signs of contamination all FFPE of the study. The histopathology evaluation of the cases assured the presence of the targeted tissue, identified the presence of other tissues that could disturb the molecular diagnosis and allowed the assessment of tissue quality.
Collapse
|
122
|
Executive summary of the 9th meeting of the WHO working group RT-PCR for the detection and subtyping of influenza viruses. RELEVE EPIDEMIOLOGIQUE HEBDOMADAIRE 2017; 92:609-610. [PMID: 29028164] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
|
123
|
Rusinek D, Chmielik E, Krajewska J, Jarzab M, Oczko-Wojciechowska M, Czarniecka A, Jarzab B. Current Advances in Thyroid Cancer Management. Are We Ready for the Epidemic Rise of Diagnoses? Int J Mol Sci 2017; 18:E1817. [PMID: 28829399 PMCID: PMC5578203 DOI: 10.3390/ijms18081817] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2017] [Revised: 08/16/2017] [Accepted: 08/16/2017] [Indexed: 02/07/2023] Open
Abstract
A rising incidence of thyroid cancers (TCs) mainly small tumors, observed during recent years, lead to many controversies regarding treatment strategies. TCs represent a distinct molecular background and clinical outcome. Although in most cases TCs are characterized by a good prognosis, there are some aggressive forms, which do not respond to standard treatment. There are still some questions, which have to be resolved to avoid dangerous simplifications in the clinical management. In this article, we focused on the current advantages in preoperative molecular diagnostic tests and histopathological examination including noninvasive follicular thyroid neoplasm with papillary-like nuclear features (NIFTP). We discussed the controversies regarding the extent of thyroid surgery and adjuvant radioiodine therapy, as well as new treatment modalities for radioiodine-refractory differentiated thyroid cancer (RR-DTC). Considering medullary thyroid cancer (MTC), we analyzed a clinical management based on histopathology and RET (ret proto-oncogene) mutation genotype, disease follow-up with a special attention to serum calcitonin doubling time as an important prognostic marker, and targeted therapy applied in advanced MTC. In addition, we provided some data regarding anaplastic thyroid cancer (ATC), a highly lethal neoplasm, which lead to death in nearly 100% of patients due to the lack of effective treatment options.
Collapse
|
124
|
Pipelers P, Clement L, Vynck M, Hellemans J, Vandesompele J, Thas O. A unified censored normal regression model for qPCR differential gene expression analysis. PLoS One 2017; 12:e0182832. [PMID: 28817597 PMCID: PMC5560691 DOI: 10.1371/journal.pone.0182832] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2017] [Accepted: 07/25/2017] [Indexed: 11/18/2022] Open
Abstract
Reverse transcription quantitative polymerase chain reaction (RT-qPCR) is considered as the gold standard for accurate, sensitive, and fast measurement of gene expression. Prior to downstream statistical analysis, RT-qPCR fluorescence amplification curves are summarized into one single value, the quantification cycle (Cq). When RT-qPCR does not reach the limit of detection, the Cq is labeled as "undetermined". Current state of the art qPCR data analysis pipelines acknowledge the importance of normalization for removing non-biological sample to sample variation in the Cq values. However, their strategies for handling undetermined Cq values are very ad hoc. We show that popular methods for handling undetermined values can have a severe impact on the downstream differential expression analysis. They introduce a considerable bias and suffer from a lower precision. We propose a novel method that unites preprocessing and differential expression analysis in a single statistical model that provides a rigorous way for handling undetermined Cq values. We compare our method with existing approaches in a simulation study and on published microRNA and mRNA gene expression datasets. We show that our method outperforms traditional RT-qPCR differential expression analysis pipelines in the presence of undetermined values, both in terms of accuracy and precision.
Collapse
|
125
|
Schenk D, Song G, Ke Y, Wang Z. Amplification of overlapping DNA amplicons in a single-tube multiplex PCR for targeted next-generation sequencing of BRCA1 and BRCA2. PLoS One 2017; 12:e0181062. [PMID: 28704513 PMCID: PMC5507532 DOI: 10.1371/journal.pone.0181062] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2016] [Accepted: 06/26/2017] [Indexed: 11/18/2022] Open
Abstract
Current PCR-based target enrichment methods for next generation sequencing (NGS) of overlapping amplicons often requires separate PCR reactions and subsequent pooling of amplicons from the different reactions. The study presents a novel method, deemed stem-loop inhibition mediated amplification (SLIMamp), for amplifying overlapping or tiled amplicons in a single multiplex PCR reaction. During a SLIMamp PCR reaction, a stem loop structure formed by the overlapping amplicon suppresses additional amplification of itself by preventing the annealing of the primers. Using the SLIMamp strategy, we designed a next-generation sequencing (NGS) assay to enrich the exon regions of BRCA1 and BRCA2 for sequencing on an Illumina MiSeq system. We used 35 cell line DNAs and 6 patient blood DNAs in the study to evaluate the assay performance. For each sample, all targeted regions were successfully amplified and sequenced with excellent coverage uniformity and specificity. >99% of the total sequencing reads were mapped to the human reference genome (hg19) and >99% of the mapped reads were on the targeted exons. >98% of bases were covered at >0.20x of the mean coverage and >99% are covered at >0.15x of the mean depth. Among 34 independently sequenced samples, all variants were reliably detected with no false positives or false negatives. SLIMamp provides a robust method for single-tube multiplex PCR amplification of numerous, overlapping amplicons that tile for targeted next-generation sequencing.
Collapse
|
126
|
Lindenmeyer MT, Kretzler M. Renal biopsy-driven molecular target identification in glomerular disease. Pflugers Arch 2017; 469:1021-1028. [PMID: 28664406 DOI: 10.1007/s00424-017-2006-y] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2017] [Accepted: 05/25/2017] [Indexed: 12/12/2022]
Abstract
Chronic kidney disease has severe impacts on the patient and represents a major burden to the health care systems worldwide. Despite an increased knowledge of pathophysiological processes involved in kidney diseases, the progress in defining novel treatment strategies has been limited. One reason is the descriptive disease categorization used in nephrology based on clinical findings or histopathological categories irrespective of potential different molecular disease mechanisms. To accelerate progress toward a targeted treatment, a definition of human disease extending from phenotypic disease classification to mechanism-based disease definitions is needed. In recent years, we have witnessed a major transition in biomedical research from a single gene research to an information rich and collaborative science. Tissue-based analysis in renal disease allows to link structure to molecular function. In our review, we introduce the concept of precision medicine in nephrology, describe several large cohort studies established for molecular analysis of kidney diseases, and highlight examples of renal biopsy-driven target identification by integrative systems biology approaches. Furthermore, we give an outlook on how the new disease definitions can be used for patient stratification in clinical trial design. Finally, we introduce the concept of an informational commons of renal precision medicine for joint analyses of large-scale data sets in renal failure.
Collapse
|
127
|
Mendez-Pena JE, Sadow PM, Nose V, Hoang MP. RNA chromogenic in situ hybridization assay with clinical automated platform is a sensitive method in detecting high-risk human papillomavirus in squamous cell carcinoma. Hum Pathol 2017; 63:184-189. [PMID: 28302536 DOI: 10.1016/j.humpath.2017.02.021] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/28/2016] [Revised: 01/31/2017] [Accepted: 02/23/2017] [Indexed: 01/30/2023]
Abstract
Detection of active human papillomavirus (HPV) is clinically important because its presence has been shown to correlate with favorable clinical outcomes and better response to treatment in oropharyngeal squamous cell carcinomas. Using a clinical automated platform, we compared the performance of commercially available HPV DNA and RNA in situ hybridization (ISH) probes in archival tissues of 57 squamous cell carcinomas. Importantly, a clinical automated platform gives (1) consistent and reproducible results for HPV ISH and (2) better standardization across clinical laboratories. Compared with polymerase chain reaction results, RNA ISH exhibited 93% concordance versus 81% of DNA ISH. RNA ISH was more sensitive than DNA ISH (100% versus 88%) and more specific (87% versus 74%). When only accounting for 2+-3+ positivity, sensitivity was 92% for RNA ISH versus 73% for DNA ISH, highlighting the ease of interpretation. p16 exhibited 96% sensitivity, whereas specificity was only 55%. In 3 cases, both RNA and DNA ISH were positive, whereas polymerase chain reaction results were negative, suggesting that ISH methods might be a more sensitive method. Performing on a clinical automated platform, RNA ISH is sensitive in determining high-risk HPV status in formalin-fixed, paraffin-embedded tissues and has the potential of being a standalone clinical test.
Collapse
|
128
|
Sharma K, Meena RK, Aggarwal A, Chhabra R. Multiplex PCR as a novel method in the diagnosis of spinal tuberculosis-a pilot study. Acta Neurochir (Wien) 2017; 159:503-507. [PMID: 28110400 DOI: 10.1007/s00701-016-3065-0] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2016] [Accepted: 12/21/2016] [Indexed: 11/28/2022]
Abstract
BACKGROUND Establishment of a reliable and rapid diagnosis is of paramount importance in spinal tuberculosis. The available gadgetry of investigations, such as AFB smear, culture of Mycobacterium tuberculosis, and Uniplex PCR, suffers from a lack of adequate sensitivity and/or a lack of rapidity. Therefore, many times a diagnosis is made either very late in the disease process or sometimes empirical therapy has to be started because a definite diagnosis could not be made. All of these are not ideal situations for a clinician. The present study was done with the aim to establish a rapid and reliable diagnosis of M. tuberculosis infection. This was established by identifying M. tuberculosis genes. METHODS The study was done on nine consecutive patients who presented with non-traumatic spontaneous vertebral compression collapse. CT-guided aspirate from the involved vertebra was subjected to Multiplex PCR (MPCR) using three primers: IS6110, protein b, and MPB 64. The aspirate was also subjected to smear and culture. The results of MPCR were compared with the final diagnosis. RESULTS Seven out of nine patients had a final diagnosis of tuberculosis. MPCR was positive in six of these seven patients, thus showing sensitivity of 85.7% and specificity of 100%. Results of MPCR were obtained within 24 h. CONCLUSIONS MPCR using IS6110, protein b, and MPB64 primers has a high sensitivity and specificity in rapid diagnosis of spinal tuberculosis. To the best of our knowledge, this has not been attempted before in spinal tuberculosis. This is particularly useful for paucibacillary infections like spinal tuberculosis. However, further studies using large sample sizes are needed to confirm the practical applicability of this technique.
Collapse
|
129
|
Chan JFW, Sridhar S, Yip CCY, Lau SKP, Woo PCY. The role of laboratory diagnostics in emerging viral infections: the example of the Middle East respiratory syndrome epidemic. J Microbiol 2017; 55:172-182. [PMID: 28243939 PMCID: PMC7090747 DOI: 10.1007/s12275-017-7026-y] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2017] [Accepted: 02/09/2017] [Indexed: 02/07/2023]
Abstract
Rapidly emerging infectious disease outbreaks place a great strain on laboratories to develop and implement sensitive and specific diagnostic tests for patient management and infection control in a timely manner. Furthermore, laboratories also play a role in real-time zoonotic, environmental, and epidemiological investigations to identify the ultimate source of the epidemic, facilitating measures to eventually control the outbreak. Each assay modality has unique pros and cons; therefore, incorporation of a battery of tests using traditional culture-based, molecular and serological diagnostics into diagnostic algorithms is often required. As such, laboratories face challenges in assay development, test evaluation, and subsequent quality assurance. In this review, we describe the different testing modalities available for the ongoing Middle East respiratory syndrome (MERS) epidemic including cell culture, nucleic acid amplification, antigen detection, and antibody detection assays. Applications of such tests in both acute clinical and epidemiological investigation settings are highlighted. Using the MERS epidemic as an example, we illustrate the various challenges faced by laboratories in test development and implementation in the setting of a rapidly emerging infectious disease. Future directions in the diagnosis of MERS and other emerging infectious disease investigations are also highlighted.
Collapse
|
130
|
Schwarz E. Identification and Clinical Translation of Biomarker Signatures: Statistical Considerations. Methods Mol Biol 2017; 1546:103-114. [PMID: 27896759 DOI: 10.1007/978-1-4939-6730-8_6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Powerful machine learning tools exist to extract biological patterns for diagnosis or prediction from high-dimensional datasets. Simultaneous advances in high-throughput profiling technologies have led to a rapid acceleration of biomarker discovery investigations across all areas of medicine. However, the translation of biomarker signatures into clinically useful tools has thus far been difficult. In this chapter, several important considerations are discussed that influence such translation in the context of classifier design. These include aspects of variable selection that go beyond classification accuracy, as well as effects of variability on assay stability and sample size. The consideration of such factors may lead to an adaptation of biomarker discovery approaches, aimed at an optimal balance of performance and clinical translatability.
Collapse
|
131
|
Cha E, Lee KM, Park KD, Park KS, Lee KW, Kim SM, Lee J. Hydroxycholesterol Levels in the Serum and Cerebrospinal Fluid of Patients with Neuromyelitis Optica Revealed by LC-Ag+CIS/MS/MS and LC-ESI/MS/MS with Picolinic Derivatization: Increased Levels and Association with Disability during Acute Attack. PLoS One 2016; 11:e0167819. [PMID: 27942009 PMCID: PMC5152860 DOI: 10.1371/journal.pone.0167819] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2016] [Accepted: 11/21/2016] [Indexed: 01/19/2023] Open
Abstract
Neuromyelitis optica (NMO) is an inflammatory demyelinating disease of the central nervous system (CNS). Hydroxycholesterols (OHCs), metabolites of CNS cholesterol, are involved in diverse cellular responses to inflammation and demyelination, and may also be involved in the pathogenesis of NMO. We aimed to develop a sensitive and reliable method for the quantitative analysis of three major OHCs (24S-, 25-, and 27-OHCs), and to evaluate their concentration in the cerebrospinal fluid (CSF) and serum of patients with NMO. The levels of the three OHCs in the serum and CSF were measured using liquid chromatography-silver ion coordination ionspray tandem mass spectrometry and liquid chromatography-electrospray ionization tandem mass spectrometry with picolinyl ester derivatization, respectively. The linear range was 5–250 ng/mL for 24S- and 27-OHC, and 0.5–25 ng/mL for 25-OHC in serum, and was 0.1–5 ng/mL for 24S- and 27-OHC, and 0.03–1 ng/mL for 25-OHC in CSF. Precision and accuracy were 0.5%–14.7% and 92.5%–109.7%, respectively, in serum, and were 0.8%–7.7% and 94.5%–119.2%, respectively, in CSF. Extraction recovery was 82.7%–90.7% in serum and 68.4%–105.0% in CSF. When analyzed in 26 NMO patients and 23 control patients, the 25-OHC (0.54 ± 0.96 ng/mL vs. 0.09 ± 0.04 ng/mL, p = 0.032) and 27-OHC (2.68 ± 3.18 ng/mL vs. 0.68 ± 0.25 ng/mL, p = 0.005) were increased in the CSF from NMO patients. When we measured the OHCCSF index that controls the effects of blood–brain barrier disruption on the level of OHC in the CSF, the 27-OHCCSF index was associated with disability (0.723; 95% confidence interval (CI)– 0.181, 0.620; p = 0.002), while the 24-OHCCSF index (0.518; 95% CI– 1.070, 38.121; p = 0.040) and 25-OHCCSF index (0.677; 95% CI– 4.313, 18.532; p = 0.004) were associated with the number of white blood cells in the CSF of NMO patients. Our results imply that OHCs in the CNS could play a role in the pathogenesis of NMO.
Collapse
|
132
|
Bartley AN, Washington MK, Ventura CB, Ismaila N, Colasacco C, Benson AB, Carrato A, Gulley ML, Jain D, Kakar S, Mackay HJ, Streutker C, Tang L, Troxell M, Ajani JA. HER2 Testing and Clinical Decision Making in Gastroesophageal Adenocarcinoma: Guideline From the College of American Pathologists, American Society for Clinical Pathology, and American Society of Clinical Oncology. Arch Pathol Lab Med 2016; 140:1345-1363. [PMID: 27841667 DOI: 10.5858/arpa.2016-0331-cp] [Citation(s) in RCA: 92] [Impact Index Per Article: 11.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
CONTEXT - ERBB2 (erb-b2 receptor tyrosine kinase 2 or HER2) is currently the only biomarker established for selection of a specific therapy for patients with advanced gastroesophageal adenocarcinoma (GEA). However, there are no comprehensive guidelines for the assessment of HER2 in patients with GEA. OBJECTIVES - To establish an evidence-based guideline for HER2 testing in patients with GEA, to formalize the algorithms for methods to improve the accuracy of HER2 testing while addressing which patients and tumor specimens are appropriate, and to provide guidance on clinical decision making. DESIGN - The College of American Pathologists, American Society for Clinical Pathology, and American Society of Clinical Oncology convened an expert panel to conduct a systematic review of the literature to develop an evidence-based guideline with recommendations for optimal HER2 testing in patients with GEA. RESULTS - The panel is proposing 11 recommendations with strong agreement from the open-comment participants. RECOMMENDATIONS - The panel recommends that tumor specimen(s) from all patients with advanced GEA, who are candidates for HER2-targeted therapy, should be assessed for HER2 status before the initiation of HER2-targeted therapy. Clinicians should offer combination chemotherapy and a HER2-targeted agent as initial therapy for all patients with HER2-positive advanced GEA. For pathologists, guidance is provided for morphologic selection of neoplastic tissue, testing algorithms, scoring methods, interpretation and reporting of results, and laboratory quality assurance. CONCLUSIONS - This guideline provides specific recommendations for assessment of HER2 in patients with advanced GEA while addressing pertinent technical issues and clinical implications of the results.
Collapse
|
133
|
Cong WM, Bu H, Chen J, Dong H, Zhu YY, Feng LH, Chen J, Committee G. Practice guidelines for the pathological diagnosis of primary liver cancer: 2015 update. World J Gastroenterol 2016; 22:9279-9287. [PMID: 27895416 PMCID: PMC5107692 DOI: 10.3748/wjg.v22.i42.9279] [Citation(s) in RCA: 242] [Impact Index Per Article: 30.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/01/2016] [Revised: 06/15/2016] [Accepted: 08/08/2016] [Indexed: 02/06/2023] Open
Abstract
In 2010, a panel of Chinese pathologists reported the first expert consensus for the pathological diagnosis of primary liver cancers to address the many contradictions and inconsistencies in the pathological characteristics and diagnostic criteria for PLC. Since then considerable clinicopathological studies have been conducted globally, prompting us to update the practice guidelines for the pathological diagnosis of PLC. In April 18, 2014, a Guideline Committee consisting of 40 specialists from seven Chinese Societies (including Chinese Society of Liver Cancer, Chinese Anti-Cancer Association; Liver Cancer Study Group, Chinese Society of Hepatology, Chinese Medical Association; Chinese Society of Pathology, Chinese Anti-Cancer Association; Digestive Disease Group, Chinese Society of Pathology, Chinese Medical Association; Chinese Society of Surgery, Chinese Medical Association; Chinese Society of Clinical Oncology, Chinese Anti-Cancer Association; Pathological Group of Hepatobiliary Tumor and Liver Transplantation, Chinese Society of Pathology, Chinese Medical Association) was created for the formulation of the first guidelines for the standardization of the pathological diagnosis of PLC, mainly focusing on the following topics: gross specimen sampling, concepts and diagnostic criteria of small hepatocellular carcinoma (SHCC), microvascular invasion (MVI), satellite nodules, and immunohistochemical and molecular diagnosis. The present updated guidelines are reflective of current clinicopathological studies, and include a novel 7-point baseline sampling protocol, which stipulate that at least four tissue specimens should be sampled at the junction of the tumor and adjacent liver tissues in a 1:1 ratio at the 12, 3, 6 and 9 o’clock reference positions. For the purposes of molecular pathological examination, at least one specimen should be sampled at the intratumoral zone, but more specimens should be sampled for tumors harboring different textures or colors. Specimens should be sampled at both adjacent and distant peritumoral liver tissues or the tumor margin in order to observe MVI, satellite nodules and dysplastic foci/nodules distributed throughout the background liver tissues. Complete sampling of whole SHCC ≤ 3 cm should be performed to assess its biological behavior, and in clinical practice, therapeutic borders should be also preserved, even in SHCC. The diagnostic criteria of MVI and satellite nodules, immunohistochemical panels, as well as molecular diagnostic principles, such as clonal typing, for recurrent HCC and multinodule HCC were also proposed and recommended. The standardized process of pathological examination is aimed at ensuring the accuracy of pathological PLC diagnoses as well as providing a valuable frame of reference for the clinical assessment of tumor invasive potential, the risk of postoperative recurrence, long-term survival, and the development of individualized treatment regimens. The updated guidelines could ensure the accuracy of pathological diagnoses of PLC, and provide a valuable frame of reference for its clinical assessment.
Collapse
|
134
|
Bachanek-Bankowska K, Mero HR, Wadsworth J, Mioulet V, Sallu R, Belsham GJ, Kasanga CJ, Knowles NJ, King DP. Development and evaluation of tailored specific real-time RT-PCR assays for detection of foot-and-mouth disease virus serotypes circulating in East Africa. J Virol Methods 2016; 237:114-120. [PMID: 27575682 DOI: 10.1016/j.jviromet.2016.08.002] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2016] [Revised: 07/26/2016] [Accepted: 08/01/2016] [Indexed: 11/27/2022]
Abstract
Rapid, reliable and accurate diagnostic methods provide essential support to programmes that monitor and control foot-and-mouth disease (FMD). While pan-specific molecular tests for FMD virus (FMDV) detection are well established and widely used in endemic and FMD-free countries, current serotyping methods mainly rely either on antigen detection ELISAs or nucleotide sequencing approaches. This report describes the development of a panel of serotype-specific real-time RT-PCR assays (rRT-PCR) tailored to detect FMDV lineages currently circulating in East Africa. These assays target sequences within the VP1-coding region that share high intra-lineage identity, but do not cross-react with FMD viruses from other serotypes that circulate in the region. These serotype-specific assays operate with the same thermal profile as the pan-diagnostic tests making it possible to run them in parallel to produce CT values comparable to the pan-diagnostic test detecting the 3D-coding region. These assays were evaluated alongside the established pan-specific molecular test using field samples and virus isolates collected from Tanzania, Kenya and Ethiopia that had been previously characterised by nucleotide sequencing. Samples (n=71) representing serotype A (topotype AFRICA, lineage G-I), serotype O (topotypes EA-2 and EA-4), serotype SAT 1 (topotype I (NWZ)) and serotype SAT2 (topotype IV) were correctly identified with these rRT-PCR assays. Furthermore, FMDV RNA from samples that did not contain infectious virus could still be serotyped using these assays. These serotype-specific real-time RT-PCR assays can detect and characterise FMDVs currently circulating in East Africa and hence improve disease control in this region.
Collapse
|
135
|
Camps C, Petousi N, Bento C, Cario H, Copley RR, McMullin MF, van Wijk R, Ratcliffe PJ, Robbins PA, Taylor JC. Gene panel sequencing improves the diagnostic work-up of patients with idiopathic erythrocytosis and identifies new mutations. Haematologica 2016; 101:1306-1318. [PMID: 27651169 PMCID: PMC5394871 DOI: 10.3324/haematol.2016.144063] [Citation(s) in RCA: 58] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2016] [Accepted: 07/26/2016] [Indexed: 12/31/2022] Open
Abstract
Erythrocytosis is a rare disorder characterized by increased red cell mass and elevated hemoglobin concentration and hematocrit. Several genetic variants have been identified as causes for erythrocytosis in genes belonging to different pathways including oxygen sensing, erythropoiesis and oxygen transport. However, despite clinical investigation and screening for these mutations, the cause of disease cannot be found in a considerable number of patients, who are classified as having idiopathic erythrocytosis. In this study, we developed a targeted next-generation sequencing panel encompassing the exonic regions of 21 genes from relevant pathways (~79 Kb) and sequenced 125 patients with idiopathic erythrocytosis. The panel effectively screened 97% of coding regions of these genes, with an average coverage of 450×. It identified 51 different rare variants, all leading to alterations of protein sequence, with 57 out of 125 cases (45.6%) having at least one of these variants. Ten of these were known erythrocytosis-causing variants, which had been missed following existing diagnostic algorithms. Twenty-two were novel variants in erythrocytosis-associated genes (EGLN1, EPAS1, VHL, BPGM, JAK2, SH2B3) and in novel genes included in the panel (e.g. EPO, EGLN2, HIF3A, OS9), some with a high likelihood of functionality, for which future segregation, functional and replication studies will be useful to provide further evidence for causality. The rest were classified as polymorphisms. Overall, these results demonstrate the benefits of using a gene panel rather than existing methods in which focused genetic screening is performed depending on biochemical measurements: the gene panel improves diagnostic accuracy and provides the opportunity for discovery of novel variants.
Collapse
|
136
|
Cloherty G, Chevaliez S, Sarrazin C, Herman C, Holzmayer V, Dawson G, Maasoumy B, Vermehren J, Wedemeyer H, Feld JJ, Pawlotsky JM. Hepatitis C RNA assay differences in results: Potential implications for shortened therapy and determination of Sustained Virologic Response. Sci Rep 2016; 6:35410. [PMID: 27762283 PMCID: PMC5071881 DOI: 10.1038/srep35410] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2016] [Accepted: 09/28/2016] [Indexed: 12/17/2022] Open
Abstract
Approval of Ledipasvir/Sofosbuvir for the treatment of chronic hepatitis C (HCV) includes the truncation of therapy from 12 to 8 weeks in treatment naïve, non-cirrhotic patients with baseline HCV RNA levels <6 million IU/mL (6.8 log10 IU/mL). The aim of this study was to evaluate this clinical cutoff with a different widely used commercially available HCV RNA test. Results from samples tested prospectively with Roche High Pure TaqMan HCV 2.0 test (HPS) were compared to those tested retrospectively with the Abbott RealTime HCV RNA test (ART). Using 6 million IU/mL as the cut-off, pre-treatment results were concordant in 70.4% of cases. When results with the same test measured at screening and baseline, clinical decisions could be impacted in 14.4% and 6.2% of cases for HPS and ART respectively. Using only HCV RNA cutoff of 6 million IU/mL, 29.55% of subjects would receive a different and potentially incorrect treatment duration based solely on HCV RNA test method used. A further 6-14% of subjects would have treatment decision change based on the day the sample was taken.
Collapse
|
137
|
Dittrich S, Tadesse BT, Moussy F, Chua A, Zorzet A, Tängdén T, Dolinger DL, Page AL, Crump JA, D’Acremont V, Bassat Q, Lubell Y, Newton PN, Heinrich N, Rodwell TJ, González IJ. Target Product Profile for a Diagnostic Assay to Differentiate between Bacterial and Non-Bacterial Infections and Reduce Antimicrobial Overuse in Resource-Limited Settings: An Expert Consensus. PLoS One 2016; 11:e0161721. [PMID: 27559728 PMCID: PMC4999186 DOI: 10.1371/journal.pone.0161721] [Citation(s) in RCA: 48] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2016] [Accepted: 08/09/2016] [Indexed: 11/30/2022] Open
Abstract
Acute fever is one of the most common presenting symptoms globally. In order to reduce the empiric use of antimicrobial drugs and improve outcomes, it is essential to improve diagnostic capabilities. In the absence of microbiology facilities in low-income settings, an assay to distinguish bacterial from non-bacterial causes would be a critical first step. To ensure that patient and market needs are met, the requirements of such a test should be specified in a target product profile (TPP). To identify minimal/optimal characteristics for a bacterial vs. non-bacterial fever test, experts from academia and international organizations with expertise in infectious diseases, diagnostic test development, laboratory medicine, global health, and health economics were convened. Proposed TPPs were reviewed by this working group, and consensus characteristics were defined. The working group defined non-severely ill, non-malaria infected children as the target population for the desired assay. To provide access to the most patients, the test should be deployable to community health centers and informal health settings, and staff should require <2 days of training to perform the assay. Further, given that the aim is to reduce inappropriate antimicrobial use as well as to deliver appropriate treatment for patients with bacterial infections, the group agreed on minimal diagnostic performance requirements of >90% and >80% for sensitivity and specificity, respectively. Other key characteristics, to account for the challenging environment at which the test is targeted, included: i) time-to-result <10 min (but maximally <2 hrs); ii) storage conditions at 0–40°C, ≤90% non-condensing humidity with a minimal shelf life of 12 months; iii) operational conditions of 5–40°C, ≤90% non-condensing humidity; and iv) minimal sample collection needs (50–100μL, capillary blood). This expert approach to define assay requirements for a bacterial vs. non-bacterial assay should guide product development, and enable targeted and timely efforts by industry partners and academic institutions.
Collapse
|
138
|
Chen YL, Lee CT, Lu CC, Yang SC, Chen WL, Lee YC, Yang CH, Peng SL, Su WC, Chow NH, Ho CL. Epidermal Growth Factor Receptor Mutation and Anaplastic Lymphoma Kinase Gene Fusion: Detection in Malignant Pleural Effusion by RNA or PNA Analysis. PLoS One 2016; 11:e0158125. [PMID: 27352172 PMCID: PMC4924845 DOI: 10.1371/journal.pone.0158125] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2016] [Accepted: 06/11/2016] [Indexed: 11/29/2022] Open
Abstract
Analyzing EGFR mutations and detecting ALK gene fusion are indispensable when planning to treat pulmonary adenocarcinoma. Malignant pleural effusion (MPE) is a devastating complication of lung cancer and sometimes the only source for mutation analysis. The percentage of tumor cells in the pleural effusion may be low; therefore, mutant enrichment is required for a successful analysis. The EGFR mutation status in MPE was determined using three methods: (1) PCR sequencing of genomic DNA (direct sequencing), (2) mutant-enriched PCR sequencing of genomic DNA using peptide nucleic acid (PNA-sequencing), and (3) PCR sequencing of cDNA after reverse transcription for cellular RNA (RNA-sequencing). RT-PCR was also used to test cases for ALK gene fusion. PNA-sequencing and RNA-sequencing had similar analytical sensitivities (< 1%), which indicates similar enrichment capabilities. The clinical sensitivity in 133 cases when detecting the common EGFR exon 19 and exon 21 mutations was 56.4% (75/133) for direct sequencing, 63.2% (84/133) for PNA-sequencing, and 65.4% (87/133) for RNA-sequencing. RT-PCR and sequencing showed 5 cases (3.8%) with ALK gene fusion. All had wild-type EGFR. For EGFR analysis of MPE, RNA-sequencing is at least as sensitive as PNA-sequencing but not limited to specific mutations. Detecting ALK fusion can be incorporated in the same RNA workflow. Therefore, RNA is a better source for comprehensive molecular diagnoses in MPE.
Collapse
|
139
|
Payne DA, Baluchova K, Peoc'h KH, van Schaik RHN, Chan KCA, Maekawa M, Mamotte C, Russomando G, Rousseau F, Ahmad-Nejad P. Pre-examination factors affecting molecular diagnostic test results and interpretation: A case-based approach. Clin Chim Acta 2016; 467:59-69. [PMID: 27321365 DOI: 10.1016/j.cca.2016.06.018] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2015] [Revised: 06/13/2016] [Accepted: 06/15/2016] [Indexed: 12/13/2022]
Abstract
BACKGROUND Multiple organizations produce guidance documents that provide opportunities to harmonize quality practices for diagnostic testing. The International Organization for Standardization ISO 15189 standard addresses requirements for quality in management and technical aspects of the clinical laboratory. One technical aspect addresses the complexities of the pre-examination phase prior to diagnostic testing. METHODS The Committee for Molecular Diagnostics of the International Federation for Clinical Chemistry and Laboratory Medicine (also known as, IFCC C-MD) conducted a survey of international molecular laboratories and determined ISO 15189 to be the most referenced guidance document. In this review, the IFCC C-MD provides case-based examples illustrating the value of select pre-examination processes as these processes relate to molecular diagnostic testing. Case-based examples in infectious disease, oncology, inherited disease and pharmacogenomics address the utility of: 1) providing information to patients and users, 2) designing requisition forms, 3) obtaining informed consent and 4) maintaining sample integrity prior to testing. CONCLUSIONS The pre-examination phase requires extensive and consistent communication between the laboratory, the healthcare provider and the end user. The clinical vignettes presented in this paper illustrate the value of applying select ISO 15189 recommendations for general laboratory to the more specialized area of Molecular Diagnostics.
Collapse
|
140
|
Porto G, Brissot P, Swinkels DW, Zoller H, Kamarainen O, Patton S, Alonso I, Morris M, Keeney S. EMQN best practice guidelines for the molecular genetic diagnosis of hereditary hemochromatosis (HH). Eur J Hum Genet 2016; 24:479-95. [PMID: 26153218 PMCID: PMC4929861 DOI: 10.1038/ejhg.2015.128] [Citation(s) in RCA: 51] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2014] [Revised: 04/29/2015] [Accepted: 05/06/2015] [Indexed: 12/14/2022] Open
Abstract
Molecular genetic testing for hereditary hemochromatosis (HH) is recognized as a reference test to confirm the diagnosis of suspected HH or to predict its risk. The vast majority (typically >90%) of patients with clinically characterized HH are homozygous for the p.C282Y variant in the HFE gene, referred to as HFE-related HH. Since 1996, HFE genotyping was implemented in diagnostic algorithms for suspected HH, allowing its early diagnosis and prevention. However, the penetrance of disease in p.C282Y homozygotes is incomplete. Hence, homozygosity for p.C282Y is not sufficient to diagnose HH. Neither is p.C282Y homozygosity required for diagnosis as other rare forms of HH exist, generally referred to as non-HFE-related HH. These pose significant challenges when defining criteria for referral, testing protocols, interpretation of test results and reporting practices. We present best practice guidelines for the molecular genetic diagnosis of HH where recommendations are classified, as far as possible, according to the level and strength of evidence. For clarification, the guidelines' recommendations are preceded by a detailed description of the methodology and results obtained with a series of actions taken in order to achieve a wide expert consensus, namely: (i) a survey on the current practices followed by laboratories offering molecular diagnosis of HH; (ii) a systematic literature search focused on some identified controversial topics; (iii) an expert Best Practice Workshop convened to achieve consensus on the practical recommendations included in the guidelines.
Collapse
|
141
|
Zhang SQ, Catenacci DVT. How can next-generation diagnostics aid pancreatic adenocarcinoma treatment? Future Oncol 2016; 12:585-8. [PMID: 26831761 DOI: 10.2217/fon.15.353] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022] Open
|
142
|
Beal SG, Assarzadegan N, Rand KH. Sample-to-result molecular infectious disease assays: clinical implications, limitations and potential. Expert Rev Mol Diagn 2016; 16:323-41. [PMID: 26689497 PMCID: PMC7103687 DOI: 10.1586/14737159.2016.1134325] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2015] [Accepted: 12/17/2015] [Indexed: 01/01/2023]
Abstract
Molecular infectious disease diagnostic tests have undergone major advances in the past decade and will continue to rapidly evolve. Assays have become extraordinarily simple to perform, eliminating the need for pre-analytic sample preparation and post-amplification analysis. This allows these tests to be performed in settings without sophisticated expertise in molecular biology, including locations with limited resources. Additionally, the sensitivity and specificity of these assays is superb and many offer extremely fast turn-around times. These tests have major impacts on patient care, but also have some limitations.
Collapse
|
143
|
Richman SD, Adams R, Quirke P, Butler R, Hemmings G, Chambers P, Roberts H, James MD, Wozniak S, Bathia R, Pugh C, Maughan T, Jasani B. Pre-trial inter-laboratory analytical validation of the FOCUS4 personalised therapy trial. J Clin Pathol 2016; 69:35-41. [PMID: 26350752 PMCID: PMC4717430 DOI: 10.1136/jclinpath-2015-203097] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2015] [Accepted: 07/03/2015] [Indexed: 01/22/2023]
Abstract
INTRODUCTION Molecular characterisation of tumours is increasing personalisation of cancer therapy, tailored to an individual and their cancer. FOCUS4 is a molecularly stratified clinical trial for patients with advanced colorectal cancer. During an initial 16-week period of standard first-line chemotherapy, tumour tissue will undergo several molecular assays, with the results used for cohort allocation, then randomisation. Laboratories in Leeds and Cardiff will perform the molecular testing. The results of a rigorous pre-trial inter-laboratory analytical validation are presented and discussed. METHODS Wales Cancer Bank supplied FFPE tumour blocks from 97 mCRC patients with consent for use in further research. Both laboratories processed each sample according to an agreed definitive FOCUS4 laboratory protocol, reporting results directly to the MRC Trial Management Group for independent cross-referencing. RESULTS Pyrosequencing analysis of mutation status at KRAS codons12/13/61/146, NRAS codons12/13/61, BRAF codon600 and PIK3CA codons542/545/546/1047, generated highly concordant results. Two samples gave discrepant results; in one a PIK3CA mutation was detected only in Leeds, and in the other, a PIK3CA mutation was only detected in Cardiff. pTEN and mismatch repair (MMR) protein expression was assessed by immunohistochemistry (IHC) resulting in 6/97 discordant results for pTEN and 5/388 for MMR, resolved upon joint review. Tumour heterogeneity was likely responsible for pyrosequencing discrepancies. The presence of signet-ring cells, necrosis, mucin, edge-effects and over-counterstaining influenced IHC discrepancies. CONCLUSIONS Pre-trial assay analytical validation is essential to ensure appropriate selection of patients for targeted therapies. This is feasible for both mutation testing and immunohistochemical assays and must be built into the workup of such trials. TRIAL REGISTRATION NUMBER ISRCTN90061564.
Collapse
|
144
|
Shi D, Shen S, Fan X, Chen S, Wang D, Li C, Wu X, Li L, Bai D, Zhang C, Wang J. Evaluation of Commercial Diagnostic Assays for the Specific Detection of Avian Influenza A (H7N9) Virus RNA Using a Quality-Control Panel and Clinical Specimens in China. PLoS One 2015; 10:e0137862. [PMID: 26361351 PMCID: PMC4567293 DOI: 10.1371/journal.pone.0137862] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2015] [Accepted: 08/23/2015] [Indexed: 11/18/2022] Open
Abstract
A novel avian influenza A H7N9-subtype virus emerged in China in 2013 and threatened global public health. Commercial kits that specifically detect avian influenza A (H7N9) virus RNA are urgently required to prepare for the emergence and potential pandemic of this novel influenza virus. The safety and effectiveness of three commercial molecular diagnostic assays were evaluated using a quality-control panel and clinical specimens collected from over 90 patients with confirmed avian influenza A (H7N9) virus infections. The analytical performance evaluation showed that diverse influenza H7N9 viruses can be detected with high within- and between-lot reproducibility and without cross-reactivity to other influenza viruses (H1N1 pdm09, seasonal H1N1, H3N2, H5N1 and influenza B). The detection limit of all the commercial assays was 2.83 Log10 copies/μl [0.7 Log10TCID50/mL of avian influenza A (H7N9) virus strain A/Zhejiang/DTID-ZJU01/2013], which is comparable to the method recommended by the World Health Organization (WHO). In addition, using a WHO-Chinese National Influenza Center (CNIC) method as a reference for clinical evaluation, positive agreement of more than 98% was determined for all of the commercial kits, while negative agreement of more than 99% was observed. In conclusion, our findings provide comprehensive evidence for the high performance of three commercial diagnostic assays and suggest the application of these assays as rapid and effective diagnostic tools for avian influenza A (H7N9) virus in the routine clinical practice of medical laboratories.
Collapse
|
145
|
Miyachi H. [Development of Standards for Baseline Quality in Quality Management of Molecular-Diagnostic Testing]. RINSHO BYORI. THE JAPANESE JOURNAL OF CLINICAL PATHOLOGY 2015; 63:823-831. [PMID: 26591433] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
As molecular-diagnostic testing is expanding in clinical use, the demand for its quality assurance is increasing. To this end, efforts towards quality management have been made regionally and globally. An entire testing procedure needs to be properly performed from the preanalytic, analytic, and postanalytic processes. Particularly, the preanalytic process largely affects the measurement and, thus, the result. The Japanese Committee for Clinical Laboratory and Standard developed the standard documents, such as that for the quality management of clinical specimens and best-practice guideline for quality assurance of molecular-genetic testing. These standard documents would provide not only the requirements as the best practice for testing, but also the basis of baseline quality and reliability. They can be used as the basis for assessment of the quality of practice in reimbursement coverage by payers and in certification or accreditation by a third party.
Collapse
|
146
|
Langabeer SE. Lack of National Consensus for the Molecular Investigation of Myeloproliferative Neoplasms. IRISH MEDICAL JOURNAL 2015; 108:189-190. [PMID: 26182811] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
|
147
|
Cayuela JM, Mauté C, Fabre AL, Nibourel O, Dulucq S, Delabesse E, Villarèse P, Hayette S, Mozziconacci MJ, Macintyre E. A novel method for room temperature distribution and conservation of RNA and DNA reference materials for guaranteeing performance of molecular diagnostics in onco-hematology: A GBMHM study. Clin Biochem 2015; 48:982-7. [PMID: 25872147 DOI: 10.1016/j.clinbiochem.2015.04.004] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2015] [Revised: 03/05/2015] [Accepted: 04/05/2015] [Indexed: 11/19/2022]
Abstract
OBJECTIVES Performance of methods used for molecular diagnostics must be closely controlled by regular analysis of internal quality controls. However, conditioning, shipping and long lasting storage of nucleic acid controls remain problematic. Therefore, we evaluated the minicapsule-based innovative process developed by Imagene (Evry, France) for implementing DNA and RNA controls designed for clonality assessment of lymphoproliferations and BCR-ABL1 mRNA quantification, respectively. DESIGN & METHODS DNA samples were extracted from 12 cell lines selected for giving specific amplifications with most BIOMED-2 PCR tubes. RNA samples were extracted from 8 cell line mixtures expressing various BCR-ABL1 transcript levels. DNA and RNA were encapsulated by Imagene and shipped at room temperature to participating laboratories. Biologists were asked to report quality data of recovered nucleic acids as well as PCR results. RESULTS Encapsulated nucleic acids samples were easily and efficiently recovered from minicapsules. The expected rearrangements at immunoglobulin, T-cell receptor and BCL2 loci were detected in DNA samples by all laboratories. Quality of RNA was consistent between laboratories and met the criteria requested for quantification of BCR-ABL1 transcripts. Expression levels measured by the 5 laboratories were within ±2 fold interval from the corresponding pre-encapsulation reference value. Moreover aging studies of encapsulated RNA simulating up to 100 years storage at room temperature show no bias in quantitative outcome. CONCLUSIONS Therefore, Imagene minicapsules are suitable for storage and distribution at room temperature of genetic material designed for proficiency control of molecular diagnostic methods based on end point or real-time quantitative PCR.
Collapse
MESH Headings
- Cell Line
- Cell Line, Tumor
- DNA/analysis
- DNA/metabolism
- DNA/standards
- Feasibility Studies
- France
- Fusion Proteins, bcr-abl/blood
- Fusion Proteins, bcr-abl/genetics
- Fusion Proteins, bcr-abl/metabolism
- Genetic Testing/standards
- Hematology/methods
- Humans
- Laboratory Proficiency Testing
- Leukemia, Myelogenous, Chronic, BCR-ABL Positive/blood
- Leukemia, Myelogenous, Chronic, BCR-ABL Positive/diagnosis
- Leukemia, Myelogenous, Chronic, BCR-ABL Positive/genetics
- Lymphoproliferative Disorders/blood
- Lymphoproliferative Disorders/diagnosis
- Lymphoproliferative Disorders/genetics
- Medical Oncology/methods
- Molecular Diagnostic Techniques/standards
- Pilot Projects
- Plasma/chemistry
- Quality Control
- RNA/analysis
- RNA/metabolism
- RNA/standards
- RNA Stability
- RNA, Messenger/blood
- RNA, Messenger/metabolism
- Reference Standards
- Temperature
Collapse
|
148
|
Kozlovac J, Schmitt B. Biosafety principles and practices for the veterinary diagnostic laboratory. Methods Mol Biol 2015; 1247:31-41. [PMID: 25399086 DOI: 10.1007/978-1-4939-2004-4_3] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
Good biosafety and biocontainment programs and practices are critical components of the successful operation of any veterinary diagnostic laboratory. In this chapter we provide information and guidance on critical biosafety management program elements, facility requirements, protective equipment, and procedures necessary to ensure that the laboratory worker and the environment are adequately protected in the challenging work environment of the veterinary diagnostic laboratory in general and provide specific guidance for those laboratories employing molecular diagnostic techniques.
Collapse
|
149
|
Thong KL, Teh CSJ, Chua KH. Development and evaluation of a Multiplex Polymerase Chain Reaction for the detection of Salmonella species. Trop Biomed 2014; 31:689-697. [PMID: 25776594] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
The present study aims to develop a system which consists of four pairs of primers that specifically detects Salmonella spp., Salmonella serovar Typhi and Salmonella serovar Paratyphi A with an internal amplification control. The system, when applied in Polymerase Chain Reaction (PCR) under specific conditions, reaction mixture and cycling temperatures produced four bands; 784 bp, 496 bp, 332 bp and 187 bp. The DNA band 784 bp is present in all Salmonella spp., while the bands of 496 bp and 332 bp are only present in S. Paratyphi A and S. Typhi, respectively. An internal amplification control as indicated by the 187 bp shows the system is working in optimum condition in all the tests. This multiplex PCR was evaluated on 241 bacterial cultures and 691 naturally contaminated samples. Overall, this multiplex PCR detection system provides a single step for simultaneous detection of DNAs of Salmonella spp., S. Typhi and S. Paratyphi A.
Collapse
|
150
|
Dumoulin A. [Molecular diagnostics of infectious diseases for the ambulatory practice]. REVUE MEDICALE SUISSE 2014; 10:1866-1870. [PMID: 25417356] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
Molecular diagnostics methods are not limited to specialized centers anymore. They play an important role for the diagnostic of infections commonly encountered in the clinical practice. Especially the detection of pathogens difficult to cultivate, such as viruses, has been greatly improved by these methods. Often, PCR has become the gold standard for the diagnostics of these pathogens. However, PCR cannot be used in any case, and it is not fail proof. Therefore, it is important to know when to use molecular methods and what are their strengths and weaknesses, in order to prescribe them rationally. This article reviews the characteristics of molecular tests and their main indications in the ambulatory setting.
Collapse
|