1
|
Kohring A, Parikh N, Hobbs J, Lowitz S, Gold P, Krueger CA. The Effect of Cemented Implants Placed During Initial TKA on Surgical Time and Expenses in Revision TKA. J Am Acad Orthop Surg 2025; 33:75-82. [PMID: 38759227 DOI: 10.5435/jaaos-d-23-01184] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/08/2023] [Accepted: 04/18/2024] [Indexed: 05/19/2024] Open
Abstract
INTRODUCTION Revision total knee arthroplasty (rTKA) is a complex procedure that often requires the removal of previous implants. There is little information evaluating the difference between removing cemented or noncemented knee prostheses in revision surgeries. The purpose of this study was to determine whether removing cemented or noncemented implants would affect surgical time and expenses incurred during revision procedures. METHODS This retrospective cohort study used a single-institution database to identify 300 patients who underwent femoral and tibial implant rTKA from 2016 to 2022 because of mechanical complications (infection cases excluded). Radiographs and surgical reports were used to confirm whether the fixation technique was cemented (N = 243) or noncemented (N = 57). The primary outcomes were surgical time and surgery costs. Secondary outcomes included readmission rates, revision implants used, stem usage, and insurance type. RESULTS The average surgical time was 121 minutes for noncemented and 128 minutes for cemented procedures ( P = 0.118). The 90-day readmission rates for each group were similar at 7.00% for the cemented cohort and 8.77% for the noncemented cohort ( P = 0.643). For patients with Medicare Advantage, the respective surgery costs were $1,966 for noncemented and $1,968 for cemented TKA ( P = 0.988). For patients with commercial insurance, the respective surgery costs were $4,854 for noncemented and $5,660 for cemented TKA ( P = 0.330). CONCLUSION Primary knee fixation type, cemented or noncemented, did not appear to influence the surgical duration or surgical costs of both-implant revision knee surgery indicated for mechanical complications.
Collapse
Affiliation(s)
- Adam Kohring
- From the Jefferson Health New Jersey (Kohring), Rothman Orthopaedic Institute at Thomas Jefferson University, Philadelphia, PA (Parikh, Hobbs, and Krueger), Midwestern University, Downers Grove, IL (Lowitz), and Panorama Orthopedic & Spine Center, Golden, CO (Gold)
| | | | | | | | | | | |
Collapse
|
2
|
Wolfert AJ, Tischler EH, Govind J, Tracey OC, Elali F, Mai DH, Baksh N, Naziri Q. All-Polyethylene Tibias Equal to Metal-Backed Tibias in Primary Total Knee Arthroplasty: A Systematic Review and Meta-Analysis. J Long Term Eff Med Implants 2025; 35:1-16. [PMID: 39704595 DOI: 10.1615/jlongtermeffmedimplants.2024048286] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2024]
Abstract
We sought to conduct a systematic review of the literature and a meta-analysis of post-operative outcomes following TKA with an all-polyethylene tibial (APT) or a metal-backed tibial component (MBT). A systematic review of the literature was conducted to identify all studies comparing APT and MBT for TKA based upon rates of complications, revisions, reoperation, and patient-reported outcomes. Data was pooled and relative risk of each outcome measure at short (< 5 year), mid (5-10 year), and long (> 10 year) follow-up was calculated. Thirty-eight studies met criteria and were included for analysis, totaling 113,413 primary TKAs performed in 106,490 patients. Of these, 21,752 were performed with an APT and 91,661 with an MBT. APT had a statistically significant decrease in the relative risk of revisions, reoperations, total complications, septic complications, and aseptic complications at one-to-five-year follow-up. There was no statistically significant difference in the relative risk of these metrics between APT and MBT beyond 5 years. This study demonstrates that patients with APT components, compared to the MBT tibial components, had significantly lower rates of complications and revisions at 1-to-5-year follow-up, and no difference in these metrics beyond five years. Further prospective studies are warranted for better external validity of results found in this study.
Collapse
Affiliation(s)
| | - Eric H Tischler
- Department of Orthopaedic Surgery and Rehabilitation Medicine, State University of New York, Downstate Health Sciences University, Brooklyn, NY, USA
| | - Jigar Govind
- Department of Orthopaedic Surgery and Rehabilitation Medicine, State University of New York, Downstate Health Sciences University, Brooklyn, NY, USA
| | - Olivia C Tracey
- Department of Orthopaedic Surgery and Rehabilitation Medicine, State University of New York, Downstate Health Sciences University, Brooklyn, NY, USA
| | - Faisal Elali
- Department of Orthopaedic Surgery and Rehabilitation Medicine, State University of New York (SUNY) Downstate Health Sciences University, Brooklyn, NY
| | - David H Mai
- Department of Orthopaedic Surgery and Rehabilitation Medicine, State University of New York, Downstate Health Sciences University, Brooklyn, NY, USA
| | - Nayeem Baksh
- Department of Orthopaedic Surgery and Rehabilitation Medicine, State University of New York, Downstate Health Sciences University, Brooklyn, NY, USA
| | - Qais Naziri
- Department of Orthopaedic Surgery and Rehabilitation, SUNY Downstate Medical Center, Brooklyn, NY 11203, USA
| |
Collapse
|
3
|
Schaffler BC, Robin JX, Katzman J, Arshi A, Rozell JC, Schwarzkopf R. Aseptic Tibial Loosening is Associated with Thickness of the Cement: A Radiographic Case-Control Study. J Arthroplasty 2024:S0883-5403(24)01326-3. [PMID: 39710212 DOI: 10.1016/j.arth.2024.12.023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/01/2024] [Revised: 12/15/2024] [Accepted: 12/17/2024] [Indexed: 12/24/2024] Open
Abstract
BACKGROUND The cementation technique is crucial for achieving adequate fixation and optimal survivorship in total knee arthroplasty (TKA). The thickness of the cement at the tibial bone-implant surface may be related to aseptic tibial loosening. However, to date, no studies have demonstrated a direct association between cement thickness and rates of aseptic tibial loosening. METHODS We performed a retrospective review to identify 28,327 primary cemented TKAs with at least two years of follow-up at an academic health system from 2013 to 2021. A total of 115 cases underwent revision surgery for aseptic tibial loosening. Cases where the implant was recalled specifically for loosening (n = 23) were excluded. The remaining 92 aseptic tibial loosening cases were 2:1 propensity score matched and implant-matched to control patients who did not have tibial loosening. There were two independent reviewers who then measured the thickness of the cement interface in ten locations along the bone-implant interface from initial postoperative radiographs. The averages of the reviewers' measurements were calculated and then compared using independent t-tests. RESULTS Aseptic tibial loosening cases involving implant A tibial baseplate (n = 75) had significantly thinner cement interfaces than matched controls at all ten locations measured. Aseptic loosening cases involving implant B (n = 17) also displayed a thinner cement interface than matched controls in all locations, but this result was only statistically significant at the medial baseplate, medial keel, lateral keel, anterior keel, and posterior baseplate. CONCLUSION In two widely used TKA systems, tibial aseptic loosening was associated with significantly thinner cement interfaces when compared to propensity-matched controls in two different implant types. Further prospective studies are needed to identify the optimal keel preparation and design as well as minimal cement interface thickness to avoid implant loosening.
Collapse
|
4
|
Karlidag T, Zanna L, Traverso G, Lee MJ, Gehrke T, Citak M. Assessing the reliability of automated cell count analysis of synovial fluid in the setting of revision total knee arthroplasty. Arch Orthop Trauma Surg 2024; 145:25. [PMID: 39666043 DOI: 10.1007/s00402-024-05652-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/19/2024] [Accepted: 10/21/2024] [Indexed: 12/13/2024]
Abstract
PURPOSE The diagnostic challenges of periprosthetic joint infection (PJI) for orthopedic surgeons are significant. Prior research has indicated that patients with adverse reactions, dislocations, and aseptic loosening exhibit a heightened count of white blood cells (WBC) in their synovial fluid, along with an increased polymorphonuclear cell percentage (PMN%). The prevalence of false-positive results raises concerns about the reliability of these tools in distinguishing aseptic failure from PJI. METHODS We have performed a retrospective inquiry of the medical records of all patients who have undergone aseptic revision total knee arthroplasty (TKA) at our tertiary referral arthroplasty center. We conducted an assessment on 552 knees by applying the guidelines set forth by the 2018 International Consensus Meeting. Recorded preoperative parameters: aspiration results (WBC, PMN%, and AD immunoassay), preoperative and intraoperative diagnoses, microbiologic and histopathologic findings from periprosthetic tissue samples, and prosthetic details. RESULTS Among the causes of aseptic revision investigated, patients with polyethylene wear exhibited the highest median WBC count (median 1091 cells/µL, range 83.5-1715.5 cells/µL; p = 0.010). Concerning periprosthetic conditions, patients with wear-induced synovitis exhibited a significantly higher synovial fluid WBC count (median 1093 cells/µL, range 587-1683 cells/µL; p < 0.001). Among all the reasons for failure, periprosthetic fractures had the greatest percentage of WBC counts surpassing 3000 cells/µL (18.1% [2 of 11]; p = 0.006). CONCLUSION Our study has uncovered significant variations in WBC count during aseptic revision TKA when utilizing automated cell counting. Therefore, to optimize diagnostic accuracy in synovial aspiration during aseptic revision TKA, it is advisable to employ a combination of WBC count and PMN%, along with manual counting techniques or AD, depending on the specific clinical scenario. LEVEL OF EVIDENCE III.
Collapse
Affiliation(s)
- Taner Karlidag
- Department of Orthopedics and Traumatology, Helios ENDO-Klinik Hamburg, Holstenstr. 2, 22767, Hamburg, Germany
| | - Luigi Zanna
- Department of Orthopedics and Traumatology, Helios ENDO-Klinik Hamburg, Holstenstr. 2, 22767, Hamburg, Germany
| | - Giacomo Traverso
- Department of Orthopedics and Traumatology, Helios ENDO-Klinik Hamburg, Holstenstr. 2, 22767, Hamburg, Germany
| | - Min-Jae Lee
- Department of Orthopedics and Traumatology, Helios ENDO-Klinik Hamburg, Holstenstr. 2, 22767, Hamburg, Germany
| | - Thorsten Gehrke
- Department of Orthopedics and Traumatology, Helios ENDO-Klinik Hamburg, Holstenstr. 2, 22767, Hamburg, Germany
| | - Mustafa Citak
- Department of Orthopedics and Traumatology, Helios ENDO-Klinik Hamburg, Holstenstr. 2, 22767, Hamburg, Germany.
| |
Collapse
|
5
|
Yapar A, Köse Ö, Özdöl Ç, Luo TD, Budin M, Rosa GF, Gehrke T, Citak M. Increased Involvement of Staphylococcus epidermidis in the Rise of Polymicrobial Periprosthetic Joint Infections. J Arthroplasty 2024; 39:3056-3061. [PMID: 38823523 DOI: 10.1016/j.arth.2024.05.075] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/09/2024] [Revised: 05/26/2024] [Accepted: 05/27/2024] [Indexed: 06/03/2024] Open
Abstract
BACKGROUND In this study, we aimed to analyze the temporal distribution of polymicrobial periprosthetic joint infections (PJIs), while also evaluating the patient risk factors associated with these infections following total joint arthroplasty at our institution across 2 distinct periods. METHOD This retrospective cross-sectional study evaluated 259 patients who had knee or hip PJI from 2001 to 2006 and 2018 to 2022. A PJI was diagnosed using the 2018 International Consensus Meeting criteria. We utilized the Polymicrobial Pathogens' Co-occurrence Network Analysis, a novel approach that leverages network theory to map and quantify the complex interplay of organisms in PJIs. RESULTS Of the 259 patients who had polymicrobial PJI, 58.7% were men, with mean age 67 years (range, 24 to 90). Of the 579 identified pathogens, Staphylococcus epidermidis was the most common (22.1%), followed by Staphylococcus aureus (9.0%) and Cutibacterium acnes (7.8%). The co-occurrence analysis indicated that Staphylococcus epidermidis frequently coexisted with Cutibacterium acnes (26 cultures) and Staphylococcus capitis (22 cultures). A notable increase in body mass index from 27.7 ± 4.4 in 2001 to 2006 to 29.7 ± 6.2 in 2018 to 2022 was observed (P = .001). Moreover, infections from Staphylococcus epidermidis, Cutibacterium acnes, and Staphylococcus capitis saw a significant uptick (P < .001). CONCLUSIONS The study shows that from 2001 to 2022, there was a significant change in the pathogens responsible for polymicrobial PJIs, particularly an increase in Staphylococcus epidermidis, Cutibacterium acnes, and Staphylococcus capitis. Alongside these microbial changes, there was a rise in body mass index and shifts in comorbid conditions, such as more renal disease and fewer cases of congestive heart failure. These changes highlight the dynamic interplay between host and microbial factors in the pathogenesis of polymicrobial PJIs, necessitating adaptive strategies in both surgical and postoperative care to mitigate the rising tide of these complex infections.
Collapse
Affiliation(s)
- Aliekber Yapar
- Department of Orthopaedic Surgery, ENDO-Klinik Hamburg, Hamburg, Germany; Department of Orthopedics and Traumatology, Antalya Training and Research Hospital, Antalya, Turkey
| | - Özkan Köse
- Department of Orthopedics and Traumatology, Antalya Training and Research Hospital, Antalya, Turkey
| | - Çağla Özdöl
- Department of Orthopaedic Surgery, ENDO-Klinik Hamburg, Hamburg, Germany
| | - T David Luo
- Department of Orthopaedic Surgery, ENDO-Klinik Hamburg, Hamburg, Germany; Division of Adult Reconstruction, Orthopaedics Northeast, Fort Wayne, Indiana
| | - Maximilian Budin
- Department of Orthopaedic Surgery, ENDO-Klinik Hamburg, Hamburg, Germany
| | - Gianmaria F Rosa
- Department of Orthopaedic Surgery, ENDO-Klinik Hamburg, Hamburg, Germany
| | - Thorsten Gehrke
- Department of Orthopaedic Surgery, ENDO-Klinik Hamburg, Hamburg, Germany
| | - Mustafa Citak
- Department of Orthopaedic Surgery, ENDO-Klinik Hamburg, Hamburg, Germany
| |
Collapse
|
6
|
Kurtz MA, Gilbert JL, Spece H, Klein GR, Cates HE, Kurtz SM. Tibial Baseplate Microstructure Governs High Cycle Fatigue Fracture In Vivo. J Biomed Mater Res B Appl Biomater 2024; 112:e35507. [PMID: 39570093 DOI: 10.1002/jbm.b.35507] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2024] [Accepted: 10/13/2024] [Indexed: 11/22/2024]
Abstract
Previous studies report rare occurrences of tibial baseplate fractures following primary total knee arthroplasty (TKA). However, at a microstructural scale, it remains unclear how fatigue models developed in vitro apply to fractures in vivo. In this study, we asked: (1) do any clinical factors differentiate fracture patients from a broader revision sample; and (2) in vivo, how does microstructure influence fatigue crack propagation? We identified three fractured tibial baseplates from an institutional review board exempt implant retrieval program. Then, for comparison, we collated clinical data from the same database for n = 2120 revision TKA patients with tibial trays. To identify mechanisms, we characterized fracture features using scanning electron and digital optical microscopy. Additionally, we performed cross sectional analysis using focused ion beam milling. The fracture cohort consisted of moderately to very active patients with increased implantation time (15.6 years) compared to the larger revision patient sample (5.1 years, p = 0.009). We did not find a significant difference in patient weight between the two groups (p = 0.98). Macroscopic fracture features aligned well with both previous retrieval analysis and in vitro baseplate fatigue tests. On a micron scale, we identified striations on each baseplate, demonstrating fatigue as the fracture mechanism. In vivo fatigue fracture processes depended on both the alloy (Ti-6Al-4V vs. CoCrMo) and the microstructure of the alloy formed during manufacturing. For Ti-6Al-4V, the presence of equiaxed or acicular microstructure influenced the fatigue crack propagation, the latter arising from large prior β grains and a Widmanstatten microstructure, degrading fatigue strength. CoCrMo alloy fatigue cracks propagated linearly, crystallographically influenced by planar slip. However, we did not document any features of overload or fast fracture, suggesting a high cycle, low stress fatigue regime. Ultimately, the crack profiles we present here may provide insight into fatigue fractures of modern tibial baseplates.
Collapse
Affiliation(s)
- Michael A Kurtz
- Implant Research Core, School of Biomedical Engineering, Science, and Health Systems, Drexel University, Philadelphia, Pennsylvania, USA
| | - Jeremy L Gilbert
- Department of Bioengineering, Clemson University, Clemson, South Carolina, USA
- The Clemson University-Medical University of South Carolina Bioengineering Program, Charleston, South Carolina, USA
| | - Hannah Spece
- Implant Research Core, School of Biomedical Engineering, Science, and Health Systems, Drexel University, Philadelphia, Pennsylvania, USA
| | - Gregg R Klein
- Department of Orthopaedic Surgery, Hackensack University Medical Center, Hackensack, New Jersey, USA
| | | | - Steven M Kurtz
- Implant Research Core, School of Biomedical Engineering, Science, and Health Systems, Drexel University, Philadelphia, Pennsylvania, USA
| |
Collapse
|
7
|
Hauer G, Rasic L, Klim S, Leitner L, Leithner A, Sadoghi P. Septic complications are on the rise and aseptic loosening has decreased in total joint arthroplasty: an updated complication based analysis using worldwide arthroplasty registers. Arch Orthop Trauma Surg 2024; 144:5199-5204. [PMID: 38795186 PMCID: PMC11602841 DOI: 10.1007/s00402-024-05379-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/18/2023] [Accepted: 05/07/2024] [Indexed: 05/27/2024]
Abstract
INTRODUCTION A decade ago, a comprehensive study was conducted to investigate the reasons for revision surgeries and their respective frequencies in cases of total hip arthroplasty (THA) and total knee arthroplasty (TKA) based on a complication-based analysis of joint replacement registries. The aim of the present study was to determine whether the causes and risks of their occurrence have changed over the last ten years and to present an updated analysis. MATERIALS AND METHODS A systematic review of national arthroplasty registries from seven countries examined the causes and rates of revisions of THA and TKA. The study focused on a descriptive analysis that provided an updated overview without statistical significance values. RESULTS The most common causes for revisions of THA were aseptic loosening (35.1%), deep infection (18.2%), dislocation/instability (15.9%), and periprosthetic fractures (11.4%). The most common causes for revisions of TKA were deep infection (21.6%), aseptic loosening (18.3%), instability (14.1%), and pain (10.9%). CONCLUSION The findings of this study revealed significant shifts in the underlying causes of revision surgeries in the last decade. Notably, septic complications emerged as the predominant reason for revision of primary TKA, while they also gained prominence as a cause of failure of THA. Although aseptic loosening remains the primary cause for re-operation of THA, the relative risk has decreased for both THA and TKA.
Collapse
Affiliation(s)
- Georg Hauer
- Department of Orthopaedics and Trauma, Medical University of Graz, Auenbruggerplatz 5, Graz, 8036, Austria.
| | - Laura Rasic
- Department of Orthopaedics and Trauma, Medical University of Graz, Auenbruggerplatz 5, Graz, 8036, Austria
| | - Sebastian Klim
- Department of Orthopaedics and Trauma, Medical University of Graz, Auenbruggerplatz 5, Graz, 8036, Austria
| | - Lukas Leitner
- Department of Orthopaedics and Trauma, Medical University of Graz, Auenbruggerplatz 5, Graz, 8036, Austria
- Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), LMU University Hospital, Munich, Germany
| | - Andreas Leithner
- Department of Orthopaedics and Trauma, Medical University of Graz, Auenbruggerplatz 5, Graz, 8036, Austria
| | - Patrick Sadoghi
- Department of Orthopaedics and Trauma, Medical University of Graz, Auenbruggerplatz 5, Graz, 8036, Austria
| |
Collapse
|
8
|
Salvi AG, Valpiana P, Innocenti B, Ghirardelli S, Bernardi M, Petralia G, Aloisi G, Zepeda K, Schaller C, Indelli PF. The Restoration of the Prearthritic Joint Line Does Not Guarantee the Natural Knee Kinematics: A Gait Analysis Evaluation Following Primary Total Knee Arthroplasty. Arthroplast Today 2024; 30:101586. [PMID: 39717836 PMCID: PMC11665368 DOI: 10.1016/j.artd.2024.101586] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/30/2024] [Revised: 10/07/2024] [Accepted: 11/06/2024] [Indexed: 12/25/2024] Open
Abstract
Background Unrestricted kinematic alignment (uKA) in total knee arthroplasty (TKA) has the theoretical advantage of reproducing patients' constitutional alignment and restoring the pre-arthritic joint line position and obliquity. However, modifications of the original uKA technique have been proposed due to the potential risk of mechanical failure and instability. Given the significant variability in soft tissue behavior within the same bony morphology group, uKA pure knee resurfacing could be occasionally detrimental. This study aimed to kinematically compare the outcomes of uKA TKA with those of a robotic-assisted KA TKA technique based on specific soft-tissue boundaries. Methods In this retrospective gait analysis study, 24 TKA patients and 12 healthy controls were recruited. Inclusion criteria were a 9-month minimum follow-up from successfully, primary medial-pivot or medially-congruent TKA performed for isolated degenerative joint disease. Preoperatively, patients were randomly assigned to two surgical groups: A) uKA (#12) and B) robot-assisted (#12), KA (hybrid-kinematic) with boundaries (±3° from hip-knee-ankle neutral axis) and a slight intercompartmental gap asymmetry (max 2 mm lateral-opening). The gait analysis was performed using instrumented treadmills equipped with 3D cameras. Results Sagittal knee kinematic data: during the early-stance phase of gait, the uKA group showed a less consistent weight-acceptance phase and a less efficient transition between the first knee-flexion peak and mid-stance-extension plateau with respect to the hybrid-kinematic alignment group. Spatiotemporal and overall gait quality data: no significant differences were found between the two TKA groups regarding walking speed (P = .51) and step length (P = .8534). Control group patients walked more efficiently compared to TKA groups, showing inferior trunk flexion and inferior variation in step length (P < .0001). Conclusions This study showed that restoring the pre-arthritic joint line, as advocated by surgeons following the uKA philosophy, does not guarantee a closer-to-normal knee kinematics.
Collapse
Affiliation(s)
- Andrea Giordano Salvi
- Südtiroler Sanitätsbetrieb, Department Orthopaedic Surgery, Brixen, Italy
- Hôpital Maisonneuve-Rosemont, Department Orthopaedic Surgery, Montréal, Quebec, Canada
| | - Pieralberto Valpiana
- Südtiroler Sanitätsbetrieb, Department Orthopaedic Surgery, Brixen, Italy
- Personalized Arthroplasty Society (PAS), Atlanta, GA, USA
- Paracelsus Medical University (PMU), Institute of Biomechanics, Salzburg, Austria
| | - Bernardo Innocenti
- Personalized Arthroplasty Society (PAS), Atlanta, GA, USA
- Université Libre de Bruxelles, BEAMS Department (Bio Electro and Mechanical Systems), Bruxelles, Belgium
| | | | - Matteo Bernardi
- Südtiroler Sanitätsbetrieb, Department Orthopaedic Surgery, Brixen, Italy
| | - Giuseppe Petralia
- Dipartimento di Medicina Clinica, Sanita’ Pubblica, Scienze della Vita e dell’Ambiente, Universita’ degli Studi dell’Aquila, L’Aquila, Italy
| | - Giuseppe Aloisi
- Dipartimento di Medicina Clinica, Sanita’ Pubblica, Scienze della Vita e dell’Ambiente, Universita’ degli Studi dell’Aquila, L’Aquila, Italy
| | - Karlos Zepeda
- Touro College of Osteopathic Medicine, Department of Orthopaedics, New York, NY, USA
| | - Christian Schaller
- Südtiroler Sanitätsbetrieb, Department Orthopaedic Surgery, Brixen, Italy
| | - Pier Francesco Indelli
- Südtiroler Sanitätsbetrieb, Department Orthopaedic Surgery, Brixen, Italy
- Personalized Arthroplasty Society (PAS), Atlanta, GA, USA
- Paracelsus Medical University (PMU), Institute of Biomechanics, Salzburg, Austria
- The Breyer Center for Overseas Studies in Florence, Stanford University, Florence, Italy
- CESAT, Department of Orthopaedic Surgery, Azienda Sanitaria Toscana Centro, Fucecchio, Florence, Italy
| |
Collapse
|
9
|
Behnam YA, Anantha Krishnan A, List R, Clary CW. In Vitro Verification of Simulated Daily Activities Using Implant-Specific Kinematics from In Vivo Measurements. Bioengineering (Basel) 2024; 11:1108. [PMID: 39593768 PMCID: PMC11591298 DOI: 10.3390/bioengineering11111108] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2024] [Revised: 10/17/2024] [Accepted: 10/22/2024] [Indexed: 11/28/2024] Open
Abstract
The mechanism and boundary conditions used to drive experimental joint simulators have historically adopted standardized profiles developed from healthy, non-total knee arthroplasty (TKA) patients. The purpose of this study was to use implant-specific in vivo knee kinematics to generate physiologically relevant boundary conditions used in the evaluation of cadaveric knees post-TKA. Implant-specific boundary conditions were generated by combining in vivo fluoroscopic kinematics, musculoskeletal modeling-generated quadriceps loading, and telemetric knee compressive loading during activities of daily living (ADL) to dynamically drive a servo-hydraulic knee joint simulator. Ten cadaveric knees were implanted with the same TKA components and mounted in the knee simulator to verify the resulting load profiles against reported fluoroscopic kinematics and loading captured by an ultra-congruent telemetric knee implant. The cadaveric simulations resulted in implant-specific boundary conditions, which accurately recreate the in vivo performance of the like-implanted knee, with Root Mean Square Error (RMSE) in femoral low point kinematics below 2.0 mm across multiple activities of daily living. This study demonstrates the viability of in vivo fluoroscopy as the source of relevant boundary conditions for a novel knee loading apparatus, enabling dynamic cadaveric knee loading that aligns with clinical observations to improve the preclinical development of TKA component design.
Collapse
Affiliation(s)
- Yashar A. Behnam
- Center for Orthopaedic Biomechanics, University of Denver, Denver, CO 80210, USA; (Y.A.B.); (A.A.K.)
| | - Ahilan Anantha Krishnan
- Center for Orthopaedic Biomechanics, University of Denver, Denver, CO 80210, USA; (Y.A.B.); (A.A.K.)
| | - Renate List
- Institute for Biomechanics, ETH Zurich, 8093 Zurich, Switzerland;
- Human Performance Lab, Schulthess Clinic, 8008 Zurich, Switzerland
| | - Chadd W. Clary
- Center for Orthopaedic Biomechanics, University of Denver, Denver, CO 80210, USA; (Y.A.B.); (A.A.K.)
| |
Collapse
|
10
|
Smolle MA, Keintzel M, Staats K, Böhler C, Windhager R, Koutp A, Leithner A, Donner S, Reiner T, Renkawitz T, Sava MP, Hirschmann MT, Sadoghi P. Radiolucent lines and revision risk in total knee arthroplasty using the conventional versus the Attune S+ tibial baseplate. Bone Joint J 2024; 106-B:1240-1248. [PMID: 39481434 DOI: 10.1302/0301-620x.106b11.bjj-2024-0084.r3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/02/2024]
Abstract
Aims This multicentre retrospective observational study's aims were to investigate whether there are differences in the occurrence of radiolucent lines (RLLs) following total knee arthroplasty (TKA) between the conventional Attune baseplate and its successor, the novel Attune S+, independent from other potentially influencing factors; and whether tibial baseplate design and presence of RLLs are associated with differing risk of revision. Methods A total of 780 patients (39% male; median age 70.7 years (IQR 62.0 to 77.2)) underwent cemented TKA using the Attune Knee System) at five centres, and with the latest radiograph available for the evaluation of RLL at between six and 36 months from surgery. Univariate and multivariate logistic regression models were performed to assess associations between patient and implant-associated factors on the presence of tibial and femoral RLLs. Differences in revision risk depending on RLLs and tibial baseplate design were investigated with the log-rank test. Results The conventional and novel Attune baseplates were used in 349 (45%) and 431 (55%) patients, respectively. At a median follow-up of 14 months (IQR 11 to 25), RLLs were present in 29% (n = 228/777) and 15% (n = 116/776) of the tibial and femoral components, respectively, and were more common in the conventional compared to the novel baseplate. The novel baseplate was independently associated with a lower incidence of tibial and femoral RLLs (both regardless of age, sex, BMI, and time to radiograph). One- and three-year revision risk was 1% (95% CI 0.4% to 1.9%)and 6% (95% CI 2.6% to 13.2%), respectively. There was no difference between baseplate design and the presence of RLLs on the the risk of revision at short-term follow-up. Conclusion The overall incidence of RLLs, as well as the incidence of tibial and femoral RLLs, was lower with the novel compared to the conventional tibial Attune baseplate design, but higher than in the predecessor design and other commonly used TKA systems.
Collapse
Affiliation(s)
- Maria A Smolle
- Department of Orthopedics and Trauma, Medical University of Graz, Graz, Austria
| | - Maximilian Keintzel
- Department of Orthopedics and Trauma-Surgery, Medical University of Vienna, Vienna, Austria
| | - Kevin Staats
- Department of Orthopedics and Trauma-Surgery, Medical University of Vienna, Vienna, Austria
| | - Christoph Böhler
- Department of Orthopedics and Trauma-Surgery, Medical University of Vienna, Vienna, Austria
| | - Reinhard Windhager
- Department of Orthopedics and Trauma-Surgery, Medical University of Vienna, Vienna, Austria
| | - Amir Koutp
- Department of Orthopedics and Trauma, Medical University of Graz, Graz, Austria
| | - Andreas Leithner
- Department of Orthopedics and Trauma, Medical University of Graz, Graz, Austria
| | - Stefanie Donner
- Charite - Center for Musculosceletal Surgery, Berlin, Germany
| | - Tobias Reiner
- Department of Orthopaedics, Heidelberg University Hospital, Heidelberg, Germany
| | - Tobias Renkawitz
- Department of Orthopaedics, Heidelberg University Hospital, Heidelberg, Germany
| | - Manuel-Paul Sava
- Department of Orthopaedic Surgery and Traumatology, Kantonsspital Baselland, Bruderholz, Switzerland
| | - Michael T Hirschmann
- Department of Orthopaedic Surgery and Traumatology, Kantonsspital Baselland, Bruderholz, Switzerland
| | - Patrick Sadoghi
- Department of Orthopedics and Trauma, Medical University of Graz, Graz, Austria
| |
Collapse
|
11
|
Holthof SR, Rock M, van Arkel R, Brivio A, Barrett D, Amis AA. Evaluation of a novel robotic testing method for stability and kinematics of total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 2024. [PMID: 39445624 DOI: 10.1002/ksa.12516] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/29/2024] [Revised: 10/06/2024] [Accepted: 10/10/2024] [Indexed: 10/25/2024]
Abstract
PURPOSE This work developed a novel preclinical test of total knee replacements (TKRs) in order to explain TKR instability linked to patient dissatisfaction. It was hypothesized that stability tests on the isolated moving prostheses would provide novel comparative data on the stability and kinematics among TKR designs. METHODS Three TKR designs, DePuy Synthes Attune MS, Stryker Triathlon and Zimmer Biomet Persona MC, were assessed using a robotic arm while flexing-extending 0-140°. Tests imposed 710 N body weight combined with three tibial loads: no anterior-posterior (AP) force, 90 N anterior or 90 N posterior force. Other load effects were minimized and the kinematics was recorded. Each implant was tested six times to investigate the repeatability of the method. Data were analysed using statistical parametric mapping with one-way analysis of variance (ANOVA). If significance was found (p < 0.05), post hoc t tests with Bonferroni correction were used to contrast groups. RESULTS Significant differences were found throughout flexion-extension. Femoral rollback, AP stability, coupled internal-external rotation and AP position (roll-back) were all influenced by implant design. AP stability of the TKRs reduced with flexion reaching Attune 15 mm, Persona 13 mm and Triathlon 21 mm at 140° flexion. Tractive rolling significantly affected kinematics in the less congruent Triathlon design, with 6 mm different paths between flexion and extension motion (p < 0.05 across 5-100°). Paradoxical anterior femoral sliding in early flexion (0-40°) occurred in Persona and Triathlon designs. CONCLUSIONS The novel testing technique provides, for the first time, comparative data on the inherent stability and kinematics of the TKR implants themselves across the arc of flexion-extension, independent of variables including soft tissue behaviour and surgical technique. The data show how much each prosthesis can contribute to the stability and motion of the implanted knee. Similar data from a wider range of designs will enable more informed decisions regarding implant design choice, aiming to reduce the prevalence of TKR instability in patients. LEVEL OF EVIDENCE Controlled laboratory study.
Collapse
Affiliation(s)
- Sander R Holthof
- Biomechanics Group, Mechanical Engineering Department, Imperial College London, London, UK
| | - Mick Rock
- De Puy Synthes Ltd, Beeston, Leeds, UK
| | - Richard van Arkel
- Biomechanics Group, Mechanical Engineering Department, Imperial College London, London, UK
| | - Angela Brivio
- King Edward VII Hospital, London, UK
- Department of Trauma and Orthopaedic Surgery, Istituto Clinico Città Studi, Milano, Italy
| | - David Barrett
- King Edward VII Hospital, London, UK
- School of Engineering Sciences, University of Southampton, Southampton, UK
| | - Andrew A Amis
- Biomechanics Group, Mechanical Engineering Department, Imperial College London, London, UK
| |
Collapse
|
12
|
Lizcano JD, Giakas AM, Goh GS, Abbaszadeh A, Reddy YC, Courtney PM. Fix or Replace? Comparable Outcomes With Internal Fixation and Distal Femoral Replacement for Periprosthetic Fractures Above Total Knee Arthroplasty. J Arthroplasty 2024:S0883-5403(24)01019-2. [PMID: 39428002 DOI: 10.1016/j.arth.2024.10.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/11/2024] [Revised: 10/02/2024] [Accepted: 10/07/2024] [Indexed: 10/22/2024] Open
Abstract
BACKGROUND The optimal treatment for periprosthetic fracture (PPfx) around total knee arthroplasty (TKA) remains a topic of debate. Due to its low incidence, comparative studies analyzing arthroplasty and fixation are lacking in the literature. The purpose of this study was to compare the outcomes of distal femoral replacement (DFR) and open reduction and internal fixation open reduction internal fixation (ORIF) for distal femur PPfx. METHODS We reviewed a consecutive series of 99 patients who underwent DFR (n = 54) or ORIF (n = 45) for distal femur PPfx. The indications for DFR were reviewed. Fractures were classified based on their relation to the implant using the Su classification. The primary outcome was rerevision, while secondary endpoints included inpatient complications, mortality within the first year, and mechanical complications such as loosening and non-union. RESULTS Type 2 fractures were the most prevalent type in both groups (DFR 37 versus ORIF 48.9%), while Type 1 fractures were more commonly treated with ORIF (35.6 versus 16.7%) and Type 3 with DFR (46.3 versus 15.6%) (P = 0.003). The preferred techniques in the ORIF group were plate osteosynthesis (66.7%) and retrograde nailing (31.1%). At a mean follow-up of 4.2 years (range, one to 14.1), DFR and ORIF did not demonstrate any difference in revision rates (13 versus 24.4%, P = 0.140) or mortality (3.7 versus 4.4%, P = 0.887). However, more mechanical complications were noted in the ORIF group (22.2 versus 7.4%, P = 0.035). CONCLUSIONS Both DFR and open reduction and internal fixation have comparable revision rates, complications, and clinical outcomes when used in supracondylar periprosthetic distal femur fractures. Longer-term studies are needed to assess DFR survivorship as well as outcomes of newer trauma techniques such as nail-plate combinations.
Collapse
Affiliation(s)
- Juan D Lizcano
- Department of Orthopaedic Surgery, Rothman Orthopaedic Institute, Thomas Jefferson University Hospital, Philadelphia, Pennsylvania
| | - Alec M Giakas
- Department of Orthopaedic Surgery, Rothman Orthopaedic Institute, Thomas Jefferson University Hospital, Philadelphia, Pennsylvania
| | - Graham S Goh
- Department of Orthopaedic Surgery, Rothman Orthopaedic Institute, Thomas Jefferson University Hospital, Philadelphia, Pennsylvania
| | - Ahmad Abbaszadeh
- Department of Orthopaedic Surgery, Rothman Orthopaedic Institute, Thomas Jefferson University Hospital, Philadelphia, Pennsylvania
| | - Yashas C Reddy
- Department of Orthopaedic Surgery, Rothman Orthopaedic Institute, Thomas Jefferson University Hospital, Philadelphia, Pennsylvania
| | - Paul M Courtney
- Department of Orthopaedic Surgery, Rothman Orthopaedic Institute, Thomas Jefferson University Hospital, Philadelphia, Pennsylvania
| |
Collapse
|
13
|
Luzzi A, Lakra A, Murtaugh T, Shah RP, Cooper HJ, Geller JA. The Effect of Periprosthetic Fractures Following Total Hip and Knee Arthroplasty on Long-Term Functional Outcomes and Quality of Life. Arthroplast Today 2024; 29:101418. [PMID: 39228909 PMCID: PMC11369410 DOI: 10.1016/j.artd.2024.101418] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/25/2023] [Revised: 02/06/2024] [Accepted: 04/28/2024] [Indexed: 09/05/2024] Open
Abstract
Background Periprosthetic fractures (PPFs) after total joint arthroplasty (TJA) can be devastating, yet their long-term impact has not been well described. The aim of this study is to compare the long-term outcomes of patients who sustained a PPF about a TJA with those of patients who underwent an uncomplicated TJA. Methods Patients who sustained a PPF after primary TJA between 2005 and 2014 were identified. Seventeen patients with a minimum 2-year follow-up (PPF cohort) were compared to a matched cohort of 67 patients who underwent uncomplicated TJA. Demographic data, comorbidities, surgical details, and complications were analyzed. Quality of life and functional outcomes were assessed with 12-Item Short Form Health Survey (SF-12), Western Ontario and McMasdter Universities Arthritis Index (WOMAC), and Knee Society Function Score. Results The overall complication rate was 41.2% in the PPF group, including 3 additional fractures (17.6%), 2 wound infections (11.8%), one prosthetic joint infection (5.8%), and one painful patellar hardware necessitating removal (5.8%). At 2 years, both physical and mental components of the SF-12 were significantly lower for the PPF cohort vs control (SF-12-P, 28.7 ± 4.4 vs 40.8 ± 10.3, P < .001, SF-12-M, 36.7 ± 5.07 vs 55.0 ± 8.19, P < .0001). WOMAC pain and function scores were also significantly worse in the PPF cohort vs control at 2 years (WOMAC-pain, 38.8 ± 29.9 vs 87.4 ± 22.1; P < .0001, WOMAC-function, 40.7 ± 8.7 vs 76.1 ± 20.3; P < .0001). At 2 years, score improvements from prearthroplasty baseline were significantly greater in the control cohort vs PPF for SF-12-physical, WOMAC-pain, and WOMAC-function. Conclusions Patients who sustained PPFs following TJA have poor long-term outcomes despite appropriate treatment. These results can help counsel patients and encourage heightened efforts to minimize the risk of PPF. Level of Evidence Level III.
Collapse
Affiliation(s)
- Andrew Luzzi
- Department of Orthopedic Surgery, Columbia University Medical Center, New York, NY, USA
| | - Akshay Lakra
- Department of Orthopedic Surgery, Columbia University Medical Center, New York, NY, USA
| | - Taylor Murtaugh
- Department of Orthopedic Surgery, Columbia University Medical Center, New York, NY, USA
| | - Roshan P. Shah
- Department of Orthopedic Surgery, Columbia University Medical Center, New York, NY, USA
| | - H. John Cooper
- Department of Orthopedic Surgery, Columbia University Medical Center, New York, NY, USA
| | - Jeffrey A. Geller
- Department of Orthopedic Surgery, Columbia University Medical Center, New York, NY, USA
| |
Collapse
|
14
|
Mozella ADP, Cobra HADAB, Minamoto STN, Salim R, Leal AC. Causes of Revision of Total Knee Arthroplasties in a Tertiary Hospital in Brazil. Rev Bras Ortop 2024; 59:e696-e701. [PMID: 39649045 PMCID: PMC11624922 DOI: 10.1055/s-0042-1757304] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2022] [Accepted: 08/17/2022] [Indexed: 12/10/2024] Open
Abstract
Objective To identify the causes of revision of total knee arthroplasty in a referral center in Brazil. Methods This is a case series, with 80 patients undergoing revision surgery for total knee arthroplasty (RTKA) at a referral center for knee surgery, between August 2019 and November 2021, with a mean age of 69.6 years. Of these patients, 60.23% were female and 39.77% were male. The average body mass index (BMI) was 30.23 kg/m 2 . The causes of TKA failure were defined as: periprosthetic infection according to the 2018 International Consensus Meeting criteria, ligament instability, range of motion limitation, periprosthetic fracture, malalignment, aseptic loosening, pain due to non-replacement of the patellar cartilage, polyethylene wear, fracture of implants, insufficiency of the extensor mechanism. Results Periprosthetic joint infection (PJI) was the main cause of revision total knee arthroplasty (TKA), corresponding to 47.73% of cases. Aseptic loosening of one or more components represented the second most frequent reason for TKA failure, accounting for 35.23% of revisions. Range of motion limitation represented the third most frequent cause, accounting for 5.68% of surgeries. Instability was the fourth most frequent reason for RTKA, occurring in 4.55% of patients. The other causes of revision were: periprosthetic fracture (3.41%), failure due to rupture of the extensor mechanism (2.27%), and pain attributed to non-replacement of the patellar cartilage (1.14%). Conclusions Periprosthetic joint infection was the most frequent cause of TKA revision in our series. Other reasons for TKA failures were, in descending order: aseptic loosening, limited range of motion, and instability.
Collapse
Affiliation(s)
- Alan de Paula Mozella
- Departamento de Ortopedia e Traumatologia, Centro de Cirurgia do Joelho, Instituto Nacional de Traumatologia e Ortopedia (INTO), Rio de Janeiro, RJ, Brasil.
| | - Hugo Alexandre de Araújo Barros Cobra
- Departamento de Ortopedia e Traumatologia, Centro de Cirurgia do Joelho, Instituto Nacional de Traumatologia e Ortopedia (INTO), Rio de Janeiro, RJ, Brasil.
| | - Sandra Tie Nishibe Minamoto
- Departamento de Ortopedia e Traumatologia, Centro de Cirurgia do Joelho, Instituto Nacional de Traumatologia e Ortopedia (INTO), Rio de Janeiro, RJ, Brasil.
| | - Rodrigo Salim
- Departamento de Ortopedia e Anestesiologia, Faculdade de Medicina de Ribeirão Preto, Universidade de São Paulo (USP), São Paulo, SP, Brasil.
| | - Ana Carolina Leal
- Divisão de Ensino e Pesquisa, Instituto Nacional de Traumatologia e Ortopedia (INTO), Rio de Janeiro, RJ, Brasil.
| |
Collapse
|
15
|
Tian Y, Ahmed AG, Hiredesai AN, Huang LW, Patel AM, Ghomrawi HMK. The Cost-Effectiveness of Computer-Assisted Compared with Conventional Total Knee Arthroplasty: A Payer's Perspective. J Bone Joint Surg Am 2024; 106:1680-1687. [PMID: 38662805 DOI: 10.2106/jbjs.23.00555] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 09/21/2024]
Abstract
BACKGROUND Recent evidence showing that computer-assisted total knee arthroplasty (TKA) is associated with better outcomes compared with conventional TKA for patients with end-stage knee osteoarthritis has not been included in economic evaluations of computer-assisted TKA, which are needed to support coverage decisions. This study evaluated the cost-effectiveness of computer-assisted TKA from a payer's perspective, incorporating recent evidence. METHODS We compared computer-assisted TKA with conventional TKA with regard to costs (in 2022 U.S. dollars) and quality-adjusted life-years (QALYs) using Markov models for elderly patients (≥65 years of age) and patients who were not elderly (55 to 64 years of age). Costs and QALYs were estimated in the lifetime for elderly patients and in the short term for patients who were not elderly, under a bundled payment program and a Fee-for-Service program. Transition probabilities, costs, and QALYs were retrieved from the literature, a national knee arthroplasty registry, and the National Center for Health Statistics. Threshold and probabilistic sensitivity analyses were conducted to examine the robustness of key estimates used in the base-case analysis. Using projected estimates of TKA utilization, the total cost savings of performing computer-assisted TKA rather than conventional TKA were estimated. RESULTS Compared with conventional TKA, computer-assisted TKA was associated with higher QALYs and lower costs for both elderly patients and patients who were not elderly, regardless of payment programs, making computer-assisted TKA a favorable treatment option. Widespread adoption of computer-assisted TKA in all U.S. patients would result in an estimated total cost saving of $1 billion for payers. CONCLUSIONS Compared with conventional TKA, computer-assisted TKA reduces costs to payers while providing favorable outcomes. Payers may consider providing additional payment incentives to providers for performing computer-assisted TKA, to achieve outcome improvement and cost control by facilitating widespread adoption of computer-assisted TKA. LEVEL OF EVIDENCE Economic and Decision Analysis Level II . See Instructions for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- Yao Tian
- Department of Surgery, Feinberg School of Medicine, Northwestern University, Chicago, Illinois
- Center for Health Services and Outcomes Research, Institute for Public Health and Medicine, Feinberg School of Medicine, Northwestern University, Chicago, Illinois
| | | | - Annika N Hiredesai
- Department of Economics, Northwestern University, Evanston, Illinois
- Department of Neurobiology, Northwestern University, Evanston, Illinois
| | - Lynn Wei Huang
- Center for Health Services and Outcomes Research, Institute for Public Health and Medicine, Feinberg School of Medicine, Northwestern University, Chicago, Illinois
| | - Ankita M Patel
- Department of Medical Social Sciences, Feinberg School of Medicine, Northwestern University, Chicago, Illinois
| | - Hassan M K Ghomrawi
- Department of Surgery, Feinberg School of Medicine, Northwestern University, Chicago, Illinois
- Center for Health Services and Outcomes Research, Institute for Public Health and Medicine, Feinberg School of Medicine, Northwestern University, Chicago, Illinois
- Rheumatology Division, Department of Medicine, Feinberg School of Medicine, Northwestern University, Chicago, Illinois
- Department of Pediatrics, Feinberg School of Medicine, Northwestern University, Chicago, Illinois
| |
Collapse
|
16
|
Yee DKH, Leung JTC, Chu V, Man G, Lam GYT, Lau JKY, Choi TL, Chau WW, Ng JP, Ong MTY, Ho KKW, Yung PSH. Reliability of pre-resection ligament tension assessment in imageless robotic assisted total knee replacement. ARTHROPLASTY 2024; 6:44. [PMID: 39218949 PMCID: PMC11367864 DOI: 10.1186/s42836-024-00266-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2024] [Accepted: 06/06/2024] [Indexed: 09/04/2024] Open
Abstract
BACKGROUND Ligament tension balance is a major determinant for the success of total knee replacement (TKR). The present study aimed at determining the inter-rater and intra-rater reliability in performing ligament tension assessment using an imageless robotic-assisted TKR. METHODS Twenty-four knees in 21 patients who received robotic-assisted TKR for end-stage varus osteoarthritis were examined. Three orthopedic specialists and six orthopedic trainees participated in the operations. Data from the ligament tension assessment were collected during the operations. RESULTS For the inter-rater reliability, "extension medial" and "flexion medial" had excellent reliability whilst "extension lateral" and "flexion lateral" had good-to-excellent reliability. For the intra-rater reliability, "extension medial" showed excellent reliability, "extension lateral" and "flexion medial" showed good-to-excellent reliability, and "flexion lateral" showed moderate-to-excellent reliability. CONCLUSIONS Robotic-assisted technology provides a reliable solution to improve ligament tension assessment. All ligament tension assessments with the use of the technology could demonstrate at least good-to-excellent reliability except for the intra-rater reliability of "flexion lateral".
Collapse
Affiliation(s)
- Dennis K H Yee
- Department of Orthopaedics & Traumatology, Alice Ho Miu Ling Nethersole Hospital, Hong Kong SAR, China
| | - Jonathan T C Leung
- Department of Orthopaedics & Traumatology, Alice Ho Miu Ling Nethersole Hospital, Hong Kong SAR, China
| | - Vikki Chu
- Department of Orthopaedics & Traumatology, Alice Ho Miu Ling Nethersole Hospital, Hong Kong SAR, China
| | - Gene Man
- Office of Research and Knowledge Transfer Services, Chinese University of Hong Kong, Hong Kong SAR, China
| | - Gloria Y T Lam
- Department of Orthopaedics & Traumatology, Alice Ho Miu Ling Nethersole Hospital, Hong Kong SAR, China
| | - Jimmy K Y Lau
- Department of Orthopaedics & Traumatology, Alice Ho Miu Ling Nethersole Hospital, Hong Kong SAR, China
| | - Tsz-Lung Choi
- Department of Orthopaedics & Traumatology, Alice Ho Miu Ling Nethersole Hospital, Hong Kong SAR, China
| | - Wai-Wang Chau
- Department of Orthopaedics and Traumatology, Chinese University of Hong Kong, Hong Kong SAR, China
| | - Jonathan Patrick Ng
- Department of Orthopaedics and Traumatology, Prince of Wales Hospital, Hong Kong SAR, China
| | - Michael Tim-Yun Ong
- Department of Orthopaedics and Traumatology, Chinese University of Hong Kong, Hong Kong SAR, China.
| | - Kevin Ki-Wai Ho
- Department of Orthopaedics and Traumatology, CUHK Medical Centre, Hong Kong SAR, China
| | - Patrick Shu-Hang Yung
- Department of Orthopaedics and Traumatology, Chinese University of Hong Kong, Hong Kong SAR, China
| |
Collapse
|
17
|
Bundschuh KE, Muffly BT, Ayeni AM, Heo KY, Khawaja SR, Tocio AJ, Karzon AL, Premkumar A, Guild GN. Should All Patients Receive Extended Oral Antibiotic Prophylaxis? Defining Its Role in Patients Undergoing Primary and Aseptic Revision Total Joint Arthroplasty. J Arthroplasty 2024; 39:S117-S121.e4. [PMID: 38218558 DOI: 10.1016/j.arth.2024.01.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/01/2023] [Revised: 12/28/2023] [Accepted: 01/07/2024] [Indexed: 01/15/2024] Open
Abstract
BACKGROUND Prior studies have demonstrated reduced periprosthetic joint infection (PJI) rates following extended oral antibiotics (EOAs) for high-risk patients undergoing primary total joint arthroplasty (TJA). This study compared 3-month PJI rates in all patients undergoing primary or aseptic revision TJA with or without EOA prophylaxis. METHODS In total, 2,982 consecutive primary (n = 2,677) and aseptic revision (n = 305) TJAs were performed by a single, fellowship-trained arthroplasty surgeon from 2016 to 2022 were retrospectively reviewed. Beginning January 2020, all patients received 7 days of 300 mg oral cefdinir twice daily immediately postoperatively. Rates of PJI at 3 months were compared between patients who received or did not receive EOA. RESULTS Rates of PJI at 3 months in patients undergoing primary and aseptic revision TJA were significantly lower in those receiving EOA prophylaxis compared to those who did not (0.41 versus 1.13%, respectively; P = .02). After primary TJA, lower PJI rates were observed with EOA prophylaxis utilization (0.23 versus 0.74%, P = .04; odds ratio [OR] 3.85). Following aseptic revision TJA, PJI rates trended toward a significant decrease with the EOA compared to without (1.88 versus 4.83%, respectively; P = .16; OR 2.71). CONCLUSIONS All patients undergoing primary or aseptic revision TJA who received EOA prophylaxis were 3.85 and 2.71 times less likely, respectively, to develop PJI at 3 months compared to those without EOA. Future studies are needed to determine if these results are maintained at postoperative time periods beyond 3 months following primary TJA. LEVEL OF EVIDENCE III, Retrospective review.
Collapse
Affiliation(s)
- Kyle E Bundschuh
- Department of Orthopaedic Surgery, Investigation performed at Emory University, Atlanta, Georgia
| | - Brian T Muffly
- Department of Orthopaedic Surgery, Investigation performed at Emory University, Atlanta, Georgia
| | - Ayomide M Ayeni
- Department of Orthopaedic Surgery, Investigation performed at Emory University, Atlanta, Georgia
| | - Kevin Y Heo
- Department of Orthopaedic Surgery, Investigation performed at Emory University, Atlanta, Georgia
| | - Sameer R Khawaja
- Department of Orthopaedic Surgery, Investigation performed at Emory University, Atlanta, Georgia
| | - Adam J Tocio
- Department of Orthopaedic Surgery, Investigation performed at Emory University, Atlanta, Georgia
| | - Anthony L Karzon
- Department of Orthopaedic Surgery, Investigation performed at Emory University, Atlanta, Georgia
| | - Ajay Premkumar
- Department of Orthopaedic Surgery, Investigation performed at Emory University, Atlanta, Georgia
| | - George N Guild
- Department of Orthopaedic Surgery, Investigation performed at Emory University, Atlanta, Georgia
| |
Collapse
|
18
|
Luo TD, Sogbein OA, MacDonald BM, Masse JA, Willing RT, Lanting BA. Central cone design demonstrates greater micromotion compared to keel design in cementless tibial baseplates: A biomechanical analysis. Knee Surg Sports Traumatol Arthrosc 2024; 32:2267-2276. [PMID: 38713877 DOI: 10.1002/ksa.12224] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/25/2024] [Revised: 04/19/2024] [Accepted: 04/20/2024] [Indexed: 05/09/2024]
Abstract
PURPOSE The purpose of this study was to compare micromotion of two new cementless tibial baseplates to a cementless design with well-published clinical success. METHODS Three cementless tibial baseplate designs (fixed-bearing [FB] with keel and cruciform pegs, rotating-platform with porous central cone and pegs, FB with cruciform keel and scalloped pegs) were evaluated on sawbone models. Loading was applied to the baseplate at a rate of 1 Hz for 10,000 cycles, which represents 6-8 weeks of stair descent. This time frame also represents the approximate time length for the induction of biologic fixation of cementless implants. Compressive and shear micromotion at the sawbone-implant interface were measured. RESULTS At the end of the loading protocol, the central cone rotating-platform design exhibited greater micromotion at the anterior (p < 0.001), posterior (p < 0.001) and medial locations (p = 0.049) compared to the other two implants. The central cone design also exhibited greater translational micromotion in the sagittal plane at the medial (p = 0.001) and lateral locations (p = 0.034) and in the coronal plane anteriorly (p = 0.007). CONCLUSION The cementless central cone rotating-platform baseplate demonstrated greater vertical and translational micromotion compared to the two FB baseplates with a keel underloading. This may indicate lower initial mechanical stability in implants without a keel, which possibly affects osseointegration. The implication of this is yet unknown and requires further long-term clinical follow-up to correlate these laboratory findings. LEVEL OF EVIDENCE V (biomechanical study).
Collapse
Affiliation(s)
- T David Luo
- Department of Orthopaedic Surgery, London Health Sciences Centre, University Hospital, London, Ontario, Canada
- Orthopaedics Northeast, Fort Wayne, Indiana, USA
| | - Olawale A Sogbein
- Department of Orthopaedic Surgery, London Health Sciences Centre, University Hospital, London, Ontario, Canada
| | - Brett M MacDonald
- Department of Mechanical & Materials Engineering, University of Western Ontario, London, Ontario, Canada
| | - Jarrett A Masse
- Department of Mechanical & Materials Engineering, University of Western Ontario, London, Ontario, Canada
| | - Ryan T Willing
- Department of Mechanical & Materials Engineering, University of Western Ontario, London, Ontario, Canada
| | - Brent A Lanting
- Department of Orthopaedic Surgery, London Health Sciences Centre, University Hospital, London, Ontario, Canada
| |
Collapse
|
19
|
Muffly BT, Ayeni AM, Bonsu JM, Heo K, Premkumar A, Guild GN. Early Versus Late Periprosthetic Joint Infection After Total Knee Arthroplasty: Do Patient Differences Exist? J Arthroplasty 2024; 39:S429-S435.e4. [PMID: 38677341 DOI: 10.1016/j.arth.2024.04.061] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/25/2023] [Revised: 04/17/2024] [Accepted: 04/18/2024] [Indexed: 04/29/2024] Open
Abstract
BACKGROUND Periprosthetic joint infection (PJI) is a devastating complication following total knee arthroplasty (TKA). Little evidence exists comparing those with early versus late PJI. The purpose of the study was to determine comorbidity profile differences between patients developing early and late PJI. METHODS There were 72,659 patients undergoing primary TKA from 2009 to 2021, who were identified from a commercial claims and encounters database. Subjects diagnosed with PJI were categorized as either 'early' (within 90 days of index procedure) or 'late' (> 2 years after index arthroplasty). Non-infected patients within these periods served as control groups following 4:1 propensity score matching on other extraneous variables. Logistic regression analyses were performed comparing comorbidities between groups. RESULTS Patients were significantly younger in the late compared to the early infection group (58.1 versus 62.4 years, P < .001). When compared to those with early PJI, patients who had chronic kidney disease (13.3 versus 4.1%; OR [odds ratio] 5.17, P = .002), malignancy (20.4 versus 10.5%; OR 2.53, P = .009), uncomplicated diabetes (40.8 versus 30.6%; OR 2.00, P = .01), rheumatoid arthritis (9.2 versus 3.3%; OR 2.66, P = .046), and hypertension (88.8 versus 81.6%; OR 2.17, P = .04), were all significant predictors of developing a late PJI. CONCLUSIONS When compared to patients diagnosed with early PJI following primary TKA, the presence of chronic kidney disease, malignancy, uncomplicated diabetes, rheumatoid arthritis, and hypertension, were independent risk factors for the development of late PJI. Younger patients who have these comorbidities may be targets for preoperative optimization interventions that minimize the risk of PJI.
Collapse
Affiliation(s)
- Brian T Muffly
- Department of Orthopaedic Surgery, Emory University School of Medicine, Atlanta, Georgia
| | - Ayomide M Ayeni
- Department of Orthopaedic Surgery, Emory University School of Medicine, Atlanta, Georgia
| | - Janice M Bonsu
- Department of Orthopaedic Surgery, Emory University School of Medicine, Atlanta, Georgia
| | - Kevin Heo
- Department of Orthopaedic Surgery, Emory University School of Medicine, Atlanta, Georgia
| | - Ajay Premkumar
- Department of Orthopaedic Surgery, Emory University School of Medicine, Atlanta, Georgia
| | - George N Guild
- Department of Orthopaedic Surgery, Emory University School of Medicine, Atlanta, Georgia
| |
Collapse
|
20
|
Konopitski AP, Jones H, Mathis KB, Noble PC, Rodriguez-Quintana D. Wearing a Surgical Vest With a Sterile Surgical Helmet System Decreases Contamination of the Surgical Field. J Arthroplasty 2024; 39:2377-2382. [PMID: 38679349 DOI: 10.1016/j.arth.2024.04.066] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/14/2023] [Revised: 04/18/2024] [Accepted: 04/19/2024] [Indexed: 05/01/2024] Open
Abstract
BACKGROUND Sterile surgical helmet systems are frequently utilized in total knee arthroplasty procedures to protect the surgeon while maintaining a comfortable working environment. However, common helmet systems pressurize the space between the surgical gown and the surgeon's skin. In gowns with a back seam, this may allow contaminated skin particles to escape into the surgical field. By measuring bacterial colony-forming units (CFUs), this study sought to determine if occlusion of the open back seam reduced the risk of potential contamination. METHODS First, qualitative analysis depicting airflow variations between gown configurations was performed using the Schlieren Spherical Mirror imaging system. Each gown configuration consisted of a sterile surgical helmet and one of 3 gown configurations: a standard gown with rear-tied closure, a standard gown with a surgical vest, and a zippered Toga-style gown. Next, a surgeon then performed simulated surgical activities for 60 minutes within a 1.4 m3 isolation chamber with work surfaces and controllable filtered air exchanges. During each procedure, contaminated particles were collected on sets of agar settle plates positioned directly behind the surgeon. Upon completion, the agar plates were incubated in a biolab, and the number of bacterial and fungal CFUs was counted. The experimental procedure was repeated 12 times for each gown configuration, with sterilization of the chamber between runs. Contamination rates were expressed as CFUs/m2/h. RESULTS The mean contamination rate measured with the standard gown was 331.7 ± 52.0 CFU/m2/h. After the addition of a surgical vest, this rate decreased by 45% to 182.2 ± 30.8 CFU/m2/h (P = .02). Similarly, with the Toga-style gown, contamination rates dropped by 49% to 170.5 ± 41.9 CFU/m2/h (P = .01). CONCLUSIONS When used in conjunction with surgical helmet systems, conventional surgical gowns do not prevent potential contamination of the surgical field. We recommend that staff within the surgical field cover the back seam of standard gowns with a vest or don a zippered Toga-style gown.
Collapse
Affiliation(s)
- Andrew P Konopitski
- Department of Orthopaedic Surgery, St. Luke's University Health Network, Bethlehem, Pennsylvania
| | - Hugh Jones
- Department of Orthopaedic Surgery, McGovern School of Medicine, UTHealth Houston, Bellaire, Texas
| | - Kenneth B Mathis
- Department of Orthopaedic Surgery, McGovern School of Medicine, UTHealth Houston, Bellaire, Texas
| | - Philip C Noble
- Department of Orthopaedic Surgery, McGovern School of Medicine, UTHealth Houston, Bellaire, Texas
| | - David Rodriguez-Quintana
- Department of Orthopaedic Surgery, McGovern School of Medicine, UTHealth Houston, Bellaire, Texas
| |
Collapse
|
21
|
van de Graaf VA, Shen TS, Wood JA, Chen DB, MacDessi SJ. Addressing sagittal plane imbalance in primary total knee arthroplasty. Bone Jt Open 2024; 5:681-687. [PMID: 39155644 PMCID: PMC11331267 DOI: 10.1302/2633-1462.58.bjo-2024-0040.r1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 08/20/2024] Open
Abstract
Aims Sagittal plane imbalance (SPI), or asymmetry between extension and flexion gaps, is an important issue in total knee arthroplasty (TKA). The purpose of this study was to compare SPI between kinematic alignment (KA), mechanical alignment (MA), and functional alignment (FA) strategies. Methods In 137 robotic-assisted TKAs, extension and flexion stressed gap laxities and bone resections were measured. The primary outcome was the proportion and magnitude of medial and lateral SPI (gap differential > 2.0 mm) for KA, MA, and FA. Secondary outcomes were the proportion of knees with severe (> 4.0 mm) SPI, and resection thicknesses for each technique, with KA as reference. Results FA showed significantly lower rates of medial and lateral SPI (2.9% and 2.2%) compared to KA (45.3%; p < 0.001, and 25.5%; p < 0.001) and compared to MA (52.6%; p < 0.001 and 29.9%; p < 0.001). There was no difference in medial and lateral SPI between KA and MA (p = 0.228 and p = 0.417, respectively). FA showed significantly lower rates of severe medial and lateral SPI (0 and 0%) compared to KA (8.0%; p < 0.001 and 7.3%; p = 0.001) and compared to MA (10.2%; p < 0.001 and 4.4%; p = 0.013). There was no difference in severe medial and lateral SPI between KA and MA (p = 0.527 and p = 0.307, respectively). MA resulted in thinner resections than KA in medial extension (mean difference (MD) 1.4 mm, SD 1.9; p < 0.001), medial flexion (MD 1.5 mm, SD 1.8; p < 0.001), and lateral extension (MD 1.1 mm, SD 1.9; p < 0.001). FA resulted in thinner resections than KA in medial extension (MD 1.6 mm, SD 1.4; p < 0.001) and lateral extension (MD 2.0 mm, SD 1.6; p < 0.001), but in thicker medial flexion resections (MD 0.8 mm, SD 1.4; p < 0.001). Conclusion Mechanical and kinematic alignment (measured resection techniques) result in high rates of SPI. Pre-resection angular and translational adjustments with functional alignment, with typically smaller distal than posterior femoral resection, address this issue.
Collapse
Affiliation(s)
- Victor A. van de Graaf
- Sydney Knee Specialists, Kogarah, Australia
- Department of Orthopaedic Surgery, Bergman Clinics, Rijswijk, Netherlands
| | - Tony S. Shen
- Adult Reconstruction and Joint Replacement Service, Hospital for Special Surgery, New York, New York, USA
| | | | - Darren B. Chen
- Sydney Knee Specialists, Kogarah, Australia
- St George Private Hospital, Kogarah, Australia
| | - Samuel J. MacDessi
- Sydney Knee Specialists, Kogarah, Australia
- St George Private Hospital, Kogarah, Australia
- School of Clinical Medicine, University of New South Wales, Sydney, Australia
| |
Collapse
|
22
|
van Duren BH, France J, Berber R, Matar HE, James PJ, Bloch BV. Is there an increased revision rate due to early tibial component loosening with a modern total knee arthroplasty design? A retrospective analysis from a large volume arthroplasty centre. ARTHROPLASTY 2024; 6:46. [PMID: 39095924 PMCID: PMC11297728 DOI: 10.1186/s42836-024-00264-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2024] [Accepted: 05/21/2024] [Indexed: 08/04/2024] Open
Abstract
BACKGROUND The Attune TKR was introduced in 2011 as a successor to its predicate design The PFC Sigma. However, following reports of early failures, there are ongoing concerns related to increased loosening rates. Given the concerns, this study aimed to compare revision rates of the Attune implant to an established predicate, and other implant designs used in a high-volume arthroplasty center. METHODS We identified 10,202 patients who underwent primary cemented TKR at our institution with a minimum of 1 year follow-up, involving 2406 Attune TKR (557 S +), 4642 PFC TKR, 3154 other designs. Primary outcomes were revision for all-causes, aseptic loosening of any component, and aseptic tibial loosening. Kaplan-Meier survival and Cox regression models were used to compare groups. Matched cohorts were selected for radiographic analysis. RESULTS 308 knees were revised. The Attune cohort had the lowest risk of revision, with a rate of 2.98 per 1000 implant-years while the PFC and All Other Implant groups had a rate of 3.15 and 4.4 respectively. Aseptic loosing was the most common cause for revision, with 76% (65/88) involving the tibia. Survival analysis showed no significant differences between the Attune and other cohorts. Radiolucent lines were detected in 7.1% of the Attune S + group, 6.8% of the standard Attune group, and 6.3% of the PFC group, with no significant differences found between them. CONCLUSION This study represents the largest non-registry review of the Attune TKR in comparison to a predicate and other designs. There was no significant increased revision rate for all-cause revision or aseptic loosening, or peri-implant radiolucencies. It appears that increased loosening may not be as concerning as originally thought. LEVEL OF EVIDENCE Level III.
Collapse
Affiliation(s)
- Bernard H van Duren
- Nottingham Elective Orthopaedic Services, Nottingham University Hospitals NHS Trust, Nottingham, NG5 1PB, UK.
- Leeds Orthopaedic and Trauma Sciences, Leeds Institute of Rheumatic and Musculoskeletal Medicine, University of Leeds, Leeds, LS2 9JT, UK.
| | - Jonathan France
- Nottingham Elective Orthopaedic Services, Nottingham University Hospitals NHS Trust, Nottingham, NG5 1PB, UK
| | - Reshid Berber
- Nottingham Elective Orthopaedic Services, Nottingham University Hospitals NHS Trust, Nottingham, NG5 1PB, UK
| | - Hosam E Matar
- Nottingham Elective Orthopaedic Services, Nottingham University Hospitals NHS Trust, Nottingham, NG5 1PB, UK
| | - Peter J James
- Nottingham Elective Orthopaedic Services, Nottingham University Hospitals NHS Trust, Nottingham, NG5 1PB, UK
| | - Benjamin V Bloch
- Nottingham Elective Orthopaedic Services, Nottingham University Hospitals NHS Trust, Nottingham, NG5 1PB, UK
- University of Nottingham, School of Medicine, Nottingham, UK
| |
Collapse
|
23
|
Borsinger TM, Quevedo Gonzalez FJ, Pagan CA, Karasavvidis T, Sculco PK, Wright TM, Kahlenberg CA, Lipman JD, Debbi EM, Vigdorchik JM, Mayman DJ. Is Tibial Bone Mineral Density Related to Sex, Age, Preoperative Alignment, or Fixation Method in Primary Total Knee Arthroplasty? J Arthroplasty 2024; 39:S108-S114. [PMID: 38548236 DOI: 10.1016/j.arth.2024.03.056] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/15/2023] [Revised: 03/18/2024] [Accepted: 03/20/2024] [Indexed: 04/23/2024] Open
Abstract
BACKGROUND Cementless total knee arthroplasty (TKA) has regained interest for its potential for long-term biologic fixation. The density of the bone is related to its ability to resist static and cyclic loading and can affect long-term implant fixation; however, little is known about the density distribution of periarticular bone in TKA patients. Thus, we sought to characterize the bone mineral density (BMD) of the proximal tibia in TKA patients. METHODS We included 42 women and 50 men (mean age 63 years, range: 50 to 87; mean body mass index 31.6, range: 20.5 to 49.1) who underwent robotic-assisted TKA and had preoperative computed tomography scans with a BMD calibration phantom. Using the robotic surgical plan, we computed the BMD distribution at 1 mm-spaced cross-sections parallel to the tibial cut from 2 mm above the cut to 10 mm below. The BMD was analyzed with respect to patient sex, age, preoperative alignment, and type of fixation. RESULTS The BMD decreased from proximal to distal. The greatest changes occurred within ± 2 mm of the tibial cut. Age did not affect BMD for men; however, women between 60 and 70 years had higher BMD than women ≥ 70 years for the total cut (P = .03) and the medial half of the cut (P = .03). Cemented implants were used in 1 86-year-old man and 18 women (seven < 60 years, seven 60 to 70 years, and four ≥ 70 year old). We found only BMD differences between cemented or cementless fixation for women < 60 years. CONCLUSIONS To our knowledge, this is the first study to characterize the preoperative BMD distribution in TKA patients relative to the intraoperative tibial cut. Our results indicate that while sex and age may be useful surrogates of BMD, the clinically relevant thresholds for cementless knees remain unclear, offering an area for future studies.
Collapse
Affiliation(s)
- Tracy M Borsinger
- Adult Reconstruction and Joint Replacement Service, Hospital for Special Surgery, New York, New York
| | | | - Cale A Pagan
- Adult Reconstruction and Joint Replacement Service, Hospital for Special Surgery, New York, New York
| | - Theofilos Karasavvidis
- Adult Reconstruction and Joint Replacement Service, Hospital for Special Surgery, New York, New York
| | - Peter K Sculco
- Adult Reconstruction and Joint Replacement Service, Hospital for Special Surgery, New York, New York
| | - Timothy M Wright
- Department of Biomechanics, Hospital for Special Surgery, New York, New York
| | - Cynthia A Kahlenberg
- Adult Reconstruction and Joint Replacement Service, Hospital for Special Surgery, New York, New York
| | - Joseph D Lipman
- Department of Biomechanics, Hospital for Special Surgery, New York, New York
| | - Eytan M Debbi
- Adult Reconstruction and Joint Replacement Service, Hospital for Special Surgery, New York, New York
| | - Jonathan M Vigdorchik
- Adult Reconstruction and Joint Replacement Service, Hospital for Special Surgery, New York, New York
| | - David J Mayman
- Adult Reconstruction and Joint Replacement Service, Hospital for Special Surgery, New York, New York
| |
Collapse
|
24
|
Ailaney N, Barra MF, Schloemann DT, Thirukumaran CP, Kaplan NB. Short-Term (6 Months or Less) Pain in Cemented versus Cementless Total Knee Arthroplasty: A Systematic Review and Meta-Analysis. J Arthroplasty 2024; 39:2137-2146. [PMID: 38387768 DOI: 10.1016/j.arth.2024.02.033] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/02/2023] [Revised: 02/11/2024] [Accepted: 02/13/2024] [Indexed: 02/24/2024] Open
Abstract
BACKGROUND Cementless total knee arthroplasty (TKA) has increased in popularity to potentially improve survivorship. Radiostereometric studies demonstrate increased component migration during the first 3 to 6 months in cementless constructs, generating concern for increased postoperative pain during early osseointegration. The purpose of this study was to evaluate short-term (≤ 6 months) pain and function in cemented versus cementless TKA. We hypothesized that cementless TKA patients report increased pain during the short-term (≤ 6 months) postoperative period. METHODS The MEDLINE, EMBASE, CINAHL, and Cochrane Libraries were searched for studies evaluating short-term (≤ 6 months) outcomes of cemented versus cementless primary TKA. Studies involving hybrid fixation were excluded. A meta-analysis was performed using standardized mean difference for primary outcomes (early postoperative pain) and weighted mean difference (WMD) for secondary outcomes (early postoperative function). RESULTS There were eleven studies included. There was no significant difference in acute postoperative pain between cemented and cementless TKA within 6 months of index TKA (standardized mean difference 0.08 in favor of cemented TKA; P = .10). Early postoperative forgotten joint scores (WMD 0.81; P = .81) and knee injury and osteoarthritis outcome scores for joint replacement (WMD 0.80 in favor of cemented TKA; P = .14) were also similar between groups. CONCLUSIONS There is no difference in short-term (≤ 6 months) pain or early function between patients receiving cemented and cementless TKA. This suggests that surgeons may utilize cementless TKA without fear of increased pain due to micromotion within 6 months of index arthroplasty. However, additional studies with uniform assessment methods are needed to further inform differences in short-term pain and early functional outcomes between cemented and cementless TKA.
Collapse
Affiliation(s)
- Nikhil Ailaney
- Department of Orthopaedic Surgery, University of Rochester Medical Center, Rochester, New York
| | - Matthew F Barra
- Department of Orthopaedic Surgery, University of Rochester Medical Center, Rochester, New York
| | - Derek T Schloemann
- Department of Orthopaedic Surgery, University of Rochester Medical Center, Rochester, New York
| | - Caroline P Thirukumaran
- Department of Orthopaedic Surgery, University of Rochester Medical Center, Rochester, New York
| | - Nathan B Kaplan
- Department of Orthopaedic Surgery, University of Rochester Medical Center, Rochester, New York
| |
Collapse
|
25
|
Bourdier JA, Bouché PA, Descamps J, Bizot P, Nizard R, Odri GA. The use of a tibial stem in primary total knee arthroplasty for patients with a frontal deformity of more than ten degrees reduces the rate of postoperative pain. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY & TRAUMATOLOGY : ORTHOPEDIE TRAUMATOLOGIE 2024; 34:3233-3240. [PMID: 39096419 DOI: 10.1007/s00590-024-04052-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/05/2024] [Accepted: 07/21/2024] [Indexed: 08/05/2024]
Abstract
BACKGROUND The use of a tibial stem for large deformities (> 10°) would reduce the incidence of pain. The aim of this study was to compare the effect of tibial stem on postoperative pain and aseptic loosening at the tibia in patients with a preoperative deformity > 10° in the frontal plane at 2 years follow-up. METHODS This was a retrospective single-center case-control study. Ninety-eight patients with deformities greater than 10° in the frontal plane and a BMI > 30 kg/m2 who had undergone posterior-stabilized (PS) total knee arthroplasty (TKA) with a tibial stem were matched using a propensity score to 98 patients who had undergone PS TKA without a tibial stem. The primary endpoint was the pain rate at 2 years. The secondary endpoints were the rate of aseptic loosening of the tibia at 2 years post-operatively. RESULTS A significant difference was found in the rate of postoperative pain at 2 years. It was higher in the group without tibial stem compared with the group with tibial stem (41.8% vs 17.3%, p = 0.0003). In the group without tibial stem, 24.4% of pain was mild, 61% moderate and no severe pain. In the tibial stem group, 47.1% of pain was mild, 41.2% moderate and no severe pain. A radiolucent line (RLL) was present at 2 years in 26.5% of prostheses in the without tibial stem group and in 9.2% of prostheses in the tibial stem group (p = 0.002). There was no difference between the two groups in terms of aseptic loosening. CONCLUSION The use of a tibial stem in primary TKA in patients with frontal deformities greater than 10° reduces postoperative pain and the presence of radiolucent lines.
Collapse
Affiliation(s)
- Jean-Arthur Bourdier
- Service de Chirurgie Orthopédique et Traumatologique, Hôpital Lariboisière, 2 rue Ambroise Paré, 75010, Paris, France
| | - Pierre-Alban Bouché
- Service de Chirurgie Orthopédique et Traumatologique, Hôpital Lariboisière, 2 rue Ambroise Paré, 75010, Paris, France.
| | - Jules Descamps
- Service de Chirurgie Orthopédique et Traumatologique, Hôpital Lariboisière, 2 rue Ambroise Paré, 75010, Paris, France
| | - Pascal Bizot
- Service de Chirurgie Orthopédique et Traumatologique, Hôpital Lariboisière, 2 rue Ambroise Paré, 75010, Paris, France
| | - Rémy Nizard
- Service de Chirurgie Orthopédique et Traumatologique, Hôpital Lariboisière, 2 rue Ambroise Paré, 75010, Paris, France
| | - Guillaume-A Odri
- Service de Chirurgie Orthopédique et Traumatologique, Hôpital Lariboisière, 2 rue Ambroise Paré, 75010, Paris, France
| |
Collapse
|
26
|
Manzetti M, Digennaro V, Di Martino A, Bordini B, Benvenuti L, Ferri R, Cecchin D, Faldini C. Survivorship of total knee arthroplasty in poliomyelitis patients: long-term results from the R.I.P.O. registry and single-institution retrospective study. Arch Orthop Trauma Surg 2024; 144:3641-3648. [PMID: 39069565 PMCID: PMC11417051 DOI: 10.1007/s00402-024-05426-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/30/2023] [Accepted: 06/26/2024] [Indexed: 07/30/2024]
Abstract
INTRODUCTION The survival of total knee arthroplasty (TKA) in patients with poliomyelitis remains a debated topic due to the high recurrence of postoperative genu recurvatum. This study aims to report the long-term survival of TKA in patients with poliomyelitis, using data from the Italian Register of Prosthetic Implantology. MATERIALS AND METHODS A registry-based population study was conducted, utilizing data from the Emilia Romagna orthopedic arthroplasty implants registry (RIPO - Registro Implantologia Protesica Ortopedica). The cohort consisted of 71 patients with poliomyelitis-related arthritis who underwent TKA. The study assessed and analyzed demographic data, implant type, fixation method, insert type, and level of constraint. Additionally, variations in preoperative and postoperative both clinical and functional Knee Society Scores (KSS) were collected. RESULTS Eight implants required revision surgery (16%), and three patients died (6.1%), resulting in a 10-year survival rate of 86.6% and a 15-year survival rate of 53.9%. Aseptic loosening was the primary cause of revision, accounting for 37.5% of failures, followed by insert wear (25%). No statistically significant correlation was found between the level of constraint and implant survival (p=0.0887, log-rank). Both the clinical and functional KSS improved postoperatively. CONCLUSION TKA is a viable alternative to knee arthrodesis and, in properly selected patients, might represent the first-choice treatment for articular degeneration due to its high survivorship. Despite the complexity of these cases, TKA can effectively alleviate articular pain, instability, and angular deviation, thereby preserving knee functionality.
Collapse
Affiliation(s)
- Marco Manzetti
- IRCCS - Istituto Ortopedico Rizzoli, Bologna, 40136, Italy.
- Department of Biomedical and Neuromotor Science-DIBINEM, University of Bologna, Bologna, Italy.
| | - V Digennaro
- IRCCS - Istituto Ortopedico Rizzoli, Bologna, 40136, Italy
| | - A Di Martino
- IRCCS - Istituto Ortopedico Rizzoli, Bologna, 40136, Italy
- Department of Biomedical and Neuromotor Science-DIBINEM, University of Bologna, Bologna, Italy
| | - B Bordini
- Laboratorio di Tecnologia Medica, IRCCS Istituto Ortopedico Rizzoli, Via Giulio Cesare Pupilli, 1, Bologna, 40136, Italy
| | - L Benvenuti
- IRCCS - Istituto Ortopedico Rizzoli, Bologna, 40136, Italy
| | - R Ferri
- IRCCS - Istituto Ortopedico Rizzoli, Bologna, 40136, Italy
| | - D Cecchin
- IRCCS - Istituto Ortopedico Rizzoli, Bologna, 40136, Italy
| | - C Faldini
- IRCCS - Istituto Ortopedico Rizzoli, Bologna, 40136, Italy
- Department of Biomedical and Neuromotor Science-DIBINEM, University of Bologna, Bologna, Italy
| |
Collapse
|
27
|
Rudolph F, Brand AG, Osterhoff G, Kleber C, Roth A, Fakler JKM. Retrograde intramedullary nail fixation with oblique fixed angle screws versus locking plates in periprosthetic supracondylar fractures after total knee arthroplasty. Eur J Trauma Emerg Surg 2024; 50:1911-1920. [PMID: 38806687 PMCID: PMC11458706 DOI: 10.1007/s00068-024-02530-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2024] [Accepted: 04/19/2024] [Indexed: 05/30/2024]
Abstract
PURPOSE Common surgical procedures in the treatment of periprosthetic distal femur fractures (PPFF) include osteosynthesis with fixed angle locking plates (LP) and retrograde intramedullary nails (RIN). This study aimed to compare LPs to RINs with oblique fixed angle screws in terms of complications, radiographic results and functional outcome. METHODS 63 PPFF in 59 patients who underwent treatment in between 2009 and 2020 were included and retrospectively reviewed. The anatomic lateral and posterior distal femoral angle (aLDFA and aPDFA) were measured on post-surgery radiographs. The Fracture Mobility Score (FMS) pre- and post-surgery, information about perceived instability in the operated leg and the level of pain were obtained via a questionnaire and previous follow-up (FU) examinations in 30 patients (32 fractures). RESULTS The collective (median age: 78 years) included 22 fractures treated with a RIN and 41 fractures fixed with a LP. There was no difference in the occurrence of complications (median FU: 21.5 months) however the rate of implant failures requiring an implant replacement was higher in fractures treated with a LP (p = 0.043). The aPDFA was greater in fractures treated with a RIN (p = 0.04). The functional outcome was comparable between both groups (median FU: 24.5 months) with a lower outcome in the post-surgery FMS (p = < 0.001). CONCLUSION Fractures treated with RIN resulted in an increased recurvation of the femur however the rate of complications and the functional outcome were comparable between the groups. The need for implant replacements following complications was higher in the LP group.
Collapse
Affiliation(s)
- Franziska Rudolph
- Department of Orthopedic, Trauma and Plastic Surgery, University Hospital of Leipzig, Liebigstr. 20, 04103, Leipzig, Germany.
- Department of Traumatology, University Hospital of Zurich, Rämistrasse 100, 8091, Zurich, Switzerland.
| | - Alexander G Brand
- Department of Orthopedic, Trauma and Plastic Surgery, University Hospital of Leipzig, Liebigstr. 20, 04103, Leipzig, Germany
| | - Georg Osterhoff
- Department of Orthopedic, Trauma and Plastic Surgery, University Hospital of Leipzig, Liebigstr. 20, 04103, Leipzig, Germany
| | - Christian Kleber
- Department of Orthopedic, Trauma and Plastic Surgery, University Hospital of Leipzig, Liebigstr. 20, 04103, Leipzig, Germany
| | - Andreas Roth
- Department of Orthopedic, Trauma and Plastic Surgery, University Hospital of Leipzig, Liebigstr. 20, 04103, Leipzig, Germany
| | - Johannes K M Fakler
- Department of Orthopedic, Trauma and Plastic Surgery, University Hospital of Leipzig, Liebigstr. 20, 04103, Leipzig, Germany
- Department of Trauma-, Hand-, Reconstructive- and Spine Surgery, Hospital of Passau, Innstraße 76, 94032, Passau, Germany
| |
Collapse
|
28
|
Kleeman-Forsthuber LT, Owens JM, Johnson RM, Clary CW, Elkins JM, Dennis DA. Clinical and Computational Evaluation of an Anatomic Patellar Component. J Arthroplasty 2024; 39:S70-S79. [PMID: 38735546 DOI: 10.1016/j.arth.2024.05.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/13/2023] [Revised: 05/01/2024] [Accepted: 05/02/2024] [Indexed: 05/14/2024] Open
Abstract
BACKGROUND Anatomic patellar components for total knee arthroplasty (TKA) have demonstrated favorable in vivo kinematics. A novel failure mechanism in TKA patients with an anatomic patellar component was observed prompting an investigation to identify patient- and implant-related factors associated with suboptimal performance. METHODS A retrospective evaluation was performed comparing 100 TKA patients with an anatomic patellar component to 100 gender-, age-, and body mass index-matched patients with a medialized dome component. All surgeries were performed with the same posterior-stabilized TKA system with minimum of 1-year follow-up. Several radiographic parameters were assessed. A separate computational evaluation was performed using finite-element analysis, comparing bone strain energy density through the patella bone remnant. RESULTS Patients with an anatomic patellar component had significantly higher rates of anterior knee pain (18 versus 2%, P < .001), chronic effusions (18 versus 2%, P < .001), and superior patellar pole fragmentation (36 versus 13%, P < .001) compared to those with a dome component. Radiographically, the anatomic group demonstrated more lateral patellar subluxation (2.3 versus 1.1 mm, P < .001) and lateral tilt (5.4 versus 4.0 mm, P = .013). Furthermore, there were more revisions in the anatomic group (7 versus 3, P = .331). On computational evaluation, all simulations demonstrated increased bone strain energy density at the superior patellar pole with the anatomic patella. Resection thickness <13 mm resulted in over 2-fold higher strain energy density, and negative resection angle of 7° resulted in 6-fold higher superior pole strain energy. CONCLUSIONS Patients with an anatomic patellar component showed higher rates of anterior knee pain, chronic effusion, and superior pole fragmentation compared to patients with a dome patella, with higher superior patellar pole strain energy confirmed on computational evaluation. Avoiding higher resection angles and excessive patellar resection may improve the performance and survivorship of the anatomic patella.
Collapse
Affiliation(s)
| | - Jessell M Owens
- Swift Institute, Sparks, Nevada; Colorado Joint Replacement, Denver, Colorado
| | | | - Chadd W Clary
- Center for Orthopaedic Biomechanics, University of Denver, Denver, Colorado
| | - Jacob M Elkins
- Department of Orthopaedics, University of Iowa, Iowa City, Iowa
| | - Douglas A Dennis
- Colorado Joint Replacement, Denver, Colorado; Department of Bioengineering, University of Tennessee, Knoxville, Tennessee; Denver University, Denver, Colorado; Department of Orthopaedics, University of Colorado School of Medicine, Denver, Colorado
| |
Collapse
|
29
|
Brendle SA, Krueger S, Grifka J, Müller PE, Grupp TM. A New Methodology for the Accurate Measurement of Tibiofemoral Kinematics in Human Cadaveric Knees: An Evaluation of the Anterior-Posterior Laxity Pre- and Post-Cruciate Ligament Resection. Life (Basel) 2024; 14:877. [PMID: 39063630 PMCID: PMC11278153 DOI: 10.3390/life14070877] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2024] [Revised: 07/08/2024] [Accepted: 07/12/2024] [Indexed: 07/28/2024] Open
Abstract
Anterior-posterior (AP) stability is an important measure of knee performance after total knee arthroplasty (TKA). To improve the stabilizing effect of implants designed to compensate for the loss of the cruciate ligaments, it is important to understand the tibiofemoral contact situation within the native ligamentous situation of the knee and how it changes after cruciate ligament resection. This in vitro study introduces a new approach to accurately measure the tibiofemoral kinematics in a six-degrees-of-freedom joint motion simulator by tracking landmark-based coordinate systems and their corresponding bone geometries. The tibiofemoral contact situation was investigated by projecting the medial and lateral flexion facet centers onto the tibial plateau under AP shear forces across various flexion angles in thirteen knees. Tests were conducted pre- and post-cruciate ligament resection. Post-cruciate ligament resection, the femoral condyles shifted closer to or even exceeded the posterior border of the tibial plateau, but only slightly closer to the anterior border. This study presents a new methodology for measuring the tibiofemoral kinematics that can be applied to multiple loading profiles. It provides a basis for further investigations, including passive or active muscle forces, to enhance the design of total knee protheses and improve surgical outcomes.
Collapse
Affiliation(s)
- Saskia A. Brendle
- Research & Development, Aesculap AG, 78532 Tuttlingen, Germany
- Department of Orthopaedic and Trauma Surgery, Musculoskeletal University Center Munich (MUM), Campus Grosshadern, LMU Munich, 81377 Munich, Germany
| | - Sven Krueger
- Research & Development, Aesculap AG, 78532 Tuttlingen, Germany
| | - Joachim Grifka
- Department of Orthopaedics, Asklepios Klinikum, 93077 Bad Abbach, Germany
| | - Peter E. Müller
- Department of Orthopaedic and Trauma Surgery, Musculoskeletal University Center Munich (MUM), Campus Grosshadern, LMU Munich, 81377 Munich, Germany
| | - Thomas M. Grupp
- Research & Development, Aesculap AG, 78532 Tuttlingen, Germany
- Department of Orthopaedic and Trauma Surgery, Musculoskeletal University Center Munich (MUM), Campus Grosshadern, LMU Munich, 81377 Munich, Germany
| |
Collapse
|
30
|
Di Maria F, Das S, Abermann E, Hoser C, Fink C. Pulsed lavage is associated with better quality of bone-cement-implant interface in knee arthroplasties (TKA/UKA) compared to syringe lavage in vitro; however, clinical data are missing: A systematic review. J Exp Orthop 2024; 11:e12027. [PMID: 38774578 PMCID: PMC11106550 DOI: 10.1002/jeo2.12027] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/04/2023] [Revised: 03/08/2024] [Accepted: 03/15/2024] [Indexed: 05/24/2024] Open
Abstract
Purpose The purpose of this systematic review is to analyse the available literature to ascertain the optimal method of bone preparation to improve the quality of bone-cement-implant interface with either pulsed lavage or syringe lavage in both total knee arthroplasty (TKA) and unicompartmental knee arthroplasty (UKA). Methods A comprehensive search was conducted across MEDLINE, Scopus and Embase databases until July 2023. Both inclusion and exclusion criteria were clearly stated and used to identify all the published studies. Subsequent screening throughout the title, abstract and full text was made, followed by complete critical appraisal and data extraction. This sequential process was performed by two reviewers independently and summarised following the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines). A quality assessment of the systematic review was performed according to the Quality Appraisal for Cadaveric Studies scale (QUACS), reaching a quality level ranging from 69% to 85%. Results A total of 10 articles, out of 47, nine biomechanical cadaveric studies and one human clinical study were analysed. A total of 196 UKA tibial components, 74 patellar components, 36 TKA tibial components and 24 UKA femoral components were retrieved, and a high level of heterogeneity resulted overall. The pulsed lavage group showed better cement penetration and higher pull-out force than the syringe lavage group; a higher interface temperature was also found in the pulsed lavage group. No differences were found regarding tension ligament forces between the groups. Conclusion Our systematic review suggests that pulsed lavage is superior to syringe lavage in terms of the quality of bone-cement-implant interface in knee arthroplasties (TKA/UKA). However, translation of these results from cadaveric studies to individual clinical settings may be hazardous; therefore, clinical in vivo prospective studies are highly needed. PROSPERO CRD PROSPERO CRD number CRD42023432399. Level of Evidence Level III.
Collapse
Affiliation(s)
- Fabrizio Di Maria
- Gelenkpunkt‐Sports‐and Joint SurgeryFIFA Medical Centre of ExcellenceInnsbruckAustria
- Research Unit for Orthopaedic Sports Medicine and Injury Prevention (OSMI), Medical Informatics and TechnologyPrivate University for Health SciencesHallAustria
| | - Saubhik Das
- Gelenkpunkt‐Sports‐and Joint SurgeryFIFA Medical Centre of ExcellenceInnsbruckAustria
- Research Unit for Orthopaedic Sports Medicine and Injury Prevention (OSMI), Medical Informatics and TechnologyPrivate University for Health SciencesHallAustria
| | - Elisabeth Abermann
- Gelenkpunkt‐Sports‐and Joint SurgeryFIFA Medical Centre of ExcellenceInnsbruckAustria
- Research Unit for Orthopaedic Sports Medicine and Injury Prevention (OSMI), Medical Informatics and TechnologyPrivate University for Health SciencesHallAustria
| | - Christian Hoser
- Gelenkpunkt‐Sports‐and Joint SurgeryFIFA Medical Centre of ExcellenceInnsbruckAustria
- Research Unit for Orthopaedic Sports Medicine and Injury Prevention (OSMI), Medical Informatics and TechnologyPrivate University for Health SciencesHallAustria
| | - Christian Fink
- Gelenkpunkt‐Sports‐and Joint SurgeryFIFA Medical Centre of ExcellenceInnsbruckAustria
- Research Unit for Orthopaedic Sports Medicine and Injury Prevention (OSMI), Medical Informatics and TechnologyPrivate University for Health SciencesHallAustria
| |
Collapse
|
31
|
Campbell B, Weinberg M, Bischoff J, Scuderi GR. An Evaluation of Anatomic Referencing for Femoral Component Sizing Using Computed Tomography-Based Computer Modeling. J Knee Surg 2024; 37:638-641. [PMID: 38191007 DOI: 10.1055/a-2240-3566] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/10/2024]
Abstract
One of the critical steps in total knee arthroplasty is femoral component positioning and sizing. Historically, there was wider variability between femoral component sizes, necessitating the concepts of anterior referencing (AR) and posterior referencing (PR). With the introduction of smaller increments between sizes, the concept of anatomic referencing has been introduced to replace AR and PR. The intent of this study was to validate the concept of anatomic referencing and show that with 2 mm increments in femoral sizes, the femoral component can be placed flush to the anterior cortex while maintaining posterior condylar offset (PCO). Digital surface models were created using 515 femurs from an established computed tomography database. Virtual bone resections, component sizing and placement were performed assuming neutral mechanical axis and a cartilage thickness of 2 mm. The appropriately sized femoral component, which had 2 mm incremental sizes, was placed flush with the anterior cortex with restoration of the PCO. The anterior-posterior distance from the posterior surface of the component to the medial and lateral surfaces of the posterior condylar cartilage were measured. The medial condyle was the limiting condyle in the majority of cases (73%). The average medial gap after appropriate femoral component matching was 0.6 mm (0.39-1.41 mm) across all sizes. The overall average condylar gap was 1.02 mm. The most common femoral component was a size 7 (57.2 mm) and the average femoral AP width was 55.9 mm. Anatomic referencing with an implant system that has 2-mm increments in femoral component sizing provides an alternative to AR and PR without compromise. Anatomic referencing allows for perfect alignment of the anterior flange of the femoral component to the anterior cortex of the femur while restoring the native PCO to within 1 mm. This avoids having to choose between AR or PR when in between femoral sizes.
Collapse
Affiliation(s)
- Brett Campbell
- Department of Orthopedic Surgery, Penn State Health, St. Joe's Medical Center, Reading, Pennsylvania
| | - Max Weinberg
- Department of Orthopedic Surgery, Zucker School of Medicine at Hofstra/Northwell, Garden City, New York
| | | | - Giles R Scuderi
- Department of Orthopedic Surgery, Zucker School of Medicine at Hofstra/Northwell, Garden City, New York
| |
Collapse
|
32
|
Mika AP, Mulvey HE, Engstrom SM, Polkowski GG, Martin JR, Wilson JM. Can ChatGPT Answer Patient Questions Regarding Total Knee Arthroplasty? J Knee Surg 2024; 37:664-673. [PMID: 38442904 DOI: 10.1055/s-0044-1782233] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 03/07/2024]
Abstract
The internet has introduced many resources frequently accessed by patients prior to orthopaedic visits. Recently, Chat Generative Pre-Trained Transformer, an artificial intelligence-based chat application, has become publicly and freely available. The interface uses deep learning technology to mimic human interaction and provide convincing answers to questions posed by users. With its rapidly expanding usership, it is reasonable to assume that patients will soon use this technology for preoperative education. Therefore, we sought to determine the accuracy of answers to frequently asked questions (FAQs) pertaining to total knee arthroplasty (TKA).Ten FAQs were posed to the chatbot during a single online interaction with no follow-up questions or repetition. All 10 FAQs were analyzed for accuracy using an evidence-based approach. Answers were then rated as "excellent response not requiring clarification," "satisfactory requiring minimal clarification," satisfactory requiring moderate clarification," or "unsatisfactory requiring substantial clarification."Of the 10 answers given by the chatbot, none received an "unsatisfactory" rating with the majority either requiring minimal (5) or moderate (4) clarification. While many answers required nuanced clarification, overall, answers tended to be unbiased and evidence-based, even when presented with controversial subjects.The chatbot does an excellent job of providing basic, evidence-based answers to patient FAQs prior to TKA. These data were presented in a manner that will be easily comprehendible by most patients and may serve as a useful clinical adjunct in the future.
Collapse
Affiliation(s)
- Aleksander P Mika
- Department of Orthopedic Surgery, Vanderbilt University Medical Center, Nashville, Tennessee
| | - Hillary E Mulvey
- Department of Orthopedic Surgery, Vanderbilt University Medical Center, Nashville, Tennessee
| | - Stephen M Engstrom
- Department of Orthopedic Surgery, Vanderbilt University Medical Center, Nashville, Tennessee
| | - Gregory G Polkowski
- Department of Orthopedic Surgery, Vanderbilt University Medical Center, Nashville, Tennessee
| | - J Ryan Martin
- Department of Orthopedic Surgery, Vanderbilt University Medical Center, Nashville, Tennessee
| | - Jacob M Wilson
- Department of Orthopedic Surgery, Vanderbilt University Medical Center, Nashville, Tennessee
| |
Collapse
|
33
|
Anderson PM, Heinz T, Weißenberger M, Winter P, Rudert M, Jakuscheit A. Zirconium as a Promising Synovial Biomarker for Loose Cemented Knee Prosthesis. J Arthroplasty 2024; 39:1714-1718. [PMID: 38244639 DOI: 10.1016/j.arth.2024.01.019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/19/2023] [Revised: 12/21/2023] [Accepted: 01/09/2024] [Indexed: 01/22/2024] Open
Abstract
BACKGROUND Aseptic loosening is the most common mode of failure after total knee arthroplasty. Despite this, the diagnosis often remains challenging and mainly relies on imaging modalities. Until today, no biomarker exists to aid in diagnosing loosening of the implants. As zirconium (Zr) is often found in bone cement, where it serves as radiopacifier, this study aimed to establish Zr as a synovial biomarker for loosened cemented knee prostheses. METHODS A total of 31 patients scheduled for revision of a cemented knee prostheses were included. In all patients, the initial used cement contained Zr. After arthrotomy, specimens of synovial fluid were taken and levels of Zr were measured by inductively coupled plasma mass spectrometry. Depending on the necessary amount of force for explantation, the implants were graded "loose" or "well-fixed". Preoperative radiographs were evaluated by 2 independent physicians. RESULTS The concentration of Zr in the synovial fluid differed significantly (P < .001) between the "loose" (mean 170.9 μg/L, range 0 to 1941 μg/L) and the "well-fixed" (mean 0.6 μg/L, range 0 to 6 μg/L) implants. The receiver operating characteristic analysis revealed 0.25 μg/l as an optimal cutoff value leading to a sensitivity of 0.84, a specificity of 0.92, a positive predictive value of 0.94, and a negative predictive value of 0.79. There was no significant difference in the diagnostic performance compared to radiographs (P = .66). CONCLUSIONS Zirconium proved to be a reliable novel synovial biomarker for diagnosing aseptic loosening of knee prothesis fixed with cement containing Zr. This biomarker should not be interpreted in isolation, but in combination with existing diagnostic tools.
Collapse
Affiliation(s)
- Philip M Anderson
- Department of Orthopedics, Orthopädische Klinik König-Ludwig-Haus, University of Wuerzburg, Würzburg, Germany
| | - Tizian Heinz
- Department of Orthopedics, Orthopädische Klinik König-Ludwig-Haus, University of Wuerzburg, Würzburg, Germany
| | - Manuel Weißenberger
- Department of Orthopedics, Orthopädische Klinik König-Ludwig-Haus, University of Wuerzburg, Würzburg, Germany
| | - Philipp Winter
- Department of Orthopaedic Surgery, University of Saarland, Homburg, Germany
| | - Maximilian Rudert
- Department of Orthopedics, Orthopädische Klinik König-Ludwig-Haus, University of Wuerzburg, Würzburg, Germany
| | - Axel Jakuscheit
- Department of Orthopedics, Orthopädische Klinik König-Ludwig-Haus, University of Wuerzburg, Würzburg, Germany
| |
Collapse
|
34
|
Springorum HR, Baier C, Maderbacher G, Paulus A, Grifka J, Goetz J. Periprosthetic Joint Infections of the Knee-Comparison of Different Treatment Algorithms. J Clin Med 2024; 13:3718. [PMID: 38999284 PMCID: PMC11242078 DOI: 10.3390/jcm13133718] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2024] [Revised: 06/16/2024] [Accepted: 06/21/2024] [Indexed: 07/14/2024] Open
Abstract
Background: Periprosthetic joint infection (PJI) following total knee arthroplasty is a serious complication lacking evidence-based diagnostic and treatment protocols, particularly in ruling out persisting infection before reimplantation. Methods: This retrospective analysis assessed the mid-term outcomes of 66 patients undergoing septic two-stage knee revision surgeries from 2007 to 2013, diagnosed as per the Musculoskeletal Infection Society criteria. After implant removal and antibiotic treatment, reimplantation decisions were based on either joint aspiration, blood counts, and clinical examination (group A) or an open biopsy (group B). Both groups underwent meticulous debridement and spacer exchange during the interim period. Results: Late re-infection occurred in 12.1% of all patients. In group A, 13.8% experienced late re-infection, with 14.3% in subgroup A1 and 13.3% in subgroup A2. In group B, 10% had a late re-infection. No significant difference in re-infection or complication rates was found between the groups. Conclusions: The study did not demonstrate the superiority of group B's approach of open biopsy over group A's joint aspiration, clinical examination, and blood counts in preventing re-infection or reducing complications.
Collapse
Affiliation(s)
- Hans-Robert Springorum
- Orthopädisches Fachzentrum Weilheim-Garmisch-Starnberg-Penzberg, University Hospital Regensburg, 93077 Bad Abbach, Germany
| | - Clemens Baier
- University Hospital Regensburg, 93077 Bad Abbach, Germany
| | | | | | - Joachim Grifka
- Orthopaedic University Hospital Regensburg, 93077 Bad Abbach, Germany
| | - Juergen Goetz
- Medartes Praxisverbund Regensburg Neutraubling, University Hospital Regensburg, 93077 Bad Abbach, Germany
| |
Collapse
|
35
|
Guan S, Dumas R, Pandy MG. Tibiofemoral Slip Velocity in Total Knee Arthroplasty is Design-Invariant but Activity-Dependent. Ann Biomed Eng 2024; 52:1779-1794. [PMID: 38530534 PMCID: PMC11560988 DOI: 10.1007/s10439-024-03490-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2023] [Accepted: 03/11/2024] [Indexed: 03/28/2024]
Abstract
Tibiofemoral slip velocity is a key contributor to total knee arthroplasty (TKA) component wear, yet few studies have evaluated this quantity in vivo. The aim of the present study was to measure and compare tibiofemoral slip velocities in 3 TKA designs for a range of daily activities. Mobile biplane X-ray imaging was used to measure 6-degree-of-freedom tibiofemoral kinematics and the locations of articular contact in 75 patients implanted with a posterior-stabilized, cruciate-retaining, or medial-stabilized design while each patient performed level walking, step up, step down, sit-to-stand, and stand-to-sit. Using these data, tibiofemoral slip velocity was calculated for the duration of each activity for each TKA design. The pattern of tibiofemoral slip velocity was similar for all 3 TKA designs within each activity but markedly different across the 5 activities tested, with the magnitude of peak slip velocity being significantly higher in level walking (range: 158-211 mm/s) than in all other activities (range: 43-75 mm/s). The pattern of tibiofemoral slip velocity in both the medial and lateral compartments closely resembled the pattern of tibiofemoral (knee) flexion angular velocity, with a strong linear relationship observed between slip velocity and flexion angular velocity (r = 0.81-0.97). Tibiofemoral slip velocity was invariant to TKA design but was significantly affected by activity type. Our measurements of slip velocity and articular contact locations for a wide range of daily activities may be used as inputs in joint simulator testing protocols and computational models developed to estimate TKA component wear.
Collapse
Affiliation(s)
- Shanyuanye Guan
- Department of Mechanical Engineering, University of Melbourne, Parkville, Victoria, 3010, Australia
| | - Raphael Dumas
- University of Lyon, University Gustave Eiffel, University Claude Bernard Lyon 1, LBMC UMR T_9406, F-69622, Lyon, France
| | - Marcus G Pandy
- Department of Mechanical Engineering, University of Melbourne, Parkville, Victoria, 3010, Australia.
| |
Collapse
|
36
|
Dubin J, Hameed D, Moore MC, Bains SS, Patel S, Nace J, Mont MA, Delanois RE. Methodological Assessment of the 100 Most-Cited Articles in Total Knee Arthroplasty in the Last Decade Compared to the All-Time List. J Arthroplasty 2024; 39:1434-1443.e5. [PMID: 38135168 DOI: 10.1016/j.arth.2023.12.030] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/09/2023] [Revised: 12/04/2023] [Accepted: 12/15/2023] [Indexed: 12/24/2023] Open
Abstract
BACKGROUND Recent advances in total knee arthroplasty (TKA) have been driven by a growing focus on evidence-based medicine. This transition is reflected in the critical appraisal of both, the quality of work and the potential impact on the orthopedic community. The purpose of our study was to (1) identify the top 100 most-cited articles in TKA in the last decade and from all-time, and (2) compare methodological rigor of the most-cited articles in TKA in the last decade to articles all-time by level of evidence. METHODS The top 100 cited articles were recorded for manuscripts from the last decade, January 1, 2012 to December 31, 2022, and manuscripts from all-time for TKA. We collected authors, year of publication, journal of the article, country of origin of authors, article type (basic science article, clinical research article), level of evidence, methodological index for non-randomized studies score, physiotherapy evidence database scale, and citation density (total citations/years published). RESULTS The largest number of studies for all-time TKA (53.0%) and decade TKA (42.0%) were Level III. The average methodological index for non-randomized studies score for comparative studies was 18.7 for all-time TKA and 20.7 for decade TKA (P < .001). The average physiotherapy evidence database score was 6.1 for all-time TKA and 8.1 for decade TKA (P > .05). The highest citation density for all-time TKA was 111 and for past decade was 63. The number of level II studies in TKA increased from 19.0% from all time to 38.0% from the last decade (P < .05). CONCLUSIONS Our findings of improved methodologies over time reflect positive steps toward evidence-based practice in TKA. A continued focus on producing methodologically sound studies may guide evidence-based clinical decision-making.
Collapse
Affiliation(s)
- Jeremy Dubin
- Rubin Institute for Advanced Orthopedics, LifeBridge Health, Sinai Hospital of Baltimore, Baltimore, Maryland
| | - Daniel Hameed
- Rubin Institute for Advanced Orthopedics, LifeBridge Health, Sinai Hospital of Baltimore, Baltimore, Maryland
| | - Mallory C Moore
- Rubin Institute for Advanced Orthopedics, LifeBridge Health, Sinai Hospital of Baltimore, Baltimore, Maryland
| | - Sandeep S Bains
- Rubin Institute for Advanced Orthopedics, LifeBridge Health, Sinai Hospital of Baltimore, Baltimore, Maryland
| | - Saarang Patel
- Rubin Institute for Advanced Orthopedics, LifeBridge Health, Sinai Hospital of Baltimore, Baltimore, Maryland
| | - James Nace
- Rubin Institute for Advanced Orthopedics, LifeBridge Health, Sinai Hospital of Baltimore, Baltimore, Maryland
| | - Michael A Mont
- Rubin Institute for Advanced Orthopedics, LifeBridge Health, Sinai Hospital of Baltimore, Baltimore, Maryland
| | - Ronald E Delanois
- Rubin Institute for Advanced Orthopedics, LifeBridge Health, Sinai Hospital of Baltimore, Baltimore, Maryland
| |
Collapse
|
37
|
van Duren BH, Lee K, Firth AM, Imuetinyan E, Ilo K, Berber R, Matar HE, Bloch BV. Postoperative Continuous Passive Motion Does Not Improve the Range of Movement Achieved After Manipulation Under Anesthetic for Stiffness in Total Knee Replacement. Arthroplast Today 2024; 27:101397. [PMID: 38882466 PMCID: PMC11180303 DOI: 10.1016/j.artd.2024.101397] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/19/2023] [Revised: 03/25/2024] [Accepted: 04/02/2024] [Indexed: 06/18/2024] Open
Abstract
Background Stiffness is a common complication following total knee arthroplasty. Manipulation under anesthesia (MUA) is an intervention that can potentially improve range of motion (ROM). Continuous passive motion (CPM) therapy has been utilized to enhance post-MUA ROM, but its effectiveness remains debated. This study assesses whether CPM therapy after MUA results in superior ROM outcomes compared to MUA alone. Methods A retrospective analysis included patients undergoing MUA for stiff primary total knee arthroplasty between 2017 and 2022. Demographics and ROM data were collected. Patients were in 2 groups: those who received inpatient CPM post-MUA and those who received day-case MUA alone. Complications and further interventions were noted. Results Of 126 patients, 39 underwent MUA only (day-case group), and 87 received CPM and MUA (inpatient group). Mean preoperative ROM was 69.4° (standard deviation [SD]:18.0°) and 73.9° (SD: 18.1°) for inpatient and day-case groups, respectively. Mean post-MUA ROM improved by 39.4° (SD: 17.7°) and 25.5° (SD: 11.1°) inpatient groups and day-case, respectively. The mean percentage of ROM gained at MUA maintained at final follow-up was 63.7% (40.8%) and 67.0% (47.5%) inpatient and day-case groups, respectively. Conclusions This study found no advantage in the routine use of CPM post-MUA for stiff total knee replacement patients, suggesting it may not provide sustained ROM improvements compared to MUA alone. Cost-effectiveness and patient selection merit further investigation.
Collapse
Affiliation(s)
- Bernard H van Duren
- Nottingham Elective Orthopaedic Services, Nottingham University Hospitals NHS Trust, Nottingham, UK
- Leeds Institute of Rheumatic and Musculoskeletal Medicine, University of Leeds, Leeds, UK
| | - Katie Lee
- Nottingham Elective Orthopaedic Services, Nottingham University Hospitals NHS Trust, Nottingham, UK
| | - Amy M Firth
- Nottingham Elective Orthopaedic Services, Nottingham University Hospitals NHS Trust, Nottingham, UK
| | - Efosa Imuetinyan
- Nottingham Elective Orthopaedic Services, Nottingham University Hospitals NHS Trust, Nottingham, UK
| | - Kevin Ilo
- Nottingham Elective Orthopaedic Services, Nottingham University Hospitals NHS Trust, Nottingham, UK
| | - Reshid Berber
- Nottingham Elective Orthopaedic Services, Nottingham University Hospitals NHS Trust, Nottingham, UK
| | - Hosam E Matar
- Nottingham Elective Orthopaedic Services, Nottingham University Hospitals NHS Trust, Nottingham, UK
| | - Benjamin V Bloch
- Nottingham Elective Orthopaedic Services, Nottingham University Hospitals NHS Trust, Nottingham, UK
| |
Collapse
|
38
|
Panwar KS, Huish EG, Law JL, Deans JT, Staples JR, Eisemon EO, Lum ZC. Revision Total Joint Arthroplasty Places a Disproportionate Burden on Surgeons: A Comparison Using the National Aeronautics and Space Administration Task Load Index (NASA TLX). J Arthroplasty 2024; 39:1550-1556. [PMID: 38218555 DOI: 10.1016/j.arth.2024.01.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/17/2023] [Revised: 12/19/2023] [Accepted: 01/02/2024] [Indexed: 01/15/2024] Open
Abstract
BACKGROUND Perceived surgeon workload of performing primary and revision total hip arthroplasty (THA) and total knee arthroplasty (TKA) is challenging to quantify. The National Aeronautics and Space Administration Task Load Index (NASA TLX) survey was developed to quantify experiences following aviation and has been applied to healthcare fields. Our purposes were to 1) quantify the workload endured by surgeons who are performing primary and revision TKA and THA and 2) compare these values to their Center for Medicare & Medicaid Services (CMS) reimbursement. METHODS A prospective cohort of 5 fellowship-trained adult reconstruction surgeons completed NASA TLX surveys following primary and revision TKA/THA cases. A total of 122 surveys consisting of 70 TKA (48 primaries and 22 revisions) and 55 THA surveys (38 primaries and 17 revisions) were completed. Patient demographics and surgical variables were recorded. Final NASA TLX workloads were compared to 2021 CMS work relative value units. RESULTS Compared to primary TKA, revision TKA had 176% increased intraoperative workload (P < .001), 233% increased mental burden (P < .001), and 150% increased physical burden (P < .001). Compared to primary THA, revision THA had 106% increased intraoperative workload (P < .001), 96% increased mental burden (P < .001), and 91% increased physical burden (P < .001). Operative time was higher in revision versus primary TKA (118 versus 84.5 minutes, P = .05) and THA (150 versus 115 minutes, P = .001). Based upon 2021 CMS data, revision TKA and THA would need to be compensated by an additional 36% and 12.3%, respectively, to parallel intraoperative efforts. CONCLUSIONS Revision hip and knee arthroplasty places a major mental and physical workload upon surgeons and is disproportionately compensated by CMS.
Collapse
Affiliation(s)
- Kunal S Panwar
- Department of Orthopedic Surgery, San Joaquin General Hospital, Stockton, California
| | - Eric G Huish
- Department of Orthopedic Surgery, San Joaquin General Hospital, Stockton, California
| | - Jesua L Law
- Department of Orthopedic Surgery, Doctors Medical Center, Modesto, California
| | - Justin T Deans
- Department of Orthopedic Surgery, Doctors Medical Center, Modesto, California
| | - Jonathon R Staples
- Department of Orthopedic Surgery, Memorial Medical Center, Modesto, California
| | - Eric O Eisemon
- Department of Orthopedic Surgery, Kaiser Permanente, Oakland, California
| | - Zachary C Lum
- Department of Orthopaedic Surgery, UC Davis Medical Center, University of California, Sacramento, California
| |
Collapse
|
39
|
Hiranaka T. Current concept: personalized alignment total knee arthroplasty as a contrast to classical mechanical alignment total knee arthroplasty. ARTHROPLASTY 2024; 6:23. [PMID: 38705976 PMCID: PMC11071279 DOI: 10.1186/s42836-024-00246-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2023] [Accepted: 02/26/2024] [Indexed: 05/07/2024] Open
Abstract
Mechanical alignment (MA) total knee arthroplasty (TKA), with neutral leg alignment, mechanical component alignment, and parallel gaps, has achieved good long-term survival. Patient satisfaction, however, is not always perfect. In contrast to the MA, which aims for an ideal goal for all patients, an alternative has been proposed: kinematic alignment (KA)-TKA. In KA, the articular surface is replicated using components aligning with the three kinematic axes. KA-TKA has been gaining popularity, and in addition to the true or calipered KA, various derivatives, such as restricted KA, soft-tissue respecting KA, and functional alignments, have been introduced. Moreover, the functional approach encompasses several sub-approaches. This somewhat complicated scenario has led to some confusion. Therefore, the terminology needs to be re-organized. The term "personalized alignment (PA)" has been used in contrast to the MA approach, including all approaches other than MA. The term "PA-TKA" should be used comprehensively instead of KA and it represents the recent trends in distinct and unique consideration of each individual case. In addition to a comparison between MA and KA, we suggest that evaluation should be conducted to decide which approach is the best for an individual patient within the "personalized alignment" concept.
Collapse
Affiliation(s)
- Takafumi Hiranaka
- Department of Orthopaedic Surgery and Joint Surgery Centre, Takatsuki General Hospital, Osaka, 569-1192, Japan.
| |
Collapse
|
40
|
Costales TG, Dalury DF. Four-Year Outcomes of Cementless Versus Cemented Fixation of a Newly Introduced Total Knee Arthroplasty Design. Orthopedics 2024; 47:161-166. [PMID: 38285554 DOI: 10.3928/01477447-20240122-02] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2024]
Abstract
BACKGROUND Aseptic loosening continues to be a major cause of failure of total knee arthroplasty (TKA). Although cemented fixation remains the gold standard, there is renewed interest in cementless fixation as a means of decreasing this risk via biologic fixation. The purpose of this study was to evaluate the clinical outcomes of cemented and cementless versions of a newly introduced TKA design at an average of 4 years postoperatively. MATERIALS AND METHODS This was a retrospective case-control study of 100 primary TKAs comparing cementless vs cemented TKAs using the same cruciate-retaining implant design (ATTUNE Knee System; DePuy Synthes). Fifty patients undergoing cementless TKA with a mean age of 60.8 years (range, 48-71 years) and body mass index (BMI) of 31.6 kg/m2 (range, 23.7-41.9 kg/m2) were matched to 50 patients undergoing primary cemented TKA with a mean age of 62.7 years (range, 51-73 years) and BMI of 30.1 kg/m2 (range, 24.6-43.9 kg/m2). The mean follow-up was 4.2 years (range, 4.0-4.4 years) in the cementless group and 7.6 years (range, 7.5-7.7 years) in the cemented group. Complications, clinical outcomes using the Knee Society Score (KSS), and radiographic analyses were evaluated at final follow-up. Student's t tests were used for statistical analyses. RESULTS There was no statistical difference in age, BMI, and preoperative KSS between the two groups (P=.12, P=.15, and P=.55, respectively). There were no complications or reoperations in either cohort. There were no statistical differences in range of motion and total KSS at final follow-up between the two groups. Final total KSS had a mean of 91.1 for the cementless group and 93.7 for the cemented group. There was no radiographic evidence of component subsidence or loosening in either cohort. CONCLUSION When compared with its cemented counterpart, the newly introduced cementless TKA design had similar excellent clinical improvements and radiologic results at an average of 4 years of follow-up. [Orthopedics. 2024;47(3):161-166.].
Collapse
|
41
|
Lin J, Burge A, Li Q, Geannette C, Miller TT. Ultrasound assessment of synovitis in total knee replacements: concordance with MR imaging and joint aspiration. Skeletal Radiol 2024; 53:863-869. [PMID: 37930380 DOI: 10.1007/s00256-023-04485-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/29/2023] [Revised: 10/14/2023] [Accepted: 10/15/2023] [Indexed: 11/07/2023]
Abstract
OBJECTIVE To determine if diagnostic ultrasound can reliably distinguish between synovial patterns of prosthetic joint infection and polymeric wear in total knee replacements. METHODS AND METHODS This retrospective study was approved by our hospital IRB. Using the radiology report database, MR examinations performed within a week of diagnostic ultrasound and/or ultrasound-guided aspiration were identified. This yielded (1) 24 cases with MR and ultrasound comparisons; (2) 44 cases with MR, ultrasound, and aspiration comparisons; and (3) 92 cases with ultrasound and aspiration comparisons. The MR studies were reviewed by a musculoskeletal radiologist. The ultrasound studies were each reviewed by 2 other musculoskeletal radiologists. Each study was graded for synovial pattern indicating infection, polymeric wear, or normal/nonspecific. Agreement between the MR grader and the ultrasound graders as well as ultrasound inter-rater agreement were assessed using k statistics. Sensitivity, specificity, positive predictive value, and negative predictive value of ultrasound were calculated. RESULTS Agreement between ultrasound and MR imaging was fair to moderate: k of 0.27 (95% CI: 0.04, 0.50) and 0.44 (95% CI: 0.23, 0.65) for ultrasound raters 1 and 2, respectively. Inter-rater agreement between ultrasound graders 1 and 2 was moderate, with k of 0.56 (95% CI: 0.42, 0.70). Ultrasound sensitivities for infection were 0.13 and 0.09, while specificities were 0.94 and 0.98. Ultrasound sensitivities for polymeric wear were 0.38 and 0.62 with specificities of 0.90 and 0.76. CONCLUSION Ultrasound does not perform well in distinguishing patterns of synovitis either compared to MRI or a reference standard of aspiration/clinical follow-up.
Collapse
Affiliation(s)
- Ji Lin
- Department of Radiology and Imaging, Hospital for Special Surgery, 535 East 70th Street, New York, NY, 10021, USA.
| | - Alissa Burge
- Department of Radiology and Imaging, Hospital for Special Surgery, 535 East 70th Street, New York, NY, 10021, USA
| | - Qian Li
- Department of Radiology and Imaging, Hospital for Special Surgery, 535 East 70th Street, New York, NY, 10021, USA
| | - Christian Geannette
- Department of Radiology and Imaging, Hospital for Special Surgery, 535 East 70th Street, New York, NY, 10021, USA
| | - Theodore T Miller
- Department of Radiology and Imaging, Hospital for Special Surgery, 535 East 70th Street, New York, NY, 10021, USA
| |
Collapse
|
42
|
Coppola C, Greco M, Munir A, Musarò D, Quarta S, Massaro M, Lionetto MG, Maffia M. Osteoarthritis: Insights into Diagnosis, Pathophysiology, Therapeutic Avenues, and the Potential of Natural Extracts. Curr Issues Mol Biol 2024; 46:4063-4105. [PMID: 38785519 PMCID: PMC11119992 DOI: 10.3390/cimb46050251] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2024] [Revised: 04/05/2024] [Accepted: 04/18/2024] [Indexed: 05/25/2024] Open
Abstract
Osteoarthritis (OA) stands as a prevalent and progressively debilitating clinical condition globally, impacting joint structures and leading to their gradual deterioration through inflammatory mechanisms. While both non-modifiable and modifiable factors contribute to its onset, numerous aspects of OA pathophysiology remain elusive despite considerable research strides. Presently, diagnosis heavily relies on clinician expertise and meticulous differential diagnosis to exclude other joint-affecting conditions. Therapeutic approaches for OA predominantly focus on patient education for self-management alongside tailored exercise regimens, often complemented by various pharmacological interventions primarily targeting pain alleviation. However, pharmacological treatments typically exhibit short-term efficacy and local and/or systemic side effects, with prosthetic surgery being the ultimate resolution in severe cases. Thus, exploring the potential integration or substitution of conventional drug therapies with natural compounds and extracts emerges as a promising frontier in enhancing OA management. These alternatives offer improved safety profiles and possess the potential to target specific dysregulated pathways implicated in OA pathogenesis, thereby presenting a holistic approach to address the condition's complexities.
Collapse
Affiliation(s)
- Chiara Coppola
- Department of Mathematics and Physics “E. De Giorgi”, University of Salento, Via Lecce-Arnesano, 73100 Lecce, Italy; (C.C.); (A.M.)
| | - Marco Greco
- Department of Biological and Environmental Science and Technology, University of Salento, Via Lecce-Monteroni, 73100 Lecce, Italy; (M.G.); (D.M.); (S.Q.); (M.G.L.)
| | - Anas Munir
- Department of Mathematics and Physics “E. De Giorgi”, University of Salento, Via Lecce-Arnesano, 73100 Lecce, Italy; (C.C.); (A.M.)
| | - Debora Musarò
- Department of Biological and Environmental Science and Technology, University of Salento, Via Lecce-Monteroni, 73100 Lecce, Italy; (M.G.); (D.M.); (S.Q.); (M.G.L.)
| | - Stefano Quarta
- Department of Biological and Environmental Science and Technology, University of Salento, Via Lecce-Monteroni, 73100 Lecce, Italy; (M.G.); (D.M.); (S.Q.); (M.G.L.)
| | - Marika Massaro
- Institute of Clinical Physiology (IFC), National Research Council (CNR), 73100 Lecce, Italy;
| | - Maria Giulia Lionetto
- Department of Biological and Environmental Science and Technology, University of Salento, Via Lecce-Monteroni, 73100 Lecce, Italy; (M.G.); (D.M.); (S.Q.); (M.G.L.)
| | - Michele Maffia
- Department of Experimental Medicine, University of Salento, Via Lecce-Monteroni, 73100 Lecce, Italy
| |
Collapse
|
43
|
Schreiner MM, Straub J, Apprich S, Staats K, Windhager R, Aletaha D, Böhler C. The influence of biological DMARDs on aseptic arthroplasty loosening: a retrospective cohort study. Rheumatology (Oxford) 2024; 63:970-976. [PMID: 37402609 PMCID: PMC10986799 DOI: 10.1093/rheumatology/kead304] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2023] [Revised: 05/21/2023] [Accepted: 06/08/2023] [Indexed: 07/06/2023] Open
Abstract
OBJECTIVE To investigate whether biological DMARDs affect the risk of aseptic loosening after total hip/knee arthroplasty (THA/TKA) in patients with RA. METHODS We retrospectively identified all patients suffering from RA who underwent THA/TKA at our academic centre between 2002 and 2015 and linked them with an existing prospective observational RA database at our institution. The risk of aseptic loosening was estimated using radiological signs of component loosening (RCL). A time-dependent Cox regression analysis was used to compare the risk of implant loosening between patients treated with traditional DMARDS and biological DMARDs, or alternately both over time. RESULTS A total of 155 consecutive total joint arthroplasties (TJAs) (103 TKA vs 52 THA) was retrospectively included in the study. Mean age at implantation was 59 ± 13 years. Mean follow-up time was 69 ± 43 months. Overall, 48 (31%) TJAs showed signs of RCL, with 28 (27.2%) RCLs occurring after TKA compared with 20 after THA (38.5%). A significant difference regarding the incidence of RCL between the traditional DMARDs group (39 cases of RCL, 35%) and the biological DMARDs group (nine cases of RCL, 21%) (P = 0.026) was observed using the log-rank test. This was also true when using a time-dependent Cox regression with therapy as well as arthroplasty location (hip vs knee) as variables (P = 0.0447). CONCLUSION Biological DMARDs may reduce the incidence of aseptic loosening after TJA in patients with RA compared with traditional DMARDs. This effect seems to be more pronounced after TKA than THA.
Collapse
Affiliation(s)
- Markus M Schreiner
- Department of Orthopedics and Trauma Surgery, Medical University of Vienna, Vienna, Austria
| | - Jennifer Straub
- Department of Orthopedics and Trauma Surgery, Medical University of Vienna, Vienna, Austria
| | - Sebastian Apprich
- Department of Orthopedics and Trauma Surgery, Medical University of Vienna, Vienna, Austria
| | - Kevin Staats
- Department of Orthopedics and Trauma Surgery, Medical University of Vienna, Vienna, Austria
| | - Reinhard Windhager
- Department of Orthopedics and Trauma Surgery, Medical University of Vienna, Vienna, Austria
| | - Daniel Aletaha
- Department of Rheumatology, Medical University of Vienna, Vienna, Austria
| | - Christoph Böhler
- Department of Orthopedics and Trauma Surgery, Medical University of Vienna, Vienna, Austria
| |
Collapse
|
44
|
Laperche JM, Chang K, Albright JA, Ibrahim Z, Zhang H, Daniels AH, Barrett TJ. Shoulder Adhesive Capsulitis Prior to Total Knee Arthroplasty is Associated With Increased Rates of Postoperative Stiffness Requiring Manipulation Under Anesthesia and Arthroscopic Lysis of Adhesions. J Arthroplasty 2024; 39:960-965. [PMID: 37924990 DOI: 10.1016/j.arth.2023.10.051] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/03/2023] [Revised: 10/23/2023] [Accepted: 10/26/2023] [Indexed: 11/06/2023] Open
Abstract
BACKGROUND Arthrofibrosis following total knee arthroplasty (TKA) and adhesive capsulitis (AC) of the shoulder develop via a similar pathologic process. The purpose of this study was to examine the relationship between these two conditions. METHODS This was a retrospective cohort study using a large nationwide claims database. Patients who had a history of shoulder AC prior to TKA were compared to TKA patients who did not have AC history comparing rates of postoperative stiffness, manipulation under anesthesia (MUA), arthroscopic lysis of adhesions (LOAs), and revision arthroplasty at postoperative timepoints (3 months, 6 months, 1 year, and 2 years). RESULTS Within 3 months, 6 months, 1 year, and 2 years of their TKAs, patients who had a history of AC prior to TKA were significantly more likely to experience stiffness (OR [odds ratio] = 1.29, 1.28, 1.32, and 1.36, respectively) and LOAs (OR = 6.78, 3.65, 2.99, and 2.81, respectively). They also showed increased risk of MUA within 6 months, 1 year, and 2 years (OR = 1.15, 1.15, and 1.16, respectively) of their TKAs. Patients having a preoperative diagnosis of AC did not have an increased risk of undergoing revision surgery 1 year or 2 years after their TKAs (P > .05). CONCLUSIONS Patients diagnosed with AC prior to TKA experience higher rates of postoperative stiffness, resulting in additional interventions such as MUA and LOAs. These findings identify a particularly high-risk patient population that may benefit from additional interventions prior to and following TKA. LEVEL OF EVIDENCE This is a level III prognostic study.
Collapse
Affiliation(s)
- Jacob M Laperche
- Frank H. Netter School of Medicine, Quinnipiac University, North Haven, Connecticut; Department of Orthopedic Surgery, University Orthopedics, Providence, Rhode Island
| | - Kenny Chang
- The Warren Alpert Medical School of Brown University, Providence, Rhode Island
| | - James A Albright
- The Warren Alpert Medical School of Brown University, Providence, Rhode Island
| | - Zainab Ibrahim
- Department of Orthopaedic Surgery, Brown University, Providence, Rhode Island
| | - Helen Zhang
- The Warren Alpert Medical School of Brown University, Providence, Rhode Island
| | - Alan H Daniels
- Department of Orthopedic Surgery, University Orthopedics, Providence, Rhode Island; Department of Orthopaedic Surgery, Brown University, Providence, Rhode Island
| | - Thomas J Barrett
- Department of Orthopedic Surgery, University Orthopedics, Providence, Rhode Island; Department of Orthopaedic Surgery, Brown University, Providence, Rhode Island
| |
Collapse
|
45
|
Saeed AZ, Khaleeq T, Ahmed U, Ajula R, Boutefnouchet T, D'Alessandro P, Malik SS. No clinical advantage with customized individually made implants over conventional off-the-shelf implants in total knee arthroplasty: a systematic review and meta-analysis. Arch Orthop Trauma Surg 2024; 144:1311-1330. [PMID: 37979098 DOI: 10.1007/s00402-023-05090-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/15/2023] [Accepted: 09/25/2023] [Indexed: 11/19/2023]
Abstract
INTRODUCTION Total knee arthroplasty (TKA) can be performed with either conventional off-the-shelf (OTS) or customized individually-made (CIM) implants. The evidence for CIM implants is limited and variable, and the aim of this review was to compare clinical and radiological outcomes between CIM and OTS implants. METHODS A systematic review and meta-analysis were conducted in accordance with PRISMA guidelines. Studies reporting on clinical, radiological, or alignment outcomes for CIM and OTS implants were selected. The studies were appraised using the Methodical index for non-randomized studies tool. RESULTS Twenty-three studies fulfilled the inclusion criteria. The studies comprised 2856 CIM and 1877 OTS TKAs. Revision rate was higher with CIM (5.9%) compared to OTS (3.7%) implants [OR 1.23(95% CI 0.69-2.18)]. Manipulation under anesthesia (MUA) was higher in CIM (2.2%) compared to OTS (1.1%) group [OR 2.95(95% CI 0.95-9.13)] and complications rate was higher in CIM (5%) vs. OTS (4.5%) [OR 1.45(95% CI 0.53-3.96)] but neither reached statistical significance. Length of stay was significantly shorter in CIM group 2.9 days vs. 3.5 days [MD - 0.51(95% CI - 0.82 to - 0.20)]. Knee Society Score showed no difference between CIM and OTS groups for Knee 90.5 vs. 90.6 [MD - 0.27(95% CI - 4.27 to 3.73)] and Function 86.1 vs. 83.1 [MD 1.51(95% CI - 3.69 to 6.70)]. CONCLUSION CIM implants in TKA have theoretical benefits over OTS prostheses. However, in this present review, CIM implants were associated with higher revisions, MUA, and overall complication rates. There was no difference in outcome score and CIM implants did not improve overall target alignment; however, more CIM TKAs were found to be in the HKA target zone compared to OTS TKAs. The findings of this review do not support the general utilization of CIM over OTS implants in TKA.
Collapse
Affiliation(s)
- Abu Z Saeed
- The Robert Jones and Agnes Hunt Orthopaedic Hospital, Gobowen, Oswestry, SY10 7AG, UK.
| | - Tahir Khaleeq
- The Robert Jones and Agnes Hunt Orthopaedic Hospital, Gobowen, Oswestry, SY10 7AG, UK
| | - Usman Ahmed
- Worcestershire Acute Hospitals NHS Trust, Worcester, UK
| | - Randeep Ajula
- University Hospitals of Leicester NHS Trust, Leicester, UK
| | | | - Peter D'Alessandro
- Orthopaedic Research Foundation of Western Australia, Medical School, Discipline of Surgery, University of Western Australia, Perth, Australia
| | | |
Collapse
|
46
|
Pondugula P, Krumme JW, Seedat R, Patel NK, Golladay GJ. Evaluation of painful total knee arthroplasty: an approach based on common etiologies for total knee arthroplasty revision. Musculoskelet Surg 2024; 108:11-20. [PMID: 37987959 DOI: 10.1007/s12306-023-00800-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2022] [Accepted: 10/24/2023] [Indexed: 11/22/2023]
Abstract
A differential diagnosis with emphasis on the common indications for revision should be utilized in the workup of painful total knee arthroplasty (TKA). The physician should identify the exact etiology of the patient's pain to maximize outcomes from treatment. Evaluation for infection should be completed using the Musculoskeletal Infection Society (MSIS) criteria. When common causes of revision TKA do not appear to be the cause of the pain, less likely causes should be not be ignored. Further advancements such as pressure sensing devices may be able to improve patient satisfaction and decrease the incidence of pain following TKA.
Collapse
Affiliation(s)
- P Pondugula
- Department of Orthopedic Surgery, Virginia Commonwealth University Medical Center, PO Box 980153, Richmond, VA, 23298, USA
| | - J W Krumme
- Department of Orthopedic Surgery, Virginia Commonwealth University Medical Center, PO Box 980153, Richmond, VA, 23298, USA
| | - R Seedat
- Department of Orthopedic Surgery, Virginia Commonwealth University Medical Center, PO Box 980153, Richmond, VA, 23298, USA
| | - N K Patel
- Department of Orthopedic Surgery, Virginia Commonwealth University Medical Center, PO Box 980153, Richmond, VA, 23298, USA
| | - G J Golladay
- Department of Orthopedic Surgery, Virginia Commonwealth University Medical Center, PO Box 980153, Richmond, VA, 23298, USA.
| |
Collapse
|
47
|
Kirchner GJ, Stambough JB, Jimenez E, Nikkel LE. Robotic-assisted TKA is Not Associated With Decreased Odds of Early Revision: An Analysis of the American Joint Replacement Registry. Clin Orthop Relat Res 2024; 482:303-310. [PMID: 37962943 PMCID: PMC10776156 DOI: 10.1097/corr.0000000000002783] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/12/2023] [Accepted: 06/27/2023] [Indexed: 11/15/2023]
Abstract
BACKGROUND Robotic-assisted TKA continues to see wider clinical use, despite limited knowledge of its impact on patient satisfaction and implant survival. Most studies to date have presented small cohorts and came from single-surgeon or single-center experiences. Therefore, a population-level comparison of revision rates between robotic-assisted and conventional TKA in the registry setting may help arthroplasty surgeons better define whether robotic assistance provides a meaningful advantage compared with the conventional technique. QUESTIONS/PURPOSES (1) After controlling for confounding variables, such as surgeon, location of surgery, and patient comorbidity profile, were robotic-assisted TKAs less likely than conventional TKAs to result in revision for any reason at 2 years? (2) After again controlling for confounding variables, were robotic-assisted TKAs less likely to result in any specific reasons for revision than the conventional technique at 2 years? METHODS The American Joint Replacement Registry was used to identify patients 65 years or older who underwent TKA between January 2017 and March 2020 with a minimum of 2 years of follow-up. Patients were limited to age 65 yeas or older to link TKAs to Medicare claims data. Two retrospective cohorts were created: robotic-assisted TKA and conventional TKA. Patient demographic variables included in the analysis were age, gender, BMI, and race. Additional characteristics included the Charlson comorbidity index, anesthesia type, year of the index procedure, and length of stay. A total of 10% (14,216 of 142,550) of TKAs performed during this study period used robotics. Patients with robotic-assisted TKA and those with conventional TKA were similar regarding age (73 ± 6 years versus 73 ± 6 years; p = 0.31) and gender (62% [8736 of 14,126] versus 62% [79,399 of 128,334] women; p = 0.34). A multivariable, mixed-effects logistic regression model was created to analyze the odds of all-cause revision as a factor of robot use, and a logistic regression model was created to investigate specific revision diagnoses. RESULTS After controlling for potentially confounding variables, such as surgeon, location of surgery, and Charlson comorbidity index, we found no difference between the robotic-assisted and conventional TKAs in terms of the odds of revision at 2 years (OR of robotic-assisted versus conventional TKA 1.0 [95% CI 0.8 to 1.3]; p = 0.92). The reasons for revision of robotic-assisted TKA did not differ from those of conventional TKA, except for an increased odds of instability (OR 1.6 [95% CI 1.0 to 2.4]; p = 0.04) and pain (OR 2.1 [95% CI 1.4 to 3.0]; p < 0.001) in the robotic-assisted cohort. CONCLUSION In light of these findings, surgeons should not assume that robotic assistance in TKA will lead to improved early implant survival. Our findings do not support an improvement over conventional TKA with robotic assistance with regards to common causes of early revisions such malalignment, malposition, stiffness, pain, and instability, and in some cases, suggest there is a benefit to conventional TKA. Differences in the mid-term and long-term revision risk with conventional versus robotic-assisted TKA remain unknown. Appropriate informed consent around the use of robotic assistance should not imply decreased early revision risk. LEVEL OF EVIDENCE Level III, therapeutic study.
Collapse
Affiliation(s)
- Gregory J. Kirchner
- Department of Orthopaedics and Rehabilitation, Penn State Milton S. Hershey Medical Center, Hershey, PA, USA
| | - Jeffrey B. Stambough
- Department of Orthopaedic Surgery, University of Arkansas for Medical Sciences, Little Rock, AR, USA
| | - Emily Jimenez
- American Academy of Orthopaedic Surgeons, Rosemont, IL, USA
| | - Lucas E. Nikkel
- Department of Orthopaedic Surgery, Johns Hopkins Medicine, Columbia, MD, USA
| |
Collapse
|
48
|
Al-Nasser S, Noroozi S, Harvey A, Aslani N, Haratian R. Exploring the Performance of an Artificial Intelligence-Based Load Sensor for Total Knee Replacements. SENSORS (BASEL, SWITZERLAND) 2024; 24:585. [PMID: 38257676 PMCID: PMC10821047 DOI: 10.3390/s24020585] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/22/2023] [Revised: 01/11/2024] [Accepted: 01/15/2024] [Indexed: 01/24/2024]
Abstract
Using tibial sensors in total knee replacements (TKRs) can enhance patient outcomes and reduce early revision surgeries, benefitting hospitals, the National Health Services (NHS), stakeholders, biomedical companies, surgeons, and patients. Having a sensor that is accurate, precise (over the whole surface), and includes a wide range of loads is important to the success of joint force tracking. This research aims to investigate the accuracy of a novel intraoperative load sensor for use in TKRs. This research used a self-developed load sensor and artificial intelligence (AI). The sensor is compatible with Zimmer's Persona Knee System and adaptable to other knee systems. Accuracy and precision were assessed, comparing medial/lateral compartments inside/outside the sensing area and below/within the training load range. Five points were tested on both sides (medial and lateral), inside and outside of the sensing region, and with a range of loads. The average accuracy of the sensor was 83.41% and 84.63% for the load and location predictions, respectively. The highest accuracy, 99.20%, was recorded from inside the sensing area within the training load values, suggesting that expanding the training load range could enhance overall accuracy. The main outcomes were that (1) the load and location predictions were similar in accuracy and precision (p > 0.05) in both compartments, (2) the accuracy and precision of both predictions inside versus outside of the triangular sensing area were comparable (p > 0.05), and (3) there was a significant difference in the accuracy of load and location predictions (p < 0.05) when the load applied was below the training loading range. The intraoperative load sensor demonstrated good accuracy and precision over the whole surface and over a wide range of load values. Minor improvements to the software could greatly improve the results of the sensor. Having a reliable and robust sensor could greatly improve advancements in all joint surgeries.
Collapse
Affiliation(s)
- Samira Al-Nasser
- Bournemouth University, Fern Barrow, Poole BH12 3BB, UK; (S.A.-N.); (R.H.)
| | - Siamak Noroozi
- Bournemouth University, Fern Barrow, Poole BH12 3BB, UK; (S.A.-N.); (R.H.)
| | - Adrian Harvey
- Royal Bournemouth Hospital, Castle Ln E, Bournemouth BH7 7DW, UK;
| | - Navid Aslani
- Innovid Tech Ltd., 107b Athenlay Road, London SE15 3EJ, UK;
| | - Roya Haratian
- Bournemouth University, Fern Barrow, Poole BH12 3BB, UK; (S.A.-N.); (R.H.)
| |
Collapse
|
49
|
Wautier D, Thienpont E. Tibial implant design in primary TKA: retrospective comparison of two designs for the occurrence of radiolucent lines and aseptic loosening. Arch Orthop Trauma Surg 2024; 144:323-332. [PMID: 37733127 DOI: 10.1007/s00402-023-05030-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/11/2023] [Accepted: 08/09/2023] [Indexed: 09/22/2023]
Abstract
INTRODUCTION The purpose of this retrospective study was to study the effect of tibial implant design on the occurrence of radiolucent lines (RLLs) and aseptic loosening (AL) by comparing two different total knee arthroplasty (TKA) designs. MATERIALS AND METHODS Two types of total knee arthroplasty, different for tibial shape, size and keel design were compared, 255 for the first and 774 for the second. The occurrence of RLLs and radiological signs of micro- and macro-mobility and aseptic loosening was analyzed. Demographic data were compared, as well as the type and rate of RLLs, occurrence of aseptic loosening and the presence of potential risk factors. RESULTS The first implant design is morphometric and has a squarer keel than the second implant TKA. The overall rate of RLLs was similar (21% vs 23%), despite of a significantly lower rates of radiological signs of macro-mobility of the tibial component with the first implant (2% vs 17%). Survivorship of both designs was overall comparable (99.6% vs 98.8 %) the first implant group had more potential risk factors for poor bone quality than the second group (p < 0.05). CONCLUSION A morphometric design is more anatomic and offers better bone coverage of the epiphyseal tibial surface. RLLs, as a sign of implant micro-mobility, were equally present in both designs. Radiological signs of macro-mobility at the metaphysis were less frequently observed in squared keel design. The morphometric implant did not show improved survivorship compared with a symmetric implant. LEVEL OF EVIDENCE III.
Collapse
Affiliation(s)
- D Wautier
- Department of Orthopedic Surgery, CHU UCL Namur, Godinne, Avenue Docteur Gaston Therasse 1, 5530, Yvoir, Belgium.
| | - E Thienpont
- Department of Orthopedic Surgery, Cliniques Universitaires Saint-Luc, Avenue Hippocrate 10, 1200, Brussels, Belgium
| |
Collapse
|
50
|
Pijls BG. Technology assistance in primary total knee replacement: hype or hope? Expert Rev Med Devices 2024; 21:11-14. [PMID: 37992036 DOI: 10.1080/17434440.2023.2287576] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2023] [Accepted: 11/21/2023] [Indexed: 11/24/2023]
Abstract
INTRODUCTION Total knee replacement (TKR) reduces pain, it increases quality of life and it generally lasts a long time with revision rates of less than 5% at 10 years. Some authors have suggested that outcomes may be further improved by technology assistance. AREAS COVERED Technology assistance in primary TKR includes technologies such as navigated TKR, patient specific instrumentation TKR and robotic TKR. EXPERT OPINION In general, technology assistance results in higher accuracy of component positioning and alignment, but this is likely not clinically relevant as no clinically important difference in clinical outcomes, quality of life and complications such as revisions has been demonstrated in meta-analyses of randomized controlled trials. As technology assistance in primary TKR is increasingly used to capture patient and surgeon data, surgeons have an increasingly important role in protecting their patients' data and their own data. Real world evidence of implant registries has shown that TKR without technologically assistance can achieve perfectly acceptable outcomes. Although there is a genuine hope that technology-assisted TKR may further improve these outcomes, this hope is based on promises rather than solid evidence. At the same time, technology assisted TKR is heavily promoted including direct patient marketing, which are aspects of a hype.
Collapse
Affiliation(s)
- Bart G Pijls
- Department of Orthopaedics, Leiden University Medical Center, Leiden, The Netherlands
| |
Collapse
|