51
|
Fuchs A, Kofoed KF, Yoon SH, Schaffner Y, Bieliauskas G, Thyregod HG, Makkar R, Søndergaard L, De Backer O, Bapat V. Commissural Alignment of Bioprosthetic Aortic Valve and Native Aortic Valve Following Surgical and Transcatheter Aortic Valve Replacement and its Impact on Valvular Function and Coronary Filling. JACC Cardiovasc Interv 2018; 11:1733-1743. [DOI: 10.1016/j.jcin.2018.05.043] [Citation(s) in RCA: 49] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/12/2018] [Revised: 05/22/2018] [Accepted: 05/29/2018] [Indexed: 10/28/2022]
|
52
|
Study on the Accuracy of Structural and FSI Heart Valves Simulations. Cardiovasc Eng Technol 2018; 9:723-738. [DOI: 10.1007/s13239-018-00373-3] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/08/2018] [Accepted: 08/11/2018] [Indexed: 12/29/2022]
|
53
|
Peeters FECM, Meex SJR, Dweck MR, Aikawa E, Crijns HJGM, Schurgers LJ, Kietselaer BLJH. Calcific aortic valve stenosis: hard disease in the heart: A biomolecular approach towards diagnosis and treatment. Eur Heart J 2018; 39:2618-2624. [PMID: 29136138 PMCID: PMC6055545 DOI: 10.1093/eurheartj/ehx653] [Citation(s) in RCA: 118] [Impact Index Per Article: 19.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/18/2017] [Revised: 10/05/2017] [Accepted: 10/27/2017] [Indexed: 12/19/2022] Open
Abstract
Calcific aortic valve stenosis (CAVS) is common in the ageing population and set to become an increasing economic and health burden. Once present, it inevitably progresses and has a poor prognosis in symptomatic patients. No medical therapies are proven to be effective in holding or reducing disease progression. Therefore, aortic valve replacement remains the only available treatment option. Improved knowledge of the mechanisms underlying disease progression has provided us with insights that CAVS is not a passive disease. Rather, CAVS is regulated by numerous mechanisms with a key role for calcification. Aortic valve calcification (AVC) is actively regulated involving cellular and humoral factors that may offer targets for diagnosis and intervention. The discovery that the vitamin K-dependent proteins are involved in the inhibition of AVC has boosted our mechanistic understanding of this process and has opened up novel avenues in disease exploration. This review discusses processes involved in CAVS progression, with an emphasis on recent insights into calcification, methods for imaging calcification activity, and potential therapeutic options.
Collapse
Affiliation(s)
| | - Steven J R Meex
- Department of Clinical Chemistry, MUMC+, P. Debyelaan 25, HX Maastricht, the Netherlands
| | - Marc R Dweck
- Centre for Cardiovascular Science, University of Edinburgh, 47 Little France Crescent, Edinburgh, UK
| | - Elena Aikawa
- Department of Medicine, Cardiovascular Division, Brigham and Women’s Hospital, Harvard Medical School, 75 Francis Street, Boston, MA, USA
| | - Harry J G M Crijns
- Department of Cardiology, MUMC+ and CARIM, P. Debyelaan 25, HX Maastricht, the Netherlands
| | - Leon J Schurgers
- Department of Biochemistry and CARIM, Maastricht University, PO Box 616, MD Maastricht, The Netherlands
| | - Bas L J H Kietselaer
- Department of Cardiology, MUMC+ and CARIM, P. Debyelaan 25, HX Maastricht, the Netherlands
| |
Collapse
|
54
|
Sanford RM, Crawford SA, Genis H, Doyle MG, Forbes TL, Amon CH. Predicting Rotation in Fenestrated Endovascular Aneurysm Repair Using Finite Element Analysis. J Biomech Eng 2018; 140:2681000. [DOI: 10.1115/1.4040124] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2017] [Indexed: 01/20/2023]
Abstract
Fenestrated endovascular aneurysm repair (FEVAR) is a minimally invasive method of abdominal aortic aneurysm (AAA) repair utilized in patients with complex vessel anatomies. Stent grafts (SG) used in this process contain fenestrations within the device that need to be aligned with the visceral arteries upon successful SG deployment. Proper alignment is crucial to maintain blood flow to these arteries and avoid surgical complications. During fenestrated SG deployment, rotation of the SG can occur during the unsheathing process. This leads to misalignment of the vessels, and the fenestrations and is associated with poor clinical outcomes. The aim of this study was to develop a computational model of the FEVAR process to predict SG rotation. Six patient-specific cases are presented and compared with surgical case data. Realistic material properties, frictional effects, deployment methods, and boundary conditions are included in the model. A mean simulation error of 2 deg (range 1–4 deg) was observed. This model was then used to conduct a parameter study of frictional properties to see if rotation could be minimized. This study showed that increasing or decreasing the coefficients of friction (COF) between the sheath and the vessel walls would decrease the amount of rotation observed. Our model accurately predicts the amount of SG rotation observed during FEVAR and can be used as a preoperative planning tool within the surgical workflow.
Collapse
Affiliation(s)
- Ryan M. Sanford
- Department of Mechanical and Industrial Engineering, University of Toronto, Toronto, ON M5S 3G8, Canada
| | - Sean A. Crawford
- Division of Vascular Surgery, Peter Munk Cardiac Centre, University Health Network and University of Toronto, Toronto, ON M5G 2C4, Canada
- Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, ON M5S 3G9, Canada
| | - Helen Genis
- Division of Vascular Surgery, Peter Munk Cardiac Centre, University Health Network and University of Toronto, Toronto, ON M5G 2C4, Canada
| | - Matthew G. Doyle
- Department of Mechanical and Industrial Engineering, University of Toronto, Toronto, ON M5S 3G8, Canada
- Division of Vascular Surgery, Peter Munk Cardiac Centre, University Health Network and University of Toronto, Toronto, ON M5G 2C4, Canada
| | - Thomas L. Forbes
- Division of Vascular Surgery, Peter Munk Cardiac Centre, University Health Network and University of Toronto, Toronto, ON M5G 2C4, Canada
| | - Cristina H. Amon
- Department of Mechanical and Industrial Engineering, University of Toronto, Toronto, ON M5S 3G8, Canada
- Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, ON M5S 3G9, Canada
| |
Collapse
|
55
|
Bosi GM, Capelli C, Cheang MH, Delahunty N, Mullen M, Taylor AM, Schievano S. Population-specific material properties of the implantation site for transcatheter aortic valve replacement finite element simulations. J Biomech 2018; 71:236-244. [PMID: 29482928 PMCID: PMC5889787 DOI: 10.1016/j.jbiomech.2018.02.017] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2017] [Revised: 02/07/2018] [Accepted: 02/09/2018] [Indexed: 10/31/2022]
Abstract
Patient-specific computational models are an established tool to support device development and test under clinically relevant boundary conditions. Potentially, such models could be used to aid the clinical decision-making process for percutaneous valve selection; however, their adoption in clinical practice is still limited to individual cases. To be fully informative, they should include patient-specific data on both anatomy and mechanics of the implantation site. In this work, fourteen patient-specific computational models for transcatheter aortic valve replacement (TAVR) with balloon-expandable Sapien XT devices were retrospectively developed to tune the material parameters of the implantation site mechanical model for the average TAVR population. Pre-procedural computed tomography (CT) images were post-processed to create the 3D patient-specific anatomy of the implantation site. Balloon valvuloplasty and device deployment were simulated with finite element (FE) analysis. Valve leaflets and aortic root were modelled as linear elastic materials, while calcification as elastoplastic. Material properties were initially selected from literature; then, a statistical analysis was designed to investigate the effect of each implantation site material parameter on the implanted stent diameter and thus identify the combination of material parameters for TAVR patients. These numerical models were validated against clinical data. The comparison between stent diameters measured from post-procedural fluoroscopy images and final computational results showed a mean difference of 2.5 ± 3.9%. Moreover, the numerical model detected the presence of paravalvular leakage (PVL) in 79% of cases, as assessed by post-TAVR echocardiographic examination. The final aim was to increase accuracy and reliability of such computational tools for prospective clinical applications.
Collapse
Affiliation(s)
- Giorgia M Bosi
- Centre for Cardiovascular Imaging, UCL Institute of Cardiovascular Science & Great Ormond Street Hospital for Children, London, UK; Cardiovascular Engineering Laboratory, UCL Mechanical Engineering, London, UK.
| | - Claudio Capelli
- Centre for Cardiovascular Imaging, UCL Institute of Cardiovascular Science & Great Ormond Street Hospital for Children, London, UK
| | - Mun Hong Cheang
- Barts Health NHS Trust, University College London Hospital, London, UK
| | - Nicola Delahunty
- Barts Health NHS Trust, University College London Hospital, London, UK
| | - Michael Mullen
- Barts Health NHS Trust, University College London Hospital, London, UK
| | - Andrew M Taylor
- Centre for Cardiovascular Imaging, UCL Institute of Cardiovascular Science & Great Ormond Street Hospital for Children, London, UK
| | - Silvia Schievano
- Centre for Cardiovascular Imaging, UCL Institute of Cardiovascular Science & Great Ormond Street Hospital for Children, London, UK
| |
Collapse
|
56
|
Arzani A, Mofrad MR. A strain-based finite element model for calcification progression in aortic valves. J Biomech 2017; 65:216-220. [DOI: 10.1016/j.jbiomech.2017.10.014] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2017] [Revised: 10/12/2017] [Accepted: 10/15/2017] [Indexed: 11/28/2022]
|
57
|
Finite element analysis of TAVI: Impact of native aortic root computational modeling strategies on simulation outcomes. Med Eng Phys 2017; 47:2-12. [DOI: 10.1016/j.medengphy.2017.06.045] [Citation(s) in RCA: 43] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2017] [Revised: 06/21/2017] [Accepted: 06/25/2017] [Indexed: 01/08/2023]
|
58
|
Petrini L, Bertini A, Berti F, Pennati G, Migliavacca F. The role of inelastic deformations in the mechanical response of endovascular shape memory alloy devices. Proc Inst Mech Eng H 2017; 231:391-404. [PMID: 28427320 DOI: 10.1177/0954411917696336] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
Abstract
Nickel-titanium alloys are commonly adopted for producing cardiovascular minimally invasive devices such as self-expandable stents, aortic valves and stent-grafts. These devices are subjected to cyclic loads (due to blood pulsatility, leg or heart movements), that can induce fatigue fracture, and may also be subjected to very large deformations (due to crimping procedure, a tortuous physiological path or overloads), that can induce material yield. Recently, the authors developed a new constitutive model that considers inelastic strains due to not-completed reverse phase transformation (not all the stress-induced martensite turns back to austenite) or/and plasticity and their accumulation during cyclic loads. In this article, the model is implemented in the finite element code ABAQUS/Standard and it is used to investigate the effects of inelastic strain accumulation on endovascular nickel-titanium devices. In particular, the behavior of a transcatheter aortic valve is studied considering the following steps: (1) crimping, (2) expansion in a tube resembling a durability test chamber and (3) cyclic loads due to pressure variation applied on the inner surface of the tube. The analyses are performed twice, activating and not activating that part of the new model which describes the development of irreversible strain. From the results, it is interesting to note that plasticity has a very significant effect on the local material response, inducing stress modification from compression to tension. However, permanent deformations are concentrated in few zones of the stent frame and their presence does not affect the global behavior of the device that maintains its capability of recovering the original shape. In conclusion, this work suggests that at least for cardiovascular devices where the crimping is high (local strain may reach values of 8%-9%), taking into account inelastic effects due to plasticity and not-completed reverse phase transformation can be important, and hence using a suitable constitutive model is recommended.
Collapse
Affiliation(s)
- Lorenza Petrini
- 1 Laboratory of Biological Structure Mechanics, Department of Civil and Environmental Engineering, Politecnico di Milano, Milan, Italy
| | - Alessandro Bertini
- 2 Laboratory of Biological Structure Mechanics, Department of Chemistry, Materials and Chemical Engineering "Giulio Natta", Politecnico di Milano, Milan, Italy
| | - Francesca Berti
- 2 Laboratory of Biological Structure Mechanics, Department of Chemistry, Materials and Chemical Engineering "Giulio Natta", Politecnico di Milano, Milan, Italy
| | - Giancarlo Pennati
- 2 Laboratory of Biological Structure Mechanics, Department of Chemistry, Materials and Chemical Engineering "Giulio Natta", Politecnico di Milano, Milan, Italy
| | - Francesco Migliavacca
- 2 Laboratory of Biological Structure Mechanics, Department of Chemistry, Materials and Chemical Engineering "Giulio Natta", Politecnico di Milano, Milan, Italy
| |
Collapse
|
59
|
Bailey J, Curzen N, Bressloff NW. The impact of imperfect frame deployment and rotational orientation on stress within the prosthetic leaflets during transcatheter aortic valve implantation. J Biomech 2017; 53:22-28. [DOI: 10.1016/j.jbiomech.2016.12.031] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2016] [Revised: 12/13/2016] [Accepted: 12/19/2016] [Indexed: 10/20/2022]
|
60
|
Marino M, Korossis S. Cardiovascular biomechanics in health and disease. J Biomech 2016; 49:2319-20. [PMID: 27240751 DOI: 10.1016/j.jbiomech.2016.04.030] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Affiliation(s)
- Michele Marino
- Institute of Continuum Mechanics, Leibniz Universität Hannover, Appelstraße 11, 30167 Hannover, Germany.
| | - Sotirios Korossis
- Department of Cardiothoracic, Transplantation and Vascular Surgery, Lower Saxony Centre for Biomedical Engineering, Implant Research and Development, Hannover Medical School, Stadtfelddamm 34, 30625 Hannover, Germany.
| |
Collapse
|