101
|
Belfort MA, Dildy GA, Saade GR, Suarez V, Clark SL. Prediction of shoulder dystocia using multivariate analysis. Am J Perinatol 2007; 24:5-10. [PMID: 17195152 DOI: 10.1055/s-2006-954956] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
We evaluated the use of multivariate analysis in the prediction of shoulder dystocia (SD). One hundred consecutive cases with SD were matched with 100 controls without dystocia. All patients had term, vaginal delivery. Multivariate analysis was used to identify independent variables significantly related to shoulder dystocia. The regression coefficients for the identified factors were used to calculate a composite score from which receiver operating characteristics (ROC) curves were derived. Birthweight (BW), 1-hour Glucola (GLU), operative vaginal delivery (OVD), and height of fundus (HOF) were related independently to SD. The sensitivity and specificity reached 84 and 80%, respectively, with BW + GLU + OVD. Significant associations persisted when HOF and carbohydrate intolerance were substituted for BW and GLU, respectively. SD is independently associated with BW, GLU, and OVD, and may be predicted with clinically acceptable accuracy using multiple variables. This model may be useful in the design of prospective studies for managing suspected macrosomia.
Collapse
|
102
|
Belfort MA, Clark SL, Sibai B. Cerebral Hemodynamics in Preeclampsia: Cerebral Perfusion and the Rationale for an Alternative to Magnesium Sulfate. Obstet Gynecol Surv 2006; 61:655-65. [PMID: 16978425 DOI: 10.1097/01.ogx.0000238670.29492.84] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
UNLABELLED Preeclampsia and eclampsia continue to be major causes of maternal death. Currently, approximately 18% of U.S. maternal deaths are attributed to hypertensive disorders and eclampsia, and several hundred women die from eclampsia and its complications every year. In the United States, preeclamptic women have received magnesium sulfate as a seizure prophylaxis agent for 3 decades, and this practice is becoming more widely accepted internationally. In addition to a recognized failure rate, there are financial, logistic, and safety concerns associated with the universal administration of magnesium sulfate. Many institutions in the developing world lack the necessary equipment and expertise to administer the medication, and many preeclamptic patients thus do not receive magnesium sulfate before their first seizure. As effective as it has been in reducing mortality from eclampsia, magnesium sulfate is also associated with appreciable morbidity and mortality from administration errors and magnesium toxicity. The availability of an easily administered, cheap, safe, and orally administered alternative to magnesium sulfate would be welcomed in the developing world and would provide an extremely useful alternative therapy to the current standard of care. Recent advances in the understanding of the pathophysiology of preeclampsia and eclampsia, primarily related to cerebral perfusion and blood flow, could allow us to reduce the seizure rate in treated preeclamptic women even further than what is currently reported. This article deals with the rationale behind the use of labetalol as an alternative to magnesium sulfate for the prevention of eclampsia. TARGET AUDIENCE Obstetricians & Gynecologists, Family Physicians. LEARNING OBJECTIVES After completion of this article, the reader should be able to recall that hypertensive diseases of pregnancy contribute a significant portion of today's maternal mortality, explain that methods of preventing eclampsia are not applicable worldwide, and state that understanding of the pathophysiology of preeclampsia/eclampsia may assist in developing safe and effective medications that can be used universally.
Collapse
|
103
|
Clark SL, Blatter DD, Jackson GM. Placement of a temporary vena cava filter during labor. Am J Obstet Gynecol 2005; 193:1746-7. [PMID: 16260221 DOI: 10.1016/j.ajog.2005.05.014] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2005] [Revised: 04/06/2005] [Accepted: 04/16/2005] [Indexed: 10/25/2022]
Abstract
Placement of a vena cava filter for the prevention of pulmonary thromboembolism in select patients is a well established procedure in critical care medicine. We describe a case of placement and removal of a new removable vena cava filter in a pregnant patient, in this case during early labor. Vaginal delivery was accomplished without incident.
Collapse
|
104
|
Clark SL, Crowley AJ, Schmidt PG, Donoghue AR, Piché CA. Long-term delivery of ivermectin by use of poly(D,L-lactic-co-glycolic)acid microparticles in dogs. Am J Vet Res 2004; 65:752-7. [PMID: 15198214 DOI: 10.2460/ajvr.2004.65.752] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
OBJECTIVE To evaluate the potential utility of poly(D,L-lactic-co-glycolic)acid (PLGA) as a long-acting biodegradable drug delivery matrix for ivermectin used in the prevention of heartworm disease in dogs. ANIMALS 30 adult female dogs. PROCEDURE Microparticle formulations containing 25 weight percent (wt%), 35 wt%, and 50 wt% ivermectin were prepared by an oil-in-water emulsion technique with solvent extraction into excess water. A fourth formulation, consisting of a mixture of 15 wt% and 50 wt% ivermectin microparticles, was blended in a 1:1 ratio to result in a 32.5 wt% ivermectin formulation. Formulations were administered once on Day 0 to groups of 6 dogs at a dose of 0.5 mg of ivermectin/kg, s.c. Half of the dogs in each treatment group and 3 untreated control dogs were infected with Dirofilaria immitis larvae 121 and 170 days after treatment. Six months after infection, dogs were euthanatized and necropsies were performed. Pharmacokinetics and efficacy were investigated. RESULTS Analysis of pharmacokinetic data revealed sustained release of ivermectin during at least 287 days in 3 distinct phases: a small initial peak, followed by release of drug through diffusion, and polymer degradation. Untreated control dogs were all infected with heartworms. Heartworms were not found in any of the dogs in the ivermectin-PLGA treated groups. Adverse clinical signs were not observed. CONCLUSIONS AND CLINICAL RELEVANCE All formulations were 100% effective in preventing development of adult heartworms. Results indicate that PLGA microparticles are a promising drug delivery matrix for use with ivermectin for the prevention of heartworm disease for at least 6 months after treatment.
Collapse
|
105
|
Phelan JP, Clark SL, Diaz F, Paul RH. Vaginal birth after cesarean. Int J Gynaecol Obstet 2004. [DOI: 10.1016/0020-7292(88)90170-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
106
|
Clark SL, Sabey P, Jolley K. Nonstress testing with acoustic stimulation and amniotic fluid volume assessment: 5973 tests without unexpected fetal death. Int J Gynaecol Obstet 2004. [DOI: 10.1016/0020-7292(89)90439-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
107
|
Clark SL. Elective induction: an analysis of economic and health consequences. Am J Obstet Gynecol 2003; 188:1664-5; author reply 1665. [PMID: 12825016 DOI: 10.1067/mob.2003.430] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
108
|
Clark SL, Hankins GDV. Temporal and demographic trends in cerebral palsy--fact and fiction. Am J Obstet Gynecol 2003; 188:628-33. [PMID: 12634632 DOI: 10.1067/mob.2003.204] [Citation(s) in RCA: 192] [Impact Index Per Article: 9.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
The rate of cerebral palsy has not decreased in developed countries over the past 30 years, despite the widespread use of electronic fetal heart rate monitoring and a 5-fold increase in the cesarean delivery rate over the same period of time. However, neonatal survival has improved during these decades. These observations have lead to the hypothesis that increased survival of premature, neurologically impaired infants may have masked an actual reduction in cerebral palsy among term infants as a result of the use of electronic monitoring and the avoidance of intrapartum asphyxia. A review of the medical literature, as well as a demographic analysis of term and preterm birth rates in the United States, refutes this hypothesis on four grounds. First, cerebral palsy prevalence has been separately analyzed in term infants and shows no change over 30 years. Second, the prevalence of cerebral palsy is the same or lower in underdeveloped countries than in developed nations; in the former, the availability of emergency cesarean delivery based on electronic monitor data is limited or absent. Third, the increase in prevalence of cerebral palsy among low-birth-weight infants and the increase in cesarean sections based on presumed fetal distress were not simultaneous events-the former preceded the latter by a decade. Improved neonatal survival since the 1980s has been associated with a stable or decreasing rate of neurologic impairment and thus could not have obscured improvement from reduced term asphyxia. Finally, compared with the number of infants born by cesarean section for fetal distress, there are simply not enough infants born in the most vulnerable weight groups to make any impact on even a minimal improvement of outcome in the group delivered by cesarean section for presumed fetal distress. Except in rare instances, cerebral palsy is a developmental event that is unpreventable given our current state of technology.
Collapse
|
109
|
Hansen SL, Clark SL, Foster JC. Active pushing versus passive fetal descent in the second stage of labor: a randomized controlled trial. Obstet Gynecol 2002; 99:29-34. [PMID: 11777506 DOI: 10.1016/s0029-7844(01)01642-8] [Citation(s) in RCA: 65] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
OBJECTIVE To compare perinatal outcomes among women with epidural anesthesia who were encouraged to push at complete dilatation with those who had a period of rest before pushing began. METHODS After a power analysis to determine appropriate sample size (based upon an alpha error rate of.05% and 80% power), a prospective randomized trial of 252 women with epidural anesthesia was conducted. Patients were randomized to a rest period or immediate pushing at complete dilatation. Variables measured included rate of fetal descent, length of time of pushing, the number and type of fetal heart rate decelerations, Apgar scores, arterial cord pH values, perineal injuries, type of delivery, length of second stage, maternal fatigue, and endometritis. RESULTS When a period of rest was used before pushing, we found a longer second stage, decreased pushing time, fewer decelerations, and, in primiparous women, less fatigue compared with control patients. Apgar scores, arterial cord pH values, rates of perineal injury, instrument delivery, and endometritis were similar in both groups. CONCLUSION Delayed pushing was not associated with demonstrable adverse outcome, despite second-stage length of up to 4.9 hours. In select patients, such delay may be of benefit.
Collapse
|
110
|
Mosen DM, Clark SL, Mundorff MB, Tracy DM, McKnight EC, Zollo MB. The medical and economic impact of the Newborns' and Mothers' Health Protection Act. Obstet Gynecol 2002; 99:116-24. [PMID: 11777521 DOI: 10.1016/s0029-7844(01)01660-x] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Abstract
OBJECTIVE We evaluated the effect of the Newborns' and Mothers' Health Protection Act on clinical and cost outcomes. METHODS We conducted an observational study of 18,023 healthy, mother-infant dyads before (n = 8670) and after (n = 9353) implementation of the Newborns' and Mothers' Health Protection Act legislation. Logistic regression was used to calculate adjusted odds ratios (ORs) for the following outcome measures: length of stay at least 48 hours, satisfaction with maternal length of stay, 7- and 30-day hospital readmission utilization, and 7- and 30-day emergency room utilization. Analysis of covariance was used to evaluate adjusted mean hospitalization costs per delivery. RESULTS Mothers in the postlegislation period were more likely to have hospital stays at least 48 hours (OR 3.99; 95% confidence interval [CI] 3.57, 4.44) and rate their length of stay as "about right" (OR 5.54; 95% CI 4.76, 6.46) compared with mothers in the prelegislation period. Neonates in the postlegislation period were more likely to have hospital stays of at least 48 hours (OR 3.96; 95% CI 3.54, 4.43) and less likely to be rehospitalized within 7 days after hospitalization (OR 0.61; 95% CI 0.40, 0.95) compared with neonates in the prelegislation period. Adjusted mean hospitalization costs increased $116 per delivery in the postlegislation period. CONCLUSIONS After implementation of the Newborns' and Mothers' Health Protection Act legislation, maternal and newborn length of stay and maternal satisfaction with length of stay increased substantially, and hospitalization costs increased significantly. The strongest clinical benefit was observed among neonates who were at a lower risk for hospitalization within 1 week of discharge. With the exception of 30-day emergency room utilization, there was insufficient statistical power to test for differences among other maternal clinical outcomes.
Collapse
|
111
|
Coffin SE, Clark SL. Induction of intestinal rotavirus-specific antibodies in respiratory, but not gut, lymphoid tissues following mucosal immunization of mice with inactivated rotavirus. Virology 2001; 291:235-40. [PMID: 11878893 DOI: 10.1006/viro.2001.1180] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Intranasal (i.n.), but not oral, immunization of mice with inactivated rotavirus induces protection against challenge. To understand the mechanisms by which i.n. immunization with inactivated rotavirus evokes protective immunity, we examined the site of rotavirus-specific B cell activation and the origins of intestinal IgA-secreting B cells following i.n. inoculation of mice with inactivated rhesus rotavirus. We found that (1) i.n., but not oral, inoculation induced partial protection after challenge; (2) i.n., but not oral, inoculation induced production of rotavirus-specific IgM, IgA, and IgG by intestinal lymphoid tissues; and (3) after i.n. inoculation, nasal-associated lymphoid tissues (NALT) and bronchial lymph nodes (BLN) were the sites of initial production of rotavirus-specific antibodies. These studies indicate that after inoculation with inactivated rotavirus, virus-specific effector B cells may be more easily activated in respiratory, compared to intestinal, lymphoid tissues. Additional studies are needed to determine if these observations are due to fundamental differences in the microenvironment of NALT and BLN compared to Peyer's patches or are a function of the anatomic differences between the respiratory and the gastrointestinal tracts.
Collapse
|
112
|
Clark SL, Teh SJ, Hinton DE. Tissue and cellular alterations in Asian clam (Potamocorbula amurensis) from San Francisco Bay: toxicological indicators of exposure and effect? MARINE ENVIRONMENTAL RESEARCH 2000; 50:301-305. [PMID: 11460709 DOI: 10.1016/s0141-1136(00)00100-8] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
The US Geological Survey has reported the presence of a metal contamination gradient in clam tissues, decreased condition indices, and irregular reproductive patterns have been reported in the Asian clam, Potamocorbula amurensis, from San Francisco Bay. If metals are driving the observed patterns in the field, then biomarkers of exposure, and possibly deleterious effect, should show a corresponding gradient. In this study, biomarkers from sub-cellular to tissue levels of biological organization were assessed in P. amurensis collected from the Bay or exposed to cadmium in the laboratory. Cellular and tissue alterations were assessed using histopathology and enzyme histochemistry (EH). Alterations in the ovary, testis, kidney, and gill tissues were most common at the most contaminated station when data were averaged over a 12-month sampling period. EH analysis indicated decreased active transport, energy status, and glucose oxidation in kidney and digestive gland at the most contaminated site which may indicate a decreased potential for growth. Ovarian lesions observed in feral Asian clams were experimentally induced in healthy clams by cadmium exposure in laboratory exposures. Our results suggest a contaminant etiology for tissue alterations.
Collapse
|
113
|
Abstract
Coumarin derivatives are the anticoagulants most widely used in the United States. These agents are relatively contraindicated during pregnancy, and the use of these drugs in breast-feeding women remains controversial. Much of the confusion regarding the passage of these agents into breast milk might stem from the fact that different agents possess significantly different chemical properties. A review of the chemical structure of different coumarin derivatives, as well as available clinical evidence, suggests that warfarin sodium is not excreted into breast milk, and can be safely given to women requiring therapeutic anticoagulation postpartum. For the rare patient who cannot tolerate warfarin sodium, the use of dicumarol, rather than anisindione, is preferred.
Collapse
|
114
|
|
115
|
Clark SL, Scott JR, Porter TF, Schlappy DA, McClellan V, Burton DA. Is vaginal birth after cesarean less expensive than repeat cesarean delivery? Am J Obstet Gynecol 2000; 182:599-602. [PMID: 10739514 DOI: 10.1067/mob.2000.104200] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
OBJECTIVE This study was undertaken to compare total medical costs of trial of labor after cesarean with those of elective repeat cesarean without labor, with both short- and long-term neonatal costs associated with such procedures taken into account. STUDY DESIGN Costs associated with All Patient Refined diagnosis-related groups and Current Procedural Terminology for a large not-for-profit health care system were applied to an algorithm describing maternal and neonatal outcomes of trial of labor. Perinatal morbidity rates and cost estimates for long-term neurologic damage associated with uterine rupture were derived from published literature. RESULTS If a 70% vaginal birth rate for women undergoing a trial of labor and delivery in a tertiary center with a mean uterine rupture to delivery time of 13 minutes is assumed, the net cost differential ranged from a saving of $149 to a loss of $217, depending on morbidity assumptions. For vaginal birth after cesarean success rates <70%, trial of labor in the presence of two previous scars, and institutional factors increasing the perinatal morbidity rate by just 4% with respect to that seen in tertiary centers, trial of labor resulted in a net financial loss to the health care system regardless of all other assumptions made. CONCLUSIONS When costs as opposed to charges are considered and the cost of long-term care for neurologically injured infants is taken into account, trial of labor after previous cesarean is unlikely to be associated with a significant cost saving for the health care system. Recent government-mandated length-of-stay requirements are likely to make the economic benefit of vaginal birth after cesarean even less favorable. Factors other than cost must govern decisions regarding trial of labor or repeat cesarean.
Collapse
|
116
|
Abstract
Both VAS and scalp stimulation are useful in the evaluation of fetal compromise by decreasing the number of falsely abnormal FHR tests and limiting the number of unnecessary interventions, thus improving the efficiency of antepartum and intrapartum FHR monitoring. As is true for all types of fetal assessment using FHR monitoring, VAS and scalp stimulation have limitations, and a lack of response to these methodologies does not necessarily indicate fetal acidemia. When either VAS or scalp stimulation is employed, one must take into consideration their respective predictive values (see Table 1). Fetal VAS or scalp stimulation should be considered as one facet of comprehensive fetal evaluation. When these techniques are used in this manner, the clinician evaluating the fetus in the antepartum or intrapartum period may prevent unnecessary intervention and improve maternal and neonatal outcome.
Collapse
|
117
|
Coffin SE, Clark SL, Bos NA, Brubaker JO, Offit PA. Migration of antigen-presenting B cells from peripheral to mucosal lymphoid tissues may induce intestinal antigen-specific IgA following parenteral immunization. JOURNAL OF IMMUNOLOGY (BALTIMORE, MD. : 1950) 1999; 163:3064-70. [PMID: 10477570] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Subscribe] [Scholar Register] [Indexed: 02/13/2023]
Abstract
Parenterally administered immunizations have long been used to induce protection from mucosal pathogens such as Bordetella pertussis and influenza virus. We previously found that i.m. inoculation of mice with the intestinal pathogen, rotavirus, induced virus-specific Ab production by intestinal lymphocytes. We have now used adoptive transfer studies to identify the cell types responsible for the generation of virus-specific Ab production by gut-associated lymphoid tissue (GALT) after i.m. immunization. Three days after i.m. immunization with rotavirus, cells obtained from the draining peripheral lymph nodes of donor mice were transferred into naive recipient mice. We found that intestinal lymphocytes produced rotavirus-specific Igs (IgM, IgA, and IgG) 2 wk after transfer of either unfractionated cells, or unfractionated cells rendered incapable of cellular division by mitomycin C treatment. Additional studies demonstrated that rotavirus-specific IgA, but not IgG, was produced by intestinal lymphocytes after transfer of purified B cells. Ig allotype analysis revealed that rotavirus-specific IgA was produced by intestinal B cells of recipient origin, suggesting that migration of Ag-presenting B cells from peripheral lymphoid tissues to GALT may contribute to the generation of mucosal IgA responses after parenteral immunization. Strategies that promote Ag uptake and presentation by B cells may enhance mucosal IgA production following parenteral immunization.
Collapse
|
118
|
Hankins GD, Clark SL, Uckan E, Van Hook JW. Maternal oxygen transport variables during the third trimester of normal pregnancy. Am J Obstet Gynecol 1999; 180:406-9. [PMID: 9988810 DOI: 10.1016/s0002-9378(99)70223-1] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
OBJECTIVE The aim of this study was to measure and calculate oxygen transport variables in uncomplicated term pregnancies. STUDY DESIGN Ten normotensive primiparous women between 36 and 38 weeks' gestation underwent pulmonary and radial arterial catheterization as part of a larger study. Seven women had studies repeated at approximately 12 weeks post partum. Measurements were made with patients in the left lateral recumbent position after a 30-minute stabilization period. Cardiac output was measured with the thermodilution technique. Blood samples were obtained simultaneously from the pulmonary and radial arteries and analyzed in duplicate for oxygen content with a blood gas analyzer. RESULTS The oxygen contents of both arterial and mixed venous blood are significantly lower (P <.05) in the third trimester of pregnancy (15.96 and 11.97 mL/dL, respectively) than in the postpartum period (18.00 and 13.54 mL/dL). The fall in oxygen content during pregnancy prevents any significant increase in oxygen delivery in the third trimester (867. 59 mL/min) relative to the postpartum period (806.50 mL/min, P not significant). CONCLUSION This is the first report of directly measured oxygen transport variables in healthy pregnant women.
Collapse
|
119
|
Clark SL, Xu W, Porter TF, Love D. Institutional influences on the primary cesarean section rate in Utah, 1992 to 1995. Am J Obstet Gynecol 1998; 179:841-5. [PMID: 9790356 DOI: 10.1016/s0002-9378(98)70175-9] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
OBJECTIVES Our purpose was to evaluate institutional and organizational influences on cesarean section rates in Utah and to adjust such rates for differences in patient acuity. STUDY DESIGN Data on cesarean section rates were derived from the Utah Hospital Discharge Database and adjusted for patient acuity by correcting raw cesarean rates for those patients undergoing cesarean section meeting regional gestational age transport criteria. RESULTS When analyzed by means of 1-way analysis of variance, the following factors had a significant negative correlation (P < .05) with cesarean section rate: presence of a newborn intensive care unit and maternal-fetal medicine subspecialists, presence on the medical staff of obstetrician-gynecologist(s) as opposed to family physicians only, delivery volume >1500/y, urban location, and 24-hour in-house anesthesiology. When cesarean rates were corrected for acuity, facilities with maternal-fetal medicine specialists and a newborn intensive care unit had significantly lower rates (P < .001) and more uniform rates than otherwise similar institutions. CONCLUSIONS More medically sophisticated physicians and institutions have lower cesarean rates when patient acuity is taken into account.
Collapse
|
120
|
|
121
|
Sen Gupta TK, Wallace DA, Clark SL, Bannan G. Videoconferencing: practical advice on implementation. Aust J Rural Health 1998; 6:2-4. [PMID: 9611492 DOI: 10.1111/j.1440-1584.1998.tb00273.x] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022] Open
Abstract
Videoconferencing provides a useful tool for improving information flow, with clinical, educational and administrative uses being particularly relevant to rural and remote Australia. This paper describes the range of possible uses for computer-based videoconferencing and describes the authors' experience in delivering rural medical education in North Queensland via videoconference. Principles that ensure successful videoconferencing are outlined and are applicable to a variety of formats and uses. They include the need to keep it simple, the importance of thorough preparation, and ensuring that education drives technology, rather than the converse.
Collapse
|
122
|
Dizon-Townson DS, Dildy GA, Clark SL. A prospective evaluation of fetal pericardial fluid in 506 second-trimester low-risk pregnancies. Obstet Gynecol 1997; 90:958-61. [PMID: 9397111 DOI: 10.1016/s0029-7844(97)00474-2] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
OBJECTIVE To measure fetal pericardial fluid in low-risk second-trimester pregnancies and to evaluate outcome for those with measurements greater than 2 mm. METHODS Five hundred and six women were referred for sonography between 16 and 25 weeks' gestation for common obstetric indications (dating, fetal survey, and placental location) unrelated to an increased risk of anomalies. All cases were evaluated with two-dimensional and M-mode real-time ultrasonography with the use of a mechanical sector transducer. The maximum distance of the fetal hypoechoic cardiac rim was recorded. We reviewed maternal and infant charts for those with measurements greater than 2 mm. RESULTS Median (range) maternal age was 25 (15-42) years. Median gravidity and parity were two (1-14) and one (0-11), respectively. Median estimated gestational age was 20.4 (16.3-24.9) weeks. Fetal pericardial fluid was seen in 360 of 506 (71%) fetuses. Of these 360 fetuses, the mean distance (+/- 2 standard deviation) of the fetal hypoechoic cardiac rim was 1.20 mm +/- 0.91 mm (95% confidence interval 1.15, 1.25). Among the 506 cases, the maximum measurement was 3 mm. Ten of the 506 (2%) cases had measurements greater than 2 mm. None of these ten fetuses had a cardiac structural abnormality or arrhythmia, and perinatal outcome was unremarkable. CONCLUSION During second-trimester fetal ultrasonographic examination, visualization of pericardial fluid up to 2 mm in the fetus with current high-resolution technology is common and should not be regarded as pathologic.
Collapse
|
123
|
Greenwood JE, Crawley BA, Clark SL, Chadwick PR, Ellison DA, Oppenheim BA, McCollum CN. Monitoring wound healing by odour. J Wound Care 1997; 6:219-21. [PMID: 9256726 DOI: 10.12968/jowc.1997.6.5.219] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
A pilot study using electronic aroma detection was performed over a six-month period to assess the aroma of chronic non-healing venous leg ulcers and the effect of appropriate antibiotic therapy on modification of the aroma. Deep infection with pathogenic organisms was found on biopsy culture in 13 out of 15 patients. Odour analysis was performed at weekly intervals on the ulcer dressings using an AromaScan instrument. Data points on the aroma maps moved from their pre-treatment presentation. Alterations in aroma data correlated well with the progress of the ulcers. Aroma analysis is shown to be a potential tool in monitoring the progress towards healing of chronic venous ulcers.
Collapse
|
124
|
Dildy GA, Clark SL, Garite TJ, Porter TF, Swedlow DB, Varner MW. Current status of the multicenter randomized clinical trial on fetal oxygen saturation monitoring in the United States. Eur J Obstet Gynecol Reprod Biol 1997; 72 Suppl:S43-50. [PMID: 9134412 DOI: 10.1016/s0301-2115(97)02717-6] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
Current clinical methods of intrapartum fetal assessment are sensitive but poorly specific in detecting fetal compromise during labor. These limitations have substantially contributed to the escalating cesarean section rate which occurred in the US during the last several decades. Experimental and clinical research efforts directed towards application of the oxygen saturation monitor (pulse oximeter) to intrapartum fetal assessment have produced encouraging results. If this new method of fetal assessment is to enter the clinical arena, safety and efficacy issues must first be properly evaluated via randomized clinical trials. The purpose of this report is to describe the design of a multicenter randomized clinical trial of intrapartum fetal oxygen saturation monitoring recently begun in the US. Specific aspects of the trial, including purpose, study design, sample size estimates, control and test groups, inclusion and exclusion criteria, fetal heart rate classification, definition of normal fetal arterial oxygen saturation (SpO2), clinical management protocol, and assessment of maternal-fetal outcomes will be addressed.
Collapse
|
125
|
Porter TF, Clark SL, Oshiro BT, Dildy GA, Varner MW, Branch DW, Tooke-Miller C. Survival and neurologic outcome of apparently stillborn infants. Am J Obstet Gynecol 1997. [DOI: 10.1016/s0002-9378(97)80106-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
126
|
Dildy GA, Judd VE, Clark SL. Prospective evaluation of the antenatal incidence and postnatal significance of the fetal echogenic cardiac focus: a case-control study. Am J Obstet Gynecol 1996; 175:1008-12. [PMID: 8885766 DOI: 10.1016/s0002-9378(96)80043-3] [Citation(s) in RCA: 44] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
OBJECTIVE We evaluated the antenatal incidence and postnatal significance of echogenic cardiac foci observed during antenatal ultrasonography. STUDY DESIGN During a 4-month period, all women undergoing dating ultrasonography between 16.0 and 24.9 weeks' gestation at one referral center were prospectively evaluated for an echogenic cardiac focus during an apical four-chamber view of the heart. Referrals for maternal or fetal complications were excluded. Postnatal echocardiography was performed for those identified with positive findings. Controls were selected from among normal subjects in the general group for comparison with the study group. RESULTS Five hundred six consecutive fetuses were evaluated at a mean +/- SD gestational age of 20.6 +/- 1.6 weeks. There were 25 (4.9%) fetuses found to have echogenic cardiac focus (left ventricle = 19, right ventricle = 6). Echocardiography was performed between 0.3 and 20.1 weeks postdelivery. After birth, 12 echogenic left ventricle papillary muscles and three echogenic left ventricle chordae were identified; there were no postnatal right ventricle findings. There were no cases of intracardiac tumor or myocardial dysfunction; one neonate had minor structural malformations. There were no significant differences in maternal age, gravidity, parity, gestational age at ultrasonography, gestational age at delivery, or 5-minute Apgar scores. A significant difference was observed in birth weight between the control (n = 50) and study (n = 25) groups (3465 +/- 501 gm vs 3124 +/- 589 gm; p = 0.002). This difference persisted after correcting for gestational age, although all infants in both groups born after 37.0 weeks weighed > 2500 gm. CONCLUSIONS The incidence of echogenic cardiac foci during routine midtrimester ultrasonography is 4.9%. As an isolated finding, the echogenic cardiac focus may be associated with a statistically significant but clinically insignificant decrease in birth weight. Because of these findings, we consider an isolated echogenic cardiac focus in a patient at low risk for cardiac abnormalities a variant of normal, which does not warrant follow-up clinical evaluation.
Collapse
|
127
|
Dildy GA, Jackson GM, Fowers GK, Oshiro BT, Varner MW, Clark SL. Very advanced maternal age: pregnancy after age 45. Am J Obstet Gynecol 1996; 175:668-74. [PMID: 8828432 DOI: 10.1053/ob.1996.v175.a74402] [Citation(s) in RCA: 95] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
OBJECTIVE Our purpose was to describe the maternal and fetal outcomes of pregnancies in women > or = 45 years old at delivery. STUDY DESIGN A retrospective review of in-hospital deliveries after 20 weeks of gestation was performed in four Utah tertiary care hospitals for the 10-year period between 1985 and 1994. RESULTS Seventy-nine cases were identified among 126,500 births, with an incidence of 0.63 per 1000 births. Maternal ages were 45 (n = 44), 46 (n = 21), and > or = 47 (n = 14) years. Three of the conceptions were assisted, including both twin gestations. Thirty-seven (46.8%) had obstetric complications during pregnancy; the most frequent complications were gestational diabetes (12.7%) and preeclampsia (10.1%). Median (range) gestational age at delivery was 39 (22.9 to 41.7) weeks; 12 (15.2%) deliveries occurred before 37 weeks. Eight (9.9%) karyotype abnormalities were diagnosed. The cesarean section rate was 31.7%; the most frequent indications were abnormal lie (n = 9), fetal distress (n = 5), and previous cesarean delivery (n = 5). There were no maternal deaths. Median (range) birth weight was 3466 (397 to 5085) gm; 14 (17.3%) were < 2500 gm and 16 (19.8%) were > 4000 gm. Twelve (14.8%) infants were admitted to the neonatal intensive care unit. The corrected perinatal mortality rate was 1.3% (1/78). CONCLUSIONS In women > 45 years old at delivery maternal and fetal outcomes were generally good, but there was a high incidence of pregestational (chronic hypertension, hypothyroidism) and gestational (karyotype abnormalities, gestational diabetes, cesarean section, macrosomia) complications. This information may be helpful for counseling women between 45 and 50 years old who are considering pregnancy.
Collapse
|
128
|
Dildy GA, Thorp JA, Yeast JD, Clark SL. The relationship between oxygen saturation and pH in umbilical blood: implications for intrapartum fetal oxygen saturation monitoring. Am J Obstet Gynecol 1996; 175:682-7. [PMID: 8828434 DOI: 10.1053/ob.1996.v175.a74922] [Citation(s) in RCA: 69] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
OBJECTIVE Our purpose was to evaluate the relationship between umbilical arterial blood oxygen saturation determined by hemoximetry (Sao2) and umbilical arterial blood pH and base excess determined by blood gas analysis to establish a "critical threshold" for fetal preductal arterial oxygen saturation determined by reflectance pulse oximetry (Spo2). STUDY DESIGN Umbilical artery and vein blood specimens were obtained at delivery. Blood gas analysis and hemoximetry were performed. Polynomial regression analysis and receiver-operator characteristic curves were calculated for umbilical arterial blood Sao2 and theoretic preductal arterial blood Sao2 versus umbilical arterial blood pH and base excess. RESULTS A total of 1101 paired umbilical artery and vein specimens were obtained. When the umbilical arterial blood Sao2 was > or = 30%, umbilical arterial blood pH was > or = 7.13 in 99.0% (388/392) of cases and < 7.13 in 1.0% (4/392) of cases. When umbilical arterial blood Sao2 was < 30%, umbilical arterial blood pH was > or = 7.13 in 91.4% (648/709) of cases and < 7.13 in 8.6% (61/709) of cases. CONCLUSIONS From these analyses, it appears that an Spo2 cutoff value of 30% would be reasonable in clinical trials of intrapartum fetal pulse oximetry.
Collapse
|
129
|
Hankins GD, Harvey CJ, Clark SL, Uckan EM, Van Hook JW. The effects of maternal position and cardiac output on intrapulmonary shunt in normal third-trimester pregnancy. Obstet Gynecol 1996; 88:327-30. [PMID: 8752233 DOI: 10.1016/0029-7844(96)00212-8] [Citation(s) in RCA: 22] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
OBJECTIVE To assess the effect of pregnancy, maternal position, and cardiac output on intrapulmonary shunting (Qs/Qt) in normotensive nulliparous women near term. METHODS Ten normotensive nulliparas between 36 and 38 weeks' gestation underwent pulmonary artery catheterization (via the subclavian route) and radial artery canalization. Baseline assessments were made with subjects in the left lateral recumbent position after a 30-minute stabilization period. Measurements were obtained sequentially in the left lateral, right lateral, supine, knee-chest, sitting, and standing positions. Each position change was followed by a 10-minute pre-measurement stabilization period. Cardiac output was measured via the thermodilution technique. Blood samples were obtained simultaneously from the pulmonary and radial arteries and analyzed in duplicate for oxygen content with a blood gas analyzer. Qs/Qt was calculated using the classic shunt equation. Statistical analysis was performed by analysis of variance of repeated measures of Qs/Qt and maternal position. The relationship of Qs/Qt to maternal cardiac output was evaluated by the correlation coefficient. Significance was defined as P < .05. RESULTS Directly measured Qs/Qt averaged 15.3% in left lateral, 15.2% in right lateral, 13.9% in supine, 12.8% in knee-chest, 13.8% in sitting, and 13.0% in standing positions. There was no statistically significant correlation between Qs/Qt and cardiac output (R2 = 0.11, not significant). CONCLUSION This is the first report of directly measured Qs/Qt in normal pregnant women in the third trimester. Qs/Qt values reported in pregnancy are higher than those reported in nonpregnant individuals.
Collapse
|
130
|
Hankins GD, Clark SL, Harvey CJ, Uckan EM, Cotton D, Van Hook JW. Third-trimester arterial blood gas and acid base values in normal pregnancy at moderate altitude. Obstet Gynecol 1996; 88:347-50. [PMID: 8752237 DOI: 10.1016/0029-7844(96)00210-4] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
OBJECTIVE To report arterial blood gas and acid base values of normal nulliparous patients at moderate altitude for commonly used maternal positions. METHODS Ten normotensive nulliparous women between 36 and 38 weeks' gestation volunteered to undergo radial and pulmonary artery cannulation as part of a larger study. Following instrumentation, baseline assessments were made in the left lateral recumbent position after a 30-minute stabilization period. Sequential measurements were then obtained in the left lateral, right lateral, supine, knee-chest, sitting, and standing positions. Blood samples were analyzed in duplicate for oxygen content on a blood gas analyzer. Statistical analysis was performed by analysis of variance of repeated measures with significance defined at P < or = .05. RESULTS There was no significant difference in arterial blood gas or acid base values between any positions in this antepartum population of term healthy women. The composite mean values were as follows: pH 7.46, arterial carbon dioxide pressure (PaCO2) 26.6 mmHg, arterial oxygen pressure 88.3 mmHg, bicarbonate 18.2 mEq/L, saturated arterial hemoglobin level 0.96. CONCLUSION Arterial blood gas and acid base values are not altered by maternal position in the late third trimester of pregnancy. The PaO2 in these women studied at moderate altitude was lower than previously reported for healthy pregnant women studied at sea level. Appropriate interpretation of arterial blood specimens of pregnant women should take into account both the pregnancy and altitude at which the women reside.
Collapse
|
131
|
Abstract
Oxygen saturation monitoring (pulse oximetry) has markedly improved medical care in many fields, including anesthesiology, critical care, and newborn intensive care. In obstetrics, fetal heart rate monitoring remains the standard for intrapartum assessment of fetal well-being. Fetal heart rate monitoring is sensitive but nonspecific for detecting fetal compromise. Additional clinical information is needed to discern those fetuses not at risk for development of intrapartum acidosis to avoid unnecessary intervention. Fetal oxygen saturation monitoring is a new technique currently under development. This article reviews the evolution of intrapartum fetal oxygen saturation monitoring and proposes directions for future investigation.
Collapse
|
132
|
Porter TF, Dildy GA, Blanchard JR, Kochenour NK, Clark SL. Normal values for amniotic fluid index during uncomplicated twin pregnancy. Obstet Gynecol 1996; 87:699-702. [PMID: 8677069 DOI: 10.1016/0029-7844(96)00006-3] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
OBJECTIVE To establish the gestational age trends of amniotic fluid index (AFI) in uncomplicated twin pregnancies. METHODS Amniotic fluid index was measured in uncomplicated twin pregnancies seen between 1985 and 1993 and meeting the following criteria: 1) no maternal medical or obstetric complications, 2) normal growth of both twins by serial ultrasound, and 3) normal amniotic fluid volume by ultrasound. Amniotic fluid index was measured by adding the deepest vertical pockets in four quadrants, defined by the umbilicus and linea nigra. The relation between gestational age and AFI was evaluated using linear regression analysis. RESULTS Two hundred eighty-two sets of twins were considered uncomplicated; 1101 AFI measurements were performed on these pregnancies between 25.5 and 40.5 weeks' gestation. Percentile values for AFI were determined according to gestational age. The regression equation relating the median AFI to gestational age was: AFI = 19.4 - 0.12 x gestational age (P = .03). The R2 value was 0.04. CONCLUSION Gestational age trends in normative AFI measurements for twin pregnancies have been established. Their use will facilitate a more reproducible, quantitative diagnosis of oligohydramnios in twins, compared with subjective, qualitative approaches to amniotic fluid volume assessment.
Collapse
|
133
|
Dizon-Townson D, Kennedy KA, Dildy GA, Wu J, Egger M, Clark SL. Amniotic fluid index and perinatal morbidity. Am J Perinatol 1996; 13:231-4. [PMID: 8724725 DOI: 10.1055/s-2007-994370] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
Our purpose was: (1) to determine whether assessment of amniotic fluid index in high risk patients with a reactive nonstress test (NST) allowed improved recognition of the fetus at risk for perinatal morbidity than a reactive NST alone; and (2) to determine the optimal low amniotic fluid index (AFI) which should prompt clinical concern. The last NST performed within a week of delivery and amniotic fluid index were retro-spectively compared with various indices of perinatal morbidity. In fetuses with a reactive NST, decreasing AFI was directly correlated with a risk of 5-minute Apgar score of less than 7 and delivery for fetal distress. When various subgroupings of AFI were compared, 7 cm or greater appeared to have a better inverse correlation with the indices of morbidity than lower cut-off values. The addition of AFI assessment to the standard NST allows better prediction of perinatal morbidity than the NSTs alone. Seven centimeters appears to be a reasonable cut-off for clinical concern.
Collapse
|
134
|
Varner MW, Dildy GA, Hunter C, Dudley DJ, Clark SL, Mitchell MD. Amniotic fluid epidermal growth factor levels in normal and abnormal pregnancies. JOURNAL OF THE SOCIETY FOR GYNECOLOGIC INVESTIGATION 1996; 3:17-9. [PMID: 8796801 DOI: 10.1016/1071-5576(95)00044-5] [Citation(s) in RCA: 20] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
OBJECTIVE To determine the concentrations of epidermal growth factor (EGF) in amniotic fluid (AF) from women during late pregnancy, with and without pathophysiologic complications. METHODS All AFs were collected by amniocentesis from the following groups: gestational age at least 38 weeks (n = 15); gestational age 36-37 weeks (n = 10); gestational age 35 weeks (n = 5); labor 34 weeks or less, delivered within 7 days (n = 10); labor 34 weeks or less, undelivered (n = 10); chorioamnionitis (n = 7); gestational age-matched controls (n = 7); term, in labor (n = 8); term, not in labor (n = 8); intrauterine growth restriction (IUGR) 38 weeks or more (n = 8); macrosomia at 38 weeks or more (n = 10). Epidermal growth factor was assayed using a specific radioimmunoassay. RESULTS Amniotic fluid EGF levels increase rapidly in late pregnancy but are not altered by chorioamnionitis or by term or preterm labor. Intrauterine growth restriction is associated with lower EGF levels in AF, but macrosomia is without effect. CONCLUSIONS Epidermal growth factor levels in AF are increased near term and decreased in pregnancies complicated by IUGR; they may be an indicator of specific maturational events.
Collapse
|
135
|
Dildy GA, Clark SL. Cardiac arrest during pregnancy. Obstet Gynecol Clin North Am 1995; 22:303-14. [PMID: 7651673] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
Cardiac arrest occurs rarely in pregnancy. Nevertheless, the practicing obstetrician stands a likely chance of encountering this acute condition at least once over the course of a busy career. A basic understanding of maternal-fetal physiology and the acute management of cardiac arrest are of key importance. ECC is not significantly changed from that administered to the nonpregnant patient. Factors unique to pregnancy, however, such as lateral uterine displacement, effects of drugs on the mother and the fetus, and the issues of perimortem cesarean section should be understood by the consulting obstetrician. The critical period in management of these patients is within the first several minutes of the event. In many situations, the obstetrician may be the first to arrive and initiate therapy before the arrival of multidisciplinary assistance. Prompt initial management will give the mother and fetus the best chances for survival.
Collapse
|
136
|
Dildy GA, Clark SL, Loucks CA. Reply. Am J Obstet Gynecol 1995. [DOI: 10.1016/0002-9378(95)91440-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
137
|
Clark SL, Hankins GD, Dudley DA, Dildy GA, Porter TF. Amniotic fluid embolism: analysis of the national registry. Am J Obstet Gynecol 1995; 172:1158-67; discussion 1167-9. [PMID: 7726251 DOI: 10.1016/0002-9378(95)91474-9] [Citation(s) in RCA: 528] [Impact Index Per Article: 18.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
OBJECTIVE We analyzed the clinical course and investigated possible pathophysiologic mechanisms of amniotic fluid embolism. STUDY DESIGN We carried out a retrospective review of medical records. Forty-six charts were analyzed for 121 separate clinical variables. RESULTS Amniotic fluid embolism occurred during labor in 70% of the women, after vaginal delivery in 11%, and during cesarean section after delivery of the infant in 19%. No correlation was seen with prolonged labor or oxytocin use. A significant relation was seen between amniotic fluid embolism and male fetal sex. Forty-one percent of patients gave a history of allergy or atopy. Maternal mortality was 61%, with neurologically intact survival seen in 15% of women. Of fetuses in utero at the time of the event, only 39% survived. Clinical and hemodynamic manifestations were similar to those manifest in anaphylaxis and septic shock. CONCLUSIONS Intact maternal or fetal survival with amniotic fluid embolism is rare. The striking similarities between clinical and hemodynamic findings in amniotic fluid embolism and both anaphylaxis and septic shock suggest a common pathophysiologic mechanism for all these conditions. Thus the term amniotic fluid embolism appears to be a misnomer.
Collapse
|
138
|
Liao JK, Clark SL. Regulation of G-protein alpha i2 subunit expression by oxidized low-density lipoprotein. J Clin Invest 1995; 95:1457-63. [PMID: 7706449 PMCID: PMC295627 DOI: 10.1172/jci117816] [Citation(s) in RCA: 59] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023] Open
Abstract
Oxidized low-density lipoprotein (LDL) inhibits signalling pathways mediated by pertussis toxin-sensitive guanine nucleotide-binding proteins (Gi proteins). To determine whether this inhibition is due to altered G protein alpha i subunit expression, mRNA and protein levels of alpha i isoforms were assessed in bovine aortic endothelial cells treated with oxidized LDL (0-100 micrograms/ml, 0-72 h). Oxidized LDL did not affect the expression of alpha i3, but did cause time- and concentration-dependent decrease in alpha i2 mRNA and protein resulting in a 3.2- and 3.5-fold reduction, respectively, after 72 h. This decrease in alpha i2 coincided with a 86% decrease in alpha i2 GTPase activity. Nuclear run-off studies did not show any significant effect of oxidized LDL on alpha i2 or alpha i3 transcription. In the presence of actinomycin D, oxidized LDL shortened the t1/2 of alpha i2 mRNA from 16 h to 8 h which was attenuated by cycloheximide. In addition, pulse-chase labelling with [35S]methionine revealed that oxidized LDL reduced the t1/2 of alpha i2 protein from 27 to 14 h. Our results indicate that oxidized LDL can modulate receptor-Gi coupling by downregulating the expression of alpha i2, but not alpha i3. The mechanism involves both mRNA destabilization and protein degradation.
Collapse
|
139
|
Liao JK, Shin WS, Lee WY, Clark SL. Oxidized low-density lipoprotein decreases the expression of endothelial nitric oxide synthase. J Biol Chem 1995; 270:319-24. [PMID: 7529227 DOI: 10.1074/jbc.270.1.319] [Citation(s) in RCA: 402] [Impact Index Per Article: 13.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023] Open
Abstract
The atherogenic effects of low-density lipoprotein (LDL) may be mediated, in part, by its effect(s) on endothelial-derived nitric oxide (NO). To determine whether LDL can modulate NO production by changing NO synthase expression, we treated human saphenous vein endothelial cells with increasing concentrations of native or oxidized LDL (0-100 micrograms/ml) for various durations (0-72 h). Oxidized, but not native LDL caused a time-dependent decrease in steady-state NO synthase mRNA levels. This coincided with a maximal 56% decrease in NOS activity was determined by [3H]arginine to [3H]citrulline conversion. In the presence of actinomycin D, treatment with oxidized LDL reduced the half-life of NO synthase mRNA from 36 to 10 h. This decrease in NO synthase mRNA correlated with the degree of LDL oxidation and was attenuated by pretreatment with cycloheximide. Nuclear run-off studies showed a biphasic transcriptional pattern of NO synthase gene with an initial 25% decrease during the first 6 h followed by a maximal 2.2-fold increase over baseline during the subsequent 18 h. These results indicate that oxidized LDL regulates endothelial NOS expression through a combination of early transcriptional inhibition and post-transcriptional mRNA destabilization.
Collapse
|
140
|
Kennedy KA, Clark SL. Factors Influencing Pain Associated with Amniocentesis Before 25 Weeks Gestation. J Matern Fetal Neonatal Med 1995. [DOI: 10.3109/14767059509017313] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
141
|
Hankins GD, Clark SL. Brachial plexus palsy involving the posterior shoulder at spontaneous vaginal delivery. Am J Perinatol 1995; 12:44-5. [PMID: 7710576 DOI: 10.1055/s-2007-994398] [Citation(s) in RCA: 41] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
Brachial plexus injuries sustained at birth have most often been attributed to the maneuvers performed when attempting to relieve a shoulder dystocia or to deliver a breech vaginally. In the case now reported, the brachial plexus injury involved the posterior shoulder. As the delivery was spontaneous and without forceps or manual rotation, with delivery effected using only the McRobert's maneuver, it is hypothesized that maternal expulsive forces in conjunction with lodging of the posterior shoulder on the sacral promontory resulted in the injury.
Collapse
|
142
|
Dildy GA, Clark SL, Loucks CA. Intrapartum fetal pulse oximetry: the effects of maternal hyperoxia on fetal arterial oxygen saturation. Am J Obstet Gynecol 1994; 171:1120-4. [PMID: 7943083 DOI: 10.1016/0002-9378(94)90048-5] [Citation(s) in RCA: 50] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
OBJECTIVE Our purpose was to observe the effects of maternal oxygen administration on fetal arterial oxygen saturation in normal human fetuses during labor. STUDY DESIGN Twenty healthy women with uncomplicated pregnancies were studied during active labor at term. Arterial oxygen saturation was measured by a noninvasive reflectance pulse oximeter designed for fetal application (Nellcor, Inc, Pleasanton, Calif.). The first group was studied during 20-minute intervals of inspired oxygen concentrations of 21%, 40%, and 100%. In a second group the effects of prolonged (45 minutes) supplemented 40% oxygen administration were evaluated. Differences between groups were analyzed by analysis of variance; significance was considered at p < 0.05. RESULTS A significant increase in fetal arterial oxygen saturation (50% +/- 8% vs 64% +/- 6%, p < 0.0001) was detected in the group given 100% oxygen for 20 minutes but not in the groups that received 40% oxygen for 20 or 45 minutes. CONCLUSIONS Prolonged maternal administration of 40% oxygen resulted in no significant demonstrable change in fetal arterial oxygen saturation determined by reflectance pulse oximetry in normal fetuses. Because the administration of oxygen by standard mask techniques rarely results in 40% inspired oxygen concentration, fetal benefits of such intrapartum maternal oxygen administration are questionable.
Collapse
|
143
|
Dildy GA, van den Berg PP, Katz M, Clark SL, Jongsma HW, Nijhuis JG, Loucks CA. Intrapartum fetal pulse oximetry: fetal oxygen saturation trends during labor and relation to delivery outcome. Am J Obstet Gynecol 1994; 171:679-84. [PMID: 8092214 DOI: 10.1016/0002-9378(94)90081-7] [Citation(s) in RCA: 97] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
OBJECTIVES Our purpose was to study fetal arterial oxygen saturation trends by continuous pulse oximetry during labor in subjects with normal and abnormal delivery outcomes. STUDY DESIGN Continuous fetal arterial oxygen saturation was measured during labor with a noninvasive reflectance pulse oximeter designed for fetal application. Averaged arterial oxygen saturation values were compared between stage 1 and stage 2 of labor, with stage 1 further subdivided into early (< or = 4 cm), middle (5 to 7 cm), and late (8 to 10 cm) phases. Delivery outcome was considered to be abnormal for any of the following conditions: gestational age < 37 weeks, maternal oxygen administration, delivery by cesarean section, 5-minute Apgar score < 7, umbilical artery pH < 7.10, birth weight < 2500 gm, or newborn intensive care unit admission. RESULTS A total of 291 subjects were studied: 142 in Provo, 90 in Nijmegen and 59 in San Francisco. Subjects with delivery complications (n = 125) were evaluated separately from those with normal delivery outcomes (n = 160). Fetal arterial oxygen saturation was 58% +/- 10% (mean +/- SD) during the cumulative period of study for the normal-outcome group. A significant decrease (paired t test, p < 0.001) in fetal arterial oxygen saturation occurred from stage 1 (59% +/- 10%) to stage 2 (53% +/- 10%) labor. When stage 1 was subdivided into early (< or = 4 cm), middle (5 to 7 cm), and late (8 to 10 cm) phases, a gradual decreasing trend in fetal arterial oxygen saturation was observed: 62% +/- 9%, 60% +/- 11%, and 58% +/- 10%. CONCLUSIONS With the use of reflectance pulse oximetry, a statistically significant decrease in fetal arterial oxygen saturation was observed during labor in women with normal and abnormal delivery outcomes.
Collapse
|
144
|
|
145
|
Clark SL, Southwick J, Pivarnik JM, Cotton DB, Hankins GD, Phelan JP. A comparison of cardiac index in normal term pregnancy using thoracic electrical bio-impedance and oxygen extraction (Fick) techniques. Obstet Gynecol 1994; 83:669-72. [PMID: 8164923] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
OBJECTIVE To correlate cardiac index in normal late third-trimester pregnancy using the thoracic electrical bio-impedance technique with that obtained from the oxygen extraction technique. METHODS Eight carefully screened normal pregnant women underwent assessment of cardiac index using both the thoracic electrical bio-impedance technique and the oxygen extraction technique. Measurements were obtained in various positions. RESULTS The correlation was good between the thoracic electrical bio-impedance and oxygen extraction techniques in the left lateral (r = 0.915) and right lateral (r = 0.863) positions, and the intercepts at the midpoints of the oxygen extraction data in these positions suggested good absolute correlation as well. Correlation between thoracic electrical bio-impedance and the Fick cardiac index was poor in all other positions. CONCLUSIONS Thoracic electrical bio-impedance cardiac index assessment is influenced by maternal position and must be used with caution in clinical research protocols. This technique appears to be inappropriate for general clinical use during pregnancy.
Collapse
|
146
|
Dildy GA, Loucks CA, Clark SL. Intrapartum fetal pulse oximetry in the presence of fetal cardiac arrhythmia. Am J Obstet Gynecol 1993; 169:1609-11. [PMID: 8267071 DOI: 10.1016/0002-9378(93)90446-p] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
We report our experience with a reflectance pulse oximeter in intrapartum monitoring of a fetus with atrial flutter and heart block. During labor fetal arterial oxygen saturation ranged between 50% and 85%. Spontaneous vaginal delivery occurred with good maternal and neonatal outcome.
Collapse
|
147
|
Clark SL. Asthma in pregnancy. National Asthma Education Program Working Group on Asthma and Pregnancy. National Institutes of Health, National Heart, Lung and Blood Institute. Obstet Gynecol 1993; 82:1036-40. [PMID: 8233255] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
This manuscript is a summary of a comprehensive report dealing with asthma and pregnancy issued by the working group on Asthma and Pregnancy, National Institutes of Health (NIH), National Heart, Lung, and Blood Institute. The report was developed by a panel of obstetricians, pharmacologists, internists, allergists, and pulmonologists, who met over an 18-month period under the auspices of the NIH. Undertreatment of pregnant asthmatics, partially because of unfounded fears of adverse pharmacologic effects on the developing fetus, remains the major problem in the management of asthma during pregnancy in the United States. The four key components of asthma management during pregnancy are: 1) objective assessment of maternal lung function and fetal well-being, 2) avoidance or control of environmental precipitating factors, 3) pharmacologic therapy, and 4) patient education.
Collapse
|
148
|
Jackson GM, Dildy GA, Varner MW, Clark SL. Severe pulmonary hypertension in pregnancy following successful repair of ventricular septal defect in childhood. Obstet Gynecol 1993; 82:680-2. [PMID: 8378010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
BACKGROUND Because of advances in surgical repair, an increasing number of women born with structural cardiac disease now live to reproductive age. Patients treated successfully in childhood are followed for varying periods of time, then may be lost to follow-up or told that no follow-up is necessary because their condition is stable. However, the hemodynamic changes that accompany pregnancy may result in cardiovascular decompensation, even after years of apparently good health. CASES We have recently cared for two women who had undergone repair of congenital heart disease in childhood. Although they thought that their repair was complete and they had been asymptomatic until the pregnancy, both presented with symptoms and signs of severe pulmonary hypertension, subsequently confirmed on cardiac catheterization. One patient elected to terminate her pregnancy, and the other died in the immediate puerperium. CONCLUSION Despite normal physical function and an absence of abnormal physical findings, a thorough cardiac evaluation including echocardiography should be considered for pregnant patients with a history of repaired congenital heart disease, especially if the original defect is known to lead to pulmonary hypertension.
Collapse
|
149
|
Hankins GD, Snyder RR, Clark SL, Schwartz L, Patterson WR, Butzin CA. Acute hemodynamic and respiratory effects of amniotic fluid embolism in the pregnant goat model. Am J Obstet Gynecol 1993; 168:1113-29; discussion 1129-30. [PMID: 8475957 DOI: 10.1016/0002-9378(93)90355-m] [Citation(s) in RCA: 55] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
OBJECTIVE Our purpose was to determine the acute-phase central hemodynamic and respiratory effects of raw, filtered, filtered and boiled, and meconium-containing amniotic fluid. STUDY DESIGN Pregnant goats (Capra hircus) in the last one third of pregnancy were given freshly collected autologous amniotic fluid in a volume of 2.5 ml/kg of body weight. Observations were then made at 10, 30, 60, 120, and 180 minutes after amniotic fluid embolism. Pulmonary artery catheters and femoral artery lung water catheters were placed for specimen and data collection. RESULTS Marked pressor responses were observed in both the pulmonary and systemic circulations with all amniotic fluid infusions. The pressor response was similar with raw, filtered, and filtered and boiled amniotic fluid. The pressor response seen with amniotic fluid containing meconium was significantly greater than that seen with the other forms. No significant effects were observed on cardiac or respiratory function except in the meconium group, where transient left ventricular dysfunction was accompanied by an acute increase in extravascular lung water and dysoxia. CONCLUSIONS The Capra hircus model is appropriate for the further study of amniotic fluid embolism. The acute pressor effects are transient and involve both the systemic and pulmonary circulations. Left ventricular dysfunction and dysoxia were observed only with embolism of amniotic fluid containing meconium.
Collapse
|
150
|
Dildy GA, Clark SL, Loucks CA. Preliminary experience with intrapartum fetal pulse oximetry in humans. Obstet Gynecol 1993; 81:630-5. [PMID: 8459982] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
Electronic fetal heart rate (FHR) monitoring is commonly used to assess fetal well-being during labor. Nonreassuring patterns in many cases are associated with normal fetal acid-base condition, leading to unnecessary operative intervention. Fetal pulse oximetry has several potential advantages over FHR monitoring because it assesses not only pulse, but also arterial oxygen saturation and tissue perfusion. We describe our preliminary experience with the Nellcor N-400 Fetal Oxygen Saturation Monitor and FS-10 Oxisensor in 73 subjects during active labor at term. The mean (+/- standard deviation) duration of monitoring was 161.4 +/- 106.0 minutes, with sensor contact achieved 67.3 +/- 22.5% of the time during labor. Data were successfully recorded in all patients, with a reliable signal obtained 50.1 +/- 21.6% of the time during labor. The mean fetal oxygen saturation was 57.9 +/- 10.0%. The potential for research and clinical applications appears promising with further sensor and monitor development.
Collapse
|