51
|
Koposova EA, Offenhäusser A, Ermolenko YE, Mourzina YG. Photoresponsive Porphyrin Nanotubes of Meso-tetra(4-Sulfonatophenyl)Porphyrin and Sn(IV) meso-tetra(4-pyridyl)porphyrin. Front Chem 2019; 7:351. [PMID: 31157213 PMCID: PMC6532121 DOI: 10.3389/fchem.2019.00351] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2019] [Accepted: 04/29/2019] [Indexed: 11/13/2022] Open
Abstract
Porphyrin macrocycles and their supramolecular nanoassemblies are being widely explored in energy harvesting, sensor development, catalysis, and medicine because of a good tunability of their light-induced charge separation and electron/energy transfer properties. In the present work, we prepared and studied photoresponsive porphyrin nanotubes formed by the self-assembly of meso-tetrakis(4-sulfonatophenyl)porphyrin and Sn(IV) meso-tetra(4-pyridyl)porphyrin. Scanning electron microscopy and transmission electron microscopy showed that these tubular nanostructures were hollow with open ends and their length was 0.4–0.8 μm, the inner diameter was 7–15 nm, and the outer diameter was 30–70 nm. Porphyrin tectons, H4TPPS42- : Sn(IV)TPyP4+, self-assemble into the nanotubes in a ratio of 2:1, respectively, as determined by the elemental analysis. The photoconductivity of the porphyrin nanotubes was determined to be as high as 3.1 × 10−4 S m−1, and the dependence of the photoconductance on distance and temperature was investigated. Excitation of the Q-band region with a Q-band of SnTPyP4+ (550–552 nm) and the band at 714 nm, which is associated with J-aggregation, was responsible for about 34 % of the photoconductive activity of the H4TPPS42--Sn(IV)TPyP4+ porphyrin nanotubes. The sensor properties of the H4TPPS42-- Sn(IV)TPyP4+ nanotubes in the presence of iodine vapor and salicylate anions down to millimolar range were examined in a chemiresistor sensing mode. We have shown that the porphyrin nanotubes advantageously combine the characteristics of a sensor and a transducer, thus demonstrating their great potential as efficient functional layers for sensing devices and biomimetic nanoarchitectures.
Collapse
|
52
|
Rincón Montes V, Gehlen J, Lück S, Mokwa W, Müller F, Walter P, Offenhäusser A. Toward a Bidirectional Communication Between Retinal Cells and a Prosthetic Device - A Proof of Concept. Front Neurosci 2019; 13:367. [PMID: 31114470 PMCID: PMC6502975 DOI: 10.3389/fnins.2019.00367] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2018] [Accepted: 04/01/2019] [Indexed: 01/15/2023] Open
Abstract
Background: Significant progress toward the recovery of useful vision in blind patients with severe degenerative retinal diseases caused by photoreceptor death has been achieved with the development of visual prostheses that stimulate the retina electrically. However, currently used prostheses do not provide feedback about the retinal activity before and upon stimulation and do not adjust to changes during the remodeling processes in the retina. Both features are desirable to improve the efficiency of the electrical stimulation (ES) therapy offered by these devices. Accordingly, devices that not only enable ES but at the same time provide information about the retinal activity are beneficial. Given the above, a bidirectional communication strategy, in which inner retinal cells are stimulated and the output neurons of the retina, the ganglion cells, are recorded using penetrating microelectrode arrays (MEAs) is proposed. Methods: Custom-made penetrating MEAs with four silicon-based shanks, each one with three or four iridium oxide electrodes specifically designed to match retinal dimensions were used to record the activity of light-adapted wildtype mice retinas and degenerated retinas from rd10 mice in vitro. In addition, responses to high potassium concentration and to light stimulation in wildtype retinas were examined. Furthermore, voltage-controlled ES was performed. Results: The spiking activity of retinal ganglion cells (RGCs) was recorded at different depths of penetration inside the retina. Physiological responses during an increase of the extracellular potassium concentration and phasic and tonic responses during light stimulation were captured. Moreover, pathologic rhythmic activity was recorded from degenerated retinas. Finally, ES of the inner retina and simultaneous recording of the activity of RGCs was accomplished. Conclusion: The access to different layers of the retina with penetrating electrodes while recording at the same time the spiking activity of RGCs broadens the use and the field of action of multi-shank and multi-site penetrating MEAs for retinal applications. It enables a bidirectional strategy to stimulate inner retinal cells electrically and to record from the spiking RGCs simultaneously (BiMEA). This opens the possibility of a feedback loop system to acknowledge the success of ES carried out by retinal prostheses.
Collapse
|
53
|
Kireev D, Rincón Montes V, Stevanovic J, Srikantharajah K, Offenhäusser A. N 3-MEA Probes: Scooping Neuronal Networks. Front Neurosci 2019; 13:320. [PMID: 31024239 PMCID: PMC6467947 DOI: 10.3389/fnins.2019.00320] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2018] [Accepted: 03/20/2019] [Indexed: 11/18/2022] Open
Abstract
In the current work, we introduce a brand new line of versatile, flexible, and multifunctional MEA probes, the so-called Nano Neuro Net, or N3-MEAs. Material choice, dimensions, and room for further upgrade, were carefully considered when designing such probes in order to cover the widest application range possible. Proof of the operation principle of these novel probes is shown in the manuscript via the recording of extracellular signals, such as action potentials and local field potentials from cardiac cells and retinal ganglion cells of the heart tissue and eye respectively. Reasonably large signal to noise ratio (SNR) combined with effortless operation of the devices, mechanical and chemical stability, multifunctionality provide, in our opinion, an unprecedented blend. We show successful recordings of (1) action potentials from heart tissue with a SNR up to 13.2; (2) spontaneous activity of retinal ganglion cells with a SNR up to 12.8; and (3) local field potentials with an ERG-like waveform, as well as spiking responses of the retina to light stimulation. The results reveal not only the multi-functionality of these N3-MEAs, but high quality recordings of electrogenic tissues.
Collapse
|
54
|
Zhang W, Liu H, Lu J, Ni L, Liu H, Li Q, Qiu M, Xu B, Lee T, Zhao Z, Wang X, Wang M, Wang T, Offenhäusser A, Mayer D, Hwang WT, Xiang D. Atomic switches of metallic point contacts by plasmonic heating. LIGHT, SCIENCE & APPLICATIONS 2019; 8:34. [PMID: 30937165 PMCID: PMC6437168 DOI: 10.1038/s41377-019-0144-z] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/05/2019] [Revised: 03/01/2019] [Accepted: 03/03/2019] [Indexed: 05/14/2023]
Abstract
Electronic switches with nanoscale dimensions satisfy an urgent demand for further device miniaturization. A recent heavily investigated approach for nanoswitches is the use of molecular junctions that employ photochromic molecules that toggle between two distinct isoforms. In contrast to the reports on this approach, we demonstrate that the conductance switch behavior can be realized with only a bare metallic contact without any molecules under light illumination. We demonstrate that the conductance of bare metallic quantum contacts can be reversibly switched over eight orders of magnitude, which substantially exceeds the performance of molecular switches. After the switch process, the gap size between two electrodes can be precisely adjusted with subangstrom accuracy by controlling the light intensity or polarization. Supported by simulations, we reveal a more general and straightforward mechanism for nanoswitching behavior, i.e., atomic switches can be realized by the expansion of nanoelectrodes due to plasmonic heating.
Collapse
|
55
|
Allmendinger F, Engin I, Grasdijk O, Heil W, Jungmann K, Karpuk S, Krause HJ, Niederländer B, Offenhäusser A, Repetto M, Schmidt U, Willmann L, Zimmer S. A new limit of the 129Xenon Electric Dipole Moment. EPJ WEB OF CONFERENCES 2019. [DOI: 10.1051/epjconf/201921902003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
We report on the first preliminary result of our 129Xe EDM measurement performed by the MIXed collaboration. The aim of this report is to demonstrate the feasibility of a new method to set limits on nuclear EDMs by investigating the EDM of the diamagnetic 129Xe atoms. In our setup, hyperpolarized 3He serves as a comagnetometer needed to suppress magnetic field fluctuations. The free induction decay of the two polarized spin species is directly measured by low noise DC SQUIDs, and the weighted phase difference extracted from these measurements is used to determine a preliminary upper limit on the 129Xe EDM.
Collapse
|
56
|
Niederländer B, Blümler P, Brotin T, van Dusschoten D, Offenhäusser A, Krause HJ, Heil W. Optimized Continuous Application of Hyperpolarized Xenon to Liquids. J Phys Chem A 2018; 122:9359-9369. [PMID: 30403866 DOI: 10.1021/acs.jpca.8b09479] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
In recent years, NMR with hyperpolarized (HP) xenon inside functionalized host structures (e.g., cryptophanes) have become a potential candidate for the direct observation of metabolic processes (i.e., molecular imaging). A critical issue for real applications is the dissolution of the HP-gas in the liquid which contains the host. In this work, we present recent developments for an improved and controlled dissolution of HP-Xe in liquids using hollow fiber membranes and different compressor systems. The designed apparatus consists of a compressor and a membrane unit. The compressor provides HP-129Xe continuously at small adjustable pressures and in a polarization-preserving way. The membrane unit enables a molecular solution of the HP-gas in aqueous liquids, avoiding the formation of bubbles or even foams. Two different types of compressors were tested in terms of function and useful materials. Special emphasis was put on a systematic reduction of transfer losses in the gas and liquid phase. In order to optimize the system parameters, several physical models were developed to describe the transport and the losses of nuclear polarization. Finally, the successful implementation was demonstrated in several experiments. HP-Xe was dissolved in an aqueous cryptophane-A-(OCH2COOH)6 solution, and stable Xe signals could be measured over 35 min, only limited by the size of the gas reservoir. Such long and stable experimental conditions enabled the study of chemical exchange of xenon between cryptophane and water environments even for a time-consuming 2D NMR experiment. The good signal stability over the measurement time allowed an exact determination of the residence time of the Xe atom inside the cryptophane, resulting in an average residence time of 44.5 ± 2.7 ms.
Collapse
|
57
|
Liang Y, Ernst M, Brings F, Kireev D, Maybeck V, Offenhäusser A, Mayer D. High Performance Flexible Organic Electrochemical Transistors for Monitoring Cardiac Action Potential. Adv Healthc Mater 2018; 7:e1800304. [PMID: 30109770 DOI: 10.1002/adhm.201800304] [Citation(s) in RCA: 30] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2018] [Revised: 04/30/2018] [Indexed: 11/08/2022]
Abstract
Flexible and transparent electronic devices possess crucial advantages over conventional silicon based systems for bioelectronic applications since they are able to adapt to nonplanar surfaces, cause less chronic immunoreactivity, and facilitate easy optical inspection. Here, organic electrochemical transistors (OECTs) are embedded in a flexible matrix of polyimide to record cardiac action potentials. The wafer-scale fabricated devices exhibit transconductances (12 mS V-1 ) and drain-source on-to-off current ratios (≈105 ) comparable to state of the art nonflexible and superior to other reported flexible OECTs. The transfer characteristics of the devices are preserved even after experiencing extremely high bending strain and harsh crumpling. A sub-micrometer poly(3,4-ethylenedioxythiophene) doped with poly(styrenesulfonate) layer results in a fast transport of ions between the electrolyte and the polymer channel characterized by a cut-off frequency of 1200 Hz. Excellent device performance is proved by mapping the propagation of cardiac action potentials with high signal-to-noise ratio. These results demonstrate that the electrical performance of flexible OECTs can compete with hard-material-based OECTs and thus potentially be used for in vivo applications.
Collapse
|
58
|
Zhang P, Lyu Z, Viktorova J, Offenhäusser A, Feng L, Mayer D. Nanoparticle stripe sensor for highly sensitive and selective detection of mercury ions. Biosens Bioelectron 2018; 117:450-456. [DOI: 10.1016/j.bios.2018.06.029] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2018] [Revised: 06/08/2018] [Accepted: 06/18/2018] [Indexed: 10/28/2022]
|
59
|
Kreysing E, Hassani H, Hampe N, Offenhäusser A. Nanometer-Resolved Mapping of Cell-Substrate Distances of Contracting Cardiomyocytes Using Surface Plasmon Resonance Microscopy. ACS NANO 2018; 12:8934-8942. [PMID: 30180539 DOI: 10.1021/acsnano.8b01396] [Citation(s) in RCA: 30] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
It has been shown that quantitative measurements of the cell-substrate distance of steady cells are possible with scanning surface plasmon resonance microscopy setups in combination with an angle resolved analysis. However, the accuracy of the determined cell-substrate distances as well as the capabilities for the investigation of cell dynamics remained limited due to the assumption of a homogeneous refractive index of the cytosol. Strong spatial or temporal deviations between the local refractive index and the average value can result in errors in the calculated cell-substrate distance of around 100 nm, while the average accuracy was determined to 37 nm. Here, we present a combination of acquisition and analysis techniques that enables the measurement of the cell-substrate distance of contractile cells as well as the study of intracellular processes through changes in the refractive index at the diffraction limit. By decoupling the measurement of the cell-substrate distance and the refractive index of the cytoplasm, we could increase the accuracy of the distance measurement on average by a factor of 25 reaching 1.5 nm under ideal conditions. We show a temporal and spatial mapping of changes in the refractive index and the cell-substrate distance which strongly correlate with the action potentials and reconstruct the three-dimensional profile of the basal cell membrane and its dynamics, while we reached an actual measurement accuracy of 2.3 nm.
Collapse
|
60
|
Koposova EA, Ermolenko YE, Offenhäusser A, Mourzina YG. Self-assembly and photoconductivity of binary porphyrin nanostructures of meso -tetrakis(4-sulfonatophenyl)porphine and Co(III) meso -tetra(4-pyridyl)porphine chloride. Colloids Surf A Physicochem Eng Asp 2018. [DOI: 10.1016/j.colsurfa.2018.03.053] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
61
|
Nikolaev KG, Ermolenko YE, Offenhäusser A, Ermakov SS, Mourzina YG. Multisensor Systems by Electrochemical Nanowire Assembly for the Analysis of Aqueous Solutions. Front Chem 2018; 6:256. [PMID: 30009159 PMCID: PMC6034576 DOI: 10.3389/fchem.2018.00256] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2018] [Accepted: 06/08/2018] [Indexed: 02/04/2023] Open
Abstract
The development of electrochemical multisensor systems is driven by the need for fast, miniature, inexpensive, analytical devices, and advanced interdisciplinary based on both chemometric and (nano)material approaches. A multicomponent analysis of complex mixtures in environmental and technological monitoring, biological samples, and cell culture requires chip-based multisensor systems with high-stability sensors. In this paper, we describe the development, characterization, and applications of chip-based nanoelectrochemical sensor arrays prepared by the directed electrochemical nanowire assembly (DENA) of noble metals and metal alloys to analyze aqueous solutions. A synergic action of the electrode transducer function and electrocatalytic activity of the nanostructured surface toward analytes is achieved in the assembled metal nanowire (NW) sensors. Various sensor nanomaterials (Pd, Ni, Au, and their multicomponent compositions) can be electrochemically assembled on a single chip without employing multiple cycles of photolithography process to realize multi-analyte sensing applications as well as spatial resolution of sensor analysis by this single-chip multisensor system. For multi-analyte electrochemical sensing, individual amperometric signals of two or more nanowires can be acquired, making use of the specific electrocatalytic surface properties of the individual nanowire sensors of the array toward analytes. To demonstrate the application of a new electrochemical multisensor platform, Pd-Au, Pd-Ni, Pd, and Au NW electrode arrays on a single chip were employed for the non-enzymatic analysis of hydrogen peroxide, glucose, and ethanol. The analytes are determined at low absolute values of the detection potentials with linear concentration ranges of 1.0 × 10−6 − 1.0 × 10−3 M (H2O2), 1.5 × 10−7 − 2.0 × 10−3 M (glucose), and 0.7 × 10−3 − 3.0 × 10−2 M (ethanol), detection limits of 2 × 10−7 M (H2O2), 4 × 10−8 M (glucose), and 5.2 × 10−4 M (ethanol), and sensitivities of 18 μA M−1 (H2O2), 178 μA M−1 (glucose), and 28 μA M−1 (ethanol), respectively. The sensors demonstrate a high level of stability due to the non-enzymatic detection mode. Based on the DENA-assembled nanowire electrodes of a compositional diversity, we propose a novel single-chip electrochemical multisensor platform, which is promising for acquiring complex analytical signals for advanced data processing with chemometric techniques aimed at the development of electronic tongue-type multisensor systems for flexible multi-analyte monitoring and healthcare applications.
Collapse
|
62
|
Markov A, Maybeck V, Wolf N, Mayer D, Offenhäusser A, Wördenweber R. Engineering of Neuron Growth and Enhancing Cell-Chip Communication via Mixed SAMs. ACS APPLIED MATERIALS & INTERFACES 2018; 10:18507-18514. [PMID: 29763286 DOI: 10.1021/acsami.8b02948] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
The interface between cells and inorganic surfaces represents one of the key elements for bioelectronics experiments and applications ranging from cell cultures and bioelectronics devices to medical implants. In the present paper, we describe a way to tailor the biocompatibility of substrates in terms of cell growth and to significantly improve cell-chip communication, and we also demonstrate the reusability of the substrates for cell experiments. All these improvements are achieved by coating the substrates or chips with a self-assembled monolayer (SAM) consisting of a mixture of organic molecules, (3-aminopropyl)-triethoxysilane and (3-glycidyloxypropyl)-trimethoxysilane. By varying the ratio of these molecules, we are able to tune the cell density and live/dead ratios of rat cortical neurons cultured directly on the mixed SAM as well as neurons cultured on protein-coated SAMs. Furthermore, the use of the SAM leads to a significant improvement in cell-chip communications. Action potential signals of up to 9.4 ± 0.6 mV (signal-to-noise ratio up to 47) are obtained for HL-1 cells on microelectrode arrays. Finally, we demonstrate that the SAMs facilitate a reusability of the samples for all cell experiments with little re-processing.
Collapse
|
63
|
Rabehi A, Garlan B, Achtsnicht S, Krause HJ, Offenhäusser A, Ngo K, Neveu S, Graff-Dubois S, Kokabi H. Magnetic Detection Structure for Lab-on-Chip Applications Based on the Frequency Mixing Technique. SENSORS (BASEL, SWITZERLAND) 2018; 18:E1747. [PMID: 29844260 PMCID: PMC6021809 DOI: 10.3390/s18061747] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/17/2018] [Revised: 05/17/2018] [Accepted: 05/22/2018] [Indexed: 01/24/2023]
Abstract
A magnetic frequency mixing technique with a set of miniaturized planar coils was investigated for use with a completely integrated Lab-on-Chip (LoC) pathogen sensing system. The system allows the detection and quantification of superparamagnetic beads. Additionally, in terms of magnetic nanoparticle characterization ability, the system can be used for immunoassays using the beads as markers. Analytical calculations and simulations for both excitation and pick-up coils are presented; the goal was to investigate the miniaturization of simple and cost-effective planar spiral coils. Following these calculations, a Printed Circuit Board (PCB) prototype was designed, manufactured, and tested for limit of detection, linear response, and validation of theoretical concepts. Using the magnetic frequency mixing technique, a limit of detection of 15 µg/mL of 20 nm core-sized nanoparticles was achieved without any shielding.
Collapse
|
64
|
Tran DP, Pham TTT, Wolfrum B, Offenhäusser A, Thierry B. CMOS-Compatible Silicon Nanowire Field-Effect Transistor Biosensor: Technology Development toward Commercialization. MATERIALS (BASEL, SWITZERLAND) 2018; 11:E785. [PMID: 29751688 PMCID: PMC5978162 DOI: 10.3390/ma11050785] [Citation(s) in RCA: 50] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/15/2018] [Revised: 05/08/2018] [Accepted: 05/10/2018] [Indexed: 12/22/2022]
Abstract
Owing to their two-dimensional confinements, silicon nanowires display remarkable optical, magnetic, and electronic properties. Of special interest has been the development of advanced biosensing approaches based on the field effect associated with silicon nanowires (SiNWs). Recent advancements in top-down fabrication technologies have paved the way to large scale production of high density and quality arrays of SiNW field effect transistor (FETs), a critical step towards their integration in real-life biosensing applications. A key requirement toward the fulfilment of SiNW FETs' promises in the bioanalytical field is their efficient integration within functional devices. Aiming to provide a comprehensive roadmap for the development of SiNW FET based sensing platforms, we critically review and discuss the key design and fabrication aspects relevant to their development and integration within complementary metal-oxide-semiconductor (CMOS) technology.
Collapse
|
65
|
Hlukhova H, Menger M, Offenhäusser A, Vitusevich S. Highly Sensitive Aptamer-Based Method for the Detection of Cardiac Biomolecules on Silicon Dioxide Surfaces. ACTA ACUST UNITED AC 2018. [DOI: 10.1557/adv.2018.332] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
|
66
|
Moulick RG, Panaitov G, Choi SE, Mayer D, Offenhäusser A. Patterning artificial lipid bilayer on nanostructured surfaces. Int J Nanomedicine 2018; 13:55-58. [PMID: 29593396 PMCID: PMC5863630 DOI: 10.2147/ijn.s125005] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
Artificial lipid bilayer on solid substrate plays an important role as an interface between nanotechnology and biology. In this study, grid structures were patterned on Au-Nb-glass substrate and artificial bilayer was prepared on these structures. The fluidity was checked using fluorescence recovery after photobleaching (FRAP), and neuronal adhesion was monitored on such structure using EphrinA5-tethered lipid bilayer. EphrinA5 is a ligand that binds to the Eph receptors of rat cortical neurons and influences cellular adhesion. Our result elucidated that influence of these nanopatterned protein-tethered lipid bilayer on cellular guidance and signaling can address many underlying mechanisms of cellular functioning and help us to understand and differentiate the signaling procedure in cancer and neurodegenerative diseases.
Collapse
|
67
|
Ghosh Moulick R, Panaitov G, Du L, Mayer D, Offenhäusser A. Neuronal adhesion and growth on nanopatterned EA5-POPC synthetic membranes. NANOSCALE 2018; 10:5295-5301. [PMID: 29498734 DOI: 10.1039/c7nr08520f] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Biomimetic membranes create opportunities for various applications, including the possibility of replacing interacting cells in a cell-cell contact. Here we have fractionated synthetic membranes using metal nano-grid structures where EphrinA5 (EA5), a neuronal adhesion promoter, was anchored via its Fc domain (immunoglobulin G (IgG)-domain). FRAP experiments were performed to check the confinement of the synthetic membrane within these nano-structures. Rat cortical primary neurons were cultured and live cell imaging techniques were used to monitor the neuronal interaction with these fractionated synthetic membranes. Computational imaging analysis of the corresponding images elucidated interesting details of the cellular behavior. The phenotypic cellular response on these nano-membrane fractions was found to be similar to that on non-fractionated synthetic membranes indicating that although the number of focal adhesion points was low (due to the reduced EA5 number) in the nano-sized membrane patches perhaps some other factors like metal grid boundaries might be playing a role in rendering the similarity.
Collapse
|
68
|
Belu A, Yilmaz M, Neumann E, Offenhäusser A, Demirel G, Mayer D. Asymmetric, nano-textured surfaces influence neuron viability and polarity. J Biomed Mater Res A 2018; 106:1634-1645. [PMID: 29427541 DOI: 10.1002/jbm.a.36363] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2017] [Revised: 01/09/2018] [Accepted: 02/01/2018] [Indexed: 02/06/2023]
Abstract
Three dimensional, nanostructured surfaces have attracted considerable attention in biomedical research since they have proven to represent a powerful platform to influence cell fate. In particular, nanorods and nanopillars possess great potential for the control of cell adhesion and differentiation, gene and biomolecule delivery, optical and electrical stimulation and recording, as well as cell patterning. Here, we investigate the influence of asymmetric poly(dichloro-p-xylene) (PPX) columnar films on the adhesion and maturation of cortical neurons. We show that nanostructured films with dense, inclined polymer columns can support viable primary neuronal culture. The cell-nanostructure interface is characterized showing a minimal cell penetration but strong adhesion on the surface. Moreover, we quantify the influence of the nano-textured surface on the neural development (soma size, neuritogenesis, and polarity) in comparison to a planar PPX sample. We demonstrate that the nanostructures facilitates an enhancement in neurite branching as well as elongation of axons and growth cones. Furthermore, we show for the first time that the asymmetric orientation of polymeric nanocolumns strongly influences the initiation direction of the axon formation. These results evidence that 3D nano-topographies can significantly change neural development and can be used to engineer axon elongation. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 106A: 1634-1645, 2018.
Collapse
|
69
|
Zhang P, Bousack H, Dai Y, Offenhäusser A, Mayer D. Shell-binary nanoparticle materials with variable electrical and electro-mechanical properties. NANOSCALE 2018; 10:992-1003. [PMID: 29265122 DOI: 10.1039/c7nr07912e] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/09/2023]
Abstract
Nanoparticle (NP) materials with the capability to adjust their electrical and electro-mechanical properties facilitate applications in strain sensing technology. Traditional NP materials based on single component NPs lack a systematic and effective means of tuning their electrical and electro-mechanical properties. Here, we report on a new type of shell-binary NP material fabricated by self-assembly with either homogeneous or heterogeneous arrangements of NPs. Variable electrical and electro-mechanical properties were obtained for both materials. We show that the electrical and electro-mechanical properties of these shell-binary NP materials are highly tunable and strongly affected by the NP species as well as their corresponding volume fraction ratio. The conductivity and the gauge factor of these shell-binary NP materials can be altered by about five and two orders of magnitude, respectively. These shell-binary NP materials with different arrangements of NPs also demonstrate different volume fraction dependent electro-mechanical properties. The shell-binary NP materials with a heterogeneous arrangement of NPs exhibit a peaking of the sensitivity at medium mixing ratios, which arises from the aggregation induced local strain enhancement. Studies on the electron transport regimes and micro-morphologies of these shell-binary NP materials revealed the different mechanisms accounting for the variable electrical and electro-mechanical properties. A model based on effective medium theory is used to describe the electrical and electro-mechanical properties of such shell-binary nanomaterials and shows an excellent match with experiment data. These shell-binary NP materials possess great potential applications in high-performance strain sensing technology due to their variable electrical and electro-mechanical properties.
Collapse
|
70
|
Schnitker J, Adly N, Seyock S, Bachmann B, Yakushenko A, Wolfrum B, Offenhäusser A. Rapid Prototyping of Ultralow-Cost, Inkjet-Printed Carbon Microelectrodes for Flexible Bioelectronic Devices. ACTA ACUST UNITED AC 2018. [DOI: 10.1002/adbi.201700136] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
71
|
Meeßen C, Graeve A, Offenhäusser A. Development of a 3D cell culture system based on a microfluidic platform. Front Cell Neurosci 2018. [DOI: 10.3389/conf.fncel.2018.38.00050] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
72
|
Hondrich T, Tihaa I, Lewen J, Offenhäusser A. Directing Neuronal Growth And Signal Propagation On MEA. Front Cell Neurosci 2018. [DOI: 10.3389/conf.fncel.2018.38.00056] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
73
|
Rincón Montes V, Srikantharajah K, Kireev D, Lange J, Offenhäusser A. From stiff silicon to compliant retinal and cortical multisite penetrating implants. Front Cell Neurosci 2018. [DOI: 10.3389/conf.fncel.2018.38.00072] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
74
|
Schöps V, Lenyk B, Huhn T, Boneberg J, Scheer E, Offenhäusser A, Mayer D. Facile, non-destructive characterization of 2d photonic crystals using UV-vis-spectroscopy. Phys Chem Chem Phys 2018; 20:4340-4346. [DOI: 10.1039/c7cp07498k] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
The quality of particle monolayers and size evolution of their particles during dry etching can be monitored by radiative losses of photonic modes into dielectric substrates.
Collapse
|
75
|
Huang X, Dong H, Qiu Y, Li B, Tao Q, Zhang Y, Krause HJ, Offenhäusser A, Xie X. Adaptive suppression of power line interference in ultra-low field magnetic resonance imaging in an unshielded environment. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2018; 286:52-59. [PMID: 29183004 DOI: 10.1016/j.jmr.2017.11.009] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/18/2017] [Revised: 11/16/2017] [Accepted: 11/17/2017] [Indexed: 06/07/2023]
Abstract
Power-line harmonic interference and fixed-frequency noise peaks may cause stripe-artifacts in ultra-low field (ULF) magnetic resonance imaging (MRI) in an unshielded environment and in a conductively shielded room. In this paper we describe an adaptive suppression method to eliminate these artifacts in MRI images. This technique utilizes spatial correlation of the interference from different positions, and is realized by subtracting the outputs of the reference channel(s) from those of the signal channel(s) using wavelet analysis and the least squares method. The adaptive suppression method is first implemented to remove the image artifacts in simulation. We then experimentally demonstrate the feasibility of this technique by adding three orthogonal superconducting quantum interference device (SQUID) magnetometers as reference channels to compensate the output of one 2nd-order gradiometer. The experimental results show great improvement in the imaging quality in both 1D and 2D MRI images at two common imaging frequencies, 1.3 kHz and 4.8 kHz. At both frequencies, the effective compensation bandwidth is as high as 2 kHz. Furthermore, we examine the longitudinal relaxation times of the same sample before and after compensation, and show that the MRI properties of the sample did not change after applying adaptive suppression. This technique can effectively increase the imaging bandwidth and be applied to ULF MRI detected by either SQUIDs or Faraday coil in both an unshielded environment and a conductively shielded room.
Collapse
|