51
|
Yazar O, Mees BME, Provoost AL, Ketting S, de Haan MW, Schurink GWH. Comparing Mobile C-Arm with a Hybrid Operating Room for Imaging in Fenestrated Stent-Graft Endovascular Abdominal Aortic Aneurysm Repair. Ann Vasc Surg 2020; 68:261-269. [PMID: 32283306 DOI: 10.1016/j.avsg.2020.04.002] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2020] [Revised: 03/29/2020] [Accepted: 04/01/2020] [Indexed: 11/16/2022]
Abstract
BACKGROUND To evaluate the advantages of a hybrid operating room (OR) (group 2) compared with a fluoroscopic mobile C-arm (group 1) during fenestrated stent-graft endovascular aneurysm repair (f-EVAR). METHODS This single-center study retrospectively analyzed prospectively collected data of consecutive patients treated with f-EVAR for short-necked, juxtarenal, and suprarenal aortic aneurysms between January 2006 and July 2016. Primary end points were technical success and perioperative complications. Secondary end points included 30-day and 1-year mortality as well as target vessel patency. RESULTS About 96 patients were treated (85 men; 74.1 ± 6.3 years); 46 patients (48%) belonging to group 1 and 50 (52%) patients belonging to group 2. Technical success was achieved in 92.7% of the procedures (group 1 91.3% vs. group 2 94%, P = 0.72). Significantly more complex interventions were performed in group 2 (n = 38 of 50) compared with group 1 (n = 14 of 46; P < 0.001), in which primarily renal f-EVAR interventions were performed. In group 2, significantly less contrast was used (median 150 mL vs. 100 mL; P < 0.001). The 30-day mortality in group 1 was 9% and 2% in group 2 (P = 0.14), and 1-year survival was also not significantly different between both groups. Target visceral vessel primary patency was significantly higher in group 1 (87.6% vs. 85.5% [P = 0.006] and 83.8% vs. 78.3% [P = 0.03]) at 6 and 12 months, respectively). There was no significant difference in renal artery primary patency at 6 and 12 months. CONCLUSIONS Immediate and 1-year outcomes after f-EVAR for abdominal aortic aneurysm were comparable using a hybrid OR compared with a mobile C-arm, despite the use of significantly more complex stent grafts in the patients treated in the hybrid OR. The use of a hybrid OR may assist in achieving satisfying results in complex f-EVAR.
Collapse
Affiliation(s)
- Ozan Yazar
- Department of Vascular Surgery, Zuyderland Medical Center, Heerlen, The Netherlands
| | - Barend M E Mees
- Department of Vascular Surgery, Maastricht University Medical Center, Maastricht, The Netherlands; Department of Vascular Surgery, European Vascular Center Aachen-Maastricht, University Hospital Aachen, Aachen, Germany
| | - An-Lies Provoost
- Department of Vascular Surgery, Maastricht University Medical Center, Maastricht, The Netherlands
| | - Shirley Ketting
- Department of Vascular Surgery, Maastricht University Medical Center, Maastricht, The Netherlands
| | - Michiel W de Haan
- Department of Radiology, Maastricht University Medical Center, Maastricht, The Netherlands
| | - Geert Willem H Schurink
- Department of Vascular Surgery, Maastricht University Medical Center, Maastricht, The Netherlands; Department of Vascular Surgery, European Vascular Center Aachen-Maastricht, University Hospital Aachen, Aachen, Germany.
| |
Collapse
|
52
|
Steffen M, Schmitz-Rixen T, Böckler D, Grundmann RT. Comparison of open and endovascular repair of juxtarenal abdominal aortic aneurysms. Langenbecks Arch Surg 2020; 405:207-213. [PMID: 32266530 DOI: 10.1007/s00423-020-01865-4] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2019] [Accepted: 03/16/2020] [Indexed: 01/26/2023]
Abstract
BACKGROUND This study compares the perioperative outcome in elective repair of the juxtarenal abdominal aortic aneurysm (AAA), depending upon whether patients received an open (OAR) or endovascular procedure (EVAR). METHODS The database stems from the 2013-2017 AAA registry of the German Institute for Vascular Health Research (DIGG) of the German Society for Vascular Surgery and Vascular Medicine (DGG), with a total of 1603 juxtarenal AAAs. 786 patients (49.0%) were treated with an endovascular (EVAR) procedure, and 817 (51.0%) with an open (OAR) procedure. RESULTS Patients receiving EVAR had a median age of 73 years and those receiving OAR a median age of 71 years (p < 0.001). The proportion of patients over 80 years of age was 17.0% for EVAR and 9.9% for OAR (p < 0.001). The proportion of women receiving EVAR (16.9%) was slightly lower than that receiving OAR (18.6%). Aneurysm diameter differed significantly (EVAR mean 57.80 mm, OAR 59.07 mm; p = 0.038). Preoperatively impaired renal function stages 3 to 5 were not significantly different (EVAR 12.5%, OAR 14.4%, p = 0.158). Postoperative complications were significantly less with EVAR (31%) than with OAR at 45.7% (p = 0.001). In regard to MACE (major adverse cardiac events = perioperative death, stroke, or myocardial infarction), there were no significant differences between EVAR (8.8%) and OAR (10.3%) (p = 0.191). Hospital mortality was only in trend lower with EVAR than with OAR (5.7% vs. 7.7%, respectively; p = 0.068). This held true for the hospital mortality in the group above 80 years of age as well. Inpatient stay was 9 (13.3) days for EVAR and 14 (18.8) days for OAR (p < 0.001). The hospital mortality for women receiving EVAR was 10.5%, and significantly higher (p = 0.008) than that for men (4.7%). The same held true for OAR (hospital mortality for women was 11.8%, for men 6.8%; p = 0.030). CONCLUSION In terms of perioperative outcome, the endovascular procedure for treating juxtarenal AAA is more favorable than that documented for OAR. Further investigation is necessary to determine whether EVAR is comparable with OAR in the long term when treating juxtarenal AAA.
Collapse
Affiliation(s)
- M Steffen
- Klinikum Saarbrücken gGmbH, Winterberg 1, 66119, Saarbrücken, Germany
| | - Thomas Schmitz-Rixen
- Department of Vascular and Endovascular Surgery and the University Wound Center, University Hospital, Frankfurt am Main, Germany
| | - D Böckler
- Department of Vascular and Endovascular Surgery, University Hospital, Heidelberg, Germany
| | - Reinhart T Grundmann
- German Institute for Vascular Health Research (DIGG) of the German Society of Vascular Surgery and Vascular Medicine, Berlin, Germany.
| | | |
Collapse
|
53
|
Hemmler A, Lin A, Thierfelder N, Franz T, Gee MW, Bezuidenhout D. Customized stent-grafts for endovascular aneurysm repair with challenging necks: A numerical proof of concept. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2020; 36:e3316. [PMID: 32022404 DOI: 10.1002/cnm.3316] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/12/2019] [Revised: 12/05/2019] [Accepted: 01/23/2020] [Indexed: 06/10/2023]
Abstract
Endovascular aortic repair (EVAR) is a challenging intervention whose long-term success strongly depends on the appropriate stent-graft (SG) selection and sizing. Most off-the-shelf SGs are straight and cylindrical. Especially in challenging vessel morphologies, the morphology of off-the-shelf SGs is not able to meet the patient-specific demands. Advanced manufacturing technologies facilitate the development of highly customized SGs. Customized SGs that have the same morphology as the luminal vessel surface could considerably improve the quality of the EVAR outcome with reduced likelihoods of EVAR related complications such as endoleaks type I and SG migration. In this contribution, we use an in silico EVAR methodology that approximates the deployed state of the elastically deformable SG in a hyperelastic, anisotropic vessel. The in silico EVAR results of off-the-shelf SGs and customized SGs are compared qualitatively and quantitatively in terms of mechanical and geometrical parameters such as stent stresses, contact tractions, SG fixation forces and the SG-vessel attachment. In a numerical proof of concept, eight different vessel morphologies, such as a conical vessel, a barrel shaped vessel and a curved vessel, are used to demonstrate the added value of customized SGs compared to off-the-shelf SGs. The numerical investigation has shown large benefits of the highly customized SGs compared to off-the-shelf SGs with respect to a better SG-vessel attachment and a considerable increase in SG fixation forces of up to 50% which indicate decreased likelihoods of EVAR related complications. Hence, this numerical proof of concept motivates further research and development of highly customized SGs for the use in challenging vessel morphologies.
Collapse
Affiliation(s)
- André Hemmler
- Mechanics & High Performance Computing Group, Technische Universität München, Garching bei München, Germany
| | - Andrew Lin
- Chris Barnard Division of Cardiothoracic Surgery, University of Cape Town, Observatory, South Africa
| | - Nikolaus Thierfelder
- Herzchirurgische Klinik und Poliklinik, Ludwig-Maximilians-Universität München, München, Germany
| | - Thomas Franz
- Division of Biomedical Engineering, Department of Human Biology, University of Cape Town, Observatory, South Africa
| | - Michael W Gee
- Mechanics & High Performance Computing Group, Technische Universität München, Garching bei München, Germany
| | - Deon Bezuidenhout
- Chris Barnard Division of Cardiothoracic Surgery, University of Cape Town, Observatory, South Africa
| |
Collapse
|
54
|
Yao C, Ning J, Li Z, Wang M, Wu R, Wang S, Chang G. Parallel Covered Stents Technique in the Treatment of Abdominal Aortic Diseases. J Vasc Interv Radiol 2020; 31:771-777. [PMID: 32127313 DOI: 10.1016/j.jvir.2019.09.022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2019] [Revised: 09/23/2019] [Accepted: 09/24/2019] [Indexed: 11/17/2022] Open
Abstract
PURPOSE To investigate the safety and efficacy of the parallel covered stents technique in the treatment of anatomically challenging aortic aneurysms, pseudoaneurysms, and dissections. MATERIALS AND METHODS Data were retrospectively collected from 16 patients with abdominal aortic diseases who were treated with parallel covered stents (Gore Excluder, n = 14; Medtronic Endurant, n = 2) between January 2016 and July 2018. Patients were treated with this technique if they were unsuitable for either open repair or standard endovascular aortic repair with bifurcated stents. Such unfavorable anatomy included narrow aortic necks (≤18 mm), small vascular access (occluded or ≤6.0 mm), or compressed aortic lumens (≤18 mm). All patients were male, with a mean age of 64.7 ± 13.3 years. For true aneurysms (n = 4) and pseudoaneurysms (n = 4), the mean diameter and length of the proximal necks were 17.5 ± 2.6 mm (range, 14-21 mm) and 51.0 ± 12.5 mm (range, 39-75 mm), respectively. The minimal diameter of true lumen in cases with aortic dissection and penetrating ulcers (n = 8) was 14.8 ± 3.1 mm. Small or occluded femoral access was found in 3 patients. RESULTS Technical success was 100%. Minor type I endoleaks, which were seen on completion angiography in 5 patients, had all resolved within 3 months. There were no perioperative deaths. Postoperative complications included supraventricular tachycardia in 1 patient and pneumonia combined with heart failure in 1 patient. Patency of all stents was observed at a mean follow-up of 21.8 ± 10.1 months. CONCLUSIONS The parallel covered stents technique appears to offer a feasible solution for abdominal aortic diseases with unfavorable anatomy. Long-term follow-up is needed to further evaluate the safety and efficacy of this technique.
Collapse
Affiliation(s)
- Chen Yao
- Department of Vascular Surgery, The First Affiliated Hospital, Sun Yat-sen University, 58 Zhongshan 2nd Road, Guangzhou 510080, China
| | - Junjie Ning
- Department of Vascular Surgery, The First Affiliated Hospital, Sun Yat-sen University, 58 Zhongshan 2nd Road, Guangzhou 510080, China
| | - Zilun Li
- Department of Vascular Surgery, The First Affiliated Hospital, Sun Yat-sen University, 58 Zhongshan 2nd Road, Guangzhou 510080, China
| | - Mian Wang
- Department of Vascular Surgery, The First Affiliated Hospital, Sun Yat-sen University, 58 Zhongshan 2nd Road, Guangzhou 510080, China
| | - Ridong Wu
- Department of Vascular Surgery, The First Affiliated Hospital, Sun Yat-sen University, 58 Zhongshan 2nd Road, Guangzhou 510080, China
| | - Shenming Wang
- Department of Vascular Surgery, The First Affiliated Hospital, Sun Yat-sen University, 58 Zhongshan 2nd Road, Guangzhou 510080, China
| | - Guangqi Chang
- Department of Vascular Surgery, The First Affiliated Hospital, Sun Yat-sen University, 58 Zhongshan 2nd Road, Guangzhou 510080, China.
| |
Collapse
|
55
|
Končar IB, Jovanović AL, Dučič SM. The role of fEVAR, chEVAR and open repair in treatment of juxtarenal aneurysms: a systematic review. THE JOURNAL OF CARDIOVASCULAR SURGERY 2020; 61:24-36. [PMID: 32079378 DOI: 10.23736/s0021-9509.19.11187-1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
INTRODUCTION Open repair (OR), fenestrated endovascular aneurysm repair (fEVAR) and endovascular exclusion using parallel graft (chEVAR) are complementary procedures used for treatment of juxtarenal abdominal aortic aneurysm (jrAAA). The aim of our study was to assess available literature and analyze dispersion of OR, fEVAR and chEVAR procedures among reported papers related to treatment of jrAAA. EVIDENCE ACQUISITION The PubMed database was systematically searched using predefined strategy and key words related to treatment of jrAAA on September 28th, 2019. Studies were assessed for eligibility using the inclusion and exclusion criteria with at least five patients treated with at least one of the procedures while systematic reviews, meta-analysis, reviews, comments, editorials and letters were excluded as well as studies without clear classification of the location of the aneurysm, studies not specifying the number of patients treated with each of the techniques or not discriminated between aortic pathologies (juxtarenal, paravisceral and thoracoabdominal), hybrid procedures, endoanchors or with branched stent-graft. EVIDENCE SYNTHESIS Overall, 1533 papers were identified while papers that met inclusion criteria were either representing experience of single institution (87 papers) or from multicenter studies (6 papers), national or international registries (18 papers). In the period between January 1977 and December 2017, treatment of 5664 patients with jrAAA was reported in 87 papers as a single institution report. Out of them 2531 (45%) were treated with OR, 2592 (46%) with fEVAR and 541 (9%) with chEVAR. Out of 29 institutions reporting OR, there were 11 (37.9%) with more than 100 treated patients while 21 (41.1%) out of 51 institutions that reported more than 50 jrAAA treated with fEVAR. Only four institutions reported results of all three treatment modalities. CONCLUSIONS Based on the results reported in the literature, regardless of its complexity and costs, fEVAR for jrAAA has been accepted in substantial number of hospitals worldwide, while number of reported procedures is reaching OR.
Collapse
Affiliation(s)
- Igor B Končar
- Clinic for Vascular and Endovascular Surgery, Serbian Clinical Center, Belgrade, Serbia - .,Faculty of Medicine, University of Belgrade, Belgrade, Serbia -
| | - Aleksa L Jovanović
- Faculty of Medicine, University of Belgrade, Belgrade, Serbia.,Institute of Epidemiology, Faculty of Medicine, University of Belgrade, Belgrade, Serbia
| | - Stefan M Dučič
- Clinic for Vascular and Endovascular Surgery, Serbian Clinical Center, Belgrade, Serbia
| |
Collapse
|
56
|
Mohamed N, Galyfos G, Anastasiadou C, Sachmpatzidis I, Kikiras K, Papapetrou A, Giannakakis S, Kastrisios G, Papacharalampous G, Geroulakos G, Maltezos C. Fenestrated Endovascular Repair for Pararenal or Juxtarenal Abdominal Aortic Aneurysms: a Systematic Review. Ann Vasc Surg 2020; 63:399-408. [DOI: 10.1016/j.avsg.2019.09.016] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2019] [Revised: 09/12/2019] [Accepted: 09/12/2019] [Indexed: 12/20/2022]
|
57
|
Henstra L, Yazar O, de Niet A, Tielliu IF, Schurink GW, Zeebregts CJ. Outcome of Fenestrated Endovascular Aneurysm Repair in Octogenarians: A Retrospective Multicentre Analysis. Eur J Vasc Endovasc Surg 2020; 59:24-30. [DOI: 10.1016/j.ejvs.2019.06.002] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2018] [Revised: 05/04/2019] [Accepted: 06/04/2019] [Indexed: 10/25/2022]
|
58
|
Derycke L, Sénémaud J, Perrin D, Avril S, Desgranges P, Albertini JN, Cochennec F, Haulon S. Patient Specific Computer Modelling for Automated Sizing of Fenestrated Stent Grafts. Eur J Vasc Endovasc Surg 2019; 59:237-246. [PMID: 31865026 DOI: 10.1016/j.ejvs.2019.10.009] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2019] [Revised: 09/26/2019] [Accepted: 10/16/2019] [Indexed: 10/25/2022]
Abstract
OBJECTIVE The aim was to validate a computational patient specific model of Zenith® fenestrated device deployment in abdominal aortic aneurysms to predict fenestration positions. METHODS This was a retrospective analysis of the accuracy of numerical simulation for fenestrated stent graft sizing. Finite element computational simulation was performed in 51 consecutive patients that underwent successful endovascular repair with Zenith® fenestrated stent grafts in two vascular surgery units with a high volume of aortic procedures. Longitudinal and rotational clock positions of fenestrations were measured on the simulated models. These measurements were compared with those obtained by (i) an independent observer on the post-operative computed tomography (CT) scan and (ii) by the stent graft manufacturer planning team on the pre-operative CT scan. (iii) Pre- and post-operative positions were also compared. Longitudinal distance and clock face discrepancies >3 mm and 15°, respectively, were considered significant. Reproducibility was assessed using Bland-Altman and linear regression analysis. RESULTS A total of 195 target arteries were analysed. Both Bland-Altman and linear regression showed good reproducibility between the three measurement techniques performed. The median absolute difference between the simulation and post-operative CT scan was 1.0 ± 1.1 mm for longitudinal distance measurements and 6.9 ± 6.1° for clock positions. The median absolute difference between the planning centre and post-operative CT scan was 0.8 ± 0.8 mm for longitudinal distance measurements and 5.1 ± 5.0° for clock positions. Finally, the median absolute difference between the simulation and the planning centre was 0.96 ± 0.97 mm for longitudinal distance measurements and 4.8 ± 3.6° for clock positions. CONCLUSION The numerical model of deployed fenestrated stent grafts is accurate for planning position of fenestrations. It has been validated in 51 patients, for whom fenestration locations were similar to the sizing performed by physicians and the planning centre.
Collapse
Affiliation(s)
- Lucie Derycke
- Mines Saint-Etienne, Univ Lyon, Univ Jean Monnet, INSERM, U 1059 Sainbiose, Centre CIS, F - 42023 Saint-Etienne, France; Department of Vascular Surgery, Henri Mondor Hospital, University of Paris XII, Créteil, France.
| | - Jean Sénémaud
- Department of Vascular Surgery, Henri Mondor Hospital, University of Paris XII, Créteil, France
| | | | - Stephane Avril
- Mines Saint-Etienne, Univ Lyon, Univ Jean Monnet, INSERM, U 1059 Sainbiose, Centre CIS, F - 42023 Saint-Etienne, France
| | - Pascal Desgranges
- Department of Vascular Surgery, Henri Mondor Hospital, University of Paris XII, Créteil, France
| | - Jean-Noel Albertini
- Department of Cardio-Vascular Surgery, Centre Hospitalier Régional Universitaire de Saint-Etienne, Saint-Priez-en-Jarez, France
| | - Frederic Cochennec
- Department of Vascular Surgery, Henri Mondor Hospital, University of Paris XII, Créteil, France
| | - Stephan Haulon
- Department of Aortic and Vascular Surgery, Marie Lannelongue Hospital, Le Plessis-Robinson, INSERM UMR_S 999, Université Paris Sud, France
| |
Collapse
|
59
|
Gargiulo M, Gallitto E, Pini R, Giordano J, Mascoli C, Sonetto A, Logiacco A, Ancetti S, Faggioli G. Fenestrated endografting is the preferred option for juxta-renal aortic aneurysm reconstruction. THE JOURNAL OF CARDIOVASCULAR SURGERY 2019; 61:2-9. [PMID: 31833736 DOI: 10.23736/s0021-9509.19.11185-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
BACKGROUND The aim of this study was to report early/mid-term-up outcomes of fenestrated endografting (FEVAR) for juxta-renal aneurysms (j-AAAs). METHODS Between 2008 and 2019, all consecutive j-AAAs treated by FEVAR were prospectively collected and retrospectively analyzed. Early endpoints were technical success, renal function worsening and 30-day mortality. Follow-up endpoints were survival, freedom from re-interventions (FFRs) and target visceral vessels (TVVs) patency. RESULTS Among 240 cases of FB-EVAR, 98(41%) were j-AAAs. Endografts with 1,2,3,4 and 5 fenestrations were planned in 3(3%), 25(26%), 35(36%), 33(34%) and 2(1%) cases, respectively. Overall, 360 TVVs were treated by fenestrations and scallops. Technical success was achieved in 97(99%) cases. The only failure was 1 type III endoleak requiring renal artery relining. No TVVs were lost. Renal function worsening was reported in 22(22%) and 12(12%) cases at 24-hour and 30-day, respectively. One patient required hemodialysis and died within 30-day (1%). This was the only case of 30-day mortality. The mean follow-up was 36±32months. Aneurysm sac shrinkage or stability was observed in 55(56%) and 41(42%) cases, respectively. Two (2%) patients with persistent type II endoleak had sac enlargement and required re-interventions. Freedom from reinterventions at 5-year was 86%. An asymptomatic celiac trunk occlusion (accommodated by a scallop) occurred at 24-month in a case with a severe preoperative stenosis. No late renal arteries occlusions or type I-III endoleaks occurred. TVVs-patency was 96% at 5-year. Renal function worsening was reported in 10(10%) patients during follow-up. Survival at 5-year was 73%, with no j-AAA related mortality. Chronic obstructive pulmonary disease (COPD) (P=0.007; OR:4.8; 95% CI: 1.5-15.3) and postoperative renal function worsening (P=0.028; OR:1,1; 95% CI: 1.1-1.2) were independent predictor for mortality at the multivariate analysis. CONCLUSIONS FEVAR for j-AAAs is safe and effective at early and long-term follow-up. According with these results, it could be proposed as the first line treatment in high risk patients if anatomically fit. Long term survival is reduced in the presence of preoperative COPD and postoperative renal function worsening.
Collapse
Affiliation(s)
- Mauro Gargiulo
- Unit of Vascular Surgery, Department of Experimental, Diagnostic and Specialty Medicine, Sant'Orsola-Malpighi Hospital, University of Bologna, Bologna, Italy
| | - Enrico Gallitto
- Unit of Vascular Surgery, Department of Experimental, Diagnostic and Specialty Medicine, Sant'Orsola-Malpighi Hospital, University of Bologna, Bologna, Italy -
| | - Rodolfo Pini
- Unit of Vascular Surgery, Department of Experimental, Diagnostic and Specialty Medicine, Sant'Orsola-Malpighi Hospital, University of Bologna, Bologna, Italy
| | - Jacopo Giordano
- Unit of Vascular Surgery, Department of Experimental, Diagnostic and Specialty Medicine, Sant'Orsola-Malpighi Hospital, University of Bologna, Bologna, Italy
| | - Chiara Mascoli
- Unit of Vascular Surgery, Department of Experimental, Diagnostic and Specialty Medicine, Sant'Orsola-Malpighi Hospital, University of Bologna, Bologna, Italy
| | - Alessia Sonetto
- Unit of Vascular Surgery, Department of Experimental, Diagnostic and Specialty Medicine, Sant'Orsola-Malpighi Hospital, University of Bologna, Bologna, Italy
| | - Antonino Logiacco
- Unit of Vascular Surgery, Department of Experimental, Diagnostic and Specialty Medicine, Sant'Orsola-Malpighi Hospital, University of Bologna, Bologna, Italy
| | - Stefano Ancetti
- Unit of Vascular Surgery, Department of Experimental, Diagnostic and Specialty Medicine, Sant'Orsola-Malpighi Hospital, University of Bologna, Bologna, Italy
| | - Gianluca Faggioli
- Unit of Vascular Surgery, Department of Experimental, Diagnostic and Specialty Medicine, Sant'Orsola-Malpighi Hospital, University of Bologna, Bologna, Italy
| |
Collapse
|
60
|
Intraoperative adverse events and early outcomes of custom-made fenestrated stent grafts and physician-modified stent grafts for complex aortic aneurysms. J Vasc Surg 2019; 71:1834-1842.e1. [PMID: 31708298 PMCID: PMC7126501 DOI: 10.1016/j.jvs.2019.07.102] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2019] [Accepted: 07/20/2019] [Indexed: 11/23/2022]
Abstract
OBJECTIVE Physician-modified fenestrated stent grafts (PMSGs) are a useful option for urgent or semiurgent treatment of complex abdominal aortic aneurysms (CAAAs). The aim of this study was to describe in-hospital outcomes of custom-made fenestrated stent grafts (CMSGs) and PMSGs for the treatment of CAAAs and thoracoabdominal aortic aneurysms (TAAAs). METHODS In this single-center, retrospective study, all consecutives patients with CAAAs or TAAAs undergoing endovascular repair using Zenith CMSGs (Cook Medical, Bloomington, Ind) or PMSGs between January 2012 and November 2017 were included. End points were intraoperative adverse events, in-hospital mortality, postoperative complications, reinterventions, target vessel patency, and endoleaks. RESULTS Ninety-seven patients were included (CMSGs, n = 69; PMSGs, n = 28). The PMSG group included more patients assigned to American Society of Anesthesiologists class 4 (n = 14 [50%] vs n = 16 [23%]; P = .006) and more TAAAs (n = 17 [61%] vs n = 10 [15%]; P < .0001). Intraoperative adverse events were recorded in eight (11%) patients in the CMSG group vs six (21%) patients in the PMSG group. No intraoperative death or open conversion occurred. In-hospital mortality rates were of 4% (n = 3) in the CMSG group and 14% in the PMSG group (n = 4). Chronic renal failure was an independent preoperative risk factor of postoperative death or complications (odds ratio, 4.88; 95% confidence interval, 1.65-14.43; P = .004). Rates of postoperative complications were 22% (n = 15) and 25% (n = 7) in the CMSG and PMSG groups. Spinal cord ischemia rates were 4% (n = 3) and 7% (n = 2) in the CMSG and PMSG groups. Reintervention rates were 16% (n = 11) in the CMSG group and 32% (n = 9) in the PMSG group. At discharge, target vessel patency rate in CMSGs was 98% (n = 207/210). All target vessels (n = 98) were patent in the PMSG group. Endoleaks at discharge were observed in 24% of the CMSG group (n = 16) vs 8% of the PMSG group (n = 2). CONCLUSIONS Our study showed clinically relevant differences of several important in-hospital outcomes in the CMSG and PMSG groups. Larger cohorts and longer follow-up are needed to allow direct comparison. PMSGs may offer acceptable in-hospital results in patients requiring urgent interventions when CMSGs are not available or possible.
Collapse
|
61
|
Yoon WJ. Fenestrated Endovascular Aneurysm Repair versus Snorkel Endovascular Aneurysm Repair: Competing yet Complementary Strategies. Vasc Specialist Int 2019; 35:121-128. [PMID: 31620398 PMCID: PMC6774433 DOI: 10.5758/vsi.2019.35.3.121] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2019] [Revised: 09/10/2019] [Accepted: 09/10/2019] [Indexed: 11/20/2022] Open
Abstract
Juxtarenal/pararenal aortic aneurysms and type IV thoracoabdominal aneurysms pose particular technical challenges for endovascular repair as they involve the visceral segment in addition to insufficient infrarenal neck for the use of standard endovascular aneurysm repair (EVAR) devices. To overcome these challenges, complex EVAR techniques have been developed to extend the proximal landing zone cephalad with maintaining perfusion to vital aortic branches, thereby broadening the applicability of endografting from the infrarenal to the suprarenal aorta. Complex EVAR can be divided into two broad categories: fenestrated endovascular aneurysm repair (FEVAR) and snorkel EVAR. FEVAR is a valid procedure with the standardized procedure, although it remains as a relatively complex procedure with a learning curve. Given time constraints for the custom fenestrated graft, snorkel EVAR may be an alternative for complex repairs in symptomatic or ruptured patients for whom custom-made endografts may not be immediately available. This article discusses these two most commonly used complex EVAR strategies.
Collapse
Affiliation(s)
- William J Yoon
- Division of Vascular Surgery, Department of Surgery, University of California-Davis Medical Center, Sacramento, CA, USA
| |
Collapse
|
62
|
Koenrades MA, Struijs EM, Klein A, Kuipers H, Reijnen MMPJ, Slump CH, Geelkerken RH. Quantitative Stent Graft Motion in ECG Gated CT by Image Registration and Segmentation: In Vitro Validation and Preliminary Clinical Results. Eur J Vasc Endovasc Surg 2019; 58:746-755. [PMID: 31548160 DOI: 10.1016/j.ejvs.2019.03.009] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2018] [Accepted: 03/07/2019] [Indexed: 11/16/2022]
Abstract
OBJECTIVES The dynamic endovascular environment of stent grafts may influence long term outcome after endovascular aneurysm repair (EVAR). The sealing and fixation of a stent graft to the aortic wall is challenged at every heartbeat, yet knowledge of the cardiac induced dynamics of stent grafts is sparse. Understanding the stent-artery interaction is crucial for device development and may aid the prediction of failure in the individual patient. The aim of this work was to establish quantitative stent graft motion in multiphasic electrocardiogram (ECG) gated computed tomography (CT) by image registration and segmentation techniques. METHODS Experimental validation was performed by evaluating a series of ECG gated CT scans of a stent graft moving at different amplitudes of displacement at different virtual heart rates using a motion generating device with synchronised ECG triggering. The methodology was further tested on clinical data of patients treated with EVAR devices with different stent graft designs. Displacement during the cardiac cycle was analysed for points on the fixating stent rings, the branches or fenestrations, and the spine. RESULTS Errors for the amplitude of displacement measured in vitro at individual points on the wire frame were at most 0.3 mm. In situ cardiac induced displacement of the devices was found to differ per location and also depended on the type of stent graft. Displacement during the cardiac cycle was greatest in a fenestrated device and smallest in a chimney graft sac anchoring endosystem, with maximum displacement varying from 0.0 to 1.4 mm. There was no substantial displacement measurable in the spine. CONCLUSIONS A novel methodology to quantify and visualise stent graft motion in multiphasic ECG gated CT has been validated in vitro and tested in vivo. This methodology enables further exploration of in situ motion of different stent grafts and branch stents and their interaction with native vessels.
Collapse
Affiliation(s)
- Maaike A Koenrades
- Multi-modality Medical Imaging (M3I) group, Faculty of Science and Technology, Technical Medical Centre, University of Twente, Enschede, the Netherlands; Department of Vascular Surgery, Medisch Spectrum Twente, Enschede, the Netherlands; Robotics and Mechatronics (RaM) group, Faculty of Electrical Engineering, Mathematics and Computer Science, Technical Medical Centre, University of Twente, Enschede, the Netherlands.
| | - Esmeralda M Struijs
- Technical Medicine, Faculty of Science and Technology, Technical Medical Centre, University of Twente, Enschede, the Netherlands
| | - Almar Klein
- Independent Scholar, Enschede, the Netherlands
| | - Hendrik Kuipers
- Robotics and Mechatronics (RaM) group, Faculty of Electrical Engineering, Mathematics and Computer Science, Technical Medical Centre, University of Twente, Enschede, the Netherlands
| | - Michel M P J Reijnen
- Multi-modality Medical Imaging (M3I) group, Faculty of Science and Technology, Technical Medical Centre, University of Twente, Enschede, the Netherlands; Department of Vascular Surgery, Rijnstate, Arnhem, the Netherlands
| | - Cornelis H Slump
- Robotics and Mechatronics (RaM) group, Faculty of Electrical Engineering, Mathematics and Computer Science, Technical Medical Centre, University of Twente, Enschede, the Netherlands
| | - Robert H Geelkerken
- Multi-modality Medical Imaging (M3I) group, Faculty of Science and Technology, Technical Medical Centre, University of Twente, Enschede, the Netherlands; Department of Vascular Surgery, Medisch Spectrum Twente, Enschede, the Netherlands
| |
Collapse
|
63
|
Endovascular Treatment of Complex Aneurysms with the Use of Covera Stent Grafts. J Vasc Interv Radiol 2019; 30:1942-1948.e1. [PMID: 31530494 DOI: 10.1016/j.jvir.2019.05.004] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2019] [Revised: 05/01/2019] [Accepted: 05/02/2019] [Indexed: 11/21/2022] Open
Abstract
PURPOSE To characterize the short-term results of a newly available self-expanding covered stent (Covera; CR Bard Peripheral Vascular Inc., Murray Hill, New Jersey) for the reconstruction of target vessels in complex aneurysms. MATERIALS AND METHODS From August 2017 to November 2018, this self-expanding covered stent was used in 17 patients (mean 72.6 ± 7.6 years of age) during endovascular aneurysm repair (EVAR) with hypogastric preservation (11.8%), branched EVAR (29.4%), fenestrated (F)-EVAR (17.6%), chimney + F-EVAR (11.8%), or chimney EVAR (29.4%). In more than 48 stented arteries (2.8 ± 1.1/patient), 25 were preserved using this self-expanding covered stent. RESULTS All target vessels were successfully preserved. There was no 30-day mortality and 1 in-hospital death. Intraoperative aneurysm exclusion was successful in 14 patients (82.4%) with a perioperative technical success rate of 82.4%. The actuarial survival rate was 93.8% at 6 months and 85.9% at 12 months. Aneurysm sac regression of >5 mm was observed in 4 cases (23.5%), and the sac remained stable in the remaining patients (13 cases [76.5%]). At 12 months, the primary clinical success rate was 76.5%, and assisted primary clinical success rate was 82.4%. No type 3 endoleak was related to a disruption of the reconstruction with the self-expanding covered stent. CONCLUSIONS This new self-expanding covered stent provides good short-term patency in chimneys, branches, or fenestrations. Larger series with long-term follow-up are required to determine if the stent can sustain the mechanical stress to which it will be submitted in these repairs.
Collapse
|
64
|
Chimney Stent Graft Technique for Endovascular Repair of Penetrating Atherosclerotic Ulcers of Abdominal Aorta with Bilateral Common Iliac Artery Aneurysms and Ectopic Right Renal Artery Stenosis. Ann Vasc Surg 2019; 62:499.e9-499.e14. [PMID: 31536789 DOI: 10.1016/j.avsg.2019.06.046] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2019] [Revised: 06/01/2019] [Accepted: 06/29/2019] [Indexed: 11/20/2022]
Abstract
Ectopic renal artery (RA), a rare congenital anomaly, presents a challenge in open surgery and endovascular repair for abdominal aortic lesions. To preserve the abnormal main blood supply and renal function complicates the procedures requiring careful imaging measurement and well-designed therapeutic strategy. We report on a 68-year-old man with abdominal aortic atherosclerotic ulcers, bilateral common iliac artery aneurysms, and right ectopic RA stenosis that was successfully managed with antegrade chimney technique, resulting in well-excluded lesions and well-reconstructed renal blood supply without any complication. This endovascular procedure may be useful for repair of abdominal aortic lesions with ectopic RA in high-risk surgical patients.
Collapse
|
65
|
Motta F, Crowner JR, Kalbaugh CA, Knowles M, Pascarella L, McGinigle KL, Farber MA. Stenting of superior mesenteric and celiac arteries does not increase complication rates after fenestrated-branched endovascular aneurysm repair. J Vasc Surg 2019; 70:691-701. [DOI: 10.1016/j.jvs.2018.11.043] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2018] [Accepted: 11/13/2018] [Indexed: 11/17/2022]
|
66
|
Endosuture aneurysm repair in patients treated with Endurant II/IIs in conjunction with Heli-FX EndoAnchor implants for short-neck abdominal aortic aneurysm. J Vasc Surg 2019; 70:732-740. [DOI: 10.1016/j.jvs.2018.11.033] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2018] [Accepted: 11/07/2018] [Indexed: 11/19/2022]
|
67
|
Giles KA, Scali ST, Pearce BJ, Huber TS, Berceli SA, Arnaoutakis DJ, Back MR, Fatima J, Upchurch GR, Beck AW. Impact of secondary interventions on mortality after fenestrated branched endovascular aortic aneurysm repair. J Vasc Surg 2019; 70:1737-1746.e1. [PMID: 31420254 DOI: 10.1016/j.jvs.2019.02.029] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2018] [Accepted: 02/09/2019] [Indexed: 11/30/2022]
Abstract
BACKGROUND Fenestrated and branched endovascular aortic repair (F/BEVAR) is increasingly used to manage pararenal and thoracoabdominal aortic disease (TAAA). Device-related reintervention after F/BEVAR is common, but little is known about its impact on postoperative mortality. The purpose of this analysis was to describe secondary intervention (SI) after F/BEVAR and determine the impact of these procedures on patient survival. METHODS A single-center review was done on all consecutive F/BEVARs performed from 2010 to 2016. Primary end points were incidence of secondary aortic, branch, and/or access vessel‒related SI, and survival. SI was categorized as minor endovascular (branch restenting, access vessel treatment, or percutaneous coil embolization), major endovascular (new aortic graft placement), or open (bleeding, access vessel, and/or aortic). Kaplan-Meier methodology was used to estimate freedom from SI and survival. Multivariable analysis was used to identify predictors of SI. RESULTS A total of 308 F/BEVAR procedures were performed (75% physician-modified, 18% custom, 7% Zfen), with 1022 vessels revascularized (celiac, 228; superior mesenteric artery [SMA], 263; renal, 525). There were 117 (39%) extent I-III TAAA, 132 (44%) extent IV TAAA/4-vessel pararenal, and 54 (18%) <4-vessel pararenal repairs performed. Any type of SI occurred in 24% (74) of patients during the mean follow-up of 20 ± 21 months. The majority of reinterventions were endovascular (minor, 53% [n = 39]; major, 32% [n = 24]), whereas 12% (n = 9) were open and 3% (n = 2) hybrid. Primary indication for SI included: 22 (29%) with branch-related endoleaks (1C or III); 15 (22%) with proximal or distal aortic degeneration; 8 (12%) with branch vessel thrombosis/stenosis; 10 (11%) with aortic device type III endoleak/loss of overlap; 4 (6%) with postoperative mesenteric or renal bleeding events; 5 (5%) with type II endoleak; 3 (5%) with access vessel complication; and 2 (3%) with graft infection. Most SIs were elective (65%; n = 48) with the remainder occurring emergently (24%; n = 18) or for symptoms/urgently (11%; n = 8). Compared with endovascular remediation, open SI was more likely to be emergent (89%, 8 of 9; P = .001). Freedom from SI was 80 ± 3% and 64 ± 4% at 1 and 3 years, respectively. One- and 5-year survival with or without SI was: 1 year, 88 ± 4% vs 81 ± 3%; 5 years, 76 ± 5% vs 59 ± 4% (log rank test, P = .06). There was no survival difference based on type of SI (log rank test, P = .3). Extent I-III TAAA (HR, 1.6; 95% CI, 0.98-3.3; P = .06) and history of cerebrovascular disease (HR, 1.8; 95% CI, 0.97-2.6; P = .07) were predictive of SI. CONCLUSIONS SIs after F/BEVAR most frequently involve branch vessel or aortic device remediation procedures; however, they do not negatively impact out-of-hospital survival. These results further highlight the crucial role of imaging surveillance after F/BEVAR to maintain durability. Discussions with patients, periprocedural planning, and the next generation of device design must focus on issues surrounding the risk of device-related SI events.
Collapse
Affiliation(s)
- Kristina A Giles
- Division of Vascular Surgery and Endovascular Therapy, University of Florida, Gainesville, Fla.
| | - Salvatore T Scali
- Division of Vascular Surgery and Endovascular Therapy, University of Florida, Gainesville, Fla
| | - Benjamin J Pearce
- Division of Vascular Surgery and Endovascular Therapy, University of Alabama at Birmingham, Birmingham, Ala
| | - Thomas S Huber
- Division of Vascular Surgery and Endovascular Therapy, University of Florida, Gainesville, Fla
| | - Scott A Berceli
- Division of Vascular Surgery and Endovascular Therapy, University of Florida, Gainesville, Fla
| | - Dean J Arnaoutakis
- Division of Vascular Surgery and Endovascular Therapy, University of Florida, Gainesville, Fla
| | - Martin R Back
- Division of Vascular Surgery and Endovascular Therapy, University of Florida, Gainesville, Fla
| | - Javairiah Fatima
- Division of Vascular Surgery and Endovascular Therapy, University of Florida, Gainesville, Fla
| | - Gilbert R Upchurch
- Division of Vascular Surgery and Endovascular Therapy, University of Florida, Gainesville, Fla
| | - Adam W Beck
- Division of Vascular Surgery and Endovascular Therapy, University of Alabama at Birmingham, Birmingham, Ala
| |
Collapse
|
68
|
Hurd JR, Tatum B, Grillo J, Arthurs Z, Singh N, Fong H, Sarikaya M, Allen-Kline B, Starnes BW. Long-term durability of a physician-modified endovascular graft. J Vasc Surg 2019; 71:628-634. [PMID: 31401117 DOI: 10.1016/j.jvs.2019.04.471] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2018] [Accepted: 04/28/2019] [Indexed: 10/26/2022]
Abstract
We present a unique assessment confirming the long-term durability of a physician-modified endograft deployed as part of an Investigational Device Exemption clinical trial (NCT# 01538056). After receiving an intact postmortem aorta 7 years after the index procedure, we performed microcomputed tomography, necropsy, and metallurgical analysis on the specimen. Microcomputed tomography showed a single strut fracture not noted during previous surveillance. Necropsy revealed no graft fabric compromise, and examination of all three visceral fenestrations showed excellent alignment with no evidence of degradation. Analysis of the strut fracture implicated an initially small, fatigue-induced crack that likely succumbed during postmortem handling.
Collapse
Affiliation(s)
- Jason R Hurd
- Division of Vascular Surgery, University of Washington, Seattle, Wash
| | - Billi Tatum
- Division of Vascular Surgery, University of Washington, Seattle, Wash
| | - Jenna Grillo
- Autopsy and Pathology Lab, University of Washington, Seattle, Wash
| | | | - Niten Singh
- Division of Vascular Surgery, University of Washington, Seattle, Wash
| | - Hanson Fong
- Genetically Engineered Materials Science and Engineering Center, University of Washington, Seattle, Wash
| | - Mehmet Sarikaya
- Genetically Engineered Materials Science and Engineering Center, University of Washington, Seattle, Wash
| | | | | |
Collapse
|
69
|
Zacharias N, Wang GJ, Sedrakyan A, Columbo JA, Boyle JR, Goodney PP. Using the Idea, Development, Exploration, Assessment, Long-Term Study Framework for Devices (IDEAL-D) to Better Understand the Evolution of Evidence Surrounding Fenestrated Abdominal Aortic Endovascular Grafts. Ann Vasc Surg 2019; 59:293-299. [PMID: 31009709 PMCID: PMC10767621 DOI: 10.1016/j.avsg.2019.02.010] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2018] [Revised: 02/06/2019] [Accepted: 02/10/2019] [Indexed: 12/20/2022]
Abstract
The use of fenestrated endovascular devices for repair of complex aortic aneurysms has increased to nearly 5,000 implantations annually among Medicare patients in the United States in recent years. Given that nearly all aspects of treatment for minimally invasive aortic intervention rely on medical devices to better care for patients with vascular disease, clearly understanding how new and innovative technology evolves over the life cycle of a medical device is an essential skill set for cardiovascular physicians. Despite the need for this understanding, there is no standard framework upon which cardiovascular physicians, regulators, and patients can rely on to better understand the evolution of evidence from product inception through adoption and long-term effectiveness evaluation. As the aforementioned devices are increasingly and broadly used, the need for a formal framework for regulation and device approval has emerged. The goal of this review is to describe the Idea, Development, Exploration, Assessment, Long-term Study Framework for Devices (IDEAL-D). This framework is a model developed recently by an international panel of experts dedicated to better understanding the data steps necessary to bring a device from idea to routine practice and further to marketing, approval, and monitoring. In this review, we use the example of fenestrated endovascular aortic devices to illustrate the IDEAL-D framework, how it can help cardiovascular physicians improve their understanding of new technology, and the evidence which surrounds it from inception to long-term use.
Collapse
Affiliation(s)
- Nikolaos Zacharias
- Section of Vascular Surgery, Dartmouth-Hitchcock Medical Center, Lebanon, NH
| | - Grace J Wang
- Division of Vascular Surgery, Hospital of the University of Pennsylvania, Philadelphia, PA
| | - Art Sedrakyan
- Department of Surgery, Weill Cornell Medical College, New York, NY
| | - Jesse A Columbo
- Section of Vascular Surgery, Dartmouth-Hitchcock Medical Center, Lebanon, NH; The Dartmouth Institute for Health Policy and Clinical Practice, Lebanon, NH
| | - Jonathan R Boyle
- Cambridge University Hospitals NHS Trust, Addenbrookes Hospital, Cambridge, UK
| | - Philip P Goodney
- Section of Vascular Surgery, Dartmouth-Hitchcock Medical Center, Lebanon, NH; The Dartmouth Institute for Health Policy and Clinical Practice, Lebanon, NH.
| |
Collapse
|
70
|
Image Fusion Guidance for In Situ Laser Fenestration of Aortic Stent graft for Endovascular Repair of Complex Aortic Aneurysm: Feasibility, Efficacy and Overall Functional Success. Cardiovasc Intervent Radiol 2019; 42:1371-1379. [DOI: 10.1007/s00270-019-02231-8] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/11/2019] [Accepted: 04/19/2019] [Indexed: 01/29/2023]
|
71
|
Van Calster K, Bianchini A, Elias F, Hertault A, Azzaoui R, Fabre D, Sobocinski J, Haulon S. Risk factors for early and late mortality after fenestrated and branched endovascular repair of complex aneurysms. J Vasc Surg 2019; 69:1342-1355. [DOI: 10.1016/j.jvs.2018.08.159] [Citation(s) in RCA: 31] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2018] [Accepted: 08/17/2018] [Indexed: 11/27/2022]
|
72
|
Reyes Valdivia A, Beropoulis E, Pitoulias G, Pratesi G, Alvarez Marcos F, Barbante M, Gandarias C, Torsello G, Bisdas T, Donas K. Multicenter Registry about the Use of EndoAnchors in the Endovascular Repair of Abdominal Aortic Aneurysms with Hostile Neck Showed Successful but Delayed Endograft Sealing within Intraoperative Type Ia Endoleak Cases. Ann Vasc Surg 2019; 60:61-69. [PMID: 31028850 DOI: 10.1016/j.avsg.2019.01.017] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2018] [Revised: 01/08/2019] [Accepted: 01/17/2019] [Indexed: 10/27/2022]
Abstract
BACKGROUND The durability of endovascular aortic aneurysms repair (EVAR) is highly related to several anatomical constraints. The term "hostile neck" describes several anatomical features that usually make EVAR treatment technically demanding despite having higher risk of failure. The aim of the study was to describe a multicenter experience with EVAR and an adjunctive use of EndoAnchors in hostile neck anatomies. METHODS Data were prospectively collected from 4 academic vascular centers including 46 patients with a hostile neck treated by standard EVAR with the adjunctive use of EndoAnchors. Twenty-two of them (47.8%, group A) had an intraoperative type Ia endoleak, and 24 (52.2%) patients were treated in a preventive manner (group B). Primary endpoints were technical and procedural success. Secondary endpoints were regression of the aneurysm sac, freedom from type Ia endoleak, and reinterventions. RESULTS Neck length and diameter showed no statistical difference in preoperative measures, 9.1 ± 6.9 mm and 8.6 ± 2.8 mm and 25.4 ± 4.7 mm and 27.3 ± 4.7 mm, in group A and B, respectively. Aneurysm sac diameter decreased from 58.2 ± 8 mm and 57.9 ± 9.8 mm to 55.7 ± 8.5 mm and 53.8 ± 10.4 mm in group A and B; respectively, at the last computed tomography scan. Technical and procedural success was 97.8% and 100%, respectively, for group B. Group A showed persistence of type Ia endoleak at completion angiogram in 9 (40.9%) patients. Five of them showed early spontaneous sealing at the first (30 days) computed tomography angiography (CTA), and in the remaining 4, a delayed spontaneous sealing was diagnosed at 12-month CTA. No neck-related secondary procedures were performed. Overall survival was 91%. CONCLUSIONS Our study shows that additional use of EndoAnchors can successfully improve the sealing of abdominal endografts in case of intraoperative type Ia endoleaks in hostile neck anatomies, representing a safe and effective endovascular alternative in our armamentarium. However, meticulous radiological follow-up is necessary because complete resolution of all observed intraoperative type Ia endoleaks was not observed until the 12-month CTA follow-up.
Collapse
Affiliation(s)
- Andrés Reyes Valdivia
- Department of Vascular and Endovascular Surgery, Ramón y Cajalś University Hospital, Madrid, Spain.
| | - Efthymios Beropoulis
- Department of Vascular Surgery, St Franziskus Hospital Münster, Clinic for Vascular and Endovascular Surgery, Münster University Hospital, Münster, Germany
| | - Georgios Pitoulias
- Department of Surgery, Gennimatas Hospital, Aristotle University of Thessaloniki, Thessaloniki, Greece
| | - Giovanni Pratesi
- Vascular Surgery Unit, Department of Biomedicine and Prevention, University of Rome Tor Vergata, Rome, Italy
| | - Francisco Alvarez Marcos
- Department of Vascular and Endovascular Surgery, Juan Canalejo's University Hospital, A Coruña, Spain
| | - Matteo Barbante
- Vascular Surgery Unit, Department of Biomedicine and Prevention, University of Rome Tor Vergata, Rome, Italy
| | - Claudio Gandarias
- Department of Vascular and Endovascular Surgery, Ramón y Cajalś University Hospital, Madrid, Spain
| | - Giovanni Torsello
- Department of Vascular Surgery, St Franziskus Hospital Münster, Clinic for Vascular and Endovascular Surgery, Münster University Hospital, Münster, Germany
| | - Theodosios Bisdas
- Department of Vascular Surgery, St Franziskus Hospital Münster, Clinic for Vascular and Endovascular Surgery, Münster University Hospital, Münster, Germany
| | - Konstantinos Donas
- Department of Vascular Surgery, St Franziskus Hospital Münster, Clinic for Vascular and Endovascular Surgery, Münster University Hospital, Münster, Germany
| |
Collapse
|
73
|
Jin X, Xu S, Chen Z, Zhang X, Huang L, Sun L. A Study on the Pressure-Lowering Effect of the Multilayer Stent. Ann Vasc Surg 2019; 59:237-243. [PMID: 31009729 DOI: 10.1016/j.avsg.2019.01.012] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2018] [Accepted: 01/22/2019] [Indexed: 11/18/2022]
Abstract
BACKGROUND The objective of the study was to investigate the hemodynamic changes of the blood flow in the aneurysm model after the multilayer stent placement using the fluid dynamic method, to analyze the effectiveness and properties of the multilayer stent in the treatment of aortic aneurysms. METHODS A water tank was filled with 5 L of experimental liquid after the circular flow pressure test platform with a glass aneurysm model, and a multilayer stent was built. Pressure at the middle part and the distal aneurysm neck part of the model was then measured. At each site, the pressure was measured 20 times at 1-min intervals, and the testing results were averaged for accuracy. RESULTS Without the stent, mean pressure at the middle part and at the distal aneurysm neck part of the model was 11.19 ± 0.23 Kpa and 13.31 ± 0.28 Kpa, respectively. With the stent, the mean pressure decreased to 10.60 ± 0.27 Kpa and 12.60 ± 0.29 Kpa, and the average difference was 0.59 ± 0.15 Kpa and 0.71 ± 0.15 Kpa, respectively. CONCLUSIONS After the placement of the multilayer stent, pressure inside the model at the middle part and distal neck part could both be diminished, yet the mean dropped pressure may be too small to be sufficient to cause significant impact on preventing the expansion of abdominal aortic aneurysm; therefore, the pressure-lowering effect of the multilayer stent for abdominal aortic aneurysm may not be ideal compared with the traditional covered stents.
Collapse
Affiliation(s)
- Xiufeng Jin
- Department of Cardiology Ward 1, Beijing Anzhen Hospital of Capital Medical University, Beijing, China
| | - Shangdong Xu
- Department of Cardiology Ward 1, Beijing Anzhen Hospital of Capital Medical University, Beijing, China
| | - Zengsheng Chen
- School of Aerospace Engineering, Tsinghua University, Beijing, China
| | - Xiwen Zhang
- School of Aerospace Engineering, Tsinghua University, Beijing, China
| | - Lianjun Huang
- Department of Interference Diagnosis & Treatment, Beijing Anzhen Hospital of Capital Medical University, Beijing, China
| | - Lizhong Sun
- Department of Cardiology Ward 1, Beijing Anzhen Hospital of Capital Medical University, Beijing, China.
| |
Collapse
|
74
|
Outcomes of Open Repair, Fenestrated Stent Grafting, and Chimney Grafting in Juxtarenal Abdominal Aortic Aneurysm: Is It Time for a Randomized Trial? Ann Vasc Surg 2019; 56:114-123. [DOI: 10.1016/j.avsg.2018.08.097] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2018] [Revised: 08/17/2018] [Accepted: 08/27/2018] [Indexed: 11/18/2022]
|
75
|
Stackelberg O, Lindström D, Mani K, Lundberg G, Linné A, Delle M, Berger M, Wanhainen A, Gillgren P. Outcomes after endovascular repair of abdominal aortic aneurysm involving the renovisceral arteries: A multi-center follow-up study. Vascular 2019; 27:397-404. [PMID: 30871441 DOI: 10.1177/1708538119836016] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Objectives To evaluate outcomes after endovascular treatment of abdominal aortic aneurysms (AAA) involving the renovisceral arteries and to compare outcomes after fenestrated/branched endovascular aortic repair (f/b-EVAR), chimney/periscope EVAR (ch-EVAR), and bailout ch-EVAR. Methods A retrospective multicenter study including all patients with AAA involving the renovisceral segment, treated with f/b-EVAR, ch-EVAR, or bailout ch-EVAR, between 1 January 2005 and 30 June 2015, in three Swedish vascular centers. Patient charts were reviewed for data. Renovisceral stent graft patency was assessed on follow-up CT. Mortality was cross-checked against the Swedish Population Registry. Bailout ch-EVAR was defined as a perioperative decision of renovisceral endografting, as the artery was accidentally covered, or as the aneurysm neck sealing zone was considered inadequate. Results Of the 99 identified patients (76 men; mean age 74 years (range 58–89 years)), 68 underwent f/b-EVAR, 18 ch-EVAR, and 13 bailout ch-EVAR. Follow-up lasted for a median of 3.2 years (Q1, Q3 (2.1, 4.7 years)). Elective surgery comprised 87.9% ( n = 87) of the cases. Six patients died within 30 days, and the 30-day mortality after elective surgery was 4.6% (95% CI, 1.3%–11.4%) overall, 1.6% after f/b-EVAR (95% CI, 0.0%–11.4%), 15.4% after ch-EVAR (95% CI, 1.9%–45.4%), and 10.0% (95% CI, 0.3%–44.5%) after bailout ch-EVAR. During follow-up, there were 16 secondary interventions, of which 75% ( n = 12) were performed within six months after the primary intervention. Compared with f/b-EVAR, ch-EVAR was associated with a higher degree of type 1 endoleaks (1.5% vs. 22.2%, P = 0.001) and re-interventions during follow-up (13.2% vs. 33.3%, P = 0.046). The overall assisted target vessel patency was 96.1% (95% CI, 91.7%–98.6%) at one year and 95.2% (95% CI, 89.2%–98.4%) at two years. Conclusions Results after EVAR involving endografting of renovisceral arteries from three centers in Sweden with medium volumes are consistent with results previously reported from centers with larger volumes.
Collapse
Affiliation(s)
- Otto Stackelberg
- 1 Section of Vascular Surgery, Department of Clinical Science and Education, Karolinska Institutet at Södersjukhuset, Stockholm, Sweden.,2 Unit of Nutritional Epidemiology, Institute of Environmental Medicine, Karolinska Institutet, Stockholm, Sweden
| | - David Lindström
- 3 Department of Vascular Surgery, MMK, Karolinska Institutet, Karolinska University Hospital, Solna, Sweden
| | - Kevin Mani
- 4 Department of Surgical Sciences, Vascular Surgery, Uppsala University, Uppsala, Sweden
| | - Göran Lundberg
- 3 Department of Vascular Surgery, MMK, Karolinska Institutet, Karolinska University Hospital, Solna, Sweden
| | - Anneli Linné
- 1 Section of Vascular Surgery, Department of Clinical Science and Education, Karolinska Institutet at Södersjukhuset, Stockholm, Sweden
| | - Martin Delle
- 5 Department of Radiology, Karolinska Institutet, Karolinska University Hospital, Huddinge, Sweden
| | - Martin Berger
- 6 Department of Radiology, Department of Clinical Science and Education, Karolinska Institutet, Södersjukhuset, Stockholm, Sweden
| | - Anders Wanhainen
- 4 Department of Surgical Sciences, Vascular Surgery, Uppsala University, Uppsala, Sweden
| | - Peter Gillgren
- 1 Section of Vascular Surgery, Department of Clinical Science and Education, Karolinska Institutet at Södersjukhuset, Stockholm, Sweden
| |
Collapse
|
76
|
Affiliation(s)
- Nicholas J. Swerdlow
- From the Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA
| | - Winona W. Wu
- From the Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA
| | - Marc L. Schermerhorn
- From the Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA
| |
Collapse
|
77
|
Marques de Marino P, Malgor RD, Verhoeven EL, Katsargyris A. Rescue of proximal failure of endovascular abdominal aortic aneurysm repair with standard and fenestrated grafts. THE JOURNAL OF CARDIOVASCULAR SURGERY 2019; 60:159-166. [PMID: 30665286 DOI: 10.23736/s0021-9509.19.10872-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
BACKGROUND This study aimed to assess the outcomes of standard and fenestrated grafts to treat proximal failure of previous endovascular aneurysm repair (EVAR) in a tertiary referral center. METHODS All patients undergoing elective implantation of a standard or fenestrated graft after proximal failure of a previous EVAR between April 2010-November 2018 were included. Data were collected prospectively. RESULTS Fifty procedures were performed in 49 patients (45 male; mean age 74.6±7 years). A fenestrated proximal cuff was used in 24 (48%) cases, a composite bifurcated configuration in 21 (42%) cases, and EVAR in 5 (10%) cases. Technical success was achieved in all 5 EVAR cases and 41 of 45 FEVAR cases (91.1%). Iliac artery access problems due to the presence of the previous graft were encountered in eight (16%) procedures and renal artery catheterization difficulties in grafts with suprarenal fixation in seven (15.6%) procedures. There was one (2%) early death due to retroperitoneal bleeding. Early major complications occurred in three (6%) patients. Median follow-up was 26 months (range 1-77). Late occlusion occurred in two (1.3%) of the 151 targeted vessels. One patient needed permanent dialysis. Nine patients died during follow-up, one (2%) of them aneurysm-related. Ten (20.4%) patients presented with major complications during follow-up of which nine (18.4%) needed reintervention. Estimated freedom from reintervention at 1 and 3 years was 89.3±5.1% and 78.8±7.3%, respectively. CONCLUSIONS Repair with fenestrated grafts represents a safe and effective treatment option. Increased technical challenges are to be expected due to the previous graft.
Collapse
Affiliation(s)
- Pablo Marques de Marino
- Department of Vascular and Endovascular Surgery, General Hospital Nuremberg, Paracelsus Medical University Nuremberg, Nuremberg, Germany
| | - Rafael D Malgor
- Department of Vascular and Endovascular Surgery, General Hospital Nuremberg, Paracelsus Medical University Nuremberg, Nuremberg, Germany
| | - Eric L Verhoeven
- Department of Vascular and Endovascular Surgery, General Hospital Nuremberg, Paracelsus Medical University Nuremberg, Nuremberg, Germany
| | - Athanasios Katsargyris
- Department of Vascular and Endovascular Surgery, General Hospital Nuremberg, Paracelsus Medical University Nuremberg, Nuremberg, Germany -
| |
Collapse
|
78
|
Fiorucci B, Speziale F, Kölbel T, Tsilimparis N, Sirignano P, Capoccia L, Simonte G, Verzini F. Short- and Midterm Outcomes of Open Repair and Fenestrated Endografting of Pararenal Aortic Aneurysms in a Concurrent Propensity-Adjusted Comparison. J Endovasc Ther 2018; 26:105-112. [DOI: 10.1177/1526602818820090] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Purpose: To compare outcomes of patients treated for pararenal aortic aneurysms using fenestrated endovascular aneurysm repair (fEVAR) vs open surgical repair (OSR) in 3 high-volume centers. Materials and Methods: A multicenter retrospective analysis was conducted of 200 pararenal abdominal aortic aneurysm patients electively treated with OSR (n=108) or fEVAR (n=92) from 1998 to 2015 at 3 tertiary institutions. Endpoints were 30-day morbidity and mortality, late reinterventions, visceral artery occlusion, and mortality. Analysis was conducted on the entire population and on a propensity score–matched population constructed on age, gender, coronary artery disease (CAD), and chronic renal failure. Results: In the total cohort, fEVAR patients were significantly (p<0.001) older and had higher frequencies of CAD (p<0.001) and previous stroke (p=0.003). OSR patients had higher risk of perioperative morbidity (OR 2.5, 95% CI 1.09 to 5.71, p=0.033), specifically respiratory failure (OR 4.06, 95% CI 1.12 to 4.72, p=0.034). These findings were confirmed in the propensity-adjusted analysis, where cardiac complications were also higher after OSR (OR 12.8, 95% CI 0.07 to 0.21, p=0.02). No difference in perioperative mortality (2.2% in fEVAR vs 1.9% in OSR) was identified. Mean follow-up was 50 months (range 0–119). Four-year results showed higher survival (91.2% vs 69.3%, p=0.02) and freedom from reintervention (95.6% vs 77.8%, p=0.01) after OSR in the unmatched population, with a small but significant (p=0.021) difference in the risk of late visceral artery occlusion/stenosis after fEVAR. On propensity analysis, no differences in late survival were found between groups. Conclusion: fEVAR and OSR may afford similar early and midterm survival rates. Higher risks of perioperative systemic complications after OSR are counterbalanced by higher risks of late visceral vessel patency issues and need for reintervention after fEVAR. Both procedures are safe and effective in the long term in experienced centers, where patient evaluation should drive the treatment strategy.
Collapse
Affiliation(s)
- Beatrice Fiorucci
- Unit of Vascular Surgery, Ospedale S. Maria della Misericordia, University of Perugia, Italy
- Department of Vascular Medicine, German Aortic Center, Hamburg, Germany
- Department of Vascular and Endovascular Surgery, Hospital of the Ludwig Maximilian University of Munich, Germany
| | | | - Tilo Kölbel
- Department of Vascular Medicine, German Aortic Center, Hamburg, Germany
| | - Nikolaos Tsilimparis
- Department of Vascular Medicine, German Aortic Center, Hamburg, Germany
- Department of Vascular and Endovascular Surgery, Hospital of the Ludwig Maximilian University of Munich, Germany
| | | | - Laura Capoccia
- Umberto I Hospital, “Sapienza” University of Rome, Italy
| | - Gioele Simonte
- Unit of Vascular Surgery, Ospedale S. Maria della Misericordia, University of Perugia, Italy
| | - Fabio Verzini
- Unit of Vascular Surgery, Ospedale S. Maria della Misericordia, University of Perugia, Italy
| |
Collapse
|
79
|
Goudeketting SR, Wille J, van den Heuvel DAF, Vos JA, de Vries JPPM. Midterm Single-Center Results of Endovascular Aneurysm Repair With Additional EndoAnchors. J Endovasc Ther 2018; 26:90-100. [PMID: 30514134 DOI: 10.1177/1526602818816099] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
PURPOSE To review midterm clinical outcomes of EndoAnchor placement during or after endovascular aneurysm repair (EVAR) or chimney EVAR (ch-EVAR). MATERIALS AND METHODS A retrospective analysis was conducted of 51 consecutive patients [median age 75 years; 38 men] who underwent EVAR/ch-EVAR with EndoAnchor placement between June 2010 and December 2016 to prevent seal failures (31, 61%) or to treat type Ia endoleak and/or migration (20, 39%). Median aortic neck diameter was 27.7 mm and median neck length was 9.0 mm. Thirty-three (65%) had a conical neck; 48 (94%) had at least 1 hostile neck characteristic. Thirty-two (63%) patients had severe comorbidities (ASA score ⩾III). Eight patients had a single ch-EVAR procedure. Baseline patient characteristics, anatomic variables, procedure details, early and late complications, reinterventions, and aneurysm-related and all-cause mortality rates were recorded. Follow-up imaging was performed with computed tomography angiography (CTA) or duplex ultrasonography. RESULTS Median procedure time was 100 minutes; a median of 6 EndoAnchors were implanted. There were 10 (10%) residual type Ia endoleaks at the end of the procedure; 9 had resolved by the first postoperative CTA. One residual and 2 new type Ia endoleaks were identified at the first postoperative imaging. Median follow-up for the entire cohort was 24.0 months, during which 3 new type Ia endoleaks were identified. Five of the 6 type Ia endoleaks were treated, 1 resolved spontaneously. There was 1 endograft limb occlusion without clinical consequences, 1 chimney graft occlusion without possibilities for a reintervention, 1 rupture after type IV endoleak (a Nellix device was successfully deployed within the main device), and 1 complete graft explantation for infection. There was no new-onset hemodialysis. Kaplan-Meier estimates of freedom from type Ia endoleak, proximal neck-related reinterventions, and aneurysm-related mortality at 2 years were 87.3%, 92.2%, and 94.0%, respectively. CONCLUSION EndoAnchors are helpful in the endovascular treatment of unfavorable proximal aortic necks, with fair midterm results.
Collapse
Affiliation(s)
- Seline R Goudeketting
- 1 Department of Vascular Surgery, St Antonius Hospital, Nieuwegein, the Netherlands.,2 MIRA Institute of Biomedical Technology and Technical Medicine, University of Twente, Enschede, the Netherlands
| | - Jan Wille
- 1 Department of Vascular Surgery, St Antonius Hospital, Nieuwegein, the Netherlands
| | | | - Jan-Albert Vos
- 3 Department of Interventional Radiology, St Antonius Hospital, Nieuwegein, the Netherlands
| | | |
Collapse
|
80
|
Tenorio ER, Mirza AK, Kärkkäinen JM, Oderich GS. Lessons learned and learning curve of fenestrated and branched endografts. THE JOURNAL OF CARDIOVASCULAR SURGERY 2018; 60:23-34. [PMID: 30221895 DOI: 10.23736/s0021-9509.18.10728-2] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Fenestrated and branched endovascular repair (F-BEVAR) has been increasingly used to treat patients with complex aortic aneurysms involving the renal-mesenteric arteries. As with any new procedure, there is a learning curve associated with mastering the technique. However, proficiency with deployment is only one aspect of the learning process, and ultimately, this curve is defined not by one quality parameter, but by patient selection, the performance of the entire team, the surgeon's ability to adapt to unexpected events, and the durability of the repair. This article reviews the importance of novel training paradigms, learning curve, and factors affecting outcomes of complex endovascular aneurysm repair.
Collapse
Affiliation(s)
- Emanuel R Tenorio
- Division of Vascular and Endovascular Surgery, Mayo Clinic Aortic Center, Rochester, MN, USA
| | - Aleem K Mirza
- Division of Vascular and Endovascular Surgery, Mayo Clinic Aortic Center, Rochester, MN, USA
| | - Jussi M Kärkkäinen
- Division of Vascular and Endovascular Surgery, Mayo Clinic Aortic Center, Rochester, MN, USA
| | - Gustavo S Oderich
- Division of Vascular and Endovascular Surgery, Mayo Clinic Aortic Center, Rochester, MN, USA -
| |
Collapse
|
81
|
Gallitto E, Faggioli G, Pini R, Mascoli C, Ancetti S, Abualhin M, Stella A, Gargiulo M. Renal Artery Orientation Influences the Renal Outcome in Endovascular Thoraco-abdominal Aortic Aneurysm Repair. Eur J Vasc Endovasc Surg 2018; 56:382-390. [DOI: 10.1016/j.ejvs.2018.06.007] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2017] [Accepted: 06/05/2018] [Indexed: 10/28/2022]
|
82
|
Motta F, Vallabhaneni R, Kalbaugh CA, Farber MA. The role of selective stenting for superior mesenteric artery scallops during fenestrated endovascular aneurysm repair. J Vasc Surg 2018; 69:47-52. [PMID: 29960791 DOI: 10.1016/j.jvs.2018.05.016] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2018] [Accepted: 05/10/2018] [Indexed: 11/18/2022]
Abstract
OBJECTIVE Stenting of small fenestrations of the Zenith fenestrated endograft (ZFEN; Cook Medical, Bloomington, Ind) is necessary during fenestrated endovascular aneurysm repair (FEVAR) of complex abdominal aortic aneurysms to avoid malalignment. However, stenting of superior mesenteric artery (SMA) scallops of ZFEN devices is optional according to the instructions for use. The objective of this study was to assess the early and midterm outcomes of selective use of stents in SMA scallops of ZFEN during FEVAR procedures. METHODS This study is a single-institution retrospective review of prospectively enrolled patients treated at the University of North Carolina at Chapel Hill between July 2010 and August 2014. Only patients with SMA scallops were included for analysis. We compared results between patients grouped as stented or unstented SMA scallops. The scallops were stented when one or more of the following criteria were present: misalignment of scallop determined by balloon testing intraoperatively; configuration consisting of an SMA scallop and a single renal fenestration or stent; and pre-existing stenosis in the vessel adjacent to the graft scallop. The study was approved by the local Institutional Review Board. Primary outcomes addressed were mortality, vessel patency, early and late complications, and reintervention rates. Baseline characteristics of the patients and procedure data were also described. RESULTS During the 48-month study period, 61 patients were treated for complex abdominal aortic aneurysms at the University of North Carolina with a mean age of 73 years, and 74.3% of patients were male. Thirty-nine of 61 patients (63.9%) had a device design with an SMA scallop and were included for analysis. Eleven of 39 patients (28%) had the SMA primarily stented and 28 (72%) were unstented. There was only one death (2.5%) during the 30-day postoperative period, with 100% technical success and branch patency. In the unstented group, there were three SMA complications during follow-up, two requiring reintervention; however, there were no associated deaths. Among the stented group, there was one branch-related complication that occurred during the procedure but no stent stenosis or occlusion during the long-term follow-up. During the mean follow-up period of 21.7 months, no SMA stent thrombosis occurred. There was no statistical difference in outcomes between groups. CONCLUSIONS Single-wide SMA scallops of ZFEN during FEVAR procedures may be selectively stented using specific criteria and rigorous follow-up, without compromising the safety and efficacy of the SMA.
Collapse
Affiliation(s)
- Fernando Motta
- Division of Vascular Surgery, Department of Surgery, School of Medicine, University of North Carolina, Chapel Hill, NC
| | - Raghuveer Vallabhaneni
- Director of Vascular Surgery, Baltimore Region, MedStar Heart and Vascular Institute, Baltimore, Md
| | - Corey A Kalbaugh
- Division of Vascular Surgery, Department of Surgery, School of Medicine, University of North Carolina, Chapel Hill, NC
| | - Mark A Farber
- Division of Vascular Surgery, Department of Surgery, School of Medicine, University of North Carolina, Chapel Hill, NC.
| |
Collapse
|
83
|
Editor's Choice – A Study of the Cost-effectiveness of Fenestrated/branched EVAR Compared with Open Surgery for Patients with Complex Aortic Aneurysms at 2 Years. Eur J Vasc Endovasc Surg 2018; 56:15-21. [DOI: 10.1016/j.ejvs.2017.12.008] [Citation(s) in RCA: 27] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2017] [Accepted: 12/05/2017] [Indexed: 11/18/2022]
|
84
|
Practice Patterns of Fenestrated Aortic Aneurysm Repair: Nationwide Comparison of Z-Fen Adoption at Academic and Community Centers Since Commercial Availability. Vasc Endovascular Surg 2018; 52:434-439. [DOI: 10.1177/1538574418776440] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Context: Over the past decade, a number of endovascular approaches have evolved to treat aortic aneurysms with anatomy that is not amenable to traditional endovascular repair, although the optimal practice and referral patterns remain in question. The Zenith fenestrated (Z-Fen) endograft (Cook Medical) represents the first commercially available fenestrated graft product in the United States. Objective: We aim to quantify practice patterns in Z-Fen use during the first 5 years of commercial availability, and we identify predictors of high and low uptake. Design, Setting, and Patients: This is a retrospective review of complete order records for Z-Fen endografts since June 2012. We performed univariate and multivariate regressions of predictors that surgeons and centers would be in the top and bottom quartiles of annual Z-Fen use. Results: Since June 15, 2012, 744 surgeons have been trained to use Z-Fen, and 4133 cases have been performed at 409 trained centers. The average annual number of cases per trained surgeon was 4.46 [95% confidence interval (CI), 3.58-5.70]; however, many surgeons performed few or no cases following training, and there was a skew toward users with low average annual volumes (25th percentile 1.23, 50th percentile 2.35, 75th percentile 4.93, and 99th percentile 33.29). Predictors of high annual use in the years following training included academic center (aOR 5.87, P = .001) and training within the first 2 years of availability (aOR 46.23, P < .001). Conclusion: While there is literature supporting the safety and efficacy of Z-Fen, adoption has been relatively slow in an era when the vast majority of vascular surgeons have advanced endovascular skills. Given the training and resources required to use fenestrated or branched aortic endovascular devices, referral patterns should be determined and training should be focused on centers with high expected volumes.
Collapse
|
85
|
Lucatelli P, Cini M, Benvenuti A, Saba L, Tommasino G, Guaccio G, Munneke G, Neri E, Ricci C. Custom-Made Endograft for Endovascular Repair of Thoraco-Abdominal Aneurysm and Type B Dissection: Single-Centre Experience. Cardiovasc Intervent Radiol 2018; 41:1174-1183. [PMID: 29725810 DOI: 10.1007/s00270-018-1975-3] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/01/2018] [Accepted: 04/23/2018] [Indexed: 02/04/2023]
Abstract
AIMS To report a series of patients treated with the Jotec custom-made endograft for thoraco-abdominal aneurysms and dissections and identify predictive factors for re-intervention. METHODS We retrospectively analysed 49 patients unsuitable for surgery, treated between 2011 and 2017 (71.3 ± 9.5 years; 15 females). Indications included Crawford type 4 aneurysm in 25 patients, type 3 in 13, type 2 in 4, type 1 in 2 and chronic aneurysmal dilatation of the false lumen following dissection in 5 cases. Mean aneurysm diameter was 58.7 ± 8.4 mm. The study aims were to assess procedural success, complications rate, mortality and long-term follow-up. We also analysed factors that predicted the need for re-intervention. RESULTS The endograft was successfully deployed in all patients, catheterization of the fenestration and/or branches was achieved in 152/156 (97.4%) vessels. Early complications occurred in 10 patients (3 paraplegia, 3 haemorrhages, pancreatitis, aortic rupture, iliac artery rupture, 2 strokes). Thirty-day mortality was 10.2% and 180-day mortality 14.3%; two non procedure related deaths occurred. Mean follow-up was 23.6 ± 29.9 months [range 1-80]. No patients needed surgical explantation or developed significant renal impairment. Endoleak rate was 34.6% and re-intervention rate 9.7%. The aneurysm sac reduced or was stable in 36/49, and enlarged in 9/49 patients prompting re-intervention. Primary, primary-assisted and secondary patency of fenestrations/branches at 80 months was 90, 96 and 100%. Re-intervention was required more frequently in braches than in fenestrations, most commonly the external type branches. CONCLUSIONS The results of the Jotec endograft are comparable to other devices, with acceptable complication and re-intervention rates. Fenestration and inner-branch should be preferred due to lower re-intervention rates.
Collapse
Affiliation(s)
- Pierleone Lucatelli
- Vascular and Interventional Radiology Unit, Azienda Ospedaliera Universitaria Senese, Viale Mario Bracci, 16, 53100, Siena, Italy. .,Vascular and Interventional Radiology Unit, Sapienza University of Rome, Viale Regina Elena, 324, 00161, Rome, Italy.
| | - Marco Cini
- Vascular and Interventional Radiology Unit, Azienda Ospedaliera Universitaria Senese, Viale Mario Bracci, 16, 53100, Siena, Italy
| | - Antonio Benvenuti
- Cardiac and Great Vessels Surgery Unit, University of "Siena", Viale Mario Bracci, 16, 53100, Siena, Italy
| | - Luca Saba
- Department of Radiology, Azienda Ospedaliero Universitaria (AOU), di Cagliari - Polo di Monserrato s.s. 554, 09045, Monserrato (Cagliari), Italy
| | - Giulio Tommasino
- Cardiac and Great Vessels Surgery Unit, University of "Siena", Viale Mario Bracci, 16, 53100, Siena, Italy
| | - Giulia Guaccio
- Cardiac and Great Vessels Surgery Unit, University of "Siena", Viale Mario Bracci, 16, 53100, Siena, Italy
| | | | - Eugenio Neri
- Cardiac and Great Vessels Surgery Unit, University of "Siena", Viale Mario Bracci, 16, 53100, Siena, Italy
| | - Carmelo Ricci
- Vascular and Interventional Radiology Unit, Azienda Ospedaliera Universitaria Senese, Viale Mario Bracci, 16, 53100, Siena, Italy
| |
Collapse
|
86
|
Baba T, Ohki T, Kanaoka Y, Maeda K, Toya N, Ohta H, Fukushima S, Hara M. Clinical Outcomes of Total Endovascular Aneurysm Repair for Aortic Aneurysms Involving the Proximal Anastomotic Aneurysm following Initial Open Repair for Infrarenal Abdominal Aortic Aneurysm. Ann Vasc Surg 2018; 49:123-133. [DOI: 10.1016/j.avsg.2017.10.033] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2017] [Revised: 10/11/2017] [Accepted: 10/19/2017] [Indexed: 10/18/2022]
|
87
|
Ciani O, Epstein D, Rothery C, Taylor RS, Sculpher M. Decision uncertainty and value of further research: a case-study in fenestrated endovascular aneurysm repair for complex abdominal aortic aneurysms. COST EFFECTIVENESS AND RESOURCE ALLOCATION 2018; 16:15. [PMID: 29686541 PMCID: PMC5902886 DOI: 10.1186/s12962-018-0098-7] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2017] [Accepted: 04/07/2018] [Indexed: 11/19/2022] Open
Abstract
Background Fenestrated endovascular aneurysm repair (fEVAR) is a new approach for complex abdominal aortic aneurysms, limited to a few specialist centers, with limited evidence base. We developed a cost-effectiveness decision model of fEVAR compared to open surgical repair (OSR) to investigate the likely direction of costs and benefits and inform further research projects on this technology. Methods A systematic review with meta-analysis and a four-state Markov model were used to estimate the cost-effectiveness of fEVAR versus OSR. We used a recent coverage with evidence development framework to characterize the main sources of uncertainty and inform decisions about the type of further research that would be most worthwhile and feasible. Results Seven observational comparative studies were identified, of which four presented odds ratios adjusted for confounders. The odds ratios for operative mortality varied widely between studies. Assuming a central estimate of the odds ratio of 0.54 (95% CI 0.05–6.24), the decision model estimated that the incremental cost per quality adjusted life year (QALY) was £74,580/QALY with a probability of 9 and 16% of being cost-effective at standard cost-effectiveness thresholds of £20,000/QALY and £30,000/QALY, respectively. The Expected Value of Perfect Information over 10 years at a threshold of £20,000/QALY was £11.2 million. Operative mortality contributed to most of the uncertainty in the decision model. Conclusions In the case of “maturing technologies”, decision modelling indicates the likely direction of costs and benefits and guides the development of further research projects. In our analysis of fEVAR versus OSR, decision uncertainty, particularly around operative mortality, might be effectively resolved by a short-term RCT, or possibly a well-conducted comparative observational study. Decision makers may consider that a conditional coverage decision is warranted with assessments required to make this type of recommendation depending on local priorities and circumstances. Electronic supplementary material The online version of this article (10.1186/s12962-018-0098-7) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- Oriana Ciani
- 1Evidence Synthesis and Modeling for Health Improvement, Institute of Health Research, University of Exeter Medical School, South Cloisters, St Luke's Campus, Exeter, EX1 2LU UK.,2Center for Research on Health and Social Care Management, SDA Bocconi University, via Roentgen 1, 20136 Milan, Italy
| | - David Epstein
- 3Centre for Health Economics, University of York, Heslington, Alcuin 'A' Block, York, YO10 5DD UK.,4Department of Applied Economics, University of Granada, Campus Universitario de Cartuja, 18071 Granada, Spain
| | - Claire Rothery
- 3Centre for Health Economics, University of York, Heslington, Alcuin 'A' Block, York, YO10 5DD UK
| | - Rod S Taylor
- 1Evidence Synthesis and Modeling for Health Improvement, Institute of Health Research, University of Exeter Medical School, South Cloisters, St Luke's Campus, Exeter, EX1 2LU UK
| | - Mark Sculpher
- 3Centre for Health Economics, University of York, Heslington, Alcuin 'A' Block, York, YO10 5DD UK
| |
Collapse
|
88
|
Deery SE, Lancaster RT, Gubala AM, O'Donnell TF, Kwolek CJ, Conrad MF, Cambria RP, Patel VI. Early Experience with Fenestrated Endovascular Compared to Open Repair of Complex Abdominal Aortic Aneurysms in a High-Volume Open Aortic Center. Ann Vasc Surg 2018; 48:151-158. [DOI: 10.1016/j.avsg.2017.10.017] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2017] [Revised: 09/04/2017] [Accepted: 10/05/2017] [Indexed: 10/18/2022]
|
89
|
Huang IKH, Renani SA, Morgan RA. Complications and Reinterventions After Fenestrated and Branched EVAR in Patients with Paravisceral and Thoracoabdominal Aneurysms. Cardiovasc Intervent Radiol 2018; 41:985-997. [PMID: 29511866 DOI: 10.1007/s00270-018-1917-0] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/05/2017] [Accepted: 02/21/2018] [Indexed: 12/17/2022]
Abstract
The application of endovascular strategies to treat aneurysms involving the abdominal and thoracoabdominal aorta has evolved significantly since the inception of endovascular aneurysm repair. Advances in endograft technology and operator experience have enabled the management of a wider spectrum of challenging aortic anatomy. Fenestrated endovascular and branched endovascular aneurysm repair represent two technical innovations, which have expanded endovascular treatment options to include patients with paravisceral and thoracoabdominal aortic aneurysms. Although similar in many ways to standard aortic endografts, fenestrated and branched endografts have specific short- and long-term complications due to their unique modular endograft design and their sophisticated deployment mechanisms. This article aims to examine the commonly encountered complications with these devices and the endovascular reintervention strategies.
Collapse
Affiliation(s)
- Ivan Kuang Hsin Huang
- Department of Radiology, Tan Tock Seng Hospital, 11 Jalan Tan Tock Seng, Singapore, 308433, Singapore.
| | | | - Robert A Morgan
- Department of Radiology, St. George's Hospital NHS Trust, London, UK
| |
Collapse
|
90
|
Ertugay S, Daylan A, Bozkaya H, Oğuz E, Apaydın A, Parıldar M, Posacıoğlu H. Snorkel Technique for Inferior Mesenteric Artery During Endovascular Repair of Abdominal Aortic Aneurysm. Vasc Endovascular Surg 2018; 52:233-236. [PMID: 29433410 DOI: 10.1177/1538574418758597] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
PURPOSE The snorkel technique is commonly used to preserve renal arteries in juxta renal aneurysm during endovascular repair. Herein, we present a patient who underwent bifurcated endograft implantation with snorkel technique for inferior mesenteric artery (IMA) in order to preserve the major source of bowel circulation. CASE REPORT A 69-year-old male patient was diagnosed with abdominal aortic aneurysm. His history revealed that he had bowel resection due to a car accident 30 years ago. In addition, he was given relaparotomy 4 times due to intestinal complications. Computed tomography showed fusiform aneurysm with a maximal diameter of 60 mm and chronical occlusion of the superior mesenteric artery. Inferior mesenteric artery was found to be hypertrophic. During EVAR, 6 mm × 10 cm covered VIABAHN Endoprosthesis (Gore Medical) was implanted to the IMA over a 0.018 guidewire via puncture of the left axillary artery. Initially, the main body of the aortic stent-graft (Gore C3, size 23-14-16) was implanted to the infra renal segment of the aorta (below the renal arteries and the orifice using VIABAHN) via the right femoral artery. Next, the contralateral leg (Gore, 14-12-00) was implanted. Computed tomography was examined at 1- and 32-month postoperatively, and no endoleak or patency of IMA stent was detected. CONCLUSION In this case of IMA-dependent circulation of the intestinal system, the protection of IMA via snorkel technique was successful.
Collapse
Affiliation(s)
- Serkan Ertugay
- 1 Department of Cardiovascular Surgery, Ege University School of Medicine, Izmir, Turkey
| | - Ahmet Daylan
- 1 Department of Cardiovascular Surgery, Ege University School of Medicine, Izmir, Turkey
| | - Halil Bozkaya
- 2 Department of Radiology, Ege University School of Medicine, Izmir, Turkey
| | - Emrah Oğuz
- 1 Department of Cardiovascular Surgery, Ege University School of Medicine, Izmir, Turkey
| | - Anıl Apaydın
- 1 Department of Cardiovascular Surgery, Ege University School of Medicine, Izmir, Turkey
| | - Mustafa Parıldar
- 2 Department of Radiology, Ege University School of Medicine, Izmir, Turkey
| | - Hakan Posacıoğlu
- 1 Department of Cardiovascular Surgery, Ege University School of Medicine, Izmir, Turkey
| |
Collapse
|
91
|
Computed tomography angiography-fluoroscopy image fusion allows visceral vessel cannulation without angiography during fenestrated endovascular aneurysm repair. J Vasc Surg 2018; 68:2-11. [PMID: 29395427 DOI: 10.1016/j.jvs.2017.11.062] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2017] [Accepted: 11/02/2017] [Indexed: 11/21/2022]
Abstract
BACKGROUND Fenestrated endovascular aneurysm repair (FEVAR) is an evolving technique to treat juxtarenal abdominal aortic aneurysms (AAAs). Catheterization of visceral and renal vessels after the deployment of the fenestrated main body device is often challenging, usually requiring additional fluoroscopy and multiple digital subtraction angiograms. The aim of this study was to assess the clinical utility and accuracy of a computed tomography angiography (CTA)-fluoroscopy image fusion technique in guiding visceral vessel cannulation during FEVAR. METHODS Between August 2014 and September 2016, all consecutive patients who underwent FEVAR at our institution using image fusion guidance were included. Preoperative CTA images were fused with intraoperative fluoroscopy after coregistering with non-contrast-enhanced cone beam computed tomography (syngo 3D3D image fusion; Siemens Healthcare, Forchheim, Germany). The ostia of the visceral vessels were electronically marked on CTA images (syngo iGuide Toolbox) and overlaid on live fluoroscopy to guide vessel cannulation after fenestrated device deployment. Clinical utility of image fusion was evaluated by assessing the number of dedicated angiograms required for each visceral or renal vessel cannulation and the use of optimized C-arm angulation. Accuracy of image fusion was evaluated from video recordings by three raters using a binary qualitative assessment scale. RESULTS A total of 26 patients (17 men; mean age, 73.8 years) underwent FEVAR during the study period for juxtarenal AAA (17), pararenal AAA (6), and thoracoabdominal aortic aneurysm (3). Video recordings of fluoroscopy from 19 cases were available for review and assessment. A total of 46 vessels were cannulated; 38 of 46 (83%) of these vessels were cannulated without angiography but based only on image fusion guidance: 9 of 11 superior mesenteric artery cannulations and 29 of 35 renal artery cannulations. Binary qualitative assessment showed that 90% (36/40) of the virtual ostia overlaid on live fluoroscopy were accurate. Optimized C-arm angulations were achieved in 35% of vessel cannulations (0/9 for superior mesenteric artery cannulation, 12/25 for renal arteries). CONCLUSIONS Preoperative CTA-fluoroscopy image fusion guidance during FEVAR is a valuable and accurate tool that allows visceral and renal vessel cannulation without the need of dedicated angiograms, thus avoiding additional injection of contrast material and radiation exposure. Further refinements, such as accounting for device-induced aortic deformation and automating the image fusion workflow, will bolster this technology toward optimal routine clinical use.
Collapse
|
92
|
Gallitto E, Gargiulo M, Faggioli G, Pini R, Mascoli C, Freyrie A, Ancetti S, Stella A. Impact of iliac artery anatomy on the outcome of fenestrated and branched endovascular aortic repair. J Vasc Surg 2017; 66:1659-1667. [DOI: 10.1016/j.jvs.2017.04.063] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2016] [Accepted: 04/26/2017] [Indexed: 11/25/2022]
|
93
|
Boersen JT, Donselaar EJ, Groot Jebbink E, Starreveld R, Overeem SP, Slump CH, de Vries JPP, Reijnen MM. Benchtop quantification of gutter formation and compression of chimney stent grafts in relation to renal flow in chimney endovascular aneurysm repair and endovascular aneurysm sealing configurations. J Vasc Surg 2017; 66:1565-1573.e1. [DOI: 10.1016/j.jvs.2016.10.058] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2016] [Accepted: 10/02/2016] [Indexed: 11/29/2022]
|
94
|
Eagleton MJ, Farivar B, Dias A. Large, single-center databases and the evolution of endovascular therapy for complex aortic aneurysms. Surgery 2017; 162:963-973. [DOI: 10.1016/j.surg.2017.03.018] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2017] [Accepted: 03/21/2017] [Indexed: 11/15/2022]
|
95
|
Budtz-Lilly J, Wanhainen A, Eriksson J, Mani K. Adapting to a total endovascular approach for complex aortic aneurysm repair: Outcomes after fenestrated and branched endovascular aortic repair. J Vasc Surg 2017. [DOI: 10.1016/j.jvs.2017.03.422] [Citation(s) in RCA: 38] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
96
|
Psacharopulo D, Ferri M, Ferrero E, Bahia SS, Viazzo A, Pecchio A, Ricceri F, Nessi F. Comparison of outcomes for short-neck and juxtarenal aortic aneurysms treated with the Nellix endograft versus conventional endovascular aneurysm sealing. J Vasc Surg 2017; 66:1371-1378. [DOI: 10.1016/j.jvs.2017.03.444] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2016] [Accepted: 03/23/2017] [Indexed: 12/17/2022]
|
97
|
Ragusi MAAD, van der Meer RW, Joemai RMS, van Schaik J, van Rijswijk CSP. Evaluation of CT Angiography Image Quality Acquired with Single-Energy Metal Artifact Reduction (SEMAR) Algorithm in Patients After Complex Endovascular Aortic Repair. Cardiovasc Intervent Radiol 2017; 41:323-329. [PMID: 29086057 PMCID: PMC5758681 DOI: 10.1007/s00270-017-1812-0] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/05/2017] [Accepted: 10/09/2017] [Indexed: 11/25/2022]
Abstract
Purpose To evaluate the value of single-energy metal artifact reduction (SEMAR) algorithm on image quality in patients after complex endovascular aortic repair (EVAR) with fenestrated and branched devices. Methods Routine follow-up computed tomography angiography (CTA) examinations were performed between February 2016 and May 2017 in 18 patients who underwent a complex EVAR procedure at our institution. Objective analysis was performed by measuring the standard deviation (SD) of attenuation (Hounsfield Units), and the contrast-to-noise ratio (CNR) in regions of interests in the stented visceral arteries. Subjective analysis of the degree of artifacts and stent visualization was performed independently by two interventional radiologists, blinded to the image reconstruction. Results The SD of attenuation was significantly lower in all target visceral arteries (p < .001), the celiac artery (p = .002), the superior mesenteric artery (SMA; p = .043), and renal arteries (p < .001) in the CT images with SEMAR reconstruction. The CNR significantly increased in all SEMAR-reconstructed target visceral arteries (overall: p < .001, celiac artery: p = .009; SMA: p = .003; renal arteries: p < .001). The reviewers rated a significantly lower artifact degree in all target vessels (overall: p < .001, celiac artery: p = .001; SMA: p = .008; renal arteries: p < .001) and a significantly improved visualization of the stent patency in all target vessels (overall: p < .001, celiac artery: p = .031; SMA: p = .047; renal arteries: p < .001) in the SEMAR images. Overall preference of both reviewers was in favor of the SEMAR reconstruction in 15/18 cases (83%). Conclusion Reconstruction with SEMAR algorithm significantly improves CTA image quality in patients after complex EVAR. Level of Evidence Level 4, Case series.
Collapse
Affiliation(s)
- M A A D Ragusi
- Department of Radiology, Leiden University Medical Center, Albinusdreef 2, P.O. Box 9600, 2300RC, Leiden, The Netherlands.
| | - R W van der Meer
- Department of Radiology, Leiden University Medical Center, Albinusdreef 2, P.O. Box 9600, 2300RC, Leiden, The Netherlands
| | - R M S Joemai
- Department of Radiology, Leiden University Medical Center, Albinusdreef 2, P.O. Box 9600, 2300RC, Leiden, The Netherlands
| | - J van Schaik
- Department of Surgery, Leiden University Medical Center, Albinusdreef 2, P.O. Box 9600, 2300RC, Leiden, The Netherlands
| | - C S P van Rijswijk
- Department of Radiology, Leiden University Medical Center, Albinusdreef 2, P.O. Box 9600, 2300RC, Leiden, The Netherlands
| |
Collapse
|
98
|
Montelione N, Sirignano P, Mansour W, Formiconi M, Capoccia L, Speziale F. Chimney Technique with the INCRAFT ® AAA Stent Graft System to Treat Pararenal Aortic Aneurysm in Narrowed Iliac Axes. Ann Vasc Surg 2017; 44:421.e9-421.e13. [DOI: 10.1016/j.avsg.2017.03.199] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2017] [Revised: 03/11/2017] [Accepted: 03/26/2017] [Indexed: 10/19/2022]
|
99
|
Sattah AP, Secrist MH, Sarin S. Complications and Perioperative Management of Patients Undergoing Thoracic Endovascular Aortic Repair. J Intensive Care Med 2017; 33:394-406. [PMID: 28946776 DOI: 10.1177/0885066617730571] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Endovascular treatments have become increasingly common for patients with a variety of thoracic aortic pathologies. Although considered less invasive than traditional open surgical approaches, they are nonetheless complex procedures. Patients undergo manipulation of an often calcified aorta near the origin of the carotid and subclavian vessels and have stents placed in a curved vessel adjacent to a perpetually beating heart. These stents can obstruct blood flow to the spinal cord, induce an inflammatory response, and in rare cases erode into the adjacent trachea or esophagus. Renal complications range from contrast-induced nephropathy to hypotension and ischemia to dissection. Emboli can lead to strokes and mesenteric ischemia. These patients have complex medical histories, and skilled perioperative management is critical to achieving the best clinical outcomes. Here, we review the medical management of the most common complications in these patients including stroke, spinal cord ischemia, renal injury, retrograde dissections, aortoesophageal and aortobronchial fistulas, postimplantation syndrome, mesenteric ischemia, and endograft failure.
Collapse
Affiliation(s)
- Anna P Sattah
- 1 School of Arts and Sciences, Duke University, Durham, NC, USA.,2 School of Medicine and Department of Surgery, University of Virginia, Charlottesville, VA, USA.,3 Department of Anesthesia and Critical Care, George Washington University Medical Center, Washington, DC, USA.,4 Holy Cross Hospital, Silver Spring, MD, USA
| | - Michael H Secrist
- 5 College of Humanities, Brigham Young University, Provo, UT, USA.,6 Doctor of Medicine, Medical College of Wisconsin, Milwaukee, WI, USA.,7 Department of Interventional Radiology, University of California, Irvine, CA, USA.,8 Department of Radiology, George Washington University Medical Center, Washington, DC, USA
| | - Shawn Sarin
- 2 School of Medicine and Department of Surgery, University of Virginia, Charlottesville, VA, USA.,9 Kasturba Medical College, Karnataka, India.,10 Northeast Ohio Medical Universities, Rootstown, OH, USA.,11 Department of Interventional Radiology, National Institutes of Health, Stapleton, New York City, NY, USA.,12 Department of Interventional Radiology, George Washington University Medical Center, Washington, DC, USA
| |
Collapse
|
100
|
Shiraev TP, Kwok TMY, Dubenec SR. Medium-term outcomes of fenestrated endovascular repair of juxtarenal abdominal aortic aneurysms. ANZ J Surg 2017; 88:306-310. [PMID: 28922688 DOI: 10.1111/ans.14162] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2016] [Revised: 04/26/2017] [Accepted: 06/05/2017] [Indexed: 11/26/2022]
Abstract
BACKGROUND Abdominal aortic aneurysms pose a substantial clinical burden, and a significant proportion are not anatomically suitable for open repair or standard endovascular aneurysm repair (EVAR), instead requiring fenestrated EVAR (fEVAR). We sought to compare clinical outcomes and trends over time in patients undergoing fEVAR in Australia. METHODS We conducted a retrospective analysis of all patients undergoing fEVAR at a tertiary referral centre between 2010 and 2015, including outcomes and complications, both as inpatients and after discharge. RESULTS Thirty-nine patients underwent fEVAR during the study period, with mean age of 75 years and mean aneurysm size of 61 mm. One hundred and thirty-four target vessels were treated and inhospital mortality was 5% (two patients). There were nine inhospital, eight Type II and one Type III endoleaks. Ten patients suffered acute kidney injury, one of whom required dialysis. Mean follow-up was 14.5 months (range: 0-46.7). Target vessel patency was 99.2% at follow-up. There were six Type II endoleaks at follow-up, and two patients died during the follow-up period (of non-aneurysm-related causes). CONCLUSION fEVAR is an effective treatment with low morbidity and mortality, and we have demonstrated excellent survival and target vessel patency at a mean follow-up of 14 months. Endoleak rates were low, despite the high complexity of the aneurysms treated.
Collapse
Affiliation(s)
- Timothy P Shiraev
- Department of Vascular Surgery, Royal Prince Alfred Hospital, Sydney, New South Wales, Australia
| | - Trevor M Y Kwok
- Department of Vascular Surgery, Royal Prince Alfred Hospital, Sydney, New South Wales, Australia
| | - Steven R Dubenec
- Department of Vascular Surgery, Royal Prince Alfred Hospital, Sydney, New South Wales, Australia
| |
Collapse
|