51
|
Liu X, Wang F, Meng Y, Zhao L, Shi W, Wang X, He Z, Chao J, Li C. Electrochemical/visual microfluidic detection with a covalent organic framework supported platinum nanozyme-based device for early diagnosis of pheochromocytoma. Biosens Bioelectron 2022; 207:114208. [PMID: 35344731 DOI: 10.1016/j.bios.2022.114208] [Citation(s) in RCA: 16] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2022] [Revised: 03/18/2022] [Accepted: 03/19/2022] [Indexed: 02/08/2023]
Abstract
The development of smart, portable, and sensitive devices for the monitoring of circulating tumor cells (CTCs) is essential to diagnose several diseases, including pheochromocytoma (PCC). Therefore, in this study, a dual-mode (electrochemical/visual) microfluidic device was designed for the rapid and sensitive detection of PCC-CTCs using a microfluidic chip for automatic cell sampling and detection and a smartphone-based three-dimensional-printed accessory for signal output analysis. The device was employed to capture and identify PCC-CTCs via specific immunogenic binding to the norepinephrine transporter and somatostatin receptor, which are overexpressed on the surface of PCC cells. Specifically, targeted-modified magnetic particles were used to capture and separate PCC-CTCs from peripheral blood; then, similarly modified covalent organic framework based nanozymes (COF@Pt) were used as peroxidase mimics to amplify the electrochemical response from H2O2 reduction and catalyze the oxidation of 3,3',5,5'-tetramethylbenzidine by hydroxyl radicals in the presence of the PCC cells to enable visual quantification. Using the prepared microfluidic device, a low detection limit of 1 cell mL-1 at a signal-to-noise ratio of 3 and a wide linear range of 2 to 105 cells mL-1 were achieved. Overall, this work demonstrates a portable, sensitive, and visual platform for PCC diagnostics that meets the requirement for quick and precise point-of-care diagnostics.
Collapse
|
52
|
Ho TM, Razzaghi A, Ramachandran A, Mikkonen KS. Emulsion characterization via microfluidic devices: A review on interfacial tension and stability to coalescence. Adv Colloid Interface Sci 2022; 299:102541. [PMID: 34920366 DOI: 10.1016/j.cis.2021.102541] [Citation(s) in RCA: 42] [Impact Index Per Article: 21.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2021] [Revised: 09/22/2021] [Accepted: 10/03/2021] [Indexed: 01/29/2023]
Abstract
Emulsions have gained significant importance in many industries including foods, pharmaceuticals, cosmetics, health care formulations, paints, polymer blends and oils. During emulsion generation, collisions can occur between newly-generated droplets, which may lead to coalescence between the droplets. The extent of coalescence is driven by the properties of the dispersed and continuous phases (e.g. density, viscosity, ion strength and pH), and system conditions (e.g. temperature, pressure or any external applied forces). In addition, the diffusion and adsorption behaviors of emulsifiers which govern the dynamic interfacial tension of the forming droplets, the surface potential, and the duration and frequency of the droplet collisions, contribute to the overall rate of coalescence. An understanding of these complex behaviors, particularly those of interfacial tension and droplet coalescence during emulsion generation, is critical for the design of an emulsion with desirable properties, and for the optimization of the processing conditions. However, in many cases, the time scales over which these phenomena occur are extremely short, typically a fraction of a second, which makes their accurate determination by conventional analytical methods extremely challenging. In the past few years, with advances in microfluidic technology, many attempts have demonstrated that microfluidic systems, characterized by micrometer-size channels, can be successfully employed to precisely characterize these properties of emulsions. In this review, current applications of microfluidic devices to determine the equilibrium and dynamic interfacial tension during droplet formation, and to investigate the coalescence stability of dispersed droplets applicable to the processing and storage of emulsions, are discussed.
Collapse
|
53
|
Garone MG, D'Antoni C, Rosa A. Culture of Human iPSC-Derived Motoneurons in Compartmentalized Microfluidic Devices and Quantitative Assays for Studying Axonal Phenotypes. Methods Mol Biol 2022; 2429:189-199. [PMID: 35507162 DOI: 10.1007/978-1-0716-1979-7_12] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
In order to use induced Pluripotent Stem Cells (iPSCs) to model neurodegenerative diseases, efficient and homogeneous generation of neurons in vitro represents a key step. Here we describe a method to obtain and characterize functional human spinal and cranial motoneurons using a combined approach of microfluidic chips and programs designed for scientific multidimensional imaging. We have used this approach to analyze axonal phenotypes. These tools are useful to investigate the cellular and molecular bases of neuromuscular diseases, including amyotrophic lateral sclerosis and spinal muscular atrophy.
Collapse
|
54
|
Wang T, Meunier FA. Live-Cell Superresolution Imaging of Retrograde Axonal Trafficking Using Pulse-Chase Labeling in Cultured Hippocampal Neurons. Methods Mol Biol 2022; 2473:101-128. [PMID: 35819762 DOI: 10.1007/978-1-0716-2209-4_9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
The entanglement of long axons found in cultured dissociated hippocampal neurons restricts the analysis of the machinery underlying directed axonal trafficking. Further, hippocampal neurons exhibit "en passant" presynapses that may confound the analysis of long-range retrograde axonal transport. To solve these issues, we and others have developed microfluid-based methods to specifically follow the fates of the retrograde axonal cargoes following pulse-chase labeling by super-resolution live-cell imaging, and automatically tracking their directed transport and analyzing their kinetical properties. These methods have allowed us to visualize the trafficking of fluorescently tagged signaling endosomes and autophagosomes derived from axonal terminals and resolve their localizations and movements with high spatial and temporal accuracy. In this chapter, we describe how to use a commercially available microfluidic device to enable the labeling and tracking of retrograde axonal carriers, including (1) how to culture and transfect rat hippocampal neurons in the microfluidic device; (2) how to perform pulse-chase to label specific populations of retrograde axonal carriers; and (3) how to conduct the automatic tracking and data analysis using open-source software.
Collapse
|
55
|
Aboulkheyr Es H, Aref AR, Warkiani ME. Generation and Culture of Organotypic Breast Carcinoma Spheroids for the Study of Drug Response in a 3D Microfluidic Device. Methods Mol Biol 2022; 2535:49-57. [PMID: 35867221 DOI: 10.1007/978-1-0716-2513-2_4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Breast cancer (BC) is a leading cause of cancer death among women worldwide. To better understand and predict therapeutic response in BC patient developing a fast, low-cost, and reliable preclinical tumor from patient's tumor specimen is needed. Here, we describe the development of a preclinical model of BC through the generation and ex vivo culture of patient-derived organotypic tumor spheroids (PDOTS) in a 3D microfluidic device. Moreover, the real-time screening of conventional chemotherapy agents on cultured PDOTS is also described.
Collapse
|
56
|
Chow SYA, Nakanishi Y, Kaneda S, Ikeuchi Y. Modeling Axonal Degeneration Using Motor Nerve Organoids. Methods Mol Biol 2022; 2515:89-97. [PMID: 35776347 DOI: 10.1007/978-1-0716-2409-8_6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Degeneration of axons is characteristic of many devastating diseases including amyotrophic lateral sclerosis (ALS). However, lack of an in vitro neuronal culture system that mimics damages on nerves and axonal tracts hampered development of effective treatments. Here, we describe a method to model degeneration of motor neuron axons using motor nerve organoids that are formed with human induced pluripotent stem cells. In this protocol, motor neuron axon degeneration can be rapidly induced with chemical damages. Neuroprotective effects of compounds can be examined using the degenerated axons. This motor neuron axon bundle degeneration model should facilitate future screening for drugs against diseases affecting axon fascicles.
Collapse
|
57
|
Abstract
Extracellular vesicles (EVs) are lipid-bilayer-enclosed vesicles with sub-micrometer size that are released by various cells. EVs contain a tissue-specific signature wherein a variety of proteins and nucleic acids are selectively packaged. Growing evidence has shown important biological roles and clinical relevance of EVs in diseases. For EV-related studies to thrive, rapid efficient isolation of pure EVs is a prerequisite. However, lengthy procedure, low yield, low throughput, and high contaminants stemmed from existing isolation approaches hamper both basic research and large-scale clinical implementation. We have shown that lipid nanoprobes (LNP) enable spontaneous labeling and rapid isolation of EVs by coupling with magnetic enrichment. Recently, we further developed a one-step EV isolation platform that utilizes EV size-matched silica nanostructures and surface-conjugated LNPs with an integrated microfluidic mixer. EVs, derived from up to 2-ml clinical plasma, can be processed with this point-of-care device using optimized flow rate. Subsequently, contents of isolated EVs can be extracted on-chip and eluted from the device for downstream molecular analyses. The LNP-functionalized microfluidic device combined with state-of-the-art analysis platforms could have great potential in promoting EV-centered research and clinical use in the future.
Collapse
|
58
|
Dowlatshah S, Saraji M, Pedersen-Bjergaard S, Ramos-Payán M. Microfluidic liquid-phase microextraction based on natural deep eutectic solvents immobilized in agarose membranes. J Chromatogr A 2021; 1657:462580. [PMID: 34624712 DOI: 10.1016/j.chroma.2021.462580] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2021] [Revised: 09/17/2021] [Accepted: 09/20/2021] [Indexed: 01/25/2023]
Abstract
In liquid-phase microextraction (LPME), the sample and the acceptor are separated by a synthetic organic solvent, which is immobilized in a porous polymeric membrane of polypropylene or polyvinylidene fluoride. The organic solvent serves as extraction phase, while the polymeric membrane serves as support membrane. The combination of extraction phase and support membrane is termed supported liquid membrane (SLM). In this paper, we developed for the first time fully green and biodegradable supported SLMs, based on natural deep eutectic solvents as extraction phase and agarose as support membrane. This highly green approach was developed and studied with sulfonamide pharmaceuticals as model analytes, and performance was compared with LPME using conventional SLMs. All experiments were conducted in a microfluidic device. Model analytes were extracted from acidic sample (pH1.0) and into alkaline acceptor (pH12.0). Both sample and acceptor were pumped at 1 μL min-1 into the microfluidic device, and the optimal SLM was based on 3 µL of coumarin and thymol (1:2 molar ratio) as the extraction phase. The proposed green microfluidic device was successfully applied for the determination of sulfonamides in urine samples with spiking recoveries in the range of 77-100%. LPME with deep eutectic solvent immobilized in agarose showed similar performance as with conventional SLMs. Thus, the data presented in this paper demonstrate that highly green microextraction systems may be developed in the future, based on natural solvents and biodegradable materials.
Collapse
|
59
|
Utoh R, Enomoto S, Yamada M, Yamanaka K, Yajima Y, Furusawa K, Seki M. Polyanion-induced, microfluidic engineering of fragmented collagen microfibers for reconstituting extracellular environments of 3D hepatocyte culture. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2021; 129:112417. [PMID: 34579926 DOI: 10.1016/j.msec.2021.112417] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/27/2021] [Revised: 08/23/2021] [Accepted: 08/30/2021] [Indexed: 12/11/2022]
Abstract
Artificial biological scaffolds made of extracellular matrix (ECM) components, such as type I collagen, provide ideal physicochemical cues to various cell culture platforms. However, it remains a challenge to fabricate micrometer-sized ECM materials with precisely controlled morphologies that could reconstitute the 3-dimensional (3D) microenvironments surrounding cells. In the present study, we proposed a unique process to fabricate fragmented collagen microfibers using a microfluidic laminar-flow system. The continuous flow of an acidic collagen solution was neutralized to generate solid fibers, which were subsequently fragmented by applying a gentle shear stress in a polyanion-containing phosphate buffer. The morphology of the fiber fragment was controllable in a wide range by changing the type and/or concentration of the polyanion and by tuning the applied shear stress. The biological benefits of the fragmented fibers were investigated through the formation of multicellular spheroids composed of primary rat hepatocytes and microfibers on non-cell-adhesive micro-vessels. The microfibers enhanced the survival and functions of the hepatocytes and reproduced proper cell polarity, because the fibers facilitated the formation of cell-cell and cell-matrix interactions while modulating the close packing of cells. These results clearly indicated that the microengineered fragmented collagen fibers have great potential to reconstitute extracellular microenvironments for hepatocytes in 3D culture, which will be of significant benefit for cell-based drug testing and bottom-up tissue engineering.
Collapse
|
60
|
Baranger C, Pezron I, Lins L, Deleu M, Le Goff A, Fayeulle A. A compartmentalized microsystem helps understanding the uptake of benzo[a]pyrene by fungi during soil bioremediation processes. THE SCIENCE OF THE TOTAL ENVIRONMENT 2021; 784:147151. [PMID: 33895515 DOI: 10.1016/j.scitotenv.2021.147151] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/22/2021] [Revised: 04/01/2021] [Accepted: 04/11/2021] [Indexed: 06/12/2023]
Abstract
Hydrophobic organic soil contaminants such as polycyclic aromatic hydrocarbons (PAH) are poorly mobile in the aqueous phase and tend to sorb to the soil matrix, resulting in low bioavailability. Some filamentous fungi are efficient in degrading this kind of pollutants. However, the mechanism of mobilization of hydrophobic compounds by non-motile microorganisms such as filamentous fungi needs investigations to improve pollutant bioavailability and bioremediation efficiency. Usual homogeneous media for microbial growth in the lab are poorly suited to model the soil, which is a compartmentalized and heterogeneous habitat. A microfluidic device was designed to implement a compartmentalization of the fungal inoculum and the source of the pollutant benzo[a]pyrene (BaP) as a deposit of solid crystals in order to gain a further insight into the mechanisms involved in the access to the contaminant and its uptake in soils. Thus in this device, two chambers are connected by an array of parallel microchannels that are wide enough to allow individual hyphae to grow through them. Macro-cultures of Talaromyces helicus in direct contact with BaP have shown its uptake and intracellular storage in lipid bodies despite the low propensity of BaP to cross aqueous phases as shown by simulation. Observations of T. helicus in the microfluidic device through laser scanning confocal microscopy indicate preferential uptake of BaP at a close range and through contact with the cell wall. However faint staining of some hyphae before contact with the deposit also suggests an extracellular transport phenomenon. Macro-culture filtrates analyses have shown that T. helicus releases extracellular non-lipidic surface-active compounds able to lower the surface tension of culture filtrates to 49.4 mN/m. Thus, these results highlight the significance of active mechanisms to reach hydrophobic contaminants before their uptake by filamentous fungi in compartmentalized micro-environments and the potential to improve them through biostimulation approaches for soil mycoremediation.
Collapse
|
61
|
Otomo A, Ono S, Sato K, Mitsui S, Shimakura K, Kimura H, Hadano S. High-throughput quantitative analysis of axonal transport in cultured neurons from SOD1 H46R ALS mice by using a microfluidic device. Neurosci Res 2021; 174:46-52. [PMID: 34352295 DOI: 10.1016/j.neures.2021.07.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2021] [Revised: 07/15/2021] [Accepted: 07/30/2021] [Indexed: 11/15/2022]
Abstract
Amyotrophic lateral sclerosis (ALS) is a neurodegenerative disease characterized by selective loss of motor neurons. We have previously shown that autophagosome-like vesicular structures are progressively accumulated in the spinal axons of an ALS mouse model, overexpressing human Cu/Zn superoxide dismutase (SOD1) mutant, prior to the onset of motor symptoms. This suggests that axonal transport perturbation can be an early sign of neuronal dysfunction. However, the exact causal relationship between axonal transport deficits and neurodegeneration is not fully understood. To clarify whether axonal transport of organelles even in neurons at early developmental stages was affected by overexpression of mutant SOD1, we conducted a microfluidic device-based high-throughput quantitative analysis of the axonal transport of acidic vesicles and mitochondria in primary cultured cortical neurons established from SOD1H46R transgenic mice. Compared to wild-type (WT), a significantly increased number of motile acidic vesicles, i.e., autophagosomes and/or late-endosomes, was observed in the axons of SOD1H46R neurons. By contrast, mitochondria moving along the axons were significantly decreased in SOD1H46R compared to WT. Since such phenotypes, where the axonal transport of these organelles is differently affected by mutant SOD1 expression, emerge before axonal degeneration, axonal transport deficits could dysregulate axon homeostasis, thereby ultimately accelerating neurodegeneration.
Collapse
|
62
|
Rahman MRU, Kwak TJ, Woehl JC, Chang WJ. Effect of geometry on dielectrophoretic trap stiffness in microparticle trapping. Biomed Microdevices 2021; 23:33. [PMID: 34185161 DOI: 10.1007/s10544-021-00570-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/11/2021] [Indexed: 10/21/2022]
Abstract
Dielectrophoresis, an electrokinetic technique, can be used for contactless manipulation of micro- and nano-size particles suspended in a fluid. We present a 3-D microfluidic DEP device with an orthogonal electrode configuration that uses negative dielectrophoresis to trap spherical polystyrene micro-particles. Traps with three different basic geometric shapes, i.e. triangular, square, and circular, and a fixed trap area of around 900 μm2 were investigated to determine the effect of trap shape on dynamics and strength of particle trapping. Effects of trap geometry were quantitatively investigated by means of trap stiffness, with applied electric potentials from 6 VP-P to 10 VP-P at 1 MHz. Analyzing the trap stiffness with a trapped 4.42 μm spherical particle showed that the triangular trap is the strongest, while the square shape trap is the weakest. The trap stiffness grew more than eight times in triangular traps and six times in both square and circular traps when the potential of the applied electric field was increased from 6 VP-P to 10 VP-P at 1 MHz. With the maximum applied potential, i.e. 10 VP-P at 1 MHz, the stiffness of the triangular trap was 60% and 26% stronger than the square and circular trap, respectively. A finite element model of the microfluidic DEP device was developed to numerically compute the DEP force for these trap shapes. The findings from the numerical computation demonstrate good agreement with the experimental analysis. The analysis of three different trap shapes provides important insights to predict trapping location, strength of the trapping zone, and optimized geometry for high throughput particle trapping.
Collapse
|
63
|
Dowlatshah S, Santigosa E, Saraji M, Payán MR. A selective and efficient microfluidic method-based liquid phase microextraction for the determination of sulfonamides in urine samples. J Chromatogr A 2021; 1652:462344. [PMID: 34186325 DOI: 10.1016/j.chroma.2021.462344] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2021] [Revised: 06/07/2021] [Accepted: 06/08/2021] [Indexed: 11/30/2022]
Abstract
Liquid phase microextraction (LPME) into a microfluidic has undergone great advances focused on downscaled and miniaturized devices. In this work, a microfluidic device was developed for the extraction of sulfonamides in order to accelerate the mass transfer and passive diffusion of the analytes from the donor phase to the acceptor phase. The subsequent analysis was carried out by high performance liquid chromatography with UV-DAD (HPLC-DAD). Several parameters affecting the extraction efficiency of the method such as the supported liquid membrane, composition of donor and acceptor phase and flow rate were investigated and optimized. Tributyl phosphate was found to be a good supported liquid membrane which confers not only great affinity for analytes but also long-term stability, allowing more than 20 consecutive extractions without carry over effect. Under optimum conditions, extraction efficiencies were over 96 % for all sulfonamides after 10 minutes extraction and only 10 µL of sample was required. Relative standard deviation was between 3-5 % for all compounds. Method detection limits were 45, 57, 54 and 33 ng mL-1 for sulfadiazine (SDI), sulfamerazine (SMR), sulfamethazine (SMT) and sulfamethoxazole (SMX), respectively. Quantitation limits were 0.15, 0.19, 0.18 and 0.11 µg mL-1 for SDI, SMR, SMT SMX, respectively. The proposed microfluidic device was successfully applied for the determination of sulfonamides in urine samples with extraction efficiencies within the range of 86-106 %. The proposed method improves the procedures proposed to date for the determination of sulfonamides in terms of efficiency, reduction of the sample volume and extraction time.
Collapse
|
64
|
An efficient microfluidic device based on electromembrane extraction for the simultaneous extraction of acidic and basic drugs. Anal Chim Acta 2021; 1160:338448. [PMID: 33894962 DOI: 10.1016/j.aca.2021.338448] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2021] [Revised: 03/16/2021] [Accepted: 03/22/2021] [Indexed: 01/20/2023]
Abstract
The simultaneous extraction of acidic and basic compounds is considered a great challenge. In this work, an efficient and fast microfluidic device is described for the simultaneous determination of acidic and basic drugs by two electromembrane extraction, offering extraction efficiencies over 98% for all analytes in human urine samples and solving the difficulties encountered to date. The sample is submitted into the device and the collected acceptor phase is directly analyzed by diode array detector and high-pressure liquid chromatography (HPLC). The device consisted of three poly(methylmethacrylate) layers and four electrodes to perform EME in two steps in a single device. Two acidic analytes (ketoprofen and naproxen) and two basic analytes (amitriptyline and loperamide) were selected as model analytes. The device proposed works under stable electric field conditions, low current intensities that confers great stability to the supported liquid membrane. After a comprehensive study of the SLM, 1:1 2-nitrophenyl octhyl ether:dodecanol was selected as optimal. This device has also been successfully applied in 1:2 diluted bovine plasma samples with recoveries over 84% and a relative standard deviation below 6%. This microfluidic device needs small sample volumes (lower than 50 μL) and offers short extraction times (10 min) and excellent clean-up. Furthermore, it has proven to be a robust and reproducible device after more than 30 consecutive extractions, and thanks to the low potential required (5 V), it allows its compatibility with a single battery.
Collapse
|
65
|
Maximiano EM, Gonçalves DA, Martins CA, Angnes L, Gomes RS, Trindade MAG. Simultaneous separation and electroanalysis in a single polydimethylsiloxane-based platform. Talanta 2021; 233:122514. [PMID: 34215129 DOI: 10.1016/j.talanta.2021.122514] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2021] [Revised: 05/04/2021] [Accepted: 05/08/2021] [Indexed: 11/15/2022]
Abstract
Channel-based microfluidic devices integrating the separation step and detection system are key factors to expand microanalysis application. However, these devices still depend on macroscale external equipment for pre-treatment of the sample, separation, or detection. The integration of all steps in only one stage is critical to improving feasibility. Herein, we use a low-cost protocol to solve part of the challenge by designing a dual-mode system onto single polydimethylsiloxane (PDMS)-based platform - overall dimensions of 65 mm length × 20 mm width × 14 mm height and the inner diameter of 297±10 μm height × 605±19 μm width - for column-free separation and simultaneous detection. As a proof-of-concept, we used this all-in-one PDMS platform to separate - without the packet-based phase - and determine salicylic acid (SA) and caffeine (CAF) with a detection limit of 0.20 and 0.18 μmol L-1 and quantification limit of 0.70 and 0.60 μmol L-1 for SA and CAF, respectively. We separated the mixture using forced convection into a chemically treated microchannel while detecting the analytes in amperometric mode. Here, we report new insights into how integrating analytes separation and further electroanalysis into a single miniaturized device.
Collapse
|
66
|
A microfluidic column of water index-matched packed microspheres for label-free observation of water pollutants. Mikrochim Acta 2021; 188:143. [PMID: 33774708 DOI: 10.1007/s00604-021-04804-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2020] [Accepted: 03/20/2021] [Indexed: 10/21/2022]
Abstract
A microfluidic, label-free optical sensor for water pollutants, which is based on a packed micro-column of microspheres with refractive index similar to that of water, is presented. The perfluoropolyether microspheres are synthetized by membrane emulsification followed by UV irradiation. The microfluidic channel hosting the packed column is transparent when filled with pure water as a consequence of refractive index matching, whereas it scatters light in presence of compounds with lipophilic moieties that spontaneously adsorb on the fluorinated microspheres. The device is characterized by investigating the response to cationic and anionic surfactants. Both the signal growth rate and the recovery rate measured during washing with water depend on the type and concentration of the compounds. The cationic surfactants tested display a larger signal increase, linearly scaling with concentration. A limit of detection of 1 μM is obtained in the current configuration. The water index-matched microspheres enable to access an additional analytical parameter, that is the propagation velocity of the scattering signal along the column. This parameter is also found to scale linearly with concentration, hence providing a complementary analytical tool sensitive to the adhesion kinetics.
Collapse
|
67
|
Ohtsuka D, Ota N, Amaya S, Matsuoka S, Tanaka Y, Ueda M. A sub-population of Dictyostelium discoideum cells shows extremely high sensitivity to cAMP for directional migration. Biochem Biophys Res Commun 2021; 554:131-137. [PMID: 33784508 DOI: 10.1016/j.bbrc.2021.03.095] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2021] [Accepted: 03/17/2021] [Indexed: 01/26/2023]
Abstract
The chemotaxis of Dictysotelium discoideum cells in response to a chemical gradient of cyclic adenosine 3',5'-monophosphate (cAMP) was studied using a newly designed microfluidic device. The device consists of 800 cell-sized channels in parallel, each 4 μm wide, 5 μm high, and 100 μm long, allowing us to prepare the same chemical gradient in all channels and observe the motility of 500-1000 individual cells simultaneously. The percentage of cells that exhibited directed migration was determined for various cAMP concentrations ranging from 0.1 pM to 10 μM. The results show that chemotaxis was highest at 100 nM cAMP, consistent with previous observations. At concentrations as low as 10 pM, about 16% of cells still exhibited chemotaxis, suggesting that the receptor occupancy of only 6 cAMP molecules/cell can induce chemotaxis in very sensitive cells. At 100 pM cAMP, chemotaxis was suppressed due to the self-production and secretion of intracellular cAMP induced by extracellular cAMP. Overall, systematic observations of a large number of individual cells under the same chemical gradients revealed the heterogeneity of chemotaxis responses in a genetically homogeneous cell population, especially the existence of a sub-population with extremely high sensitivity for chemotaxis.
Collapse
|
68
|
Pungjunun K, Yakoh A, Chaiyo S, Praphairaksit N, Siangproh W, Kalcher K, Chailapakul O. Laser engraved microapillary pump paper-based microfluidic device for colorimetric and electrochemical detection of salivary thiocyanate. Mikrochim Acta 2021; 188:140. [PMID: 33772376 DOI: 10.1007/s00604-021-04793-2] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2020] [Accepted: 03/18/2021] [Indexed: 11/26/2022]
Abstract
A microcapillary grooved paper-based analytical device capable of dual-mode sensing (colorimetric and electrochemical detection) was demonstrated for analysis of viscous samples (e.g., human saliva). Herein, a hollow capillary channel was constructed via laser engraved micropatterning functions as a micropump to facilitate viscous fluidic transport, which would otherwise impede analysis on paper devices. Using salivary thiocyanate as a model analyte, the proposed device was found to exhibit a promising sensing ability on paper devices without the need for sample pretreatment or bulky instrumentation, as normally required in conventional methods used for saliva analysis. An extensive linear dynamic range covering detection of salivary thiocyanate for both high and trace level regimes (5 orders of magnitude working range) was collectively achieved using the dual-sensing modes. Under optimal conditions, the limit of detection was 6 μmol L-1 with a RSD of less than 5%. An excellent stability for the μpumpPAD was also observed for over 30 days. Real sample analysis using the proposed device was found to be in line with the standard chromatographic method. Benefitting from simple fabrication and operation, portability, disposability, low sample volume (20 μL), and low cost (< 1 USD), the μpumpPAD is an exceptional alternative tool for the detection of various biomarkers in saliva specimens.
Collapse
|
69
|
Wada KI, Hosokawa K, Ito Y, Maeda M. A Microfluidic Device for Modulation of Organellar Heterogeneity in Live Single Cells. ANAL SCI 2021; 37:499-505. [PMID: 33281140 DOI: 10.2116/analsci.20scp11] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
The quantitatively controlled organellar transfer between living single cells provides a unique experimental platform to analyze the contribution of organellar heterogeneity on cellular phenotypes. We previously developed a microfluidic device which can perform quantitatively controlled mitochondrial transfer between live single cells by promoting strictured cytoplasmic connections between live single cells, but its application to other organelles is unclear. In this study, we investigated the quantitative properties of peroxisome transfer in our microfluidic device. When cells were fused through a 10 or 4 μm long microtunnel by a Sendai virus envelope-based method, a strictured cytoplasmic connection was achieved with a length corresponding to that of the microtunnel, and a subsequent recovery culture disconnected the fused cells. The peroxisome number being transferred through a 10 μm length of the microtunnel was smaller than that of 4 μm. These data suggest that our microfuidic device can perform a quantitative control of peroxisome transfer.
Collapse
|
70
|
Lei KF, Ho YC, Huang CH, Huang CH, Pai PC. Characterization of stem cell-like property in cancer cells based on single-cell impedance measurement in a microfluidic platform. Talanta 2021; 229:122259. [PMID: 33838770 DOI: 10.1016/j.talanta.2021.122259] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2020] [Revised: 02/01/2021] [Accepted: 02/24/2021] [Indexed: 11/20/2022]
Abstract
Investigation of stem cell-like property in cancer cells is important for the development of new therapeutic drugs targeting at malignant tumors. Currently, the standard approach for identifying cancer stem cell-like cells relies on the recognition of stem cell surface markers. However, the reliability remains controversial among biologists. In the current work, a dielectrophoretic and impedimetric hybrid microfluidic platform was developed for capturing single cells and characterizing their stem cell-like property. Single cells were captured in 20 μm trapping wells by dielectrophoretic force and their impedance spectra were measured by an impedance analyzer. The result showed that different cancer cell lines could be differentiated by impedance magnitude ranging between 2 and 20 kHz. Moreover, cancer cells and cancer stem cell-like cells could be categorized by a 2-dimensional graph of the impedance magnitudes at 2 and 20 kHz. The stem cell-like property in cancer cells was verified by stem cell surface markers and single-cell derived colony assay. Comparing with bio-chemical approach, i.e., surface markers, bio-physical approach, i.e., cell impedance, is a label-free technique to identify cancer stem cell-like cells.
Collapse
|
71
|
Ge A, Hu L, Fan J, Ge M, Wang X, Wang S, Feng X, Du W, Liu BF. A low-cost microfluidic platform coupled with light emitting diode for optogenetic analysis of neuronal response in C. elegans. Talanta 2021; 223:121646. [PMID: 33303134 DOI: 10.1016/j.talanta.2020.121646] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2020] [Revised: 09/02/2020] [Accepted: 09/06/2020] [Indexed: 11/24/2022]
Abstract
Optogenetic method is widely used for dissecting the neuronal function and connectivity in a specific neural circuit, which can help understanding how the animal process information and generate behavior. The nematode C. elegans has a simple but complete nervous system, making it an attractive model to study the dynamics signals of neural circuits. However, in vivo analysis on neural circuits usually rely on the complex and expensive optical equipment to allow optogenetic stimulating the neuron while recording its activities in such a freely moving animal. Hence, in this paper we reported a portable optofluidic platform that works based on optical fiber illumination and functional imaging for worm optogenetic manipulation. A light beam from LED laser pen crossing the 3D-printed optical fiber channel is used to activate the neurons specific-expressed with light sensitive proteins ChR-2. The imaging light path is perpendicular to the stimulation light, which allows activating neuron precisely and measuring cellular signals simultaneously. By using such an easy-to-assemble device, optical stimulation of the specific neurons and detection of dynamic calcium responses of other neurons could be proceeded simultaneously. Thus, the developed microfluidic platform puts forward a simple, rapid and low-cost strategy for further neural circuits studies.
Collapse
|
72
|
Rahman MRU, Kwak TJ, Woehl JC, Chang WJ. Quantitative analysis of the three-dimensional trap stiffness of a dielectrophoretic corral trap. Electrophoresis 2021; 42:644-655. [PMID: 33340119 DOI: 10.1002/elps.202000222] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2020] [Revised: 12/07/2020] [Accepted: 12/14/2020] [Indexed: 11/08/2022]
Abstract
Dielectrophoresis is a robust approach for the manipulation and separation of (bio)particles using microfluidic platforms. We developed a dielectrophoretic corral trap in a microfluidic device that utilizes negative dielectrophoresis to capture single spherical polystyrene particles. Circular-shaped micron-size traps were employed inside the device and the three-dimensional trap stiffness (restoring trapping force from equilibrium trapping location) was analyzed using 4.42 μm particles and 1 MHz of an alternating electric field from 6 VP-P to 10 VP-P . The trap stiffness increased exponentially in the x- and y-direction, and linearly in the z-direction. Image analysis of the trapped particle movements revealed that the trap stiffness is increased 608.4, 539.3, and 79.7% by increasing the voltage from 6 VP-P to 10 VP-P in the x-, y-, and z-direction, respectively. The trap stiffness calculated from a finite element simulation of the device confirmed the experimental results. This analysis provides important insights to predict the trapping location, strength of the trapping, and optimum geometry for single particle trapping and its applications such as single-molecule analysis and drug discovery.
Collapse
|
73
|
Single-use microfluidic device for purification and concentration of environmental DNA from river water. Talanta 2021; 226:122109. [PMID: 33676665 DOI: 10.1016/j.talanta.2021.122109] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2020] [Revised: 01/04/2021] [Accepted: 01/09/2021] [Indexed: 12/29/2022]
Abstract
Purification and concentration of DNA is a critical step on DNA-based analysis, which should ensure efficient DNA isolation and effective removal of contaminants that may interfere with downstream DNA amplification. Complexity of samples, minute content of target analyte, or high DNA fragmentation greatly entangles the success of this step. To overcome this issue, we designed and fabricated a novel miniaturized disposable device for a highly efficient DNA purification. The microfluidic device showed binding efficiency and elution yield of 90.1% and 86.7%, respectively. Moreover, the effect of DNA fragmentation, a parameter that has not been previously addressed, showed a great impact in the recovery step. The microfluidic system integrated micropillars with chitosan being used as the solid-phase for a pH-dependent DNA capture and release. We have showed the potential of the device in the successful purification of environmental DNA (eDNA) from river water samples contaminated with Dreissena polymorpha, an invasive alien species responsible for unquestionable economic and environmental consequences in river water basins. Additionally, the device was also able to concentrate the DNA extract from highly diluted samples, showing promising results for the early detection of such invasive species, which may allow prompt measures for a more efficient control in affected areas. Suitability for integration with downstream DNA analysis was also demonstrated through qPCR analysis of the samples purified with the microfluidic device, allowing detection of the target species even if highly diluted.
Collapse
|
74
|
Younis MA, Khalil IA, Elewa YHA, Kon Y, Harashima H. Ultra-small lipid nanoparticles encapsulating sorafenib and midkine-siRNA selectively-eradicate sorafenib-resistant hepatocellular carcinoma in vivo. J Control Release 2021; 331:335-349. [PMID: 33484779 DOI: 10.1016/j.jconrel.2021.01.021] [Citation(s) in RCA: 50] [Impact Index Per Article: 16.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2020] [Revised: 12/24/2020] [Accepted: 01/14/2021] [Indexed: 02/07/2023]
Abstract
Hepatocellular carcinoma (HCC) is a fatal disease with limited therapeutic choices. The stroma-rich tumor microenvironment hinders the in vivo delivery of most nanomedicines. Ultra-small lipid nanoparticles (usLNPs) were designed for the selective co-delivery of the cytotoxic drug, sorafenib (SOR), and siRNA against the Midkine gene (MK-siRNA) to HCC in mice. The usLNPs composed of a novel pH-sensitive lipid, a diversity of phospholipids and a highly-selective targeting peptide. A microfluidic device, iLiNP, was used and a variety of factors were controlled to tune particle size aiming at maximizing tumor penetration efficiency. Optimizing the composition and physico-chemical properties of the usLNPs resulted in an enhanced tumor accumulation, selectivity and in vivo gene silencing. The optimized usLNPs exerted potent gene silencing in the tumor (median effective dose, ED50~0.1 mg/Kg) with limited effect on the healthy liver. The novel combination synergistically-eradicated HCC in mice (~85%) at a surprisingly-low dose of SOR (2.5 mg/Kg) which could not be achieved via individual monotherapy. Toxicity studies revealed the biosafety of the usLNPs upon either acute or chronic treatment. Furthermore, the SOR-resistant HCC established in mice was eradicated by 70% using this approach. We conclude that our strategy is promising for potential clinical applications in HCC treatment.
Collapse
|
75
|
Developing an integrated microfluidic and miniaturized electrochemical biosensor for point of care determination of glucose in human plasma samples. Anal Bioanal Chem 2021; 413:1441-1452. [PMID: 33388843 DOI: 10.1007/s00216-020-03108-3] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2020] [Revised: 11/22/2020] [Accepted: 12/01/2020] [Indexed: 12/11/2022]
Abstract
A cost-effective, point of care (POC) device based on highly oriented CNT arrays was developed as an electrochemical assay for real-time and sensitive detection of glucose in complex samples. A low-cost, microcontroller-based potentiostat consisting of Arduino Due and LMP9100-EVM was developed to perform electrochemical measurements such as cyclic voltammetry (CV) and amperometry. A syringe pump based on open-source electronics was designed to direct the flow through a microfluidic chip. Vertically aligned carbon nanotube (VACNT) sensor arrays, in combination with the miniature potentiostat and the syringe pumps, were utilized as a POC device for the rapid and accurate detection of glucose. The structure and morphology of samples were characterized by field emission scanning electron microscopy (FESEM) and attenuated total reflectance Fourier transform infrared spectrometry (ATR-FTIR). CV as well as electrochemical impedance spectroscopy (EIS) was performed to investigate the electrochemical behavior of the electrode with respect to different diffusion regimes. The mediator-less biosensor had a limit of detection of 23 μM and sensitivity of 1462 μA mM-1 cm-2 and 1050 μA mM-1 cm-2 at the linear range of 1.2-7.8 mM and 7.8-11.2 mM, respectively. The presence of other biological compounds such as uric acid (UA) and ascorbic acid (AA) did not interfere with the detection of glucose. Finally, the designed POC device was successfully applied for the determination of glucose in human blood plasma samples.
Collapse
|