Asrani SG, McGlumphy EJ, Al-Aswad LA, Chaya CJ, Lin S, Musch DC, Pitha I, Robin AL, Wirostko B, Johnson TV. The relationship between intraocular pressure and glaucoma: An evolving concept. Prog Retin Eye Res 2024; 103:101303. [PMID: 39303763 DOI: 10.1016/j.preteyeres.2024.101303] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2024] [Revised: 09/17/2024] [Accepted: 09/18/2024] [Indexed: 09/22/2024]
Abstract
Intraocular pressure (IOP) is the most important modifiable risk factor for glaucoma and fluctuates considerably within patients over short and long time periods. Our field's understanding of IOP has evolved considerably in recent years, driven by tonometric technologies with increasing accuracy, reproducibility, and temporal resolution that have refined our knowledge regarding the relationship between IOP and glaucoma risk and pathogenesis. The goal of this article is to review the published literature pertinent to the following points: 1) the factors that determine IOP in physiologic and pathologic states; 2) technologies for measuring IOP; 3) scientific and clinical rationale for measuring diverse IOP metrics in patients with glaucoma; 4) the impact and shortcomings of current standard-of-care IOP monitoring approaches; 5) recommendations for approaches to IOP monitoring that could improve patient outcomes; and 6) research questions that must be answered to improve our understanding of how IOP contributes to disease progression. Retrospective and prospective data, including that from landmark clinical trials, document greater IOP fluctuations in glaucomatous than healthy eyes, tendencies for maximal daily IOP to occur outside of office hours, and, in addition to mean and maximal IOP, an association between IOP fluctuation and glaucoma progression that is independent of mean in-office IOP. Ambulatory IOP monitoring, measuring IOP outside of office hours and at different times of day and night, provides clinicians with discrete data that could improve patient outcomes. Eye care clinicians treating glaucoma based on isolated in-office IOP measurements may make treatment decisions without fully capturing the entire IOP profile of an individual. Data linking home blood pressure monitors and home glucose sensors to dramatically improved outcomes for patients with systemic hypertension and diabetes and will be reviewed as they pertain to the question of whether ambulatory tonometry is positioned to do the same for glaucoma management. Prospective randomized controlled studies are warranted to determine whether remote tonometry-based glaucoma management might reduce vision loss and improve patient outcomes.
Collapse
Affiliation(s)
- Sanjay G Asrani
- Department of Ophthalmology, Duke University Medical Center, Durham, NC, USA
| | | | - Lama A Al-Aswad
- Scheie Eye Institute, University of Pennsylvania, Philadelphia, PA, USA
| | - Craig J Chaya
- John A. Moran Eye Center, University of Utah, Salt Lake City, UT, USA
| | - Shan Lin
- Glaucoma Center of San Francisco, San Francisco, CA, USA
| | - David C Musch
- Department of Ophthalmology & Visual Sciences and Department of Epidemiology, Kellogg Eye Center, University of Michigan, Ann Arbor, MI, USA
| | - Ian Pitha
- Wilmer Eye Institute, Johns Hopkins University School of Medicine, Baltimore, MD, USA
| | - Alan L Robin
- Department of Ophthalmology & Visual Sciences and Department of Epidemiology, Kellogg Eye Center, University of Michigan, Ann Arbor, MI, USA; Wilmer Eye Institute, Johns Hopkins University School of Medicine, Baltimore, MD, USA
| | - Barbara Wirostko
- John A. Moran Eye Center, University of Utah, Salt Lake City, UT, USA.
| | - Thomas V Johnson
- Wilmer Eye Institute, Johns Hopkins University School of Medicine, Baltimore, MD, USA.
| |
Collapse
|
2
|
Kuo DS, Rahimy E. Agreement of Serial iCare HOME2 and Goldmann Applanation Tonometry. Ophthalmol Glaucoma 2024; 7:440-444. [PMID: 38679327 DOI: 10.1016/j.ogla.2024.04.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2024] [Revised: 04/15/2024] [Accepted: 04/22/2024] [Indexed: 05/01/2024]
Abstract
PURPOSE To assess agreement of iCare HOME2 and Goldmann applanation tonometry over a wide range of intraocular pressure (IOP). DESIGN A prospective, observational cohort study. SUBJECTS Twenty-six adult patients undergoing intravitreal injection, which temporarily raises IOP, were recruited from the Palo Alto Medical Foundation Retina Clinic between October 2022 and February 2023. METHODS Subjects had serial iCare HOME2 (IOPI) and Goldmann applanation (IOPG) IOP measurements before and at 0 and 5 to 10 minutes after injection. Baseline IOPs and pachymetry were taken in both eyes. MAIN OUTCOME MEASURES Correlation between IOPI and IOPG was tested by within-subjects intraclass correlation coefficient (ICC) for repeated measures. Agreement between IOPI and IOPG was evaluated by a Bland-Altman plot with correction for multiple measurements. The difference between IOPI and IOPG was evaluated between eyes at baseline (Pearson's r) and within the injected eye over different timepoints (ICC for absolute agreement). Linear regression was used to evaluate the effects of age, sex, glaucoma, and corneal thickness. RESULTS The mean IOPI and IOPG were 25.3 (range: 9-55) and 23.5 (range: 8-56) mmHg, respectively. The correlation between IOPI and IOPG was 0.99 (P < 0.001). The mean difference (IOPG - IOPI) was 2.2 mmHg (95% limits of agreement: -3.4 to 7.8 mmHg). The bias in measurements was correlated between eyes (r, 0.68; P < 0.001) and in the injected eye across all timepoints (ICC, 0.86; 95% CI, 0.75-0.93), but did not show a relationship with age, sex, glaucoma, or corneal thickness. CONCLUSIONS IOPI and IOPG showed excellent correlation; however, there was a stable bias toward IOPG being higher than IOPI over a large range of IOP. FINANCIAL DISCLOSURE(S) Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.
Collapse
Affiliation(s)
- Debbie S Kuo
- Department of Ophthalmology, Palo Alto Medical Foundation, Palo Alto, California.
| | - Ehsan Rahimy
- Department of Ophthalmology, Palo Alto Medical Foundation, Palo Alto, California; Byers Eye Institute, Horngren Family Vitreoretinal Center, Department of Ophthalmology, Stanford University School of Medicine, Palo Alto, California
| |
Collapse
|
3
|
Stewart C, Wu H, Alagappan U, Azuara-Blanco A, King AJ, Tatham AJ, Hernández R, Lowe B, Shotton D, Appiah N, Coffey T, Vadiveloo T, MacLennan G, Gillies K. Feasibility of in-home monitoring for people with glaucoma: the I-TRAC mixed-methods study. Health Technol Assess 2024; 28:1-163. [PMID: 39248430 PMCID: PMC11404360 DOI: 10.3310/gtwd6802] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/10/2024] Open
Abstract
Background Glaucoma is a chronic disease of the optic nerve and a leading cause of severe visual loss in the UK. Once patients have been diagnosed, they need regular monitoring at hospital eye services. Recent advances in technology mean patients with glaucoma can now monitor their disease at home. This could be more convenient for patients and potentially reduce costs and increase capacity for the NHS. However, it is uncertain whether self-monitoring would be acceptable or possible for patients with glaucoma. Objectives The objectives were to: identify which patients are most appropriate for home monitoring; understand views of key stakeholders (patients, clinicians, researchers) on whether home glaucoma monitoring is feasible and acceptable; develop a conceptual framework for the economic evaluation of home glaucoma monitoring; and explore the need for and provide evidence on the design of a future study to evaluate the clinical and cost-effectiveness of digital technologies for home monitoring of glaucoma. Design In-home Tracking of glaucoma: Reliability, Acceptability, and Cost (I-TRAC) was a multiphase mixed-methods feasibility study with key components informed by theoretical and conceptual frameworks. Setting Expert glaucoma specialists in the UK recruited through professional glaucoma societies; study site staff and patient participants recruited through three UK hospital eye services (England, Scotland, Northern Ireland); and UK research teams recruited though existing networks. Intervention Home tonometer that measures intraocular pressure and a tablet computer with a visual function application. Patients were asked to use the technology weekly for 12 weeks. Results Forty-two patients were recruited. Retention and completion of follow-up procedures was successful, with 95% (n = 40) completing the 3-month follow-up clinic visits. Adherence to the interventions was generally high [adherence to both devices (i.e. ≥ 80% adherence) was 55%]. Overall, patients and healthcare professionals were cautiously optimistic about the acceptability of digital technologies for home monitoring of patients with glaucoma. While most clinicians were supportive of the potential advantages glaucoma home monitoring could offer, concerns about the technologies (e.g. reliability and potential to miss disease progression) and how they would fit into routine care need to be addressed. Additionally, clarity is required on defining the ideal population for this intervention. Plans for how to evaluate value for money in a future study were also identified. However, the study also highlighted several unknowns relating to core components of a future evaluative study that require addressing before progression to a definitive effectiveness trial. Limitations The main limitation relates to our sample and its generalisability, for example, the over-representation of educated persons of white ethnicity who were generally experienced with technology and research motivated. Conclusions The In-home Tracking of glaucoma: Reliability, Acceptability, and Cost study has demonstrated 'cautious optimism' when considering patients' and healthcare professionals' views on the acceptability of digital technologies for home monitoring of patients with glaucoma. However, the study also highlighted several unknowns relating to the research question and design of a future evaluative study that require addressing before progression to a randomised controlled trial. Future work Further research is required to determine the appropriate population (i.e. low vs. high risk of progression) and further refine the intervention components and delivery for planning of future evaluation studies. Study registration This study is registered as Research Registry #6213. Funding This award was funded by the National Institute for Health and Care Research (NIHR) Health Technology Assessment programme (NIHR award ref: NIHR129248) and is published in full in Health Technology Assessment; Vol. 28, No. 44. See the NIHR Funding and Awards website for further award information.
Collapse
Affiliation(s)
- Carrie Stewart
- Health Services Research Unit, University of Aberdeen, Aberdeen, UK
| | - Hangjian Wu
- Health Economics Research Unit, University of Aberdeen, Aberdeen, UK
| | - Uma Alagappan
- Health Services Research Unit, University of Aberdeen, Aberdeen, UK
| | | | - Anthony J King
- Ophthalmology, Nottingham University Hospitals NHS Trust, Nottingham, UK
| | | | - Rodolfo Hernández
- Health Economics Research Unit, University of Aberdeen, Aberdeen, UK
| | | | | | - Nana Appiah
- Health Services Research Unit, University of Aberdeen, Aberdeen, UK
| | - Taylor Coffey
- Health Services Research Unit, University of Aberdeen, Aberdeen, UK
| | - Thenmalar Vadiveloo
- Health Services Research Unit, University of Aberdeen, Aberdeen, UK
- The Centre for Health Randomised Trials (CHaRT), University of Aberdeen, Aberdeen, UK
| | - Graeme MacLennan
- Health Services Research Unit, University of Aberdeen, Aberdeen, UK
- The Centre for Health Randomised Trials (CHaRT), University of Aberdeen, Aberdeen, UK
| | - Katie Gillies
- Health Services Research Unit, University of Aberdeen, Aberdeen, UK
| |
Collapse
|
4
|
Berneshawi AR, Shue A, Chang RT. Glaucoma Home Self-Testing Using VR Visual Fields and Rebound Tonometry Versus In-Clinic Perimetry and Goldmann Applanation Tonometry: A Pilot Study. Transl Vis Sci Technol 2024; 13:7. [PMID: 39102241 PMCID: PMC11309035 DOI: 10.1167/tvst.13.8.7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2023] [Accepted: 02/22/2024] [Indexed: 08/06/2024] Open
Abstract
Purpose This pilot study aimed to assess the feasibility, accuracy, and repeatability of unsupervised, at-home, multi-day glaucoma testing using the Olleyes VisuALL Virtual Reality Platform (VRP) and the iCare HOME handheld self-tonometer. Methods Participants were trained to use two U.S. Food and Drug Administration-registered or approved devices before conducting self-tests at home over 3 consecutive days. The iCare HOME intraocular pressure (IOP) measurements were collected four times daily per eye, and VRP visual field tests were performed once daily. The results were compared with one in-clinic Humphrey Field Analyzer (HFA) visual field test performed on the day of device training, iCare HOME measurements by the trainer, and the last five Goldmann applanation tonometer (GAT) results. Results Of 15 enrolled participants, nine of them (60%) completed the study. The six excluded participants could not self-measure using iCare HOME. There was significant correlation between the average mean deviation (MD) values of the at-home VRP tests and in-clinic HFA test (r2 = 0.8793, P < 0.001). Additionally, the average of the sensitivities in five of six Garway-Heath sectors were significantly correlated. VRP test duration was also shorter than in-clinic HFA testing (P < 0.001). Finally, at-home tonometry yielded statistically similar values compared to trainer-obtained iCare HOME values. The mean and range of at-home tonometry were also statistically similar to those for in-clinic GAT, but at-home tonometry demonstrated higher maximum IOP values (P = 0.0429). Conclusions Unsupervised, at-home, multi-day glaucoma testing using two devices resulted in the capture of higher maximum IOPs than in the clinic and good MD correlation of VRP with HFA. However, 40% of participants could not self-measure IOP using iCare HOME. Translational Relevance The study findings suggest that at-home remote glaucoma monitoring correlates with in-office testing and could provide additional information for glaucoma management, although patients had more difficulty with the iCare HOME than the VRP.
Collapse
Affiliation(s)
- Andrew R. Berneshawi
- Department of Ophthalmology, Stanford University School of Medicine, Stanford, CA, USA
| | - Ann Shue
- Department of Ophthalmology, Stanford University School of Medicine, Stanford, CA, USA
| | - Robert T. Chang
- Department of Ophthalmology, Stanford University School of Medicine, Stanford, CA, USA
| |
Collapse
|
5
|
Kobashi H. Evaluation of a new transpalpebral tonometer for self-measuring intraocular pressure. PLoS One 2024; 19:e0302568. [PMID: 38748752 PMCID: PMC11095731 DOI: 10.1371/journal.pone.0302568] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2023] [Accepted: 04/07/2024] [Indexed: 05/18/2024] Open
Abstract
PURPOSE We developed a novel transpalpebral self-tonometer called the TapEye tonometer (TET) based on palpation of the upper eyelid. Our goal was to evaluate a method for improving the accuracy of measuring intraocular pressure (IOP) through the eyelid. METHODS Participants underwent standardized training by technicians and were required to be able to use the TET for study inclusion. Subsequently, a noncontact tonometer and Goldmann applanation tonometer (GAT) were used. All participants were instructed to measure their IOPs using the three tonometers at baseline (visit 1) and at 1 month (visit 2). At visit 2, the corrected IOP value measured by the TET (c-TET) was calculated using the difference between the TET and GAT measurements obtained at visit 1. RESULTS No significant correlations were found between the TET and GAT measurements at any visit, but the correlation between the c-TET and GAT measurements at visit 2 was significant. The mean difference between the c-TET and GAT measurements was 0.4 ± 3.7 mmHg in the right eye and 0.5 ± 3.4 mmHg in the left eye. CONCLUSIONS After correcting the IOP based on the difference between the TET and GAT measurements at the initial visit, the corrected IOP value of the TET was correlated with that of the GAT at the second visit. The TET has the potential to address an unmet need by providing a tool for minimally invasive IOP measurements. TRIAL REGISTRATION Clinical trial registration number: jRCTs032220268.
Collapse
Affiliation(s)
- Hidenaga Kobashi
- Toneasy Inc., Tokyo, Japan
- Department of Ophthalmology, School of Medicine, Keio University, Tokyo, Japan
| |
Collapse
|
6
|
Kaya O, Akif Aydin M, Teymoori M, Kaan Erden O, Sadeghzadeh S, Dedeoglu UO, Demir S, Muhikanci O, Sahin A, Torun H, Dundar G, Yalcinkaya AD. A first-in-human pilot study of a novel electrically-passive metamaterial-inspired resonator-based ocular sensor embedded contact lens monitoring intraocular pressure fluctuations. Cont Lens Anterior Eye 2024; 47:102102. [PMID: 38114379 DOI: 10.1016/j.clae.2023.102102] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2023] [Revised: 11/29/2023] [Accepted: 12/03/2023] [Indexed: 12/21/2023]
Abstract
Glaucoma is a leading cause of blindness with no cure, but early treatment and effective monitoring can often slow the progression of the disease. Monitoring of glaucoma is based on the measurement of intra-ocular pressure (IOP) that is a physiological parameter related to the mechanical state and parameters of the eye. Conventionally, diagnosing and assessing the progression of glaucoma is based on the method of measuring IOP discretely at clinics. Recent studies have demonstrated the importance of continuously monitoring IOP for 24 h to elucidate the effect of circadian rhythm. In this work, a metamaterial-inspired electrically-passive sensor-embedded contact lens is presented to monitor the IOP fluctuations based on a first-in-human pilot study. The sensor inside the contact lens is an electrically passive, metamaterial-based resonator that can be measured using a wearable antenna patch. The system has been tested with six healthy volunteers during an experiment to induce deliberate IOP changes via water-loading and placing the individuals in supine position using a recliner seat. The initial data compared with tonometer measurements suggest that the system can be used to assess the variation of IOP continuously.
Collapse
Affiliation(s)
- Ozgur Kaya
- Glakolens, Bogazici Universitesi Teknopark 302, 34470 Istanbul, Turkiye
| | - M Akif Aydin
- Glakolens, Bogazici Universitesi Teknopark 302, 34470 Istanbul, Turkiye
| | - Morteza Teymoori
- Glakolens, Bogazici Universitesi Teknopark 302, 34470 Istanbul, Turkiye
| | - Oguz Kaan Erden
- Glakolens, Bogazici Universitesi Teknopark 302, 34470 Istanbul, Turkiye
| | | | - Ulas O Dedeoglu
- Glakolens, Bogazici Universitesi Teknopark 302, 34470 Istanbul, Turkiye
| | - Saibe Demir
- Glakolens, Bogazici Universitesi Teknopark 302, 34470 Istanbul, Turkiye
| | - Omer Muhikanci
- Glakolens, Bogazici Universitesi Teknopark 302, 34470 Istanbul, Turkiye
| | - Afsun Sahin
- Department of Ophthalmology, Koc University Medical School, Istanbul, Turkiye
| | - Hamdi Torun
- Faculty of Engineering & Environment, University of Northumbria, Newcastle Upon Tyne, NE1 8ST, UK.
| | - Gunhan Dundar
- Department of Electrical and Electronics Engineering, Bogazici University, Bebek 34342 Istanbul, Turkiye
| | - Arda D Yalcinkaya
- Department of Electrical and Electronics Engineering, Bogazici University, Bebek 34342 Istanbul, Turkiye
| |
Collapse
|
7
|
Shajiei TD, Wachtl J, Schuknecht A, Bachmann L, Kniestedt C. The Effect of Yoga on Intraocular Pressure Using the "iCare HOME2" Tonometer. Klin Monbl Augenheilkd 2024; 241:347-354. [PMID: 38653289 DOI: 10.1055/a-2200-3970] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/25/2024]
Abstract
BACKGROUND Various yoga positions may have an unfavorable impact on intraocular pressure (IOP) and may therefore be seen as a potential risk factor for the progression of glaucoma. The new "iCare HOME2" is a handheld self-tonometer for IOP measurements outside clinical settings. This is the first study to evaluate the immediate effect of common yoga postures on the IOP of healthy and glaucomatous eyes using the "iCare HOME2" self-tonometer and to compare the time of IOP recovery in both groups. METHODS This is a single-center, prospective, observational study including 25 healthy and 25 glaucoma patients performing the following yoga positions: "legs up" (Viparita Karani), "bend over" (Uttanasana), "plough pose" (Halasana), and the "down face dog" (Adho Mukha Svanasana) for 90 s each, with a 2-min break in between. IOP was measured with the "iCare HOME2" before, during, and after each position. RESULTS IOP significantly increased in all eyes in all positions (p < 0.05), showing no statistically significant difference between healthy or glaucomatous eyes (p > 0.05). The mean rise in IOP in healthy subjects was 1.6 mmHg (SD 1.42; p = 0.037), 14.4 mmHg (SD 4.48; p < 0.001), 7.5 mmHg (SD 4.21; p < 0.001), and 16.5 mmHg (SD 3.71; p < 0.001), whereas in glaucoma patients, IOP rose by 2.8 mmHg (SD 2.8; p = 0.017), 11.6 mmHg (SD 3.86; p < 0.001), 6.0 mmHg (SD 2.24; p < 0.001), and 15.1 mmHg (SD 4.44; p < 0.001) during the above listed yoga positions, repsectively. The highest increase in IOP was seen in the down face position, reaching mean IOP values above 31 mmHg in both study groups. IOP elevation was observed immediately after assuming the yoga position, with no significant change during the following 90 s of holding each pose (p > 0.05). All IOP values returned to baseline level in all individuals, with no significant difference between healthy and glaucoma participants. CONCLUSION Our data show that common yoga positions can lead to an acute IOP elevation of up to 31 mmHg in healthy as well as glaucoma eyes, with higher IOP values during head-down positions. Given that IOP peaks are a major risk factor for glaucomatous optic neuropathy, we generally advise glaucoma patients to carefully choose their yoga exercises. If and to what extent practicing yoga leads to glaucoma progression, however, remains unclear and warrants further research.
Collapse
Affiliation(s)
- Tania Darja Shajiei
- Ophthalmology, University Hospital Zurich, Zurich, Switzerland
- Ophthalmology, Talacker Augen Zentrum Zürich (TAZZ), Zurich, Switzerland
| | - Josephine Wachtl
- Ophthalmology, Talacker Augen Zentrum Zürich (TAZZ), Zurich, Switzerland
| | - Angelika Schuknecht
- Ophthalmology, University Hospital Zurich, Zurich, Switzerland
- Ophthalmology, Talacker Augen Zentrum Zürich (TAZZ), Zurich, Switzerland
| | - Lucas Bachmann
- Medignition Inc., Research Consultants, Zurich, Switzerland
| | | |
Collapse
|
8
|
Jo JJ, Pasquale LR. Recent developments of telemedicine in glaucoma. Curr Opin Ophthalmol 2024; 35:116-123. [PMID: 38295153 DOI: 10.1097/icu.0000000000001019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2024]
Abstract
PURPOSE OF REVIEW Telemedicine has an increasingly significant role in the fields of ophthalmology and glaucoma. This review covers recent advancements in the development and optimization of teleglaucoma techniques and applications. RECENT FINDINGS Glaucoma monitoring and diagnosis via remote tonometry, perimetry, and fundus imaging have become a possibility based on recent developments. Many applications work in combination with smart devices, virtual reality, and artificial intelligence and have been tested in patient populations against conventional "reference-standard" measurement tools, demonstrating promising results. Of note, there is still much progress to be made in teleglaucoma and telemedicine at large, such as accessibility to internet, broadband, and smart devices, application affordability, and reimbursement for remote services. However, continued development and optimization of these applications suggest that the implementation of remote monitoring will be a mainstay for glaucoma patient care. SUMMARY Especially since the beginning of the COVID-19 pandemic, remote patient care has taken on an important role in medicine and ophthalmology. Remote versions of tonometry, perimetry, and fundus imaging may allow for a more patient-centered and accessible future for glaucoma care.
Collapse
Affiliation(s)
- Jason J Jo
- Department of Medical Education
- Department of Ophthalmology, Icahn School of Medicine at Mount Sinai, New York, New York, USA
| | - Louis R Pasquale
- Department of Medical Education
- Department of Ophthalmology, Icahn School of Medicine at Mount Sinai, New York, New York, USA
| |
Collapse
|
9
|
Kratz A, Zbidat R, Kishner R, Cohen M, Shalata W, Goldberg I. Assessment of the iCare HOME2, a New Intraocular Pressure Self-Measurement Tonometer. J Glaucoma 2023; 32:926-929. [PMID: 37671544 DOI: 10.1097/ijg.0000000000002298] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2023] [Accepted: 08/13/2023] [Indexed: 09/07/2023]
Abstract
PRCIS The iCare HOME2 tonometer generally can be considered reliable for most eyes and clinical settings, although it may produce slightly overestimated or underestimated intraocular pressure (IOP) readings in thicker and thinner corneas, respectively. PURPOSE To evaluate the accuracy, correlation, and analysis of differences in IOP measurements between the gold standard Goldmann applanation tonometer (GAT) and the new, self-measurement iCare HOME2 tonometer (icare). PATIENTS AND METHODS In this retrospective study, patients were randomly selected from those who attended a routine examination in our clinic. After a complete ocular examination, each patient's IOP was measured and recorded with GAT and iCare HOME2. Central corneal thickness was measured. Eyes with any corneal morbidity were excluded. Pearson correlation coefficient was used to determine the correlation between paired IOP measurements. Bland-Altman plots were graphed for the analysis of differences in IOP between the instruments. RESULTS One hundred thirty-five eyes of 70 patients were included in the study. The mean IOP measured with GAT was 16.3 ± 6.5 mm Hg (range: 3-56). The mean IOP measured with iCare HOME2 was 16.5 ± 7.3 mm Hg (range: 3-55), ( P = 0.47). A strong, significant positive correlation was found for paired IOP measurements by the 2 instruments ( r = 0.94; P < 0.0001). A small systematic proportional bias was seen for the paired IOP measurements, meaning that with higher IOPs the iCare HOME2 yielded higher IOP readings than GAT, but this difference was clinically insignificant. The instrument underestimated IOPs with corneas thinner than 522 µm, whereas it overestimated IOPs when corneas were thicker than this. CONCLUSION The iCare HOME2 could be a reliable tonometer for most eyes and clinical settings. Central corneal thickness measurement is recommended in patients who use the instrument.
Collapse
Affiliation(s)
- Assaf Kratz
- Department of Ophthalmology, Soroka University Medical Center, Faculty of Health Sciences, Ben-Gurion University of the Negev, Beer-Sheva, Israel
- Faculty of Health Sciences, Ben Gurion University of the Negev, Beer Sheva, Israel
| | - Rabia Zbidat
- Department of Ophthalmology, Soroka University Medical Center, Faculty of Health Sciences, Ben-Gurion University of the Negev, Beer-Sheva, Israel
| | - Rina Kishner
- Department of Ophthalmology, Soroka University Medical Center, Faculty of Health Sciences, Ben-Gurion University of the Negev, Beer-Sheva, Israel
| | - Michal Cohen
- Faculty of Health Sciences, Ben Gurion University of the Negev, Beer Sheva, Israel
| | - Walid Shalata
- Department of Ophthalmology, Soroka University Medical Center, Faculty of Health Sciences, Ben-Gurion University of the Negev, Beer-Sheva, Israel
| | - Ivan Goldberg
- Glaucoma Unit, Sydney Eye Hospital, Sydney, NSW, Australia
- Discipline of Ophthalmology, Faculty of Medicine and Health, University of Sydney, Sydney, NSW, Australia
| |
Collapse
|
10
|
Nayak A, Ramesh SV, Kuzhuppilly NIR, Pai VH, Chaitanya A. Performance of home-based self-tonometry (iCare HOME (TA022)) for measuring intraocular pressure among healthy and glaucoma patients. F1000Res 2023; 12:128. [PMID: 38894819 PMCID: PMC11184277 DOI: 10.12688/f1000research.123104.2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 09/18/2023] [Indexed: 06/21/2024] Open
Abstract
Introduction: The purpose of this study was to compare iCare HOME (TA022) with Goldmann applanation tonometer and to evaluate the self-tonometry measurements among the Indian population. Methods: Eligible patients underwent iCare HOME training through guided demonstration (verbal, pictorial, video) and practised self-tonometry measures using iCare HOME. Certification for independent iCare HOME measure was provided if first iCare HOME intraocular pressure (IOP) measurement fell within ± 5 mmHg of Goldmann applanation tonometer (GAT) measurement which was measured by the trained clinician (principal investigator). Certified participants underwent simulated home self-tonometry measurements using iCare HOME, and agreement with GAT IOP measurements was assessed. Results: Seven of 83 participants (8.43%) failed to complete the study due to difficulty in performing the task, leading to non-certification. Patients who could use the iCare HOME had a mean age of 53 ± 15.55years (53% males; 46% females). Only one in 12 subjects did not qualify to use iCare HOME. The overall mean difference between iCare HOME and GAT was 0.83 mmHg (95%, 3.92 and -2.25). At various pressure ranges, 7-16 mmHg, 17-23 mmHg and >23 mmHg, the mean difference between iCare HOME and GAT was 1.22 mmHg (95%, 4.32 and -1.86), 0.77 mmHg (95%,3.69 and -2.19), -0.11 mmHg (95%, 2.52 and -2.74) respectively. The intra-class correlation coefficient of the iCare HOME device was 0.997(95% CI,0.995-0.998). Conclusions: Patients were able to perform self- tonometry using iCare HOME with good reliability and safety. iCare HOME can be used to address the issue of difficulty in acquiring frequent and diurnal IOP measurements by patients doing self-tonometry from home.
Collapse
Affiliation(s)
- Anush Nayak
- Department of Allied Health Sciences,Faculty of Life & Allied Health Sciences(FLAHS), Ramaiah University of Applied Sciences, Bangalore, Karnataka, 560054, India
- Department of Optometry, Manipal College of Health Professions (MCHP), Manipal Academy of Higher Education (MAHE), Manipal, Udupi (Dist), Karnataka, 576104, India
| | - S Ve Ramesh
- Department of Optometry, Manipal College of Health Professions (MCHP), Manipal Academy of Higher Education (MAHE), Manipal, Udupi (Dist), Karnataka, 576104, India
| | - Neetha I R Kuzhuppilly
- Department of Ophthalmology, Kasturba Medical College, Manipal, Manipal Academy of Higher Education (MAHE), Manipal, Udupi (Dist), Karnataka, 576104, India
| | - Vijaya H Pai
- Department of Ophthalmology, Kasturba Medical College, Manipal, Manipal Academy of Higher Education (MAHE), Manipal, Udupi (Dist), Karnataka, 576104, India
| | - Aditya Chaitanya
- Department of Optometry, Manipal College of Health Professions (MCHP), Manipal Academy of Higher Education (MAHE), Manipal, Udupi (Dist), Karnataka, 576104, India
| |
Collapse
|
11
|
Kadambi SV, Aishwarya M, Leelavathy C, George R, Balekudaru S, Lingam V, Baskaran M. Clinical utility, feasibility of home tonometry using iCare HOME by glaucoma patients. Indian J Ophthalmol 2023; 71:2727-2732. [PMID: 37417112 PMCID: PMC10491071 DOI: 10.4103/ijo.ijo_147_23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2023] [Revised: 05/21/2023] [Accepted: 05/21/2023] [Indexed: 07/08/2023] Open
Abstract
Purpose To determine agreement between diurnal variation testing (DVT) of intraocular pressure (IOP) with Goldmann applanation tonometer (GAT) and iCare HOME (IH) by an optometrist (OP) and home monitoring by participants (PT). Methods Patients (18-80 years) with glaucoma and suspects were enrolled. IH IOP and GAT were taken by an OP at 2 h intervals from 8 AM to 4 PM on Day 1 and PT between 6 AM and 9 PM, for the next 2 days. IOP, date, and time were viewed via iCare LINK software. Results: In total, 72.9. ( 51/70) PT trained were able to take reliable readings. One hundred two eyes (51 patients, age 53 ± 16 yrs) were analyzed. Correlation between optometrist (OP) and participants (PT) was strong and positive {IH OP-IH PT- r = 0.90, p-0.0001;IH PT-GAT- r = 0.79, p-0.0001}. Agreement by Bland Altman plots was limited {IH OP-IH PT mean 0.1 mmHg (95% LOA -5.3 to 5.5), IH PT-GAT 2.2 mmHg (-5.7 to 10.1)}. Intraclass correlation coefficient for IH OP-IH PT was 1.18 (95% CI 1.37-1.09). Intradevice {0.95 (95% CI 0.94-0.97)} and interrater repeatability {0.91 (0.79-0.96)} were good. 37% of eyes had a synchronous peak on GAT and IH during the day DVT. Conclusion Home tonometry by iCare HOME is easy, feasible, but due to limited agreement cannot substitute GAT DVT.
Collapse
Affiliation(s)
- Sujatha V Kadambi
- Smt Jadhavbai Nathmal Singhvee Glaucoma Services, Sankara Nethralaya, Medical Research Foundation, Chennai, Tamil Nadu, India
| | - M Aishwarya
- Department of Optometry, Sankara Nethralaya, Medical Research Foundation, Chennai, Tamil Nadu, India
| | - C Leelavathy
- Department of Optometry, Sankara Nethralaya, Medical Research Foundation, Chennai, Tamil Nadu, India
| | - Ronnie George
- Smt Jadhavbai Nathmal Singhvee Glaucoma Services, Sankara Nethralaya, Medical Research Foundation, Chennai, Tamil Nadu, India
| | - Shantha Balekudaru
- Smt Jadhavbai Nathmal Singhvee Glaucoma Services, Sankara Nethralaya, Medical Research Foundation, Chennai, Tamil Nadu, India
| | - Vijaya Lingam
- Smt Jadhavbai Nathmal Singhvee Glaucoma Services, Sankara Nethralaya, Medical Research Foundation, Chennai, Tamil Nadu, India
| | - Mani Baskaran
- Smt Jadhavbai Nathmal Singhvee Glaucoma Services, Sankara Nethralaya, Medical Research Foundation, Chennai, Tamil Nadu, India
| |
Collapse
|
12
|
Porwal AC, Shrishrimal M, Punamia RP, Mathew BC. Assessment of intraocular pressure measurement between Goldman applanation tonometer, rebound tonometer, non-contact tonometer, and its correlation with central corneal thickness. Indian J Ophthalmol 2023; 71:1927-1931. [PMID: 37203058 PMCID: PMC10391371 DOI: 10.4103/ijo.ijo_1982_22] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/20/2023] Open
Abstract
Purpose To compare readings of intraocular pressure (IOP) taken with the Goldmann applanation tonometer (GAT), the non-contact tonometer (NCT), and the rebound tonometer (RBT), and to compare their correlation with central corneal thickness (CCT). Methods This was a prospective, cross-sectional, observational study to which patients above 18 years of age were enrolled. A total of 400 eyes of 200 non-glaucomatous patients underwent IOP recordings using the GAT, NCT, and RBT, and CCT was also noted. Informed consent of the patients was taken. The IOP readings taken via the three methods were compared and correlated with CCT. Paired t test was used to compare the two devices. Simple and multivariate linear regression analyses were used to study the relationship between factors. A P value less than 0.05 was considered significant. Correlation was determined using the Pearson correlation coefficient, and a Bland-Altman graph was plotted. Results Mean IOP measured by the NCT was 15.65 ± 2.80 mmHg, by the RBT was 14.23 ± 3.05 mmHg, and by the GAT was 14.69 ± 2.97 mmHg. The mean CCT was 510.61 ± 33.83 microns. The difference between mean IOP recorded by the NCT and that by the RBT was 1.41 ± 2.39 mmHg, between the NCT and GAT was 0.95 ± 2.03 mmHg, and between the GAT and RBT was 0.45 ± 2.22 mmHg. The difference between the IOP values was statistically significant (P < 0.005). All tonometers showed a statistically significant correlation with CCT, but it was observed that the NCT had a stronger correlation (0.4037). Conclusion The IOP readings taken by all the three methods were comparable; however, RBT values were closer to GAT values. CCT did influence the IOP values, and this should be kept in mind while evaluating.
Collapse
Affiliation(s)
- Amit C Porwal
- Senior Consultant Cataract and Head Glaucoma Services, Department of Cataract and Glaucoma, Choithram Netralaya, Indore, Madhya Pradesh, India
| | - Meghna Shrishrimal
- Department of Community Ophthalmology, Choithram Netralaya, Indore, Madhya Pradesh, India
| | - Ravin P Punamia
- Department of Ophthalmology, Choithram Netralaya, Indore, Madhya Pradesh, India
| | | |
Collapse
|
13
|
Shigemoto Y, Hasebe Y, Kitamura K, Fukuda Y, Sakamoto M, Matsubara M, Minaguchi S, Kashiwagi K. Repeated Measurements Are Necessary for Evaluating Accurate Diurnal Rhythm Using a Self-Intraocular Pressure Measurement Device. J Clin Med 2023; 12:jcm12072460. [PMID: 37048542 PMCID: PMC10094971 DOI: 10.3390/jcm12072460] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2023] [Revised: 03/02/2023] [Accepted: 03/20/2023] [Indexed: 04/14/2023] Open
Abstract
PURPOSE To investigate how many tests need to be performed to adequately assess intraocular pressure (IOP) diurnal change using a self-measuring rebound tonometer among glaucoma patients. SUBJECTS AND METHODS Adult patients with primary open-angle glaucoma were included. IOP was measured in the morning (6 AM to 9 AM), afternoon (12 PM to 3 PM), and at night (6 PM to 9 PM) for seven consecutive days. Twenty-four (7 males and 17 females, mean age 59.5 ± 11.0 years) patients who successfully measured IOP at least three times per day during the correct time periods for four days were subjected to analysis. RESULTS The IOP rhythm was significantly greater on the first day of measurement (6.6 ± 3.6 mmHg) than that averaged during subsequent days (4.4 ± 2.2 mmHg). The time of the highest and lowest IOP measurements on the first day of IOP measurement and during the entire measurement period coincided in 72.9% and 64.6% of cases, respectively. The concordance rate of the highest IOP time between the whole measurement period and each measurement day was less than 60%. CONCLUSION The diurnal IOP rhythm measured by the patients themselves was not consistent, and multiple days of measurements may be necessary to correctly assess diurnal IOP rhythm.
Collapse
Affiliation(s)
- Yumi Shigemoto
- Department of Ophthalmology, Faculty of Medicine, University of Yamanashi, Yamanashi 409-3898, Japan
| | - Yuka Hasebe
- Department of Ophthalmology, Faculty of Medicine, University of Yamanashi, Yamanashi 409-3898, Japan
| | - Kazuyoshi Kitamura
- Department of Ophthalmology, Faculty of Medicine, University of Yamanashi, Yamanashi 409-3898, Japan
| | - Yoshiko Fukuda
- Department of Ophthalmology, Faculty of Medicine, University of Yamanashi, Yamanashi 409-3898, Japan
| | - Masako Sakamoto
- Department of Ophthalmology, Faculty of Medicine, University of Yamanashi, Yamanashi 409-3898, Japan
| | - Mio Matsubara
- Department of Ophthalmology, Faculty of Medicine, University of Yamanashi, Yamanashi 409-3898, Japan
| | - Shinya Minaguchi
- Department of Ophthalmology, Faculty of Medicine, University of Yamanashi, Yamanashi 409-3898, Japan
| | - Kenji Kashiwagi
- Department of Ophthalmology, Faculty of Medicine, University of Yamanashi, Yamanashi 409-3898, Japan
| |
Collapse
|
14
|
Quérat L, Chen E. Impact of self-tonometry on glaucoma treatment decision. Acta Ophthalmol 2023; 101:e246-e251. [PMID: 36147012 DOI: 10.1111/aos.15256] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2022] [Revised: 08/17/2022] [Accepted: 09/03/2022] [Indexed: 11/26/2022]
Abstract
PURPOSE The aim of this study was to examine the impact of self-tonometry on clinicians' decision in glaucoma treatment. MATERIALS AND METHODS Medical records of 133 patients who had performed self-tonometry using iCare® Home between January and December 2019 were retrospectively reviewed. Inclusion criteria were as follows: age over 18 years, all types of glaucoma, as well as ocular hypertension and glaucoma suspect, compliance with tonometer manufacturer's recommendations and monitoring over at least 2 days. The data consisted of age, gender, diagnosis, visual field index, rate of progression and type of treatment pre- and post-intraocular pressure (IOP) phasing. The following IOP measurements were used to calculate the mean and maximum IOP, and range over each day and consecutive days: Goldmann applanation tonometry (GAT) measurements from referral and training visits and iCare® Home measurements made by the trainers and the patients themselves. A total of 90 patients were included. RESULTS Clinicians were satisfied with the actual treatment in 54.4% of the cases. There was a statistically significant difference between the clinicians' decision to maintain same treatment or to escalate therapy for all the mean and maximum IOPs measured on each single day and over a 2- or 3-day period (p < 0.002). CONCLUSION Our results suggest that the presence of high IOP values obtained with self-tonometry supports an intensification of glaucoma treatment. Self-tonometry provides clinicians with an important complement for clinical decision-making, and under- or over-treatment may be avoided for the benefit of patients.
Collapse
Affiliation(s)
- Laurence Quérat
- Division of Eye and Vision, Department of Clinical Neuroscience, Karolinska Institute, Stockholm, Sweden.,Department of Anterior Segment Disorders, Glaucoma, Neuro-Ophthalmology and Oculoplastics, St. Erik Eye Hospital, Solna, Sweden
| | - Enping Chen
- Division of Eye and Vision, Department of Clinical Neuroscience, Karolinska Institute, Stockholm, Sweden.,Department of Anterior Segment Disorders, Glaucoma, Neuro-Ophthalmology and Oculoplastics, St. Erik Eye Hospital, Solna, Sweden
| |
Collapse
|
15
|
EYEMATE-SC Trial: Twelve-Month Safety, Performance, and Accuracy of a Suprachoroidal Sensor for Telemetric Measurement of Intraocular Pressure. Ophthalmology 2023; 130:304-312. [PMID: 36202141 DOI: 10.1016/j.ophtha.2022.09.021] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2022] [Revised: 09/19/2022] [Accepted: 09/20/2022] [Indexed: 11/07/2022] Open
Abstract
PURPOSE Measuring and controlling intraocular pressure (IOP) provide the foundation for glaucoma treatment. Self-tonometry has been proposed as an alternative to measure IOP throughout the entire day better. The novel EYEMATE-SC sensor (Implandata) is implanted in the suprachoroidal space to enable contactless continual IOP monitoring. The aim of the present study was to investigate the 1-year safety, performance, and accuracy of the EYEMATE-SC in patients with primary open-angle glaucoma undergoing simultaneous nonpenetrating glaucoma surgery (NPGS). DESIGN Prospective, multicenter, open-label, single-arm, interventional clinical trial. PARTICIPANTS Twenty-four eyes of 24 patients with primary open-angle glaucoma who were due to undergo NPGS (canaloplasty or deep sclerectomy). METHODS An EYEMATE-SC sensor was implanted during NPGS. Goldmann applanation tonometry (GAT) measurements were compared with the sensors' IOP measurements at all postoperative visits through 12 months. MAIN OUTCOME MEASURES Device position and adverse events. RESULTS Fifteen eyes underwent canaloplasty, and 9 underwent deep sclerectomy. Successful implantation of the sensor was achieved in all eyes with no reported intraoperative difficulties. Through the 12-month follow-up, no device migration, dislocation, or serious device-related complications were recorded. A total of 536 EYEMATE-SC measurements were pairwise included in the IOP agreement analysis. The overall mean difference between GAT and EYEMATE-SC measurements was 0.8 mmHg (95% confidence interval [CI] of the limits of agreement [LoA], -5.1 to 6.7 mmHg). The agreement gradually improved, and from 3 months after surgery until the end of the follow-up, the mean difference was -0.2 mmHg (95% CI of LoA, -4.6 to 4.2 mmHg) over a total of 264 EYEMATE-SC measurements, and 100% of measurements were within ±5 mmHg of GAT. CONCLUSIONS The EYEMATE-SC sensor was safe and well tolerated through 12 months. Moreover, it allowed accurate, continuous IOP monitoring. FINANCIAL DISCLOSURE(S) Proprietary or commercial disclosure may be found after the references.
Collapse
|
16
|
Yaïci R, Geerling G. [Tonometry: Review and Perspectives]. Klin Monbl Augenheilkd 2023. [PMID: 36827998 DOI: 10.1055/a-2022-0624] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/26/2023]
Abstract
Reliable and repeated IOP measurement are essential in the diagnosis and treatment of glaucoma. In this second part, the other contact tonometry and non-contact tonometry are presented. The clinical value of the different methods and the value of multimodality in tonometry will be discussed based on a review of the literature, and the latest innovations with telemetric IOP sensors will be introduced.
Collapse
|
17
|
Abstract
ZusammenfassungIn 2. Teil des Beitrags werden die sonstigen Kontakttonometer und die Nonkontakttonometrie präsentiert. Es wird anhand einer Revue der Literatur über den klinischen Wert der verschiedenen Methoden und den Wert der Multimodalität in der Tonometrie diskutiert; ferner werden die letzten Innovationen mit den telemetrischen IOD-Sensoren eingeführt.
Collapse
|
18
|
Quérat L, Chen E. iCare® Home vs Goldmann applanation tonometry: Agreement of methods and comparison of inter-observer variation at a tertiary eye centre. Eur J Ophthalmol 2023; 33:312-318. [PMID: 35505614 PMCID: PMC9834317 DOI: 10.1177/11206721221099252] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
Abstract
Purpose: To investigate whether the inter-observer variation is similar between the Goldmann applanation tonometer used by healthcare staff and the iCare® Home tonometer used by glaucoma patients, volunteers and healthcare staff. Methods: Sixty-one participants were recruited to the study, including 24 glaucoma patients. Seven participants were excluded. For each participant, intraocular pressure (IOP) was measured on the same occasion by two different healthcare staff using GAT as well as by a healthcare staff and the participant using the iCare® Home tonometer. Results: Seventy-two per cent of iCare® measurements were within 3 mmHg of the GAT measurements. There was a statistically significant difference between the trainers' measurements made with iCare® Home and those made with GAT (p < 0.001), as well as between the GAT measurements made by trainers and those made by extra personnel (p = 0.017). The strongest correlation was between iCare® Home participants' and trainers' measurements (0.934). The correlation between different users with GAT was lower (0.769). The inter-user agreement was excellent for iCare® Home users (95% CI 0.93, ranging from 0.880 to 0.959) and moderate for GAT users (95% CI 0.741, ranging from 0.558 to 0.849). Conclusion: Our study found that tonometry with iCare® Home has similar or less inter-user variation compared with GAT.
Collapse
Affiliation(s)
- Laurence Quérat
- Laurence Quérat, Department of Anterior Segment Disorders, St Erik Eye Hospital, Eugeniavägen 12, 171 64 Solna, Sweden.
| | | |
Collapse
|
19
|
Levin AM, McGlumphy EJ, Chaya CJ, Wirostko BM, Johnson TV. The utility of home tonometry for peri-interventional decision-making in glaucoma surgery: Case series. Am J Ophthalmol Case Rep 2022; 28:101689. [PMID: 36247209 PMCID: PMC9562449 DOI: 10.1016/j.ajoc.2022.101689] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2022] [Revised: 08/15/2022] [Accepted: 08/22/2022] [Indexed: 11/16/2022] Open
Abstract
Purpose To describe twelve cases in which home intraocular pressure (IOP) monitoring complimented clinical decision-making in glaucoma management. Observations Home IOP monitoring elucidated peaks and amplitudes of variation that were not captured by in-clinic IOP measurements during the pre- or post-interventional period. Conclusions & Importance Home monitoring can establish pre-treatment IOP patterns that are not evident during in-clinic measurements. Home monitoring can also demonstrate response to treatment more quickly than in-clinic monitoring, and provide more information about nyctohemoral fluctuations than is ascertained by in-clinic tonometry.
Collapse
Affiliation(s)
- Ariana M. Levin
- Moran Eye Center, University of Utah, Salt Lake City, UT, USA
| | - Elyse J. McGlumphy
- Glaucoma Center of Excellence, Wilmer Eye Institute, Johns Hopkins University School of Medicine, Baltimore, MD, USA
| | - Craig J. Chaya
- Moran Eye Center, University of Utah, Salt Lake City, UT, USA
| | | | - Thomas V. Johnson
- Glaucoma Center of Excellence, Wilmer Eye Institute, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- Corresponding author.
| |
Collapse
|
20
|
Hou C, Pu C. Patients' awareness of their intraocular pressure. Clin Exp Ophthalmol 2022; 50:1103-1105. [DOI: 10.1111/ceo.14137] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2022] [Revised: 07/03/2022] [Accepted: 07/09/2022] [Indexed: 11/28/2022]
Affiliation(s)
- Chiun‐Ho Hou
- Institute of Public Health School of Medicine, National Yang Ming Chiao Tung University Taipei Taiwan
- Department of Ophthalmology Linkou Chang Gung Memorial Hospital Taoyuan Taiwan
- Department of Medicine College of Medicine, Chang Gung University Taoyuan Taiwan
- Department of Ophthalmology National Taiwan University Hospital Taipei Taiwan
| | - Christy Pu
- Institute of Public Health School of Medicine, National Yang Ming Chiao Tung University Taipei Taiwan
| |
Collapse
|
21
|
Ogle JJ, Soo Hoo WC, Chua CH, Yip LWL. Accuracy and Reliability of Self-measured Intraocular Pressure in Glaucoma Patients Using the iCare HOME Tonometer. J Glaucoma 2021; 30:1027-1032. [PMID: 34628422 DOI: 10.1097/ijg.0000000000001945] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2021] [Accepted: 09/10/2021] [Indexed: 11/26/2022]
Abstract
PRCIS The iCare HOME tonometer is a useful tool which can be used by patients for fairly accurate and reliable self-measurement of intraocular pressure (IOP). PURPOSE The aim was to compare the accuracy of IOP measurements of trained glaucoma patients using the iCare HOME tonometer before and after a week of self-monitoring at home and study the repeatability of patient measurements done at home. MATERIALS AND METHODS A total of 40 glaucoma patients had IOPs measured using the Goldmann applanation tonometer and the iCare HOME. Patients were trained to use the iCare HOME and measured their IOP twice daily over a loan period of 7 days. Bland-Altman analysis was used to assess agreement between Goldmann applanation tonometer and iCare HOME readings. Intraclass correlation coefficient compared inter-rater reliability of iCare HOME measurements, and test-retest variability for the patient's readings over the 7-day period were analyzed. A 5-point Likert scale questionnaire was used to assess the patient's experience with the device. RESULTS Up to 32 patients (80%) were able to obtain IOP readings within 3 mm Hg of the glaucoma nurse clinician's readings at the preloan visit, and up to 36 patients (90%) at the postloan visit. Good inter-rater reliability was observed between iCare HOME measurements by the glaucoma nurse clinician and patients. At the postloan visit, inter-rater reliability was good for right eye readings and excellent for left eye readings. No distinct trend in test-retest variability was identified over the 7-day period. 65% of patients agreed the device was easy to use and 89% would recommend the device to other glaucoma patients. CONCLUSION Patients trained to use the iCare HOME device can do so with fair accuracy compared with trainers with accuracy improving within 1 week of usage.
Collapse
Affiliation(s)
- Jeanne J Ogle
- Department of Ophthalmology, Tan Tock Seng Hospital, National Healthcare Group Eye Institute
| | - Wai Cheng Soo Hoo
- Department of Ophthalmology, Tan Tock Seng Hospital, National Healthcare Group Eye Institute
| | - Chun Hau Chua
- Department of Ophthalmology, Tan Tock Seng Hospital, National Healthcare Group Eye Institute
| | - Leonard W L Yip
- Department of Ophthalmology, Tan Tock Seng Hospital, National Healthcare Group Eye Institute
- Lee Kong Chian School of Medicine, Nanyang Technological University, Singapore, Singapore
| |
Collapse
|
22
|
McGlumphy EJ, Mihailovic A, Ramulu PY, Johnson TV. Home Self-tonometry Trials Compared with Clinic Tonometry in Patients with Glaucoma. Ophthalmol Glaucoma 2021; 4:569-580. [PMID: 33845191 PMCID: PMC8501148 DOI: 10.1016/j.ogla.2021.03.017] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2021] [Revised: 03/27/2021] [Accepted: 03/29/2021] [Indexed: 11/19/2022]
Abstract
PURPOSE This study examined characteristics of intraocular pressure (IOP) as measured during home tonometry in comparison with in-clinic tonometry in patients with glaucoma. DESIGN Retrospective cross-sectional study of glaucoma patients who completed 1 week of self-tonometry at a single academic center. PARTICIPANTS Patients with glaucoma who completed home tonometry trials with the iCare HOME tonometer (iCare USA) for any reason. METHODS Home IOP measurements were compared with in-clinic tonometry performed during the 5 visits preceding home tonometry. Maximum daily IOP was correlated to time of day. Generalized estimating equations were used to evaluate patient characteristics and clinic-derived variables that predicted differences between home and clinic IOP. MAIN OUTCOME MEASURES IOP mean, maximum, minimum, range, standard deviation and coefficient of variation were compared between clinic and home tonometry. IOP mean daily maximum (MDM) and mean daily range were calculated to describe recurrent IOP spiking. RESULTS A total of 107 eyes from 61 patients were analyzed. Mean age was 63.2 years (standard deviation [SD], 14.0 years) and 59.0% were women. Mean clinic and home IOPs were 14.5 mmHg (SD, 4.7 mmHg) and 13.6 mmHg (SD, 5.1 mmHg). Home tonometry identified significantly higher maximum IOP, lower minimum IOP, and greater IOP range than clinic tonometry (P < 0.001). Maximum daily IOP occurred outside of clinic hours (8 am-5 pm) on 50% of days assessed and occurred between 4:30 am and 8 am on 24% of days. Mean daily maximum IOP exceeded maximum clinic IOP in 44% of patients and exceeded target IOP by 3 mmHg, 5 mmHg, or 10 mmHg in 31%, 15%, and 6% of patients, respectively. Patient characteristics that predicted significant deviations between MDM and mean clinic IOP or target IOP in multivariate models included younger age, male gender, and absence of prior filtering surgery. CONCLUSIONS Self-tonometry provides IOP data that supplements in-clinic tonometry and would not be detectable over daytime in-clinic diurnal curves. A subset of patients in whom home tonometry was ordered by their glaucoma clinician because of suspicion of occult IOP elevation demonstrated reproducible IOP elevation outside of the clinic setting. Such patients tended to be younger and male and not to have undergone previous filtering surgery.
Collapse
Affiliation(s)
- Elyse J McGlumphy
- Glaucoma Center of Excellence, Wilmer Eye Institute, Johns Hopkins University School of Medicine, Baltimore, Maryland
| | - Aleksandra Mihailovic
- Glaucoma Center of Excellence, Wilmer Eye Institute, Johns Hopkins University School of Medicine, Baltimore, Maryland
| | - Pradeep Y Ramulu
- Glaucoma Center of Excellence, Wilmer Eye Institute, Johns Hopkins University School of Medicine, Baltimore, Maryland
| | - Thomas V Johnson
- Glaucoma Center of Excellence, Wilmer Eye Institute, Johns Hopkins University School of Medicine, Baltimore, Maryland.
| |
Collapse
|
23
|
Tong J, Huang J, Kalloniatis M, Coroneo M, Zangerl B. Clinical Trial: Diurnal IOP Fluctuations in Glaucoma Using Latanoprost and Timolol with Self-Tonometry. Optom Vis Sci 2021; 98:901-913. [PMID: 34393206 DOI: 10.1097/opx.0000000000001751] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
SIGNIFICANCE Assessment of treatment efficacy via comparison with a target IOP is fundamental in monitoring patients with open-angle glaucoma and ocular hypertension. This article highlights that diurnal IOP fluctuations obtained using self-tonometry may more accurately reflect IOP responses to therapy. PURPOSE This study aimed to investigate fluctuations in diurnal IOP measurements in patients with open-angle glaucoma and ocular hypertension treated with latanoprost 0.005% and timolol 0.25%. METHODS In this crossover treatment trial, 14 participants performed self-tonometry with iCare HOME 4 times daily for (1) 1 week using latanoprost, (2) 4 weeks using no medications, and (3) 2 weeks using timolol. Daily peak IOPs, IOP fluctuations, and mean IOPs from different treatments were compared on an individual basis. Treatment efficacy between medications was assessed by comparing mean percentage IOP reductions with latanoprost and timolol across participants. In addition, effects of age, years since commencing latanoprost, sex, and diagnosis were investigated, and peak IOP times were compared with assess impacts on diurnal profiles. RESULTS Between individuals, IOP responses ranged from reductions in peak IOPs, IOP fluctuations, and mean IOPs on both medications to no change in any parameter and medication. IOP fluctuations showed greater mean percentage reductions than did peak and mean IOPs (χ2 = 16.51, P = .002). There were significant associations between years since commencing latanoprost and peak and mean IOP responses on timolol (r = 0.69, P = .007), and sex and relative reductions in IOP fluctuations on both medications (P = .03). There were no differences in peak IOP times between treatment conditions. CONCLUSIONS Despite variability in IOP responses to latanoprost and timolol, IOP fluctuation with self-tonometry was more consistent in evaluating target IOP, reflecting its importance in ascertaining true IOP response to topical therapies. These findings may impact clinical decision making based on target IOP criteria in patients on topical therapy.
Collapse
Affiliation(s)
| | | | | | - Minas Coroneo
- Department of Ophthalmology, University of New South Wales at Prince of Wales Hospital, Sydney, New South Wales, Australia
| | | |
Collapse
|
24
|
The Utility of iCare HOME Tonometry for Detection of Therapy-Related Intraocular Pressure Changes in Glaucoma and Ocular Hypertension. Ophthalmol Glaucoma 2021; 5:85-93. [PMID: 34082179 DOI: 10.1016/j.ogla.2021.05.007] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2021] [Revised: 04/30/2021] [Accepted: 05/21/2021] [Indexed: 11/21/2022]
Abstract
PURPOSE To assess whether iCare HOME rebound tonometry can detect therapy-related changes during self-monitoring of intraocular pressure (IOP). DESIGN Prospective clinical trial. PARTICIPANTS A total of 43 eyes (n = 27 subjects) with open-angle glaucoma or ocular hypertension were enrolled during standard-of-care clinic visits. Participants were grouped into control eyes managed on stable therapy (n = 18 eyes) or therapy change eyes undergoing selective laser trabeculoplasty (SLT, n = 8 eyes), initiating topical therapy (n = 8 eyes), or adding a second medication to existing monotherapy (n = 9 eyes). METHODS Subjects recorded IOP 4 times daily for 1 week using iCare HOME tonometry. Upon tonometer return, subjects underwent SLT or new medication start; an additional week of iCare HOME measurements was collected after 4 to 6 weeks. Control subjects recorded an additional week of measurements after 6 weeks. Measurements were grouped into 4 time periods (5-10 am, 10 am to 3 pm, 3-8 pm, 8 pm to 1 am). Goldmann applanation tonometry (GAT) was performed at each study visit for comparison. MAIN OUTCOME MEASURES Detection of therapy response defined as an IOP reduction of ≥20%. RESULTS For eyes that demonstrated a therapy response by GAT (n = 11), iCare HOME detected a therapy response in 90.9% of eyes in ≥1 time period and 45.5% of eyes in all 4 time periods. In eyes without a GAT-measured therapy response (n = 14), iCare HOME detected a response for 71.4% (n = 10) of eyes in ≥1 time period and for 7.1% of eyes (n = 1) at all 4 time periods. In treatment eyes, intraday and interday average minimum and maximum IOP, as well as interday IOP range, were significantly reduced after therapy without a significant change in intraday IOP range. Control group eyes did not demonstrate a significant change in average IOP minimum, maximum, or range between study weeks. CONCLUSIONS Home tonometry with iCare HOME reliably detects therapy-related IOP changes in patients with glaucoma and ocular hypertension. Treatment responses correlated well with in-office GAT and may detect treatment responses missed by GAT. Intraocular pressure measurements via home tonometry provide additional clinical information regarding intraday and interday IOP fluctuation beyond standard of care in office GAT measurements. The iCare HOME is a valuable tool to monitor therapeutic efficacy in patients with glaucoma.
Collapse
|
25
|
Levin AM, Vezina D, Wirostko BM. Home-Based Intraocular Pressure Measurements: Tracing a Parallel with Out-of-Office Blood Pressure Measurement. Ophthalmol Glaucoma 2021; 4:235-237. [PMID: 34030825 DOI: 10.1016/j.ogla.2021.03.001] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2021] [Revised: 02/23/2021] [Accepted: 03/02/2021] [Indexed: 01/19/2023]
|
26
|
Tan BH, Young A, Bianchi E, Brown L, Tatham AJ. Fluctuation in Blood Pressure and Intraocular Pressure in Normal Tension Glaucoma Using Ambulatory Monitoring. J Glaucoma 2021; 30:304-311. [PMID: 33394843 DOI: 10.1097/ijg.0000000000001768] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2020] [Accepted: 11/25/2020] [Indexed: 11/25/2022]
Abstract
PRCIS Ambulatory blood pressure (BP) and intraocular pressure (IOP) monitoring of patients with normal tension glaucoma (NTG) revealed features of vascular dysregulation including hypertension, blunted nocturnal BP dipping, and morning BP surge. PURPOSE The aim was to examine ambulatory fluctuations in IOP and BP in patients with NTG. METHODS A prospective study of 45 participants with NTG and 10 controls. All participants had a comprehensive ophthalmological examination followed by glaucoma medication washout. Patients using systemic antihypertensives were excluded. IOP and BP were recorded using home monitoring over 48 hours using a self-rebound tonometer and ambulatory blood pressure monitor. BP was recorded every 30 minutes by day and every 60 minutes overnight. IOP was recorded at 09:00, 11:00, 13:00, 16:00, 20:00, and 04:00. RESULTS Participants with NTG had a median mean deviation (MD) of -4.66 dB (interquartile range: -7.16 to -2.81 dB) in the worse eye. Among those with glaucoma, 18 of 45 (40%) had normal nocturnal BP dipping, 24 (53%) blunted dipping and 3 (6.7%) exaggerated dipping. Each 10 mm Hg lower minimum sleeping systolic BP was associated with a 0.9 dB (95% confidence interval: 0.1-1.6 dB) worse MD. Sixteen of 45 participants with glaucoma (35.6%) and 1 of 10 controls (10%) were found to have systemic hypertension on ambulatory blood pressure monitoring and 32 of those with glaucoma (71%) had a surge in morning BP, compared with 5 controls (50%). There was no difference in MD between patients with normal, exaggerated and blunted dipping (P=0.813). CONCLUSIONS Though glaucoma has been associated with exaggerated nocturnal BP dipping, we found a higher proportion of patients had systemic hypertension, blunted nocturnal BP dipping, and a morning BP surge, measures also associated with vascular dysregulation.
Collapse
Affiliation(s)
- Boo Hui Tan
- Princess Alexandra Eye Pavilion
- University of Edinburgh, Edinburgh, UK
| | - Alexandra Young
- Princess Alexandra Eye Pavilion
- University of Edinburgh, Edinburgh, UK
| | - Eleonora Bianchi
- Princess Alexandra Eye Pavilion
- University of Edinburgh, Edinburgh, UK
| | - Lyndsay Brown
- Princess Alexandra Eye Pavilion
- University of Edinburgh, Edinburgh, UK
| | - Andrew J Tatham
- Princess Alexandra Eye Pavilion
- University of Edinburgh, Edinburgh, UK
| |
Collapse
|
27
|
Rosenfeld E, Rabina G, Barequet D, Mimouni M, Fischer N, Kurtz S. Role of home monitoring with iCare ONE rebound tonometer in glaucoma patients management. Int J Ophthalmol 2021; 14:405-408. [PMID: 33747817 DOI: 10.18240/ijo.2021.03.12] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2020] [Accepted: 07/20/2020] [Indexed: 11/23/2022] Open
Abstract
AIM To evaluate intraocular pressure (IOP) measurements and fluctuations using the iCare ONE rebound tonometer (RT-ONE), during home monitoring, in diagnosed and suspected glaucoma patients. METHODS A retrospective case series of consecutive patients with known glaucoma or glaucoma suspects who were followed-up and treated between January 2016 and January 2017. The study included 80 eyes of 40 patients with a mean age of 59.1±14.6y (range, 24-78). All patients have undergone 4-5d of IOP home monitoring with RT-ONE at morning, noon, afternoon, and night time. RESULTS Baseline mean IOP, as measured in the clinic (8 a.m.-12 p.m.), was 17.4±5.1 mm Hg, compared to RT-ONE home monitoring mean IOP of 15.6±4.1 mm Hg (P=0.002). Mean IOP was significantly lower at noon, afternoon and night times compared to clinic measured IOP and morning measurements (P=0.005). IOP peak measured during home monitoring was significantly higher compared to the clinic measured IOP (21.3±5.6 mm Hg and 17.4±5.1 mm Hg, P<0.001). IOP peaks during home monitoring demonstrated a majority of 47 peaks during morning measurements, compared to 23 at noon, 19 at afternoon and only 12 at night (P<0.001). The home monitoring results led to treatment modification of 44 eyes (55%), treatment regime was insufficient for 40 (50%) eyes. CONCLUSION Home monitoring IOP with RT-ONE can provide good assessment of mean IOP, IOP fluctuations and peaks throughout the hours of the day, which lead to an accurate treatment for glaucoma patients.
Collapse
Affiliation(s)
- Eldar Rosenfeld
- Department of Ophthalmology, Tel Aviv Sourasky Medical Center, Affiliated to the Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv 64239, Israel
| | - Gilad Rabina
- Department of Ophthalmology, Tel Aviv Sourasky Medical Center, Affiliated to the Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv 64239, Israel
| | - Dana Barequet
- Department of Ophthalmology, Tel Aviv Sourasky Medical Center, Affiliated to the Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv 64239, Israel
| | - Michael Mimouni
- Department of Ophthalmology, Rambam Health Care Campus, Affiliated to Ruth Rappaport Faculty of Medicine, Technion-Israel Institute of Technology, Haifa 3109601, Israel
| | - Naomi Fischer
- Department of Ophthalmology, Tel Aviv Sourasky Medical Center, Affiliated to the Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv 64239, Israel
| | - Shimon Kurtz
- Department of Ophthalmology, Tel Aviv Sourasky Medical Center, Affiliated to the Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv 64239, Israel
| |
Collapse
|
28
|
Abstract
Technological advances provide a number of options for glaucoma monitoring outside the office setting, including home-based tonometry and perimetry. This has the potential to revolutionize management of this chronic disease, improve access to care, and enhance patient engagement. Here, we provide an overview of existing technologies for home-based glaucoma monitoring. We also discuss areas for future research and the potential applications of these technologies to telemedicine, which has been brought to the forefront during the ongoing COVID-19 pandemic.
Collapse
Affiliation(s)
- Inas F Aboobakar
- Department of Ophthalmology , Massachusetts Eye and Ear, Harvard Medical School, Boston, MA, USA
| | - David S Friedman
- Department of Ophthalmology , Massachusetts Eye and Ear, Harvard Medical School, Boston, MA, USA
| |
Collapse
|
29
|
Abstract
PURPOSE OF REVIEW The current article reviews the impact of the coronavirus disease 2019 (COVID-19) pandemic on the delivery of ophthalmic, and specifically, glaucoma care. RECENT FINDINGS Literature from the review period includes case series demonstrating the presence of severe acute respiratory syndrome coronavirus 2 RNA in the conjunctival secretions of patients with laboratory-confirmed COVID-19. The global ophthalmology community published reports outlining the enhanced infection control measures undertaken by different institutions around the world to mitigate transmission of the novel coronavirus. Telemedicine has been increasingly implemented in glaucoma practices to reduce in-office patient volume. New data regarding the efficacy and feasibility of tools for home monitoring of intraocular pressure, virtual visual field testing, and remote disc photography are reviewed. SUMMARY COVID-19 has posed a global public health threat due to the severity of its contagion and associated morbidity and mortality. Glaucoma specialists have responded to the pandemic with innovative modifications to reduce viral transmission and optimize patient and staff safety in the office and operating room. The role of teleglaucoma has expanded and will continue to evolve as remote diagnostic devices undergo further refinement and validation.
Collapse
Affiliation(s)
- Kateki Vinod
- Department of Ophthalmology, Icahn School of Medicine at Mount Sinai
- Department of Ophthalmology, New York Eye and Ear Infirmary of Mount Sinai, New York, New York, USA
| | - Paul A Sidoti
- Department of Ophthalmology, Icahn School of Medicine at Mount Sinai
- Department of Ophthalmology, New York Eye and Ear Infirmary of Mount Sinai, New York, New York, USA
| |
Collapse
|
30
|
Jones PR, Campbell P, Callaghan T, Jones L, Asfaw DS, Edgar DF, Crabb DP. Glaucoma Home Monitoring Using a Tablet-Based Visual Field Test (Eyecatcher): An Assessment of Accuracy and Adherence Over 6 Months. Am J Ophthalmol 2021; 223:42-52. [PMID: 32882222 PMCID: PMC7462567 DOI: 10.1016/j.ajo.2020.08.039] [Citation(s) in RCA: 31] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2020] [Revised: 08/24/2020] [Accepted: 08/24/2020] [Indexed: 01/14/2023]
Abstract
Purpose To assess accuracy and adherence of visual field (VF) home monitoring in a pilot sample of patients with glaucoma. Design Prospective longitudinal feasibility and reliability study. Methods Twenty adults (median 71 years) with an established diagnosis of glaucoma were issued a tablet perimeter (Eyecatcher) and were asked to perform 1 VF home assessment per eye, per month, for 6 months (12 tests total). Before and after home monitoring, 2 VF assessments were performed in clinic using standard automated perimetry (4 tests total, per eye). Results All 20 participants could perform monthly home monitoring, though 1 participant stopped after 4 months (adherence: 98% of tests). There was good concordance between VFs measured at home and in the clinic (r = 0.94, P < .001). In 21 of 236 tests (9%), mean deviation deviated by more than ±3 dB from the median. Many of these anomalous tests could be identified by applying machine learning techniques to recordings from the tablets' front-facing camera (area under the receiver operating characteristic curve = 0.78). Adding home-monitoring data to 2 standard automated perimetry tests made 6 months apart reduced measurement error (between-test measurement variability) in 97% of eyes, with mean absolute error more than halving in 90% of eyes. Median test duration was 4.5 minutes (quartiles: 3.9-5.2 minutes). Substantial variations in ambient illumination had no observable effect on VF measurements (r = 0.07, P = .320). Conclusions Home monitoring of VFs is viable for some patients and may provide clinically useful data.
Collapse
Affiliation(s)
- Pete R Jones
- Division of Optometry and Visual Sciences, School of Health Sciences, City, University of London, London, UK
| | - Peter Campbell
- Division of Optometry and Visual Sciences, School of Health Sciences, City, University of London, London, UK; Department of Ophthalmology, Guy's and St Thomas' NHS Foundation Trust, London, UK.
| | - Tamsin Callaghan
- Division of Optometry and Visual Sciences, School of Health Sciences, City, University of London, London, UK
| | - Lee Jones
- Division of Optometry and Visual Sciences, School of Health Sciences, City, University of London, London, UK
| | - Daniel S Asfaw
- Division of Optometry and Visual Sciences, School of Health Sciences, City, University of London, London, UK
| | - David F Edgar
- Division of Optometry and Visual Sciences, School of Health Sciences, City, University of London, London, UK
| | - David P Crabb
- Division of Optometry and Visual Sciences, School of Health Sciences, City, University of London, London, UK
| |
Collapse
|
31
|
Gedde SJ, Vinod K, Wright MM, Muir KW, Lind JT, Chen PP, Li T, Mansberger SL. Primary Open-Angle Glaucoma Preferred Practice Pattern®. Ophthalmology 2021; 128:P71-P150. [DOI: 10.1016/j.ophtha.2020.10.022] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2020] [Accepted: 10/20/2020] [Indexed: 12/17/2022] Open
|
32
|
Liu J, De Francesco T, Schlenker M, Ahmed II. Icare Home Tonometer: A Review of Characteristics and Clinical Utility. Clin Ophthalmol 2020; 14:4031-4045. [PMID: 33262568 PMCID: PMC7695605 DOI: 10.2147/opth.s284844] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2020] [Accepted: 10/30/2020] [Indexed: 12/03/2022] Open
Abstract
The Icare HOME (TA022, Icare Oy, Vanda, Finland) is rebound tonometer recently approved by the US Food and Drug Administration in March 2017 designed for self-measurement of intraocular pressure (IOP). IOP remains a major modifiable risk factor for glaucoma progression; however, IOP measurements typically occur through single office measurements on Goldmann applanation tonometry (GAT) and do not always reveal the complete picture of patient’s IOP patterns and daily fluctuations, which are important for accurate diagnosis and evaluation. Numerous studies have now compared the efficacy of the Icare HOME to that of GAT. The objective of this article is to review the existing literature surrounding the Icare HOME tonometer and its efficacy as a self-tonometer in comparison to GAT. The available literature has shown promising results in its accuracy of measuring IOP but suggests cautious usage in patients with central corneal thicknesses or IOP ranges that are outside of a certain range. This article will also provide details and example cases for when the Icare HOME may be most clinically useful.
Collapse
Affiliation(s)
- John Liu
- Department of Ophthalmology and Vision Sciences, University of Toronto, Toronto, Ontario, Canada.,Prism Eye Institute, Oakville, Ontario, Canada
| | - Ticiana De Francesco
- Department of Ophthalmology and Vision Sciences, University of Toronto, Toronto, Ontario, Canada.,Prism Eye Institute, Oakville, Ontario, Canada
| | - Matthew Schlenker
- Department of Ophthalmology and Vision Sciences, University of Toronto, Toronto, Ontario, Canada.,Prism Eye Institute, Oakville, Ontario, Canada
| | - Iqbal Ike Ahmed
- Department of Ophthalmology and Vision Sciences, University of Toronto, Toronto, Ontario, Canada.,Prism Eye Institute, Oakville, Ontario, Canada
| |
Collapse
|
33
|
Osmers J, Hoppe O, Strzalkowska A, Strzalkowski P, Patzkó Á, Arnold S, Sorg M, Fischer A. Results of First In Vivo Trial of an Acoustic Self-Tonometer. Transl Vis Sci Technol 2020; 9:18. [PMID: 32879774 PMCID: PMC7442865 DOI: 10.1167/tvst.9.9.18] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2020] [Accepted: 05/14/2020] [Indexed: 11/24/2022] Open
Abstract
Purpose Glaucoma is the world's most common cause of irreversible blindness, which makes early diagnosis, with the goal of preserving vision, essential. The current medical intervention is to reduce intraocular pressure (IOP) to slow down progression of the disease. The main goal of this study was to test a novel handheld acoustic self-tonometer on humans. Methods A sound pressure pulse generated by a loudspeaker causes the eye to vibrate. A pressure chamber is placed on the human orbit to form a coupled system comprised of the patient's eye, the enclosed air, and the loudspeaker. A displacement sensor in front of the loudspeaker membrane allows the dynamic behavior of the entire system to be detected. Results For this clinical trial series, a prototype of the acoustic self-tonometer principle was applied. The resulting membrane oscillation data showed sensitivity of patient IOP, but direct allocation of the measured damping and frequency to the IOP was not significant. For this reason, an artificial neural network was used to find relationships among the subjects’ biometric eye parameters in combination with the self-tonometer data for the IOP reference. An expanded measurement uncertainty (kp = 2) equal to 6.53 mm Hg was determined for the self-tonometer in a Bland–Altman analysis using Goldmann applanation tonometer reference measurements. Conclusions The usability and success rate of producing valid measurement values with the device during self-measurements by test subjects was nearly 92%. The cross-sensitivities observed require compensation in a possible redesign phase to reduce the measurement uncertainty by at least 25% to the maximum of 5 mm Hg required to seek medical device approval. Translational Relevance Building on successful laboratory experiments with pig eyes, this article reports the results of testing the acoustic tonometer on humans.
Collapse
Affiliation(s)
- Jan Osmers
- University of Bremen, Bremen Institute for Metrology, Automation and Quality Science (BIMAQ), Bremen, Germany
| | - Oskar Hoppe
- University of Bremen, Bremen Institute for Metrology, Automation and Quality Science (BIMAQ), Bremen, Germany
| | - Alicja Strzalkowska
- Department of Ophthalmology, University Hospital Würzburg, Würzburg, Germany
| | - Piotr Strzalkowski
- Department of Ophthalmology, University Hospital Würzburg, Würzburg, Germany
| | - Ágnes Patzkó
- Department of Ophthalmology, University Hospital Würzburg, Würzburg, Germany
| | | | - Michael Sorg
- University of Bremen, Bremen Institute for Metrology, Automation and Quality Science (BIMAQ), Bremen, Germany
| | - Andreas Fischer
- University of Bremen, Bremen Institute for Metrology, Automation and Quality Science (BIMAQ), Bremen, Germany
| |
Collapse
|
34
|
Rojas CD, Reed DM, Moroi SE. Usefulness of Icare Home in Telemedicine Workflow to Detect Real-World Intraocular Pressure Response to Glaucoma Medication Change. Ophthalmol Glaucoma 2020; 3:403-405. [PMID: 32980045 DOI: 10.1016/j.ogla.2020.04.017] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2020] [Revised: 04/24/2020] [Accepted: 04/29/2020] [Indexed: 10/24/2022]
Affiliation(s)
- Carin D Rojas
- Department of Ophthalmology and Visual Sciences, University of Michigan, Ann Arbor, Michigan
| | - David M Reed
- Department of Ophthalmology and Visual Sciences, University of Michigan, Ann Arbor, Michigan
| | - Sayoko E Moroi
- Department of Ophthalmology and Visual Sciences, University of Michigan, Ann Arbor, Michigan; Department of Ophthalmology & Visual Sciences, The Ohio State University Wexner Medical Center, Columbus, Ohio.
| |
Collapse
|
35
|
McGarva E, Farr J, Dabasia P, Lawrenson JG, Murdoch IE. Initial experience in self-monitoring of intraocular pressure. Eur J Ophthalmol 2020; 31:1326-1332. [PMID: 32340488 PMCID: PMC8358569 DOI: 10.1177/1120672120920217] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Background/aims Diurnal variation in intraocular pressure (IOP) is a routine assessment in glaucoma management. Providing patients the opportunity to perform self-tonometry might empower them and free hospital resource. We previously demonstrated that 74% of patients can use the Icare® HOME tonometer. This study further explores Icare® HOME patient self-monitoring. Methods Patients were trained by standard protocol to use the Icare® HOME rebound tonometer. Patient self-tonometry was compared to Goldmann applanation tonometry (GAT) over one clinical day. Following this, each patient was instructed to undertake further data collection that evening and over the subsequent two days. Results Eighteen patients (35 eyes) participated. Good agreement was demonstrated between GAT and Icare® HOME for IOPs up to 15 mm Hg. Above this IOP the Icare® tended to over-read, largely explained by 2 patients with corneal thickness >600 um. The mean peak IOP during ‘clinic hours’ phasing was 16.7 mm Hg and 18.5 mm Hg (p = 0.24) over three days. An average range of 5.0, 7.0 and 9.8 mm Hg was shown during single day clinic, single day home and three day home phasing respectively (p =<0.001). The range of IOP was lower in eyes with prior trabeculectomy (6.1 mm Hg vs 12.2 mm Hg). All patients undertook one reading in the early morning at home with an average of 4.8 readings during, and 3.1 readings after office hours. Conclusions This small study shows that self-tonometry is feasible. The findings from home phasing demonstrated higher peak and trough IOPs, providing additional clinical information. Home phasing is a viable alternative. The cost-effectiveness of this approach has yet to be addressed.
Collapse
Affiliation(s)
- Emily McGarva
- Moorfields Eye Hospital NHS Foundation Trust, London, UK
| | - Jane Farr
- Moorfields Eye Hospital NHS Foundation Trust, London, UK
| | - Priya Dabasia
- Division of Optometry and Visual Sciences, City, University of London, London, UK
| | - John G Lawrenson
- Division of Optometry and Visual Sciences, City, University of London, London, UK.,UCL Institute of Ophthalmology, London, UK
| | - Ian E Murdoch
- Moorfields Eye Hospital NHS Foundation Trust, London, UK.,UCL Institute of Ophthalmology, London, UK
| |
Collapse
|
36
|
Abstract
SIGNIFICANCE Icare HOME rebound tonometry is increasingly adopted into clinical practice for IOP phasing of glaucoma patients and suspects. Because of measurement differences with applanation tonometry and diurnal fluctuations, interpretation of the IOP measured with Icare HOME phasing can be challenging. PURPOSE The purpose of this study was to use a large patient cohort to develop a practical, analytical tool for interpreting Icare HOME measurements with respect to applanation pressure. METHODS IOP measurements using the Icare HOME and an applanation tonometer were taken prospectively in 498 consecutive patients. Bland-Altman, frequency distribution, and linear regression analysis were applied to determine measurement differences. A novel criterion, Threshold Icare HOME IOP, was developed to assist identification of elevation above target applanation pressure, considering the expected diurnal variation and measurement variability. RESULTS Icare HOME tended to underestimate applanation tonometry (mean bias, -1.7 mmHg; 95% limits of agreement, -7.0 to +3.6). Overall, differences were within ±3 mmHg in 71.5% and ±5 mmHg in 92% of patients. Based on the novel criterion developed, Icare HOME measurements that exceed target applanation pressure by 6 mmHg or greater are generally outside the 95% limit of expected observations. CONCLUSIONS The Threshold Icare HOME IOP is a novel and practical criterion that can assist clinicians in their interpretation of Icare HOME phasing measurements with respect to target applanation pressures. Elevation above the expected thresholds may prompt closer monitoring or even modifications to glaucoma management.
Collapse
|
37
|
Awadalla MS, Qassim A, Hassall M, Nguyen TT, Landers J, Craig JE. Using Icare HOME tonometry for follow‐up of patients with open‐angle glaucoma before and after selective laser trabeculoplasty. Clin Exp Ophthalmol 2020; 48:328-333. [DOI: 10.1111/ceo.13686] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2019] [Revised: 10/29/2019] [Accepted: 11/15/2019] [Indexed: 11/30/2022]
Affiliation(s)
- Mona S. Awadalla
- Department of OphthalmologyFlinders University Adelaide South Australia Australia
| | - Ayub Qassim
- Department of OphthalmologyFlinders University Adelaide South Australia Australia
| | - Mark Hassall
- Department of OphthalmologyFlinders University Adelaide South Australia Australia
| | - Thi T. Nguyen
- Department of OphthalmologyFlinders University Adelaide South Australia Australia
| | - John Landers
- Department of OphthalmologyFlinders University Adelaide South Australia Australia
| | - Jamie E. Craig
- Department of OphthalmologyFlinders University Adelaide South Australia Australia
| |
Collapse
|
38
|
Nasrollahi A, Rizzo P. Modeling a new dynamic approach to measure intraocular pressure with solitary waves. J Mech Behav Biomed Mater 2020; 103:103534. [DOI: 10.1016/j.jmbbm.2019.103534] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2019] [Revised: 10/21/2019] [Accepted: 11/12/2019] [Indexed: 10/25/2022]
|
39
|
Rebound Self-tonometry Acquisition Time and Ease of Use Evaluated by Newly Trained Optometry Students and Optometrists. Optom Vis Sci 2020; 97:94-100. [DOI: 10.1097/opx.0000000000001481] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
|
40
|
Che Hamzah J, Daka Q, Azuara-Blanco A. Home monitoring for glaucoma. Eye (Lond) 2019; 34:155-160. [PMID: 31772381 DOI: 10.1038/s41433-019-0669-7] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2019] [Revised: 09/25/2019] [Accepted: 10/09/2019] [Indexed: 11/09/2022] Open
Abstract
Glaucoma services are overwhelmed and struggling to accommodate current demand. Reducing the need for hospital based services would improve our ability to see those most at risk of vision loss, which could both reduce demand and improve patient outcomes. Digital technologies that provide opportunities for home monitoring of glaucoma progression have potential to contribute to solve these challenges and, potentially, improve glaucoma care. This article will review the literatures of well-established technologies that support home monitoring for glaucoma, specifically home tonometry (with rebound tonometry) and perimetry with Moorfields Motion Displacement Test and Melbourne Rapid Field.
Collapse
Affiliation(s)
- Jemaima Che Hamzah
- Department of Ophthalmology, Faculty of Medicine, Universiti Kebangsaan Malaysia, Kuala Lumpur, Malaysia
| | - Qëndresë Daka
- Department of Pathophysiology, Medical Faculty, University of Prishtina, Prishtinë, Kosovo
| | - Augusto Azuara-Blanco
- Centre for Public Health, School of Medicine, Dentistry and Biomedical Sciences, Queen's University Belfast, Belfast, UK.
| |
Collapse
|
41
|
De Moraes CG, Mansouri K, Liebmann JM, Ritch R. Association Between 24-Hour Intraocular Pressure Monitored With Contact Lens Sensor and Visual Field Progression in Older Adults With Glaucoma. JAMA Ophthalmol 2019; 136:779-785. [PMID: 29800011 DOI: 10.1001/jamaophthalmol.2018.1746] [Citation(s) in RCA: 46] [Impact Index Per Article: 9.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Abstract
Importance Twenty-four-hour intraocular pressure (IOP) patterns may provide more information regarding rates of visual field progression than office-hour measurements. However, little is known about the added value of 24-hour monitoring when stratifying glaucoma risk based on rates of progression. Objective To test the hypothesis that 24-hour IOP-related patterns recorded with a contact lens sensor (CLS) correlate with prior rates of visual field progression. Design, Setting, and Participants A multicenter, retrospective cohort study was conducted at 50 ophthalmology care centers in 13 countries. Participants included 445 patients (445 eyes) with treated, manifest open-angle glaucoma. The study was conducted from November 8, 1999, to September 17, 2016. Interventions Twenty-four-hour recordings of IOP-related patterns were prospectively collected with a CLS system. Retrospective visual field data of patients who underwent at least 3 prior reliable visual field tests were examined. Main Outcomes and Measures Association between CLS variables and rates of visual field mean deviation (MD) change. Results Of the 445 patients included, 238 (53.5%) were women and 394 (88.5%) were white. The mean (SD) age and MD values at the time of CLS recording were 68.9 (11.2) years and -9.0 (7.0) dB. The mean rate of MD change was -0.46 (0.5) dB/y in 5.2 (3) years of follow-up. After adjusting for baseline MD severity, age, and treatment, the following CLS variables were associated with fast visual field progression: mean peak ratio while awake (β = -0.021; 95% CI, -0.04 to -0.003), number of long peaks during sleep (β = 0.036; 95% CI, 0.005 to 0.067), night bursts ocular pulse frequency SD (β = 0.027; 95% CI, 0.004 to 0.051), and night bursts ocular pulse amplitude SD (β = 19.739; 95% CI, 1.333 to 38.145). Regression models including CLS variables had better fit than Goldmann IOP when testing the association with rates of progression. Conclusions and Relevance Results of this study indicate that 24-hour CLS recordings may be associated with prior rates of visual field progression of glaucoma. This association appears to be better than Goldmann mean IOP measured multiple times during office hours. Therefore, the CLS may be useful to assess the risk of future functional loss, even in situations when insufficient historical visual field information is available.
Collapse
Affiliation(s)
- Carlos Gustavo De Moraes
- Bernard and Shirlee Brown Glaucoma Research Laboratory, Edward S. Harkness Eye Institute, Columbia University Medical Center, New York, New York
| | - Kaweh Mansouri
- Glaucoma Research Center, Montchoisi Clinic, Swiss Vision Network, Lausanne, Switzerland.,Department of Ophthalmology, University of Colorado, Denver, Colorado
| | - Jeffrey M Liebmann
- Bernard and Shirlee Brown Glaucoma Research Laboratory, Edward S. Harkness Eye Institute, Columbia University Medical Center, New York, New York
| | - Robert Ritch
- Einhorn Clinical Research Center, New York Eye and Ear Infirmary of Mount Sinai, New York, New York
| | | |
Collapse
|
42
|
Beck D, Tatham AJ. Self-monitoring of intraocular pressure in glaucoma. EXPERT REVIEW OF OPHTHALMOLOGY 2019. [DOI: 10.1080/17469899.2019.1652093] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Affiliation(s)
- Daniel Beck
- Princess Alexandra Eye Pavilion, Department of Ophthalmology, University of Edinburgh, Edinburgh, UK
| | - Andrew J. Tatham
- Princess Alexandra Eye Pavilion, Department of Ophthalmology, University of Edinburgh, Edinburgh, UK
| |
Collapse
|
43
|
Cvenkel B, Atanasovska Velkovska M. Self-monitoring of intraocular pressure using Icare HOME tonometry in clinical practice. Clin Ophthalmol 2019; 13:841-847. [PMID: 31190727 PMCID: PMC6520593 DOI: 10.2147/opth.s198846] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2018] [Accepted: 04/04/2019] [Indexed: 12/30/2022] Open
Abstract
Purpose: To determine the value of self-monitoring of diurnal intraocular pressure (IOP) by Icare Home rebound tonometer in patients with glaucoma and ocular hypertension. Methods: Patients with open-angle glaucoma or ocular hypertension, controlled IOP at office visits, and at least 3 years of follow-up in the glaucoma clinic were included. Progression of glaucoma was based on medical records and defined by documented structural and/or visual field change. Patients were trained to correctly perform self-tonometry and instructed to measure diurnal IOP in a home setting for 3 days. IOP characteristics (mean, peak IOP, fluctuation of IOP as range, and SD of IOP) were documented and compared between the progressive and stable eyes. Results: Ninety-four patients (50 females) with a mean (SD) age of 57.1 (14.7) years were included. Among the 94 eyes from 94 subjects, 72 (76.6%) eyes had primary open-angle glaucoma, ten (10.6%) had pigmentary glaucoma, four (4.3%) had exfoliative glaucoma, and eight (8.5%) eyes had ocular hypertension. Thirty-six eyes showed progression and 58 eyes were stable. Patients with progression were older than those with stable disease (mean (SD) 65.8 (8.4) years vs 51.7 (15.3) years, P<0.001). The progression group had higher average IOP (mean (SD) 15.8 (4.0) mmHg vs 13.3 (3.7) mmHg, P=0.002), peak IOP (mean (SD) 21.8 (5.8) mmHg vs 18.6 (4.8) mmHg, P=0.01), and greater IOP fluctuation range (mean (SD) 11.6 (4.8) vs 9.1 (3.5) mmHg, P=0.011) compared to non-progression group. Conclusion: Self-monitoring of IOP using Icare Home tonometry provides more complete data on variability of IOP to assist in the management of glaucoma.
Collapse
Affiliation(s)
- Barbara Cvenkel
- Department of Ophthalmology, University Medical Centre Ljubljana, Ljubljana, Slovenia.,Medical Faculty, University of Ljubljana, Ljubljana, Slovenia
| | | |
Collapse
|
44
|
Cvenkel B, Velkovska MA, Jordanova VD. Self-measurement with Icare HOME tonometer, patients' feasibility and acceptability. Eur J Ophthalmol 2019; 30:258-263. [PMID: 30632407 DOI: 10.1177/1120672118823124] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
PURPOSE To evaluate and compare the accuracy of self-measurement of intraocular pressure using Icare Home rebound tonometer with Goldmann applanation tonometer and assess acceptability of self-tonometry in patients with glaucoma and ocular hypertension. METHODS In the study, 117 subjects were trained to use Icare Home for self-measurement. Icare Home tonometer readings were compared with Goldmann applanation tonometer, including one eye per patient. Agreement between the two methods of measurement was evaluated by Bland and Altmann analysis. Questionnaire was used to evaluate patients' perception of self-tonometry. RESULTS One hundred and three out of 117 patients (88%) were able to measure their own intraocular pressure and 96 (82%) fulfilled the requirements for certification. The mean (SD) difference Goldmann applanation tonometer minus Icare Home was 1.2 (2.4) mmHg (95% limits of agreement, -3.4 to 5.9 mmHg). The magnitude of bias between the two methods depended on central corneal thickness, with greater bias at central corneal thickness <500 µm. In 65 out of 96 subjects (67.7%), Icare Home results were within 2 mmHg of the Goldmann applanation tonometer. Seventy-three out of 93 (78.5%) felt that self-tonometry was easy to use and 75 patients (80.6%) responded that they would use the device at home. CONCLUSION Icare Home tonometry tends to slightly underestimate intraocular pressure compared to Goldmann applanation tonometer. Most patients were able to perform self-tonometry and found it acceptable for home use. Measurements using rebound self-tonometry could improve the quality of intraocular pressure data and optimize treatment regimen.
Collapse
Affiliation(s)
- Barbara Cvenkel
- Department of Ophthalmology, University Medical Centre Ljubljana, Ljubljana, Slovenia.,University of Ljubljana, Ljubljana, Slovenia
| | | | - Vesna Dimovska Jordanova
- University Eye Clinic, Skopje, Republic of Macedonia.,Saints Cyril and Methodius University of Skopje, Skopje, Republic of Macedonia
| |
Collapse
|
45
|
Abstract
This review describes some of the most recent advances in the development and application of new technologies for detecting and managing glaucoma, including imaging, visual function testing, and tonometry. The widespread availability of mobile technology in the developing world is improving health care delivery, for example, with smartphones and mobile applications that allow patient data to be assessed remotely by health care providers.
Collapse
Affiliation(s)
- Ignacio Rodriguez-Una
- Glaucoma Department, Instituto Oftalmologico Fernandez-Vega, University of Oviedo, Oviedo, Spain
| | | |
Collapse
|
46
|
Quigley HA. 21st century glaucoma care. Eye (Lond) 2018; 33:254-260. [PMID: 30305707 DOI: 10.1038/s41433-018-0227-8] [Citation(s) in RCA: 41] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2018] [Revised: 07/31/2018] [Accepted: 08/07/2018] [Indexed: 11/09/2022] Open
Abstract
Glaucoma care has evolved dramatically over the past generation, with changes that have incorporated new technology and improved understanding of the disease process. A major need is to construct a useful definition of glaucomatous optic neuropathy that can be used to compare data across clinical research studies. The treatment of glaucoma should now be based on achievement of a goal target for intraocular pressure, unique to each patient. Adherence with eye drop treatment is far from ideal and can be improved using reminder systems. Sustained delivery of glaucoma medication is on the horizon. New surgical approaches to glaucoma are being actively studied but have not as yet found their place in its care, with rigorous testing against present treatments needed.
Collapse
Affiliation(s)
- Harry A Quigley
- Department of Ophthalmology, Wilmer Institute, Johns Hopkins School of Medicine, Baltimore, MD, USA.
| |
Collapse
|
47
|
Abstract
The rebound tonometer has a unique mechanism for measuring intraocular pressure (IOP) and has become popular worldwide due to its ease of use. The most notable advantages are the lack of an air-puff and need for topical anesthesia, ease of operation and transport, and the ability to use it with children. Four rebound tonometers (Icare® TA01i, Icare PRO, Icare HOME, and Icare ic100) are currently available for clinical examination. It is important to understand the characteristics of each tonometer and select the most appropriate one because the IOP values and the purpose of measurement are different. In this review, with the goal of improving the understanding of a range of tonometers, the issues with each device are discussed.
Collapse
Affiliation(s)
- Shunsuke Nakakura
- Department of Ophthalmology, Saneikai Tsukazaki Hospital, Himeji City, Japan,
| |
Collapse
|
48
|
Abstract
PURPOSE OF REVIEW IOP is the only treatable risk factor contributing to glaucoma and most management and treatment of glaucoma is based on IOP. However, current IOP measurements are limited to office hours and control of glaucoma in many patients would benefit from the ability to monitor IOP diurnally so as not to miss abnormal pressures, which occur outside of office hours Consequently, to improve patient care, the ability to enable accurate and minimally disruptive diurnal IOP monitoring would improve caring for these patients. RECENT FINDINGS The studies we selected for this review can be divided into three categories: self-/home-tonometry, continuous invasive intraocular pressure measurements, and continuous noninvasive ocular measurements. SUMMARY The desire to obtain better insight in our patients' true diurnal IOP has led to the development of home-tonometers, in addition to extraocular and intraocular continuous pressure measurement devices. All of the devices have respective advantages and disadvantages, but none to date completely fulfills the goal of providing a true diurnal IOP profile.Video abstracthttp://links.lww.com/COOP/A27.
Collapse
|
49
|
Tonometers-which one should I use? Eye (Lond) 2018; 32:931-937. [PMID: 29456251 DOI: 10.1038/s41433-018-0040-4] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2017] [Revised: 01/22/2018] [Accepted: 01/25/2018] [Indexed: 11/08/2022] Open
Abstract
Although several factors are known to play a role in the development and progression of glaucoma, intraocular pressure (IOP) remains the only modifiable risk factor. Medical and surgical treatments for glaucoma both aim to reduce IOP to minimize disease progression. Tonometry is therefore an essential element of the ophthalmological exam. There are several types of tonometers available currently. These range from well-established instruments that have been in clinical use for decades to new devices, which are the result of recent technological advances. The various instruments have advantages and disadvantages that affect their suitability for a given setting, purpose, and patient population. In this review, we aim to describe the most commonly available tonometers today along with their advantages, disadvantages, and applicability.
Collapse
|
50
|
Huang J, Katalinic P, Kalloniatis M, Hennessy MP, Zangerl B. Diurnal Intraocular Pressure Fluctuations with Self-tonometry in Glaucoma Patients and Suspects: A Clinical Trial. Optom Vis Sci 2018; 95:88-95. [PMID: 29370022 PMCID: PMC5794241 DOI: 10.1097/opx.0000000000001172] [Citation(s) in RCA: 32] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2017] [Accepted: 12/01/2017] [Indexed: 11/25/2022] Open
Abstract
SIGNIFICANCE This article shows that self-tonometry can provide robust measures of diurnal intraocular pressure (IOP) and also detect changes to IOP in response to treatment within a short period of monitoring. These advances in IOP monitoring may contribute to improved management of glaucoma patients and suspects. PURPOSE The aim of this study was to prospectively investigate the utility of rebound self-tonometry performed over several weeks for detecting diurnal IOP fluctuations in glaucoma patients and suspects and also initial response to topical treatment in glaucoma patients. METHODS Forty patients were recruited following glaucoma-specific examination. Subsequent to successful training with the iCare HOME tonometer, patients were instructed to measure IOP, in a sitting position, four times a day over 4 to 6 weeks. Date, time, laterality, and IOP downloaded from the tonometer and clinical examination data, including applanation IOP and corneal thickness, were analyzed. A user satisfaction survey was also administered at study completion. t Test and analysis of variance were used to compare groups and IOP across days. Pearson correlation was used to compare measurements to Goldmann applanation tonometry and IOP measurements from the first day/s to the overall mean IOP. RESULTS Twenty-seven patients (18 suspects and 9 glaucoma patients) completed data collection. Patients self-measured IOP on 118 (±29) occasions for 40 (±7.4) days. Two dominant patterns of fluctuation were revealed: peak IOP upon awakening (n = 11) and at midday (n = 13). Diurnal IOP measured in the first 7 days showed strong correlation to diurnal IOP across the entire study period (r = 0.82, P < .0001). Within 24 hours of treatment commencement (latanoprost 0.005% ophthalmic solution), IOP reduced from 23.9 (±5.2) to 16.1 (±2.6) mmHg. Overall, patients rated the instrument as easy to use, although difficulties with correct alignment were expressed. CONCLUSIONS Rebound self-tonometry demonstrated utility for measuring diurnal IOP fluctuations in most patients, hence enhancing management of patient with or at risk of developing glaucoma.
Collapse
Affiliation(s)
- Jessie Huang
- Centre for Eye Health, University of New South Wales Sydney, Sydney, New South Wales, Australia
- School of Optometry and Vision Science, University of New South Wales Sydney, Sydney, New South Wales, Australia
| | - Paula Katalinic
- Centre for Eye Health, University of New South Wales Sydney, Sydney, New South Wales, Australia
- School of Optometry and Vision Science, University of New South Wales Sydney, Sydney, New South Wales, Australia
| | - Michael Kalloniatis
- Centre for Eye Health, University of New South Wales Sydney, Sydney, New South Wales, Australia
- School of Optometry and Vision Science, University of New South Wales Sydney, Sydney, New South Wales, Australia
| | - Michael P Hennessy
- Centre for Eye Health, University of New South Wales Sydney, Sydney, New South Wales, Australia
- Department of Ophthalmology, Prince of Wales Hospital, Sydney, New South Wales, Australia *
| | - Barbara Zangerl
- Centre for Eye Health, University of New South Wales Sydney, Sydney, New South Wales, Australia
| |
Collapse
|