1
|
Manmana Y, Liu C, Koino H, Sueyoshi K, Kitagawa F, Kubo T, Otsuka K. Development of transient trapping micellar electrokinetic chromatography coupled with mass spectrometry for steroids analysis. Chirality 2022; 34:1328-1337. [PMID: 35754139 DOI: 10.1002/chir.23489] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2021] [Revised: 04/06/2022] [Accepted: 05/23/2022] [Indexed: 11/05/2022]
Abstract
An on-line sample preconcentration technique based on transient trapping (tr-trapping) in micellar electrokinetic chromatography (MEKC) was applied for steroid detection with UV (tr-trapping-UV) and electrospray ionization mass spectrometry detection (tr-trapping-ESI-MS). ESI-MS was used to improve the sensitivity in MEKC. The MEKC separation was carried out using volatile ammonium formate as a background solution to facilitate the coupling with ESI-MS. The partial introduction of a sodium dodecyl sulfate (SDS) micellar solution before the introduction of a sample solution to the capillary provided the effective preconcentration of analytes. At the same time, the SDS micelle would not enter the ESI-MS system, so its interference in ESI-MS detection was suppressed under the optimal condition, then five steroids can be separated by the developed method. In tr-trapping-ESI-MS, an acidic condition of pH 3.5 was employed to suppress the electroosmotic flow, which can avoid micellar solution migrating to the MS instrument. The developed method showed that the micellar solution requires a twofold slower time than the sample to migrate along the column, which can prohibit the cause of the problem with the MS instrument and interference signal of SDS in the steroid's detection. The tr-trapping-ESI-MS protocol showed up to 540-fold enhancements of the peak intensity and 50-fold improvement of the limit of detection compared with capillary zone electrophoresis using androsterone as a model sample.
Collapse
Affiliation(s)
- Yanawut Manmana
- Graduate School of Engineering, Kyoto University, Kyoto, Japan
| | - Chenchen Liu
- Graduate School of Engineering, Kyoto University, Kyoto, Japan
| | - Hiroshi Koino
- Graduate School of Engineering, Kyoto University, Kyoto, Japan
| | - Kenji Sueyoshi
- Graduate School of Engineering, Osaka Prefecture University, Osaka, Japan
| | - Fumihiko Kitagawa
- Graduate School of Science and Technology, Hirosaki University, Aomori, Japan
| | - Takuya Kubo
- Graduate School of Engineering, Kyoto University, Kyoto, Japan
| | - Koji Otsuka
- Graduate School of Engineering, Kyoto University, Kyoto, Japan
| |
Collapse
|
2
|
Capillary electrochromatography-mass spectrometry of kynurenine pathway metabolites. J Chromatogr A 2021; 1651:462294. [PMID: 34098249 DOI: 10.1016/j.chroma.2021.462294] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2021] [Revised: 05/19/2021] [Accepted: 05/24/2021] [Indexed: 01/13/2023]
Abstract
Few articles are reported for the simultaneous separation and sensitive detection of the kynurenine pathway (KP) metabolites. This work describes a capillary electrochromatography-mass spectrometry (CEC-MS) method using acrylamido-2-methyl-1-propanesulfonic acid (AMPS) functionalized stationary phase. The AMPS column was prepared by first performing silanization of bare silica with gamma-maps, followed by polymerization with AMPS. The CEC-MS/MS methods were established for six upstream and three downstream KP metabolites. The simultaneous separation of all nine KP metabolites is achieved without derivatization for the first time in the open literature. Numerous parameters such as pH and the concentration of background electrolyte, the concentration of the polymerizable AMPS monomer, column length, field strength, and internal pressure were all tested to optimize the separation of multiple KP metabolites. A baseline separation of six upstream metabolites, namely tryptophan (TRP), kynurenine (KYN), 3-hydroxykynurenine (HKYN), kynurenic acid (KA), anthranilic acid (AA), and xanthurenic acid (XA), was possible at pH 9.25 within 26 min. Separation of six downstream and related metabolites, namely: tryptamine (TRPM), hydroxy‑tryptophan (HTRP), hydroxyindole-3 acetic acid (HIAA), 3-hydroxyanthranilic acid (3-HAA), picolinic acid (PA), and quinolinic acid (QA), was achieved at pH 9.75 in 30 min. However, the challenging simultaneous separation of all nine KP metabolites was only accomplished by increasing the column length and simultaneous application of internal pressure and voltage in 114 min. Quantitation of KP metabolites in commercial human plasma was carried out, and endogenous concentration of five KP metabolites was validated. The experimental limit of quantitation ranges from 100 to 10,000 nM (S/N = 8-832, respectively), whereas the experimental limit of detection ranges from 31 to 1000 nM (S/N = 2-16, respectively). Levels of five major KP metabolites, namely TRP, KYN, KA, AA, and QA, and their ratios in patient plasma samples previously screened for inflammatory biomarkers [C-reactive protein (CRP) and tumor necrosis factor-alpha (TNF-α)] was measured. Pairs of the level of metabolites with significant positive correlation were statistically evaluated.
Collapse
|
3
|
Ortiz-Villanueva E, Jaumot J, Benavente F, Piña B, Sanz-Nebot V, Tauler R. Combination of CE-MS and advancedchemometricmethods for high-throughput metabolic profiling. Electrophoresis 2015; 36:2324-2335. [DOI: 10.1002/elps.201500027] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2015] [Revised: 03/16/2015] [Accepted: 03/20/2015] [Indexed: 12/22/2022]
Affiliation(s)
| | - Joaquim Jaumot
- Department of Environmental Chemistry; IDAEA-CSIC; Barcelona Spain
| | - Fernando Benavente
- Department of Analytical Chemistry; University of Barcelona; Barcelona Spain
| | - Benjamín Piña
- Department of Environmental Chemistry; IDAEA-CSIC; Barcelona Spain
| | - Victoria Sanz-Nebot
- Department of Analytical Chemistry; University of Barcelona; Barcelona Spain
| | - Romà Tauler
- Department of Environmental Chemistry; IDAEA-CSIC; Barcelona Spain
| |
Collapse
|
4
|
Moini M, Rollman CM. Compatibility of highly sulfated cyclodextrin with electrospray ionization at low nanoliter/minute flow rates and its application to capillary electrophoresis/electrospray ionization mass spectrometric analysis of cathinone derivatives and their optical isomers. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2015; 29:304-10. [PMID: 26411628 DOI: 10.1002/rcm.7106] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/10/2014] [Revised: 11/13/2014] [Accepted: 11/24/2014] [Indexed: 05/14/2023]
Abstract
RATIONALE Sodium salts of cyclodextrins are commonly used in capillary electrophoresis/mass spectrometry (CE/MS) analysis of illicit drugs and their optical isomers. To avoid the suppression effect of cyclodextrins under electrospray ionization (ESI), the partial filling technique (PFT) is commonly utilized, which has a limited resolution. Low-flow nano-ESI has been shown to reduce the suppression effect of the salts. To test the compatibility of low-flow ESI with a background electrolyte (BGE) containing sodium salts of cyclodextrin, sheathless narrow capillary CE/MS with flow rates of low nanoliters/minute (nL/min) was applied to the separation and detection of cathinones and their positional and optical isomers for the first time. METHODS Low-flow sheathless CE/MS using a 20-µm-i.d. capillary in conjunction with a porous tip interface was used for the separation of cathinone derivatives and their optical isomers. Highly sulfated γ-cyclodextrin (HS-γ-CD) in conjunction with (+)-18-crown-6-tetracarboxylic acid ((+)-18-C-6-TCA) was used as the BGE and an ion trap mass spectrometer operating in full scan mode was utilized. RESULTS Utilizing low flow rate (~10 nL/min) sheathless CE/MS, the use of the sodium salt of HS-γ-CD as the BGE was compared with the same solution using PFT. The relative and absolute sensitivity of detection of cathinones were about the same, indicating that under low-flow sheathless CE/MS there was no significant suppression due to the existence of HS-γ-CD in the electrospray process. However, enhanced resolution of cathinone derivatives and their positional and optical isomers was observed when the solution of HS-γ-CD was used as the BGE. The enhanced resolution was because of the presence of the HS-γ-CD in the entire capillary during the analysis. The addition of 15 mM (+)-18-C-6-TCA to the BGE containing HS-γ-CD further enhanced the resolution resulting in separation of all cathinones and their positional and optical isomers. CONCLUSIONS A novel CE/MS technique has been introduced that combines low-flow sheathless CE/MS, with HS-γ-CD and 15 mM (+)-18-C-6-TCA as the BGE for separation of cathinone derivatives as well as their positional and optical isomers.
Collapse
Affiliation(s)
- Mehdi Moini
- Department of Forensic Sciences, George Washington University, Washington, DC, USA
| | | |
Collapse
|
5
|
Wang X, Davis I, Liu A, Shamsi SA. Development of a CZE-ESI-MS assay with a sulfonated capillary for profiling picolinic acid and quinolinic acid formation in multienzyme system. Electrophoresis 2013; 34:1828-35. [PMID: 23576119 PMCID: PMC4153595 DOI: 10.1002/elps.201200679] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2012] [Revised: 01/26/2013] [Accepted: 01/27/2013] [Indexed: 11/08/2022]
Abstract
This article describes the development of a reliable CZE-ESI-MS method to simultaneously separate and quantitate three specific metabolites (3-hydroxyanthranilic acid (3-HAA), quinolinic acid (QA), and picolinic acid (PA)) of the kynurenine pathway (KP) of tryptophan catabolism. Using a covalently bonded sulfonated capillary, the parameters such as pH, type of background electrolyte, type of organic solvent, nebulizer pressure as well as both negative and positive ESI-MS modes were optimized to achieve the best Rs and S/N of three KP metabolites. The developed CZE-ESI-MS assay provided high resolution of PA/QA, high specificity, a total analysis time of 10 min with satisfactory intraday and interday repeatability of migration time and peak areas. Under optimized CZE-ESI-MS conditions, the calibration curves over a concentration range of 19-300 μM for 3-HAA and QA, and 75-300 μM for PA were simultaneously generated. The method was successfully applied for the first time to profile the concentrations of initial substrate, 3-HAA, and its eventual products, PA and QA, formed in the complex multienzyme system. As the ratio of two enzymes, 3-hydroxyanthranilate 3,4-dioxygenase (HAO) and α-amino-β-carboxymuconate-ε-semialdehyde decarboxylase (ACMSD) decreases, the concentration of QA approaches essentially zero indicating that all ACMS formed by the action of HAO is consumed by ACMSD rather than its spontaneous decay to QA.
Collapse
Affiliation(s)
- Xiaochun Wang
- Department of Chemistry, Center of Diagnostics and Therapeutics, Georgia State University, 50 Decatur Street, Atlanta, GA 30303, USA
| | - Ian Davis
- Department of Chemistry, Center of Diagnostics and Therapeutics, Georgia State University, 50 Decatur Street, Atlanta, GA 30303, USA
| | - Aimin Liu
- Department of Chemistry, Center of Diagnostics and Therapeutics, Georgia State University, 50 Decatur Street, Atlanta, GA 30303, USA
| | - Shahab A. Shamsi
- Department of Chemistry, Center of Diagnostics and Therapeutics, Georgia State University, 50 Decatur Street, Atlanta, GA 30303, USA
| |
Collapse
|
6
|
Bonvin G, Veuthey JL, Rudaz S, Schappler J. Evaluation of a sheathless nanospray interface based on a porous tip sprayer for CE-ESI-MS coupling. Electrophoresis 2012; 33:552-62. [DOI: 10.1002/elps.201100461] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
7
|
Stanley B, Lucy CA. Micellar electrokinetic chromatography with acid labile surfactant. J Chromatogr A 2012; 1226:55-60. [DOI: 10.1016/j.chroma.2011.09.065] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2011] [Revised: 09/23/2011] [Accepted: 09/23/2011] [Indexed: 01/12/2023]
|
8
|
Bragg W, Shamsi SA. Development of a fritless packed column for capillary electrochromatography-mass spectrometry. J Chromatogr A 2011; 1218:8691-700. [PMID: 22035695 DOI: 10.1016/j.chroma.2011.09.060] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2011] [Revised: 09/23/2011] [Accepted: 09/23/2011] [Indexed: 11/25/2022]
Abstract
A novel procedure was developed for the fabrication of a fritless packed column for the coupling of capillary electrochromatography (CEC) to mass spectrometry (MS). The process involved the formation of internal tapers on two separate columns. Once the internal tapers are formed and the columns are packed, the untapered ends of each column were joined together by a commercially available connector. Several advantages of the fritless columns are described. First, the design used here eventually eliminates the need for any frits thus reducing the possibility of bubble formation seen with fritted packed columns. In addition, this is the first report in which the internal tapers are formed at both the inlet and outlet column ends making the fritless CEC-MS column more robust compared to only one report with externally tapered counterparts. Second, a comparison of internally tapered single frit packed CEC-MS (previously developed in our laboratory) column versus fritless CEC-MS column reported here shows that the latter provides better efficiency, suggesting no dead volume with equally good sensitivity and chiral resolution of (±)-aminoglutethimide. The fritless column procedure is universal and was used to prepare a series of columns with a variety of commercially available packing material (mixed mode strong cation exchange, SCX; mixed mode strong anion exchange, SAX; C-18) for the separation and MS detection of short chain non-chromophoric polar amines, long chain nonchromophic anionic surfactant as well as oligomers of non-chromophoric non-ionic surfactants, respectively. The fritless columns showed good intra-day repeatability and inter-day reproducibility of retention times, chiral and achiral resolutions and peak areas. Very satisfactory column-to-column and operator-to-operator reproducibility was demonstrated.
Collapse
Affiliation(s)
- William Bragg
- Department of Chemistry, Center for Biotechnology and Drug Design, Georgia State University, Atlanta, GA 30302, USA
| | | |
Collapse
|
9
|
Han Y, Bai Y, Xiao Y, Du F, Liang Y, Tan Z, Zhao M, Liu H. Simultaneous discrimination of jasmonic acid stereoisomers by CE-QTOF-MS employing the partial filling technique. Electrophoresis 2011; 32:2693-9. [PMID: 21910130 DOI: 10.1002/elps.201100043] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2011] [Revised: 03/22/2011] [Accepted: 03/31/2011] [Indexed: 11/10/2022]
Abstract
Jasmonic acid (JA), an essential plant hormone controlling the plant defense signaling system and developmental processes, has stereospecific bioactivities that have not been well understood mainly due to the limitation in separation and detection methodologies. In this work, a fast CE-UV method based on short-end injection technique and a sensitive CE-QTOF-MS method based on partial filling technique were successfully developed for the enantioseparation of racemic JA. The successive coating technique was also involved by modifying the capillary with multiple ionic polymer layers of polybrene-dextran sulfate-polybrene. This was the first report on the direct resolution of both pairs of JA enantiomers, including two naturally occurring JA stereoisomers. Although no pure JA stereoisomers were commercially available, all the separated JA stereoisomers were identified indirectly by comparing the difference between the racemic standard and plant samples based on the presence and the ratio of each stereoisomer. Satisfactory results were obtained in terms of sensitivity (LOD, 24 ng/mL or 0.7 fmol for single JA stereoisomer) using 45 mmol/L ammonium acetate at pH 4.5 containing 70 mmol/L α-CD as the buffer system. This established CE-QTOF-MS method was later successfully applied for the study of the naturally occurring JA stereoisomers in wounded tobacco leaves.
Collapse
Affiliation(s)
- Yehua Han
- Beijing National Laboratory for Molecular Sciences, Institute of Analytical Chemistry, College of Chemistry and Molecular Engineering, Peking University, Beijing, P. R. China
| | | | | | | | | | | | | | | |
Collapse
|
10
|
Aturki Z, D'Orazio G, Rocco A, Fanali S. Advances in the enantioseparation of β-blocker drugs by capillary electromigration techniques. Electrophoresis 2011; 32:2602-28. [PMID: 21905049 DOI: 10.1002/elps.201100153] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2011] [Revised: 04/08/2011] [Accepted: 04/09/2011] [Indexed: 11/07/2022]
Abstract
β-Blocker drugs or β-adrenergic blocking agents are an important class of drugs, prescribed with great frequency. They are used for various diseases, particularly for the treatment of cardiac arrhythmias, cardioprotection after myocardial infarction (heart attack), and hypertension. Almost all β-blocker drugs possess one or more stereogenic centers; however; only some of them are administered as single enantiomers. Since both enantiomers can differ in their pharmacological and toxicological properties, enantioselective analytical methods are required not only for pharmacodynamic and pharmacokinetic studies but also for quality control of pharmaceutical preparations with the determination of enantiomeric purity. In addition to the chromatographic tools, in recent years, capillary electromigration techniques (CE, CEC, and MEKC) have been widely used for enantioselective purposes employing a variety of chiral selectors, e.g. CDs, polysaccharides, macrocyclic antibiotics, proteins, chiral ion-paring agents, etc. The high separation efficiency, rapid analysi,s and low consumption of reagents of electromigration methods make them a very attractive alternative to the conventional chromatographic methods. In this review, the development and applications of electrodriven methods for the enantioseparation of β-blocker drugs are reported. The papers concerning this topic, published from January 2000 until December 2010, are summarised here. Particular attention is given to the coupling of chiral CE and CEC methods to MS, as this detector provides high sensitivity and selectivity.
Collapse
Affiliation(s)
- Zeineb Aturki
- Istituto di Metodologie Chimiche, Consiglio Nazionale delle Ricerche, Area della Ricerca di Roma, Monterotondo Scalo, Rome, Italy
| | | | | | | |
Collapse
|
11
|
Marák J, Staňová A, Gajdoštínová S, Škultéty L, Kaniansky D. Some possibilities of an analysis of complex samples by a mass spectrometry with a sample pretreatment by an offline coupled preparative capillary isotachophoresis. Electrophoresis 2011; 32:1273-81. [DOI: 10.1002/elps.201000629] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2010] [Revised: 01/10/2011] [Accepted: 01/20/2011] [Indexed: 01/30/2023]
|
12
|
Jecklin MC, Schmid S, Urban PL, Amantonico A, Zenobi R. Miniature flowing atmospheric-pressure afterglow ion source for facile interfacing of CE with MS. Electrophoresis 2010; 31:3597-605. [DOI: 10.1002/elps.201000350] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
13
|
Abstract
This review article addresses the developments and applications of capillary electromigration methods coupled on-line with MS for chiral analysis. The multiple enantiomeric applications of this hyphenated technology are covered including chiral analysis of drugs, food compounds, pesticides, natural metabolites, etc. in different matrices such as plasma, urine, medicines, foods, etc. This work intends to provide an updated overview (including works published till September 2009) on the principal chiral applications carried out by CZE-MS, CEC-MS and MEKC-MS, discussing their main advantages and drawbacks in all their different areas of application as well as their foreseeable development in the not too distant future.
Collapse
Affiliation(s)
- Carolina Simó
- Department of Food Analysis, Institute of Industrial Fermentations (CSIC), Madrid, Spain
| | | | | |
Collapse
|
14
|
Herrero M, Simó C, García-Cañas V, Fanali S, Cifuentes A. Chiral capillary electrophoresis in food analysis. Electrophoresis 2010; 31:2106-14. [DOI: 10.1002/elps.200900770] [Citation(s) in RCA: 57] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
15
|
Recent advances of capillary electrophoresis in pharmaceutical analysis. Anal Bioanal Chem 2010; 398:29-52. [DOI: 10.1007/s00216-010-3741-5] [Citation(s) in RCA: 105] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2010] [Revised: 04/08/2010] [Accepted: 04/09/2010] [Indexed: 01/16/2023]
|
16
|
Ravelo-Pérez LM, Asensio-Ramos M, Hernández-Borges J, Rodríguez-Delgado MA. Recent food safety and food quality applications of CE-MS. Electrophoresis 2009; 30:1624-46. [PMID: 19360778 DOI: 10.1002/elps.200800670] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
The first on-line coupling of CE with MS detection more than 20 years ago provided a very powerful technique with a wide variety of applications, among which food analysis is of special interest, especially that dealing with food safety and food quality applications, the major topics of public interest nowadays. With this review article, we would like to show the most recent applications of CE-MS in both fields by recompiling and commenting articles published between January 2004 and October 2008. Although both applications are difficult to separate from each other, we have included in this work two main sections dealing with each specific field. Future trends will also be discussed.
Collapse
Affiliation(s)
- Lidia M Ravelo-Pérez
- Departamento de Química Analítica, Nutrición y Bromatología, Universidad de La Laguna, La Laguna, Tenerife, Islas Canarias, Spain
| | | | | | | |
Collapse
|
17
|
Huhn C, Ramautar R, Wuhrer M, Somsen GW. Relevance and use of capillary coatings in capillary electrophoresis–mass spectrometry. Anal Bioanal Chem 2009; 396:297-314. [DOI: 10.1007/s00216-009-3193-y] [Citation(s) in RCA: 154] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2009] [Revised: 09/22/2009] [Accepted: 09/24/2009] [Indexed: 11/24/2022]
|
18
|
He J, Shamsi SA. Multivariate approach for the enantioselective analysis in MEKC-MS: II. Optimization of 1,1'-binaphthyl-2,2'-diamine in positive ion mode. J Sep Sci 2009; 32:1916-26. [PMID: 19479771 DOI: 10.1002/jssc.200800711] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Enantiomeric separation and detection of 1,1'-binaphthyl-2,2'-diamine (BNA) has been successfully optimized by MEKC-ESI-MS using a polymeric surfactant polysodium N-undecenoxycarbonyl-L-leucinate (poly-L-SUCL) as a pseudostationary phase. In the first step, MEKC conditions were optimized by a five-factor three-level central composite design (CCD) of experiment. All five MEKC factors (buffer pH, percentage of ACN in the running buffer, concentration of surfactant, concentration of ammonium acetate (NH4OAc), and voltage) were found significant to the responses (measured as the chiral resolution and analysis time). The interactions between MEKC factors were further evaluated using a quadratic model equation which allowed the generation of 3-D response surface image to reach the optimum conditions. To obtain the best S/N, sheath liquid composition and spray chamber parameters were successfully optimized using the same strategy. Baseline enantiomeric resolution in less than 20 min and optimum MS signal of BNA enantiomers (S/N = 45 at 0.4 mg/mL) were ultimately achieved at the optimized conditions. The adequacy of the model was validated by experimental runs at the optimal predicted conditions. The predicted results were found to be in good agreement with the experimental data.
Collapse
Affiliation(s)
- Jun He
- Department of Chemistry, Center of Biotechnology and Drug Design, Georgia State University, Atlanta, GA 30303, USA
| | | |
Collapse
|
19
|
Tseng WL, Hsu CY, Wu TH, Huang SW, Hsieh MM. Highly sensitive detection of chiral amino acids by CE based on on-line stacking techniques. Electrophoresis 2009; 30:2558-64. [DOI: 10.1002/elps.200800765] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
20
|
Mokaddem M, Gareil P, Belgaied JE, Varenne A. New insight into suction and dilution effects in CE coupled to MSviaan ESI interface. II - Dilution effect. Electrophoresis 2009; 30:1692-7. [DOI: 10.1002/elps.200800480] [Citation(s) in RCA: 41] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
21
|
Giuffrida A, León C, García-Cañas V, Cucinotta V, Cifuentes A. Modified cyclodextrins for fast and sensitive chiral-capillary electrophoresis-mass spectrometry. Electrophoresis 2009; 30:1734-42. [DOI: 10.1002/elps.200800333] [Citation(s) in RCA: 66] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
22
|
Bragg W, Norton D, Shamsi SA. Optimized separation of beta-blockers with multiple chiral centers using capillary electrochromatography-mass spectrometry. J Chromatogr B Analyt Technol Biomed Life Sci 2009; 875:304-16. [PMID: 18619928 DOI: 10.1016/j.jchromb.2008.06.028] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2008] [Revised: 06/06/2008] [Accepted: 06/17/2008] [Indexed: 10/21/2022]
Abstract
This work focuses on the simultaneous analysis of beta-blockers with multiple stereogenic centers using capillary electrochromatography-mass spectrometry (CEC-MS) with a vancomycin stationary phase. The critical mobile phase variables (composition of organic solvents, acid/base ratios) as well as column temperature and electric field strength, effecting enantioresolution and analysis time were first optimized sequentially. Next, to achieve global optimum a multivariate D-optimal design was used. Although multivariate approach did not improve enantioresolution any further, analysis time was significantly reduced. Under optimum CEC-MS conditions, all stereoisomers were resolved with resolution in the range 1.0-3.1 in less than 60 min with an average signal-to-noise (S/N) greater than 1000. The developed CEC-MS method has the potential to emerge as a screening method for analysis of multiple chiral compounds using a single protocol using the same column and mobile phase conditions, thus reducing the operation time and cost.
Collapse
Affiliation(s)
- William Bragg
- Department of Chemistry, Center of Biotechnology and Drug Design, Georgia State University, Atlanta, GA 30303, USA
| | | | | |
Collapse
|
23
|
Pantůčková P, Gebauer P, Boček P, Křivánková L. Electrolyte systems for on-line CE-MS: Detection requirements and separation possibilities. Electrophoresis 2009; 30:203-14. [DOI: 10.1002/elps.200800262] [Citation(s) in RCA: 53] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
24
|
Norton D, Shamsi SA. Packed-column capillary electrochromatography and capillary electrochromatography-mass spectrometry using a lithocholic acid stationary phase. Electrophoresis 2008; 29:2004-15. [PMID: 18425746 DOI: 10.1002/elps.200700460] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
The preparation and characterization of a novel lithocholic acid (LCA)-based liquid crystalline (LC) stationary phase (SP) suitable for application in packed-column CEC and CEC coupled to MS is described. The extent of bonding reactions of LCA-SP was assessed using 1H-NMR, 13C-NMR and elemental analysis. This characterization is followed by application of the LCA-SP for separation of beta-blockers, phenylethylamines (PEAs), polyaromatic hydrocarbons (PAHs) and polychlorinated biphenyls (PCBs). Using the optimum mobile phase operating conditions (pH 3.0-4.5, 10 mM ammonium acetate, 85% v/v ACN), a comparison of the chromatographic ability of the aminopropyl silica phase vs. the LCA-bonded phase was conducted. The results showed improved selectivity for all test analytes using the latter phase. For example, the CEC-MS of beta-blockers demonstrated that the LCA-bonded phase provides separation of six out of seven beta-blockers, whereas the amino silica phase provides four peaks of several co-eluting beta-blockers. For the CEC-MS analysis of PEAs, the LCA-bonded phase showed improved resolution and different selectivity as compared to the aminopropyl phase. An evaluation of the retention trends for PEAs on both phases suggested that the PEAs were retained based on varying degree of hydroxyl substitution on the aromatic ring. In addition, the MS characterization shows several PEAs fragment in the electrospray either by loss of an alkyl group and/or by loss of H2O. Finally, the LCA-bonded phase displayed significantly higher separation selectivity for PAHs and PCBs as compared to the amino silica phase.
Collapse
|
25
|
Mokaddem M, Gareil P, Belgaied JE, Varenne A. A new insight into suction and dilution effects in capillary electrophoresis coupled to mass spectrometry via an electrospray ionization interface. Part I-Suction effect. Electrophoresis 2008; 29:1957-64. [PMID: 18425757 DOI: 10.1002/elps.200700880] [Citation(s) in RCA: 55] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
The hyphenation of CE with MS is nowadays accepted as a powerful analytical approach. Employing ESI, the most common interface, one challenge is to provide quantitative information, which is quite a difficult task, as it is linked, among other factors, to suction and dilution effects. In the coaxial ESI configuration, the suction effect has been presented in literature as stemming from nebulizing gas (NG) flow rate and drying gas temperature. But as this interface consists in three concentric capillaries, allowing for BGE, sheath liquid (SL) and NG mixing, it is demonstrated herein that other parameters are also involved in this suction effect: the CE capillary protrusion from the interface needle, SL flow rate, and overall BGE flow rate and velocity profile. Whereas NG flow rate is the parameter affecting suction to a greater extent, separation capillary protruding length, SL, and overall BGE flow rate have a significant additional impact on this phenomenon. It is shown that SL flow rate can affect suction differently according to the NG velocity, which may be explained by modification of the Taylor cone geometry. Furthermore, it appears that suction effect is noticeably favored by a parabolic velocity profile of the BGE, again probably due to the Taylor cone shape modification. Finally, the temperature gradient created by the contact between the heated NG and the separation capillary enhances this effect.
Collapse
Affiliation(s)
- Meriem Mokaddem
- Laboratoire d'Electrochimie et Chimie Analytique, UMR7575 CNRS-ENSCP-Paris6 Paris, France
| | | | | | | |
Collapse
|
26
|
Scriba GKEV. Cyclodextrins in capillary electrophoresis enantioseparations--recent developments and applications. J Sep Sci 2008; 31:1991-2011. [PMID: 18491357 DOI: 10.1002/jssc.200800095] [Citation(s) in RCA: 140] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Capillary EKC has been established as a versatile and robust CE method for the separation of enantiomers. Within the chiral selectors added to the BGE CDs continue as the most widely used selectors due to their structural variety and commercial availability. This is reflected in the large number of practical applications of CDs to analytical enantioseparations that have been reported between January 2006 and January 2008, the period of time covered by this review. Most of these applications cover aspects of life sciences such as drug analysis, bioanalysis, environmental analysis, or food analysis. Moreover, new CD derivatives have been developed in an attempt to achieve altered enantioselectivities and to further broaden the application range. Finally, efforts will be summarized that aim at an understanding of the molecular level of the chiral recognition between CDs and the analytes.
Collapse
Affiliation(s)
- Gerhard K E V Scriba
- Department of Pharmaceutical Chemistry, School of Pharmacy, Friedrich Schiller University, Philosophenweg 14, D-07743 Jena, Germany.
| |
Collapse
|
27
|
Chiral separation by capillary electromigration techniques. J Chromatogr A 2008; 1204:140-56. [DOI: 10.1016/j.chroma.2008.07.071] [Citation(s) in RCA: 208] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2008] [Revised: 06/27/2008] [Accepted: 07/08/2008] [Indexed: 11/19/2022]
|
28
|
Herrero M, Ibañez E, Cifuentes A. Capillary electrophoresis-electrospray-mass spectrometry in peptide analysis and peptidomics. Electrophoresis 2008; 29:2148-60. [DOI: 10.1002/elps.200700404] [Citation(s) in RCA: 107] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
|
29
|
Amundsen LK, Kokkonen JT, Sirén H. Comparison of partial filling MEKC analyses of steroids with use of ESI-MS and UV spectrophotometry. J Sep Sci 2008; 31:803-13. [DOI: 10.1002/jssc.200700657] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
30
|
18 Coupling CE and microchip-based devices with mass spectrometry. ACTA ACUST UNITED AC 2008. [DOI: 10.1016/s0149-6395(07)00018-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register]
|
31
|
Mol R, de Jong GJ, Somsen GW. Coupling of non-aqueous electrokinetic chromatography using cationic cyclodextrins with electrospray ionization mass spectrometry. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2008; 22:790-796. [PMID: 18275093 DOI: 10.1002/rcm.3431] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
Non-aqueous electrokinetic chromatography (NAEKC) using cationic cyclodextrins (CDs) was coupled to electrospray ionization mass spectrometry (ESI-MS). A methanolic background electrolyte (BGE) was used which contained the hydrochloride salts of the single-isomer derivative cyclodextrins 6-monodeoxy-6-mono(2-hydroxy)propylamino-beta-cyclodextrin (IPA-beta-CD) or 6-monodeoxy-6-mono(3-hydroxy)propylamino-beta-cyclodextrin (PA-beta-CD). Applying a reversed capillary electrophoresis (CE) polarity (-30 kV), efficient separation of negatively charged compounds was achieved with plate numbers of up to 190,000. PA-beta-CD appeared to be the most suitable for the separation of various acidic drugs while also providing a high chiral selectivity. Analyte detection was achieved by ESI-MS in the negative-ion mode using a sheath-liquid interface. In order to prevent current drops caused by the cathodic electroosmotic flow, a pressure of 15 mbar was applied on the inlet vial during NAEKC/MS analysis. The effect of the cationic CDs on the MS signal intensities of acidic test drugs was thoroughly studied. When a voltage is applied across the CE capillary, the overall mobility of the cationic CDs is towards the inlet vial so that no CD molecules enter the ion source. The chloride counter ions of the CDs, which migrated towards the capillary outlet, were found to cause ionization suppression, although significant analyte signals could still be detected. Depending on the CD concentration in the BGE, limits of detection for acidic drugs were in the 50-400 ng/mL range in full-scan mode.
Collapse
Affiliation(s)
- Roelof Mol
- Biomedical Analysis, Utrecht University, P.O. Box 80082, NL-3508 TB Utrecht, The Netherlands
| | | | | |
Collapse
|
32
|
Gottardo R, Fanigliulo A, Bortolotti F, De Paoli G, Pascali JP, Tagliaro F. Broad-spectrum toxicological analysis of hair based on capillary zone electrophoresis–time-of-flight mass spectrometry. J Chromatogr A 2007; 1159:190-7. [PMID: 17586513 DOI: 10.1016/j.chroma.2007.05.099] [Citation(s) in RCA: 52] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2006] [Revised: 05/23/2007] [Accepted: 05/24/2007] [Indexed: 11/26/2022]
Abstract
The coupling of capillary electrophoresis-electrospray ionization and time-of-flight mass spectrometry, combining efficiency and speed of separation with high mass accuracy and fast scanning capability, was for the first time applied to the determination of drugs of abuse (amphetamine, methamphetamine, MDA, MDMA, ephedrine, cocaine, morphine, codeine) and their metabolites in hair (6-MAM, benzoylecgonine). Experimental conditions were as follows. Separation: voltage 15 kV, uncoated fused-silica capillary (75 microm ID, 100 cm total length), running electrolyte 25 mM ammonium formate, pH 9.5, field-amplified sample stacking injection. Forensic drugs could be identified by exact mass determination (mass accuracy typically < or = 5 ppm) and by match of the isotopic pattern. The method was fully validated, showing limit of detections (LODs) suitable for the determination of all the compounds below the cut-off usually adopted for hair analysis (0.1 ng/mg). Analytical precision in real matrices (tested at 0.1 and 1.0 ng/mg) was typically characterized by CV's < or = 24% in both intra-day and day-to-day experiments. Quantitative determination was also tested by using a single internal standard (folcodine). Results, although with a moderate accuracy, conceivably depending on the lack of deuterated internal standards, proved useful for diagnostic use of the results from hair analysis. A single liquid-liquid extraction procedure was applied for all analytes, allowing the detection of a broad spectrum of basic drugs and their major metabolites.
Collapse
Affiliation(s)
- Rossella Gottardo
- Department of Medicine and Public Health, Unit of Forensic Medicine, University of Verona, Verona, Italy
| | | | | | | | | | | |
Collapse
|
33
|
Olsson J, Marlin ND, Blomberg LG. Enantiomeric Separation of Omeperazole Enantiomers by Aqueous CE Using UV and MS Detection. Chromatographia 2007. [DOI: 10.1365/s10337-007-0317-4] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
34
|
Hou J, Zheng J, Shamsi SA. Separation and determination of warfarin enantiomers in human plasma using a novel polymeric surfactant for micellar electrokinetic chromatography-mass spectrometry. J Chromatogr A 2007; 1159:208-16. [PMID: 17499757 PMCID: PMC2748864 DOI: 10.1016/j.chroma.2007.04.037] [Citation(s) in RCA: 65] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2007] [Revised: 04/08/2007] [Accepted: 04/19/2007] [Indexed: 11/27/2022]
Abstract
Warfarin is a widely used oral anticoagulant which is mostly administrated as a racemic mixture containing equal amount of R- and S-enantiomers. The two enantiomers are shown to exhibit significant differences in pharmacokinetics and pharmacodynamics. In this study, a new chiral micellar electrokinetic chromatography-mass spectrometry (MEKC-MS) method has been developed using a polymeric chiral surfactant, polysodium N-undecenoyl-L,L-leucyl-valinate (poly-L,L-SULV), as a pseudostationary phase for the chiral separation of (+/-)-warfarin (WAR) and (+/-)-coumachlor (COU, internal standard). Under optimum MEKC-MS conditions, the enantio-separation of both (+/-)-WAR and (+/-)-COU was achieved within 23 min. Calibration curves were linear (R=0.995 for (R)-WAR and R=0.989 for (S)-WAR) over the concentration range 0.25-5.0 microg/mL. The MS detection was found to be superior over the commonly used UV detection in terms of selectivity and sensitivity with LOD as low as 0.1 microg/mL in human plasma. The method was successfully applied to determine WAR enantiomeric ratio in patients' plasma undergoing warfarin therapy.
Collapse
Affiliation(s)
| | | | - Shahab A. Shamsi
- Department of Chemistry, Center of Biotechnology and Drug Design, Georgia State University, Atlanta, GA, 30303, USA
- Corresponding Author: Professor Shahab A. Shamsi, Department of Chemistry, Center of Biotechnology and Drug Design, Georgia State University, Atlanta, GA, 30303, USA, Phone: 404-651-1297; Fax: 404-651-2751,
| |
Collapse
|
35
|
Benavente F, Sanz-Nebot V, Barbosa J, van der Heijden R, van der Greef J, Hankemeier T. CE-ESI-MS of biological anions in plastic capillaries at high pH. Electrophoresis 2007; 28:944-9. [PMID: 17300131 DOI: 10.1002/elps.200600461] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
In this study, the potential of poly(methylmethacrylate) (PMMA, Plexiglas) and polyether ether ketone (PEEK) tubing for CE-ESI-MS separations of anions at high pH values was examined. A set of model compounds of biological interest was used to investigate the main operational parameters for CE-ESI-MS, such as the sheath-flow interface design, the polarity of the ionization voltage, the use of ammonia-based separation electrolytes, and the sheath liquid composition. Optimum separations and detection sensitivities in negative ESI mode were obtained using a running electrolyte of 75 mM of ammonia at pH 11 and a sheath liquid of 60:40 v/v or 75:25 v/v isopropanol/water with 0.5% v/v of ammonia. At these experimental conditions, PMMA and PEEK capillaries show good hydrolytic stabilities and lower EOF values than fused-silica columns. Better separation resolutions were obtained with PMMA capillary, but this plastic rapidly swelled and bled because of its limited chemical resistance to the sheath liquid. PMMA columns equipped with a fused-silica tip were used for a safer exposure to the sheath liquid, but the inner surface of the fused-silica tips had limited stability at pH 11. On the other hand, good separations and reproducibility on migration times and peak areas were obtained using PEEK capillaries without capillary column deterioration.
Collapse
Affiliation(s)
- Fernando Benavente
- Department of Analytical Chemistry, University of Barcelona, Barcelona, Spain.
| | | | | | | | | | | |
Collapse
|
36
|
Benavente F, van der Heijden R, Tjaden UR, van der Greef J, Hankemeier T. Metabolite profiling of human urine by CE-ESI-MS using separation electrolytes at low pH. Electrophoresis 2007; 27:4570-84. [PMID: 17054083 DOI: 10.1002/elps.200600055] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
We investigated the potential of CE coupled to electrospray MS (CE-ESI-MS) in metabolite profiling of human urine without any sample prefractionation step. A heterogeneous mixture of biologically relevant compounds covering a broad range of physicochemical properties was used to optimize separation conditions in fused-silica capillaries. A running electrolyte containing 50 mM of acetic acid and 50 mM of formic acid at pH 2.5 was used for the CE separations. A sheath-flow electrospray interface was employed for CE-ESI-MS analysis. Sheath liquids containing 80:20 v/v methanol/water with 0.1% v/v of acetic acid or 60:40 v/v isopropanol/water with 0.5% v/v of ammonia were selected for optimum detection in positive and negative ESI modes, respectively. Reproducibility and sensitivity were studied, and strategies for identification of the separated urinary compounds are suggested. We report major advantages and disadvantages of CE-ESI-MS for metabolite profiling of human body fluids. This work may be regarded as a first step in the use of CE-ESI-MS for reliable differential analysis of body fluids from healthy and diseased individuals.
Collapse
Affiliation(s)
- Fernando Benavente
- Division of Analytical Biosciences, Leiden/Amsterdam Center for Drug Research, Center for Medical Systems Biology, Leiden, The Netherlands
| | | | | | | | | |
Collapse
|
37
|
Scriba GKE. Nonaqueous capillary electrophoresis-mass spectrometry. J Chromatogr A 2007; 1159:28-41. [PMID: 17316665 DOI: 10.1016/j.chroma.2007.02.005] [Citation(s) in RCA: 57] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2006] [Revised: 01/30/2007] [Accepted: 02/05/2007] [Indexed: 11/27/2022]
Abstract
Nonaqueous background electrolytes broaden the application of capillary electrophoresis displaying altered separation selectivity and interactions between analytes and buffer additives compared to aqueous background electrolytes. In addition, nonaqueous capillary electrophoresis (NACE) appears to be ideally suited for online coupling with mass spectrometry due to the high volatility and low surface tension of many organic solvents. Despite these advantages and an increasing use of nonaqueous background electrolytes in CE, coupling of NACE to mass spectrometry has not yet been applied very often to date. The present review summarizes the applications of online NACE-MS with regard to the analysis of drugs, stereoisomers, peptides, alkaloids, polymers and others. A brief discussion of solvent effects in NACE and pH of nonaqueous background electrolyte systems is also presented.
Collapse
Affiliation(s)
- Gerhard K E Scriba
- Friedrich-Schiller-University Jena, School of Pharmacy, Philosophenweg 14, 07743 Jena, Germany.
| |
Collapse
|
38
|
Zheng J, Rizvi SAA, Shamsi SA, Hou J. Photopolymerized Sol‐Gel Monolithic Column for Capillary Electrochromatography (CEC) and CEC Coupled to Atmospheric Pressure Photoionization Mass Spectrometry. J LIQ CHROMATOGR R T 2007. [DOI: 10.1080/10826070601034238] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Affiliation(s)
- Jie Zheng
- a Department of Chemistry , Center of Biotechnology and Drug Design, Georgia State University , Atlanta, Georgia, USA
| | - Syed A. A. Rizvi
- a Department of Chemistry , Center of Biotechnology and Drug Design, Georgia State University , Atlanta, Georgia, USA
| | - Shahab A. Shamsi
- a Department of Chemistry , Center of Biotechnology and Drug Design, Georgia State University , Atlanta, Georgia, USA
| | - Jingguo Hou
- b Department of Clinical Sciences and Administration , College of Pharmacy, University of Houston, Texas Medical Center , Houston, Texas, USA
| |
Collapse
|
39
|
Van Biesen G, Bottaro CS. Ammonium perfluorooctanoate as a volatile surfactant for the analysis ofN-methylcarbamates by MEKC-ESI-MS. Electrophoresis 2006; 27:4456-68. [PMID: 17058301 DOI: 10.1002/elps.200600076] [Citation(s) in RCA: 32] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Ammonium perfluorooctanoate (APFOA) was investigated as an MS-friendly surfactant for the analysis of a mixture of ten N-methylcarbamates with MEKC-ESI-MS. Because of the relatively low boiling point of perfluorooctanoic acid ( approximately 190 degrees C), APFOA can be introduced into a mass spectrometer without the adverse effects of less volatile surfactants such as SDS. With a BGE consisting of 50 mM APFOA/isopropanol (IPA) 98:2 and with 30 kV applied, a very fast separation ( approximately 6 min) was possible with only one pair of analytes comigrating. Using an experimental design with four factors (voltage, nebulizer pressure, concentration of APFOA, and concentration of IPA) we were able to resolve all analytes in just over 11 min. Sheath liquid composition and flow rate, drying gas temperature and flow rate, and fragmentor voltage were then optimized for maximum signal intensity and S/N. It was found that the faster method gave better S/N because of narrower peak widths, and detection limits in SIM mode were between 0.01 (aldicarb) and 0.08 mg/L (methomyl). Calibration curves were prepared with standards of 0.50, 1.00, and 2.00 mg/L for the analysis of samples obtained after SPE of tap water spiked with the ten N-methylcarbamates at a level of 10 microg/L. All analytes showed very good recoveries (>86%), except for the most polar analyte aldicarb sulfone (recovery of 73%), testifying for the potential use of APFOA for this kind of analyses.
Collapse
|
40
|
Zheng J, Shamsi SA. Simultaneous enantioseparation and sensitive detection of eight beta-blockers using capillary electrochromatography-electrospray ionization-mass spectrometry. Electrophoresis 2006; 27:2139-51. [PMID: 16645981 DOI: 10.1002/elps.200500874] [Citation(s) in RCA: 41] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
The feasibility of using vancomycin chiral stationary phase (CSP) and polar organic eluent is investigated for simultaneous enantioseparation of eight beta-blockers using CEC coupled to ESI mass spectrometric detection (ESI-MS). The internally tapered capillaries were utilized to pack CEC-MS columns. As compared to externally tapered columns, the use of internally tapered columns demonstrated enhanced stability, durability, and reproducibility. A mixture containing methanol/ACN/acetic acid/triethylamine at 70:30:1.6:0.2 v/v/v/v was considered as optimum mobile phase since it provided a good compromise between resolution and analysis time. As expected, sheath liquid and ESI-MS parameters mainly influenced the detection sensitivity. Interestingly, structural information of beta-blockers was available by varying the MS fragmentor voltage using in-house CID in the scan mode. In order to maximize the chiral/achiral resolution, various column-coupling approaches using teicoplanin as complementary CSP to vancomycin were tested. Several changes in the elution order of beta-blockers were observed using multimodal CSPs with some improvement in chiral or achiral resolution. The quantitative aspects of the CEC-MS method were demonstrated using R- and S-talinolol as internal standards. The calibration curves of beta-blockers showed good linearity in the range of 3-600 microM. The enantiomer of beta-blockers at a concentration of 30 nM was detectable. Furthermore, both 0.1 and 1% of the S-enantiomer could be precisely quantified in the presence of 99.9 and 99% of the R-isomer of beta-blocker.
Collapse
Affiliation(s)
- Jack Zheng
- Department of Chemistry, Center of Biotechnology and Drug Design, Georgia State University, Atlanta, 30302, USA
| | | |
Collapse
|
41
|
Zheng J, Shamsi SA. Capillary Electrochromatography Coupled to Atmospheric Pressure Photoionization Mass Spectrometry for Methylated Benzo[a]pyrene Isomers. Anal Chem 2006; 78:6921-7. [PMID: 17007515 DOI: 10.1021/ac061024c] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Benzo[a]pyrene, one of the most carcinogenic PAHs, has 12 monomethylated positional isomers (MBAPs). A strong correlation between the carcinogenicity of these isomers and methyl substitution has been reported. In this study, on-line coupling of capillary electrochromatography (CEC) and atmospheric pressure photoionization mass spectrometry (APPI-MS) provides a unique solution to highly selective separation and sensitive detection of MBAP isomers. The studies indicated that APPI provides significantly better sensitivity compared to electrospray ionization and atmospheric pressure chemical ionization modes of MS. A systematic investigation of APPI-MS detection parameters and CEC separation is established. First, several sheath liquid parameters (including type and concentration of volatile buffers, type and content of organic modifiers, use of dopants and inorganic/organic additives, and sheath liquid flow rate) and APPI-MS spray chamber parameters (capillary voltage, vaporizer temperature, nebulizer pressure) were found to have effects on detection sensitivity as well as the profile of mass spectrum. For example, when ammonium acetate was replaced with acetic acid in the sheath liquid, the MS signal was enhanced as much as 90% and the formation of ammonia adduct was effectively suppressed. Next, the separation of MBAP isomers was conducted on internal tapered columns packed with polymeric C18 stationary phase. With the use of a mobile phase consisting of slightly higher acetonitrile content (90%,v/v) and a small amount of tropylium ion, the analysis times were significantly shortened by 20 min without compromising the resolutions between the isomers. Finally, quantitative aspects of the CEC-APPI-MS method were demonstrated using 7-MBAP as the internal standard. The calibration curves of three of the most carcinogenic isomers, namely, 1-MBAP, 3-MBAP, and 11-MBAP, showed good linearity in the range of 2.5-50 microg/mL with a limit of detection at 400 ng/mL.
Collapse
Affiliation(s)
- Jie Zheng
- Department of Chemistry, Center of Biotechnology and Drug Design, Georgia State University, Atlanta, Georgia 30303, USA
| | | |
Collapse
|
42
|
Merino F, Rubio S, Pérez-Bendito D. Supramolecular systems-based extraction-separation techniques coupled to mass spectrometry. J Sep Sci 2006; 28:1613-27. [PMID: 16224955 DOI: 10.1002/jssc.200500161] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
The combination of supramolecular chemistry and MS has not only been fruitful in the field of gas-phase fundamental studies of host-guest complexes and supramolecular assemblies. Mass spectrometric analysis has also benefited from the ability of supramolecular systems to behave as pseudophases in which solutes partition from the bulk solvent phase. Supramolecular systems-based extraction and concentration schemes and separation techniques have been widely used in different fields of analytical chemistry and are ideally suited for coupling with MS. This review describes the present status of the application of supramolecular chemistry in mass spectrometric analysis and includes topics such as the use of coacervative liquid-liquid extraction and hemimicelle/admicelle-based SPE of organic compounds prior to chromatography and electrophoresis. It also discusses the recent advances in enantioselective analysis using CD in electrophoresis- and chromatography-MS. The potential and analytical challenges of these approaches in environmental and bioanalytical chemistry, where one can expect significant developments in the future, are outlined.
Collapse
Affiliation(s)
- Francisco Merino
- Department of Analytical Chemistry, Campus de Rabanales, Edificio Anexo Marie Curie, University of Córdoba, Córdoba, Spain
| | | | | |
Collapse
|
43
|
Servais AC, Crommen J, Fillet M. Capillary electrophoresis-mass spectrometry, an attractive tool for drug bioanalysis and biomarker discovery. Electrophoresis 2006; 27:2616-29. [PMID: 16817163 DOI: 10.1002/elps.200500934] [Citation(s) in RCA: 62] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
The coupling of CE with MS detection, a relatively recent hyphenated technique, has gained increasing respect in the field of bioanalytical applications over the past few years. The first part of this review presents CE-MS applications dealing with drug bioanalysis, including forensic analysis and metabolism studies. Practical considerations to achieve a robust and sensitive CE-MS coupling are also presented. It is indeed essential to strictly control some critical electrospray parameters, such as the sheath liquid composition and flow rate, the nebulizing gas pressure as well as the capillary outlet position. The second part of the review critically describes the applications of CE coupled on-line to MS for the identification of biomarkers in body fluids for diagnostic purposes. Since the sample preparation procedures strongly differ according to the intended use (drug bioanalysis or biomarker discovery), they are discussed separately, taking into account the particular properties of plasma and urine matrices.
Collapse
Affiliation(s)
- Anne-Catherine Servais
- Department of Analytical Pharmaceutical Chemistry, Institute of Pharmacy, University of Liège, Belgium
| | | | | |
Collapse
|
44
|
Affiliation(s)
- Timothy J Ward
- Millsaps College, 1701 North State Street, Box 150306, Jackson, Mississippi, USA.
| |
Collapse
|
45
|
Altria K, Marsh A, Sänger-van de Griend C. Capillary electrophoresis for the analysis of small-molecule pharmaceuticals. Electrophoresis 2006; 27:2263-82. [PMID: 16786477 DOI: 10.1002/elps.200600030] [Citation(s) in RCA: 68] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
This paper reviews the application of CE to the analysis of small-molecule pharmaceuticals. The areas of pharmaceutical analysis covered are enantiomer separation, the analysis of small molecules such as amino acids or drug counter-ions, pharmaceutical assay, determination of related substances and physicochemical measurements such as log P and pK(a) of compounds. The different electrophoretic modes available and their advantages for pharmaceutical analysis are described. Recent applications of CE for each subject area are tabulated with electrolyte details.
Collapse
Affiliation(s)
- Kevin Altria
- GlaxoSmithKline Research & Development, Harlow, Essex, UK.
| | | | | |
Collapse
|
46
|
Benavente F, Balaguer E, Barbosa J, Sanz-Nebot V. Modelling migration behavior of peptide hormones in capillary electrophoresis-electrospray mass spectrometry. J Chromatogr A 2006; 1117:94-102. [PMID: 16616758 DOI: 10.1016/j.chroma.2006.03.049] [Citation(s) in RCA: 35] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2005] [Revised: 03/05/2006] [Accepted: 03/20/2006] [Indexed: 10/24/2022]
Abstract
The applicability in capillary electrophoresis-electrospray mass spectrometry (CE-ESI-MS) of the classical semiempirical relationships between electrophoretic mobility and charge-to-mass ratio (me versus q/Malpha) has been investigated in order to describe the migration behavior of a series of bioactive peptide hormones. The influence upon the models of the separation electrolyte pH and the accuracy of the pK values of these compounds were studied first by capillary electrophoresis with ultraviolet detection (CE-UV). The classical polymer model, alpha = 1/2, resulted in slightly better correlations at any of the studied pH. Furthermore, a general linear equation can be adjusted combining all the experimental data pairs, which suggests that correlation in the whole pH range is independent of the ionic form of the studied peptide hormones. The plots of q/M1/2 against separation electrolyte pH were used to predict their electrophoretic separations, using the accurate pK values obtained in a previous work by CE-UV for charge calculations. A volatile separation electrolyte containing 50 mM of acetic acid and 50 mM of formic acid at pH 2.85 was selected for optimum CE-UV and CE-ESI-MS analysis of the peptide mixture. At this pH and taking into account the specific features of the coupling, the correlation using the classical polymer law was excellent and its parameters were similar to the ones of the general linear equation previously obtained by CE-UV. This confirmed the applicability in CE-ESI-MS of the semiempirical relationship originally established by CE-UV.
Collapse
Affiliation(s)
- Fernando Benavente
- Department of Analytical Chemistry, University of Barcelona, Diagonal 647, 08028 Barcelona, Spain.
| | | | | | | |
Collapse
|
47
|
Campa C, Coslovi A, Flamigni A, Rossi M. Overview on advances in capillary electrophoresis-mass spectrometry of carbohydrates: A tabulated review. Electrophoresis 2006; 27:2027-50. [PMID: 16736462 DOI: 10.1002/elps.200500960] [Citation(s) in RCA: 88] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
The increasing interest for carbohydrates as holder of essential bioinformations has boosted their full characterization through analytical techniques. The intent of this review is to summarize the recent trends regarding on-line and off-line CE-MS coupling for carbohydrate analysis. A statistical survey on the articles that use derivatizing agents as well as on the analyzer and type of instrument coupling (i.e. on- or off-line) is depicted. From a general overview it can be concluded that, whereas derivatization might be useful for the detection of neutral carbohydrates improving separation selectivity with volatile buffers and increasing sensitivity of the MS detection, relatively few works with derivatized carbohydrates were found; this was noticed in particular for glycosides and saccharides carrying ionizable groups, which are normally analyzed without any chemical modification. The most applied coupling is the on-line sheath-liquid interface; for on-line applications, ESI is the sole source used, whilst the most common analyzer is the IT. MS(n) is often exploited, as fragmentation increases the achieved structural information. CE-MS turned out to be mainly used for the analysis of carbohydrates in drug development (i.e. study of oligosaccharides from pathogens, carbohydrate-based drugs and drug metabolites), in nutrition and for characterization of glycans from glycoproteins. The reader will find elucidating tables regarding these recent CE-MS applications, including the main information on the analysis conditions. Comments are meant to help the immediate focus on the usefulness of the analytical technique and predict the difficulties found during analysis and, in case, their overcoming.
Collapse
|
48
|
Kitagawa F, Inoue K, Hasegawa T, Kamiya M, Okamoto Y, Kawase M, Otsuka K. Chiral separation of acidic drug components by open tubular electrochromatography using avidin immobilized capillaries. J Chromatogr A 2006; 1130:219-26. [PMID: 16600258 DOI: 10.1016/j.chroma.2006.03.077] [Citation(s) in RCA: 42] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2006] [Revised: 03/17/2006] [Accepted: 03/22/2006] [Indexed: 10/24/2022]
Abstract
Avidin was immobilized covalently onto the inner surface of fused silica capillaries as a stationary phase in an open tubular capillary electrochromatography (OT-CEC) for chiral separations. The modification was attained by a combination of glutaraldehyde with both an amino-silylated fused silica surface and avidin using a Schiff base formation reaction. This method couples the advantage of high efficiency and small consumption of a chiral selector with the possibility of UV detection without limitations of protein absorption. In addition, the prepared capillary was stable for 50 days with over 100 runs. To evaluate the electrochromatographic performance of the prepared capillaries, the chiral separation of abscisic acid and arylpropionic acids were investigated. Effects of the modification condition of protein, pH of running buffer, and an organic modifier on the enantioseparation were also investigated. In addition, the avidin immobilized capillary was employed for the selective chiral analysis with an electrospray ionization mass spectrometry (ESI-MS) detection scheme.
Collapse
Affiliation(s)
- Fumihiko Kitagawa
- Department of Material Chemistry, Graduate School of Engineering, Kyoto University, Katsura, Kyoto 615-8510, Japan.
| | | | | | | | | | | | | |
Collapse
|
49
|
Ha PTT, Hoogmartens J, Van Schepdael A. Recent advances in pharmaceutical applications of chiral capillary electrophoresis. J Pharm Biomed Anal 2006; 41:1-11. [PMID: 16516428 DOI: 10.1016/j.jpba.2006.01.035] [Citation(s) in RCA: 97] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2005] [Revised: 01/05/2006] [Accepted: 01/19/2006] [Indexed: 11/28/2022]
Abstract
This review article summarizes developments and applications of chiral capillary electrophoresis (CE) in the pharmaceutical field published from January 2004 to June 2005. Due to the tremendous number of publications, this article is aimed to focus on major developments in chiral separations and some selected applications rather than to provide a descriptive overview of all published papers. Valuable information is also collected from several excellent reviews published during this period. Developments are classified according to CE modes, namely capillary zone electrophoresis (CZE), micellar electrokinetic capillary chromatography (MEKC), microemulsion electrokinetic chromatography (MEEKC). In the CZE section, different types of chiral selectors including cyclodextrins, oligo- and polysaccharides, crown ethers, macrocyclic antibiotics, ligand exchange systems and proteins are described. Nonaqueous capillary electrophoresis is also included in this section. Coupling CE to MS is discussed in a separate part, followed by a summary of selected pharmaceutical applications of enantioselective CE. Finally, some conclusions are drawn and prospects of CE in chiral analysis are also drafted.
Collapse
Affiliation(s)
- Pham Thi Thanh Ha
- Laboratory of Pharmaceutical Chemistry and Drug Analysis, Faculty of Pharmaceutical Sciences, K.U. Leuven, Leuven, Belgium
| | | | | |
Collapse
|
50
|
Schappler J, Guillarme D, Prat J, Veuthey JL, Rudaz S. Enhanced method performances for conventional and chiral CE-ESI/MS analyses in plasma. Electrophoresis 2006; 27:1537-46. [PMID: 16532520 DOI: 10.1002/elps.200500805] [Citation(s) in RCA: 33] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Due to its high efficiency, selectivity, and sensitivity, CE-ESI/MS has evolved as an efficient technique for the drugs and metabolites analysis in biological matrices. However, a sample preparation is mandatory prior to CE-ESI/MS analysis. To achieve fast and simplified sample preparation of plasma samples, protein precipitation (PP) and liquid-liquid extraction (LLE) were used with two injection techniques: hydrodynamic (HD) and electrokinetic (EK) injection. CE-ESI/MS analyses of pharmaceutical compounds and amphetamine derivatives were developed. Detection limits of 1 ppm were reached with PP and HD injection whereas 1 ppb was detected when samples were prepared with LLE and injected by EK. Same experiments were performed for stereoselective determinations in partial-filling mode and detection limits achieved were equivalent to conventional analysis (0.5 ppb per enantiomer). When complex matrices are analyzed, MS signal suppression or enhancement effects are generally not reproducible and could compromise results with ESI. Therefore, matrix effect was investigated in CE-ESI/MS with a commercially available coaxial sheath-liquid ESI interface used as postcapillary infusion system to determine MS signal alterations. Matrix effects were differentially evidenced according to the selected sample preparation. With PP, signal suppression was observed out of the analyses migration window, while for LLE no relevant matrix effect occurred in all experiments.
Collapse
Affiliation(s)
- Julie Schappler
- Laboratory of Pharmaceutical Analytical Chemistry, School of Pharmaceutical Sciences, University of Geneva, University of Lausanne,Geneva, Switzerland
| | | | | | | | | |
Collapse
|