51
|
Stachel DK, Leipold A, Krapf T, Knüfer V, Ringwald J, Strasser E, Zingsem J, Beck JD, Holter W. Successful stem cell mobilization with stem cell factor and granulocyte colony-stimulating factor in patients with solid tumors failing conventional mobilization with chemotherapy and G-CSF. JOURNAL OF HEMATOTHERAPY & STEM CELL RESEARCH 2003; 12:131-3. [PMID: 12804171 DOI: 10.1089/152581603321628269] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
52
|
Glaser A, Friedlein H, Zingsem J, Zimmermann R, Weisbach V, Ruf A, Eckstein R. Storage of single donor platelet concentrates: paired comparison of storage as single or double concentrates. J Clin Apher 2003; 16:148-54. [PMID: 11746543 DOI: 10.1002/jca.1028] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Modern cell separators allow the collection of two plateletpheresis concentrates (PCs) at one session. This study evaluates the quality of PCs stored as double concentrates in standard storage containers of two manufacturers. We collected 20 PCs that contained 4.5 x 10(11) platelets in 375 ml plasma (10 using the COBE Spectra and 10 using the Fresenius AS.TEC 204 with 500 ml bags) that were split into one unit of 3.0 x 10(11) platelets in 250 ml (3.0-PC) and one of 1.5 x 10(11) platelets in 125 ml (1.5-PC). Storage of one 3.0-PC per bag of a two-bag system corresponded to storage conditions for double PCs and storage of one 1.5-PC per bag to storage conditions of single PCs. Cell counts, blood gas analysis, glucose and lactate levels, platelet aggregation, and activation and plasma levels of beta- thromboglobulin (beta-TG) and complement factor 3a (C3a) were measured before storage and again on days 3 and 5. COBE 3.0-PCs demonstrated less pH rise, lactate production, CD 62P expression and beta-TG plasma levels, and better aggregability after storage than COBE 1.5-PCs. Fresenius 1.5-PCs had similar platelet quality to COBE 3.0-PCs. Fresenius 3.0-PCs showed a fall of pH (day 5: 6.22 +/- 0.56), the highest amount of anaerobic glycolysis compared to all other storage conditions investigated, high CD 62P- expression and beta-TG plasma levels, and impaired aggregability on days 3 and 5. The highest C3a levels were found in COBE 1.5-PCs. 3.0 x 10(11) platelets in 250 ml plasma should be stored either in one bag of the COBE system or in two 500 ml bags of the Fresenius system. The COBE two-bag system allows the storage of two PCs without loss of platelet quality. Two PCs should not be stored in the Fresenius C4L 500 ml storage containers.
Collapse
|
53
|
Zingsem J, Weisbach V, Zimmermann R, Glaser A, Bunkens H, Eckstein R. Preparation of FFP as a by-product of plateletpheresis. Transfusion 2002; 42:81-6. [PMID: 11896317 DOI: 10.1046/j.1537-2995.2002.00025.x] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
BACKGROUND To reduce the production costs of single-donor platelets (SDPs), a study was conducted to investigate whether plasma collected as a by-product of plateletpheresis satisfies the quality requirements for FFP without impairing the quality of the SDP component. STUDY DESIGN AND METHODS Ninety-two donors with platelet (PLT) counts <270 x 10(9) per L underwent plateletpheresis using an automated cell separator (Spectra Apheresis System with the Leukoreduction System [LRS], Gambro BCT, Lakewood, CO). The machine was programmed to collect 3 x 10(11) PLTs in 250 mL of plasma with an additional unit of 350 mL of plasma or 3 x 10(11) PLTs in 250 mL of plasma without additional plasma in 10 procedures. FV and FVIII and residual RBCs, WBCs, and PLTs in the plasma were measured for quality control. RESULTS FV was 0.87 +/- 0.18 IU per mL, and FVIII was 1.32 +/- 0.48 IU per mL in the plasma components (n = 41). The recovery was 94.1 +/- 5.5 percent for FV and 102.2 +/- 9.5 percent for FVIII when compared with the donors' predonation values. Residual cells were 0.002 +/- 0.009 x 10(9) RBCs per L (n = 30), 12 +/- 6 x 10(9) PLTs per L (n = 30), and 0.32 +/- 0.37 x 10(6) WBCs per L (n = 92). CONCLUSIONS Using the automated cell separator and special software, it is possible to collect plasma as a by-product of plateletpheresis that meets the properties requested for FFP without impairing the quality of the SDP components. The content of clotting factors is within the requested range for FFP. Residual cell counts are within all European and U.S. specifications for FFP, and the WBC content even satisfies the criteria for WBC-reduced blood components. The collection of FFP as a by-product does not cause any additional costs and thus helps to reduce the costs in preparing blood components.
Collapse
|
54
|
Zingsem J, Glaser A, Zimmermann R, Weisbach V, Kalb R, Ruf A, Eckstein R. Paired comparison of apheresis platelet function after storage in two containers. J Clin Apher 2001; 16:10-4. [PMID: 11309824 DOI: 10.1002/jca.1001] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Platelet quality after storage strongly depends on the pre-storage quality as well as on the storage conditions determined by the storage container. In this paired study, we evaluated two different containers (MedSep CLX and Delmed DPL-110). The Fresenius AS104 cell separator was used to prepare 17 platelet concentrates that were split and distributed into the containers to be compared. Cell counts, blood gas analysis, morphological scores, glucose and lactate levels, platelet activation, and platelet aggregation were measured before splitting at the day of preparation and after storage at day 3 and day 5. At day 3, there was no significant difference between the two bags apart from increased lactate and decreased pCO(2) concentrations in the CLX bags. At day 5 there were significantly higher lactate concentrations, pO(2) levels, and aggregation after stimulation in the CLX group, while the glucose and pCO(2) concentrations were significantly lower in these platelet concentrates as compared to the DPL-110 group. However, these parameters did not influence the functional parameters tested. While the platelet quality decreased during storage in all bags, the functional changes were nearly identical in both bags tested. We conclude that both bags are equivalent for 5-day storage of platelet concentrates.
Collapse
|
55
|
Zingsem J, Zimmermann R, Weisbach V, Glaser A, Bunkens H, Eckstein R. Comparison of a new WBC-reduction system and the standard plateletpheresis protocol in the same donors. Transfusion 2001; 41:396-400. [PMID: 11274597 DOI: 10.1046/j.1537-2995.2001.41030396.x] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
BACKGROUND A cell separator (Spectra, Gambro BCT) with an integrated leukoreduction system (LRS) for producing WBC-reduced single-donor platelet concentrates has been shown to result in a slightly reduced collection efficiency as compared to the former Spectra system without LRS. A novel modified system for improved collection efficiencies (LRS Turbo, Gambro BCT) was evaluated. STUDY DESIGN AND METHODS Each of 37 donors underwent plateletpheresis using the LRS Turbo (LRS-T) and the standard LRS (LRS) of the Spectra cell separator. The collection efficiency and WBC contamination of the different techniques were compared. Platelets were counted automatically and WBCs were counted by using one or two full grids of a Nageotte chamber. RESULTS The preseparation and postseparation numbers of RBCs, WBCs, and platelets, as well as the number of collected platelets, did not differ for the two techniques. In the LRS-T separations, the collection efficiency was 112 percent of that in the LRS procedures. Median residual WBCs in the platelet components were 0.0256 x 10(6) per LRS-T procedure and 0.0253 x 10(6) per LRS procedure. The purity of the LRS-T components was not less than that of the standard LRS components, whereas the collection efficiency of the LRS-T was significantly greater, 44.9 percent versus 40.7 percent. CONCLUSIONS The LRS-T procedures produced platelet concentrates with WBC-reduction capacity that is comparable to that obtained with the standard LRS procedures, which have previously been described as satisfying the most stringent criteria for WBC-reduced platelets. The new technique significantly improved the collection efficiency of the plateletpheresis procedure.
Collapse
|
56
|
Zimmermann R, Schmidt S, Zingsem J, Glaser A, Weisbach V, Ruf A, Eckstein R. Effect of gamma radiation on the in vitro aggregability of WBC-reduced apheresis platelets. Transfusion 2001; 41:236-42. [PMID: 11239229 DOI: 10.1046/j.1537-2995.2001.41020236.x] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
BACKGROUND The effect of gamma radiation on single-donor apheresis platelet concentrates (SDPs) has been elucidated only incompletely. The only existing report on the function of SDPs stored in the irradiated state found a deterioration in the in vitro aggregability at the end of shelf life in SDPs divided before irradiation with 1500 cGy. STUDY DESIGN AND METHODS The in vitro properties of platelets were examined in four series of irradiated and control platelets, each obtained from the same 15 donors. Irradiation with 3000 cGy was performed on Days 0, 3, and 5. Cellular content, aggregability by ADP alone or ADP and epinephrine, spontaneous and induced CD62 expression, beta-thromboglobulin release, glucose consumption, lactate production, and pH were measured immediately after preparation and on Days 3 and 5 after donation. RESULTS Comparable in vitro properties were measured in irradiated and control platelets, whether irradiation was performed on Day 3 or Day 5. However, in platelets irradiated on Day 0, we found a significantly better in vitro aggregability by 20 microM: ADP immediately after irradiation and by 10 microM: ADP and 2 microM: epinephrine at the end of shelf life than was found in the other groups (Day 5 results: Day 0 irradiation: 75 +/- 32%; Day 3 irradiation: 45 +/- 45%; Day 5 irradiation: 47 +/- 41%; control: 40 +/- 24%; p<0.05). CONCLUSION Gamma radiation had no adverse effect on platelet quality in extremely WBC-reduced SDPs. On the contrary, a slight, but significantly better in vitro aggregability was found in SDPs irradiated before storage than in platelets irradiated later during storage and in unirradiated platelets. This increased in vitro aggregability persisted until the end of shelf life.
Collapse
|
57
|
Weisbach V, Corbière C, Strasser E, Zingsem J, Zimmermann R, Eckstein R. The variability of compensatory erythropoiesis in repeated autologous blood donation. Transfusion 2001; 41:179-83. [PMID: 11239219 DOI: 10.1046/j.1537-2995.2001.41020179.x] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
BACKGROUND Compensatory RBC production during repeated preoperative autologous blood donation (PABD) shows marked interindividual variability. This study was performed to reveal variables that might be useful to predict the amount of the erythropoietic response to PABD in an individual patient who was not iron deficient. STUDY DESIGN AND METHODS In a retrospective study, 104 adult patients, 48 women and 56 men (mean age, 59.9 years; range, 18-82 years) who donated 3 units (450 mL) of autologous blood at weekly intervals for major surgery were investigated. Blood counts, ferritin, and net preoperative RBC production (net RBC production) were determined in all patients, and soluble transferrin receptor and endogenous levels of EPO, SCF, and IL-1beta were measured in 63 patients. Multiple linear regression analysis was used to determine whether the variance of net RBC production was attributable to baseline values of these variables. RESULTS Net RBC production was not different in patients who received oral iron and patients who did not (384 +/- 222 mL vs. 356 +/- 158 mL). In both groups, the same two variables consistently showed a significant relationship to net RBC production: the length of the period between the third donation and the last visit was positively related (p = 0.00001 vs. p = 0.0002) and the Hct at baseline was negatively related (p = 0.0002 vs. p = 0.02) with net RBC production. The proportion of variance in net RBC production that was attributable to these two variables was 48.1 percent (r(2) = 0.481) and 34.9 percent (r(2) = 0.349), respectively. CONCLUSION RBC production after PABD increases with increasing interval from last donation to surgery. This suggests that the interval from last donation to surgery should be maximized. This can be achieved by organizational measures in combination with the preparation of RBC concentrates in additive solution with a maximum shelf life.
Collapse
|
58
|
Glaser A, Schuler-Thurner B, Feuerstein B, Zingsem J, Zimmermann R, Weisbach V, Eckstein R. Collection of MNCs with two cell separators for adoptive immunotherapy in patients with stage IV melanoma. Transfusion 2001; 41:117-22. [PMID: 11161256 DOI: 10.1046/j.1537-2995.2001.41010117.x] [Citation(s) in RCA: 21] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
BACKGROUND MNCs for adoptive immunotherapy may be collected by leukocytapheresis with a cell separator. STUDY DESIGN AND METHODS Six healthy cytapheresis donors donated two MNC concentrates on a cell separator (AS.TEC 204, Fresenius): one on the standard MNC program and one on a modified MNC program with reduced centrifuge velocity that leads to a lower platelet contamination. Seventeen patients with malignant melanoma donated 26 MNC concentrates: 5 on the AS.TEC 204 MNC program, 9 on the modified AS.TEC 204 MNC program, and 12 on another modified MNC program (Spectra, COBE). RESULTS In the course of cultivation of MNCs to dendritic cells (DCs), the donor MNC concentrates with the lower platelet contamination (475 +/- 85 x 10(9)/L) had a significantly higher relative DC yield (low platelet contamination: 3.9 +/- 1.6% of the plated cells; high platelet contamination: 2.5 +/- 1.8% of the plated cells; p = 0.019) than the concentrates with the higher platelet contamination (2364 +/- 448 x 10(9)/L). No significant difference was found in the yields of MNCs and CD14+ cells in the three protocols used for the collection of MNCs from patients with melanoma. The components obtained by the standard AS.TEC 204 MNC program had a significantly higher platelet contamination (1768 +/- 994 x 10(9)/L) than the components obtained by the modified AS.TEC MNC program (360 +/- 98 x 10(9)/L; p<0.05) and the modified Spectra MNC program (636 +/- 266 x 10(9)/L); p<0.05). Because of the low number of investigated components, no significant difference in the DC yield of the three protocols could be detected (mean DC yield after cultivation: 746 +/- 429 x 10(6)). CONCLUSION A high platelet contamination of MNC concentrates intended for adoptive immunotherapy can lead to a significant impairment of the DC yield after cultivation. Both the modified AS.TEC 204 and the modified Spectra MNC programs are well suited for collecting MNC concentrates with high MNC yields and low platelet contamination from patients with malignant melanoma.
Collapse
|
59
|
Rick O, Beyer J, Kingreen D, Kühl JS, Zingsem J, Huhn D, Siegert W, Schwella N. Successful autologous bone marrow rescue in patients who failed peripheral blood stem cell mobilization. Ann Hematol 2000; 79:681-6. [PMID: 11195005 DOI: 10.1007/s002770000215] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
We assessed autologous bone marrow (BM) harvest and hematologic recovery after high-dose chemotherapy (HDCT) in patients who failed to achieve peripheral blood stem cell (PBSC) mobilization. One hundred and ninety-three patients with germ cell tumor, malignant lymphoma, sarcoma or medulloblastoma were scheduled for HDCT. In 123 patients, PBSC were mobilized by disease-specific chemotherapy plus granulocyte colony-stimulating factor (G-CSF). In 110/ 123 patients (89%) with circulating CD34+ cell counts 2 > or = 10/microl, sufficient hematopoietic autografts were collected (group A). In 13/123 patients (11%) with peripheral CD34 + cell counts < 10/microl, PBSC harvesting was not performed (group B). These latter patients were classified as "poor mobilizers" and underwent second-line BM harvest at a median of 46 (range 10-99) days after mobilization failure. Seventy patients with first-line BM harvest (group C) acted as historical controls. Ten patients from group B proceeded to HDCT and nine were evaluable for hematopoietic reconstitution. Recovery to neutrophils >0.5 x 10(9)/l was comparable with group C patients: 16 (range 9-34) days vs 13 (range 8-98) days. However, platelet (PLT) reconstitution >20 x 10(9)/l was significantly slower, with a median of 35 (range 13-50) days as compared with 19 (range 9-148) days (P = 0.0106) for control patients. Supportive care requirements, febrile days and length of hospital stay were not significantly different between the two groups of patients. We conclude that patients who fail to mobilize PBSC should be evaluated for second-line BM harvest. This approach may preserve the therapeutic option of HDCT for these patients.
Collapse
|
60
|
Schwella N, Rick O, Heuft HG, Miksits K, Zimmermann R, Zingsem J, Eckstein R, Huhn D. Bacterial contamination of autologous bone marrow: reinfusion of culture-positive grafts does not result in clinical sequelae during the posttransplantation course. Vox Sang 2000; 74:88-94. [PMID: 9501406] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
OBJECTIVES Microbiological cultures and posttransplantation course were analyzed in order to investigate the incidence and clinical significance of bacterial contamination of autologous bone marrow (BM) grafts. METHODS Cultures were obtained from BM after collection, BM concentrate after processing, contaminated/cryopreserved BM at thawing, and from peripheral blood (PB) following autologous BM transplantation (ABMT). The posttransplantation course of patients grafted with culture-positive BM was recorded and compared with patients who underwent ABMT with noncontaminated BM grafts. RESULTS In 239 BM grafts processed, the incidence of microbiological contamination was 26.4% (n = 63). Fifty marrow grafts were contaminated by bacteria from the skin flora: coagulase-negative Staphylococcus (CNSC), Propionibacterium, and Corynebacterium species (79%). Thirty-eight patients underwent ABMT (day 0) with cryopreserved culture-positive BM, and 32 patients were evaluable for microbiological cultures at thawing: in 10 of 32 BM grafts CNSC was found prior to reinfusion. Following ABMT, PB cultures revealed CNSC in 5 of 38 patients between days +4 and +12. However, the late occurrence of positive PB cultures after BM reinfusion made a relationship between BM CNSC and PB CNSC unlikely. In 33 of 38 patients, no graft-contaminating bacteria were detected in PB. Comparison of the posttransplantation course of patients who received contaminated BM with that of patients grafted with noncontaminated BM showed no significant differences concerning time to engraftment, febrile days, and days on antibiotics. CONCLUSION (1) Collection and/or ex vivo processing can result in microbiological contamination of BM grafts predominantly with bacteria from the skin flora, and (2) only CNSC can be cultured at thawing from previously contaminated/cryopreserved BM. Since patients undergoing ABMT usually receive oral antibiotics from beginning of the conditioning regimen which are active against CNSC, no further administration of antibiotics is recommended for the reinfusion of bacterially contaminated BM grafts.
Collapse
|
61
|
Zingsem J, Glaser A, Weisbach V, Zimmermann R, Neidhardt B, van Waeg G, Eckstein R. Evaluation of a platelet apheresis technique for the preparation of leukocyte-reduced platelet concentrates. Vox Sang 2000; 74:189-92. [PMID: 9595647] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
OBJECTIVES Reduction of the white blood cell (WBC) contamination in platelet concentrates (PC) protects patients from the immunological and infectious side effects of platelet transfusion caused by WBC. This can be done either by filtration of the PC or by improved apheresis techniques that yield WBC-poor preparations. METHODS To evaluate an improved technique for platelet collection, we carried out 201 separations in 89 healthy cytapheresis donors using the new COBE Spectra leukoreduction system (LRS) and compared the results with those of standard dual-needle separations obtained with the same cell separator. RESULTS A small but statistically significant difference was found in platelet collection efficiency in comparison with the standard non-LRS software procedures (LRS: 52.6 vs. 56.3% for the reference). However, median WBC contamination was only 0.01 x 10(6) WBC per LRS product. This significant (p < 0.0005) improvement corresponds to a 10-fold reduction of WBC as compared with the standard dual-needle technique. CONCLUSIONS The COBE Spectra LRS system produced PCs with a platelet collection efficiency nearly equal to previous techniques and with a residual WBC content satisfying even the most stringent criteria for WBC-depleted blood components. As this purity is achieved without important platelet loss, conventional fiber filtration no longer seems necessary in this kind of PC.
Collapse
|
62
|
Zeiler T, Zingsem J, Moog R, Kretschmer V, Eckstein R, Müller N, Eisenbeisz F. Periodic alternating interface positioning to lower WBC contamination of apheresis platelet concentrates: a multicenter evaluation. Transfusion 2000; 40:687-92. [PMID: 10864989 DOI: 10.1046/j.1537-2995.2000.40060687.x] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
BACKGROUND A new software version of a cell separator (AS TEC 204, Fresenius) providing WBC-reduced single-donor plateletpheresis concentrates was tested. STUDY DESIGN AND METHODS Dual-needle apheresis procedures (n = 621) were performed in three centers, using either fixed interface positioning (FIP) or periodic alternating interface positioning (PAIP). The other separation parameters (e.g., anticoagulant:whole-blood ratio, and blood flow) were set individually. All platelet concentrates were evaluated for platelet yields and contaminating WBCs. RESULTS The introduction of the PAIP resulted in a significant (p<0.001) reduction in contaminating WBCs (median, 30,000) from the numbers seen with FIP (median, 2,300,000) while maintaining the separation efficacy (47%) and separation time. Ninety-eight percent of all concentrates contained less than 5 x 10(6) WBCs per concentrate and 92 percent contained less than 1 x 10(6). CONCLUSION Plateletpheresis using the AS TEC 204 cell separator with PAIP is a valid alternative to WBC reduction by filtration. It may provide WBC-reduced platelet concentrates without the additional cost of filters. However, the reliability of the WBC reduction is not yet advanced enough that PAIP can be employed without any monitoring of the end product.
Collapse
|
63
|
Weisbach V, Hunold I, Zimmermann R, Lutter N, Parsch H, Zingsem J, Glaser A, Eckstein R. In vitro characteristics of red blood cell concentrates prepared from under- and overcollected units of whole blood and from a paediatric blood bag system. Transfus Med 2000; 10:23-30. [PMID: 10760200 DOI: 10.1046/j.1365-3148.2000.00228.x] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
The problem of how to deal with red blood cell concentrates (RBCs) prepared from under- or overcollected units of whole blood (WB) and how to collect blood from underweight persons arises in the context of autologous predeposit. To determine the quality of RBCs stored in PAGGS-M additive solution prepared from under- and overcollected units of whole blood and of PAGGS-M RBCs prepared from a paediatric 250-mL top outlet blood bag system we measured blood picture, haemolysis, K+, pH, ATP and 2,3-DPG on days 0, 10, 20, 30, 40 and 49 of storage. The volume of WB collected ranged from 150 to 600 mL in 50-mL increments (4 units per volume). Haemolysis was under 0.8% on day 49 in all RBCs prepared from WB donations between 200 mL and 600 mL. However, the day 49 haemolysis level of standard RBCs prepared from 450 mL of WB (0.15 +/- 0.03%) was reached earlier in RBCs from under- and overcollected units of whole blood. 2,3-DPG levels decreased rapidly between days 10 and 20 in all RBCs studied. RBCs from 450-mL donations showed acceptable ATP maintenance after 49 days (70.4% of day 0 value), while all other RBC ATP levels were below 50% of the day 0 level on day 49. In vitro quality data of RBCs prepared from a 250-mL donation in the paediatric blood bag system after storage for about 25 days were comparable to those after 49 days of storage of standard RBCs. Our results suggest that it is feasible to transfuse PAGGS-M RBCs prepared from under- as well as overcollected units of WB in the autologous setting. However, we strongly recommend shortening the storage period of such RBCs to maintain the quality level of standard RBCs.
Collapse
|
64
|
Weisbach V, Ziener A, Zimmermann R, Glaser A, Zingsem J, Eckstein R. Comparison of the performance of four microtube column agglutination systems in the detection of red cell alloantibodies. Transfusion 1999; 39:1045-50. [PMID: 10532596 DOI: 10.1046/j.1537-2995.1999.39101045.x] [Citation(s) in RCA: 38] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
BACKGROUND The purpose of this study was to compare the performance of four currently available microtube column agglutination systems in the detection of red cell alloantibodies to that of the standard tube low-ionic-strength solution (LISS) indirect antiglobulin test (IAT) (tube LISS-IAT). STUDY DESIGN AND METHODS In a comparative study, 172 sera, previously demonstrated to contain red cell alloantibodies, were tested in parallel by the tube LISS-IAT and three microtube column agglutination techniques (DiaMed-ID, Ortho BioVue, and Sanofi-Pasteur Scangel) and one affinity-adherence test system (Gamma ReACT). Tests were performed simultaneously by a single person on freshly thawed sera that had been frozen at -20 degrees C. RESULTS The rate of detection of clinically significant alloantibodies (n = 154) in microtube column systems was very similar. One hundred forty-one sera (91.6%) reacted in the DiaMed-ID, 139 (90.3%) in the ReACT, 139 (90.3%) in the BioVue, and 142 (92.2%) in the Scangel. Only 117 (76.0%) of these sera reacted in the tube LISS-IAT. The detection rates for 18 antibodies of minor clinical significance (anti-M, -N, -P1, -Le(a), and -Le(b)) varied among the test systems: DiaMed-ID, 5 (28%); ReACT, 7 (39%); BioVue, 14 (78%); Scangel, 10 (56%); and tube LISS-IAT, 6 (33%). Antibody reactivity as determined by titer and score was very similar in all microtube column systems and higher in these systems than in the tube LISS-IAT. CONCLUSION The sensitivity of all four microtube column systems in the detection of clinically significant red cell alloantibodies was similar and was markedly superior to that of the tube LISS-IAT. An individual cost-benefit analysis should be performed in every institution to decide whether a microtube column system should be applied. If so, the antibody screen in the microtube column agglutination system should ideally be performed in advance of the crossmatch to provide time to screen for compatible units.
Collapse
|
65
|
Weisbach V, Friedlein H, Glaser A, Zingsem J, Zimmermann R, Eckstein R. The influence of automated plateletpheresis on systemic levels of hematopoietic growth factors. Transfusion 1999; 39:889-94. [PMID: 10504126 DOI: 10.1046/j.1537-2995.1999.39080889.x] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
BACKGROUND Megakaryocytopoiesis and platelet production are regulated by several hematopoietic growth factors. The present study focuses on the effects of automated plateletpheresis on systemic levels of different hematopoietic growth factors. STUDY DESIGN AND METHODS Platelet count, mean platelet volume, and serum levels of thrombopoietin, erythropoietin, interleukin-1beta, interleukin-6, and stem cell factor in 21 healthy donors were measured before platelet collection, after the first half of the apheresis procedure, at the end of apheresis, and on Days 1, 2, and 7 thereafter. RESULTS Thrombopoietin levels (initial level: 49.5 +/- 25.5 pg/mL) showed a significant increase between measurements taken at the end of apheresis and Day 1 (56.9 +/- 26.7 pg/mL; p = 0.01). There was a highly significant decrease in stem cell factor levels during apheresis (p<0.0005), reaching preapheresis values (1679 +/- 210 pg/mL) on Day 1. A highly significant increase in erythropoietin levels (initial level: 7.5 +/- 4.0 U/L) was seen after apheresis (p<0.0005 on Days 1 and 2). The level remained significantly elevated until Day 7 (p = 0.004). Interleukin-1beta and interleukin-6 levels (before donation: 1.4 +/- 1.8 pg/mL and 1.1 +/- 0.7 pg/mL, respectively) did not change during the observation period. Thrombopoietin levels correlated consistently and inversely with stem cell factor levels after apheresis (Day 1, r = -0.46, p = 0.035; Day 2, r = -0.50, p = 0.02; Day 7, r = -0.50, p = 0.02). CONCLUSION The data show a coordinated response of the hematopoietic system to platelet loss. It is suggested that the decrease in serum stem cell factor levels during apheresis reflects the consumption of stem cell factor by early hematopoietic progenitors that expand to initiate early megakaryocytopoiesis. The temporary increase in thrombopoietin is the result of platelet loss and serves as a stimulus for subsequent thrombopoiesis. The pronounced elevation of erythropoietin after apheresis suggests a role for this primarily erythropoietic cytokine in thrombopoiesis, too.
Collapse
|
66
|
Zimmermann R, Wittmann G, Zingsem J, Blasczyk R, Weisbach V, Eckstein R. Antibodies to private and public HLA class I epitopes in platelet recipients. Transfusion 1999; 39:772-80. [PMID: 10413287 DOI: 10.1046/j.1537-2995.1999.39070772.x] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
BACKGROUND Transfusions or pregnancies can cause immunization against private HLA determinants and public epitopes shared by more than one private HLA antigen. HLA antibodies are correlated with febrile transfusion reactions, lower platelet response following platelet transfusion, and an increased rate of renal transplant rejection. Until now, antibody specificities in alloantisera from platelet recipients have been poorly characterized. STUDY DESIGN AND METHODS Consecutive serum screens from platelet recipients were analyzed for antibodies against private HLA class I antigens and public HLA epitopes using a serum analysis program based on the 2 x 2 table analysis of correlations. Serum screens of highly immunized patients and of patients with new alloimmunization events were reviewed separately. RESULTS Of the serum screens from 566 platelet recipients, 1577 indicated alloimmunization (panel-reactive antibodies >5%). The program assigned a specificity in 1024 of these screens (64.9%) and at least once in 522 of 566 patients (92.2%). In 267 patients, antibodies detecting public epitopes in the combined A- or B-locus cross-reacting groups were found; other public markers were detected in 39 patients. Patterns of reactivity were remarkably less stable than in patient groups previously studied. In many patients, antibodies with apparent private epitope specificity preceded the identification of antibodies against a shared marker of the same cross-reactive group. However, the disappearance of antibodies (whether or not this was followed by a new antibody against a private or public marker belonging to another cross-reacting group) was also observed. CONCLUSION The computerized analysis of microlymphocytotoxicity tests enhances the rate of antibody specification in sera from platelet recipients with lymphocytotoxic antibodies. The identified antibodies should be taken into account in the selection of platelet donors. The data confirm and extend previous observations on HLA class I antibodies and elucidate new alloimmunization events.
Collapse
|
67
|
Glaser A, Zingsem J, Zimmermann R, Weisbach V, Eckstein R. Collection of mononuclear cells in the Spectra for the generation of dendritic cells. Transfusion 1999; 39:661-2. [PMID: 10378850 DOI: 10.1046/j.1537-2995.1999.39060661.x] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
68
|
Weisbach V, Skoda P, Rippel R, Lauer G, Glaser A, Zingsem J, Zimmermann R, Eckstein R. Oral or intravenous iron as an adjuvant to autologous blood donation in elective surgery: a randomized, controlled study. Transfusion 1999; 39:465-72. [PMID: 10335995 DOI: 10.1046/j.1537-2995.1999.39050465.x] [Citation(s) in RCA: 45] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
BACKGROUND This study was performed to evaluate the capacity of oral and intravenous (i.v.) iron administration during autologous blood donation (ABD) to improve the efficacy of ABD and to prevent the need for allogeneic blood transfusion in patients without iron deficiency who are undergoing major elective surgery for which a minimum of 3 autologous units have been ordered. STUDY DESIGN AND METHODS One hundred twenty-three patients were enrolled in an open-labeled, randomized, controlled trial and assigned to three treatment groups: patients in Group 1 received 3 x 100 mg of Fe2+ per day given orally for 5 weeks before operation; patients in Group 2 received 200 mg of Fe3+ given intravenously after each donation combined with initial i.v. iron supplementation in patients with hemoglobin under 15 g per dL; and patients in Group 3 were in the control group that received no iron medication. A modest ABD program involving weekly phlebotomy and threshold hemoglobin values for donation of 11.5 g per dL in women and 12.0 g per dL in men was performed. RESULTS Ninety patients, 15 women and 15 men in each of the three groups, completed the study. The mean net red cell production during ABD was no higher (p>0.2) in the iron-treated groups (Group 1: 473 +/- 178 mL; Group 2: 436 +/- 170 mL; Group 3 (controls): 397 +/- 174 mL). The mean number of autologous units donated per patient did not differ (p>0.7) among the groups (Group 1: 3.1 +/- 0.6; Group 2: 2.9 +/- 0.7; Group 3: 3.0 +/- 0.7). The proportion of patients who needed allogeneic blood transfusion showed no significant (p>0.4) advantage for iron treatment, (Group 1: 7%; Group 2: 20%; Group 3: 10%). CONCLUSION In non-iron-deficient patients undergoing modest ABD without erythropoietin therapy, neither oral nor i.v. application of iron during the preoperative period enhances the success of preoperative ABD.
Collapse
|
69
|
Zimmermann R, Linhardt C, Weisbach V, Büscher M, Zingsem J, Eckstein R. An analysis of errors in blood component transfusion records with regard to quality improvement of data acquisition and to the performance of lookback and traceback procedures. Transfusion 1999; 39:351-6. [PMID: 10220259 DOI: 10.1046/j.1537-2995.1999.39499235665.x] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
BACKGROUND Quality assurance of blood transfusion covers institutions, personnel, and procedures involved in preparing, issuing, and using blood components. The accuracy of data related to blood component transfusions is a tool for quality control in the transfusion service. STUDY DESIGN AND METHODS A study of the accuracy of data records of the transfusion service at the University Hospital of Erlangen, Germany, between June 1994 and May 1996 was carried out. All returned blood component transfusion report forms were examined for discrepancies between primary data records and clinical transfusion reports. RESULTS Blood components (n = 49,224) from allogeneic and autologous donations, packed red cells, fresh-frozen plasma, and platelet components that had been issued for transfusion were included in this evaluation. For 27.3 percent of all components issued, no transfusion report was returned to the blood bank. For the remaining 35,786 units, errors were found in 3.8 percent of the records. For 1.24 percent of all components, discrepant information related to the recipient's identity or the component's status was found; this affected the feasibility of lookback or traceback searches. CONCLUSION A remarkably high frequency of discrepancies exists between computerized blood bank records and the information recorded on returned blood transfusion forms. The processes of data acquisition and entry must be included in quality assurance efforts in transfusion medicine.
Collapse
|
70
|
Weisbach V, Wanke C, Zingsem J, Zimmermann R, Eckstein R. Cytokine Generation in Whole Blood, Leukocyte-Depleted and Temporarily Warmed Red Blood Cell Concentrates. Vox Sang 1999. [DOI: 10.1046/j.1423-0410.1999.7620100.x] [Citation(s) in RCA: 43] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
71
|
Glaser A, Zimmermann R, Zingsem J, Weisbach V, Neidhardt B, Eckstein R. Veränderungen der Spenderausschlußrate bei der Gewinnung von Apheresespendern durch die Neufasssung der «Richtlinien zur Blutgruppenbestimmung und Bluttransfusion (Hämotherapie)». Transfus Med Hemother 1999. [DOI: 10.1159/000053508] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
|
72
|
Weisbach V, Wanke C, Zingsem J, Zimmermann R, Eckstein R. Cytokine generation in whole blood, leukocyte-depleted and temporarily warmed red blood cell concentrates. Vox Sang 1999; 76:100-106. [PMID: 10085526] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
BACKGROUND AND OBJECTIVES It has been suggested that inflammatory cytokines such as Interleukin (IL)-1beta, IL-6, tumor necrosis factor-alpha (TNF-alpha) and IL-8 might be responsible for a large number of non-antibody-mediated adverse reactions to the transfusion of blood components, especially of platelet concentrates (PCs). The aim of this study was to compare the levels of proinflammatory cytokines in different blood components containing red cells such as buffy-coat-free packed red cells (RBCs), filtered RBCs and whole blood (WB) during storage under several conditions. MATERIALS AND METHODS WB (CPD-A1, n = 16) was stored for 35 days at 2-6 degrees C; samples were taken on days 0, 21 and 35. Buffy-coat-poor RBCs in additive solution PAGGS-M (n = 16) were divided into halves, one half was leukocyte (WBC)-depleted by filtration on day 0, both halves were stored for 49 days at 2-6 degrees C (samples: days 0, 21, 49). Furthermore, buffy-coat-poor, unfiltered SAG-M RBCs (n = 16) were halved immediately after production and stored at 2-6 degrees C until day 42 (samples: days 0, 21, 42). One half remained at room temperature for 24 h on day 3. Cytokine levels were determined with commercial enzyme-linked immunosorbent assays. RESULTS Levels of IL-1beta and TNF-alpha rose during storage of WB and RBCs. IL-6 could be detected markedly above the detection threshold in WB only. At the end of storage, we detected IL-8 in 1 of 16 units of WB tested, in 10 of 16 standard PAGGS-M RBCs and in 15 of 16 temporarily warmed SAG-M RBCs. Prestorage filtration of RBCs prevented the accumulation of IL-1beta and TNF-alpha. Temporarily warming of RBCs for 24 h did not cause any substantial increase in cytokine levels other than IL-8. RBCs stored in different additive solutions (PAGGS-M versus SAG-M) showed similar cytokine concentrations during storage. The cytokine content of WB was very similar to that of buffy-coat-poor RBCs. CONCLUSION Cytokine levels measured in WB and buffy-coat-poor RBCs result in levels which are unlikely to cause febrile reactions even in the case of massive transfusion. We conclude that, according to present knowledge, there is no reason for prestorage filtration of buffy-coat-poor RBCs or WB to avoid febrile transfusion reactions due to cytokine accumulation during storage.
Collapse
|
73
|
Zimmermann R, Handtrack D, Zingsem J, Weisbach V, Neidhardt B, Glaser A, Eckstein R. A survey of blood utilization in children and adolescents in a German university hospital. Transfus Med 1998; 8:185-94. [PMID: 9800290 DOI: 10.1046/j.1365-3148.1998.00159.x] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
There are no detailed data on blood use with regard to diagnoses of recipients during infancy, childhood and adolescence. Available information on this issue is incomplete and no longer current. We conducted a survey of blood component use in children and adolescents in an acute-care university hospital in the greater area of Nuremberg between June 1994 and September 1996. Packed red blood cells (RBCs), fresh-frozen plasmas (FFPs) and platelet (PLT) components were evaluated for the recipients discharge diagnoses. Source study files were extracted from the hospital transfusion service and the medical records department. Transfused units were listed by broad diagnostic categories and leading diagnostic groups formed from principal diagnoses of the recipients according to the International Classification of Diseases, 9th edn (ICD-9). 34.3% of 2869 RBC cell units, 35.0% of 1095 FFP units and 5.0% of 1028 PLT components were used in patients with congenital diseases, mainly cardiac defects. The disease category neoplastic diseases was next most frequently associated with blood transfusion diagnosed in recipients of 23.9% of all RBCs, 15.6% of all FFP units and in 66.4% of all PLT units. Malignant diseases and benign haematological diseases (diagnostic categories II and IV) accounted for 68.9% of all costs of blood component transfusion. These findings demonstrate the increased importance of platelet transfusion for the organization of local and regional blood donation programmes and for cost analysis exercises. The study shows that detailed information on local blood use may be obtained quickly using available data collections of transfusion services and medical record departments.
Collapse
|
74
|
Zingsem J, Weisbach V, Zeiler T, Zimmermann R, Wittmann G, Eckstein R. [MLC reactivity demonstrates transfusion-induced immunosuppression]. BEITRAGE ZUR INFUSIONSTHERAPIE UND TRANSFUSIONSMEDIZIN = CONTRIBUTIONS TO INFUSION THERAPY AND TRANSFUSION MEDICINE 1998; 32:293-6. [PMID: 9480111] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
The improved graft survival in preoperatively transfused renal transplant recipients led to the hypothesis that blood transfusions have an immunosuppressive effect. We examined 12 patients undergoing cardiac surgery, who received autologous red cells and one homologous HLA class-I-matched platelet concentrate. None of these patients produced red cell or lymphocytotoxic antibodies. Using the mixed lymphocyte culture (MLC) we observed a reduced lymphocyte responce to cells of the platelet donor during the first 4 days after transfusion. The MLC reactivity recovered on days 4-5 to the initial strength and reached over 200% of the initial strength from day 6 on. It must be assumed that these changes in MLC reactivity represent the early signs of the transfusion-induced immunosuppression. As intraoperative transfusions might correlate with cancer relapse, further studies must show whether this immunosuppressive effect can be avoided by the application of filtered leucocyte-depleted red cell transfusions.
Collapse
|
75
|
Wittmann G, Zingsem J, Zeiler T, Zimmermann R, Eckstein R. [Effect of various rabbit complement batches of HLA class I antigen determination in lymphocytotoxicity testing]. BEITRAGE ZUR INFUSIONSTHERAPIE UND TRANSFUSIONSMEDIZIN = CONTRIBUTIONS TO INFUSION THERAPY AND TRANSFUSION MEDICINE 1998; 32:300-2. [PMID: 9480113] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
HLA class I lymphocytotoxicity testing is strongly complement-dependent. We tested 13 commercially available rabbit complement batches (7 distributors) using a panel of 14 donors with decisive patterns of HLA antigens. We defined a scoring system that weights the different possible faulty reactions. The rating score ranged from 12.45 to 46.55 (median 16.09). Comparing the reactions in batches with low and high rating scores gave statistically significant differences (chi 2 test, p < 0.05). Our complement reaction score may be helpful to find the optimal complement batch for HLA class I lymphocytotoxicity testing.
Collapse
|