51
|
Tashkin DP, Rennard S, Taylor Hays J, Lawrence D, Marton JP, Lee TC. Lung function and respiratory symptoms in a 1-year randomized smoking cessation trial of varenicline in COPD patients. Respir Med 2011; 105:1682-90. [PMID: 21621992 DOI: 10.1016/j.rmed.2011.04.016] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/27/2011] [Accepted: 04/28/2011] [Indexed: 10/18/2022]
Abstract
UNLABELLED There are few data concerning changes in lung function and respiratory symptoms in smokers with chronic obstructive pulmonary disease (COPD) weeks to months after quitting smoking. We examined serial changes in spirometry and Clinical COPD Questionnaire (CCQ) scores (measuring respiratory symptoms and health-related quality of life) in COPD participants by smoking status during a smoking cessation trial. In this randomized, double-blind trial, smokers with mild-to-moderate COPD were treated with varenicline 1 mg b.i.d. or placebo for 12 weeks and followed to Week 52. Primary endpoints of abstinence were previously reported. Secondary endpoints were mean changes from baseline in post-bronchodilator forced expired volume in 1 s (FEV(1)) and CCQ scores. Change from baseline in post-bronchodilator FEV(1) was significantly improved in continuous abstainers (121.8 mL) vs. continuous smokers (37.9 mL) at Week 12 (P = 0.0069), but not at Weeks 24 or 52. Mean change from baseline at Week 12 in CCQ Total Score was significantly better in continuous abstainers (-1.04) vs. continuous smokers (-0.53; P < 0.0001): this improvement was sustained at Weeks 24 and 52. In a 1-year cessation trial of smokers with COPD, continuous abstinence compared with continuous smoking significantly improved post-bronchodilator FEV(1) at Week 12 (although the difference narrowed subsequently) and CCQ Total Scores at Week 12, with sustained improvement thereafter. ( TRIAL REGISTRY http://www.clinicaltrials.gov; trial identifier: NCT00285012).
Collapse
|
52
|
Larin I, McNulty D, Clinton E, Ambrozewicz P, Lawrence D, Nakagawa I, Prok Y, Teymurazyan A, Ahmidouch A, Asratyan A, Baker K, Benton L, Bernstein AM, Burkert V, Cole P, Collins P, Dale D, Danagoulian S, Davidenko G, Demirchyan R, Deur A, Dolgolenko A, Dzyubenko G, Ent R, Evdokimov A, Feng J, Gabrielyan M, Gan L, Gasparian A, Gevorkyan S, Glamazdin A, Goryachev V, Gyurjyan V, Hardy K, He J, Ito M, Jiang L, Kashy D, Khandaker M, Kingsberry P, Kolarkar A, Konchatnyi M, Korchin A, Korsch W, Kowalski S, Kubantsev M, Kubarovsky V, Li X, Martel P, Matveev V, Mecking B, Milbrath B, Minehart R, Miskimen R, Mochalov V, Mtingwa S, Overby S, Pasyuk E, Payen M, Pedroni R, Ritchie B, Rodrigues TE, Salgado C, Shahinyan A, Sitnikov A, Sober D, Stepanyan S, Stephens W, Underwood J, Vasiliev A, Vishnyakov V, Wood M, Zhou S. New Measurement of the π0 radiative decay width. PHYSICAL REVIEW LETTERS 2011; 106:162303. [PMID: 21599360 DOI: 10.1103/physrevlett.106.162303] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/12/2010] [Indexed: 05/30/2023]
Abstract
High precision measurements of the differential cross sections for π0 photoproduction at forward angles for two nuclei, 12C and 208Pb, have been performed for incident photon energies of 4.9-5.5 GeV to extract the π0→γγ decay width. The experiment was done at Jefferson Lab using the Hall B photon tagger and a high-resolution multichannel calorimeter. The π0→γγ decay width was extracted by fitting the measured cross sections using recently updated theoretical models for the process. The resulting value for the decay width is Γ(π0→γγ)=7.82±0.14(stat)±0.17(syst) eV. With the 2.8% total uncertainty, this result is a factor of 2.5 more precise than the current Particle Data Group average of this fundamental quantity, and it is consistent with current theoretical predictions.
Collapse
|
53
|
Leape L, Berwick D, Clancy C, Conway J, Gluck P, Guest J, Lawrence D, Morath J, O'Leary D, O'Neill P, Pinakiewicz D, Isaac T. Transforming healthcare: a safety imperative. Qual Saf Health Care 2011; 18:424-8. [PMID: 19955451 DOI: 10.1136/qshc.2009.036954] [Citation(s) in RCA: 259] [Impact Index Per Article: 19.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
Ten years ago, the Institute of Medicine reported alarming data on the scope and impact of medical errors in the US and called for national efforts to address this problem. While efforts to improve patient safety have proliferated during the past decade, progress toward improvement has been frustratingly slow. Some of this lack of progress may be attributable to the persistence of a medical ethos, institutionalized in the hierarchical structure of academic medicine and healthcare organizations, that discourages teamwork and transparency and undermines the establishment of clear systems of accountability for safe care. The Lucian Leape Institute, established by the US National Patient Safety Foundation to provide vision and strategic direction for the patient safety work, has identified five concepts as fundamental to the endeavor of achieving meaningful improvement in healthcare system safety. These five concepts are transparency, care integration, patient/consumer engagement, restoration of joy and meaning in work, and medical education reform. This paper introduces the five concepts and illustrates the meaning and implications of each as a component of a vision for healthcare safety improvement. In future roundtable sessions, the Institute will further elaborate on the meaning of each concept, identify the challenges to implementation, and issue recommendations for policy makers, organizations, and healthcare professionals.
Collapse
|
54
|
Diaz A, Di Salvo C, Lawrence D, Hayward M. Left atrial and right ventricular myxoma: an uncommon presentation of a rare tumour. Interact Cardiovasc Thorac Surg 2011; 12:622-3. [DOI: 10.1510/icvts.2010.255661] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
|
55
|
Pickup G, Jin M, Olden P, Mackay E, Todd A, Ford J, Lawrence D, Monaghan A, Naylor M, Haszeldine R, Smith M. Geological storage of CO2 : Site appraisal and modelling. ACTA ACUST UNITED AC 2011. [DOI: 10.1016/j.egypro.2011.02.440] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
56
|
Marks DJB, Fisk M, Koo CY, Lee SF, Lawrence D, Miller RF, Zumla A. P67 Outcomes from surgical management of pleural infection: 12-year experience from a tertiary cardiothoracic centre. Thorax 2010. [DOI: 10.1136/thx.2010.150979.18] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
|
57
|
Naqvi J, Navani N, Saeed S, Shastry M, Groves A, Shaw P, Lawrence D, Kolvekar S, Hayward M, Janes S. P222 A retrospective study of disease recurrence post thoracotomy for non-small cell lung cancer. Thorax 2010. [DOI: 10.1136/thx.2010.151068.23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
|
58
|
Bull M, Lawrence D. A Pilot Study: Postpartum Mothers' Perception of the Information Received in the Hospital and Its Usefulness During the First Weeks at Home. J Community Health Nurs 2010; 1:111-24. [PMID: 6565741 DOI: 10.1207/s15327655jchn0102_5] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/31/2022]
|
59
|
Magnussen H, Iqbal A, Kramer B, Higgins M, Lawrence D. Dosisselektion für Indacaterol: Anwendung eines Adaptive-Seamless-Designs in einer klinischen Studie zur COPD. Pneumologie 2010. [DOI: 10.1055/s-0030-1251403] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
60
|
Heise T, Mathieu C, Hey-Hadavi J, Strack T, Lawrence D. Glycemic control with preprandial versus basal insulin in patients with type 2 diabetes mellitus poorly controlled by oral antidiabetes agents. Diabetes Technol Ther 2010; 12:135-41. [PMID: 20105043 DOI: 10.1089/dia.2009.0105] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
OBJECTIVE This study was designed to compare glycemic control (glycated hemoglobin [A1C] level) with either once-daily basal insulin (BI) (insulin glargine) or preprandial insulin (PPI) (Exubera) [insulin human (recombinant DNA origin)] inhalation powder, Pfizer Inc., New York, NY) in patients with type 2 diabetes mellitus (T2DM) poorly controlled on at least two oral antidiabetes agents (OADs). METHODS This was a 26-week, open-label, parallel-group, randomized study where 257 patients (mean A1C 8.6%) on OAD treatment for > or = 3 months were treated with either BI (n = 122) or PPI (n = 135). Based on self-monitored blood glucose levels, PPI dose was adjusted before each major meal, whereas BI dose was titrated in the morning or before bedtime. Prestudy OADs were continued, but doses could be modified. RESULTS At 26 weeks, change from baseline in A1C was greater with PPI (-1.7 vs. -1.4%, P = 0.0389). Numerically, more patients achieved A1C <6.5% (28% vs. 19%) and A1C <7.0% (63% vs. 55%) with PPI compared with BI. PPI had lower postmeal glucose increments, but higher prebreakfast glucose and weight gain (1.1kg), than BI. Mild or moderate hypoglycemic events were more frequent with PPI (6.2 vs. 2.9 events/months), but nocturnal hypoglycemic events were less frequent (22% vs. 30%). CONCLUSIONS PPI improved postprandial glucose and A1C levels significantly more than BI. More patients achieved A1C targets with PPI, at the expense of more hypoglycemia and body weight gain. These results illustrate the potential benefits and detriments of prandial insulin supplementation in patients with T2DM poorly controlled on OADs alone.
Collapse
|
61
|
Godfray HCJ, Beddington JR, Crute IR, Haddad L, Lawrence D, Muir JF, Pretty J, Robinson S, Thomas SM, Toulmin C. Food Security: The Challenge of Feeding 9 Billion People. Science 2010; 327:812-8. [DOI: 10.1126/science.1185383] [Citation(s) in RCA: 6548] [Impact Index Per Article: 467.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/02/2022]
|
62
|
Fowler J, Solanki C, Guenther I, Barber R, Miller F, Bobrow L, Ravichandran D, Lawrence D, Ballinger J, Douglas-Jones A, Purushotham A, Peters A. A pilot study of dual-isotope lymphoscintigraphy for breast sentinel node biopsy comparing intradermal and intraparenchymal injection. Eur J Surg Oncol 2009; 35:1041-7. [DOI: 10.1016/j.ejso.2009.02.018] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2008] [Revised: 02/23/2009] [Accepted: 02/24/2009] [Indexed: 11/29/2022] Open
|
63
|
D'Andrea M, Lawrence D, Nagele R, Wang C, Damiano B. PCNA indexing as a preclinical immunohistochemical biomarker for testicular toxicity. Biotech Histochem 2009; 83:211-20. [DOI: 10.1080/10520290802521804] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022] Open
|
64
|
Chapman M, Lawrence D, Sims C, Bennett M. Induction of labour by prostaglandin pessaries or oxytocin infusion after spontaneous rupture of membranes. J OBSTET GYNAECOL 2009. [DOI: 10.3109/01443618409075712] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
65
|
Venugopal V, Hausenloy DJ, Ludman A, Di Salvo C, Kolvekar S, Yap J, Lawrence D, Bognolo J, Yellon DM. Remote ischaemic preconditioning reduces myocardial injury in patients undergoing cardiac surgery with cold-blood cardioplegia: a randomised controlled trial. Heart 2009; 95:1567-71. [PMID: 19508973 DOI: 10.1136/hrt.2008.155770] [Citation(s) in RCA: 184] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/19/2022] Open
Abstract
BACKGROUND Remote ischaemic preconditioning (RIPC) induced by brief ischaemia and reperfusion of the arm reduces myocardial injury in coronary artery bypass (CABG) surgery patients receiving predominantly cross-clamp fibrillation for myocardial protection. However, cold-blood cardioplegia is the more commonly used method world wide. OBJECTIVE To assess whether RIPC is cardioprotective in CABG patients receiving cold-blood cardioplegia. DESIGN Single-centre, single-blinded, randomised controlled trial. SETTING Tertiary referral hospital in London. PATIENTS Adults patients (18-80 years) undergoing elective CABG surgery with or without concomitant aortic valve surgery with cold-blood cardioplegia. Patients with diabetes, renal failure (serum creatinine >130 mmol/l), hepatic or pulmonary disease, unstable angina or myocardial infarction within the past 4 weeks were excluded. INTERVENTIONS Patients were randomised to receive either RIPC (n = 23) or control (n = 22) after anaesthesia. RIPC comprised three 5 min cycles of right forearm ischaemia, induced by inflating a blood pressure cuff on the upper arm to 200 mm Hg, with an intervening 5 min reperfusion. The control group had a deflated cuff placed on the upper arm for 30 min. MAIN OUTCOME MEASURES Serum troponin T was measured preoperatively and at 6, 12, 24, 48 and 72 h after surgery and the area under the curve (AUC at 72 h) calculated. RESULTS RIPC reduced absolute serum troponin T release by 42.4% (mean (SD) AUC at 72 h: 31.53 (24.04) microg/l.72 h in controls vs 18.16 (6.67) microg/l.72 h in RIPC; 95% CI 2.4 to 24.3; p = 0.019). CONCLUSIONS Remote ischaemic preconditioning induced by brief ischaemia and reperfusion of the arm reduces myocardial injury in CABG surgery patients undergoing cold-blood cardioplegia, making this non-invasive cardioprotective technique widely applicable clinically. TRIAL REGISTRATION NUMBER NCT00397163.
Collapse
|
66
|
Lachniet J, Afanasev A, Arenhövel H, Brooks WK, Gilfoyle GP, Higinbotham D, Jeschonnek S, Quinn B, Vineyard MF, Adams G, Adhikari KP, Amaryan MJ, Anghinolfi M, Asavapibhop B, Asryan G, Avakian H, Bagdasaryan H, Baillie N, Ball JP, Baltzell NA, Barrow S, Batourine V, Battaglieri M, Beard K, Bedlinskiy I, Bektasoglu M, Bellis M, Benmouna N, Berman BL, Biselli AS, Bonner BE, Bookwalter C, Bouchigny S, Boiarinov S, Bradford R, Branford D, Briscoe WJ, Bültmann S, Burkert VD, Calarco JR, Careccia SL, Carman DS, Casey L, Cheng L, Cole PL, Coleman A, Collins P, Cords D, Corvisiero P, Crabb D, Crede V, Cummings JP, Dale D, Daniel A, Dashyan N, De Masi R, De Vita R, De Sanctis E, Degtyarenko PV, Denizli H, Dennis L, Deur A, Dhamija S, Dharmawardane KV, Dhuga KS, Dickson R, Djalali C, Dodge GE, Doughty D, Dragovitsch P, Dugger M, Dytman S, Dzyubak OP, Egiyan H, Egiyan KS, El Fassi L, Elouadrhiri L, Empl A, Eugenio P, Fatemi R, Fedotov G, Fersch R, Feuerbach RJ, Forest TA, Fradi A, Gabrielyan MY, Garçon M, Gavalian G, Gevorgyan N, Giovanetti KL, Girod FX, Goetz JT, Gohn W, Golovatch E, Gothe RW, Graham L, Griffioen KA, Guidal M, Guillo M, Guler N, Guo L, Gyurjyan V, Hadjidakis C, Hafidi K, Hakobyan H, Hanretty C, Hardie J, Hassall N, Heddle D, Hersman FW, Hicks K, Hleiqawi I, Holtrop M, Hu J, Huertas M, Hyde-Wright CE, Ilieva Y, Ireland DG, Ishkhanov BS, Isupov EL, Ito MM, Jenkins D, Jo HS, Johnstone JR, Joo K, Juengst HG, Kageya T, Kalantarians N, Keller D, Kellie JD, Khandaker M, Khetarpal P, Kim KY, Kim K, Kim W, Klein A, Klein FJ, Klusman M, Konczykowski P, Kossov M, Kramer LH, Kubarovsky V, Kuhn J, Kuhn SE, Kuleshov SV, Kuznetsov V, Laget JM, Langheinrich J, Lawrence D, Lima ACS, Livingston K, Lowry M, Lu HY, Lukashin K, Maccormick M, Malace S, Manak JJ, Markov N, Mattione P, McAleer S, McCracken ME, McKinnon B, McNabb JWC, Mecking BA, Mestayer MD, Meyer CA, Mibe T, Mikhailov K, Mineeva T, Minehart R, Mirazita M, Miskimen R, Mokeev V, Moreno B, Moriya K, Morrow SA, Moteabbed M, Mueller J, Munevar E, Mutchler GS, Nadel-Turonski P, Nasseripour R, Niccolai S, Niculescu G, Niculescu I, Niczyporuk BB, Niroula MR, Niyazov RA, Nozar M, O'Rielly GV, Osipenko M, Ostrovidov AI, Park K, Park S, Pasyuk E, Paterson C, Pereira SA, Philips SA, Pierce J, Pivnyuk N, Pocanic D, Pogorelko O, Polli E, Popa I, Pozdniakov S, Preedom BM, Price JW, Prok Y, Protopopescu D, Qin LM, Raue BA, Riccardi G, Ricco G, Ripani M, Ritchie BG, Rosner G, Rossi P, Rowntree D, Rubin PD, Sabatié F, Saini MS, Salamanca J, Salgado C, Sandorfi A, Santoro JP, Sapunenko V, Schott D, Schumacher RA, Serov VS, Sharabian YG, Sharov D, Shaw J, Shvedunov NV, Skabelin AV, Smith ES, Smith LC, Sober DI, Sokhan D, Starostin A, Stavinsky A, Stepanyan S, Stepanyan SS, Stokes BE, Stoler P, Stopani KA, Strakovsky II, Strauch S, Suleiman R, Taiuti M, Taylor S, Tedeschi DJ, Thompson R, Tkabladze A, Tkachenko S, Ungaro M, Vlassov AV, Watts DP, Wei X, Weinstein LB, Weygand DP, Williams M, Wolin E, Wood MH, Yegneswaran A, Yun J, Yurov M, Zana L, Zhang J, Zhao B, Zhao ZW. Precise measurement of the neutron magnetic form factor G(M)n in the few-GeV2 region. PHYSICAL REVIEW LETTERS 2009; 102:192001. [PMID: 19518944 DOI: 10.1103/physrevlett.102.192001] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/10/2008] [Indexed: 05/27/2023]
Abstract
The neutron elastic magnetic form factor was extracted from quasielastic electron scattering on deuterium over the range Q;{2}=1.0-4.8 GeV2 with the CLAS detector at Jefferson Lab. High precision was achieved with a ratio technique and a simultaneous in situ calibration of the neutron detection efficiency. Neutrons were detected with electromagnetic calorimeters and time-of-flight scintillators at two beam energies. The dipole parametrization gives a good description of the data.
Collapse
|
67
|
Nozar M, Salgado C, Weygand DP, Guo L, Adams G, Li J, Eugenio P, Amaryan MJ, Anghinolfi M, Asryan G, Avakian H, Bagdasaryan H, Baillie N, Ball JP, Baltzell NA, Barrow S, Battaglieri M, Bedlinskiy I, Bektasoglu M, Bellis M, Benmouna N, Berman BL, Biselli AS, Blaszczyk L, Bonner BE, Bouchigny S, Boiarinov S, Bradford R, Branford D, Briscoe WJ, Brooks WK, Bültmann S, Burkert VD, Butuceanu C, Calarco JR, Careccia SL, Carman DS, Carnahan B, Casey L, Cazes A, Chen S, Cheng L, Cole PL, Collins P, Coltharp P, Cords D, Corvisiero P, Crabb D, Crannell H, Crede V, Cummings JP, Dale D, Dashyan N, De Masi R, De Vita R, De Sanctis E, Degtyarenko PV, Denizli H, Dennis L, Deur A, Dharmawardane KV, Dhuga KS, Dickson R, Djalali C, Dodge GE, Doughty D, Dugger M, Dytman S, Dzyubak OP, Egiyan H, Egiyan KS, El Fassi L, Elouadrhiri L, Fatemi R, Fedotov G, Feuerbach RJ, Forest TA, Fradi A, Funsten H, Garçon M, Gavalian G, Gevorgyan N, Gilfoyle GP, Giovanetti KL, Girod FX, Goetz JT, Gothe RW, Griffioen KA, Guidal M, Guillo M, Guler N, Gyurjyan V, Hadjidakis C, Hafidi K, Hakobyan H, Hanretty C, Hardie J, Hassall N, Heddle D, Hersman FW, Hicks K, Hleiqawi I, Holtrop M, Hyde-Wright CE, Ilieva Y, Ireland DG, Ishkhanov BS, Isupov EL, Ito MM, Jenkins D, Jo HS, Johnstone JR, Joo K, Juengst HG, Kalantarians N, Kellie JD, Khandaker M, Kim W, Klein A, Klein FJ, Kossov M, Krahn Z, Kramer LH, Kubarovsky V, Kuhn J, Kuhn SE, Kuleshov SV, Kuznetsov V, Lachniet J, Laget JM, Langheinrich J, Lawrence D, Livingston K, Lu HY, Maccormick M, Markov N, Mattione P, McAleer S, McKinnon B, McNabb JWC, Mecking BA, Mehrabyan S, Mestayer MD, Meyer CA, Mibe T, Mikhailov K, Mirazita M, Miskimen R, Mokeev V, Moreno B, Moriya K, Morrow SA, Moteabbed M, Mueller J, Munevar E, Mutchler GS, Nadel-Turonski P, Nasseripour R, Niccolai S, Niculescu G, Niculescu I, Niczyporuk BB, Niroula MR, Niyazov RA, O'Rielly GV, Osipenko M, Ostrovidov AI, Park K, Pasyuk E, Paterson C, Anefalos Pereira S, Philips SA, Pierce J, Pivnyuk N, Pocanic D, Pogorelko O, Polli E, Popa I, Pozdniakov S, Preedom BM, Price JW, Prok Y, Protopopescu D, Qin LM, Raue BA, Riccardi G, Ricco G, Ripani M, Ritchie BG, Ronchetti F, Rosner G, Rossi P, Rubin PD, Sabatié F, Salamanca J, Santoro JP, Sapunenko V, Schumacher RA, Serov VS, Sharabian YG, Sharov D, Shvedunov NV, Skabelin AV, Smith ES, Smith LC, Sober DI, Sokhan D, Stavinsky A, Stepanyan SS, Stepanyan S, Stokes BE, Stoler P, Strakovsky II, Strauch S, Taiuti M, Tedeschi DJ, Thoma U, Tkabladze A, Tkachenko S, Todor L, Ungaro M, Vineyard MF, Vlassov AV, Watts DP, Weinstein LB, Williams M, Wolin E, Wood MH, Yegneswaran A, Zana L, Zhang J, Zhao B, Zhao ZW. Search for the photoexcitation of exotic mesons in the pi+pi+pi- system. PHYSICAL REVIEW LETTERS 2009; 102:102002. [PMID: 19392105 DOI: 10.1103/physrevlett.102.102002] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/06/2008] [Indexed: 05/27/2023]
Abstract
A search for exotic mesons in the pi;{+}pi;{+}pi;{-} system photoproduced by the charge exchange reaction gammap-->pi;{+}pi;{+}pi;{-}(n) was carried out by the CLAS Collaboration at Jefferson Lab. A tagged-photon beam with energies in the 4.8 to 5.4 GeV range, produced through bremsstrahlung from a 5.744 GeV electron beam, was incident on a liquid-hydrogen target. A partial wave analysis was performed on a sample of 83 000 events, the highest such statistics to date in this reaction at these energies. The main objective of this study was to look for the photoproduction of an exotic J;{PC}=1;{-+} resonant state in the 1 to 2 GeV mass range. Our partial wave analysis shows production of the a_{2}(1320) and the pi_{2}(1670) mesons, but no evidence for the a_{1}(1260), nor the pi_{1}(1600) exotic state at the expected levels. An upper limit of 13.5 nb is determined for the exotic pi_{1}(1600) cross section, less than 2% of the a_{2}(1320) production.
Collapse
|
68
|
Battaglieri M, De Vita R, Szczepaniak AP, Adhikari KP, Aghasyan M, Amaryan MJ, Ambrozewicz P, Anghinolfi M, Asryan G, Avakian H, Bagdasaryan H, Baillie N, Ball JP, Baltzell NA, Batourine V, Bedlinskiy I, Bellis M, Benmouna N, Berman BL, Bibrzycki L, Biselli AS, Bookwalter C, Bouchigny S, Boiarinov S, Bradford R, Branford D, Briscoe WJ, Brooks WK, Bültmann S, Burkert VD, Calarco JR, Careccia SL, Carman DS, Casey L, Chen S, Cheng L, Clinton E, Cole PL, Collins P, Crabb D, Crannell H, Crede V, Cummings JP, Dale D, Daniel A, Dashyan N, De Masi R, De Sanctis E, Degtyarenko PV, Deur A, Dhamija S, Dharmawardane KV, Dickson R, Djalali C, Dodge GE, Donnelly J, Doughty D, Dugger M, Dzyubak OP, Egiyan H, Egiyan KS, El Fassi L, Elouadrhiri L, Eugenio P, Fedotov G, Fersch R, Forest TA, Fradi A, Gabrielyan MY, Gan L, Garçon M, Gasparian A, Gavalian G, Gevorgyan N, Gilfoyle GP, Giovanetti KL, Girod FX, Glamazdin O, Goett J, Goetz JT, Gohn W, Golovatch E, Gordon CIO, Gothe RW, Graham L, Griffioen KA, Guidal M, Guler N, Guo L, Gyurjyan V, Hadjidakis C, Hafidi K, Hakobyan H, Hakobyan RS, Hanretty C, Hardie J, Hassall N, Heddle D, Hersman FW, Hicks K, Hleiqawi I, Holtrop M, Hyde CE, Ilieva Y, Ireland DG, Ishkhanov BS, Isupov EL, Ito MM, Jenkins D, Jo HS, Johnstone JR, Joo K, Juengst HG, Kageya T, Kalantarians N, Keller D, Kellie JD, Khandaker M, Khetarpal P, Kim W, Klein A, Klein FJ, Klimenko AV, Konczykowski P, Kossov M, Krahn Z, Kramer LH, Kubarovsky V, Kuhn J, Kuhn SE, Kuleshov SV, Kuznetsov V, Lachniet J, Laget JM, Langheinrich J, Lawrence D, Lee T, Lesniak L, Li J, Livingston K, Lowry M, Lu HY, Maccormick M, Malace S, Markov N, Mattione P, McCracken ME, McKinnon B, Mecking BA, Melone JJ, Mestayer MD, Meyer CA, Mibe T, Mikhailov K, Mineeva T, Minehart R, Mirazita M, Miskimen R, Mochalov V, Mokeev V, Moreno B, Moriya K, Morrow SA, Moteabbed M, Munevar E, Mutchler GS, Nadel-Turonski P, Nakagawa I, Nasseripour R, Niccolai S, Niculescu G, Niculescu I, Niczyporuk BB, Niroula MR, Niyazov RA, Nozar M, Osipenko M, Ostrovidov AI, Park K, Park S, Pasyuk E, Paris M, Paterson C, Pereira SA, Pierce J, Pivnyuk N, Pocanic D, Pogorelko O, Pozdniakov S, Price JW, Prok Y, Protopopescu D, Raue BA, Riccardi G, Ricco G, Ripani M, Ritchie BG, Rosner G, Rossi P, Sabatié F, Saini MS, Salamanca J, Salgado C, Sandorfi A, Santoro JP, Sapunenko V, Schott D, Schumacher RA, Serov VS, Sharabian YG, Sharov D, Shvedunov NV, Smith ES, Smith LC, Sober DI, Sokhan D, Starostin A, Stavinsky A, Stepanyan S, Stepanyan SS, Stokes BE, Stoler P, Stopani KA, Strakovsky II, Strauch S, Taiuti M, Tedeschi DJ, Teymurazyan A, Tkabladze A, Tkachenko S, Todor L, Tur C, Ungaro M, Vineyard MF, Vlassov AV, Watts DP, Wei X, Weinstein LB, Weygand DP, Williams M, Wolin E, Wood MH, Yegneswaran A, Yurov M, Zana L, Zhang J, Zhao B, Zhao ZW. Measurement of direct f0(980) photoproduction on the proton. PHYSICAL REVIEW LETTERS 2009; 102:102001. [PMID: 19392104 DOI: 10.1103/physrevlett.102.102001] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/11/2008] [Indexed: 05/27/2023]
Abstract
We report on the results of the first measurement of exclusive f_{0}(980) meson photoproduction on protons for E_{gamma}=3.0-3.8 GeV and -t=0.4-1.0 GeV2. Data were collected with the CLAS detector at the Thomas Jefferson National Accelerator Facility. The resonance was detected via its decay in the pi;{+}pi;{-} channel by performing a partial wave analysis of the reaction gammap-->ppi;{+}pi;{-}. Clear evidence of the f_{0}(980) meson was found in the interference between P and S waves at M_{pi;{+}pi;{-}} approximately 1 GeV. The S-wave differential cross section integrated in the mass range of the f_{0}(980) was found to be a factor of about 50 smaller than the cross section for the rho meson. This is the first time the f_{0}(980) meson has been measured in a photoproduction experiment.
Collapse
|
69
|
Del Prato S, Blonde L, Martinez L, Göke B, Woo V, Millward A, Gomis R, Canovatchel B, Strack T, Lawrence D, Freemantle N. The effect of the availability of inhaled insulin on glycaemic control in patients with Type 2 diabetes failing on oral therapy: the evaluation of Exubera as a therapeutic option on insulin initiation and improvement in glycaemic control in clinical practice (EXPERIENCE) trial. Diabet Med 2008; 25:662-70. [PMID: 18435781 DOI: 10.1111/j.1464-5491.2008.02438.x] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
AIM To examine the impact of inhaled human insulin (Exubera, EXU) on patient or physician willingness to adopt insulin after oral glucose-lowering agent failure. METHODS During a randomized controlled trial in primary, secondary and tertiary care in Europe and North America, 739 patients using >or= 2 oral glucose-lowering agents with glycated haemoglobin (HbA(1c)) >or= 8.0% were assigned to two treatment groups: Group 1 (standard care with the option of EXU) or Group 2 (standard care only). Standard care included adjusting oral therapy (optimizing current regimen or adding/omitting agents) and/or initiating subcutaneous (s.c.) insulin. The primary endpoint was difference in HbA(1c) between randomized groups at 26 weeks. Secondary outcomes included differences in the rate of uptake of insulin therapy, proportion achieving satisfactory glycaemic control, treatment satisfaction and safety outcomes. RESULTS At baseline, insulin was initiated by more [odds ratio 6.0; 95% confidence interval (CI) 4.2 to 8.8; P < 0.0001] patients in Group 1 (86.2%; 76.7% EXU plus 9.5% s.c.) than Group 2 (50.7%; s.c. insulin only). At 26 weeks, mean (sd) changes in HbA(1c) from baseline were -2.0% (1.2%) and -1.7% (1.3%) in Groups 1 and 2, respectively, a difference of -0.2% (95% CI: -0.1% to -0.4%; P = 0.004). In Group 1, 45% of patients achieved an HbA(1c)<or= 7.0% by 26 weeks compared with 39% in Group 2 (P = 0.02). CONCLUSION The availability of EXU may increase initiation of insulin, thereby contributing to improved overall glycaemic control in patients with Type 2 diabetes inadequately controlled on two or more oral glucose-lowering agents.
Collapse
|
70
|
Ashkenazi A, Wagner K, Punnnoose E, Lawrence D, Pitti R, Amler L. Identification of potentially predictive biomarkers for tumor sensitivity to proapoptotic receptor agonists. J Clin Oncol 2008. [DOI: 10.1200/jco.2008.26.15_suppl.14505] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
|
71
|
Chadha MK, Ashraf U, Payne V, Silliman C, Escott P, Lawrence D, Tian L, Levine E, Trump DL. Phase II trial of fulvestrant in castration resistant prostate cancer. J Clin Oncol 2008. [DOI: 10.1200/jco.2008.26.15_suppl.16079] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
|
72
|
Girod FX, Niyazov RA, Avakian H, Ball J, Bedlinskiy I, Burkert VD, De Masi R, Elouadrhiri L, Garçon M, Guidal M, Jo HS, Joo K, Kubarovsky V, Kuleshov SV, MacCormick M, Niccolai S, Pogorelko O, Sabatié F, Stepanyan S, Stoler P, Ungaro M, Zhao B, Amaryan MJ, Ambrozewicz P, Anghinolfi M, Asryan G, Bagdasaryan H, Baillie N, Ball JP, Baltzell NA, Batourine V, Battaglieri M, Bellis M, Benmouna N, Berman BL, Biselli AS, Blaszczyk L, Bouchigny S, Boiarinov S, Bradford R, Branford D, Briscoe WJ, Brooks WK, Bültmann S, Butuceanu C, Calarco JR, Careccia SL, Carman DS, Casey L, Chen S, Cheng L, Cole PL, Collins P, Coltharp P, Crabb D, Crede V, Dashyan N, De Sanctis E, De Vita R, Degtyarenko PV, Deur A, Dharmawardane KV, Dickson R, Djalali C, Dodge GE, Donnelly J, Doughty D, Dugger M, Dzyubak OP, Egiyan H, Egiyan KS, El Fassi L, Eugenio P, Fedotov G, Feldman G, Funsten H, Gavalian G, Gilfoyle GP, Giovanetti KL, Goetz JT, Gonenc A, Gothe RW, Griffioen KA, Guler N, Guo L, Gyurjyan V, Hafidi K, Hakobyan H, Hanretty C, Hersman FW, Hicks K, Hleiqawi I, Holtrop M, Hyde CE, Ilieva Y, Ireland DG, Ishkhanov BS, Isupov EL, Ito MM, Jenkins D, Johnstone JR, Juengst HG, Kalantarians N, Kellie JD, Khandaker M, Kim W, Klein A, Klein FJ, Klimenko AV, Kossov M, Krahn Z, Kramer LH, Kuhn J, Kuhn SE, Lachniet J, Laget JM, Langheinrich J, Lawrence D, Lee T, Livingston K, Lu HY, Markov N, Mattione P, Mazouz M, McKinnon B, Mecking BA, Mestayer MD, Meyer CA, Mibe T, Michel B, Mikhailov K, Mirazita M, Miskimen R, Mokeev V, Moriya K, Morrow SA, Moteabbed M, Munevar E, Mutchler GS, Nadel-Turonski P, Nasseripour R, Niculescu G, Niculescu I, Niczyporuk BB, Niroula MR, Nozar M, Osipenko M, Ostrovidov AI, Park K, Pasyuk E, Paterson C, Anefalos Pereira S, Pierce J, Pivnyuk N, Pocanic D, Pozdniakov S, Price JW, Procureur S, Prok Y, Protopopescu D, Raue BA, Ricco G, Ripani M, Ritchie BG, Rosner G, Rossi P, Salamanca J, Salgado C, Santoro JP, Sapunenko V, Schumacher RA, Serov VS, Sharabian YG, Sharov D, Shvedunov NV, Smith ES, Smith LC, Sober DI, Sokhan D, Stavinsky A, Stepanyan SS, Stokes BE, Strakovsky II, Strauch S, Taiuti M, Tedeschi DJ, Tkabladze A, Tkachenko S, Tur C, Vineyard MF, Vlassov AV, Voutier E, Watts DP, Weinstein LB, Weygand DP, Williams M, Wolin E, Wood MH, Yegneswaran A, Zana L, Zhang J, Zhao ZW. Measurement of deeply virtual compton scattering beam-spin asymmetries. PHYSICAL REVIEW LETTERS 2008; 100:162002. [PMID: 18518188 DOI: 10.1103/physrevlett.100.162002] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/06/2007] [Indexed: 05/26/2023]
Abstract
The beam-spin asymmetries in the hard exclusive electroproduction of photons on the proton (e p-->epgamma) were measured over a wide kinematic range and with high statistical accuracy. These asymmetries result from the interference of the Bethe-Heitler process and of deeply virtual Compton scattering. Over the whole kinematic range (x(B) from 0.11 to 0.58, Q2 from 1 to 4.8 GeV2, -t from 0.09 to 1.8 GeV2), the azimuthal dependence of the asymmetries is compatible with expectations from leading-twist dominance, A approximately a sinphi/(1+c cosphi). This extensive set of data can thus be used to constrain significantly the generalized parton distributions of the nucleon in the valence quark sector.
Collapse
|
73
|
|
74
|
Ireland DG, McKinnon B, Protopopescu D, Ambrozewicz P, Anghinolfi M, Asryan G, Avakian H, Bagdasaryan H, Baillie N, Ball JP, Baltzell NA, Batourine V, Battaglieri M, Bedlinskiy I, Bellis M, Benmouna N, Berman BL, Biselli AS, Blaszczyk L, Bouchigny S, Boiarinov S, Bradford R, Branford D, Briscoe WJ, Brooks WK, Burkert VD, Butuceanu C, Calarco JR, Careccia SL, Carman DS, Casey L, Chen S, Cheng L, Cole PL, Collins P, Coltharp P, Crabb D, Crede V, Dashyan N, De Masi R, De Vita R, De Sanctis E, Degtyarenko PV, Deur A, Dickson R, Djalali C, Dodge GE, Donnelly J, Doughty D, Dugger M, Dzyubak OP, Egiyan KS, El Fassi L, Elouadrhiri L, Eugenio P, Fedotov G, Feldman G, Fradi A, Funsten H, Garçon M, Gavalian G, Gevorgyan N, Gilfoyle GP, Giovanetti KL, Girod FX, Goetz JT, Gohn W, Gonenc A, Gothe RW, Griffioen KA, Guidal M, Guler N, Guo L, Gyurjyan V, Hafidi K, Hakobyan H, Hanretty C, Hassall N, Hersman FW, Hleiqawi I, Holtrop M, Hyde-Wright CE, Ilieva Y, Ishkhanov BS, Isupov EL, Jenkins D, Jo HS, Johnstone JR, Joo K, Juengst HG, Kalantarians N, Kellie JD, Khandaker M, Kim W, Klein A, Klein FJ, Kossov M, Krahn Z, Kramer LH, Kubarovsky V, Kuhn J, Kuleshov SV, Kuznetsov V, Lachniet J, Laget JM, Langheinrich J, Lawrence D, Livingston K, Lu HY, Maccormick M, Markov N, Mattione P, Mecking BA, Mestayer MD, Meyer CA, Mibe T, Mikhailov K, Mirazita M, Miskimen R, Mokeev V, Moreno B, Moriya K, Morrow SA, Moteabbed M, Munevar E, Mutchler GS, Nadel-Turonski P, Nasseripour R, Niccolai S, Niculescu G, Niculescu I, Niczyporuk BB, Niroula MR, Niyazov RA, Nozar M, Osipenko M, Ostrovidov AI, Park K, Pasyuk E, Paterson C, Pereira SA, Pierce J, Pivnyuk N, Pogorelko O, Pozdniakov S, Price JW, Procureur S, Prok Y, Raue BA, Ricco G, Ripani M, Ritchie BG, Ronchetti F, Rosner G, Rossi P, Sabatié F, Salamanca J, Salgado C, Santoro JP, Sapunenko V, Schumacher RA, Serov VS, Sharabian YG, Sharov D, Shvedunov NV, Smith LC, Sober DI, Sokhan D, Stavinsky A, Stepanyan SS, Stepanyan S, Stokes BE, Stoler P, Strauch S, Taiuti M, Tedeschi DJ, Tkabladze A, Tkachenko S, Tur C, Ungaro M, Vineyard MF, Vlassov AV, Watts DP, Weinstein LB, Weygand DP, Williams M, Wolin E, Wood MH, Yegneswaran A, Zana L, Zhang J, Zhao B, Zhao ZW. Bayesian analysis of pentaquark signals from CLAS data. PHYSICAL REVIEW LETTERS 2008; 100:052001. [PMID: 18352361 DOI: 10.1103/physrevlett.100.052001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/20/2007] [Indexed: 05/26/2023]
Abstract
We examine the results of two measurements by the CLAS collaboration, one of which claimed evidence for a Theta(+) pentaquark, while the other found no such evidence. The unique feature of these two experiments was that they were performed with the same experimental setup. Using a Bayesian analysis, we find that the results of the two experiments are in fact compatible with each other, but that the first measurement did not contain sufficient information to determine unambiguously the existence of a Theta(+). Further, we suggest a means by which the existence of a new candidate particle can be tested in a rigorous manner.
Collapse
|
75
|
Adams C, Totpal K, Lawrence D, Marsters S, Pitti R, Yee S, Ross S, Deforge L, Koeppen H, Sagolla M, Compaan D, Lowman H, Hymowitz S, Ashkenazi A. Structural and functional analysis of the interaction between the agonistic monoclonal antibody Apomab and the proapoptotic receptor DR5. Cell Death Differ 2008; 15:751-61. [PMID: 18219321 DOI: 10.1038/sj.cdd.4402306] [Citation(s) in RCA: 114] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
Abstract
Activation of the proapoptotic receptor death receptor5 (DR5) in various cancer cells triggers programmed cell death through the extrinsic pathway. We have generated a fully human monoclonal antibody (Apomab) that induces tumor cell apoptosis through DR5 and investigated the structural features of its interaction with DR5. Biochemical studies showed that Apomab binds DR5 tightly and selectively. X-ray crystallographic analysis of the complex between the Apomab Fab fragment and the DR5 ectodomain revealed an interaction epitope that partially overlaps with both regions of the Apo2 ligand/tumor necrosis factor-related apoptosis-inducing ligand binding site. Apomab induced DR5 clustering at the cell surface and stimulated a death-inducing signaling complex containing the adaptor molecule Fas-associated death domain and the apoptosis-initiating protease caspase-8. Fc crosslinking further augmented Apomab's proapoptotic activity. In vitro, Apomab triggered apoptosis in cancer cells, while sparing normal hepatocytes even upon anti-Fc crosslinking. In vivo, Apomab exerted potent antitumor activity as a single agent or in combination with chemotherapy in xenograft models, including those based on colorectal, non-small cell lung and pancreatic cancer cell lines. These results provide structural and functional insight into the interaction of Apomab with DR5 and support further investigation of this antibody for cancer therapy.
Collapse
|