51
|
Tan EK, Gibson JL, Gallagher A. A pregnant woman with raised bile acids – idiopathic adult ductopenia. Scott Med J 2009. [DOI: 10.1258/rsmsmj.54.2.58d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
52
|
Gallagher A, Gunther MM, Bruchhaus H. Population continuity, demic diffusion and Neolithic origins in central-southern Germany: the evidence from body proportions. HOMO-JOURNAL OF COMPARATIVE HUMAN BIOLOGY 2009; 60:95-126. [PMID: 19264304 DOI: 10.1016/j.jchb.2008.05.006] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/21/2008] [Accepted: 05/13/2008] [Indexed: 10/21/2022]
Abstract
The transition to agro-pastoralism in central Europe has been framed within a dichotomy of "regional continuity" versus exogenous "demic diffusion". While substantial genetic support exists for a model of demographic diffusion from an ancestral source in the Near East, archaeological data furnish weak support for the "wave of advance" model. Nevertheless, archaeological evidence attests the widespread introduction of an exogenous "package" comprising ceramics, cereals, pulses and domesticated animals to central Europe at 5600calBCE. Body proportions are under strong climatic selection and evince remarkable stability within regional lineages. As such, they offer a viable and robust alternative to cranio-facial data in assessing hypothesised continuity and replacement with the transition to agro-pastoralism in central Europe. Humero-clavicular, brachial and crural indices in a large sample (n=75) of Linienbandkeramik (LBK), Late Neolithic and Early Bronze Age specimens from the middle Elbe-Saale-Werra valley (MESV) were compared with Eurasian and African terminal Pleistocene, European Mesolithic and geographically disparate recent human specimens. Mesolithic Europeans display considerable variation in humero-clavicular and brachial indices yet none approach the extreme "hyper-polar" morphology of LBK humans from the MESV. In contrast, Late Neolithic and Early Bronze Age peoples display elongated brachial and crural indices reminiscent of terminal Pleistocene and "tropically adapted" recent humans. These marked morphological changes likely reflect exogenous immigration during the terminal Fourth millennium cal BC. Population expansion and diffusion is a function of increased mobility and settlement dispersal concomitant with significant technological and subsistence changes in later Neolithic societies during the late fourth millennium cal BCE.
Collapse
|
53
|
Gallagher A, Béland R, Vanassing P, Bringas M, Rodrı´guez Y, Ojeda A, Valdés Sosa P, Lassonde M. 214. N400 electrophysiological component dissociation between verbal and nonverbal processing: A source analysis study. Clin Neurophysiol 2008. [DOI: 10.1016/j.clinph.2008.04.230] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
54
|
Shultz S, Worzella T, Gallagher A, Shieh J, Goueli S, Hsiao K, Vidugiriene J. Miniaturized GPCR signaling studies in 1536-well format. J Biomol Tech 2008; 19:267-274. [PMID: 19137117 PMCID: PMC2567138] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
G protein-coupled receptors (GPCRs) are involved in various physiological processes, such as behavior changes, mood alteration, and regulation of immune-system activity. Thus, GPCRs are popular targets in drug screening, and a well-designed assay can speed up the discovery of novel drug candidates. The Promega cAMP-Glo Assay is a homogenous bioluminescent assay to monitor changes in intracellular cyclic adenosine monophosphate (cAMP) concentrations in response to the effect of an agonist, antagonist, or test compound on GPCRs. Together with the Labcyte Echo 555 acoustic liquid handler and the Deerac Fluidics Equator HTS reagent dispenser, this setup can screen compounds in 96-, 384-, and 1536-well formats for their effects on GPCRs. Here, we describe our optimization of the cAMP-Glo assay in 1536-well format, validate the pharmacology, and assess the assay robustness for HTS. We have successfully demonstrated the use of the assay in primary screening applications of known agonist and antagonist compounds, and confirmed the primary hits via secondary screening. Implementing a high-throughput miniaturized GPCR assay as demonstrated here allows effective screening for potential drug candidates.
Collapse
|
55
|
Lassonde M, Gallagher A, Bastien D, Vannasing P, Lesage F, Grova C, Lepore F, Beland R, Nguyen D. 34. Non-invasive pre-surgical investigation of a 10 year-old epileptic boy using simultaneous EEG–NIRS, MEG–EEG and fMRI–EEG. Clin Neurophysiol 2008. [DOI: 10.1016/j.clinph.2008.04.050] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
|
56
|
Liu MC, Isaacs C, Warren R, Cohen P, Wilkinson M, Ottaviano Y, Rao S, Zhang Y, Gallagher A, Shields PG. Circulating tumor cells (CTC): A reliable predictor of treatment efficacy in metastatic breast cancer (MBC). J Clin Oncol 2008. [DOI: 10.1200/jco.2008.26.15_suppl.11018] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
|
57
|
O'Connor U, Dowling A, Larkin A, Sheahan N, Gray L, Gallagher A, O'Reilly G, Kosunen A, Zdesar U, Malone JF. Development of training syllabi for radiation protection and quality assurance of dual-energy X-ray absorptiometry (DXA) systems. RADIATION PROTECTION DOSIMETRY 2008; 129:211-213. [PMID: 18397931 DOI: 10.1093/rpd/ncn088] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
The use of dual-energy X-ray absorptiometry (DXA) scanners for measuring bone mineral density (BMD) is on the increase. A single DXA scan is a relatively low-dose diagnostic X-ray examination; however, radiation protection (RP) issues should not be trivialised. One objective of the EU 6th Framework SENTINEL co-ordination action was to develop training syllabi in RP and quality assurance (QA) for BMD, and this study presents the results. An EU-wide survey was carried out which confirmed that there was a need for an accredited DXA RP training course in many EU states. There is also limited published guidance on acceptance testing/QA for DXA. Two training syllabi were developed: one on RP and one on QA of DXA systems. A training course was delivered in Ireland in 2006 by the Medical Physics & Bioengineering Department of St James's Hospital, Dublin. Following the training course, a PC-based training CD was developed and will be made available. A harmonised approach to training will promote consistent approaches to radiation safety across the EU.
Collapse
|
58
|
Gray L, Dowling A, Gallagher A, Gorman D, O'Connor U, Devine M, Larkin A, Walsh C, Malone JF. Acceptance testing and routine quality control in general radiography: mobile units and film/screen fixed systems. RADIATION PROTECTION DOSIMETRY 2008; 129:276-278. [PMID: 18326885 DOI: 10.1093/rpd/ncn033] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
This study presents the findings from acceptance testing and routine quality control (QC) of general radiographic X-ray equipment in Ireland during 2006 and early 2007, including mobile X-ray units and film/screen fixed systems. Acceptance testing and routine QC of the diagnostic X-ray imaging equipment are requirements of European and Irish legislation. One hundred general radiographic X-ray systems were tested within Ireland, 73% of them failed to meet the required QC guidelines, whereby one or more faults were identified. The majority of these failures were minor ones, requiring attention by the suppliers at the next routine service. Significant faults were only identified in seven systems. The suppliers were requested to investigate these issues as soon as possible and take the necessary corrective action. A review of the QC results highlights the need to perform comprehensive acceptance and routine testing of the systems.
Collapse
|
59
|
Gallagher A, Dowling A, Devine M, Bosmans H, Kaplanis P, Zdesar U, Vassileva J, Malone JF. European survey of dental X-ray equipment. RADIATION PROTECTION DOSIMETRY 2008; 129:284-287. [PMID: 18310096 DOI: 10.1093/rpd/ncn037] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
The implementation of an X-ray Quality Assurance (QA) program is a legal requirement in Europe as stipulated in the EU Council Directive 97/43/EURATOM (MED). A review of the literature has identified that European countries are performing some level of QA testing of their dental X-ray equipment, although the type and level to which testing is performed can differ. The European SENTINEL co-ordination action proposed to collate a survey of equipment data for both conventional and digital dental X-ray installations among the SENTINEL partners. The European QA results confirm that systems can be operated below tolerance, and in some cases significantly so, while still in clinical use. This can occur despite servicing of equipment. The results have emphasised the fact that there is a requirement for the medical physics/engineering professions to become more closely involved in the management of dental radiology equipment. This also includes their involvement in the development and delivery of appropriate training courses for dentists and suppliers of dental radiology equipment.
Collapse
|
60
|
Dowling A, Gallagher A, O'Connor U, Larkin A, Gorman D, Gray L, Malone J. Acceptance testing and QA of interventional cardiology systems. RADIATION PROTECTION DOSIMETRY 2008; 129:291-294. [PMID: 18283061 DOI: 10.1093/rpd/ncn042] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
Interventional cardiology (IC) is a rapidly growing field of medical specialisation. Such procedures are complex and may subject patients and operators to higher levels of risk than those encountered in general radiology. Acceptance testing and quality assurance (QA) of radiological equipment, including IC equipment, is a requirement of the EU Medical Exposures Directive (MED) (97/43/EURATOM). In addition, the MED identifies interventional radiology as an area of special concern. This study presents the results of a survey of 17 IC systems (including several flat panel detector systems) in Irish hospitals. The results of the survey indicate large differences in patient doses between manufacturers for equivalent levels of measured image quality. In addition, all systems were found to have failed one or more acceptance tests, with 60% of systems demonstrating significant problems at acceptance testing. The results of the survey demonstrate the importance of acceptance testing and QA in IC. The results also provide baseline data, which may be used in the development of future QA guidelines.
Collapse
|
61
|
Gallagher A, Dowling A, Renehan J, Clarke D, Malone JF. A training syllabus for radiation protection in dental radiology. RADIATION PROTECTION DOSIMETRY 2008; 129:219-221. [PMID: 18283059 DOI: 10.1093/rpd/ncn045] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
The EU Council Directive 97/43/EURATOM (MED) states that Member States shall ensure that adequate theoretical and practical training is provided for dental practitioners working with ionising radiation; this also includes the provision of continuing education and training programmes, post-qualification. The area of dental radiology is specifically mentioned in this legally binding document. The Department of Medical Physics and Bioengineering, St James's Hospital, Dublin, is particularly interested in the area of radiation protection training and routinely provides educational courses both at national and international levels. A recent review of their dental radiation protection course was undertaken in conjunction with a number of Principal Dental Surgeons within the Health Service Executive in Ireland. The revised course was delivered to over 200 dental staff members at two separate meetings during 2006. The response from attendees was very positive. It is proposed to extend this course to other dental professionals, working both in the Irish private and public health sectors in the future.
Collapse
|
62
|
O'Connor U, Dowling A, Gallagher A, Gorman D, Walsh C, Larkin A, Gray L, Devine M, Malone J. Acceptance testing of fluoroscopy systems used for interventional purposes. RADIATION PROTECTION DOSIMETRY 2008; 129:56-58. [PMID: 18285319 DOI: 10.1093/rpd/ncn041] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
This study presents the results of acceptance testing on 18 interventional fluoroscopy systems in Ireland. Acceptance testing and routine quality assurance (QA) of X-ray systems are the requirements of the EU Medical Exposures Directive (MED) and these requirements were subsequently implemented into Irish legislation. The MED states that special consideration should be given to the QA and dose assessment of high dose procedures such as interventional fluoroscopy. Owing to the advances in fluoroscopy technology, it has been found that comprehensive testing of interventional systems proves challenging in a busy hospital environment. A number of recurrent problems have been identified and are presented.
Collapse
|
63
|
Wilson KS, Freeland JML, Gallagher A, Cosby SL, Earle JAP, Alexander FE, Taylor GM, Jarrett RF. Measles virus and classical Hodgkin lymphoma: no evidence for a direct association. Int J Cancer 2007; 121:442-7. [PMID: 17390376 DOI: 10.1002/ijc.22629] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
A proportion of Hodgkin lymphoma (HL) cases are causally associated with the Epstein-Barr virus (EBV) but the aetiology of the remaining cases remains obscure. Over the last 3 decades several studies have found an association between HL and measles virus (MV) including a recent cohort study describing the detection of MV antigens in Hodgkin and Reed-Sternberg cells, the tumour cells in HL. In the present study we looked at the relationship between history of MV infection and risk of developing HL in a population-based, case/control study of HL. In addition we used immunohistochemistry and RT-PCR to look for direct evidence of MV in HL biopsies. There was no significant difference in the proportion of cases reporting previous measles compared to controls in the entire data set or when young adults were considered separately. Using a robust immunohistochemical assay for MV infection, we failed to find evidence of MV in biopsies from 97 cases of HL and RT-PCR studies similarly gave negative results. This study therefore provides no evidence that MV is directly involved in the development of HL. However, when age at first reported MV infection was investigated, significant differences emerged with children infected before school-age having higher risk, especially of EBV-ve HL, when compared with children infected at older ages; the interpretation of these latter results is unclear.
Collapse
|
64
|
Abstract
This article discusses ethical aspects of 'terminal sedation' in relation to end-of-life care. An examination of the literature reveals there are different definitions and explanations of terminal sedation. Some definitions appear compatible with the values of palliative care and nursing, whereas others could arguably be perceived as deserving of the term 'euthanasia in disguise'. The authors suggest that 'palliative sedation' is a more helpful term and argue that, when defined and understood appropriately, it is a defensible and ethical practice. Nurses should be clear about the purpose of their profession, honest about their intentions and respect the autonomy and dignity of the patients for whom they provide care. The doctrine or principle of 'double effect' has been put forward to support the practice of terminal sedation. The authors examine this doctrine and caution that nurses and other professions need to approach it critically in relation to terminal sedation. Vignettes are used to illustrate aspects of the discussion.
Collapse
|
65
|
Gallagher A, Butler TJ, Home PD. The effect of the optimal use of rapid-acting insulin analogues on insulin secretion in Type 2 diabetes. Diabetes Res Clin Pract 2007; 76:327-34. [PMID: 17092597 DOI: 10.1016/j.diabres.2006.09.001] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/21/2005] [Accepted: 09/04/2006] [Indexed: 11/22/2022]
Abstract
The abnormal glucose tolerance of Type 2 diabetes is characterized by post-prandial hyperglycaemia. We aimed to examine whether the restoration of a more physiological insulin profile using rapid-acting insulin analogues might, through effects on glucose toxicity, improve endogenous insulin secretion rate (ISR) and secondly improve markers of vascular risk. Eighteen people with insulin-treated Type 2 diabetes were recruited into a single centre, cross-over, open-labeled study. The order of pre-meal unmodified human insulin or insulin aspart was randomized: treatment periods lasted at least 8-12 weeks after which ISR was assessed by stepped low-dose glucose infusion and fasting markers of vascular risk measured. Glucose control was good (HbA(1c) 6.94+/-0.12 (+/-S.E.)% versus 7.07+/-0.13%, NS) with insulin aspart and human insulin. Mean post-prandial self-monitored blood glucose concentration was also good particularly with insulin aspart (7.5+/-0.41 mmol/l versus 8.19+/-0.34 mmol/l) but the difference did not reach statistical significance. Over 160 min ISR did not differ between insulin aspart and human insulin and there was also no change in various markers of vascular risk. In conclusion a meal-time+basal insulin regimen gave close to normal post-prandial blood glucose control with both the insulin aspart and human insulin regimens, such that no difference in ISR or markers of vascular risk could be demonstrated.
Collapse
|
66
|
Jarrett RF, Johnson D, Wilson KS, Gallagher A. Molecular methods for virus discovery. DEVELOPMENTS IN BIOLOGICALS 2006; 123:77-88; discussion 119-32. [PMID: 16566437] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/08/2023]
Abstract
The potential use of novel cell substrates from diverse animal species raises concerns about the transmission of hitherto unknown viral agents. Viruses that do not cause a cytopathic effect in cell culture may escape detection by conventional methods and molecular methods may therefore prove useful for screening for hitherto unknown viruses. This review describes currently used molecular methods for virus discovery, including degenerate PCR assays, representational difference analysis and rolling circle amplification, and summarises the advantages and disadvantages of each technique.
Collapse
|
67
|
Gallagher A, Home PD. The effect of improved post-prandial blood glucose control on post-prandial metabolism and markers of vascular risk in people with Type 2 diabetes. Diabetes Res Clin Pract 2005; 67:196-203. [PMID: 15713351 DOI: 10.1016/j.diabres.2004.07.010] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/21/2004] [Revised: 06/30/2004] [Accepted: 07/07/2004] [Indexed: 10/26/2022]
Abstract
A variety of abnormalities of metabolic, haemostatic and endothelial markers are associated with Type 2 diabetes. Evidence suggests that poor post-prandial blood glucose control may contribute to vascular risk. We aimed to examine whether the restoration of a more physiological insulin profile post-prandially would improve these abnormalities. Twenty-one patients with insulin-treated Type 2 diabetes were recruited into a single centre, crossover, double-blind study. Patients were randomized to unmodified human insulin or insulin aspart before main meals for 6-week study periods, both together with NPH insulin. At the end of each study period, pre-breakfast levels of markers of vascular risk were assessed and a test meal performed. There was no significant difference in HbA(1c) (7.04 +/- 0.13% (+/-S.E.) versus 7.15 +/- 0.11%, P = 0.060) with insulin aspart compared to human insulin at the end of each study period. The mean post-prandial blood glucose concentration at 90 min from self-monitored results was lower with insulin aspart than with human insulin (7.9 +/- 0.4 mmol/l versus 9.3 +/- 0.4 mmol/l, P = 0.011) as was study day post-prandial blood glucose at 90 min (8.4 +/- 0.5 mmol/l versus 9.2 +/- 0.6 mmol/l, P = 0.046). No significant differences were found in fasting lipid profile, apolipoproteins, fibrinogen, plasminogen activator inhibitor-1, E-selectin, or homocysteine between the two study periods. Insulin aspart resulted in improved post-prandial glycaemic control when compared to human insulin in Type 2 diabetic patients, but this was not associated with changes in markers of vascular risk.
Collapse
|
68
|
Dowling A, Gallagher A, Walsh C, Malone J. Equipment standards for interventional cardiology. RADIATION PROTECTION DOSIMETRY 2005; 117:79-86. [PMID: 16461508 DOI: 10.1093/rpd/nci732] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
Interventional radiology has seen rapid growth in cardiology and represents an alternative to hazardous surgery. Recently there has been a substantial growth in the number of procedures being performed and interventional cardiology (IC) procedures are the most common interventional procedures in Europe. Advances in imaging technology have facilitated the development of increasingly complex radiological IC equipment. Currently, the technology is developing at a rate ahead of supporting research, equipment standards and a regulatory framework. International standards play a key role in the design, manufacture and performance of radiological IC equipment. A survey of 12 IC systems (15 imaging chains) was conducted in Irish hospitals. The aim of the study was to assess the imbalance between rapidly advancing technology and existing standards and to propose recommendations for new IC equipment standards. The results demonstrate the need for definitive equipment requirements and standardisation in the design, manufacture, acceptance and maintenance of IC equipment.
Collapse
|
69
|
|
70
|
Curtis MA, Aduse Opoku J, Rangarajan M, Gallagher A, Sterne JAC, Reid CR, Evans HEA, Samuelsson B. Attenuation of the virulence of Porphyromonas gingivalis by using a specific synthetic Kgp protease inhibitor. Infect Immun 2002; 70:6968-75. [PMID: 12438376 PMCID: PMC132948 DOI: 10.1128/iai.70.12.6968-6975.2002] [Citation(s) in RCA: 58] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023] Open
Abstract
The Arg- and Lys-gingipains of Porphyromonas gingivalis are important virulence determinants in periodontal disease and may correspond to targets for immune- or drug-based treatment strategies. In this investigation we aimed to determine which of these enzymes represents the most promising molecular target for protease inhibitor-based therapy and to examine the effectiveness of the resultant compound in a murine virulence assay. Isogenic mutants with mutations in rgpA and rgpB (encoding Arg-gingipains) and in kgp (encoding Lys-gingipain) and a double mutant with mutations in rgpA and rgpB were prepared by using P. gingivalis W50. The virulence of these mutants indicated that Kgp is a promising drug target. Combinatorial chemistry was used to define the optimal substrate of Kgp, and from this information a specific slowly reversible inhibitor with a nanomolar K(i) was designed and synthesized. Growth of P. gingivalis W50 in the presence of this compound resembled the phenotype of the kgp isogenic mutant; in both instances bacterial colonies failed to form pigment on blood agar, and only poor growth was obtained in a defined medium containing albumin as the sole protein source. Furthermore, pretreatment of the wild-type organism with the Kgp inhibitor led to a significant reduction in virulence in the murine assay. These data emphasize the conclusion that Kgp is an important factor for both nutrition and virulence of P. gingivalis and that inhibitors of this enzyme may have therapeutic potential for the control of P. gingivalis infections. Protease inhibitors may be a potentially novel class of antimicrobial agents with relevance to the control of other bacterial pathogens.
Collapse
|
71
|
Abstract
Declarations of the importance of dignity in health care are commonplace in codes of practice and other mission statements, yet these documents never clarify dignity's meaning. Their vague aspirations are compared to comments from staff and patients about opportunities for and barriers against the promotion of dignity in elderly care institutions. These suggest that while nurses and health care assistants have an intuitive understanding of dignity, they either do not or cannot always bring it about in practice. Thus, despite stated intentions to promote dignity, it appears that the circumstances of at least some elderly care institutions cause patients to experience avoidable indignities. Such institutions are "undignifying institutions" because they fail to acknowledge dignity's basic components, focus excessively on quantifiable priorities, and have insufficient resources available to assure consistently dignifying care. As a partial solution, we argue that health workers should be taught to understand and specify the components of dignity, which will better prepare them to challenge undignifying practices and to recognise opportunities for dignity promotion.
Collapse
|
72
|
Boreham C, Twisk J, Neville C, Savage M, Murray L, Gallagher A. Associations between physical fitness and activity patterns during adolescence and cardiovascular risk factors in young adulthood: the Northern Ireland Young Hearts Project. Int J Sports Med 2002; 23 Suppl 1:S22-6. [PMID: 12012258 DOI: 10.1055/s-2002-28457] [Citation(s) in RCA: 69] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/16/2022]
Abstract
The aim of the present study was to examine relationships between cardiovascular disease (CVD) risk factor status in young adulthood (mean age = 22.5 yrs) and antecedent physical fitness and physical activity at ages 12 and 15 years. The data were obtained from the Young Hearts Project, a longitudinal observational study of CVD risk factors in a representative sample of young people from Northern Ireland. Physical fitness was measured by the 20-metre endurance shuttle run, and physical activity and sports participation by a self-report recall questionnaire. CVD risk factors examined included serum total cholesterol (TC) and HDL cholesterol concentrations, the TC:HDL ratio, systolic and diastolic blood pressure and body fatness (sum of four skinfolds). Linear regression analyses showed modest relationships between physical fitness in adolescence and both TC:HDL ratio and body fatness in young adulthood. No such relationships were apparent for adolescent physical activity. The promotion of physical fitness during adolescence may reduce exposure to other risk factors lasting into early adulthood.
Collapse
|
73
|
Keane S, Gallagher A, Ackroyd S, McShane MA, Edge JA. Cerebral venous thrombosis during diabetic ketoacidosis. Arch Dis Child 2002; 86:204-5. [PMID: 11861244 PMCID: PMC1719104 DOI: 10.1136/adc.86.3.204] [Citation(s) in RCA: 74] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Neurological deterioration during an episode of diabetic ketoacidosis is usually assumed to be caused by cerebral oedema. We present a case of cerebral venous sinus thrombosis presenting in a similar manner, also associated with severe iron deficiency anaemia. Computed tomography scanning provided the correct diagnosis and allowed institution of anticoagulation with improvement in neurological outcome. Neuroimaging should always be performed in suspected cerebral oedema associated with diabetic ketoacidosis in order to exclude other pathologies.
Collapse
|
74
|
Gallagher A, McHale J. After Bristol: the importance of informed consent. NURSING TIMES 2001; 97:32-4. [PMID: 11966284] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/24/2023]
|
75
|
Bohn JL, Nesbitt DJ, Gallagher A. Field enhancement in apertureless near-field scanning optical microscopy. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA. A, OPTICS, IMAGE SCIENCE, AND VISION 2001; 18:2998-3006. [PMID: 11760198 DOI: 10.1364/josaa.18.002998] [Citation(s) in RCA: 20] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
The near field of an apertureless near-field scanning optical microscopy probe is investigated with a multiple-multipole technique to obtain optical fields in the vicinity of a silicon probe tip and a glass substrate. The results demonstrate that electric field enhancements of >15 relative to the incident fields can be achieved near a silicon tip, implying intensity enhancements of several orders of magnitude. This enhancement arises both from the antenna effect of the elongated probe and from a proximity effect when the probe is near the substrate surface and its image dipoles play a role.
Collapse
|