51
|
Ali MY, Anand SV, Tangella K, Ramkumar D, Saif TA. Isolation of Primary Human Colon Tumor Cells from Surgical Tissues and Culturing Them Directly on Soft Elastic Substrates for Traction Cytometry. J Vis Exp 2015:e52532. [PMID: 26065530 DOI: 10.3791/52532] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/31/2022] Open
Abstract
Cancer cells respond to matrix mechanical stiffness in a complex manner using a coordinated, hierarchical mechano-chemical system composed of adhesion receptors and associated signal transduction membrane proteins, the cytoskeletal architecture, and molecular motors. Mechanosensitivity of different cancer cells in vitro are investigated primarily with immortalized cell lines or murine derived primary cells, not with primary human cancer cells. Hence, little is known about the mechanosensitivity of primary human colon cancer cells in vitro. Here, an optimized protocol is developed that describes the isolation of primary human colon cells from healthy and cancerous surgical human tissue samples. Isolated colon cells are then successfully cultured on soft (2 kPa stiffness) and stiff (10 kPa stiffness) polyacrylamide hydrogels and rigid polystyrene (~3.6 GPa stiffness) substrates functionalized by an extracellular matrix (fibronectin in this case). Fluorescent microbeads are embedded in soft gels near the cell culture surface, and traction assay is performed to assess cellular contractile stresses using free open access software. In addition, immunofluorescence microscopy on different stiffness substrates provides useful information about primary cell morphology, cytoskeleton organization and vinculin containing focal adhesions as a function of substrate rigidity.
Collapse
Affiliation(s)
- M Yakut Ali
- Department of Mechanical Science and Engineering, University of Illinois at Urbana-Champaign
| | - Sandeep V Anand
- Department of Mechanical Science and Engineering, University of Illinois at Urbana-Champaign
| | - Krishnarao Tangella
- College of Medicine, University of Illinois at Urbana-Champaign; Provena Covenant Medical Centre
| | - Davendra Ramkumar
- College of Medicine, University of Illinois at Urbana-Champaign; Provena Covenant Medical Centre
| | - Taher A Saif
- Department of Mechanical Science and Engineering, University of Illinois at Urbana-Champaign; Micro and Nanotechnology Laboratory, University of Illinois at Urbana-Champaign;
| |
Collapse
|
52
|
Rapid and Localized Mechanical Stimulation and Adhesion Assay: TRPM7 Involvement in Calcium Signaling and Cell Adhesion. PLoS One 2015; 10:e0126440. [PMID: 25946314 PMCID: PMC4422584 DOI: 10.1371/journal.pone.0126440] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2014] [Accepted: 04/01/2015] [Indexed: 01/16/2023] Open
Abstract
A cell mechanical stimulation equipment, based on cell substrate deformation, and a more sensitive method for measuring adhesion of cells were developed. A probe, precisely positioned close to the cell, was capable of a vertical localized mechanical stimulation with a temporal frequency of 207 Hz, and strain magnitude of 50%. This setup was characterized and used to probe the response of Human Umbilical Endothelial Vein Cells (HUVECs) in terms of calcium signaling. The intracellular calcium ion concentration was measured by the genetically encoded Cameleon biosensor, with the Transient Receptor Potential cation channel, subfamily M, member 7 (TRPM7) expression inhibited. As TRPM7 expression also regulates adhesion, a relatively simple method for measuring adhesion of cells was also developed, tested and used to study the effect of adhesion alone. Three adhesion conditions of HUVECs on polyacrylamide gel dishes were compared. In the first condition, the substrate is fully treated with Sulfo-SANPAH crosslinking and fibronectin. The other two conditions had increasingly reduced adhesion: partially treated (only coated with fibronectin, with no use of Sulfo-SANPAH, at 5% of the normal amount) and non-treated polyacrylamide gels. The cells showed adhesion and calcium response to the mechanical stimulation correlated to the degree of gel treatment: highest for fully treated gels and lowest for non-treated ones. TRPM7 inhibition by siRNA on HUVECs caused an increase in adhesion relative to control (no siRNA treatment) and non-targeting siRNA, but a decrease to 80% of calcium response relative to non-targeting siRNA which confirms the important role of TRPM7 in mechanotransduction despite the increase in adhesion.
Collapse
|
53
|
Abstract
For many decades, fundamental cancer research has relied on two-dimensional in vitro cell culture models. However, these provide a poor representation of the complex three-dimensional (3D) architecture of living tissues. The more recent 3D culture systems, which range from ridged scaffolds to semiliquid gels, resemble their natural counterparts more closely. The arrangement of the cells in 3D systems allows better cell-cell interaction and facilitates extracellular matrix secretion, with concomitant effects on gene and protein expression and cellular behavior. Many studies have reported differences between 3D and 2D systems as regards responses to therapeutic agents and pivotal cellular processes such as cell differentiation, morphology, and signaling pathways, demonstrating the importance of 3D culturing for various cancer cell lines.
Collapse
|
54
|
Abstract
A variety of cell types exhibit phenotype changes in response to the mechanical stiffness of the substrate. Many cells excluding neurons display an increase in the spread area, actin stress fiber formation and larger focal adhesion complexes as substrate stiffness increases in a sparsely populated culture. Cell proliferation is also known to directly correlate with these phenotype changes/changes in substrate stiffness. Augmented spreading and proliferation on stiffer substrates require nuclear transcriptional regulator YAP (Yes associated protein) localization in the cell nucleus and is tightly coupled to larger traction force generation. In this study, we show that different types of fibroblasts can exhibit spread morphology, well defined actin stress fibers, and larger focal adhesions even on very soft collagen gels (modulus in hundreds of Pascals) as if they are on hard glass substrates (modulus in GPa, several orders of magnitude higher). Strikingly, we show, for the first time, that augmented spreading and other hard substrate cytoskeleton architectures on soft collagen gels are not correlated with the cell proliferation pattern and do not require YAP localization in the cell nucleus. Finally, we examine the response of human colon carcinoma (HCT-8) cells on soft collagen gels. Recent studies show that human colon carcinoma (HCT-8) cells form multicellular clusters by 2-3 days when cultured on soft polyacrylamide (PA) gels with a wide range of stiffness (0.5-50 kPa) and coated with an extracellular matrix, ECM (collagen monomer/fibronectin). These clusters show limited spreading/wetting on PA gels, form 3D structures at the edges, and eventually display a remarkable, dissociative metastasis like phenotype (MLP), i.e., epithelial to rounded morphological transition after a week of culture on PA gels only, but not on collagen monomer coated stiff polystyrene/glass where they exhibit enhanced wetting and form confluent monolayers. Here, we show that HCT-8 cell clusters also show augmented spreading/wetting on soft collagen gels and eventually form confluent monolayers as on rigid glass substrates and MLP is completely inhibited on soft collagen gels. Overall, these results suggest that cell-material interactions (soft collagen gels in this case) can induce cellular phenotype and cytoskeleton organization in a remarkably distinct manner compared to a classical synthetic polyacrylamide (PA) hydrogel cell culture model and may contribute in designing new functional biomaterials.
Collapse
Affiliation(s)
- M Yakut Ali
- Department of Mechanical Science and Engineering, College of Engineering, University of Illinois at Urbana-Champaign, Urbana, Illinois, USA61801.
| | | | | |
Collapse
|
55
|
Prauzner-Bechcicki S, Raczkowska J, Madej E, Pabijan J, Lukes J, Sepitka J, Rysz J, Awsiuk K, Bernasik A, Budkowski A, Lekka M. PDMS substrate stiffness affects the morphology and growth profiles of cancerous prostate and melanoma cells. J Mech Behav Biomed Mater 2014; 41:13-22. [PMID: 25460399 DOI: 10.1016/j.jmbbm.2014.09.020] [Citation(s) in RCA: 52] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2014] [Revised: 09/19/2014] [Accepted: 09/22/2014] [Indexed: 11/28/2022]
Abstract
A deep understanding of the interaction between cancerous cells and surfaces is particularly important for the design of lab-on-chip devices involving the use of polydimethylsiloxane (PDMS). In our studies, the effect of PDMS substrate stiffness on mechanical properties of cancerous cells was investigated in conditions where the PDMS substrate is not covered with any of extracellular matrix proteins. Two human prostate cancer (Du145 and PC-3) and two melanoma (WM115 and WM266-4) cell lines were cultured on two groups of PDMS substrates that were characterized by distinct stiffness, i.e. 0.75 ± 0.06 MPa and 2.92 ± 0.12 MPa. The results showed the strong effect on cellular behavior and morphology. The detailed analysis of chemical and physical properties of substrates revealed that cellular behavior occurs only due to substrate elasticity.
Collapse
Affiliation(s)
- Szymon Prauzner-Bechcicki
- The Henryk Niewodniczański Institute of Nuclear Physics, Polish Academy of Sciences, Radzikowskiego 152, 31-342 Kraków, Poland
| | - Joanna Raczkowska
- The Marian Smoluchowski Institute of Physics, Jagiellonian University, Reymonta 4, 30-059 Kraków, Poland
| | - Ewelina Madej
- The Marian Smoluchowski Institute of Physics, Jagiellonian University, Reymonta 4, 30-059 Kraków, Poland
| | - Joanna Pabijan
- The Henryk Niewodniczański Institute of Nuclear Physics, Polish Academy of Sciences, Radzikowskiego 152, 31-342 Kraków, Poland
| | - Jaroslav Lukes
- Czech Technical University in Prague, Faculty of Mechanical Engineering, Technicka 4, 16607 Prague, Czech Republic
| | - Josef Sepitka
- Czech Technical University in Prague, Faculty of Mechanical Engineering, Technicka 4, 16607 Prague, Czech Republic
| | - Jakub Rysz
- The Marian Smoluchowski Institute of Physics, Jagiellonian University, Reymonta 4, 30-059 Kraków, Poland
| | - Kamil Awsiuk
- The Marian Smoluchowski Institute of Physics, Jagiellonian University, Reymonta 4, 30-059 Kraków, Poland
| | - Andrzej Bernasik
- Faculty of Physics and Applied Computer Science & Academic Centre for Materials and Nanotechnology, AGH University of Science and Technology, Reymonta 19, 30-049 Kraków, Poland
| | - Andrzej Budkowski
- The Marian Smoluchowski Institute of Physics, Jagiellonian University, Reymonta 4, 30-059 Kraków, Poland
| | - Małgorzata Lekka
- The Henryk Niewodniczański Institute of Nuclear Physics, Polish Academy of Sciences, Radzikowskiego 152, 31-342 Kraków, Poland.
| |
Collapse
|
56
|
Janoštiak R, Pataki AC, Brábek J, Rösel D. Mechanosensors in integrin signaling: The emerging role of p130Cas. Eur J Cell Biol 2014; 93:445-54. [DOI: 10.1016/j.ejcb.2014.07.002] [Citation(s) in RCA: 98] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2014] [Revised: 06/11/2014] [Accepted: 07/01/2014] [Indexed: 12/17/2022] Open
|
57
|
Ali MY, Saif MTA. Substrate Stiffness Mediated Metastasis Like Phenotype of Colon Cancer Cells is Independent of Cell to Gel Adhesion. Cell Mol Bioeng 2014. [DOI: 10.1007/s12195-014-0345-8] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023] Open
|
58
|
Tang X, Tofangchi A, Anand SV, Saif TA. A novel cell traction force microscopy to study multi-cellular system. PLoS Comput Biol 2014; 10:e1003631. [PMID: 24901766 PMCID: PMC4046928 DOI: 10.1371/journal.pcbi.1003631] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2013] [Accepted: 04/03/2014] [Indexed: 11/19/2022] Open
Abstract
Traction forces exerted by adherent cells on their microenvironment can mediate many critical cellular functions. Accurate quantification of these forces is essential for mechanistic understanding of mechanotransduction. However, most existing methods of quantifying cellular forces are limited to single cells in isolation, whereas most physiological processes are inherently multi-cellular in nature where cell-cell and cell-microenvironment interactions determine the emergent properties of cell clusters. In the present study, a robust finite-element-method-based cell traction force microscopy technique is developed to estimate the traction forces produced by multiple isolated cells as well as cell clusters on soft substrates. The method accounts for the finite thickness of the substrate. Hence, cell cluster size can be larger than substrate thickness. The method allows computing the traction field from the substrate displacements within the cells' and clusters' boundaries. The displacement data outside these boundaries are not necessary. The utility of the method is demonstrated by computing the traction generated by multiple monkey kidney fibroblasts (MKF) and human colon cancerous (HCT-8) cells in close proximity, as well as by large clusters. It is found that cells act as individual contractile groups within clusters for generating traction. There may be multiple of such groups in the cluster, or the entire cluster may behave a single group. Individual cells do not form dipoles, but serve as a conduit of force (transmission lines) over long distances in the cluster. The cell-cell force can be either tensile or compressive depending on the cell-microenvironment interactions.
Collapse
Affiliation(s)
- Xin Tang
- Department of Mechanical Science and Engineering (MechSE), College of Engineering, University of Illinois at Urbana-Champaign (UIUC), Urbana, Illinois, United States of America
| | - Alireza Tofangchi
- Department of Mechanical Science and Engineering (MechSE), College of Engineering, University of Illinois at Urbana-Champaign (UIUC), Urbana, Illinois, United States of America
| | - Sandeep V. Anand
- Department of Mechanical Science and Engineering (MechSE), College of Engineering, University of Illinois at Urbana-Champaign (UIUC), Urbana, Illinois, United States of America
| | - Taher A. Saif
- Department of Mechanical Science and Engineering (MechSE), College of Engineering, University of Illinois at Urbana-Champaign (UIUC), Urbana, Illinois, United States of America
- Micro and Nanotechnology Laboratory (MNTL), University of Illinois at Urbana-Champaign (UIUC), Urbana, Illinois, United States of America
| |
Collapse
|
59
|
Tang X, Kuhlenschmidt TB, Li Q, Ali S, Lezmi S, Chen H, Pires-Alves M, Laegreid WW, Saif TA, Kuhlenschmidt MS. A mechanically-induced colon cancer cell population shows increased metastatic potential. Mol Cancer 2014; 13:131. [PMID: 24884630 PMCID: PMC4072622 DOI: 10.1186/1476-4598-13-131] [Citation(s) in RCA: 51] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2013] [Accepted: 04/02/2014] [Indexed: 12/13/2022] Open
Abstract
Background Metastasis accounts for the majority of deaths from cancer. Although tumor microenvironment has been shown to have a significant impact on the initiation and/or promotion of metastasis, the mechanism remains elusive. We previously reported that HCT-8 colon cancer cells underwent a phenotypic transition from an adhesive epithelial type (E-cell) to a rounded dissociated type (R-cell) via soft substrate culture, which resembled the initiation of metastasis. The objective of current study was to investigate the molecular and metabolic mechanisms of the E-R transition. Methods Global gene expressions of HCT-8 E and R cells were measured by RNA Sequencing (RNA-seq); and the results were further confirmed by real-time PCR. Reactive oxygen species (ROS), anoikis resistance, enzyme activity of aldehyde dehydrogenase 3 family, member A1 (ALDH3A1), and in vitro invasion assay were tested on both E and R cells. The deformability of HCT-8 E and R cells was measured by atomic force microscopy (AFM). To study the in vivo invasiveness of two cell types, athymic nude mice were intra-splenically injected with HCT-8 E or R cells and sacrificed after 9 weeks. Incidences of tumor development and metastasis were histologically evaluated and analyzed with Fisher’s exact test. Results Besides HCT-8, E-R transition on soft substrates was also seen in three other cancer cell lines (HCT116, SW480 colon and DU145 prostate cancer). The expression of some genes, such as ALDH3A1, TNS4, CLDN2, and AKR1B10, which are known to play important roles in cancer cell migration, invasion, proliferation and apoptosis, were increased in HCT-8 R cells. R cells also showed higher ALDH3A1 enzyme activity, higher ROS, higher anoikis resistance, and higher softness than E cells. More importantly, in vitro assay and in vivo animal models revealed that HCT-8 R cells were more invasive than E cells. Conclusions Our comprehensive comparison of HCT-8 E and R cells revealed differences of molecular, phenotypical, and mechanical signatures between the two cell types. To our knowledge, this is the first study that explores the molecular mechanism of E-R transition, which may greatly increase our understanding of the mechanisms of cancer mechanical microenvironment and initiation of cancer metastasis.
Collapse
Affiliation(s)
| | | | | | | | | | | | | | | | - Taher A Saif
- Department of Mechanical Science and Engineering, College of Engineering, University of Illinois at Urbana-Champaign, 206 W, Green St, Urbana 61802, Illinois, USA.
| | | |
Collapse
|
60
|
Crecea V, Graf BW, Kim T, Popescu G, Boppart SA. High Resolution Phase-Sensitive Magnetomotive Optical Coherence Microscopy for Tracking Magnetic Microbeads and Cellular Mechanics. IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS : A PUBLICATION OF THE IEEE LASERS AND ELECTRO-OPTICS SOCIETY 2014; 20:6800907. [PMID: 25400496 PMCID: PMC4228699 DOI: 10.1109/jstqe.2013.2280501] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
We present a real-time multimodal near-infrared imaging technology that tracks externally induced axial motion of magnetic microbeads in single cells in culture. The integrated multimodal imaging technique consists of phase-sensitive magnetomotive optical coherence microscopy (MM-OCM) and multiphoton microscopy (MPM).MPMis utilized for the visualization of multifunctional fluorescent and magnetic microbeads, while MM-OCM detects, with nanometer-scale sensitivity, periodic displacements of the microbeads induced by the modulation of an external magnetic field. Magnetomotive signals are measured from mouse macrophages, human breast primary ductal carcinoma cells, and human breast epithelial cells in culture, and validated with full-field phase-sensitive microscopy. This methodology demonstrates the capability for imaging controlled cell dynamics and has the potential for measuring cell biomechanical properties, which are important in assessing the health and pathological state of cells.
Collapse
Affiliation(s)
- Vasilica Crecea
- Department of Physics, University of Illinois at Urbana-Champaign, Urbana, IL 61801 USA ( )
| | - Benedikt W Graf
- University of Illinois at Urbana-Champaign, Urbana, IL 61801 USA. He is now with NinePoint Medical, Cambridge, MA 02139 USA ( )
| | - Taewoo Kim
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801 USA ( )
| | - Gabriel Popescu
- Departments of Electrical and Computer Engineering and Bioengineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801 USA ( )
| | - Stephen A Boppart
- Departments of Electrical and Computer Engineering, Bioengineering, and Internal Medicine, University of Illinois at Urbana-Champaign, Urbana, IL 61801 USA ( )
| |
Collapse
|
61
|
Mohammadi H, McCulloch CA. Impact of elastic and inelastic substrate behaviors on mechanosensation. SOFT MATTER 2014; 10:408-420. [PMID: 24652008 DOI: 10.1039/c3sm52729h] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
In this review we summarize current data on the mechanics of synthetic and naturally occurring biopolymers that are routinely employed in examination of contractility and cellular mechanosensation. We discuss the effect of physical boundaries on the mechanical behaviors of cell substrates and cellular mechanosensation. The application of contractile forces to underlying substrates enables anchorage-dependent cells to probe the physical properties of their microenvironment. Compliant substrates deform as a result of contractile forces generated by adherent cells and, in turn, the mechanical response of substrates influences numerous cellular processes. Unlike synthetic polymers that exhibit linear elastic responses to forces applied by adherent cells, naturally-occurring biopolymers exhibit non-linear, viscoelastic behavior. In turn, the viscoelastic behavior of fibrillar biopolymers may contribute to irreversible network compaction after application of cell-derived forces. Comprehensive characterization of the unusual mechanical properties of extracellular matrix proteins like collagen has provided novel insights into cell contractility and mechanosensation. We suggest that in the future, fabrication and application of novel substrates with fibrillar structures and non-linear viscoelastic behavior will be needed for a better understanding of the role of mechanosensation in many physiological and pathological processes.
Collapse
Affiliation(s)
- Hamid Mohammadi
- Matrix Dynamics Group, University of Toronto, Room 243, Fitzgerald Building, Toronto, ON M5S 3E2, Canada.
| | | |
Collapse
|
62
|
Stroka KM, Konstantopoulos K. Physical biology in cancer. 4. Physical cues guide tumor cell adhesion and migration. Am J Physiol Cell Physiol 2014; 306:C98-C109. [PMID: 24133064 PMCID: PMC3919991 DOI: 10.1152/ajpcell.00289.2013] [Citation(s) in RCA: 58] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2013] [Accepted: 10/15/2013] [Indexed: 12/13/2022]
Abstract
As tumor cells metastasize from the primary tumor location to a distant secondary site, they encounter an array of biologically and physically heterogeneous microenvironments. While it is well established that biochemical signals guide all stages of the metastatic cascade, mounting evidence indicates that physical cues also direct tumor cell behavior, including adhesion and migration phenotypes. Physical cues acting on tumor cells in vivo include extracellular matrix mechanical properties, dimensionality, and topography, as well as interstitial flow, hydrodynamic shear stresses, and local forces due to neighboring cells. State-of-the-art technologies have recently enabled us and other researchers to engineer cell microenvironments that mimic specific physical properties of the cellular milieu. Through integration of these engineering strategies, along with physics, molecular biology, and imaging techniques, we have acquired new insights into tumor cell adhesion and migration mechanisms. In this review, we focus on the extravasation and invasion stages of the metastatic cascade. We first discuss the physical role of the endothelium during tumor cell extravasation and invasion and how contractility of endothelial and tumor cells contributes to the ability of tumor cells to exit the vasculature. Next, we examine how matrix dimensionality and stiffness coregulate tumor cell adhesion and migration beyond the vasculature. Finally, we summarize how tumor cells translate and respond to physical cues through mechanotransduction. Because of the critical role of tumor cell mechanotransduction at various stages of the metastatic cascade, targeting signaling pathways involved in tumor cell mechanosensing of physical stimuli may prove to be an effective therapeutic strategy for cancer patients.
Collapse
Affiliation(s)
- Kimberly M Stroka
- Johns Hopkins Institute for NanoBioTechnology, The Johns Hopkins University, Baltimore, Maryland
| | | |
Collapse
|
63
|
Collagen as a double-edged sword in tumor progression. Tumour Biol 2013; 35:2871-82. [PMID: 24338768 PMCID: PMC3980040 DOI: 10.1007/s13277-013-1511-7] [Citation(s) in RCA: 363] [Impact Index Per Article: 33.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2013] [Accepted: 12/03/2013] [Indexed: 12/11/2022] Open
Abstract
It has been recognized that cancer is not merely a disease of tumor cells, but a disease of imbalance, in which stromal cells and tumor microenvironment play crucial roles. Extracellular matrix (ECM) as the most abundant component in tumor microenvironment can regulate tumor cell behaviors and tissue tension homeostasis. Collagen constitutes the scaffold of tumor microenvironment and affects tumor microenvironment such that it regulates ECM remodeling by collagen degradation and re-deposition, and promotes tumor infiltration, angiogenesis, invasion and migration. While collagen was traditionally regarded as a passive barrier to resist tumor cells, it is now evident that collagen is also actively involved in promoting tumor progression. Collagen changes in tumor microenvironment release biomechanical signals, which are sensed by both tumor cells and stromal cells, trigger a cascade of biological events. In this work, we discuss how collagen can be a double-edged sword in tumor progression, both inhibiting and promoting tumor progression at different stages of cancer development.
Collapse
|
64
|
Liu K, Yuan Y, Huang J, Wei Q, Pang M, Xiong C, Fang J. Improved-throughput traction microscopy based on fluorescence micropattern for manual microscopy. PLoS One 2013; 8:e70122. [PMID: 23936383 PMCID: PMC3731345 DOI: 10.1371/journal.pone.0070122] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2013] [Accepted: 06/17/2013] [Indexed: 02/05/2023] Open
Abstract
Traction force microscopy (TFM) is a quantitative technique for measuring cellular traction force, which is important in understanding cellular mechanotransduction processes. Traditional TFM has a significant limitation in that it has a low measurement throughput, commonly one per TFM dish, due to a lack of cell position information. To obtain enough cellular traction force data, an onerous workload is required including numerous TFM dish preparations and heavy cell-seeding activities, creating further difficulty in achieving identical experimental conditions among batches. In this paper, we present an improved-throughput TFM method using the well-developed microcontact printing technique and chemical modifications of linking microbeads to the gel surface to address these limitations. Chemically linking the microbeads to the gel surface has no significant influence on cell proliferation, morphology, cytoskeleton, and adhesion. Multiple pairs of force loaded and null force fluorescence images can be easily acquired by means of manual microscope with the aid of a fluorescence micropattern made by microcontact printing. Furthermore, keeping the micropattern separate from cells by using gels effectively eliminates the potential negative effect of the micropattern on the cells. This novel design greatly improves the analysis throughput of traditional TFM from one to at least twenty cells per petri dish without losing unique advantages, including a high spatial resolution of traction measurements. This newly developed method will boost the investigation of cell-matrix mechanical interactions.
Collapse
Affiliation(s)
- Kai Liu
- Academy for Advanced Interdisciplinary Studies, Peking University, Beijing, China
| | - Yuan Yuan
- Department of Mechanics and Aerospace Engineering, College of Engineering, Peking University, Beijing, China
| | - Jianyong Huang
- Academy for Advanced Interdisciplinary Studies, Peking University, Beijing, China
- Department of Mechanics and Aerospace Engineering, College of Engineering, Peking University, Beijing, China
| | - Qiong Wei
- Department of Mechanics and Aerospace Engineering, College of Engineering, Peking University, Beijing, China
| | - Mingshu Pang
- Department of Mechanics and Aerospace Engineering, College of Engineering, Peking University, Beijing, China
| | - Chunyang Xiong
- Academy for Advanced Interdisciplinary Studies, Peking University, Beijing, China
- Department of Mechanics and Aerospace Engineering, College of Engineering, Peking University, Beijing, China
- * E-mail:
| | - Jing Fang
- Academy for Advanced Interdisciplinary Studies, Peking University, Beijing, China
- Department of Mechanics and Aerospace Engineering, College of Engineering, Peking University, Beijing, China
| |
Collapse
|
65
|
Huang C, Butler PJ, Tong S, Muddana HS, Bao G, Zhang S. Substrate stiffness regulates cellular uptake of nanoparticles. NANO LETTERS 2013; 13:1611-1615. [PMID: 23484640 DOI: 10.1021/nl400033h] [Citation(s) in RCA: 78] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
Nanoparticle (NP)-bioconjugates hold great promise for more sensitive disease diagnosis and more effective anticancer drug delivery compared with existing approaches. A critical aspect in both applications is cellular internalization of NPs, which is influenced by NP properties and cell surface mechanics. Despite considerable progress in optimization of the NP-bioconjugates for improved targeting, the role of substrate stiffness on cellular uptake has not been investigated. Using polyacrylamide (PA) hydrogels as model substrates with tunable stiffness, we quantified the relationship between substrate stiffness and cellular uptake of fluorescent NPs by bovine aortic endothelial cells (BAECs). We found that a stiffer substrate results in a higher total cellular uptake on a per cell basis, but a lower uptake per unit membrane area. To obtain a mechanistic understanding of the cellular uptake behavior, we developed a thermodynamic model that predicts that membrane spreading area and cell membrane tension are two key factors controlling cellular uptake of NPs, both of which are modulated by substrate stiffness. Our experimental and modeling results not only open up new avenues for engineering NP-based cancer cell targets for more effective in vivo delivery but also contribute an example of how the physical environment dictates cellular behavior and function.
Collapse
Affiliation(s)
- Changjin Huang
- Department of Engineering Science and Mechanics, The Pennsylvania State University, University Park, Pennsylvania 16802, United States
| | | | | | | | | | | |
Collapse
|
66
|
Tang X, Wen Q, Kuhlenschmidt TB, Kuhlenschmidt MS, Janmey PA, Saif TA. Attenuation of cell mechanosensitivity in colon cancer cells during in vitro metastasis. PLoS One 2012; 7:e50443. [PMID: 23226284 PMCID: PMC3511581 DOI: 10.1371/journal.pone.0050443] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2012] [Accepted: 10/22/2012] [Indexed: 02/07/2023] Open
Abstract
Human colon carcinoma (HCT-8) cells show a stable transition from low to high metastatic state when cultured on appropriately soft substrates (21 kPa). Initially epithelial (E) in nature, the HCT-8 cells become rounded (R) after seven days of culture on soft substrate. R cells show a number of metastatic hallmarks [1]. Here, we use gradient stiffness substrates, a bio-MEMS force sensor, and Coulter counter assays to study mechanosensitivity and adhesion of E and R cells. We find that HCT-8 cells lose mechanosensitivity as they undergo E-to-R transition. HCT-8 R cells' stiffness, spread area, proliferation and migration become insensitive to substrate stiffness in contrast to their epithelial counterpart. They are softer, proliferative and migratory on all substrates. R cells show negligible cell-cell homotypic adhesion, as well as non-specific cell-substrate adhesion. Consequently they show the same spread area on all substrates in contrast to E cells. Taken together, these results indicate that R cells acquire autonomy and anchorage independence, and are thus potentially more invasive than E cells. To the best of our knowledge, this is the first report of quantitative data relating changes in cancer cell adhesion and stiffness during the expression of an in vitro metastasis-like phenotype.
Collapse
Affiliation(s)
- Xin Tang
- Department of Mechanical Science and Engineering, College of Engineering, University of Illinois at Urbana-Champaign, Urbana, Illinois, United States of America
| | - Qi Wen
- Departments of Physiology, Physics, and Bioengineering, Institute for Medicine and Engineering, University of Pennsylvania, Philadelphia, Pennsylvania, United States of America
| | - Theresa B. Kuhlenschmidt
- Department of Pathobiology, College of Veterinary Medicine, University of Illinois at Urbana-Champaign, Urbana, Illinois, United States of America
| | - Mark S. Kuhlenschmidt
- Department of Pathobiology, College of Veterinary Medicine, University of Illinois at Urbana-Champaign, Urbana, Illinois, United States of America
| | - Paul A. Janmey
- Departments of Physiology, Physics, and Bioengineering, Institute for Medicine and Engineering, University of Pennsylvania, Philadelphia, Pennsylvania, United States of America
| | - Taher A. Saif
- Department of Mechanical Science and Engineering, College of Engineering, University of Illinois at Urbana-Champaign, Urbana, Illinois, United States of America
- Micro and Nanotechnology Laboratory (MNTL), University of Illinois at Urbana-Champaign, Urbana, Illinois, United States of America
| |
Collapse
|
67
|
Torzilli PA, Bourne JW, Cigler T, Vincent CT. A new paradigm for mechanobiological mechanisms in tumor metastasis. Semin Cancer Biol 2012; 22:385-95. [PMID: 22613484 PMCID: PMC3445741 DOI: 10.1016/j.semcancer.2012.05.002] [Citation(s) in RCA: 44] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2012] [Accepted: 05/13/2012] [Indexed: 12/24/2022]
Abstract
Tumor metastases and epithelial to mesenchymal transition (EMT) involve tumor cell invasion and migration through the dense collagen-rich extracellular matrix surrounding the tumor. Little is neither known about the mechanobiological mechanisms involved in this process, nor the role of the mechanical forces generated by the cells in their effort to invade and migrate through the stroma. In this paper we propose a new fundamental mechanobiological mechanism involved in cancer growth and metastasis, which can be both protective or destructive depending on the magnitude of the forces generated by the cells. This new mechanobiological mechanism directly challenges current paradigms that are focused mainly on biological and biochemical mechanisms associated with tumor metastasis. Our new mechanobiological mechanism describes how tumor expansion generates mechanical forces within the stroma to not only resist tumor expansion but also inhibit or enhance tumor invasion by, respectively, inhibiting or enhancing matrix metalloproteinase (MMP) degradation of the tensed interstitial collagen. While this mechanobiological mechanism has not been previously applied to the study of tumor metastasis and EMT, it may have the potential to broaden our understanding of the tumor invasive process and assist in developing new strategies for preventing or treating cancer metastasis.
Collapse
Affiliation(s)
- Peter A Torzilli
- Tissue Engineering, Regeneration and Repair Program, Hospital for Special Surgery, New York, NY 10021, United States.
| | | | | | | |
Collapse
|
68
|
Tang X, Ali MY, Saif MTA. A Novel Technique for Micro-patterning Proteins and Cells on Polyacrylamide Gels. SOFT MATTER 2012; 8:7197-7206. [PMID: 23002394 PMCID: PMC3447741 DOI: 10.1039/c2sm25533b] [Citation(s) in RCA: 52] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
Spatial patterning of proteins (extracellular matrix, ECM) for living cells on polyacrylamide (PA) hydrogels has been technically challenging due to the compliant nature of the hydrogels and their aqueous environment. Traditional micro-fabrication process is not applicable. Here we report a simple, novel and general method to pattern a variety of commonly used cell adhesion molecules, i.e. Fibronectin (FN), Laminin (LN) and Collagen I (CN), etc. on PA gels. The pattern is first printed on a hydrophilic glass using polydimethylsiloxane (PDMS) stamp and micro-contact printing (μCP). Pre-polymerization solution is applied on the patterned glass and is then sandwiched by a functionalized glass slide, which covalently binds to the gel. The hydrophilic glass slide is then peeled off from the gel when the protein patterns detach from the glass, but remain intact with the gel. The pattern is thus transferred to the gel. The mechanism of pattern transfer is studied in light of interfacial mechanics. It is found that hydrophilic glass offers strong enough adhesion with ECM proteins such that a pattern can be printed, but weak enough adhesion such that they can be completely peeled off by the polymerized gel. This balance is essential for successful pattern transfer. As a demonstration, lines of FN, LN and CN with widths varying from 5-400 μm are patterned on PA gels. Normal fibroblasts (MKF) are cultured on the gel surfaces. The cell attachment and proliferation are confined within these patterns. The method avoids the use of any toxic chemistry often used to pattern different proteins on gel surfaces.
Collapse
Affiliation(s)
- Xin Tang
- Department of Mechanical Science and Engineering, College of Engineering, University of Illinois at Urbana-Champaign, Urbana, Illinois, USA, 61801
| | - M. Yakut Ali
- Department of Mechanical Science and Engineering, College of Engineering, University of Illinois at Urbana-Champaign, Urbana, Illinois, USA, 61801
| | - M. Taher A. Saif
- Department of Mechanical Science and Engineering, College of Engineering, University of Illinois at Urbana-Champaign, Urbana, Illinois, USA, 61801
- Micro and Nanotechnology Laboratory, University of Illinois at Urbana-Champaign, Urbana, Illinois, USA, 61801
| |
Collapse
|
69
|
Kraning-Rush CM, Carey SP, Califano JP, Reinhart-King CA. Quantifying Traction Stresses in Adherent Cells. Methods Cell Biol 2012; 110:139-78. [DOI: 10.1016/b978-0-12-388403-9.00006-0] [Citation(s) in RCA: 53] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
70
|
Waters CM, Roan E, Navajas D. Mechanobiology in lung epithelial cells: measurements, perturbations, and responses. Compr Physiol 2012; 2:1-29. [PMID: 23728969 PMCID: PMC4457445 DOI: 10.1002/cphy.c100090] [Citation(s) in RCA: 46] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Epithelial cells of the lung are located at the interface between the environment and the organism and serve many important functions including barrier protection, fluid balance, clearance of particulate, initiation of immune responses, mucus and surfactant production, and repair following injury. Because of the complex structure of the lung and its cyclic deformation during the respiratory cycle, epithelial cells are exposed to continuously varying levels of mechanical stresses. While normal lung function is maintained under these conditions, changes in mechanical stresses can have profound effects on the function of epithelial cells and therefore the function of the organ. In this review, we will describe the types of stresses and strains in the lungs, how these are transmitted, and how these may vary in human disease or animal models. Many approaches have been developed to better understand how cells sense and respond to mechanical stresses, and we will discuss these approaches and how they have been used to study lung epithelial cells in culture. Understanding how cells sense and respond to changes in mechanical stresses will contribute to our understanding of the role of lung epithelial cells during normal function and development and how their function may change in diseases such as acute lung injury, asthma, emphysema, and fibrosis.
Collapse
|
71
|
Nishitani WS, Saif TA, Wang Y. Calcium signaling in live cells on elastic gels under mechanical vibration at subcellular levels. PLoS One 2011; 6:e26181. [PMID: 22053183 PMCID: PMC3203865 DOI: 10.1371/journal.pone.0026181] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2011] [Accepted: 09/21/2011] [Indexed: 12/22/2022] Open
Abstract
A new device was designed to generate a localized mechanical vibration of flexible gels where human umbilical vein endothelial cells (HUVECs) were cultured to mechanically stimulate these cells at subcellular locations. A Fluorescence Resonance Energy Transfer (FRET)-based calcium biosensor (an improved Cameleon) was used to monitor the spatiotemporal distribution of intracellular calcium concentrations in the cells upon this mechanical stimulation. A clear increase in intracellular calcium concentrations over the whole cell body (global) can be observed in the majority of cells under mechanical stimulation. The chelation of extracellular calcium with EGTA or the blockage of stretch-activated calcium channels on the plasma membrane with streptomycin or gadolinium chloride significantly inhibited the calcium responses upon mechanical stimulation. Thapsigargin, an endoplasmic reticulum (ER) calcium pump inhibitor, or U73122, a phospholipase C (PLC) inhibitor, resulted in mainly local calcium responses occurring at regions close to the stimulation site. The disruption of actin filaments with cytochalasin D or inhibition of actomyosin contractility with ML-7 also inhibited the global calcium responses. Therefore, the global calcium response in HUVEC depends on the influx of calcium through membrane stretch-activated channels, followed by the release of inositol trisphosphate (IP3) via PLC activation to trigger the ER calcium release. Our newly developed mechanical stimulation device can also provide a powerful tool for the study of molecular mechanism by which cells perceive the mechanical cues at subcellular levels.
Collapse
Affiliation(s)
- Wagner Shin Nishitani
- Department of Bioengineering and Beckman Institute for Advanced Science and Technology, University of Illinois, Urbana-Champaign, Urbana, Illinois, United States of America
- The Capes Foundation, Ministry of Education of Brazil, Brasília, Distrito Federal, Brazil
| | - Taher A. Saif
- Department of Mechanical Science and Engineering, University of Illinois, Urbana-Champaign, Urbana, Illinois, United States of America
- * E-mail: (YW); (TAS)
| | - Yingxiao Wang
- Department of Bioengineering and Beckman Institute for Advanced Science and Technology, University of Illinois, Urbana-Champaign, Urbana, Illinois, United States of America
- Integrative and Molecular Physiology, Center for Biophysics and Computational Biology, Institute for Genomic Biology, University of Illinois, Urbana-Champaign, Urbana, Illinois, United States of America
- * E-mail: (YW); (TAS)
| |
Collapse
|
72
|
Shieh AC. Biomechanical forces shape the tumor microenvironment. Ann Biomed Eng 2011; 39:1379-89. [PMID: 21253819 DOI: 10.1007/s10439-011-0252-2] [Citation(s) in RCA: 103] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2010] [Accepted: 01/12/2011] [Indexed: 12/17/2022]
Abstract
The importance of the tumor microenvironment in cancer progression is indisputable, yet a key component of the microenvironment--biomechanical forces--remains poorly understood. Tumor growth and progression is paralleled by a host of physical changes in the tumor microenvironment, such as growth-induced solid stresses, increased matrix stiffness, high fluid pressure, and increased interstitial flow. These changes to the biomechanical microenvironment promote tumorigenesis and tumor cell invasion and induce stromal cells--such as fibroblasts, immune cells, and endothelial cells--to change behavior and support cancer progression. This review highlights what we currently know about the biomechanical forces generated in the tumor microenvironment, how they arise, and how these forces can dramatically influence cell behavior, drawing not only upon studies directly related to cancer and tumor cells, but also work in other fields that have shown the effects of these types of mechanical forces vis-à-vis cell behaviors relevant to the tumor microenvironment. By understanding how all of these biomechanical forces can affect tumor cells, stromal cells, and tumor-stromal crosstalk, as well as alter how tumor and stromal cells perceive other extracellular signals in the tumor microenvironment, we can develop new approaches for diagnosis, prognosis, and ultimately treatment of cancer.
Collapse
Affiliation(s)
- Adrian C Shieh
- School of Biomedical Engineering, Science and Health Systems, Drexel University, 3141 Chestnut Street, Philadelphia, PA 19104-2875, USA.
| |
Collapse
|
73
|
Pathak A, Kumar S. Biophysical regulation of tumor cell invasion: moving beyond matrix stiffness. Integr Biol (Camb) 2011; 3:267-78. [DOI: 10.1039/c0ib00095g] [Citation(s) in RCA: 161] [Impact Index Per Article: 12.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
|