51
|
Hao G, Mastren T, Silvers W, Hassan G, Öz OK, Sun X. Copper-67 radioimmunotheranostics for simultaneous immunotherapy and immuno-SPECT. Sci Rep 2021; 11:3622. [PMID: 33574346 PMCID: PMC7878802 DOI: 10.1038/s41598-021-82812-1] [Citation(s) in RCA: 40] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2020] [Accepted: 01/22/2021] [Indexed: 02/01/2023] Open
Abstract
Copper-67 (t1/2 = 2.58 days) decays by β- ([Formula: see text]: 562 keV) and γ-rays (93 keV and 185 keV) rendering it with potential for both radionuclide therapy and single-photon emission computed tomography (SPECT) imaging. Prompted by the recent breakthrough of 67Cu production with high specific activity, high radionuclidic purity, and sufficient quantities, the interest in the theranostic potential of 67Cu has been rekindled. This work addresses the practicability of developing 67Cu-labeled antibodies with substantially improved quality for cancer radioimmunotheranostics. Proof of concept is demonstrated with pertuzumab, a US-FDA-approved monoclonal antibody for combination therapies of HER2-positive breast cancer. With an average number of 1.9 chelators coupled to each antibody, we achieved a two-order of magnitude increase in radiolabeling efficiency compared to literature reports. In a preclinical therapeutic study, mice (n = 4-7/group) bearing HER2+ xenografts exhibited a 67Cu-dose dependent tumor-growth inhibition from 67Cu-labeled-Pertuzumab co-administered with trastuzumab. Furthermore, greater tumor size reduction was observed with 67Cu-labeled-pertuzumab formulations of higher specific activity. The potential of SPECT imaging with 67Cu radiopharmaceuticals was tested after 67Cu-labeled-Pertuzumab administration. Impressively, all tumors were clearly visualized by SPECT imaging with 67Cu-labeled-Pertuzumab even at day 5 post injection. This work demonstrates it is practical to use 67Cu radioimmunoconjugates for cancer radioimmunotheranostics.
Collapse
Affiliation(s)
- Guiyang Hao
- Department of Radiology, University of Texas Southwestern Medical Center, Dallas, TX, 75390, USA
| | - Tara Mastren
- Department of Radiology, University of Texas Southwestern Medical Center, Dallas, TX, 75390, USA
| | - William Silvers
- Department of Radiology, University of Texas Southwestern Medical Center, Dallas, TX, 75390, USA
| | - Gedaa Hassan
- Department of Radiology, University of Texas Southwestern Medical Center, Dallas, TX, 75390, USA
| | - Orhan K Öz
- Department of Radiology, University of Texas Southwestern Medical Center, Dallas, TX, 75390, USA
| | - Xiankai Sun
- Department of Radiology, University of Texas Southwestern Medical Center, Dallas, TX, 75390, USA.
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, TX, 75390, USA.
| |
Collapse
|
52
|
Okuda K, Hasegawa D, Kamiya T, Ichikawa H, Umeda T, Ohkubo T, Miwa K. Multicenter Study of Quantitative SPECT: Reproducibility of 99mTc Quantitation Using a Conjugated-Gradient Minimization Reconstruction Algorithm. J Nucl Med Technol 2021; 49:138-142. [PMID: 33419954 DOI: 10.2967/jnmt.120.256131] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2020] [Accepted: 01/03/2021] [Indexed: 11/16/2022] Open
Abstract
This multicenter study aimed to determine the reproducibility of quantitative SPECT images reconstructed using a commercially available method of ordered-subset conjugate-gradient minimization. Methods: A common cylindric phantom containing a 100 kBq/mL concentration of 99mTc-pertechnetate solution in a volume of 7 L was scanned under standard imaging conditions at 6 institutions using the local clinical protocol of each. Interinstitutional variation among the quantitative SPECT images was evaluated using the coefficient of variation. Dose calibrator accuracy was also investigated by measuring the same lot of commercially available 99mTc vials at each institution. Results: The respective radioactivity concentrations under standard and clinical conditions ranged from 95.71 ± 0.60 (mean ± SD) to 108.35 ± 0.36 kBq/mL and from 96.78 ± 0.64 to 108.49 ± 0.11 kBq/mL, respectively. Interinstitutional variation in radioactivity concentration was 4.20%. The bias in the radioactivity concentrations in SPECT images was associated with the accuracy of the dose calibrator at each institution. Conclusion: The reproducibility of the commercially available quantitative SPECT reconstruction method is high and comparable to that of PET, for comparatively large (∼7 L), homogeneous objects.
Collapse
Affiliation(s)
- Kyohei Okuda
- Department of Clinical Radiology, Tottori University Hospital, Yonago, Japan
| | - Daisuke Hasegawa
- Department of Radiology, Okayama Saiseikai General Hospital, Okayama, Japan
| | - Takashi Kamiya
- Division of Radiology, Department of Medical Technology, Osaka University Hospital, Suita, Japan
| | - Hajime Ichikawa
- Department of Radiology, Toyohashi Municipal Hospital, Toyohashi, Japan
| | - Takuro Umeda
- Department of Nuclear Medicine, Cancer Institution Hospital of Japan Foundation for Cancer Research, Tokyo, Japan
| | - Takushi Ohkubo
- Central Division of Radiology, Toho University Omori Medical Center, Tokyo, Japan; and
| | - Kenta Miwa
- School of Health Science, International University of Health and Welfare, Ohtawara, Japan
| |
Collapse
|
53
|
Zhang YD, Dong Z, Wang SH, Yu X, Yao X, Zhou Q, Hu H, Li M, Jiménez-Mesa C, Ramirez J, Martinez FJ, Gorriz JM. Advances in multimodal data fusion in neuroimaging: Overview, challenges, and novel orientation. AN INTERNATIONAL JOURNAL ON INFORMATION FUSION 2020; 64:149-187. [PMID: 32834795 PMCID: PMC7366126 DOI: 10.1016/j.inffus.2020.07.006] [Citation(s) in RCA: 153] [Impact Index Per Article: 30.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/30/2020] [Revised: 07/06/2020] [Accepted: 07/14/2020] [Indexed: 05/13/2023]
Abstract
Multimodal fusion in neuroimaging combines data from multiple imaging modalities to overcome the fundamental limitations of individual modalities. Neuroimaging fusion can achieve higher temporal and spatial resolution, enhance contrast, correct imaging distortions, and bridge physiological and cognitive information. In this study, we analyzed over 450 references from PubMed, Google Scholar, IEEE, ScienceDirect, Web of Science, and various sources published from 1978 to 2020. We provide a review that encompasses (1) an overview of current challenges in multimodal fusion (2) the current medical applications of fusion for specific neurological diseases, (3) strengths and limitations of available imaging modalities, (4) fundamental fusion rules, (5) fusion quality assessment methods, and (6) the applications of fusion for atlas-based segmentation and quantification. Overall, multimodal fusion shows significant benefits in clinical diagnosis and neuroscience research. Widespread education and further research amongst engineers, researchers and clinicians will benefit the field of multimodal neuroimaging.
Collapse
Affiliation(s)
- Yu-Dong Zhang
- School of Informatics, University of Leicester, Leicester, LE1 7RH, Leicestershire, UK
- Department of Information Systems, Faculty of Computing and Information Technology, King Abdulaziz University, Jeddah 21589, Saudi Arabia
| | - Zhengchao Dong
- Department of Psychiatry, Columbia University, USA
- New York State Psychiatric Institute, New York, NY 10032, USA
| | - Shui-Hua Wang
- Department of Information Systems, Faculty of Computing and Information Technology, King Abdulaziz University, Jeddah 21589, Saudi Arabia
- School of Architecture Building and Civil engineering, Loughborough University, Loughborough, LE11 3TU, UK
- School of Mathematics and Actuarial Science, University of Leicester, LE1 7RH, UK
| | - Xiang Yu
- School of Informatics, University of Leicester, Leicester, LE1 7RH, Leicestershire, UK
| | - Xujing Yao
- School of Informatics, University of Leicester, Leicester, LE1 7RH, Leicestershire, UK
| | - Qinghua Zhou
- School of Informatics, University of Leicester, Leicester, LE1 7RH, Leicestershire, UK
| | - Hua Hu
- Department of Psychiatry, Columbia University, USA
- Department of Neurology, The Second Affiliated Hospital of Soochow University, China
| | - Min Li
- Department of Psychiatry, Columbia University, USA
- School of Internet of Things, Hohai University, Changzhou, China
| | - Carmen Jiménez-Mesa
- Department of Signal Theory, Networking and Communications, University of Granada, Granada, Spain
| | - Javier Ramirez
- Department of Signal Theory, Networking and Communications, University of Granada, Granada, Spain
| | - Francisco J Martinez
- Department of Signal Theory, Networking and Communications, University of Granada, Granada, Spain
| | - Juan Manuel Gorriz
- Department of Signal Theory, Networking and Communications, University of Granada, Granada, Spain
- Department of Psychiatry, University of Cambridge, Cambridge CB21TN, UK
| |
Collapse
|
54
|
Tomographic 99mTc radioactivity quantification in three-dimensional printed polymeric phantoms with bioinspired geometries. Radiat Phys Chem Oxf Engl 1993 2020. [DOI: 10.1016/j.radphyschem.2020.109130] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
|
55
|
Rohani MFM, Yonan SNM, Tagiling N, Zainon WMNW, Udin Y, Nawi NM. Standardized Uptake Value from Semiquantitative Bone Single-Photon Emission Computed Tomography/Computed Tomography in Normal Thoracic and Lumbar Vertebrae of Breast Cancer Patients. Asian Spine J 2020; 14:629-638. [PMID: 32213791 PMCID: PMC7595810 DOI: 10.31616/asj.2019.0308] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/19/2019] [Revised: 10/29/2019] [Accepted: 11/04/2019] [Indexed: 11/28/2022] Open
Abstract
STUDY DESIGN Retrospective study. PURPOSE This study aims to semiquantitatively evaluate the standardized uptake value (SUV) of 99mTc-methylene diphosphonate (MDP) radionuclide tracer in the normal vertebrae of breast cancer patients using an integrated single-photon emission computed tomography (SPECT)/computed tomography (CT) scanner. OVERVIEW OF LITERATURE Molecular imaging techniques using gamma cameras and stand-alone SPECT have traditionally been utilized to evaluate metastatic bone diseases. However, these methods lack quantitative analysis capabilities, impeding accurate uptake characterization. METHODS A total of 30 randomly selected female breast cancer patients were enrolled in this study. The SUV mean (SUVmean) and SUV maximum (SUVmax) values for 286 normal vertebrae at the thoracic and lumbar levels were calculated based on the patients' body weight (BW), body surface area (BSA), and lean body mass (LBM). Additionally, 106 degenerative joint disease (DJD) lesions of the spine were also characterized, and both their BW SUVmean and SUVmax values were obtained. A receiver operating characteristic (ROC) curve analysis was then performed to determine the cutoff value of SUV for differentiating DJD from normal vertebrae. RESULTS The mean±standard deviations for the SUVmean and SUVmax in the normal vertebrae displayed a relatively wide variability: 3.92±0.27 and 6.51±0.72 for BW, 1.05±0.07 and 1.75±0.17 for BSA, and 2.70±0.19 and 4.50±0.44 for LBM, respectively. Generally, the SUVmean had a lower coefficient of variation than the SUVmax. For DJD, the mean±standard deviation for the BW SUVmean and SUVmax was 5.26±3.24 and 7.50±4.34, respectively. Based on the ROC curve, no optimal cutoff value was found to differentiate DJD from normal vertebrae. CONCLUSIONS In this study, the SUV of 99mTc-MDP was successfully determined using SPECT/CT. This research provides an approach that could potentially aid in the clinical quantification of radionuclide uptake in normal vertebrae for the management of breast cancer patients.
Collapse
Affiliation(s)
- Mohd Fazrin Mohd Rohani
- Department of Nuclear Medicine, School of Medical Sciences, Universiti Sains Malaysia (Health Campus), Kubang Kerian, Malaysia
- Hospital Universiti Sains Malaysia, Kubang Kerian, Malaysia
| | - Siti Nurshahirah Mohd Yonan
- Medical Radiation Program, School of Health Sciences, Universiti Sains Malaysia (Health Campus), Kubang Kerian, Malaysia
| | - Nashrulhaq Tagiling
- Department of Nuclear Medicine, School of Medical Sciences, Universiti Sains Malaysia (Health Campus), Kubang Kerian, Malaysia
| | | | - Yusri Udin
- Department of Nuclear Medicine, School of Medical Sciences, Universiti Sains Malaysia (Health Campus), Kubang Kerian, Malaysia
| | - Norazlina Mat Nawi
- Department of Nuclear Medicine, School of Medical Sciences, Universiti Sains Malaysia (Health Campus), Kubang Kerian, Malaysia
- Hospital Universiti Sains Malaysia, Kubang Kerian, Malaysia
| |
Collapse
|
56
|
Ramsay SC, Cuscaden C. The current status of quantitative SPECT/CT in the assessment of transthyretin cardiac amyloidosis. J Nucl Cardiol 2020; 27:1464-1468. [PMID: 31691134 DOI: 10.1007/s12350-019-01935-1] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2019] [Accepted: 10/07/2019] [Indexed: 01/23/2023]
Abstract
Nuclear medicine bone scans differentiate ATTR cardiomyopathy (ATTR-CM) from light chain cardiac amyloidosis and other myocardial disorders, helping to make the diagnosis without biopsy. Standard bone scans are not absolutely quantitative, so are assessed by comparing the heart to other tissues. The standard visual scoring system compares heart to bone. This accurately diagnoses ATTR-CM and has been validated in a multicenter study, but has limitations. Semiquantitative techniques including heart/contralateral thorax (H/CL) and heart/whole body ratio (H/WB) improve on visual scoring but still rely on extracardiac sites as comparators. Absolute quantitation of myocardial uptake using quantitative SPECT should help overcome these shortcomings. In ATTR-CM, this technique is practical, accurately makes the diagnosis and provides information that is not identical to visual scores. However, more work needs to be done. The reproducibility in ATTR-CM must be tested. Larger studies need to be undertaken to determine whether quantitative SPECT measurements can assess prognosis, disease progression or treatment response. As ATTR-CM is relatively uncommon multicenter trials will help recruit enough subjects to answer these questions. Accurate measurement techniques are needed in ATTR-CM to enable appropriate use of proven therapy and to conduct trials of new therapeutic agents. Quantitative bone scans offer a promising avenue.
Collapse
Affiliation(s)
- Stuart C Ramsay
- Nuclear Medicine and PET, Royal Brisbane and Women's Hospital, Herston, QLD, Australia.
- School of Medicine, James Cook University, Townsville, Australia.
| | - Claire Cuscaden
- Department of Medical Imaging, Princess Alexandra Hospital, Wooloongabba, QLD, Australia
- The University of Queensland, St Lucia, QLD, Australia
| |
Collapse
|
57
|
Sahbai S, Fiz F, Taran F, Brucker S, Wallwiener D, Kupferschlaeger J, La Fougère C, Dittmann H. Influence of 99m-Tc-Nanocolloid Activity Concentration on Sentinel Lymph Node Detection in Endometrial Cancer: A Quantitative SPECT/CT Study. Diagnostics (Basel) 2020; 10:diagnostics10090700. [PMID: 32947918 PMCID: PMC7555748 DOI: 10.3390/diagnostics10090700] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2020] [Revised: 09/14/2020] [Accepted: 09/15/2020] [Indexed: 12/13/2022] Open
Abstract
This study evaluates quantitative combined single photon emission tomography/computed x-ray tomography (SPECT/CT) to assess the influence of radiotracer concentration on detection of sentinel lymph nodes (SLN) in endometrial cancer (EC). Eighty EC patients underwent pericervical 99m-Tc-nanocolloid injection followed by SPECT/CT. The subgroup of patients with failed SLN detection in SPECT/CT (n = 20) was compared to match-paired patients showing at least two SLNs. Results of intraoperative gamma probe measurements and quantitative SPECT/CT were used for comparison. In patients with detection failure, the percentage of injected dose, absolute activity, and volume of the injection site were significantly lower (30 ± 24% vs. 55 ± 19%; p = 0.01, 43 ± 36 MBq vs. 73 ± 33 MBq; p = 0.04, and 183 ± 164 mL vs. 266 ± 164 mL; p = 0.03) while mean activity concentration in liver, spleen, and bone marrow was significantly higher (p = 0.02). Activity concentration (>33 KBq/mL) and absolute activity (>73 MBq) of injection areas correlated with successful intraoperative SLN detection. In a subgroup of 19 SLNs, a correlation between SPECT/CT-derived uptake and intraoperative count rate was found (R2 = 0.8; p < 0.001). SLN detection in EC patients depended on high radiotracer activity at the cervical injection site. Quantitative SPECT/CT could predict successful intraoperative SLN detection and may help to optimize injection technique.
Collapse
Affiliation(s)
- Samine Sahbai
- Department of Nuclear Medicine and Molecular Imaging, University Hospital Tuebingen, 72076 Tuebingen, Germany; (S.S.); (F.F.); (J.K.); (C.L.F.)
| | - Francesco Fiz
- Department of Nuclear Medicine and Molecular Imaging, University Hospital Tuebingen, 72076 Tuebingen, Germany; (S.S.); (F.F.); (J.K.); (C.L.F.)
| | - Florin Taran
- Gynecology and Obstetrics, University Hospital Tuebingen, 72076 Tuebingen, Germany; (F.T.); (S.B.); (D.W.)
| | - Sara Brucker
- Gynecology and Obstetrics, University Hospital Tuebingen, 72076 Tuebingen, Germany; (F.T.); (S.B.); (D.W.)
| | - Diethelm Wallwiener
- Gynecology and Obstetrics, University Hospital Tuebingen, 72076 Tuebingen, Germany; (F.T.); (S.B.); (D.W.)
| | - Juergen Kupferschlaeger
- Department of Nuclear Medicine and Molecular Imaging, University Hospital Tuebingen, 72076 Tuebingen, Germany; (S.S.); (F.F.); (J.K.); (C.L.F.)
| | - Christian La Fougère
- Department of Nuclear Medicine and Molecular Imaging, University Hospital Tuebingen, 72076 Tuebingen, Germany; (S.S.); (F.F.); (J.K.); (C.L.F.)
- Cluster of Excellence iFIT (EXC 2180) “Image Guided and Functionally Instructed Tumor Therapies”, University of Tuebingen, 72076 Tübingen, Germany
- German Cancer Consortium (DKTK), Partner Site Tuebingen, 72076 Tuebingen, Germany
| | - Helmut Dittmann
- Department of Nuclear Medicine and Molecular Imaging, University Hospital Tuebingen, 72076 Tuebingen, Germany; (S.S.); (F.F.); (J.K.); (C.L.F.)
- Correspondence: ; Tel.: +49-07071-29-86-553
| |
Collapse
|
58
|
Schuldt A, Lehnick D, Agten CA, Beck M, Kist M, Bhure U, Del Sol Pérez Lago M, Strobel K. Performance of radiography and single-photon emission computed tomography/computed tomography in painful total hip arthroplasty and impact on arthroplasty survival. Nucl Med Commun 2020; 41:875-882. [PMID: 32796475 DOI: 10.1097/mnm.0000000000001244] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
PURPOSE To investigate the performance of radiography and single-photon emission computed tomography/computed tomography (SPECT/CT) in painful hip arthroplasty regarding loosening and arthroplasty survival. METHODS Radiography and SPECT/CT reports of 249 painful hip arthroplasties of 191 patients were reviewed. Positive imaging was defined if loosening, infection, and polyethylene wear were found, indicating the need for arthroplasty exchange. Median time from radiograph to operation or last follow-up was 41.3 months (range 0.3-118.4 months). In 67 patients, the performance of radiographs and SPECT/CT regarding loosening was compared with an intraoperative reference standard. The time point of arthroplasty exchange was compared with imaging diagnosis and evaluated with Kaplan-Meier curves. RESULTS Exchange of cup, shaft, or both was performed in 76 of 249 arthroplasties. Main diagnoses on SPECT/CT were loosening (n = 94), infection (n = 5), and polyethylene wear (n = 15). In total, 104 patients were SPECT/CT positive compared to 84 patients on radiography. Five-year survival of arthroplasties for radiograph positive and negative arthroplasties was 41.5%/83.4% and 39.3%/90.7% for SPECT/CT, respectively. Prognostic impact regarding arthroplasty exchange was highest in radiograph and SPECT/CT concordant positive patients (hazard ratio 19.7 as compared to radiograph and SPECT/CT negative patients). Sensitivity and specificity in 67 operated patients regarding shaft loosening were 59.4%/80.0% with radiography, 90.6%/68.6% with SPECT/CT (P = 0.002 for sensitivity and P = 0.29 for specificity), and for cup loosening 47.4%/89.6% with radiography and 63.2%/85.4% with SPECT/CT (P = 0.51, respectively, P = 0.63). CONCLUSION In patients with painful hip arthroplasty, positive radiography, and SPECT/CT are associated with poorer arthroplasty survival. Performance regarding loosening is slightly better with SPECT/CT.
Collapse
Affiliation(s)
- Anna Schuldt
- Radiology and Nuclear Medicine, Cantonal Hospital Lucerne
| | - Dirk Lehnick
- Biostatistics and Methodology, University of Lucerne
| | | | - Martin Beck
- Orthopaedic Surgery and Traumatology, Cantonal Hospital Lucerne, Lucerne, Switzerland
| | - Markus Kist
- Radiology and Nuclear Medicine, Cantonal Hospital Lucerne
| | - Ujwal Bhure
- Radiology and Nuclear Medicine, Cantonal Hospital Lucerne
| | | | - Klaus Strobel
- Radiology and Nuclear Medicine, Cantonal Hospital Lucerne
| |
Collapse
|
59
|
Van den Wyngaert T, Elvas F, De Schepper S, Kennedy JA, Israel O. SPECT/CT: Standing on the Shoulders of Giants, It Is Time to Reach for the Sky! J Nucl Med 2020; 61:1284-1291. [PMID: 32620702 DOI: 10.2967/jnumed.119.236943] [Citation(s) in RCA: 40] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2020] [Accepted: 05/28/2020] [Indexed: 12/11/2022] Open
Abstract
Twenty years ago, SPECT/CT became commercially available, combining the strengths of both techniques: the diagnostic sensitivity of SPECT and the anatomic detail of CT. Other benefits initially included attenuation correction of SPECT reconstructions, ultimately evolving to correction techniques that would enable absolute tracer uptake quantification. Recent developments in SPECT hardware include solid-state digital systems with higher sensitivity and resolution, using novel collimator designs based on tungsten. Similar advances in CT technology have been introduced in hybrid SPECT/CT systems, replacing low-end x-ray tubes with high-end multislice CT scanners equipped with iterative reconstruction, metal artifact reduction algorithms, and dual-energy capabilities. More recently, the design of whole-body SPECT/CT systems has taken another major leap with the introduction of a ring-shaped gantry equipped with multiple movable detectors surrounding the patient. These exciting developments have fueled efforts to develop novel SPECT radiopharmaceuticals, creating new chelators and prosthetic groups for radiolabeling. Innovative SPECT radionuclide pairs have now become available for radiolabeling with the potential for use as theranostic agents. The growth of precision medicine and the associated need for accurate radionuclide treatment dosimetry will likely drive the use of SPECT/CT in the near future. In addition, expanding clinical applications of SPECT/CT in other areas such as orthopedics offer exciting opportunities. Although it is true that the SPECT/CT ecosystem has seen several challenges during its development over the past 2 decades, it is now a feature-rich and mature tool ready for clinical prime time.
Collapse
Affiliation(s)
- Tim Van den Wyngaert
- Nuclear Medicine, Antwerp University Hospital, Edegem, Belgium .,Integrated Personalized and Precision Oncology Network, Faculty of Medicine and Health Sciences, University of Antwerp, Wilrijk, Belgium
| | - Filipe Elvas
- Nuclear Medicine, Antwerp University Hospital, Edegem, Belgium.,Integrated Personalized and Precision Oncology Network, Faculty of Medicine and Health Sciences, University of Antwerp, Wilrijk, Belgium
| | - Stijn De Schepper
- Nuclear Medicine, Antwerp University Hospital, Edegem, Belgium.,Integrated Personalized and Precision Oncology Network, Faculty of Medicine and Health Sciences, University of Antwerp, Wilrijk, Belgium
| | - John A Kennedy
- Department of Nuclear Medicine, Rambam Healthcare Campus, Haifa, Israel; and.,Rappaport School of Medicine, Israel Institute of Technology, Haifa, Israel
| | - Ora Israel
- Rappaport School of Medicine, Israel Institute of Technology, Haifa, Israel
| |
Collapse
|
60
|
Quantitative SPECT/CT for differentiating between enchondroma and grade I chondrosarcoma. Sci Rep 2020; 10:10587. [PMID: 32601314 PMCID: PMC7324365 DOI: 10.1038/s41598-020-67506-4] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2019] [Accepted: 06/09/2020] [Indexed: 11/15/2022] Open
Abstract
Although differentiation between central chondroid tumors is important, their parallelism makes it a diagnostic conundrum for clinicians and radiologists. The objective of this study was to evaluate the efficiency of quantitative single photon emission computed tomography (SPECT)/computed tomography (CT) in differentiating grade I chondrosarcomas from enchondromas. We reviewed SPECT/CT images of patients with enchondromas and grade I chondrosarcomas arising in the long bones. Volume, mean standardized uptake value (SUVmean), and maximum standardized uptake value (SUVmax) of tumors were calculated from SPECT/CT images. In addition, clinical characteristics and radiological information were assessed. Of a total of 34 patients, 14 had chondrosarcomas. Chondrosarcoma group had significantly larger volume, and higher SUVmean and SUVmax of tumors than enchondroma group. There was no significant difference in age and tumor size between two groups. Areas under the receiver-operating characteristic curve (AUCs) for tumor volume, SUVmean, and SUVmax were 0.727, 0.757, and 0.875. In pairwise analyses, SUVmax had larger AUC than SUVmean (p = 0.0216). With a cut-off value of 15.6 for SUVmax, its sensitivity and specificity were 86% and 75% for differentiating between enchondroma and grade I chondrosarcoma. Quantitative SPECT/CT is a potential method to differentiate grade I chondroarcomas from enchondromas in patients with central chondroid tumors.
Collapse
|
61
|
Hybrid (2D/3D) Dosimetry of Radiolabeled Gold Nanoparticles for Sentinel Lymph Node Detection in Patients with Breast Cancer. CONTRAST MEDIA & MOLECULAR IMAGING 2020; 2020:2728134. [PMID: 32489332 PMCID: PMC7229544 DOI: 10.1155/2020/2728134] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/27/2019] [Accepted: 12/28/2019] [Indexed: 11/17/2022]
Abstract
Previously, we reported the preparation and preclinical studies of 99mTc-labeled gold nanoparticles-mannose (99mTc-AuNP-mannose) with potential for sentinel lymph node (SLN) detection by using nuclear medicine procedures. This study aimed to evaluate the biokinetics and hybrid (2D/3D) dosimetry of 99mTc-AuNP-mannose in five patients with breast cancer under a sentinel lymph node detection protocol. Anterior and posterior whole-body planar images (2D, at 0.5, 2, 6, and 24 h) and single-photon emission computed tomography (3D at 6.5 h)/computed tomography (SPECT/CT) images were acquired after 99mTc-AuNP-mannose administration (37 MBq). Through a hybrid quantification method, activity in tissues of interest at the different acquisition times was determined and integrated over time to obtain the total nuclear transformations (N), as well as the mean residence time, in each tissue. N values and the OLINDA code were used for estimating the internal radiation absorbed doses. Results demonstrated that 99mTc-AuNP-mannose successfully accumulates and remains up to 24 h in the sentinel lymph node without detectable migration to other lymph nodes and no side effects on patients. Negligible absorption of the radiolabeled nanoparticles into the circulatory system was observed, from which the radio-nanosystem is rapidly eliminated by kidneys. Hybrid (2D/3D) dosimetry evaluations showed equivalent doses to SLN, breast, and kidneys of 172.34, 5.32, and 0.08 mSv/37 MBq, respectively, with an effective dose of 2.05E - 03 mSv/MBq. The mean effective residence time in SLN was 0.92 h. This preliminary study indicates that the use of 99mTc-AuNP-mannose for successful SLN detection in patients is safe, producing an effective dose at the level recommended for diagnostic studies (<10 mSv).
Collapse
|
62
|
Dittmann H, Kaltenbach S, Weissinger M, Fiz F, Martus P, Pritzkow M, Kupferschlaeger J, la Fougère C. The Prognostic Value of Quantitative Bone SPECT/CT Before 223Ra Treatment in Metastatic Castration-Resistant Prostate Cancer. J Nucl Med 2020; 62:48-54. [PMID: 32444369 DOI: 10.2967/jnumed.119.240408] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2019] [Accepted: 04/22/2020] [Indexed: 12/31/2022] Open
Abstract
Radiolabeled bisphosphonates such as 99mTc-3,3-diphosphono-1,2-propanodicarboxylic acid (99mTc-DPD) typically show intense uptake in skeletal metastases from metastatic castration-resistant prostate cancer (mCRPC). Extensive bone involvement is regarded as a risk factor for mCRPC patients treated with 223Ra-dichloride (223Ra). The aim of this study was to quantify 99mTc-DPD uptake by means of SPECT/CT before 223Ra and compare the results with the feasibility of treatment and overall survival (OS). Methods: Sixty consecutive mCRPC patients were prospectively included in this study. SPECT/CT of the central skeleton covering the skull to the mid-femoral level was performed before the first cycle of 223Ra. The bone compartment was defined by means of low-dose CT. Emission data were corrected for scatter, attenuation, and decay supplemented by resolution recovery using dedicated software. The Kaplan-Meier estimator, U test, and Cox regression analysis were used for statistics. Results: Total 99mTc-DPD uptake of the central skeleton varied between 11% and 56% of injected dose (%ID) or between 1.8 and 10.5 %ID/1,000 mL of bone volume (%ID/L). SUVmean ranged from 1.9 to 7.4, whereas the SUVmax range was 18-248. Patients unable to complete 223Ra treatment because of progression and/or cytopenia (n = 23) showed significantly higher uptake (31.9 vs. 25.4 %ID and 6.0 vs. 4.7 %ID/L; P < 0.02). OS after 223Ra (median, 15.2 mo) was reduced to 7.3 mo in cases of skeletal uptake that was 26 %ID or higher, as compared with 30.8 mo if lower than 26 %ID (P = 0.008). Similar results were obtained for %ID/L and SUVmean SUVmax did not correlate with survival. %ID/L was identified as an independent prognostic factor for OS (hazard ratio, 1.381 per unit), along with number of previous treatment lines. Conclusion: Quantitative SPECT/CT of bone scans performed at baseline is prognostic for survival in mCRPC patients treated with 223Ra.
Collapse
Affiliation(s)
- Helmut Dittmann
- Department of Nuclear Medicine and Clinical Molecular Imaging, University Hospital Tuebingen, Tuebingen, Germany
| | - Sabine Kaltenbach
- Department of Nuclear Medicine and Clinical Molecular Imaging, University Hospital Tuebingen, Tuebingen, Germany
| | - Matthias Weissinger
- Department of Nuclear Medicine and Clinical Molecular Imaging, University Hospital Tuebingen, Tuebingen, Germany
| | - Francesco Fiz
- Department of Nuclear Medicine and Clinical Molecular Imaging, University Hospital Tuebingen, Tuebingen, Germany
| | - Peter Martus
- Institute for Clinical Epidemiology and Applied Biometry, University of Tuebingen, Tuebingen, Germany; and
| | - Maren Pritzkow
- Department of Nuclear Medicine and Clinical Molecular Imaging, University Hospital Tuebingen, Tuebingen, Germany
| | - Juergen Kupferschlaeger
- Department of Nuclear Medicine and Clinical Molecular Imaging, University Hospital Tuebingen, Tuebingen, Germany
| | - Christian la Fougère
- Department of Nuclear Medicine and Clinical Molecular Imaging, University Hospital Tuebingen, Tuebingen, Germany.,iFIT Cluster of Excellence, University of Tuebingen, Tuebingen, Germany
| |
Collapse
|
63
|
Peters SMB, Meyer Viol SL, van der Werf NR, de Jong N, van Velden FHP, Meeuwis A, Konijnenberg MW, Gotthardt M, de Jong HWAM, Segbers M. Variability in lutetium-177 SPECT quantification between different state-of-the-art SPECT/CT systems. EJNMMI Phys 2020; 7:9. [PMID: 32048097 PMCID: PMC7013023 DOI: 10.1186/s40658-020-0278-3] [Citation(s) in RCA: 41] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2019] [Accepted: 01/27/2020] [Indexed: 12/16/2022] Open
Abstract
BACKGROUND Quantitative SPECT imaging in targeted radionuclide therapy with lutetium-177 holds great potential for individualized treatment based on dose assessment. The establishment of dose-effect relations requires a standardized method for SPECT quantification. The purpose of this multi-center study is to evaluate quantitative accuracy and inter-system variations of different SPECT/CT systems with corresponding commercially available quantitative reconstruction algorithms. This is an important step towards a vendor-independent standard for quantitative lutetium-177 SPECT. METHODS Four state-of-the-art SPECT/CT systems were included: Discovery™ NM/CT 670Pro (GE Healthcare), Symbia Intevo™, and two Symbia™ T16 (Siemens Healthineers). Quantitative accuracy and inter-system variations were evaluated by repeatedly scanning a cylindrical phantom with 6 spherical inserts (0.5 - 113 ml). A sphere-to-background activity concentration ratio of 10:1 was used. Acquisition settings were standardized: medium energy collimator, body contour trajectory, photon energy window of 208 keV (± 10%), adjacent 20% lower scatter window, 2 × 64 projections, 128 × 128 matrix size, and 40 s projection time. Reconstructions were performed using GE Evolution with Q.Metrix™, Siemens xSPECT Quant™, Siemens Broad Quantification™ or Siemens Flash3D™ algorithms using vendor recommended settings. In addition, projection data were reconstructed using Hermes SUV SPECT™ with standardized reconstruction settings to obtain a vendor-neutral quantitative reconstruction for all systems. Volumes of interest (VOI) for the spheres were obtained by applying a 50% threshold of the sphere maximum voxel value corrected for background activity. For each sphere, the mean and maximum recovery coefficient (RCmean and RCmax) of three repeated measurements was calculated, defined as the imaged activity concentration divided by the actual activity concentration. Inter-system variations were defined as the range of RC over all systems. RESULTS RC decreased with decreasing sphere volume. Inter-system variations with vendor-specific reconstructions were between 0.06 and 0.41 for RCmean depending on sphere size (maximum 118% quantification difference), and improved to 0.02-0.19 with vendor-neutral reconstructions (maximum 38% quantification difference). CONCLUSION This study shows that eliminating sources of possible variation drastically reduces inter-system variation in quantification. This means that absolute SPECT quantification for 177Lu is feasible in a multi-center and multi-vendor setting; however, close agreement between vendors and sites is key for multi-center dosimetry and quantitative biomarker studies.
Collapse
Affiliation(s)
- Steffie M B Peters
- Department of Radiology and Nuclear Medicine, Department of Radiology and Nuclear Medicine, Radboud University Medical Center, P.O. Box 9101, 6500, HB, Nijmegen, The Netherlands.
| | - Sebastiaan L Meyer Viol
- Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Niels R van der Werf
- Department of Radiology and Nuclear Medicine, Erasmus MC, Rotterdam, The Netherlands
| | - Nick de Jong
- Department of Radiology, Section of Medical Technology, Leiden University Medical Center, Leiden, The Netherlands
| | - Floris H P van Velden
- Department of Radiology, Section of Medical Technology, Leiden University Medical Center, Leiden, The Netherlands
| | - Antoi Meeuwis
- Department of Radiology and Nuclear Medicine, Department of Radiology and Nuclear Medicine, Radboud University Medical Center, P.O. Box 9101, 6500, HB, Nijmegen, The Netherlands
| | - Mark W Konijnenberg
- Department of Radiology and Nuclear Medicine, Erasmus MC, Rotterdam, The Netherlands
| | - Martin Gotthardt
- Department of Radiology and Nuclear Medicine, Department of Radiology and Nuclear Medicine, Radboud University Medical Center, P.O. Box 9101, 6500, HB, Nijmegen, The Netherlands
| | - Hugo W A M de Jong
- Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Marcel Segbers
- Department of Radiology and Nuclear Medicine, Erasmus MC, Rotterdam, The Netherlands
| |
Collapse
|
64
|
Abstract
The continuous development of SPECT over the past 50 years has led to improved image quality and increased diagnostic confidence. The most influential developments include the realization of hybrid SPECT/CT devices, as well as the implementation of attenuation correction and iterative image reconstruction techniques. These developments have led to a preference for SPECT/CT devices over SPECT-only systems and to the widespread adoption of the former, strengthening the role of SPECT/CT as the workhorse of Nuclear Medicine imaging. New trends in the ongoing development of SPECT/CT are diverse. For example, whole-body SPECT/CT images, consisting of acquisitions from multiple consecutive bed positions in the manner of PET/CT, are increasingly performed. Additionally, in recent years, some interesting approaches in detector technology have found their way into commercial products. For example, some SPECT cameras dedicated to specific organs employ semiconductor detectors made of cadmium telluride or cadmium zinc telluride, which have been shown to increase the obtainable image quality by offering a higher sensitivity and energy resolution. However, the advent of quantitative SPECT/CT which, like PET, can quantify the amount of tracer in terms of Bq/mL or as a standardized uptake value could be regarded as most important development. It is a major innovation that will lead to increased diagnostic accuracy and confidence, especially in longitudinal studies and in the monitoring of treatment response. The current work comprises two main aspects. At first, physical and technical fundamentals of SPECT image formation are described and necessary prerequisites of quantitative SPECT/CT are reviewed. Additionally, the typically achievable quantitative accuracy based on reports from the literature is given. Second, an extensive list of studies reporting on clinical applications of quantitative SPECT/CT is provided and reviewed.
Collapse
Affiliation(s)
- Philipp Ritt
- Clinic of Nuclear Medicine, University Hospital Erlangen, Ulmenweg 18, 91054, Erlangen, Germany.
| | - Torsten Kuwert
- Clinic of Nuclear Medicine, University Hospital Erlangen, Ulmenweg 18, 91054, Erlangen, Germany
| |
Collapse
|
65
|
Pérez-Medina C, Teunissen AJ, Kluza E, Mulder WJ, van der Meel R. Nuclear imaging approaches facilitating nanomedicine translation. Adv Drug Deliv Rev 2020; 154-155:123-141. [PMID: 32721459 DOI: 10.1016/j.addr.2020.07.017] [Citation(s) in RCA: 48] [Impact Index Per Article: 9.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2020] [Revised: 07/08/2020] [Accepted: 07/17/2020] [Indexed: 02/07/2023]
Abstract
Nanomedicine approaches can effectively modulate the biodistribution and bioavailability of therapeutic agents, improving their therapeutic index. However, despite the ever-increasing amount of literature reporting on preclinical nanomedicine, the number of nanotherapeutics receiving FDA approval remains relatively low. Several barriers exist that hamper the effective preclinical evaluation and clinical translation of nanotherapeutics. Key barriers include insufficient understanding of nanomedicines' in vivo behavior, inadequate translation from murine models to larger animals, and a lack of patient stratification strategies. Integrating quantitative non-invasive imaging techniques in nanomedicine development offers attractive possibilities to address these issues. Among the available imaging techniques, nuclear imaging by positron emission tomography (PET) and single-photon emission computed tomography (SPECT) are highly attractive in this context owing to their quantitative nature and uncontested sensitivity. In basic and translational research, nuclear imaging techniques can provide critical quantitative information about pharmacokinetic parameters, biodistribution profiles or target site accumulation of nanocarriers and their associated payload. During clinical evaluation, nuclear imaging can be used to select patients amenable to nanomedicine treatment. Here, we review how nuclear imaging-based approaches are increasingly being integrated into nanomedicine development and discuss future developments that will accelerate their clinical translation.
Collapse
|
66
|
Ding L, Lyu Z, Tintaru A, Laurini E, Marson D, Louis B, Bouhlel A, Balasse L, Fernandez S, Garrigue P, Mas E, Giorgio S, Pricl S, Guillet B, Peng L. A self-assembling amphiphilic dendrimer nanotracer for SPECT imaging. Chem Commun (Camb) 2020; 56:301-304. [DOI: 10.1039/c9cc07750b] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
An amphiphilic dendrimer bearing SPECT imaging reporters is self-assembled into supramolecular nanomicelles for effective tumor imaging.
Collapse
Affiliation(s)
- Ling Ding
- Aix Marseille Univ
- CNRS
- Centre Interdisciplinaire de Nanoscience de Marseille (UMR 7325)
- Equipe Labellisée Ligue Contre le Cancer
- Marseille
| | - Zhenbin Lyu
- Aix Marseille Univ
- CNRS
- Centre Interdisciplinaire de Nanoscience de Marseille (UMR 7325)
- Equipe Labellisée Ligue Contre le Cancer
- Marseille
| | - Aura Tintaru
- Aix Marseille Univ
- CNRS
- Institut de Chimie Radicalaire (UMR7273)
- Marseille
- France
| | - Erik Laurini
- Molecular Biology and Nanotechnology Laboratory (MolBNL@UniTS)
- DEA
- University of Trieste
- Trieste
- Italy
| | - Domenico Marson
- Molecular Biology and Nanotechnology Laboratory (MolBNL@UniTS)
- DEA
- University of Trieste
- Trieste
- Italy
| | | | | | | | | | | | - Eric Mas
- Aix Marseille Univ
- CNRS
- INSERM
- Institut Paoli-Calmettes
- Centre de Recherche en Cancérologie de Marseille (CRCM)
| | - Suzanne Giorgio
- Aix Marseille Univ
- CNRS
- Centre Interdisciplinaire de Nanoscience de Marseille (UMR 7325)
- Equipe Labellisée Ligue Contre le Cancer
- Marseille
| | - Sabrina Pricl
- Molecular Biology and Nanotechnology Laboratory (MolBNL@UniTS)
- DEA
- University of Trieste
- Trieste
- Italy
| | | | - Ling Peng
- Aix Marseille Univ
- CNRS
- Centre Interdisciplinaire de Nanoscience de Marseille (UMR 7325)
- Equipe Labellisée Ligue Contre le Cancer
- Marseille
| |
Collapse
|
67
|
Brady SL, Shulkin BL. Analysis of quantitative [I-123] mIBG SPECT/CT in a phantom and in patients with neuroblastoma. EJNMMI Phys 2019; 6:31. [PMID: 31889238 PMCID: PMC6937351 DOI: 10.1186/s40658-019-0267-6] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2019] [Accepted: 12/02/2019] [Indexed: 11/13/2022] Open
Abstract
Purpose To determine the accuracy of quantitative SPECT, intersystem and interpatient standardized uptake value (SUV) calculation consistency for a manufacturer-independent quantitative SPECT/CT reconstruction algorithm, and the range of SUVs of normal and neoplastic tissue. Methods A NEMA body phantom with 6 spheres (ranging 10–37 mm) was filled with a known activity-to-volume ratio and used to determine the contrast recovery coefficient (CRC) for each visible sphere, and the measured SUV accuracy of those spheres and background water solution. One hundred eleven 123I-metaiodobenzylguanidine ([I-123] mIBG) SPECT/CT examinations from 43 patients were reconstructed using SUV SPECT® (HERMES Medical Solutions Inc.); 42 examinations were acquired using a GE Infinia Hawkeye 4 SPECT/CT, and 69 were acquired on a Siemens Symbia Intevo SPECT/CT. Inter scanner SUV analysis of 9 regions of normal [I-123] mIBG tissue uptake was conducted. Intrapatient mean SUV variability was calculated by measuring normal liver uptake within patients scanned on both cameras. The intensity of uptake by neoplastic tissue in the images was quantified using maximum SUV and, if present, compared over time. Results The phantom results of the visible spheres and background resulted in accuracy calculations better than 5–10% with CRC correction. Interscanner SUV variability showed no statistical difference (average p value 0.559; range 0.066–1.0) among the 9 normal tissues analyzed. Intrapatient liver mean SUV varied ≤ 16% as calculated for 28 patients (87 examinations) studied on both scanners. In one patient, a thoracic tumor evaluated over 10 time points (18 months) underwent a 74% (3.1/12.0) reduction in maximum SUV with treatment. Conclusion The results demonstrate quantitative accuracy to better than 10%, and both consistent SUV calculation between 2 different SPECT/CT scanners for 9 tissues, and low intrapatient measurement variability for quantitative SPECT/CT analysis in a pediatric population with neuroblastoma. Quantitative SPECT/CT offers the opportunity for objective analysis of tumor response using [I-123] mIBG by normalizing the uptake to injected dose and patient weight, as is done for PET.
Collapse
Affiliation(s)
- Samuel L Brady
- Department of Radiology, Cincinnati Children's Hospital Medical Center, University of Cincinnati, Cincinnati, OH, 45229, USA
| | - Barry L Shulkin
- Department of Diagnostic Imaging MS 220, St. Jude Children's Research Hospital, 262 Danny Thomas Place, Memphis, TN, 38105-3678, USA.
| |
Collapse
|
68
|
Peters SMB, van der Werf NR, Segbers M, van Velden FHP, Wierts R, Blokland KJAK, Konijnenberg MW, Lazarenko SV, Visser EP, Gotthardt M. Towards standardization of absolute SPECT/CT quantification: a multi-center and multi-vendor phantom study. EJNMMI Phys 2019; 6:29. [PMID: 31879813 PMCID: PMC6933042 DOI: 10.1186/s40658-019-0268-5] [Citation(s) in RCA: 57] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2019] [Accepted: 12/05/2019] [Indexed: 11/29/2022] Open
Abstract
Abstract Absolute quantification of radiotracer distribution using SPECT/CT imaging is of great importance for dosimetry aimed at personalized radionuclide precision treatment. However, its accuracy depends on many factors. Using phantom measurements, this multi-vendor and multi-center study evaluates the quantitative accuracy and inter-system variability of various SPECT/CT systems as well as the effect of patient size, processing software and reconstruction algorithms on recovery coefficients (RC). Methods Five SPECT/CT systems were included: Discovery™ NM/CT 670 Pro (GE Healthcare), Precedence™ 6 (Philips Healthcare), Symbia Intevo™, and Symbia™ T16 (twice) (Siemens Healthineers). Three phantoms were used based on the NEMA IEC body phantom without lung insert simulating body mass indexes (BMI) of 25, 28, and 47 kg/m2. Six spheres (0.5–26.5 mL) and background were filled with 0.1 and 0.01 MBq/mL 99mTc-pertechnetate, respectively. Volumes of interest (VOI) of spheres were obtained by a region growing technique using a 50% threshold of the maximum voxel value corrected for background activity. RC, defined as imaged activity concentration divided by actual activity concentration, were determined for maximum (RCmax) and mean voxel value (RCmean) in the VOI for each sphere diameter. Inter-system variability was expressed as median absolute deviation (MAD) of RC. Acquisition settings were standardized. Images were reconstructed using vendor-specific 3D iterative reconstruction algorithms with institute-specific settings used in clinical practice and processed using a standardized, in-house developed processing tool based on the SimpleITK framework. Additionally, all data were reconstructed with a vendor-neutral reconstruction algorithm (Hybrid Recon™; Hermes Medical Solutions). Results RC decreased with decreasing sphere diameter for each system. Inter-system variability (MAD) was 16 and 17% for RCmean and RCmax, respectively. Standardized reconstruction decreased this variability to 4 and 5%. High BMI hampers quantification of small lesions (< 10 ml). Conclusion Absolute SPECT quantification in a multi-center and multi-vendor setting is feasible, especially when reconstruction protocols are standardized, paving the way for a standard for absolute quantitative SPECT.
Collapse
Affiliation(s)
- Steffie M B Peters
- Department of Radiology and Nuclear Medicine, Radboudumc, P.O. Box 9101, 6500 HB, Nijmegen, The Netherlands.
| | - Niels R van der Werf
- Department of Radiology and Nuclear Medicine, Erasmus MC, Rotterdam, The Netherlands.,Department of Medical Physics, Albert Schweitzer Hospital, Dordrecht, The Netherlands
| | - Marcel Segbers
- Department of Radiology and Nuclear Medicine, Erasmus MC, Rotterdam, The Netherlands
| | - Floris H P van Velden
- Department of Radiology, Section of Medical Physics, Leiden University Medical Center, Leiden, The Netherlands
| | - Roel Wierts
- Department of Radiology and Nuclear Medicine, Maastricht UMC+, Maastricht, The Netherlands
| | - Koos J A K Blokland
- Department of Radiology, Section of Medical Physics, Leiden University Medical Center, Leiden, The Netherlands
| | - Mark W Konijnenberg
- Department of Radiology and Nuclear Medicine, Erasmus MC, Rotterdam, The Netherlands
| | - Sergiy V Lazarenko
- Department of Nuclear Medicine, Noordwest Ziekenhuisgroep, Alkmaar, The Netherlands
| | - Eric P Visser
- Department of Radiology and Nuclear Medicine, Radboudumc, P.O. Box 9101, 6500 HB, Nijmegen, The Netherlands
| | - Martin Gotthardt
- Department of Radiology and Nuclear Medicine, Radboudumc, P.O. Box 9101, 6500 HB, Nijmegen, The Netherlands
| |
Collapse
|
69
|
Gregory RA, Murray I, Gear J, Leek F, Chittenden S, Fenwick A, Wevrett J, Scuffham J, Tipping J, Murby B, Jeans S, Stuffins M, Michopoulou S, Guy M, Morgan D, Hallam A, Hall D, Polydor H, Brown C, Gillen G, Dickson N, Brown S, Wadsley J, Flux G. Standardised quantitative radioiodine SPECT/CT Imaging for multicentre dosimetry trials in molecular radiotherapy. Phys Med Biol 2019; 64:245013. [PMID: 31766032 DOI: 10.1088/1361-6560/ab5b6c] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
The SEL-I-METRY trial (EudraCT No 2015-002269-47) is the first multicentre trial to investigate the role of 123I and 131I SPECT/CT-based tumour dosimetry to predict response to radioiodine therapy. Standardised dosimetry methodology is essential to provide a robust evidence-base for absorbed dose-response thresholds for molecular radiotherapy (MRT). In this paper a practical standardised protocol is used to establish the first network of centres with consistent methods of radioiodine activity quantification. Nine SPECT/CT systems at eight centres were set-up for quantitative radioiodine imaging. The dead-time of the systems was characterised for up to 2.8 GBq 131I. Volume dependent calibration factors were measured on centrally reconstructed images of 123I and 131I in six (0.8-196 ml) cylinders. Validation of image quantification using these calibration factors was performed on three systems, by imaging a 3D-printed phantom mimicking a patient's activity distribution. The percentage differences between the activities measured in the SPECT/CT image and those measured by the radionuclide calibrator were calculated. Additionally uncertainties on the SPECT/CT-based activities were calculated to indicate the limit on the quantitative accuracy of this method. For systems set-up to image high 131I count rates, the count rate versus activity did not peak below 2.8 GBq and fit a non-paralysable model. The dead-times and volume-dependent calibration factors were comparable between systems of the same model and crystal thickness. Therefore a global calibration curve could be fitted to each. The errors on the validation phantom activities' were comparable to the measurement uncertainties derived from uncertainty analysis, at 10% and 16% on average for 123I and 131I respectively in a 5 cm sphere. In conclusion, the dead-time and calibration factors varied between centres, with different models of system. However, global calibration factors may be applied to the same system model with the same crystal thickness, to simplify set-up of future multi-centre MRT studies.
Collapse
|
70
|
Bone SPECT/CT of the Foot and Ankle: Potential Clinical Application for Chronic Foot Pain. Nucl Med Mol Imaging 2019; 54:1-8. [PMID: 32206126 DOI: 10.1007/s13139-019-00627-5] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2019] [Revised: 11/15/2019] [Accepted: 11/26/2019] [Indexed: 12/15/2022] Open
Abstract
Diseases of the foot and ankle are common but relatively difficult to diagnose because of the complexity of the anatomy and the frequent occurrence of multiple diseases at the same time. For these reasons, management of chronic foot pain is often clinically challenging. MRI is the imaging modality of choice in many types of diseases causing chronic foot pain, due to high resolution and excellent soft tissue contrast. However, in the postoperative state, the use of MRI can be limited by artifact from metallic devices, and it may be difficult to confirm whether the pathology detected on the MRI is the actual cause of the pain. As bone scintigraphy provides metabolic information, it can help to find the origin of pain, and SPECT/CT can further improve the specificity by adding anatomical information. In daily clinical practice for management of foot and ankle pathologies, the use of bone SPECT/CT is gradually increasing. However, there has been limited evidence of usefulness of SPECT/CT in evaluating chronic foot pain. In this review article, the potential application of bone SPECT/CT for chronic foot pain is illustrated, and the role of SPECT/CT in the management of the foot and ankle diseases in clinical practice is described.
Collapse
|
71
|
A guide to 90Y radioembolization and its dosimetry. Phys Med 2019; 68:132-145. [DOI: 10.1016/j.ejmp.2019.09.236] [Citation(s) in RCA: 32] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/05/2019] [Revised: 09/15/2019] [Accepted: 09/17/2019] [Indexed: 01/14/2023] Open
|
72
|
Huang K, Feng Y, Liu D, Liang W, Li L. Quantification evaluation of 99mTc-MDP concentration in the lumbar spine with SPECT/CT: compare with bone mineral density. Ann Nucl Med 2019; 34:136-143. [PMID: 31768820 DOI: 10.1007/s12149-019-01425-x] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2019] [Accepted: 11/18/2019] [Indexed: 12/26/2022]
Abstract
BACKGROUND Despite recent technological advances allowing for quantitative single-photon emission computed tomography (SPECT), quantitative SPECT has not been widely used in the clinical practice of osteoporosis. The aim of this study is to evaluate the feasibility of quantitative bone SPECT/CT for measuring lumbar standard uptake value (SUV) in patients with different bone-mineral density (BMD), and investigate the correlation between SUV measured with 99mTc-methylene diphosphonate (MDP) SPECT/CT and BMD assessment by dual-energy X-ray absorptiometry (DXA). METHODS A retrospective analysis of 62 cases 99mTc-MDP whole-body bone imaging and local lumbar SPECT/CT tomography were performed. According to the results of dual-energy X-ray bone density examination, they were divided into normal group, osteopenic group, and osteoporosis group. The raw SPECT data were reconstructed using flash3D which includes attenuation correction, scatter compensation, and collimator resolution recovery, SPECT images from this algorithm were calibrated for SUV analysis. Comparing difference of lumbar SUV in different BMD subjects, and investigating the correlation between lumbar SUV and BMD. Data were analyzed by one-way ANOVA and Pearson regression analysis using SPSS 17.0 software. RESULTS The maximum SUV (SUVmax) and mean SUV (SUVmean) of L1-L4 vertebral in 62 subjects were 7.39 ± 1.84 and 4.90 ± 1.27, respectively. The average BMD was 0.85 ± 0.15 (g/cm2), and the average CT value was 145.88 ± 53.99 (HU). The SUVmax, SUVmean, BMD, and CT values of the lumbar spine were statistically significantly different among the three groups (F = 24.089, 30.501, 94.847, 30.241, all p < 0.001), and the osteopenic group was significantly lower than the normal group (all p < 0.001), the osteoporosis group was significantly lower than the normal group and the osteopenic group (all p < 0.001). Lumbar SUVmax, SUVmean, and BMD were significantly negatively correlated with age (r = - 0.328 to - 0.442, all p < 0.05), and positively correlated with body weight and CT value (r = 0.299-0.737, all p < 0.05), but no significant correlation with height (r = 0.006-0.175, all p > 0.05). Lumbar SUVmax and SUVmean increased significantly with the increase of BMD (r = 0.638, 0.632, p < 0.001). CONCLUSION The SUV of lumbar spine in 99mTc-MDP bone SPECT/CT was significantly different among subjects with different BMD, and the SUV was positively correlated with BMD. These findings justify that quantitative bone SPECT/CT is an applicable tool for clinical quantification of bone metabolism in osteoporosis patients.
Collapse
Affiliation(s)
- Kemin Huang
- Department of Nuclear Medicine, The First People's Hospital of Foshan, Foshan, 528000, Guangdong, China
| | - Yanlin Feng
- Department of Nuclear Medicine, The First People's Hospital of Foshan, Foshan, 528000, Guangdong, China.
| | - Dejun Liu
- Department of Nuclear Medicine, The First People's Hospital of Foshan, Foshan, 528000, Guangdong, China
| | - Weitang Liang
- Department of Nuclear Medicine, The First People's Hospital of Foshan, Foshan, 528000, Guangdong, China
| | - Lin Li
- Department of Nuclear Medicine, The First People's Hospital of Foshan, Foshan, 528000, Guangdong, China
| |
Collapse
|
73
|
Weber M, Binse I, Nagarajah J, Bockisch A, Herrmann K, Jentzen W. The role of 124I PET/CT lesion dosimetry in differentiated thyroid cancer. THE QUARTERLY JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING : OFFICIAL PUBLICATION OF THE ITALIAN ASSOCIATION OF NUCLEAR MEDICINE (AIMN) [AND] THE INTERNATIONAL ASSOCIATION OF RADIOPHARMACOLOGY (IAR), [AND] SECTION OF THE SOCIETY OF RADIOPHARMACEUTICAL CHEMISTRY AND BIOLOGY 2019; 63:235-252. [DOI: 10.23736/s1824-4785.19.03201-1] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
|
74
|
99mTc-Labeled LyP-1 for SPECT Imaging of Triple Negative Breast Cancer. CONTRAST MEDIA & MOLECULAR IMAGING 2019; 2019:9502712. [PMID: 31598115 PMCID: PMC6778934 DOI: 10.1155/2019/9502712] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/15/2019] [Revised: 07/30/2019] [Accepted: 08/22/2019] [Indexed: 12/14/2022]
Abstract
Triple negative breast cancer (TNBC), the most aggressive breast cancer type, is associated with high mortality and recurrence rates. An active-targeted strategy based on homing peptides is an effective approach to diagnose and treat cancer as it can deliver imaging agents or therapeutic drugs into desired tissues and accumulate less into off-target tissues. As a homing peptide, LyP-1 has shown properties of targeting, internalization, and proapoptosis to TNBC. In the study, we designed a Technetium-99m- (99mTc-) labeled LyP-1 and investigated its feasibility for targeted single-positron emission computed tomography (SPECT) imaging of TNBC. The results showed that the LyP-1 peptide had acceptable biocompatibility in the studied concentration range and could specifically bind to TNBC cells in vitro. 99mTc-labeled LyP-1 showed high radiochemical purity and stability and could be used as a probe for targeted SPECT imaging of TNBC cells in vitro and in a TNBC tumor-bearing mouse model. Our findings indicate that this active-targeted strategy has great potential to be developed into a new imaging tool for TNBC diagnosis.
Collapse
|
75
|
De Schepper S, Ritt P, Van den Wyngaert T, Kuwert T. Quantitative radionuclide imaging of bone metastases. THE QUARTERLY JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING : OFFICIAL PUBLICATION OF THE ITALIAN ASSOCIATION OF NUCLEAR MEDICINE (AIMN) [AND] THE INTERNATIONAL ASSOCIATION OF RADIOPHARMACOLOGY (IAR), [AND] SECTION OF THE SOCIETY OF RADIOPHARMACEUTICAL CHEMISTRY AND BIOLOGY 2019; 63:129-135. [DOI: 10.23736/s1824-4785.19.03204-7] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
76
|
Taïeb D, Hicks RJ, Hindié E, Guillet BA, Avram A, Ghedini P, Timmers HJ, Scott AT, Elojeimy S, Rubello D, Virgolini IJ, Fanti S, Balogova S, Pandit-Taskar N, Pacak K. European Association of Nuclear Medicine Practice Guideline/Society of Nuclear Medicine and Molecular Imaging Procedure Standard 2019 for radionuclide imaging of phaeochromocytoma and paraganglioma. Eur J Nucl Med Mol Imaging 2019; 46:2112-2137. [PMID: 31254038 PMCID: PMC7446938 DOI: 10.1007/s00259-019-04398-1] [Citation(s) in RCA: 236] [Impact Index Per Article: 39.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2019] [Accepted: 06/10/2019] [Indexed: 01/11/2023]
Abstract
PURPOSE Diverse radionuclide imaging techniques are available for the diagnosis, staging, and follow-up of phaeochromocytoma and paraganglioma (PPGL). Beyond their ability to detect and localise the disease, these imaging approaches variably characterise these tumours at the cellular and molecular levels and can guide therapy. Here we present updated guidelines jointly approved by the EANM and SNMMI for assisting nuclear medicine practitioners in not only the selection and performance of currently available single-photon emission computed tomography and positron emission tomography procedures, but also the interpretation and reporting of the results. METHODS Guidelines from related fields and relevant literature have been considered in consultation with leading experts involved in the management of PPGL. The provided information should be applied according to local laws and regulations as well as the availability of various radiopharmaceuticals. CONCLUSION Since the European Association of Nuclear Medicine 2012 guidelines, the excellent results obtained with gallium-68 (68Ga)-labelled somatostatin analogues (SSAs) in recent years have simplified the imaging approach for PPGL patients that can also be used for selecting patients for peptide receptor radionuclide therapy as a potential alternative or complement to the traditional theranostic approach with iodine-123 (123I)/iodine-131 (131I)-labelled meta-iodobenzylguanidine. Genomic characterisation of subgroups with differing risk of lesion development and subsequent metastatic spread is refining the use of molecular imaging in the personalised approach to hereditary PPGL patients for detection, staging, and follow-up surveillance.
Collapse
Affiliation(s)
- David Taïeb
- Department of Nuclear Medicine, La Timone University Hospital, CERIMED, Aix-Marseille University, 264 rue Saint-Pierre, 13005, Marseille Cedex 05, France.
| | - Rodney J Hicks
- Centre for Cancer Imaging, Peter MacCallum Cancer Centre, Melbourne, VIC, Australia
| | - Elif Hindié
- Department of Nuclear Medicine, Hôpital Haut-Lévêque, Bordeaux University Hospitals, Pessac, France
| | - Benjamin A Guillet
- Department of Radiopharmacy, La Timone University Hospital, CERIMED, Aix-Marseille University, Marseille, France
| | - Anca Avram
- Nuclear Medicine/Radiology, University of Michigan, Ann Arbor, MI, USA
| | - Pietro Ghedini
- Nuclear Medicine Unit, Medicina Nucleare Metropolitana, University Hospital S.Orsola-Malpighi, Bologna, Italy
| | - Henri J Timmers
- Department of Endocrinology, Radboud University Nijmegen Medical Centre, Nijmegen, The Netherlands
| | | | - Saeed Elojeimy
- Department of Radiology, University of New Mexico, Albuquerque, NM, USA
| | - Domenico Rubello
- Department of Nuclear Medicine, Radiology, Neuroradiology, Medical Physics, Clinical Laboratory, Microbiology, Pathology, Transfusional Medicine, Santa Maria della Misericordia Hospital, Rovigo, Italy
| | - Irène J Virgolini
- Department of Nuclear Medicine, Medical University Innsbruck, Anichstrasse 35, 6020, Innsbruck, Austria
| | - Stefano Fanti
- Nuclear Medicine Unit, Medicina Nucleare Metropolitana, University Hospital S.Orsola-Malpighi, Bologna, Italy
| | - Sona Balogova
- Department of Nuclear Medicine, Comenius University and St. Elisabeth Oncology Institute, Heydukova 10, 81250, Bratislava, Slovakia
- Department of Nuclear Medicine, Hôpital Tenon Assistance Publique-Hôpitaux de Paris and Sorbonne University, Paris, France
| | - Neeta Pandit-Taskar
- Department of Radiology, Molecular Imaging and Therapy Service, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Karel Pacak
- Eunice Kennedy Shriver National Institutes of Child Health and Human Development, National Institutes of Health, Bethesda, MD, USA
| |
Collapse
|
77
|
Bailey DL, Roach PJ. A Brief History of Lung Ventilation and Perfusion Imaging Over the 50-Year Tenure of the Editors of Seminars in Nuclear Medicine. Semin Nucl Med 2019; 50:75-86. [PMID: 31843063 DOI: 10.1053/j.semnuclmed.2019.07.004] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
The ventilation/perfusion lung scan has been in continuous use for approximately half a century, the same lifetime as Seminars in Nuclear Medicine. Remarkably, the founding Editors-in-Chief have continued to guide the journal over this entire period. In this Feschrift issue celebrating their enormous contribution, we review the history of the lung scan, its highs and lows, the transition from planar to SPECT/CT V/Q scans, and the future that is in store in this age of multimodality functional imaging. We concur with the published view of one of the retiring editors (LMF) that V/Q scintigraphy is indeed alive and well and has a definite future in clinical medicine.
Collapse
Affiliation(s)
- Dale L Bailey
- Royal North Shore Hospital, Department of Nuclear Medicine, Sydney, Australia; University of Sydney, Faculty of Medicine & Health, Sydney, Australia.
| | - Paul J Roach
- Royal North Shore Hospital, Department of Nuclear Medicine, Sydney, Australia; University of Sydney, Faculty of Medicine & Health, Sydney, Australia
| |
Collapse
|
78
|
Ogura I, Kobayashi E, Nakahara K, Igarashi K, Haga-Tsujimura M, Toshima H. Quantitative SPECT/CT imaging for medication-related osteonecrosis of the jaw: a preliminary study using volume-based parameters, comparison with chronic osteomyelitis. Ann Nucl Med 2019; 33:776-782. [DOI: 10.1007/s12149-019-01390-5] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2019] [Accepted: 07/17/2019] [Indexed: 12/14/2022]
|
79
|
Abstract
The identification of markers expressed by pathological cells or their microenvironment would help to distinguish such cells from the normal tissues. The strategies derived from this theory can be a promising modality for imaging and treating diseases. LyP-1, a tumor homing peptide, can selectively bind to its receptor p32 protein overexpressed in various tumor-associated cells and atherosclerotic plaque macrophages. During recent decades, multiple types of LyP-1-based imaging probes and drug delivery systems have been designed and developed for diagnostic and therapeutic applications. This review first introduces LyP-1 and its receptor p32, as well as its homing, internalization and proapoptotic properties. Next, we highlight recent studies focusing on the applications of LyP-1-based strategies in the diagnosis and treatment of tumors, metastatic lesions, and atherosclerotic plaques. Finally, several limitations in the clinical translation of LyP-1-based bioconjugates are summarized.
Collapse
Affiliation(s)
- Ningning Song
- a Department of Nuclear Medicine , Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine , Shanghai , People's Republic of China
| | - Lingzhou Zhao
- a Department of Nuclear Medicine , Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine , Shanghai , People's Republic of China
| | - Meilin Zhu
- b School of Basic Medical Sciences, Ningxia Medical University , Yinchuan , People's Republic of China
| | - Jinhua Zhao
- a Department of Nuclear Medicine , Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine , Shanghai , People's Republic of China
| |
Collapse
|
80
|
Ryu H, Meikle SR, Willowson KP, Eslick EM, Bailey DL. Performance evaluation of quantitative SPECT/CT using NEMA NU 2 PET methodology. ACTA ACUST UNITED AC 2019; 64:145017. [DOI: 10.1088/1361-6560/ab2a22] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
81
|
Ryoo HG, Lee WW, Kim JY, Kong E, Choi WH, Yoon JK. Minimum Standardized Uptake Value from Quantitative Bone Single-Photon Emission Computed Tomography/Computed Tomography for Evaluation of Femoral Head Viability in Patients with Femoral Neck Fracture. Nucl Med Mol Imaging 2019; 53:287-295. [PMID: 31456862 DOI: 10.1007/s13139-019-00600-2] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2019] [Revised: 05/16/2019] [Accepted: 06/07/2019] [Indexed: 10/26/2022] Open
Abstract
Purpose Bone single-photon emission computed tomography/computed tomography (SPECT/CT) has been widely used for evaluation of femoral head viability in patients with femoral neck fracture. The current study aimed to investigate utility of standardized uptake value (SUV) from quantitative bone SPECT/CT for assessment of femoral head viability. Methods From March 2015 to November 2018, quantitative bone SPECT/CT was performed in 9 patients with non-viable femoral head post femoral neck fracture and in 31 controls. Maximum (SUVmax), mean (SUVmean), and minimum standardized uptake values (SUVmin) were measured over femoral head and neck. Mann-Whitney U test with Bonferroni correction was used to compare SUVs of ipsilateral and contralateral femurs from femoral neck fracture patients with those of control femurs. Results As for femoral head viability, SUVmax and SUVmean were not significantly decreased in non-viable femoral heads compared to those in controls. Only the SUVmin was significantly reduced in non-viable femoral heads (mean ± standard deviation, 0.57 ± 0.38) than in controls (0.95 ± 0.26, p = 0.006) and contralateral femoral heads (1.36 ± 0.59, p = 0.008). The cutoff SUVmin of 0.61 (g/mL) yielded a sensitivity of 77.8% and specificity of 87.1% for detection of non-viable femoral heads (p = 0.006). Contralateral femoral necks of the femoral neck fracture patients showed significantly higher SUVmean and SUVmin (3.17 ± 1.20 and 1.64 ± 0.63) than those of controls (2.32 ± 0.53 and 1.04 ± 0.27; p = 0.021 and p = 0.002, respectively), which seemed to reflect weight bearing effect or metabolic derangement. Conclusions The non-viable femoral heads from the femoral neck fracture showed significantly reduced SUVmin. Quantitative bone SPECT/CT holds promise for objective evaluation of femoral head viability.
Collapse
Affiliation(s)
- Hyun Gee Ryoo
- 1Department of Nuclear Medicine, Seoul National University Bundang Hospital, Seoul National University College of Medicine, 82, Gumi-ro 173 Beon-gil, Bundang-gu, Seongnam-si, Gyeonggi-do 13620 South Korea
| | - Won Woo Lee
- 1Department of Nuclear Medicine, Seoul National University Bundang Hospital, Seoul National University College of Medicine, 82, Gumi-ro 173 Beon-gil, Bundang-gu, Seongnam-si, Gyeonggi-do 13620 South Korea.,2Institute of Radiation Medicine, Medical Research Center, Seoul National University, Seoul, South Korea
| | - Ji Young Kim
- 3Department of Nuclear Medicine, Hanyang University Guri Hospital, Hanyang University College of Medicine, Seoul, South Korea
| | - Eunjung Kong
- 4Department of Nuclear Medicine, Yeungnam University Medical School and Hospital, Daegu, Gyeongsangbuk-do South Korea
| | - Woo Hee Choi
- 5Division of Nuclear Medicine, Department of Radiology, St. Vincent's Hospital, College of Medicine, The Catholic University of Korea, Seoul, South Korea
| | - Joon-Kee Yoon
- 6Department of Nuclear Medicine & Molecular Imaging, Ajou University School of Medicine, Woldeukeom-ro, Suwon-si, South Korea
| | | |
Collapse
|
82
|
Van den Wyngaert T, Paycha F. Radionuclide imaging and therapy of bone metastases in the era of targeted therapy. THE QUARTERLY JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING : OFFICIAL PUBLICATION OF THE ITALIAN ASSOCIATION OF NUCLEAR MEDICINE (AIMN) [AND] THE INTERNATIONAL ASSOCIATION OF RADIOPHARMACOLOGY (IAR), [AND] SECTION OF THE SOCIETY OF... 2019; 63:95-97. [PMID: 31315348 DOI: 10.23736/s1824-4785.19.03207-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Affiliation(s)
- Tim Van den Wyngaert
- Department of Nuclear Medicine, University Hospital of Antwerp, Edegem, Belgium -
- Faculty of Medicine and Health Sciences, University of Antwerp, Wilrijk, Belgium -
| | - Frédéric Paycha
- Department of Nuclear Medicine, Lariboisière University Hospital, Public Assistance-Paris Hospital, Paris, France
- Paris-Diderot University, Paris, France
| |
Collapse
|
83
|
Dietze MMA, Kunnen B, van der Velden S, Steenbergen JHL, Koppert WJC, Viergever MA, de Jong HWAM. Performance of a dual-layer scanner for hybrid SPECT/CBCT. Phys Med Biol 2019; 64:105020. [PMID: 30947146 DOI: 10.1088/1361-6560/ab15f6] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Fluoroscopic procedures involving radionuclides would benefit from interventional nuclear imaging by obtaining real-time feedback on the activity distribution. We have previously proposed a dual-layer detector that offers such procedural guidance by simultaneous fluoroscopic and nuclear planar imaging. Acquisition of single photon computed tomography (SPECT) and cone beam computed tomography (CBCT) could provide additional information on the activity distribution. This study investigates the feasibility and the image quality of simultaneous SPECT/CBCT, by means of phantom experiments and simulations. Simulations were performed to study the obtained reconstruction quality for (i) clinical SPECT/CT, (ii) a dual-layer scanner configured with optimized hardware, and (iii) our (non-optimized) dual-layer prototype. Experiments on an image quality phantom and an anthropomorphic phantom (including extrahepatic depositions with volumes and activities close to the median values encountered in hepatic radioembolization) were performed with a clinical SPECT/CT scanner and with our dual-layer prototype. Nuclear images were visually and quantitatively evaluated by measuring the tumor/non-tumor (T/N) ratio and contrast-to-noise ratio (CNR). The simulations showed that the maximum obtained CNR was 38.8 ± 0.8 for the clinical scanner, 30.2 ± 0.9 for the optimized dual-layer scanner, and 20.8 ± 0.4 for the prototype scanner. T/N ratio showed a similar decline. The phantom experiments showed that performing simultaneous SPECT/CBCT is feasible. The CNR obtained from the SPECT reconstruction of largest sphere in the image quality phantom was 43.1 for the clinical scanner and 28.6 for the developed prototype scanner. The anthropomorphic phantom showed that the extrahepatic depositions were detected with both scanners. A dual-layer detector is able to simultaneously acquire SPECT and CBCT. Both CNR and T/N ratio are worse than that of a clinical system, but the phantom experiments showed that extrahepatic depositions with volumes and activities close to the median values encountered in hepatic radioembolization could be distinguished.
Collapse
Affiliation(s)
- Martijn M A Dietze
- Radiology and Nuclear Medicine, Utrecht University and University Medical Center Utrecht, PO Box 85500, 3508 GA, Utrecht, The Netherlands. Image Sciences Institute, Utrecht University and University Medical Center Utrecht, PO Box 85500, 3508 GA, Utrecht, The Netherlands. Author to whom any correspondence should be addressed
| | | | | | | | | | | | | |
Collapse
|
84
|
Tzortzakakis A, Holstensson M, Hagel E, Karlsson M, Axelsson R. Intra- and Interobserver Agreement of SUV SPECT Quantitative SPECT/CT Processing Software, Applied in Clinical Settings for Patients with Solid Renal Tumors. J Nucl Med Technol 2019; 47:258-262. [PMID: 31019039 DOI: 10.2967/jnmt.118.223297] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2018] [Accepted: 01/31/2019] [Indexed: 01/10/2023] Open
Abstract
Quantification tools for SPECT/CT are a field of ongoing research among hybrid imaging techniques. A recent multicenter study evaluating SUV SPECT software on phantoms showed that quantitative SPECT/CT is reproducible in Hybrid Viewer software. The aim of our study was to evaluate the intra- and interobserver agreement of quantitative SUV SPECT measurements in clinical settings for patients with solid renal tumors. Methods: The evaluation was part of a study that examined the role of 99mTc-sestamibi SPECT/CT in the characterization of solid kidney tumors and the differentiation of renal oncocytomas from renal cell carcinomas. Quantitative evaluation of SUV measurements was performed in Hybrid Viewer PDR, version 2.5. Forty-eight renal lesions were identified and examined twice by 2 independent readers. The agreement of the SUV measurements, concerning renal tumors and adjacent renal parenchyma, was evaluated using the intraclass correlation coefficient (ICC). Results: ICC for SUVmax measurements by the same reader was 97%-99% for solid renal tumors and 92%-98% for ipsilateral healthy renal parenchyma. ICC for SUVmax measurements between readers was 87%-89% for solid renal tumors and 72%-73% for ipsilateral healthy renal parenchyma. Estimated ICC for SUVmean measurements of solid renal tumors was 95%-98% for the same reader and 86%-89% between readers. Similar results were found for SUVpeak measurements. Conclusion: The high ICCs indicate a strong agreement among SUV measurements for patients with solid renal lesions undergoing 99mTc-sestamibi SPECT/CT, not only for measurements by the same reader but also for measurements between 2 different readers.
Collapse
Affiliation(s)
- Antonios Tzortzakakis
- Division of Radiology, Department for Clinical Science, Intervention, and Technology, Karolinska Institutet and Medical Physics and Nuclear Medicine, Karolinska University Hospital, Huddinge, Sweden .,Division of Medical Imaging and Technology, Department of Neuroradiology, Karolinska University Hospital, Huddinge, Sweden
| | - Maria Holstensson
- Medical Radiation Physics and Nuclear Medicine, Functional Unit of Nuclear Medicine, Karolinska University Hospital, Huddinge, Sweden; and
| | - Eva Hagel
- Learning, Informatics, Management, and Ethics, Medical Statistics Unit, Karolinska Institutet, Stockholm, Sweden
| | - Mattias Karlsson
- Medical Radiation Physics and Nuclear Medicine, Functional Unit of Nuclear Medicine, Karolinska University Hospital, Huddinge, Sweden; and
| | - Rimma Axelsson
- Division of Radiology, Department for Clinical Science, Intervention, and Technology, Karolinska Institutet and Medical Physics and Nuclear Medicine, Karolinska University Hospital, Huddinge, Sweden.,Medical Radiation Physics and Nuclear Medicine, Functional Unit of Nuclear Medicine, Karolinska University Hospital, Huddinge, Sweden; and
| |
Collapse
|
85
|
Arvola S, Jambor I, Kuisma A, Kemppainen J, Kajander S, Seppänen M, Noponen T. Comparison of standardized uptake values between 99mTc-HDP SPECT/CT and 18F-NaF PET/CT in bone metastases of breast and prostate cancer. EJNMMI Res 2019; 9:6. [PMID: 30680469 PMCID: PMC6346696 DOI: 10.1186/s13550-019-0475-z] [Citation(s) in RCA: 44] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2018] [Accepted: 01/15/2019] [Indexed: 11/25/2022] Open
Abstract
Background Despite recent technological advances allowing for quantitative single-photon emission computed tomography (SPECT), quantitative SPECT has not been widely used in the clinical practice. The aim of this study is to evaluate the feasibility of quantitative SPECT for measuring metastatic bone uptake in breast and prostate cancer by comparing standard uptake values (SUVs) measured with 99mTc-HDP SPECT/CT and 18F-NaF PET/CT. Methods Twenty-six breast and 27 prostate cancer patients at high risk of bone metastases underwent both 99mTc-HDP SPECT/CT and 18F-NaF PET/CT within 14 days of each other. The SPECT and PET data were reconstructed using ordered-subset expectation-maximization algorithms achieving quantitative images. Metastatic and benign skeletal lesions visible in both data sets were identified, and their maximum, peak, and mean SUVs (SUVmax, SUVpeak, and SUVmean) were determined. SUV ratios (SUVRs) between the lesions and adjacent normal appearing bone were also calculated. Linear regression was used to evaluate the correlations between the SUVs of SPECT and PET and Bland-Altman plots to evaluate the differences between the SUVs and SUVRs of SPECT and PET. Results A total of 231 skeletal lesions, 129 metastatic and 102 benign, were analyzed. All three SUV measures correlated very strongly between SPECT and PET (R2 ≥ 0.80, p < 0.001) when all lesions were included, and the PET SUVs were significantly higher than SPECT SUVs (p < 0.001). The median differences were 21%, 12%, and 19% for SUVmax, SUVpeak, and SUVmean, respectively. On the other hand, the SUVRs were similar between SPECT and PET with median differences of 2%, − 9%, and 2% for SUVRmax, SUVRpeak, and SUVRmean, respectively. Conclusion The strong correlation between SUVs and similar SUVRs of 99mTc-HDP SPECT/CT and 18F-NaF PET/CT demonstrate that SPECT is an applicable tool for clinical quantification of bone metabolism in osseous metastases in breast and prostate cancer patients.
Collapse
Affiliation(s)
- Samuli Arvola
- Department of Clinical Physiology and Nuclear Medicine, Turku University Hospital, Kiinamyllynkatu 4-8, 20521, Turku, Finland.
| | - Ivan Jambor
- Department of Diagnostic Radiology, University of Turku, Turku, Finland
| | - Anna Kuisma
- Department of Oncology and Radiotherapy, University of Turku, Turku, Finland
| | | | | | - Marko Seppänen
- Department of Clinical Physiology and Nuclear Medicine, Turku University Hospital, Kiinamyllynkatu 4-8, 20521, Turku, Finland.,Turku PET Centre, Turku, Finland
| | - Tommi Noponen
- Department of Clinical Physiology and Nuclear Medicine, Turku University Hospital, Kiinamyllynkatu 4-8, 20521, Turku, Finland.,Department of Medical Physics, Turku University Hospital, Turku, Finland
| |
Collapse
|
86
|
Kita A, Sugimoto K, Kosaka N, Onoguchi M, Shibutani T, Adachi T. [Simplification of Activity Measurement during Quantitative Value Estimation in Bone SPECT]. Nihon Hoshasen Gijutsu Gakkai Zasshi 2019; 75:1158-1164. [PMID: 31631109 DOI: 10.6009/jjrt.2019_jsrt_75.10.1158] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
PURPOSE To calculate the quantitative values in bone single-photon emission computed tomography, it is necessary to measure the amount of syringe radiation before and after the administration of a radiopharmaceutical. We proposed a method to omit the measurement of radioactivity. In this study, we clarified the effects of adopting this method and calculated its influence on quantitative values in a clinical setting. METHODS We derived a relational expression of the administration time and dose of radioactivity from the measured value and the administration time of the syringe dose before and after the administration in each patient. Next, we determined the differences for radioactivity calculated from this relational expression (estimated dose) and actual administered radioactivity (actual dose). Furthermore, we calculated the differences in the quantitative values of a normal region (the fourth lumbar vertebra) on adopting these data. RESULTS No significant differences between the estimated dose and actual dose were noted. Additionally, no significant differences in the quantitative values were observed. CONCLUSION Our findings suggest that adoption of the estimated dose does not affect the quantitative value. When the estimated dose is adopted, it can be administered with an accuracy of 0.80%. Thus, it is possible to omit the actual measurement of radioactivity by using our proposed method.
Collapse
Affiliation(s)
- Akinobu Kita
- Radiological Center, University of Fukui Hospital
- Department of Quantum Medical Technology, Graduate School of Medical Sciences, Kanazawa University
| | | | - Nobuyuki Kosaka
- Department of Radiology, Faculty of Medical Sciences, University of Fukui
| | - Masahisa Onoguchi
- Department of Quantum Medical Technology, Graduate School of Medical Sciences, Kanazawa University
- Department of Quantum Medical Technology, Institute of Medical, Pharmaceutical and Health Sciences, Kanazawa University
| | - Takayuki Shibutani
- Department of Quantum Medical Technology, Graduate School of Medical Sciences, Kanazawa University
- Department of Quantum Medical Technology, Institute of Medical, Pharmaceutical and Health Sciences, Kanazawa University
| | - Toshiki Adachi
- Radiological Center, University of Fukui Hospital (Current address: Niigata University of Health and Welfare)
| |
Collapse
|
87
|
Mohy-Ud-Din H, Boutagy NE, Stendahl JC, Zhuang ZW, Sinusas AJ, Liu C. Quantification of intramyocardial blood volume with 99mTc-RBC SPECT-CT imaging: A preclinical study. J Nucl Cardiol 2018; 25:2096-2111. [PMID: 28695406 PMCID: PMC5985225 DOI: 10.1007/s12350-017-0970-4] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2016] [Revised: 06/13/2017] [Indexed: 10/19/2022]
Abstract
BACKGROUND Currently, there is no established non-invasive imaging approach to directly evaluate myocardial microcirculatory function in order to diagnose microvascular disease independent of co-existing epicardial disease. In this work, we developed a methodological framework for quantification of intramyocardial blood volume (IMBV) as a novel index of microcirculatory function with SPECT/CT imaging of 99mTc-labeled red blood cells (RBCs). METHODS Dual-gated myocardial SPECT/CT equilibrium imaging of 99mTc-RBCs was performed on twelve canines under resting conditions. Five correction schemes were studied: cardiac gating with no other corrections (CG), CG with attenuation correction (CG + AC), CG + AC with scatter correction (CG + AC + SC), dual cardiorespiratory gating with AC + SC (DG + AC + SC), and DG + AC + SC with partial volume correction (DG + AC + SC + PVC). Quantification of IMBV using each approach was evaluated in comparison to those obtained from all corrections. The in vivo SPECT estimates of IMBV values were validated against those obtained from ex vivo microCT imaging of the casted hearts. RESULTS The estimated IMBV with all corrections was 0.15 ± 0.03 for the end-diastolic phase and 0.11 ± 0.03 for the end-systolic phase. The cycle-dependent change in IMBV (ΔIMBV) with all corrections was 23.9 ± 8.6%. Schemes that applied no correction or partial correction resulted in significant over-estimation of IMBV and significant under-underestimation of ΔIMBV. Estimates of IMBV and ΔIMBV using all corrections were consistent with values reported in the literature using invasive techniques. In vivo SPECT estimates of IMBV strongly correlated (R2 ≥ 0.70) with ex vivo measures for the various correction schemes, while the fully corrected scheme yielded the smallest bias. CONCLUSIONS Non-invasive quantification of IMBV is feasible using 99mTc-RBCs SPECT/CT imaging, however, requires full compensation of physical degradation factors.
Collapse
Affiliation(s)
- Hassan Mohy-Ud-Din
- Department of Radiology and Biomedical Imaging, Yale University, New Haven, CT, USA.
- Shaukat Khanum Memorial Cancer Hospital and Research Center, 7-A, Block R-3, Johar Town, Lahore, 54000, Pakistan.
| | - Nabil E Boutagy
- Section of Cardiovascular Medicine, Department of Medicine, Yale University School of Medicine, New Haven, CT, USA
| | - John C Stendahl
- Section of Cardiovascular Medicine, Department of Medicine, Yale University School of Medicine, New Haven, CT, USA
| | - Zhen W Zhuang
- Section of Cardiovascular Medicine, Department of Medicine, Yale University School of Medicine, New Haven, CT, USA
| | - Albert J Sinusas
- Department of Radiology and Biomedical Imaging, Yale University, New Haven, CT, USA
- Section of Cardiovascular Medicine, Department of Medicine, Yale University School of Medicine, New Haven, CT, USA
| | - Chi Liu
- Department of Radiology and Biomedical Imaging, Yale University, New Haven, CT, USA.
| |
Collapse
|
88
|
Bastiaannet R, Kappadath SC, Kunnen B, Braat AJAT, Lam MGEH, de Jong HWAM. The physics of radioembolization. EJNMMI Phys 2018; 5:22. [PMID: 30386924 PMCID: PMC6212377 DOI: 10.1186/s40658-018-0221-z] [Citation(s) in RCA: 72] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2017] [Accepted: 06/19/2018] [Indexed: 12/11/2022] Open
Abstract
Radioembolization is an established treatment for chemoresistant and unresectable liver cancers. Currently, treatment planning is often based on semi-empirical methods, which yield acceptable toxicity profiles and have enabled the large-scale application in a palliative setting. However, recently, five large randomized controlled trials using resin microspheres failed to demonstrate a significant improvement in either progression-free survival or overall survival in both hepatocellular carcinoma and metastatic colorectal cancer. One reason for this might be that the activity prescription methods used in these studies are suboptimal for many patients.In this review, the current dosimetric methods and their caveats are evaluated. Furthermore, the current state-of-the-art of image-guided dosimetry and advanced radiobiological modeling is reviewed from a physics' perspective. The current literature is explored for the observation of robust dose-response relationships followed by an overview of recent advancements in quantitative image reconstruction in relation to image-guided dosimetry.This review is concluded with a discussion on areas where further research is necessary in order to arrive at a personalized treatment method that provides optimal tumor control and is clinically feasible.
Collapse
Affiliation(s)
- Remco Bastiaannet
- Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, Room E01.132, P.O. Box 85500, 3508 GA Utrecht, The Netherlands
| | - S. Cheenu Kappadath
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, 1155 Pressler St, Unit 1352, Houston, TX 77030 USA
| | - Britt Kunnen
- Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, Room E01.132, P.O. Box 85500, 3508 GA Utrecht, The Netherlands
| | - Arthur J. A. T. Braat
- Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, Room E01.132, P.O. Box 85500, 3508 GA Utrecht, The Netherlands
| | - Marnix G. E. H. Lam
- Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, Room E01.132, P.O. Box 85500, 3508 GA Utrecht, The Netherlands
| | - Hugo W. A. M. de Jong
- Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, Room E01.132, P.O. Box 85500, 3508 GA Utrecht, The Netherlands
| |
Collapse
|
89
|
Gonzalez AJ, Sanchez F, Benlloch JM. Organ-Dedicated Molecular Imaging Systems. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES 2018. [DOI: 10.1109/trpms.2018.2846745] [Citation(s) in RCA: 47] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
90
|
Ramsay SC, Lindsay K, Fong W, Patford S, Younger J, Atherton J. Tc-HDP quantitative SPECT/CT in transthyretin cardiac amyloid and the development of a reference interval for myocardial uptake in the non-affected population. Eur J Hybrid Imaging 2018; 2:17. [PMID: 30175320 PMCID: PMC6105142 DOI: 10.1186/s41824-018-0035-1] [Citation(s) in RCA: 40] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2018] [Accepted: 05/31/2018] [Indexed: 12/22/2022] Open
Abstract
Background 99mTechnetium-HDP (HDP) bone scans differentiate transthyretin (ATTR) cardiac amyloid from other infiltrative myocardial diseases. These scans are not quantitative and are assessed by comparing myocardial uptake to bone. This study examined whether quantitative HDP SPECT/CT can discriminate individuals with cardiac ATTR from the population without this disease. Methods HDP thoracic xSPECT/CT QUANT (xQUANT) was performed in 29 patients: ATTR cardiac amyloid (n = 6); AL cardiac amyloid (n = 1); other infiltrative myocardial disease (n = 4); no known infiltrative cardiac disease (n = 18). SUVmax measured within volumes of interest for whole heart, ascending aorta blood pool, and specific bones. HDP myocardial uptake calculated as whole heart minus blood pool. Results The cardiac ATTR group had greater HDP myocardial uptake than those with no known infiltrative disease (p = 0.002). AL and other myocardial diseases had uptake indistinguishable from the group with no known infiltrative cardiac disease. The SUVmaxima were sufficiently similar between individuals without cardiac ATTR that a 99% reference interval for HDP uptake could be calculated, providing an upper limit cut point of SUVmax 1.2. Individuals with cardiac ATTR had SUVmax well above this cut point. Conclusion Quantitative SPECT/CT can measure HDP myocardial uptake in individuals with normal hearts and those with cardiac ATTR without recourse to comparison with bone. It enables calculation of a reference interval for HDP myocardial uptake in the population without ATTR cardiac amyloid. Using this reference interval single individuals with cardiac ATTR can be accurately discriminated from the non-affected population. This technique uses a NIST traceable calibration source, potentially allowing development of multicentre clinical decision limits. Its role in disease management warrants further assessment.
Collapse
Affiliation(s)
- Stuart C Ramsay
- 1Department of Nuclear Medicine and Specialised PET Service, Ned Hanlon Building, Royal Brisbane and Women's Hospital (RBWH), Herston, QLD 4029 Australia.,2School of Medicine, James Cook University, Douglas, QLD 4811 Australia
| | - Karen Lindsay
- 1Department of Nuclear Medicine and Specialised PET Service, Ned Hanlon Building, Royal Brisbane and Women's Hospital (RBWH), Herston, QLD 4029 Australia
| | - William Fong
- 1Department of Nuclear Medicine and Specialised PET Service, Ned Hanlon Building, Royal Brisbane and Women's Hospital (RBWH), Herston, QLD 4029 Australia
| | - Shaun Patford
- 1Department of Nuclear Medicine and Specialised PET Service, Ned Hanlon Building, Royal Brisbane and Women's Hospital (RBWH), Herston, QLD 4029 Australia
| | - John Younger
- 3Department of Cardiology RBWH, Herston, QLD 4029 Australia
| | - John Atherton
- 3Department of Cardiology RBWH, Herston, QLD 4029 Australia.,4School of Clinical Medicine, Faculty of Medicine, University of Queensland, Heston, QLD 4006 Australia
| |
Collapse
|
91
|
Verger A, Klesse E, Chawki MB, Witjas T, Azulay J, Eusebio A, Guedj E. Brain PET substrate of impulse control disorders in Parkinson's disease: A metabolic connectivity study. Hum Brain Mapp 2018; 39:3178-3186. [PMID: 29635851 PMCID: PMC6866256 DOI: 10.1002/hbm.24068] [Citation(s) in RCA: 30] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2018] [Revised: 03/21/2018] [Accepted: 03/23/2018] [Indexed: 12/21/2022] Open
Abstract
Impulse control disorders (ICDs) have received increased attention in Parkinson's disease (PD) because of potentially dramatic consequences. Their physiopathology, however, remains incompletely understood. An overstimulation of the mesocorticolimbic system has been reported, while a larger network has recently been suggested. The aim of this study is to specifically describe the metabolic PET substrate and related connectivity changes in PD patients with ICDs. Eighteen PD patients with ICDs and 18 PD patients without ICDs were evaluated using cerebral 18F-fluorodeoxyglucose positron emission tomography. SPM-T maps comparisons were performed between groups and metabolic connectivity was evaluated by interregional correlation analysis (IRCA; p < .005, uncorrected; k > 130) and by graph theory (p < .05). PD patients with ICDs had relative increased metabolism in the right middle and inferior temporal gyri compared to those without ICDs. The connectivity of this area was increased mostly with the mesocorticolimbic system, positively with the orbitofrontal region, and negatively with both the right parahippocampus and the left caudate (IRCA). Moreover, the betweenness centrality of this area with the mesocorticolimbic system was lost in patients with ICDs (graph analysis). ICDs are associated in PD with the dysfunction of a network exceeding the mesocorticolimbic system, and especially the caudate, the parahippocampus, and the orbitofrontal cortex, remotely including the right middle and inferior temporal gyri. This latest area loses its central place with the mesocorticolimbic system through a connectivity dysregulation.
Collapse
Affiliation(s)
- Antoine Verger
- Department of Nuclear MedicineAssistance Publique‐Hôpitaux de Marseille, Aix‐Marseille Université, Timone University HospitalProvence‐Alpes‐Côte d'AzurFrance
- Department of Nuclear Medicine & Nancyclotep Imaging platformCHRU NancyNancyF‐54000France
- Université de Lorraine, INSERM, IADINancyF‐54000France
| | - Elsa Klesse
- Department of Neurology and Movement DisordersAssistance Publique‐Hôpitaux de Marseille, Aix‐Marseille Université, Timone University HospitalProvence‐Alpes‐Côte d'AzurFrance
- Aix Marseille Univ, CNRS, Centrale Marseille, Institut FresnelMarseilleFrance
| | - Mohammad B. Chawki
- Department of Nuclear Medicine & Nancyclotep Imaging platformCHRU NancyNancyF‐54000France
| | - Tatiana Witjas
- Department of Neurology and Movement DisordersAssistance Publique‐Hôpitaux de Marseille, Aix‐Marseille Université, Timone University HospitalProvence‐Alpes‐Côte d'AzurFrance
- Aix Marseille Univ, CNRS, Centrale Marseille, Institut FresnelMarseilleFrance
| | - Jean‐Philippe Azulay
- Department of Neurology and Movement DisordersAssistance Publique‐Hôpitaux de Marseille, Aix‐Marseille Université, Timone University HospitalProvence‐Alpes‐Côte d'AzurFrance
- Aix Marseille Univ, CNRS, Centrale Marseille, Institut FresnelMarseilleFrance
| | - Alexandre Eusebio
- Department of Neurology and Movement DisordersAssistance Publique‐Hôpitaux de Marseille, Aix‐Marseille Université, Timone University HospitalProvence‐Alpes‐Côte d'AzurFrance
- Aix Marseille Univ, CNRS, Centrale Marseille, Institut FresnelMarseilleFrance
| | - Eric Guedj
- Department of Nuclear MedicineAssistance Publique‐Hôpitaux de Marseille, Aix‐Marseille Université, Timone University HospitalProvence‐Alpes‐Côte d'AzurFrance
- Aix Marseille Univ, CNRS, Centrale Marseille, Institut FresnelMarseilleFrance
- CERIMED, Aix‐Marseille UniversitéMarseilleFrance
| |
Collapse
|
92
|
Yamane T, Kuji I, Seto A, Matsunari I. Quantification of osteoblastic activity in epiphyseal growth plates by quantitative bone SPECT/CT. Skeletal Radiol 2018; 47:805-810. [PMID: 29327129 DOI: 10.1007/s00256-017-2861-9] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/13/2017] [Revised: 12/03/2017] [Accepted: 12/19/2017] [Indexed: 02/02/2023]
Abstract
OBJECTIVE Quantifying the function of the epiphyseal plate is worthwhile for the management of children with growth disorders. The aim of this retrospective study was to quantify the osteoblastic activity at the epiphyseal plate using the quantitative bone SPECT/CT. MATERIALS AND METHODS We enrolled patients under the age of 20 years who received Tc-99m hydroxymethylene diphosphonate bone scintigraphy acquired by a quantitative SPECT/CT scanner. The images were reconstructed by ordered subset conjugate-gradient minimizer, and the uptake on the distal margin of the femur was quantified by peak standardized uptake value (SUVpeak). A public database of standard body height was used to calculate growth velocities (cm/year). RESULTS Fifteen patients (6.9-19.7 years, 9 female, 6 male) were enrolled and a total of 25 legs were analyzed. SUVpeak in the epiphyseal plate was 18.9 ± 2.4 (average ± standard deviation) in the subjects under 15 years and decreased gradually by aging. The SUVpeak correlated significantly with the age- and sex-matched growth velocity obtained from the database (R2 = 0.83, p < 0.0001). CONCLUSION The SUV measured by quantitative bone SPECT/CT was increased at the epiphyseal plates of children under the age of 15 years in comparison with the older group, corresponding to higher osteoblastic activity. Moreover, this study suggested a correlation between growth velocity and the SUV. Although this is a small retrospective pilot study, the objective and quantitative values measured by the quantitative bone SPECT/CT has the potential to improve the management of children with growth disorder.
Collapse
Affiliation(s)
- Tomohiko Yamane
- Department of Nuclear Medicine, Saitama Medical University International Medical Center, 1397-1 Yamane, Hidaka, 350-1298, Japan.
| | - Ichiei Kuji
- Department of Nuclear Medicine, Saitama Medical University International Medical Center, 1397-1 Yamane, Hidaka, 350-1298, Japan
| | - Akira Seto
- Department of Nuclear Medicine, Saitama Medical University International Medical Center, 1397-1 Yamane, Hidaka, 350-1298, Japan
| | - Ichiro Matsunari
- Division of Nuclear Medicine, Department of Radiology, Saitama Medical University Hospital, Moroyama, Japan
| |
Collapse
|
93
|
Halty A, Badel JN, Kochebina O, Sarrut D. Image-based SPECT calibration based on the evaluation of the Fraction of Activity in the Field of View. EJNMMI Phys 2018; 5:11. [PMID: 29766354 PMCID: PMC5953912 DOI: 10.1186/s40658-018-0209-8] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2017] [Accepted: 03/16/2018] [Indexed: 11/27/2022] Open
Abstract
Background SPECT quantification is important for dosimetry in targeted radionuclide therapy (TRT) and the calibration of SPECT images is a crucial stage for image quantification. The current standardized calibration protocol (MIRD 23) uses phantom acquisitions to derive a global calibration factor in specific conditions. It thus requires specific acquisitions for every clinical protocols. We proposed an alternative and complementary image-based calibration method that allows to determine a calibration factor adapted to each patient, radionuclide, and acquisition protocol and that may also be used as an additional independent calibration. Results The proposed method relies on a SPECT/CT acquisition of a given region of interest and an initial whole-body (WB) planar image. First, the conjugate view of WB planar images is computed after scatter and attenuation correction. 3D SPECT images are reconstructed with scatter, attenuation, and collimator-detector response (CDR) corrections and corrected from apparent dead-time. The field of view (FOV) of the SPECT image is then projected on the corrected WB planar image. The fraction of activity located in the area corresponding to the SPECT FOV is then calculated based on the counts on the corrected WB planar image. The Fraction of Activity in Field Of View (FAF) is then proposed to compute the calibration factor as the total number of counts in the SPECT image divided by this activity. Quantification accuracy was compared with the standard calibration method both with phantom experiments and on patient data. Both standard and image-based calibrations give good accuracy on large region of interest on phantom experiments (less than 7% of relative difference compared to ground truth). Apparent dead-time correction allows to reduce the uncertainty associated with standard calibration from 2.5 to 1%. The differences found between both methods were lower than the uncertainty range of the standard calibration (<3%). In patient data, although no ground truth was available, both methods give similar calibration factor (average difference 3.64%). Conclusions A calibration factor may be computed directly from the acquired SPECT image providing that a WB planar image is also available and if both acquisitions are performed before biological elimination. This method does not require to perform phantom acquisition for every different acquisition conditions and may serve to double check the calibration with an independent factor.
Collapse
Affiliation(s)
- Adrien Halty
- Univ Lyon, INSA-Lyon, Université Lyon 1, CNRS, Inserm, CREATIS UMR 5220, U1206, Lyon, 69008, France. .,Univ Lyon, Centre Léon Bérard, Lyon, 69008, France.
| | | | - Olga Kochebina
- Univ Lyon, INSA-Lyon, Université Lyon 1, CNRS, Inserm, CREATIS UMR 5220, U1206, Lyon, 69008, France
| | - David Sarrut
- Univ Lyon, INSA-Lyon, Université Lyon 1, CNRS, Inserm, CREATIS UMR 5220, U1206, Lyon, 69008, France.,Univ Lyon, Centre Léon Bérard, Lyon, 69008, France
| |
Collapse
|
94
|
Determination of gamma camera calibration factors for quantitation of therapeutic radioisotopes. EJNMMI Phys 2018; 5:8. [PMID: 29717385 PMCID: PMC5930296 DOI: 10.1186/s40658-018-0208-9] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2017] [Accepted: 02/23/2018] [Indexed: 01/23/2023] Open
Abstract
Background Camera calibration, which translates reconstructed count map into absolute activity map, is a prerequisite procedure for quantitative SPECT imaging. Both planar and tomographic scans using different phantom geometries have been proposed for the determination of the camera calibration factor (CF). However, there is no consensus on which approach is the best. The aim of this study is to evaluate all these calibration methods, compare their performance, and propose a practical and accurate calibration method for SPECT quantitation of therapeutic radioisotopes. Twenty-one phantom experiments (Siemens Symbia SPECT/CT) and 12 Monte Carlo simulations (GATE v6.1) using three therapy isotopes (131I, 177Lu, and 188Re) have been performed. The following phantom geometries were used: (1) planar scans of point source in air (PS), (2) tomographic scans of insert(s) filled with activity placed in non-radioactive water (HS + CB), (3) tomographic scans of hot insert(s) in radioactive water (HS + WB), and (4) tomographic scans of cylinders uniformly filled with activity (HC). Tomographic data were reconstructed using OSEM with CT-based attenuation correction and triple energy window (TEW) scatter correction, and CF was determined using total counts in the reconstructed image, while for planar scans, the photopeak counts, corrected for scatter and background with TEW, were used. Additionally, for simulated data, CF obtained from primary photons only was analyzed. Results For phantom experiments, CF obtained from PS and HS + WB agreed to within 6% (below 3% if experiments performed on the same day are considered). However, CF from HS + CB exceeded those from PS by 4–12%. Similar trend was found in simulation studies. Analysis of CFs from primary photons helped us to understand this discrepancy. It was due to underestimation of scatter by the TEW method, further enhanced by attenuation correction. This effect becomes less important when the source is distributed over the entire phantom volume (HS + WB and HC). Conclusions Camera CF could be determined using planar scans of a point source, provided that the scatter and background contributions are removed, for example using the clinically available TEW method. This approach is simple and yet provides CF with sufficient accuracy (~ 5%) to be used in clinics for radiotracer quantification.
Collapse
|
95
|
Collarino A, Pereira Arias-Bouda LM, Valdés Olmos RA, van der Tol P, Dibbets-Schneider P, de Geus-Oei LF, van Velden FHP. Experimental validation of absolute SPECT/CT quantification for response monitoring in breast cancer. Med Phys 2018; 45:2143-2153. [PMID: 29572848 DOI: 10.1002/mp.12880] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2017] [Revised: 03/02/2018] [Accepted: 03/08/2018] [Indexed: 01/01/2023] Open
Abstract
PURPOSE Recent developments in iterative image reconstruction enable absolute quantification of SPECT/CT studies by incorporating compensation for collimator-detector response, attenuation, and scatter as well as resolution recovery into the reconstruction process (Evolution; Q.Metrix package; GE Healthcare, Little Chalfont, UK). The aim of this experimental study is to assess its quantitative accuracy for potential clinical 99m Tc-sestamibi (MIBI)-related SPECT/CT application in neoadjuvant chemotherapy response studies in breast cancer. METHODS Two phantoms were filled with MIBI and acquired on a SPECT/CT gamma camera (Discovery 670 Pro; GE Healthcare), that is, a water cylinder and a NEMA body phantom containing six spheres that were filled with an activity concentration reflecting clinical MIBI uptake. Subsequently, volumes-of-interest (VOI) of each sphere were drawn (semi)automatically on SPECT using various isocontour methods or manually on CT. Finally, prone MIBI SPECT/CT scans were acquired 5 and 90 min p.i. in a locally advanced breast cancer patient. RESULTS Activity concentration in the four largest spheres converged after nine iterations of evolution. Depending on the count statistics, the accuracy of the reconstructed activity concentration varied between -4.7 and -0.16% (VOI covering the entire phantom) and from 6.9% to 10% (8.8 cm ⌀ cylinder VOI placed in the center of the phantom). Recovery coefficients of SUVmax were 1.89 ± 0.18, 1.76 ± 0.17, 2.00 ± 0.38, 1.89 ± 0.35, and 0.90 ± 0.26 for spheres with 37, 28, 22, 17, and 13 mm ⌀, respectively. Recovery coefficients of SUVmean were 1.07 ± 0.06, 1.03 ± 0.09, 1.17 ± 0.21, 1.10 ± 0.20, and 0.52 ± 0.14 (42% isocontour); 1.10 ± 0.07, 1.02 ± 0.09, 1.13 ± 0.19, 1.06 ± 0.19, and 0.51 ± 0.13 (36% isocontour with local background correction); and 0.96, 1.09, 1.03, 1.03, and 0.29 (CT). Patient study results were concordant with the phantom validation. CONCLUSIONS Absolute SPECT/CT quantification of breast studies using MIBI seems feasible (<17% deviation) when a 42% isocontour is used for delineation for tumors of at least 17 mm diameter. However, with tumor shrinkage, response evaluation should be handled with caution, especially when using SUVmax .
Collapse
Affiliation(s)
- Angela Collarino
- Section of Nuclear Medicine, Department of Radiology, Leiden University Medical Center, Albinusdreef 2, 2333 ZA, Leiden, The Netherlands.,Biomedical Photonic Imaging Group, MIRA Institute University of Twente, PO Box 217, 7500 AE, Enschede, The Netherlands
| | - Lenka M Pereira Arias-Bouda
- Section of Nuclear Medicine, Department of Radiology, Leiden University Medical Center, Albinusdreef 2, 2333 ZA, Leiden, The Netherlands.,Department of Nuclear Medicine, Alrijne Ziekenhuis, Simon Smitweg 1, 2353 GA, Leiderdorp, The Netherlands
| | - Renato A Valdés Olmos
- Section of Nuclear Medicine, Department of Radiology, Leiden University Medical Center, Albinusdreef 2, 2333 ZA, Leiden, The Netherlands.,Interventional Molecular Imaging Laboratory, Department of Radiology, Leiden University Medical Center, Albinusdreef 2, 2333 ZA, Leiden, The Netherlands.,Department of Nuclear Medicine, The Netherlands Cancer Institute-Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX, Amsterdam, The Netherlands
| | - Pieternel van der Tol
- Medical Physics, Department of Radiology, Leiden University Medical Center, Albinusdreef 2, 2333 ZA, Leiden, The Netherlands
| | - Petra Dibbets-Schneider
- Section of Nuclear Medicine, Department of Radiology, Leiden University Medical Center, Albinusdreef 2, 2333 ZA, Leiden, The Netherlands
| | - Lioe-Fee de Geus-Oei
- Section of Nuclear Medicine, Department of Radiology, Leiden University Medical Center, Albinusdreef 2, 2333 ZA, Leiden, The Netherlands.,Biomedical Photonic Imaging Group, MIRA Institute University of Twente, PO Box 217, 7500 AE, Enschede, The Netherlands
| | - Floris H P van Velden
- Section of Nuclear Medicine, Department of Radiology, Leiden University Medical Center, Albinusdreef 2, 2333 ZA, Leiden, The Netherlands.,Medical Physics, Department of Radiology, Leiden University Medical Center, Albinusdreef 2, 2333 ZA, Leiden, The Netherlands
| |
Collapse
|
96
|
Schmitt V, Rodríguez-Rodríguez C, Hamilton JL, Shenoi RA, Schaffer P, Sossi V, Kizhakkedathu JN, Saatchi K, Häfeli UO. Quantitative SPECT imaging and biodistribution point to molecular weight independent tumor uptake for some long-circulating polymer nanocarriers. RSC Adv 2018; 8:5586-5595. [PMID: 35542449 PMCID: PMC9078196 DOI: 10.1039/c7ra09183d] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2017] [Accepted: 01/20/2018] [Indexed: 11/21/2022] Open
Abstract
Polymeric nanocarriers are promising entities for cancer diagnosis and therapy. The aim of such nanocarriers is to selectively accumulate in cancerous tissue that is difficult to visualize or treat. The passive accumulation of a nanocarrier in a tumor through extravasation is often attributed to the enhanced permeation and retention (EPR) effect and the size and shape of the nanocarrier. However, the tumor microenvironment is very heterogeneous and the intratumoral pressure is usually high, leading to different opinions about how the EPR of nanocarriers through the irregular vasculature of a tumor leads to accumulation. In order to investigate this topic, we studied methods for the determination of pharmacokinetic parameters, biodistribution and the tumor uptake of nanocarriers. More specifically, we used non-invasive quantitative Single-Photon Emission Computed Tomography/Computed Tomography (qSPECT/CT) imaging of hyperbranched polyglycerols (HPGs) to explore the specific biodistribution and tumor uptake of six model nanocarriers in Rag2m mice. We were interested to see if a distinct molecular weight (MW) of nanocarriers (HPG 25, 50, 100, 200, 300, 500 kDa) is favoured by the tumor. To trace the model nanocarriers, HPGs were covalently linked to the strong chelator desferrioxamine (DFO), and radiolabeled with the gamma emitter 67Ga (EC = 100%, E γ = 185 keV (21.4%), 300 keV (16.6%), half-life = 3.26 d). Without the need for blood collection, but instead using qSPECT/CT imaging inside the heart, the blood circulation half-lives of the 67Ga labeled HPGs were determined and increased from 9.9 ± 2.9 to 47.8 ± 7.9 hours with increasing polymer MW. Total tumor accumulation correlated positively with the circulation time of the HPGs. Comparing the tumor-to-blood ratio dynamically revealed how blood and tumor concentrations of the nanocarrier change over time and when equilibrium is reached. The time of equilibrium is size-dependent and increases with molecular weight. Furthermore, the data indicate that for larger MWs, nanocarrier uptake and retention by the tumor is size independent. Further studies are necessary to advance our understanding of the interplay between MW and nanoparticle accumulation in tumors.
Collapse
Affiliation(s)
- V Schmitt
- The University of British Columbia, Faculty of Pharmaceutical Sciences 2405 Wesbrook Mall Vancouver BC V6T1Z3 Canada
| | - C Rodríguez-Rodríguez
- The University of British Columbia, Faculty of Pharmaceutical Sciences 2405 Wesbrook Mall Vancouver BC V6T1Z3 Canada
- Department of Physics & Astronomy, The University of British Columbia Vancouver BC Canada
- Centre for Comparative Medicine, The University of British Columbia Vancouver BC Canada
| | - J L Hamilton
- Centre for Blood Research, Department of Pathology and Laboratory Medicine, The University of British Columbia Vancouver BC Canada
| | - R A Shenoi
- Centre for Blood Research, Department of Pathology and Laboratory Medicine, The University of British Columbia Vancouver BC Canada
| | - P Schaffer
- TRIUMF 4004 Wesbrook Mall Vancouver BC Canada
| | - V Sossi
- Department of Physics & Astronomy, The University of British Columbia Vancouver BC Canada
| | - J N Kizhakkedathu
- Centre for Blood Research, Department of Pathology and Laboratory Medicine, The University of British Columbia Vancouver BC Canada
- Department of Chemistry, The University of British Columbia Vancouver BC Canada
| | - K Saatchi
- The University of British Columbia, Faculty of Pharmaceutical Sciences 2405 Wesbrook Mall Vancouver BC V6T1Z3 Canada
| | - U O Häfeli
- The University of British Columbia, Faculty of Pharmaceutical Sciences 2405 Wesbrook Mall Vancouver BC V6T1Z3 Canada
| |
Collapse
|
97
|
Porter CA, Bradley KM, Hippeläinen ET, Walker MD, McGowan DR. Phantom and clinical evaluation of the effect of full Monte Carlo collimator modelling in post-SIRT yttrium-90 Bremsstrahlung SPECT imaging. EJNMMI Res 2018; 8:7. [PMID: 29356993 PMCID: PMC5778088 DOI: 10.1186/s13550-018-0361-0] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2017] [Accepted: 01/10/2018] [Indexed: 01/06/2023] Open
Abstract
Background Post-therapy SPECT/CT imaging of 90Y microspheres delivered to hepatic malignancies is difficult, owing to the continuous, high-energy Bremsstrahlung spectrum emitted by 90Y. This study aimed to evaluate the utility of a commercially available software package (HybridRecon, Hermes Medical Solutions AB) which incorporates full Monte Carlo collimator modelling. Analysis of image quality was performed on both phantom and clinical images in order to ultimately provide a recommendation of an optimum reconstruction for post-therapy 90Y microsphere SPECT/CT imaging. A 3D-printed anthropomorphic liver phantom was filled with 90Y with a sphere-to-background ratio of 4:1 and imaged on a GE Discovery 670 SPECT/CT camera. Datasets were reconstructed using ordered-subsets expectation maximization (OSEM) 1–7 iterations in order to identify the optimal OSEM reconstruction (5 iterations, 15 subsets). Quantitative analysis was subsequently carried out on phantom datasets obtained using four reconstruction algorithms: the default OSEM protocol (2 iterations, 10 subsets) and the optimised OSEM protocol, both with and without full Monte Carlo collimator modelling. The quantitative metrics contrast recovery (CR) and background variability (BV) were calculated. The four algorithms were then used to retrospectively reconstruct 10 selective internal radiation therapy (SIRT) patient datasets which were subsequently blind scored for image quality by a consultant radiologist. Results The optimised OSEM reconstruction (5 iterations, 15 subsets with full MC collimator modelling) increased the CR by 42% (p < 0.001) compared to the default OSEM protocol (2 iterations, 10 subsets). The use of full Monte Carlo collimator modelling was shown to further improve CR by 14% (30 mm sphere, CR = 90%, p < 0.05). The consultant radiologist had a significant preference for the optimised OSEM over the default OSEM protocol (p < 0.001), with the optimised OSEM being the favoured reconstruction in every one of the 10 clinical cases presented. Conclusions OSEM (5 iterations, 15 subsets) with full Monte Carlo collimator modelling is quantitatively the optimal image reconstruction for post-SIRT 90Y Bremsstrahlung SPECT/CT imaging. The use of full Monte Carlo collimator modelling for correction of image-degrading effects significantly increases contrast recovery without degrading clinical image quality.
Collapse
Affiliation(s)
- Charlotte A Porter
- Radiation Physics and Protection, Churchill Hospital, Oxford University Hospitals NHS Foundation Trust, Oxford, OX3 7LE, UK.
| | - Kevin M Bradley
- Department of Radiology, Churchill Hospital, Oxford University Hospitals NHS Foundation Trust, Oxford, UK
| | - Eero T Hippeläinen
- HUS Medical Imaging Centre, Clinical Physiology and Nuclear Medicine, University of Helsinki and Helsinki University Hospital, Helsinki, Finland
| | - Matthew D Walker
- Radiation Physics and Protection, Churchill Hospital, Oxford University Hospitals NHS Foundation Trust, Oxford, OX3 7LE, UK
| | - Daniel R McGowan
- Radiation Physics and Protection, Churchill Hospital, Oxford University Hospitals NHS Foundation Trust, Oxford, OX3 7LE, UK.,Department of Oncology, University of Oxford, Old Road Campus Research Building, Oxford, UK
| |
Collapse
|
98
|
Grassi E, Fioroni F, Berenato S, Patterson N, Ferri V, Braglia L, Filice A, Versari A, Iori M, Spezi E. Effect of image registration on 3D absorbed dose calculations in 177 Lu-DOTATOC peptide receptor radionuclide therapy. Phys Med 2018; 45:177-185. [DOI: 10.1016/j.ejmp.2017.11.021] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/08/2017] [Revised: 10/18/2017] [Accepted: 11/26/2017] [Indexed: 11/29/2022] Open
|
99
|
Umeda T, Koizumi M, Fukai S, Miyaji N, Motegi K, Nakazawa S, Takiguchi T. Evaluation of bone metastatic burden by bone SPECT/CT in metastatic prostate cancer patients: defining threshold value for total bone uptake and assessment in radium-223 treated patients. Ann Nucl Med 2017; 32:105-113. [PMID: 29243019 PMCID: PMC5797193 DOI: 10.1007/s12149-017-1224-x] [Citation(s) in RCA: 51] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2017] [Accepted: 12/05/2017] [Indexed: 11/29/2022]
Abstract
Objectives To establish a new three-dimensional quantitative evaluation method for bone metastasis, we applied bone single photon emission tomography with computed tomography (SPECT/CT). The total bone uptake (TBU), which measures active bone metastatic burden, was calculated as the sum of [mean uptake obtained as standardized uptake value (SUV) above a cut-off level] × (the volume of the lesion) in the trunk using bone SPECT/CT. We studied the threshold value and utility of TBU in prostate cancer patients treated with radium-223 (Ra-223) therapy. Methods To establish the threshold value of TBU, we compared bone metastatic and non-metastatic regions in 61 prostate cancer patients with bone metastasis and 69 without. Five fixed sites in each patient were selected as evaluation points and divided into bone metastatic and non-metastatic sites. Sensitivity and specificity analysis was applied to establish the threshold level. Using the obtained threshold value, we then calculated the TBU in nine prostate cancer patients who received Ra-223 therapy, and compared the results with the bone scan index (BSI) by BONENAVI® and visual evaluation of bone scintigraphy. Results Uptake was significantly lower in non-metastatic sites in patients with bone metastasis than in patients without metastasis. Sensitivity and specificity analysis revealed SUV = 7.0 as the threshold level. There was a discrepancy between TBU and BSI change in two of the nine patients, in whom TBU change correlated with visual judgement, but BSI change did not. In two patients, BSI was nearly 0 throughout the course, but the TBU was positive and changed, although the change was not large. These results suggest that TBU may be more accurate and sensitive than BSI for quantitative evaluation of active bone metastatic burden. Conclusion We established a threshold value (SUV > 7.0) for three-dimensional TBU for evaluating active bone metastatic burden in prostate cancer patients using bone SPECT/CT. Despite the small number of patients, we expect the change in TBU could be more accurate and sensitive than the change in BSI among patients who received Ra-223.
Collapse
Affiliation(s)
- Takuro Umeda
- Department of Nuclear Medicine, Cancer Institute Hospital, 3-8-11 Ariake, Koto-ku, Tokyo, 135-8550, Japan
| | - Mitsuru Koizumi
- Department of Nuclear Medicine, Cancer Institute Hospital, 3-8-11 Ariake, Koto-ku, Tokyo, 135-8550, Japan.
| | - Shohei Fukai
- Department of Nuclear Medicine, Cancer Institute Hospital, 3-8-11 Ariake, Koto-ku, Tokyo, 135-8550, Japan
| | - Noriaki Miyaji
- Department of Nuclear Medicine, Cancer Institute Hospital, 3-8-11 Ariake, Koto-ku, Tokyo, 135-8550, Japan
| | - Kazuki Motegi
- Department of Nuclear Medicine, Cancer Institute Hospital, 3-8-11 Ariake, Koto-ku, Tokyo, 135-8550, Japan
| | - Shuto Nakazawa
- Department of Nuclear Medicine, Cancer Institute Hospital, 3-8-11 Ariake, Koto-ku, Tokyo, 135-8550, Japan
| | - Tomohiro Takiguchi
- Department of Nuclear Medicine, Cancer Institute Hospital, 3-8-11 Ariake, Koto-ku, Tokyo, 135-8550, Japan
| |
Collapse
|
100
|
Jones KM, Solnes LB, Rowe SP, Gorin MA, Sheikhbahaei S, Fung G, Frey EC, Allaf ME, Du Y, Javadi MS. Use of quantitative SPECT/CT reconstruction in 99mTc-sestamibi imaging of patients with renal masses. Ann Nucl Med 2017; 32:87-93. [PMID: 29214562 DOI: 10.1007/s12149-017-1222-z] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2017] [Accepted: 11/26/2017] [Indexed: 01/05/2023]
Abstract
OBJECTIVE Technetium-99m (99mTc)-sestamibi single-photon emission computed tomography/computed tomography (SPECT/CT) has previously been shown to allow for the accurate differentiation of benign renal oncocytomas and hybrid oncocytic/chromophobe tumors (HOCTs) apart from other malignant renal tumor histologies, with oncocytomas/HOCTs showing high uptake and renal cell carcinoma (RCC) showing low uptake based on uptake ratios from non-quantitative single-photon emission computed tomography (SPECT) reconstructions. However, in this study, several tumors fell close to the uptake ratio cutoff, likely due to limitations in conventional SPECT/CT reconstruction methods. We hypothesized that application of quantitative SPECT/CT (QSPECT) reconstruction methods developed by our group would provide more robust separation of hot and cold lesions, serving as an imaging framework on which quantitative biomarkers can be validated for evaluation of renal masses with 99mTc-sestamibi. METHODS Single-photon emission computed tomography data were reconstructed using the clinical Flash 3D reconstruction and QSPECT methods. Two blinded readers then characterized each tumor as hot or cold. Semi-quantitative uptake ratios were calculated by dividing lesion activity by background renal activity for both Flash 3D and QSPECT reconstructions. RESULTS The difference between median (mean) hot and cold tumor uptake ratios measured 0.655 (0.73) with the QSPECT method and 0.624 (0.67) with the conventional method, resulting in increased separation between hot and cold tumors. Sub-analysis of 7 lesions near the separation point showed a higher absolute difference (0.16) between QPSECT and Flash 3D mean uptake ratios compared to the remaining lesions. CONCLUSIONS Our finding of improved separation between uptake ratios of hot and cold lesions using QSPECT reconstruction lays the foundation for additional quantitative SPECT techniques such as SPECT-UV in the setting of renal 99mTc-sestamibi and other SPECT/CT exams. With robust quantitative image reconstruction and biomarker analysis, there may be an expanded role for SPECT/CT imaging in renal masses and other pathologic conditions.
Collapse
Affiliation(s)
- Krystyna M Jones
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, 601 N. Caroline St., Baltimore, MD, 21287, USA
| | - Lilja B Solnes
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, 601 N. Caroline St., Baltimore, MD, 21287, USA
| | - Steven P Rowe
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, 601 N. Caroline St., Baltimore, MD, 21287, USA.,The James Buchanan Brady Urological Institute and Department of Urology, Johns Hopkins University School of Medicine, 600 N. Wolfe St., Baltimore, MD, 21287, USA
| | - Michael A Gorin
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, 601 N. Caroline St., Baltimore, MD, 21287, USA.,The James Buchanan Brady Urological Institute and Department of Urology, Johns Hopkins University School of Medicine, 600 N. Wolfe St., Baltimore, MD, 21287, USA
| | - Sara Sheikhbahaei
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, 601 N. Caroline St., Baltimore, MD, 21287, USA
| | - George Fung
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, 601 N. Caroline St., Baltimore, MD, 21287, USA
| | - Eric C Frey
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, 601 N. Caroline St., Baltimore, MD, 21287, USA
| | - Mohamad E Allaf
- The James Buchanan Brady Urological Institute and Department of Urology, Johns Hopkins University School of Medicine, 600 N. Wolfe St., Baltimore, MD, 21287, USA
| | - Yong Du
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, 601 N. Caroline St., Baltimore, MD, 21287, USA
| | - Mehrbod S Javadi
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, 601 N. Caroline St., Baltimore, MD, 21287, USA
| |
Collapse
|