51
|
Vickerman V, Kim C, Kamm RD. Microfluidic Devices for Angiogenesis. MECHANICAL AND CHEMICAL SIGNALING IN ANGIOGENESIS 2013. [DOI: 10.1007/978-3-642-30856-7_5] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
|
52
|
Funamoto K, Zervantonakis IK, Liu Y, Ochs CJ, Kim C, Kamm RD. A novel microfluidic platform for high-resolution imaging of a three-dimensional cell culture under a controlled hypoxic environment. LAB ON A CHIP 2012; 12:4855-63. [PMID: 23023115 PMCID: PMC4086303 DOI: 10.1039/c2lc40306d] [Citation(s) in RCA: 108] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/18/2023]
Abstract
Low oxygen tensions experienced in various pathological and physiological conditions are a major stimulus for angiogenesis. Hypoxic conditions play a critical role in regulating cellular behaviour including migration, proliferation and differentiation. This study introduces the use of a microfluidic device that allows for the control of oxygen tension for the study of different three-dimensional (3D) cell cultures for various applications. The device has a central 3D gel region acting as an external cellular matrix, flanked by media channels. On each side, there is a peripheral gas channel through which suitable gas mixtures are supplied to establish a uniform oxygen tension or gradient within the device. The effects of various parameters, such as gas and media flow rates, device thickness, and diffusion coefficients of oxygen were examined using numerical simulations to determine the characteristics of the microfluidic device. A polycarbonate (PC) film with a low oxygen diffusion coefficient was embedded in the device in proximity above the channels to prevent oxygen diffusion from the incubator environment into the polydimethylsiloxane (PDMS) device. The oxygen tension in the device was then validated experimentally using a ruthenium-coated (Ru-coated) oxygen-sensing glass cover slip which confirmed the establishment of low uniform oxygen tensions (<3%) or an oxygen gradient across the gel region. To demonstrate the utility of the microfluidic device for cellular experiments under hypoxic conditions, migratory studies of MDA-MB-231 human breast cancer cells were performed. The microfluidic device allowed for imaging cellular migration with high-resolution, exhibiting an enhanced migration in hypoxia in comparison to normoxia. This microfluidic device presents itself as a promising platform for the investigation of cellular behaviour in a 3D gel scaffold under varying hypoxic conditions.
Collapse
Affiliation(s)
- Kenichi Funamoto
- Institute of Fluid Science, Tohoku University, Sendai 980-8577, Japan
- Department of Biological Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Ioannis K. Zervantonakis
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Yuchun Liu
- BIOMAT, Department of Mechanical Engineering, Faculty of Engineering, National University of Singapore, Singapore 117576, Singapore
- Experimental Fetal Medicine Group, Department of Obstetrics and Gynaecology, Yong Loo Lin School of Medicine, National University of Singapore, Singapore 119228, Singapore
- SMART BioSystems & Micromechanics (BioSyM), Singapore 117543, Singapore
| | - Christopher J. Ochs
- SMART BioSystems & Micromechanics (BioSyM), Singapore 117543, Singapore
- Division of Bioengineering, National University of Singapore, Singapore 117576, Singapore
| | - Choong Kim
- SMART BioSystems & Micromechanics (BioSyM), Singapore 117543, Singapore
- Division of Bioengineering, National University of Singapore, Singapore 117576, Singapore
| | - Roger D. Kamm
- Department of Biological Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
- SMART BioSystems & Micromechanics (BioSyM), Singapore 117543, Singapore
| |
Collapse
|
53
|
Han S, Yan JJ, Shin Y, Jeon JJ, Won J, Jeong HE, Kamm RD, Kim YJ, Chung S. A versatile assay for monitoring in vivo-like transendothelial migration of neutrophils. LAB ON A CHIP 2012; 12:3861-3865. [PMID: 22903230 DOI: 10.1039/c2lc40445a] [Citation(s) in RCA: 76] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
Spatiotemporal analysis of the inflammatory response has been limited by the difficulties of in vivo imaging and reconstitution of inflammation in vitro. Here, we present a novel method for establishing in vivo-like inflammatory models in a microfluidic device and quantitatively measuring the three-dimensional transmigration of neutrophils during the inflammatory process. This enabled us to concurrently characterize transendothelial migration behaviors of neutrophils under the influence of various inflammatory stimuli.
Collapse
Affiliation(s)
- Sewoon Han
- School of Mechanical Engineering, Korea University, South Korea
| | | | | | | | | | | | | | | | | |
Collapse
|
54
|
Choi E, Chang HK, Lim CY, Kim T, Park J. Concentration gradient generation of multiple chemicals using spatially controlled self-assembly of particles in microchannels. LAB ON A CHIP 2012; 12:3968-75. [PMID: 22907568 DOI: 10.1039/c2lc40450h] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
We present a robust microfluidic platform for the stable generation of multiple chemical gradients simultaneously using in situ self-assembly of particles in microchannels. This proposed device enables us to generate stable and reproducible diffusion-based gradients rapidly without convection flow: gradients are stabilized within 5 min and are maintained steady for several hours. Using this device, we demonstrate the dynamic position control of bacteria by introducing the sequential directional change of chemical gradients. Green Fluorescent Protein (GFP)-expressing bacterial cells, allowing quantitative monitoring, show not only tracking motion according to the directional control of chemical gradients, but also the gradual loss of sensitivity when exposed to the sequential attractants because of receptor saturation. In addition, the proposed system can be used to study the preferential chemotaxis assay of bacteria toward multiple chemical sources, since it is possible to produce multiple chemical gradients in the main chamber; aspartate induces the most preferential chemotaxis over galactose and ribose. The microfluidic device can be easily fabricated with a simple and cost effective process based on capillary pressure and evaporation for particle assembly. The assembled particles create uniform porous membranes in microchannels and its porosity can be easily controlled with different size particles. Moreover, the membrane is biocompatible and more robust than hydrogel-based porous membranes. The proposed system is expected to be a useful tool for the characterization of bacterial responses to various chemical sources, screening of bacterial cells, synthetic biology and understanding many cellular activities.
Collapse
Affiliation(s)
- Eunpyo Choi
- Department of Mechanical Engineering, Sogang University, Sinsu-dong, Mapo-gu, Seoul 121-742, Korea
| | | | | | | | | |
Collapse
|
55
|
Kim C, Chung S, Yuchun L, Kim MC, Chan JKY, Asada HH, Kamm RD. In vitro angiogenesis assay for the study of cell-encapsulation therapy. LAB ON A CHIP 2012; 12:2942-2950. [PMID: 22722695 DOI: 10.1039/c2lc40182g] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
Cell encapsulation within alginate beads has potential as a sustained release system for delivering therapeutic agents in vivo while protecting encapsulated cells from the immune system. There is, however, no in vitro model for cell-encapsulation therapy that provides a suitable platform for quantitative assessment of physiological responses to secreted factors. Here we introduce a new microfluidic system specifically designed to evaluate and quantify the pro-angiogenic potential of factors secreted from human fetal lung fibroblasts encapsulated in beads on an intact endothelial cell monolayer. We confirmed that cell-encapsulating beads induced an angiogenic response in vitro, demonstrated by a strong correlation between the encapsulated cell density in the beads and the length of the vascular lumen formed in vitro. Conditions established by in vitro tests were then further shown to exert a pro-angiogenic response in vivo using a subcutaneous mouse model, forming an extensive network of functional luminal structures perfused with red blood cells.
Collapse
Affiliation(s)
- Choong Kim
- Department of Biological Engineering, Massachusetts Institute of Technology, USA
| | | | | | | | | | | | | |
Collapse
|
56
|
|
57
|
Traphagen SB, Titushkin I, Sun S, Wary KK, Cho M. Endothelial invasive response in a co-culture model with physically-induced osteodifferentiation. J Tissue Eng Regen Med 2012; 7:621-30. [PMID: 22696416 DOI: 10.1002/term.554] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2011] [Revised: 08/26/2011] [Accepted: 11/15/2011] [Indexed: 02/06/2023]
Abstract
Manipulation of stem cells using physicochemical stimuli has emerged as an important tool in regenerative medicine. While 2D substrates with tunable elasticity have been studied for control of stem cell differentiation, we recently developed a stratified co-culture model of angiogenesis of human mesenchymal stem cells (hMSCs) that differentiate on a tunable polydimethylsiloxane (PDMS) substrate, thereby creating a physiologic context for elasticity-induced differentiation. Endothelial cells (EC) were cultured on top of the hMSC construct on a collagen gel to monitor network formation. Media composition influenced EC invasion due to the conditioning media, the reduction of serum and supplemental growth factors, and the addition of recombinant growth factors. Conditioned media, recombinant growth factors and direct co-culture were compared for endothelial cell invasive response using quantitative image analysis. As anticipated, use of recombinant vascular endothelial growth factor (VEGF) induced the deepest EC invasions while direct co-culture caused shallow invasions compared to other conditions. However, endothelial cells displayed lumen-like morphology, suggesting that cell-cell interaction in the co-culture model could mimic sprouting behaviour. In summary, an engineered suitable biochemical and physical environment facilitated endothelial cells to form 3D vessel structures onto hMSCs. These structures were plated on a stiff surface known to induce osteodifferentiation of stem cells. This low cost co-culture system, with its minimal chemical supplementation and physically controllable matrix, could potentially model in vivo potential in engineered and pre-vascularized bone grafts.
Collapse
|
58
|
Shin Y, Han S, Jeon JS, Yamamoto K, Zervantonakis IK, Sudo R, Kamm RD, Chung S. Microfluidic assay for simultaneous culture of multiple cell types on surfaces or within hydrogels. Nat Protoc 2012; 7:1247-59. [PMID: 22678430 DOI: 10.1038/nprot.2012.051] [Citation(s) in RCA: 427] [Impact Index Per Article: 32.8] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
This protocol describes a simple but robust microfluidic assay combining three-dimensional (3D) and two-dimensional (2D) cell culture. The microfluidic platform comprises hydrogel-incorporating chambers between surface-accessible microchannels. By using this platform, well-defined biochemical and biophysical stimuli can be applied to multiple cell types interacting over distances of <1 mm, thereby replicating many aspects of the in vivo microenvironment. Capabilities exist for time-dependent manipulation of flow and concentration gradients as well as high-resolution real-time imaging for observing spatial-temporal single-cell behavior, cell-cell communication, cell-matrix interactions and cell population dynamics. These heterotypic cell type assays can be used to study cell survival, proliferation, migration, morphogenesis and differentiation under controlled conditions. Applications include the study of previously unexplored cellular interactions, and they have already provided new insights into how biochemical and biophysical factors regulate interactions between populations of different cell types. It takes 3 d to fabricate the system and experiments can run for up to several weeks.
Collapse
Affiliation(s)
- Yoojin Shin
- School of Mechanical Engineering, Korea University, Seoul, Korea
| | | | | | | | | | | | | | | |
Collapse
|
59
|
Song JW, Bazou D, Munn LL. Anastomosis of endothelial sprouts forms new vessels in a tissue analogue of angiogenesis. Integr Biol (Camb) 2012; 4:857-62. [PMID: 22673771 DOI: 10.1039/c2ib20061a] [Citation(s) in RCA: 77] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Here we describe a microfluidic device that accurately reproduces the dynamics of vascular anastomosis, the process by which vascular sprouts connect to achieve perfusion during angiogenesis. The micro-device features two parallel endothelial cell-lined vessel analogues separated by a 300 μm wide collagenous matrix into which the vessels can sprout and form perfused bridging connections. By accurately recapitulating anastomosis in vitro, the device will enable a new generation of studies of the mechanisms of angiogenesis and provide a novel and practical platform for drug screening.
Collapse
Affiliation(s)
- Jonathan W Song
- Edwin L. Steele Laboratory for Tumour Biology, Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Charlestown, MA 02129, USA
| | | | | |
Collapse
|
60
|
Farahat WA, Wood LB, Zervantonakis IK, Schor A, Ong S, Neal D, Kamm RD, Asada HH. Ensemble analysis of angiogenic growth in three-dimensional microfluidic cell cultures. PLoS One 2012; 7:e37333. [PMID: 22662145 PMCID: PMC3360734 DOI: 10.1371/journal.pone.0037333] [Citation(s) in RCA: 84] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2011] [Accepted: 04/20/2012] [Indexed: 11/19/2022] Open
Abstract
We demonstrate ensemble three-dimensional cell cultures and quantitative analysis of angiogenic growth from uniform endothelial monolayers. Our approach combines two key elements: a micro-fluidic assay that enables parallelized angiogenic growth instances subject to common extracellular conditions, and an automated image acquisition and processing scheme enabling high-throughput, unbiased quantification of angiogenic growth. Because of the increased throughput of the assay in comparison to existing three-dimensional morphogenic assays, statistical properties of angiogenic growth can be reliably estimated. We used the assay to evaluate the combined effects of vascular endothelial growth factor (VEGF) and the signaling lipid sphingoshine-1-phosphate (S1P). Our results show the importance of S1P in amplifying the angiogenic response in the presence of VEGF gradients. Furthermore, the application of S1P with VEGF gradients resulted in angiogenic sprouts with higher aspect ratio than S1P with background levels of VEGF, despite reduced total migratory activity. This implies a synergistic effect between the growth factors in promoting angiogenic activity. Finally, the variance in the computed angiogenic metrics (as measured by ensemble standard deviation) was found to increase linearly with the ensemble mean. This finding is consistent with stochastic agent-based mathematical models of angiogenesis that represent angiogenic growth as a series of independent stochastic cell-level decisions.
Collapse
Affiliation(s)
- Waleed A Farahat
- Department of Mechanical Engineering, Massachusetts Institute of Technology (MIT), Cambridge, Massachusetts, United States of America.
| | | | | | | | | | | | | | | |
Collapse
|
61
|
Abstract
In vitro studies of vascular physiology have traditionally relied on cultures of endothelial cells, smooth muscle cells, and pericytes grown on centimeter-scale plates, filters, and flow chambers. The introduction of microfluidic tools has revolutionized the study of vascular physiology by allowing researchers to create physiologically relevant culture models, at the same time greatly reducing the consumption of expensive reagents. By taking advantage of the small dimensions and laminar flow inherent in microfluidic systems, recent studies have created in vitro models that reproduce many features of the in vivo vascular microenvironment with fine spatial and temporal resolution. In this review, we highlight the advantages of microfluidics in four areas: the investigation of hemodynamics on a capillary length scale, the modulation of fluid streams over vascular cells, angiogenesis induced by the exposure of vascular cells to well-defined gradients in growth factors or pressure, and the growth of microvascular networks in biomaterials. Such unique capabilities at the microscale are rapidly advancing the understanding of microcirculatory dynamics, shear responses, and angiogenesis in health and disease as well as the ability to create in vivo-like blood vessels in vitro.
Collapse
Affiliation(s)
- Keith H K Wong
- Department of Biomedical Engineering, Boston University, Boston, Massachusetts 02215, USA
| | | | | | | |
Collapse
|
62
|
Choi E, Jun I, Chang HK, Park KM, Shin H, Park KD, Park J. Quantitatively controlled in situ formation of hydrogel membranes in microchannels for generation of stable chemical gradients. LAB ON A CHIP 2012; 12:302-8. [PMID: 22108911 DOI: 10.1039/c1lc20777f] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/16/2023]
Abstract
The in situ formation of membranes in microfluidic channels has been given attention because of their great potential in the separation of components, cell culture support for tissue engineering, and molecular transport for generation of chemical gradients. Among these, the porous membranes in microchannels are vigorously applied to generate stable chemical gradients for chemotaxis-dependent cell migration assays. Previous work on the in situ fabrication of membranes for generating the chemical gradient, however, has had several disadvantages, such as fluid leaking, uncontrollable membrane thickness, need of extra equipment, and difficulty in realizing stable interfacial layers. In this paper, we report a novel technique for the in situ formation of membranes within microchannels using enzymatically crosslinkable hydrogels and microfluidic techniques. The thickness of the membrane can be controlled quantitatively by adjusting the crosslinking reaction time and velocity of the microfluidics. By using these techniques, parallel dual hydrogel membranes were prepared within microchannels and these were used for the generation of stable concentration gradients. Moreover, the migration of Salmonella typhimurium was monitored to validate the efficacy of the chemical gradients. These results suggest that our in situ membrane system can be used as a simple platform to understand many cellular activities, including cell adhesion and migration directed by chemotaxis or complex diffusions from biological fluids in three-dimensional microstructures.
Collapse
Affiliation(s)
- Eunpyo Choi
- Department of Mechanical Engineering, Sogang University, Sinsu-dong, Mapo-gu, Seoul, 121-742, Korea
| | | | | | | | | | | | | |
Collapse
|
63
|
Microfluidic assay of endothelial cell migration in 3D interpenetrating polymer semi-network HA-Collagen hydrogel. Biomed Microdevices 2011; 13:717-23. [PMID: 21494794 DOI: 10.1007/s10544-011-9541-7] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
Cell migration through the extracellular matrix (ECM) is one of the key features for physiological and pathological processes such as angiogenesis, cancer metastasis, and wound healing. In particular, the quantitative assay of endothelial cell migration under the well-defined three dimensional (3D) microenvironment is important to analyze the angiogenesis mechanism. In this study, we report a microfluidic assay of endothelial cell sprouting and migration into an interpenetrating polymer semi-network HA-Collagen (SIPNs CH) hydrogel as ECM providing an enhanced in vivo mimicking 3D microenvironment to cells. The microfluidic chip could provide a well-controlled gradient of growth factor to cells, whereas the hydrogel could mimic a well-defined 3D microenvironment in vivo. (In addition/Furthermore, the microfluidic chip gives a well-controlled gradient of growth factor to cells) For this reason, three types of hydrogel, composed of semi-interpenetrating networks of collagen and hyaluronic acid were prepared, and firstly we proved the role of the hydrogel in endothelial cell migration. The diffusion property and swelling ratio of the hydrogel were characterized. It modulated the migration of endothelial cells in quantified manner, also being influenced by additional synthesis of Matrix metalloproteinase(MMP)-sensitive remodeling peptides and Arginine-glycine-lycinee (RGD) cell adhesion peptides. We successfully established a novel cell migration platform by changing major determinants such as ECM material under biochemical synthesis and under growth factor gradients in a microfluidic manner.
Collapse
|
64
|
Jeong GS, Han S, Shin Y, Kwon GH, Kamm RD, Lee SH, Chung S. Sprouting angiogenesis under a chemical gradient regulated by interactions with an endothelial monolayer in a microfluidic platform. Anal Chem 2011; 83:8454-9. [PMID: 21985643 DOI: 10.1021/ac202170e] [Citation(s) in RCA: 81] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
Microfluidic cell culture assays are versatile tools for studying cell migration, particularly angiogenesis. Such assays can deliver precisely controlled linear gradients of chemical stimuli to cultured cells in a microfluidic channel, offering excellent optical resolution and in situ monitoring of cellular morphogenesis in response to a gradient. Microfluidic cell culture assays provide a chemical gradient subject to molecular diffusion, although cellular metabolism can perturb it. The actual gradient perturbed by cells has not been precisely described in the context of regulated cellular morphogenesis. We modeled the chemical gradient in a microfluidic channel by simulating the analyte(VEGF) distribution during cellular interactions. The results were experimentally verified by monitoring sprouting angiogenic response from a monolayer of human umbilical vein endothelial cells (hUVECs) into a type 1 collagen scaffold. The simulation provided a basis for understanding a real distribution of the analyte interrupted by cells in microfluidic device. The new protocol enables one to quantify the morphogenesis of hUVECs under a flat, less-steep, or steep gradient.
Collapse
Affiliation(s)
- Gi Seok Jeong
- Department of Biomedical Engineering, College of Health Science, Korea University, Seoul, Korea
| | | | | | | | | | | | | |
Collapse
|
65
|
DeVolder RJ, Bae H, Lee J, Kong H. Directed blood vessel growth using an angiogenic microfiber/microparticle composite patch. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2011; 23:3139-3143. [PMID: 21618617 DOI: 10.1002/adma.201100823] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/02/2011] [Revised: 04/26/2011] [Indexed: 05/30/2023]
Affiliation(s)
- Ross J DeVolder
- Department of Chemical and Biomolecular Engineering, Institute for Genomic Biology, University of Illinois, 600 South Mathews Avenue, Urbana, IL 61801, USA
| | | | | | | |
Collapse
|
66
|
Jeon JS, Chung S, Kamm RD, Charest JL. Hot embossing for fabrication of a microfluidic 3D cell culture platform. Biomed Microdevices 2011; 13:325-33. [PMID: 21113663 DOI: 10.1007/s10544-010-9496-0] [Citation(s) in RCA: 57] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/18/2023]
Abstract
Clinically relevant studies of cell function in vitro require a physiologically-representative microenvironment possessing aspects such as a 3D extracellular matrix (ECM) and controlled biochemical and biophysical parameters. A polydimethylsiloxane (PDMS) microfluidic system with a 3D collagen gel has previously served for analysis of factors inducing different responses of cells in a 3D microenvironment under controlled biochemical and biophysical parameters. In the present study, applying the known commercially-viable manufacturing methods to a cyclic olefin copolymer (COC) material resulted in a microfluidic device with enhanced 3D gel capabilities, controlled surface properties, and improved potential to serve high-volume applications. Hot embossing and roller lamination molded and sealed the microfluidic device. A combination of oxygen plasma and thermal treatments enhanced the sealing, ensured proper placement of the 3D gel, and created controlled and stable surface properties within the device. Culture of cells in the new device indicated no adverse effects of the COC material or processing as compared to previous PDMS devices. The results demonstrate a methodology to transition microfluidic devices for 3D cell culture from scientific research to high-volume applications with broad clinical impact.
Collapse
Affiliation(s)
- Jessie S Jeon
- Department of Mechanical Engineering, Massachusetts Institute of Technology, 77 Massachusetts Ave., Cambridge, MA 02139, USA
| | | | | | | |
Collapse
|
67
|
Shin Y, Jeon JS, Han S, Jung GS, Shin S, Lee SH, Sudo R, Kamm RD, Chung S. In vitro 3D collective sprouting angiogenesis under orchestrated ANG-1 and VEGF gradients. LAB ON A CHIP 2011; 11:2175-81. [PMID: 21617793 DOI: 10.1039/c1lc20039a] [Citation(s) in RCA: 116] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/16/2023]
Abstract
Sprouting angiogenesis requires a coordinated guidance from a variety of angiogenic factors. Here, we have developed a unique hydrogel incorporating microfluidic platform which mimics the physiological microenvironment in 3D under a precisely orchestrated gradient of soluble angiogenic factors, VEGF and ANG-1. The system enables the quantified investigation in chemotactic response of endothelial cells during the collective angiogenic sprouting process. While the presence of a VEGF gradient alone was sufficient in inducing a greater number of tip cells, addition of ANG-1 to the VEGF gradient enhanced the number of tip cells that are attached to collectively migrated stalk cells. The chemotactic response of tip cells attracted by the VEGF gradient and the stabilizing role of ANG-1 were morphologically investigated, elucidating the 3D co-operative migration of tip and stalk cells as well as their structures. We found that ANG-1 enhanced the connection of the stalk cells with the tip cells, and then the direct connection regulated the morphogenesis and/or life cycle of stalk cells.
Collapse
Affiliation(s)
- Yoojin Shin
- School of Mechanical Engineering, Korea University, 512B, Changui Bldg, 5-1, Anam, Seongbuk, Seoul, 136-713, Korea
| | | | | | | | | | | | | | | | | |
Collapse
|
68
|
Choudhury D, Mo X, Iliescu C, Tan LL, Tong WH, Yu H. Exploitation of physical and chemical constraints for three-dimensional microtissue construction in microfluidics. BIOMICROFLUIDICS 2011; 5:22203. [PMID: 21799710 PMCID: PMC3145229 DOI: 10.1063/1.3593407] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/13/2011] [Accepted: 05/02/2011] [Indexed: 05/06/2023]
Abstract
There are a plethora of approaches to construct microtissues as building blocks for the repair and regeneration of larger and complex tissues. Here we focus on various physical and chemical trapping methods for engineering three-dimensional microtissue constructs in microfluidic systems that recapitulate the in vivo tissue microstructures and functions. Advances in these in vitro tissue models have enabled various applications, including drug screening, disease or injury models, and cell-based biosensors. The future would see strides toward the mesoscale control of even finer tissue microstructures and the scaling of various designs for high throughput applications. These tools and knowledge will establish the foundation for precision engineering of complex tissues of the internal organs for biomedical applications.
Collapse
|
69
|
Zervantonakis IK, Kothapalli CR, Chung S, Sudo R, Kamm RD. Microfluidic devices for studying heterotypic cell-cell interactions and tissue specimen cultures under controlled microenvironments. BIOMICROFLUIDICS 2011; 5:13406. [PMID: 21522496 PMCID: PMC3082343 DOI: 10.1063/1.3553237] [Citation(s) in RCA: 70] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/17/2010] [Accepted: 01/11/2011] [Indexed: 05/04/2023]
Abstract
Microfluidic devices allow for precise control of the cellular and noncellular microenvironment at physiologically relevant length- and time-scales. These devices have been shown to mimic the complex in vivo microenvironment better than conventional in vitro assays, and allow real-time monitoring of homotypic or heterotypic cellular interactions. Microfluidic culture platforms enable new assay designs for culturing multiple different cell populations and∕or tissue specimens under controlled user-defined conditions. Applications include fundamental studies of cell population behaviors, high-throughput drug screening, and tissue engineering. In this review, we summarize recent developments in this field along with studies of heterotypic cell-cell interactions and tissue specimen culture in microfluidic devices from our own laboratory.
Collapse
|
70
|
Shamloo A, Heilshorn SC. Matrix density mediates polarization and lumen formation of endothelial sprouts in VEGF gradients. LAB ON A CHIP 2010; 10:3061-8. [PMID: 20820484 DOI: 10.1039/c005069e] [Citation(s) in RCA: 100] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
Endothelial cell (EC) sprouting morphogenesis is a critical step during angiogenesis, the formation of new blood vessels from existing conduits. Here, three-dimensional sprouting morphogenesis was examined using in vitro microfluidic devices that enabled the separate and simultaneous tuning of biomechanical and soluble biochemical stimuli. Quantitative analysis of endothelial sprout formation demonstrated that the ability of vascular endothelial growth factor (VEGF) to regulate stable sprout formation was mediated by the density of the surrounding collagen/fibronectin matrix. The coordinated migration and proliferation of multiple ECs to form stable sprouts were enhanced at intermediate matrix densities (1.2-1.9 mg ml(-1)), while lower densities resulted in uncoordinated migration (0.3-0.7 mg ml(-1)) and higher densities resulted in broad cell clusters that did not elongate (2.7 mg ml(-1)). Within the permissive range of matrix biomechanics, higher density matrices resulted in shorter, thicker, and slower-growing sprouts. The sprouts in higher density matrices also were more likely to polarize towards higher VEGF concentrations, included more cells per cross-sectional area, and demonstrated more stable lumen formation compared to sprouts in lower density matrices. These results quantitatively demonstrate that matrix density mediates VEGF-induced sprout polarization and lumen formation, potentially by regulating the balance between EC migration rate and proliferation rate.
Collapse
Affiliation(s)
- Amir Shamloo
- Mechanical Engineering, Stanford University, Stanford, CA 94305, USA
| | | |
Collapse
|
71
|
Kim M, Kim T. Diffusion-Based and Long-Range Concentration Gradients of Multiple Chemicals for Bacterial Chemotaxis Assays. Anal Chem 2010; 82:9401-9. [DOI: 10.1021/ac102022q] [Citation(s) in RCA: 56] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Affiliation(s)
- Minseok Kim
- School of Mechanical and Advanced Materials Engineering and School of Nano-Bioscience and Chemical Engineering, Ulsan National Institute of Science and Technology, 100 Banyeon-ri, Ulsan 689-798, Korea
| | - Taesung Kim
- School of Mechanical and Advanced Materials Engineering and School of Nano-Bioscience and Chemical Engineering, Ulsan National Institute of Science and Technology, 100 Banyeon-ri, Ulsan 689-798, Korea
| |
Collapse
|
72
|
Abstract
Biocompatible, degradable polymer scaffolds combined with cells or biological signals are being investigated as alternatives to traditional options for tissue reconstruction and transplantation. These approaches are already in clinical use as engineered tissues that enhance wound healing and skin regeneration. The continued enhancement of these material strategies is highly dependent on the ability to promote rapid and stable neovascularization (new blood vessel formation) within the scaffold. Whereas neovascularization therapies have shown some promise for the treatment of ischemic tissues, vascularization of polymer scaffolds in tissue engineering strategies provides a unique challenge owing to the volume and the complexity of the tissues targeted. In this article, we examine recent advances in research focused on promoting neovascularization in polymer scaffolds for tissue engineering applications. These approaches include the use of growth factors, cells, and novel surgical approaches to both enhance and control the nature of the vascular networks formed. The continued development of these approaches may lead to new tissue engineering strategies for the generation of skin and other tissues or organs.
Collapse
Affiliation(s)
- Georgia Papavasiliou
- Department of Biomedical Engineering, Pritzker Institute of Biomedical Science and Engineering, Illinois Institute of Technology, Chicago, IL 60616, USA
| | | | | |
Collapse
|
73
|
Phelps EA, García AJ. Engineering more than a cell: vascularization strategies in tissue engineering. Curr Opin Biotechnol 2010; 21:704-9. [PMID: 20638268 DOI: 10.1016/j.copbio.2010.06.005] [Citation(s) in RCA: 119] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2010] [Revised: 06/14/2010] [Accepted: 06/15/2010] [Indexed: 12/26/2022]
Abstract
Host integration and performance of engineered tissues have been severely limited by the lack of robust strategies to generate patent vascularization and tissue perfusion. This review highlights a selection of exciting developments in vascularization approaches for tissue engineering research. Current strategies for vascularization in tissue engineering are related to growth factor signaling and delivery, cell transplantation, bioactive smart matrix materials, and directed fabrication. Application of these techniques to in vivo models has resulted in a number of robust host vascular responses, especially with synergistic and engineered bioactive systems. The future outlook of the field includes refinement and development of new technologies for vascularization and combining these techniques with functional repair models for metabolically active tissues and relevant disease states.
Collapse
Affiliation(s)
- Edward A Phelps
- Woodruff School of Mechanical Engineering, Petit Institute for Bioengineering and Bioscience, Georgia Institute of Technology, 315 Ferst Drive, Atlanta, GA 30332, USA
| | | |
Collapse
|