51
|
Chang HK, Kim SY, Kim JI, Kim SI, Whang JK, Choi JY, Park JM, Jung ES, Rha SE, Kim DG, Moon IS, Lee MD. Ten-Year Experience With Bowel Transplantation at Seoul St. Mary's Hospital. Transplant Proc 2017; 48:473-8. [PMID: 27109981 DOI: 10.1016/j.transproceed.2015.12.065] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2015] [Accepted: 12/29/2015] [Indexed: 12/12/2022]
Abstract
A retrospective review of intestinal transplantation (ITx) at Seoul St. Mary's Hospital was made by collecting clinical data over the past 10 years. Fifteen consecutive cases from 2004 were analyzed. Five children and 10 adults (6 months to 69 years of age) were included. Primary diseases in adults included 4 mesenteric vessel thromboses, 2 strangulations, and 1 each of visceral myopathy, malignant gastrointestinal stromal tumor (GIST), mesenteric lymphangiectasis, and injury. Pediatric cases involved 2 Hirschsprung disease, 2 visceral myopathy, and 1 necrotizing enterocolitis. Three of 7 stomas were closed using a serial transverse enteroplasty procedure before transplantation. The ITx were performed using 3 living-donor Itx, 12 deceased-donor ITx, 14 isolated Itx, and 1 modified multivisceral transplantation. Daclizumab, basiliximab, alemtusumab, or basiliximab with rabbit antithymocyte globulin (rATG) was used for the induction; tacrolimus monotherapy was used as the basic maintenance immunosuppressant; and m-TOR inhibitor was used for renal dysfunction patients. Seven cases of acute cellular rejection were treated with rATG. Three cases of antibody-mediated rejection were treated with rituximab alone or with rituximab and bortezomib combination. There were 4 cases of early mortality within 6 months after Itx. Causes of death were declamping shock, cardiac tamponade with acute cellular rejection, dysmotility, and sepsis. Surgical complications consisted of 1 feeding jejunostomy displacement, and a minor leakage at a colo-colostomy site. One-year survival of the patient and graft was 73.33% (Kaplan-Meier survival curve). Although the total number of ITx is small, its social impact has been remarkable in changing the related laws and reimbursement policy in Korea.
Collapse
|
52
|
Lee J, Jeong YH, Pittman J, Deguchi T, Johnston WM, Fields HW, Kim DG. Primary stability and viscoelastic displacement of mini-implant system under loading. Clin Biomech (Bristol, Avon) 2017; 41:28-33. [PMID: 27915135 DOI: 10.1016/j.clinbiomech.2016.11.004] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/11/2016] [Revised: 10/19/2016] [Accepted: 11/21/2016] [Indexed: 02/07/2023]
Abstract
BACKGROUND The objectives of the current study were to examine the effects of mini-implant diameters on 1) primary stability before bone properties are changed by active peri-implant bone remodeling and 2) the time-dependent displacement of mini-implant systems in bone under a functional radial loading and their associations with bone mineral density. METHODS Twenty one, 8mm length mini-implants (7 each for 1.4mm, 1.6mm, and 2mm diameters) were placed in mandibular sections of human cadavers (4 males and 3 females, average 69.7 (SD 13.1) years of age). Displacement of the mini-implant in wet bone was assessed during initial and subsequent continuous radial loading of 2N in the mediolateral direction for 2h. Mean, standard deviation and coefficient of variation of peri-implant bone mineral density were obtained using histograms of cone-beam computed tomography attenuation values. The cortical thickness along with the miniscrew site was also measured. FINDINGS The primary stability and displacement of mini-implants in bone were not significantly different between the 3 diameter groups (p>0.147, n=21). Moderate positive correlations of time-dependent viscoelastic displacement (creep) were found with bone mineral density variability independent of the mini-implant diameters (p>0.11). INTERPRETATION The post-implantation displacements of mini-implant suggested that the orthodontic treatment loading can develop micromotion between the mini-implant and surrounding bone leading to reduction of its primary stability. Current findings also provide an insight that peri-implant bone mineral density variability plays an important role in controlling displacement of the mini-implant, which determine its stability during early and prolonged orthodontic treatment loading periods.
Collapse
|
53
|
England GM, Moon ES, Roth J, Deguchi T, Firestone AR, Beck FM, Kim DG. Conditions and calibration to obtain comparable grey values between different clinical cone beam computed tomography scanners. Dentomaxillofac Radiol 2016; 46:20160322. [PMID: 27844482 DOI: 10.1259/dmfr.20160322] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022] Open
Abstract
OBJECTIVES The objective of the present study was to examine the grey value parameters and their magnitudes produced by CBCT and whether they are influenced by different scanners with various scanning conditions. METHODS An ATOM Max dental and diagnostic artificial head was scanned by two CBCT scanners (Planmeca and iCAT). Under full field of view with normal dose and ultralow-dose (ULD) conditions, the Planmeca scanner was examined for three scanning resolutions (200, 400, and 600 micron voxel sizes) and the iCAT scanner was tested for four scanning resolutions (200, 250, 300 and 400 micron voxel sizes). After 9 weeks, the artificial head was scanned again by the Planmeca scanner with the same scanning conditions. In addition, two hydroxyapatite phantoms (1220 and 1540 mg cm-3) were adhered on the artificial head and scanned using normal and ULD scanning conditions of 400 micron voxel size with both scanners. The grey value histogram of each region, which is proportional to the bone mineral density (BMD) histogram, was utilized to determine grey value distribution parameters and compare scanners (ANOVA, p < 0.05). RESULTS The different scanning conditions and the bilateral locations of the artificial head did not have significant effects on measurements of the grey value parameters (p > 0.436) with excellent repeatability. However, the iCAT scanner produced significantly different grey values from the Planmeca scanner (p < 0.001). CONCLUSIONS CBCT can assess BMD, while calibration of absolute measures is necessary to obtain comparable values between different scanners that are currently used to assess oral bone quantity and quality.
Collapse
|
54
|
Tee BC, Desai KGH, Kennedy KS, Sonnichsen B, Kim DG, Fields HW, Mallery SR, Schwendeman SP, Sun Z. Reconstructing jaw defects with MSCs and PLGA-encapsulated growth factors. Am J Transl Res 2016; 8:2693-2704. [PMID: 27398152 PMCID: PMC4931163] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2016] [Accepted: 05/07/2016] [Indexed: 06/06/2023]
Abstract
Cell and growth factor-based tissue engineering has shown great potentials for skeletal regeneration. This study tested its feasibility in reconstructing large mandibular defects and compared the efficacy of varied construction materials and sealing methods. Bilateral mandibular critical-size (5-cm(3)) defects were created on six 4-month-old domestic pigs, and grafted with β-tricalcium phosphate (βTCP) only (Group-A), βTCP with autologous bone marrow-derived mesenchymal stem cells (BM-MSCs) (Group-B), and βTCP with BM-MSCs and biodegradable poly(lactic-co-glycolic acid) (PLGA) microspheres containing bone morphogenetic protein-2 (BMP-2) and vascular endothelial growth factor (VEGF) (Group-C). The buccal sides of Groups-B/-C were either sealed by fibrin sealant or by a biodegradable PLGA barrier membrane before soft-tissue closure. Computed tomography (CT), microCT and histology analyses were performed 12 weeks postoperatively. In vitro data demonstrated that BM-MSCs, with MSC properties confirmed, remained vital after integration with βTCP; and PLGA microspheres exhibited an initial burst followed by slow and continuous release of growth factors over a period of 28 days. In vivo data demonstrated that Group-B/-C sites had significantly greater gap obliteration, higher tissue mineral densities and more residual βTCP granules (p<0.05, Kruskal-Wallis tests). Qualitatively, Group-B/-C defect sites had started remodeling while Group-A sites were mainly forming new bone to bridge the gaps. Furthermore, βTCP degradation was not mediated by macrophages or osteoclasts, and was significantly slowed down by sealing the defects with barrier membrane. Combined, these data present a promising formulation composed of βTCP granules, autologous MSCs, controlled-release growth factors and biodegradable PLGA barrier membrane for the reconstruction of critical-size mandibular defects.
Collapse
|
55
|
Deguchi T, Adachi R, Kamioka H, Kim DG, Fields HW, Takano-Yamamoto T, Ichikawa H, Yamashiro T. Effect of minocycline on induced glial activation by experimental tooth movement. Am J Orthod Dentofacial Orthop 2016; 149:881-8. [DOI: 10.1016/j.ajodo.2015.11.030] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2015] [Revised: 11/01/2015] [Accepted: 11/01/2015] [Indexed: 10/21/2022]
|
56
|
Kim DG, Elias KL, Jeong YH, Kwon HJ, Clements M, Brantley WA, Lee DJ, Han JS. Differences between buccal and lingual bone quality and quantity of peri-implant regions. J Mech Behav Biomed Mater 2016; 60:48-55. [PMID: 26773652 DOI: 10.1016/j.jmbbm.2015.12.036] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2015] [Revised: 12/22/2015] [Accepted: 12/23/2015] [Indexed: 10/22/2022]
Abstract
The objective of the current study was to examine whether peri-implant bone tissue properties are different between the buccal and lingual regions treated by growth factors. Four dental implant groups were used: titanium (Ti) implants, alumina-blasted zirconia implants (ATZ-N), alumina-blasted zirconia implants with demineralized bone matrix (DBM) (ATZ-D), and alumina-blasted zirconia implants with rhBMP-2 (ATZ-B). These implants were placed in mandibles of six male dogs. Nanoindentation elastic modulus (E) and plastic hardness (H) were measured for the buccal and lingual bone tissues adjacent and away from the implants at 3 and 6 weeks post-implantation. A total of 2281 indentations were conducted for 48 placed implants. The peri-implant buccal region had less bone quantity resulting from lower height and narrower width of bone tissue than the lingual region. Buccal bone tissues had significant greater mean values of E and H than lingual bone tissues at each distance and healing period (p<0.007). Nearly all implant treatment groups displayed lower mean values of the E at the lingual bone tissues than at the buccal bone tissues (p<0.046) although the difference was not significant for the Ti implant group (p=0.758). The DBM and rhBMP-2 treatments stimulated more peri-implant bone remodeling at the lingual region, producing more immature new bone tissues with lower E than at the buccal region. This finding suggests that the growth factor treatments to the zirconia implant system may help balance the quantity and quality differences between the peri-implant bone tissues.
Collapse
|
57
|
Ray TJ, McGraw WS, Sun Z, Jeon M, Johnson T, Cheffins K, Daegling DJ, Kim DG. Mandibular bone mineral density variation in three West African Cercopithecoid monkey species: Associations with diet and feeding behavior. Arch Oral Biol 2015; 60:1714-20. [DOI: 10.1016/j.archoralbio.2015.09.011] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2015] [Revised: 09/08/2015] [Accepted: 09/15/2015] [Indexed: 11/29/2022]
|
58
|
Oh DS, Koch A, Eisig S, Kim SG, Kim YH, Kim DG, Shim JH. Distinctive Capillary Action by Micro-channels in Bone-like Templates can Enhance Recruitment of Cells for Restoration of Large Bony Defect. J Vis Exp 2015. [PMID: 26380953 PMCID: PMC4692596 DOI: 10.3791/52947] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022] Open
Abstract
Without an active, thriving cell population that is well-distributed and stably anchored to the inserted template, exceptional bone regeneration does not occur. With conventional templates, the absence of internal micro-channels results in the lack of cell infiltration, distribution, and inhabitance deep inside the templates. Hence, a highly porous and uniformly interconnected trabecular-bone-like template with micro-channels (biogenic microenvironment template; BMT) has been developed to address these obstacles. The novel BMT was created by innovative concepts (capillary action) and fabricated with a sponge-template coating technique. The BMT consists of several structural components: inter-connected primary-pores (300-400 µm) that mimic pores in trabecular bone, micro-channels (25-70 µm) within each trabecula, and nanopores (100-400 nm) on the surface to allow cells to anchor. Moreover, the BMT has been documented by mechanical test study to have similar mechanical strength properties to those of human trabecular bone (~3.8 MPa)12. The BMT exhibited high absorption, retention, and habitation of cells throughout the bridge-shaped (Π) templates (3 cm height and 4 cm length). The cells that were initially seeded into one end of the templates immediately mobilized to the other end (10 cm distance) by capillary action of the BMT on the cell media. After 4 hr, the cells homogenously occupied the entire BMT and exhibited normal cellular behavior. The capillary action accounted for the infiltration of the cells suspended in the media and the distribution (active migration) throughout the BMT. Having observed these capabilities of the BMT, we project that BMTs will absorb bone marrow cells, growth factors, and nutrients from the periphery under physiological conditions. The BMT may resolve current limitations via rapid infiltration, homogenous distribution and inhabitance of cells in large, volumetric templates to repair massive skeletal defects.
Collapse
|
59
|
Cho YD, Shin JC, Yoon HI, Ku Y, Ryoo HM, Kim DJ, Kim DG, Han JS. Characterization of Human Gingival Fibroblasts on Zirconia Surfaces Containing Niobium Oxide. MATERIALS (BASEL, SWITZERLAND) 2015; 8:6018-6028. [PMID: 28793548 PMCID: PMC5512668 DOI: 10.3390/ma8095288] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/11/2015] [Revised: 08/25/2015] [Accepted: 09/02/2015] [Indexed: 11/17/2022]
Abstract
It was indicated that tetragonal zirconia polycrystal (TZP) containing yttria (Y₂O₃) and niobium oxide (Nb₂O₅) ((Y,Nb)-TZP) could be an adequate dental material to be used at esthetically important sites. The (Y,Nb)-TZP was also proved to possess its osteogenic potential comparable with those conventional dental implant material, titanium (Ti). The objective of the current study was to characterize cellular response of human gingival fibroblasts (HGFs) to smooth and rough surfaces of the (Y,Nb)-TZP disc, which were obtained by polishing and sandblasting, respectively. Various microscopic, biochemical, and molecular techniques were used to investigate the disc surfaces and cellular responses for the experimental (Y,Nb)-TZP and the comparing Ti groups. Sandblasted rough (Y,Nb)-TZP (Zir-R) discs had the highest surface roughness. HGFs cultured on polished (Y,Nb)-TZP (Zir) showed a rounded cell morphology and light spreading at 6 h after seeding and its proliferation rate significantly increased during seven days of culture compared to other surfaces. The mRNA expressions of type I collagen, integrin α2 and β1 were significantly stimulated for the Zir group at 24 h after seeding. The current findings, combined with the previous results, indicate that (Y,Nb)-TZP provides appropriate surface condition for osseointegration at the fixture level and for peri-implant mucosal sealing at the abutment level producing a suitable candidate for dental implantation with an expected favorable clinical outcome.
Collapse
|
60
|
Nam J, Perera P, Gordon R, Jeong YH, Blazek AD, Kim DG, Tee BC, Sun Z, Eubank TD, Zhao Y, Lablebecioglu B, Liu S, Litsky A, Weisleder NL, Lee BS, Butterfield T, Schneyer AL, Agarwal S. Follistatin-like 3 is a mediator of exercise-driven bone formation and strengthening. Bone 2015; 78:62-70. [PMID: 25937185 PMCID: PMC4466155 DOI: 10.1016/j.bone.2015.04.038] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/23/2015] [Revised: 04/15/2015] [Accepted: 04/24/2015] [Indexed: 11/17/2022]
Abstract
Exercise is vital for maintaining bone strength and architecture. Follistatin-like 3 (FSTL3), a member of follistatin family, is a mechanosensitive protein upregulated in response to exercise and is involved in regulating musculoskeletal health. Here, we investigated the potential role of FSTL3 in exercise-driven bone remodeling. Exercise-dependent regulation of bone structure and functions was compared in mice with global Fstl3 gene deletion (Fstl3-/-) and their age-matched Fstl3+/+ littermates. Mice were exercised by low-intensity treadmill walking. The mechanical properties and mineralization were determined by μCT, three-point bending test and sequential incorporation of calcein and alizarin complexone. ELISA, Western-blot analysis and qRT-PCR were used to analyze the regulation of FSTL3 and associated molecules in the serum specimens and tissues. Daily exercise significantly increased circulating FSTL3 levels in mice, rats and humans. Compared to age-matched littermates, Fstl3-/- mice exhibited significantly lower fracture tolerance, having greater stiffness, but lower strain at fracture and yield energy. Furthermore, increased levels of circulating FSTL3 in young mice paralleled greater strain at fracture compared to the lower levels of FSTL3 in older mice. More significantly, Fstl3-/- mice exhibited loss of mechanosensitivity and irresponsiveness to exercise-dependent bone formation as compared to their Fstl3+/+ littermates. In addition, FSTL3 gene deletion resulted in loss of exercise-dependent sclerostin regulation in osteocytes and osteoblasts, as compared to Fstl3+/+ osteocytes and osteoblasts, in vivo and in vitro. The data identify FSTL3 as a critical mediator of exercise-dependent bone formation and strengthening and point to its potential role in bone health and in musculoskeletal diseases.
Collapse
|
61
|
Kim HL, Jung GY, Yoon JH, Han JS, Park YJ, Kim DG, Zhang M, Kim DJ. Preparation and characterization of nano-sized hydroxyapatite/alginate/chitosan composite scaffolds for bone tissue engineering. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2015; 54:20-5. [DOI: 10.1016/j.msec.2015.04.033] [Citation(s) in RCA: 146] [Impact Index Per Article: 16.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/29/2014] [Revised: 02/17/2015] [Accepted: 04/21/2015] [Indexed: 10/23/2022]
|
62
|
Kim DG, Jeong YH, Kosel E, Agnew AM, McComb DW, Bodnyk K, Hart RT, Kim MK, Han SY, Johnston WM. Regional variation of bone tissue properties at the human mandibular condyle. Bone 2015; 77:98-106. [PMID: 25913634 PMCID: PMC4447536 DOI: 10.1016/j.bone.2015.04.024] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/07/2014] [Revised: 04/03/2015] [Accepted: 04/15/2015] [Indexed: 10/23/2022]
Abstract
The temporomandibular joint (TMJ) bears different types of static and dynamic loading during occlusion and mastication. As such, characteristics of mandibular condylar bone tissue play an important role in determining the mechanical stability of the TMJ under the macro-level loading. Thus, the objective of this study was to examine regional variation of the elastic, plastic, and viscoelastic mechanical properties of human mandibular condylar bone tissue using nanoindentation. Cortical and trabecular bone were dissected from mandibular condyles of human cadavers (9 males, 54-96 years). These specimens were scanned using microcomputed tomography to obtain bone tissue mineral distribution. Then, nanoindentation was conducted on the surface of the same specimens in hydration. Plastic hardness (H) at a peak load, viscoelastic creep (Creep/Pmax), viscosity (η), and tangent delta (tan δ) during a 30 second hold period, and elastic modulus (E) during unloading were obtained by a cycle of indentation at the same site of bone tissue. The tissue mineral and nanoindentation parameters were analyzed for the periosteal and endosteal cortex, and trabecular bone regions of the mandibular condyle. The more mineralized periosteal cortex had higher mean values of elastic modulus, plastic hardness, and viscosity but lower viscoelastic creep and tan δ than the less mineralized trabecular bone of the mandibular condyle. These characteristics of bone tissue suggest that the periosteal cortex tissue may have more effective properties to resist elastic, plastic, and viscoelastic deformation under static loading, and the trabecular bone tissue to absorb and dissipate time-dependent viscoelastic loading energy at the TMJ during static occlusion and dynamic mastication.
Collapse
|
63
|
Perikamana SKM, Lee J, Ahmad T, Jeong Y, Kim DG, Kim K, Shin H. Effects of Immobilized BMP-2 and Nanofiber Morphology on In Vitro Osteogenic Differentiation of hMSCs and In Vivo Collagen Assembly of Regenerated Bone. ACS APPLIED MATERIALS & INTERFACES 2015; 7:8798-808. [PMID: 25823598 DOI: 10.1021/acsami.5b01340] [Citation(s) in RCA: 46] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
Engineering bone tissue is particularly challenging because of the distinctive structural features of bone within a complex biochemical environment. In the present study, we fabricated poly(L-lactic acid) (PLLA) electrospun nanofibers with random and aligned morphology immobilized with bone morphogenic protein-2 (BMP-2) and investigated how these signals modulate (1) in vitro osteogenic differentiation of human mesenchymal stem cells (hMSCs) and (2) in vivo bone growth rate, mechanical properties, and collagen assembly of newly formed bone. The orientation of adherent cells followed the underlying nanofiber morphology; however, nanofiber alignment did not show any difference in alkaline phosphate activity or in calcium mineralization of hMSCs after 14 days of in vitro culture in osteogenic differentiation media. In vivo bone regeneration was significantly higher in the nanofiber implanted groups (approximately 65-79%) as compared to the defect-only group (11.8 ± 0.2%), while no significant difference in bone regeneration was observed between random and aligned groups. However, nanoindentation studies of regenerated bone revealed Young's modulus and contact hardness with anisotropic feature for aligned group as compared to random group. More importantly, structural analysis of collagen at de novo bone showed the ability of nanofiber morphology to guide collagen deposition. SEM and TEM images revealed regular, highly ordered collagen assemblies on aligned nanofibers as compared to random fibers, which showed irregular, randomly organized collagen deposition. Taken together, we conclude that nanofibers in the presence of osteoinductive signals are a potent tool for bone regeneration, and nanofiber alignment can be used for engineering bone tissues with structurally assembled collagen fibers with defined direction.
Collapse
|
64
|
Kim DG, Kwon HJ, Jeong YH, Chien HH, Crance S, Agnew AM, Battula S, Lee JW, Wen HB. Associations of Resonance Frequency Analysis with Dynamic Mechanical Analysis of Dental Implant Systems. Clin Implant Dent Relat Res 2015; 18:332-41. [PMID: 25810026 DOI: 10.1111/cid.12319] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
BACKGROUND Resonance frequency analysis (RFA) has been introduced as a noninvasive method to clinically estimate the stability of dental implant systems. PURPOSE The objective of this study was to examine whether implant stability quotient (ISQ) values of RFA can account for mechanical stability of the dental implant system, which is assessed using dynamic mechanical analysis (DMA). MATERIALS AND METHODS Fifty-seven screw-type titanium dental implants were placed in artificial polyurethane foams with seven different thicknesses (3.5 to 12 mm) and eight edentulous mandibles of human cadavers (four men and four women, 79.11 ± 13.48 years). After the ISQ values, insertion torque, and static stiffness of each implant system were measured, the DMA was performed to assess dynamic stiffness and viscoelastic tan δ. RESULTS The ISQ value had strong positive correlations with thickness, insertion torque, static and dynamic stiffness, and a negative correlation with tan δ of implant systems in artificial bone blocks (r = 0.769 to 0.992, p < .043). However, the ISQ value was correlated with only the insertion torque of implant systems in human mandibles (p < .049). CONCLUSION The ISQ values could reflect mechanical stability of the dental implant system under the controlled condition of homogeneous density in simple dimensions.
Collapse
|
65
|
Crawford B, Kim DG, Moon ES, Johnson E, Fields HW, Palomo JM, Johnston WM. Cervical vertebral bone mineral density changes in adolescents during orthodontic treatment. Am J Orthod Dentofacial Orthop 2014; 146:183-9. [PMID: 25085301 DOI: 10.1016/j.ajodo.2014.04.019] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2013] [Revised: 04/01/2014] [Accepted: 04/01/2014] [Indexed: 10/25/2022]
Abstract
INTRODUCTION The cervical vertebral maturation (CVM) stages have been used to estimate facial growth status. In this study, we examined whether cone-beam computed tomography images can be used to detect changes of CVM-related parameters and bone mineral density distribution in adolescents during orthodontic treatment. METHODS Eighty-two cone-beam computed tomography images were obtained from 41 patients before (14.47 ± 1.42 years) and after (16.15 ± 1.38 years) orthodontic treatment. Two cervical vertebral bodies (C2 and C3) were digitally isolated from each image, and their volumes, means, and standard deviations of gray-level histograms were measured. The CVM stages and mandibular lengths were also estimated after converting the cone-beam computed tomography images. RESULTS Significant changes for the examined variables were detected during the observation period (P ≤0.018) except for C3 vertebral body volume (P = 0.210). The changes of CVM stage had significant positive correlations with those of vertebral body volume (P ≤0.021). The change of the standard deviation of bone mineral density (variability) showed significant correlations with those of vertebral body volume and mandibular length for C2 (P ≤0.029). CONCLUSIONS The means and variability of the gray levels account for bone mineral density and active remodeling, respectively. Our results indicate that bone mineral density distribution and the volume of the cervical vertebral body changed because of active bone remodeling during maturation.
Collapse
|
66
|
Kim DG, Jeong K, Ko SO. Removal of road deposited sediments by sweeping and its contribution to highway runoff quality in Korea. ENVIRONMENTAL TECHNOLOGY 2014; 35:2546-55. [PMID: 25145210 DOI: 10.1080/09593330.2014.911777] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
Highway runoff is known to be an important non-point source (NPS), increasing the load of pollutants in receiving water. For reducing NPS pollutants in runoff, removal of road deposited sediment (RDS) by sweeping is considered effective. However, the contribution of sweeping to the improvement of runoff quality has not been clearly and quantitatively demonstrated so far. In this study, a field test was carried out on a section of operating highway in Korea to investigate the effectiveness of sweeping on improving the quality of highway runoff. Results showed that the average reduction in the load of RDS by sweeping was 61.10% with a standard deviation of 1.74%. RDS removal efficiency decreased when the sweeping speed increased from 4-8 to 20 km h(-1), the load decreased from 12.5 to 1.25 g m(-2) and particle size decreased from sand to silt/clay size ranges. Runoff was induced by applying a 15 mm h(-1) artificial rainfall to both swept and non-swept sections. Analysis of runoff quality showed that the event mean concentrations of total suspended solid, biological oxygen demand, chemical oxygen demand, nutrients and most of the heavy metals were reduced by 31-87% after sweeping. In addition, field tests for RDS build-up indicated a sweeping frequency of once every four or five days to prevent re-suspension of RDS. The results of this study suggest that sweeping can be the best management practice for effectively reducing RDS on highways and improving the quality of highway runoff.
Collapse
|
67
|
Hong MH, Kim YH, Ganbat D, Kim DG, Bae CS, Oh DS. Capillary action: enrichment of retention and habitation of cells via micro-channeled scaffolds for massive bone defect regeneration. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2014; 25:1991-2001. [PMID: 24796626 DOI: 10.1007/s10856-014-5225-1] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/09/2014] [Accepted: 04/21/2014] [Indexed: 06/03/2023]
Abstract
The development of a biomaterial substitute that can promote bone regeneration in massive defects has remained as a significant clinical challenge even using bone marrow cells or growth factors. Without an active, thriving cell population present throughout and stable anchored to the construct, exceptional bone regeneration does not occur. An engineered micro-channel structures scaffold within each trabecular has been designed to overcome some current limitations involving the cultivation and habitation of cells in large, volumetric scaffolds to repair massive skeletal defect. We created a scaffold with a superior fluid retention capacity that also may absorb bone marrow cells and provide growth factor-containing body fluids such as blood clots and/or serum under physiological conditions. The scaffold is composed of 3 basic structures (1) porous trabecular network (300-400 μm) similar to that of human trabecular bones, (2) micro-size channels (25-70 μm) within each trabecular septum which mimic intra-osseous channels such as Haversian canals and Volkmann's canals with body fluid access, diffusion, nutritional supply and gas exchange, and (3) nano-size pores (100-400 nm) on the surface of each septum that allow immobilized cells to anchor. Combinatorial effects of these internal structures result in a host-adapting construct that enhances cell retention and habitation throughout the 3 cm-height and 4 cm-length bridge-shaped scaffold.
Collapse
|
68
|
Kim DG. Can dental cone beam computed tomography assess bone mineral density? J Bone Metab 2014; 21:117-26. [PMID: 25006568 PMCID: PMC4075265 DOI: 10.11005/jbm.2014.21.2.117] [Citation(s) in RCA: 52] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/03/2014] [Revised: 05/18/2014] [Accepted: 05/18/2014] [Indexed: 12/02/2022] Open
Abstract
Mineral density distribution of bone tissue is altered by active bone modeling and remodeling due to bone complications including bone disease and implantation surgery. Clinical cone beam computed tomography (CBCT) has been examined whether it can assess oral bone mineral density (BMD) in patient. It has been indicated that CBCT has disadvantages of higher noise and lower contrast than conventional medical computed tomography (CT) systems. On the other hand, it has advantages of a relatively lower cost and radiation dose but higher spatial resolution. However, the reliability of CBCT based mineral density measurement has not yet been fully validated. Thus, the objectives of this review are to discuss 1) why assessment of BMD distribution is important and 2) whether the clinical CBCT can be used as a potential tool to measure the BMD. Brief descriptions of image artefacts associated with assessment of gray value, which has been used to account for mineral density, in CBCT images are provided. Techniques to correct local and conversion errors in obtaining the gray values in CBCT images are also introduced. This review can be used as a quick reference for users who may encounter these errors during analysis of CBCT images.
Collapse
|
69
|
Sun Z, Tee BC, Kennedy KS, Kennedy PM, Kim DG, Mallery SR, Fields HW. Scaffold-based delivery of autologous mesenchymal stem cells for mandibular distraction osteogenesis: preliminary studies in a porcine model. PLoS One 2013; 8:e74672. [PMID: 24040314 PMCID: PMC3764039 DOI: 10.1371/journal.pone.0074672] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2013] [Accepted: 08/02/2013] [Indexed: 01/12/2023] Open
Abstract
Purpose Bone regeneration through distraction osteogenesis (DO) is promising but remarkably slow. To accelerate it, autologous mesenchymal stem cells have been directly injected to the distraction site in a few recent studies. Compared to direct injection, a scaffold-based method can provide earlier cell delivery with potentially better controlled cell distribution and retention. This pilot project investigated a scaffold-based cell-delivery approach in a porcine mandibular DO model. Materials and Methods Eleven adolescent domestic pigs were used for two major sets of studies. The in-vitro set established methodologies to: aspirate bone marrow from the tibia; isolate, characterize and expand bone marrow-derived mesenchymal stem cells (BM-MSCs); enhance BM-MSC osteogenic differentiation using FGF-2; and confirm cell integration with a gelatin-based Gelfoam scaffold. The in-vivo set transplanted autologous stem cells into the mandibular distraction sites using Gelfoam scaffolds; completed a standard DO-course and assessed bone regeneration by macroscopic, radiographic and histological methods. Repeated-measure ANOVAs and t-tests were used for statistical analyses. Results From aspirated bone marrow, multi-potent, heterogeneous BM-MSCs purified from hematopoietic stem cell contamination were obtained. FGF-2 significantly enhanced pig BM-MSC osteogenic differentiation and proliferation, with 5 ng/ml determined as the optimal dosage. Pig BM-MSCs integrated readily with Gelfoam and maintained viability and proliferative ability. After integration with Gelfoam scaffolds, 2.4–5.8×107 autologous BM-MSCs (undifferentiated or differentiated) were transplanted to each experimental DO site. Among 8 evaluable DO sites included in the final analyses, the experimental DO sites demonstrated less interfragmentary mobility, more advanced gap obliteration, higher mineral content and faster mineral apposition than the control sites, and all transplanted scaffolds were completely degraded. Conclusion It is technically feasible and biologically sound to deliver autologous BM-MSCs to the distraction site immediately after osteotomy using a Gelfoam scaffold to enhance mandibular DO.
Collapse
|
70
|
Kim DG, Moon W, Lim CS. Varicella zoster gastritis in an immunocompetent adult woman. Endoscopy 2013; 44 Suppl 2 UCTN:E381-2. [PMID: 23139032 DOI: 10.1055/s-0032-1310035] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/10/2022]
|
71
|
Wood R, Sun Z, Chaudhry J, Tee BC, Kim DG, Leblebicioglu B, England G. Factors affecting the accuracy of buccal alveolar bone height measurements from cone-beam computed tomography images. Am J Orthod Dentofacial Orthop 2013; 143:353-63. [DOI: 10.1016/j.ajodo.2012.10.019] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2012] [Revised: 10/01/2012] [Accepted: 10/01/2012] [Indexed: 11/27/2022]
|
72
|
Leblebicioglu B, Salas M, Ort Y, Johnson A, Yildiz VO, Kim DG, Agarwal S, Tatakis DN. Determinants of alveolar ridge preservation differ by anatomic location. J Clin Periodontol 2013; 40:387-95. [PMID: 23432761 DOI: 10.1111/jcpe.12065] [Citation(s) in RCA: 38] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2012] [Revised: 10/30/2012] [Accepted: 12/27/2012] [Indexed: 11/28/2022]
Abstract
AIM To investigate and compare outcomes following alveolar ridge preservation (ARP) in posterior maxilla and mandible. METHODS Twenty-four patients (54 ± 3 years) with single posterior tooth extraction were included. ARP was performed with freeze-dried bone allograft and collagen membrane. Clinical parameters were recorded at extraction and re-entry. Harvested bone cores were analysed by microcomputed tomography (micro-CT), histomorphometry and immunohistochemistry. RESULTS In both jaws, ARP prevented ridge height loss, but ridge width was significantly reduced by approximately 2.5 mm. Healing time, initial clinical attachment loss and amount of keratinized tissue at extraction site were identified as determinants of ridge height outcome. Buccal plate thickness and tooth root length were identified as determinants of ridge width outcome. In addition, initial ridge width was positively correlated with ridge width loss. Micro-CT revealed greater mineralization per unit volume in new bone compared with existing bone in mandible (p < 0.001). Distributions of residual graft, new cellular bone and immature tissue were similar in both jaws. CONCLUSION Within the limitations of this study, the results indicate that in different anatomic locations different factors may determine ARP outcomes. Further studies are needed to better understand determinants of ARP outcomes.
Collapse
|
73
|
Kennedy KS, Jones EM, Kim DG, McGlumphy EA, Clelland NL. A Prospective Clinical Study to Evaluate Early Success of Short Implants. Int J Oral Maxillofac Implants 2013; 28:170-7. [DOI: 10.11607/jomi.2810] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
|
74
|
Kim DG, Huja SS, Navalgund A, D'Atri A, Tee B, Reeder S, Lee HR. Effect of estrogen deficiency on regional variation of a viscoelastic tissue property of bone. J Biomech 2012; 46:110-5. [PMID: 23141522 DOI: 10.1016/j.jbiomech.2012.10.013] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2012] [Revised: 09/27/2012] [Accepted: 10/12/2012] [Indexed: 10/27/2022]
Abstract
Estrogen deficiency changes the regional distribution of tissue mineral density leading to alteration of the mechanical properties of bone at the tissue level. Direct measurement of the regional variation of elastic modulus and viscosity, which is the capacity to resist time-dependent viscoelastic deformation, will aid in our understanding of how estrogen deficiency alters bone quality. It was observed that, compared to bone from other anatomical sites, the jaw bone is less sensitive to estrogen deficiency. Thus, the objective of this study was to examine the effect of estrogen deficiency on (1) the regional variations of tissue modulus and viscosity of bone using nanoindentation, and (2) the modulus-viscosity relationships in jaw and vertebral bones for comparison between different anatomical sites. Mandibular and vertebral bone specimens of sham surgery and ovariectomized (OVX) rat groups were subject to nanoindentation in hydration. Indentation modulus and viscosity were measured at relatively new (less mineralized) tissue regions and at the corresponding pre-existing old (more mineralized) tissue regions of mandibular and vertebral bones. In the mandibular bones, significant regional variations of indentation modulus and viscosity were observed (p<0.039) and OVX increased the indentation viscosity. While significant positive correlations were found between indentation modulus and viscosity (p<0.001), the correlation slopes for the mandibular and vertebral bones were significant different (p<0.001). The current results indicated that changes in viscoelastic property and its regional variation should be examined to obtain a better understanding of estrogen deficiency-dependent alteration of bone quality.
Collapse
|
75
|
Kim DG, Navalgund AR, Tee BC, Noble GJ, Hart RT, Lee HR. Increased variability of bone tissue mineral density resulting from estrogen deficiency influences creep behavior in a rat vertebral body. Bone 2012; 51:868-75. [PMID: 22944606 PMCID: PMC3455132 DOI: 10.1016/j.bone.2012.08.124] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/07/2012] [Revised: 07/17/2012] [Accepted: 08/20/2012] [Indexed: 11/21/2022]
Abstract
Progressive vertebral deformation increases the fracture risk of a vertebral body in the postmenopausal patient. Many studies have observed that bone can demonstrate creep behavior, defined as continued time-dependent deformation even when mechanical loading is held constant. Creep is a characteristic of viscoelastic behavior, which is common in biological materials. We hypothesized that estrogen deficiency-dependent alteration of the mineral distribution of bone at the tissue level could influence the progressive postmenopausal vertebral deformity that is observed as the creep response at the organ level. The objective of this study was thus to examine whether the creep behavior of vertebral bone is changed by estrogen deficiency, and to determine which bone property parameters are responsible for the creep response of vertebral bone at physiological loading levels using an ovariectomized (OVX) rat model. Correlations of creep parameters with bone mineral density (BMD), tissue mineral density (TMD) and architectural parameters of both OVX and sham surgery vertebral bone were tested. As the vertebral creep was not fully recovered during the post-creep unloading period, there was substantial residual displacement for both the sham and OVX groups. A strong positive correlation between loading creep and residual displacement was found (r=0.868, p<0.001). Of the various parameters studied, TMD variability was the parameter that best predicted the creep behavior of the OVX group (p<0.038). The current results indicated that creep caused progressive, permanent reduction in vertebral height for both the sham and OVX groups. In addition, estrogen deficiency-induced active bone remodeling increased variability of trabecular TMD in the OVX group. Taken together, these results suggest that increased variability of trabecular TMD resulting from high bone turnover influences creep behavior of the OVX vertebrae.
Collapse
|