1
|
Woon D, Qin S, Al-Khanaty A, Perera M, Lawrentschuk N. Imaging in Renal Cell Carcinoma Detection. Diagnostics (Basel) 2024; 14:2105. [PMID: 39335784 PMCID: PMC11431198 DOI: 10.3390/diagnostics14182105] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2024] [Revised: 09/09/2024] [Accepted: 09/13/2024] [Indexed: 09/30/2024] Open
Abstract
INTRODUCTION Imaging in renal cell carcinoma (RCC) is a constantly evolving landscape. The incidence of RCC has been rising over the years with the improvement in image quality and sensitivity in imaging modalities resulting in "incidentalomas" being detected. We aim to explore the latest advances in imaging for RCC. METHODS A literature search was conducted using Medline and Google Scholar, up to May 2024. For each subsection of the manuscript, a separate search was performed using a combination of the following key terms "renal cell carcinoma", "renal mass", "ultrasound", "computed tomography", "magnetic resonance imaging", "18F-Fluorodeoxyglucose PET/CT", "prostate-specific membrane antigen PET/CT", "technetium-99m sestamibi SPECT/CT", "carbonic anhydrase IX", "girentuximab", and "radiomics". Studies that were not in English were excluded. The reference lists of selected manuscripts were checked manually for eligible articles. RESULTS The main imaging modalities for RCC currently are ultrasound, computed tomography (CT) and magnetic resonance imaging (MRI). Contrast-enhanced US (CEUS) has emerged as an alternative to CT or MRI for the characterisation of renal masses. Furthermore, there has been significant research in molecular imaging in recent years, including FDG PET, PSMA PET/CT, 99mTc-Sestamibi, and anti-carbonic anhydrase IX monoclonal antibodies/peptides. Radiomics and the use of AI in radiology is a growing area of interest. CONCLUSIONS There will be significant change in the field of imaging in RCC as molecular imaging becomes increasingly popular, which reflects a shift in management to a more conservative approach, especially for small renal masses (SRMs). There is the hope that the improvement in imaging will result in less unnecessary invasive surgeries or biopsies being performed for benign or indolent renal lesions.
Collapse
Affiliation(s)
- Dixon Woon
- Department of Urology, Austin Health, Heidelberg, VIC 3084, Australia
- Department of Surgery, The University of Melbourne, Melbourne, VIC 3010, Australia
| | - Shane Qin
- Department of Urology, Austin Health, Heidelberg, VIC 3084, Australia
| | | | - Marlon Perera
- Department of Urology, Austin Health, Heidelberg, VIC 3084, Australia
- Division of Cancer Surgery, Peter MacCallum Cancer Centre, Melbourne, VIC 3000, Australia
| | - Nathan Lawrentschuk
- Department of Surgery, The University of Melbourne, Melbourne, VIC 3010, Australia
- Division of Cancer Surgery, Peter MacCallum Cancer Centre, Melbourne, VIC 3000, Australia
- Department of Urology, Royal Melbourne Hospital, Parkville, VIC 3052, Australia
| |
Collapse
|
2
|
Trovato P, Simonetti I, Morrone A, Fusco R, Setola SV, Giacobbe G, Brunese MC, Pecchi A, Triggiani S, Pellegrino G, Petralia G, Sica G, Petrillo A, Granata V. Scientific Status Quo of Small Renal Lesions: Diagnostic Assessment and Radiomics. J Clin Med 2024; 13:547. [PMID: 38256682 PMCID: PMC10816509 DOI: 10.3390/jcm13020547] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2023] [Revised: 01/05/2024] [Accepted: 01/16/2024] [Indexed: 01/24/2024] Open
Abstract
Background: Small renal masses (SRMs) are defined as contrast-enhanced renal lesions less than or equal to 4 cm in maximal diameter, which can be compatible with stage T1a renal cell carcinomas (RCCs). Currently, 50-61% of all renal tumors are found incidentally. Methods: The characteristics of the lesion influence the choice of the type of management, which include several methods SRM of management, including nephrectomy, partial nephrectomy, ablation, observation, and also stereotactic body radiotherapy. Typical imaging methods available for differentiating benign from malignant renal lesions include ultrasound (US), contrast-enhanced ultrasound (CEUS), computed tomography (CT), and magnetic resonance imaging (MRI). Results: Although ultrasound is the first imaging technique used to detect small renal lesions, it has several limitations. CT is the main and most widely used imaging technique for SRM characterization. The main advantages of MRI compared to CT are the better contrast resolution and tissue characterization, the use of functional imaging sequences, the possibility of performing the examination in patients allergic to iodine-containing contrast medium, and the absence of exposure to ionizing radiation. For a correct evaluation during imaging follow-up, it is necessary to use a reliable method for the assessment of renal lesions, represented by the Bosniak classification system. This classification was initially developed based on contrast-enhanced CT imaging findings, and the 2019 revision proposed the inclusion of MRI features; however, the latest classification has not yet received widespread validation. Conclusions: The use of radiomics in the evaluation of renal masses is an emerging and increasingly central field with several applications such as characterizing renal masses, distinguishing RCC subtypes, monitoring response to targeted therapeutic agents, and prognosis in a metastatic context.
Collapse
Affiliation(s)
- Piero Trovato
- Radiology Division, Istituto Nazionale Tumori-IRCCS-Fondazione G. Pascale, 80131 Naples, Italy; (P.T.); (I.S.); (S.V.S.); (A.P.); (V.G.)
| | - Igino Simonetti
- Radiology Division, Istituto Nazionale Tumori-IRCCS-Fondazione G. Pascale, 80131 Naples, Italy; (P.T.); (I.S.); (S.V.S.); (A.P.); (V.G.)
| | - Alessio Morrone
- Division of Radiology, Università degli Studi della Campania Luigi Vanvitelli, 80138 Naples, Italy;
| | - Roberta Fusco
- Medical Oncology Division, Igea SpA, 80013 Naples, Italy
- Italian Society of Medical and Interventional Radiology (SIRM), SIRM Foundation, Via della Signora 2, 20122 Milan, Italy
| | - Sergio Venanzio Setola
- Radiology Division, Istituto Nazionale Tumori-IRCCS-Fondazione G. Pascale, 80131 Naples, Italy; (P.T.); (I.S.); (S.V.S.); (A.P.); (V.G.)
| | - Giuliana Giacobbe
- General and Emergency Radiology Department, “Antonio Cardarelli” Hospital, 80131 Naples, Italy;
| | - Maria Chiara Brunese
- Diagnostic Imaging Section, Department of Medical and Surgical Sciences & Neurosciences, University of Molise, 86100 Campobasso, Italy;
| | - Annarita Pecchi
- Department of Radiology, University of Modena and Reggio Emilia, 41121 Modena, Italy;
| | - Sonia Triggiani
- Postgraduate School of Radiodiagnostics, University of Milan, 20122 Milan, Italy; (S.T.); (G.P.)
| | - Giuseppe Pellegrino
- Postgraduate School of Radiodiagnostics, University of Milan, 20122 Milan, Italy; (S.T.); (G.P.)
| | - Giuseppe Petralia
- Department of Medical Imaging and Radiation Sciences, IEO European Institute of Oncology IRCCS, Via Ripamonti 435, 20141 Milan, Italy;
| | - Giacomo Sica
- Radiology Unit, Monaldi Hospital, Azienda Ospedaliera dei Colli, 80131 Naples, Italy;
| | - Antonella Petrillo
- Radiology Division, Istituto Nazionale Tumori-IRCCS-Fondazione G. Pascale, 80131 Naples, Italy; (P.T.); (I.S.); (S.V.S.); (A.P.); (V.G.)
| | - Vincenza Granata
- Radiology Division, Istituto Nazionale Tumori-IRCCS-Fondazione G. Pascale, 80131 Naples, Italy; (P.T.); (I.S.); (S.V.S.); (A.P.); (V.G.)
| |
Collapse
|
3
|
Schade KA, Mergen V, Sartoretti T, Alkadhi H, Euler A. Pseudoenhancement in Cystic Renal Lesions - Impact of Virtual Monoenergetic Images of Photon-Counting Detector CT on Lesion Classification. Acad Radiol 2023; 30 Suppl 1:S305-S313. [PMID: 37150736 DOI: 10.1016/j.acra.2023.04.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2023] [Revised: 03/30/2023] [Accepted: 04/03/2023] [Indexed: 05/09/2023]
Abstract
RATIONALE AND OBJECTIVES To investigate the impact of virtual monoenergetic images (VMI) from photon-counting detector CT (PCD-CT) on the enhancement and classification of renal cysts. MATERIALS AND METHODS Adults with renal cysts (≥7 mm) who received a triphasic examination on a clinical PCD-CT (120 kVp; IQ level 68) between July 2021 and March 2022 were retrospectively identified. Only non-enhancing cysts (enhancement<10 HU between unenhanced and venous phase at 70 keV) were included. VMI from 40 to 190 keV with increments of 10 keV were reconstructed from the venous phase. Enhancement was measured to classify each lesion as non-enhancing (<10 HU), equivocally enhancing (10-19 HU), and definitely enhancing (≥20 HU). Classification changes as a function of VMI were assessed. Pearson correlation coefficient, the Kruskal-Wallis and the Chi-square test were used. RESULTS A total of 86 patients (mean age, 74 ± 9 years; 74 male) with 160 non-enhancing renal cysts (17.6 ± 10 mm) were included. CT attenuation of the cysts increased from higher to lower VMI levels with a mean attenuation of 4 ± 11 HU at 190 keV to 36 ± 17 HU at 40 keV. Mean attenuation of the renal parenchyma was 43 ± 4 HU at 190 keV and 414 ± 71 HU at 40 keV. No cyst exhibited enhancement from 70 keV to 190 keV. At 40, 50, and 60 keV, 35% (56/160), 29% (47/160) and 9% (15/160) of cysts showed equivocal and 46% (74/160), 10% (16/160), and 0% (0/160) definite enhancement, respectively. There was no significant influence of size (P=.13), cyst location (P=.9) and BMI (P=.19) on enhancement classification. CONCLUSION VMI has a relevant impact on enhancement and classification of renal cysts with misclassification in a large number of cases at energy levels below 70 keV.
Collapse
Affiliation(s)
- Katharina Alexandra Schade
- Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland (K.A.S., V.M., T.S., H.A., A.E.)
| | - Victor Mergen
- Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland (K.A.S., V.M., T.S., H.A., A.E.)
| | - Thomas Sartoretti
- Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland (K.A.S., V.M., T.S., H.A., A.E.)
| | - Hatem Alkadhi
- Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland (K.A.S., V.M., T.S., H.A., A.E.)
| | - André Euler
- Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland (K.A.S., V.M., T.S., H.A., A.E.); Institute of Radiology, Kantonsspital Baden, Baden, Switzerland (A.E.).
| |
Collapse
|
4
|
Qarni B, McGrath T, Aldhufian M, Schieda N. Prevalence of malignant or possibly malignant renal masses among homogeneous low-attenuation masses that are too small to characterize at computed tomography. Abdom Radiol (NY) 2023; 48:2628-2635. [PMID: 37166461 DOI: 10.1007/s00261-023-03946-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2023] [Revised: 04/28/2023] [Accepted: 05/01/2023] [Indexed: 05/12/2023]
Abstract
BACKGROUND Homogeneous low-attenuation renal masses that are too small to characterize (tstc) are considered clinically insignificant; however, based primarily on expert opinion. OBJECTIVE To determine the prevalence of malignant or possibly malignant masses among homogeneous low-attenuation renal masses that are tstc. MATERIALS AND METHODS This retrospective cross-sectional study evaluated 75 patients with 104 tstc who underwent renal CT and MRI between Jan 2016 and Jul 2022. Low-attenuation renal masses measuring < 1 cm in size were identified and, independently evaluated by two blinded radiologists measuring attenuation (Hounsfield Units, HU) at non-contrast enhanced CT (NECT) and nephrographic phase contrast-enhanced (CE)-CT when possible. Reference standard for benign cyst was MRI and for other renal masses was pathology or MRI showing enhancement. RESULTS Average tstc size was 6 ± 2 (range 2-10) mm. Considering only incidental tstc (CT performed for another reason), 100% (98/98, 95%CI 96-100%) tstc were benign. Overall, considering both incidental and tstc referred for further characterization, there were 94% (98/104; 95% Confidence Intervals [CIs] 88-98%) benign cysts and 6% (6/104; 95%CI 2-12%) other masses (1 Bosniak 2F cystic mass, 2 probable renal cell carcinoma (RCC), three metastases). Pseudoenhancement, attenuation change > 10 HU or > 20 HU, was present in 29% (15/59) and 12% (7/59) benign cysts. All six other masses enhanced by > 20 HU. CECT threshold of ≤ 30 HU correctly classified 62% of benign cysts (61/98). All six other masses measured > 30 HU at CECT. CONCLUSION The prevalence of malignant or possibly malignant renal masses among homogeneous low-attenuation too small to characterize masses among incidental tstc masses is near zero. Attenuation measurements misclassify a substantial proportion of these cysts, likely due to their small size.
Collapse
Affiliation(s)
- Bilal Qarni
- Department of Medical Imaging, The Ottawa Hospital, 1053 Carling Avenue, Room C159, Ottawa, ON, K1Y 4E9, Canada
| | - Trevor McGrath
- Department of Medical Imaging, The Ottawa Hospital, 1053 Carling Avenue, Room C159, Ottawa, ON, K1Y 4E9, Canada
| | - Meshary Aldhufian
- Department of Medical Imaging, The Ottawa Hospital, 1053 Carling Avenue, Room C159, Ottawa, ON, K1Y 4E9, Canada
| | - Nicola Schieda
- Department of Medical Imaging, The Ottawa Hospital, 1053 Carling Avenue, Room C159, Ottawa, ON, K1Y 4E9, Canada.
| |
Collapse
|
5
|
Abstract
ABSTRACT Computed tomography (CT) images display anatomic structures across 3 dimensions and are highly quantitative; they are the reference standard for 3-dimensional geometric measurements and are used for 3-dimensional printing of anatomic models and custom implants, as well as for radiation therapy treatment planning. The pixel intensity in CT images represents the linear x-ray attenuation coefficient of the imaged materials after linearly scaling the coefficients into a quantity known as CT numbers that is conveyed in Hounsfield units. When measured with the same scanner model, acquisition, and reconstruction parameters, the mean CT number of a material is highly reproducible, and quantitative applications of CT scanning that rely on the measured CT number, such as for assessing bone mineral density or coronary artery calcification, are well established. However, the strong dependence of CT numbers on x-ray beam spectra limits quantitative applications and standardization from achieving robust widespread success. This article reviews several quantitative applications of CT and the challenges they face, and describes the benefits brought by photon-counting detector (PCD) CT technology. The discussed benefits of PCD-CT include that it is inherently multienergy, expands material decomposition capabilities, and improves spatial resolution and geometric quantification. Further, the utility of virtual monoenergetic images to standardize CT numbers is discussed, as virtual monoenergetic images can be the default image type in PCD-CT due to the full-time spectral nature of the technology.
Collapse
Affiliation(s)
- Cynthia H. McCollough
- Department of Radiology, Mayo Clinic, 200 First St SW Rochester, MN, United States 55905
| | - Kishore Rajendran
- Department of Radiology, Mayo Clinic, 200 First St SW Rochester, MN, United States 55905
| | - Shuai Leng
- Department of Radiology, Mayo Clinic, 200 First St SW Rochester, MN, United States 55905
| |
Collapse
|
6
|
Alrumayyan M, Raveendran L, Lawson KA, Finelli A. Cystic Renal Masses: Old and New Paradigms. Urol Clin North Am 2023; 50:227-238. [PMID: 36948669 DOI: 10.1016/j.ucl.2023.01.003] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/22/2023]
Abstract
Cystic renal masses describe a spectrum of lesions with benign and/or malignant features. Cystic renal masses are most often identified incidentally with the Bosniak classification system stratifying their malignant potential. Solid enhancing components most often represent clear cell renal cell carcinoma yet display an indolent natural history relative to pure solid renal masses. This has led to an increased adoption of active surveillance as a management strategy in those who are poor surgical candidates. This article provides a contemporary overview of historical and emerging clinical paradigms in the diagnosis and management of this distinct clinical entity.
Collapse
Affiliation(s)
- Majed Alrumayyan
- Division of Urology, Department of Surgery, Princess Margaret Cancer Centre, University Health Network, Toronto, Ontario, Canada
| | - Lucshman Raveendran
- Division of Urology, Department of Surgery, Princess Margaret Cancer Centre, University Health Network, Toronto, Ontario, Canada
| | - Keith A Lawson
- Division of Urology, Department of Surgery, Princess Margaret Cancer Centre, University Health Network, Toronto, Ontario, Canada
| | - Antonio Finelli
- Division of Urology, Department of Surgery, Princess Margaret Cancer Centre, University Health Network, Toronto, Ontario, Canada.
| |
Collapse
|
7
|
Kim JH, Choe J, Kim HK, Lee HY. MRI-Based Stepwise Approach to Anterior Mediastinal Cystic Lesions for Diagnosis and Further Management. Korean J Radiol 2023; 24:62-78. [PMID: 36606621 PMCID: PMC9830146 DOI: 10.3348/kjr.2022.0606] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2022] [Revised: 10/06/2022] [Accepted: 10/22/2022] [Indexed: 01/03/2023] Open
Abstract
As the majority of incidentally detected lesions in the anterior mediastinum is small nodules with soft tissue appearance, the differential diagnosis has typically included thymic neoplasm and prevascular lymph node, with benign cyst. Overestimation or misinterpretation of these lesions can lead to unnecessary surgery for ultimately benign conditions. nonsurgical anterior mediastinal lesions. The pitfalls of MRI evaluation for anterior mediastinal cystic lesions are as follows: first, we acknowledge the limitation of T2-weighted images for evaluating benign cystic lesions. Due to variable contents within benign cystic lesions, such as hemorrhage, T2 signal intensity may be variable. Second, owing to extensive necrosis and cystic changes, the T2 shine-through effect may be seen on diffusion-weighted images (DWI), and small solid portions might be missed on enhanced images. Therefore, both enhancement and DWI with apparent diffusion coefficient values should be considered. An algorithm will be suggested for the diagnostic evaluation of anterior mediastinal cystic lesions, and finally, a management strategy based on MRI features will be suggested.
Collapse
Affiliation(s)
- Jong Hee Kim
- Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Jooae Choe
- Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul, Korea
| | - Hong Kwan Kim
- Department of Thoracic and Cardiovascular Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Ho Yun Lee
- Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.
| |
Collapse
|
8
|
Wang C, Mao J, Yang S, Xie H, Wang S, Hu L. Thymic cyst: Is attenuation artifactually increased on contrast-enhanced CT? Front Oncol 2022; 12:984770. [DOI: 10.3389/fonc.2022.984770] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2022] [Accepted: 10/19/2022] [Indexed: 11/13/2022] Open
Abstract
BackgroundThymic cysts are often misinterpreted as thymomas or lymph nodes, then leading to unnecessary thymectomy. The purpose of this study was to investigate how the adjacent large vessels artifactually affected attenuation values of thymic cysts on contrast–enhanced CT (CE-CT).MethodsIn this retrospective study, a total of 84 patients were included with pathological diagnosis of thymic cysts and preoperative CE-CT. Quantitative measurements of the size, CT attenuation of thymic cysts and CT attenuation of adjacent large vessels were performed on preoperative CE-CT. According to the absolute change in attenuation of the cysts between contrast-enhanced and nonenhanced CT, the patients were classified into the groups of artifactual hyper-density, unchanged density, and artifactual hypo-density. CT characteristics were compared between the three groups. Furthermore, multivariable logistic regression analysis was performed to determine the independent factors for artifactual hyper-density.ResultsThe group of artifactual hyper-density had smaller short diameter of the cysts, higher postcontrast attenuation values and lower nonenhanced attenuation values of the adjacent large vessel. Furthermore, the multivariable logistic analysis showed that artifactual hyper-density of thymic cysts was negatively associated with nonenhanced attenuation of adjacent large vessel, and positively associated with postcontrast attenuation of adjacent large vessel and postcontrast attenuation of cysts.ConclusionsMost cases with >20 HU nonenhanced CT attenuation in surgically resected cases. Artifactual hyper-density─pseudo-enhancement phenomenon of thymic cysts was more apparent in higher increasing attenuation of adjacent large vessels on CE-CT. A well understanding of this phenomenon can help reduce preoperative misdiagnosis and unnecessary thymectomy.
Collapse
|
9
|
Smith ACJ, Tse JJ, Waungana TH, Bott KN, Kuczynski MT, Michalski AS, Boyd SK, Manske SL. Internal calibration for opportunistic computed tomography muscle density analysis. PLoS One 2022; 17:e0273203. [PMID: 36251648 PMCID: PMC9576101 DOI: 10.1371/journal.pone.0273203] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2022] [Accepted: 10/02/2022] [Indexed: 11/05/2022] Open
Abstract
INTRODUCTION Muscle weakness can lead to reduced physical function and quality of life. Computed tomography (CT) can be used to assess muscle health through measures of muscle cross-sectional area and density loss associated with fat infiltration. However, there are limited opportunities to measure muscle density in clinically acquired CT scans because a density calibration phantom, allowing for the conversion of CT Hounsfield units into density, is typically not included within the field-of-view. For bone density analysis, internal density calibration methods use regions of interest within the scan field-of-view to derive the relationship between Hounsfield units and bone density, but these methods have yet to be adapted for muscle density analysis. The objective of this study was to design and validate a CT internal calibration method for muscle density analysis. METHODOLOGY We CT scanned 10 bovine muscle samples using two scan protocols and five scan positions within the scanner bore. The scans were calibrated using internal calibration and a reference phantom. We tested combinations of internal calibration regions of interest (e.g., air, blood, bone, muscle, adipose). RESULTS We found that the internal calibration method using two regions of interest, air and adipose or blood, yielded accurate muscle density values (< 1% error) when compared with the reference phantom. The muscle density values derived from the internal and reference phantom calibration methods were highly correlated (R2 > 0.99). The coefficient of variation for muscle density across two scan protocols and five scan positions was significantly lower for internal calibration (mean = 0.33%) than for Hounsfield units (mean = 6.52%). There was no difference between coefficient of variation for the internal calibration and reference phantom methods. CONCLUSIONS We have developed an internal calibration method to produce accurate and reliable muscle density measures from opportunistic computed tomography images without the need for calibration phantoms.
Collapse
Affiliation(s)
- Ainsley C. J. Smith
- Biomedical Engineering Graduate Program, University of Calgary, Alberta, Canada
- Department of Radiology, Cumming School of Medicine, University of Calgary, Alberta, Canada
- McCaig Institute for Bone and Joint Health, University of Calgary, Alberta, Canada
| | - Justin J. Tse
- Department of Radiology, Cumming School of Medicine, University of Calgary, Alberta, Canada
- McCaig Institute for Bone and Joint Health, University of Calgary, Alberta, Canada
| | - Tadiwa H. Waungana
- Biomedical Engineering Graduate Program, University of Calgary, Alberta, Canada
- Department of Radiology, Cumming School of Medicine, University of Calgary, Alberta, Canada
- McCaig Institute for Bone and Joint Health, University of Calgary, Alberta, Canada
| | - Kirsten N. Bott
- Department of Radiology, Cumming School of Medicine, University of Calgary, Alberta, Canada
- McCaig Institute for Bone and Joint Health, University of Calgary, Alberta, Canada
| | - Michael T. Kuczynski
- Biomedical Engineering Graduate Program, University of Calgary, Alberta, Canada
- Department of Radiology, Cumming School of Medicine, University of Calgary, Alberta, Canada
- McCaig Institute for Bone and Joint Health, University of Calgary, Alberta, Canada
| | - Andrew S. Michalski
- Biomedical Engineering Graduate Program, University of Calgary, Alberta, Canada
- Department of Radiology, Cumming School of Medicine, University of Calgary, Alberta, Canada
- McCaig Institute for Bone and Joint Health, University of Calgary, Alberta, Canada
| | - Steven K. Boyd
- Biomedical Engineering Graduate Program, University of Calgary, Alberta, Canada
- Department of Radiology, Cumming School of Medicine, University of Calgary, Alberta, Canada
- McCaig Institute for Bone and Joint Health, University of Calgary, Alberta, Canada
| | - Sarah L. Manske
- Biomedical Engineering Graduate Program, University of Calgary, Alberta, Canada
- Department of Radiology, Cumming School of Medicine, University of Calgary, Alberta, Canada
- McCaig Institute for Bone and Joint Health, University of Calgary, Alberta, Canada
- * E-mail:
| |
Collapse
|
10
|
Editorial Comment: Pseudoenhancement-New Solutions to Old Problems? AJR Am J Roentgenol 2022; 219:633. [PMID: 35642768 DOI: 10.2214/ajr.22.28037] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
11
|
Effect of Ultra-High Resolution CT on Pseudoenhancement in Renal Cysts: A Phantom Experiment and Clinical Study. AJR Am J Roentgenol 2022; 219:624-633. [PMID: 35583427 DOI: 10.2214/ajr.22.27354] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Background: Ultra-high resolution CT (U-HRCT) allows acquisition using a small detector element size, in turn allowing very high spatial resolutions. The high resolution may reduce partial-volume averaging and thereby renal cyst pseudoenhancement. Objective: To assess the impact of U-HRCT on renal cyst pseudoenhancement. Methods: A phantom was constructed that contained 7-, 15-, and 25-mm simulated cysts within compartments simulating unenhanced and nephrographic-phase renal parenchyma. The phantom underwent two U-HRCT acquisitions using 0.25- and 0.5-mm detector elements, with reconstruction at varying matrices and slice thicknesses. A retrospective study was performed of 36 patients (24 men, 12 women; mean age, 75.7±9.4 years) with 118 renal cysts who underwent renal-mass protocol CT using U-HRCT and the 0.25-mm detector element, with reconstruction at varying matrices and slice thicknesses; detector element size could not be retrospectively adjusted. ROIs were placed to measure cysts' attenuation increase from unenhanced to nephrographic phases (to reflect pseudoenhancement), and SD of unenhanced-phase attenuation (to reflect image noise). Results: In the phantom, attenuation increase was lower for the 0.25 mm than 0.5 mm detector element for the 15-mm cyst (4.6±2.7 HU vs 6.8±2.9 HU, p=.03) and 25-mm cyst (2.3±1.4 HU vs 3.8±1.2 HU, p=.02), but not the 7-mm cyst (p=.72). Attenuation increase was not different between 512×512 and 1024×1024 matrices for any cyst size in the phantom or patients (p>.05). Attenuation increase was not associated with slice thickness for any cyst size in the phantom or for ≥5-to-<10 mm and ≥10 mm cysts in patients (p>.05). For cysts <5 mm in patients, attenuation increase showed decreases with thinner slices (3 mm: 23.7±22.5, 2 mm: 20.2±22.7 HU, 0.5 mm: 11.6±17.5 HU, 0.25 mm: 12.6±19.7 HU; p<.001). Smaller detector element size, increased matrix size, and thinner slices all increased image noise for cysts of all sizes in the phantom and patients (p<.05). Conclusion: U-HRCT may reduce renal cyst pseudoenhancement through a smaller detector element size and, for <5 mm cysts, very thin slices; however, these adjustments result in increased noise. Clinical Impact: Although requiring further clinical evaluation, U-HRCT may facilitate characterization of small cystic renal lesions, thereby reducing equivocal interpretations and follow-up recommendations.
Collapse
|
12
|
Tse JJ, Smith ACJ, Kuczynski MT, Kaketsis DA, Manske SL. Advancements in Osteoporosis Imaging, Screening, and Study of Disease Etiology. Curr Osteoporos Rep 2021; 19:532-541. [PMID: 34292468 DOI: 10.1007/s11914-021-00699-3] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 06/03/2021] [Indexed: 02/07/2023]
Abstract
PURPOSE OF REVIEW The purpose of this review is to inform researchers and clinicians with the most recent imaging techniques that are employed (1) to opportunistically screen for osteoporosis and (2) to provide a better understanding into the disease etiology of osteoporosis. RECENT FINDINGS Phantomless calibration techniques for computed tomography (CT) may pave the way for better opportunistic osteoporosis screening and the retroactive analysis of imaging data. Additionally, hardware advances are enabling new applications of dual-energy CT and cone-beam CT to the study of bone. Advances in MRI sequences are also improving imaging evaluation of bone properties. Finally, the application of image registration techniques is enabling new uses of imaging to investigate soft tissue-bone interactions as well as bone turnover. While DXA remains the most prominent imaging tool for osteoporosis diagnosis, new imaging techniques are becoming more widely available and providing additional information to inform clinical decision-making.
Collapse
Affiliation(s)
- Justin J Tse
- Department of Radiology, Cumming School of Medicine, University of Calgary, 3280 Hospital Dr NW, Calgary, AB, T2N 4Z6, Canada
- McCaig Institute for Bone and Joint Health, Cumming School of Medicine, University of Calgary, Calgary, AB, Canada
| | - Ainsley C J Smith
- Department of Radiology, Cumming School of Medicine, University of Calgary, 3280 Hospital Dr NW, Calgary, AB, T2N 4Z6, Canada
- McCaig Institute for Bone and Joint Health, Cumming School of Medicine, University of Calgary, Calgary, AB, Canada
- Biomedical Engineering Graduate Program, Schulich School of Engineering, University of Calgary, Calgary, AB, Canada
| | - Michael T Kuczynski
- Department of Radiology, Cumming School of Medicine, University of Calgary, 3280 Hospital Dr NW, Calgary, AB, T2N 4Z6, Canada
- McCaig Institute for Bone and Joint Health, Cumming School of Medicine, University of Calgary, Calgary, AB, Canada
- Biomedical Engineering Graduate Program, Schulich School of Engineering, University of Calgary, Calgary, AB, Canada
| | - Daphne A Kaketsis
- Department of Radiology, Cumming School of Medicine, University of Calgary, 3280 Hospital Dr NW, Calgary, AB, T2N 4Z6, Canada
- McCaig Institute for Bone and Joint Health, Cumming School of Medicine, University of Calgary, Calgary, AB, Canada
- Biomedical Engineering Graduate Program, Schulich School of Engineering, University of Calgary, Calgary, AB, Canada
| | - Sarah L Manske
- Department of Radiology, Cumming School of Medicine, University of Calgary, 3280 Hospital Dr NW, Calgary, AB, T2N 4Z6, Canada.
- McCaig Institute for Bone and Joint Health, Cumming School of Medicine, University of Calgary, Calgary, AB, Canada.
- Biomedical Engineering Graduate Program, Schulich School of Engineering, University of Calgary, Calgary, AB, Canada.
| |
Collapse
|
13
|
Hsieh SS, Leng S, Rajendran K, Tao S, McCollough CH. Photon Counting CT: Clinical Applications and Future Developments. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES 2021; 5:441-452. [PMID: 34485784 PMCID: PMC8409241 DOI: 10.1109/trpms.2020.3020212] [Citation(s) in RCA: 56] [Impact Index Per Article: 18.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
The use of a photon counting detector in CT (PCD CT) is currently the subject of intense investigation and development. In this review article, we will describe potential clinical applications of this technology with a particular focus on the experience of our own institution with a prototype PCD CT scanner. PCDs have three primary advantages over conventional, energy integrating detectors (EIDs): they provide spectral information without need for a dedicated dual energy protocol; they are immune to electronic noise; and they can be made very high resolution without significant compromises to quantum efficiency. These advantages translate into several clinical applications. Metal artifacts, beam hardening artifacts, and noise streaks from photon starvation can be better mitigated using PCD CT. Certain incidental findings can be better characterized using the spectral information from PCD CT. High-contrast, high-resolution structures such as the temporal bone can be better visualized using PCD CT and at greatly reduced dose. We also discuss new possibilities on the horizon, including new contrast agents, and how anticipated improvements in PCD CT will translate to performance in these applications.
Collapse
Affiliation(s)
- Scott S Hsieh
- Department of Radiology at the Mayo Clinic, Rochester MN 55905 USA
| | - Shuai Leng
- Department of Radiology at the Mayo Clinic, Rochester MN 55905 USA
| | | | - Shengzhen Tao
- Department of Radiology at the Mayo Clinic, Rochester MN 55905 USA
| | | |
Collapse
|
14
|
Nandra G, Duxbury O, Patel P, Patel JH, Patel N, Vlahos I. Technical and Interpretive Pitfalls in Adrenal Imaging. Radiographics 2021; 40:1041-1060. [PMID: 32609593 DOI: 10.1148/rg.2020190080] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
The adrenal gland may exhibit a wide variety of pathologic conditions. A number of imaging techniques can be used to characterize these, although it is not always possible to attain a definitive diagnosis radiologically. Incorrect diagnoses may be made if radiologists are not attentive to technical parameters and interpretive factors associated with adrenal gland imaging. Hence, an appreciation of the intricacies of adrenal imaging strategies and characterization is required; this can be aided by understanding the pitfalls of adrenal imaging. Technical pitfalls at CT may relate to the imaging parameters, including region of interest characteristics, tube voltage selection, and the timing of contrast material-enhanced imaging. With MRI, imaging acquisition technique and evaluation of the reference tissues used in chemical shift MRI are important considerations that can directly influence image interpretation. Interpretive errors may occur when evaluating adrenal washout at CT without considering other radiologic features, including the size of adrenal nodules, the presence of fat or calcification, the attenuation of nodules, and atypical imaging features. The characterization of an incidental adrenal lesion as benign or malignant does not end the role of the radiologist; consideration as to whether an adrenal lesion is associated with endocrine dysfunction is required. While imaging may not be optimal for establishing endocrine activity, there are imaging features from which radiologists may infer function. In cases of known endocrine activity, imaging can guide clinical management, including further investigations such as venous sampling. ©RSNA, 2020.
Collapse
Affiliation(s)
- Gurinder Nandra
- From the Department of Radiology, St George's Hospital NHS Trust, Blackshaw Road, London SW17 0QT, England
| | - Oliver Duxbury
- From the Department of Radiology, St George's Hospital NHS Trust, Blackshaw Road, London SW17 0QT, England
| | - Pawan Patel
- From the Department of Radiology, St George's Hospital NHS Trust, Blackshaw Road, London SW17 0QT, England
| | - Jaymin H Patel
- From the Department of Radiology, St George's Hospital NHS Trust, Blackshaw Road, London SW17 0QT, England
| | - Nirav Patel
- From the Department of Radiology, St George's Hospital NHS Trust, Blackshaw Road, London SW17 0QT, England
| | - Ioannis Vlahos
- From the Department of Radiology, St George's Hospital NHS Trust, Blackshaw Road, London SW17 0QT, England
| |
Collapse
|
15
|
Hines JJ, Eacobacci K, Goyal R. The Incidental Renal Mass- Update on Characterization and Management. Radiol Clin North Am 2021; 59:631-646. [PMID: 34053610 DOI: 10.1016/j.rcl.2021.03.011] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
Renal masses are commonly encountered on cross-sectional imaging examinations performed for nonrenal indications. Although most can be dismissed as benign cysts, a subset will be either indeterminate or suspicious; in many cases, imaging cannot be used to reliably differentiate between benign and malignant masses. On-going research in defining characteristics of common renal masses on advanced imaging shows promise in offering solutions to this issue. A recent update of the Bosniak classification (used to categorize cystic renal masses) was proposed with the goals of decreasing imaging follow-up in likely benign cystic masses, and therefore avoiding unnecessary surgical resection of such masses.
Collapse
Affiliation(s)
- John J Hines
- Department of Radiology, Huntington Hospital, Northwell Health, 270 Park Avenue, Huntington, NY 11743, USA.
| | - Katherine Eacobacci
- Donald and Barbara Zucker School of Medicine at Hofstra/Northwell, 500 Hofstra Boulevard, Hempstead, NY 11549, USA
| | - Riya Goyal
- Department of Radiology, Donald and Barbara Zucker School of Medicine at Hofstra/Northwell, 500 Hofstra Boulevard, Hempstead, NY 11549, USA
| |
Collapse
|
16
|
Edney E, Davenport MS, Curci N, Schieda N, Krishna S, Hindman N, Silverman SG, Pedrosa I. Bosniak classification of cystic renal masses, version 2019: interpretation pitfalls and recommendations to avoid misclassification. Abdom Radiol (NY) 2021; 46:2699-2711. [PMID: 33484283 DOI: 10.1007/s00261-020-02906-8] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2020] [Revised: 12/01/2020] [Accepted: 12/06/2020] [Indexed: 12/22/2022]
Abstract
The purpose of this review is to describe the potential sources of variability or discrepancy in interpretation of cystic renal masses under the Bosniak v2019 classification system. Strategies to avoid these pitfalls and clinical examples of diagnostic approaches are also presented. Potential pitfalls in the application of Bosniak v2019 are divided into three categories: interpretative, technical, and mass related. An organized, comprehensive review of possible discrepancies in interpreting Bosniak v2019 cystic masses is presented with pictorial examples of difficult clinical cases and proposed solutions. The scheme provided can guide readers to consistent, precise application of the classification system. Radiologists should be aware of the possible sources of misinterpretation of cystic renal masses when applying Bosniak v2019. Knowing which features and types of cystic masses are prone to interpretive errors, in addition to the inherent trade-offs between the CT and MR techniques used to characterize them, can help radiologists avoid these pitfalls.
Collapse
Affiliation(s)
- Elizabeth Edney
- Department of Radiology, University of Nebraska Medical Center, Omaha, NE, USA.
| | - Matthew S Davenport
- Departments of Radiology and Urology, Michigan Medicine, University of Michigan, Ann Arbor, MI, USA
| | - Nicole Curci
- Department of Radiology, Michigan Medicine, University of Michigan, Ann Arbor, MI, USA
| | - Nicola Schieda
- Department of Medical Imaging, The Ottawa Hospital, University of Ottawa, Ottawa, ON, Canada
| | - Satheesh Krishna
- Joint Department of Medical Imaging, University Health Network, Mount Sinai Hospital and Women's College Hospital, University of Toronto, Toronto, ON, Canada
| | - Nicole Hindman
- Department of Radiology, New York University Langone Medical Center, New York, USA
| | - Stuart G Silverman
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, USA
| | - Ivan Pedrosa
- Department of Radiology, University of Texas Southwestern Medical Center, Dallas, TX, USA
| |
Collapse
|
17
|
Scheinfeld MH, Schwartz C, Jain VR, Goldman IA. Non-traumatic hemoperitoneum in the ED setting: causes, characteristics, prevalence and sex differences. Abdom Radiol (NY) 2021; 46:441-448. [PMID: 32766930 DOI: 10.1007/s00261-020-02699-w] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2020] [Revised: 07/20/2020] [Accepted: 07/29/2020] [Indexed: 11/25/2022]
Abstract
PURPOSE Prevalence and sex differences of non-traumatic hemoperitoneum in the Emergency Department has not been studied in the literature. METHODS Following IRB approval, multiple keyword searches were used to identify all cases of hemoperitoneum over a 55-month period. Cases were reviewed to confirm and quantify the hemoperitoneum. Maximum attenuation was used to grade blood density. Medical records were reviewed to determine cause, interventions and outcomes in each patient. RESULTS Of the 171 verified cases of non-traumatic hemoperitoneum, 76% of cases were in women. CT exams in women were positive for hemoperitoneum 0.25% of the time, while 0.13% were positive in men. Regarding size, 25.7% were large, 24.5% were moderate and 49.7% were small. Contrast-enhanced studies had HU values of 103 ± 19 (range 47-146) which were significantly higher than for non-enhanced studies with values of 82 ± 19 (range 43-121, p < 0.001). The most common cause of non-traumatic hemoperitoneum was ruptured ovarian cyst which was found in 58% of women (76 cases). Of these, 69 patients received observation, 6 patients underwent surgery and 1 patient received Vitamin K. For the 95 non-ovarian cyst cases, 65% patients were admitted and then discharged, 22% were discharged from the ED, 12% expired and 1% were transferred to a different hospital. Post-procedure hemorrhage was the second to most common cause in women (24/130 = 18%) and the most common etiology in men (14/41 = 34%). CONCLUSIONS In women, ovarian cyst rupture was the most common etiology of hemoperitoneum. Post-procedure hemorrhage was second in women and the most common etiology in men. Although unusual causes of hemoperitoneum will be encountered, understanding the most common causes of hemoperitoneum can provide a reasonable starting point when attempting to determine the most likely etiology of hemoperitoneum in any individual patient.
Collapse
Affiliation(s)
- Meir H Scheinfeld
- Division of Emergency Radiology, Department of Radiology, Montefiore Medical Center, Albert Einstein College of Medicine, 111 East 210 Street, Bronx, NY, 10467, USA.
| | - Carly Schwartz
- Division of Emergency Radiology, Department of Radiology, Montefiore Medical Center, Albert Einstein College of Medicine, 111 East 210 Street, Bronx, NY, 10467, USA
| | - Vineet R Jain
- Division of Emergency Radiology, Department of Radiology, Montefiore Medical Center, Albert Einstein College of Medicine, 111 East 210 Street, Bronx, NY, 10467, USA
| | - Inessa A Goldman
- Division of Emergency Radiology, Department of Radiology, Montefiore Medical Center, Albert Einstein College of Medicine, 111 East 210 Street, Bronx, NY, 10467, USA
| |
Collapse
|
18
|
Lee HW, Ha HI, Park SY, Lim HK. Reliability of 3D image analysis and influence of contrast medium administration on measurement of Hounsfield unit values of the proximal femur. PLoS One 2020; 15:e0241012. [PMID: 33085702 PMCID: PMC7577441 DOI: 10.1371/journal.pone.0241012] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2020] [Accepted: 10/07/2020] [Indexed: 11/18/2022] Open
Abstract
PURPOSE To evaluate the reliability of 3D image analysis and the effect of an iodine contrast agent on the computed tomography (CT) Hounsfield unit (HU) values of the proximal femur. MATERIALS AND METHODS Fifty female patients (mean age, 61.3 years; age range, 50-79 years) who underwent both pre- and post-enhancement abdominopelvic CT scans were included in this retrospective study. Whole 3D volumes of the left proximal femur from the head to the lesser trochanter were extracted using the regional growth technique with commercial 3D software. Total volume, mean HU, and HU histogram analysis (HUHA) values of the extracted femur were calculated. HUHA distribution was classified into HUHAfat for the assumed fatty marrow (percentage of negative HU values) and HUHAdense-bone (percentage of HU values ≥ 126 HU). Reliability was assessed by calculating intra- and interobserver correlation coefficients (ICCs) and by drawing Bland-Altman plots. The effect of contrast medium administration was evaluated by the paired t-test. RESULTS All intra- and interobserver ICCs of 3D volume measurements showed excellent reproducibility (all ICCs > 0.90). On Bland-Altman analysis of two observers' 3D volume measurements, the differences in the mean total volume, HUHAfat, HUHAdense-bone, and mean HU were 2.4 cm3, 0.17%, 0.6%, and 1.9 HU, respectively. The mean difference in HU after contrast agent administration (-2.2 HU) was not significant (P = 0.27). The mean difference in HUHAfat and HUHAdense-bone after contrast agent administration were -1.1% and -2.2%, respectively, on the Bland-Altman plot. HUHAfat and HUHAdense-bone showed significant differences (P < 0.05). The 95% limits of agreement for HUHAfat, HUHAdense-bone, and mean HU were -3.6% to 1.3%, -6.5% to 2.1%, and -30.0 to 25.5 HU, respectively. CONCLUSION Image analysis based on 3D volume measurement of the proximal femur showed excellent reliability, with the contrast agent administration showing negligible influence on the mean HU.
Collapse
Affiliation(s)
- Hye-Won Lee
- Department of Radiology, Hallym University Sacred Heart Hospital, Anyang-si, Gyeonggi-do, Republic of Korea
| | - Hong Il Ha
- Department of Radiology, Hallym University Sacred Heart Hospital, Anyang-si, Gyeonggi-do, Republic of Korea
- * E-mail:
| | - Sun-Young Park
- Department of Radiology, Hallym University Sacred Heart Hospital, Anyang-si, Gyeonggi-do, Republic of Korea
| | - Hyun Kyung Lim
- Department of Radiology, Soonchunhyang University Seoul Hospital, Seoul, Republic of Korea
| |
Collapse
|
19
|
Clinical Importance of Incidental Homogeneous Renal Masses That Measure 10-40 mm and 21-39 HU at Portal Venous Phase CT: A 12-Institution Retrospective Cohort Study. AJR Am J Roentgenol 2020; 217:135-140. [PMID: 32845714 DOI: 10.2214/ajr.20.24245] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
Abstract
BACKGROUND. Incidental homogeneous renal masses are frequently encountered at portal venous phase CT. The American College of Radiology Incidental Findings Committee's white paper on renal masses recommends additional imaging for incidental homogeneous renal masses greater than 20 HU, but single-center data and the Bosniak classification version 2019 suggest the optimal attenuation threshold for detecting solid masses should be higher. OBJECTIVE. The purpose of this article is to determine the clinical importance of small (10-40 mm) incidentally detected homogeneous renal masses measuring 21-39 HU at portal venous phase CT. METHODS. We performed a 12-institution retrospective cohort study of adult patients who underwent portal venous phase CT for a nonrenal indication. The date of the first CT at each institution ranged from January 1, 2008, to January 1, 2014. Consecutive reports from 12,167 portal venous phase CT examinations were evaluated. Images were reviewed for 4529 CT examinations whose report described a focal renal mass. Eligible masses were 10-40 mm, well-defined, subjectively homogeneous, and 21-39 HU. Of these, masses that were shown to be solid without macroscopic fat; classified as Bosniak IIF, III, or IV; or confirmed to be malignant were considered clinically important. The reference standard was renal mass protocol CT or MRI, ultrasound of definitively benign cysts or solid masses, single-phase contrast-enhanced CT or unenhanced MRI showing no growth or morphologic change for 5 years or more, or clinical follow-up 5 years or greater. A reference standard was available for 346 masses in 300 patients. The 95% CIs were calculated using the binomial exact method. RESULTS. Eligible masses were identified in 4.2% of patients (514/12,167; 95% CI, 3.9-4.6%). Of 346 masses with a reference standard, none were clinically important (0%; 95% CI, 0-0.9%). Mean mass size was 17 mm; 72% (248/346) measured 21-30 HU, and 28% (98/346) measured 31-39 HU. CONCLUSION. Incidental small homogeneous renal masses measuring 21-39 HU at portal venous phase CT are common and highly likely benign. CLINICAL IMPACT. The change in attenuation threshold signifying the need for additional imaging from greater than 20 HU to greater than 30 HU proposed by the Bosniak classification version 2019 is supported.
Collapse
|
20
|
Krishna S, Leckie A, Kielar A, Hartman R, Khandelwal A. Imaging of Renal Cancer. Semin Ultrasound CT MR 2020; 41:152-169. [DOI: 10.1053/j.sult.2019.12.004] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
|
21
|
Does quantitative assessment of arterial phase hyperenhancement and washout improve LI-RADS v2018–based classification of liver lesions? Eur Radiol 2020; 30:2922-2933. [DOI: 10.1007/s00330-019-06596-9] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2019] [Revised: 11/08/2019] [Accepted: 11/18/2019] [Indexed: 12/18/2022]
|
22
|
Hwang EJ, Paek M, Yoon SH, Kim J, Lee HY, Goo JM, Kim H, Kim H, Ackman JB. Quantitative Thoracic Magnetic Resonance Criteria for the Differentiation of Cysts from Solid Masses in the Anterior Mediastinum. Korean J Radiol 2020; 20:854-861. [PMID: 30993936 PMCID: PMC6470082 DOI: 10.3348/kjr.2018.0699] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2018] [Accepted: 01/12/2019] [Indexed: 12/27/2022] Open
Abstract
Objective To evaluate quantitative magnetic resonance imaging (MRI) parameters for differentiation of cysts from and solid masses in the anterior mediastinum. Materials and Methods The development dataset included 18 patients from two institutions with pathologically-proven cysts (n = 6) and solid masses (n = 12) in the anterior mediastinum. We measured the maximum diameter, normalized T1 and T2 signal intensity (nT1 and nT2), normalized apparent diffusion coefficient (nADC), and relative enhancement ratio (RER) of each lesion. RERs were obtained by non-rigid registration and subtraction of precontrast and postcontrast T1-weighted images. Differentiation criteria between cysts and solid masses were identified based on receiver operating characteristics analysis. For validation, two separate datasets were utilized: 15 patients with 8 cysts and 7 solid masses from another institution (validation dataset 1); and 11 patients with clinically diagnosed cysts stable for more than two years (validation dataset 2). Sensitivity and specificity were calculated from the validation datasets. Results nT2, nADC, and RER significantly differed between cysts and solid masses (p = 0.032, 0.013, and < 0.001, respectively). The following criteria differentiated cysts from solid masses: RER < 26.1%; nADC > 0.63; nT2 > 0.39. In validation dataset 1, the sensitivity of the RER, nADC, and nT2 criteria was 87.5%, 100%, and 75.0%, and the specificity was 100%, 40.0%, and 57.4%, respectively. In validation dataset 2, the sensitivity of the RER, nADC, and nT2 criteria was 90.9%, 90.9%, and 72.7%, respectively. Conclusion Quantitative MRI criteria using nT2, nADC, and particularly RER can assist differentiation of cysts from solid masses in the anterior mediastinum.
Collapse
Affiliation(s)
- Eui Jin Hwang
- Department of Radiology, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Korea
| | | | - Soon Ho Yoon
- Department of Radiology, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Korea.
| | - Jihang Kim
- Department of Radiology, Seoul National University Bundang Hospital, Seongnam, Korea
| | - Ho Yun Lee
- Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Jin Mo Goo
- Department of Radiology, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Korea
| | - Hyungjin Kim
- Department of Radiology, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Korea
| | - Heekyung Kim
- Department of Radiology, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Korea
| | - Jeanne B Ackman
- Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
| |
Collapse
|
23
|
Lee SH, Yoon SH, Nam JG, Kim HJ, Ahn SY, Kim HK, Lee HJ, Lee HH, Cheon GJ, Goo JM. Distinguishing between Thymic Epithelial Tumors and Benign Cysts via Computed Tomography. Korean J Radiol 2020; 20:671-682. [PMID: 30887749 PMCID: PMC6424822 DOI: 10.3348/kjr.2018.0400] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2018] [Accepted: 12/06/2018] [Indexed: 12/18/2022] Open
Abstract
Objective To investigate whether computed tomography (CT) and fluorine-18-labeled fluoro-2-deoxy-D-glucose (FDG) positron emission tomography (PET) may be applied to distinguish thymic epithelial tumors (TETs) from benign cysts in the anterior mediastinum. Materials and Methods We included 262 consecutive patients with pathologically proven TETs and benign cysts 5 cm or smaller who underwent preoperative CT scans. In addition to conventional morphological and ancillary CT findings, the relationship between the lesion and the adjacent mediastinal pleura was evaluated qualitatively and quantitatively. Mean lesion attenuation was measured on CT images. The maximum standardized uptake value (SUVmax) was obtained with FDG-PET scans in 40 patients. CT predictors for TETs were identified with multivariate logistic regression analysis. For validation, we assessed the diagnostic accuracy and inter-observer agreement between four radiologists in a size-matched set of 24 cysts and 24 TETs using a receiver operating characteristic curve before and after being informed of the study findings. Results The multivariate analysis showed that post-contrast attenuation of 60 Hounsfield unit or higher (odds ratio [OR], 12.734; 95% confidence interval [CI], 2.506–64.705; p = 0.002) and the presence of protrusion from the mediastinal pleura (OR, 9.855; 95% CI, 1.749–55.535; p = 0.009) were the strongest CT predictors for TETs. SUVmax was significantly higher in TETs than in cysts (5.3 ± 2.4 vs. 1.1 ± 0.3; p < 0.001). After being informed of the study findings, the readers' area under the curve improved from 0.872–0.955 to 0.949–0.999 (p = 0.066–0.149). Inter-observer kappa values for protrusion were 0.630–0.941. Conclusion Post-contrast CT attenuation, protrusion from the mediastinal pleura, and SUVmax were useful imaging features for distinguishing TETs from cysts in the anterior mediastinum.
Collapse
Affiliation(s)
- Sang Hyup Lee
- Department of Radiology, Seoul National University College of Medicine, Seoul, Korea.,Department of Radiology, Seoul National University Hospital, Seoul, Korea
| | - Soon Ho Yoon
- Department of Radiology, Seoul National University College of Medicine, Seoul, Korea.,Department of Radiology, Seoul National University Hospital, Seoul, Korea.
| | - Ju Gang Nam
- Department of Radiology, Seoul National University College of Medicine, Seoul, Korea.,Department of Radiology, Seoul National University Hospital, Seoul, Korea
| | - Hyung Jin Kim
- Department of Radiology, Seoul National University College of Medicine, Seoul, Korea.,Department of Radiology, Seoul National University Hospital, Seoul, Korea
| | - Su Yeon Ahn
- Department of Radiology, Konkuk University School of Medicine, Seoul, Korea.,Department of Radiology, Konkuk University Medical Center, Konkuk University School of Medicine, Seoul, Korea
| | - Hee Kyung Kim
- Department of Radiology, Seoul National University College of Medicine, Seoul, Korea.,Department of Radiology, Seoul National University Hospital, Seoul, Korea
| | - Hyun Ju Lee
- Department of Radiology, Seoul National University College of Medicine, Seoul, Korea.,Department of Radiology, Seoul National University Hospital, Seoul, Korea
| | - Hwan Hee Lee
- Department of Nuclear Medicine, Seoul National University College of Medicine, Seoul National University Hospital, Seoul, Korea
| | - Gi Jeong Cheon
- Department of Nuclear Medicine, Seoul National University College of Medicine, Seoul National University Hospital, Seoul, Korea
| | - Jin Mo Goo
- Department of Radiology, Seoul National University College of Medicine, Seoul, Korea.,Department of Radiology, Seoul National University Hospital, Seoul, Korea.,Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Korea
| |
Collapse
|
24
|
Diagnostic Accuracy of Attenuation Difference and Iodine Concentration Thresholds at Rapid-Kilovoltage-Switching Dual-Energy CT for Detection of Enhancement in Renal Masses. AJR Am J Roentgenol 2019; 213:619-625. [PMID: 31120787 DOI: 10.2214/ajr.18.20990] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
OBJECTIVE. The objective of our study was to evaluate iodine concentration and attenuation change in Hounsfield unit (ΔHU) thresholds to diagnose enhancement in renal masses at rapid-kilovoltage-switching dual-energy CT (DECT). MATERIALS AND METHODS. We evaluated 30 consecutive histologically confirmed solid renal masses (including nine papillary renal cell carcinomas [RCCs]) and 27 benign cysts (17 simple and 10 hemorrhagic or proteinaceous cysts) with DECT December 2016 and May 2018. A blinded radiologist measured iodine concentration (in milligrams per milliliter) and ΔHU (attenuation on enhanced CT - attenuation on unenhanced CT) using 70-keV corticomedullary (CM) phase virtual monochromatic and 120-kVp nephrographic (NG) phase images. The accuracies of previously described enhancement thresholds were compared by ROC curve analysis. RESULTS. An iodine concentration of ≥ 2.0 mg/mL and an iodine concentration of ≥ 1.2 mg/mL achieved sensitivity, specificity, and the area under the ROC curve (AUC) of 73.3%, 100.0%, and 0.87 and 86.7%, 100.0%, and 0.93, respectively. On 70-keV CM phase images, ΔHU ≥ 20 HU and ΔHU ≥ 15 HU yielded sensitivity, specificity, and AUC of 80.0%, 100.0%, and 0.90 and 90.0%, 100.0%, and 0.95, respectively. The numbers of incorrectly classified papillary RCCs were as follows: iodine concentration of ≥ 2.0 mg/mL, 77.8% (7/9; range, 0.7-1.6 mg/mL); iodine concentration of ≥ 1.2 mg/mL, 44.4% (4/9; range, 0.7-0.9 mg/mL); ΔHU ≥ 20 HU on 70-keV CM phase images, 66.7% (6/9; range, 4-17 HU); and ΔHU ≥ 15 HU on 70-keV DECT images, 33.3% (3/9; 4-12 HU). No cyst pseudoenhancement occurred on DECT. For 120-kVp NG phase DECT, ΔHU ≥ 20 HU and ΔHU ≥ 15 HU yielded sensitivity, specificity, and AUC of 93.3%, 96.3%, and 0.95 and 100.0%, 88.9%, and 0.94, respectively. With ΔHU ≥ 20 HU, 22.2% (2/9) (range, 15-18 HU) of papillary RCCs were misclassified and there was one pseudoenhancing cyst. With ΔHU ≥ 15 HU, no papillary RCCs were misclassified but 11.1% (3/27) of cysts showed pseudoenhancement. Only an iodine concentration of ≥ 2.0 mg/mL showed significantly lower accuracy than other measures (p = 0.031-0.045). CONCLUSION. DECT applied in the CM phase performed best using an iodine concentration of ≥ 1.2 mg/mL or a 70-keV ΔHU ≥ 15 HU; these parameters improved sensitivity for the detection of enhancement in renal masses without instances of cyst pseudoenhancement.
Collapse
|
25
|
Diagnostic Accuracy of Dual-Energy CT for Evaluation of Renal Masses: Systematic Review and Meta-Analysis. AJR Am J Roentgenol 2019; 212:W100-W105. [DOI: 10.2214/ajr.18.20527] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
|
26
|
Alrashed A, Ahmad H, Khalili K, Kim TK, Jang HJ, Atri M. Negative Predictive Value of Contrast-Enhanced Ultrasound in Differentiating Avascular Solid-Appearing From Vascularized Masses: A Retrospective Consecutive Study. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2018; 37:2935-2942. [PMID: 29761521 DOI: 10.1002/jum.14659] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/23/2018] [Revised: 03/21/2018] [Accepted: 03/21/2018] [Indexed: 06/08/2023]
Abstract
OBJECTIVES To determine the negative predictive value (NPV) of contrast-enhanced ultrasound (CEUS) to establish the lack of vascularity in a mass. METHODS This work was an Institutional Review Board-approved, Health Insurance Portability and Accountability Act-compliant retrospective study. Acquisition of consent was waived. We included all CEUS examinations performed for tissue characterization between 2004 and 2014 that reported showing no vascularity in a mass. Contrast-enhanced ultrasound findings were considered true-negative when there was stability on imaging for at least 1 year or no evidence of a solid mass, if biopsied, and false-negative if there was lesion growth on imaging within 12 months or an indication of a solid mass on the pathologic examination, if biopsied. One author reviewed all of the reports and follow-up examinations. We conducted a consensus review of all false-negative findings mixed with an equal number of true-negative findings by 2 reviewers, who were blinded to the final results. RESULTS The study population consisted of 97 CEUS examinations in 97 patients, including 48 women and 49 men (mean age ± SD, 65 ± 14 years). Examinations were performed for lesion characterization in the liver (n = 23), pancreas (n = 17), kidney (n = 54), 1 gallbladder, 1 adnexa, and 1 peritoneal lesion. The overall false-negative rate on the official prospective review was 2% (2 of 97). Two false-negative findings were correctly identified on the consensus review. The NPV of CEUS was 97.9% (95 of 97; 95% confidence interval, 93%- 99%) on the official review. CONCLUSIONS Contrast-enhanced ultrasound has a very high NPV to exclude the presence of flow in a mass, and it can be used to exclude the presence of a solid mass.
Collapse
Affiliation(s)
| | - Hassan Ahmad
- Joint Department of Medical Imaging, University of Toronto, Toronto, Ontario, Canada
| | - Korosh Khalili
- Joint Department of Medical Imaging, University of Toronto, Toronto, Ontario, Canada
| | - Tae Kyoung Kim
- Joint Department of Medical Imaging, University of Toronto, Toronto, Ontario, Canada
| | - Huynh-Jung Jang
- Joint Department of Medical Imaging, University of Toronto, Toronto, Ontario, Canada
| | - Mostafa Atri
- Joint Department of Medical Imaging, University of Toronto, Toronto, Ontario, Canada
| |
Collapse
|
27
|
Narayanasamy S, Krishna S, Prasad Shanbhogue AK, Flood TA, Sadoughi N, Sathiadoss P, Schieda N. Contemporary update on imaging of cystic renal masses with histopathological correlation and emphasis on patient management. Clin Radiol 2018; 74:83-94. [PMID: 30314810 DOI: 10.1016/j.crad.2018.09.003] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2018] [Accepted: 09/06/2018] [Indexed: 01/21/2023]
Abstract
This article presents an updated review of cystic renal mass imaging. Most cystic renal masses encountered incidentally are benign and can be diagnosed confidently on imaging and require no follow-up. Hyperattenuating masses discovered at unenhanced or single-phase enhanced computed tomography (CT) measuring between 20-70 HU are indeterminate and can be further investigated first by using ultrasound and, then with multi-phase CT or magnetic resonance imaging (MRI); as the majority represent haemorrhagic/proteinaceous cysts (HPCs). Dual-energy CT may improve differentiation between HPCs and masses by suppressing unwanted pseudo-enhancement observed with conventional CT. HPCs can be diagnosed confidently when measuring >70 HU at unenhanced CT or showing markedly increased signal on T1-weighted imaging. Although the Bosniak criteria remains the reference standard for diagnosis and classification of cystic renal masses, histopathological classification and current management has evolved: multilocular cystic renal cell carcinoma (RCC) has been reclassified as a cystic renal neoplasm of low malignant potential, few Bosniak 2F cystic masses progress radiologically during follow-up; RCC with predominantly cystic components are less aggressive than solid RCC; and Bosniak III cystic masses behave non-aggressively. These advances have led to an increase in non-radical management or surveillance of cystic renal masses including Bosniak 3 lesions. Tubulocystic RCC is a newly described entity with distinct imaging characteristics, resembling a pancreatic serous microcystadenoma. Other benign cystic masses including: mixed epithelial stromal tumours (MEST) are now considered in the spectrum of cystic nephroma and angiomyolipoma (AML) with epithelial cysts (AMLEC) resemble a fat-poor AML with cystic components.
Collapse
Affiliation(s)
- S Narayanasamy
- Department of Medical Imaging, The Ottawa Hospital, University of Ottawa, 501 Smyth Road, Ottawa, ON K1H 8L6, Canada
| | - S Krishna
- Department of Medical Imaging, The Ottawa Hospital, University of Ottawa, 501 Smyth Road, Ottawa, ON K1H 8L6, Canada
| | - A K Prasad Shanbhogue
- Department of Radiology, New York University School of Medicine, 660 First Avenue, New York, NY 10016, USA
| | - T A Flood
- Department of Anatomic Pathology, The Ottawa Hospital, University of Ottawa, 501 Smyth Road, Ottawa, ON K1H 8L6, Canada
| | - N Sadoughi
- Department of Medical Imaging, The Ottawa Hospital, University of Ottawa, 501 Smyth Road, Ottawa, ON K1H 8L6, Canada
| | - P Sathiadoss
- Department of Medical Imaging, The Ottawa Hospital, University of Ottawa, 501 Smyth Road, Ottawa, ON K1H 8L6, Canada
| | - N Schieda
- Department of Medical Imaging, The Ottawa Hospital, University of Ottawa, 501 Smyth Road, Ottawa, ON K1H 8L6, Canada.
| |
Collapse
|
28
|
Attenuation and Degree of Enhancement With Conventional 120-kVp Polychromatic CT and 70-keV Monochromatic Rapid Kilovoltage-Switching Dual-Energy CT in Cystic and Solid Renal Masses. AJR Am J Roentgenol 2018; 211:789-796. [DOI: 10.2214/ajr.17.19226] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
|
29
|
Soesbe TC, Ananthakrishnan L, Lewis MA, Duan X, Nasr K, Xi Y, Abbara S, Leyendecker JR, Lenkinski RE. Pseudoenhancement effects on iodine quantification from dual-energy spectral CT systems: A multi-vendor phantom study regarding renal lesion characterization. Eur J Radiol 2018; 105:125-133. [DOI: 10.1016/j.ejrad.2018.06.002] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2017] [Revised: 04/12/2018] [Accepted: 06/01/2018] [Indexed: 01/30/2023]
|
30
|
Prevalence of Solid Tumors in Incidentally Detected Homogeneous Renal Masses Measuring > 20 HU on Portal Venous Phase CT. AJR Am J Roentgenol 2018; 211:W173-W177. [PMID: 29995501 DOI: 10.2214/ajr.17.19351] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
OBJECTIVE The purpose of this study was to determine the prevalence of solid tumors in incidental homogeneous renal masses with attenuation greater than 20 HU on portal venous phase CT images. MATERIALS AND METHODS In this retrospective study, the records of patients with incidental indeterminate (> 20 HU) homogeneous renal masses on portal venous phase CT scans from September 11, 2007, through March 18, 2017, were identified. Adult patients were included if they had undergone follow-up ultrasound, contrast-enhanced MRI, multiphase contrast-enhanced CT, or pathologic analysis alone to confirm the solid or cystic nature of the lesion. A single ROI was placed in the center of the mass, and lesions were characterized as ≥ 50% exophytic, < 50% exophytic, or entirely surrounded by renal parenchyma. RESULTS There were 322 masses in 267 patients. The mean lesion size was 16.6 (SD, 9.8) mm (range, 9-45 mm). Lesions were ≥ 50% exophytic in 92 cases, < 50% exophytic in 111 cases, and completely surrounded by renal parenchyma in 119 cases. All nonsolid lesions were characterized as benign cysts. The numbers of solid lesions per total number of lesions in each attenuation group were: 20-30 HU (0/140), 30-40 HU (0/67), 40-50 HU (1/38), 50-60 HU (3/24), 60-70 HU (5/17), 70-80 HU (5/17), and > 80 HU (8/19). All 207 lesions in the 20- to 40-HU range were benign cysts with no solid lesions (0%; 95% CI, 0.0-1.4%). CONCLUSION Small homogeneous renal masses measuring 20-40 HU on portal venous phase CT images are highly likely to be benign cysts.
Collapse
|
31
|
Abstract
The increase in serendipitous detection of solid renal masses on imaging has not resulted in a reduction in mortality from renal cell carcinoma. Consequently, efforts for improved lesion characterization have been pursued and incorporated into management algorithms for distinguishing clinically significant tumors from those with favorable histology or benign conditions. Although diagnostic imaging strategies have evolved for optimized lesion detection, distinction between benign tumors and both indolent and aggressive malignant neoplasms remain an important diagnostic challenge. Recent advances in cross-sectional imaging have expanded the role of these tests in the noninvasive characterization of solid renal tumors.
Collapse
Affiliation(s)
- Fernando U Kay
- Department of Radiology; UT Southwestern Medical Center, 2201 Inwood Road, Suite 210, Dallas, TX 75390, USA
| | - Ivan Pedrosa
- Department of Radiology; UT Southwestern Medical Center, 2201 Inwood Road, Suite 210, Dallas, TX 75390, USA.
| |
Collapse
|
32
|
Hélénon O, Crosnier A, Verkarre V, Merran S, Méjean A, Correas JM. Simple and complex renal cysts in adults: Classification system for renal cystic masses. Diagn Interv Imaging 2018; 99:189-218. [DOI: 10.1016/j.diii.2017.10.005] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2017] [Accepted: 09/26/2017] [Indexed: 02/08/2023]
|
33
|
Hu EM, Ellis JH, Silverman SG, Cohan RH, Caoili EM, Davenport MS. Expanding the Definition of a Benign Renal Cyst on Contrast-enhanced CT: Can Incidental Homogeneous Renal Masses Measuring 21-39 HU be Safely Ignored? Acad Radiol 2018; 25:209-212. [PMID: 29174191 DOI: 10.1016/j.acra.2017.09.021] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2017] [Revised: 09/27/2017] [Accepted: 09/27/2017] [Indexed: 11/30/2022]
Abstract
RATIONALE AND OBJECTIVE We aimed to determine the frequency and clinical significance of homogeneous renal masses measuring 21-39 Hounsfield units on contrast-enhanced computed tomography (CT). METHODS Subjects 40-69 years old undergoing portal-venous-phase contrast-enhanced abdominal CT from January 1, 2006 to December 31, 2010 with slice thickness ≤5 mm and no prior CT or magnetic resonance imaging were identified (n = 1387) for this institutional review board-approved retrospective cohort study. Images were manually reviewed by three radiologists in consensus to identify all circumscribed homogeneous renal masses (maximum of three per subject) ≥10 mm with a measured attenuation of 21-39 Hounsfield units. Exclusion criteria were known renal cancer or imaging performed for a renal indication. The primary outcome was retrospective characterization as a clinically significant mass, defined as a solid mass, a Bosniak IIF/III/IV mass, or extirpative therapy or metastatic renal cancer within 5 years' follow-up. RESULTS Eligible masses (n = 74) were found in 5% (63/1387) of subjects. Of those with a reference standard (n = 42), none (0% [95% CI: 0.0%-8.4%]) were determined to be clinically significant. CONCLUSION Incidental renal masses on contrast-enhanced CT that are homogeneous and display an attenuation of 21-39 Hounsfield units are uncommon in patients 40-69 years of age, unlikely to be clinically significant, and may not need further imaging evaluation. If these results can be replicated in an independent and larger population, the practical definition of a benign cyst on imaging may be able to be expanded.
Collapse
Affiliation(s)
- Eric M Hu
- Department of Radiology, University of Michigan Health System, 1500 E. Medical Center Dr B2-A209P, Ann Arbor, MI 48109; Michigan Radiology Quality Collaborative, Ann Arbor, Michigan
| | - James H Ellis
- Department of Radiology, University of Michigan Health System, 1500 E. Medical Center Dr B2-A209P, Ann Arbor, MI 48109; Department of Urology, University of Michigan Health System, Ann Arbor, Michigan
| | | | - Richard H Cohan
- Department of Radiology, University of Michigan Health System, 1500 E. Medical Center Dr B2-A209P, Ann Arbor, MI 48109
| | - Elaine M Caoili
- Department of Radiology, University of Michigan Health System, 1500 E. Medical Center Dr B2-A209P, Ann Arbor, MI 48109
| | - Matthew S Davenport
- Department of Radiology, University of Michigan Health System, 1500 E. Medical Center Dr B2-A209P, Ann Arbor, MI 48109; Michigan Radiology Quality Collaborative, Ann Arbor, Michigan; Department of Urology, University of Michigan Health System, Ann Arbor, Michigan.
| |
Collapse
|
34
|
Magnetic resonance imaging as an adjunct diagnostic tool in computed tomography defined Bosniak IIF-III renal cysts: a multicenter study. World J Urol 2018; 36:905-911. [PMID: 29383479 DOI: 10.1007/s00345-018-2176-z] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2017] [Accepted: 01/03/2018] [Indexed: 12/26/2022] Open
Abstract
INTRODUCTION CT imaging is the standard examination for renal cystic lesions and defines the Bosniak category, which dictates further management. Given that Bosniak II/IIF/III renal cystic lesions can potentially harbor renal cell carcinoma (RCC), additional diagnostic modalities may be required in management decision making. AIM To determine the value of additional magnetic resonance imaging in CT-defined Bosniak IIF-III renal cystic lesions. MATERIALS AND METHODS This a multicenter retrospective study of 46 consecutive patients, diagnosed with cystic renal lesions between 2009 and 2016. The inclusion criteria were: (1) cystic renal lesion classified as Bosniak IIF-III on CT, (2) a subsequent MRI examination, and (3) documented outcome via surgery for cystic renal mass or follow-up. RESULTS 46 patients (35 males, 11 females) were included. The mean size of the cystic lesion was 3.92 cm (0.7-10 cm). According to the CT findings, Bosniak IIF and III were found in 12 (26.1%) and 34 (73.9%) cases. Reclassification of Bosniak category was done after MRI examination in 31 cases (67.4%). An upgrade rate of 58.7% (27 cases) to a higher category was made, while the downgrade rate to a lower category was achieved in 4 cases (8.7%). As a result, significant therapeutic management change was made in 12/31 patients (38.7%), of whom 8 underwent subsequent surgery. CONCLUSION MRI study may reduce the use of Bosniak IIF category (in comparison with CT), which has a direct impact on therapeutic management (surgery vs. surveillance) in a significant proportion of patients.
Collapse
|
35
|
Abstract
Renal cell carcinoma (RCC) exhibits a diverse and heterogeneous disease spectrum, but insight into its molecular biology has provided an improved understanding of potential risk factors, oncologic behavior, and imaging features. Computed tomography (CT) and MR imaging may allow the identification and preoperative subtyping of RCC and assessment of a response to various therapies. Active surveillance is a viable management option in some patients and has provided further insight into the natural history of RCC, including the favorable prognosis of cystic neoplasms. This article reviews CT and MR imaging in RCC and the role of screening in selected high-risk populations.
Collapse
Affiliation(s)
- Alberto Diaz de Leon
- Department of Radiology, University of Texas Southwestern Medical Center, 2201 Inwood Road, 2nd Floor, Suite 202, Dallas, TX 75390-9085, USA
| | - Ivan Pedrosa
- Department of Radiology, University of Texas Southwestern Medical Center, 2201 Inwood Road, 2nd Floor, Suite 202, Dallas, TX 75390-9085, USA.
| |
Collapse
|
36
|
Is Ultrasound Useful for Further Evaluation of Homogeneously Hyperattenuating Renal Lesions Detected on CT? AJR Am J Roentgenol 2017; 209:604-610. [DOI: 10.2214/ajr.17.17814] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
|
37
|
Sugisawa K, Ichikawa K, Minamishima K, Hasegawa M, Yamada Y, Jinzaki M. Evaluation of the CT Parameters to Suppress Renal Cysts Pseudoenhancement Effect: Influence of the Virtual Monochromatic Spectral Images, the Model-based Iterative Reconstruction Algorithm and the Aperture Size in Phantom Model. Nihon Hoshasen Gijutsu Gakkai Zasshi 2017; 73:636-645. [PMID: 28824087 DOI: 10.6009/jjrt.2017_jsrt_73.8.636] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
PURPOSE The purpose of this study was to evaluate the effect of the virtual monochromatic spectral images (VMSI) and the model-based iterative reconstruction (MBIR) images, to evaluate the influence of the aperture size (40- and 20-mm beam) on renal pseudoenhancement (PE) compared with the filtered back projection (FBP) images. METHODS The renal compartment-CT phantom was filled with iodinated contrast material diluted to the attenuation of 180 Hounsfield units (HU) at 120 kV. The water-filled spherical structures, which simulate cyst, were inserted into the renal compartment. Those diameters were 7, 15 and 25 mm. These were scanned by conventional mode (helical scan, 120 kV-FBP) and dual energy mode. 70 keV-VMSI were reconstructed from the dual energy mode, and MBIR images were reconstructed from conventional mode at 40- and 20-mm aperture. Additionally, the phantom was scanned using non-helical mode with 20-mm aperture, and FBP images were reconstructed. The CT value of the PE for cyst areas was measured for these images. RESULTS The CT values of the cysts were 20.0-14.3 HU on the FBP images, 12.8-12.7 HU on the 70 keV-VMSI (PE-inhibition ratio was 36.0-11.2%) and 16.2-14.0 HU on the MBIR images (19.0-2.1%), respectively, at 40-mm aperture. The PE-inhibition ratio scanned by 20-mm aperture was improved by 28.0% with FBP, 32.8% with 70 keV-VMSI and 29.6% with MBIR compared with 40-mm aperture. One of the FBP images with non-helical mode was 11.6 HU. CONCLUSIONS The best CT technique to minimize PE was the combination of 70 keV-VMSI and 20-mm aperture.
Collapse
Affiliation(s)
- Koichi Sugisawa
- Graduate School of Medical Science, Kanazawa University.,Department of Radiological Technology, Keio University Hospital
| | - Katsuhiro Ichikawa
- Institute of Medical, Pharmaceutical and Health Sciences, Kanazawa University
| | | | | | - Yoshitake Yamada
- Department of Diagnostic Radiology, Keio University School of Medicine
| | - Masahiro Jinzaki
- Department of Diagnostic Radiology, Keio University School of Medicine
| |
Collapse
|
38
|
Krishna S, Murray CA, McInnes MD, Chatelain R, Siddaiah M, Al-Dandan O, Narayanasamy S, Schieda N. CT imaging of solid renal masses: pitfalls and solutions. Clin Radiol 2017; 72:708-721. [PMID: 28592361 DOI: 10.1016/j.crad.2017.05.003] [Citation(s) in RCA: 58] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2016] [Revised: 04/20/2017] [Accepted: 05/02/2017] [Indexed: 12/22/2022]
Abstract
Computed tomography (CT) remains the first-line imaging test for the characterisation of renal masses; however, CT has inherent limitations, which if unrecognised, may result in errors. The purpose of this manuscript is to present 10 pitfalls in the CT evaluation of solid renal masses. Thin section non-contrast enhanced CT (NECT) is required to confirm the presence of macroscopic fat and diagnosis of angiomyolipoma (AML). Renal cell carcinoma (RCC) can mimic renal cysts at NECT when measuring <20 HU, but are usually heterogeneous with irregular margins. Haemorrhagic cysts (HC) may simulate solid lesions at NECT; however, a homogeneous lesion measuring >70 HU is essentially diagnostic of HC. Homogeneous lesions measuring 20-70 HU at NECT or >20 HU at contrast-enhanced (CE) CT, are indeterminate, requiring further evaluation. Dual-energy CT (DECT) can accurately characterise these lesions at baseline through virtual NECT, iodine overlay images, or quantitative iodine concentration analysis without recalling the patient. A minority of hypo-enhancing renal masses (most commonly papillary RCC) show indeterminate or absent enhancement at multiphase CT. Follow-up, CE ultrasound or magnetic resonance imaging (MRI) is required to further characterise these lesions. Small (<3 cm) endophytic cysts commonly show pseudo-enhancement, which may simulate RCC; this can be overcome with DECT or MRI. In small (<4 cm) solid renal masses, 20% of lesions are benign, chiefly AML without visible fat or oncocytoma. Low-dose techniques may simulate lesion heterogeneity due to increased image noise, which can be ameliorated through the appropriate use of iterative reconstruction algorithms.
Collapse
Affiliation(s)
- S Krishna
- Department of Medical Imaging, The Ottawa Hospital, University of Ottawa, Ottawa, Canada
| | - C A Murray
- Department of Medical Imaging, The Ottawa Hospital, University of Ottawa, Ottawa, Canada
| | - M D McInnes
- Department of Medical Imaging, The Ottawa Hospital, University of Ottawa, Ottawa, Canada
| | - R Chatelain
- Department of Medical Imaging, The Ottawa Hospital, University of Ottawa, Ottawa, Canada
| | - M Siddaiah
- Department of Medical Imaging, The Ottawa Hospital, University of Ottawa, Ottawa, Canada
| | - O Al-Dandan
- Department of Radiology, University of Dammam, Dammam, Saudi Arabia
| | - S Narayanasamy
- Department of Medical Imaging, The Ottawa Hospital, University of Ottawa, Ottawa, Canada
| | - N Schieda
- Department of Medical Imaging, The Ottawa Hospital, University of Ottawa, Ottawa, Canada.
| |
Collapse
|
39
|
Differentiating Renal Neoplasms From Simple Cysts on Contrast-Enhanced CT on the Basis of Attenuation and Homogeneity. AJR Am J Roentgenol 2017; 208:801-804. [DOI: 10.2214/ajr.16.17119] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
40
|
Li Q, Liang Y, Huang Q, Zong M, Berman B, Gavrielides MA, Schwartz LH, Zhao B, Petrick N. Volumetry of low-contrast liver lesions with CT: Investigation of estimation uncertainties in a phantom study. Med Phys 2017; 43:6608. [PMID: 27908157 DOI: 10.1118/1.4967776] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE To evaluate the performance of lesion volumetry in hepatic CT as a function of various imaging acquisition parameters. METHODS An anthropomorphic abdominal phantom with removable liver inserts was designed for this study. Two liver inserts, each containing 19 synthetic lesions with varying diameter (6-40 mm), shape, contrast (10-65 HU), and both homogenous and mixed-density were designed to have background and lesion CT values corresponding to arterial and portal-venous phase imaging, respectively. The two phantoms were scanned using two commercial CT scanners (GE 750 HD and Siemens Biograph mCT) across a set of imaging protocols (four slice thicknesses, three effective mAs, two convolution kernels, two pitches). Two repeated scans were collected for each imaging protocol. All scans were analyzed using a matched-filter estimator for volume estimation, resulting in 6080 volume measurements across all of the synthetic lesions in the two liver phantoms. A subset of portal venous phase scans was also analyzed using a semi-automatic segmentation algorithm, resulting in about 900 additional volume measurements. Lesions associated with large measurement error (quantified by root mean square error) for most imaging protocols were considered not measurable by the volume estimation tools and excluded for the statistical analyses. Imaging protocols were grouped into distinct imaging conditions based on ANOVA analysis of factors for repeatability testing. Statistical analyses, including overall linearity analysis, grouped bias analysis with standard deviation evaluation, and repeatability analysis, were performed to assess the accuracy and precision of the liver lesion volume biomarker. RESULTS Lesions with lower contrast and size ≤10 mm were associated with higher measurement error and were excluded from further analysis. Lesion size, contrast, imaging slice thickness, dose, and scanner were found to be factors substantially influencing volume estimation. Twenty-four distinct repeatable imaging conditions were determined as protocols for each scanner with a fixed slice thickness and dose. For the matched-filter estimation approach, strong linearity was observed for all imaging data for lesions ≥20 mm. For the Siemens scanner with 50 mAs effective dose at 0.6 mm slice thickness, grouped bias was about -10%. For all other repeatable imaging conditions with both scanners, grouped biases were low (-3%-3%). There was a trend of increasing standard deviation with decreasing dose. For each fixed dose, the standard deviations were similar among the three larger slice thicknesses (1.25, 2.5, 5 mm for GE, 1.5, 3, 5 mm for Siemens). Repeatability coefficients ranged from about 8% to 75% and showed similar trend to grouped standard deviation. For the segmentation approach, the results led to similar conclusions for both lesion characteristic factors and imaging factors but with increasing magnitude in all the error metrics assessed. CONCLUSIONS Results showed that liver lesion volumetry was strongly dependent on lesion size, contrast, acquisition dose, and their interactions. The overall performances were similar for images reconstructed with larger slice thicknesses, clinically used pitches, kernels, and doses. Conditions that yielded repeatable measurements were identified and they agreed with the Quantitative Imaging Biomarker Alliance's (QIBA) profile requirements in general. The authors' findings also suggest potential refinements to these guidelines for the tumor volume biomarker, especially for soft-tissue lesions.
Collapse
Affiliation(s)
- Qin Li
- Division of Imaging, Diagnostics and Software Reliability, Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, US Food and Drug Administration, Silver Spring, Maryland 20993
| | - Yongguang Liang
- Department of Radiology, Columbia University Medical Center, New York, New York 10032
| | - Qiao Huang
- Department of Radiology, Columbia University Medical Center, New York, New York 10032
| | - Min Zong
- Department of Radiology, Columbia University Medical Center, New York, New York 10032
| | - Benjamin Berman
- Division of Imaging, Diagnostics and Software Reliability, Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, US Food and Drug Administration, Silver Spring, Maryland 20993
| | - Marios A Gavrielides
- Division of Imaging, Diagnostics and Software Reliability, Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, US Food and Drug Administration, Silver Spring, Maryland 20993
| | - Lawrence H Schwartz
- Department of Radiology, Columbia University Medical Center, New York, New York 10032
| | - Binsheng Zhao
- Department of Radiology, Columbia University Medical Center, New York, New York 10032
| | - Nicholas Petrick
- Division of Imaging, Diagnostics and Software Reliability, Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, US Food and Drug Administration, Silver Spring, Maryland 20993
| |
Collapse
|
41
|
Abstract
Detection of solid renal masses has increased, although it has not resulted in significant mortality reduction from renal cell carcinoma. Efforts for improved lesion characterization have been pursued and incorporated in management algorithms, in order to distinguish clinically significant tumors from favorable or benign conditions. Concurrently, imaging methods have produced evidence supporting their role as useful tools not only in lesion detection but also characterization. In addition, newer modalities, such as contrast-enhanced ultrasonography, and advanced applications of MR imaging, are being investigated. This article reviews the current role of different imaging methods in the characterization of solid renal masses.
Collapse
Affiliation(s)
- Fernando U Kay
- Department of Radiology, UT Southwestern Medical Center, Harry Hines 5323, 2201 Inwood Road, Dallas, TX 75390, USA
| | - Ivan Pedrosa
- Department of Radiology and Advanced Imaging Research Center, UT Southwestern Medical Center, Harry Hines 5323, 2201 Inwood Road, Dallas, TX 75390, USA.
| |
Collapse
|
42
|
Kawai T, Ozawa Y, Ogawa M, Ohashi K, Suzuki K, Shibamoto Y. Quality Improvement of Dual-Energy Lung Perfusion Image by Reduction of Low-Energy X-Ray Spectrum: An Evaluation on Clinical Images. Pol J Radiol 2016; 81:593-597. [PMID: 27994698 PMCID: PMC5154711 DOI: 10.12659/pjr.899502] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2016] [Accepted: 06/06/2016] [Indexed: 11/09/2022] Open
Abstract
Background The effects of the reduction of low-energy X-ray spectrum on lung perfusion images created by dual-energy CT have not been well evaluated. The aim of this study is to investigate the reliability of lung perfusion blood volume (PBV) images created by dual-energy CT (DECT) equipped with or without a tin filter, focusing on its accuracy adjacent to high-attenuation areas. Material/Methods Among 176 patients who underwent DECT for suspicion of pulmonary embolism, 38 patients (mean age, 64; range, 16 to 83 years) without apparent evidence of pulmonary embolism were evaluated in this study. They underwent DECT at 100/140 kVp with a tin filter on 140 kVp tube (Group A; n=18) or at 80/140 kVp without the filter (Group B; n=20). On the lung PBV images, the degrees of artifacts – pulmonary enhancement defect (PED) and pseudo-enhancement in the trachea (PTE) adjacent to the vena cava were evaluated using a four-point scale (0=minimal to 3=prominent). Results The mean degrees of artifact in Group A were significantly lower than those in Group B (0.8 vs. 1.9; P<0.0001 for PED, respectively, and 1.1 vs. 2.2; P<0.0001 for TPE, respectively). The mean CTDIvols were 4.90±1.14 and 12.98±3.15 mGy (P<0.0001) for Group A and Group B, respectively. Conclusions The quality and accuracy of dual-energy lung perfusion image will be improved by using the tin filter technique.
Collapse
Affiliation(s)
- Tatsuya Kawai
- Department of Radiology, Nagoya City University, Nagoya, Japan
| | - Yoshiyuki Ozawa
- Department of Radiology, Nagoya City University, Nagoya, Japan
| | - Masaki Ogawa
- Department of Radiology, Nagoya City University, Nagoya, Japan
| | - Kazuya Ohashi
- Central Division of Radiology, Nagoya City University Hospital, Nagoya, Japan
| | - Kazushi Suzuki
- Department of Radiology, Nagoya City University, Nagoya, Japan
| | - Yuta Shibamoto
- Department of Radiology, Nagoya City University, Nagoya, Japan
| |
Collapse
|
43
|
Hélénon O, Delavaud C, Dbjay J, Gregory J, Rasouli N, Correas JM. A Practical Approach to Indeterminate and Cystic Renal Masses. Semin Ultrasound CT MR 2016; 38:10-27. [PMID: 28237276 DOI: 10.1053/j.sult.2016.09.002] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
Cystic renal masses are a common entity with a wide differential diagnosis encountered by the radiologist in daily practice. Their characterization relies on the Bosniak classification system that has been widely accepted by radiologists and urologists as a pertinent diagnostic and communication tool. It has been designed to separate cystic lesions requiring surgery (categories III and IV) from those that can be ignored and left alone (categories I and II) or followed (category IIF). Utilization of the Bosniak classification requires, first, previous identification of the cystic nature of a renal mass with the exception of very small lesions.
Collapse
Affiliation(s)
- Olivier Hélénon
- Paris Descartes Medical School, Paris Descartes University, Paris, France; Department of Adult Radiology, Necker Hospital, Paris, France.
| | - Christophe Delavaud
- Paris Descartes Medical School, Paris Descartes University, Paris, France; Department of Adult Radiology, Necker Hospital, Paris, France
| | - Jonathan Dbjay
- Paris Descartes Medical School, Paris Descartes University, Paris, France; Department of Adult Radiology, Necker Hospital, Paris, France
| | - Jules Gregory
- Paris Descartes Medical School, Paris Descartes University, Paris, France; Department of Adult Radiology, Necker Hospital, Paris, France
| | | | - Jean-Michel Correas
- Paris Descartes Medical School, Paris Descartes University, Paris, France; Department of Adult Radiology, Necker Hospital, Paris, France
| |
Collapse
|
44
|
Elstob A, Gonsalves M, Patel U. Diagnostic modalities. Int J Surg 2016; 36:504-512. [PMID: 27321380 DOI: 10.1016/j.ijsu.2016.06.005] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2016] [Revised: 05/23/2016] [Accepted: 06/04/2016] [Indexed: 01/17/2023]
Abstract
The incidental detection of small renal masses on imaging undertaken to evaluate unrelated symptoms or conditions is an increasingly common occurrence. Accurate imaging characterisation is fundamental to determining optimum patient management. The goals of imaging small renal masses include determining whether a lesion is solid or cystic, if there are signs of biological aggressiveness and whether the lesion is likely benign or malignant. The current imaging practices and the evidence supporting the use of different imaging modalities for the characterisation of small renal masses are discussed. CT remains the primary imaging modality and is able to classify most masses into surgical or non-surgical lesions. MRI and contrast enhanced ultrasound are most often employed to problem solve in lesions deemed indeterminate on contrast enhanced CT or for patients in which CECT is contraindicated. Percutaneous biopsy should be considered in lesions that remain indeterminate after initial imaging investigations. Given the central role of imaging in the management of small renal masses, all multidisciplinary team members involved in renal cancer care should have an understanding of the performance of the different imaging modalities.
Collapse
Affiliation(s)
- Alison Elstob
- Radiology Department, St George's University Hospitals NHS Foundation Trust, Blackshaw Road, London, SW17 0QT, UK.
| | - Michael Gonsalves
- Radiology Department, St George's University Hospitals NHS Foundation Trust, Blackshaw Road, London, SW17 0QT, UK
| | - Uday Patel
- Radiology Department, St George's University Hospitals NHS Foundation Trust, Blackshaw Road, London, SW17 0QT, UK
| |
Collapse
|
45
|
Abstract
OBJECTIVE The objective of our study was to determine whether small (< 4 cm) solid renal cell carcinomas (RCCs) enhance on CT below the published enhancement thresholds. MATERIALS AND METHODS For this retrospective study, we reviewed CT examinations of patients with pathologically characterized small solid renal masses. Patients with lipid-rich angiomyolipomas were excluded. The study included consecutive patients who had pathologically characterized small (< 4 cm) renal masses and had undergone CT during the un-enhanced phase and nephrographic phase (NP). Most CT examinations also included imaging during the corticomedullary phase (CMP); four patients did not have CMP images. The CT examinations were performed on a 64-MDCT scanner. Similar-sized ROIs were placed on each lesion on unenhanced and enhanced images and enhancement (in Hounsfield units) was calculated. Masses were considered solid with a threshold enhancement greater than either 15 or 20 HU. RESULTS There were 137 masses in 137 patients, 90 men and 47 women (age range, 21-91 years; median age, 65 years). The renal masses were 1.0-3.9 cm (median, 2.4 cm). Of the 137 masses, 117 (85.4%) were malignant and 20 (14.6%) were benign. One malignant mass and three benign masses did not have CMP images. Twenty of the 116 (17.2%) renal cell carcinomas (RCCs) did not reach the 15-HU threshold enhancement on CMP images, nine of 117 masses (7.7%) did not reach the 15-HU enhancement threshold on NP images, and four of 117 masses (3.4%) did not reach the 15-HU enhancement threshold on both CMP and NP images. The numbers of masses that did not reach the 20-HU enhancement threshold were 24 of 116 masses (20.7%) on CMP images, 14 of 117 masses (11.9%) on NP images, and 11 of 117 masses (9.4%) on both CMP and NP images. Depending on the phase or enhancement threshold, 13.6-59.1% of papillary RCCs did not reach the enhancement threshold. CONCLUSION A minority of small RCCs do not reach either a 15- or 20-HU enhancement threshold and might be misinterpreted as a hyperattenuating cyst. Most RCCs below these enhancement thresholds are papillary RCC.
Collapse
|
46
|
Threshold for Enhancement in Treated Hepatocellular Carcinoma on MDCT: Effect on Necrosis Quantification. AJR Am J Roentgenol 2016; 206:536-43. [PMID: 26901009 DOI: 10.2214/ajr.15.15339] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
OBJECTIVE The objective of our study was to determine whether the conventionally used enhancement threshold of 10 HU for assessing tumor viability in treated hepatocellular carcinoma (HCC) lesions is valid. MATERIALS AND METHODS To distinguish pseudoenhancement from enhancement in a tumor, we used an in vivo model: The attenuation of 54 hepatic cysts during the unenhanced and portal venous phases of MDCT, similar to what may be observed in HCC with central necrosis, was used to determine the threshold for pseudoenhancement. To validate this model, we compared the attenuation value of liver parenchyma in this cohort with that of 22 HCCs during the late arterial phase of enhancement. We tested the effect of this pseudoenhancement on quantifying necrosis in HCC compared with the conventionally used threshold of 10 HU. RESULTS Values of enhancing HCC tissue on arterial phase MDCT (mean, 121.3 HU) were comparable with normal liver parenchyma on venous phase MDCT (117.3 HU) (p = 0.27). The threshold of 17.1 HU was the best threshold for the detection of pseudoenhancement in cysts (99% accuracy, 100% sensitivity, and 98% specificity). When this threshold was used instead of the conventional threshold of 10 HU, the mean necrosis proportion of treated HCC increased from 34.0% to 42.6% and the mean viable tumor proportion decreased from 66.0% to 57.4%. The quantification of viable HCC tissue based on 10 HU and the quantification of viable HCC tissue based on 17.1 HU were found to be significantly different (p < 0.0001). CONCLUSION The threshold of 17.1 HU may be the appropriate cutoff for nonenhancement in a necrotic HCC. Use of this threshold may potentially affect how response to therapy is quantified and categorized.
Collapse
|
47
|
Solid Renal Cell Carcinomas With an Attenuation Similar to That of Water on Unenhanced CT. AJR Am J Roentgenol 2016; 206:W92. [PMID: 27043418 DOI: 10.2214/ajr.15.15968] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
48
|
Computed Tomography Number Measurement Consistency Under Different Beam Hardening Conditions: Comparison Between Dual-Energy Spectral Computed Tomography and Conventional Computed Tomography Imaging in Phantom Experiment. J Comput Assist Tomogr 2016. [PMID: 26196347 PMCID: PMC4654266 DOI: 10.1097/rct.0000000000000287] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/03/2022]
Abstract
To compare computed tomography (CT) number measurement consistency under different beam hardening conditions in phantom experiment between dual-energy spectral CT and conventional CT imaging.
Collapse
|
49
|
Effect of Model-Based Iterative Reconstruction on CT Number Measurements Within Small (10–29 mm) Low-Attenuation Renal Masses. AJR Am J Roentgenol 2015; 205:85-9. [DOI: 10.2214/ajr.14.13835] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
|
50
|
Renal Masses With Equivocal Enhancement at CT: Characterization With Contrast-Enhanced Ultrasound. AJR Am J Roentgenol 2015; 204:W557-65. [PMID: 25905962 DOI: 10.2214/ajr.14.13375] [Citation(s) in RCA: 54] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
OBJECTIVE The purpose of this article is to retrospectively investigate in two radiology centers the role of contrast-enhanced ultrasound in the characterization of renal masses with equivocal enhancement at CT (i.e., with a density increase of 10-20 HU between unenhanced and contrast-enhanced scans) not characterized with conventional ultrasound modes. MATERIALS AND METHODS Forty-seven renal lesions (range, 0.8-7.7 cm; average, 2.6 cm) with equivocal enhancement at CT underwent contrast-enhanced ultrasound using sulfur hexafluoride-filled microbubbles. Examinations were digitally recorded for retrospective blinded evaluation by two radiologists with 20 and 10 years' experience in urologic imaging. Histologic results were available for 30 of 47 (64%) lesions (25 primary malignant tumors, two metastases, and three primary benign lesions). Two lesions increased in size and complexity during the follow-up and were considered malignant. One Bosniak category III and 14 category IIF cysts were stable after a follow-up of at least 3 years and were considered benign. ROC curve analysis was used to assess the capability of contrast-enhanced ultrasound to differentiate benign from malignant lesions. RESULTS Twelve likely complex cystic lesions at gray-scale ultrasound were cystic also on contrast-enhanced ultrasound and reference procedures. Eleven of 34 lesions that appeared solid at gray-scale ultrasound were cystic on contrast-enhanced ultrasound and reference procedures. One lesion considered likely solid by one radiologist and possibly cystic by the other was a solid tumor at contrast-enhanced ultrasound and histologic analysis. The diagnostic performance of contrast-enhanced ultrasound to characterize the lesions as benign or malignant was high for both readers (AUC, 0.958 and 0.966, respectively). CONCLUSION Contrast-enhanced ultrasound is effective for characterizing renal lesions presenting with equivocal enhancement at CT.
Collapse
|