201
|
Guzmán-Vázquez de Prada A, Reviejo AJ, Pingarrón JM. A method for the quantification of low concentration sulfamethazine residues in milk based on molecularly imprinted clean-up and surface preconcentration at a Nafion-modified glassy carbon electrode. J Pharm Biomed Anal 2006; 40:281-6. [PMID: 16239091 DOI: 10.1016/j.jpba.2005.07.022] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2005] [Revised: 07/20/2005] [Accepted: 07/20/2005] [Indexed: 10/25/2022]
Abstract
An electrochemical method for the determination of sulfamethazine at a low concentration level (25 microgl(-1)) in milk is reported. The method involves sample clean-up and selective preconcentration of sulfamethazine with a molecularly imprinted polymer (MIP), and a further electrode surface preconcentration of the analyte at a Nafion-coated glassy carbon electrode (GCE). Square wave (SW) oxidative voltammetry of accumulated sulfamethazine was employed for its quantification. Sulfamethazine electrode preconcentration was carried out in 0.1 moll(-1) Britton-Robinson buffer of pH 1.5, and by applying 5 min of accumulation at open circuit. A linear calibration graph was obtained for sulfamethazine at the Nafion-modified GCE over the 1.0x10(-8) to 1.0x10(-6)moll(-1) concentration range, with a detection limit of 6.8x10(-9)moll(-1) (1.9 microgl(-1)). This detection limit is remarkably better than those reported previously in the literature using electroanalytical techniques. Although the detection limit achieved was sufficient to allow the direct determination of sulfamethazine at the concentration level required in milk, a sample clean-up was shown to be necessary to obtain analytically useful SW voltammograms. This was accomplished by processing the deproteinized milk through a cartridge containing a molecularly imprinted polymer for sulfamethazine, also allowing a selective preconcentration of the analyte. Elution of the analyte from the MIP cartridges was carried out with 2 ml of a (9:1) MeOH:acetic acid mixture. Determination of sulfamethazine in milk samples was accomplished by interpolation into a calibration graph constructed with sulfamethazine standard solutions which were subjected to the same procedure than the deproteinized milk samples. Results obtained for five samples, spiked at the 25 microgl(-1) level, showed a mean recovery of (100+/-3)%.
Collapse
|
202
|
Campuzano S, Pedrero M, Montemayor C, Fatás E, Pingarrón JM. Characterization of alkanethiol-self-assembled monolayers-modified gold electrodes by electrochemical impedance spectroscopy. J Electroanal Chem (Lausanne) 2006. [DOI: 10.1016/j.jelechem.2005.09.007] [Citation(s) in RCA: 118] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
203
|
Serra B, Morales MD, Reviejo AJ, Hall EH, Pingarrón JM. Rapid and highly sensitive electrochemical determination of alkaline phosphatase using a composite tyrosinase biosensor. Anal Biochem 2005; 336:289-94. [PMID: 15620894 DOI: 10.1016/j.ab.2004.10.039] [Citation(s) in RCA: 51] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2004] [Indexed: 10/26/2022]
Abstract
The use of an amperometric graphite-Teflon composite tyrosinase biosensor for the rapid monitoring of alkaline phosphatase (ALP), with no need of an incubation step and using phenyl phosphate as the substrate, is reported. Phenol generated by the action of ALP is monitored at the tyrosinase composite electrode through the electrochemical reduction of the o-quinone produced to catechol, which produces a cycle between the tyrosinase substrate and the electroactive product, giving rise to the amplification of the biosensor response and to the sensitive detection of ALP. The current was measured at -0.10 V 5 min after the addition of ALP. As a compromise between high ALP activity and high sensitivity for the detection of phenol, a pH of 8.5 was chosen. The substrate concentration was also optimized. A linear calibration plot was obtained for ALP between 2.0 x 10(-13) and 2.5 x 10(-11), with a detection limit of 6.7 x 10(-14) M. Different types of milk were analyzed with good results, using an extremely simple and rapid procedure.
Collapse
|
204
|
|
205
|
Agüí L, Vega-Montenegro D, Yáñez-Sedeño P, Pingarrón JM. Rapid voltammetric determination of nitroaromatic explosives at electrochemically activated carbon-fibre electrodes. Anal Bioanal Chem 2005; 382:381-7. [PMID: 15830191 DOI: 10.1007/s00216-004-3017-z] [Citation(s) in RCA: 43] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2004] [Revised: 11/26/2004] [Accepted: 12/01/2004] [Indexed: 10/25/2022]
Abstract
The electrochemical behaviour of some nitroaromatic explosives (2,4,6-trinitrotoluene, TNT; 2,6-dinitrotoluene, 2,6-DNT; 2-nitrotoluene, 2-NT; 2-amino-4,6-dinitrotoluene, 2-A-4,6-DNT; 3,5-dinitroaniline, 3,5-DNA; and nitrobenzene, NB) at electrochemically activated carbon-fibre microelectrodes is reported. Electrochemical activation of such electrode material by repeated square-wave (SW) voltammetric scans between 0.0 and +2.6 V versus Ag/AgCl, produced a dramatic increase in the cathodic response from these compounds. This is attributed to the increase of the carbon-fibre surface area, because of its fracture, and the appearance of deep fissures along the main fibre axis into which the nitroaromatic compounds penetrate. Based on the important contribution of adsorption and/or thin layer electrolysis to the total voltammetric response, a SW voltammetric method for rapid detection of nitroaromatic explosives was developed. No interference was found from compounds such as hydrazine, phenolic compounds, carbamates, triazines or surfactants. The limits of detection obtained are approximately 0.03 microg mL(-1) for all the nitroaromatic compounds tested. The method was applied for the determination of TNT in water and soil spiked samples; recoveries were higher than 95% in all cases.
Collapse
|
206
|
Mena ML, Yáñez-Sedeño P, Pingarrón JM. A comparison of different strategies for the construction of amperometric enzyme biosensors using gold nanoparticle-modified electrodes. Anal Biochem 2005; 336:20-7. [PMID: 15582554 DOI: 10.1016/j.ab.2004.07.038] [Citation(s) in RCA: 144] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2004] [Indexed: 11/15/2022]
Abstract
A comparison of the analytical performances of several enzyme biosensor designs, based on the use of different tailored gold nanoparticle-modified electrode surfaces, is discussed. Glucose oxidase (GOx) and the redox mediator tetrathiafulvalene were coimmobilized in all cases by crosslinking with glutaraldehyde. The biosensor designs tested were based on the use of (i) colloidal gold (Au(coll)) bound on cysteamine (Cyst) monolayers self-assembled on a gold disk electrode (AuE) and (ii) glassy carbon electrodes (GCEs) modified with electrodeposited gold nanoparticles (nAu). The results obtained with these designs were compared with those provided by a GOx/Cyst-AuE and a GOx/MPA-AuE. In the second case (ii), configurations based on direct immobilization of GOx on nAu (GOx/nAu-GCE) or on Cyst or MPA self-assembled monolayers (SAMs) previously bound on gold nanoparticles (GOx/Cyst-nAu-GCE or GOx/MPA-nAu-GCE, respectively) were compared. The analytical characteristics of glucose calibration plots and the kinetic parameters of the enzyme reaction were compared for all of the biosensors tested. The GOx/Au(coll)-Cyst-AuE design showed a sensitivity for glucose determination higher than that achieved with GOx/Cyst-AuE and GOx/Au(coll)-Cyst/Cyst-AuE and similar to that achieved with GOx/MPA-AuE. Moreover, the useful lifetime of one single GOx/Au(coll)-Cyst-AuE was 28 days, remarkably longer than that of the other GOx biosensor designs.
Collapse
|
207
|
Campuzano S, Loaiza OA, Pedrero M, de Villena FJM, Pingarrón JM. An integrated bienzyme glucose oxidase–fructose dehydrogenase–tetrathiafulvalene-3-mercaptopropionic acid–gold electrode for the simultaneous determination of glucose and fructose. Bioelectrochemistry 2004; 63:199-206. [PMID: 15110273 DOI: 10.1016/j.bioelechem.2003.10.019] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2003] [Revised: 10/06/2003] [Accepted: 10/08/2003] [Indexed: 10/26/2022]
Abstract
A bienzyme biosensor for the simultaneous determination of glucose and fructose was developed by coimmobilising glucose oxidase (GOD), fructose dehydrogenase (FDH), and the mediator, tetrathiafulvalene (TTF), by cross-linking with glutaraldehyde atop a 3-mercaptopropionic acid (MPA) self-assembled monolayer (SAM) on a gold disk electrode (AuE). The performance of this bienzyme electrode under batch and flow injection (FI) conditions, as well as an amperometric detection in high-performance liquid chromatography (HPLC), are reported. The order of enzyme immobilisation atop the MPA-SAM affected the biosensor amperometric response in terms of sensitivity, with the immobilisation order GOD, FDH, TTF being selected. Similar analytical characteristics to those obtained with single GOD or FDH SAM-based biosensors for glucose and fructose were achieved with the bienzyme electrode, indicating that no noticeable changes in the biosensor responses to the analytes occurred as a consequence of the coimmobilisation of both enzymes on the same MPA-AuE. The suitability of the bienzyme biosensor for the analysis of real samples under flow injection conditions was tested by determining glucose in two certified serum samples. The simultaneous determination of glucose and fructose in the same sample cannot be performed without a separation step because at the detection potential used (+0.10 V), both sugars show amperometric response. Consequently, HPLC with amperometric detection at the TTF-FDH-GOD-MPA-AuE was accomplished. Glucose and fructose were simultaneously determined in honey, cola softdrink, and commercial apple juice, and the results were compared with those obtained by using other reference methods.
Collapse
|
208
|
Guzmán A, Agüí L, Pedrero M, Yáñez-Sedeño P, Pingarrón JM. Flow injection and HPLC determination of furosemide using pulsed amperometric detection at microelectrodes. J Pharm Biomed Anal 2003; 33:923-33. [PMID: 14656583 DOI: 10.1016/s0731-7085(03)00422-9] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
The flow-injection and HPLC determination of the diuretic drug furosemide using pulsed amperometric detection (PAD) at cylindrical carbon fibre microelectrodes (CFMEs) is reported. Experimental conditions such as pH (6.5) and buffer concentration (0.05 mol l(-1) HPO4(2-)/H2PO4(-)) were optimized using square-wave voltammetry (SWV). Repetitive flow-injection amperometric measurements at +1.25 V for furosemide showed a continuous decrease in the peak current, probably as a consequence of the microelectrode surface fouling. However, a suitable amperometric detection of furosemide was achieved using a PAD program consisting of a two-step potential waveform with alternating anodic and cathodic polarization. The anodic (detection) potential was +1.25 V (time of application 0.1 s), and the cathodic (cleaning) potential was -0.20 V (t=0.2 s). A linear calibration graph was obtained for furosemide in the 5.0 x 10(-7)-1.0 x 10(-4) mol l(-1) concentration range, with a limit of detection of 1.7 x 10(-7) mol l(-1). HPLC-PAD at carbon fibre microelectrodes was used for the determination of furosemide in the presence of several thiouracil drugs and oxytetracycline (OTC). The mobile phase selected was a 25:75 acetonitrile:5.0 x 10(-3) mol l(-1) NaH2PO4 (pH 5.0) mixture. A linear calibration graph was obtained for furosemide in the 1-100 microM range, with a limit of detection of 0.55 microM. The usefulness of this method for the determination of furosemide in real samples was evaluated by performing the analysis of commercial milk samples spiked with furosemide at a concentration level of 4.5 x 10(-7) mol l(-1) (150 ng ml(-1)), as well as with other thiouracil drugs and OTC. A mean recovery of 95+/-5% furosemide was obtained.
Collapse
|
209
|
Campuzano S, Gálvez R, Pedrero M, Manuel de Villena FJ, Pingarrón JM. An integrated electrochemical fructose biosensor based on tetrathiafulvalene-modified self-assembled monolayers on gold electrodes. Anal Bioanal Chem 2003; 377:600-7. [PMID: 12898106 DOI: 10.1007/s00216-003-2123-7] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2003] [Revised: 06/10/2003] [Accepted: 06/17/2003] [Indexed: 11/29/2022]
Abstract
An integrated amperometric fructose biosensor based on a gold electrode (AuE) modified with a self-assembled monolayer (SAM) of 3-mercaptopropionic acid (MPA) on which fructose dehydrogenase (FDH) and the mediator tetrathiafulvalene (TTF) are co-immobilized by cross-linking with glutaraldehyde is reported. Variables concerning the behavior of the biosensor were optimized by taking the slope value obtained for the fructose calibration plot in the 0.1-1.0 mM concentration range as a criterion of selection. At an applied potential of +0.20 V, a good repeatability of such slope values (RSD=6.7%, n=10) was obtained with no need to apply a cleaning or pretreatment procedure to the modified electrode. Moreover, results from five different TTF-FDH-MPA-AuEs yielded a RSD of 5.8%. The useful lifetime of one single biosensor was approximately 30 days, exhibiting a 93% of the original response on the 33rd day. A linear calibration graph was obtained for fructose over the 1.0 x 10(-5)-1.0 x 10(-3) M range, with a limit of detection of 2.4 x 10(-6) M. The effect of potential interferents was evaluated. The TTF-FDH-MPA-AuE also performed well in the flow-injection mode. The biosensor was used for the determination of fructose in real samples, and the results compared with those provided by using a commercial enzyme test kit.
Collapse
|
210
|
Campuzano S, Serra B, Pedrero M, Villena FMD, Pingarrón JM. Amperometric flow-injection determination of phenolic compounds at self-assembled monolayer-based tyrosinase biosensors. Anal Chim Acta 2003. [DOI: 10.1016/s0003-2670(03)00919-x] [Citation(s) in RCA: 116] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
211
|
de Prada AGV, Peña N, Mena ML, Reviejo AJ, Pingarrón JM. Graphite-Teflon composite bienzyme amperometric biosensors for monitoring of alcohols. Biosens Bioelectron 2003; 18:1279-88. [PMID: 12835046 DOI: 10.1016/s0956-5663(03)00074-5] [Citation(s) in RCA: 39] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
Composite graphite-Teflon electrodes, in which the enzymes alcohol oxidase (AOD) and horseradish peroxidase (HRP), as well as the mediator ferrocene, are incorporated into the electrode matrix, are reported for the reliable monitoring of alcohols in food and beverages. The bienzyme electrodes are constructed by simple physical inclusion of the enzymes and the mediator in the bulk of graphite-70% Teflon rigid cylindrical pellets. The composite biosensors are robust and reusable because of the renewability of the electrode surface by polishing. Reproducible amperometric responses at 0.00 V were obtained with different electrodes constructed from the same pellet and from different pellets. No significant loss of the enzymes activities was found after at least 3 months of storage at 0 degrees C. The detection limits obtained by amperometry in stirred solutions can be advantageously compared with those achieved with commercial sensors for alcohols. The bienzyme electrodes are suitable to be used under flow-injection conditions, as well as for amperometric detection in HPLC. The bioelectrodes were employed for the determination of ethanol in beers, wines and liquors, using both batch- and flow-injection modes, and for the determination of methanol in wines and liquors by HPLC with amperometric detection. Only a dilution of the beverages was needed as sample treatment in all cases.
Collapse
|
212
|
Mena ML, Agüí L, Martinez-Ruiz P, Yáñez-Sedeño P, Reviejo AJ, Pingarrón JM. Molecularly imprinted polymers for on-line clean up and preconcentration of chloramphenicol prior to its voltammetric determination. Anal Bioanal Chem 2003; 376:18-25. [PMID: 12677345 DOI: 10.1007/s00216-003-1846-9] [Citation(s) in RCA: 40] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2002] [Revised: 01/21/2003] [Accepted: 01/22/2003] [Indexed: 10/20/2022]
Abstract
The performance of a molecularly imprinted polymer (MIP) as a selective solid-phase extraction sorbent for the clean-up and preconcentration of the antibiotic chloramphenicol is described. The MIP was prepared using chloramphenicol as the template, (diethylamino)ethyl methacrylate as the functional monomer, and ethylene glycol dimethacrylate as the cross-linking monomer, and using tetrahydrofuran as the solvent. Detection of chloramphenicol was carried out by square-wave voltammetry at electrochemically activated carbon fiber microelectrodes. Chloramphenicol was eluted from the MIP microcolumn with methanol. Different experimental variables (sample pH, eluent volume, analyte and eluent flow rates and sample volume) associated with the rebinding/elution process were optimized. For a 250 mL sample, a nominal enrichment factor of 500 was attained, and for a chloramphenicol concentration of 3.0x10(-8) mol L(-1) (9.7 microg L(-1)) a recovery of 96+/-4% was obtained. A range of linearity for chloramphenicol between 3.0x10(-8) and 1.0x10(-5) mol L(-1) was obtained by loading 17 mL of analyte solutions of different concentration, eluting with 0.5 mL methanol, evaporating under a stream of nitrogen and dissolving the residue in phosphate buffer of pH 7.8. The MIP selectivity was evaluated by checking several substances with similar molecular structures to that of chloramphenicol. The applicability of the MIP for both clean up and preconcentration was demonstrated by determining chloramphenicol in ophthalmic solutions and spiked milk at different concentration levels.
Collapse
|
213
|
Campuzano S, Gálvez R, Pedrero M, de Villena FM, Pingarrón JM. Preparation, characterization and application of alkanethiol self-assembled monolayers modified with tetrathiafulvalene and glucose oxidase at a gold disk electrode. J Electroanal Chem (Lausanne) 2002. [DOI: 10.1016/s0022-0728(02)00753-2] [Citation(s) in RCA: 89] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
214
|
Serra B, Jiménez S, Mena ML, Reviejo AJ, Pingarrón JM. Composite electrochemical biosensors: a comparison of three different electrode matrices for the construction of amperometric tyrosinase biosensors. Biosens Bioelectron 2002; 17:217-26. [PMID: 11839475 DOI: 10.1016/s0956-5663(01)00269-x] [Citation(s) in RCA: 61] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
A comparison of the behaviour of three different rigid composite matrices for the construction of amperometric tyrosinase biosensors, which are widely used for the detection of phenolic compounds, is reported. The composite electrode matrices were, graphite-Teflon; reticulated vitreous carbon (RVC)-epoxy resin; and graphite-ethylene/propylene/diene (EPD) terpolymer. After optimization of the experimental conditions, different aspects regarding the stability of the three composite tyrosinase electrode designs were considered and compared. A better reproducibility of the amperometric responses was found with the graphite-EPD electrodes, whereas a longer useful lifetime was observed for the graphite-Teflon electrodes. The kinetic parameters of the tyrosinase reaction were calculated for eight different phenolic compounds, as well as their corresponding calibration plots. The general trend in sensitivity was graphite-EPD>graphite-Teflon>>RVC-epoxy resin. A correlation between sensitivity and the catalytic efficiency of the enzyme reaction for each phenolic substrate was found. Furthermore, differences in the sensitivity order for the phenolic compounds were observed among the three biocomposite electrodes, which suggests that the nature of the electrode matrix influences the interactions in the tyrosinase catalytic cycle.
Collapse
|
215
|
Domínguez R, Serra B, Reviejo AJ, Pingarrón JM. Chiral analysis of amino acids using electrochemical composite bienzyme biosensors. Anal Biochem 2001; 298:275-82. [PMID: 11700983 DOI: 10.1006/abio.2001.5371] [Citation(s) in RCA: 59] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
The construction and performance of bienzyme amperometric composite biosensors for the selective determination of l- or d-amino acids is reported. D- or L-Amino acid oxidase, horseradish peroxidase, and the mediator ferrocene were coimmobilized by simple physical inclusion into the bulk of a graphite-70% Teflon electrode matrix. Working conditions including amino acid oxidase loading and pH were optimized. Studies on the repeatability of the amperometric response obtained at +0.00 V, with and without regeneration of the electrode surface by polishing, on the useful lifetime of one single biosensor and on the reproducibility in the fabrication of different biosensors illustrate the robustness of the bioelectrodes design. Calibration plots by both amperometry in stirred solutions and flow injection with amperometric detection were obtained for L-arginine, L-phenylalanine, L-leucine, L-methionine, L-tryptophan, D-leucine, D-methionine, D-serine, and D-valine. Differences in sensitivity were discussed in terms of the hydrophobicity of the substrate and of the electrode surface. The bienzyme composite electrode was applied to the determination of L- and D-amino acids in racemic samples, as well as to the estimation of the L-amino acids content in muscatel grapes.
Collapse
|
216
|
Guzmán A, Agüí L, Pedrero M, Yáñez-Sedeño P, Pingarrón JM. Voltammetric Determination of Methylthiouracil in Animal Feed Using Carbon Fiber Microelectrodes. ELECTROANAL 2001. [DOI: 10.1002/1521-4109(200111)13:16<1301::aid-elan1301>3.0.co;2-p] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
217
|
Pedrero M, Salas P, Gálvez R, Manuel de Villena FJ, Pingarrón JM. Ruthenium and ruthenium dioxide-modified graphite-ethylene/ propylene/diene and graphite-teflon composite electrodes as amperometric flow detectors. Application to the determination of methionine. FRESENIUS' JOURNAL OF ANALYTICAL CHEMISTRY 2001; 371:507-13. [PMID: 11760061 DOI: 10.1007/s002160101032] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
The flow injection amperometric performance of solid composite graphite electrodes with ethylene/propylene/diene (EPD) or Teflon as binding agents, and with Ru or RuO2 particles as electrocatalytic modifiers has been compared. Both, Ru and RuO2 modified electrodes exhibited electrocatalytic properties on the methionine oxidation process in alkaline media. The electrodes composition and the hydrodynamic and chemical variables were optimized. Graphite-EPD (GEPD) electrodes showed a better analytical performance than graphite-Teflon (GPTFE) electrodes. Furthermore, a better sensitivity, repeatability and reproducibility was observed for RuO2-GEPD electrodes when compared with Ru-GEPD electrodes. At an applied potential of +0.50 V, a detection limit for methionine of 4.8x10(-5) mol L(-1), similar to those reported in the literature for other RuO2-modified electrodes, was obtained. The analytical applicability of RuO2-GEPD electrodes was demonstrated by determining methionine in a complex pharmaceutical formulation.
Collapse
|
218
|
Peña N, Reviejo AJ, Pingarrón JM. Detection of phenolic compounds in flow systems based on tyrosinase-modified reticulated vitreous carbon electrodes. Talanta 2001; 55:179-187. [PMID: 18968360] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2001] [Revised: 04/09/2001] [Accepted: 04/11/2001] [Indexed: 05/27/2023]
Abstract
The fabrication and performance of a reticulated vitreous carbon (RVC)-based tyrosinase flow-through electrode, in which the enzyme was covalently immobilized, is reported. The bioelectrode was tested as an amperometric detector for phenolic compounds. Variables affecting the construction of the enzyme flow-through electrode such as the RVC chemical pretreatment procedure, the enzyme immobilization method in the RVC matrix, the enzyme loading and the pH value of the buffer solution used, were optimized by flow-injection with amperometric detection. A good immobilization of the enzyme in the RVC matrix, in spite of the hydrodynamic conditions, was found. The same tyrosinase-RVC electrode could be used with no significant loss of the amperometric response for around 20 days, and reproducible responses could be achieved with different electrodes constructed in the same manner. Moreover, the operational stability of the bioelectrode was tested under continuous monitorization conditions. Calibration plots by flow injection with amperometric detection at -0.20 V were obtained for phenol, 2,4-dimethylphenol; 3-chlorophenol; 4-chlorophenol; 4-chloro-3-methylphenol and 2-aminophenol, with detection limits ranging from 2 mug l(-1) (4-chloro-3-methylphenol) to 2 mg l(-1).
Collapse
|
219
|
Peña N, Ruiz G, Reviejo AJ, Pingarrón JM. Graphite-teflon composite bienzyme electrodes for the determination of cholesterol in reversed micelles. Application to food samples. Anal Chem 2001; 73:1190-5. [PMID: 11305650 DOI: 10.1021/ac0012243] [Citation(s) in RCA: 57] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
A bienzyme amperometric composite biosensor for the determination of free and total cholesterol in food samples is reported. Cholesterol oxidase and horseradish peroxidase, together with potassium ferrocyanide as a mediator, are incorporated into a graphite-70% Teflon matrix. The compatibility of this biosensor design with predominantly nonaqueous media allows the use of reversed micelles as working medium. The reversed micelles are formed with ethyl acetate as continuous phase (in which cholesterol is soluble), a 4% final concentration of 0.05 mol L(-1) phosphate buffer solution, pH 7.4, as dispersed phase, and 0.1 mol L(-1) AOT as emulsifying agent. Studies on the repeatability of the amperometric response obtained at +0.10 V, with and without regeneration of the electrode surface by polishing, on the useful lifetime of one single biosensor and on the reproducibility in the fabrication of different pellets illustrate the robustness of the biosensor design. Determination of free and total cholesterol in food samples such as butter, lard, and egg yoke was carried out, and the obtained results were advantageously compared with those provided by using a commercial Boehringer test kit.
Collapse
|
220
|
Gálvez R, Pedrero M, Buyo F, Manuel de Villena FJ, Pingarrón JM. Oil-in-water emulsions as suitable working media for the direct polarographic determination of aziprotryne and desmetryne from its organic extracts in water samples. FRESENIUS' JOURNAL OF ANALYTICAL CHEMISTRY 2000; 367:454-60. [PMID: 11227476 DOI: 10.1007/s002160000352] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/16/2023]
Abstract
The electroanalytical behavior of the reduction of the herbicides aziprotryne (2-azido-4-isopropylamino-6-methylthio-1,3,5-triazine) and desmetryne (4-isopropylamino-6-methylamino-2-methylthio-1,3,5-triazine) in oil-in-water emulsions is reported. This medium allows the differential pulse polarographic determination of these s-triazines directly from their sample extracts in an appropriate organic solvent. Sodium pentanesulfonate was chosen as the most suitable surfactant to be used as emulsifying agent, whereas ethyl acetate was selected as the organic solvent to form the emulsions. The peak current was maximum in a 0.3 mol L(-1) HClO4 medium of the continuous aqueous phase for aziprotryne, and at pH 3.0 for desmetryne, and the potential became more negative as the pH increased for both herbicides. The limiting current is diffusion controlled and the electrode process is irreversible. Four electrons are involved in the overall electrochemical reduction process as determined by controlled potential coulometry, whereas the alpha n(a) values suggested that two electrons are involved in the rate-determining step. Using differential pulse polarography, aziprotryne and desmetryne can be determined in the emulsified medium over the concentration ranges 1.0 x 10(-7)-1.0 x 10(-4) mol L(-1), with limits of detection of 4.5 x 10(-8) mol L(-1) and 6.6 x 10(-8) mol L(-1), respectively. The method was applied to the determination of aziprotryne and desmetryne in spiked irrigation water. At concentration levels of 6.0 x 10(-7) mol L(-1) aziprotryne and 4.0 x 10(-7) mol L(-1) desmetryne, recoveries of 94 +/- 3% and 94 +/- 4%, respectively, were obtained after preconcentration on Sep-Pack C18 cartridges. Finally, partial least-squares regression (PLSR) has been used for treatment of the polarographic data obtained from mixtures of aziprotryne, desmetryne and simazine in oil-in-water emulsions. The size of the calibration set was of 29 samples by ninety two current measurements at different potentials. Prediction of the herbicides concentration within the range 1.0 x 10(-6)-1.0 x 10(-5) mol L(-1) was possible.
Collapse
|
221
|
Pérez-Alonso FJ, Agüí L, Yáñez-Sedeño P, Pingarrón JM. Determination of styrene and styrene additives using cylindrical microelectrodes in acetone. Analyst 2000. [DOI: 10.1039/b005634k] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
222
|
Serra B, Reviejo AJ, Parrado C, Pingarrón JM. Graphite-Teflon composite bienzyme electrodes for the determination of L-lactate: application to food samples. Biosens Bioelectron 1999; 14:505-13. [PMID: 10451918 DOI: 10.1016/s0956-5663(99)00022-6] [Citation(s) in RCA: 53] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
A bienzyme amperometric graphite-Teflon composite biosensor, in which lactate oxidase (LOD) and peroxidase, together with the mediator ferrocene, are incorporated into the electrode matrix, was developed for the determination of L-lactate in food samples such as wine and yogurt by using both batch- and flow-injection modes. This bienzyme electrode was fabricated by simple physical inclusion of the enzymes and the mediator in the bulk of the graphite-Teflon matrix. A Teflon content of 70%, an applied potential of 0.00 V, and a pH of 7.4 were employed as working conditions. The composite bioelectrode exhibited long-term operation because of the renewability of its surface by polishing. Reproducible amperometric responses were achieved with different electrodes fabricated from different composite matrices, and no significant loss of the enzyme activity occurred after 6 months of storage at 4 degrees C. Detection limits for L-lactate of 1.4 and 0.9 microM were obtained by batch amperometry in stirred solutions and flow-injection with amperometric detection, respectively. An interferences study with different substances which may be present in wine and yogurt together with L-lactic acid demonstrated very good selectivity for the determination of this analyte. The bienzyme composite electrode was applied to the determination of L-lactic acid in red wine and shaken yogurt, and the methods were validated by comparing these results with those obtained by applying a recommended reference method.
Collapse
|
223
|
Alonso L, Parrado C, Pedrero M, Agüí L, Pingarrón JM. Graphite-Ethylene/Propylene/Diene Terpolymer Composite Electrodes. A New Electrode Material for Electrochemical Detection. ELECTROANAL 1999. [DOI: 10.1002/(sici)1521-4109(199903)11:3<161::aid-elan161>3.0.co;2-3] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
224
|
Diego E, Agüí L, González-Cortés A, Yáñez-Sedeño P, Pingarrón JM, Kauffmann JM. Critical Comparison of Paraffin Carbon Paste and Graphite-Poly(tetrafluorethylene) Composite Electrodes Concerning the Electroanalytical Behavior of Various Antioxidants of Different Hydrophobicity. ELECTROANAL 1998. [DOI: 10.1002/(sici)1521-4109(199801)10:1<33::aid-elan33>3.0.co;2-w] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
225
|
Ortiz G, González MC, Reviejo AJ, Pingarrón JM. Graphite−Poly(tetrafluoroethylene) Composite Enzyme Electrodes as Suitable Biosensors in Predominantly Nonaqueous Media. Anal Chem 1997; 69:3521-6. [DOI: 10.1021/ac970172n] [Citation(s) in RCA: 23] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|