Pan M, Suárez de Lezo J, Medina A, Romero M, Hernández E, Segura J, Melian F, Wangüemert F, Landin M, Benítez F, Amat M, Velasco F, Torres A. In-laboratory removal of femoral sheath following protamine administration in patients having intracoronary stent implantation. Am J Cardiol 1997; 80:1336-8. [PMID: 9388109 DOI: 10.1016/s0002-9149(97)00676-0] [Citation(s) in RCA: 65] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
Two hundred twenty-eight patients with successful coronary stent implantation were randomized either to protamine administration and femoral sheath removal (group I, n = 117) or no heparin neutralization and delayed sheath removal (group II, n = 111). The hospital stay after treatment was shorter in patients receiving protamine; therefore, protamine use for neutralizing circulating heparin may be safely administered immediately after stent implantation.
Collapse
|
127
|
Roĭtman EV, Dement'eva II, Meshcheriakov AV. [Heparin in surgery and artificial circulation: pro and contra. Is there an alternative?]. ANESTEZIOLOGIIA I REANIMATOLOGIIA 1997:65-9. [PMID: 9511253] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
|
128
|
Kereiakes DJ, Broderick TM, Whang DD, Anderson L, Fye D. Partial reversal of heparin anticoagulation by intravenous protamine in abciximab-treated patients undergoing percutaneous intervention. Am J Cardiol 1997; 80:633-4. [PMID: 9294997 DOI: 10.1016/s0002-9149(97)00437-2] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
Serious hemorrhage and vascular complications after abciximab therapy are associated with elevated activated clotting time values. Our preliminary experience suggests that low-dose intravenous protamine administration is both safe and effective in reducing elevated in-laboratory activated clotting time values and the potential for serious hemorrhage in abciximab-treated patients.
Collapse
|
129
|
Jackson JR, Bolognese B, Kircher CH, Marshall LA, Winkler JD. Modulation of angiogenesis in a model of chronic inflammation. Inflamm Res 1997; 46 Suppl 2:S129-30. [PMID: 9297545 DOI: 10.1007/s000110050139] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023] Open
|
130
|
Ereth MH, Nuttall GA, Klindworth JT, MacVeigh I, Santrach PJ, Orszulak TA, Harmsen WS, Oliver WC. Does the platelet-activated clotting test (HemoSTATUS) predict blood loss and platelet dysfunction associated with cardiopulmonary bypass? Anesth Analg 1997; 85:259-64. [PMID: 9249097 DOI: 10.1097/00000539-199708000-00004] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
Platelet dysfunction is a major cause of bleeding after cardiopulmonary bypass (CPB). No timely, simple, point-of-care determinant of platelet function is available for clinical use. Adding platelet-activating factor to conventional activated clotting time methods (platelet-activated clotting test [PACT]) (HemoSTATUS; Medtronic, Inc., Parker, CO) produces rapid results (<3 min) and may yield a measure of platelet responsiveness and whole blood procoagulant activity. Blood samples were drawn for PACT, platelet count, prothrombin time, activated partial thromboplastin time, and thromboelastogram (TEG) from 200 patients undergoing cardiac surgery. The PACT significantly decreased from the baseline to postprotamine time interval (P < 0.001). The PACT correlated with 4-h mediastinal blood loss (r = -0.30, P = 0.014). The TEG maximum amplitude also correlated with 4-h mediastinal blood loss (r = -0.32, P = 0.003). The PACT had a sensitivity and specificity comparable to routine laboratory coagulation tests in predicting blood loss. The TEG maximum amplitude, however, was more predictive than both the PACT and routine coagulation tests in this respect. The PACT may be a useful indicator of platelet responsiveness or whole blood procoagulant activity, but we did not find it superior to other tests of coagulation function for predicting excessive blood loss after CPB.
Collapse
|
131
|
Gao F, Harris DN, Sapsed-Byrne S, Sharp S. Neurone-specific enolase and Sangtec 100 assays during cardiac surgery: Part I--The effects of heparin, protamine and propofol. Perfusion 1997; 12:163-5. [PMID: 9226703 DOI: 10.1177/026765919701200303] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
Neurone-specific enolase (NSE) and Sangtec 100 (S-100) (Sangtec Medical, Sweden) assays are designed for clotted samples, but when studying cerebral damage following cardiac surgery, perioperative samples will contain heparin and/or protamine. The lipid emulsion propofol is also frequently used during cardiac surgery and could affect the assays. We, therefore, studied the effects of heparin, protamine and propofol on the accuracy of NSE and S-100 assays in five healthy patients. Blood samples were taken and divided into four groups: normal saline was added to group A; heparin to group B; heparin followed by protamine to group C; and propofol to group D. NSE and S-100 concentrations were measured for all samples. Neither heparin, protamine nor propofol affected the accuracy of S-100 and NSE assays; therefore, samples can be taken throughout operations involving cardiopulmonary bypass without influencing the results.
Collapse
|
132
|
Hulin MS, Wakefield TW, Andrews PC, Wrobleski SK, Kadell AM, Downing LJ, Stanley JC. Comparison of the hemodynamic and hematologic toxicity of a protamine variant after reversal of low-molecular-weight heparin anticoagulation in a canine model. LABORATORY ANIMAL SCIENCE 1997; 47:153-60. [PMID: 9150494] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
Using the dog as an animal model, we developed an experimental preparation to compare hemodynamic and hematologic toxicity of anticoagulation reversal. Currently, protamine sulfate reversal of standard unfractionated heparin and low-molecular-weight heparin (LMWH) anticoagulation causes adverse side effects, including decreased systemic mean arterial pressure (MAP), decreased cardiac output (CO), decreased oxygen consumption (VO2), and thrombocytopenia. In addition, standard protamine is only marginally effective at reversing the factor Xa inhibition induced by LMWHs. We have produced protamine-like variant peptides to decrease the adverse responses attributed to standard protamine. The hemodynamic, hematologic, and coagulation effects of standard protamine and the protamine variant (+18RGD) were assessed after reversal of LMWH anticoagulation in anesthetized dogs. Flow probes and vascular catheters were surgically implanted for measurement of hemodynamic parameters including MAP, CO, VO2, and heart rate (HR). Hematologic studies (platelet and white blood cell counts) and coagulation studies (activated clotting time [ACT], activated partial thromboplastin time [aPTT], thrombin clotting time [TCT], antifactor Xa and antifactor IIa values) also were performed. The protamine variant +18RGD was less toxic, induced less thrombocytopenia, and was more effective in anticoagulation reversal than was standard protamine sulfate. Results of this study indicate that the dog may be a useful model for investigating important hemodynamic, hematologic, and coagulation parameters during reversal of LMWH anticoagulation by use of synthetic protamine variants.
Collapse
|
133
|
Castelli R, Cicardi M, Gardinali M, Zingale LC, Savi C, Munari M, Agostoni A. Cardiopulmonary by-pass in a patient with acquired C1 inhibitor deficiency. Int J Artif Organs 1997; 20:175-7. [PMID: 9151154] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
C1 inhibitor (C1-INH) regulates, complement, contact system, coagulation and fibrinolysis. Bleeding complications during cardiopulmonary bypass (CPB) have been described in a deficient patient. We report a 72 year old man affected with acquired C1-INH deficiency who successfully underwent CPB.
Collapse
|
134
|
Belboul A, al-Khaja N. The effect of protamine on the epicardial microflow and the graft flow in open-heart surgery. Perfusion 1997; 12:99-106. [PMID: 9160360 DOI: 10.1177/026765919701200204] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
To evaluate the effect of coronary revascularization on myocardial perfusion and surgical outcome regarding graft flow, we used laser Doppler flowmetry to assess the epicardial microcirculation in patients undergoing coronary artery bypass grafting (CABG) or valve replacement (VR) and electromagnetic flowmetry to measure graft flow in the CABG group. In the CABG group, the preoperative mean laser Doppler flow rate (LDF) in the epicardium of the left ventricle significantly increased at the end of cardiopulmonary bypass (CPB) (22 +/- 7 arbitrary units (AU) to 60 +/- 13 AU, p < 0.001). This value further increased 10 min after protamine infusion (66 +/- 14 AU, p < 0.01), but was significantly reduced 30 min later (51 +/- 14 AU, p < 0.002). Compared to the post-CPB value (34 +/- 10 ml/min) before protamine infusion, the mean graft flow (ml/min) to this area significantly increased 10 min after protamine infusion (41.3 +/- 10 ml/min, p < 0.001) but significantly decreased 30 min later (29 +/- 9 ml/min, p < 0.001). The preoperative mean LDF in the VR group was significantly higher than in the CABG group (p < 0.01). In the CABG group, there was a positive correlation between the LDF and graft flow at the end of CPB (r = 0.788) and 10 (r = 0.767) and 30 (r = 0.784) min after protamine infusion. This study shows that coronary bypass grafting increases the myocardial microcirculation which, together with graft flow, could give an early indication of the effect of surgery on myocardial microcirculation. Furthermore, protamine was found to be one of the factors contributing to graft flow reduction postoperatively and, therefore, newer methods of heparin reversal may be desirable.
Collapse
|
135
|
Hendrikx M, Leunens V, Vandezande E, Wallyn A, Flameng W. The use of a heparin removal device: a valid alternative to protamine. Int J Artif Organs 1997; 20:166-74. [PMID: 9151153] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
PURPOSE Experiments were carried out to test the efficacy and safety of the heparin removal device, a plasmapheresis filter that binds and eliminates heparin, in the context of extracorporeal circulation. PROCEDURES AND FINDINGS Six dogs were put on cardiopulmonary bypass after heparinization. Upon weaning, additional heparin was administered to obtain an activated clotting time above 900s. The animals were connected to the heparin removal device and with flows of 500 ml/min, activated clotting time, activated partial thromboplastin time and plasma heparin concentrations were normalised to baseline after 30 min. Hemodynamic parameters remained unaffected. A slight decrease in red and white blood cell count and in platelets was observed which however recovered spontaneously two hours after the filter procedure. No damage to blood components could be observed. CONCLUSIONS The use of a heparin removal device is as efficient as systemic administration of protamine to reverse the effects of heparinization. It may prevent the adverse reactions linked to protamine administration and therefore be indicated in certain subgroups of patients undergoing cardiopulmonary bypass.
Collapse
|
136
|
Llau JV, Hoyas L, Ezpeleta J, García-Polit J, Barberá M, Santes MJ. [Low molecular weight heparins. Implications in anesthesia and resuscitation]. REVISTA ESPANOLA DE ANESTESIOLOGIA Y REANIMACION 1997; 44:70-8. [PMID: 9148359] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
Low molecular weight heparins are a group of drugs that have only recently been introduced in clinical practice. The are widely used for prophylaxis in thromboembolic disease and are being employed increasingly to treat established venous thrombosis. One way in which these drugs are often used is for prophylaxis in the perioperative period for patients at high risk of developing venous thromboembolism, and the anesthesiologist must therefore be familiar with the main aspects of this application. We review pharmacological characteristics of these drugs as well as the literature on low molecular weight heparins, stressing points of main interest to the anesthesiologist and intensive care recovery unit specialist, namely adverse effects (mainly bleeding) and the implications that use of low molecular weight heparin will have on choice of anesthetic (in particular the dilemma of whether to use local/regional anesthesia).
Collapse
|
137
|
Abstract
During cardiac surgery, steroids are frequently administered before the initiation of cardiopulmonary bypass (CPB), termed "pre-treatment," to reduce "first phase" complement activation during cardiopulmonary bypass (CPB). "Second phase" complement activation also occurs during heparin neutralization with protamine, although the effects of steroid pretreatment on such activation are unknown. This study was performed in patients undergoing coronary artery bypass graft surgery to determine whether high-dose methylprednisolone pretreatment affected complement activation during heparin-protamine interaction after termination of CPB. In eight patients (group MP), methylprednisolone, 30 mg/kg, was administered before CPB commencement, whereas another eight patients received placebo (group C). By using 125I des Arg radioimmunoassay, C3a, C4a, and C5a were measured in the arterial blood samples drawn before and 10 min after administration of protamine. An increase in C3a and C4a was observed in both groups after protamine, suggesting classic pathway activation (delta C3a: group C, 4,484 +/- 3,320; group MP, 1,394 +/- 1,653; delta C4a: group C, 1,810 +/- 731; group MP, 717 +/- 580). C3a and C4a levels were significantly lower in group MP patients after protamine compared with controls [delta C3a, 3,499 +/- 1,826 (p < 0.05); delta C4a, 1,241 +/- 232 (p < 0.05)]. C5a was not detected in any samples. These results demonstrate that the effect of pretreatment persists beyond the period of CPB and that methylprednisolone inhibits second-phase complement activation during heparin-protamine interaction. These findings have implication for patients with severe anaphylactoid reactions to protamine.
Collapse
|
138
|
Wakefield TW, Stanley JC. Intraoperative heparin anticoagulation and its reversal. Semin Vasc Surg 1996; 9:296-302. [PMID: 8958606] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
|
139
|
Bernat A, Hoffmann P, Herbert JM. Antagonism of SR 90107A/Org 31540-induced bleeding by protamine sulfate in rats and mice. Thromb Haemost 1996; 76:715-9. [PMID: 8950779] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
The neutralization by protamine sulfate of bleeding enhancement induced by the potent anti-factor Xa pentasaccharide SR 90107A/Org 31540 and by heparin has been studied in rats and mice. Bleeding, as measured by transection of the tail of anaesthetised rats or mice, was increased following the administration of heparin and very high doses of SR 90107A/Org 31540. In rats, i.v. doses of 0.6 mg/kg heparin or 15 mg/kg SR 90107A/Org 31540 were required to enhance bleeding time to approximately the same extent (5- or 7-fold increase), whereas in mice a 13-fold increase in blood loss was observed with i.v. doses of 3 mg/kg heparin or 10 mg/kg SR 90107A/Org 31540. Protamine sulfate (10 mg/kg i.v.) reduced bleeding in rats and mice induced by both compounds. It also neutralized the anti-factor Xa activity as well as the antithrombotic activity of heparin as observed in venous thrombosis models in both species. However, protamine sulfate neither affected the anti-factor Xa activity nor the antithrombotic activity of SR 90107A/Org 31540 in rats and mice. The present results suggest that protamine sulfate may be regarded as a potential antidote to neutralize bleeding side-effects in cases of SR 90107A/Org 31540 overdosing.
Collapse
|
140
|
Kanbak M, Kahraman S, Celebioglu B, Akpolat N, Ercan S, Erdem K. Prophylactic administration of histamine 1 and/or histamine 2 receptor blockers in the prevention of heparin- and protamine-related haemodynamic effects. Anaesth Intensive Care 1996; 24:559-63. [PMID: 8909666 DOI: 10.1177/0310057x9602400509] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
The efficacy of prophylactic administration of H1 and H2 receptor blockers to prevent adverse haemodynamic responses to heparin and protamine was studied. The control group (n = 10) received no histamine receptor blocker, group H1 (n = 10) received oral terfenadine 60 mg, group H2 (n = 10) received oral ranitidine 300 mg, and group H1+H2 (n = 10) received both terfenadine and ranitidine on the night before the operation and on call to the operating room. Heparin sulphate 300 U/kg was injected directly into the right atrium, and protamine hydrochloride was administered at the conclusion of bypass over at least three minutes through a peripheral route. Following the injection of heparin, plasma histamine-like activity (H-LA) was increased significantly in all four groups. While systolic, diastolic, mean arterial and central venous pressures were decreased significantly in the control group, no significant changes were observed in the H1 and H2 groups. Protamine infusion did not lead to an increase in H-LA. Prophylactic administration of histamine receptor blockers (H1 or H2) attenuated the heparin-induced adverse haemodynamic response but did not change the protamine-related haemodynamic effects. Factors other than histamine may play a major role in protamine induced cardiovascular changes.
Collapse
|
141
|
Kikura M, Lee MK, Levy JH. Heparin neutralization with methylene blue, hexadimethrine, or vancomycin after cardiopulmonary bypass. Anesth Analg 1996; 83:223-7. [PMID: 8694296 DOI: 10.1097/00000539-199608000-00004] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
There are no clinically available alternatives for reversing heparin in protamine-allergic patients. This study examined the ability of methylene blue, hexadimethrine, and vancomycin to reverse circulating heparin so that these compounds can be carefully examined in future placebo-controlled studies in humans. Heparin activity in blood obtained from extracorporeal circuits was reversed by adding protamine (13.5, 27.0, 81.1, 135.1, and 270.3 micrograms/mL), methylene blue (13.5, 27.0, 135.1, 202.7, 270.3, 337.8, 405.4, 473.0, 540.5, and 810.8 micrograms/mL), hexadimethrine (6.8, 13.5, 20.3, 27.0, 81.1, and 135.1 micrograms/mL), or vancomycin (13.5, 27.0, 135.1, 270.3, 540.5, and 810.8 micrograms/mL), and activated clotting times (ACTs) were measured with kaolin (n = 18). Heparinase-ACT was obtained to determine complete reversal. Heparin concentrations were 3.3 +/- 0.3 U/mL with ACT values of 485 +/- 97 s. The ACT at a protamine concentration of 81.1 micrograms/mL and at hexadimethrine concentrations of 81.1 and 135.1 micrograms/mL was not statistically different from heparinase-ACT; however, methylene blue or vancomycin did not reverse the anticoagulation at any concentrations. Hexadimethrine can reverse heparin-induced anticoagulation after cardiopulmonary bypass as well as protamine, although methylene blue or vancomycin did not neutralize heparin in vitro.
Collapse
|
142
|
Bernat A, Herbert JM. Protamine sulphate inhibits pentasaccharide (SR80027)-induced bleeding without affecting its antithrombotic and anti-factor Xa activity in the rat. HAEMOSTASIS 1996; 26:195-202. [PMID: 8872130 DOI: 10.1159/000217207] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
The neutralization of a potent anti-factor Xa pentasaccharide (SR 80027) and heparin-induced bleeding enhancement by protamine sulphate was studied in vivo. Bleeding time, as measured by transection of the tail of anaesthetized rats, increased after the administration of standard heparin and SR 80027. Doses of 0.6 and 2.5 mg/kg of heparin and SR 80027, respectively, were required to enhance blood loss to the same extent (6-fold increase). Protamine sulphate (10 mg/kg i.v.) reduced blood loss induced by both compounds but also neutralized the anti-factor Xa activity as well as the antithrombotic activity of standard heparin measured in a venous thrombosis model. However, protamine sulphate did not affect the anti-factor Xa activity or the antithrombotic activity of SR 80027. These data suggest that protamine sulphate may be an effective antidote for the bleeding side-effects of SR 80027 but they also indicate that the bleeding tendency associated with this type of compounds cannot be attributed to their anti-factor Xa activity.
Collapse
|
143
|
O'Leary CE, Fiori R, Hakim TS. Perioperative distribution of pulmonary vascular resistance in patients undergoing coronary artery surgery. Anesth Analg 1996; 82:958-63. [PMID: 8610906 DOI: 10.1097/00000539-199605000-00012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
This study was undertaken to measure distribution of pulmonary vascular resistance (PVR) perioperatively in patients undergoing coronary artery bypass grafting (CABG) and to examine the effects of cardiopulmonary bypass (CPB) on pulmonary capillary pressure (Pc) relative to wedge pressure (Pw). Pulmonary artery catheters were placed before anesthetic induction in 18 patients scheduled for elective CABG and systemic hemodynamic variables were measured. Pulmonary artery pressure was recorded during balloon inflation and stored for off-line determination of Pc. Data were collected prior to induction (baseline), as well as after induction and intubation, skin incision, sternotomy, protamine administration, and chest closure. At each data point, downstream (capillary plus venous segments) resistance (Rds) contributed approximately 60% of total PVR and did not change significantly during the operation. PVR decreased (P < 0.05) after CPB and protamine administration, primarily due to a decrease in the absolute magnitude of the upstream (arterial) resistance. Administration of large-dose opioid anesthesia had no significant effect (P > 0.05) on total PVR or on segmental distribution of vascular resistance. At all data points, Pc was significantly larger than Pw (P < 0.05). This study demonstrates that perioperative measurement of Pc is feasible, that during CABG under these conditions, relative contribution of arterial and venous resistances remain relatively unchanged, that Pc is always larger than Pw, and that the administration of large-dose opioid anesthesia has a minimal effect on pulmonary vascular hemodynamics.
Collapse
|
144
|
Aldea GS, Zhang X, Memmolo CA, Shapira OM, Treanor PR, Kupferschmid JP, Lazar HL, Shemin RJ. Enhanced blood conservation in primary coronary artery bypass surgery using heparin-bonded circuits with lower anticoagulation. J Card Surg 1996; 11:85-95. [PMID: 8811400 DOI: 10.1111/j.1540-8191.1996.tb00018.x] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
BACKGROUND Despite many advances in blood conservation techniques, a significant proportion of patients undergoing primary coronary revascularization still require homologous transfusions. A comprehensive strategy to diminish perioperative blood loss was developed by integrating many individual components to create an improved blood conservation environment and was prospectively applied to 557 patients undergoing primary coronary artery bypass grafting (CABG) procedures performed in our medical center over a 14-month period. METHODS The first 455 patients were treated with conventional, nonheparinbonded circuits (NHBCs) and full anticoagulation (activated clotting time [ACT] > 480 sec). We wanted to test the hypothesis of whether "tip-to-tip" heparin-bonded circuits (HBCs) used in conjunction with lower anticoagulation (ACT > 280 sec) when added to our current blood conservation environment can further enhance clinical outcomes. We prospectively applied this technique to a consecutive group of patients (n = 102). RESULTS Compared to patients treated with NHBCs, patients treated with HBCs had a significantly lower mediastinal and pleural chest tube output in the first 24 hours (683 +/- 561 mL vs 984 +/- 616 mL, p < 0.00001) were less likely to be transfused (52% vs 68.1%, p < 0.01) and had a lower exposure to different blood donor units (4.1 +/- 8.4 vs 9.3 +/- 10.3, p < 0.000003). There were no complications directly related to HBCs used in conjunction with lower anticoagulation. Morbidity and mortality rates were similar in both treatment groups. CONCLUSION In summary, HBCs in conjunction with lower anticoagulation were safely applied in patients undergoing primary CABG with marked improvement in blood conservation, and should be considered for broader clinical use.
Collapse
|
145
|
Wakefield TW, Hantler CB, Wrobleski SK, Crider BA, Stanley JC. Effects of differing rates of protamine reversal of heparin anticoagulation. Surgery 1996; 119:123-8. [PMID: 8571194 DOI: 10.1016/s0039-6060(96)80157-7] [Citation(s) in RCA: 24] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND Protamine sulfate reversal of heparin anticoagulation may be associated with adverse cardiovascular side effects. The purpose of this study was to determine whether diminished systemic oxygen consumption and hemodynamic changes were more likely to accompany rapid versus slow protamine administration. METHODS Fifteen patients undergoing abdominal aortic aneurysm resection in a prospective randomized double-blinded study received intravenous protamine (1.5 mg/kg) rapidly during a 3-minute period (group I, n = 7) or slowly during a 15-minute period (group II, n = 8). Systemic oxygen consumption (VO2) and hemodynamic parameters were assessed for up to 20 minutes after protamine administration began. RESULTS Blood pressure declines (millimeters of mercury) were greatest in group I with rapid protamine administration (-19 systolic and -9 diastolic) compared with group II with slow protamine administration (-12 systolic and -1 diastolic). Heart rate fell markedly in both groups I and II. Cardiac output (CO) declined in group I at virtually all time periods. Similar CO declines in group II occurred 10 minutes after protamine infusion had begun and persisted for 3 minutes after protamine administration was complete. Maximum VO2 decreases were -16% (60 seconds into protamine infusion) and -13% (1.5 minutes after protamine infusion) in groups I and II, respectively, with statistically significant declines (p < 0.05) occurring only in group I compared with baseline values. Statistically significant differences (p < 0.01), however, were found when mean declines during and after protamine infusion were compared with controls for both CO and VO2 in both groups. CONCLUSIONS Significant declines in systemic VO2 and hemodynamic perturbations accompany protamine reversal of heparin anticoagulation during aortic surgery. Rapid protamine administration increases the magnitude of these adverse responses.
Collapse
|
146
|
Martin P, Bannan S, Ashraf SS. Individualized patient heparinization and protamine reversal. J Thorac Cardiovasc Surg 1996; 111:493-4. [PMID: 8583830 DOI: 10.1016/s0022-5223(96)70469-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
|
147
|
Despotis GJ, Filos KS, Zoys TN, Hogue CW, Spitznagel E, Lappas DG. Factors associated with excessive postoperative blood loss and hemostatic transfusion requirements: a multivariate analysis in cardiac surgical patients. Anesth Analg 1996; 82:13-21. [PMID: 8712388 DOI: 10.1097/00000539-199601000-00004] [Citation(s) in RCA: 45] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
The purpose of this study was to prospectively evaluate whether heparin and protamine doses administered using a standardized protocol based on body weight and activated clotting time values are associated with either transfusion of hemostatic blood products (HBPs) or excessive postoperative bleeding. Analysis using 10 multiple logistic or linear regression models in 487 cardiac surgical patients included perioperative variables that may have an association with either transfusion of HBP and/or excessive postoperative chest tube drainage (CTD). Prolonged duration of cardiopulmonary bypass (CPB), lower pre-CPB heparin dose, lower core body temperature in the intensive care unit, combined procedures, older age, repeat procedures, a larger volume of salvaged red cells reinfused intraoperatively and abnormal laboratory coagulation results (prothrombin time, activated partial thromboplastin time, and platelet count) after CPB were associated with both transfusion of HBP and increased CTD. Female gender, lower total heparin dose, preoperative aspirin use and the number of HBPs administered intraoperatively were associated only with increased CTD, whereas a larger total protamine dose was associated only with perioperative transfusion of HBPs. Preoperative use of warfarin or heparin was not associated with excessive blood loss of perioperative transfusion of HBPs. In contrast to previous studies using bovine heparin, data from the present study do not support the use of reduced doses of porcine heparin during CPB.
Collapse
|
148
|
Nathan N, Mercury P, Denizot Y, Cornu E, Laskar M, Lathelize M, Arnoux B, Feiss P. Effects of a paf-receptor antagonist on hemodynamics during and after cardiopulmonary bypass. J Cardiothorac Vasc Anesth 1995; 9:647-52. [PMID: 8664454 DOI: 10.1016/s1053-0770(05)80224-1] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
OBJECTIVES To assess after cardiopulmonary bypass (CPB) the role of paf-acether (paf), a phospholipid mediator whose injection in animal mimics the hemodynamics observed after CPB. DESIGN Prospective double-blind randomized study. SETTING Single institutional university hospital. PARTICIPANTS 18 patients scheduled to undergo coronary artery bypass graft. INTERVENTIONS 18 patients randomly received a placebo (n = 8) or 120 mg BN52021 (n = 10), a paf-receptor antagonist injected twice just before vascular cannulation and before cross-clamp release. MEASUREMENTS AND MAIN RESULTS Hemodynamic measurements were performed with a pulmonary artery and a radial artery catheter before and after the first injection of BN52021 or placebo, at the end of CPB, 1, 15, and 30 minutes after protamine infusion, then 6 hours and 24 hours postoperatively. BN52021 infusion, did not affect hemodynamic parameters. After CPB, the pulmonary artery pressures, the cardiac index, and the pulmonary artery occlusion pressures were statistically the same between groups. By contrast, the pulmonary vascular resistances (1.5 +/- 0.5 IU v 4.5 +/- 0.6 IU, p < 0.05), the right ventricular systolic work index (5.3 +/- 0.91 g m m-2 v 9.37 +/- 1.02 g m m-2, p < 0.05) and the transpulmonary gradient (4.7 +/- 1.1 mmHg v 12.0 +/- 1.2 mmHg, p < 0.05) were lower in the BN52021 group as compared with the placebo group. After protamine infusion, these differences between groups disappeared. CONCLUSION Because the inotropic and vasodilator therapy and the volume loading were the same between groups, this study suggests that pretreatment with a paf-receptor antagonist improves post-CPB pulmonary resistance. Nevertheless, this beneficial effect is transient without consequences on left ventricular function indices.
Collapse
|
149
|
Hendrice C, Schmartz D, Pradier O, Coron T, Kucharcezwski C, d'Hollander A, Capel P. Effects of aprotinin on blood loss, heparin monitoring tests, and heparin doses in patients undergoing coronary artery bypass surgery. J Cardiothorac Vasc Anesth 1995; 9:245-9. [PMID: 7545449 DOI: 10.1016/s1053-0770(05)80315-5] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
Abstract
OBJECTIVES Evaluation of the effect of aprotinin on heparin monitoring tests, on heparin doses, and on perioperative blood loss in patients undergoing coronary artery bypass grafting. DESIGN Randomized, prospective open study. SETTING The study was performed in the departments of Anaesthesiology and Haematology of the Erasme University Hospital, Brussels. PARTICIPANTS Twenty-six patients undergoing primary coronary artery bypass grafting. INTERVENTIONS Twelve patients received aprotinin, and 14 received no treatment. MEASUREMENT AND MAIN RESULTS Aprotinin significantly reduced blood loss during coronary artery bypass surgery and was associated with a slight reduction in the amount of heparin administered. Activated coagulation time and activated partial thromboplastin time were prolonged by the addition of aprotinin. Activated coagulation time and activated partial thromboplastin time were poorly correlated with heparin assays. On the other hand, two other clotting tests designed to monitor heparin therapy, namely Titrarine (Stago, Asnière, France) and Heptest (Haemachem, St. Louis, MO), gave very good correlation with amidolytic heparin assays and can be used during extracorporeal circulation. Thrombin time showed a good correlation with amidolytic heparin assays after protamine administration and can be useful to detect residual heparin after heparin neutralization by protamine.
Collapse
|
150
|
Subramaniam P, Skillington P, Tatoulis J. Heparin-rebound in the early postoperative phase following cardiopulmonary bypass. THE AUSTRALIAN AND NEW ZEALAND JOURNAL OF SURGERY 1995; 65:331-3. [PMID: 7741676 DOI: 10.1111/j.1445-2197.1995.tb00648.x] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
The incidence of the 'heparin-rebound' phenomenon after protamine neutralization of systemic heparinization required for cardiopulmonary bypass (CPB) was investigated. Heparin-effect was detected in 43% of patients studied at 2 h, 31% at 4 h, and 37% at 8 h after reversal of circuit heparin on CPB. Heparin-rebound was shown to be associated with a small but significant increase in postoperative bleeding which was not of clinical importance.
Collapse
|