51
|
The use of microfluidics in hemostasis: clinical diagnostics and biomimetic models of vascular injury. Curr Opin Hematol 2013; 20:417-23. [PMID: 23872531 DOI: 10.1097/moh.0b013e3283642186] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
PURPOSE OF REVIEW This article reviews the application of microfluidic technologies in hemostasis. The emphasis is on promising developments in devices for clinical applications and novel approaches to modeling complex hemodynamics. RECENT FINDINGS Microfluidics combined with micropatterning of prothrombotic substrates provides devices for measuring platelet function and coagulation with low blood volumes (∼100 μl) over a wide range of shear stresses. This technology has been applied to the diagnosis of bleeding and thrombotic disorders, as well as to dosing and monitoring of anticoagulation and antiplatelet agents. Microfluidic devices that mimic vascular geometries such as bifurcations, stenosis, and complex interconnected networks yield complex flow fields that have revealed new mechanisms of platelet adhesion and aggregation. Applying techniques from tissue engineering by endothelializing these networks is beginning to close the gap between in-vitro and in-vivo models of vascular injury. SUMMARY Microfluidic technology enables researchers to create in-vitro models of vascular disease with unprecedented control of the biochemical and biophysical conditions. Two promising directions are flow-dependent clinical assays and biomimetic vascular networks. These approaches are particularly well suited for modeling the microvasculature. However, caution should be used when extrapolating results from microfluidic channels to the pathophysiology of thrombosis in large arteries and veins.
Collapse
|
52
|
Li CW, Wang GJ. A material-independent cell-environment niche based on microreciprocating motion for cell growth enhancement. Biofabrication 2013; 5:045001. [PMID: 23988498 DOI: 10.1088/1758-5082/5/4/045001] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
In tissue engineering, cell-cell, cell-scaffold and cell-environment communication balances regulate how cell populations participate in tissue generation, maintenance and repair. These communication balances are called niches. In this study, an easily implemented and material-independent cell-environment niche based on microreciprocating motions is developed to enhance cell growth. A micropositioning piezoelectric lead zirconate titanate stage is used to provide precise microreciprocating shear stress motions. Various shear stresses were applied to bovine endothelial cells (BECs) that were cultured on the artificially synthesized materials to obtain the suitable shear stress for growth enhancement. It was found that the suitable shear stress for apparent enhancement of BEC growth ranges from 1.8 to 2.2 N m(-2). Biopolymers were further used to verify the feasibility of the proposed approach using the optimized shear stress obtained from the culture on artificially synthesized polymers. The results further confirmed that the growth of BECs was enhanced as expected under the calculated reciprocating frequencies based on the suitable shear stress. It is hoped that the proposed microshear-stress-based niche could be a more cost- and time-effective solution for the enhancement of cell growth in tissue engineering applications.
Collapse
Affiliation(s)
- Ching-Wen Li
- Ph.D. Program in Tissue Engineering and Regenerative Medicine, National Chung Hsing University, Taichung 402, Taiwan
| | | |
Collapse
|
53
|
Chung IC, Li CW, Wang GJ. The influence of different nanostructured scaffolds on fibroblast growth. SCIENCE AND TECHNOLOGY OF ADVANCED MATERIALS 2013; 14:044401. [PMID: 27877586 PMCID: PMC5090312 DOI: 10.1088/1468-6996/14/4/044401] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/15/2013] [Accepted: 05/15/2013] [Indexed: 06/06/2023]
Abstract
Skin serves as a protective barrier, modulating body temperature and waste discharge. It is therefore desirable to be able to repair any damage that occurs to the skin as soon as possible. In this study, we demonstrate a relatively easy and cost-effective method for the fabrication of nanostructured scaffolds, to shorten the time taken for a wound to heal. Various scaffolds consisting of nanohemisphere arrays of poly(lactic-co-glycolic acid) (PLGA), polylactide and chitosan were fabricated by casting using a nickel (Ni) replica mold. The Ni replica mold is electroformed using the highly ordered nanohemisphere array of the barrier-layer surface of an anodic aluminum oxide membrane as the template. Mouse fibroblast cells (L929s) were cultured on the nanostructured polymer scaffolds to investigate the effect of these different nanohemisphere arrays on cell proliferation. The concentration of collagen type I on each scaffold was then measured through enzyme-linked immunosorbent assay to find the most effective scaffold for shortening the wound-healing process. The experimental data indicate that the proliferation of L929 is superior when a nanostructured PLGA scaffold with a feature size of 118 nm is utilized.
Collapse
Affiliation(s)
- I-Cheng Chung
- Graduate Institute of Biomedical Engineering, National Chung-Hsing University, Taichung 40227, Taiwan
| | - Ching-Wen Li
- PhD Program in Tissue Engineering and Regenerative Medicine, National Chung-Hsing University, Taichung 40227, Taiwan
| | - Gou-Jen Wang
- Graduate Institute of Biomedical Engineering, National Chung-Hsing University, Taichung 40227, Taiwan; PhD Program in Tissue Engineering and Regenerative Medicine, National Chung-Hsing University, Taichung 40227, Taiwan; Department of Mechanical Engineering, National Chung-Hsing University, Taichung 40227, Taiwan
| |
Collapse
|
54
|
Rajagopalan P, Kasif S, Murali T. Systems Biology Characterization of Engineered Tissues. Annu Rev Biomed Eng 2013; 15:55-70. [DOI: 10.1146/annurev-bioeng-071811-150120] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Affiliation(s)
- Padmavathy Rajagopalan
- Department of Chemical Engineering, Virginia Tech, Blacksburg, Virginia 24060;
- School of Biomedical Engineering and Sciences, Virginia Tech, Blacksburg, Virginia 24060
- ICTAS Center for Systems Biology of Engineered Tissues, Virginia Tech, Blacksburg, Virginia 24060
| | - Simon Kasif
- Department of Biomedical Engineering, Boston University, Boston, Massachusetts 02215
| | - T.M. Murali
- Department of Computer Science, Virginia Tech, Blacksburg, Virginia 24060
- ICTAS Center for Systems Biology of Engineered Tissues, Virginia Tech, Blacksburg, Virginia 24060
| |
Collapse
|
55
|
Prabhakarpandian B, Shen MC, Nichols JB, Mills IR, Sidoryk-Wegrzynowicz M, Aschner M, Pant K. SyM-BBB: a microfluidic Blood Brain Barrier model. LAB ON A CHIP 2013; 13:1093-101. [PMID: 23344641 PMCID: PMC3613157 DOI: 10.1039/c2lc41208j] [Citation(s) in RCA: 197] [Impact Index Per Article: 17.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
Current techniques for mimicking the Blood-Brain Barrier (BBB) largely use incubation chambers (Transwell) separated with a filter and matrix coating to represent and to study barrier permeability. These devices have several critical shortcomings: (a) they do not reproduce critical microenvironmental parameters, primarily anatomical size or hemodynamic shear stress, (b) they often do not provide real-time visualization capability, and (c) they require a large amount of consumables. To overcome these limitations, we have developed a microfluidics based Synthetic Microvasculature model of the Blood-Brain Barrier (SyM-BBB). The SyM-BBB platform is comprised of a plastic, disposable and optically clear microfluidic chip with a microcirculation sized two-compartment chamber. The chamber is designed in such a way as to permit the realization of side-by-side apical and basolateral compartments, thereby simplifying fabrication and facilitating integration with standard instrumentation. The individually addressable apical side is seeded with endothelial cells and the basolateral side can support neuronal cells or conditioned media. In the present study, an immortalized Rat Brain Endothelial cell line (RBE4) was cultured in SyM-BBB with a perfusate of Astrocyte Conditioned Media (ACM). Biochemical analysis showed upregulation of tight junction molecules while permeation studies showed an intact BBB. Finally, transporter assay was successfully demonstrated in SyM-BBB indicating a functional model.
Collapse
|
56
|
Abstract
Controlled expansion and differentiation of pluripotent stem cells (PSCs) using reproducible, high-throughput methods could accelerate stem cell research for clinical therapies. Hydrodynamic culture systems for PSCs are increasingly being used for high-throughput studies and scale-up purposes; however, hydrodynamic cultures expose PSCs to complex physical and chemical environments that include spatially and temporally modulated fluid shear stresses and heterogeneous mass transport. Furthermore, the effects of fluid flow on PSCs cannot easily be attributed to any single environmental parameter since the cellular processes regulating self-renewal and differentiation are interconnected and the complex physical and chemical parameters associated with fluid flow are thus difficult to independently isolate. Regardless of the challenges posed by characterizing fluid dynamic properties, hydrodynamic culture systems offer several advantages over traditional static culture, including increased mass transfer and reduced cell handling. This article discusses the challenges and opportunities of hydrodynamic culture environments for the expansion and differentiation of PSCs in microfluidic systems and larger-volume suspension bioreactors. Ultimately, an improved understanding of the effects of hydrodynamics on the self-renewal and differentiation of PSCs could yield improved bioprocessing technologies to attain scalable PSC culture strategies that will probably be requisite for the development of therapeutic and diagnostic applications.
Collapse
|
57
|
Hansen RR, Wufsus AR, Barton ST, Onasoga AA, Johnson-Paben RM, Neeves KB. High content evaluation of shear dependent platelet function in a microfluidic flow assay. Ann Biomed Eng 2012; 41:250-62. [PMID: 23001359 DOI: 10.1007/s10439-012-0658-5] [Citation(s) in RCA: 46] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2012] [Accepted: 09/11/2012] [Indexed: 12/14/2022]
Abstract
The high blood volume requirements and low throughput of conventional flow assays for measuring platelet function are unsuitable for drug screening and clinical applications. In this study, we describe a microfluidic flow assay that uses 50 μL of whole blood to measure platelet function on ~300 micropatterned spots of collagen over a range of physiologic shear rates (50-920 s(-1)). Patterning of collagen thin films (CTF) was achieved using a novel hydrated microcontact stamping method. CTF spots of 20, 50, and 100 μm were defined on glass substrates and consisted of a dense mat of nanoscale collagen fibers (3.74 ± 0.75 nm). We found that a spot size of greater than 20 μm was necessary to support platelet adhesion under flow, suggesting a threshold injury size is necessary for stable platelet adhesion. Integrating 50 μm CTF microspots into a multishear microfluidic device yielded a high content assay from which we extracted platelet accumulation metrics (lag time, growth rate, total accumulation) on the spots using Hoffman modulation contrast microscopy. This method has potential broad application in identifying platelet function defects and screening, monitoring, and dosing antiplatelet agents.
Collapse
Affiliation(s)
- Ryan R Hansen
- Department of Chemical and Biological Engineering, Colorado School of Mines, Golden, CO 80401, USA
| | | | | | | | | | | |
Collapse
|
58
|
Lee J, Paek J, Kim J. Sucrose-based fabrication of 3D-networked, cylindrical microfluidic channels for rapid prototyping of lab-on-a-chip and vaso-mimetic devices. LAB ON A CHIP 2012; 12:2638-42. [PMID: 22699280 DOI: 10.1039/c2lc40267j] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/16/2023]
Abstract
We present a new fabrication scheme for 3D-networked, cylindrical microfluidic (MF) channels based on shaping, bonding, and assembly of sucrose fibers. It is a simple, cleanroom-free, and environment-friendly method, ideal for rapid prototyping of lab-on-a-chip devices. Despite its simplicity, it can realize complex 3D MF channel architectures such as cylindrical tapers, internal loops, end-to-side junctions, tapered junctions, and stenosis. The last two will be of special use for realizing vaso-mimetic MF structures. It also enables molding with polymers incompatible with high-temperature processing.
Collapse
Affiliation(s)
- Jiwon Lee
- Department of Electrical and Computer Engineering, Iowa State University, Ames, Iowa 50011, USA
| | | | | |
Collapse
|
59
|
Forouzan O, Yang X, Sosa JM, Burns JM, Shevkoplyas SS. Spontaneous oscillations of capillary blood flow in artificial microvascular networks. Microvasc Res 2012; 84:123-32. [PMID: 22732344 DOI: 10.1016/j.mvr.2012.06.006] [Citation(s) in RCA: 38] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2012] [Revised: 06/12/2012] [Accepted: 06/13/2012] [Indexed: 10/28/2022]
Abstract
Previous computational studies have suggested that the capillary blood flow oscillations frequently observed in vivo can originate spontaneously from the non-linear rheological properties of blood, without any regulatory input. Testing this hypothesis definitively in experiments involving real microvasculature has been difficult because in vivo the blood flow in capillaries is always actively controlled by the host. The objective of this study was to test the hypothesis experimentally and to investigate the relative contribution of different blood cells to the capillary blood flow dynamics under static boundary conditions and in complete isolation from the active regulatory mechanisms mediated by the blood vessels in vivo. To accomplish this objective, we passed whole blood and re-constituted blood samples (purified red blood cells suspended in buffer or in autologous plasma) through an artificial microvascular network (AMVN) comprising completely inert, microfabricated vessels with the architecture inspired by the real microvasculature. We found that the flow of blood in capillaries of the AMVN indeed oscillates with characteristic frequencies in the range of 0-0.6 Hz, which is in a very good agreement with previous computational studies and in vivo observations. We also found that the traffic of leukocytes through the network (typically neglected in computational modeling) plays an important role in generating the oscillations. This study represents the key piece of experimental evidence in support of the hypothesis that spontaneous, self-sustained oscillations of capillary blood flow can be generated solely by the non-linear rheological properties of blood flowing through microvascular networks, and provides an insight into the mechanism of this fundamentally important microcirculatory phenomenon.
Collapse
Affiliation(s)
- Omid Forouzan
- Department of Biomedical Engineering, Tulane University, New Orleans, LA 70118, United States
| | | | | | | | | |
Collapse
|
60
|
Myers DR, Sakurai Y, Tran R, Ahn B, Hardy ET, Mannino R, Kita A, Tsai M, Lam WA. Endothelialized microfluidics for studying microvascular interactions in hematologic diseases. J Vis Exp 2012:3958. [PMID: 22760254 DOI: 10.3791/3958] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/31/2022] Open
Abstract
Advances in microfabrication techniques have enabled the production of inexpensive and reproducible microfluidic systems for conducting biological and biochemical experiments at the micro- and nanoscales (1,2). In addition, microfluidics have also been specifically used to quantitatively analyze hematologic and microvascular processes, because of their ability to easily control the dynamic fluidic environment and biological conditions(3-6). As such, researchers have more recently used microfluidic systems to study blood cell deformability, blood cell aggregation, microvascular blood flow, and blood cell-endothelial cell interactions(6-13).However, these microfluidic systems either did not include cultured endothelial cells or were larger than the sizescale relevant to microvascular pathologic processes. A microfluidic platform with cultured endothelial cells that accurately recapitulates the cellular, physical, and hemodynamic environment of the microcirculation is needed to further our understanding of the underlying biophysical pathophysiology of hematologic diseases that involve the microvasculature. Here, we report a method to create an "endothelialized" in vitro model of the microvasculature, using a simple, single mask microfabrication process in conjunction with standard endothelial cell culture techniques, to study pathologic biophysical microvascular interactions that occur in hematologic disease. This "microvasculature-on-a-chip" provides the researcher with a robust assay that tightly controls biological as well as biophysical conditions and is operated using a standard syringe pump and brightfield/fluorescence microscopy. Parameters such as microcirculatory hemodynamic conditions, endothelial cell type, blood cell type(s) and concentration(s), drug/inhibitory concentration etc., can all be easily controlled. As such, our microsystem provides a method to quantitatively investigate disease processes in which microvascular flow is impaired due to alterations in cell adhesion, aggregation, and deformability, a capability unavailable with existing assays.
Collapse
Affiliation(s)
- David R Myers
- Department of Pediatrics, Emory University School of Medicine, Georgia, USA.
| | | | | | | | | | | | | | | | | |
Collapse
|
61
|
Feghhi S, Sniadecki NJ. Mechanobiology of platelets: techniques to study the role of fluid flow and platelet retraction forces at the micro- and nano-scale. Int J Mol Sci 2011; 12:9009-30. [PMID: 22272117 PMCID: PMC3257114 DOI: 10.3390/ijms12129009] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2011] [Revised: 11/24/2011] [Accepted: 11/28/2011] [Indexed: 12/29/2022] Open
Abstract
Coagulation involves a complex set of events that are important in maintaining hemostasis. Biochemical interactions are classically known to regulate the hemostatic process, but recent evidence has revealed that mechanical interactions between platelets and their surroundings can also play a substantial role. Investigations into platelet mechanobiology have been challenging however, due to the small dimensions of platelets and their glycoprotein receptors. Platelet researchers have recently turned to microfabricated devices to control these physical, nanometer-scale interactions with a higher degree of precision. These approaches have enabled exciting, new insights into the molecular and biomechanical factors that affect platelets in clot formation. In this review, we highlight the new tools used to understand platelet mechanobiology and the roles of adhesion, shear flow, and retraction forces in clot formation.
Collapse
Affiliation(s)
- Shirin Feghhi
- Department of Mechanical Engineering, University of Washington, Stevens Way, Box 352600, Seattle, WA 98195, USA; E-Mail:
| | - Nathan J. Sniadecki
- Department of Mechanical Engineering, University of Washington, Stevens Way, Box 352600, Seattle, WA 98195, USA; E-Mail:
- Department of Bioengineering, University of Washington, 3720 15th Ave NE, Seattle, WA 98105, USA
- Author to whom correspondence should be addressed; E-Mail: ; Tel.: +1-206-685-6591; Fax: +1-206-685-8047
| |
Collapse
|