51
|
Influence of Age and Eosinophilic Esophagitis on Esophageal Distensibility in a Pediatric Cohort. Am J Gastroenterol 2017; 112:1466-1473. [PMID: 28508868 PMCID: PMC5601317 DOI: 10.1038/ajg.2017.131] [Citation(s) in RCA: 84] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/29/2016] [Accepted: 03/28/2017] [Indexed: 12/11/2022]
Abstract
OBJECTIVES Sequelae of eosinophilic esophagitis (EoE) include food impaction and esophageal stricture. Duration of inflammation is a predicted risk factor; however, complications remain unpredictable. Studies using the functional lumen imaging probe (FLIP) have demonstrated decreased distensibility of the esophagus in adult patients with EoE. As the impact of inflammation on the developing esophagus is unknown, we investigated esophageal distensibility in a pediatric cohort to determine the effect of age, ongoing inflammation, and fibrotic features on distensibility. METHODS We conducted a prospective observational study at two tertiary pediatric institutions. Subjects underwent FLIP evaluation during endoscopy to determine distensibility of the esophagus. During stepwise distension, simultaneous intrabag pressure and 16 channels of cross-sectional areas were measured. The minimal diameter at maximal esophageal distention at an intrabag pressure of 40 mm Hg was identified. Distensibility was compared between EoE and non-EoE subjects and between clinical variables within the EoE cohort. Potential confounding variables were identified. RESULTS Forty-four non-EoE and 88 EoE subjects aged 3-18 years were evaluated. Age positively correlated with esophageal distensibility in the non-EoE cohort, but this trend was not observed in the EoE population. Subjects with EoE had reduced distensibility even after adjusting for age. Active inflammation (eosinophils >15 eos/high-power field), histological lamina propria fibrosis, and various features of a fibrotic phenotype (stricture, food impaction, circumferential rings on endoscopy) were associated with decreased distensibility within the EoE cohort. FLIP was safe, feasible, and well tolerated. CONCLUSIONS These findings suggest that remodeling occurs in the pediatric EoE population, warranting early diagnosis and initiation of therapy prior to the onset of disease complications.
Collapse
|
52
|
Abstract
PURPOSE OF REVIEW This review aims to discuss the putative relationship between hiatus hernia and dysphagia. RECENT FINDINGS Proposed mechanisms of dysphagia in patients with hiatus hernia are usually difficult to identify, but recent advances in technology (high-resolution manometry with or without concomitant impedance, ambulatory pH with impedance, videofluoroscopy, and the endoluminal functional lumen imaging probe (EndoFLIP)) and methodology (inclusion of swallows of various consistencies and volumes or shifting position during the manometry protocol) can help induce symptoms and identify the underlying disorder. Chronic reflux disease is often associated with hiatus hernia and is the most common underlying etiology. Dysmotility because of impaired contractility and vigor can occur as a consequence of repeated acid exposure from the acid pocket within the hernia, and the resultant poor clearance subsequently worsens this insult. As such, dysphagia appears to be more common with increasing hiatus hernia size. Furthermore, mucosal inflammation can lead to fibrotic stricture formation and in turn obstruction. On the other hand, there appears to be a difference in the pathophysiology of smaller sliding hernias, in that those with dysphagia are more likely to have extrinsic compression at the crural diaphragm as compared to those with reflux symptoms only. Sliding hiatus hernia, especially when small, does not commonly lead to dysmotility and dysphagia; however, in those patients with symptoms, the underlying etiology can be sought with new technologies and, in particular, the reproduction of normal eating and drinking during testing.
Collapse
Affiliation(s)
- Hamish Philpott
- Department of Gastroenterology, Eastern Health, Melbourne, Australia.
- Department of Gastroenterology, Box Hill Hospital, 3 Arnold St Box Hill, Melbourne, 3128, Australia.
| | - Rami Sweis
- Department of Gastroenterology, University College London, London, UK
| |
Collapse
|
53
|
Ahuja NK, Agnihotri A, Lynch KL, Hoo-Fatt D, Onyimba F, McKnight M, Okeke FC, Garcia P, Dhalla S, Stein E, Pasricha PJ, Clarke JO. Esophageal distensibility measurement: impact on clinical management and procedure length. Dis Esophagus 2017; 30:1-8. [PMID: 28575249 DOI: 10.1093/dote/dox038] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/29/2016] [Accepted: 03/29/2017] [Indexed: 12/11/2022]
Abstract
Luminal distensibility measurement has demonstrated relevance to various disease processes, though its effects on clinical decision-making have been less well understood. This study aims to characterize the clinical impact of impedance planimetry measurement as well as the learning curve associated with its use in the esophagus. A single provider performed distensibility measurement in conjunction with upper endoscopy for a variety of clinical indications with the functional lumen imaging probe (FLIP) over a period of 21 months. Procedural data were prospectively collected and, along with medical records, retrospectively reviewed. Seventy-three procedures (70 patients) underwent esophageal distensibility measurement over the timeline of this study. The most common procedural indications were known or suspected achalasia (32.9%), dysphagia with connective tissue disease (13.7%), eosinophilic esophagitis (12.3%), and dysphagia with prior fundoplication (9.6%). FLIP results independently led to a change in management in 29 (39.7%) cases and supported a change in management in an additional 15 (20.5%) cases. The most common change in management was a new or amended therapeutic procedure (79.5%). Procedural time added by distensibility measurement was greater among earlier cases than among later cases. The median time added overall was 5 minutes and 46 seconds. Procedural time added varied significantly by procedural indication, but changes in management did not. Distensibility measurement added meaningful diagnostic information that impacted therapeutic decision-making in the majority of cases in which it was performed. Procedural time added by this modality is typically modest and decreases with experience.
Collapse
Affiliation(s)
- N K Ahuja
- Division of Gastroenterology and Hepatology
| | - A Agnihotri
- Department of Internal Medicine, Johns Hopkins Bayview Medical Center, The Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | - K L Lynch
- Division of Gastroenterology and Hepatology
| | - D Hoo-Fatt
- Department of Internal Medicine, Johns Hopkins Bayview Medical Center, The Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | - F Onyimba
- Division of Gastroenterology and Hepatology
| | - M McKnight
- Division of Gastroenterology and Hepatology
| | - F C Okeke
- Department of Internal Medicine, Johns Hopkins Bayview Medical Center, The Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | - P Garcia
- Division of Gastroenterology and Hepatology
| | - S Dhalla
- Division of Gastroenterology and Hepatology
| | - E Stein
- Division of Gastroenterology and Hepatology
| | | | - J O Clarke
- Division of Gastroenterology and Hepatology
| |
Collapse
|
54
|
Fynne L, Liao D, Aksglaede K, Lottrup C, Gregersen H, Bjerregaard NC, Drewes AM, Krogh K. Esophagogastric junction in systemic sclerosis: A study with the functional lumen imaging probe. Neurogastroenterol Motil 2017; 29. [PMID: 28466556 DOI: 10.1111/nmo.13073] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/03/2016] [Accepted: 02/24/2017] [Indexed: 12/11/2022]
Abstract
BACKGROUND Fibrosis and atrophy of esophageal smooth muscle cells cause gastro-esophageal reflux and dysphagia in most patients with systemic sclerosis (SSc). Recent studies indicate that distensibility of the esophagogastric junction (EGJ), assessed with the Functional Lumen Imaging Probe (FLIP) may be a more sensitive and accurate measure of sphincter function than manometry. We aim to describe and compare distension parameters of the EGJ in a well-characterized group of patients with SSc. METHOD Twelve patients with SSc reporting reflux or dysphagia (11 women, median age 53 [range 35-72], duration of disease: 1-20 years) were investigated using distensibility testing of the EGJ. Patients were compared with 11 healthy volunteers (HV) (10 women, median age 53 [range 40-68]). The pressure and minimum diameter along the EGJ during ramp distension were used for distensibility analysis. KEY RESULTS Patients with SSc had significantly lower EGJ yield pressure (median: 4.0 mm Hg [Inter Quartile Range (IQR): 2.8-7.7]) than HV (median: 6.2 mm Hg [IQR: 9.4-26]) (P=.007). Likewise, the pressure-strain elastic modulus was lower in SSc patients (median 1.73 kPa [IQR: 1.16-2.15]) than in HV (median 2.41 kPa [IQR: 1.85-2.67]) (P=.03), indicating the reduced resistance to distension in SSc patient. CONCLUSION & INFERENCES Patients with SSc and symptoms of reflux and dysphagia have significantly reduced resistance to distension of the EGJ.
Collapse
Affiliation(s)
- L Fynne
- Neurogastroenterology Unit, Department of Hepatology and Gastroenterology, Aarhus University Hospital, Aarhus, Denmark
| | - D Liao
- GIOME Academia, Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
| | - K Aksglaede
- Department of Surgery, Aarhus University Hospital, Aarhus, Denmark
| | - C Lottrup
- Mech-Sense, Department of Gastroenterology and Hepatology & Clinical Institute, Aalborg University Hospital, Aalborg, Denmark
| | - H Gregersen
- GIOME, Department of Surgery, Prince of Wales Hospital and Chinese University of Hong Kong, Shatin, Hong Kong
| | - N C Bjerregaard
- Department of Surgery, Aarhus University Hospital, Aarhus, Denmark
| | - A M Drewes
- Mech-Sense, Department of Gastroenterology and Hepatology & Clinical Institute, Aalborg University Hospital, Aalborg, Denmark
| | - K Krogh
- Neurogastroenterology Unit, Department of Hepatology and Gastroenterology, Aarhus University Hospital, Aarhus, Denmark
| |
Collapse
|
55
|
Ata-Lawenko RM, Lee YY. Emerging Roles of the Endolumenal Functional Lumen Imaging Probe in Gastrointestinal Motility Disorders. J Neurogastroenterol Motil 2017; 23:164-170. [PMID: 28013295 PMCID: PMC5383111 DOI: 10.5056/jnm16171] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/13/2016] [Accepted: 11/20/2016] [Indexed: 02/06/2023] Open
Abstract
Gastrointestinal sphincters play a vital role in gut function and motility by separating the gut into functional segments. Traditionally, function of sphincters including the esophagogastric junction is studied using endoscopy and manometry. However, due to its dynamic biomechanical properties, data on distensibility and compliance may provide a more accurate representation of the sphincter function. The endolumenal functional lumen imaging probe (EndoFLIP) system uses a multi-detector impedance planimetry system to provide data on tissue distensibility and geometric changes in the sphincter as measured through resistance to volumetric distention with real-time images. With the advent of EndoFLIP studies, esophagogastric junction dysfunction and other disorders of the stomach and bowels may be better evaluated. It may be utilized as a tool in predicting effectiveness of endoscopic and surgical treatments as well as patient outcomes.
Collapse
Affiliation(s)
- Rona M Ata-Lawenko
- Section of Gastroenterology, De La Salle Health Sciences Institute, Dasmarinas City, Cavite, Philippines
| | - Yeong Yeh Lee
- School of Medical Sciences, Universiti Sains Malaysia, Kubang Kerian, Kota Bahru, Kelantan, Malaysia
| |
Collapse
|
56
|
Pitt KA, Mayhew PD, Barter L, Pollard R, Kass PH, Marks SL. Consistency and effect of body position change on measurement of upper and lower esophageal sphincter geometry using impedance planimetry in a canine model. Dis Esophagus 2017; 30:1-7. [PMID: 28375475 DOI: 10.1093/dote/dow031] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/05/2015] [Accepted: 11/29/2016] [Indexed: 12/11/2022]
Abstract
The EndoFLIP (Endolumenal Functional Lumen Imaging Probe, Crospon Inc, Galway, Ireland) device uses the technique of impedance planimetry to evaluate dimensions and distensibility of the upper and lower esophageal sphincter. The null hypotheses for this study were that EndoFLIP variables would be stable between anesthestic episodes and would not be affected by body position when evaluating the upper and lower esophageal sphincters in healthy dogs. During each of three consecutive general anesthesia episodes administered to eight healthy adult research colony dogs with a standardized protocol, the EndoFLIP catheter was positioned to measure cross-sectional area, intrabag pressure, upper and lower esophageal sphincter length at two different balloon fill volumes (30 and 40 mL) and two body positions (lateral and dorsal recumbency). From these measured variables, a distensibility index was also calculated. Mixed effect analysis of variance was used to evaluate the fixed marginal and interaction effects of anesthesia episode, body position, and balloon volume on measured and calculated variables. For the upper esophageal sphincter significant interactions were present between anesthetic episode and body position for all variables except intrabag pressure; adjusting for body position significant differences were present between anesthetic episodes for all variables except distensibility index; adjusting for anesthetic episode cross-sectional area, intrabag pressure, upper esophageal sphincter length and distensibility index were all affected by body position. For the lower esophageal sphincter distensibility index was the only variable where a significant interaction between anesthesia episode and body position occurred; cross-sectional area, intrabag pressure, and lower esophageal length were not significantly affected by anesthesia episode when adjusting for body position; distensibility index was the only variable significantly affected by body position. Measurements of the geometry of the lower esophageal sphincter as measured by the EndoFLIP device were consistent under conditions of general anesthesia. Similar measurements taken at the upper esophageal sphincter displayed greater variability between anesthetic episodes and were affected to a greater extent by body position. Body position should be standardized in studies using the EndoFLIP to assess geometric and functional characteristics of the upper and lower esophageal sphincters.
Collapse
Affiliation(s)
- K A Pitt
- From the Departments of Surgical and Radiological Sciences
| | - P D Mayhew
- From the Departments of Surgical and Radiological Sciences
| | - L Barter
- From the Departments of Surgical and Radiological Sciences
| | - R Pollard
- From the Departments of Surgical and Radiological Sciences
| | - P H Kass
- Population Health and Reproduction
| | - S L Marks
- Medicine and Epidemiology, School of Veterinary Medicine, University of California-Davis, Davis, California, USA
| |
Collapse
|
57
|
Carlson DA, Hirano I. Application of the Functional Lumen Imaging Probe to Esophageal Disorders. ACTA ACUST UNITED AC 2017; 15:10-25. [PMID: 28265971 DOI: 10.1007/s11938-017-0116-4] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
OPINION STATEMENT The functional luminal imaging probe (FLIP) provides a novel method to evaluate esophageal physiology and function in both health and disease. FLIP enables assessment of a previously underexplored component of esophageal function, distensibility, by utilizing high-resolution impedance planimetry to evaluate the relationship of the esophageal luminal geometry with pressure during controlled volumetric distension. Recent studies have described the potential utility of FLIP to evaluate the severity and effectiveness of therapy for esophageal diseases including achalasia, gastroesophageal reflux disease, and eosinophilic esophagitis. This review summarizes these emerging clinical applications of FLIP in the evaluation and management of esophageal diseases.
Collapse
Affiliation(s)
- Dustin A Carlson
- Department of Medicine, Division of Gastroenterology and Hepatology, Northwestern University Feinberg School of Medicine, 676 St Clair St, Suite 1400, Chicago, IL, 60611-2951, USA.
| | - Ikuo Hirano
- Department of Medicine, Division of Gastroenterology and Hepatology, Northwestern University Feinberg School of Medicine, 676 St Clair St, Suite 1400, Chicago, IL, 60611-2951, USA.
| |
Collapse
|
58
|
Hirano I, Pandolfino JE, Boeckxstaens GE. Functional Lumen Imaging Probe for the Management of Esophageal Disorders: Expert Review From the Clinical Practice Updates Committee of the AGA Institute. Clin Gastroenterol Hepatol 2017; 15:325-334. [PMID: 28212976 PMCID: PMC5757507 DOI: 10.1016/j.cgh.2016.10.022] [Citation(s) in RCA: 138] [Impact Index Per Article: 19.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/09/2016] [Revised: 10/03/2016] [Accepted: 10/16/2016] [Indexed: 02/06/2023]
Abstract
The functional luminal imaging probe is a Food and Drug Administration-approved measurement tool used to measure simultaneous pressure and diameter to guide management of various upper gastrointestinal disorders. Additionally, this tool is also approved to guide therapy during bariatric procedures and specialized esophageal surgery. Although it has been commercially available since 2009 as the endolumenal functional lumen imaging probe (EndoFLIP), the functional luminal imaging probe has had limited penetrance into clinical settings outside of specialized centers. This is primarily because of a paucity of data supporting its utility in general practice and a lack of standardized protocols and data analysis methodology. However, data are accumulating that are providing guidance regarding emerging applications in the evaluation and management of foregut disorders. This clinical practice update describes the technique and reviews potential indications in achalasia, eosinophilic esophagitis, and gastroesophgeal reflux disease. Best Practice Advice 1: Clinicians should not make a diagnosis or treatment decision based on functional lumen imaging probe (FLIP) assessment alone. Best Practice Advice 2: FLIP assessment is a complementary tool to assess esophagogastric junction opening dynamics and the stiffness of the esophageal wall. Best Practice Advice 3: Utilization should follow distinct protocols and analysis paradigms based on the disease state of interest. Best Practice Advice 4: Clinicians should not utilize FLIP in routine diagnostic assessments of gastroesophageal reflux disease. Best Practice Advice 5: FLIP should not be used to diagnose eosinophilic esophagitis but may have a role in severity assessment and therapeutic monitoring.
Collapse
Affiliation(s)
- Ikuo Hirano
- Department of Medicine, Division of Gastroenterology and Hepatology, Northwestern University Feinberg School of Medicine, Chicago, Illinois
| | - John E Pandolfino
- Department of Medicine, Division of Gastroenterology and Hepatology, Northwestern University Feinberg School of Medicine, Chicago, Illinois
| | - Guy E Boeckxstaens
- Department of Gastroenterology, Translational Research Center for Gastrointestinal Disorders, University Hospital Leuven, Catholic University of Leuven, Leuven, Belgium
| |
Collapse
|
59
|
Chen JW, Rubenstein JH. Esophagogastric junction distensibility assessed using the functional lumen imaging probe. World J Gastroenterol 2017; 23:1289-1297. [PMID: 28275309 PMCID: PMC5323454 DOI: 10.3748/wjg.v23.i7.1289] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/08/2016] [Revised: 12/08/2016] [Accepted: 12/21/2016] [Indexed: 02/06/2023] Open
Abstract
AIM To assess reference values in the literature for esophageal distensibility and cross-sectional area in healthy and diseased subjects measured by the functional lumen imaging probe (FLIP).
METHODS Systematic search and review of articles in Medline and Embase pertaining to the use of FLIP in the esophagus was conducted in accordance with the PRISMA guidelines. Cross-sectional area and distensibility at the esophagogastric junction (EGJ) were abstracted for normal subjects, achalasia, and gastroesophageal reflux disease (GERD) patients, stratified by balloon length and volume of inflation.
RESULTS Six achalasia studies (n = 154), 3 GERD (n = 52), and 5 studies including healthy controls (n = 98) were included in the systematic review. Normative data varied widely amongst studies of healthy volunteers. In contrast, studies in achalasia patients uniformly demonstrated low point estimates in distensibility ≤ 1.6 mm2/mmHg prior to treatment that increased to ≥ 3.4 mm2/mmHg following treatment at 40mL bag volume. In GERD patients, distensibility fell to the range of untreated achalasia (≤ 2.85 mm2/mmHg) following fundoplication.
CONCLUSION FLIP may be a useful tool in assessment of treatment efficacy in achalasia. The drastic drop in EGJ distensibility after fundoplication suggests that FLIP measurements need to be interpreted in the context of esophageal body motility and highlights the importance of pre-operative screening for dysmotility. Future studies using standardized FLIP protocol and balloon size are needed.
Collapse
|
60
|
Abstract
The utilization of impedance technology has enhanced our understanding and assessment of esophageal dysmotility. Esophageal high-resolution manometry (HRM) catheters incorporated with multiple impedance electrodes help assess esophageal bolus transit, and the combination is termed high-resolution impedance manometry (HRIM). Novel metrics have been developed with HRIM-including esophageal impedance integral ratio, bolus flow time, nadir impedance pressure, and impedance bolus height-that augments the assessment of esophageal bolus transit. Automated impedance-manometry (AIM) analysis has enhanced understanding of the relationship between bolus transit and pressure phenomena. Impedance-based metrics have improved understanding of the dynamics of esophageal bolus transit into four distinct phases, may correlate with symptomatic burden, and can assess the adequacy of therapy for achalasia. An extension of the use of impedance involves impedance planimetry and the functional lumen imaging probe (FLIP), which assesses esophageal biophysical properties and distensibility, and could detect patterns of esophageal contractility not seen on HRM. Impedance technology, therefore, has a significant impact on esophageal function testing in the present day.
Collapse
Affiliation(s)
- Amit Patel
- Division of Gastroenterology, Duke University School of Medicine and the Durham Veterans Affairs Medical Center, 704 15th Street no. 221, Durham, NC, 27705, USA
| | - C Prakash Gyawali
- Division of Gastroenterology, Washington University School of Medicine, 660 South Euclid Ave., Campus Box 8124, Saint Louis, MO, 63110, USA.
| |
Collapse
|
61
|
Abstract
PURPOSE OF REVIEW Impedance planimetry measures tissue wall distensibility as a function of pressure and cross-sectional area. Recent interest in this technique's relevance to the gastrointestinal tract has been accelerated by the availability of the functional lumen imaging probe, a catheter-based system that dynamically quantitates these biomechanical properties. Herein, we review the device's particular utility in the setting of esophageal pathology, including processes affecting the esophageal body as well as the upper and lower esophageal sphincters. RECENT FINDINGS An expanding suite of disease-specific indications for impedance planimetry includes achalasia, gastroesophageal reflux disease, and eosinophilic esophagitis. The technique has also demonstrated a role in the intraoperative guidance of therapy and in the definition of hitherto unrecognized patterns of esophageal dysmotility. Device-specific technology remains in active evolution, which, in conjunction with progressively larger datasets, sets the stage for broader clinical applicability in the near future.
Collapse
Affiliation(s)
- Nitin K Ahuja
- Division of Gastroenterology and Hepatology, Johns Hopkins University School of Medicine, 1800 Orleans St, Baltimore, MD, 21287, USA
| | - John O Clarke
- Division of Gastroenterology and Hepatology, Stanford University School of Medicine, 300 Pasteur Drive, Room H0206B, MC: 5244, Stanford, CA, 94305, USA.
| |
Collapse
|
62
|
Nikaki K, Ooi JLS, Sifrim D. Chicago Classification of Esophageal Motility Disorders: Applications and Limits in Adults and Pediatric Patients with Esophageal Symptoms. Curr Gastroenterol Rep 2016; 18:59. [PMID: 27738966 DOI: 10.1007/s11894-016-0532-y] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
The Chicago classification (CC) is most valued for its systematic approach to esophageal disorders and great impact in unifying practice for esophageal manometric studies. In view of the ever-growing wealth of knowledge and experience gained by the expanding use of high-resolution manometry (HRM) in various clinical scenarios, the CC is regularly updated. Its clinical impact and ability to predict clinical outcome, both in adults and pediatrics, will be further promoted by recognizing its current limitations, incorporating new metrics in its diagnostic algorithms and adjusting the HRM protocols based on the clinical question posed. Herein, we discuss the current limitations of the CC and highlight some areas of improvement for the future.
Collapse
Affiliation(s)
- Kornilia Nikaki
- Barts and The London School of Medicine and Dentistry, Queen Mary University of London, 26 Ashfield Street, E1 2AJ, London, UK
| | - Joanne Li Shen Ooi
- Barts and The London School of Medicine and Dentistry, Queen Mary University of London, 26 Ashfield Street, E1 2AJ, London, UK
| | - Daniel Sifrim
- Barts and The London School of Medicine and Dentistry, Queen Mary University of London, 26 Ashfield Street, E1 2AJ, London, UK.
| |
Collapse
|
63
|
|
64
|
Savarino E, Ottonello A, Tolone S, Bartolo O, Baeg MK, Farjah F, Kuribayashi S, Shetler KP, Lottrup C, Stein E. Novel insights into esophageal diagnostic procedures. Ann N Y Acad Sci 2016; 1380:162-177. [PMID: 27681220 DOI: 10.1111/nyas.13255] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2016] [Revised: 08/12/2016] [Accepted: 08/22/2016] [Indexed: 12/14/2022]
Abstract
The 21st century offers new advances in diagnostic procedures and protocols in the management of esophageal diseases. This review highlights the most recent advances in esophageal diagnostic technologies, including clinical applications of novel endoscopic devices, such as ultrathin endoscopy and confocal laser endomicroscopy for diagnosis and management of Barrett's esophagus; novel parameters and protocols in high-resolution esophageal manometry for the identification and better classification of motility abnormalities; innovative connections between esophageal motility disorder diagnosis and detection of gastroesophageal reflux disease (GERD); impedance-pH testing for detecting the various GERD phenotypes; performance of distensibility testing for better pathophysiological knowledge of the esophagus and other gastrointestinal abnormalities; and a modern view of positron emission tomography scanning in metastatic disease detection in the era of accountability as a model for examining other new technologies. We now have better tools than ever for the detection of esophageal diseases and disorders, and emerging data are helping to define how well these tools change management and provide value to clinicians. This review features novel insights from multidisciplinary perspectives, including both surgical and medical perspectives, into these new tools, and it offers guidance on the use of novel technologies in clinical practice and future directions for research.
Collapse
Affiliation(s)
- Edoardo Savarino
- Division of Gastroenterology, Department of Surgery, Oncology and Gastroenterology, University of Padua, Padua, Italy.
| | - Andrea Ottonello
- Department of Surgical and Diagnostic Integrated Sciences, University of Genoa, Genoa, Italy
| | - Salvatore Tolone
- Division of General and Bariatric Surgery, Department of Surgery, Second University of Naples, Naples, Italy
| | - Ottavia Bartolo
- Division of Gastroenterology, Department of Surgery, Oncology and Gastroenterology, University of Padua, Padua, Italy
| | - Myong Ki Baeg
- Division of Gastroenterology, Department of Internal Medicine, Catholic Kwandong University College of Medicine, International St. Mary's Hospital, Incheon, South Korea
| | - Farhood Farjah
- Division of Cardiothoracic Surgery, Surgical Outcomes Research Center, University of Washington, Seattle, Washington
| | - Shiko Kuribayashi
- Department of Gastroenterology and Hepatology, Gunma University Hospital, Maebashi, Japan
| | - Katerina P Shetler
- Division of Gastroenterology, Palo Alto Medical Foundation, Mountain View, California
| | - Christian Lottrup
- Department of Gastroenterology and Hepatology, Mech-Sense, Aalborg University Hospital, Aalborg, Denmark.,Department of Medicine, North Jutland Regional Hospital, Hjørring, Denmark
| | - Ellen Stein
- Division of Gastroenterology and Hepatology, Department of Medicine, Johns Hopkins University, Baltimore, Maryland
| |
Collapse
|
65
|
Brock C, McCallum RW, Gyawali CP, Farmer AD, Frøkjaer JB, McMahon BP, Drewes AM. Neurophysiology and new techniques to assess esophageal sensory function: an update. Ann N Y Acad Sci 2016; 1380:78-90. [DOI: 10.1111/nyas.13175] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2016] [Revised: 06/10/2016] [Accepted: 06/15/2016] [Indexed: 12/19/2022]
Affiliation(s)
- Christina Brock
- Mech-Sense, Department of Gastroenterology and Hepatology, Aalborg University Hospital and Clinical Institute; Aalborg University; Aalborg Denmark
| | - Richard W. McCallum
- Department of Internal Medicine; Texas Tech University Health Sciences Center; El Paso Texas
| | - C. Prakash Gyawali
- Division of Gastroenterology; Washington University School of Medicine; St. Louis Missouri
| | - Adam D. Farmer
- Mech-Sense, Department of Gastroenterology and Hepatology, Aalborg University Hospital and Clinical Institute; Aalborg University; Aalborg Denmark
- Centre for Digestive Diseases, Blizard Institute, Wingate Institute of Neurogastroenterology, Barts and the London School of Medicine and Dentistry; Queen Mary University of London; London United Kingdom
- Department of Gastroenterology; University Hospitals of North Midlands; Stoke on Trent United Kingdom
| | - Jens Brøndum Frøkjaer
- Mech-Sense, Department of Radiology, Aalborg University Hospital and Clinical Institute; Aalborg University; Aalborg Denmark
| | - Barry P. McMahon
- Department of Medical Physics and Clinical Engineering; Tallaght Hospital and Trinity College; Dublin Ireland
| | - Asbjørn Mohr Drewes
- Mech-Sense, Department of Gastroenterology and Hepatology, Aalborg University Hospital and Clinical Institute; Aalborg University; Aalborg Denmark
| |
Collapse
|
66
|
Miller L, Vegesna A, Ruggieri M, Braverman A. Normal and abnormal physiology, pharmacology, and anatomy of the gastroesophageal junction high-pressure zone. Ann N Y Acad Sci 2016; 1380:48-57. [PMID: 27467321 DOI: 10.1111/nyas.13168] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2016] [Revised: 06/02/2016] [Accepted: 06/07/2016] [Indexed: 12/31/2022]
Abstract
The high-pressure zone of the gastroesophageal junction acts as a multifunctional valve that comprises different groups of smooth muscles located in the distal esophagus and the proximal stomach, in addition to the extrinsic crural diaphragm, composed of skeletal muscle. In this review article, we evaluate the current literature with respect to human subjects, discussing the anatomic locations and physiologic and pharmacologic processes controlling these muscles. These muscles work individually and as a group to prevent reflux of gastric contents while allowing anterograde passage of food and liquid and retrograde passage of gas. We also reviewed new findings with respect to abnormalities that are permissive of reflux of gastric contents into the esophagus, which may lead to gastroesophageal reflux disease.
Collapse
Affiliation(s)
- Larry Miller
- Department of Medicine (Gastroenterology), The Feinstein Institute for Medical Research, Northwell Health, Manhasset, New York.
| | - Anil Vegesna
- Department of Medicine (Gastroenterology), The Feinstein Institute for Medical Research, Northwell Health, Manhasset, New York
| | - Michael Ruggieri
- Department of Anatomy and Cell Biology, Temple University School of Medicine, Philadelphia, Pennsylvania
| | - Alan Braverman
- Department of Anatomy and Cell Biology, Temple University School of Medicine, Philadelphia, Pennsylvania
| |
Collapse
|
67
|
Mayhew PD, Pitt KA, Steffey MA, Culp WTN, Kass PH, Marks SL. Effect of changes in intra-abdominal pressure on diameter, cross-sectional area, and distensibility of the lower esophageal sphincter of healthy dogs as determined by use of an endoscopic functional luminal imaging probe. Am J Vet Res 2016; 77:799-804. [PMID: 27463542 DOI: 10.2460/ajvr.77.8.799] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
OBJECTIVE To evaluate the effect of intra-abdominal pressure (IAP) on morphology and compliance of the lower esophageal sphincter (LES) by use of impedance planimetry in healthy dogs and to quantify the effect of changes in IAP. ANIMALS 7 healthy, purpose-bred sexually intact male hound-cross dogs. PROCEDURES Dogs were anesthetized, and cross-sectional area (CSA), minimal diameter (MD), LES length, LES volume, and distensibility index (DI) of the LES were evaluated by use of an endoscopic functional luminal imaging probe. For each dog, measurements were obtained before (baseline) and after creation of a pneumoperitoneum at an IAP of 4, 8, and 15 mm Hg. Order of the IAPs was determined by use of a randomization software program. RESULTS CSA and MD at 4 and 8 mm Hg were not significantly different from baseline measurements; however, CSA and MD at 15 mm Hg were both significantly greater than baseline measurements. The LES length and LES volume did not differ significantly from baseline measurements at any IAP. The DI differed inconsistently from the baseline measurement but was not substantially affected by IAP. CONCLUSIONS AND CLINICAL RELEVANCE Pneumoperitoneum created with an IAP of 4 or 8 mm Hg did not significantly alter LES morphology in healthy dogs. Pneumoperitoneum at an IAP of 15 mm Hg caused a significant increase in CSA and MD of the LES. Compliance of the LES as measured by the DI was not greatly altered by pneumoperitoneum at an IAP of up to 15 mm Hg.
Collapse
|
68
|
Abstract
PURPOSE OF REVIEW The aim of this review is to summarize use of the functional lumen imaging probe (FLIP) for the evaluation and management of esophageal diseases. RECENT FINDINGS The FLIP utilizes high-resolution impedance planimetry to evaluate the functional geometry and cross-sectional area/pressure relationship (i.e. distensibility) of the esophageal sphincters and body. Recent studies have reported the potential utility of FLIP to evaluate esophageal diseases, such as achalasia, gastroesophageal reflux disease, and eosinophilic esophagitis. SUMMARY Esophageal distensibility measures provided by the FLIP will add to our understanding of the contribution of esophageal mechanical properties to esophageal symptoms and function. Application of the FLIP in clinical practice complements the diagnostic evaluation of esophageal function and may also be a valuable tool to help direct and target clinical management of esophageal diseases.
Collapse
|
69
|
Lottrup C, McMahon BP, Ejstrud P, Ostapiuk MA, Funch-Jensen P, Drewes AM. Esophagogastric junction distensibility in hiatus hernia. Dis Esophagus 2016; 29:463-71. [PMID: 25789842 DOI: 10.1111/dote.12344] [Citation(s) in RCA: 42] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Hiatus hernia is known to be an important risk factor for developing gastroesophageal reflux disease. We aimed to use the endoscopic functional lumen imaging probe (EndoFLIP) to evaluate the functional properties of the esophagogastric junction. EndoFLIP assessments were made in 30 patients with hiatus hernia and Barrett's esophagus, and in 14 healthy controls. The EndoFLIP was placed straddling the esophagogastric junction and the bag distended stepwise to 50 mL. Cross-sectional areas of the bag and intra-bag pressures were recorded continuously. Measurements were made in the separate sphincter components and hiatus hernia cavity. EndoFLIP measured functional aspects such as sphincter distensibility and pressure of all esophagogastric junction components and visualized all hiatus hernia present at endoscopy. The lower esophageal sphincter in hiatus hernia patients had a lower pressure (e.g. 47.7 ± 13.0 vs. 61.4 ± 19.2 mm Hg at 50-mL distension volume) and was more distensible (all P < 0.001) than the common esophagogastric junction in controls. In hiatus hernia patients, the crural diaphragm had a lower pressure (e.g. 29.6 ± 10.1 vs. 47.7 ± 13.0 mm Hg at 50-mL distension volume) and was more distensible (all P < 0.001) than the lower esophageal sphincter. There was a significant association between symptom scores in patients and EndoFLIP assessment. Conclusively, EndoFLIP was a useful tool. To evaluate the presence of a hiatus hernia and to measure the functional properties of the esophagogastric junction. Furthermore, EndoFLIP distinguished the separate esophagogastric junction components in hiatus hernia patients, and may help us understand the biomechanics of the esophagogastric junction and the mechanisms behind hiatal herniation.
Collapse
Affiliation(s)
- C Lottrup
- Mech-Sense, Department of Gastroenterology and Hepatology, Aalborg University Hospital, Aalborg, Denmark
| | - B P McMahon
- Department of Medical Physics and Clinical Engineering, Tallaght Hospital and Trinity College, Dublin, Ireland
| | - P Ejstrud
- Department of Surgery, Aalborg University Hospital, Aalborg, Denmark
| | - M A Ostapiuk
- Department of Surgery, Aalborg University Hospital, Aalborg, Denmark
| | - P Funch-Jensen
- Institute of Clinical Medicine, Aarhus University Hospital, Aarhus, Denmark
| | - A M Drewes
- Mech-Sense, Department of Gastroenterology and Hepatology, Aalborg University Hospital, Aalborg, Denmark
| |
Collapse
|
70
|
Snape WJ, Lin MS, Agarwal N, Shaw RE. Evaluation of the pylorus with concurrent intraluminal pressure and EndoFLIP in patients with nausea and vomiting. Neurogastroenterol Motil 2016; 28:758-64. [PMID: 26813266 DOI: 10.1111/nmo.12772] [Citation(s) in RCA: 75] [Impact Index Per Article: 9.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/09/2015] [Accepted: 12/17/2015] [Indexed: 12/25/2022]
Abstract
BACKGROUND Nausea and vomiting occurs in gastroparesis due to diabetes mellitus or unknown causes. The aim of this study was to compare (i) pyloric distensibility to pyloric manometric pressure in patients with nausea and vomiting and (ii) to correlate distensibility with delays in gastric emptying. METHODS Sleeve manometry and EndoFLIP were performed sequentially during the same endoscopy on 114 patients with nausea and vomiting (47 with diabetes mellitus and 67 with idiopathic cause) after a standardized gastric emptying study. The sleeve manometer was positioned fluoroscopically, and the EndoFLIP was placed endoscopically. Manometric pressure using a water-perfused catheter and distensibility using an EndoFLIP filled with 40 cc of saline were measured from the pylorus. KEY RESULTS The basal pyloric pressure was elevated (>10 mmHg) in 34 patients and was normal in 80 patients. The basal and peak pressures were similar in patient with normal and delayed gastric emptying (p > 0.05). There was a significant decrease in distensibility (8.0 ± 1.0 mm(2) /mmHg) in patients with gastric retention (>20% at 4 h) compared with patients (12.4 ± 1.4 mm(2) /mmHg) (p < 0.01) with normal gastric retention (<10%). Pressure measurements from the sleeve manometer and the EndoFLIP correlated (r = 0.29) (p < 0.002), and increased EndoFLIP balloon pressure (19.4 ± 1.4 mmHg) (p < 0.01) was associated with a severe delay in gastric emptying. CONCLUSIONS & INFERENCES Elevated basal pyloric pressure occurs in 42% of patients with nausea and vomiting and delayed emptying. Decreased pyloric distensibility occurs with nausea, vomiting, and delayed gastric emptying. The EndoFLIP is a useful tool in the evaluation of pyloric function in symptomatic patients.
Collapse
Affiliation(s)
- W J Snape
- Neurogastroenterology and Motility, California Pacific Medical Center, San Francisco, CA, USA
| | - M S Lin
- Neurogastroenterology and Motility, California Pacific Medical Center, San Francisco, CA, USA
| | - N Agarwal
- Neurogastroenterology and Motility, California Pacific Medical Center, San Francisco, CA, USA
| | - R E Shaw
- Neurogastroenterology and Motility, California Pacific Medical Center, San Francisco, CA, USA
| |
Collapse
|
71
|
DeHaan RK, Davila D, Frelich MJ, Gould JC. Esophagogastric junction distensibility is greater following Toupet compared to Nissen fundoplication. Surg Endosc 2016; 31:193-198. [DOI: 10.1007/s00464-016-4956-0] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2016] [Accepted: 04/18/2016] [Indexed: 01/16/2023]
|
72
|
Reynolds JL, Zehetner J, Shiraga S, Lipham JC, Katkhouda N. Intraoperative assessment of the effects of laparoscopic sleeve gastrectomy on the distensibility of the lower esophageal sphincter using impedance planimetry. Surg Endosc 2016; 30:4904-4909. [PMID: 27071928 DOI: 10.1007/s00464-016-4829-6] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2015] [Accepted: 02/09/2016] [Indexed: 02/07/2023]
Abstract
BACKGROUND Laparoscopic sleeve gastrectomy (LSG) has emerged as an effective weight-loss procedure for morbid obesity that is also effective for treating comorbidities such as diabetes. However, it has been associated with the development of GERD postoperatively. The pathophysiology of post-LSG GERD is unknown, and current studies have shown conflicting results. The aim of our study is to shed light on this issue by investigating the effect of LSG on the lower esophageal sphincter (LES) function and the relationship of LES function to GERD symptoms. METHODS A prospective study of patients undergoing LSG from 10/2013 to 8/2014 at a single academic tertiary referral center was carried out. Patients undergoing a concomitant procedure such as hiatal hernia repair or laparoscopic gastric band removal were excluded. Distensibility of the LES was measured after pneumoperitoneum and after LSG. Baseline GERD-HRQL was obtained with follow-up GERD-HRQL and weight at 3 and 6 months. The primary outcomes measured were LES distensibility and GERD-HRQL scores after LSG. Our secondary outcome was a correlation between LES distensibility and GERD-HRQL scores after LSG. RESULTS Fifteen subjects were enrolled (5M/10F). Mean age was 51 years (30-71 years), and mean BMI 45 kg/m2 (30-58). We were able to obtain follow-up data for all patients at 3 months. Mean LES distensibility increased from 1.2 before LSG to 2.2 after LSG (p = 0.017). Median GERD-HRQL was 0 before LSG and remained essentially negative at 1 and 0 (3 and 6 months postoperatively, respectively). Three (27 %) of the patients had de novo GERD at 3 months following LSG. One (25 %) patient had remission of GERD. There was no correlation between LES distensibility and GERD symptoms. CONCLUSION While LSG weakens the LES immediately, it does not predictably affect postoperative GERD symptoms; therefore, distensibility is not the only factor affecting development of postoperative GERD, confirming the multifactorial nature of post-LSG GERD.
Collapse
Affiliation(s)
- Jessica L Reynolds
- Department of General Surgery, Keck Medical Center, University of Southern California, 1510 San Pablo Street, Suite 514, Los Angeles, CA, 90033, USA
| | - Joerg Zehetner
- Department of General Surgery, Keck Medical Center, University of Southern California, 1510 San Pablo Street, Suite 514, Los Angeles, CA, 90033, USA
| | | | - John C Lipham
- Department of General Surgery, Keck Medical Center, University of Southern California, 1510 San Pablo Street, Suite 514, Los Angeles, CA, 90033, USA
| | - Namir Katkhouda
- Department of General Surgery, Keck Medical Center, University of Southern California, 1510 San Pablo Street, Suite 514, Los Angeles, CA, 90033, USA.
| |
Collapse
|
73
|
Regan J, Walshe M, Timon C, McMahon BP. 'Endoflip® evaluation of pharyngo-oesophageal segment tone and swallowing in a clinical population: a total laryngectomy case series'. Clin Otolaryngol 2016; 40:121-9. [PMID: 25314664 DOI: 10.1111/coa.12337] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/05/2014] [Indexed: 11/29/2022]
Abstract
OBJECTIVES To evaluate safety of positioning and distending the functional lumen imaging probe in the pharyngo-oesophageal segment in adults with known pharyngo-oesophageal segment dysfunction and to obtain preliminary measurements of pharyngo-oesophageal segment distensibility and opening during swallowing in a clinical group. METHODS Prospective case series of ten adults post total laryngectomy (61-75 years) recruited from an outpatient ENT clinic. Functional lumen imaging probe was inserted trans-nasally, and the balloon was positioned in the pharyngo-oesophageal segment. Two 20-mL ramp distensions were completed, and subjects performed two dry and two 5-mL and 10-mL liquid swallows at a 12-mL balloon volume. Pharyngo-oesophageal segment distensibility was calculated from cross-sectional area (mm(2) ) and intraballoon pressure (mmHg) measures. During swallowing, extent (mm) and duration (secs) of pharyngo-oesophageal segment opening and intraballoon pressure drop (mmHg) were evaluated. RESULTS Functional lumen imaging probe could be passed through the pharyngo-oesophageal segment in seven subjects, all of whom completed the protocol. During distensions, pharyngo-oesophageal segment cross-sectional area increased significantly (19.47-148.3 mm(2) , P < 0.001), and intraballoon pressure increased significantly (15- to 20-mL balloon volume, P = 0.005). Pharyngo-oesophageal segment diameter (5.1 mm) increased during dry (7.4 mm), 5-mL (7.3 mm) and 10-mL (7.7 mm) liquid swallows (P = 0.018). Pharyngo-oesophageal segment opening duration varied across dry (1 s), 5-mL (0.8 s) and 10-mL (1.6 s) liquid swallows. Resting intraballoon pressure (25.5 mmHg) did not alter significantly during swallowing (P = 0.656). CONCLUSION Functional lumen imaging probe provides novel quantitative information regarding pharyngo-oesophageal segment distensibility and opening during swallowing in adults post total laryngectomy. No adverse events were observed in this first clinical study. Data were easy to acquire, and measures may direct candidacy for and establish effectiveness of interventions to alter pharyngo-oesophageal segment tone.
Collapse
Affiliation(s)
- J Regan
- Department of Speech & Language Therapy, Adelaide and Meath Hospital, Dublin, Ireland
| | | | | | | |
Collapse
|
74
|
Kessing BF, Bredenoord AJ, Schijven MP, van der Peet DL, van Berge Henegouwen MI, Smout AJPM. Long-term effects of anti-reflux surgery on the physiology of the esophagogastric junction. Surg Endosc 2015; 29:3726-32. [PMID: 25786903 PMCID: PMC4648952 DOI: 10.1007/s00464-015-4144-7] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2014] [Accepted: 12/04/2014] [Indexed: 12/29/2022]
Abstract
BACKGROUND Studies performed shortly after anti-reflux surgery have demonstrated that the reduction of reflux episodes is caused by a decrease in the rate of transient lower esophageal sphincter relaxations (TLESRs) and a decrease in the distensibility of the esophagogastric junction (EGJ). We aimed to assess the long-term effects of surgical fundoplication on the physiology of the EGJ. METHODS We included 18 patients who underwent surgical fundoplication >5 years before and 10 GERD patients who did not have surgery. Patients underwent 90-min combined high-resolution manometry and pH-impedance monitoring, and EGJ distensibility was assessed. RESULTS Post-fundoplication patients exhibited a lower frequency of reflux events than GERD patients (2.0 ± 0.5 vs 15.1 ± 4.3, p < 0.05). The rate of TLESRs (6.1 ± 0.9 vs 12.6 ± 1.0, p < 0.05) and their association with reflux (28.3 ± 9.0 vs 74.9 ± 6.9 %, p < 0.05) was lower in post-fundoplication patients than in GERD patients. EGJ distensibility was significantly lower in post-fundoplication patients than in GERD patients. Recurrence of GERD symptoms after fundoplication was not associated with an increased number of reflux episodes, nor was it associated with an increased distensibility of the EGJ or an increase in the number of TLESRs. CONCLUSION More than 5 years after anti-reflux surgery, patients still exhibit a lower rate of TLESRs and a reduced distensibility of the EGJ compared with medically treated GERD patients. These data suggest that the effects of surgical fundoplication on EGJ physiology persist at the long term and underlie the persistent reduction of reflux events.
Collapse
Affiliation(s)
- Boudewijn F Kessing
- Department of Gastroenterology and Hepatology, Academic Medical Center, Meibergdreef 9, 1105 AZ, Amsterdam, The Netherlands.
| | - Albert J Bredenoord
- Department of Gastroenterology and Hepatology, Academic Medical Center, Meibergdreef 9, 1105 AZ, Amsterdam, The Netherlands
| | | | | | | | - André J P M Smout
- Department of Gastroenterology and Hepatology, Academic Medical Center, Meibergdreef 9, 1105 AZ, Amsterdam, The Netherlands
| |
Collapse
|
75
|
Lottrup C, Gregersen H, Liao D, Fynne L, Frøkjær JB, Krogh K, Regan J, Kunwald P, McMahon BP. Functional lumen imaging of the gastrointestinal tract. J Gastroenterol 2015; 50:1005-16. [PMID: 25980822 DOI: 10.1007/s00535-015-1087-7] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/16/2015] [Accepted: 04/28/2015] [Indexed: 02/04/2023]
Abstract
This nonsystematic review aims to describe recent developments in the use of functional lumen imaging in the gastrointestinal tract stimulated by the introduction of the functional lumen imaging probe. When ingested food in liquid and solid form is transported along the gastrointestinal tract, sphincters provide an important role in the flow and control of these contents. Inadequate function of sphincters is the basis of many gastrointestinal diseases. Despite this, traditional methods of sphincter diagnosis and measurement such as fluoroscopy, manometry, and the barostat are limited in what they can tell us. It has long been thought that measurement of sphincter function through resistance to distension is a better approach, now more commonly known as distensibility testing. The functional lumen imaging probe is the first medical measurement device that purports in a practical way to provide geometric profiling and measurement of distensibility in sphincters. With use of impedance planimetry, an axial series of cross-sectional areas and pressure in a catheter-mounted allantoid bag are used for the calculation of distensibility parameters. The technique has been trialed in many valvular areas of the gastrointestinal tract, including the upper esophageal sphincter, the esophagogastric junction, and the anorectal region. It has shown potential in the biomechanical assessment of sphincter function and characterization of swallowing disorders, gastroesophageal reflux disease, eosinophilic esophagitis, achalasia, and fecal incontinence. From this early work, the functional lumen imaging technique has the potential to contribute to a better and more physiological understanding of narrowing regions in the gastrointestinal tract in general and sphincters in particular.
Collapse
Affiliation(s)
- Christian Lottrup
- Mech-Sense, Department of Gastroenterology and Hepatology, Aalborg University Hospital, Aalborg, Denmark.
| | - Hans Gregersen
- GIOME and the Key Laboratory for Biorheological Science and Technology of Ministry of Education, Bioengineering College of Chongqing University, 83 Shabei Lu, 400044, Chongqing, China.
| | - Donghua Liao
- GIOME Academia, Department of Medicine, Aarhus University, Aarhus, Denmark
| | - Lotte Fynne
- Neurogastroenterology Unit, Department of Hepatology and Gastroenterology, Aarhus University Hospital, Aarhus, Denmark
| | - Jens Brøndum Frøkjær
- Mech-Sense, Department of Radiology, Aalborg University Hospital, Aalborg, Denmark.,Department of Clinical Medicine, Aalborg University, Aalborg, Denmark
| | - Klaus Krogh
- Neurogastroenterology Unit, Department of Hepatology and Gastroenterology, Aarhus University Hospital, Aarhus, Denmark
| | - Julie Regan
- Trinity Academic Gastroenterology Group, Tallaght Hospital, Dublin, Ireland
| | - Peter Kunwald
- Mech-Sense, Department of Gastroenterology and Hepatology, Aalborg University Hospital, Aalborg, Denmark
| | - Barry P McMahon
- GIOME and the Key Laboratory for Biorheological Science and Technology of Ministry of Education, Bioengineering College of Chongqing University, 83 Shabei Lu, 400044, Chongqing, China.,Trinity Academic Gastroenterology Group, Tallaght Hospital, Dublin, Ireland
| |
Collapse
|
76
|
Advances in the evaluation and management of esophageal disease of systemic sclerosis. Curr Rheumatol Rep 2015; 17:475. [PMID: 25475597 DOI: 10.1007/s11926-014-0475-y] [Citation(s) in RCA: 32] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
Symptoms of heartburn and dysphagia as well as objective findings of abnormal esophageal acid exposure and esophageal dysmotility are common in patients with systemic sclerosis (SSc). Treatments for SSc esophageal disease are generally limited to gastroesophageal reflux disease (GERD) treatment with proton pump inhibitors. Progresses made in esophageal diagnostic testing offer the potential for improved clinical characterization of esophageal disease in SSc that may help direct management decisions. In addition to reviewing GERD management in patients with SSc, present and potential uses of endoscopy, reflux monitoring, manometry, impedance planimetry, and endoscopic ultrasound are discussed.
Collapse
|
77
|
Abstract
The diagnosis of esophageal motility disorders has been greatly enhanced with the development of high-resolution esophageal manometry studies and the Chicago Classification. Both hypomotility disorders and hypercontractility disorders of the esophagus have new diagnostic criteria. For the foregut surgeon, new diagnostic criteria for esophageal motility disorders have implications for decision-making during fundoplication and may expand the role of surgical therapy for esophageal achalasia by clarifying diagnostic criteria.
Collapse
Affiliation(s)
- Steven P Bowers
- Mayo Clinic Florida, Department of Surgery, 4500 San Pablo Road, Jacksonville, FL 32224, USA.
| |
Collapse
|
78
|
Identification of biomechanical properties in vivo in human uterine cervix. J Mech Behav Biomed Mater 2014; 39:27-37. [PMID: 25084120 DOI: 10.1016/j.jmbbm.2014.07.005] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2014] [Revised: 06/30/2014] [Accepted: 07/04/2014] [Indexed: 11/22/2022]
Abstract
BACKGROUND AND AIMS The course and outcome of pregnancy is closely correlated to change of biomechanical properties of the uterine cervix. The aim of this study was to build a non-linear, fiber reinforced mechanical model of the cervix for estimation of mechanical characteristics of the cervix in early- and term-pregnant women based on recordings of in vivo pressure and diameter by means of the Functional Luminal Imaging Probe (FLIP) technology. MATERIALS AND METHODS Five early- and six term-pregnant women were examined with a FLIP probe. The bag on the probe was inserted into the cervical canal for concomitant measurement of diameters at 16 serial locations along the canal and the bag pressure. The bag was inflated to a maximum volume of 50 ml. A three-fiber-families model including isotropic elastin-dominated matrix and anisotropic collagen was introduced to describe the mechanical behavior of the cervical canal. The unknown geometric and mechanical parameters were calculated on the basis of the mid-cervical diameters and the intraluminal pressures during the inflation. RESULTS The wall thickness in the unloaded state (zero pressure applied) and mechanical properties of the matrix material (c) and collagens (c1, c2) were estimated with good fits of the calculated intraluminal pressures to the FLIP recordings during the cervical canal distension. No significant difference in the wall thickness was found between the early- and term-pregnant women (10.3 ± 0.8mm vs. 11.7 ± 2.2mm, p=0.30). The cervical matrix material and the collagen in the early-pregnant women were much stiffer than that in the term-pregnant women (p<0.05). CONCLUSIONS The cervical mechanical properties can be obtained from recorded pressure and diameter data in vivo via the established mechanical model. Matrix material and collagens of the cervix wall were remodeled during pregnancy. The mechanical model can be applied to other tubular visceral organs where concomitant measures of pressure and diameter can be obtained for better understanding diseases and their evolution or treatment.
Collapse
|
79
|
Perretta S, McAnena O, Botha A, Nathanson L, Swanstrom L, Soper NJ, Inoue H, Ponsky J, Jobe B, Marescaux J, Dallemagne B. Acta from the EndoFLIP® Symposium. Surg Innov 2013; 20:545-52. [PMID: 24379172 DOI: 10.1177/1553350613513515] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Laparoscopic fundoplication (LF) is a surgical treatment for gastroesophageal reflux disease (GERD) that has been performed for more than 20 years. High-volume centers of excellence report long-term success rates greater than 90% with LF. On the other hand, general population-based outcomes are reported to be markedly worse, leading to a nihilistic perception of the procedure on the part of the medical referral population. The lack of standardization of the technique and the lack of tools to calibrate objectively the repairs are probably among the causes of variability in the outcomes and may explain the decline in the number of LF procedures in recent years. The functional lumen imaging probe (EndoFLIP(®)) device is essentially a "smart bougie" in the form of a balloon catheter that measures shape and compliance of the gastroesophageal junction (GEJ) during surgery using impedance planimetry. With approximately 3 years of international experience gained with this tool, a symposium was convened in October 2012 in Strasbourg, France, with the aim of determining if intraoperative EndoFLIP use could provide standardization of surgical treatment of GERD through the understanding of physiological changes occurring to the GEJ during fundoplication. This article provides a brief history of the EndoFLIP system and reviews data previously published on the use of EndoFLIP to characterize the GEJ in normal subjects. It then summarizes the data from the 5 high-volume international sites with expert surgeons performing LF presented in Strasbourg to objectively profile the characteristics of a normal postoperative GEJ.
Collapse
Affiliation(s)
- Silvana Perretta
- 1IRCAD, Department of Digestive and Endocrine Surgery, University of Strasbourg, Strasbourg, France
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
80
|
Effect of transoral incisionless fundoplication on reflux mechanisms. Surg Endosc 2013; 28:941-9. [PMID: 24149854 DOI: 10.1007/s00464-013-3250-7] [Citation(s) in RCA: 40] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2013] [Accepted: 09/30/2013] [Indexed: 12/21/2022]
Abstract
OBJECTIVES Transoral incisionless fundoplication (TIF) is a new endoscopic treatment option for gastroesophageal reflux disease (GERD). The mechanisms underlying the anti-reflux effect of this new procedure have not been studied. We therefore conducted this explorative study to evaluate the effect of TIF on reflux mechanisms, focusing on transient lower esophageal sphincter relaxations (TLESRs) and esophagogastric junction (EGJ) distensibility. METHODS GERD patients (N = 15; 11 males, mean age 41 years, range 23-66), dissatisfied with medical treatment were studied before and 6 months after TIF. We performed 90-min postprandial combined high-resolution manometry and impedance-pH monitoring and an ambulatory 24-h pH-impedance monitoring. EGJ distensibility was evaluated using an endoscopic functional luminal imaging probe before and directly after the procedure. RESULTS TIF reduced the number of postprandial TLESRs (16.8 ± 1.5 vs. 9.2 ± 1.3; p < 0.01) and the number of postprandial TLESRs associated with reflux (11.1 ± 1.6 vs. 5.6 ± 0.6; p < 0.01), but the proportion of TLESRs associated with reflux was unaltered (67.6 ± 6.9 vs. 69.9 ± 6.3 %). TIF also led to a decrease in the number and proximal extent of reflux episodes and an improvement of acid exposure in the upright position; conversely, TIF had no effect on the number of gas reflux episodes. EGJ distensibility was reduced after the procedure (2.4 ± 0.3 vs. 1.6 ± 0.2 mm(2)/mmHg; p < 0.05). CONCLUSIONS TIF reduced the number of postprandial TLESRs, the number of TLESRs associated with reflux and EGJ distensibility. This resulted in a reduction of the number and proximal extent of reflux episodes and improvement of acid exposure in the upright position. The anti-reflux effect of TIF showed to be selective for liquid-containing reflux only, thereby preserving the ability of venting gastric air.
Collapse
|
81
|
Neumann H, Neurath MF, Vieth M, Lever FM, Meijer GJ, Lips IM, McMahon BP, Ruurda J, van Hillegersberg R, Siersema P, Levine MS, Scharitzer M, Pokieser P, Zerbib F, Savarino V, Zentilin P, Savarino E, Chan WW. Innovative techniques in evaluating the esophagus; imaging of esophageal morphology and function; and drugs for esophageal disease. Ann N Y Acad Sci 2013; 1300:11-28. [DOI: 10.1111/nyas.12233] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Affiliation(s)
- Helmut Neumann
- Department of Medicine I; University of Erlangen; Erlangen Germany
| | | | - Michael Vieth
- Institute of Pathology; Klinikum Bayreuth; Bayreuth Germany
| | | | - Gert J. Meijer
- Department of Radiation Oncology; UMC Utrecht; Utrecht the Netherlands
| | - Irene M. Lips
- Department of Radiation Oncology; UMC Utrecht; Utrecht the Netherlands
| | - Barry P. McMahon
- Trinity Academic Gastroenterology Group; Tallaght Hospital; Dublin Ireland
| | - J.P. Ruurda
- Departments of Surgery and Gastroenterolgy; University Medical Center Utrecht; Utrecht the Netherlands
| | - R. van Hillegersberg
- Departments of Surgery and Gastroenterolgy; University Medical Center Utrecht; Utrecht the Netherlands
| | - P. Siersema
- Departments of Surgery and Gastroenterolgy; University Medical Center Utrecht; Utrecht the Netherlands
| | - Marc S. Levine
- Department of Gastrointestinal Radiology; University of Pennsylvania Medical Center; Philadelphia Pennsylvania
- Department of Radiology; Perelman School of Medicine at the University of Pennsylvania; Philadelphia Pennsylvania
| | | | - Peter Pokieser
- Department of Radiology; Medical University of Vienna; Vienna Austria
| | - Frank Zerbib
- Department of Gastroenterology; CHU Bordeaux, Saint Andre Hospital; Bordeaux France
| | | | | | - Edoardo Savarino
- Department of Surgical; Oncological and Gastroenterological Sciences; University of Padua; Padua Italy
| | - Walter W. Chan
- Division of Gastroenterology, Hepatology and Endoscopy; Brigham and Women's Hospital; Harvard Medical School; Boston Massachusetts
| |
Collapse
|
82
|
Lenglinger J, See SF, Beller L, Cosentini EP, Asari R, Wrba F, Riegler M, Schoppmann SF. Review on novel concepts of columnar lined esophagus. Wien Klin Wochenschr 2013; 125:577-90. [PMID: 24061694 DOI: 10.1007/s00508-013-0418-z] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2012] [Accepted: 07/28/2013] [Indexed: 12/20/2022]
Abstract
BACKGROUND Columnar lined esophagus (CLE) is a marker for gastroesophageal reflux and associates with an increased cancer risk among those with Barrett's esophagus. Recent studies fostered the development of integrated CLE concepts. METHODS Using PubMed, we conducted a review of studies on novel histopathological concepts of nondysplastic CLE. RESULTS Two histopathological concepts-the squamo-oxyntic gap (SOG) and the dilated distal esophagus (DDE), currently model our novel understanding of CLE. As a consequence of reflux, SOG interposes between the squamous lined esophagus and the oxyntic mucosa of the proximal stomach. Thus the SOG describes the histopathology of CLE within the tubular esophagus and the DDE, which is known to develop at the cost of a shortened lower esophageal sphincter and foster increased acid gastric reflux. Histopathological studies of the lower end of the esophagus indicate, that the DDE is reflux damaged, dilated, gastric type folds forming esophagus and cannot be differentiated from proximal stomach by endoscopy. While the endoscopically visible squamocolumnar junction (SCJ) defines the proximal limit of the SOG, the assessment of the distal limit requires the histopathology of measured multilevel biopsies. Within the SOG, CLE types distribute along a distinct zonation with intestinal metaplasia (IM; Barrett's esophagus) and/or cardiac mucosa (CM) at the SCJ and oxyntocardiac mucosa (OCM) within the distal portion of the SOG. The zonation follows the pH-gradient across the distal esophagus. Diagnosis of SOG and DDE includes endoscopy, histopathology of measured multi-level biopsies from the distal esophagus, function, and radiologic tests. CM and OCM do not require treatment and are surveilled in 5 year intervals, unless they associate with life quality impairing symptoms, which demand medical or surgical therapy. In the presence of an increased cancer risk profile, it is justified to consider radiofrequency ablation (RFA) of IM within clinical studies in order to prevent the progression to dysplasia and cancer. Dysplasia justifies RFA ± endoscopic resection. CONCLUSIONS SOG and DDE represent novel concepts fusing the morphological and functional aspects of CLE. Future studies should examine the impact of SOG and DDE for monitoring and management of gastroesophageal reflux disease (GERD).
Collapse
Affiliation(s)
- Johannes Lenglinger
- Manometry Lab & Upper GI Service, Department of Surgery, University Clinic of Surgery, CCC-GET, Medical University of Vienna, Vienna General Hospital, Währinger Gürtel 18-20, 1090, Vienna, Austria
| | | | | | | | | | | | | | | |
Collapse
|
83
|
Esophageal distensibility as a measure of disease severity in patients with eosinophilic esophagitis. Clin Gastroenterol Hepatol 2013; 11:1101-1107.e1. [PMID: 23591279 PMCID: PMC3790569 DOI: 10.1016/j.cgh.2013.03.020] [Citation(s) in RCA: 213] [Impact Index Per Article: 19.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/06/2012] [Revised: 02/20/2013] [Accepted: 03/01/2013] [Indexed: 02/06/2023]
Abstract
BACKGROUND & AIMS The aim of this study was to assess whether measurements of esophageal distensibility, made by high-resolution impedance planimetry, correlated with important clinical outcomes in patients with eosinophilic esophagitis. METHODS Seventy patients with eosinophilic esophagitis (50 men; age, 18-68 y) underwent endoscopy with esophageal biopsy collection and high-resolution impedance planimetry using the functional lumen-imaging probe. The patients were followed up prospectively for an average of 9.2 months (range, 3-14 mo), and the risk of food impaction, requirement for dilation, and symptom severity during the follow-up period was determined from medical records. Esophageal distensibility metrics and the severity of mucosal eosinophilia at baseline were compared between patients presenting with and without food impaction and those requiring or not requiring esophageal dilation. Logistic regression and stratification assessments were used to assess the predictive value of esophageal distensibility metrics in assessing risk of food impaction, the need for dilation, and continued symptoms. RESULTS Patients with prior food impactions had significantly lower distensibility plateau (DP) values than those with solid food dysphagia alone. In addition, patients sustaining food impaction and requiring esophageal dilation during the follow-up period had significantly lower DP values than those who did not. The severity of mucosal eosinophilia did not correlate with risk for food impaction, the requirement for dilation during follow-up evaluation, or DP values. CONCLUSIONS Reduced esophageal distensibility predicts risk for food impaction and the requirement for esophageal dilation in patients with eosinophilic esophagitis. The severity of mucosal eosinophilia was not predictive of these outcomes and had a poor correlation with esophageal distensibility.
Collapse
|
84
|
Ilczyszyn A, Botha AJ. Feasibility of esophagogastric junction distensibility measurement during Nissen fundoplication. Dis Esophagus 2013; 27:637-44. [PMID: 24033477 DOI: 10.1111/dote.12130] [Citation(s) in RCA: 56] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Increased esophagogastric junction distensibility has been implicated in the development of gastroesophageal reflux disease (GERD). Previous authors have demonstrated a reduction in distensibility following anti-reflux surgery, but the changes during the operation are not clear. Our study aimed to ascertain the feasibility of measuring intraoperative distensibility changes and to assess if this would have potential to modify the operation. Seventeen patients with GERD were managed in a standardized manner consisting of preoperative assessment with symptom scoring, endoscopy, 24 hours pH studies, and manometry. Patients then underwent laparoscopic Nissen fundoplication with intraoperative distensibility measurement using an EndoFLIP EF-325 functional luminal imaging probe (Crospon Ltd, Galway, Ireland). This device utilizes impedance planimetry technology to measure cross-sectional area and distensibility within a balloon-tipped catheter. This is inflated at the esophagogastric junction to fixed distension volumes. Thirty-second median cross-sectional area and intraballoon pressure measurements were recorded at 30 and 40 mL balloon distensions. Measurement time points were initially after induction of anesthesia, after pneumoperitoneum, after hiatal mobilization, after hiatal repair, after fundoplication, and finally pre-extubation. Postoperatively, patients continued on protocol and were discharged after a two-night stay tolerating a sloppy diet. Patients with a hiatus hernia on high-resolution manometry had a significantly higher initial esophagogastric junction distensibility index (DI) than those without. Hiatus repair and fundoplication resulted in a significant overall reduction in the median DI from the initial to final recordings (30 mL balloon distension reduction of 3.26 mm(2) /mmHg (P = 0.0087), 40 mL balloon distension reduction of 2.39 mm(2) /mmHg [P = 0.0039]). There was also a significant reduction in the DI after pneumoperitoneum, hiatus repair, and fundoplication at 40 mL balloon distension. Two individual cases in the series highlight the utility of the system in potentially changing the operation. After fundoplication, patient 7 recorded a DI of 0.47 mm(2) /mmHg, the lowest in our series, and subsequently required reoperation because of significant symptoms of dysphagia. Patient 12 had a fundoplication that appeared visually too tight and was converted intraoperatively to a Lind 270° wrap resulting in a change in the DI from 0.65 to 0.89 mm(2) /mmHg. Laparoscopic Nissen fundoplication results in a significant reduction in the distensibility of the esophagogastric junction. The EndoFLIP system is able to demonstrate significant changes during the operation and may help guide intraoperative modification. Larger multicenter studies with long-term follow up would be beneficial to develop a target range of distensibility associated with good outcome.
Collapse
Affiliation(s)
- A Ilczyszyn
- Department of Upper GI Surgery, Guys' and St Thomas' NHS Foundation Trust, St Thomas' Hospital, London, UK
| | | |
Collapse
|
85
|
Pandolfino JE, de Ruigh A, Nicodème F, Xiao Y, Boris L, Kahrilas PJ. Distensibility of the esophagogastric junction assessed with the functional lumen imaging probe (FLIP™) in achalasia patients. Neurogastroenterol Motil 2013; 25:496-501. [PMID: 23413801 PMCID: PMC3789137 DOI: 10.1111/nmo.12097] [Citation(s) in RCA: 157] [Impact Index Per Article: 14.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/14/2012] [Accepted: 01/11/2013] [Indexed: 12/17/2022]
Abstract
BACKGROUND The functional lumen imaging probe (FLIP), measures esophagogastric junction (EGJ) distensibility (cross-sectional area/luminal pressure) during volume-controlled distension. The aim of this study is to apply this tool to the assessment of the EGJ in untreated and treated achalasia patients and to compare EGJ distensibility with other diagnostic tools utilized in managing achalasia. METHODS Findings from FLIP, high-resolution manometry (HRM), timed barium esophagram, and symptom assessment by Eckardt Score (ES) were compared in 54 achalasia patients (23 untreated, 31 treated). Twenty healthy volunteers underwent FLIP as a comparator group. The EGJ distensibility index (EGJ-DI) was defined at the 'waist' of the FLIP bag during volumetric distension, expressed in mm(2) mmHg(-1) . The ES was used to gauge treatment outcome: good response < 3 or poor response ≥ 3. KEY RESULTS Of the 31 treated patients, 17 had good and 14 poor treatment response. The EGJ-DI was significantly different among groups, greatest in the control subjects and least in the untreated patients; patients with good treatment response had significantly greater EGJ-DI than untreated or patients with poor response. The correlations between EGJ-DI and ES and integrated relaxation pressure on HRM were significant. CONCLUSIONS & INFERENCES The FLIP provided a useful measure of EGJ distensibility in achalasia patients that correlated with symptom severity. The measurement of EGJ distensibility was complementary to existing tests suggesting a potentially important role in the clinical management of achalasia.
Collapse
Affiliation(s)
- J. E. Pandolfino
- Department of Medicine; Feinberg School of Medicine; Northwestern University; Chicago; IL; USA
| | - A. de Ruigh
- Department of Medicine; Feinberg School of Medicine; Northwestern University; Chicago; IL; USA
| | - F. Nicodème
- Department of Medicine; Feinberg School of Medicine; Northwestern University; Chicago; IL; USA
| | - Y. Xiao
- Department of Medicine; Feinberg School of Medicine; Northwestern University; Chicago; IL; USA
| | - L. Boris
- Department of Medicine; Feinberg School of Medicine; Northwestern University; Chicago; IL; USA
| | - P. J. Kahrilas
- Department of Medicine; Feinberg School of Medicine; Northwestern University; Chicago; IL; USA
| |
Collapse
|
86
|
Gyawali CP, Bredenoord AJ, Conklin JL, Fox M, Pandolfino JE, Peters JH, Roman S, Staiano A, Vaezi MF. Evaluation of esophageal motor function in clinical practice. Neurogastroenterol Motil 2013; 25:99-133. [PMID: 23336590 DOI: 10.1111/nmo.12071] [Citation(s) in RCA: 87] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Esophageal motor function is highly coordinated between central and enteric nervous systems and the esophageal musculature, which consists of proximal skeletal and distal smooth muscle in three functional regions, the upper and lower esophageal sphincters, and the esophageal body. While upper endoscopy is useful in evaluating for structural disorders of the esophagus, barium esophagography, radionuclide transit studies, and esophageal intraluminal impedance evaluate esophageal transit and partially assess motor function. However, esophageal manometry is the test of choice for the evaluation of esophageal motor function. In recent years, high-resolution manometry (HRM) has streamlined the process of acquisition and display of esophageal pressure data, while uncovering hitherto unrecognized esophageal physiologic mechanisms and pathophysiologic patterns. New algorithms have been devised for analysis and reporting of esophageal pressure topography from HRM. The clinical value of HRM extends to the pediatric population, and complements preoperative evaluation prior to foregut surgery. Provocative maneuvers during HRM may add to the assessment of esophageal motor function. The addition of impedance to HRM provides bolus transit data, but impact on clinical management remains unclear. Emerging techniques such as 3-D HRM and impedance planimetry show promise in the assessment of esophageal sphincter function and esophageal biomechanics.
Collapse
Affiliation(s)
- C P Gyawali
- Division of Gastroenterology, Washington University School of Medicine, St. Louis, MO, USA.
| | | | | | | | | | | | | | | | | |
Collapse
|
87
|
Alqudah MM, Gregersen H, Drewes AM, McMahon BP. Evaluation of anal sphincter resistance and distensibility in healthy controls using EndoFLIP ©. Neurogastroenterol Motil 2012; 24:e591-9. [PMID: 23072480 DOI: 10.1111/nmo.12028] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
BACKGROUND Ano-rectal disorders are common in the general population. Although they are not life threatening conditions, they do represent a social stigma and a reduced quality of life for the sufferer. The underlying physiology of muscle function contributing to ano-rectal competence is complex and there is room for a much better understanding so that treatments can improve. METHODS A cylindrically shaped, liquid filled bag (12 cm long), mounted on a catheter was inserted into the anus and positioned straddling the ano-rectal region in 20 healthy volunteers (10 females). Series of volume-controlled distensions (40 mL min(-1) to 40 mL) were carried out and data on 16 CSA at 5 mm apart and bag pressure were recorded. Provocative tests using squeeze and cough at bag volumes of 20, 30, and 40 mL were carried out. KEY RESULTS Ramp distension of the anal canal showed that the opening pressure for females (mean, 11 mmHg) was higher than for males (mean, 5 mmHg) (P < 0.001). Geometric profile of the anal canal at low distension volumes showed narrow bands at proximal and distal ends of the anal profile and shortening of a middle narrow zone at higher volumes. Inter-individual differences were observed in the behavior of the proximal end and the distal end of the anal profile during squeeze. CONCLUSIONS & INFERENCES This distensibility technique provides an important new way of studying the anal canal and hence may have a role in testing sphincter competence in patients with disorders.
Collapse
Affiliation(s)
- M M Alqudah
- Department of Clinical Medicine, Trinity College, University of Dublin, Dublin, Ireland
| | | | | | | |
Collapse
|
88
|
Intraoperative assessment of esophagogastric junction distensibility during per oral endoscopic myotomy (POEM) for esophageal motility disorders. Surg Endosc 2012. [PMID: 22955896 DOI: 10.1007/s00464-012-2484-0.] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/29/2022]
Abstract
BACKGROUND Per oral endoscopic myotomy (POEM) is a novel treatment for esophageal motility disorders such as achalasia. To date, the extent of the myotomy has been determined based on the subjective assessment of the endoscopist. We hypothesized that the real-time measurement of esophagogastric junction (EGJ) distensibility using a novel functional lumen-imaging probe would enable objective evaluation of POEM. METHODS Patients diagnosed with achalasia disorders electively underwent POEM. Using impedance planimetry with a transorally inserted functional lumen-imaging probe (EndoFLIP), cross-sectional areas (CSA) and distensibilities at the EGJ were measured intraoperatively immediately before and after the transoral myotomy (n = 4). All patients completed their 6-month follow-up and two patients had repeat distensibility tests at this time. Four healthy volunteers served as a control group. RESULTS POEM was successfully performed in all patients (4/4). Premyotomy measurements (40-ml fill mode) showed a median diameter of 6.5 mm (range = 5.2-7.9 mm) at the narrowest location of the EGJ and was 10.1 mm (7.3-13.2 mm) following POEM. CSA increased from 41.5 mm(2) (20-49 mm(2)) to 86 mm(2) (41-137 mm(2)) at a similar median intraballoon pressure (40.3 vs. 38.6 mmHg). The increased EGJ distensibility (DI, 1.0 vs. 2.4 mm(2)/mmHg) was comparable to that of healthy volunteers (2.7 mm(2)/mmHg). CONCLUSION Functional lumen distensibility measures show that POEM can result in an immediate correction of the nonrelaxing lower esophageal sphincter, which appears similar to that of healthy controls. Intraoperative EGJ profiling may be an important tool to objectively guide the needed extent and completeness of the myotomy during POEM.
Collapse
|
89
|
Rieder E, Swanström LL, Perretta S, Lenglinger J, Riegler M, Dunst CM. Intraoperative assessment of esophagogastric junction distensibility during per oral endoscopic myotomy (POEM) for esophageal motility disorders. Surg Endosc 2012; 27:400-5. [PMID: 22955896 DOI: 10.1007/s00464-012-2484-0] [Citation(s) in RCA: 88] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2012] [Accepted: 06/19/2012] [Indexed: 12/14/2022]
Abstract
BACKGROUND Per oral endoscopic myotomy (POEM) is a novel treatment for esophageal motility disorders such as achalasia. To date, the extent of the myotomy has been determined based on the subjective assessment of the endoscopist. We hypothesized that the real-time measurement of esophagogastric junction (EGJ) distensibility using a novel functional lumen-imaging probe would enable objective evaluation of POEM. METHODS Patients diagnosed with achalasia disorders electively underwent POEM. Using impedance planimetry with a transorally inserted functional lumen-imaging probe (EndoFLIP), cross-sectional areas (CSA) and distensibilities at the EGJ were measured intraoperatively immediately before and after the transoral myotomy (n = 4). All patients completed their 6-month follow-up and two patients had repeat distensibility tests at this time. Four healthy volunteers served as a control group. RESULTS POEM was successfully performed in all patients (4/4). Premyotomy measurements (40-ml fill mode) showed a median diameter of 6.5 mm (range = 5.2-7.9 mm) at the narrowest location of the EGJ and was 10.1 mm (7.3-13.2 mm) following POEM. CSA increased from 41.5 mm(2) (20-49 mm(2)) to 86 mm(2) (41-137 mm(2)) at a similar median intraballoon pressure (40.3 vs. 38.6 mmHg). The increased EGJ distensibility (DI, 1.0 vs. 2.4 mm(2)/mmHg) was comparable to that of healthy volunteers (2.7 mm(2)/mmHg). CONCLUSION Functional lumen distensibility measures show that POEM can result in an immediate correction of the nonrelaxing lower esophageal sphincter, which appears similar to that of healthy controls. Intraoperative EGJ profiling may be an important tool to objectively guide the needed extent and completeness of the myotomy during POEM.
Collapse
Affiliation(s)
- Erwin Rieder
- Gastrointestinal and Minimally Invasive Surgery, The Oregon Clinic, Portland, OR, USA.
| | | | | | | | | | | |
Collapse
|
90
|
Abstract
The purpose of this review is to consider the neuromuscular mechanism of LES contractility both by itself and in relation to the esophagogastric junction (EGJ) complex in order to appreciate the intricacies of EGJ valvular function.
Collapse
Affiliation(s)
- M A Kwiatek
- Department of Medicine, Northwestern University, Feinberg School of Medicine, Chicago, IL, USA.
| | | |
Collapse
|
91
|
Regan J, Walshe M, Rommel N, McMahon BP. A new evaluation of the upper esophageal sphincter using the functional lumen imaging probe: a preliminary report. Dis Esophagus 2012; 26:117-23. [PMID: 22394295 DOI: 10.1111/j.1442-2050.2012.01331.x] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Objective and reliable evaluation of upper esophageal sphincter (UES) opening during swallowing based on videofluoroscopy and pharyngeal manometry challenges dysphagia clinicians. The functional lumen imaging probe (FLIP) is a portable tool based on impedance planimetry originally designed to measure esophogastric junction compliance. It is hypothesized that FLIP can evaluate UES distensibility, and can provide UES diameter and pressure measurements at rest, during swallowing, and during voluntary maneuvers. Eleven healthy adult subjects consented to FLIP evaluation. The probe was inserted transorally, and the balloon was positioned across the UES. Two 20-mL ramp distensions were completed. Changes in UES diameter and intraballoon pressure were measured during dry and 5-mL liquid swallows, and during voluntary swallow postures and maneuvers employed in clinical practice. The protocol was completed by 10 of 11 healthy subjects. Mean intraballoon pressure increased throughout 5-mL (5.8 mmHg; -4.5-18.6 mmHg), 10-mL (8.7 mmHg; 2.3-28.5 mmHg), 15-mL (17.3 mmHg; 9.5-34.8 mmHg), and 20-mL (31.2 mmHg; 16-46.3 mmHg) balloon volumes. Mean resting UES diameter (4.9 mm) increased during dry swallows (9.2 mm) and 5-mL liquid swallows (7.7 mm). Mean UES diameter increased during 5-mL liquid swallows with head turn to right (8.1 mm) and left (8.3 mm), chin tuck (8.4 mm), effortful swallow (8.5 mm), Mendelsohn maneuver (8.1 mm), and supraglottic swallow (7.8 mm). FLIP was safely inserted and distended in the UES, and provided useful quantitative data regarding UES distensibility and UES diameter changes during swallowing maneuvers. Further research is being conducted to explore the role of FLIP in UES evaluation.
Collapse
Affiliation(s)
- J Regan
- School of Clinical Medicine, Trinity College Dublin, Ireland.
| | | | | | | |
Collapse
|
92
|
Fox M, Sweis R. Future directions in esophageal motility and function - new technology and methodology. Neurogastroenterol Motil 2012; 24 Suppl 1:48-56. [PMID: 22248108 DOI: 10.1111/j.1365-2982.2011.01835.x] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
BACKGROUND Symptom based diagnosis is not reliable in patients with swallowing problems, heartburn, and other dyspeptic complaints. The aim of investigation is to provide clinically relevant measurements of gastrointestinal structure and function that explain the cause of symptoms, identify pathology, and guide effective management. Current practice rarely meets these ideals. PURPOSE This review considers recent advances in technology such as high-resolution manometry (HRM) with esophageal pressure topography (EPT), HRM with impedance, high frequency ultrasound, and endoscopic functional luminal impedance planimetry (Endo-FLIP) that provide new opportunities to identify the pathophysiologic basis of esophageal symptoms and disease. As experience with these new devices increases researchers are developing new methodologies that maximize their utility in clinical practice. For example, application of HRM to assess motility and function during and after a test meal can identify the causes of swallowing problems, reflux and other postprandial symptoms and intra-operative application of Endo-FLIP may help surgeons perform antireflux surgery. These examples illustrate the potential of physiologic measurement to direct rational and effective clinical management for individual patients.
Collapse
Affiliation(s)
- M Fox
- NIHR Biomedical Research Unit, Nottingham Digestive Diseases Centre, Queen's Medical Centre, Nottingham, UK.
| | | |
Collapse
|
93
|
Dysphagia and gastroesophageal junction resistance to flow following partial and total fundoplication. J Gastrointest Surg 2012; 16:475-85. [PMID: 21913039 DOI: 10.1007/s11605-011-1675-7] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/14/2011] [Accepted: 08/12/2011] [Indexed: 01/31/2023]
Abstract
BACKGROUND Esophageal peristalsis and basal gastroesophageal junction (GEJ) pressure correlate poorly with dysphagia. AIM To determine intraluminal pressures that reflect GEJ function and to determine manometric correlates for dysphagia before and after fundoplication. METHODS The relationships between maximal intrabolus pressure, residual GEJ relaxation pressure and peak peristaltic pressure for water swallows were determined in normal volunteers and patients with reflux disease before and after fundoplication. GEJ anatomy was assessed by radiological, endoscopic and surgical criteria, whilst dysphagia was measured with a validated composite dysphagia score. RESULTS Dysphagia was significantly associated with lower peak peristaltic pressure in the distal esophagus and the presence of a hiatus hernia preoperatively, as well as higher residual pressure on GEJ relaxation postoperatively. Peak distal peristaltic pressure and residual GEJ relaxation pressure were predictors of intrabolus pressure after total fundoplication (p<0.002). Residual GEJ relaxation pressure was four times higher after 360° fundoplication (N=19) compared to 90° fundoplication (N=14, p<0.0001). Similarly, intrabolus pressure was elevated 2.5 times after 360° fundoplication and nearly doubled after 90° fundoplication and both were significantly different from controls (N=22) and reflux disease patients (N=53, p<0.0001). CONCLUSIONS Gastroesophageal junction impedance to flow imposed by fundoplication is associated with dysphagia when there is suboptimal distal esophageal contraction strength and relatively high residual GEJ relaxation pressure.
Collapse
|
94
|
Impact of total fundoplication on esophageal transit: analysis by combined multichannel intraluminal impedance and manometry. J Clin Gastroenterol 2012; 46:e1-5. [PMID: 22157223 DOI: 10.1097/mcg.0b013e31822f3735] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
BACKGROUND Laparoscopic total fundoplication is considered the most effective surgical option for gastroesophageal reflux (GER) disease. Some authors assume that total fundoplication may expose the patient to delayed transit of the swallowed bolus and increased risk of dysphagia, particularly when peristaltic dysfunction is present. We undertook this study to evaluate by means of combined multichannel intraluminal impedance and esophageal manometry (MII-EM) the impact of fundoplication on esophageal physiology. An objective measurement of the influence of the total wrap on bolus transit may be helpful in refining the optimal antireflux wrap (ie, partial vs. total). METHODS In this study, 25 consecutive patients who underwent laparoscopic Nissen-Rossetti fundoplication had MII-EM and combined 24-hour pH and multichannel intraluminal impedance (MII-pH) before and after the surgical procedure. All patients completed preoperative and postoperative symptom questionnaires. The following were calculated for liquid and viscous deglutition lower esophageal sphincter pressure and relaxation, distal esophageal amplitude, the number of complete esophageal bolus transits and the mean total bolus transit time. The acid and nonacid GER episodes were calculated by MII-pH with the patient in both upright and recumbent positions. RESULTS The postoperative MII-EM showed an increased lower esophageal sphincter pressure (P < 0.05), whereas lower esophageal sphincter relaxation and distal esophageal amplitude did not change after surgery (P = NS). Complete esophageal bolus transits and bolus transit time did not change for liquid swallows (P = NS), but was more rapid for viscous after surgery (P < 0.05). Twenty-four hour pH monitoring confirmed the postoperative reduction of both acid and nonacid reflux (P < 0.05). CONCLUSIONS Laparoscopic Nissen-Rossetti is effective in controlling both acid and nonacid GER without impairment of esophageal function. Appropriate preoperative investigation, meticulous patient selection and correct surgical technique are extremely important in securing good results.
Collapse
|
95
|
Lenglinger J. Impedance Planimetry. Dysphagia 2012. [DOI: 10.1007/174_2012_640] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
96
|
McMahon BP, Rao SSC, Gregersen H, Kwiatek MA, Pandolfino JE, Drewes AM, Krarup AL, Lottrup C, Frøkjaer JB. Distensibility testing of the esophagus. Ann N Y Acad Sci 2011; 1232:331-40. [PMID: 21950823 DOI: 10.1111/j.1749-6632.2011.06069.x] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
The following contains commentaries on distensibility testing using the functional lumen imaging probe (FLIP); the use of the distention test of the esophageal body in the clinic diagnosis of noncardiac chest pain; the functional lumen imaging in gastroesophageal reflux disease-impaired esophagogastric junction; a multimodal pain model for the esophagus; the rationale for distensibility testing; and further developments in standardized distension protocols.
Collapse
Affiliation(s)
- Barry P McMahon
- Department of Medical Physics & Clinical Engineering and Trinity College, Adelaide & Meath Hospital, Dublin, Ireland
| | | | | | | | | | | | | | | | | |
Collapse
|
97
|
Abstract
The following presents commentaries on the interest of high-resolution manometry for understanding the anatomy and physiology of the esophagogastric junction; the subtypes of achalasia, as diagnosed by high-resolution manometry; the interest of high-resolution manometry in the evaluation of dysphagia following fundoplication; and the appropriate clinical protocol for high-resolution manometry.
Collapse
Affiliation(s)
- John O Clarke
- Division of Gastroenterology, The Johns Hopkins University Hospital, Baltimore, Maryland, USA
| | | | | |
Collapse
|
98
|
Kwiatek MA, Hirano I, Kahrilas PJ, Rothe J, Luger D, Pandolfino JE. Mechanical properties of the esophagus in eosinophilic esophagitis. Gastroenterology 2011; 140:82-90. [PMID: 20858491 PMCID: PMC3008315 DOI: 10.1053/j.gastro.2010.09.037] [Citation(s) in RCA: 270] [Impact Index Per Article: 20.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/08/2010] [Revised: 08/20/2010] [Accepted: 09/09/2010] [Indexed: 12/16/2022]
Abstract
BACKGROUND & AIMS This study aimed to analyze the mechanical properties of the esophagus in eosinophilic esophagitis (EoE) using the functional luminal imaging probe (EndoFLIP; Crospon Medical Devices, Galway, Ireland). METHODS Thirty-three EoE patients (22 male; age range, 23-67 years) and 15 controls (6 male; age range, 21-68 years) were included. Subjects were evaluated during endoscopy with the EndoFLIP probe, comprised of a compliant cylindrical bag (maximal diameter 25 mm) with 16 impedance planimetry segments. Stepwise bag distensions from 2 to 40 mL were conducted and the associated intrabag pressure and intraluminal geometry were analyzed. RESULTS The EndoFLIP clearly displayed the tubular esophageal geometry and detected esophageal narrowing and localized strictures. Stepwise distension progressively opened the esophageal lumen until a distension plateau was reached such that the narrowest cross-sectional area (CSA) of the esophagus maximized despite further increases in intra-bag pressure. The esophageal distensibility (CSA vs pressure) was reduced in EoE patients (P = .02) with the distension plateau of EoE patients substantially lower than that of controls (median: CSA 267 mm(2) vs 438 mm(2); P < .01). Mucosal eosinophil count, age, sex, and current proton pump inhibitor treatment did not predict this limiting caliber of the esophagus (P ≥ 0.20). CONCLUSIONS Esophageal distensibility, defined by the change in the narrowest measurable CSA within the distal esophagus vs intraluminal pressure was significantly reduced in EoE patients compared with controls. Measuring esophageal distensibility may be an important adjunct to the management of EoE, as it is capable of providing an objective means to measure the outcomes of medical or dilation therapy.
Collapse
|
99
|
Boeckxstaens GE. Alterations confined to the gastro-oesophageal junction: the relationship between low LOSP, TLOSRs, hiatus hernia and acid pocket. Best Pract Res Clin Gastroenterol 2010; 24:821-9. [PMID: 21126696 DOI: 10.1016/j.bpg.2010.08.011] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/26/2010] [Accepted: 08/28/2010] [Indexed: 01/31/2023]
Abstract
The gastro-oesophageal junction is a specialised segment of the gut designed to prevent reflux of gastric contents into the oesophagus. This task is fulfilled by two structures, i.e. the lower oesophageal sphincter and the crural diaphragm, which generate a high pressure zone. Especially during low pressure at the junction, as in case of long-lasting transient lower oesophageal sphincter relaxations, reflux can occur but mainly if a positive pressure gradient exists between stomach and the oesphagogastric junction. Although patients with gastro-oesophageal reflux disease have increased oesophageal acid exposure compared to controls, the number of transient relaxations is not increased compared to healthy controls. Instead, the risk to have acid reflux is at least doubled in patients, especially in those with a hiatal hernia, most likely as a result of the supradiaphragmatic position of the acid pocket. In hiatal hernia patients, the acid pocket is indeed often trapped in the hernia above the diaphragm. Which factors exactly determine the physical composition (liquid or gas) and the proximal extent of the refluxate however requires further research.
Collapse
Affiliation(s)
- Guy E Boeckxstaens
- Department of Gastroenterology, University Hospital of Leuven, Catholic University of Leuven, Belgium.
| |
Collapse
|
100
|
Kwiatek MA, Pandolfino JE, Hirano I, Kahrilas PJ. Esophagogastric junction distensibility assessed with an endoscopic functional luminal imaging probe (EndoFLIP). Gastrointest Endosc 2010; 72:272-8. [PMID: 20541755 PMCID: PMC3019759 DOI: 10.1016/j.gie.2010.01.069] [Citation(s) in RCA: 177] [Impact Index Per Article: 12.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/23/2009] [Accepted: 11/26/2009] [Indexed: 02/07/2023]
Abstract
BACKGROUND Increased esophagogastric junction (EGJ) compliance is a key abnormality in GERD leading to increased volumes of reflux. To date, EGJ distensibility has been measured only with investigational barostat-based prototype devices. OBJECTIVES The aim of the study was to test the endoscopic functional luminal imaging probe (EndoFLIP), a new commercially available technology designed to measure intraluminal distensibility, by assessing the EGJ of GERD patients and controls. DESIGN Prospective case-control series. SETTING Tertiary referral center. SUBJECTS Twenty GERD patients and 20 controls studied during a routine esophagogastroduodenoscopy. METHODS The EndoFLIP was passed through the endoscopic instrumentation channel and positioned across the EGJ. The EndoFLIP uses impedance planimetry to measure 16 cross-sectional areas (CSA) along with the corresponding intrabag pressure within a 4.6-cm cylindrical segment of a fluid-filled bag. MAIN OUTCOME MEASUREMENT EGJ distensibility was assessed with 10- to 40-mL volume-controlled distentions. RESULTS In both groups, the least distensible locus at the EGJ was usually at the hiatus. As a group, GERD patients exhibited two- to threefold increased EGJ distensibility compared with controls, particularly at 20- to 30-mL distention volumes, values quantitatively similar to previous measurements with barostat-based devices. The endoscopic estimation of EGJ distensibility, the flap valve grade, correlated poorly with EndoFLIP measurements. LIMITATIONS Heterogeneity of GERD patients. CONCLUSIONS Measurement of EGJ distensibility with EndoFLIP is feasible during clinical endoscopy. Stratifying GERD patients according to this physiological parameter may facilitate the identification of patient subgroups responsive or unresponsive to medical or surgical treatments.
Collapse
|