51
|
Jha RR, Pathak SK, Nath V, Schneider W, Kumar BVR, Bhavsar A, Nigam A. VRfRNet: Volumetric ROI fODF reconstruction network for estimation of multi-tissue constrained spherical deconvolution with only single shell dMRI. Magn Reson Imaging 2022; 90:1-16. [PMID: 35341904 DOI: 10.1016/j.mri.2022.03.004] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2021] [Revised: 02/19/2022] [Accepted: 03/19/2022] [Indexed: 10/18/2022]
Abstract
Diffusion MRI (dMRI) is one of the most popular techniques for studying the brain structure, mainly the white matter region. Among several sampling methods in dMRI, the high angular resolution diffusion imaging (HARDI) technique has attracted researchers due to its more accurate fiber orientation estimation. However, the current single-shell HARDI makes the intravoxel structure challenging to estimate accurately. While multi-shell acquisition can address this problem, it takes a longer scanning time, restricting its use in clinical applications. In addition, most existing dMRI scanners with low gradient-strengths often acquire single-shell up to b=1000s/mm2 because of signal-to-noise ratio issues and severe image artefacts. Hence, we propose a novel generative adversarial network, VRfRNet, for the reconstruction of multi-shell multi-tissue fiber orientation distribution function from single-shell HARDI volumes. Such a transformation learning is performed in the spherical harmonics (SH) space, as raw input HARDI volume is transformed to SH coefficients to soften gradient directions. The proposed VRfRNet consists of several modules, such as multi-context feature enrichment module, feature level attention, and softmax level attention. In addition, three loss functions have been used to optimize network learning, including L1, adversarial, and total variation. The network is trained and tested using standard qualitative and quantitative performance metrics on the publicly available HCP data-set.
Collapse
Affiliation(s)
- Ranjeet Ranjan Jha
- MANAS Lab, School of Computing and Electrical Engineering (SCEE), Indian Institute of Technology (IIT) Mandi, India.
| | - Sudhir K Pathak
- Learning Research and Development Center, University of Pittsburgh, USA
| | - Vishwesh Nath
- Vanderbilt Institute for Surgery and Engineering, Nashville, Tennessee, USA
| | - Walter Schneider
- Learning Research and Development Center, University of Pittsburgh, USA
| | - B V Rathish Kumar
- Department of Mathematics and Statistics, Indian Institute of Technology Kanpur, India
| | - Arnav Bhavsar
- MANAS Lab, School of Computing and Electrical Engineering (SCEE), Indian Institute of Technology (IIT) Mandi, India
| | - Aditya Nigam
- MANAS Lab, School of Computing and Electrical Engineering (SCEE), Indian Institute of Technology (IIT) Mandi, India
| |
Collapse
|
52
|
Grussu F, Bernatowicz K, Casanova-Salas I, Castro N, Nuciforo P, Mateo J, Barba I, Perez-Lopez R. Diffusion MRI signal cumulants and hepatocyte microstructure at fixed diffusion time: Insights from simulations, 9.4T imaging, and histology. Magn Reson Med 2022; 88:365-379. [PMID: 35181943 PMCID: PMC9303340 DOI: 10.1002/mrm.29174] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2021] [Revised: 12/21/2021] [Accepted: 01/07/2022] [Indexed: 11/09/2022]
Abstract
Purpose Relationships between diffusion‐weighted MRI signals and hepatocyte microstructure were investigated to inform liver diffusion MRI modeling, focusing on the following question: Can cell size and diffusivity be estimated at fixed diffusion time, realistic SNR, and negligible contribution from extracellular/extravascular water and exchange? Methods Monte Carlo simulations were performed within synthetic hepatocytes for varying cell size/diffusivity L/D0, and clinical protocols (single diffusion encoding; maximum b‐value: {1000, 1500, 2000} s/mm2; 5 unique gradient duration/separation pairs; SNR = {∞, 100, 80, 40, 20}), accounting for heterogeneity in (D0,L) and perfusion contamination. Diffusion (D) and kurtosis (K) coefficients were calculated, and relationships between (D0,L) and (D,K) were visualized. Functions mapping (D,K) to (D0,L) were computed to predict unseen (D0,L) values, tested for their ability to classify discrete cell‐size contrasts, and deployed on 9.4T ex vivo MRI‐histology data of fixed mouse livers Results Relationships between (D,K) and (D0,L) are complex and depend on the diffusion encoding. Functions mapping D,K to (D0,L) captures salient characteristics of D0(D,K) and L(D,K) dependencies. Mappings are not always accurate, but they enable just under 70% accuracy in a three‐class cell‐size classification task (for SNR = 20, bmax = 1500 s/mm2, δ = 20 ms, and Δ = 75 ms). MRI detects cell‐size contrasts in the mouse livers that are confirmed by histology, but overestimates the largest cell sizes. Conclusion Salient information about liver cell size and diffusivity may be retrieved from minimal diffusion encodings at fixed diffusion time, in experimental conditions and pathological scenarios for which extracellular, extravascular water and exchange are negligible.
Collapse
Affiliation(s)
- Francesco Grussu
- Radiomics Group, Vall d'Hebron Institute of Oncology, Vall d'Hebron Barcelona Hospital Campus, Barcelona, Spain
| | - Kinga Bernatowicz
- Radiomics Group, Vall d'Hebron Institute of Oncology, Vall d'Hebron Barcelona Hospital Campus, Barcelona, Spain
| | - Irene Casanova-Salas
- Prostate Cancer Translational Research Group, Vall d'Hebron Institute of Oncology, Vall d'Hebron Barcelona Hospital Campus, Barcelona, Spain
| | - Natalia Castro
- Prostate Cancer Translational Research Group, Vall d'Hebron Institute of Oncology, Vall d'Hebron Barcelona Hospital Campus, Barcelona, Spain
| | - Paolo Nuciforo
- Molecular Oncology Group, Vall d'Hebron Institute of Oncology, Vall d'Hebron Barcelona Hospital Campus, Barcelona, Spain
| | - Joaquin Mateo
- Prostate Cancer Translational Research Group, Vall d'Hebron Institute of Oncology, Vall d'Hebron Barcelona Hospital Campus, Barcelona, Spain
| | - Ignasi Barba
- NMR Lab, Vall d'Hebron Institute of Oncology, Vall d'Hebron Barcelona Hospital Campus, Barcelona, Spain
| | - Raquel Perez-Lopez
- Radiomics Group, Vall d'Hebron Institute of Oncology, Vall d'Hebron Barcelona Hospital Campus, Barcelona, Spain.,Department of Radiology, Hospital Universitari Vall d'Hebron, Barcelona, Spain
| |
Collapse
|
53
|
A Clustering Approach to Improve IntraVoxel Incoherent Motion Maps from DW-MRI Using Conditional Auto-Regressive Bayesian Model. APPLIED SCIENCES-BASEL 2022. [DOI: 10.3390/app12041907] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
The Intra-Voxel Incoherent Motion (IVIM) model allows to estimate water diffusion and perfusion-related coefficients in biological tissues using diffusion weighted MR images. Among the available approaches to fit the IVIM bi-exponential decay, a segmented Bayesian algorithm with a Conditional Auto-Regressive (CAR) prior spatial regularization has been recently proposed to produce more reliable coefficient estimation. However, the CAR spatial regularization can generate inaccurate coefficient estimation, especially at the interfaces between different tissues. To overcome this problem, the segmented CAR model was coupled in this work with a k-means clustering approach, to separate different tissues and exclude voxels from other regions in the CAR prior specification. The proposed approach was compared with the original Bayesian CAR method without clustering and with a state-of-the-art Bayesian approach without CAR. The approaches were tested and compared on simulated images by calculating the estimation error and the coefficient of variation (CV). Furthermore, the proposed method was applied to some illustrative real images of oncologic patients. On simulated images, the proposed innovation reduced the average error of 47%, 21% and 58% for D, f and D*, respectively, compared to the state-of-the-art Bayesian approach, and of 48% and 34% for D and f, respectively, compared to the original CAR, while it achieved the same error for D*. The clustering approach was also able to consistently reduce the CV for each coefficient. On real images, the novel approach did not alter the IVIM maps obtained by the original CAR method, with the advantage of reducing their typical blotchy appearance at the boundaries. The proposed approach represents a valuable improvement over the state-of-the-art Bayesian CAR method and provides more reliable IVIM coefficient estimation, and is less sensitive to bias and inconsistency at tissue/tissue and tissue/background interfaces.
Collapse
|
54
|
Vasylechko SD, Warfield SK, Afacan O, Kurugol S. Self-supervised IVIM DWI parameter estimation with a physics based forward model. Magn Reson Med 2022; 87:904-914. [PMID: 34687065 PMCID: PMC8627432 DOI: 10.1002/mrm.28989] [Citation(s) in RCA: 21] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2021] [Revised: 07/29/2021] [Accepted: 08/08/2021] [Indexed: 02/03/2023]
Abstract
PURPOSE To assess the robustness and repeatability of intravoxel incoherent motion model (IVIM) parameter estimation for the diffusion-weighted MRI in the abdominal organs under the constraints of noisy diffusion signal using a novel neural network method. METHODS Clinically acquired abdominal scans of Crohn's disease patients were retrospectively analyzed with regions segmented in the kidney cortex, spleen, liver, and bowel. A novel IVIM parameter fitting method based on the principle of a physics guided self-supervised convolutional neural network that does not require reference parameter estimates for training was compared to a conventional non-linear least squares (NNLS) algorithm, and a voxelwise trained artificial neural network (ANN). RESULTS Results showed substantial increase in parameter robustness to the noise corrupted signal. In an intra-session repeatability experiment, the proposed method showed reduced coefficient of variation (CoV) over multiple acquisitions in comparison to conventional NLLS method and comparable performance to ANN. The use of D and f estimates from the proposed method led to the smallest misclassification error in linear discriminant analysis for characterization between normal and abnormal Crohn's disease bowel tissue. The fitting of D∗ parameter remains to be challenging. CONCLUSION The proposed method yields robust estimates of D and f IVIM parameters under the constraints of noisy diffusion signal. This indicates a potential for the use of the proposed method in conjunction with accelerated DW-MRI acquisition strategies, which would typically result in lower signal to noise ratio.
Collapse
Affiliation(s)
- Serge Didenko Vasylechko
- Computational Radiology Laboratory, Boston Children’s Hospital, Boston, MA, USA
- Harvard Medical School, Boston, MA, USA
- Corresponding author: Name Serge Didenko Vasylechko, Department Computational Radiology Laboratory, Institute Boston Children’s Hospital, Address 360 Longwood Avenue, Boston, MA, 02215, USA,
| | - Simon K. Warfield
- Computational Radiology Laboratory, Boston Children’s Hospital, Boston, MA, USA
- Harvard Medical School, Boston, MA, USA
| | - Onur Afacan
- Computational Radiology Laboratory, Boston Children’s Hospital, Boston, MA, USA
- Harvard Medical School, Boston, MA, USA
| | - Sila Kurugol
- Computational Radiology Laboratory, Boston Children’s Hospital, Boston, MA, USA
- Harvard Medical School, Boston, MA, USA
| |
Collapse
|
55
|
Zhou X, Wang X, Liu E, Zhang L, Zhang H, Zhang X, Zhu Y, Kuai Z. An Unsupervised Deep Learning Approach for
Dynamic‐Exponential
Intravoxel Incoherent Motion
MRI
Modeling and Parameter Estimation in the Liver. J Magn Reson Imaging 2022; 56:848-859. [PMID: 35064945 DOI: 10.1002/jmri.28074] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2021] [Revised: 01/09/2022] [Accepted: 01/10/2022] [Indexed: 12/18/2022] Open
Affiliation(s)
- Xin‐Xiang Zhou
- Imaging Center Harbin Medical University Cancer Hospital Harbin China
| | - Xin‐Yu Wang
- Imaging Center Harbin Medical University Cancer Hospital Harbin China
| | - En‐Hui Liu
- Imaging Center Harbin Medical University Cancer Hospital Harbin China
| | - Lan Zhang
- Imaging Center Harbin Medical University Cancer Hospital Harbin China
| | - Hong‐Xia Zhang
- Imaging Center Harbin Medical University Cancer Hospital Harbin China
| | - Xiu‐Shi Zhang
- Imaging Center Harbin Medical University Cancer Hospital Harbin China
| | - Yue‐Min Zhu
- CREATIS CNRS UMR 5220‐INSERM U1206‐University Lyon 1‐INSA Lyon‐University Jean Monnet Saint‐Etienne Lyon France
| | - Zi‐Xiang Kuai
- Imaging Center Harbin Medical University Cancer Hospital Harbin China
| |
Collapse
|
56
|
de Almeida Martins JP, Nilsson M, Lampinen B, Palombo M, While PT, Westin CF, Szczepankiewicz F. Neural networks for parameter estimation in microstructural MRI: Application to a diffusion-relaxation model of white matter. Neuroimage 2021; 244:118601. [PMID: 34562578 PMCID: PMC9651573 DOI: 10.1016/j.neuroimage.2021.118601] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2021] [Revised: 08/26/2021] [Accepted: 09/18/2021] [Indexed: 12/14/2022] Open
Abstract
Specific features of white matter microstructure can be investigated by using biophysical models to interpret relaxation-diffusion MRI brain data. Although more intricate models have the potential to reveal more details of the tissue, they also incur time-consuming parameter estimation that may converge to inaccurate solutions due to a prevalence of local minima in a degenerate fitting landscape. Machine-learning fitting algorithms have been proposed to accelerate the parameter estimation and increase the robustness of the attained estimates. So far, learning-based fitting approaches have been restricted to microstructural models with a reduced number of independent model parameters where dense sets of training data are easy to generate. Moreover, the degree to which machine learning can alleviate the degeneracy problem is poorly understood. For conventional least-squares solvers, it has been shown that degeneracy can be avoided by acquisition with optimized relaxation-diffusion-correlation protocols that include tensor-valued diffusion encoding. Whether machine-learning techniques can offset these acquisition requirements remains to be tested. In this work, we employ artificial neural networks to vastly accelerate the parameter estimation for a recently introduced relaxation-diffusion model of white matter microstructure. We also develop strategies for assessing the accuracy and sensitivity of function fitting networks and use those strategies to explore the impact of the acquisition protocol. The developed learning-based fitting pipelines were tested on relaxation-diffusion data acquired with optimal and sub-optimal acquisition protocols. Networks trained with an optimized protocol were observed to provide accurate parameter estimates within short computational times. Comparing neural networks and least-squares solvers, we found the performance of the former to be less affected by sub-optimal protocols; however, model fitting networks were still susceptible to degeneracy issues and their use could not fully replace a careful design of the acquisition protocol.
Collapse
Affiliation(s)
- João P de Almeida Martins
- Department of Clinical Sciences, Radiology, Lund University, Lund, Sweden; Department of Radiology and Nuclear Medicine, St. Olav's University Hospital, Trondheim, Norway.
| | - Markus Nilsson
- Department of Clinical Sciences, Radiology, Lund University, Lund, Sweden
| | - Björn Lampinen
- Department of Clinical Sciences, Medical Radiation Physics, Lund University, Lund, Sweden
| | - Marco Palombo
- Centre for Medical Image Computing and Department of Computer Science, University College London, London, United Kingdom
| | - Peter T While
- Department of Radiology and Nuclear Medicine, St. Olav's University Hospital, Trondheim, Norway; Department of Circulation and Medical Imaging, NTNU-Norwegian University of Science and Technology, Trondheim, Norway
| | - Carl-Fredrik Westin
- Radiology, Brigham and Women's Hospital, Boston, MA, United States; Harvard Medical School, Boston, MA, United States
| | - Filip Szczepankiewicz
- Department of Clinical Sciences, Radiology, Lund University, Lund, Sweden; Radiology, Brigham and Women's Hospital, Boston, MA, United States; Harvard Medical School, Boston, MA, United States
| |
Collapse
|
57
|
Moya-Sáez E, Peña-Nogales Ó, Luis-García RD, Alberola-López C. A deep learning approach for synthetic MRI based on two routine sequences and training with synthetic data. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2021; 210:106371. [PMID: 34525411 DOI: 10.1016/j.cmpb.2021.106371] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/10/2021] [Accepted: 08/18/2021] [Indexed: 06/13/2023]
Abstract
BACKGROUND AND OBJECTIVE Synthetic magnetic resonance imaging (MRI) is a low cost procedure that serves as a bridge between qualitative and quantitative MRI. However, the proposed methods require very specific sequences or private protocols which have scarcely found integration in clinical scanners. We propose a learning-based approach to compute T1, T2, and PD parametric maps from only a pair of T1- and T2-weighted images customarily acquired in the clinical routine. METHODS Our approach is based on a convolutional neural network (CNN) trained with synthetic data; specifically, a synthetic dataset with 120 volumes was constructed from the anatomical brain model of the BrainWeb tool and served as the training set. The CNN learns an end-to-end mapping function to transform the input T1- and T2-weighted images to their underlying T1, T2, and PD parametric maps. Then, conventional weighted images unseen by the network are analytically synthesized from the parametric maps. The network can be fine tuned with a small database of actual weighted images and maps for better performance. RESULTS This approach is able to accurately compute parametric maps from synthetic brain data achieving normalized squared error values predominantly below 1%. It also yields realistic parametric maps from actual MR brain acquisitions with T1, T2, and PD values in the range of the literature and with correlation values above 0.95 compared to the T1 and T2 maps obtained from relaxometry sequences. Further, the synthesized weighted images are visually realistic; the mean square error values are always below 9% and the structural similarity index is usually above 0.90. Network fine tuning with actual maps improves performance, while training exclusively with a small database of actual maps shows a performance degradation. CONCLUSIONS These results show that our approach is able to provide realistic parametric maps and weighted images out of a CNN that (a) is trained with a synthetic dataset and (b) needs only two inputs, which are in turn obtained from a common full-brain acquisition that takes less than 8 min of scan time. Although a fine tuning with actual maps improves performance, synthetic data is crucial to reach acceptable performance levels. Hence, we show the utility of our approach for both quantitative MRI in clinical viable times and for the synthesis of additional weighted images to those actually acquired.
Collapse
Affiliation(s)
- Elisa Moya-Sáez
- Laboratorio de Procesado de Imagen, Universidad de Valladolid, Valladolid, Spain. http://www.lpi.tel.uva.es
| | - Óscar Peña-Nogales
- Laboratorio de Procesado de Imagen, Universidad de Valladolid, Valladolid, Spain
| | | | | |
Collapse
|
58
|
Kaandorp MPT, Barbieri S, Klaassen R, van Laarhoven HWM, Crezee H, While PT, Nederveen AJ, Gurney‐Champion OJ. Improved unsupervised physics-informed deep learning for intravoxel incoherent motion modeling and evaluation in pancreatic cancer patients. Magn Reson Med 2021; 86:2250-2265. [PMID: 34105184 PMCID: PMC8362093 DOI: 10.1002/mrm.28852] [Citation(s) in RCA: 40] [Impact Index Per Article: 13.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2020] [Revised: 04/30/2021] [Accepted: 05/03/2021] [Indexed: 12/12/2022]
Abstract
PURPOSE Earlier work showed that IVIM-NETorig , an unsupervised physics-informed deep neural network, was faster and more accurate than other state-of-the-art intravoxel-incoherent motion (IVIM) fitting approaches to diffusion-weighted imaging (DWI). This study presents a substantially improved version, IVIM-NEToptim , and characterizes its superior performance in pancreatic cancer patients. METHOD In simulations (signal-to-noise ratio [SNR] = 20), the accuracy, independence, and consistency of IVIM-NET were evaluated for combinations of hyperparameters (fit S0, constraints, network architecture, number of hidden layers, dropout, batch normalization, learning rate), by calculating the normalized root-mean-square error (NRMSE), Spearman's ρ, and the coefficient of variation (CVNET ), respectively. The best performing network, IVIM-NEToptim was compared to least squares (LS) and a Bayesian approach at different SNRs. IVIM-NEToptim 's performance was evaluated in an independent dataset of 23 patients with pancreatic ductal adenocarcinoma. Fourteen of the patients received no treatment between two repeated scan sessions and nine received chemoradiotherapy between the repeated sessions. Intersession within-subject standard deviations (wSD) and treatment-induced changes were assessed. RESULTS In simulations (SNR = 20), IVIM-NEToptim outperformed IVIM-NETorig in accuracy (NRMSE(D) = 0.177 vs 0.196; NMRSE(f) = 0.220 vs 0.267; NMRSE(D*) = 0.386 vs 0.393), independence (ρ(D*, f) = 0.22 vs 0.74), and consistency (CVNET (D) = 0.013 vs 0.104; CVNET (f) = 0.020 vs 0.054; CVNET (D*) = 0.036 vs 0.110). IVIM-NEToptim showed superior performance to the LS and Bayesian approaches at SNRs < 50. In vivo, IVIM-NEToptim showed significantly less noisy parameter maps with lower wSD for D and f than the alternatives. In the treated cohort, IVIM-NEToptim detected the most individual patients with significant parameter changes compared to day-to-day variations. CONCLUSION IVIM-NEToptim is recommended for accurate, informative, and consistent IVIM fitting to DWI data.
Collapse
Affiliation(s)
- Misha P. T. Kaandorp
- Department of Radiology and Nuclear MedicineCancer Center Amsterdam, Amsterdam UMC, University of AmsterdamAmsterdamthe Netherlands
- Department of Radiology and Nuclear MedicineSt. Olav’s University HospitalTrondheimNorway
- Department of Circulation and Medical ImagingNTNU – Norwegian University of Science and TechnologyTrondheimNorway
| | | | - Remy Klaassen
- Department of Medical OncologyCancer Center Amsterdam, Amsterdam UMC, University of AmsterdamAmsterdamthe Netherlands
| | - Hanneke W. M. van Laarhoven
- Department of Medical OncologyCancer Center Amsterdam, Amsterdam UMC, University of AmsterdamAmsterdamthe Netherlands
| | - Hans Crezee
- Department of Radiology and Nuclear MedicineCancer Center Amsterdam, Amsterdam UMC, University of AmsterdamAmsterdamthe Netherlands
| | - Peter T. While
- Department of Radiology and Nuclear MedicineSt. Olav’s University HospitalTrondheimNorway
- Department of Circulation and Medical ImagingNTNU – Norwegian University of Science and TechnologyTrondheimNorway
| | - Aart J. Nederveen
- Department of Radiology and Nuclear MedicineCancer Center Amsterdam, Amsterdam UMC, University of AmsterdamAmsterdamthe Netherlands
| | - Oliver J. Gurney‐Champion
- Department of Radiology and Nuclear MedicineCancer Center Amsterdam, Amsterdam UMC, University of AmsterdamAmsterdamthe Netherlands
| |
Collapse
|
59
|
Gyori NG, Palombo M, Clark CA, Zhang H, Alexander DC. Training data distribution significantly impacts the estimation of tissue microstructure with machine learning. Magn Reson Med 2021; 87:932-947. [PMID: 34545955 DOI: 10.1002/mrm.29014] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2021] [Revised: 08/30/2021] [Accepted: 08/30/2021] [Indexed: 12/18/2022]
Abstract
PURPOSE Supervised machine learning (ML) provides a compelling alternative to traditional model fitting for parameter mapping in quantitative MRI. The aim of this work is to demonstrate and quantify the effect of different training data distributions on the accuracy and precision of parameter estimates when supervised ML is used for fitting. METHODS We fit a two- and three-compartment biophysical model to diffusion measurements from in-vivo human brain, as well as simulated diffusion data, using both traditional model fitting and supervised ML. For supervised ML, we train several artificial neural networks, as well as random forest regressors, on different distributions of ground truth parameters. We compare the accuracy and precision of parameter estimates obtained from the different estimation approaches using synthetic test data. RESULTS When the distribution of parameter combinations in the training set matches those observed in healthy human data sets, we observe high precision, but inaccurate estimates for atypical parameter combinations. In contrast, when training data is sampled uniformly from the entire plausible parameter space, estimates tend to be more accurate for atypical parameter combinations but may have lower precision for typical parameter combinations. CONCLUSION This work highlights that estimation of model parameters using supervised ML depends strongly on the training-set distribution. We show that high precision obtained using ML may mask strong bias, and visual assessment of the parameter maps is not sufficient for evaluating the quality of the estimates.
Collapse
Affiliation(s)
- Noemi G Gyori
- Centre for Medical Image Computing, Department of Computer Science, University College London, London, UK.,Great Ormond Street Institute of Child Health, University College London, London, UK
| | - Marco Palombo
- Centre for Medical Image Computing, Department of Computer Science, University College London, London, UK
| | - Christopher A Clark
- Great Ormond Street Institute of Child Health, University College London, London, UK
| | - Hui Zhang
- Centre for Medical Image Computing, Department of Computer Science, University College London, London, UK
| | - Daniel C Alexander
- Centre for Medical Image Computing, Department of Computer Science, University College London, London, UK
| |
Collapse
|
60
|
Scalco E, Mastropietro A, Bodini A, Marzi S, Rizzo G. A Multi-Variate framework to assess reliability and discrimination power of Bayesian estimation of Intravoxel Incoherent Motion parameters. Phys Med 2021; 89:11-19. [PMID: 34343762 DOI: 10.1016/j.ejmp.2021.07.025] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/17/2021] [Revised: 06/28/2021] [Accepted: 07/19/2021] [Indexed: 02/07/2023] Open
Abstract
PURPOSE To propose a multivariate multi-step framework for a systematic assessment of the estimation reliability and discriminability of Intravoxel Incoherent Motion (IVIM) model parameters. METHODS Monte-Carlo simulations were generated on a range of SNRs and in different IVIM combinations considering: i) a dense discretization with 24 b-values; ii) a discretization with 9 b-values. A state-of-the-art Bayesian fitting method was adopted. The framework assessed: i) the best model between mono- and bi-exponential, through the BIC index; ii) the fitting accuracy; iii) the power in discriminating two different IVIM parameters distributions of estimated coefficients, using a multivariate test. Exemplificative oncologic cases were also presented. RESULTS The bi-exponential fitting was reliable for perfusion fraction higher than 5%, with high accuracy in D estimation, acceptable error for f, but high uncertainty in D*. The discrimination of two distributions is generally feasible if differences in D values (at least 0.3 x10-3 mm2/s) are present; in the case of similar D values, a minimal difference of 5% in f can be discriminated just in case of balanced sample size and dense b-values discretization, whereas the impact of D* is quite negligible. These results were also supported by clinical examples. CONCLUSIONS IVIM model is generally accurate in estimating diffusion, but uncertainties related to perfusion estimation are not negligible and compromise the discrimination power when different populations should be differentiated. The proposed framework should be adopted as interpretative guidelines to better understand when IVIM model applied on real data can provide reliable findings.
Collapse
Affiliation(s)
- E Scalco
- Institute of Biomedical Technologies, Italian National Research Council (ITB-CNR), Segrate, Italy
| | - A Mastropietro
- Institute of Biomedical Technologies, Italian National Research Council (ITB-CNR), Segrate, Italy.
| | - A Bodini
- Institute for Applied Mathematics and Information Technologies "E. Magenes", Italian National Research Council (IMATI-CNR), Milano, Italy
| | - S Marzi
- Medical Physics Laboratory, Regina Elena National Cancer Institute, Roma, Italy
| | - G Rizzo
- Institute of Biomedical Technologies, Italian National Research Council (ITB-CNR), Segrate, Italy
| |
Collapse
|
61
|
Spinner GR, Federau C, Kozerke S. Bayesian inference using hierarchical and spatial priors for intravoxel incoherent motion MR imaging in the brain: Analysis of cancer and acute stroke. Med Image Anal 2021; 73:102144. [PMID: 34261009 DOI: 10.1016/j.media.2021.102144] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2020] [Revised: 06/12/2021] [Accepted: 06/21/2021] [Indexed: 12/24/2022]
Abstract
The intravoxel incoherent motion (IVIM) model allows to map diffusion (D) and perfusion-related parameters (F and D*). Parameter estimation is, however, error-prone due to the non-linearity of the signal model, the limited signal-to-noise ratio (SNR) and the small volume fraction of perfusion in the in-vivo brain. In the present work, the performance of Bayesian inference was examined in the presence of brain pathologies characterized by hypo- and hyperperfusion. In particular, a hierarchical and a spatial prior were combined. Performance was compared relative to conventional segmented least squares regression, hierarchical prior only (non-segmented and segmented data likelihoods) and a deep learning approach. Realistic numerical brain IVIM simulations were conducted to assess errors relative to ground truth. In-vivo, data of 11 central nervous system cancer patients and 9 patients with acute stroke were acquired. The proposed method yielded reduced error in simulations for both the cancer and acute stroke scenarios compared to other methods across the whole investigated SNR range. The contrast-to-noise ratio of the proposed method was better or on par compared to the other techniques in-vivo. The proposed Bayesian approach hence improves IVIM parameter estimation in brain cancer and acute stroke.
Collapse
Affiliation(s)
- Georg Ralph Spinner
- Institute for Biomedical Engineering, University and ETH Zurich, Gloriastrasse 35, Zurich 8092, Switzerland
| | - Christian Federau
- Institute for Biomedical Engineering, University and ETH Zurich, Gloriastrasse 35, Zurich 8092, Switzerland
| | - Sebastian Kozerke
- Institute for Biomedical Engineering, University and ETH Zurich, Gloriastrasse 35, Zurich 8092, Switzerland.
| |
Collapse
|
62
|
Caan MWA, Nederveen AJ. Editorial for "Quantification of Regional Cerebral Blood Flow Using Diffusion Imaging With Phase-Contrast". J Magn Reson Imaging 2021; 54:1687-1688. [PMID: 34160119 DOI: 10.1002/jmri.27785] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2021] [Accepted: 06/04/2021] [Indexed: 11/06/2022] Open
Affiliation(s)
- Matthan W A Caan
- Biomedical Engineering and Physics, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands
| | - Aart J Nederveen
- Department of Radiology and Nuclear Medicine, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands
| |
Collapse
|
63
|
Chevallier O, Wáng YXJ, Guillen K, Pellegrinelli J, Cercueil JP, Loffroy R. Evidence of Tri-Exponential Decay for Liver Intravoxel Incoherent Motion MRI: A Review of Published Results and Limitations. Diagnostics (Basel) 2021; 11:diagnostics11020379. [PMID: 33672277 PMCID: PMC7926368 DOI: 10.3390/diagnostics11020379] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2021] [Revised: 02/14/2021] [Accepted: 02/20/2021] [Indexed: 12/11/2022] Open
Abstract
Diffusion weighted imaging (DWI) and intravoxel incoherent motion (IVIM) have been explored to assess liver tumors and diffused liver diseases. IVIM reflects the microscopic translational motions that occur in voxels in magnetic resonance (MR) DWI. In biologic tissues, molecular diffusion of water and microcirculation of blood in the capillary network can be assessed using IVIM DWI. The most commonly applied model to describe the DWI signal is a bi-exponential model, with a slow compartment of diffusion linked to pure molecular diffusion (represented by the coefficient Dslow), and a fast compartment of diffusion, related to microperfusion (represented by the coefficient Dfast). However, high variance in Dfast estimates has been consistently shown in literature for liver IVIM, restricting its application in clinical practice. This variation could be explained by the presence of another very fast compartment of diffusion in the liver. Therefore, a tri-exponential model would be more suitable to describe the DWI signal. This article reviews the published evidence of the existence of this additional very fast diffusion compartment and discusses the performance and limitations of the tri-exponential model for liver IVIM in current clinical settings.
Collapse
Affiliation(s)
- Olivier Chevallier
- Image-Guided Therapy Center, Department of Vascular and Interventional Radiology, François-Mitterrand University Hospital, 14 Rue Paul Gaffarel, BP 77908, 21079 Dijon, France; (O.C.); (K.G.); (J.P.); (J.-P.C.)
| | - Yì Xiáng J. Wáng
- Department of Imaging and Interventional Radiology, Faculty of Medicine, The Chinese University of Hong Kong, New Territories, Hong Kong, China;
| | - Kévin Guillen
- Image-Guided Therapy Center, Department of Vascular and Interventional Radiology, François-Mitterrand University Hospital, 14 Rue Paul Gaffarel, BP 77908, 21079 Dijon, France; (O.C.); (K.G.); (J.P.); (J.-P.C.)
| | - Julie Pellegrinelli
- Image-Guided Therapy Center, Department of Vascular and Interventional Radiology, François-Mitterrand University Hospital, 14 Rue Paul Gaffarel, BP 77908, 21079 Dijon, France; (O.C.); (K.G.); (J.P.); (J.-P.C.)
| | - Jean-Pierre Cercueil
- Image-Guided Therapy Center, Department of Vascular and Interventional Radiology, François-Mitterrand University Hospital, 14 Rue Paul Gaffarel, BP 77908, 21079 Dijon, France; (O.C.); (K.G.); (J.P.); (J.-P.C.)
| | - Romaric Loffroy
- Image-Guided Therapy Center, Department of Vascular and Interventional Radiology, François-Mitterrand University Hospital, 14 Rue Paul Gaffarel, BP 77908, 21079 Dijon, France; (O.C.); (K.G.); (J.P.); (J.-P.C.)
- Correspondence: ; Tel.: +33-380-293-677
| |
Collapse
|
64
|
Lee W, Kim B, Park H. Quantification of intravoxel incoherent motion with optimized b-values using deep neural network. Magn Reson Med 2021; 86:230-244. [PMID: 33594783 DOI: 10.1002/mrm.28708] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2020] [Revised: 01/12/2021] [Accepted: 01/13/2021] [Indexed: 12/17/2022]
Abstract
PURPOSE To develop a framework for quantifying intravoxel incoherent motion (IVIM) parameters, where a neural network for quantification and b-values for diffusion-weighted imaging are simultaneously optimized. METHOD A deep neural network (DNN) method is proposed for accurate quantification of IVIM parameters from multiple diffusion-weighted images. In addition, optimal b-values are selected to acquire the multiple diffusion-weighted images. The proposed framework consists of an MRI signal generation part and an IVIM parameter quantification part. Monte-Carlo (MC) simulations were performed to evaluate the accuracy of the IVIM parameter quantification and the efficacy of b-value optimization. In order to analyze the effect of noise on the optimized b-values, simulations were performed with five different noise levels. For in vivo data, diffusion images were acquired with the b-values from four b-values selection methods for five healthy volunteers at 3T MRI system. RESULTS Experiment results showed that both the optimization of b-values and the training of DNN were simultaneously performed to quantify IVIM parameters. We found that the accuracies of the perfusion coefficient (Dp ) and perfusion fraction (f) were more sensitive to b-values than the diffusion coefficient (D) was. Furthermore, when the noise level changed, the optimized b-values also changed. Therefore, noise level has to be considered when optimizing b-values for IVIM quantification. CONCLUSION The proposed scheme can simultaneously optimize b-values and train DNN to minimize quantification errors of IVIM parameters. The trained DNN can quantify IVIM parameters from the diffusion-weighted images obtained with the optimized b-values.
Collapse
Affiliation(s)
- Wonil Lee
- Department of Electrical Engineering, Korea Advanced Institute of Science and Technology, Daejeon, Republic of Korea
| | - Byungjai Kim
- Department of Electrical Engineering, Korea Advanced Institute of Science and Technology, Daejeon, Republic of Korea
| | - HyunWook Park
- Department of Electrical Engineering, Korea Advanced Institute of Science and Technology, Daejeon, Republic of Korea
| |
Collapse
|
65
|
Koopman T, Martens R, Gurney‐Champion OJ, Yaqub M, Lavini C, de Graaf P, Castelijns J, Boellaard R, Marcus JT. Repeatability of IVIM biomarkers from diffusion-weighted MRI in head and neck: Bayesian probability versus neural network. Magn Reson Med 2021; 85:3394-3402. [PMID: 33501657 PMCID: PMC7986193 DOI: 10.1002/mrm.28671] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2020] [Revised: 12/14/2020] [Accepted: 12/17/2020] [Indexed: 12/16/2022]
Abstract
Purpose The intravoxel incoherent motion (IVIM) model for DWI might provide useful biomarkers for disease management in head and neck cancer. This study compared the repeatability of three IVIM fitting methods to the conventional nonlinear least‐squares regression: Bayesian probability estimation, a recently introduced neural network approach, IVIM‐NET, and a version of the neural network modified to increase consistency, IVIM‐NETmod. Methods Ten healthy volunteers underwent two imaging sessions of the neck, two weeks apart, with two DWI acquisitions per session. Model parameters (ADC, diffusion coefficient Dt, perfusion fraction fp, and pseudo‐diffusion coefficient Dp) from each fit method were determined in the tonsils and in the pterygoid muscles. Within‐subject coefficients of variation (wCV) were calculated to assess repeatability. Training of the neural network was repeated 100 times with random initialization to investigate consistency, quantified by the coefficient of variance. Results The Bayesian and neural network approaches outperformed nonlinear regression in terms of wCV. Intersession wCV of Dt in the tonsils was 23.4% for nonlinear regression, 9.7% for Bayesian estimation, 9.4% for IVIM‐NET, and 11.2% for IVIM‐NETmod. However, results from repeated training of the neural network on the same data set showed differences in parameter estimates: The coefficient of variances over the 100 repetitions for IVIM‐NET were 15% for both Dt and fp, and 94% for Dp; for IVIM‐NETmod, these values improved to 5%, 9%, and 62%, respectively. Conclusion Repeatabilities from the Bayesian and neural network approaches are superior to that of nonlinear regression for estimating IVIM parameters in the head and neck.
Collapse
Affiliation(s)
- Thomas Koopman
- Department of Radiology and Nuclear MedicineAmsterdam UMC, Vrije Universiteit AmsterdamAmsterdamthe Netherlands
| | - Roland Martens
- Department of Radiology and Nuclear MedicineAmsterdam UMC, Vrije Universiteit AmsterdamAmsterdamthe Netherlands
| | | | - Maqsood Yaqub
- Department of Radiology and Nuclear MedicineAmsterdam UMC, Vrije Universiteit AmsterdamAmsterdamthe Netherlands
| | - Cristina Lavini
- Department of RadiologyAmsterdam UMC, University of AmsterdamAmsterdamthe Netherlands
| | - Pim de Graaf
- Department of Radiology and Nuclear MedicineAmsterdam UMC, Vrije Universiteit AmsterdamAmsterdamthe Netherlands
| | - Jonas Castelijns
- Department of Radiology and Nuclear MedicineAmsterdam UMC, Vrije Universiteit AmsterdamAmsterdamthe Netherlands
- Department of Radiologythe Netherlands Cancer Institute–Antoni van LeeuwenhoekAmsterdamthe Netherlands
| | - Ronald Boellaard
- Department of Radiology and Nuclear MedicineAmsterdam UMC, Vrije Universiteit AmsterdamAmsterdamthe Netherlands
- Department of Nuclear Medicine and Molecular ImagingUniversity Medical Center GroningenGroningenthe Netherlands
| | - J. Tim Marcus
- Department of Radiology and Nuclear MedicineAmsterdam UMC, Vrije Universiteit AmsterdamAmsterdamthe Netherlands
| |
Collapse
|
66
|
Intravoxel incoherent motion diffusion-weighted MRI for the characterization of inflammation in chronic liver disease. Eur Radiol 2020; 31:1347-1358. [PMID: 32876833 DOI: 10.1007/s00330-020-07203-y] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2020] [Revised: 06/10/2020] [Accepted: 08/18/2020] [Indexed: 12/13/2022]
Abstract
OBJECTIVE To evaluate the diagnostic performance of intravoxel incoherent motion (IVIM) diffusion-weighted imaging (DWI) for grading hepatic inflammation. METHODS In this retrospective cross-sectional dual-center study, 91 patients with chronic liver disease were recruited between September 2014 and September 2018. Patients underwent 3.0-T MRI examinations within 6 weeks from a liver biopsy. IVIM parameters, perfusion fraction (f), diffusion coefficient (D), and pseudo-diffusion coefficient (D*), were estimated using a voxel-wise nonlinear regression on DWI series (10 b-values from 0 to 800 s/mm2). The reference standard was histopathological analysis of hepatic inflammation grade, steatosis grade, and fibrosis stage. Intraclass correlation coefficients (ICC), univariate and multivariate correlation analyses, and areas under receiver operating characteristic curves (AUC) were assessed. RESULTS Parameters f, D, and D* had ICCs of 0.860, 0.839, and 0.916, respectively. Correlations of f, D, and D* with inflammation grade were ρ = - 0.70, p < 0.0001; ρ = 0.10, p = 0.35; and ρ = - 0.27, p = 0.010, respectively. When adjusting for fibrosis and steatosis, the correlation between f and inflammation (p < 0.0001) remained, and that between f and fibrosis was also significant to a lesser extent (p = 0.002). AUCs of f, D, and D* for distinguishing inflammation grades 0 vs. ≥ 1 were 0.84, 0.53, and 0.70; ≤ 1 vs. ≥ 2 were 0.88, 0.57, and 0.60; and ≤ 2 vs. 3 were 0.86, 0.54, and 0.65, respectively. CONCLUSION Perfusion fraction f strongly correlated, D very weakly correlated, and D* weakly correlated with inflammation. Among all IVIM parameters, f accurately graded inflammation and showed promise as a biomarker of hepatic inflammation. KEY POINTS • IVIM parameters derived from DWI series with 10 b-values are reproducible for liver tissue characterization. • This retrospective two-center study showed that perfusion fraction provided good diagnostic performance for distinguishing dichotomized grades of inflammation. • Fibrosis is a significant confounder on the association between inflammation and perfusion fraction.
Collapse
|
67
|
Iima M. Perfusion-driven Intravoxel Incoherent Motion (IVIM) MRI in Oncology: Applications, Challenges, and Future Trends. Magn Reson Med Sci 2020; 20:125-138. [PMID: 32536681 PMCID: PMC8203481 DOI: 10.2463/mrms.rev.2019-0124] [Citation(s) in RCA: 34] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022] Open
Abstract
Recent developments in MR hardware and software have allowed a surge of interest in intravoxel incoherent motion (IVIM) MRI in oncology. Beyond diffusion-weighted imaging (and the standard apparent diffusion coefficient mapping most commonly used clinically), IVIM provides information on tissue microcirculation without the need for contrast agents. In oncology, perfusion-driven IVIM MRI has already shown its potential for the differential diagnosis of malignant and benign tumors, as well as for detecting prognostic biomarkers and treatment monitoring. Current developments in IVIM data processing, and its use as a method of scanning patients who cannot receive contrast agents, are expected to increase further utilization. This paper reviews the current applications, challenges, and future trends of perfusion-driven IVIM in oncology.
Collapse
Affiliation(s)
- Mami Iima
- Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine.,Department of Clinical Innovative Medicine, Institute for Advancement of Clinical and Translational Science (iACT), Kyoto University Hospital
| |
Collapse
|
68
|
Lin YC, Huang HM. Denoising of multi b-value diffusion-weighted MR images using deep image prior. ACTA ACUST UNITED AC 2020; 65:105003. [DOI: 10.1088/1361-6560/ab8105] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
|
69
|
Gurney‐Champion OJ, Rauh SS, Harrington K, Oelfke U, Laun FB, Wetscherek A. Optimal acquisition scheme for flow-compensated intravoxel incoherent motion diffusion-weighted imaging in the abdomen: An accurate and precise clinically feasible protocol. Magn Reson Med 2020; 83:1003-1015. [PMID: 31566262 PMCID: PMC6899942 DOI: 10.1002/mrm.27990] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2019] [Revised: 08/14/2019] [Accepted: 08/17/2019] [Indexed: 12/16/2022]
Abstract
PURPOSE Flow-compensated (FC) diffusion-weighted MRI (DWI) for intravoxel-incoherent motion (IVIM) modeling allows for a more detailed description of tissue microvasculature than conventional IVIM. The long acquisition time of current FC-IVIM protocols, however, has prohibited clinical application. Therefore, we developed an optimized abdominal FC-IVIM acquisition with a clinically feasible scan time. METHODS Precision and accuracy of the FC-IVIM parameters were assessed by fitting the FC-IVIM model to signal decay curves, simulated for different acquisition schemes. Diffusion-weighted acquisitions were added subsequently to the protocol, where we chose the combination of b-value, diffusion time and gradient profile (FC or bipolar) that resulted in the largest improvement to its accuracy and precision. The resulting two optimized FC-IVIM protocols with 25 and 50 acquisitions (FC-IVIMopt25 and FC-IVIMopt50 ), together with a complementary acquisition consisting of 50 diffusion-weighting (FC-IVIMcomp ), were acquired in repeated abdominal free-breathing FC-IVIM imaging of seven healthy volunteers. Intersession and intrasession within-subject coefficient of variation of the FC-IVIM parameters were compared for the liver, spleen, and kidneys. RESULTS Simulations showed that the performance of FC-IVIM improved in tissue with larger perfusion fraction and signal-to-noise ratio. The scan time of the FC-IVIMopt25 and FC-IVIMopt50 protocols were 8 and 16 min. The best in vivo performance was seen in FC-IVIMopt50 . The intersession within-subject coefficients of variation of FC-IVIMopt50 were 11.6%, 16.3%, 65.5%, and 36.0% for FC-IVIM model parameters diffusivity, perfusion fraction, characteristic time and blood flow velocity, respectively. CONCLUSIONS We have optimized the FC-IVIM protocol, allowing for clinically feasible scan times (8-16 min).
Collapse
Affiliation(s)
- Oliver J. Gurney‐Champion
- Joint Department of PhysicsThe Institute of Cancer Research and The Royal Marsden NHS Foundation TrustLondonUnited Kingdom
| | - Susanne S. Rauh
- Joint Department of PhysicsThe Institute of Cancer Research and The Royal Marsden NHS Foundation TrustLondonUnited Kingdom
- Institute of RadiologyUniversity Hospital Erlangen, Friedrich‐Alexander‐Universität Erlangen‐Nürnberg (FAU)ErlangenGermany
| | - Kevin Harrington
- Targeted Therapy teamThe Institute of Cancer Research and The Royal Marsden NHS Foundation TrustLondonUnited Kingdom
| | - Uwe Oelfke
- Joint Department of PhysicsThe Institute of Cancer Research and The Royal Marsden NHS Foundation TrustLondonUnited Kingdom
| | - Frederik B. Laun
- Institute of RadiologyUniversity Hospital Erlangen, Friedrich‐Alexander‐Universität Erlangen‐Nürnberg (FAU)ErlangenGermany
| | - Andreas Wetscherek
- Joint Department of PhysicsThe Institute of Cancer Research and The Royal Marsden NHS Foundation TrustLondonUnited Kingdom
| |
Collapse
|