51
|
Leclercq C, Walker S, Linde C, Clementy J, Marshall AJ, Ritter P, Djiane P, Mabo P, Levy T, Gadler F, Bailleul C, Daubert JC. Comparative effects of permanent biventricular and right-univentricular pacing in heart failure patients with chronic atrial fibrillation. Eur Heart J 2002; 23:1780-7. [PMID: 12419298 DOI: 10.1053/euhj.2002.3232] [Citation(s) in RCA: 332] [Impact Index Per Article: 15.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/11/2022] Open
Abstract
BACKGROUND One third of chronic heart failure patients have major intraventricular conduction and uncoordinated ventricular contraction. Non-controlled studies suggest that biventricular pacing may improve haemodynamics and well-being by reducing ventricular asynchrony. The aim of this trial was to assess the clinical efficacy and safety of this new therapy in patients with chronic atrial fibrillation. METHODS Fifty nine NYHA class III patients with left ventricular systolic dysfunction, chronic atrial fibrillation, slow ventricular rate necessitating permanent ventricular pacing, and a wide QRS complex (paced width >or=200 ms), were implanted with transvenous biventricular-VVIR pacemakers. This single-blind, randomized, controlled, crossover study compared the patients' parameters, as monitored during two 3-month treatment periods of conventional right-univentricular vs biventricular pacing. The primary end-point was the 6-min walked distance, secondary end-points were peak oxygen uptake, quality-of-life, hospitalizations, patients' preferred study period and mortality. RESULTS Because of a higher than expected drop-out rate (42%), only 37 patients completed both crossover phases. In the intention-to-treat analysis, we did not observe a significant difference. However, in the patients with effective therapy the mean walked distance increased by 9.3% with biventricular pacing (374+/-108 vs 342+/-103 m in univentricular;P =0.05). Peak oxygen uptake increased by 13% (P=0.04). Hospitalizations decreased by 70% and 85% of the patients preferred the biventricular pacing period (P<0.001). CONCLUSION As compared with conventional VVIR pacing, effective biventricular pacing seems to improve exercise tolerance in NYHA class III heart failure patients with chronic atrial fibrillation and wide paced-QRS complexes. Further randomized controlled studies are required to definitively validate this therapy in such patients.
Collapse
|
52
|
Braunschweig F, Linde C, Eriksson MJ, Hofman-Bang C, Rydén L. Continuous haemodynamic monitoring during withdrawal of diuretics in patients with congestive heart failure. Eur Heart J 2002; 23:59-69. [PMID: 11741363 DOI: 10.1053/euhj.2001.2690] [Citation(s) in RCA: 65] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/11/2022] Open
Abstract
AIMS Right heart pressure parameters can be recorded continuously with the help of an implanted haemodynamic monitor. The aim of this study was to investigate the usefulness of the device in adjusting diuretic medication in patients with chronic congestive heart failure, and to evaluate the response of right ventricular pressure to increased volume load induced by diuretic withdrawal. METHODS AND RESULTS Four patients with stable congestive heart failure were implanted with an implantable haemodynamic monitor. Furosemide, the only diuretic used, was reduced by 50% the first week, withdrawn completely for the second week and then reinstituted in the initial dose. Right ventricular systolic and diastolic pressure, pulse pressure, dP/dt, estimated diastolic pulmonary artery pressure and heart rate were sampled continuously. Patients were evaluated by body weight, NYHA class, serum creatinine, serum brain natriuretic peptide, the 6 min walk test, quality of life and echocardiography on days 0, 7, 14 and 21. We observed significant changes in right ventricular pressure parameters in parallel with clinical signs and symptoms of worsening heart failure, such as increased body weight, a shorter walking distance and impaired quality of life. Moreover elevated levels of brain natriuretic peptide and lower creatinine levels were observed. CONCLUSION Haemodynamic changes due to increased volume load can be detected with an implantable haemodynamic monitor. Such data provide useful information for tailoring an optimal diuretic dose in patients with congestive heart failure.
Collapse
|
53
|
Linde C, Markewitz A, Strandberg H, Larsson B, Binner L, Schüller H. Combipolar sensing in dual chamber pacing: is there still a need for bipolar leads in the atrium? Pacing Clin Electrophysiol 2001; 24:1664-71. [PMID: 11816637 DOI: 10.1046/j.1460-9592.2001.01664.x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
Bipolar leads have been shown to provide superior sensing conditions compared to unipolar leads as bipolar sensing is less susceptible to interference. However, the mechanical long-term integrity and longevity of bipolar leads is inferior to that of unipolar leads. A prospective randomized, multicenter study was performed to investigate a new atrial detection configuration called combipolar sensing. This new sensing concept is designed for the use of conventional unipolar leads in the atrium and the ventricle. While the atrial stimulation is unipolar, atrial sensing is accomplished in a bipolar way using the ventricular lead tip as the indifferent electrode. A modified dual chamber pacemaker provided with this sensing concept was implanted in 26 patients. At predischarge and at the 1- and 3-month follow-ups no significant differences in atrial sensing thresholds and P wave amplitudes were found between the unipolar and the combipolar sensing configuration at rest or during provocation. Myopotential inhibition could be demonstrated in 22 patients during unipolar sensing at sensitivity settings as "low" as 2 mV. In contrast, during combipolar sensing it could only be demonstrated in one patient once and only at the highest atrial sensitivity of 0.5 mV. Combipolar atrial sensing is feasible under normal conditions and during provocation. Myopotential interference is negligible. Thus, combipolar sensing offers comparable atrial sensing to bipolar without the disadvantages of a bipolar lead.
Collapse
|
54
|
Ito M, O'Day VL, Adler A, Linde C, Mynatt ED. Making a place for seniors on the Net. ACTA ACUST UNITED AC 2001. [DOI: 10.1145/504696.504699] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
55
|
|
56
|
Ector H, Rickards AF, Kappenberger L, Linde C, Vardas P, Oto A, Santini M, Sutton R. The World Survey of Cardiac Pacing and Implantable Cardioverter Defibrillators: calendar year 1997--Europe. Pacing Clin Electrophysiol 2001; 24:863-8. [PMID: 11388106 DOI: 10.1046/j.1460-9592.2001.00863.x] [Citation(s) in RCA: 41] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
The registry of the European Working Group on Cardiac Pacing (EWGCP) is based on the European Pacemaker Identification Card originally designed in July 1978. National registration centers collect the local data and send aggregated annual data to the EWGCP. For 1997, data were obtained from 2,887 hospitals in 20 European countries representing a population of 568 million. Across all participating countries, the median value for all implanted pacemakers was 378 per million population. For initial pacemaker implants, the median value was 290 per million population. Single chamber atrial pacing was important in Denmark, the Netherlands, Poland, Slovak Republic, Spain, and Sweden for the treatment of sick sinus syndrome. Dual chamber pacing accounted for < 50% of initial implants in only 5 of 14 countries for atrioventricular block, and in only 3 of 15 countries for sick sinus syndrome. In 7 of 15 countries, unipolar ventricular leads were used in > or = 50% of cases. In 6 of 14 countries, there was > 15% use of unipolar atrial leads. Nine of 13 countries frequently used atrial active-fixation leads. For the 1997 survey, ICD data were obtained from 16 countries. The total number of ICDs per million population was a median value of 14. Initial ICD implants per million population was 11. Only 3 of 16 countries implanted a total of 30 or more ICDs per million population. Pacing and ICD practices were dependent on the availability of medical and technical resources and influenced by economic constraints inherent in health care administration and insurance coverage patterns.
Collapse
|
57
|
Cazeau S, Leclercq C, Lavergne T, Walker S, Varma C, Linde C, Garrigue S, Kappenberger L, Haywood GA, Santini M, Bailleul C, Daubert JC. Effects of multisite biventricular pacing in patients with heart failure and intraventricular conduction delay. N Engl J Med 2001; 344:873-80. [PMID: 11259720 DOI: 10.1056/nejm200103223441202] [Citation(s) in RCA: 1808] [Impact Index Per Article: 78.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
BACKGROUND One third of patients with chronic heart failure have electrocardiographic evidence of a major intraventricular conduction delay, which may worsen left ventricular systolic dysfunction through asynchronous ventricular contraction. Uncontrolled studies suggest that multisite biventricular pacing improves hemodynamics and well-being by reducing ventricular asynchrony. We assessed the clinical efficacy and safety of this new therapy. METHODS Sixty-seven patients with severe heart failure (New York Heart Association class III) due to chronic left ventricular systolic dysfunction, with normal sinus rhythm and a duration of the QRS interval of more than 150 msec, received transvenous atriobiventricular pacemakers (with leads in one atrium and each ventricle). This single-blind, randomized, controlled crossover study compared the responses of the patients during two periods: a three-month period of inactive pacing (ventricular inhibited pacing at a basic rate of 40 bpm) and a three-month period of active (atriobiventricular) pacing. The primary end point was the distance walked in six minutes; the secondary end points were the quality of life as measured by questionnaire, peak oxygen consumption, hospitalizations related to heart failure, the patients' treatment preference (active vs. inactive pacing), and the mortality rate. RESULTS Nine patients were withdrawn from the study before randomization, and 10 failed to complete both study periods. Thus, 48 patients completed both phases of the study. The mean distance walked in six minutes was 22 percent greater with active pacing (399+/-100 m vs. 326+/-134 m, P<0.001), the quality-of-life score improved by 32 percent (P<0.001), peak oxygen uptake increased by 8 percent (P<0.03), hospitalizations were decreased by two thirds (P<0.05), and active pacing was preferred by 85 percent of the patients (P<0.001). CONCLUSIONS Although it is technically complex, atriobiventricular pacing significantly improves exercise tolerance and quality of life in patients with chronic heart failure and intraventricular conduction delay.
Collapse
|
58
|
Braunschweig F, Linde C, Eriksson M, Hofman-Bang C, Rydén L. Continuous hemodynamic monitoring during diuretic withdrawal in four patients with severe congestive heart failure. Europace 2001. [DOI: 10.1016/eupace/2.supplement_1.a92-a] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022] Open
|
59
|
Braunschweig F, Linde C, Gadler F, Rydén L. Biventricular pacing reduces hospital days in patients with severe congestive heart failure. Europace 2001. [DOI: 10.1016/eupace/2.supplement_1.a56-c] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
|
60
|
Abstract
The health care costs for heart failure are substantial. Studies indicate that hospital treatment constitutes 65-75% of these. The aim of this study was to assess total and heart failure related hospital days as well as safety and efficacy of biventricular pacing in 16 patients with severe heart failure and delayed intraventricular conduction (QRS duration >150 ms). They were implanted with a biventricular pacemaker and followed by NYHA class, 6-min walk test and quality of life for a mean of 291+/-76 days. Total number of hospital days and the need for hospitalisations were monitored. Thirteen responders improved by at least one functional class. After 6 months of pacing the 6-min walk test improved from 375+/-83 m to 437+/-73 m (P<0.001) and Minnesota Living with Heart Failure quality of life score from 41+/-19 to 24+/-17 (P<0.001) compared to baseline. The need for hospital care decreased significantly after biventricular pacing. The total number of hospital days in all patients was 253 the year before compared to 45 the year after biventricular pacing (P<0.01). For heart failure related hospital days the corresponding figures were 183 and 39 days, respectively (P<0.01). Biventricular pacing improved 13/16 patients with severe heart failure and wide QRS complexes in this open study. The improvement resulted in a reduced need for hospital care.
Collapse
|
61
|
Braunschweig F, Gadler F, Linde C, Kjellström B, Rydén L. [Biventricular pacing as a new therapeutic method in heart failure. An alternative for patients with intraventricular conduction disorders]. LAKARTIDNINGEN 2000; 97:4450-2, 4455-8. [PMID: 11068400] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/18/2023]
Abstract
Patients with severe heart failure often have interventricular conduction disturbances indicated by wide QRS complexes. The resulting uncoordinated contraction pattern leads to impaired systolic and diastolic function which might be overcome by a new technique, biventricular pacing. The first Swedish clinical trial is reported, an open study where 13 out of 16 patients improved in terms of functional class, walking test and quality of life after six months of treatment. The number of hospital days was markedly reduced after pacemaker implantation.
Collapse
|
62
|
|
63
|
|
64
|
|
65
|
Andreu D, Carreño C, Linde C, Boman HG, Andersson M. Identification of an anti-mycobacterial domain in NK-lysin and granulysin. Biochem J 1999; 344 Pt 3:845-9. [PMID: 10585872 PMCID: PMC1220707] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/14/2023]
Abstract
NK-lysin and granulysin are homologous cationic anti-bacterial peptides produced by pig and human cytolytic lymphocytes, respectively. The solution structure of NK-lysin comprises five amphipathic alpha-helices. To investigate the properties of a helix-loop-helix region postulated to be a membrane-docking part of NK-lysin, we synthesized 22- and 29-residue peptides reproducing this region for both NK-lysin and granulysin. CD spectroscopy of the synthetic peptides in a liposomal solution showed spectra typical of alpha-helical peptides. The peptides were active against Gram-positive and Gram-negative bacteria, with the two NK-lysin peptides showing higher anti-bacterial activities than the two from granulysin. One NK-lysin peptide was active against Pseudomonas aeruginosa and Staphylococcus aureus, two organisms against which NK-lysin is inactive. Granulysin peptides were inactive against these bacteria, in contrast with granulysin, which is known to be active against them. Both NK-lysin and all synthetic analogues killed Mycobacterium tuberculosis and K562 tumour cells, but did not display haemolytic activity. These results identify a potent anti-mycobacterial domain in NK-lysin and granulysin consisting of a 22-residue (helix 3) sequence plus a disulphide-constrained loop.
Collapse
|
66
|
Linde C, Smit WA. First Report of Rhizosis Caused by Ceratocystis radicicola on Date Palms in South Africa. PLANT DISEASE 1999; 83:880. [PMID: 30841064 DOI: 10.1094/pdis.1999.83.9.880b] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
During late summer (February to March) of 1997, a sudden loss of large date palms (Phoenix dactylifera L. 'Medjool') and adjacent suckers was observed in the Pofadder area of South Africa. The palms were planted in sandy soil, with flood irrigation from the adjacent Orange River. Initial symptoms included wilting of leaves, chlorosis of young leaves, and root necrosis. Ceratocystis radicicola (D.E. Bliss) C. Moreau (synamorph Ceratostomella radicicola; anamorph Chalara) was consistently isolated from necrotic roots and lower crown portions of diseased palms. Dark colored spores were observed in root sections. Pathogenicity studies were performed in a shadehouse on 5-year-old Medjool clones. Two experiments were conducted in which Medjool plants were inoculated with 2-week-old C. radicicola cultures grown on corn meal agar (CMA). In the first experiment, a 7-mm wound was made at the leaf base of 15 plants and inoculated with an agar plug of C. radicicola culture. The same number of control plants was inoculated with CMA. Wounds were sealed with Parafilm, and lesions were measured after 3 months. In the second experiment, conidial suspensions and pieces of mycelia from five C. radicicola cultures were harvested in 1.5 liters of water, and 100 ml of inoculum was added to each of 15 plants. Control plants (15 total) each received 100 ml of sterile water. Plants were examined after 3 months. In the first experiment, all leaves inoculated at the base with C. radicicola became necrotic at the point of inoculation, wilted rapidly, and died. In the second experiment, roots showed severe necrosis resembling rhizosis observed in the field. In each experiment, only three plants died, and C. radicicola was successfully isolated from all inoculated plants. No symptoms developed on control plants, and C. radicicola could not be isolated from them. Rhizosis of date palms caused by C. radicicola has been described in the United States (1) and differs from the disease of date palm stems, leaves, buds, and inflorescences caused by C. paradoxa (Dade) C. Moreau. This is the first report of rhizosis on date palms in South Africa. Reference: (1) D. E. Bliss. Phytopathology 31:1123, 1941.
Collapse
|
67
|
Gadler F, Linde C, Daubert C, McKenna W, Meisel E, Aliot E, Chojnowska L, Guize L, Gras D, Jeanrenaud X, Kappenberger L. Significant improvement of quality of life following atrioventricular synchronous pacing in patients with hypertrophic obstructive cardiomyopathy. Data from 1 year of follow-up. PIC study group. Pacing In Cardiomyopathy. Eur Heart J 1999; 20:1044-50. [PMID: 10381856 DOI: 10.1053/euhj.1998.1331] [Citation(s) in RCA: 43] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/11/2022] Open
Abstract
AIMS Atrioventricular synchronous pacing exerts beneficial effects, including reduction of left ventricular outflow tract gradients, in patients with hypertrophic obstructive cardiomyopathy. The Pacing in Cardiomyopathy study was initiated to explore the effects of pacing in a double-blind randomized crossover fashion. The aims were to ascertain the beneficial effects of pacing in a controlled study and to rule out a placebo effect by pacing. This paper deals with the outcome of pacing on quality of life during 1 year of follow-up. METHODS Quality of life was evaluated with the Karolinska questionnaire, validated for patients paced for bradyarrhythmias and ischaemic heart disease. Drug-refractory patients with hypertrophic obstructive cardiomyopathy were recruited for the study and after a temporary pacing procedure implanted with permanent pacemakers. Patients were randomized to two study arms defining the sequence of pacemaker programming. In one arm the pacemaker was inactive, in the other active. After 3 months the pacemaker was reprogrammed to the alternate mode and a further 3 months followed. After this period subsequent pacemaker programming corresponded to the mode preferred by the patient. A last assessment was made 1 year after baseline examinations. RESULTS Eighty patients completed the first crossover period and 75 completed the full 1 year of follow-up. Active pacing induced significant quality of life improvements, in the order of 9-44%, regardless of programming sequence. Discontinuation of pacing after a first active period resulted in the return of symptoms. Fourteen patients requested early reprogramming after having been programmed to inactive pacing after a first period of active pacing. Seventy-six patients preferred active pacing after the crossover period. A further 6 months of pacing induced progressive improvement in symptoms already favourably influenced. CONCLUSION Atrioventricular synchronous pacing has a profound beneficial effect on most domains of quality of life in patients with hypertrophic obstructive cardiomyopathy refractory to drug treatment.
Collapse
|
68
|
Thomsen PE, Huikuri H, Køber L, Linde C, Koistinen J, Ohm OJ, Rokkedal J, Torp-Pedersen C. Lessons from the Nordic ICD pilot study. Lancet 1999; 353:2130. [PMID: 10382706 DOI: 10.1016/s0140-6736(98)04999-x] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
69
|
Kappenberger LJ, Linde C, Jeanrenaud X, Daubert C, McKenna W, Meisel E, Sadoul N, Chojnowska L, Guize L, Gras D, Aebischer N, Gadler F, Rydén L. Clinical progress after randomized on/off pacemaker treatment for hypertrophic obstructive cardiomyopathy. Pacing in Cardiomyopathy (PIC) Study Group. Europace 1999; 1:77-84. [PMID: 11233189 DOI: 10.1053/eupc.1998.0024] [Citation(s) in RCA: 38] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022] Open
Abstract
BACKGROUND The therapeutic options for hypertrophic obstructive cardiomyopathy (HOCM) classically include medical treatment with beta-blockers and calcium antagonists or myectomy-myotomy as a surgical possibility for refractory cases. The observation that pacemaker activation of the heart in HOCM reduces the subaortic gradient is well known but less well investigated. METHODS Eighty-three patients (33 female and 50 male) mean age 53 (18-82) years, with symptoms refractory to drug treatment and a resting gradient above 30 mmHg, who responded favourably to temporary pacing, were included in this prospective study and had a pacemaker (DDD) implanted. After an initial double-blind crossover phase of 6 months, patients were reinvestigated at 12 months and followed for a mean of 36 months. RESULTS As observed during a screening investigation, the obstruction was significantly reduced from 72 +/- 35 mmHg to 29 +/- 24 mmHg (P < 0.01) when the pacemaker was on, while no major effect was seen during the sham phase. The effect was persistent at 1 year with a remaining resting gradient of 28 +/- 24 mmHg. In parallel, we documented an improvement in functional capacity, according to the NYHA classification and by quality of life analysis, and a significant improvement in dyspnoea and angina. Exercise on treadmill improved only in patients with reduced initial tolerance (< 8 min). During the mean follow-up of 36 months, 65 patients remained on pacing alone, with eight patients having additional AV-node ablation and five patients finally having surgery. CONCLUSION This controlled multicentre study shows that pacemaker treatment is an option for HOCM patients; it is inoffensive and does not exclude alternative methods, but satisfies 79% of patients beyond 3 years.
Collapse
|
70
|
Linde C. [It is not easy to examine the causes of fainting. Vasovagal syncope is mostly not dangerous, cardiac syncope is potentially life-threatening]. LAKARTIDNINGEN 1999; 96:1294-9. [PMID: 10194907] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/11/2023]
Abstract
Of the approximately 30 per cent of the population who are afflicted with syncope at some time of life, 30 per cent will relapse. Despite extensive investigation, no specific cause is identified in about one third of cases. Although some episodes of syncope, e.g. cardiovascular syncope, are benign and self-limiting, others such as mechanical cardiac syncope and arrhythmogenic syncope are associated with considerable mortality. The article consists in a review of available data on differential diagnostic evaluation and treatment with special emphasis on case history.
Collapse
|
71
|
Linde C, Gadler F, Kappenberger L, Rydén L. Placebo effect of pacemaker implantation in obstructive hypertrophic cardiomyopathy. PIC Study Group. Pacing In Cardiomyopathy. Am J Cardiol 1999; 83:903-7. [PMID: 10190407 DOI: 10.1016/s0002-9149(98)01065-0] [Citation(s) in RCA: 119] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
This study evaluated a possible placebo effect by pacemaker implantation. The study design was a 3-month multicenter, double-blind, randomized cross-over study to compare the effects of atrioventricular (AV) synchronous pacing with an optimal AV delay to inactive pacing in patients with obstructive hypertrophic cardiomyopathy (HC). Quality of life and left ventricular (LV) outflow tract obstruction were evaluated after the first study period in 40 patients assigned to inactive pacing. Data were compared with the corresponding results among the 41 subjects assigned to a first study period of active pacing. During inactive pacing, there was a significant improvement in perceived chest pain, dyspnea, and palpitations. Moreover, LV outflow tract gradient decreased from 71 +/- 32 mm Hg to 52 +/- 34 mm Hg (p = 0.04). In patients assigned to active pacing the reduction of the gradient was significantly more pronounced (70 +/- 24 mm Hg to 33 +/- 27 mm Hg; p <0.0001). The difference in gradient reduction between the groups was highly significant (p <0.00001). In the group assigned to active pacing there was also significant improvement in perceived symptoms as well as in alertness, the ability to be self-autonomous, and strenuous physical exercise. The improvements in the latter were significantly greater in those paced actively compared with patients paced inactively, whereas the changes in perceived symptoms did not differ between groups. In conclusion, pacemaker implantation had a placebo effect on objective and subjective parameters in this group of patients with obstructive HC.
Collapse
|
72
|
Gadler F, Linde C, Rydén L. Rapid return of left ventricular outflow tract obstruction and symptoms following cessation of long-term atrioventricular synchronous pacing for obstructive hypertrophic cardiomyopathy. Am J Cardiol 1999; 83:553-7. [PMID: 10073860 DOI: 10.1016/s0002-9149(98)00912-6] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Abstract
Atrioventricular (AV) synchronous pacing reduces left ventricular (LV) outflow tract obstruction and symptoms in patients with obstructive hypertrophic cardiomyopathy (HC). The duration of gradient reduction, if pacing is discontinued for a prolonged period of time, is unknown. This question is addressed in the present randomized double-blind crossover study comparing continued with inactivated pacing. Ten patients, successfully paced for > or = 6 months, were randomized to continue pacing or to have their pacemakers inactivated after baseline examinations, including echo-Doppler imaging, exercise testing, and a quality-of-life questionnaire. When entering the study, the patients were in New York Heart Association functional classes I to II. After pacemaker programming, examinations were repeated at 1, 4, and 12 weeks. At the 12-week follow-up the alternate pacing mode was programmed, and the patient entered the second study arm. Premature pacemaker pacing occurred if severe clinical deterioration or a significant increase of the LV outflow tract obstruction were evident. Three patients started in the inactive mode and 7 patients in the active mode. All patients who started with the pacemaker inactivated required early reprogramming due to return of symptoms after 7, 10, and 13 days, respectively. All 7 patients who started in the active pacing mode completed the first period; however, after reprogramming to the inactive mode they required early activation after 1 to 20 days due to reappearance of intolerable subjective symptoms. The LV outflow tract gradient increased significantly after inactivation of pacing in all patients (22 +/- 21 mm Hg to 47 +/- 21 mm Hg). Thus, AV synchronous pacing effectively relieves symptoms and reduces the LV outflow tract gradient in patients with obstructive HC. This improvement, which is rapidly established with the initiation of cardiac pacing, is not persistent after cessation of pacing. Reinitialization of pacing promptly reduces the LV outflow tract obstruction and relieves symptoms to a preexisting extent.
Collapse
|
73
|
Gadler F, Linde C, Darpö B. Modification of atrioventricular conduction as adjunct therapy for pacemaker-treated patients with hypertrophic obstructive cardiomyopathy. Eur Heart J 1998; 19:132-8. [PMID: 9503186 DOI: 10.1053/euhj.1997.0561] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
Abstract
AIMS Atrioventricular synchronous pacing offers symptomatic relief for patients with drug-refractory hypertrophic obstructive cardiomyopathy. Successful treatment requires complete right ventricular apical pre-excitation. Enhanced atrioventricular conduction renders this difficult in some patients. The aim of this study was to evaluate whether selective prolongation of atrioventricular conduction is a useful tool for optimization of treatment in patients with hypertrophic obstructive cardiomyopathy primarily refractory to cardiac pacing. METHODS Six patients refractory to pacemaker treatment for 3-19 months underwent radiofrequency modification of atrioventricular conduction. Patients were followed with echo-Doppler, exercise testing and clinical evaluation for 6-12 months after modification. RESULTS Intrinsic PQ time was significantly prolonged from 175 +/- 18 ms to 253 +/- 22 ms; however, one patient exhibited complete block at one month follow-up. Left ventricular outflow tract obstruction decreased from 74 +/- 17 mmHg to 28 +/- 27 mmHg at the 6-month follow-up. Symptomatic improvement of at least one functional class was recorded in all patients; exercise tolerance remained unchanged, however, less angina and dyspnoea were reported in everyday life. CONCLUSION Radiofrequency modification of atrioventricular conduction, with persistent prolongation of the PQ interval, enhances the effects of pacing in patients with hypertrophic obstructive cardiomyopathy. This treatment enhances left ventricular outflow tract gradient reduction and improves symptoms.
Collapse
|
74
|
Darpö B, Walfridsson H, Aunes M, Bergfeldt L, Edvardsson N, Linde C, Lurje L, van der Linden M, Rosenqvist M. Incidence of sudden death after radiofrequency ablation of the atrioventricular junction for atrial fibrillation. Am J Cardiol 1997; 80:1174-7. [PMID: 9359545 DOI: 10.1016/s0002-9149(97)00635-8] [Citation(s) in RCA: 47] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
This study assesses the incidence of sudden death and classifies the causes of death following radiofrequency ablation of the atrioventricular (AV) junction. We studied 220 patients with paroxysmal (n = 105) or chronic (n = 115) atrial fibrillation (AF) and a mean age of 64 +/- 12 years. These patients were followed 31 +/- 15 months after radiofrequency ablation of the AV junction and pacemaker implantation. In 86 patients, structural heart disease was identified before the procedure. All patients were traced via the Swedish National Civic Registry and Cause of Death Registry. The cause-of-death was classified according to data from death certificates, autopsy protocols, and medical records. Thirty-one patients (mean age 69 +/- 11 years, 16 men) died 15 +/- 15 months (range 0.2 to 60) after the procedure. There were 6 sudden unexplained deaths, 14 cardiovascular deaths, and 11 deaths from noncardiovascular causes. Eleven patients, all with structural heart disease, died suddenly out of hospital 16 +/- 16 months (range 0.2 to 42) after the procedure. In 6 of these there was no obvious cause of death. Three of these 6 patients underwent autopsy, which showed extensive coronary artery disease (n = 1), severe heart failure (n = 1) and cardiac hypertrophy and dilation (n = 1). The remaining 3 all had depressed left ventricular systolic function and a history of congestive heart failure. Five of the patients who died suddenly from cardiovascular causes had autopsies that revealed acute myocardial infarction (n = 4) and massive pulmonary embolism (n = 1).
Collapse
|
75
|
Linde C, Löffler C, Kessler C, Quast U. Interaction between thiol-modifying agents and P1075, a K(ATP) channel opener, in rat isolated aorta. NAUNYN-SCHMIEDEBERG'S ARCHIVES OF PHARMACOLOGY 1997; 356:467-74. [PMID: 9349633 DOI: 10.1007/pl00005078] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
In vascular smooth muscle, openers of ATP-dependent potassium channels (K(ATP) channels), such as P1075 (N-cyano-N'-(1,1-dimethylpropyl)-N"-3-pyridylguanidine), produce relaxation. In this study we have investigated the effects of thiol-modifying agents on the binding of P1075 and on the 86Rb+ efflux stimulating and vasorelaxant effects of the opener in rat aortic rings. The increase in 86Rb+ efflux induced by P1075 was taken as a qualitative measure of K+ channel opening. The hydrophilic SH-group-oxidizing substance, thimerosal (1 to 100 microM), abolished specific binding of [3H]-P1075 with an IC50 value of 7.6+/-1.2 microM; at 30 microM, the half time for inhibition was 38 min. Two other thioloxidizing agents, PMB (4-hydroxy-mercuribenzoic acid) and DTBNP (2,2'-dithio-bis(5-nitropyridine)), inhibited binding up to 86% and 44%, respectively. The disulphide bond reducing substance, DTT (1,4-dithiothreitol, 0.1 to 1 mM), reduced [3H]-P1075 binding by up to 20% and partially reversed the inhibitory effect of thimerosal. In 86Rb+ efflux experiments, thimerosal (3 to 100 microM) concentration-dependently increased basal efflux but inhibited P1075-stimulated tracer efflux with an IC50 value of 7+/-1 microM. The inhibitory effect occurred with a half-time of approximately 8 min and was essentially reversed by DTT. In rings precontracted with noradrenaline, thimerosal inhibited the vasorelaxant effect in a noncompetitive manner, shifting the concentration-relaxation curves to the right and reducing maximum relaxation. The data show that oxidation of thiol groups interferes with the binding of the K(ATP) channel opener, P1075; concomitantly, the 86Rb+ efflux stimulating and the vasorelaxant effects are inhibited. Reduction of disulphide bonds by DTT has only minor effects on the action of P1075. Collectively, the results suggest that intact thiol groups are essential for the functioning of the K(ATP) channel in rat aorta. The different kinetics governing the inhibition of opener binding and of opener-stimulated 86Rb+ efflux suggest that the SH-groups involved in the two processes differ in their accessibility to thimerosal and/or in their reactivity.
Collapse
|