51
|
Berg R, Andersson-Engels S, Jarlman O, Svanberg S. Time-gated viewing studies on tissuelike phantoms. APPLIED OPTICS 1996; 35:3432-3440. [PMID: 21102732 DOI: 10.1364/ao.35.003432] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
A time-gated technique to enhance viewing through highly scattering media such as tissue is discussed. Experiments have been performed on tissuelike plastic phantoms to determine the possibilities and limitations of the technique. The effects of the time-gate width and the localization, size, and optical properties of hidden objects have been studied. A computer model to simulate light propagation in tissue is also presented. The predictions of the model are compared with experimental results.
Collapse
|
52
|
Jarlman O, Berg R, Andersson-Engels S, Svanberg S, Pettersson H. Laser transillumination of breast tissue phantoms using time-resolved techniques. Eur Radiol 1996; 6:387-92. [PMID: 8798011 DOI: 10.1007/bf00180619] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
The objective of this study was to evaluate a pulsed laser transillumination technique based on time-resolved detection on breast-tissue-like phantoms. Experiments have been performed on tissue-like plastic phantoms with different scattering characteristics. The effects of time-gate width, size, localisation and refractive index of hidden objects have been scrutinised. Our study showed that the shorter the time-gate the higher the contrast. The contrast is very dependent on the size of the hole, whereas the full width half maximum is not. Furthermore, the investigation showed that the changes of early detected light in an experimental setting is due to scattering, and not to a higher speed of the transmitted light.
Collapse
|
53
|
Caiyan L, Kröll S, Sturesson L, Svanberg S. Observation of strongly subhomogeneous linewidths using high-contrast transmission spectroscopy: Experiment and theory. PHYSICAL REVIEW. A, ATOMIC, MOLECULAR, AND OPTICAL PHYSICS 1996; 53:1668-1677. [PMID: 9913059 DOI: 10.1103/physreva.53.1668] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
|
54
|
Caiyan L, Berzinsh U, Zerne R, Svanberg S. Determination of radiative lifetimes of neutral bismuth by time-resolved uv-vuv laser spectroscopy. PHYSICAL REVIEW. A, ATOMIC, MOLECULAR, AND OPTICAL PHYSICS 1995; 52:1936-1941. [PMID: 9912450 DOI: 10.1103/physreva.52.1936] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
|
55
|
Fill E, Borgström S, Larsson J, Starczewski T, Wahlström C, Svanberg S. xuv spectra of optical-field-ionized plasmas. PHYSICAL REVIEW. E, STATISTICAL PHYSICS, PLASMAS, FLUIDS, AND RELATED INTERDISCIPLINARY TOPICS 1995; 51:6016-6027. [PMID: 9963341 DOI: 10.1103/physreve.51.6016] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
|
56
|
Andersson-Engels S, Johansson J, Svanberg S. Medical diagnostic system based on simultaneous multispectral fluorescence imaging. APPLIED OPTICS 1994; 33:8022-9. [PMID: 20963019 DOI: 10.1364/ao.33.008022] [Citation(s) in RCA: 27] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
A multicolor fluorescence imaging system applied to medical diagnostics is described. The system presented simultaneously records four fluorescence images in different wavelength bands, permitting low-resolution spectroscopy imaging. An arithmetic function image of the four spectral images is constructed by a pixel-to-pixel calculation and is presented on a monitor in false-color coding. A sensitive detector is required for minimizing the excitation energy necessary to obtain an image and thus avoid side effects on the investigated tissue. Characteristics of the system of importance for the detector sensitivity as well as image quality are discussed. A high degree of suppression of ambient background light is reached with this system by the use of a pulsed laser as an excitation source together with gated detection. Examples of fluorescence images from tumors on the hind legs and in the brain of rats injected with Photofrin are given.
Collapse
|
57
|
Alian W, Andersson-Engels S, Svanberg K, Svanberg S. Laser-induced fluorescence studies of meso-tetra(hydroxyphenyl)chlorin in malignant and normal tissues in rats. Br J Cancer 1994; 70:880-5. [PMID: 7947093 PMCID: PMC2033525 DOI: 10.1038/bjc.1994.414] [Citation(s) in RCA: 47] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023] Open
Abstract
meso-Tetra(hydroxyphenyl)chlorin (mTHPC) is an attractive second-generation dihydroporphyrin photosensitiser for use in photodynamic therapy. In this study, 1.3 mg kg-1 body weight mTHPC was administered intravenously, and laser-induced fluorescence was used to characterise and compare its localisation and retention in different rat tissues, including an induced experimental adenocarcinoma, 24 h and 48 h post injection. These studies were performed in an attempt to predict the anatomical locations where mTHPC PDT might be most effective and suggest suitable injection--irradiation intervals in each case. Of particular interest were the intra-abdominal and intrathoracic tissues. The fluorescence was induced at 405 nm and the fluorescence spectrum in the region 450-750 nm was analysed. All collected spectra were dominated by the fluorescence signature of mTHPC with its peak at 652 nm, and all values in this study are in terms of background-free drug-specific fluorescence intensity at that wavelength. The photosensitiser accumulated in high concentrations in the tumour and the reticuloendothelial system. Muscular organs, such as the heart and the abdominal wall, were characterised by a low drug fluorescence signature.
Collapse
|
58
|
Nilsson H, Johansson J, Svanberg K, Svanberg S, Jori G, Reddi E, Segalla A, Gust D, Moore AL, Moore TA. Laser-induced fluorescence in malignant and normal tissue in mice injected with two different carotenoporphyrins. Br J Cancer 1994; 70:873-9. [PMID: 7947092 PMCID: PMC2033524 DOI: 10.1038/bjc.1994.413] [Citation(s) in RCA: 21] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023] Open
Abstract
Laser-induced fluorescence (LIF) was used to characterise the localisation of an intravenously administered trimethylated carotenoporphyrin [CP(Me)3] and a trimethoxylated carotenoporphyrin [CP(OMe)3] in an intramuscularly transplanted malignant tumour (MS-2 fibrosarcoma) and healthy muscle in female Balb/c mice, 3, 24, 48 and 96 h post injection. The fluorescence was induced with a dye laser pumped by a nitrogen laser, emitting light at 425 nm. The fluorescence spectra were recorded in the region 455-760 nm using a polychromator equipped with an image-intensified CCD camera. The tumour/peritumoral muscle ratio was about 5:1 for CP(Me)3 and about 6:1 for CP(OMe)3 in terms of the background-free fluorescence intensity, which peaked at about 655 nm. By including the endogenous tissue fluorescence, the contrast was further enhanced by a factor of approximately 2.
Collapse
|
59
|
Klavins J, Jansons M, Ekers A, Caiyan L, Svanberg S. Ionization in collisions between excited sodium dimers and atoms. Chem Phys Lett 1994. [DOI: 10.1016/0009-2614(94)00946-5] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
60
|
Kauranen P, Hertz HM, Svanberg S. Tomographic imaging of fluid flows by the use of two-tone frequency-modulation spectroscopy. OPTICS LETTERS 1994; 19:1489-1491. [PMID: 19855562 DOI: 10.1364/ol.19.001489] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
Diode laser absorption measurements obtained with two-tone frequency-modulation spectroscopy (TTFMS) are combined with tomography to produce spatially resolved quantitative images of fluid flows. The high sensitivity, good accuracy, and high stability of TTFMS absorption measurements permit optical-absorption tomography to be performed with low noise on extremely weakly absorbing objects. The method is demonstrated on a small oxygen flow with a GaAlAs diode laser operating near 760 nm and with an absorption sensitivity of 1:10(6).
Collapse
|
61
|
Gaarde MB, Zerne R, Caiyan L, Zhankui J, Larsson J, Svanberg S. Determination of radiative lifetimes of excited states in neutral gold using time-resolved vacuum-ultraviolet laser spectroscopy. PHYSICAL REVIEW. A, ATOMIC, MOLECULAR, AND OPTICAL PHYSICS 1994; 50:209-213. [PMID: 9910884 DOI: 10.1103/physreva.50.209] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
|
62
|
Svanberg K, Andersson T, Killander D, Wang I, Stenram U, Andersson-Engels S, Berg R, Johansson J, Svanberg S. Photodynamic therapy of non-melanoma malignant tumours of the skin using topical delta-amino levulinic acid sensitization and laser irradiation. Br J Dermatol 1994; 130:743-51. [PMID: 8011500 DOI: 10.1111/j.1365-2133.1994.tb03412.x] [Citation(s) in RCA: 329] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
Eighty basal cell carcinomas (BCCs) in 21 patients, 10 lesions of Bowen's disease in three patients, and four lesions of cutaneous T-cell lymphoma in two patients, were treated with photodynamic laser therapy (PDT), using topical application of the haem precursor delta-amino levulinic acid (ALA). The diagnoses were confirmed histologically prior to treatment. Fifty-five of the BCCs were superficial lesions, and 25 were nodular. Of the 80 BCCs, 39 (49%) were located on the trunk, 36 (45%) on the head and neck region, four (15%) on the leg and one on the arm. The two principal locations of the 10 Bowen's disease lesions were the leg (50%) and the trunk (40%). The T-cell lymphoma lesions were located on the shoulder and on the arm. A water-in-oil based cream containing 20% ALA was applied to the lesions, with a margin of about 10-20 mm beyond the visible tumour border, 4-6 h before the laser procedure. During this period of time the highly fluorescent and photodynamically active substance protoporphyrin IX (Pp IX) is synthesized via the haem cycle. Laser-induced fluorescence (LIF) was used for real-time monitoring of the Pp IX distribution in the tumour and in the normal surrounding skin, before and after treatment in all patients. Before laser treatment the Pp IX distribution demonstrated by LIF showed a demarcation between tumour and normal skin of about 15:1 for BCC and Bowen's disease, and 5:1 for T-cell lymphomas.(ABSTRACT TRUNCATED AT 250 WORDS)
Collapse
|
63
|
Edner H, Johansson J, Svanberg S, Wallinder E. Fluorescence lidar multicolor imaging of vegetation. APPLIED OPTICS 1994; 33:2471-2479. [PMID: 20885598 DOI: 10.1364/ao.33.002471] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
Multicolor imaging of vegetation fluorescence following laser excitation is reported for distances of 50 m. A mobile laser-radar system equipped with a Nd:YAG laser transmitter and a 40-cm-diameter telescope was utilized. The laser light was Raman shifted to 397 nm with pulse energies of ˜ 30 mJ. An image-intensified CCD camera with a specially designed split-mirror Cassegrainian telescope was utilized for the simultaneous recording of fluorescence images of leaves and branches in four different spectral bands. Additionally, fluorescence spectra at selected points within the detection area were measured with an image-intensified diode array system. Image processing permits extraction of information related to the physiological status of the vegetation and might prove useful in forest decline research.
Collapse
|
64
|
Zerne R, Larsson J, Svanberg S. Determination of radiative lifetimes in the 3d10np 2P sequence of neutral copper by time-resolved vuv laser spectroscopy. PHYSICAL REVIEW. A, ATOMIC, MOLECULAR, AND OPTICAL PHYSICS 1994; 49:128-131. [PMID: 9910213 DOI: 10.1103/physreva.49.128] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
|
65
|
Edner H, Ragnarson P, Svanberg S, Wallinder E, Ferrara R, Cioni R, Raco B, Taddeucci G. Total fluxes of sulfur dioxide from the Italian volcanoes Etna, Stromboli, and Vulcano measured by differential absorption lidar and passive differential optical absorption spectroscopy. ACTA ACUST UNITED AC 1994. [DOI: 10.1029/94jd01515] [Citation(s) in RCA: 69] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
66
|
Larsson J, Zerne R, Persson A, Wahlstr�m CG, Svanberg S. Determination of radiative lifetimes in the 3snp 1 P 1 sequence of Mg I using time-resolved VUV laser spectroscopy. ACTA ACUST UNITED AC 1993. [DOI: 10.1007/bf01437465] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
67
|
Wahlström C, Larsson J, Persson A, Starczewski T, Svanberg S, Salières P, Balcou P, L'Huillier A. High-order harmonic generation in rare gases with an intense short-pulse laser. PHYSICAL REVIEW. A, ATOMIC, MOLECULAR, AND OPTICAL PHYSICS 1993; 48:4709-4720. [PMID: 9910180 DOI: 10.1103/physreva.48.4709] [Citation(s) in RCA: 34] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/28/2023]
|
68
|
Andersson-Engels S, Berg R, Persson A, Svanberg S. Multispectral tissue characterization with time-resolved detection of diffusely scattered white light. OPTICS LETTERS 1993; 18:1697-1699. [PMID: 19823488 DOI: 10.1364/ol.18.001697] [Citation(s) in RCA: 27] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
A novel technique for the noninvasive measurement of tissue optical properties simultaneously at all visible and near-infrared wavelengths is presented. The technique is based on the time-resolved detection of multicolor diffusely scattered light. Short pulses of white light are produced by using self-phase modulation by focusing the light from a short-pulsed high-power laser into a cuvette filled with water. After spectral dispersion in a polychromator and temporal dispersion in a streak tube, a two-dimensional CCD camera was used as a detector, with one dimension used for time resolution and the other one for wavelength separation.
Collapse
|
69
|
Herrlin K, Svahn G, Olsson C, Pettersson H, Tillman C, Persson A, Wahlström CG, Svanberg S. Generation of x rays for medical imaging by high-power lasers: preliminary results. Radiology 1993; 189:65-8. [PMID: 8372221 DOI: 10.1148/radiology.189.1.8372221] [Citation(s) in RCA: 50] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
PURPOSE To evaluate the use of x-ray imaging performed with a high-power laser system in biologic and medical studies. MATERIALS AND METHODS A compact terawatt laser system based on chirped pulse amplification in titanium-doped sapphire was used. X rays were generated by irradiating a high-atomic-number target (tantalum). RESULTS When photons with an energy below 10 keV were removed with use of 3 mm of aluminum, the half-value layer in aluminum for the remaining x rays was approximately 10 mm. The x-ray source allowed performance of biologic magnification radiography. Star-pattern tests indicated an equivalent focal spot size of less than 60 microns. Exposures of a single pulse could be obtained. The duration of a single x-ray pulse was estimated to be of the order of picoseconds. CONCLUSION With use of subpicosecond laser pulses, x-ray generation can occur with a smaller equivalent focal spot size than with conventional x-ray sources.
Collapse
|
70
|
Andersson-Engels S, Ankerst J, Johansson J, Svanberg K, Svanberg S. Laser-induced fluorescence in malignant and normal tissue of rats injected with benzoporphyrin derivative. Photochem Photobiol 1993; 57:978-83. [PMID: 8367537 DOI: 10.1111/j.1751-1097.1993.tb02958.x] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
Laser-induced fluorescence was used to characterize the localization of intravenously administered benzoporphyrin derivative-monoacid (BPD-MA) 3 h postinjection in different rat tissue types, including an induced experimental malignant tumor. A comparison of the fluorescence properties and demarcation potential between the newer sensitizer BPD-MA and four other substances, hematoporphyrin (HP), polyhematoporphyrin ester (PHE), tetrasulfonated phthalocyanine (TSPc) and the commercially available Photofrin earlier investigated, is included. The fluorescence light was induced with a nitrogen laser, emitting at 337 nm. The fluorescence spectrum in the region 380-750 nm was analyzed by a polychromator equipped with a diode array detector. The demarcation potential between tumor and surrounding tissue in terms of fluorescence signal for the tumor model used was 2:1 for BPD-MA. In comparison with the other drugs, HP shows about the same demarcation potential, whereas Photofrin and PHE exhibit about 3 times better and TSPc about 1.5 times better demarcation. By also employing the endogenous tissue fluorescence signature the contrast was enhanced by a factor of about 2 for each of the five drugs.
Collapse
|
71
|
Baert L, Berg R, Van Damme B, D'Hallewin MA, Johansson J, Svanberg K, Svanberg S. Clinical fluorescence diagnosis of human bladder carcinoma following low-dose Photofrin injection. Urology 1993; 41:322-30. [PMID: 8470316 DOI: 10.1016/0090-4295(93)90588-2] [Citation(s) in RCA: 52] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
A point-monitoring fluorescence diagnostic system based on a low-energy pulsed laser, fiber transmission optics, and an optical multichannel analyzer was used for diagnosis of patients with bladder malignancies. Twenty-four patients with bladder carcinoma, carcinoma in situ, and/or dysplasia were injected with hematoporphyrin derivative, Photofrin, 0.35 or 0.5 mg/kg body weight, forty-eight hours prior to the investigation. The ratio between the red sensitizer emission and the bluish tissue autofluorescence provided excellent demarcation between papillary tumors and normal bladder wall. Certain cases of dysplasia also could be differentiated from normal mucosa. Benign exophytic lesions such as malakoplakia appeared different from malignant tumors in fluorescence. Flat suspicious bladder mucosa such as seen in infectious diseases or after radiation therapy appeared normal on fluorescence.
Collapse
|
72
|
Berg R, Jarlman O, Svanberg S. Medical transillumination imaging using short-pulse diode lasers. APPLIED OPTICS 1993; 32:574-579. [PMID: 20802727 DOI: 10.1364/ao.32.000574] [Citation(s) in RCA: 27] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
The recently introduced time-resolved technique for enhanced medical transillumination imaging has been demonstrated for the important case of a diode laser transmitter. This type of gated-viewing technique utilizes early received light only to reject multiply scattered, delayed light, normally blurring the image. Human breast-cancer detection is demonstrated in vitro, and the observations are explained by using theoretical modeling and tissue phantom experiments.
Collapse
|
73
|
Edner H, Ragnarson P, Spännare S, Svanberg S. Differential optical absorption spectroscopy (DOAS) system for urban atmospheric pollution monitoring. APPLIED OPTICS 1993; 32:327-333. [PMID: 20802694 DOI: 10.1364/ao.32.000327] [Citation(s) in RCA: 26] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
We describe a fully computer-controlled differential optical absorption spectroscopy system for atmospheric air pollution monitoring. A receiving optical telescope can sequentially tune in to light beams from a number of distant high-pressure Xe lamp light sources to cover the area of a medium-sized city. A beam-finding servosystem and automatic gain control permit unattended long-time monitoring. Using an astronomical code, we can also search and track celestial sources. Selected wavelength regions are rapidly and repetitively swept by a monochromator to sensitively record the atmospheric absorption spectrum while avoiding the detrimental effects of atmospheric turbulence. By computer fitting to stored laboratory spectra, we can evaluate the path-averaged concentration of a number of important pollutants such as NO(2), SO(2), and O(3). A measurement of NH(3) and NO close to the UV limit is also demonstrated.
Collapse
|
74
|
Andersson-Engels S, Berg R, Svanberg S. Effects of optical constants on time-gated transillumination of tissue and tissue-like media. JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY. B, BIOLOGY 1992; 16:155-67. [PMID: 1474424 DOI: 10.1016/1011-1344(92)80006-h] [Citation(s) in RCA: 28] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
Light transillumination was used to study structures inside turbid media. Time-gated viewing was performed to suppress multiply-scattered light and thus improve spatial resolution. We demonstrate that, for the case of scattering-dominated attenuation (scattering coefficient much greater than the absorption coefficient), the detection of early transmitted light will be practically insensitive to variations in the absorption coefficient. This is an important observation for the development of time-gated optical mammography, since optical mammography using continuous-wave light is based on increased light absorption in the tumour region caused by the neovascularization surrounding a tumour. In order to detect tumours in time-gated viewing it is the scattering coefficient of the tumour that must be characteristic. The scattering coefficient is measured to be lower in the tumour region than in the surrounding breast tissue for one resected breast specimen.
Collapse
|
75
|
Jarlman O, Berg R, Svanberg S. Time-resolved transillumination of the breast. Acta Radiol 1992; 33:277-9. [PMID: 1591135] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
|