76
|
PUCHTLER H, ISLER H. THE EFFECT OF PHOSPHOMOLYBDIC ACID ON THE STAINABILITY OF CONNECTIVE TISSUES BY VARIOUS DYES. J Histochem Cytochem 2017; 6:265-70. [PMID: 13563844 DOI: 10.1177/6.4.265] [Citation(s) in RCA: 55] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
The mechanism of the selective staining of connective tissue obtained in trichrome methods (e.g. Masson, Heidenhain, Goldner) by "mordanting" with phosphomolybdic acid was investigated in sections of rat intestine. Information on the distribution of phosphomolybdic acid was obtained by treating sections with this acid and then with stannous chloride. The molybdenum blue thus obtained was located in those very structures which were stained selectively in trichrome methods. The chemical characteristics of the dyes taken up after phosphomolybdic acid treatment were investigated by comparing sections stained with acid, basic and amphoteric dyes. In the absence of phosphomolybdic acid, only dyes with acidic groups yielded a staining of connective tissue, but this staining was not selective. In sections pretreated with phosphomolybdic acid, only dyes with basic groups stained connective tissue, and only dyes with strong basic groups yielded a selective staining of these structures. Basic and amphoteric dyes applied after phosphomolybdic acid had the same distribution as this acid. It is concluded that the polyvalent phosphomolybdic acid is forming a bridge between the substrate and the dye, holding the dye and probably also the substrate by their cationic groups.
Collapse
|
77
|
Pawełczyk A, Božek F, Grabas K, Chęcmanowski J. Chemical elimination of the harmful properties of asbestos from military facilities. WASTE MANAGEMENT (NEW YORK, N.Y.) 2017; 61:377-385. [PMID: 27979425 DOI: 10.1016/j.wasman.2016.11.041] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/19/2016] [Revised: 11/29/2016] [Accepted: 11/29/2016] [Indexed: 06/06/2023]
Abstract
This work presents research on the neutralization of asbestos banned from military use and its conversion to usable products. The studies showed that asbestos can be decomposed by the use of phosphoric acid. The process proved very effective when the phosphoric acid concentration was 30%, the temperature was 90°C and the reaction time 60min. Contrary to the common asbestos treatment method that consists of landfilling, the proposed process ensures elimination of the harmful properties of this waste material and its transformation into inert substances. The obtained products include calcium phosphate, magnesium phosphate and silica. Chemical, microscopic and X-ray analyses proved that the products are free of harmful fibers and can be, in particular, utilized for fertilizers production. The obtained results may contribute to development of an asbestos utilization technique that fits well into the European waste policy, regulated by the EU waste management law.
Collapse
|
78
|
|
79
|
Scheidt L, Sanabe ME, Collares FM, Leitune VCB, Bresciani E, Diniz MB. Assessment of Enamel Bond Strength of Hypoplastic Primary Teeth. Pediatr Dent 2016; 38:432-436. [PMID: 28206901] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
PURPOSE The purpose of this study was to compare the enamel bond strength of hypoplastic and healthy primary teeth. METHODS Twenty-five hypoplastic teeth (experimental group) and 25 healthy primary teeth (control group) were selected and conditioned with 35 percent orthophosphoric acid before a two-layer adhesive system (Single Bond) was applied. Composite resin (Filtek Z350) was inserted in a single application, two-mm high and one-mm in diameter, and then light-cured for 20 seconds. After being stored in distilled water for 24 hours, the specimens were submitted to a shear bond strength test. Fractures were analyzed under a stereomicroscope. RESULTS No significant differences in bond strength were observed between the experimental group (70.27±20.40 MPa) and control group (67.84±23.37 MPa; P>0.05). However, adhesive fractures were more frequently observed in healthy teeth (72 percent) while hypoplastic teeth presented mixed fractures (60 percent) and enamel cohesive fractures (36 percent). CONCLUSIONS The shear bond strength of the enamel of hypoplastic primary teeth was similar to that of healthy teeth. However, distinct characteristics were observed in the dental samples following fracture.
Collapse
|
80
|
Jang K, You J, Park C, Park H, Choi J, Choi CH, Park J, Lee H, Na S. Ultra-sensitive detection of zinc oxide nanowires using a quartz crystal microbalance and phosphoric acid DNA. NANOTECHNOLOGY 2016; 27:365501. [PMID: 27479871 DOI: 10.1088/0957-4484/27/36/365501] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Recent advancements of nanomaterials have inspired numerous scientific and industrial applications. Zinc oxide nanowires (ZnO NWs) is one of the most important nanomaterials due to their extraordinary properties. However, studies performed over the past decade have reported toxicity of ZnO NWs. Therefore, there has been increasing demand for effective detection of ZnO NWs. In this study, we propose a method for the detection of ZnO NW using a quartz crystal microbalance (QCM) and DNA probes. The detection method is based on the covalent interaction between ZnO NWs and the phosphoric acid group of single-stranded DNA (i.e., linker DNA), and DNA hybridization between the linker DNA and the probe DNA strand on the QCM electrode. Rapid, high sensitivity, in situ detection of ZnO NWs was demonstrated for the first time. The limit of detection was 10(-4) μg ml(-1) in deionized water, which represents a sensitivity that is 100000 times higher than the toxic ZnO NW concentration level. Moreover, the selectivity of the ZnO NW detection method was demonstrated by comparison with other types of nanowires and the method was able to detect ZnO NWs in tap water sensitively even after stored for 14 d in a refrigerator. The performance of our proposed method was sufficient to achieve detection of ZnO NW in the 'real-world' environment.
Collapse
|
81
|
Su HR, Xu PC, Qian WH. [Evaluation of the effect of one-step self etching adhesives applied in pit and fissure sealing]. SHANGHAI KOU QIANG YI XUE = SHANGHAI JOURNAL OF STOMATOLOGY 2016; 25:317-321. [PMID: 27609386] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
PURPOSE To observe the effect of three one-step self etching adhesive systems used in fit and fissure sealant and explore the feasibility of application in caries prevention in school. METHODS Seven hundred and twenty completely erupted mandibular first molars in 360 children aged 7 to 9 years old were chosen. The split-mouth design was used to select one side as the experimental group, divided into A1(Easy One Adper), B1(Adper Easy One), and C1(iBond SE).The contra lateral teeth served as A2,B2 and C2 groups (phosphoric acid). The retention and caries status were regularly reviewed .The clinical effect of the two groups was compared using SPSS19.0 software package for Chi - square test. RESULTS At 3 and 6 months, pit and fissure sealant retention rate in A1 and A2, B1 and B2,C1 and C2 group had no significant difference. At 12 months, sealant retention in A1 and B1 group was significantly lower than A2 and B2 group (P<0.05). No significant difference was found between C1 and C2 groups (P>0.05). At 24 months, sealant retention rate in A1, B1 and C1 group was significantly lower than A2, B2 and C2 group (P<0.05). The caries rate in A1and A2, B1 and B2, C1 and C2 group had no significant difference during different follow-up time (P>0.05). CONCLUSIONS The clinical anticariogenic effect of three kinds of one-step etching adhesives and phosphoric acid etching sealant was similar .One-step self etching adhesive system was recommended for pit and fissure sealant to improve the students' oral health. The long-term retention rate of one-step self etching adhesive system was lower than the phosphoric acid method to long term observation is needed.
Collapse
|
82
|
Tsujimoto A, Barkmeier WW, Takamizawa T, Latta MA, Miyazaki M. The Effect of Phosphoric Acid Pre-etching Times on Bonding Performance and Surface Free Energy with Single-step Self-etch Adhesives. Oper Dent 2016; 41:441-9. [PMID: 27054410 DOI: 10.2341/15-221-l] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
OBJECTIVE The purpose of this study was to evaluate the effect of phosphoric acid pre-etching times on shear bond strength (SBS) and surface free energy (SFE) with single-step self-etch adhesives. METHODS The three single-step self-etch adhesives used were: 1) Scotchbond Universal Adhesive (3M ESPE), 2) Clearfil tri-S Bond (Kuraray Noritake Dental), and 3) G-Bond Plus (GC). Two no pre-etching groups, 1) untreated enamel and 2) enamel surfaces after ultrasonic cleaning with distilled water for 30 seconds to remove the smear layer, were prepared. There were four pre-etching groups: 1) enamel surfaces were pre-etched with phosphoric acid (Etchant, 3M ESPE) for 3 seconds, 2) enamel surfaces were pre-etched for 5 seconds, 3) enamel surfaces were pre-etched for 10 seconds, and 4) enamel surfaces were pre-etched for 15 seconds. Resin composite was bonded to the treated enamel surface to determine SBS. The SFEs of treated enamel surfaces were determined by measuring the contact angles of three test liquids. Scanning electron microscopy was used to examine the enamel surfaces and enamel-adhesive interface. RESULTS The specimens with phosphoric acid pre-etching showed significantly higher SBS and SFEs than the specimens without phosphoric acid pre-etching regardless of the adhesive system used. SBS and SFEs did not increase for phosphoric acid pre-etching times over 3 seconds. There were no significant differences in SBS and SFEs between the specimens with and without a smear layer. CONCLUSION The data suggest that phosphoric acid pre-etching of ground enamel improves the bonding performance of single-step self-etch adhesives, but these bonding properties do not increase for phosphoric acid pre-etching times over 3 seconds.
Collapse
|
83
|
Dong JC, Wen LM, Li R, Li JY. [The influence of different treating agents on the shear bond strength between zirconia and orthodontic brackets]. SHANGHAI KOU QIANG YI XUE = SHANGHAI JOURNAL OF STOMATOLOGY 2016; 25:177-180. [PMID: 27329880] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
PURPOSE To compare the effect of different treating agents on the shear bond strength (SBS) between zirconia and orthodontic brackets. METHODS Fifty zirconia specimens were randomly divided into 5 groups(n=10), and treated with sandblasted and 37% phosphoric acid.Group A was control sample without any treatment; Group B was treated with silane coupling agent; Group C was treated with silane coupling agent and SE Bond; Group D were treated with Z-Prime(TM) Plus; Group E were treated with Z-Prime(TM) Plus+SE Bond. The upper incisor brackets were bonded to each specimen using 3M Transbond light-cured resin adhesive. Each specimen was put into 37°C water, and SBS tests were performed after 24 hours. Then statistical analysis was carried out regarding to the adhesive residual index(ARI) of the zirconia oxide surface after removing the brackets. The surface of zirconia in each group was scanned with scanning electron microscope after surface treatment, and the surface morphology changes were observed, infrared spectra analysis was conducted on zirconia and treating agents. SPSS 17.0 software package was utilized for statistical analysis. RESULTS The mean SBS in each group was as follows: group A (3.12±0.84) MPa; group B (1.92±0.83) MPa; group C (5.26±0.80) MPa; group D (6.54±0.98) MPa; group E (9.47±2.11) MPa. Significant difference existed between each group (P<0.05), group A and B had lower ARI, while ARI in group E was highest. Group D and E achieved effective bond strength. CONCLUSIONS Using Z-Prime(TM) Plus can achieve effective bond strength, which is lower than Z-Prime(TM) Plus combined with SE Bond. It's suggested to use Z-Prime(TM) Plus combined with SE Bond to achieve higher SBS for orthodontic treatment.
Collapse
|
84
|
Liu KL, Zhang XF, Wei X. [Influence of different acid etching modes on bond strengths to non-carious sclerotic dentin]. SHANGHAI KOU QIANG YI XUE = SHANGHAI JOURNAL OF STOMATOLOGY 2016; 25:38-41. [PMID: 27063306] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
PURPOSE To evaluate the effect of different acid etching modes on bond strength between composite resin and non-carious sclerotic dentin, and to provide references for clinical application. MOTHODS Thirty premolars with naturally-occurring non-carious cervical lesions were divided into 2 groups based on self-etch adhesive system AdperTM Easy one (AEO) and total-etch adhesive system AdperTM Single Bond2 (ASB2). Each group was further divided into 3 subgroups (ASB21, ASB22, ASB23, AEO1, AEO2, AEO3) and subjected to the following processing: ASB21 subgroup was etched for 15 s with 35% phosphoric acid and coated with binder for 15 s; ASB22 subgroup was etched for 30 s with 35% phosphoric acid and coated with binder for 15 s; ASB23 subgroup was etched for 15 s with 35% phosphoric acid and coated with binder for 30 s; AEO1 subgroup was only etched with binder for 20 s; AEO2 subgroup was etched with binder for 40 s; AEO3 subgroup was etched for 15 s with 35% phosphoric acid and coated with binder for 20 s. The samples were restored with composite resin; 24 h after saved in distilled water at room temperature, the teeth were cut into dumbbell-shaped specimens with surface areas of approximately 1.0 mm2. The microtensile bond strength (μTBS) was detected and evaluated by one-way ANOVA and SNK-q test using SPSS 17.0 software package. RESULTS μTBS was given in MPa: AEO3>ASB22>ASB23>ASB21>AEO2>AEO1, AEO3 resulted in statistically highest bond strength and AEO1 had the lowest bond strength (P<0.05), ASB22 acquired bond strength just lower than AEO3 (P<0.05). CONCLUSIONS Use of total-etch adhesive system increasing the etching time of phosphoric time can enhance bond strength. For self-etch adhesive system,both duplicated the time of adhesive treatment and use of phosphoric acid can improve the bond strength. Use of phosphoric acid to etch for 15 s and coated with self-etch adhesive system for 20 s achieved the highest bond strength. In either self-etch or total-etch adhesive system, use of phosphoric acid to etch for 15 s and coated with self-etch adhesive system for 20 s achieved optimal bond strength, there was the lowest bond strength when the self-etch adhesive system used as recommended time.
Collapse
|
85
|
Lu S, Zhao S, Sun Y, Gao Y, Li X, Chen J. [Analysis of type-I collagen fibrils and chondroitin sulfate distribution in human dentin by confocal laser scanning microscopy combined with dual immunofluorescent labeling technique]. ZHONGHUA KOU QIANG YI XUE ZA ZHI = ZHONGHUA KOUQIANG YIXUE ZAZHI = CHINESE JOURNAL OF STOMATOLOGY 2015; 50:746-750. [PMID: 26887400] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
OBJECTIVE To introduce the method of dual immunofluorescence labeling of human dentin matrix without demineralization of the whole dentin fragments, and to analyze the distribution of type-I collagen fibrils and chondroitin sulfate in human dentin. METHODS Forty 30 µm- thick middle coronal dentin sections were obtained from 8 freshly extracted human third molars and etched with 37% phosphoric acid(PA) gel for 15 s. After preconditioning with or without tosyl- phenylalanyl chloromethyl ketone(TPCK) treated trypsin digestion, sections were subjected to dual immunofluorescent labeling and scanned by confocal laser scanning microscopy to identify the type-I collagen fibrils and chondroitin sulfate. RESULTS Chondroitin sulfate was localized in the lumens of the dentin tubules and peritubular dentin, while the type-I collagen fibrils were localized in intertubular dentin and peritubular dentin. After preconditioning with TPCK treated trypsin digestion, the red fluorescence was decreased or disappeared. CONCLUSIONS The dual immunofluorescence labeling methodology can be used to study the human dentin matrix without demineralization of the whole dentin fragments. Chondroitin sulfate was localized in the lumens of the dentin tubules and peritubular dentin, while the type-I collagen fibrils were localized in intertubular dentin and peritubular dentin.
Collapse
|
86
|
Zhang Y, Liu YH, Zhou YS, Chung KH. [Influence of carbodiimide-ethanol solution surface treatment on dentin microtensile bond strength]. BEIJING DA XUE XUE BAO. YI XUE BAN = JOURNAL OF PEKING UNIVERSITY. HEALTH SCIENCES 2015; 47:825-828. [PMID: 26474624] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
OBJECTIVE To evaluate the microtensile bond strength changes and patterns of fractures of the bonding interface after dentine surface treatment with carbodiimide-ethanol solution. METHODS 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide (EDC) dissolved in ethanol was diluted into different concentrations of 2, 1, 0.3, 0.1 and 0.01 mol/L EDC-ethanol solutions. Twenty-eight caries-free extracted human third molars were ground metallurgically to prepare flat occlusal mid-coronal dentin surfaces and etched with 35% (mass fraction) phosphoric acid gel. Then they were treated with EDC-ethanol solution for 60 s before the bonding procedure and randomly divided into five experimental groups corresponding to the tested EDC-ethanol concentrations. The ethanol treated and no pre-treated surfaces were used as controls. Single Bond 2 adhesive was applied and resin composite disk was stacked on the treated dentine surface. The teeth with resin composite disks were stored in water at room temperature for 24 h and then sectioned longitudinally to produce stick specimens for microtensile bond strength test. Fracture patterns were observed with a stereomicroscope. RESULTS The dentin surfaces pre-treated with 2 mol/L [(22.17±13.31) MPa] and 1 mol/L [(45.31±17.80) MPa] EDC-ethanol solutions resulted in statistically significant lower bond strength value (P<0.05). Increasing numbers of fracture pattern at the resin-dentin interface were also found in this two groups with percentages of 81.2% and 41.3% respectively. No significant difference was observed in the groups with 0.3, 0.1, 0.01 mol/L EDC surface treatment (P>0.05). CONCLUSION No significant difference of immediate bond strengths was found in the 0.3, 0.1, 0.01 mol/L groups compared with the control group. EDC-ethanol solution surface treatment with concentrations of 2 mol/L and 1 mol/L resulted in decreasing of the bonding strength.
Collapse
|
87
|
Nieminen HJ, Ylitalo T, Karhula S, Suuronen JP, Kauppinen S, Serimaa R, Hæggström E, Pritzker KPH, Valkealahti M, Lehenkari P, Finnilä M, Saarakkala S. Determining collagen distribution in articular cartilage using contrast-enhanced micro-computed tomography. Osteoarthritis Cartilage 2015; 23:1613-21. [PMID: 26003951 PMCID: PMC4565718 DOI: 10.1016/j.joca.2015.05.004] [Citation(s) in RCA: 47] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/26/2014] [Revised: 05/11/2015] [Accepted: 05/12/2015] [Indexed: 02/02/2023]
Abstract
OBJECTIVE Collagen distribution within articular cartilage (AC) is typically evaluated from histological sections, e.g., using collagen staining and light microscopy (LM). Unfortunately, all techniques based on histological sections are time-consuming, destructive, and without extraordinary effort, limited to two dimensions. This study investigates whether phosphotungstic acid (PTA) and phosphomolybdic acid (PMA), two collagen-specific markers and X-ray absorbers, could (1) produce contrast for AC X-ray imaging or (2) be used to detect collagen distribution within AC. METHOD We labeled equine AC samples with PTA or PMA and imaged them with micro-computed tomography (micro-CT) at pre-defined time points 0, 18, 36, 54, 72, 90, 180, 270 h during staining. The micro-CT image intensity was compared with collagen distributions obtained with a reference technique, i.e., Fourier-transform infrared imaging (FTIRI). The labeling time and contrast agent producing highest association (Pearson correlation, Bland-Altman analysis) between FTIRI collagen distribution and micro-CT -determined PTA distribution was selected for human AC. RESULTS Both, PTA and PMA labeling permitted visualization of AC features using micro-CT in non-calcified cartilage. After labeling the samples for 36 h in PTA, the spatial distribution of X-ray attenuation correlated highly with the collagen distribution determined by FTIRI in both equine (mean ± S.D. of the Pearson correlation coefficients, r = 0.96 ± 0.03, n = 12) and human AC (r = 0.82 ± 0.15, n = 4). CONCLUSIONS PTA-induced X-ray attenuation is a potential marker for non-destructive detection of AC collagen distributions in 3D. This approach opens new possibilities in development of non-destructive 3D histopathological techniques for characterization of OA.
Collapse
|
88
|
Sekiya S, Nagoshi K, Iwamoto S, Tanaka K, Takayama M. Timeframe Dependent Fragment Ions Observed in In-Source Decay Experiments with β-Casein Using MALDI MS. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2015; 26:1588-1598. [PMID: 26148524 DOI: 10.1007/s13361-015-1173-3] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/09/2015] [Revised: 04/18/2015] [Accepted: 04/18/2015] [Indexed: 06/04/2023]
Abstract
The fragment ions observed with time-of-flight (TOF) and quadrupole ion trap (QIT) TOF mass spectrometers (MS) combined with matrix-assisted laser desorption/ionization in-source decay (MALDI-ISD) experiments of phosphorylated analytes β-casein and its model peptide were compared from the standpoint of the residence timeframe of analyte and fragment ions in the MALDI ion source and QIT cell. The QIT-TOF MS gave fragment c-, z'-, z-ANL, y-, and b-ions, and further degraded fragments originating from the loss of neutrals such as H(2)O, NH(3), CH(2)O (from serine), C2H4O (from threonine), and H(3)PO(4), whereas the TOF MS merely showed MALDI source-generated fragment c-, z'-, z-ANL, y-, and w-ions. The fragment ions observed in the QIT-TOF MS could be explained by the injection of the source-generated ions into the QIT cell or a cooperative effect of a little internal energy deposition, a long residence timeframe (140 ms) in the QIT cell, and specific amino acid effects on low-energy CID, whereas the source-generated fragments (c-, z'-, z-ANL, y-, and w-ions) could be a result of prompt radical-initiated fragmentation of hydrogen-abundant radical ions [M + H + H](+) and [M + H - H](-) within the 53 ns timeframe, which corresponds to the delayed extraction time. The further degraded fragment b/y-ions produced in the QIT cell were confirmed by positive- and negative-ion low-energy CID experiments performed on the source-generated ions (c-, z'-, and y-ions). The loss of phosphoric acid (98 u) from analyte and fragment ions can be explained by a slow ergodic fragmentation independent of positive and negative charges.
Collapse
|
89
|
Scheffel DLS, Delgado CC, Soares DG, Basso FG, de Souza Costa CA, Pashley DH, Hebling J. Increased Durability of Resin-Dentin Bonds Following Cross-Linking Treatment. Oper Dent 2015; 40:533-9. [PMID: 25764044 DOI: 10.2341/13-211-l] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
OBJECTIVES This study evaluated the long-term effect of carbodiimide treatments of acid-etched dentin on resin-dentin bond strength of a simplified etch-and-rinse adhesive system. METHODS Forty-eight sound third molars were divided into three groups (n=16) according to the dentin treatment: G1: deionized water; G2: 0.5 mol/L 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide (EDC) applied for 30 seconds; and G3: 0.5 mol/L EDC applied for 60 seconds. Flat dentin surfaces were produced, etched with 37% phosphoric acid for 15 seconds, and then treated with deionized water for 60 seconds or with 0.5 mol/L EDC for 30 or 60 seconds prior to the application of Single Bond 2. Crowns were restored with resin composite, and beam specimens were prepared for microtensile testing. The beams from each group were tested 24 hours or 6 or 12 months after the adhesive procedures. One slab from each tooth was prepared and analyzed for nanoleakage. Bond strength (MPa) data were submitted to analysis of variance and Tukey test (α=0.05). RESULTS The treatment of dentin with 0.5 mol/L EDC for 30 seconds (24.1±6.2 MPa) and 60 seconds (25.5±5.1 MPa) did not negatively affect the immediate bond strength of Single Bond 2 when compared to the control group (24.6±7.3 MPa). Additionally, EDC prevented resin-dentin bond degradation after 12 months in artificial saliva for both periods of treatment. An increased accumulation of silver ions was seen for the control group over time, while a much lower amount of silver grains was observed for the EDC-treated groups. CONCLUSIONS 0.5 mol/L EDC was able to prevent resin-dentin bond degradation after 12 months, especially when applied for 60 seconds.
Collapse
|
90
|
Kalra P, Suprabha BS, Rao A, Shenoy R, Lewis AJ. Bond strength of a sealant to enamel after a cariogenic challenge using three bonding protocols: an in vitro study. JOURNAL OF DENTISTRY FOR CHILDREN (CHICAGO, ILL.) 2015; 82:16-21. [PMID: 25909838] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
PURPOSE The purpose of this study was to evaluate in vitro the tensile bond strength of a resin-based pit and fissure sealant to enamel after a cariogenic challenge using three bonding protocols. METHODS The demineralized tooth specimens were assigned to three groups of equal size: Group 1 (37 percent phosphoric acid gel), Group 2 (total-etch adhesive system), and Group 3 (one-step self-etch adhesive system). After the surface treatment, a resin-based sealant was applied and cured. The specimens were thermocycled and tensile bond strength was measured using a universal testing machine by an investigator who was blinded to the group distribution. RESULTS The mean tensile bond strength was highest with the total-etch adhesive system, which was statistically significant (P<.001). A post hoc test revealed a significant difference between Groups 1 and 2 (P<.001) and Groups 2 and 3 (P<.001), but none between Groups 1 and 3 (P=.44). CONCLUSION The total-etch bonding system resulted in significantly higher tensile bond strength with incipient enamel caries.
Collapse
|
91
|
Gao Y, Zhao S, Wang P, Lu S, Li X, Chen J. [Effect of dentin proteoglycans on the bonding properties of dentin]. ZHONGHUA KOU QIANG YI XUE ZA ZHI = ZHONGHUA KOUQIANG YIXUE ZAZHI = CHINESE JOURNAL OF STOMATOLOGY 2014; 49:753-757. [PMID: 25619297] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
OBJECTIVE To investigate the potential effect of proteoglycan (PG) and glycosaminoglycan (GAG) on the bonding of etch and rinse adhesive to dentin, in order to improve the bonding effect of dentin. METHODS Forty-two extracted molars were used to obtain standard dentin bonding surface, and the specimens were etched for 15 s with 37% phosphoric acid and divided into three groups using a table of random numbers. Then the three groups undergone different incubating procedures as follow: specimens in chondroitinase ABC (C-ABC) group were incubated with C-ABC at 37 °C for 48 h in vibrator. Specimens in trypsin (TRY) group were incubated with trypsin, and specimens in the control group were incubated with deionized water for 48 h in the oscillators. Then specimens in each group were randomly assigned into two subgroups, A (Adper(TM) Single Bond 2) and B (Prime & Bond NT) (n = 7). The microtensile bond strength (µTBS), fracture mode and bonding interface morphology of the specimens were evaluated via microtensile testing, stereo microscope and field emission scanning electron microscopy (FE-SEM) respectively after specimens being incubated in 37 °C water for 24 h. RESULTS The immediate µTBS of C-ABC group bonding with adhesive A and B [(32.9±2.5) and (26.8±2.2) MPa] were significantly lower than that of the control group [(40.7±3.3) and (34.6±3.7) MPa] (P < 0.05). While the immediate µTBS of TRY group [(49.0 ± 3.6) and (44.5 ± 3.0) MPa] were significantly higher than that of the control group(P < 0.05). CONCLUSIONS Dentin PG participates in the dentin bonding process. Removal of PG increased the immediate µTBS of dentin and total etching adhesives, while removal of GAG decreased the immediate µTBS.
Collapse
|
92
|
Li S. [Determination a variety of acidic gas in air of workplace by Ion Chromatography]. ZHONGHUA LAO DONG WEI SHENG ZHI YE BING ZA ZHI = ZHONGHUA LAODONG WEISHENG ZHIYEBING ZAZHI = CHINESE JOURNAL OF INDUSTRIAL HYGIENE AND OCCUPATIONAL DISEASES 2014; 32:774-776. [PMID: 25533373] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
OBJECTIVE To establish a method for determination of a variety of acid gas in the workplace air by Ion Chromatography. (hydrofluoric acid, hydrogen chloride or hydrochloric acid, sulfur anhydride or sulfuric acid, phosphoric acid, oxalic acid). METHOD The sample in workplace air was collected by the porous glass plate absorption tube containing 5 ml leacheate. (Sulfuric acid fog, phosphoric acid aerosol microporous membrane after collection, eluted with 5 ml of eluent.) To separated by AS14+AG14 chromatography column, by carbonate (2.0+1.0) mmol/L (Na(2)CO(3)-NaHCO(3)) as eluent, flow rate of 1 ml/min, then analyzed by electrical conductivity detector. The retain time was used for qualitative and the peak area was used for quantitation. RESULTS The each ion of a variety of acid gas in the air of workplace were excellent in carbonate eluent separation. The linear range of working curve of 0∼20 mg/L. The correlation coefficient r>0.999; lower detection limit of 3.6∼115 µg/L; quantitative limit of 0.012∼0.53 mg/L; acquisition of 15L air were measured, the minimum detection concentration is 0.004 0∼0.13 mg/m(3). The recovery rate is 99.7%∼101.1%. In the sample without mutual interference ions. Samples stored at room temperature for 7 days. CONCLUSION The same analysis method, the detection of various acidic gases in the air of workplace, simple operation, good separation effect, high sensitivity, high detection efficiency, easy popularization and application.
Collapse
|
93
|
Knittelfelder OL, Weberhofer BP, Eichmann TO, Kohlwein SD, Rechberger GN. A versatile ultra-high performance LC-MS method for lipid profiling. J Chromatogr B Analyt Technol Biomed Life Sci 2014; 951-952:119-28. [PMID: 24548922 PMCID: PMC3946075 DOI: 10.1016/j.jchromb.2014.01.011] [Citation(s) in RCA: 126] [Impact Index Per Article: 12.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2013] [Revised: 01/07/2014] [Accepted: 01/08/2014] [Indexed: 11/17/2022]
Abstract
A new UPLC-based untargeted lipidomic approach using a qTOF hybrid mass spectrometer is introduced. The applied binary gradient enables separations of lipid species including constitutional isomeric compounds and low abundant lipid classes such as phosphatidic acid (PA). Addition of phosphoric acid to the solvents improves peak shapes for acidic phospholipids. MS(E) scans allow simultaneous acquisition of full scan data and collision induced fragmentation to improve identification of lipid classes and to obtain structural information. The method was used to investigate the lipidome of yeast.
Collapse
|
94
|
Toledano M, Cabello I, Vílchez MAC, Fernández MA, Osorio R. Surface microanalysis and chemical imaging of early dentin remineralization. MICROSCOPY AND MICROANALYSIS : THE OFFICIAL JOURNAL OF MICROSCOPY SOCIETY OF AMERICA, MICROBEAM ANALYSIS SOCIETY, MICROSCOPICAL SOCIETY OF CANADA 2014; 20:245-256. [PMID: 24160361 DOI: 10.1017/s1431927613013639] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
This study reports physical and chemical changes that occur at early dentin remineralization stages. Extracted human third molars were sectioned to obtain dentin discs. After polishing the dentin surfaces, three groups were established: (1) untreated dentin (UD), (2) 37% phosphoric acid application for 15 s (partially demineralized dentin-PDD), and (3) 10% phosphoric acid for 12 h at 25° C (totally demineralized dentin-TDD). Five different remineralizing solutions were used: chlorhexidine (CHX), artificial saliva (AS), phosphate solution (PS), ZnCl2, and ZnO. Wettability (contact angle), ζ potential and Raman spectroscopy analysis were determined on dentin surfaces. Demineralization of dentin resulted in a higher contact angle. Wettability decreased after immersion in all solutions. ζ potential analysis showed dissimilar performance ranging from -6.21 mV (TDD + AS) up to 3.02 mV (PDD + PS). Raman analysis showed an increase in mineral components after immersing the dentin specimens, in terms of crystallinity, mineral content, and concentration. This confirmed the optimal incorporation and deposition of mineral on dentin collagen. Organic content reflected scarce changes, except in TDD that appeared partially denatured. Pyridinium, as an expression of cross-linking, appeared in all spectra except in specimens immersed in PS.
Collapse
|
95
|
Lanucara F, Chi Hoo Lee D, Eyers CE. Unblocking the sink: improved CID-based analysis of phosphorylated peptides by enzymatic removal of the basic C-terminal residue. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2014; 25:214-225. [PMID: 24297471 PMCID: PMC3899453 DOI: 10.1007/s13361-013-0770-2] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/19/2013] [Revised: 10/08/2013] [Accepted: 10/08/2013] [Indexed: 06/02/2023]
Abstract
A one-step enzymatic reaction for improving the collision-induced dissociation (CID)-based tandem mass spectrometry (MS/MS) analysis of phosphorylated peptides in an ion trap is presented. Carboxypeptidase-B (CBP-B) was used to selectively remove C-terminal arginine or lysine residues from phosphorylated tryptic/Lys-C peptides prior to their MS/MS analysis by CID with a Paul-type ion trap. Removal of this basic C-terminal residue served to limit the extent of gas-phase neutral loss of phosphoric acid (H3PO4), favoring the formation of diagnostic b and y ions as determined by an increase in both the number and relative intensities of the sequence-specific product ions. Such differential fragmentation is particularly valuable when the H3PO4 elimination is so predominant that localizing the phosphorylation site on the peptide sequence is hindered. Improvement in the quality of tandem mass spectral data generated by CID upon CBP-B treatment resulted in greater confidence both in assignment of the phosphopeptide primary sequence and for pinpointing the site of phosphorylation. Higher Mascot ion scores were also generated, combined with lower expectation values and higher delta scores for improved confidence in site assignment; Ascore values also improved. These results are rationalized in accordance with the accepted mechanisms for the elimination of H3PO4 upon low energy CID and insights into the factors dictating the observed dissociation pathways are presented. We anticipate this approach will be of utility in the MS analysis of phosphorylated peptides, especially when alternative electron-driven fragmentation techniques are not available.
Collapse
|
96
|
BENNETT EO, WILLIAMS RP. NUCLEIC ACID PHOSPHORUS CONTENT OFBACILLUS ANTHRACISANDBACILLUS CEREUS. ACTA ACUST UNITED AC 2013; 3:285-91. [PMID: 13855549 DOI: 10.1111/j.1348-0421.1959.tb00125.x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
97
|
Lenzi TL, Guglielmi CDAB, Umakoshi CB, Raggio DP. One-step self-etch adhesive bonding to pre-etched primary and permanent enamel. JOURNAL OF DENTISTRY FOR CHILDREN (CHICAGO, ILL.) 2013; 80:57-61. [PMID: 24011292] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
PURPOSE The purpose of this study was to evaluate the effect of pre-etching enamel with phosphoric acid on the bond strength of a 1-step self-etch adhesive system in primary and permanent teeth. METHODS The enamel of 30 primary molars and 30 permanent molars was ground with wet 600-grit silicon carbide paper, and specimens were randomly assigned according to bonding approach (with or without acid-etching). Half of the teeth received preliminary acid etching with phosphoric acid for 15 seconds before applying the self-etch adhesive system Adper Easy Bond. Polyethylene tubes with an internal diameter of 0.76 mm were placed on the bonded area and filled up with Filtek Z250 resin composite. The microshear bond testing was performed after 24 hours of storage in water at 37°C. Failure mode was evaluated using a stereomicroscope (400X). The microshear bond strength means were analyzed by 2-way analysis of variance and Tukey's post hoc test (P<.05). RESULTS Bond strength to the enamel of primary teeth was significantly lower compared to permanent teeth. Higher microshear bond strength values were obtained when the enamel was pre-etched with phosphoric acid. For all groups, adhesive/mixed failure prevailed. CONCLUSION The preliminary etching of enamel increases the bonding effectiveness for the 1-step self-etch system, regardless of tooth type (primary or permanent).
Collapse
|
98
|
Rathke A, Ostermeier V, Muche R, Haller B. Reconsidering the double etching of enamel: do self-etching primers contaminate phosphoric acid-etched enamel? THE JOURNAL OF ADHESIVE DENTISTRY 2013; 15:107-114. [PMID: 23534014 DOI: 10.3290/j.jad.a28671] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
PURPOSE To evaluate the composite-to-enamel bond following double etching of the enamel using phosphoric acid and different self-etching (SE) bonding systems with and without the application of their respective acidic primers. MATERIALS AND METHODS The enamel surfaces of 90 human molars were ground (600 grit) flat and randomly divided into nine groups (n = 10). Three two-step SE systems (AdheSE, ASE; Clearfil SE Bond, CSE; OptiBond Solo Plus SE, OSE) were tested, both with and without primer application on enamel pre-etched with phosphoric acid under dry bonding conditions. As the controls, the SE systems were applied according to their original directions without pre-etching. All the specimens were built up with a microhybrid composite resin (Arabesk Top). After water storage for 24 h at 37°C, the bonded specimens were sheared to failure in the Zwicki 1120. Etching and failure patterns were evaluated using a scanning electron microscope (SEM). Shear bond strength was analyzed with two-way ANOVA and Tukey's test. Failure modes were analyzed with Fisher's exact test. RESULTS Without pre-etching, CSE showed significantly higher bond strengths than ASE and OSE (p < 0.05). Enamel etching prior to the application of the SE systems tended to result in higher bond strengths, but significantly increased the values only for ASE (p < 0.05). Contamination of the pre-etched enamel with the SE primer decreased the bond strength by values of 19% for ASE (p > 0.05), 36% for CSE (p < 0.05), and 75% for OSE (p < 0.05). SEM analysis showed that omission of the priming step significantly increased the number of cohesive failures within the resin for OSE (p < 0.0001). CONCLUSION Additional etching with phosphoric acid before the application of SE systems does not necessarily result in better enamel bonding, since unavoidable primer contamination of the pre-etched enamel was shown to significantly reduce the bond strength for two of the three systems tested.
Collapse
|
99
|
Sinha S, Vorse KK, Noorani H, Kumaraswamy SP, Varma S, Surappaneni H. Microabrasion using 18% hydrochloric acid and 37% phosphoric acid in various degrees of fluorosis - an in vivo comparision. THE EUROPEAN JOURNAL OF ESTHETIC DENTISTRY : OFFICIAL JOURNAL OF THE EUROPEAN ACADEMY OF ESTHETIC DENTISTRY 2013; 8:454-465. [PMID: 23957044] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
AIMS AND OBJECTIVES The aim of this study was to assess the efficacy of 18% hydrochloric acid and 37% phosphoric acid by an in vivo comparison. METHODS Sixty fluorotic permanent maxillary central incisors from 30 patients were divided into 3 categories. The teeth received 5 seconds (mild fluorosis), 20 seconds (moderate fluorosis) and 30 seconds (severe fluorosis) application of 18% hydrochloric acid on 11 and 37% phosphoric acid on 21. Standardized intraoral photographies were taken immediately before, after, and one month after treatment. Vinyl polysiloxane impression of the patient were made before and after the treatment. A scanning electron microscopic (SEM) evaluation was carried out on the models to judge the surface alterations. Wilcoxon and Mann-Whitney tests were used to verify the hypothesis. RESULTS A statistically significant result was obtained in the reduction of white spot opacities, intensity of stains and the total area occupied by the stains in mild and moderate fluorosis teeth. Results of severe fluorosis had an unpredictable outcome. An SEM evaluation revealed good improvement in the surface texture of mild and moderate fluorosis teeth. Teeth with severe fluorosis showed only a slight improvement. CONCLUSION A microabrasion procedure is effective for treating mild and moderate fluorosis cases.
Collapse
|
100
|
Li B, Wang M, Tan YN, Tong MM, Zhai YJ. [Simultaneous determination of four flavones in root and stem of Cudrania tricuspidata and C. cochinchinensis by HPLC-DAD]. ZHONGGUO ZHONG YAO ZA ZHI = ZHONGGUO ZHONGYAO ZAZHI = CHINA JOURNAL OF CHINESE MATERIA MEDICA 2013; 38:167-170. [PMID: 23672035] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
OBJECTIVE To establish a HPLC-DAD method for the determination of axifolin, naringenin, quercetin and kaempferol in Cudrania tricuspidata and C. cochinchinensis in order to provide a scientific reference for species identification and quality evaluation, by establishing. METHOD The determination was performed by HPLC-DAD on an Agilent C18 column (4.6 mm x 150 mm, 5 microm) by gradient elution (0-15 min, 35%-50% A; 15-30 min, 50% - 65% A) using methanol (A) and 0.1% phosphoric acid (B) as the mobile phase. The flow rate was 1 mL x min(-1). The detection wavelength was 290 nm for taxifolin and naringenin, 365 nm for quercetin and kaempferol with column temperature at 30 degrees C. RESULT The content of axifolin and quercetin in the root of C. tricuspidata were remarkably higher than that in the root of C. cochinchinensis, and the content in stem of C. tricuspidata was also higher than that in the stem of C. cochinchinensis, the content of axifolin and quercetin was variable in different species. The content of naringenin and kaempferol in the root of C. cochinchinensis was visibly higher than that in the root of C. tricuspidata, and the content in the stems of the two herbs was similar, the content of naringenin and kaempferol was visibly variable in different medicinal parts of the herb, but similar between the two herbs. CONCLUSION There's some difference of the content of the four ingredients in different medicinal parts and different herbs, so clinical use should not be confused.
Collapse
|