51
|
Perazzini C, Compagnone L, Chabrot P, Boyer L, Puechmaille M, Mom T. A case of cochlear-facial dehiscence revealed after bilateral cochlear implants. Radiol Case Rep 2024; 19:1110-1117. [PMID: 38229606 PMCID: PMC10789939 DOI: 10.1016/j.radcr.2023.11.083] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2023] [Revised: 11/16/2023] [Accepted: 11/30/2023] [Indexed: 01/18/2024] Open
Abstract
The cochlear implant is an implanted auditory prosthesis that can restore severe and profound hearing loss. About 20% of patients with congenital sensorineural hearing loss have a malformation of the inner ear. These abnormalities must be investigated before a cochlear implant because they can lead to intra and postoperative complications and/or anomalies. Most labyrinthine malformations are well known; some are less frequent and can be underdiagnosed at the preoperative computed tomography. This report presents the case of bilateral cochlear-facial dehiscence, bony dehiscence between the facial nerve labyrinthine segment, and cochlear basal turn. In our 56-year-old patient, this malformation was misdiagnosed before the cochlear implant and revealed afterward because of abnormal facial nerve stimulation during intraoperative electrophysiological checking.
Collapse
|
52
|
Yano T, Tomioka R, Shirai K, Nishiyama N, Tsukahara K. Listening evaluation of cochlear implant users: comparison of subjective and objective evaluation by visual analogue scale. J Laryngol Otol 2024; 138:297-300. [PMID: 37646292 PMCID: PMC10876450 DOI: 10.1017/s0022215123001445] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2023] [Revised: 06/15/2023] [Accepted: 07/18/2023] [Indexed: 09/01/2023]
Abstract
OBJECTIVE This study aimed to use short-form visual analogue scale cochlear implantation questionnaires to evaluate subjective aspects at each out-patient visit. The correlation between subjective hearing tests using the short-form visual analogue scale and objective hearing outcomes was evaluated. METHOD This study was conducted in a single centre. Cochlear implant users (n = 199) evaluated their hearing on a scale of 0 to 100 for the right, left and both ears. The Japanese speech perception test (CI-2004) Japanese monosyllable speech perception test (67-S) and cochlear implantation threshold were used for the objective cochlear implantation evaluation. RESULTS A significant correlation was found between the short-form visual analogue scale questionnaire and objective hearing outcome, for words (r = 0.64) and sentences (r = 0.62) in CI-2004 and 67-S (r = 0.56) tests. No significant correlation was found between the short-form visual analogue scale score and cochlear implantation threshold (r = -0.18). CONCLUSION Short-form visual analogue scale cochlear implantation questionnaires mean cochlear implant users spend less time answering subjective visual analogue scale questionnaires, and clinicians estimate a patient's cochlear implantation hearing and abnormality by chronological evaluation.
Collapse
|
53
|
Munhall CC, Roberts DR, Labadie RF. The Use of Portable, Very Low-field (0.064T) MRI to Image Cochlear Implants: Metallic Image Artifact in Comparison to Traditional, Stationary 3T MRI. OTOLOGY & NEUROTOLOGY OPEN 2024; 4:e049. [PMID: 38533347 PMCID: PMC10962874 DOI: 10.1097/ono.0000000000000049] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/14/2023] [Accepted: 01/08/2024] [Indexed: 03/28/2024]
Abstract
Objective To assess image artifact when imaging a cochlear implant (CI) with a conventional 3T MRI machine compared with a very low-field (0.064T) MRI. Patients None. Intervention Diagnostic study. Main Outcome Measure Image artifact size associated with the CI affixed to an MRI phantom at very low-field 0.064T MRI versus 3T MRI. Results The longest diameter of the image artifact was 125 mm for the 3T MRI and 86 mm for the 0.064T MRI, representing 45% longer image artifact generated in the 3T MRI. The actual volume of the imaging phantom was 1371 cm3. The volume of the image artifact was measured as 379 cm3 in the 3T MRI, representing a loss of 27.6% of the actual volume of the imaging phantom. The volume of image artifact was measured as 170 cm3 in the 0.064T MRI, representing a loss of 12.4% of the phantom volume. Conclusions 3T MRI had better image quality. This result was not surprising given that larger magnetic field strength is known to provide higher resolution. There was 15% less image artifact generated in the very low-field MRI machine compared with a conventional 3T device. And there was also subjectively increased distortion of the imaging phantom at 3T MRI compared with the 0.064T MRI. With minimized safety concerns and a much lower cost than conventional 3T machines, very low-field scanners may find expanded clinical uses. This preclinical study explores the potential utility of very low-field MRI in scanning CI recipients.
Collapse
|
54
|
Wang B, Guo X, Wei C, Cao K. Preoperative EABR evaluation of auditory pathway integrity in patients with different etiology and postoperative effect estimation. Eur Arch Otorhinolaryngol 2024; 281:1185-1193. [PMID: 37615702 DOI: 10.1007/s00405-023-08198-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2023] [Accepted: 08/17/2023] [Indexed: 08/25/2023]
Abstract
OBJECTIVES To evaluate the effect of electrical auditory brainstem response (EABR) on the integrity evaluation of auditory pathway and the prediction of postoperative effect of cochlear implantation in patients with different etiology of hearing loss. METHODS A total of 580 patients with neuropathic deafness who underwent cochlear implantation surgery from August 2011 to December 2020 were selected for EABR test. The preoperative EABR waveform was analyzed, and parameters such as V wave amplitude, threshold, latency and interval of each wave, and slope of V wave I/O curve were measured. Neural response telemetry (NRT) test was performed during MAP 1 month after operation, and C and T values of the machine were recorded. RESULTS The total EABR extraction rate was 98.45% among 580 patients, including 100% for the normal structure group and enlarged vestibular aqueduct group (LVAS), 92.44% for other malformed group. The average threshold of V wave in patients with normal cochlear structure was significantly better than the malformation groups (p < 0.05). The total extraction rate of NRT was 78.62%, including 99.72% in the group with normal structure, 95.65% in the LVAS group, 1.85-88.24% in the group with other malformations, and 0% in the cochlear ossification group. The correlation analysis showed a statistically significant correlation between the average preoperative EABR threshold and the C value of NRT. CONCLUSIONS Preoperative EABR could evaluate the integrity of auditory conduction pathway of patients with cochlear implantation and predict the postoperative hearing rehabilitation effect.
Collapse
|
55
|
Li Z, Zhou L, Bin X, Tan S, Tan Z, Tang A. Utility of deep learning for the diagnosis of cochlear malformation on temporal bone CT. Jpn J Radiol 2024; 42:261-267. [PMID: 37812304 DOI: 10.1007/s11604-023-01494-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2023] [Accepted: 09/19/2023] [Indexed: 10/10/2023]
Abstract
OBJECTIVE Diagnosis of cochlear malformation on temporal bone CT images is often difficult. Our aim was to assess the utility of deep learning analysis in diagnosing cochlear malformation on temporal bone CT images. METHODS A total of 654 images from 165 temporal bone CTs were divided into the training set (n = 534) and the testing set (n = 120). A target region that includes the area of the cochlear was extracted to create a diagnostic model. 4 models were used: ResNet10, ResNet50, SE-ResNet50, and DenseNet121. The testing data set was subsequently analyzed using these models and by 4 doctors. RESULTS The areas under the curve was 0.91, 0.94, 0.93, and 0.73 in ResNet10, ResNet50, SE-ResNet50, and DenseNet121. The accuracy of ResNet10, ResNet50, and SE-ResNet50 is better than chief physician. CONCLUSIONS Deep learning technique implied a promising prospect for clinical application of artificial intelligence in the diagnosis of cochlear malformation based on CT images.
Collapse
|
56
|
Helbig S, Thiemann N, Hattingen E, Loth A, Stöver T, Leinung M. Prospective study on magnetic resonance imaging in cochlear implant patients. Eur Arch Otorhinolaryngol 2024; 281:1231-1242. [PMID: 37707616 PMCID: PMC10858110 DOI: 10.1007/s00405-023-08224-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2023] [Accepted: 09/01/2023] [Indexed: 09/15/2023]
Abstract
PURPOSE Monocentric, prospective study to investigate whether concomitant support of cochlear implant (CI) patients by CI-trained otolaryngologists and application of a standardized head bandage can minimize potential complications during magnetic resonance imaging (MRI). METHODS Thirty-seven patients with 46 CIs underwent MRI with a prophylactic head bandage. All participants and the otolaryngologist at the CI center completed pre- and post-MRI questionnaires documenting body region scanned, duration of MRI and bandage wear, field strength during the scan, and any complications. If pain was experienced, it was assessed using a visual analog scale (1-10). RESULTS MRI was performed without adverse events in 37.8% of cases. Magnet dislocation requiring surgical revision occurred in 2% of cases. Pain was reported in 86% of cases, often due to the tightness of the dressing. Patients with rotating, MRI-compatible magnets reported significantly less pain than participants with older-generation implants. In 11% of cases, the MRI was discontinued. CONCLUSION Serious complications during MRI in cochlear implant patients are rare. Pain is the most common adverse event, probably mainly due to the tight bandage required by most implant types. With newer generations of magnets, these patients experience less pain, no dislocation of the magnets, and no need for bandaging. Although magnet dislocation cannot be completely prevented in older generations of implants, it appears to be reduced by good patient management, which recommends examination under the guidance of physicians trained in the use of hearing implants.
Collapse
|
57
|
Cornwall HL, Lam CM, Chaudhry D, Muzaffar J, Monksfield P, Bance ML. Outcomes of cochlear implantation in Usher syndrome: a systematic review. Eur Arch Otorhinolaryngol 2024; 281:1115-1129. [PMID: 37930386 PMCID: PMC10858075 DOI: 10.1007/s00405-023-08304-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2023] [Accepted: 10/17/2023] [Indexed: 11/07/2023]
Abstract
PURPOSE This study is a systematic review of the literature which seeks to evaluate auditory and quality of life (QOL) outcomes of cochlear implantation in patients with Usher syndrome. METHODS Systematic review of studies indexed in Medline via PubMed, Ovid EMBASE, Web of Science, CENTRAL and clinicaltrials.gov was performed up to March 9th 2022, conducted in accordance with the PRISMA statement. Patient demographics, comorbidity, details of cochlear implantation, auditory, and QOL outcomes were extracted and summarized. RESULTS 33 studies reported over 217 cochlear implants in 187 patients with Usher syndrome, comprising subtypes 1 (56 patients), 2 (9 patients), 3 (23 patients), and not specified (99 patients). Auditory outcomes included improved sound detection, speech perception, and speech intelligibility. QOL outcomes were reported for 75 patients, with benefit reported in the majority. CONCLUSIONS Many patients with Usher syndrome develop improved auditory outcomes after cochlear implantation with early implantation being an important factor.
Collapse
|
58
|
Schauwecker N, Tamati TN, Moberly AC. Predicting Early Cochlear Implant Performance: Can Cognitive Testing Help? OTOLOGY & NEUROTOLOGY OPEN 2024; 4:e050. [PMID: 38533348 PMCID: PMC10962885 DOI: 10.1097/ono.0000000000000050] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/14/2023] [Accepted: 01/08/2024] [Indexed: 03/28/2024]
Abstract
Introduction There is significant variability in speech recognition outcomes in adults who receive cochlear implants (CIs). Little is known regarding cognitive influences on very early CI performance, during which significant neural plasticity occurs. Methods Prospective study of 15 postlingually deafened adult CI candidates tested preoperatively with a battery of cognitive assessments. The mini-mental state exam (MMSE), forward digit span, Stroop measure of inhibition-concentration, and test of word reading efficiency were utilized to assess cognition. consonant-nucleus-consonant words, AZBio sentences in quiet, and AZBio sentences in noise (+10 dB SNR) were utilized to assess speech recognition at 1- and 3-months of CI use. Results Performance in all speech measures at 1-month was moderately correlated with preoperative MMSE, but these correlations were not strongly correlated after correcting for multiple comparisons. There were large correlations of forward digit span with 1-month AzBio quiet (P ≤ 0.001, rho = 0.762) and AzBio noise (P ≤ 0.001, rho = 0.860), both of which were strong after correction. At 3 months, forward digit span was strongly predictive of AzBio noise (P ≤ 0.001, rho = 0.786), which was strongly correlated after correction. Changes in speech recognition scores were not correlated with preoperative cognitive test scores. Conclusions Working memory capacity significantly predicted early CI sentence recognition performance in our small cohort, while other cognitive functions assessed did not. These results differ from prior studies predicting longer-term outcomes. Findings and further studies may lead to better preoperative counseling and help identify patients who require closer evaluation to ensure optimal CI performance.
Collapse
|
59
|
Sahwan M, Abdelsamad Y, Alasfoor F, Alfayez F, Binkhamis G, Nichani J. Cochlear implantation in children with auditory neuropathy spectrum disorder: an updated systematic review. Eur Arch Otorhinolaryngol 2024; 281:1149-1162. [PMID: 37638998 DOI: 10.1007/s00405-023-08194-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2023] [Accepted: 08/14/2023] [Indexed: 08/29/2023]
Abstract
BACKGROUND The goal of managing auditory neuropathy spectrum disorder (ANSD) is to restore the children's ability to discriminate auditory information. Children who are not making sufficient progress in speech comprehension, and speech and language development after receiving adequate auditory re/habilitation and/or acoustic amplification may be candidates for cochlear implantation (CI). Despite the growing number of published literature on CI outcomes in children with ANSD, the current evidence is primarily based on case reports or retrospective chart reviews some of which had a limited number of children. In addition, the outcomes of CI seem to vary between children with ANSD. Thus, compelling evidence is lacking. This updated systematic review evaluated the speech perception, language, and speech intelligibility outcomes of children with ANSD post-CI. METHODS An online bibliographic search was conducted in PubMed, Scopus, Web of Science, and CENTRAL databases. We included both interventional and observational studies that assessed the outcomes of the CI in children with ANSD. RESULTS Thirty-three studies were included in this systematic review. Several tests were used to assess speech perception following CI in children with ANSD. The findings of this study revealed that children with ANSD had mean Categories of Auditory Performance scores ranging from 4.3 to 7 post-operatively, this result was better than the pre-operative scores which ranged between 0.4 to 2.5. Likewise, the Infant-Toddler Meaningful Auditory Integration Scale, Phonetically Balanced Kindergarten, and multisyllabic lexical neighborhood test showed clinically relevant improvement after CI. The same findings were reported for language and speech intelligibility scores. One study investigated the quality of life/children satisfaction after CI and showed overall good satisfaction with the outcomes. CONCLUSIONS The present systematic review suggests that CI is a feasible and effective hearing rehabilitation modality for children with ANSD. REGISTRATION AND PROTOCOL PROSPERO ID: CRD42021279140.
Collapse
|
60
|
Arora K, Plant K, Dawson P, Cowan R. Effect of reducing electrical stimulation rate on hearing performance of Nucleus ® cochlear implant recipients. Int J Audiol 2024:1-10. [PMID: 38420783 DOI: 10.1080/14992027.2024.2314620] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2022] [Accepted: 01/31/2024] [Indexed: 03/02/2024]
Abstract
OBJECTIVE To evaluate whether a 500 pulses per second per channel (pps/ch) rate would provide non-inferior hearing performance compared to the 900 pps/ch rate in the Advanced Combination Encoder (ACE™) sound coding strategy. DESIGN A repeated measures single-subject design was employed, wherein each subject served as their own control. All except one subject used 900 pps/ch at enrolment. After three weeks of using the alternative rate program, both programs were loaded into the sound processor for two more weeks of take-home use. Subjective performance, preference, words in quiet, sentences in babble, music quality, and fundamental frequency (F0) discrimination were assessed using a balanced design. STUDY SAMPLE Data from 18 subjects were analysed, with complete datasets available for 17 subjects. RESULTS Non-inferior performance on all clinical measures was shown for the lower rate program. Subjects' preference ratings were comparable for the programs, with 53% reporting no difference overall. When a preference was expressed, the 900 pps/ch condition was preferred more often. CONCLUSION Reducing the stimulation rate from 900 pps/ch to 500 pps/ch did not compromise the hearing outcomes evaluated in this study. A lower pulse rate in future cochlear implants could reduce power consumption, allowing for smaller batteries and processors.
Collapse
|
61
|
Wesarg T, Kuntz I, Jung L, Wiebe K, Schatzer R, Brill S, Aschendorff A, Arndt S. Masked Speech Perception with Bone Conduction Device, Contralateral Routing of Signals Hearing Aid, and Cochlear Implant Use in Adults with Single-Sided Deafness: A Prospective Hearing Device Comparison using a Unified Testing Framework. Audiol Neurootol 2024:1-19. [PMID: 38387454 DOI: 10.1159/000535383] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2023] [Accepted: 11/19/2023] [Indexed: 02/24/2024] Open
Abstract
INTRODUCTION For the treatment of single-sided deafness (SSD), common treatment choices include a contralateral routing of signals (CROS) hearing aid, a bone conduction device (BCD), and a cochlear implant (CI). The primary aim of this study was to compare speech understanding in noise and binaural benefits in adults with postlingual SSD between preoperative unaided baseline, preoperative CROS and BCD trial devices, and CI, following recommendations from a consensus protocol. In addition, we investigated the effect of masker type on speech understanding. METHODS This was a prospective study with twelve participants. Binaural effects of head shadow, squelch, summation, and spatial release from masking were assessed by measuring speech reception thresholds (SRTs) in five different spatial target-masker configurations using two different maskers: two-talker babble (TTB), and speech-shaped noise (SSN). Preoperatively, participants were assessed unaided and with CROS and BCD trial devices. After cochlear implantation, participants were assessed at 1, 3, and 6 months post-activation. RESULTS For TTB, significant improvements in SRT with a CI relative to preoperatively unaided were found in all spatial configurations. With CI at 6 months, median benefits were 7.8 dB in SSSDNAH and 5.1 dB in S0NAH (head shadow), 3.4 dB in S0N0 (summation), and 4.6 dB in S0NSSD and 5.1 dB in SAHNSSD (squelch). CROS yielded a significant head shadow benefit of 2.4 dB in SSSDNAH and a significant deterioration in squelch of 2.5 dB in S0NSSD and SAHNSSD, but no summation effect. With BCD, there was a significant summation benefit of 1.5 dB, but no head shadow nor squelch effect. For SSN, significant improvements in SRT with CI compared to preoperatively unaided were found in three spatial configurations. Median benefits with CI at 6 months were: 8.5 dB in SSSDNAH and 4.6 dB in S0NAH (head shadow), 1.4 dB in S0N0 (summation), but no squelch. CROS showed a significant head shadow benefit of 1.7 dB in SSSDNAH, but no summation effect, and a significant deterioration in squelch of 2.9 dB in S0NSSD and 3.2 dB in SAHNSSD. With BCD, no binaural effect was obtained. Longitudinally, we found significant head shadow benefits with a CI in SSSDNAH in both maskers at all postoperative intervals and in S0NAH at 3 and 6 months post-activation. CONCLUSION With a CI, a clear benefit for masked speech perception was observed for all binaural effects. Benefits with CROS and BCD were more limited. CROS usage was detrimental to the squelch effect.
Collapse
|
62
|
Bunne M, Myhrum M, Iftikhar M, Rasmussen K, Falkenberg-Jensen B. Cochlear-facial dehiscence - the most common cause of facial nerve stimulation from a cochlear implant? A case-control study. Cochlear Implants Int 2024:1-11. [PMID: 38373739 DOI: 10.1080/14670100.2024.2316452] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/21/2024]
Abstract
OBJECTIVES To investigate the prevalence of cochlear-facial dehiscence (CFD) and other radiographical pathologies in ears with facial nerve stimulation (FNS) from a cochlear implant (CI). METHODS Retrospective case-control study of 27 patients with CI and FNS on either ear (study group) and 27 patients without FNS, matched for age, sex and type of electrode array (control group). Preoperative CT scans of all 108 ears were re-evaluated. Subanalyses included comparisons between the study and control groups and associations between FNS and radiographic pathologies. RESULTS CFDs were detected in 20 of 54 ears (37%) in the study group and in 3 of 54 ears (6%) in the control group (P < 0.001). The corresponding numbers of otosclerosis were 10 (18%) and 0 (P = 0.011) and of developmental anomalies 16 (30%) and 8 (15%) (not significant). FNS was present in 33 ears in the study group, of which 14 (42%) had a CFD. FNS was absent in six ears with CFD and CI, four of which contralateral to an ear with FNS. Eight of 14 ears with FNS and CFD had a lateral electrode array and six had a perimodiolar electrode array. We found no association between the presence of CFD and stimulation thresholds for FNS. The adjusted odds ratio for developing FNS in the presence of a CFD was 9.9 (95% CI 2.7-36.0). CONCLUSIONS CFD was the most common radiographic pathology in ears with FNS, with a 10-fold increased risk of FNS. To avoid CI-related FNS, preoperative CT scan and awareness of typical dehiscence symptoms are strongly recommended.
Collapse
|
63
|
Lehmann EK, Glaubitz C, Heinze-Köhler K, Liebscher T, Hoppe U. Associations between illness perceptions, word recognition, and perceived sound quality in cochlear implant users. Int J Audiol 2024:1-8. [PMID: 38369862 DOI: 10.1080/14992027.2024.2313027] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2022] [Accepted: 01/25/2024] [Indexed: 02/20/2024]
Abstract
OBJECTIVE Illness perceptions refer to thoughts and ideas an individual has about an illness. The aim was to understand how cochlear implant (CI) users' illness perceptions, in addition to their monosyllabic word recognition abilities, are associated with their self-perceived sound quality. DESIGN Data were collected during routine CI check-up appointments. Participants completed the Brief Illness Perception Questionnaire (assessing their illness perceptions) and the Hearing Implant Sound Quality Index (assessing their subjective sound quality). Additionally, monosyllabic word recognition abilities were measured with the Freiburg Monosyllable Word Test. Hierarchical regression analysis were utilised to model users' sound quality ratings. Participants' age was entered first as a control variable. In the next step, monosyllabic word recognition was entered. Finally, participants' illness perceptions were entered. STUDY SAMPLE Fifty-five participants with unilateral CI provision. RESULTS Monosyllabic word recognition was significant in the second step. When illness perceptions and monosyllabic word recognition were both included in the third step, illness perceptions, but not monosyllabic word recognition, were significant. The model explained 22% of the variance of subjective sound quality. CONCLUSIONS Monosyllabic word recognition abilities and illness perceptions of CI users are important for their self-reported sound quality, but illness perceptions appear to be potentially more relevant.
Collapse
|
64
|
Corina DP, Coffey-Corina S, Pierotti E, Mankel K, Miller LM. Electrophysiological study of visual processing in children with cochlear implants. Neuropsychologia 2024; 194:108774. [PMID: 38145800 DOI: 10.1016/j.neuropsychologia.2023.108774] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2023] [Revised: 12/12/2023] [Accepted: 12/19/2023] [Indexed: 12/27/2023]
Abstract
Electrophysiological studies of congenitally deaf children and adults have reported atypical visual evoked potentials (VEPs) which have been associated with both behavioral enhancements of visual attention as well as poorer performance and outcomes in tests of spoken language speech processing. This pattern has often been interpreted as a maladaptive consequence of early auditory deprivation, whereby a remapping of auditory cortex by the visual system ultimately reduces resources necessary for optimal rehabilitative outcomes of spoken language acquisition and use. Making use of a novel electrophysiological paradigm, we compare VEPs in children with severe to profound congenital deafness who received a cochlear implant(s) prior to 31 months (n = 28) and typically developing age matched controls (n = 28). We observe amplitude enhancements and in some cases latency differences in occipitally expressed P1 and N1 VEP components in CI-using children as well as an early frontal negativity, N1a. We relate these findings to developmental factors such as chronological age and spoken language understanding. We further evaluate whether VEPs are additionally modulated by auditory stimulation. Collectively, these data provide a means to examine the extent to which atypical VEPs are consistent with prior accounts of maladaptive cross-modal plasticity. Our results support a view that VEP changes reflect alterations to visual-sensory attention and saliency mechanisms rather than a re-mapping of auditory cortex. The present data suggests that early auditory deprivation may have temporally prolonged effects on visual system processing even after activation and use of cochlear implant.
Collapse
|
65
|
Wang R, Xu K, Luo J, Chao X, Hu F, Zhang D, Chen Y, Li Y, Fan Z, Wang H, Xu L. Vestibular function and hearing preservation in children following a minimally invasive cochlear implantation. Eur Arch Otorhinolaryngol 2024:10.1007/s00405-024-08504-4. [PMID: 38341823 DOI: 10.1007/s00405-024-08504-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2023] [Accepted: 01/24/2024] [Indexed: 02/13/2024]
Abstract
PURPOSE This retrospective cohort study aimed to investigate the effect of minimally invasive cochlear implantation (CI) on the vestibular function (VF) and residual hearing (RH) as well as their relationship in pediatric recipients before and after surgery. METHODS Twenty-four pediatric patients with preoperative low frequency residual hearing (LFRH) (250 or 500 Hz ≤ 80 dB HL) who underwent minimally invasive CI were enrolled. Pure-tone thresholds, the cervical/ocular vestibular-evoked myogenic potential (cVEMP/oVEMP), and video head impulse test (vHIT) were all evaluated in the 24 pediatric patients with preoperative normal VF before and at 1 and 12 months after surgery. The relationship between changes in hearing and VF was analyzed preoperatively and at 1 and 12 months postoperatively. RESULTS There were no significant differences on VF preservation and hearing preservation (HP) at both 1 and 12 months post-CI (p > 0.05). At 1 month post-CI, the correlations of the variations in vestibulo-ocular reflex (VOR) gains of horizontal semicircular canal (HSC) and posterior semicircular canal (PSC) and the shift in 250 Hz threshold were negatively correlated (r = - 0.41, p = 0.04 and r = - 0.43, p = 0.04, respectively). At 12 months post-CI, the shift in 250 Hz threshold negatively correlated to the variations in VOR gain of superior semicircular canal (SSC) (r = - 0.43, p = 0.04); the HP positively correlated to the variation in oVEMP-amplitude ratio (AR) (r = 0.41, p = 0.04). CONCLUSION Our study confirmed that there were partial correlations between VF preservation and HP both in the short- and long-terms after atraumatic CI surgery, especially with the 250 Hz threshold. Regarding the variation of PSC function, the correlation with hearing status was variable with time after atraumatic CI surgery. Minimally invasive techniques for HP are successful and effective for the preservation of VF in pediatric patients both in the short- and long-terms.
Collapse
|
66
|
Herr C, Stöver T, Baumann U, Weissgerber T. Comparison of hearing performance in patients with borderline indication for active middle ear or cochlear implants: clinical outcomes to guide preoperative counseling and decision making. Eur Arch Otorhinolaryngol 2024:10.1007/s00405-024-08491-6. [PMID: 38324057 DOI: 10.1007/s00405-024-08491-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2023] [Accepted: 01/17/2024] [Indexed: 02/08/2024]
Abstract
PURPOSE The aim of the presented study was to compare the audiological benefit achieved in cochlear implant (CI) patients who, in principle, could still have been treated with an active middle ear implant (AMEI) with a group of AMEI users. METHODS Results of 20 CI patients with a pure-tone average (PTA) of 70 dB HL prior to surgery were compared with a group of 12 subjects treated with a Vibrant Soundbridge (VSB). Pre-surgical comparison included PTA for air conduction and bone conduction, maximum speech recognition score for monosyllabic words (WRSmax), and aided monosyllabic word recognition at 65 dB SPL. One year after surgery, aided monosyllabic speech recognition score at 65 dB SPL was compared. RESULTS Mean PTA for air conduction in the VSB group was significantly lower than in the CI group (4.8 dB, Z = - 2.011, p < 0.05). Mean PTA for bone conduction in the VSB group was also significantly lower than in the CI group (23.4 dB, Z = - 4.673, p < 0.001). WRSmax in the VSB group was significantly better than in the CI group (40.7%, Z = - 3.705, p < 0.001). One year after treatment, there was no significant difference in aided speech perception in quiet between both subject groups. CONCLUSION Comparison of the two methods showed equivalent results for both treatments in subjects with a borderline indication. Not only pure-tone audiometry results but, particularly, speech perception scores pre-surgery should be taken into account in preoperative counseling.
Collapse
|
67
|
Nocini R, Soloperto D, Arietti V, De Cecco F, Fulco G, Monzani D, Marchioni D, Sacchetto L. Subtotal Petrosectomy: Pictorial Review of Clinical Indications and Surgical Approach. Indian J Otolaryngol Head Neck Surg 2024; 76:224-236. [PMID: 38440666 PMCID: PMC10909040 DOI: 10.1007/s12070-023-04131-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2023] [Accepted: 07/31/2023] [Indexed: 03/06/2024] Open
Abstract
Subtotal petrosectomy (STP) is characterized by obliteration of the middle ear and occlusion of the external auditory canal. The advent of the endoscope has allowed a reduction in morbidity for some conditions such as cholesteatoma and other middle ear disorders, but STP still plays an important role. A retrospective review of medical records and videos of patients who had undergone STP was performed. Perioperative data and images were collected from various clinical cases who had undergone subtotal petrosectomy at our tertiary referral university hospital in Verona. We confronted our experience with a review of the literature to present the main indications for this type of procedure. STP allows a variety of diseases to be managed effectively as it offers the possibility of a definitive healing with radical clearance of temporal bone. Moreover, it can be safely combined with other procedures with a very low complication rate. Although the endoscope represents a revolution in ear surgery, STP, when indicated, is nowadays a surgical option that should be included in the otosurgeon's portfolio.
Collapse
|
68
|
Asta B, Çinar Sateki N M, Uzdi L N, Tokgöz Yilmaz S. The effect of having a child with hearing impairment on parents. Int J Pediatr Otorhinolaryngol 2024; 177:111864. [PMID: 38237356 DOI: 10.1016/j.ijporl.2024.111864] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/14/2023] [Revised: 12/27/2023] [Accepted: 01/09/2024] [Indexed: 02/12/2024]
Abstract
OBJECTIVE In this study, it was aimed to compare parents of children with hearing impairment (with cochlear implant (CI) or hearing aid) and parents of children with normal hearing (NH) in terms of care burden, self-efficacy and psychological resilience levels. METHODS The study participants were parents of children aged 3-12 years. Zarit Care Burden Scale (ZCBS), Parental Self-Efficacy Scale (PSES) and Brief Psychological Resilience Scale (BPRS) were administered to the parents. RESULTS The mean BPRS score was statistically significantly higher for the NH group than for the hearing impairment groups. It was found that the mean ZCBS score was statistically significantly higher for CI group than for the other groups (p < 0.05). A statistically significant and positive correlation was found between the PSES and BPRS scores of the CI group. CONCLUSION It is thought that the results of this study will contribute to the creation of case-specific intervention/rehabilitation programs.
Collapse
|
69
|
Spiegel JL, Weiss BG, Mueller J, Hempel JM, Rader T, Bertlich M, Canis M, Ihler F. Significance of endolymphatic sac surgery with and/or without simultaneous cochlea implant surgery in respect of vertigo control and speech perception in patients with Menière's disease. Eur Arch Otorhinolaryngol 2024; 281:639-647. [PMID: 37470816 PMCID: PMC10796641 DOI: 10.1007/s00405-023-08122-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2023] [Accepted: 07/10/2023] [Indexed: 07/21/2023]
Abstract
PURPOSE The focus on treating patients with Menière's Disease (MD) lies on the reduction of vertigo attacks and the preservation of sensory function. Endolympathic hydrops is considered as an epiphenomenon in MD, which can potentially be altered by endolymphatic sac surgery (ESS). Purpose of the study was to investigate the influences on vertigo control through manipulation of the perilymphatic system with or without ESS. METHODS Retrospective data analysis of 86 consecutive patients with MD according to current diagnostic criteria after endolymphatic sac surgery alone (ESSalone; n = 45), cochlear implantation (CI) alone (CIalone; n = 12), and ESS with CI (ESS + CI; n = 29), treated at a tertiary referral center. MAIN OUTCOME MEASURES vertigo control, speech perception pre- and postoperatively. RESULTS Gender, side, and preoperative treatment were similar in all groups. Age was younger in the ESSalone-group with 56.2 ± 13.0 years (CIalone = 64.2 ± 11.4 years; ESS + CI = 63.1 ± 9.7 years). Definitive MD was present in all the CIalone, in 79.3% of the ESS + CI and in 59.6% of the ESSalone-patients. Likewise, vertigo control rate was 100% in the CIalone, 89.7% in the ESS + CI and 66.0% in the ESSalone-group. CONCLUSIONS Vertigo control was improved in all three groups, however, superior in groups treated with CI, potentially contributed by the manipulation of both the endo- and perilymphatic systems. A more systematic characterization of the patients with larger case numbers and documentation of follow up data would be needed to evaluate a clinical effect more properly.
Collapse
|
70
|
Rajati M, Afzalzadeh MR, Daneshi A, Ajalloueyan M, Hashemi SB, Nourizadeh N, Ghasemi MM, Moradi A, Farhadi M, Asghari A, Mohebbi S. Cochlear Implantation in Children with Meningitis: A Multicenter Study on Auditory Performance and Speech Production Outcomes. Indian J Otolaryngol Head Neck Surg 2024; 76:508-513. [PMID: 38440496 PMCID: PMC10909004 DOI: 10.1007/s12070-023-04197-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2023] [Accepted: 08/28/2023] [Indexed: 03/06/2024] Open
Abstract
BACKGROUND This study aims to evaluate speech production outcomes and auditory performance in children with post-meningitis deafness who were treated with cochlear implants. Additionally, the study assesses the impact of electrode insertion depth on surgical outcomes.". METHODS We conducted a study on 66 pediatric patients with bilateral postmeningitis hearing loss who were being prepared for cochlear implantation at four tertiary referral academic institutions. The speech intelligibility rating (SIR) and categories of auditory performance (CAP) were evaluated after the first and second years following implantation. The patients were divided into two groups based on electrode insertion depth: one group had full electrode insertion (more than two-thirds), while the other had partial electrode insertion (less than two-thirds). We compared the SIR and CAP scores between the two groups to assess the impact of electrode insertion depth on outcomes. RESULTS Before implantation, the median CAP score was one, but it improved significantly to six within two years after the procedure (P-value < 0.001). Similarly, the median SIR score before implantation was one, but it improved significantly to three within two years after surgery (P-value < 0.001). However, there was no significant difference between the partial and full electrode insertion groups in terms of CAP and SIR scores during the follow-up evaluations conducted after the first and second years. CONCLUSION The study found that cochlear implantation significantly improved speech production skills and auditory performance in children with postmeningitis deafness. Importantly, the amount of electrode insertion at the time of implantation did not have a significant impact on the outcomes.
Collapse
|
71
|
Morales-Puebla JM, Gavilán J, Lassaletta L. Inverted clip technique for cochlear implant electrode array fixation: how I do it. Eur Arch Otorhinolaryngol 2024; 281:1057-1060. [PMID: 38001386 DOI: 10.1007/s00405-023-08329-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2023] [Accepted: 10/31/2023] [Indexed: 11/26/2023]
Abstract
BACKGROUND Electrode migration has been identified as a complication primarily related to straight electrodes. To address this issue, the use of a fixation clip has been suggested as an alternative to stabilize the electrode lead and reduce the risk of migration. METHODS A modified approach to the standard fixation clip procedure is introduced. Steps and technical considerations are presented in the video attached. CONCLUSIONS This novel configuration offers enhanced fixation of the electrode array without requiring additional surgical time and without posing any additional risk to the facial nerve.
Collapse
|
72
|
Joshi C, Shah R, Sheth V, Pandit V. Non-Users and Limited Users of Cochlear Implants in Pediatric Patients: A Retrospective Cross-Sectional Study. Indian J Otolaryngol Head Neck Surg 2024; 76:910-914. [PMID: 38440544 PMCID: PMC10908936 DOI: 10.1007/s12070-023-04318-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2023] [Accepted: 10/21/2023] [Indexed: 03/06/2024] Open
Abstract
To determine the prevalence of non-use and limited use of cochlear implants. To find out the reasons for the same. This study was carried out among the paediatric patients who underwent cochlear implantation under the SHP* scheme in Civil Hospital, Ahmedabad between 2013 and 2020. STUDY DESIGN Retrospective cross-sectional study. STUDY SETTING Civil Hospital Ahmedabad. SAMPLE SIZE 150 paediatric patients. Patients were selected based on a random number generator. The data was collected through a telephonic interview based upon a preformed questionnaire. The study indicates that out of a total 150 participants, 109 (72.7%) used their cochlear implant regularly while 41 (27.3%) did not. Major issue faced by the participants was in the external device -damage to the device and monetary issues for its repair. The participants who have dropped the usage of their implants faced issues mostly after 2 years of usage. The age group of less than 3 years showed 15.6% of non-usage, while the age group of 3-6 years showed an increase to 34.5% of non-users. The age group of more than 6 years showed an even higher proportion (41.3%) of non-users. It is recommended that the government ensures the follow-up of the patients undergoing cochlear implantation for at least 2 years after the surgery. The proportion of non-users in the consecutive increasing age groups saw a rise in number. Therefore, it is recommended to divert the resources towards lower age groups to facilitate a better outcome.
Collapse
|
73
|
Tercyak S, Evans Z, Nahas G, Behzadpour H, Preciado D, Reilly B. Pediatric cochlear implantation: Early surgical intervention and parental quality of life. Int J Pediatr Otorhinolaryngol 2024; 177:111867. [PMID: 38290273 DOI: 10.1016/j.ijporl.2024.111867] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/06/2023] [Revised: 12/18/2023] [Accepted: 01/10/2024] [Indexed: 02/01/2024]
Abstract
OBJECTIVES Pediatric cochlear implantation (CI) provides sound perception to children with significant sensorineural hearing loss and, despite its challenging process, early implantation can enhance children's speech/language outcomes and potentially improve parental quality of life (PQoL). This study aims to examine parental perspectives on quality of life and parenting children with CI. METHODS This study combined retrospective chart review and parent reported outcomes. Data were abstracted from medical charts of 85 children who underwent CI between 2016 and 2022 at a tertiary pediatric hospital. Parents were administered the Acceptance and Action Questionnaire (AAQ-MCHL), an 8-item self-report assessment of quality of life for parents of children with CI. Multivariate linear regression analyses examined clinical factors associated with PQoL scores. RESULTS Parents whose children were implanted at less than two years of age reported significantly higher PQoL, indicated by lower AAQ scores, with a mean AAQ-MCHL of 7.6 + 5.7. In contrast, implantation at age >2 years yielded a mean AAQ-MCHL of 16.2 + 9.6. Parents interviewed within one year post-surgery reported lower PQoL, with a mean AAQ-MCHL of 12.3 + 8.8 compared to those interviewed after one year, with 20.5 + 10.4. CONCLUSION Early identification of profound hearing loss in children, coupled with early surgical CI, may be associated with higher parental quality of life. The beneficial outcomes appear to be potentiated over time. Further research is essential to fully comprehend the impact of CI on the quality of life of children and their parents.
Collapse
|
74
|
Sahara T, Kashio A, Kamogashira T, Ogata E, Akamatsu Y, Yamasoba T. Cochlear implantation for progressive hearing loss caused by an A8296G mutation in mitochondrial DNA. Auris Nasus Larynx 2024; 51:82-85. [PMID: 37573175 DOI: 10.1016/j.anl.2023.07.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2022] [Revised: 07/21/2023] [Accepted: 07/26/2023] [Indexed: 08/14/2023]
Abstract
Mitochondrial DNA mutations such as A3243G or A1555G are widely reported to cause hearing loss, but few reports exist on the A8296G mutation, which can also cause hearing loss. This report presents the case of a patient with the A8296G mutation and severe bilateral sensorineural hearing loss (SNHL) that progressed over two decades. The patient had no history of diabetes, but did have a family history of SNHL in her father and maternal grandmother. She was first diagnosed with SNHL at 45 years of age, and an A8296G mutation was found. The hearing threshold in the low-frequency range of the right ear was preserved at diagnosis, but eventually declined resulting in severe bilateral hearing loss by the age of 66 years, and cochlear implantation (CI) was performed in the left ear. The hearing threshold three months after CI was 25-45 dB HL, and the phoneme speech discrimination score in the left ear improved from 20% without CI to 74% with CI. SNHL patients with the A8295G mutation are good candidates for treatment with CI.
Collapse
|
75
|
Calvino M, Zuazua A, Sanchez-Cuadrado I, Gavilán J, Mancheño M, Arroyo H, Lassaletta L. Meludia platform as a tool to evaluate music perception in pediatric and adult cochlear implant users. Eur Arch Otorhinolaryngol 2024; 281:629-638. [PMID: 37480418 PMCID: PMC10796694 DOI: 10.1007/s00405-023-08121-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2023] [Accepted: 07/10/2023] [Indexed: 07/24/2023]
Abstract
PURPOSE Music perception is one of the greatest challenges for cochlear implant (CI) users. The aims of this study were: (i) to evaluate the music perception of CI users using the online Meludia music training program as music testing platform, (ii) to compare performance among three age groups, and (iii) to compare CI users with their normal hearing (NH) peers. METHODS 138 individuals participated, divided between children (6-10 y), adolescents (11-16 y), and adults (≥ 17 y). Five music perception tasks were evaluated: Rhythm, Spatialization, Stable/unstable, Melody, and Density. We also administered the music related quality of life (MuRQoL) questionnaire for adults, and a music questionnaire for pediatric population (6-16 y) (MuQPP). RESULTS A significantly higher percentage of the adolescent CI users completed the five tasks compared to the other age groups. Both pediatric and adolescent CI users had similar performance to their NH peers in most categories. On the MuRQoL, adult NH listeners reported more music exposure than CI users (3.8 ± 0.6 vs 3.0 ± 0.6, p < 0.01), but both groups reported similar levels of perceived music importance (3.4 ± 0.7 vs 3.2 ± 1.1, p = 0.340). On the MuQPP, pediatric CI users who scored highly on music perception also had higher reported questionnaire scores (54.2 ± 12.9 vs 40.9 ± 12.1, p = 0.009). CONCLUSIONS Meludia can be used to evaluate music perception and to use for music training in CI users of all ages. Adolescents had the highest performance in most musical tasks. Pediatric CI users were more similar to their NH peers. The importance of music in adult CI users was comparable to their NH peers.
Collapse
|