1
|
Sistemich L, Ebbinghaus S. Heat application in live cell imaging. FEBS Open Bio 2024. [PMID: 39489617 DOI: 10.1002/2211-5463.13912] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2024] [Revised: 08/29/2024] [Accepted: 10/01/2024] [Indexed: 11/05/2024] Open
Abstract
Thermal heating of biological samples allows to reversibly manipulate cellular processes with high temporal and spatial resolution. Manifold heating techniques in combination with live-cell imaging were developed, commonly tailored to customized applications. They include Peltier elements and microfluidics for homogenous sample heating as well as infrared lasers and radiation absorption by nanostructures for spot heating. A prerequisite of all techniques is that the induced temperature changes are measured precisely which can be the main challenge considering subcellular structures or multicellular organisms as target regions. This article discusses heating and temperature sensing techniques for live-cell imaging, leading to future applications in cell biology.
Collapse
Affiliation(s)
- Linda Sistemich
- Chair of Biophysical Chemistry, Ruhr-University Bochum, Germany
- Research Center Chemical Sciences and Sustainability, Research Alliance Ruhr, Bochum, Germany
| | - Simon Ebbinghaus
- Chair of Biophysical Chemistry, Ruhr-University Bochum, Germany
- Research Center Chemical Sciences and Sustainability, Research Alliance Ruhr, Bochum, Germany
| |
Collapse
|
2
|
Wilcox S, Huang Z, Shah J, Yang X, Chen Y. Respiration-Induced Organ Motion Compensation: A Review. Ann Biomed Eng 2024:10.1007/s10439-024-03630-w. [PMID: 39384667 DOI: 10.1007/s10439-024-03630-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2024] [Accepted: 09/23/2024] [Indexed: 10/11/2024]
Abstract
PURPOSE Motion of organs in the abdominal and thoracic cavity caused by respiration is a major issue that affects a wide range of clinical diagnoses or treatment outcomes, including radiotherapy, high-intensity focused ultrasound ablation, and many generalized percutaneous needle interventions. These motions pose significant challenges in accurately reaching the target even for the experienced clinician. METHODS This review was conducted through comprehensive search on IEEE Explore, Google Scholar, and PubMed. RESULTS Diverse methods have been proposed to compensate for this motion effect to enable effective surgical operations. This review paper aims to examine the current respiratory motion compensation techniques used across the clinical procedures of radiotherapy, high-intensity focused ultrasound, and percutaneous needle procedures. CONCLUSION The complexity of respiratory-induced organ motion and diversity of areas for which compensation can be applied allows for a variety of methods to be implemented. This review aims to serve as inspiration for the future development of new systems to achieve clinical relevance.
Collapse
Affiliation(s)
- Samuel Wilcox
- Institute of Robotics and Intelligent Machines, Georgia Institute of Technology, 801 Atlantic Dr NW, Atlanta, GA, 30332, USA
| | - Zhefeng Huang
- Institute of Robotics and Intelligent Machines, Georgia Institute of Technology, 801 Atlantic Dr NW, Atlanta, GA, 30332, USA
| | - Jay Shah
- Department of Radiology, Emory University, 1364 Clifton Rd, Atlanta, GA, 30329, USA
| | - Xiaofeng Yang
- Department of Radiation Oncology, Emory University, 1364 Clifton Rd, Atlanta, GA, 30329, USA
| | - Yue Chen
- Institute of Robotics and Intelligent Machines, Georgia Institute of Technology, 801 Atlantic Dr NW, Atlanta, GA, 30332, USA.
- Department of Biomedical Engineering, Georgia Institute of Technology/Emory University, 313 Ferst Dr STE 2127, Atlanta, GA, 30332, USA.
| |
Collapse
|
3
|
Lari S, Kohandel M, Kwon HJ. Model based deep learning method for focused ultrasound pathway scanning. Sci Rep 2024; 14:20042. [PMID: 39198623 PMCID: PMC11358149 DOI: 10.1038/s41598-024-70689-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2024] [Accepted: 08/20/2024] [Indexed: 09/01/2024] Open
Abstract
The primary purpose of high-intensity focused ultrasound (HIFU), a non-invasive medical therapy, is to precisely target and ablate tumors by focusing high-frequency ultrasound from an external power source. A series of ablations must be performed in order to treat a big volume of tumors, as a single ablation can only remove a small amount of tissue. To maximize therapeutic efficacy while minimizing adverse side effects such as skin burns, preoperative treatment planning is essential in determining the focal site and sonication duration for each ablation. Here, we introduce a machine learning-based approach for designing HIFU treatment plans, which makes use of a map of the material characteristics unique to a patient alongside an accurate thermal simulation. A numerical model was employed to solve the governing equations of HIFU process and to simulate the HIFU absorption mechanism, including ensuing heat transfer process and the temperature rise during the sonication period. To validate the accuracy of this numerical model, a series of tests was conducted using ex vivo bovine liver. The findings indicate that the developed models properly represent the considerable variances observed in tumor geometrical shapes and proficiently generate well-defined closed treated regions based on imaging data. The proposed strategy facilitated the formulation of high-quality treatment plans, with an average tissue over- or under-treatment rate of less than 0.06%. The efficacy of the numerical model in accurately predicting the heating process of HIFU, when combined with machine learning techniques, was validated through quantitative comparison with experimental data. The proposed approach in cooperation with HIFU simulation holds the potential to enhance presurgical HIFU plan.
Collapse
Affiliation(s)
- Salman Lari
- Department of Mechanical and Mechatronics Engineering, University of Waterloo, Waterloo, ON, N2L 3G1, Canada
| | - Mohammad Kohandel
- Department of Applied Mathematics, University of Waterloo, Waterloo, ON, N2L 3G1, Canada
| | - Hyock Ju Kwon
- Department of Mechanical and Mechatronics Engineering, University of Waterloo, Waterloo, ON, N2L 3G1, Canada.
| |
Collapse
|
4
|
Samaddar A, Singh R, Yang X, Ebersole KC, Forrest ML. Investigating the potential of catheter-assisted pulsed focused ultrasound ablation for atherosclerotic plaques. Med Phys 2024; 51:5181-5189. [PMID: 38873842 PMCID: PMC11409400 DOI: 10.1002/mp.17253] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2023] [Revised: 05/17/2024] [Accepted: 05/18/2024] [Indexed: 06/15/2024] Open
Abstract
BACKGROUND Atherosclerosis is a condition in which an adhesive substance called plaque accumulates over time inside the arteries. Plaque buildup results in the constriction of arteries, causing a shortage of blood supply to tissues and organs. Removing atherosclerotic plaques controls the development of acute ischemic stroke and heart diseases. It remains imperative for positive patient outcomes. PURPOSE This study sought to develop a minimally invasive technique for removing arterial plaques by applying focused ultrasound (FUS) energy on the metal surface of a nitinol catheter wire to induce inertial cavitation. The induced cavitation can deplete plaque mechanically inside the arteries, leading towards improved recanalization of blood vessels. METHODS The enhanced cavitation effect induced by combining FUS with a metal catheter was first verified by exposing agar phantom gels with or without a 0.9-mm diameter nitinol wire to an acoustic field produced by a 0.5-MHz FUS transducer. The phenomenon was further confirmed in pork belly fat samples with or without a 3-mm diameter nitinol catheter wire. Cavitation was monitored by detecting the peaks of emitted ultrasound signals from the samples using a passive cavitation detector (PCD). Cavitation threshold values were determined by observing the jump in the peak amplitude of signals received by the PCD when the applied FUS peak negative pressure (PNP) increased. To simulate arterial plaque removal, FUS with or without a catheter was used to remove tissues from pork belly fat samples and the lipid cores of human atherosclerotic plaque samples using 2500-cycle FUS bursts at 10% duty cycle and a burst repetition rate of 20 Hz. Treatment outcomes were quantified by subtracting the weight of samples before treatment from the weight of samples after treatment. All measurements were repeated 5 times (n = 5) unless otherwise indicated, and paired t-tests were used to compare the means of two groups. A p-value of <0.05 will be considered significant. RESULTS Our results showed that with a nitinol wire, the cavitation threshold in agar phantoms was reduced to 2.6 MPa from 4.3 MPa PNP when there was no nitinol wire in the focal region of FUS. For pork belly fat samples, cavitation threshold values were 1.0 and 2.0 MPa PNP, with and without a catheter wire, respectively. Pork belly fat tissues and lipid cores of atherosclerotic plaques were depleted at the interface between a catheter and the samples at 2 and 4 MPa FUS PNP, respectively. The results showed that with a catheter wire in the focal region of a 3-min FUS treatment session, 24.7 and 25.6 mg of lipid tissues were removed from pork belly fat and human atherosclerotic samples, respectively. In contrast, the FUS-only group showed no reduction in sample weight. The differences between FUS-only and FUS-plus-catheter groups were statistically significant (p < 0.001 for the treatment on pork belly samples, and p < 0.01 for the treatment on human atherosclerotic samples). CONCLUSION This study demonstrated the feasibility of catheter-assisted FUS therapy for removing atherosclerotic plaques.
Collapse
Affiliation(s)
- Abhirup Samaddar
- Institute for Bioengineering Research and Department of Mechanical Engineering, University of Kansas, Lawrence, Kansas, USA
| | - Rohit Singh
- Institute for Bioengineering Research and Department of Mechanical Engineering, University of Kansas, Lawrence, Kansas, USA
| | - Xinmai Yang
- Institute for Bioengineering Research and Department of Mechanical Engineering, University of Kansas, Lawrence, Kansas, USA
| | - Koji C Ebersole
- Department of Neurosurgery, the University of Kansas Medical Center, Kansas City, Kansas, USA
| | - M Laird Forrest
- Department of Pharmaceutical Chemistry, the University of Kansas, Lawrence, Kansas, USA
| |
Collapse
|
5
|
Fura Ł, Tymkiewicz R, Kujawska T. Numerical studies on shortening the duration of HIFU ablation therapy and their experimental validation. ULTRASONICS 2024; 142:107371. [PMID: 38852549 DOI: 10.1016/j.ultras.2024.107371] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/08/2023] [Revised: 05/09/2024] [Accepted: 06/03/2024] [Indexed: 06/11/2024]
Abstract
High Intensity Focused Ultrasound (HIFU) is used in clinical practice for thermal ablation of malignant and benign solid tumors located in various organs. One of the reason limiting the wider use of this technology is the long treatment time resulting from i.a. the large difference between the size of the focal volume of the heating beam and the size of the tumor. Therefore, the treatment of large tumors requires scanning their volume with a sequence of single heating beams, the focus of which is moved in the focal plane along a specific trajectory with specific time and distance interval between sonications. To avoid an undesirable increase in the temperature of healthy tissues surrounding the tumor during scanning, the acoustic power and exposure time of each HIFU beam as well as the time intervals between sonications should be selected in such a way as to cover the entire volume of the tumor with necrosis as quickly as possible. This would reduce the costs of treatment. The aim of this study was to quantitatively evaluate the hypothesis that selecting the average acoustic power and exposure time for each individual heating beam, as well as the temporal intervals between sonications, can significantly shorten treatment time. Using 3D numerical simulations, the dependence of the duration of treatment of a tumor with a diameter of 5 mm or 9 mm (requiring multiple exposure to the HIFU beam) on the sonication parameters (acoustic power, exposure time) of each single beam capable of delivering the threshold thermal dose (CEM43 = 240 min) to the treated tissue volume was examined. The treatment duration was determined as the sum of exposure times to individual beams and time intervals between sonications. The tumor was located inside the ex vivo tissue sample at a depth of 12.6 mm. The thickness of the water layer between the HIFU transducer and the tissue was 50 mm. The sonication and scanning parameters selected using the developed algorithm shortened the duration of the ablation procedure by almost 14 times for a 5-mm tumor and 20 times for a 9-mm tumor compared to the duration of the same ablation plan when a HIFU beam was used of a constant acoustic power, constant exposure time (3 s) and constant long time intervals (120 s) between sonications. Results of calculations of the location and size of the necrotic lesion formed were experimentally verified on ex vivo pork loin samples, showing good agreement between them. In this way, it was proven that the proper selection of sonication and scanning parameters for each HIFU beam allows to significantly shorten the time of HIFU therapy.
Collapse
Affiliation(s)
- Łukasz Fura
- Institute of Fundamental Technological Research, Polish Academy of Sciences, Pawińskiego 5B, 02-106 Warsaw, Poland.
| | - Ryszard Tymkiewicz
- Institute of Fundamental Technological Research, Polish Academy of Sciences, Pawińskiego 5B, 02-106 Warsaw, Poland
| | - Tamara Kujawska
- Institute of Fundamental Technological Research, Polish Academy of Sciences, Pawińskiego 5B, 02-106 Warsaw, Poland
| |
Collapse
|
6
|
Campbell WA, Makary MS. Advances in Image-Guided Ablation Therapies for Solid Tumors. Cancers (Basel) 2024; 16:2560. [PMID: 39061199 PMCID: PMC11274819 DOI: 10.3390/cancers16142560] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2024] [Revised: 06/26/2024] [Accepted: 07/10/2024] [Indexed: 07/28/2024] Open
Abstract
Image-guided solid tumor ablation methods have significantly advanced in their capability to target primary and metastatic tumors. These techniques involve noninvasive or percutaneous insertion of applicators to induce thermal, electrochemical, or mechanical stress on malignant tissue to cause tissue destruction and apoptosis of the tumor margins. Ablation offers substantially lower risks compared to traditional methods. Benefits include shorter recovery periods, reduced bleeding, and greater preservation of organ parenchyma compared to surgical intervention. Due to the reduced morbidity and mortality, image-guided tumor ablation offers new opportunities for treatment in cancer patients who are not candidates for resection. Currently, image-guided ablation techniques are utilized for treating primary and metastatic tumors in various organs with both curative and palliative intent, including the liver, pancreas, kidneys, thyroid, parathyroid, prostate, lung, breast, bone, and soft tissue. The invention of new equipment and techniques is expanding the criteria of eligible patients for therapy, as now larger and more high-risk tumors near critical structures can be ablated. This article provides an overview of the different imaging modalities, noninvasive, and percutaneous ablation techniques available and discusses their applications and associated complications across various organs.
Collapse
Affiliation(s)
- Warren A. Campbell
- Division of Vascular and Interventional Radiology, Department of Radiology, University of Virginia, Charlottesville, VA 22903, USA
| | - Mina S. Makary
- Division of Vascular and Interventional Radiology, Department of Radiology, The Ohio State University Wexner Medical Center, Columbus, OH 43210, USA
| |
Collapse
|
7
|
Yang Y, Wang Y, Zeng F, Chen Y, Chen Z, Yan F. Ultrasound-visible engineered bacteria for tumor chemo-immunotherapy. Cell Rep Med 2024; 5:101512. [PMID: 38640931 PMCID: PMC11148858 DOI: 10.1016/j.xcrm.2024.101512] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2023] [Revised: 01/04/2024] [Accepted: 03/20/2024] [Indexed: 04/21/2024]
Abstract
Our previous work developed acoustic response bacteria, which enable the precise tuning of transgene expression through ultrasound. However, it is still difficult to visualize these bacteria in order to guide the sound wave to precisely irradiate them. Here, we develop ultrasound-visible engineered bacteria and chemically modify them with doxorubicin (DOX) on their surfaces. These engineered bacteria (Ec@DIG-GVs) can produce gas vesicles (GVs), providing a real-time imaging guide for remote hyperthermia high-intensity focused ultrasound (hHIFU) to induce the expression of the interferon (IFN)-γ gene. The production of IFN-γ can kill tumor cells, induce macrophage polarization from the M2 to the M1 phenotype, and promote the maturation of dendritic cells. DOX can be released in the acidic tumor microenvironment, resulting in immunogenic cell death of tumor cells. The concurrent effects of IFN-γ and DOX activate a tumor-specific T cell response, producing the synergistic anti-tumor efficacy. Our study provides a promising strategy for bacteria-mediated tumor chemo-immunotherapy.
Collapse
Affiliation(s)
- Yaozhang Yang
- Key Laboratory of Medical Imaging Precision Theranostics and Radiation Protection, University of South China, College of Hunan Province, Changsha, Hunan 410028, China; Institution of Medical Imaging, Hengyang Medical School, University of South China, Hengyang, Hunan 421001, China; CAS Key Laboratory of Quantitative Engineering Biology, Shenzhen Institute of Synthetic Biology, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China
| | - Yuanyuan Wang
- CAS Key Laboratory of Quantitative Engineering Biology, Shenzhen Institute of Synthetic Biology, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China
| | - Fengyi Zeng
- Key Laboratory of Medical Imaging Precision Theranostics and Radiation Protection, University of South China, College of Hunan Province, Changsha, Hunan 410028, China; Institution of Medical Imaging, Hengyang Medical School, University of South China, Hengyang, Hunan 421001, China
| | - Yuhao Chen
- Faculty of Health Sciences, University of Macau, Taipa, Macau SAR, China
| | - Zhiyi Chen
- Key Laboratory of Medical Imaging Precision Theranostics and Radiation Protection, University of South China, College of Hunan Province, Changsha, Hunan 410028, China; Institution of Medical Imaging, Hengyang Medical School, University of South China, Hengyang, Hunan 421001, China; The Affiliated Changsha Central Hospital, Hengyang Medical School, University of South China, Changsha, Hunan 410028, China.
| | - Fei Yan
- CAS Key Laboratory of Quantitative Engineering Biology, Shenzhen Institute of Synthetic Biology, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China.
| |
Collapse
|
8
|
Lesser T, Wolfram F, Braun C, Gottschall R. Effects of unilateral superimposed high-frequency jet ventilation on porcine hemodynamics and gas exchange during one-lung flooding. World J Exp Med 2024; 14:87256. [PMID: 38590298 PMCID: PMC10999063 DOI: 10.5493/wjem.v14.i1.87256] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/13/2023] [Revised: 11/30/2023] [Accepted: 12/29/2023] [Indexed: 03/19/2024] Open
Abstract
BACKGROUND Superimposed high-frequency jet ventilation (SHFJV) is suitable for respiratory motion reduction and essential for effective lung tumor ablation. Fluid filling of the target lung wing one-lung flooding (OLF) is necessary for therapeutic ultrasound applications. However, whether unilateral SHFJV allows adequate hemodynamics and gas exchange is unclear. AIM To compared SHFJV with pressure-controlled ventilation (PCV) during OLF by assessing hemodynamics and gas exchange in different animal positions. METHODS SHFJV or PCV was used alternatingly to ventilate the non-flooded lungs of the 12 anesthetized pigs during OLF. The animal positions were changed from left lateral position to supine position (SP) to right lateral position (RLP) every 30 min. In each position, ventilation was maintained for 15 min in both modalities. Hemodynamic variables and arterial blood gas levels were repeatedly measured. RESULTS Unilateral SHFJV led to lower carbon dioxide removal than PCV without abnormally elevated carbon dioxide levels. SHFJV slightly decreased oxygenation in SP and RLP compared with PCV; the lowest values of PaO2 and PaO2/FiO2 ratio were found in SP [13.0; interquartile range (IQR): 12.6-5.6 and 32.5 (IQR: 31.5-38.9) kPa]. Conversely, during SHFJV, the shunt fraction was higher in all animal positions (highest in the RLP: 0.30). CONCLUSION In porcine model, unilateral SHFJV may provide adequate ventilation in different animal positions during OLF. Lower oxygenation and CO2 removal rates compared to PCV did not lead to hypoxia or hypercapnia. SHFJV can be safely used for lung tumor ablation to minimize ventilation-induced lung motion.
Collapse
Affiliation(s)
- Thomas Lesser
- Department of Thoracic and Vascular Surgery, SRH Wald Klinikum Gera, Gera D-07548, Germany
| | - Frank Wolfram
- Department of Thoracic and Vascular Surgery, SRH Wald Klinikum Gera, Gera D-07548, Germany
| | - Conny Braun
- Central Experimental Animal Facility, Jena University Hospital, Jena 07743, Germany
| | - Reiner Gottschall
- Department of Anaesthesiology and Intensive Care, Jena University Hospital, Jena 07747, Germany
| |
Collapse
|
9
|
Rosnitskiy PB, Khokhlova TD, Schade GR, Sapozhnikov OA, Khokhlova VA. Treatment Planning and Aberration Correction Algorithm for HIFU Ablation of Renal Tumors. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2024; 71:341-353. [PMID: 38231825 PMCID: PMC11003458 DOI: 10.1109/tuffc.2024.3355390] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/19/2024]
Abstract
High-intensity focused ultrasound (HIFU) applications for thermal or mechanical ablation of renal tumors often encounter challenges due to significant beam aberration and refraction caused by oblique beam incidence, inhomogeneous tissue layers, and presence of gas and bones within the beam. These losses can be significantly mitigated through sonication geometry planning, patient positioning, and aberration correction using multielement phased arrays. Here, a sonication planning algorithm is introduced, which uses the simulations to select the optimal transducer position and evaluate the effect of aberrations and acoustic field quality at the target region after aberration correction. Optimization of transducer positioning is implemented using a graphical user interface (GUI) to visualize a segmented 3-D computed tomography (CT)-based acoustic model of the body and to select sonication geometry through a combination of manual and automated approaches. An HIFU array (1.5 MHz, 256 elements) and three renal cell carcinoma (RCC) cases with different tumor locations and patient body habitus were considered. After array positioning, the correction of aberrations was performed using a combination of backpropagation from the focus with an ordinary least squares (OLS) optimization of phases at the array elements. The forward propagation was simulated using a combination of the Rayleigh integral and k-space pseudospectral method (k-Wave toolbox). After correction, simulated HIFU fields showed tight focusing and up to threefold higher maximum pressure within the target region. The addition of OLS optimization to the aberration correction method yielded up to 30% higher maximum pressure compared to the conventional backpropagation and up to 250% higher maximum pressure compared to the ray-tracing method, particularly in strongly distorted cases.
Collapse
|
10
|
Shams A, Bidi S, Gavaises M. Investigation of the ultrasound-induced collapse of air bubbles near soft materials. ULTRASONICS SONOCHEMISTRY 2024; 102:106723. [PMID: 38101107 PMCID: PMC10764290 DOI: 10.1016/j.ultsonch.2023.106723] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/25/2023] [Revised: 11/28/2023] [Accepted: 12/08/2023] [Indexed: 12/17/2023]
Abstract
A numerical investigation into the ultrasound-induced collapse of air bubbles near soft materials, utilizing a novel multi-material diffuse interface method (DIM) model with block-structured adaptive mesh refinement is presented. The present work expands from a previous five-equation DIM by incorporating Eulerian hyperelasticity. The model is applicable to any arbitrary number of interacting fluid and solid material. A single conservation law for the elastic stretch tensor enables tracking the deformations for all the solid materials. A series of benchmark cases are conducted, and the solution is found to be in excellent agreement against theoretical data. Subsequently, the ultrasound-induced bubble-tissue flow interactions are examined. The bubble radius was found to play a crucial role in dictating the stresses experienced by the tissue, underscoring its significance in medical applications. The results reveal that soft tissues primarily experience tensile forces during these interactions, suggesting potential tensile-driven injuries that may occur in relevant treatments. Moreover, regions of maximal tensile forces align with tissue elongation areas. It is documented that while early bubble dynamics remain relatively unaffected by changes in shear modulus, at later stages of the penetration processes and the deformation shapes, exhibit notable variations. Lastly, it is demonstrated that decreasing standoff distances enhances the interaction between bubbles and tissue, thereby increasing the stress levels in the tissue, although the behavior of the bubble dynamics remains largely unchanged.
Collapse
Affiliation(s)
- Armand Shams
- School of Science and Technology, City, University of London, UK.
| | - Saeed Bidi
- School of Science and Technology, City, University of London, UK; Institut Jean le Rond d'Alembert, Sorbonne Université and CNRS UMR 7190, F-75005 Paris, France
| | - Manolis Gavaises
- School of Science and Technology, City, University of London, UK
| |
Collapse
|
11
|
Falk KL, Laeseke PF, Kisting MA, Zlevor AM, Knott EA, Smolock AR, Bradley C, Vlaisavljevich E, Lee FT, Ziemlewicz TJ. Clinical translation of abdominal histotripsy: a review of preclinical studies in large animal models. Int J Hyperthermia 2023; 40:2272065. [PMID: 37875279 PMCID: PMC10629829 DOI: 10.1080/02656736.2023.2272065] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2023] [Accepted: 10/12/2023] [Indexed: 10/26/2023] Open
Abstract
Histotripsy is an emerging noninvasive, non-thermal, and non-ionizing focused ultrasound (US) therapy that can be used to destroy targeted tissue. Histotripsy has evolved from early laboratory prototypes to clinical systems which have been comprehensively evaluated in the preclinical environment to ensure safe translation to human use. This review summarizes the observations and results from preclinical histotripsy studies in the liver, kidney, and pancreas. Key findings from these studies include the ability to make a clinically relevant treatment zone in each organ with maintained collagenous architecture, potentially allowing treatments in areas not currently amenable to thermal ablation. Treatments across organ capsules have proven safe, including in anticoagulated models which may expand patients eligible for treatment or eliminate the risk associated with taking patients off anti-coagulation. Treatment zones are well-defined with imaging and rapidly resorb, which may allow improved evaluation of treatment zones for residual or recurrent tumor. Understanding the effects of histotripsy in animal models will help inform physicians adopting histotripsy for human clinical use.
Collapse
Affiliation(s)
- Katrina L Falk
- Department of Biomedical Engineering, University of Wisconsin, Madison, Wisconsin, USA
- Department of Radiology, University of Wisconsin, Madison, Wisconsin, USA
| | - Paul F Laeseke
- Department of Biomedical Engineering, University of Wisconsin, Madison, Wisconsin, USA
- Department of Radiology, University of Wisconsin, Madison, Wisconsin, USA
| | - Meridith A Kisting
- Department of Radiology, University of Wisconsin, Madison, Wisconsin, USA
| | - Annie M Zlevor
- Department of Radiology, University of Wisconsin, Madison, Wisconsin, USA
| | - Emily A Knott
- Cleveland Clinic Lerner College of Medicine, Cleveland, Ohio, USA
| | - Amanda R Smolock
- Department of Radiology, Division of Interventional Radiology, Medical College of Wisconsin, Milwaukee, Wisconsin, USA
| | - Charles Bradley
- School of Veterinary Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Eli Vlaisavljevich
- Department of Biomedical Engineering and Mechanics, Virginia Polytechnic Institute and State University, Blacksburg, Virginia, USA
| | - Fred T Lee
- Department of Biomedical Engineering, University of Wisconsin, Madison, Wisconsin, USA
- Department of Radiology, University of Wisconsin, Madison, Wisconsin, USA
- Department of Urology, University of Wisconsin, Madison, Wisconsin, USA
| | | |
Collapse
|
12
|
Sadeghi-Goughari M, Rajabzadeh H, Han JW, Kwon HJ. Artificial intelligence-assisted ultrasound-guided focused ultrasound therapy: a feasibility study. Int J Hyperthermia 2023; 40:2260127. [PMID: 37748776 DOI: 10.1080/02656736.2023.2260127] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2023] [Accepted: 09/12/2023] [Indexed: 09/27/2023] Open
Abstract
OBJECTIVES Focused ultrasound (FUS) therapy has emerged as a promising noninvasive solution for tumor ablation. Accurate monitoring and guidance of ultrasound energy is crucial for effective FUS treatment. Although ultrasound (US) imaging is a well-suited modality for FUS monitoring, US-guided FUS (USgFUS) faces challenges in achieving precise monitoring, leading to unpredictable ablation shapes and a lack of quantitative monitoring. The demand for precise FUS monitoring heightens when complete tumor ablation involves controlling multiple sonication procedures. METHODS To address these challenges, we propose an artificial intelligence (AI)-assisted USgFUS framework, incorporating an AI segmentation model with B-mode ultrasound imaging. This method labels the ablated regions distinguished by the hyperechogenicity effect, potentially bolstering FUS guidance. We evaluated our proposed method using the Swin-Unet AI architecture, conducting experiments with a USgFUS setup on chicken breast tissue. RESULTS Our results showed a 93% accuracy in identifying ablated areas marked by the hyperechogenicity effect in B-mode imaging. CONCLUSION Our findings suggest that AI-assisted ultrasound monitoring can significantly improve the precision and control of FUS treatments, suggesting a crucial advancement toward the development of more effective FUS treatment strategies.
Collapse
Affiliation(s)
- Moslem Sadeghi-Goughari
- Department of Mechanical and Mechatronics Engineering, University of Waterloo, Waterloo, Ontario, Canada
| | - Hossein Rajabzadeh
- Department of Mechanical and Mechatronics Engineering, University of Waterloo, Waterloo, Ontario, Canada
| | - Jeong-Woo Han
- Department of Mechanical and Mechatronics Engineering, University of Waterloo, Waterloo, Ontario, Canada
| | - Hyock-Ju Kwon
- Department of Mechanical and Mechatronics Engineering, University of Waterloo, Waterloo, Ontario, Canada
| |
Collapse
|
13
|
Wu X, Sanders JL, Dundar MM, Oralkan Ö. Deep-Learning-Based High-Intensity Focused Ultrasound Lesion Segmentation in Multi-Wavelength Photoacoustic Imaging. Bioengineering (Basel) 2023; 10:1060. [PMID: 37760164 PMCID: PMC10526078 DOI: 10.3390/bioengineering10091060] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2023] [Revised: 09/01/2023] [Accepted: 09/05/2023] [Indexed: 09/29/2023] Open
Abstract
Photoacoustic (PA) imaging can be used to monitor high-intensity focused ultrasound (HIFU) therapies because ablation changes the optical absorption spectrum of the tissue, and this change can be detected with PA imaging. Multi-wavelength photoacoustic (MWPA) imaging makes this change easier to detect by repeating PA imaging at multiple optical wavelengths and sampling the optical absorption spectrum more thoroughly. Real-time pixel-wise classification in MWPA imaging can assist clinicians in monitoring HIFU lesion formation and will be a crucial milestone towards full HIFU therapy automation based on artificial intelligence. In this paper, we present a deep-learning-based approach to segment HIFU lesions in MWPA images. Ex vivo bovine tissue is ablated with HIFU and imaged via MWPA imaging. The acquired MWPA images are then used to train and test a convolutional neural network (CNN) for lesion segmentation. Traditional machine learning algorithms are also trained and tested to compare with the CNN, and the results show that the performance of the CNN significantly exceeds traditional machine learning algorithms. Feature selection is conducted to reduce the number of wavelengths to facilitate real-time implementation while retaining good segmentation performance. This study demonstrates the feasibility and high performance of the deep-learning-based lesion segmentation method in MWPA imaging to monitor HIFU lesion formation and the potential to implement this method in real time.
Collapse
Affiliation(s)
- Xun Wu
- Department of Electrical and Computer Engineering, North Carolina State University, Raleigh, NC 27606, USA;
| | - Jean L. Sanders
- Department of Electrical and Computer Engineering, North Carolina State University, Raleigh, NC 27606, USA;
| | - M. Murat Dundar
- Computer and Information Science Department, Indiana University—Purdue University, Indianapolis, IN 46202, USA;
| | - Ömer Oralkan
- Department of Electrical and Computer Engineering, North Carolina State University, Raleigh, NC 27606, USA;
| |
Collapse
|
14
|
Feng L, Shi X, Zhou F, Chen Y, Zhou X. Technical note: Evaluation of the acoustic radiation force imaging for predicting HIFU focus with in vitro and ex vivo experiments. Med Phys 2023; 50:5449-5459. [PMID: 37345709 DOI: 10.1002/mp.16565] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2023] [Revised: 05/07/2023] [Accepted: 06/02/2023] [Indexed: 06/23/2023] Open
Abstract
BACKGROUND High-intensity focused ultrasound (HIFU) is currently used for the treatment of various diseases, but it still lacks a reliable technique in the preoperative stage to accurately place its "energy blade" onto diseased targets. Acoustic radiation force imaging (ARFI) was recently introduced to tackle this issue, but its applicability and limitations were not clear. PURPOSE The aim of this study was to evaluate the performance of ARFI method in prediction of HIFU focal location at the preoperative stage. METHODS A point spread function (PSF) localization method, which was borrowed from the ultrasound super resolution field, was used to validate the core autocorrelation-based motion estimation algorithm in the ARFI procedure. Accuracy of the ARFI method for estimating the HIFU focus were tested with in vitro and ex vivo experiments with a clinically equivalent HIFU system. Comparisons were made between the estimated focal locations and those of the damaged area after the testing objects were cut open. RESULTS Results showed that the PSF localization was able to serve as a validating method for motion detection only when the tissue displacement was large. With the ARFI method, location of the HIFU focus could be accurately predicted by a 2D motion map preoperatively, and the axial spatial errors were less than 0.5 mm. However, the derived 2D motion maps can only be valuable when the acoustic stimulation in ARFI were strong enough, which was probably due to the fact that the HIFU focal locations were at large depths and the ultrasound imaging signal had low signal to noise ratio. CONCLUSION The ARFI method was indeed an accurate technique for preoperatively predicting HIFU focus in vitro and ex vivo. If clinical applications were to be considered, particularly in deep tissues, efforts might need to be made to improve ability of the ultrasound motion estimation technique.
Collapse
Affiliation(s)
- Lian Feng
- State Key Laboratory of Ultrasound Engineering in Medicine, College of Biomedical Engineering, Chongqing Medical University, Chongqing, China
| | - Xinwang Shi
- State Key Laboratory of Ultrasound Engineering in Medicine, College of Biomedical Engineering, Chongqing Medical University, Chongqing, China
| | - Fang Zhou
- State Key Laboratory of Ultrasound Engineering in Medicine, College of Biomedical Engineering, Chongqing Medical University, Chongqing, China
| | - Yanhua Chen
- State Key Laboratory of Ultrasound Engineering in Medicine, College of Biomedical Engineering, Chongqing Medical University, Chongqing, China
| | - Xiaowei Zhou
- State Key Laboratory of Ultrasound Engineering in Medicine, College of Biomedical Engineering, Chongqing Medical University, Chongqing, China
| |
Collapse
|
15
|
Juang EK, De Koninck LH, Vuong KS, Gnanaskandan A, Hsiao CT, Averkiou MA. Controlled Hyperthermia With High-Intensity Focused Ultrasound and Ultrasound Contrast Agent Microbubbles in Porcine Liver. ULTRASOUND IN MEDICINE & BIOLOGY 2023; 49:1852-1860. [PMID: 37246049 PMCID: PMC10330369 DOI: 10.1016/j.ultrasmedbio.2023.04.015] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/30/2022] [Revised: 04/07/2023] [Accepted: 04/25/2023] [Indexed: 05/30/2023]
Abstract
OBJECTIVE The objective of this work was to study microbubble-enhanced temperature elevation with high-intensity focused ultrasound (HIFU) at different acoustic pressures and under image guidance. The microbubbles were administered with either local or vascular injections (that mimic systemic injections) in perfused and non-perfused ex vivo porcine liver under ultrasound image guidance. METHODS Porcine liver was insonified for 30 s with a single-element HIFU transducer (0.9 MHz, 0.413 ms, 82% duty cycle, focal pressures of 0.6-3.5 MPa). Contrast microbubbles were injected either locally or through the vasculature. A needle thermocouple at the focus measured temperature elevation. Diagnostic ultrasound (Philips iU22, C5-1 probe) guided placement of the thermocouple and delivery of microbubbles and monitored the procedure in real time. RESULTS At lower acoustic pressures (0.6 and 1.2 MPa) in non-perfused liver, inertial cavitation of the injected microbubbles led to greater temperatures at the focus compared with HIFU-only treatments. At higher pressures (2.4 and 3.5 MPa) native inertial cavitation in the tissue (without injecting microbubbles) resulted in temperature elevations similar to those after injecting microbubbles. The heated area was larger when using microbubbles at all pressures. In the presence of perfusion, only local injections provided a sufficiently high concentration of microbubbles necessary for significant temperature enhancement. CONCLUSION Local injections of microbubbles provide a higher concentration of microbubbles in a smaller area, avoiding acoustic shadowing, and can lead to higher temperature elevation at lower pressures and increase the size of the heated area at all pressures.
Collapse
Affiliation(s)
- Eric K Juang
- Department of Bioengineering, University of Washington, Seattle, WA, USA
| | - Lance H De Koninck
- Department of Bioengineering, University of Washington, Seattle, WA, USA
| | - Kaleb S Vuong
- Department of Bioengineering, University of Washington, Seattle, WA, USA
| | - Aswin Gnanaskandan
- Department of Mechanical and Materials Engineering, Worcester Polytechnic Institute, Worcester, MA, USA
| | | | | |
Collapse
|
16
|
Yeingst TJ, Arrizabalaga JH, Rawnaque FS, Stone LP, Yeware A, Helton AM, Dhawan A, Simon JC, Hayes DJ. Controlled Degradation of Polycaprolactone Polymers through Ultrasound Stimulation. ACS APPLIED MATERIALS & INTERFACES 2023; 15:34607-34616. [PMID: 37432796 PMCID: PMC10496768 DOI: 10.1021/acsami.3c06873] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/13/2023]
Abstract
This study describes the development of an ultrasound-responsive polymer system that provides on-demand degradation when exposed to high-intensity focused ultrasound (HIFU). Diels-Alder cycloadducts were used to crosslink polycaprolactone (PCL) polymers and underwent a retro Diels-Alder reaction when stimulated with HIFU. Two Diels-Alder polymer compositions were explored to evaluate the link between reverse reaction energy barriers and polymer degradation rates. PCL crosslinked with isosorbide was also used as a non-Diels-Alder-based control polymer. An increase of HIFU exposure time and amplitude correlated with an increase of PCL degradation for Diels-Alder-based polymers. Ultrasound imaging during HIFU allowed for real-time visualization of the on-demand degradation through cavitation-based mechanisms. The temperature surrounding the sample was monitored with a thermocouple during HIFU stimulation; a minimal increase in temperature was observed. PCL polymers were characterized using Fourier transform infrared (FTIR) spectroscopy, nuclear magnetic resonance (NMR), differential scanning calorimetry (DSC), optical profilometry, and mechanical testing. PCL degradation byproducts were identified by mass spectrometry, and their cytocompatibility was evaluated in vitro. Overall, this study demonstrated that HIFU is an effective image-guided, external stimulus to control the degradation of Diels-Alder-based PCL polymers on-demand.
Collapse
Affiliation(s)
- Tyus J Yeingst
- Department of Biomedical Engineering, The Pennsylvania State University, University Park, Pennsylvania 16802, United States
| | - Julien H Arrizabalaga
- Department of Biomedical Engineering, The Pennsylvania State University, University Park, Pennsylvania 16802, United States
| | - Ferdousi S Rawnaque
- Graduate Program in Acoustics, The Pennsylvania State University, University Park, Pennsylvania 16802, United States
| | - Lindsay P Stone
- Department of Biomedical Engineering, The Pennsylvania State University, University Park, Pennsylvania 16802, United States
| | - Amar Yeware
- Department of Biomedical Engineering, The Pennsylvania State University, University Park, Pennsylvania 16802, United States
| | - Angelica M Helton
- Department of Biomedical Engineering, The Pennsylvania State University, University Park, Pennsylvania 16802, United States
| | - Aman Dhawan
- Department of Orthopaedics and Rehabilitation, Penn State College of Medicine, Milton S. Hershey Medical Center, Hershey, Pennsylvania 17033, United States
| | - Julianna C Simon
- Department of Biomedical Engineering, The Pennsylvania State University, University Park, Pennsylvania 16802, United States
- Graduate Program in Acoustics, The Pennsylvania State University, University Park, Pennsylvania 16802, United States
| | - Daniel J Hayes
- Department of Biomedical Engineering, The Pennsylvania State University, University Park, Pennsylvania 16802, United States
- Materials Research Institute, Millennium Science Complex, The Pennsylvania State University, University Park, Pennsylvania 16802, United States
- The Huck Institute of Life Sciences, Millennium Science Complex, The Pennsylvania State University, University Park, Pennsylvania 16802, United States
| |
Collapse
|
17
|
Choi H. Power Amplifier Design for Ultrasound Applications. MICROMACHINES 2023; 14:1342. [PMID: 37512653 PMCID: PMC10383379 DOI: 10.3390/mi14071342] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/16/2023] [Revised: 06/19/2023] [Accepted: 06/26/2023] [Indexed: 07/30/2023]
Abstract
A design analysis of the power amplifiers developed for ultrasound applications was conducted because ultrasound applications require different types of power amplifiers, which are one of the most critical electronic components in ultrasound systems. To generate acoustic signals using transducers, which are among the most important mechanical devices in ultrasound systems, an appropriate output voltage, current, or power signal must be produced by a power amplifier. Therefore, an appropriate design analysis of the power amplifier must be conducted to obtain the optimal performance from a transducer. In addition, because of new ultrasound research trends, such as ultrasound systems with other imaging modalities and wireless ultrasound systems, the selection of an appropriate power amplifier could improve the performance of an ultrasound system with other imaging and therapy modalities. This paper describes the design parameters of a power amplifier, including the gain, bandwidth, harmonic distortion, and efficiency. Each power amplifier has specific applications and limitations. Therefore, this review will assist design engineers and ultrasound researchers who need to develop or use power amplifiers in ultrasound applications.
Collapse
Affiliation(s)
- Hojong Choi
- Department of Electronic Engineering, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam 13120, Republic of Korea
| |
Collapse
|
18
|
He Y, Yang J, Hu F, Liao M, Nie Y, Zhu X, Zhang T, Song K, Li Q, Li X, Mei C, Wu Z, Lu Q, Zhong Z. A new method for preparing a rat intracerebral hemorrhage model by combining focused ultrasound and microbubbles. Animal Model Exp Med 2023; 6:103-110. [PMID: 36647712 PMCID: PMC10158945 DOI: 10.1002/ame2.12303] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2022] [Accepted: 12/02/2022] [Indexed: 01/18/2023] Open
Abstract
BACKGROUND We aimed to prepare a non-invasive, reproducible, and controllable rat model of intracerebral hemorrhage with focused ultrasound (FUS). METHODS A rat intracerebral hemorrhage (ICH) model was established by combining FUS and microbubbles (μBs), and edaravone was used to verify whether the free radical scavenger had a protective effect on the model. The brain tissue of each group was sectioned to observe the gross histology, blood-brain barrier (BBB) permeability, cerebral infarction volume, and histopathological changes. RESULTS Compared with the FUS group, the BBB permeability was significantly increased in the FUS + μBs (F&B) group (p = 0.0021). The second coronal slice in the F&B group had an obvious hemorrhage lesion, and the FUS + μBs + edaravone (F&B&E) group had smaller hemorrhage areas; however, ICH did not occur in the FUS group. The cerebral infarction volume in the F&B group was significantly larger than that in the FUS group (p = 0.0030) and F&B&E group (p = 0.0208). HE staining results showed that nerve fibrinolysis, neuronal necrosis, microglia production, and erythrocytes were found in both the F&B group and the F&B&E group, but the areas of the nerve fibrinolysis and neuronal necrosis in the F&B group were larger than the F&B&E group. CONCLUSIONS A rat ICH model was successfully prepared using the μBs assisted FUS treatment, and edaravone had a therapeutic effect on this model. This model can be used to study the pathophysiological mechanism of ICH-related diseases and in preclinical research on related new drugs.
Collapse
Affiliation(s)
- Yao He
- Laboratory of Nonhuman Primate Disease Modeling Research, State Key Laboratory of Biotherapy, West China Hospital, Sichuan University, Chengdu, China
| | - Jie Yang
- Department of Medical Ultrasound, West China Hospital, Sichuan University, Chengdu, China
| | - Fengying Hu
- School of Life Science and Technology, University of Electronic Science and Technology of China, Chengdu, China
| | - Min Liao
- Department of Medical Ultrasound, West China Hospital, Sichuan University, Chengdu, China
| | - Yuru Nie
- School of Life Science and Technology, University of Electronic Science and Technology of China, Chengdu, China
| | - Xiaoxia Zhu
- Department of Medical Ultrasound, West China Hospital, Sichuan University, Chengdu, China
| | - Tao Zhang
- School of Bioscience and Technology, Chengdu Medical College, Chengdu, China
| | - Keer Song
- Franklin College of Arts and Science, University of Georgia, Athens, Georgia, USA
| | - Qinxi Li
- Laboratory of Nonhuman Primate Disease Modeling Research, State Key Laboratory of Biotherapy, West China Hospital, Sichuan University, Chengdu, China
| | - Xiaojie Li
- Laboratory of Nonhuman Primate Disease Modeling Research, State Key Laboratory of Biotherapy, West China Hospital, Sichuan University, Chengdu, China
| | - Chenghan Mei
- Laboratory of Nonhuman Primate Disease Modeling Research, State Key Laboratory of Biotherapy, West China Hospital, Sichuan University, Chengdu, China
| | - Zhe Wu
- School of Life Science and Technology, University of Electronic Science and Technology of China, Chengdu, China
| | - Qiang Lu
- Department of Medical Ultrasound, West China Hospital, Sichuan University, Chengdu, China
| | - Zhihui Zhong
- Laboratory of Nonhuman Primate Disease Modeling Research, State Key Laboratory of Biotherapy, West China Hospital, Sichuan University, Chengdu, China
| |
Collapse
|
19
|
Richards LA, Stride E, Cleveland RO. Foam gratings as an alternative to customized acoustic lenses. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2023; 153:17. [PMID: 36732254 DOI: 10.1121/10.0016755] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/18/2023]
Abstract
This article describes a method of manipulating acoustic fields using transmission through foam gratings. The approach is investigated with an analytical model, a numerical model simulating full wave ultrasound propagation through the gratings, and experimental measurements. A grating is demonstrated that mimics a conventional ultrasound lens, modulating the phase of transmitted ultrasound while maximizing the transmitted amplitude. The performance of a foam grating is compared to a lens made of polydimethylsiloxane or three-dimensional printed resin. Using two gratings, independent control of amplitude and phase is demonstrated, with increased insertion loss. The primary advantages of this technique over conventional lenses are very rapid manufacture (<30 min), high repeatability due to the simplicity of manufacture, and the ability to control the amplitude of the transmitted ultrasound. Potential applications include generation of complex ultrasound fields for patient specific treatments in ultrasound therapy.
Collapse
Affiliation(s)
- Luke A Richards
- Institute of Biomedical Engineering, Department of Engineering Science, University of Oxford, Oxford OX3 7DQ, United Kingdom
| | - Eleanor Stride
- Institute of Biomedical Engineering, Department of Engineering Science, University of Oxford, Oxford OX3 7DQ, United Kingdom
| | - Robin O Cleveland
- Institute of Biomedical Engineering, Department of Engineering Science, University of Oxford, Oxford OX3 7DQ, United Kingdom
| |
Collapse
|
20
|
Zhao Y, Qin D, Chen J, Hou J, Ilovitsh T, Wan M, Wu L, Feng Y. On-demand regulation and enhancement of the nucleation in acoustic droplet vaporization using dual-frequency focused ultrasound. ULTRASONICS SONOCHEMISTRY 2022; 90:106224. [PMID: 36368292 PMCID: PMC9649937 DOI: 10.1016/j.ultsonch.2022.106224] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/26/2022] [Revised: 10/29/2022] [Accepted: 11/03/2022] [Indexed: 06/16/2023]
Abstract
Acoustic droplet vaporization (ADV) plays an important role in focused ultrasound theranostics. Better understanding of the relationship between the ultrasound parameters and the ADV nucleation could provide an on-demand regulation and enhancement of ADV for improved treatment outcome. In this work, ADV nucleation was performed in a dual-frequency focused ultrasound configuration that consisted of a continuous low-frequency ultrasound and a short high-frequency pulse. The combination was modelled to investigate the effects of the driving frequency and acoustic power on the nucleation rate, efficiency, onset time, and dimensions of the nucleation region. The results showed that the inclusion of short pulsed high-frequency ultrasound significantly increased the nucleation rate with less energy, reduced the nucleation onset time, and changed the length-width ratio of the nucleation region, indicating the dual-frequency ultrasound mode yields an efficient enhancement of the ADV nucleation, compared to a single-frequency ultrasound mode. Furthermore, the acoustic and temperature fields varied independently with the dual-frequency ultrasound parameters. This facilitated the spatial and temporal control over the ADV nucleation, and opens the door to the possibility to realize on-demand regulation of the ADV occurrence in ultrasound theranostics. In addition, the improved energy efficacy that is obtained with the dual-frequency configuration lowered the requirements on hardware system, increasing its flexibility and could facilitate its implementation in practical applications.
Collapse
Affiliation(s)
- Yubo Zhao
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, People's Republic of China
| | - Dui Qin
- School of Bioinformatics, Chongqing University of Posts and Telecommunications, Chongqing, People's Republic of China
| | - Junjie Chen
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, People's Republic of China
| | - Jin Hou
- Department of Otorhinolaryngology Head & Neck Surgery, Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an, People's Republic of China
| | - Tali Ilovitsh
- Department of Biomedical Engineering, Tel Aviv University, Tel Aviv 6997801, Israel
| | - Mingxi Wan
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, People's Republic of China
| | - Liang Wu
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, People's Republic of China.
| | - Yi Feng
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, People's Republic of China.
| |
Collapse
|
21
|
Chen X, Ma Y, Zhang J, Yang W, Jin C, Ran L, Zhu H, Bai J, Zhou K. Evaluating the long-term survival benefits of high intensity focused ultrasound ablation for hepatocellular carcinoma with portal vein tumor thrombus: a single center retrospective study. Int J Hyperthermia 2022; 39:1245-1253. [PMID: 36137611 DOI: 10.1080/02656736.2022.2122595] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/14/2022] Open
Abstract
AIMS To evaluate the long-term survival benefits of high intensity focused ultrasound (HIFU) ablation in patients with hepatocellular carcinoma (HCC) combined with portal vein tumor thrombus (PVTT). METHODS The data of patients with HCC-PVTT treated with HIFU from January 2014 to December 2019 were retrospectively analyzed. All patients received HIFU ablation for both PVTT and liver tumor in one session. Perioperative adverse events (AEs) were recorded, and follow-up was performed postoperatively. The Kaplan-Meier method was used for survival analysis. RESULTS Median follow-up was 13.75 ± 1.31 months. A total of 144 patients (male/female: 122/22, age: 54.15 ± 11.84 years old) were included in the study. A total of 267 liver tumors (tumor number: 1.87 ± 1.65, range 1-10) were treated with HIFU. The mean ± SD diameter of viable liver tumors was 100.98 ± 61.65 mm. The reported postoperative AEs of HIFU were skin edema (93.75%), local pain (69.44%) and fever (7.64%). There was no liver failure, gastrointestinal bleeding or perioperative death. The median overall survival (OS) time was 14 months, while the cumulative survival rates of 0.5, 1, 2 and 3 years were 79.0%, 58.6%, 33.3% and 5.9%, respectively. The median OS of PVTT types I, II and III was 22, 13 and 14 months, respectively, and the difference was not statistically significant (p > 0.05). CONCLUSION HIFU is a minimally invasive method for HCC-PVTT with fewer complications, which could prolong the OS. Patients with PVTT type III could benefit more from HIFU, compared to types I and II.
Collapse
Affiliation(s)
- Xing Chen
- State Key Laboratory of Ultrasound in Medicine and Engineering, College of Biomedical Engineering, Chongqing Medical University, Chongqing, China.,Chongqing Key Laboratory of Biomedical Engineering, Chongqing Medical University, Chongqing, China
| | - Yuhong Ma
- Clinical Center for Tumor Therapy, The Second Affiliated Hospital, Chongqing Medical University, Chongqing, China
| | - Jun Zhang
- Clinical Center for Tumor Therapy, The Second Affiliated Hospital, Chongqing Medical University, Chongqing, China
| | - Wei Yang
- Clinical Center for Tumor Therapy, The Second Affiliated Hospital, Chongqing Medical University, Chongqing, China
| | - Chengbing Jin
- Clinical Center for Tumor Therapy, The Second Affiliated Hospital, Chongqing Medical University, Chongqing, China
| | - Lifeng Ran
- Clinical Center for Tumor Therapy, The Second Affiliated Hospital, Chongqing Medical University, Chongqing, China
| | - Hui Zhu
- Clinical Center for Tumor Therapy, The Second Affiliated Hospital, Chongqing Medical University, Chongqing, China
| | - Jin Bai
- State Key Laboratory of Ultrasound in Medicine and Engineering, College of Biomedical Engineering, Chongqing Medical University, Chongqing, China.,Chongqing Key Laboratory of Biomedical Engineering, Chongqing Medical University, Chongqing, China
| | - Kun Zhou
- Clinical Center for Tumor Therapy, The Second Affiliated Hospital, Chongqing Medical University, Chongqing, China
| |
Collapse
|
22
|
Astolfi L, Hutchins DA, Watson RL, Thomas PJ, Ricci M, Nie L, Freear S, Cooper TP, Clare AT, Laureti S. Optimised polymer trapped-air lenses for ultrasound focusing in water exploiting Fabry-Pérot resonance. ULTRASONICS 2022; 125:106781. [PMID: 35671568 DOI: 10.1016/j.ultras.2022.106781] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/28/2021] [Revised: 05/10/2022] [Accepted: 05/31/2022] [Indexed: 06/15/2023]
Abstract
The concept of employing air volumes trapped inside polymer shells to make a lens for ultrasound focusing in water is investigated. The proposed lenses use evenly-spaced concentric rings, each having an air-filled polymer shell construction, defining concentric water-filled channels. Numerical simulations and experiments have shown that a plane wave can be focused, and that the amplification can be boosted by Fabry-Pérot resonances within the water channels with an appropriate choice of the lens thickness. The effect of the polymer shell thickness and the depth of the channels is discussed, as these factors can affect the geometry and hence the frequency of operation. The result was a lens with a Full Width at Half Maximum value of 0.65 of a wavelength at the focus. Results obtained on a metal-based counterpart are also shown for comparison. An advantage of this polymeric design is that it is easily constructed via additive manufacturing. This study shows that trapped-air lenses made of polymer are suitable for ultrasound focusing in water near 500 kHz.
Collapse
Affiliation(s)
- Lorenzo Astolfi
- School of Engineering, University of Warwick, Coventry CV4 7AL, UK
| | - David A Hutchins
- School of Engineering, University of Warwick, Coventry CV4 7AL, UK
| | - Richard L Watson
- Department of Mechanical Engineering Sciences, University of Surrey, Guildford, Surrey GU2 7XH, UK
| | - Peter J Thomas
- School of Engineering, University of Warwick, Coventry CV4 7AL, UK
| | - Marco Ricci
- Department of Informatics, Modelling, Electronics and System Engineering, University of Calabria, 87036 Rende, Italy
| | - Luzhen Nie
- School of Electronic and Electrical Engineering, University of Leeds, Leeds LS2 9JT, UK
| | - Steven Freear
- School of Electronic and Electrical Engineering, University of Leeds, Leeds LS2 9JT, UK
| | - Timothy P Cooper
- Department of Mechanical, Material and Manufacturing Engineering, University of Nottingham, University Park, Nottingham NG7 2RD, UK
| | - Adam T Clare
- Department of Mechanical, Material and Manufacturing Engineering, University of Nottingham, University Park, Nottingham NG7 2RD, UK
| | - Stefano Laureti
- Department of Informatics, Modelling, Electronics and System Engineering, University of Calabria, 87036 Rende, Italy.
| |
Collapse
|
23
|
Shi M, Bodian S, West SJ, Sathasivam S, Gordon RJ, Collier P, Vercauteren T, Desjardins AE, Noimark S, Xia W. Enhanced Photoacoustic Visualisation of Clinical Needles by Combining Interstitial and Extracorporeal Illumination of Elastomeric Nanocomposite Coatings. SENSORS (BASEL, SWITZERLAND) 2022; 22:6417. [PMID: 36080876 PMCID: PMC9460224 DOI: 10.3390/s22176417] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/19/2022] [Revised: 08/18/2022] [Accepted: 08/23/2022] [Indexed: 06/15/2023]
Abstract
Ultrasound (US) image guidance is widely used for minimally invasive procedures, but the invasive medical devices (such as metallic needles), especially their tips, can be poorly visualised in US images, leading to significant complications. Photoacoustic (PA) imaging is promising for visualising invasive devices and peripheral tissue targets. Light-emitting diodes (LEDs) acting as PA excitation sources facilitate the clinical translation of PA imaging, but the image quality is degraded due to the low pulse energy leading to insufficient contrast with needles at deep locations. In this paper, photoacoustic visualisation of clinical needles was enhanced by elastomeric nanocomposite coatings with superficial and interstitial illumination. Candle soot nanoparticle-polydimethylsiloxane (CSNP-PDMS) composites with high optical absorption and large thermal expansion coefficients were applied onto the needle exterior and the end-face of an optical fibre placed in the needle lumen. The excitation light was delivered at the surface by LED arrays and through the embedded optical fibre by a pulsed diode laser to improve the visibility of the needle tip. The performance was validated using an ex-vivo tissue model. An LED-based PA/US imaging system was used for imaging the needle out-of-plane and in-plane insertions over approach angles of 20 deg to 55 deg. The CSNP-PDMS composite conferred substantial visual enhancements on both the needle shaft and the tip, with an average of 1.7- and 1.6-fold improvements in signal-to-noise ratios (SNRs), respectively. With the extended light field involving extracorporeal and interstitial illumination and the highly absorbing coatings, enhanced visualisation of the needle shaft and needle tip was achieved with PA imaging, which could be helpful in current US-guided minimally invasive surgeries.
Collapse
Affiliation(s)
- Mengjie Shi
- School of Biomedical Engineering and Imaging Sciences, King’s College London, London SE1 7EH, UK
| | - Semyon Bodian
- Department of Medical Physics and Biomedical Engineering, University College London, London WC1E 6BT, UK
- Wellcome/EPSRC Centre for Interventional and Surgical Sciences, University College London, London W1W 7TY, UK
| | - Simeon J. West
- Department of Anaesthesia, University College Hospital, London NW1 2BU, UK
| | - Sanjayan Sathasivam
- Department of Chemistry, University College London, London WC1H 0AJ, UK or
- School of Engineering, London South Bank University, London SE1 0AA, UK
| | | | - Paul Collier
- Johnson Matthey Technology Centre, Reading RG4 9NH, UK
| | - Tom Vercauteren
- School of Biomedical Engineering and Imaging Sciences, King’s College London, London SE1 7EH, UK
| | - Adrien E. Desjardins
- Department of Medical Physics and Biomedical Engineering, University College London, London WC1E 6BT, UK
- Wellcome/EPSRC Centre for Interventional and Surgical Sciences, University College London, London W1W 7TY, UK
| | - Sacha Noimark
- Department of Medical Physics and Biomedical Engineering, University College London, London WC1E 6BT, UK
- Wellcome/EPSRC Centre for Interventional and Surgical Sciences, University College London, London W1W 7TY, UK
| | - Wenfeng Xia
- School of Biomedical Engineering and Imaging Sciences, King’s College London, London SE1 7EH, UK
| |
Collapse
|
24
|
Wu H, Zhou H, Zhang W, Jin P, Shi Q, Miao Z, Wang H, Zha Z. Three birds with one stone: co-encapsulation of diclofenac and DL-menthol for realizing enhanced energy deposition, glycolysis inhibition and anti-inflammation in HIFU surgery. J Nanobiotechnology 2022; 20:215. [PMID: 35524259 PMCID: PMC9074192 DOI: 10.1186/s12951-022-01437-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2021] [Accepted: 04/25/2022] [Indexed: 01/12/2023] Open
Abstract
Despite attracting increasing attention in clinic, non-invasive high-intensity focused ultrasound (HIFU) surgery still commonly suffers from tumor recurrence and even matastasis due to the generation of thermo-resistance in non-apoptotic tumor cells and adverse therapy-induced inflammation with enhanced secretion of growth factors in irradiated region. In this work, inspired by the intrinsic property that the expression of thermo-resistant heat shock proteins (HSPs) is highly dependent with adenosine triphosphate (ATP), dual-functionalized diclofenac (DC) with anti-inflammation and glycolysis-inhibition abilities was successfully co-encapsulated with phase-change dl-menthol (DLM) in poly(lactic-co-glycolic acid) nanoparticles (DC/DLM@PLGA NPs) to realize improved HIFU surgery without causing adverse inflammation. Both in vitro and in vivo studies demonstrated the great potential of DC/DLM@PLGA NPs for serving as an efficient synergistic agent for HIFU surgery, which can not only amplify HIFU ablation efficacy through DLM vaporization-induced energy deposition but also simultaneously sensitize tumor cells to hyperthermia by glycolysis inhibition as well as diminished inflammation. Thus, our study provides an efficient strategy for simultaneously improving the curative efficiency and diminishing the harmful inflammatory responses of clinical HIFU surgery.
Collapse
Affiliation(s)
- Haitao Wu
- School of Food and Biological Engineering, School of Instrument Science and Opto-Electronics Engineering, Hefei University of Technology, Anhui, 230009, Hefei, China
| | - Hu Zhou
- Shenzhen Maternity and Child Healthcare Hospital, The First School of Clinical Medicine, Southern Medical University, Shenzhen, 518028, Guangdong, China
| | - Wenjie Zhang
- School of Food and Biological Engineering, School of Instrument Science and Opto-Electronics Engineering, Hefei University of Technology, Anhui, 230009, Hefei, China
| | - Ping Jin
- Shenzhen Maternity and Child Healthcare Hospital, The First School of Clinical Medicine, Southern Medical University, Shenzhen, 518028, Guangdong, China.
| | - Qianqian Shi
- School of Food and Biological Engineering, School of Instrument Science and Opto-Electronics Engineering, Hefei University of Technology, Anhui, 230009, Hefei, China
| | - Zhaohua Miao
- School of Food and Biological Engineering, School of Instrument Science and Opto-Electronics Engineering, Hefei University of Technology, Anhui, 230009, Hefei, China
| | - Hua Wang
- Department of Oncology, Inflammation and Immune Mediated Diseases Laboratory of Anhui Province, The First Affiliated Hospital of Anhui Medical University, Hefei, 230022, Anhui, China.
| | - Zhengbao Zha
- School of Food and Biological Engineering, School of Instrument Science and Opto-Electronics Engineering, Hefei University of Technology, Anhui, 230009, Hefei, China.
| |
Collapse
|
25
|
Peek AT, Thomas GPL, Leotta DF, Yuldashev PV, Khokhlova VA, Khokhlova TD. Robust and durable aberrative and absorptive phantom for therapeutic ultrasound applications. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2022; 151:3007. [PMID: 35649925 PMCID: PMC9071501 DOI: 10.1121/10.0010369] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
Phase aberration induced by soft tissue inhomogeneities often complicates high-intensity focused ultrasound (HIFU) therapies by distorting the field and, previously, we designed and fabricated a bilayer gel phantom to reproducibly mimic that effect. A surface pattern containing size scales relevant to inhomogeneities of a porcine body wall was introduced between gel materials with fat- and muscle-like acoustic properties-ballistic and polyvinyl alcohol gels. Here, the phantom design was refined to achieve relevant values of ultrasound absorption and scattering and make it more robust, facilitating frequent handling and use in various experimental arrangements. The fidelity of the interfacial surface of the fabricated phantom to the design was confirmed by three-dimensional ultrasound imaging. The HIFU field distortions-displacement of the focus, enlargement of the focal region, and reduction of focal pressure-produced by the phantom were characterized using hydrophone measurements with a 1.5 MHz 256-element HIFU array and found to be similar to those induced by an ex vivo porcine body wall. A phase correction approach was used to mitigate the aberration effect on nonlinear focal waveforms and enable boiling histotripsy treatments through the phantom or body wall. The refined phantom represents a practical tool to explore HIFU therapy systems capabilities.
Collapse
Affiliation(s)
- Alex T Peek
- Center for Industrial and Medical Ultrasound, Applied Physics Laboratory, University of Washington, 1013 NE 40th Street, Seattle, Washington 98105, USA
| | - Gilles P L Thomas
- Center for Industrial and Medical Ultrasound, Applied Physics Laboratory, University of Washington, 1013 NE 40th Street, Seattle, Washington 98105, USA
| | - Daniel F Leotta
- Center for Industrial and Medical Ultrasound, Applied Physics Laboratory, University of Washington, 1013 NE 40th Street, Seattle, Washington 98105, USA
| | | | - Vera A Khokhlova
- Center for Industrial and Medical Ultrasound, Applied Physics Laboratory, University of Washington, 1013 NE 40th Street, Seattle, Washington 98105, USA
| | - Tatiana D Khokhlova
- Division of Gastroenterology, Department of Medicine, University of Washington, Seattle, Washington 98125, USA
| |
Collapse
|
26
|
Karagiannis E, Strouthos I, Leczynski A, Zamboglou N, Ferentinos K. Narrative Review of High-Dose-Rate Interstitial Brachytherapy in Primary or Secondary Liver Tumors. Front Oncol 2022; 12:800920. [PMID: 35299745 PMCID: PMC8920984 DOI: 10.3389/fonc.2022.800920] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2021] [Accepted: 01/31/2022] [Indexed: 12/24/2022] Open
Abstract
The optimal management of intrahepatic malignancies involves a multidisciplinary approach. Although surgical resection has been considered the only curative approach, the use of several minimally invasive ablative techniques has dramatically increased the last two decades, mainly due to the fact that they provide similar oncological results with significantly decreased morbidity. Among these modalities, interstitial liver brachytherapy, probably the most flexible liver ablative method, with excellent clinical data on its safety and effectiveness, is frequently not even mentioned as an option in the current peer reviewed literature and guidelines. Brachytherapy is a type of radiotherapy utilizing radionuclides that are directly inserted into the tumor. Compared to external beam radiation therapy, brachytherapy has the potential to deliver an ablative radiation dose over a short period of time, with the advantage of a rapid dose fall-off, that allows for sparing of adjacent healthy tissue. For numerous malignancies such as skin, gynecological, breast, prostate, head and neck, bladder, liver and soft-tissue tumors, brachytherapy as a monotherapy or combined with external beam radiation therapy, has become a standard treatment for many decades. This review article aims to describe the high-dose-rate liver brachytherapy technique, its selection criteria, present its advantages and disadvantages, as well as the available clinical data, in order to help physicians to explore and hopefully introduce liver brachytherapy into their clinical routine.
Collapse
Affiliation(s)
- Efstratios Karagiannis
- Department of Radiation Oncology, German Oncology Center, Limassol, Cyprus.,Department of Medicine, School of Medicine, European University Cyprus, Nicosia, Cyprus
| | - Iosif Strouthos
- Department of Radiation Oncology, German Oncology Center, Limassol, Cyprus.,Department of Medicine, School of Medicine, European University Cyprus, Nicosia, Cyprus
| | - Agnes Leczynski
- Department of Radiation Oncology, German Oncology Center, Limassol, Cyprus
| | - Nikolaos Zamboglou
- Department of Radiation Oncology, German Oncology Center, Limassol, Cyprus.,Department of Medicine, School of Medicine, European University Cyprus, Nicosia, Cyprus
| | - Konstantinos Ferentinos
- Department of Radiation Oncology, German Oncology Center, Limassol, Cyprus.,Department of Medicine, School of Medicine, European University Cyprus, Nicosia, Cyprus
| |
Collapse
|
27
|
Applications of Focused Ultrasound in the Treatment of Genitourinary Cancers. Cancers (Basel) 2022; 14:cancers14061536. [PMID: 35326687 PMCID: PMC8945954 DOI: 10.3390/cancers14061536] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2022] [Revised: 03/15/2022] [Accepted: 03/15/2022] [Indexed: 11/17/2022] Open
Abstract
Simple Summary Cancer is a prevalent disease globally, and conventional treatment options have been associated with substantial morbidity for patients. The unique acoustic properties and biological effects of focused ultrasound have been investigated for use as an alternative treatment option for various forms of cancer with lower associated morbidity than standard treatments. The objective of our review was to assess the current state and various applications of focused ultrasound for the treatment of genitourinary cancers, including prostate, kidney, bladder, penile, and testicular malignancies. Current research demonstrates that focused ultrasound-based focal therapy shows promise for the treatment of localized prostate and kidney cancer, and the effect of ultrasound on cell membranes may increase the efficacy of chemotherapeutics and radiotherapy. Focused ultrasound-based treatment modalities should continue to be investigated as an alternative or complementary treatment option for cancer patients. Abstract Traditional cancer treatments have been associated with substantial morbidity for patients. Focused ultrasound offers a novel modality for the treatment of various forms of cancer which may offer effective oncological control and low morbidity. We performed a review of PubMed articles assessing the current applications of focused ultrasound in the treatment of genitourinary cancers, including prostate, kidney, bladder, penile, and testicular cancer. Current research indicates that high-intensity focused ultrasound (HIFU) focal therapy offers effective short-term oncologic control of localized prostate and kidney cancer with lower associated morbidity than radical surgery. In addition, studies in mice have demonstrated that focused ultrasound treatment increases the accuracy of chemotherapeutic drug delivery, the efficacy of drug uptake, and cytotoxic effects within targeted cancer cells. Ultrasound-based therapy shows promise for the treatment of genitourinary cancers. Further research should continue to investigate focused ultrasound as an alternative cancer treatment option or as a complement to increase the efficacy of conventional treatments such as chemotherapy and radiotherapy.
Collapse
|
28
|
Kwizera EA, Stewart S, Mahmud MM, He X. Magnetic Nanoparticle-Mediated Heating for Biomedical Applications. JOURNAL OF HEAT TRANSFER 2022; 144:030801. [PMID: 35125512 PMCID: PMC8813031 DOI: 10.1115/1.4053007] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/01/2021] [Revised: 11/03/2021] [Indexed: 05/17/2023]
Abstract
Magnetic nanoparticles, especially superparamagnetic nanoparticles (SPIONs), have attracted tremendous attention for various biomedical applications. Facile synthesis and functionalization together with easy control of the size and shape of SPIONS to customize their unique properties, have made it possible to develop different types of SPIONs tailored for diverse functions/applications. More recently, considerable attention has been paid to the thermal effect of SPIONs for the treatment of diseases like cancer and for nanowarming of cryopreserved/banked cells, tissues, and organs. In this mini-review, recent advances on the magnetic heating effect of SPIONs for magnetothermal therapy and enhancement of cryopreservation of cells, tissues, and organs, are discussed, together with the non-magnetic heating effect (i.e., high Intensity focused ultrasound or HIFU-activated heating) of SPIONs for cancer therapy. Furthermore, challenges facing the use of magnetic nanoparticles in these biomedical applications are presented.
Collapse
Affiliation(s)
- Elyahb Allie Kwizera
- Fischell Department of Bioengineering, University of Maryland, 8278 Paint Branch Drive, College Park, MD 20742
| | - Samantha Stewart
- Fischell Department of Bioengineering, University of Maryland, 8278 Paint Branch Drive, College Park, MD 20742
| | - Md Musavvir Mahmud
- Fischell Department of Bioengineering, University of Maryland, 8278 Paint Branch Drive, College Park, MD 20742
| | - Xiaoming He
- Fischell Department of Bioengineering, University of Maryland, 8278 Paint Branch Drive, College Park, MD 20742; Marlene and Stewart Greenebaum Comprehensive Cancer Center, University of Maryland, Baltimore, MD 21201
| |
Collapse
|
29
|
New Perspectives for Eye-Sparing Treatment Strategies in Primary Uveal Melanoma. Cancers (Basel) 2021; 14:cancers14010134. [PMID: 35008296 PMCID: PMC8750035 DOI: 10.3390/cancers14010134] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2021] [Revised: 12/20/2021] [Accepted: 12/23/2021] [Indexed: 12/22/2022] Open
Abstract
Simple Summary Uveal melanoma is the most common intraocular cancer. The current eye-sparing treatment options include mostly plaque brachytherapy. However, the effectiveness of these methods is still unsatisfactory. In this article, we review several possible new treatment options. These methods may be based on the physical destruction of the cancerous cells by applying ultrasounds. Another approach may be based on improving the penetration of the anti-cancer agents. It seems that the most promising technologies from this group are based on enhancing drug delivery by applying electric current. Finally, new advanced nanoparticles are developed to combine diagnostic imaging and therapy (i.e., theranostics). However, these methods are mostly at an early stage of development. More advanced studies on experimental animals and clinical trials would be needed to introduce some of these techniques to routine clinical practice. Abstract Uveal melanoma is the most common intraocular malignancy and arises from melanocytes in the choroid, ciliary body, or iris. The current eye-sparing treatment options include surgical treatment, plaque brachytherapy, proton beam radiotherapy, stereotactic photon radiotherapy, or photodynamic therapy. However, the efficacy of these methods is still unsatisfactory. This article reviews several possible new treatment options and their potential advantages in treating localized uveal melanoma. These methods may be based on the physical destruction of the cancerous cells by applying ultrasounds. Two examples of such an approach are High-Intensity Focused Ultrasound (HIFU)—a promising technology of thermal destruction of solid tumors located deep under the skin and sonodynamic therapy (SDT) that induces reactive oxygen species. Another approach may be based on improving the penetration of anti-cancer agents into UM cells. The most promising technologies from this group are based on enhancing drug delivery by applying electric current. One such approach is called transcorneal iontophoresis and has already been shown to increase the local concentration of several different therapeutics. Another technique, electrically enhanced chemotherapy, may promote drug delivery from the intercellular space to cells. Finally, new advanced nanoparticles are developed to combine diagnostic imaging and therapy (i.e., theranostics). However, these methods are mostly at an early stage of development. More advanced and targeted preclinical studies and clinical trials would be needed to introduce some of these techniques to routine clinical practice.
Collapse
|
30
|
Sabuncu S, Yildirim A. Gas-stabilizing nanoparticles for ultrasound imaging and therapy of cancer. NANO CONVERGENCE 2021; 8:39. [PMID: 34851458 PMCID: PMC8636532 DOI: 10.1186/s40580-021-00287-2] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/22/2021] [Accepted: 11/05/2021] [Indexed: 05/06/2023]
Abstract
The use of ultrasound in the clinic has been long established for cancer detection and image-guided tissue biopsies. In addition, ultrasound-based methods have been widely explored to develop more effective cancer therapies such as localized drug delivery, sonodynamic therapy, and focused ultrasound surgery. Stabilized fluorocarbon microbubbles have been in use as contrast agents for ultrasound imaging in the clinic for several decades. It is also known that microbubble cavitation could generate thermal, mechanical, and chemical effects in the tissue to improve ultrasound-based therapies. However, the large size, poor stability, and short-term cavitation activity of microbubbles limit their applications in cancer imaging and therapy. This review will focus on an alternative type of ultrasound responsive material; gas-stabilizing nanoparticles, which can address the limitations of microbubbles with their nanoscale size, robustness, and high cavitation activity. This review will be of interest to researchers who wish to explore new agents to develop improved methods for molecular ultrasound imaging and therapy of cancer.
Collapse
Affiliation(s)
- Sinan Sabuncu
- CEDAR, Knight Cancer Institute, School of Medicine, Oregon Health & Science University, Portland, OR, 97201, USA
| | - Adem Yildirim
- CEDAR, Knight Cancer Institute, School of Medicine, Oregon Health & Science University, Portland, OR, 97201, USA.
| |
Collapse
|
31
|
A Review of High-Intensity Focused Ultrasound in Urology. Cancers (Basel) 2021; 13:cancers13225696. [PMID: 34830852 PMCID: PMC8616438 DOI: 10.3390/cancers13225696] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2021] [Revised: 11/08/2021] [Accepted: 11/10/2021] [Indexed: 01/20/2023] Open
Abstract
This review provides an introduction to high-intensity focused ultrasound (HIFU) and reviews its historical and current use in urological surgery. Current and historical literature (1927-2020), including that describing trials and review articles in the medical and ultrasonic literature, has been reviewed, using Pub Med and Cochrane search engines. HIFU is currently one of a number of treatments for prostate cancer, both as a primary treatment that can be repeated, and as a salvage treatment post-radiotherapy. HIFU is not yet sufficiently mature to be a standard treatment for renal cancer or other urological diseases, although there has been some success in early clinical trials. As the technology improves, this situation is likely to change. HIFU has been understood as a concept for a century, and has been applied in experimental use for half that time. It is now an accepted treatment with low morbidity in many diseases outside the scope of this review. In urological surgery, prostate HIFU is accepted as a localised treatment in selected cases, with potentially fewer side effects than other localised therapies. Currently the treatment for renal cancer is hindered by the perinephric fat and the position of the kidneys behind the ribs; however, as the technology improves with image fusion, faster treatments, and the ability with phased array transducers and motion compensation to overcome the problems caused by the ribs and breathing, successful treatment of kidney tumours will become more of a reality. In due course, there will be a new generation of machines for treating prostate cancer. These devices will further minimise the side effects of radical treatment of prostate cancer.
Collapse
|
32
|
She C, Li S, Wang X, Lu X, Liang H, Liu X. High-intensity focused ultrasound ablation as an adjuvant surgical salvage procedure in gestational trophoblastic neoplasia chemotherapy with chemoresistance or recurrence: two case reports. Int J Hyperthermia 2021; 38:1584-1589. [PMID: 34732086 DOI: 10.1080/02656736.2021.1998659] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022] Open
Abstract
BACKGROUND Chemotherapy is the main treatment strategy for gestational trophoblastic neoplasia (GTN). Surgical resection is crucial to deal with chemoresistance and recurrence following chemotherapy. The aim of this study was to explore if high-intensity focused ultrasound (HIFU) can be used as a complementary technique to surgical procedures in the management of GTN. CASE REPORT This case report described two females who previously developed chemoresistance or recurrence during chemotherapy and then underwent HIFU as an adjuvant surgical salvage procedure. For high-risk GTN patients with chemoresistance, HIFU treatment decreased the risk of chemoresistance and shortened the course of chemotherapy. It also reduced the dosage of chemotherapeutic agents used for the patient who suffered a recurrence. CONCLUSION For patients with GTN who desire to preserve their uterus, HIFU may be used as a complementary technique to surgical resection in the management of GTN.
Collapse
Affiliation(s)
- Chaokun She
- Department of Laboratory Medicine, The First People's Hospital of Zunyi (The Third Affiliated Hospital of Zunyi Medical University), Zunyi City, China
| | - Sha Li
- Department of Gynecology and Obstetrics, The First People's Hospital of Zunyi (The Third Affiliated Hospital of Zunyi Medical University), Zunyi City, China
| | - Xiaojun Wang
- Department of Clinical Medicine, Zunyi Medical and Pharmaceutical College, Zunyi City, China
| | - Xianghui Lu
- Department of Gynecology and Obstetrics, The First People's Hospital of Zunyi (The Third Affiliated Hospital of Zunyi Medical University), Zunyi City, China
| | - Hao Liang
- Department of Gynecology, Chongqing Haifu Hospital, Chongqing, China
| | - Xiaoyun Liu
- Department of Gynecology and Obstetrics, The First People's Hospital of Zunyi (The Third Affiliated Hospital of Zunyi Medical University), Zunyi City, China
| |
Collapse
|
33
|
Liao Q, Yang F, Xiong B, Zheng X, Wang Y, Qian J, Qiao Z, Huang J. Optimal Strategy for HIFU-Based Renal Sympathetic Denervation in Canines. Front Cardiovasc Med 2021; 8:739560. [PMID: 34722673 PMCID: PMC8551579 DOI: 10.3389/fcvm.2021.739560] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2021] [Accepted: 09/07/2021] [Indexed: 11/30/2022] Open
Abstract
Background: The association between the treatment efficacy and safety of high-intensity focused ultrasound (HIFU)-based renal sympathetic denervation (RDN) and the acoustic energy dose applied has not been fully studied and may provide important understanding of the mechanism that led to failure of the WAVE IV trial. The objective of this study was to externally deliver different HIFU doses to canines for RDN treatment and to investigate the optimal energy dose for HIFU-based RDN. Methods: Thirty canines were divided into five RDN groups according to dose of acoustic energy applied, and a sham control group that consisted of four canines was used for comparisons. All animals in the RDN groups underwent the RDN procedure with different acoustic energy doses, while in the sham control group, renal arteries were harvested without being subjected to acoustic energy delivery and were imaged using color Doppler flow imaging (CDFI). Blood pressure (BP) was recorded, and blood samples were collected before the RDN procedure and at 28 days after the RDN procedure. Histological examinations and measurement of renal tissue norepinephrine concentration were performed in all retrieved samples. Results: Suppression of BP was significant in the 300 W (15.17/8.33 ± 1.47/1.21 mmHg), 250 W (14.67/9.33 ± 1.21/1.37 mmHg), and 200 W (13.17/9.17 ± 2.32/1.84 mmHg) groups. Semiquantitative histological assessment of periarterial nerves around the kidney revealed that target nerves in the 300 W (9.77 ± 0.63), 250 W (9.42 ± 0.67), and 200 W (9.58 ± 0.54) groups had the highest nerve injury scores, followed by the 150 W group (5.29 ± 0.62). Furthermore, decreased renal tissue norepinephrine concentration, together with decreased expression of tyrosine hydroxylase in the 300, 250, and 200 W groups demonstrated effective sympathetic depression following sufficient acoustic energy deposition. However, the renal artery injury score in the 300 W group (0.93 ± 0.13) was significantly higher than in the other groups (p < 0.001). Conclusion: This study provides evidence that RDN effectiveness is based on the energy dose delivered and that 200–250 W is effective and safe in normal-sized canines.
Collapse
Affiliation(s)
- Qingyao Liao
- Department of Cardiology, The Second Affiliated Hospital of Chongqing Medical University, Chongqing, China
| | - Fang Yang
- Department of Cardiology, The Second Affiliated Hospital of Chongqing Medical University, Chongqing, China
| | - Bo Xiong
- Department of Cardiology, The Second Affiliated Hospital of Chongqing Medical University, Chongqing, China
| | - Xiaoyu Zheng
- Department of Clinical Medicine, Chongqing Medical and Pharmaceutical College, Chongqing, China
| | - Yue Wang
- Ultrasonic Technology Center, Institute of Acoustics, Chinese Academy of Sciences, Beijing, China
| | - Jun Qian
- Department of Cardiology, The Second Affiliated Hospital of Chongqing Medical University, Chongqing, China
| | - Zhao Qiao
- Department of Cardiology, The Second Affiliated Hospital of Chongqing Medical University, Chongqing, China
| | - Jing Huang
- Department of Cardiology, The Second Affiliated Hospital of Chongqing Medical University, Chongqing, China
| |
Collapse
|
34
|
Dong T, Jiang J, Zhang H, Liu H, Zou X, Niu J, Mao Y, Zhu M, Chen X, Li Z, Chen Y, Shi C, Yang X. PFP@PLGA/Cu 12Sb 4S 13-mediated PTT ablates hepatocellular carcinoma by inhibiting the RAS/MAPK/MT-CO1 signaling pathway. NANO CONVERGENCE 2021; 8:29. [PMID: 34606010 PMCID: PMC8490557 DOI: 10.1186/s40580-021-00279-2] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/14/2021] [Accepted: 09/10/2021] [Indexed: 05/11/2023]
Abstract
Hepatocellular carcinoma (HCC) is one of the most malignant tumors in the world, and patients with HCC face a poor prognosis. The conventional therapeutic strategies for HCC have undergone a challenge-riddled evolution owing to side effects and unsatisfactory efficacy. Here, aiming to provide a new method of HCC elimination, we formulated a novel multifunctional nanocapsule (PFP@PLGA/Cu12Sb4S13, PPCu) with applications in contrast-enhanced ultrasound imaging (CEUS) and photothermal therapy (PTT). These PPCu were successfully constructed with an average diameter of 346 nm (polydispersity index, PDI = 0.276). The reinforced contrast ratio of these PPCu was determined by CEUS, revealing their promising applications in image-guided monitoring of HCC treatment. Furthermore, the excellent photoabsorption and biocompatibility indicated by organ H&E staining indicated that PPCu meet quality expectations for use as photothermal transduction agent (PTA). PPCu treatment at 50 °C and higher temperatures efficiently repressed the proliferation, induced the apoptosis and decreased the motility of HCC cells. These effects might have been results of RAS/MAPK/MT-CO1 signaling pathway inhibition. In summary, PPCu were constructed to integrate CEUS and PTT successfully into therapy, which can lead to HCC elimination through RAS/MAPK/MT-CO1 signaling pathway repression.
Collapse
Affiliation(s)
- Tianxiu Dong
- Department of Abdominal Ultrasound, The First Affiliated Hospital of Harbin Medical University, Harbin, 150001, China
| | - Jian Jiang
- Department of Abdominal Ultrasound, The First Affiliated Hospital of Harbin Medical University, Harbin, 150001, China
| | - Hao Zhang
- Department of Abdominal Ultrasound, The First Affiliated Hospital of Harbin Medical University, Harbin, 150001, China
- Department of Medical Imaging, Heilongjiang Provincial Hospital, Harbin, 150001, China
| | - Hongyuan Liu
- Department of Abdominal Ultrasound, The First Affiliated Hospital of Harbin Medical University, Harbin, 150001, China
| | - Xiaomeng Zou
- Department of Abdominal Ultrasound, The First Affiliated Hospital of Harbin Medical University, Harbin, 150001, China
| | - Jiamei Niu
- Department of Abdominal Ultrasound, The First Affiliated Hospital of Harbin Medical University, Harbin, 150001, China
| | - Yingxuan Mao
- Department of Abdominal Ultrasound, The First Affiliated Hospital of Harbin Medical University, Harbin, 150001, China
| | - Mingwei Zhu
- Department of Abdominal Ultrasound, The First Affiliated Hospital of Harbin Medical University, Harbin, 150001, China
| | - Xi Chen
- Department of Abdominal Ultrasound, The First Affiliated Hospital of Harbin Medical University, Harbin, 150001, China
| | - Zizhuo Li
- Department of Abdominal Ultrasound, The First Affiliated Hospital of Harbin Medical University, Harbin, 150001, China
| | - Yaodong Chen
- Department of Ultrasonic Imaging, First Hospital of Shanxi Medical University, Taiyuan, 030001, China
| | - Chunying Shi
- Department of Radiology, The First Affiliated Hospital of Harbin Medical University, Harbin, 150001, China
| | - Xiuhua Yang
- Department of Abdominal Ultrasound, The First Affiliated Hospital of Harbin Medical University, Harbin, 150001, China.
| |
Collapse
|
35
|
Zheng Y, Chen L, Liu M, Wu J, Yu R, Lv F. Prediction of Clinical Outcome for High-Intensity Focused Ultrasound Ablation of Uterine Leiomyomas Using Multiparametric MRI Radiomics-Based Machine Leaning Model. Front Oncol 2021; 11:618604. [PMID: 34567999 PMCID: PMC8461183 DOI: 10.3389/fonc.2021.618604] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2020] [Accepted: 08/11/2021] [Indexed: 12/12/2022] Open
Abstract
Objectives This study sought to develop a multiparametric MRI radiomics-based machine learning model for the preoperative prediction of clinical success for high-intensity-focused ultrasound (HIFU) ablation of uterine leiomyomas. Methods One hundred and thirty patients who received HIFU ablation therapy for uterine leiomyomas were enrolled in this retrospective study. Radiomics features were extracted from T2-weighted (T2WI) image and ADC map derived from diffusion-weighted imaging (DWI). Three feature selection algorithms including least absolute shrinkage and selection operator (LASSO), recursive feature elimination (RFE), and ReliefF algorithm were used to select radiomics features, respectively, which were fed into four machine learning classifiers including k-nearest neighbors (KNN), logistic regression (LR), random forest (RF), and support vector machine (SVM) for the construction of outcome prediction models before HIFU treatment. The performance, predication ability, and clinical usefulness of these models were verified and evaluated using receiver operating characteristics (ROC), calibration, and decision curve analyses. Results The radiomics analysis provided an effective preoperative prediction for HIFU ablation of uterine leiomyomas. Using SVM with ReliefF algorithm, the multiparametric MRI radiomics model showed the favorable performance with average accuracy of 0.849, sensitivity of 0.814, specificity of 0.896, positive predictive value (PPV) of 0.903, negative predictive value (NPV) of 0.823, and the area under the ROC curve (AUC) of 0.887 (95% CI = 0.848-0.939) in fivefold cross-validation, followed by RF with ReliefF. Calibration and decision curve analyses confirmed the potential of model in predication ability and clinical usefulness. Conclusions The radiomics-based machine learning model can predict preoperatively HIFU ablation response for the patients with uterine leiomyomas and contribute to determining individual treatment strategies.
Collapse
Affiliation(s)
- Yineng Zheng
- Department of Radiology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China.,State Key Laboratory of Ultrasound in Medicine and Engineering, Chongqing Medical University, Chongqing, China
| | - Liping Chen
- Department of Radiology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China
| | - Mengqi Liu
- Department of Radiology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China
| | - Jiahui Wu
- Department of Radiology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China
| | - Renqiang Yu
- Department of Radiology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China
| | - Fajin Lv
- Department of Radiology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China.,State Key Laboratory of Ultrasound in Medicine and Engineering, Chongqing Medical University, Chongqing, China
| |
Collapse
|
36
|
Palumbo P, Daffinà J, Bruno F, Arrigoni F, Splendiani A, Di Cesare E, Barile A, Masciocchi C. Basics in Magnetic Resonance guided Focused Ultrasound: technical basis and clinical application. A brief overview. ACTA BIO-MEDICA : ATENEI PARMENSIS 2021; 92:e2021403. [PMID: 34505842 PMCID: PMC8477067 DOI: 10.23750/abm.v92is5.11881] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/07/2021] [Accepted: 07/28/2021] [Indexed: 11/30/2022]
Abstract
First applications of high focused ultrasound as intracranial ablative therapy were firstly described in early 50’. Since then, the technological innovations have shown an increasingly safe and effective face of this technique. And in the last few years, Magnetic Resonance (MR) guided Focused Ultrasound (gFUS) has become a valid minimally invasive technique in the treatment of several diseases, from bone tumors to symptomatic uterine fibroids or essential tremors. MR guidance, through the tomographic view, offers the advantage of an accurate target detection and treatment planning. Moreover, real-time monitoring sequences allow to avoid non-target ablation. An adequate knowledge of FUS is essential to understand its clinical effectiveness. Therefore, this brief review aims to debate the physical characteristics of US and the main fields of clinical application.
Collapse
Affiliation(s)
- Pierpaolo Palumbo
- Department of Diagnostic Imaging, area of Cardiovascular and Interventional Imaging, Abruzzo Health Unit 1, Italy and Italian Society of Medical and Interventional Radiology (SIRM), SIRM Foundation, Milan, Italy.
| | - Julia Daffinà
- Department of Biotechnological and Applied Clinical Sciences, University of L'Aquila, L'Aquila, Italy.
| | - Federico Bruno
- Department of Biotechnological and Applied Clinical Sciences, University of L'Aquila, L'Aquila, Italy and Italian Society of Medical and Interventional Radiology (SIRM), SIRM Foundation, Milan, Italy.
| | - Francesco Arrigoni
- Department of Biotechnological and Applied Clinical Sciences, University of L'Aquila, L'Aquila, Italy.
| | - Alessandra Splendiani
- Department of Biotechnological and Applied Clinical Sciences, University of L'Aquila, L'Aquila, Italy.
| | - Ernesto Di Cesare
- Department of Clinical Medicine, Public Health, Life and Environmental Science, University of L'Aquila, L'Aquila, Italy.
| | - Antonio Barile
- Department of Biotechnological and Applied Clinical Sciences, University of L'Aquila, L'Aquila, Italy.
| | - Carlo Masciocchi
- Department of Biotechnological and Applied Clinical Sciences, University of L'Aquila, L'Aquila, Italy.
| |
Collapse
|
37
|
Ponomarchuk EM, Rosnitskiy PB, Khokhlova TD, Buravkov SV, Tsysar SA, Karzova MM, Tumanova KD, Kunturova AV, Wang YN, Sapozhnikov OA, Trakhtman PE, Starostin NN, Khokhlova VA. Ultrastructural Analysis of Volumetric Histotripsy Bio-effects in Large Human Hematomas. ULTRASOUND IN MEDICINE & BIOLOGY 2021; 47:2608-2621. [PMID: 34116880 PMCID: PMC8355095 DOI: 10.1016/j.ultrasmedbio.2021.05.002] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/24/2020] [Revised: 04/28/2021] [Accepted: 05/02/2021] [Indexed: 06/12/2023]
Abstract
Large-volume soft tissue hematomas are a serious clinical problem, which, if untreated, can have severe consequences. Current treatments are associated with significant pain and discomfort. It has been reported that in an in vitro bovine hematoma model, pulsed high-intensity focused ultrasound (HIFU) ablation, termed histotripsy, can be used to rapidly and non-invasively liquefy the hematoma through localized bubble activity, enabling fine-needle aspiration. The goals of this study were to evaluate the efficiency and speed of volumetric histotripsy liquefaction using a large in vitro human hematoma model. Large human hematoma phantoms (85 cc) were formed by recalcifying blood anticoagulated with citrate phosphate dextrose/saline-adenine-glucose-mannitol solution. Typical boiling histotripsy pulses (10 or 2 ms) or hybrid histotripsy pulses using higher-amplitude and shorter pulses (0.4 ms) were delivered at 1% duty cycle while continuously translating the HIFU focus location. Histotripsy exposures were performed under ultrasound guidance with a 1.5-MHz transducer (8-cm aperture, F# = 0.75). The volume of liquefied lesions was determined by ultrasound imaging and gross inspection. Untreated hematoma samples and samples of the liquefied lesions aspirated using a fine needle were analyzed cytologically and ultrastructurally with scanning electron microscopy. All exposures resulted in uniform liquid-filled voids with sharp edges; liquefaction speed was higher for exposures with shorter pulses and higher shock amplitudes at the focus (up to 0.32, 0.68 and 2.62 mL/min for 10-, 2- and 0.4-ms pulses, respectively). Cytological and ultrastructural observations revealed completely homogenized blood cells and fibrin fragments in the lysate. Most of the fibrin fragments were less than 20 μm in length, but a number of fragments were up to 150 μm. The lysate with residual debris of that size would potentially be amenable to fine-needle aspiration without risk for needle clogging in clinical implementation.
Collapse
Affiliation(s)
- Ekaterina M Ponomarchuk
- Laboratory for Industrial and Medical Ultrasound, Physics Faculty, M. V. Lomonosov Moscow State University, Moscow, Russian Federation.
| | - Pavel B Rosnitskiy
- Laboratory for Industrial and Medical Ultrasound, Physics Faculty, M. V. Lomonosov Moscow State University, Moscow, Russian Federation
| | | | - Sergey V Buravkov
- Faculty of Fundamental Medicine, M. V. Lomonosov Moscow State University, Moscow, Russian Federation
| | - Sergey A Tsysar
- Laboratory for Industrial and Medical Ultrasound, Physics Faculty, M. V. Lomonosov Moscow State University, Moscow, Russian Federation
| | - Maria M Karzova
- Laboratory for Industrial and Medical Ultrasound, Physics Faculty, M. V. Lomonosov Moscow State University, Moscow, Russian Federation
| | - Kseniya D Tumanova
- Laboratory for Industrial and Medical Ultrasound, Physics Faculty, M. V. Lomonosov Moscow State University, Moscow, Russian Federation
| | - Anna V Kunturova
- Laboratory for Industrial and Medical Ultrasound, Physics Faculty, M. V. Lomonosov Moscow State University, Moscow, Russian Federation
| | - Y-N Wang
- Center for Industrial and Medical Ultrasound, Applied Physics Laboratory, University of Washington, Seattle, Washington, USA
| | - Oleg A Sapozhnikov
- Laboratory for Industrial and Medical Ultrasound, Physics Faculty, M. V. Lomonosov Moscow State University, Moscow, Russian Federation; Center for Industrial and Medical Ultrasound, Applied Physics Laboratory, University of Washington, Seattle, Washington, USA
| | - Pavel E Trakhtman
- National Medical Research Center for Pediatric Hematology, Oncology and Immunology, Moscow, Russian Federation
| | - Nicolay N Starostin
- National Medical Research Center for Pediatric Hematology, Oncology and Immunology, Moscow, Russian Federation
| | - Vera A Khokhlova
- Laboratory for Industrial and Medical Ultrasound, Physics Faculty, M. V. Lomonosov Moscow State University, Moscow, Russian Federation; Center for Industrial and Medical Ultrasound, Applied Physics Laboratory, University of Washington, Seattle, Washington, USA
| |
Collapse
|
38
|
Thomas GPL, Khokhlova TD, Khokhlova VA. Partial Respiratory Motion Compensation for Abdominal Extracorporeal Boiling Histotripsy Treatments With a Robotic Arm. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2021; 68:2861-2870. [PMID: 33905328 PMCID: PMC8513721 DOI: 10.1109/tuffc.2021.3075938] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
Extracorporeal boiling histotripsy (BH), a noninvasive method for mechanical tissue disintegration, is getting closer to clinical applications. However, the motion of the targeted organs, mostly resulting from the respiratory motion, reduces the efficiency of the treatment. Here, a practical and affordable unidirectional respiratory motion compensation method for BH is proposed and evaluated in ex vivo tissues. The BH transducer is fixed on a robotic arm following the motion of the skin, which is tracked using an inline ultrasound imaging probe. In order to compensate for system lags and obtain a more accurate compensation, an autoregressive motion prediction model is implemented. BH pulse gating is also implemented to ensure targeting accuracy. The system is then evaluated with ex vivo BH treatments of tissue samples undergoing motion simulating breathing with the movement of amplitudes between 5 and 10 mm, the frequency between 16 and 18 breaths/min, and a maximum speed of 14.2 mm/s. Results show a reduction of at least 89% of the value of the targeting error during treatment while only increasing the treatment time by no more than 1%. The lesions obtained by treating with the motion compensation were close in size and affected area to the no-motion case, whereas lesions obtained without the compensation were often incomplete and had larger affected areas. This approach to motion compensation could benefit extracorporeal BH and other histotripsy methods in clinical translation.
Collapse
|
39
|
Zhang W, Zhang L. Introduction to a special issue of the International Journal of Hyperthermia: "the status and prospects of the clinical applications of high intensity focused ultrasound". Int J Hyperthermia 2021; 38:1-4. [PMID: 34420441 DOI: 10.1080/02656736.2021.1962985] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022] Open
Affiliation(s)
- Wendy Zhang
- Department of Radiology, Zucker School of Medicine at Hofstra Northwell, Staten Island University Hospital, Staten Island, NY, USA
| | - Lian Zhang
- Chongqing Haifu Hospital, Chongqing, China.,State Key Laboratory of Ultrasound in Medicine and Engineering, College of Biomedical Engineering, Chongqing Medical University, Chongqing, China.,Chongqing Key Laboratory of Biomedical Engineering, Chongqing Medical University, Chongqing, China
| |
Collapse
|
40
|
Prachee I, Wu F, Cranston D. Oxford's clinical experience in the development of high intensity focused ultrasound therapy. Int J Hyperthermia 2021; 38:81-88. [PMID: 34420448 DOI: 10.1080/02656736.2021.1899311] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023] Open
Abstract
High Intensity Focused Ultrasound (HIFU) capably bridges the disciplines of surgery, oncology and biomedical engineering science. It provides the precision associated with a surgical tool whilst remaining a truly non-invasive technique. Oxford has been a centre for both clinical and preclinical research in HIFU over the last twenty years. Research into this technology in the UK has a longer history, with much of the early research being carried out by Professor Gail ter Haar and her team at the Institute of Cancer Research at Sutton in Surrey. A broad range of potential applications have been explored extending from tissue ablation to novel drug delivery. This review presents Oxford's clinical studies and applications for the development of this non-invasive therapy. This includes treatment of solid abdominal tumours comprising those of the liver, kidney, uterus, pancreas, pelvis and prostate. It also briefly introduces preclinical and translational works that are currently being undertaken at the Institute of Biomedical Engineering, University of Oxford. The safety, wide tolerability and effectiveness of this technology is comprehensively demonstrated across these studies. These results can facilitate the incorporation of HIFU as a key clinical management strategy.
Collapse
Affiliation(s)
- Ishika Prachee
- Green Templeton College, University of Oxford, Oxford, UK.,Oxford University Hospitals NHS Foundation Trust, Oxford, UK
| | - Feng Wu
- Oxford University Hospitals NHS Foundation Trust, Oxford, UK.,Nuffield Department of Surgical Sciences, University of Oxford, Oxford, UK.,State Key Laboratory of Ultrasound Engineering in Medicine, Chongqing, China
| | - David Cranston
- Green Templeton College, University of Oxford, Oxford, UK.,Oxford University Hospitals NHS Foundation Trust, Oxford, UK.,Nuffield Department of Surgical Sciences, University of Oxford, Oxford, UK
| |
Collapse
|
41
|
Kumari S, Sharma N, Sahi SV. Advances in Cancer Therapeutics: Conventional Thermal Therapy to Nanotechnology-Based Photothermal Therapy. Pharmaceutics 2021; 13:1174. [PMID: 34452135 PMCID: PMC8398544 DOI: 10.3390/pharmaceutics13081174] [Citation(s) in RCA: 41] [Impact Index Per Article: 13.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2021] [Revised: 07/21/2021] [Accepted: 07/23/2021] [Indexed: 12/21/2022] Open
Abstract
In this review, advancement in cancer therapy that shows a transition from conventional thermal therapies to laser-based photothermal therapies is discussed. Laser-based photothermal therapies are gaining popularity in cancer therapeutics due to their overall outcomes. In photothermal therapy, light is converted into heat to destruct the various types of cancerous growth. The role of nanoparticles as a photothermal agent is emphasized in this review article. Magnetic, as well as non-magnetic, nanoparticles have been effectively used in the photothermal-based cancer therapies. The discussion includes a critical appraisal of in vitro and in vivo, as well as the latest clinical studies completed in this area. Plausible evidence suggests that photothermal therapy is a promising avenue in the treatment of cancer.
Collapse
Affiliation(s)
- Sangeeta Kumari
- Department of Biological Sciences, University of the Sciences, Philadelphia, PA 19104-4495, USA
| | - Nilesh Sharma
- Department of Biology, Western Kentucky University, 1906 College Heights Boulevard, Bowling Green, KY 42101-1080, USA;
| | - Shivendra V. Sahi
- Department of Biological Sciences, University of the Sciences, Philadelphia, PA 19104-4495, USA
| |
Collapse
|
42
|
Komolibus K, Fisher C, Swartling J, Svanberg S, Svanberg K, Andersson-Engels S. Perspectives on interstitial photodynamic therapy for malignant tumors. JOURNAL OF BIOMEDICAL OPTICS 2021; 26:JBO-210111-PERR. [PMID: 34302323 PMCID: PMC8299827 DOI: 10.1117/1.jbo.26.7.070604] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/06/2021] [Accepted: 07/08/2021] [Indexed: 05/17/2023]
Abstract
SIGNIFICANCE Despite remarkable advances in the core modalities used in combating cancer, malignant diseases remain the second largest cause of death globally. Interstitial photodynamic therapy (IPDT) has emerged as an alternative approach for the treatment of solid tumors. AIM The aim of our study is to outline the advancements in IPDT in recent years and provide our vision for the inclusion of IPDT in standard-of-care (SoC) treatment guidelines of specific malignant diseases. APPROACH First, the SoC treatment for solid tumors is described, and the attractive properties of IPDT are presented. Second, the application of IPDT for selected types of tumors is discussed. Finally, future opportunities are considered. RESULTS Strong research efforts in academic, clinical, and industrial settings have led to significant improvements in the current implementation of IPDT, and these studies have demonstrated the unique advantages of this modality for the treatment of solid tumors. It is envisioned that further randomized prospective clinical trials and treatment optimization will enable a wide acceptance of IPDT in the clinical community and inclusion in SoC guidelines for well-defined clinical indications. CONCLUSIONS The minimally invasive nature of this treatment modality combined with the relatively mild side effects makes IPDT a compelling alternative option for treatment in a number of clinical applications. The adaptability of this technique provides many opportunities to both optimize and personalize the treatment.
Collapse
Affiliation(s)
- Katarzyna Komolibus
- Tyndall National Institute, Biophotonics@Tyndall, IPIC, Cork, Ireland
- Address all correspondence to Katarzyna Komolibus,
| | - Carl Fisher
- Tyndall National Institute, Biophotonics@Tyndall, IPIC, Cork, Ireland
| | | | - Sune Svanberg
- Lund University, Department of Physics, Lund, Sweden
- South China Normal University, South China Academy of Advanced Optoelectronics, Guangzhou, China
| | - Katarina Svanberg
- South China Normal University, South China Academy of Advanced Optoelectronics, Guangzhou, China
- Lund University Hospital, Department of Clinical Sciences, Lund, Sweden
| | - Stefan Andersson-Engels
- Tyndall National Institute, Biophotonics@Tyndall, IPIC, Cork, Ireland
- University College Cork, Department of Physics, Cork, Ireland
| |
Collapse
|
43
|
Kok HP, Cressman ENK, Ceelen W, Brace CL, Ivkov R, Grüll H, Ter Haar G, Wust P, Crezee J. Heating technology for malignant tumors: a review. Int J Hyperthermia 2021; 37:711-741. [PMID: 32579419 DOI: 10.1080/02656736.2020.1779357] [Citation(s) in RCA: 147] [Impact Index Per Article: 49.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022] Open
Abstract
The therapeutic application of heat is very effective in cancer treatment. Both hyperthermia, i.e., heating to 39-45 °C to induce sensitization to radiotherapy and chemotherapy, and thermal ablation, where temperatures beyond 50 °C destroy tumor cells directly are frequently applied in the clinic. Achievement of an effective treatment requires high quality heating equipment, precise thermal dosimetry, and adequate quality assurance. Several types of devices, antennas and heating or power delivery systems have been proposed and developed in recent decades. These vary considerably in technique, heating depth, ability to focus, and in the size of the heating focus. Clinically used heating techniques involve electromagnetic and ultrasonic heating, hyperthermic perfusion and conductive heating. Depending on clinical objectives and available technology, thermal therapies can be subdivided into three broad categories: local, locoregional, or whole body heating. Clinically used local heating techniques include interstitial hyperthermia and ablation, high intensity focused ultrasound (HIFU), scanned focused ultrasound (SFUS), electroporation, nanoparticle heating, intraluminal heating and superficial heating. Locoregional heating techniques include phased array systems, capacitive systems and isolated perfusion. Whole body techniques focus on prevention of heat loss supplemented with energy deposition in the body, e.g., by infrared radiation. This review presents an overview of clinical hyperthermia and ablation devices used for local, locoregional, and whole body therapy. Proven and experimental clinical applications of thermal ablation and hyperthermia are listed. Methods for temperature measurement and the role of treatment planning to control treatments are discussed briefly, as well as future perspectives for heating technology for the treatment of tumors.
Collapse
Affiliation(s)
- H Petra Kok
- Department of Radiation Oncology, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands
| | - Erik N K Cressman
- Department of Interventional Radiology, The University of Texas MD Anderson Cancer Center, Houston, TX, USA
| | - Wim Ceelen
- Department of GI Surgery, Ghent University Hospital, Ghent, Belgium
| | - Christopher L Brace
- Department of Radiology and Biomedical Engineering, University of Wisconsin-Madison, Madison, WI, USA
| | - Robert Ivkov
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Baltimore, MD, USA.,Department of Oncology, Johns Hopkins University School of Medicine, Baltimore, MD, USA.,Department of Mechanical Engineering, Whiting School of Engineering, Johns Hopkins University, Baltimore, MD, USA.,Department of Materials Science and Engineering, Whiting School of Engineering, Johns Hopkins University, Baltimore, MD, USA
| | - Holger Grüll
- Department of Diagnostic and Interventional Radiology, Faculty of Medicine, University Hospital of Cologne, University of Cologne, Cologne, Germany
| | - Gail Ter Haar
- Department of Physics, The Institute of Cancer Research, London, UK
| | - Peter Wust
- Department of Radiation Oncology, Charité Universitätsmedizin Berlin, Berlin, Germany
| | - Johannes Crezee
- Department of Radiation Oncology, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands
| |
Collapse
|
44
|
Chang S, Na H, Koo M, Choi T, Kim Y, Park SA, Lee SK, Park J. Therapeutic Quadrisected Annular Array for Improving Magnetic Resonance Compatibility. IEEE Trans Biomed Eng 2021; 69:199-208. [PMID: 34156933 DOI: 10.1109/tbme.2021.3090986] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
OBJECTIVE Focused ultrasound has been applied in brain therapeutics. Although focusing ultrasonic beams on multiple arbitrary regions under the guidance of magnetic resonance imaging(MRI) is needed for precise treatments, current therapeutic transducers with large pitch sizes have been optimized to focus on deep brain regions. While annular arrays can adjust the beam foci from cortical to deep regions, their circular shape may generate eddy current-induced magnetic flux during MRI. In this study, a quadrisected annular array is proposed to address these limitations. METHODS Conventional and quadrisected annular arrays with three elements were implemented by loading the electrode patterns onto an 850 kHz 1-3 composite PZT disc, with a diameter of 31 mm, including three rings. MR compatibilities were demonstrated by imaging an MRI phantom with pulse sequences for B0 and B1 mapping and spin-echo imaging. Acoustic beam profiles, with and without a macaque monkey skull, were measured. A quadrisected transducer was also used to open the blood-brain barrier(BBB). RESULTS The flip angle distortion improved by 20% in spin-echo MR imaging. The acoustic beam distortions shifting the focal point from 36 to 41mm and elongating the focal zone from 10 to 15 mm could be recovered to nearly the original values. BBB openings in the hippocampus and basal region were also demonstrated. CONCLUSION The MR compatibility was improved by the increased resistance of the electrodes in the quadrisected array maintaining dynamic focusing capabilities. SIGNIFICANCE The quadrisected annular design can be a fundamental structure for a larger MR-compatible segmented array transducer generating multiple acoustic foci.
Collapse
|
45
|
Sadeghi-Goughari M, Jeon S, Kwon HJ. Carbon nanotube-mediated high intensity focused ultrasound. NANO FUTURES 2021. [DOI: 10.1088/2399-1984/abfebc] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Abstract
High intensity focused ultrasound (HIFU) is emerging as a novel therapeutic technique for cancer treatment through a hyperthermal mechanism using ultrasound. However, collateral thermal damages to healthy tissue and skin burns due to the use of high levels of ultrasonic energy during HIFU treatment remain major challenges to clinical application. The main objective of the current study is to evaluate the potential of carbon nanotubes (CNTs) as effective absorption-enhancing agents for HIFU to mediate the heating process at low ultrasonic power levels, and consequently upgrade hyperthermal therapeutic effects of HIFU. An experimental study using in vitro tissue phantoms was conducted to assess the effects of CNTs on HIFU’s heating mechanism. Detailed information was extracted from the experiments for thermal analysis, including rate of absorbed energy density and temperature rise profile at the focal region. Parametric studies were carried out, revealing the effects of ultrasound parameters (ultrasonic power and driving frequency) on the performance of CNTs in various concentrations. The results indicated that CNTs significantly enhanced the thermal effect of HIFU by elevating energy absorption rate and consequential temperature rise. Moreover, it was demonstrated that an increase in ultrasonic power and driving frequency could lead to a better performance of CNTs during HIFU ablation procedures; the effects of CNTs could be further enhanced by increasing their volume concentration inside the medium.
Collapse
|
46
|
Tsai KWK, Chen JC, Lai HC, Chang WC, Taira T, Chang JW, Wei CY. The Distribution of Skull Score and Skull Density Ratio in Tremor Patients for MR-Guided Focused Ultrasound Thalamotomy. Front Neurosci 2021; 15:612940. [PMID: 34079434 PMCID: PMC8165389 DOI: 10.3389/fnins.2021.612940] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2020] [Accepted: 04/08/2021] [Indexed: 12/20/2022] Open
Abstract
Objective Magnetic resonance-guided focused ultrasound (MRgFUS) is a minimum-invasive surgical approach to non-incisionally cause the thermos-coagulation inside the human brain. The skull score (SS) has already been approved as one of the most dominant factors related to a successful MRgFUS treatment. In this study, we first reveal the SS distribution of the tremor patients, and correlate the SS with the image feature from customized skull density ratio (cSDR). This correlation might give a direction to future clinical studies for improving the SS. Methods Two hundred and forty-six patients received a computed tomography (CT) scan of the brain, and a bone-enhanced filter was applied and reconstructed to a high spatial resolution CT images. The SS of all patients would be estimated by the MRgFUS system after importing the reconstructed CT images into the MRgFUS system. The histogram and the cumulative distribution of the SS from all the patients were calculated to show the percentage of the patients whose SS lower than 0.3 and 0.4. The same CT images of all patients were utilized to calculated the cSDR by first segmented the trabecular bone and the cortical bone from the CT images and divided the average trabecular bone intensity (aTBI) by the average cortical bone intensity (aCBI). The Pearson’s correlations between the SS and the cSDR, aTBI, and the aCBI were calculated, respectively. Results There were 19.19 and 50% of the patient who had the SS lower than the empirical threshold 0.3 and 0.4, respectively. The Pearson’s correlation between the SS and the cSDR, aCBI, and the aTBI were R = 0.8145, 0.5723, and 0.8842. Conclusion Half of the patients were eligible for the MRgFUS thalamotomy based on the SS, and nearly 20% of patients were empirically difficult to achieve a therapeutic temperature during MRgFUS. The SS and our cSDR are highly correlated, and the SS had a higher correlation with aTBI than with aCBI. This is the first report to explicitly reveal the SS population and indicate a potential way to increase the chance to achieve a therapeutic temperature for those who originally have low SS.
Collapse
Affiliation(s)
- Kevin Wen-Kai Tsai
- MR-guided Focused Ultrasound Center, Chang Bing Show Chwan Memorial Hospital, Changhua City, Taiwan
| | - Jui-Cheng Chen
- Neuroscience Laboratory, Department of Neurology, China Medical University Hospital, Taichung City, Taiwan.,School of Medicine, College of Medicine, China Medical University, Taichung City, Taiwan.,Department of Neurology, China Medical University Hsinchu Hospital, Hsinchu, Taiwan
| | - Hui-Chin Lai
- MR-guided Focused Ultrasound Center, Chang Bing Show Chwan Memorial Hospital, Changhua City, Taiwan
| | - Wei-Chieh Chang
- MR-guided Focused Ultrasound Center, Chang Bing Show Chwan Memorial Hospital, Changhua City, Taiwan.,Department of Neurosurgery, Chang Bing Show Chwan Memorial Hospital, Changhua City, Taiwan
| | - Takaomi Taira
- Department of Neurosurgery, Tokyo Women's Medical University, Tokyo, Japan
| | - Jin Woo Chang
- Department of Neurosurgery, Yonsei University College of Medicine, Seoul, South Korea
| | - Cheng-Yu Wei
- Department of Exercise and Health Promotion, College of Kinesiology and Health, Chinese Culture University, Taipei, Taiwan.,Department of Neurology, Chang Bing Show Chwan Memorial Hospital, Changhua City, Taiwan
| |
Collapse
|
47
|
Lyon PC, Mannaris C, Gray M, Carlisle R, Gleeson FV, Cranston D, Wu F, Coussios CC. Large-Volume Hyperthermia for Safe and Cost-Effective Targeted Drug Delivery Using a Clinical Ultrasound-Guided Focused Ultrasound Device. ULTRASOUND IN MEDICINE & BIOLOGY 2021; 47:982-997. [PMID: 33451816 DOI: 10.1016/j.ultrasmedbio.2020.12.008] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/03/2020] [Revised: 12/03/2020] [Accepted: 12/10/2020] [Indexed: 06/12/2023]
Abstract
Lyso-thermosensitive liposomes (LTSLs) are specifically designed to release chemotherapy agents under conditions of mild hyperthermia. Preclinical studies have indicated that magnetic resonance (MR)-guided focused ultrasound (FUS) systems can generate well-controlled volumetric hyperthermia using real-time thermometry. However, high-throughput clinical translation of these approaches for drug delivery is challenging, not least because of the significant cost overhead of MR guidance and the much larger volumes that need to be heated clinically. Using an ultrasound-guided extracorporeal clinical FUS device (Chongqing HAIFU, JC200) with thermistors in a non-perfused ex vivo bovine liver tissue model with ribs, we present an optimised strategy for rapidly inducing (5-15 min) and sustaining (>30 min) mild hyperthermia (ΔT <+4°C) in large tissue volumes (≤92 cm3). We describe successful clinical translation in a first-in-human clinical trial of targeted drug delivery of LTSLs (TARDOX: a phase I study to investigate drug release from thermosensitive liposomes in liver tumours), in which targeted tumour hyperthermia resulted in localised chemo-ablation. The heating strategy is potentially applicable to other indications and ultrasound-guided FUS devices.
Collapse
Affiliation(s)
- Paul Christopher Lyon
- Institute of Biomedical Engineering, University of Oxford, Oxford, UK; Nuffield Department of Surgical Sciences, Oxford, UK; Department of Radiology, Oxford University Hospitals NHS Foundation Trust, Oxford, UK.
| | | | - Michael Gray
- Institute of Biomedical Engineering, University of Oxford, Oxford, UK
| | - Robert Carlisle
- Institute of Biomedical Engineering, University of Oxford, Oxford, UK
| | - Fergus V Gleeson
- Department of Radiology, Oxford University Hospitals NHS Foundation Trust, Oxford, UK
| | | | - Feng Wu
- Nuffield Department of Surgical Sciences, Oxford, UK
| | | |
Collapse
|
48
|
Hu H, Feng W, Qian X, Yu L, Chen Y, Li Y. Emerging Nanomedicine-Enabled/Enhanced Nanodynamic Therapies beyond Traditional Photodynamics. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2021; 33:e2005062. [PMID: 33565157 DOI: 10.1002/adma.202005062] [Citation(s) in RCA: 111] [Impact Index Per Article: 37.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/24/2020] [Revised: 08/25/2020] [Indexed: 05/18/2023]
Abstract
The rapid knowledge growth of nanomedicine and nanobiotechnology enables and promotes the emergence of distinctive disease-specific therapeutic modalities, among which nanomedicine-enabled/augmented nanodynamic therapy (NDT), as triggered by either exogenous or endogenous activators on nanosensitizers, can generate reactive radicals for accomplishing efficient disease nanotherapies with mitigated side effects and endowed disease specificity. As one of the most representative modalities of NDT, traditional light-activated photodynamics suffers from the critical and unsurmountable issues of the low tissue-penetration depth of light and the phototoxicity of the photosensitizers. To overcome these obstacles, versatile nanomedicine-enabled/augmented NDTs have been explored for satisfying varied biomedical applications, which strongly depend on the physicochemical properties of the involved nanomedicines and nanosensitizers. These distinctive NDTs refer to sonodynamic therapy (SDT), thermodynamic therapy (TDT), electrodynamic therapy (EDT), piezoelectric dynamic therapy (PZDT), pyroelectric dynamic therapy (PEDT), radiodynamic therapy (RDT), and chemodynamic therapy (CDT). Herein, the critical roles, functions, and biological effects of nanomedicine (e.g., sonosensitizing, photothermal-converting, electronic, piezoelectric, pyroelectric, radiation-sensitizing, and catalytic properties) for enabling the therapeutic procedure of NDTs, are highlighted and discussed, along with the underlying therapeutic principle and optimization strategy for augmenting disease-therapeutic efficacy and biosafety. The present challenges and critical issues on the clinical translations of NDTs are also discussed and clarified.
Collapse
Affiliation(s)
- Hui Hu
- Medmaterial Research Center, Jiangsu University Affiliated People's Hospital, Zhenjiang, 212002, P. R. China
- Institute of Diagnostic and Interventional Radiology, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai, 200233, China
| | - Wei Feng
- School of Life Sciences, Shanghai University, Shanghai, 2000444, P. R. China
| | - Xiaoqin Qian
- Medmaterial Research Center, Jiangsu University Affiliated People's Hospital, Zhenjiang, 212002, P. R. China
| | - Luodan Yu
- School of Life Sciences, Shanghai University, Shanghai, 2000444, P. R. China
| | - Yu Chen
- School of Life Sciences, Shanghai University, Shanghai, 2000444, P. R. China
- State Key Laboratory of High Performance Ceramic and Superfine, Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai, 200050, P. R. China
| | - Yuehua Li
- Institute of Diagnostic and Interventional Radiology, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai, 200233, China
| |
Collapse
|
49
|
Lim HG, Kim H, Kim K, Park J, Kim Y, Yoo J, Heo D, Baik J, Park SM, Kim HH. Thermal Ablation and High-Resolution Imaging Using a Back-to-Back (BTB) Dual-Mode Ultrasonic Transducer: In Vivo Results. SENSORS (BASEL, SWITZERLAND) 2021; 21:1580. [PMID: 33668260 PMCID: PMC7956793 DOI: 10.3390/s21051580] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/13/2021] [Revised: 02/13/2021] [Accepted: 02/20/2021] [Indexed: 02/06/2023]
Abstract
We present a back-to-back (BTB) structured, dual-mode ultrasonic device that incorporates a single-element 5.3 MHz transducer for high-intensity focused ultrasound (HIFU) treatment and a single-element 20.0 MHz transducer for high-resolution ultrasound imaging. Ultrasound image-guided surgical systems have been developed for lesion monitoring to ensure that ultrasonic treatment is correctly administered at the right locations. In this study, we developed a dual-element transducer composed of two elements that share the same housing but work independently with a BTB structure, enabling a mode change between therapy and imaging via 180-degree mechanical rotation. The optic fibers were embedded in the HIFU focal region of ex vivo chicken breasts and the temperature change was measured. Images were obtained in vivo mice before and after treatment and compared to identify the treated region. We successfully acquired B-mode and C-scan images that display the hyperechoic region indicating coagulation necrosis in the HIFU-treated volume up to a depth of 10 mm. The compact BTB dual-mode ultrasonic transducer may be used for subcutaneous thermal ablation and monitoring, minimally invasive surgery, and other clinical applications, all with ultrasound only.
Collapse
Affiliation(s)
- Hae Gyun Lim
- Department of Biomedical Engineering, Pukyong National University, Busan 48513, Korea;
| | - Hyunhee Kim
- School of Interdisciplinary Bioscience and Bioengineering, Pohang University of Science and Technology, Pohang 37673, Korea; (H.K.); (J.P.); (J.Y.)
| | - Kyungmin Kim
- Department of Convergence IT Engineering, Pohang University of Science and Technology, Pohang 37673, Korea; (K.K.); (Y.K.); (J.B.); (S.-M.P.)
| | - Jeongwoo Park
- School of Interdisciplinary Bioscience and Bioengineering, Pohang University of Science and Technology, Pohang 37673, Korea; (H.K.); (J.P.); (J.Y.)
| | - Yeonggeun Kim
- Department of Convergence IT Engineering, Pohang University of Science and Technology, Pohang 37673, Korea; (K.K.); (Y.K.); (J.B.); (S.-M.P.)
| | - Jinhee Yoo
- School of Interdisciplinary Bioscience and Bioengineering, Pohang University of Science and Technology, Pohang 37673, Korea; (H.K.); (J.P.); (J.Y.)
| | - Dasom Heo
- Department of Mechanical Engineering, Pohang University of Science and Technology, Pohang 37673, Korea;
| | - Jinhwan Baik
- Department of Convergence IT Engineering, Pohang University of Science and Technology, Pohang 37673, Korea; (K.K.); (Y.K.); (J.B.); (S.-M.P.)
| | - Sung-Min Park
- Department of Convergence IT Engineering, Pohang University of Science and Technology, Pohang 37673, Korea; (K.K.); (Y.K.); (J.B.); (S.-M.P.)
| | - Hyung Ham Kim
- School of Interdisciplinary Bioscience and Bioengineering, Pohang University of Science and Technology, Pohang 37673, Korea; (H.K.); (J.P.); (J.Y.)
- Department of Convergence IT Engineering, Pohang University of Science and Technology, Pohang 37673, Korea; (K.K.); (Y.K.); (J.B.); (S.-M.P.)
- Department of Electrical Engineering, Pohang University of Science and Technology, Pohang 37673, Korea
| |
Collapse
|
50
|
Zubair M, Dickinson RJ. 3D synthetic aperture imaging with a therapeutic spherical random phased array for transcostal applications. Phys Med Biol 2021; 66:035024. [PMID: 33276351 DOI: 10.1088/1361-6560/abd0d0] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
Experimental validation of a synthetic aperture imaging technique using a therapeutic random phased array is described, demonstrating the dual nature of imaging and therapy of such an array. The transducer is capable of generating both continuous wave high intensity beams for ablating the tumor and low intensity ultrasound pulses to image the target area. Pulse-echo data is collected from the elements of the phased array to obtain B-mode images of the targets. Since therapeutic arrays are optimized for therapy only with concave apertures having low f-number and large directive elements often coarsely sampled, imaging can not be performed using conventional beamforming. We show that synthetic aperture imaging is capable of processing the acquired RF data to obtain images of the field of interest. Simulations were performed to compare different synthetic aperture imaging techniques to identify the best algorithm in terms of spatial resolution. Experimental validation was performed using a 1 MHz, 256-elements, spherical random phased array with 130 mm radius of curvature. The array was integrated with a research ultrasound scanner via custom connectors to acquire raw RF data for variety of targets. Imaging was implemented using synthetic aperture beamforming to produce images of a rib phantom and ex vivo ribs. The array was shown to resolve spherical targets within ±15 mm of either side of the axis in the focal plane and obtain 3D images of the rib phantom up to ±40 mm of either side of the central axis and at a depth of 3-9 cm from the array surface. The lateral and axial full width half maximum was 1.15 mm and 2.75 mm, respectively. This study was undertaken to emphasize that both therapy and image guidance with a therapeutic random phased array is possible and such a system has the potential to address some major limitations in the existing high intensity focused ultrasound (HIFU) systems. The 3D images obtained with a therapeutic array can be used to identify and locate strong scattering objects aiding to image guidance and treatment planning of the HIFU procedure.
Collapse
Affiliation(s)
- Muhammad Zubair
- Department of Bioengineering, Imperial College London, United Kingdom
| | | |
Collapse
|