51
|
Wang N, Yang A, Fu Y, Li Y, Yan F. Functionalized Organic Thin Film Transistors for Biosensing. Acc Chem Res 2019; 52:277-287. [PMID: 30620566 DOI: 10.1021/acs.accounts.8b00448] [Citation(s) in RCA: 124] [Impact Index Per Article: 24.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
The rise of organic bioelectronics efficiently bridges the gap between semiconductor devices and biological systems, leading to flexible, lightweight, and low-cost organic bioelectronic devices suitable for health or body signal monitoring. The introduction of organic semiconductors in the devices can soften the boundaries between microelectronic systems and dynamically active cells and tissues. Therefore, organic bioelectronics has attracted much attention recently due to the unique properties and promising applications. Organic thin film transistors (OTFTs), owing to their inherent capability of amplifying received signals, have emerged as one of the state-of-the-art biosensing platforms. The advantages of organic semiconductors in terms of synthetic freedom, low temperature solution processing, biocompatibility, and mechanical flexibility render OTFTs ideal transducers for wearable electronics, e-skin, and implantable devices. How to realize highly sensitive, selective, rapid, and efficient signal capture and extraction of biological recognition events is the major challenge in the design of biosensors. OTFTs are prone to converting the presence or change of target analytes into specific electrical signals even in complex biological systems. More importantly, OTFT sensors can be conveniently functionalized with chemical or biological modifications and exhibit substantially improved device sensitivity and selectivity as well as other analytical figure of merits, including calibration range, linearity, and accuracy. However, the stability and reproducibility of the organic devices need to be further improved. In this Account, we first introduce the unique features of OTFTs for bioelectronic applications. Two typical OTFT configurations, including organic electrochemical transistor (OECT) and electrolyte gated organic field effect transistor (EGOFET), are highlighted in their sensing applications mainly due to the operation of the devices in electrolytes and the combination of ionic and electronic charge transports in the devices. These devices are potentiometric transducers with low working voltages (<1 V) and high sensitivity, and are thus suitable for wearable applications with low power consumption. Second, the functionalization strategies on channel materials, electrolytes, and gate electrodes based on various modification methods and sensing mechanisms are discussed in sequence. In an OECT- or EGOFET-based biosensor, the device performance is particularly sensitive to the physical properties of the two interfaces, including channel/electrolyte and gate/electrolyte interfaces. Any change in the potential drop or capacitance of either interface can influence the channel current substantially. Therefore, the functionalization of the interfaces is critical to the sensing performance. In particular, when an electrochemically active material is modified on the interfaces, the reaction of the analyte catalyzed by the modified material can influence the interface potential and lead to a channel current response much stronger than that of a conventional electrochemical measurement. So the biosensors are much more sensitive than typical analytical methods due to the signal amplification of the transistors. Third, the processing techniques including screen printing and inkjet printing and the possibility for mass production are discussed. The applications of organic transistors in wearable electronics and healthcare monitoring systems, especially the fabric OECT-based biosensors for noninvasive detection, are presented. It is expected that the versatile organic transistors will enable various compact, flexible and disposable biosensors compatible with wearable electronics.
Collapse
Affiliation(s)
- Naixiang Wang
- Department of Applied Physics, The Hong Kong Polytechnic University, Hong Kong
| | - Anneng Yang
- Department of Applied Physics, The Hong Kong Polytechnic University, Hong Kong
| | - Ying Fu
- Department of Applied Physics, The Hong Kong Polytechnic University, Hong Kong
| | - Yuanzhe Li
- Department of Applied Physics, The Hong Kong Polytechnic University, Hong Kong
| | - Feng Yan
- Department of Applied Physics, The Hong Kong Polytechnic University, Hong Kong
| |
Collapse
|
52
|
Liao J, Si H, Zhang X, Lin S. Functional Sensing Interfaces of PEDOT:PSS Organic Electrochemical Transistors for Chemical and Biological Sensors: A Mini Review. SENSORS (BASEL, SWITZERLAND) 2019; 19:E218. [PMID: 30634408 PMCID: PMC6359468 DOI: 10.3390/s19020218] [Citation(s) in RCA: 34] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/03/2018] [Revised: 12/29/2018] [Accepted: 01/05/2019] [Indexed: 02/04/2023]
Abstract
Organic electrochemical transistors (OECTs) are promising devices for applications in in vitro and in vivo measurements. OECTs have two important sensing interfaces for signal monitoring: One is the gate electrode surface; the other is the channel surface. This mini review introduced the new developments in chemical and biological detection of the two sensing interfaces. Specific focus was given on the modification technological approaches of the gate or channel surface. In particular, some unique strategies and surface designs aiming to facilitate signal-transduction and amplification were discussed. Several perspectives and current challenges of OECTs development were also briefly summarized.
Collapse
Affiliation(s)
- Jianjun Liao
- State Key Laboratory of Marine Resource Utilization in South China Sea, Hainan University, Haikou 570228, China.
- College of Ecology and Environment, Hainan University, Haikou 570228, China.
| | - Hewei Si
- State Key Laboratory of Marine Resource Utilization in South China Sea, Hainan University, Haikou 570228, China.
- College of Materials and Chemical Engineering, Hainan University, Haikou 570228, China.
| | - Xidong Zhang
- State Key Laboratory of Marine Resource Utilization in South China Sea, Hainan University, Haikou 570228, China.
- College of Materials and Chemical Engineering, Hainan University, Haikou 570228, China.
| | - Shiwei Lin
- State Key Laboratory of Marine Resource Utilization in South China Sea, Hainan University, Haikou 570228, China.
- College of Materials and Chemical Engineering, Hainan University, Haikou 570228, China.
| |
Collapse
|
53
|
Robinson JT, Pohlmeyer E, Gather MC, Kemere C, Kitching JE, Malliaras GG, Marblestone A, Shepard KL, Stieglitz T, Xie C. Developing Next-generation Brain Sensing Technologies - A Review. IEEE SENSORS JOURNAL 2019; 19:10.1109/jsen.2019.2931159. [PMID: 32116472 PMCID: PMC7047830 DOI: 10.1109/jsen.2019.2931159] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
Advances in sensing technology raise the possibility of creating neural interfaces that can more effectively restore or repair neural function and reveal fundamental properties of neural information processing. To realize the potential of these bioelectronic devices, it is necessary to understand the capabilities of emerging technologies and identify the best strategies to translate these technologies into products and therapies that will improve the lives of patients with neurological and other disorders. Here we discuss emerging technologies for sensing brain activity, anticipated challenges for translation, and perspectives for how to best transition these technologies from academic research labs to useful products for neuroscience researchers and human patients.
Collapse
Affiliation(s)
- Jacob T. Robinson
- Department of Electrical and Computer Engineering, Rice University, Houston, TX 77005, USA
- Department of Bioengineering, Rice University, Houston, TX 77005, USA
- Department of Neuroscience, Baylor College of Medicine, Houston, TX 77030, USA
| | - Eric Pohlmeyer
- John Hopkins University Applied Physics Laboratory, Laurel, MD 20723, USA
| | - Malte C. Gather
- SUPA, School of Physics & Astronomy, University of St Andrews, St Andrews KY16 9SS Scotland, UK
| | - Caleb Kemere
- Department of Electrical and Computer Engineering, Rice University, Houston, TX 77005, USA
- Department of Bioengineering, Rice University, Houston, TX 77005, USA
| | - John E. Kitching
- Time and Frequency Division, NIST, 325 Broadway, Boulder, Colorado 80305, USA
| | - George G. Malliaras
- Electrical Engineering Division, Department of Engineering, University of Cambridge, Cambridge CB3 0FA, UK
| | - Adam Marblestone
- MIT Media Lab, Massachusetts Institute of Technology (MIT), Cambridge, MA 02139, USA
| | - Kenneth L. Shepard
- Department of Electrical Engineering, Columbia University, New York, NY 10027, USA
| | - Thomas Stieglitz
- Institute of Microsystem Technology, Laboratory for Biomedical Microtechnology, D-79110 Freiburg, Germany
- Cluster of Excellence BrainLinks-BrainTools, University of Freiburg, 79110 Freiburg, Germany
- Bernstein Center Freiburg, University of Freiburg, 79104 Freiburg, Germany
| | - Chong Xie
- Department of Biomedical Engineering, The University of Texas at Austin, Austin, TX 78712, USA
| |
Collapse
|
54
|
Ariga K, Makita T, Ito M, Mori T, Watanabe S, Takeya J. Review of advanced sensor devices employing nanoarchitectonics concepts. BEILSTEIN JOURNAL OF NANOTECHNOLOGY 2019; 10:2014-2030. [PMID: 31667049 PMCID: PMC6808193 DOI: 10.3762/bjnano.10.198] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/15/2019] [Accepted: 09/06/2019] [Indexed: 05/09/2023]
Abstract
Many recent advances in sensor technology have been possible due to nanotechnological advancements together with contributions from other research fields. Such interdisciplinary collaborations fit well with the emerging concept of nanoarchitectonics, which is a novel conceptual methodology to engineer functional materials and systems from nanoscale units through the fusion of nanotechnology with other research fields, including organic chemistry, supramolecular chemistry, materials science and biology. In this review article, we discuss recent advancements in sensor devices and sensor materials that take advantage of advanced nanoarchitectonics concepts for improved performance. In the first part, recent progress on sensor systems are roughly classified according to the sensor targets, such as chemical substances, physical conditions, and biological phenomena. In the following sections, advancements in various nanoarchitectonic motifs, including nanoporous structures, ultrathin films, and interfacial effects for improved sensor function are discussed to realize the importance of nanoarchitectonic structures. Many of these examples show that advancements in sensor technology are no longer limited by progress in microfabrication and nanofabrication of device structures - opening a new avenue for highly engineered, high performing sensor systems through the application of nanoarchitectonics concepts.
Collapse
Affiliation(s)
- Katsuhiko Ariga
- WPI-MANA, National Institute for Materials Science, 1-1 Namiki, Tsukuba 305-0044, Japan
- Department of Advanced Materials Science, Graduate School of Frontier Sciences, The University of Tokyo, 5-1-5 Kashiwanoha, Kashiwa 277-8561, Japan
| | - Tatsuyuki Makita
- Department of Advanced Materials Science, Graduate School of Frontier Sciences, The University of Tokyo, 5-1-5 Kashiwanoha, Kashiwa 277-8561, Japan
| | - Masato Ito
- Department of Advanced Materials Science, Graduate School of Frontier Sciences, The University of Tokyo, 5-1-5 Kashiwanoha, Kashiwa 277-8561, Japan
| | - Taizo Mori
- WPI-MANA, National Institute for Materials Science, 1-1 Namiki, Tsukuba 305-0044, Japan
- Department of Advanced Materials Science, Graduate School of Frontier Sciences, The University of Tokyo, 5-1-5 Kashiwanoha, Kashiwa 277-8561, Japan
| | - Shun Watanabe
- Department of Advanced Materials Science, Graduate School of Frontier Sciences, The University of Tokyo, 5-1-5 Kashiwanoha, Kashiwa 277-8561, Japan
| | - Jun Takeya
- WPI-MANA, National Institute for Materials Science, 1-1 Namiki, Tsukuba 305-0044, Japan
- Department of Advanced Materials Science, Graduate School of Frontier Sciences, The University of Tokyo, 5-1-5 Kashiwanoha, Kashiwa 277-8561, Japan
| |
Collapse
|
55
|
Ho D, Ozdemir R, Kim H, Earmme T, Usta H, Kim C. BODIPY-Based Semiconducting Materials for Organic Bulk Heterojunction Photovoltaics and Thin-Film Transistors. Chempluschem 2018; 84:18-37. [PMID: 31950740 DOI: 10.1002/cplu.201800543] [Citation(s) in RCA: 32] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2018] [Revised: 11/22/2018] [Indexed: 12/31/2022]
Abstract
The rapid emergence of organic (opto)electronics as a promising alternative to conventional (opto)electronics has been achieved through the design and development of novel π-conjugated systems. Among various semiconducting structural platforms, 4,4-difluoro-4-bora-3a,4a-diaza-s-indacene (BODIPY) π-systems have recently attracted attention for use in organic thin-films transistors (OTFTs) and organic photovoltaics (OPVs). This Review article provides an overview of the developments in the past 10 years on the structural design and synthesis of BODIPY-based organic semiconductors and their application in OTFT/OPV devices. The findings summarized and discussed here include the most recent breakthroughs in BODIPYs with record-high charge carrier mobilities and power conversion efficiencies (PCEs). The most up-to-date design rationales and discussions providing a strong understanding of structure-property-function relationships in BODIPY-based semiconductors are presented. Thus, this review is expected to inspire new research for future materials developments/applications in this family of molecules.
Collapse
Affiliation(s)
- Dongil Ho
- Department of Chemical and Biomolecular Engineering, Sogang University Mapo-gu, Seoul, 04107, Republic of Korea
| | - Resul Ozdemir
- Department of Materials Science and Nanotechnology Engineering, Abdullah Gul University, Kayseri, 38080, Turkey
| | - Hyungsug Kim
- Department of Chemical and Biomolecular Engineering, Sogang University Mapo-gu, Seoul, 04107, Republic of Korea
| | - Taeshik Earmme
- Department of Chemical Engineering, Hongik University Mapo-gu, Seoul, 04066, Republic of Korea
| | - Hakan Usta
- Department of Materials Science and Nanotechnology Engineering, Abdullah Gul University, Kayseri, 38080, Turkey
| | - Choongik Kim
- Department of Chemical and Biomolecular Engineering, Sogang University Mapo-gu, Seoul, 04107, Republic of Korea
| |
Collapse
|
56
|
Lee MY, Lee HR, Park CH, Han SG, Oh JH. Organic Transistor-Based Chemical Sensors for Wearable Bioelectronics. Acc Chem Res 2018; 51:2829-2838. [PMID: 30403337 DOI: 10.1021/acs.accounts.8b00465] [Citation(s) in RCA: 60] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Bioelectronics for healthcare that monitor the health information on users in real time have stepped into the limelight as crucial electronic devices for the future due to the increased demand for "point-of-care" testing, which is defined as medical diagnostic testing at the time and place of patient care. In contrast to traditional diagnostic testing, which is generally conducted at medical institutions with diagnostic instruments and requires a long time for specimen analysis, point-of-care testing can be accomplished personally at the bedside, and health information on users can be monitored in real time. Advances in materials science and device technology have enabled next-generation electronics, including flexible, stretchable, and biocompatible electronic devices, bringing the commercialization of personalized healthcare devices increasingly within reach, e.g., wearable bioelectronics attached to the body that monitor the health information on users in real time. Additionally, the monitoring of harmful factors in the environment surrounding the user, such as air pollutants, chemicals, and ultraviolet light, is also important for health maintenance because such factors can have short- and long-term detrimental effects on the human body. The precise detection of chemical species from both the human body and the surrounding environment is crucial for personal health care because of the abundant information that such factors can provide when determining a person's health condition. In this respect, sensor applications based on an organic-transistor platform have various advantages, including signal amplification, molecular design capability, low cost, and mechanical robustness (e.g., flexibility and stretchability). This Account covers recent progress in organic transistor-based chemical sensors that detect various chemical species in the human body or the surrounding environment, which will be the core elements of wearable electronic devices. There has been considerable effort to develop high-performance chemical sensors based on organic-transistor platforms through material design and device engineering. Various experimental approaches have been adopted to develop chemical sensors with high sensitivity, selectivity, and stability, including the synthesis of new materials, structural engineering, surface functionalization, and device engineering. In this Account, we first provide a brief introduction to the operating principles of transistor-based chemical sensors. Then we summarize the progress in the fabrication of transistor-based chemical sensors that detect chemical species from the human body (e.g., molecules in sweat, saliva, urine, tears, etc.). We then highlight examples of chemical sensors for detecting harmful chemicals in the environment surrounding the user (e.g., nitrogen oxides, sulfur dioxide, volatile organic compounds, liquid-phase organic solvents, and heavy metal ions). Finally, we conclude this Account with a perspective on the wearable bioelectronics, especially focusing on organic electronic materials and devices.
Collapse
Affiliation(s)
- Moo Yeol Lee
- Department of Chemical Engineering, Pohang University of Science and Technology (POSTECH), 77 Cheongam-ro, Nam-gu, Pohang, Gyeongsangbuk-do 37673, South Korea
- School of Chemical and Biological Engineering, Institute of Chemical Processes, Seoul National University, 1 Gwanak-ro, Gwanak-gu, Seoul 08826, South Korea
| | - Hae Rang Lee
- Department of Chemical Engineering, Pohang University of Science and Technology (POSTECH), 77 Cheongam-ro, Nam-gu, Pohang, Gyeongsangbuk-do 37673, South Korea
- School of Chemical and Biological Engineering, Institute of Chemical Processes, Seoul National University, 1 Gwanak-ro, Gwanak-gu, Seoul 08826, South Korea
| | - Cheol Hee Park
- Department of Chemical Engineering, Pohang University of Science and Technology (POSTECH), 77 Cheongam-ro, Nam-gu, Pohang, Gyeongsangbuk-do 37673, South Korea
- School of Chemical and Biological Engineering, Institute of Chemical Processes, Seoul National University, 1 Gwanak-ro, Gwanak-gu, Seoul 08826, South Korea
| | - Seul Gi Han
- Department of Chemical Engineering, Pohang University of Science and Technology (POSTECH), 77 Cheongam-ro, Nam-gu, Pohang, Gyeongsangbuk-do 37673, South Korea
- School of Chemical and Biological Engineering, Institute of Chemical Processes, Seoul National University, 1 Gwanak-ro, Gwanak-gu, Seoul 08826, South Korea
| | - Joon Hak Oh
- School of Chemical and Biological Engineering, Institute of Chemical Processes, Seoul National University, 1 Gwanak-ro, Gwanak-gu, Seoul 08826, South Korea
| |
Collapse
|
57
|
Li H, Shi W, Song J, Jang HJ, Dailey J, Yu J, Katz HE. Chemical and Biomolecule Sensing with Organic Field-Effect Transistors. Chem Rev 2018; 119:3-35. [DOI: 10.1021/acs.chemrev.8b00016] [Citation(s) in RCA: 223] [Impact Index Per Article: 37.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
Affiliation(s)
- Hui Li
- Department of Materials Science and Engineering, Johns Hopkins University, Baltimore, Maryland 21218, United States
| | - Wei Shi
- Department of Materials Science and Engineering, Johns Hopkins University, Baltimore, Maryland 21218, United States
- State Key Laboratory of Electronic Thin Films and Integrated Devices, School of Optoelectronic Information, University of Electronic Science and Technology of China, Chengdu 610054, People’s Republic of China
| | - Jian Song
- Department of Materials Science and Engineering, Johns Hopkins University, Baltimore, Maryland 21218, United States
| | - Hyun-June Jang
- Department of Materials Science and Engineering, Johns Hopkins University, Baltimore, Maryland 21218, United States
| | - Jennifer Dailey
- Department of Materials Science and Engineering, Johns Hopkins University, Baltimore, Maryland 21218, United States
| | - Junsheng Yu
- State Key Laboratory of Electronic Thin Films and Integrated Devices, School of Optoelectronic Information, University of Electronic Science and Technology of China, Chengdu 610054, People’s Republic of China
| | - Howard E. Katz
- Department of Materials Science and Engineering, Johns Hopkins University, Baltimore, Maryland 21218, United States
| |
Collapse
|
58
|
Piro B, Mattana G, Reisberg S. Transistors for Chemical Monitoring of Living Cells. BIOSENSORS 2018; 8:E65. [PMID: 29973542 PMCID: PMC6164306 DOI: 10.3390/bios8030065] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/11/2018] [Revised: 06/29/2018] [Accepted: 07/02/2018] [Indexed: 12/30/2022]
Abstract
We review here the chemical sensors for pH, glucose, lactate, and neurotransmitters, such as acetylcholine or glutamate, made of organic thin-film transistors (OTFTs), including organic electrochemical transistors (OECTs) and electrolyte-gated OFETs (EGOFETs), for the monitoring of cell activity. First, the various chemicals that are produced by living cells and are susceptible to be sensed in-situ in a cell culture medium are reviewed. Then, we discuss the various materials used to make the substrate onto which cells can be grown, as well as the materials used for making the transistors. The main part of this review discusses the up-to-date transistor architectures that have been described for cell monitoring to date.
Collapse
Affiliation(s)
- Benoît Piro
- University Paris Diderot, Sorbonne Paris Cité, ITODYS, UMR 7086 CNRS, 15 rue J-A de Baïf, 75205 Paris CEDEX 13, France.
| | - Giorgio Mattana
- University Paris Diderot, Sorbonne Paris Cité, ITODYS, UMR 7086 CNRS, 15 rue J-A de Baïf, 75205 Paris CEDEX 13, France.
| | - Steeve Reisberg
- University Paris Diderot, Sorbonne Paris Cité, ITODYS, UMR 7086 CNRS, 15 rue J-A de Baïf, 75205 Paris CEDEX 13, France.
| |
Collapse
|
59
|
Fabrication and Use of Organic Electrochemical Transistors for Sensing of Metabolites in Aqueous Media. APPLIED SCIENCES-BASEL 2018. [DOI: 10.3390/app8060928] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
|
60
|
Pappa AM, Ohayon D, Giovannitti A, Maria IP, Savva A, Uguz I, Rivnay J, McCulloch I, Owens RM, Inal S. Direct metabolite detection with an n-type accumulation mode organic electrochemical transistor. SCIENCE ADVANCES 2018; 4:eaat0911. [PMID: 29942860 PMCID: PMC6014717 DOI: 10.1126/sciadv.aat0911] [Citation(s) in RCA: 120] [Impact Index Per Article: 20.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/23/2018] [Accepted: 05/08/2018] [Indexed: 05/18/2023]
Abstract
The inherent specificity and electrochemical reversibility of enzymes poise them as the biorecognition element of choice for a wide range of metabolites. To use enzymes efficiently in biosensors, the redox centers of the protein should have good electrical communication with the transducing electrode, which requires either the use of mediators or tedious biofunctionalization approaches. We report an all-polymer micrometer-scale transistor platform for the detection of lactate, a significant metabolite in cellular metabolic pathways associated with critical health care conditions. The device embodies a new concept in metabolite sensing where we take advantage of the ion-to-electron transducing qualities of an electron-transporting (n-type) organic semiconductor and the inherent amplification properties of an ion-to-electron converting device, the organic electrochemical transistor. The n-type polymer incorporates hydrophilic side chains to enhance ion transport/injection, as well as to facilitate enzyme conjugation. The material is capable of accepting electrons of the enzymatic reaction and acts as a series of redox centers capable of switching between the neutral and reduced state. The result is a fast, selective, and sensitive metabolite sensor. The advantage of this device compared to traditional amperometric sensors is the amplification of the input signal endowed by the electrochemical transistor circuit and the design simplicity obviating the need for a reference electrode. The combination of redox enzymes and electron-transporting polymers will open up an avenue not only for the field of biosensors but also for the development of enzyme-based electrocatalytic energy generation/storage devices.
Collapse
Affiliation(s)
- Anna Maria Pappa
- Department of Bioelectronics, École Nationale Supérieure des Mines, Centre Microélectronique de Provence, Gardanne 13541, France
- Department of Chemical Engineering and Biotechnology, University of Cambridge, Philippa Fawcett Drive, Cambridge CB3 0AS, UK
| | - David Ohayon
- Biological and Environmental Sciences and Engineering Division, King Abdullah University of Science and Technology (KAUST), Thuwal 23955-6900, Kingdom of Saudi Arabia
| | - Alexander Giovannitti
- Department of Chemistry and Centre for Plastic Electronics, Imperial College London, London SW7 2AZ, UK
| | - Iuliana Petruta Maria
- Department of Chemistry and Centre for Plastic Electronics, Imperial College London, London SW7 2AZ, UK
| | - Achilleas Savva
- Biological and Environmental Sciences and Engineering Division, King Abdullah University of Science and Technology (KAUST), Thuwal 23955-6900, Kingdom of Saudi Arabia
| | - Ilke Uguz
- Department of Bioelectronics, École Nationale Supérieure des Mines, Centre Microélectronique de Provence, Gardanne 13541, France
| | - Jonathan Rivnay
- Department of Biomedical Engineering, Northwestern University, 2145 Sheridan Road, Evanston, IL 60208, USA
- Simpson Querrey Institute for BioNanotechnology, Northwestern University, Chicago, IL 60611, USA
| | - Iain McCulloch
- Department of Chemistry and Centre for Plastic Electronics, Imperial College London, London SW7 2AZ, UK
- Physical Science and Engineering Division, KAUST, Thuwal 23955-6900, Kingdom of Saudi Arabia
| | - Róisín M Owens
- Department of Bioelectronics, École Nationale Supérieure des Mines, Centre Microélectronique de Provence, Gardanne 13541, France
- Department of Chemical Engineering and Biotechnology, University of Cambridge, Philippa Fawcett Drive, Cambridge CB3 0AS, UK
| | - Sahika Inal
- Biological and Environmental Sciences and Engineering Division, King Abdullah University of Science and Technology (KAUST), Thuwal 23955-6900, Kingdom of Saudi Arabia
| |
Collapse
|
61
|
All poly(3,4-ethylenedioxythiophene) organic electrochemical transistor to amplify amperometric signals. Electrochim Acta 2018. [DOI: 10.1016/j.electacta.2018.02.091] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
62
|
Sun H, Vagin M, Wang S, Crispin X, Forchheimer R, Berggren M, Fabiano S. Complementary Logic Circuits Based on High-Performance n-Type Organic Electrochemical Transistors. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2018; 30. [PMID: 29318706 DOI: 10.1002/adma.201704916] [Citation(s) in RCA: 110] [Impact Index Per Article: 18.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/27/2017] [Revised: 11/23/2017] [Indexed: 06/07/2023]
Abstract
Organic electrochemical transistors (OECTs) have been the subject of intense research in recent years. To date, however, most of the reported OECTs rely entirely on p-type (hole transport) operation, while electron transporting (n-type) OECTs are rare. The combination of efficient and stable p-type and n-type OECTs would allow for the development of complementary circuits, dramatically advancing the sophistication of OECT-based technologies. Poor stability in air and aqueous electrolyte media, low electron mobility, and/or a lack of electrochemical reversibility, of available high-electron affinity conjugated polymers, has made the development of n-type OECTs troublesome. Here, it is shown that ladder-type polymers such as poly(benzimidazobenzophenanthroline) (BBL) can successfully work as stable and efficient n-channel material for OECTs. These devices can be easily fabricated by means of facile spray-coating techniques. BBL-based OECTs show high transconductance (up to 9.7 mS) and excellent stability in ambient and aqueous media. It is demonstrated that BBL-based n-type OECTs can be successfully integrated with p-type OECTs to form electrochemical complementary inverters. The latter show high gains and large worst-case noise margin at a supply voltage below 0.6 V.
Collapse
Affiliation(s)
- Hengda Sun
- Laboratory of Organic Electronics, Department of Science and Technology, Linköping University, SE-601 74, Norrköping, Sweden
| | - Mikhail Vagin
- Laboratory of Organic Electronics, Department of Science and Technology, Linköping University, SE-601 74, Norrköping, Sweden
- Department of Physics, Chemistry and Biology, Linköping University, SE-581 83, Linköping, Sweden
| | - Suhao Wang
- Laboratory of Organic Electronics, Department of Science and Technology, Linköping University, SE-601 74, Norrköping, Sweden
| | - Xavier Crispin
- Laboratory of Organic Electronics, Department of Science and Technology, Linköping University, SE-601 74, Norrköping, Sweden
| | - Robert Forchheimer
- Department of Electrical Engineering, Linköping University, SE-581 83, Linköping, Sweden
| | - Magnus Berggren
- Laboratory of Organic Electronics, Department of Science and Technology, Linköping University, SE-601 74, Norrköping, Sweden
| | - Simone Fabiano
- Laboratory of Organic Electronics, Department of Science and Technology, Linköping University, SE-601 74, Norrköping, Sweden
| |
Collapse
|
63
|
Pappa AM, Parlak O, Scheiblin G, Mailley P, Salleo A, Owens RM. Organic Electronics for Point-of-Care Metabolite Monitoring. Trends Biotechnol 2017; 36:45-59. [PMID: 29196057 DOI: 10.1016/j.tibtech.2017.10.022] [Citation(s) in RCA: 50] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2017] [Revised: 09/26/2017] [Accepted: 10/31/2017] [Indexed: 01/14/2023]
Abstract
In this review we focus on demonstrating how organic electronic materials can solve key problems in biosensing thanks to their unique material properties and implementation in innovative device configurations. We highlight specific examples where these materials solve multiple issues related to complex sensing environments, and we benchmark these examples by comparing them to state-of-the-art commercially available sensing using alternative technologies. We have categorized our examples by sample type, focusing on sensing from body fluids in vitro and on wearable sensors, which have attracted significant interest owing to their integration with everyday life activities. We finish by describing a future trend for in vivo, implantable sensors, which aims to build on current progress from sensing in biological fluids ex vivo.
Collapse
Affiliation(s)
- Anna-Maria Pappa
- Department of Bioelectronics, École Nationale Supérieure des Mines, Centre Microélectronique de Provence (CMP)-École Nationale Supérieure des Mines de Saint-Étienne (EMSE), Microélectronique et Objets Communicants (MOC), 13541 Gardanne, France; Department of Chemical Engineering and Biotechnology, University of Cambridge, Cambridge CB3 OAS, UK; Equal contributions
| | - Onur Parlak
- Department of Materials Science and Engineering, Stanford University, Stanford, CA 94305, USA; Equal contributions
| | - Gaetan Scheiblin
- Commissariat à l'Energie Atomique (CEA), Laboratoire d'Électronique des Technologies de l'Information (LETI), MINATEC Campus, 38054 Grenoble, France; Equal contributions
| | - Pascal Mailley
- Commissariat à l'Energie Atomique (CEA), Laboratoire d'Électronique des Technologies de l'Information (LETI), MINATEC Campus, 38054 Grenoble, France
| | - Alberto Salleo
- Department of Materials Science and Engineering, Stanford University, Stanford, CA 94305, USA
| | - Roisin M Owens
- Department of Bioelectronics, École Nationale Supérieure des Mines, Centre Microélectronique de Provence (CMP)-École Nationale Supérieure des Mines de Saint-Étienne (EMSE), Microélectronique et Objets Communicants (MOC), 13541 Gardanne, France; Department of Chemical Engineering and Biotechnology, University of Cambridge, Cambridge CB3 OAS, UK.
| |
Collapse
|
64
|
Transparent, conformable, active multielectrode array using organic electrochemical transistors. Proc Natl Acad Sci U S A 2017; 114:10554-10559. [PMID: 28923928 DOI: 10.1073/pnas.1703886114] [Citation(s) in RCA: 97] [Impact Index Per Article: 13.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Abstract
Mechanically flexible active multielectrode arrays (MEA) have been developed for local signal amplification and high spatial resolution. However, their opaqueness limited optical observation and light stimulation during use. Here, we show a transparent, ultraflexible, and active MEA, which consists of transparent organic electrochemical transistors (OECTs) and transparent Au grid wirings. The transparent OECT is made of Au grid electrodes and has shown comparable performance with OECTs with nontransparent electrodes/wirings. The transparent active MEA realizes the spatial mapping of electrocorticogram electrical signals from an optogenetic rat with 1-mm spacing and shows lower light artifacts than noise level. Our active MEA would open up the possibility of precise investigation of a neural network system with direct light stimulation.
Collapse
|
65
|
Zhang L, Wang G, Wu D, Xiong C, Zheng L, Ding Y, Lu H, Zhang G, Qiu L. Highly selective and sensitive sensor based on an organic electrochemical transistor for the detection of ascorbic acid. Biosens Bioelectron 2017; 100:235-241. [PMID: 28923558 DOI: 10.1016/j.bios.2017.09.006] [Citation(s) in RCA: 55] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2017] [Revised: 08/24/2017] [Accepted: 09/05/2017] [Indexed: 11/28/2022]
Abstract
In this study, an organic electrochemical transistor sensor (OECT) with a molecularly imprinted polymer (MIP)-modified gate electrode was prepared for the detection of ascorbic acid (AA). The combination of the amplification function of an OECT and the selective specificity of MIPs afforded a highly sensitive, selective OECT sensor. Cyclic voltammetry and electrochemical impedance spectroscopy measurements were carried out to monitor the stepwise fabrication of the modified electrodes and the adsorption capacity of the MIP/Au electrodes. Atomic force microscopy was employed for examining the surface morphology of the electrodes. Important detection parameters, pH and detection temperature were optimized. With the change in the relative concentration of AA from 1μM to 100μM, the MIP-OECT sensor exhibited a low detection limit of 10nM (S/N > 3) and a sensitivity of 75.3μA channel current change per decade under optimal conditions. In addition, the MIP-OECT sensor exhibited excellent specific recognition ability to AA, which prevented the interference from other structurally similar compounds (e.g., aspartic acid, glucose, uric acid, glycine, glutathione, H2O2), and common metal ions (K+, Na+, Ca2+, Mg2+, and Fe2+). In addition, a series of vitamin C beverages were analyzed to demonstrate the feasibility of the MIP-OECT sensor. Using the proposed principle, several other sensors with improved performance can be constructed via the modification of organic electrochemical transistors with appropriate MIP films.
Collapse
Affiliation(s)
- Lijun Zhang
- Key Lab of Special Display Technology, Ministry of Education, National Engineering Lab of Special Display Technology, State Key Lab of Advanced Display Technology, Academy of Opto-Electronic Technology, Hefei University of Technology, Hefei 230009, China
| | - Guiheng Wang
- Key Lab of Special Display Technology, Ministry of Education, National Engineering Lab of Special Display Technology, State Key Lab of Advanced Display Technology, Academy of Opto-Electronic Technology, Hefei University of Technology, Hefei 230009, China
| | - Di Wu
- Key Lab of Special Display Technology, Ministry of Education, National Engineering Lab of Special Display Technology, State Key Lab of Advanced Display Technology, Academy of Opto-Electronic Technology, Hefei University of Technology, Hefei 230009, China
| | - Can Xiong
- School of Food Science and Engineering, Hefei University of Technology, Hefei 230009, China
| | - Lei Zheng
- School of Food Science and Engineering, Hefei University of Technology, Hefei 230009, China
| | - Yunsheng Ding
- Key Laboratory of Advanced Functional Materials and Devices, Anhui Province, School of Chemistry and Chemical Engineering, Hefei University of Technology, Hefei 230009, China
| | - Hongbo Lu
- Key Lab of Special Display Technology, Ministry of Education, National Engineering Lab of Special Display Technology, State Key Lab of Advanced Display Technology, Academy of Opto-Electronic Technology, Hefei University of Technology, Hefei 230009, China; Key Laboratory of Advanced Functional Materials and Devices, Anhui Province, School of Chemistry and Chemical Engineering, Hefei University of Technology, Hefei 230009, China
| | - Guobing Zhang
- Key Lab of Special Display Technology, Ministry of Education, National Engineering Lab of Special Display Technology, State Key Lab of Advanced Display Technology, Academy of Opto-Electronic Technology, Hefei University of Technology, Hefei 230009, China; Key Laboratory of Advanced Functional Materials and Devices, Anhui Province, School of Chemistry and Chemical Engineering, Hefei University of Technology, Hefei 230009, China
| | - Longzhen Qiu
- Key Lab of Special Display Technology, Ministry of Education, National Engineering Lab of Special Display Technology, State Key Lab of Advanced Display Technology, Academy of Opto-Electronic Technology, Hefei University of Technology, Hefei 230009, China; Key Laboratory of Advanced Functional Materials and Devices, Anhui Province, School of Chemistry and Chemical Engineering, Hefei University of Technology, Hefei 230009, China.
| |
Collapse
|
66
|
Curto VF, Marchiori B, Hama A, Pappa AM, Ferro MP, Braendlein M, Rivnay J, Fiocchi M, Malliaras GG, Ramuz M, Owens RM. Organic transistor platform with integrated microfluidics for in-line multi-parametric in vitro cell monitoring. MICROSYSTEMS & NANOENGINEERING 2017; 3:17028. [PMID: 31057869 PMCID: PMC6445009 DOI: 10.1038/micronano.2017.28] [Citation(s) in RCA: 46] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/23/2017] [Revised: 03/31/2017] [Accepted: 04/10/2017] [Indexed: 05/02/2023]
Abstract
Future drug discovery and toxicology testing could benefit significantly from more predictive and multi-parametric readouts from in vitro models. Despite the recent advances in the field of microfluidics, and more recently organ-on-a-chip technology, there is still a high demand for real-time monitoring systems that can be readily embedded with microfluidics. In addition, multi-parametric monitoring is essential to improve the predictive quality of the data used to inform clinical studies that follow. Here we present a microfluidic platform integrated with in-line electronic sensors based on the organic electrochemical transistor. Our goals are two-fold, first to generate a platform to host cells in a more physiologically relevant environment (using physiologically relevant fluid shear stress (FSS)) and second to show efficient integration of multiple different methods for assessing cell morphology, differentiation, and integrity. These include optical imaging, impedance monitoring, metabolite sensing, and a wound-healing assay. We illustrate the versatility of this multi-parametric monitoring in giving us increased confidence to validate the improved differentiation of cells toward a physiological profile under FSS, thus yielding more accurate data when used to assess the effect of drugs or toxins. Overall, this platform will enable high-content screening for in vitro drug discovery and toxicology testing and bridges the existing gap in the integration of in-line sensors in microfluidic devices.
Collapse
Affiliation(s)
- Vincenzo F. Curto
- Department of Bioelectronics, Ecole Nationale Supérieure des Mines, CMP-EMSE, MOC, 880 Avenue de Mimet, Gardanne 13541, France
| | - Bastien Marchiori
- Department of Bioelectronics, Ecole Nationale Supérieure des Mines, CMP-EMSE, MOC, 880 Avenue de Mimet, Gardanne 13541, France
- Flexible Electronics Department, Ecole Nationale Supérieure des Mines CMP-EMSE, MOC, 880 Avenue de Mimet, Gardanne 13541, France
| | - Adel Hama
- Department of Bioelectronics, Ecole Nationale Supérieure des Mines, CMP-EMSE, MOC, 880 Avenue de Mimet, Gardanne 13541, France
| | - Anna-Maria Pappa
- Department of Bioelectronics, Ecole Nationale Supérieure des Mines, CMP-EMSE, MOC, 880 Avenue de Mimet, Gardanne 13541, France
| | - Magali P. Ferro
- Department of Bioelectronics, Ecole Nationale Supérieure des Mines, CMP-EMSE, MOC, 880 Avenue de Mimet, Gardanne 13541, France
| | - Marcel Braendlein
- Department of Bioelectronics, Ecole Nationale Supérieure des Mines, CMP-EMSE, MOC, 880 Avenue de Mimet, Gardanne 13541, France
| | - Jonathan Rivnay
- Department of Bioelectronics, Ecole Nationale Supérieure des Mines, CMP-EMSE, MOC, 880 Avenue de Mimet, Gardanne 13541, France
| | - Michel Fiocchi
- Department of Bioelectronics, Ecole Nationale Supérieure des Mines, CMP-EMSE, MOC, 880 Avenue de Mimet, Gardanne 13541, France
| | - George G. Malliaras
- Department of Bioelectronics, Ecole Nationale Supérieure des Mines, CMP-EMSE, MOC, 880 Avenue de Mimet, Gardanne 13541, France
| | - Marc Ramuz
- Flexible Electronics Department, Ecole Nationale Supérieure des Mines CMP-EMSE, MOC, 880 Avenue de Mimet, Gardanne 13541, France
| | - Róisín M. Owens
- Department of Bioelectronics, Ecole Nationale Supérieure des Mines, CMP-EMSE, MOC, 880 Avenue de Mimet, Gardanne 13541, France
| |
Collapse
|