51
|
Popescu MC, Bita BI, Tucureanu V, Vasilache D, Banu MA, Avram AM, Giurescu-Dumitrescu RA. Superficial and Inner Examination of a Microwave-Irradiated Dental Acrylic Resin and Its Metal-Polymer Interface. MICROSCOPY AND MICROANALYSIS : THE OFFICIAL JOURNAL OF MICROSCOPY SOCIETY OF AMERICA, MICROBEAM ANALYSIS SOCIETY, MICROSCOPICAL SOCIETY OF CANADA 2018; 24:49-59. [PMID: 29485028 DOI: 10.1017/s1431927618000089] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
The aim of this study is to conduct an extended surface and cross-section characterization of a denture base acrylic resin subjected to 500, 650, and 750 W microwave irradiation for 2, 3, and 5 min to assess its morphological modifications. A commercial heat-cured powder was polymerized according to the manufacturer's specifications and distributed into 20 circular samples. A stainless-steel wire was partially embedded in half of the discs, in order to investigate the metal-polymer interface. High-resolution scanning electron microscopy (SEM) imaging, white light interferometry, roughness measurements and Fourier transform infrared spectrometry were employed for morphological and structural evaluation of the irradiated polymer. Superficial adaptation was discovered after 5 min exposure at 500 W, 650 W, and 750 W, revealing significant roughness correction for 750 W. SEM characterization revealed the inner alteration of the resin for the 750 W protocol and a metal-polymer gap developed regardless of the irradiation conditions. The considerable temperature fluctuations that the samples were subject to during the experiments did not essentially change the poly(methyl-methacrylate) bond structure.
Collapse
Affiliation(s)
- Marian C Popescu
- 1Nano-Scale Structuring and Characterization Laboratory,National Institute for Research and Development in Microtechnologies,126A Erou Iancu Nicolae Street,077190 Bucharest,Romania
| | - Bogdan I Bita
- 1Nano-Scale Structuring and Characterization Laboratory,National Institute for Research and Development in Microtechnologies,126A Erou Iancu Nicolae Street,077190 Bucharest,Romania
| | - Vasilica Tucureanu
- 3Laboratory for Micro- and Nanofluidics,National Institute for Research and Development in Microtechnologies,126A Erou Iancu Nicolae Street,077190 Bucharest,Romania
| | - Dan Vasilache
- 5Microwave Circuits and Devices Laboratory,Micromachined Structures,National Institute for Research and Development in Microtechnologies,126A Erou Iancu Nicolae Street,077190 Bucharest,Romania
| | - Melania A Banu
- 6Laboratory of Nanobiotechnology,National Institute for Research and Development in Microtechnologies,126A Erou Iancu Nicolae Street,077190 Bucharest,Romania
| | - Andrei M Avram
- 3Laboratory for Micro- and Nanofluidics,National Institute for Research and Development in Microtechnologies,126A Erou Iancu Nicolae Street,077190 Bucharest,Romania
| | - Raluca A Giurescu-Dumitrescu
- 8Disciplines of Dental Medicine Department, Faculty of Dental Medicine,Titu Maiorescu University,67A Gheorghe Petrascu Street,031593 Bucharest,Romania
| |
Collapse
|
52
|
Gupta P, Ariga P, Deogade SC. Effect of Monopoly-coating Agent on the Surface Roughness of a Tissue Conditioner Subjected to Cleansing and Disinfection: A Contact Profilometric In vitro Study. Contemp Clin Dent 2018; 9:S122-S126. [PMID: 29962776 PMCID: PMC6006873 DOI: 10.4103/ccd.ccd_112_18] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
Introduction Tissue conditioners are used to improve the health of the soft tissues of denture-bearing areas. However, leaching of plasticizers from tissue conditioners results in deterioration, which necessitates frequent replacement. The life of these liners varies, but it can be extended by the use of a coating material. Aim To evaluate the surface roughness of a tissue conditioner with monopoly coating, subjected to denture cleanser and disinfectant. Materials and Methods Sixty disk-shaped specimens of Visco-gel were made and divided into six groups of 10 each (control 1 [C1], control 2 [C2], control 3 [C3], group 1 [M1], group 2 [M2], and group 3 [M3]). Specimens of the control group were not coated with monopoly, while the specimens of the groups 1, 2, and 3 were coated with monopoly. Specimens of C1 and M1 were immersed in distilled water. Specimens of C2, C3, M2, and M3 were immersed into solution of denture cleanser for 8 h at room temperature and immersed in distilled water for the remainder of the 24-h period. C3 and M3 specimens were treated with disinfectant for 10 min before testing the surface roughness. The surface roughness was measured on 1st, 3rd, 5th, 7th, and 14th day, using a contact profilometer. Student's paired t-test was used to compare the mean Ra values within each group. In the present study, P < 0.05 was considered as the level of significance. Results The mean surface roughness values of M1, M2, and M3 groups were less than C1, C2, and C3, respectively. Among all the groups, M1 showed the least surface roughness values. Conclusion Monopoly-coating agent prevents the deterioration and reduces the surface roughness of the tissue conditioner.
Collapse
Affiliation(s)
- Pushkar Gupta
- Department of Prosthodontics and Crown and Bridge, Hitkarini Dental College and Hospital, Jabalpur, Madhya Pradesh, India
| | - Padma Ariga
- Department of Conservative Dentistry and Endodontics, Saveetha Dental College and Hospital, Chennai, Tamil Nadu, India
| | - Suryakant C Deogade
- Department of Prosthodontics and Crown and Bridge, Government Dental College and Hospital, Nagpur, Maharashtra, India
| |
Collapse
|
53
|
Stanković-Pešić J, Kostić M, Igić M, Đorđević V. Biofilm formation on dental materials. ACTA STOMATOLOGICA NAISSI 2018. [DOI: 10.5937/asn1877821p] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/02/2022] Open
|
54
|
da Silva RA, Bernardo LP, Moreno JML, Lara VS, Porto VC. Equisetum giganteum influences the ability of Candida albicans in forming biofilms over the denture acrylic resin surface. PHARMACEUTICAL BIOLOGY 2017; 55:1698-1702. [PMID: 28454505 PMCID: PMC6130476 DOI: 10.1080/13880209.2017.1321024] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
CONTEXT Equisetum giganteum L. (Equisetaceae) is an endemic plant of Central and South America used in traditional medicine. Natural drugs have been frequently used in the treatment of a myriad of diseases, proving to be an alternative to synthetic chemicals, and have been intensively studied in the prevention of sicknesses, including oral diseases. OBJECTIVE This study evaluated the in vitro antiadherent activity of E. giganteum extract against Candida albicans biofilms. MATERIALS AND METHODS Crystal violet and colony-forming units assays were used to quantify the total biofilm biomass and biofilm living cells on a denture base acrylic resin pretreated with hydroethanolic extract of E. giganteum in different concentrations (50, 25, 16, 8, and 4 mg/mL), after 24 h of biofilm development. RESULTS Equisetum giganteum affected biofilms by reduction of biomass and living cells per area of acrylic specimens. The results revealed reduction of 15-44% of the biofilm mass and reduction of numbers of colony-forming units (CFUs) present in biofilms (79%) compared to the untreated control (CTRL/PBS). At all concentrations, it demonstrated important antiadherent activity on Candida albicans biofilms, the main microbe in denture stomatitis. DISCUSSION AND CONCLUSION The present findings show that E. giganteum antimicrobial effects may qualify the extract as a promising natural alternative for topical treatment or prevention of denture stomatitis. The usage of drugs made of natural products shows advantages in relation to synthetic drugs on the market, such as lower cost, lower toxicity, and in relation to the occurrence of microbial resistance.
Collapse
Affiliation(s)
- Rafaela Alves da Silva
- Department of Surgery, Stomatology, Pathology and Radiology, Bauru School of Dentistry, University of São Paulo (USP), Bauru, SP, Brazil
- CONTACT Rafaela Alves da SilvaDepartment of Stomatology (Pathology), Bauru School of Dentistry, University of São Paulo (USP), Alameda Dr. Otávio Pinheiro Brizolla, 9-75, 17012-901, Bauru/SP, Brazil
| | | | | | - Vanessa Soares Lara
- Department of Surgery, Stomatology, Pathology and Radiology, Bauru School of Dentistry, University of São Paulo (USP), Bauru, SP, Brazil
| | - Vinicius Carvalho Porto
- Department of Prosthodontics, Bauru School of Dentistry, University of São Paulo (USP), Bauru, SP, Brazil
| |
Collapse
|
55
|
Cevik P, Yildirim-Bicer AZ. Effect of different types of disinfection solution and aging on the hardness and colour stability of maxillofacial silicone elastomers. Int J Artif Organs 2017; 41:0. [PMID: 29148020 DOI: 10.5301/ijao.5000659] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/18/2017] [Indexed: 11/20/2022]
Abstract
INTRODUCTION Understanding the effect of aging and different disinfecting agents on the physical properties of pigmented maxillofacial silicones may help eliminate the current uncertainty as to the best follow-up suggestions for the patients treated with silicone prostheses. METHODS One hundred fifty specimens (14 × 2 mm) were evaluated for colour and 75 specimens (30 × 10 mm) for hardness (total, 225 specimens). Five specimens were used for hardness testing in each disinfecting solution while 10 silicone specimens were used for colour evaluation. The samples were separated into 5 groups and the initial hardness and colour evaluations were performed and placed in disinfectant solution (neutral soap, effervescent tablet, 0.2% chlorhexidine, 4% chlorhexidine, sodium hypochlorite). A second set of colour and hardness measurements was taken after 48 hours of disinfection and 1,008 hours of artificial aging in a QUV-accelerated weathering tester. Two-way and 1-way analysis of variance with Tukey tests and paired t-test were used for statistical analysis (α = 0.05). RESULTS Before artificial aging, the hardness value of the red pigment group was found to be significantly lower than that of the brown pigment group. After aging, the lowest Shore A value was seen in the neutral soap group, while the highest was seen in the effervescent tablet. CONCLUSIONS Based on the results of this study, chlorohexidine 0.2% was found to be most suitable agent for disinfection of the prostheses. Washing with neutral soap caused loss of pigment from the surface of the silicones. Sodium hypochlorite was found to have a colour-fading effect on silicone specimens.
Collapse
Affiliation(s)
- Pinar Cevik
- Department of Prosthodontics, Faculty of Dentistry, Gazi University, Ankara - Turkey
| | - Arzu Z Yildirim-Bicer
- Department of Prosthodontics, Faculty of Dentistry, Gazi University, Ankara - Turkey
| |
Collapse
|
56
|
Abstract
Objectives: To assess the denture hygiene habits in a population of Lebanese denture wearers. Materials and Methods: One hundred and thirty-two (132) patients [71 women (53.8%) and 61 men (46.2%)] wearing their acrylic dentures for more than two years were included in this study. The hygiene methods related to their dentures were evaluated and the data obtained were analyzed statistically using the IBM® SPSS® statistics 20.0 (USA) statistical package. Results: Regardless of the cleaning technique, the big majority of our participants [123 out of 132 (93.1%)] cleaned their dentures daily. The two mostly used denture cleaning techniques were rinsing with tap water (34.1%) and brushing with toothpaste (31.8%). Nearly half of our patients (45.5%) soaked their dentures during the night; most of them with cleansing tablets dissolved in water (28.8%). Conclusions: Within the limitations of our study, it was concluded that in a sample of Lebanese population surveyed about denture hygiene habits, the daily frequency of denture cleaning is satisfactory, but the techniques and products used were self-estimated and, consequently, not sufficient.
Collapse
Affiliation(s)
- Georges Aoun
- Department of Oral Pathology and Diagnosis, Faculty of Dental Medicine, Lebanese University, Beirut, Lebanon
| | - Elie Gerges
- Department of Prosthodontics, Faculty of Dental Medicine, Lebanese University, Beirut, Lebanon
| |
Collapse
|
57
|
Köroğlu A, Şahin O, Dede DÖ, Deniz ŞT, Karacan Sever N, Özkan S. Efficacy of denture cleaners on the surface roughness and Candida albicans adherence of sealant agent coupled denture base materials. Dent Mater J 2017; 35:810-816. [PMID: 27725519 DOI: 10.4012/dmj.2016-103] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
This study investigated the effect of denture cleansers on the surface roughness and Candida albicans adherence of surface sealant agent coupled denture base resins. One hundred and twenty specimens were fabricated from 2 polymethyl methacrylate (PMMA) (Meliodent; Acron MC) and 1 polyamide (Deflex) denture base materials, coated with a sealant agent (Palaseal) and divided into 4 groups (n=10) according to overnight cleaning procedures: distilled water (control), 5% sodium hypochlorite (NaOCl) and two different sodium perborate (Corega; Rapident). The surface roughness values were measured with a profilometer before (Ra0) and after 90 days immersion in denture cleaners (Ra1). Specimens were incubated with Candida albicans suspension and Candida colony- forming units (CFU) (Cfu/mm) were counted. Significant differences were found, between the Ra0 and Ra1 values of 5% NaOCl applied Acron MC, Deflex and also Rapident applied Deflex groups (p<0.05). Denture cleaning procedures had no significant effects on the quantitiy of Candida albicans.
Collapse
Affiliation(s)
- Ayşegül Köroğlu
- Department of Prosthodontics, Faculty of Dentistry, Bulent Ecevit University
| | | | | | | | | | | |
Collapse
|
58
|
Gautam N, Sharma A, Bashir U, Rapolu S, Mamatha N, Sravani S. Effect of Different Dentifrices on the Surface Roughness of Acrylic Resins: An in vitro Study. J Contemp Dent Pract 2017; 18:679-682. [PMID: 28816189 DOI: 10.5005/jp-journals-10024-2106] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
AIM This study was undertaken to study the effect of three most commonly used dentifrices for denture cleaning and to find out any positive association between number of strokes by toothbrush and surface roughness of acrylic resin. MATERIALS AND METHODS About 40 acrylic rectangular blocks with high finish were polished until surface roughness was calculated as 0 pirn. The materials tested were distilled water as a control group, Patanjali Dant Kanti, Colgate Total Cream, and Cleansodent as dentifrices. Stroking was done with dentifrices, and surface roughness readings were recorded at 1,000, 9,000, and 18,000 strokes. RESULTS Patanjali Dant Kanti was found to have maximum abrasive potential followed by Colgate Total Cream, followed by Cleansodent and least by distilled water. CONCLUSION Surface roughness was found to be directly proportional to the type, size, and fineness of the abrasive component used; the professional denture cleanser (Cleansodent) has less abrasive potential than the regular toothpastes. Among those tested, the highest abrasive potential was found in Patanjali Dant Kanti and lowest by Cleansodent (denture cleanser). CLINICAL SIGNIFICANCE The patient as well as dentist should choose the dentifrice with utmost care noting the size and type of abrasives used. Washing the dentures normally with water without toothbrush daily and cleaning of dentures once in 10 to 15 days with a soft toothbrush and professional denture cleanser should be the line of maintenance of dentures.
Collapse
Affiliation(s)
- Nitin Gautam
- Department of Prosthodontics, Indira Gandhi Government Dental College & Hospital, Jammu, Jammu and Kashmir, India, e-mail:
| | - Aditi Sharma
- Department of Prosthodontics, Indira Gandhi Government Dental College & Hospital, Jammu, Jammu and Kashmir, India
| | - Unjum Bashir
- Department of Prosthodontics, Government Dental College Srinagar, Jammu and Kashmir, India
| | - Sisir Rapolu
- Department of Prosthodontics, MNR Dental College & Hospital, Sangareddy, Telangana, India
| | - Nallamilli Mamatha
- Department of Prosthodontics, MNR Dental College & Hospital, Sangareddy, Telangana, India
| | - Siripurapu Sravani
- Department of Prosthodontics, MNR Dental College & Hospital, Sangareddy, Telangana, India
| |
Collapse
|
59
|
Mishra SK, Chowdhary R, Kumari S. Microleakage at the Different Implant Abutment Interface: A Systematic Review. J Clin Diagn Res 2017; 11:ZE10-ZE15. [PMID: 28764310 DOI: 10.7860/jcdr/2017/28951.10054] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2017] [Accepted: 05/20/2017] [Indexed: 12/21/2022]
Abstract
INTRODUCTION Presence of gap at the implant-abutment interface, leads to microleakage and accumulation of bacteria which can affect the success of dental implants. AIM To evaluate the sealing capability of different implant connections against microleakage. MATERIALS AND METHODS In January 2017 an electronic search of literature was performed, in Medline, EBSCO host and Pubmed data base. The search was focused on ability of different implant connections in preventing microleakage. The related titles and abstracts available in English were screened, and the articles that fulfilled the inclusion criteria were selected for full text reading. RESULTS In this systematic review, literature search initially resulted in 78 articles among which 30 articles only fulfilled the criteria for inclusion and were finally included in the review. Almost all the studies showed that there was some amount of microleakage at abutment implant interface. Microleakage was very less in Morse taper implants in comparison to other implant connections. Majority of studies showed less microleakage in static loading conditions and microleakage increases in dynamic loading conditions. CONCLUSION In this systematic review maximum studies showed that there was some amount of microleakage at abutment implant interface. External hexagon implants failed completely to prevent microleakage in both static and dynamic loading conditions of implants. Internal hexagon implants mainly internal conical (Morse taper) implants are very promising in case of static loading and also showed less microleakage in dynamic loading conditions. Torque recommended by manufacturer should be followed strictly to get a better seal at abutment implant interface. Zirconia abutments are more to microleakage than Titanium abutments and there use should be discouraged. Zirconia abutments should be only restricted to cases where there was very high demand of aesthetics.
Collapse
Affiliation(s)
- Sunil Kumar Mishra
- Reader, Department of Maxillofacial Prosthodontics and Implantology, Peoples College of Dental Sciences and Research Centre, Bhopal, Madhya Pradesh, India
| | - Ramesh Chowdhary
- Professor, Department of Maxillofacial Prosthodontics and Implantology, Rajarajeswari Dental College and Hospital, Bangalore, Karnataka, India
| | - Shail Kumari
- Postgraduate Student, Department of Orthodontics and Dentofacial Orthopaedics, Rishiraj College of Dental Sciences and Research Centre, Bhopal, Madhya Pradesh, India
| |
Collapse
|
60
|
Karakis D, Akay C, Oncul B, Rad AY, Dogan A. Effectiveness of disinfectants on the adherence of Candida albicans to denture base resins with different surface textures. J Oral Sci 2017; 58:431-7. [PMID: 27665984 DOI: 10.2334/josnusd.15-0642] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022]
Abstract
The aim of the present study was to compare the effects of some disinfectants, including ethanol extract of propolis (EEP), on the adhesion of Candida albicans to denture base resins. Seventy-two acrylic resin samples were prepared, half of which was polished and the other half was roughened. C. albicans strain ATCC 10231 was incubated on Sabouraud dextrose agar (SDA) at 37°C for 48 h. The adhesion period was completed by keeping the cells in this suspension for 90 min at 37°C. Specimens were then immersed in the following solutions: 1%, 2%, and 5% sodium hypochlorite; 4% chlorhexidine gluconate; and 10% EEP. Quantification of the antifungal activity of the chemical solutions was performed using the colorimetric MTT (3-[4,5-dimethylthiazol-2-yl]-2,5-diphenyltetrazolium bromide) assay test. One-way ANOVA and post-hoc Tukey tests were performed to evaluate the effectiveness of chemical agents. Polished and roughened surfaces were compared using independent sample t-test. The mean surface roughness value was 0.35 (±0.04) µm for the polished group and 1.2 (±0.2) µm for the roughened group. The contact angles of both surfaces showed statistically significant difference, and 10% EEP solution exhibited significantly less removal of adherent viable C. albicans cells in both groups. All forms of sodium hypochlorite solutions yielded higher efficiency than 4% chlorhexidine gluconate and EEP solutions (P < 0.05). (J Oral Sci 58, 431-437, 2016).
Collapse
Affiliation(s)
- Duygu Karakis
- Department of Prosthetic Dentistry, Faculty of Dentistry, University of Gazi
| | | | | | | | | |
Collapse
|
61
|
Effects of trimethylsilane plasma coating on the hydrophobicity of denture base resin and adhesion of Candida albicans on resin surfaces. J Prosthet Dent 2017; 118:765-770. [PMID: 28434686 DOI: 10.1016/j.prosdent.2017.01.003] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2016] [Revised: 01/03/2017] [Accepted: 01/04/2017] [Indexed: 11/24/2022]
Abstract
STATEMENT OF PROBLEM Candida-associated denture stomatitis is the most common oral mucosal lesion among denture wearers. Trimethylsilane (TMS) plasma coating may inhibit the growth of Candida albicans on denture surfaces. PURPOSE The purpose of this in vitro study was to investigate whether TMS plasma coatings can effectively reduce C albicans adhesion on denture base acrylic resin surfaces. MATERIAL AND METHODS Sixty denture base acrylic resin disks with smooth and rough surfaces were prepared and were either left untreated (control group) or coated with TMS monomer (experimental group) by using plasma. Contact angles were measured immediately after TMS plasma coating. The morphology of C albicans adhesion was observed with scanning electron microscopy (SEM). Energy-dispersive spectroscopy (EDS) was used to characterize the elemental composition of the specimen surface. An adhesion test was performed by incubating the resin disk specimens in C albicans suspensions (1×107 cells/mL) at 37°C for 24 hours and further measuring the optical density of the C albicans by using a 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) assay test. One-way ANOVA and 2-way ANOVA were followed by a post hoc test analysis (α=.05). RESULTS The group with TMS coating exhibited a more hydrophobic surface than the control group. EDS analysis revealed successful TMS plasma coating. The difference in the mean contact angles between the uncoated group and the TMS-coated group was statistically significant (P<.05), 79.0 ±2.9 degrees versus 105.7 ±1.5 degrees for the smooth surface and 90.2 ±7.6 degrees versus 131.5 ±2.1 degrees for the rough surface. In SEM analysis, the C albicans biofilm was found to grow more on the surface of the denture base resin without the TMS coating than on the surfaces of the experimental group. In the adhesion test, the amount of C albicans adhering to the surface of denture base resin with the TMS coating was significantly less than that on the surfaces without TMS coating (P<.05). CONCLUSIONS TMS coating significantly reduced the adhesion of C albicans to the denture base resin and may reduce denture stomatitis.
Collapse
|
62
|
Chen H, Han Q, Zhou X, Zhang K, Wang S, Xu HHK, Weir MD, Feng M, Li M, Peng X, Ren B, Cheng L. Heat-Polymerized Resin Containing Dimethylaminododecyl Methacrylate Inhibits Candida albicans Biofilm. MATERIALS 2017; 10:ma10040431. [PMID: 28772791 PMCID: PMC5507000 DOI: 10.3390/ma10040431] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/29/2016] [Revised: 04/14/2017] [Accepted: 04/14/2017] [Indexed: 02/05/2023]
Abstract
The prevalence of stomatitis, especially caused by Candida albicans, has highlighted the need of new antifungal denture materials. This study aimed to develop an antifungal heat-curing resin containing quaternary ammonium monomer (dimethylaminododecyl methacrylate, DMADDM), and evaluate its physical performance and antifungal properties. The discs were prepared by incorporating DMADDM into the polymer liquid of a methyl methacrylate-based, heat-polymerizing resin at 0% (control), 5%, 10%, and 20% (w/w). Flexure strength, bond quality, surface charge density, and surface roughness were measured to evaluate the physical properties of resin. The specimens were incubated with C. albicans solution in medium to form biofilms. Then Colony-Forming Units, XTT assay, and scanning electron microscope were used to evaluate antifungal effect of DMADDM-modified resin. DMADDM modified acrylic resin had no effect on the flexural strength, bond quality, and surface roughness, but it increased the surface charge density significantly. Meanwhile, this new resin inhibited the C. albicans biofilm significantly according to the XTT assay and CFU counting. The hyphae in C. albicans biofilm also reduced in DMADDM-containing groups observed by SEM. DMADDM modified acrylic resin was effective in the inhibition of C. albicans biofilm with good physical properties.
Collapse
Affiliation(s)
- Hui Chen
- State Key Laboratory of Oral Diseases, Sichuan University, Chengdu 610041, China.
- Department of Operative Dentistry and Endodontics, West China Hospital of Stomatology, Sichuan University, Chengdu 610041, China.
- Department of Preventive Dentistry, Stomatological Hospital of Chongqing Medical University, Chongqing 401147, China.
| | - Qi Han
- State Key Laboratory of Oral Diseases, Sichuan University, Chengdu 610041, China.
| | - Xuedong Zhou
- State Key Laboratory of Oral Diseases, Sichuan University, Chengdu 610041, China.
- Department of Operative Dentistry and Endodontics, West China Hospital of Stomatology, Sichuan University, Chengdu 610041, China.
| | - Keke Zhang
- State Key Laboratory of Oral Diseases, Sichuan University, Chengdu 610041, China.
| | - Suping Wang
- State Key Laboratory of Oral Diseases, Sichuan University, Chengdu 610041, China.
- Department of Operative Dentistry and Endodontics, West China Hospital of Stomatology, Sichuan University, Chengdu 610041, China.
| | - Hockin H K Xu
- Biomaterials & Tissue Engineering Division, Department of Endodontics, Prosthodontics and Operative Dentistry, University of Maryland Dental School, Baltimore, MD 21201, USA.
| | - Michael D Weir
- Biomaterials & Tissue Engineering Division, Department of Endodontics, Prosthodontics and Operative Dentistry, University of Maryland Dental School, Baltimore, MD 21201, USA.
| | - Mingye Feng
- State Key Laboratory of Oral Diseases, Sichuan University, Chengdu 610041, China.
| | - Mingyun Li
- State Key Laboratory of Oral Diseases, Sichuan University, Chengdu 610041, China.
| | - Xian Peng
- State Key Laboratory of Oral Diseases, Sichuan University, Chengdu 610041, China.
| | - Biao Ren
- State Key Laboratory of Oral Diseases, Sichuan University, Chengdu 610041, China.
| | - Lei Cheng
- State Key Laboratory of Oral Diseases, Sichuan University, Chengdu 610041, China.
- Department of Operative Dentistry and Endodontics, West China Hospital of Stomatology, Sichuan University, Chengdu 610041, China.
| |
Collapse
|
63
|
Buijssen KJDA, Oosterhof JJH, Basil L, Waters M, Duits MA, Busscher HJ, van der Mei HC, van der Laan BFAM. Influence of surface roughness on silicone rubber voice prostheses on in vitro biofilm formation and clinical lifetime in laryngectomised patients. Clin Otolaryngol 2017; 42:1235-1240. [PMID: 28236355 DOI: 10.1111/coa.12856] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 02/18/2017] [Indexed: 12/01/2022]
Abstract
OBJECTIVES Evaluation of the influence of a smooth surface moulding technique of silicone rubber indwelling voice prostheses on in vitro biofilm formation and analysis of the clinical in situ lifetime. DESIGN Biofilm formation on smooth and Groningen ultra low resistance (URL) prostheses was studied in an artificial throat model. The clinical lifetime of smooth voice prostheses was compared to the previous lifetime of URL by counting the number of replacements in a consecutive 6-month period in the same patient. PARTICIPANTS Eleven laryngectomised patients in follow-up who required frequent replacement of their voice prostheses. SETTINGS Tertiary University Medical Center. RESULTS Use of a smoother mould and less viscous silicone rubber yielded a decrease in surface roughness from 46 to 8 nm and was accompanied by a 40% reduction in the prevalence of bacteria and yeast in in vitro formed biofilms. Clinically, the lifetime was significantly (P<.005) increased by a factor of 2.1. CONCLUSIONS This combined in vitro and clinical study suggests that the choice of material and in particular its surface finishing may be determining factors with respect to the clinical lifetime of silicone rubber implants and devices failing due to biofilm formation.
Collapse
Affiliation(s)
- K J D A Buijssen
- Department of Otorhinolaryngology-Head and Neck Surgery, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands.,Department of Biomedical Engineering, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands.,Department of Otorhinolaryngology, Albert Schweitzer Hospital, Dordrecht, The Netherlands
| | - J J H Oosterhof
- Department of Otorhinolaryngology-Head and Neck Surgery, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
| | - L Basil
- Principality Medical Ltd., Newport, UK
| | - M Waters
- Principality Medical Ltd., Newport, UK
| | - M A Duits
- Department of Otorhinolaryngology-Head and Neck Surgery, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
| | - H J Busscher
- Department of Biomedical Engineering, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
| | - H C van der Mei
- Department of Biomedical Engineering, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
| | - B F A M van der Laan
- Department of Otorhinolaryngology-Head and Neck Surgery, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
| |
Collapse
|
64
|
Tomičić R, Tomičić Z, Raspor P. Adhesion of Candida spp. and Pichia spp. to Wooden Surfaces. Food Technol Biotechnol 2017; 55:138-142. [PMID: 28559743 PMCID: PMC5434367 DOI: 10.17113/ftb.55.01.17.4514] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2015] [Accepted: 11/23/2016] [Indexed: 11/12/2022] Open
Abstract
Yeast adhesion to and biofilm formation on surfaces is present in many different environments. In food industry, biofilms may be a source of contaminations, causing food spoilage and reducing quality of products. Candida and Pichia are two common yeast genera involved in the spoilage of some food products. The aim of this study is to assess the potential of Candida and Pichia species to adhere to two types of wooden surfaces (smooth and rough), one of the materials typical for the food processing industry, and investigate the influence of surface roughness of wood on the degree of yeast adhesion. The adhesion of the cells to the wooden surfaces was determined by rinsing them from the surface, followed by methylene blue staining, and quantification after imaging under microscope by automatic counting of viable cells. The results showed that all Candida and Pichia strains were able to adhere to the wooden surfaces in a species- and strain-dependent manner. On the other hand, our data indicated that adhesion by these yeasts was not significantly affected by the roughness of the wood surfaces.
Collapse
Affiliation(s)
- Ružica Tomičić
- Faculty of Technology, University of Novi Sad, Bulevar cara Lazara 1, RS-21000 Novi Sad, Serbia
| | - Zorica Tomičić
- Institute of Food Technology, University of Novi Sad, Bulevar cara Lazara 1, RS-21000 Novi Sad, Serbia
| | - Peter Raspor
- Biotechnical Faculty, University of Ljubljana, Jamnikarjeva 101, SI-1000 Ljubljana, Slovenia
| |
Collapse
|
65
|
Tomičić R, Raspor P. Influence of growth conditions on adhesion of yeast Candida spp. and Pichia spp. to stainless steel surfaces. Food Microbiol 2017; 65:179-184. [PMID: 28400000 DOI: 10.1016/j.fm.2017.02.008] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2016] [Revised: 02/23/2017] [Accepted: 02/24/2017] [Indexed: 11/27/2022]
Abstract
An understanding of adhesion behavior of Candida and Pichia yeast under different environmental conditions is key to the development of effective preventive measures against biofilm-associated infection. Hence in this study we investigated the impact of growth medium and temperature on Candida and Pichia adherence using stainless steel (AISI 304) discs with different degrees of surface roughness (Ra = 25.20-961.9 nm), material typical for the food processing industry as well as medical devices. The adhesion of the yeast strains to stainless steel surfaces grown in Malt Extract broth (MEB) or YPD broth at three temperatures (7 °C, 37 °C, 43 °C for Candida strains and 7 °C, 27 °C, 32 °C for Pichia strains) was assessed by crystal violet staining. The results showed that the nutrient content of medium significantly influenced the quantity of adhered cells by the tested yeasts. Adhesion of C. albicans and C. glabrata on stainless steel surfaces were significantly higher in MEB, whereas for C. parapsilosis and C. krusei it was YPD broth. In the case with P. pijperi and P. membranifaciens, YPD broth was more effective in promoting adhesion than MEB. On the other hand, our data indicated that temperature is a very important factor which considerably affects the adhesion of these yeast. There was also significant difference in cell adhesion on all types of stainless steel surfaces for all tested yeast.
Collapse
Affiliation(s)
- Ružica Tomičić
- Faculty of Technology, University of Novi Sad, Bulevar cara Lazara 1, 21000, Novi Sad, Serbia.
| | - Peter Raspor
- Biotechnical Faculty, University of Ljubljana, Jamnikarjeva 101, 1000, Ljubljana, Slovenia.
| |
Collapse
|
66
|
Khalaf S, Ariffin Z, Husein A, Reza F. Surface Coating of Gypsum-Based Molds for Maxillofacial Prosthetic Silicone Elastomeric Material: Evaluating Different Microbial Adhesion. J Prosthodont 2017; 26:664-669. [PMID: 28177575 DOI: 10.1111/jopr.12460] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/30/2015] [Indexed: 11/30/2022] Open
Abstract
PURPOSE To compare the adhesion of three microorganisms on modified and unmodified silicone elastomer surfaces with different surface roughnesses and porosities. MATERIALS AND METHODS Candida albicans, Streptococcus mutans, and Staphylococcus aureus were incubated with modified and unmodified silicone groups (N = 35) for 30 days at 37°C. The counts of viable microorganisms in the accumulating biofilm layer were determined and converted to cfu/cm2 unit surface area. A scanning electron microscope (SEM) was used to evaluate the microbial adhesion. Statistical analysis was performed using t-test, one-way ANOVA, and post hoc tests as indicated. RESULTS Significant differences in microbial adhesion were observed between modified and unmodified silicone elastomers after the cells were incubated for 30 days (p < 0.001). SEM showed evident differences in microbial adhesion on modified silicone elastomer compared with unmodified silicone elastomer. CONCLUSIONS Surface modification of silicone elastomer yielding a smoother and less porous surface showed lower adhesion of different microorganisms than observed on unmodified surfaces.
Collapse
Affiliation(s)
- Salah Khalaf
- Prosthodontics Unit, Faculty of Dentistry, Universiti Sains Malaysia, Kelantan, Malaysia.,Prosthodontics Unit, Faculty of Dentistry, University of Anbar, Anbar, Iraq
| | - Zaihan Ariffin
- Prosthodontics Unit, Faculty of Dentistry, Universiti Sains Malaysia, Kelantan, Malaysia
| | - Adam Husein
- Prosthodontics Unit, Faculty of Dentistry, Universiti Sains Malaysia, Kelantan, Malaysia
| | - Fazal Reza
- Prosthodontics Unit, Faculty of Dentistry, Universiti Sains Malaysia, Kelantan, Malaysia
| |
Collapse
|
67
|
Sushma R, Sathe TT, Farias A, Sanyal PK, Kiran S. "Nature cures:" An alternative herbal formulation as a denture cleanser. Ann Afr Med 2017; 16:6-12. [PMID: 28300045 PMCID: PMC5452698 DOI: 10.4103/aam.aam_43_16] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
BACKGROUND Candida albicans is one of the microorganisms which harbor the oral cavity, especially in elderly. However, the incidence of existence of this increases in patients using removable dental prosthesis. There is therefore a need to test the anticandidal efficacy of these cost-effective, easily available products to be used as routine denture cleansers. AIM AND OBJECTIVES (1) To evaluate antifungal properties of triphala churna on the heat cure denture base material. (2) To evaluate the antifungal effect of chlorhexidine gluconate on the heat cure denture base material. (3) To compare the antifungal effect of triphala churna and chlorhexidine gluconate with a control. (4) To evaluate which among triphala churna and chlorhexidine gluconate has a better antifungal property on the heat cure denture base material. MATERIALS AND METHODS Study population consisted of sixty dentures wearers from those attending the Outpatient Department of Prosthodontics of the School of Dentistry, Krishna Institute of Medical Sciences Deemed University, Karad. Swabs were collected from the dentures before and after the use of triphala and chlorhexidine. The swabs were cultured on Sabouraud dextrose agar and the total Candida counts were determined. CONCLUSION Triphala as an antifungal is shown to have more efficacy than the conventional chlorhexidine mouthwash. Résumé Arrière-plan: Candida albicans est l'un des micro-organismes qui abritent la cavité buccale surtout chez les personnes âgées. Cependant, l'incidence de l'existence de cette augmentation chez les patients utilisant des prothèses dentaires amovibles. Il est donc nécessaire de tester l'efficacité anticancédique de ces produits rentables et faciles à utiliser pour être utilisés comme nettoyants de routine pour prothèses dentaires. Buts et Objectifs: (1) Évaluer les propriétés antifongiques de Triphala churna sur le matériau de base de la prothèse thermo-durcissable. (2) Évaluer l'effet antifongique du gluconate de chlorhexidine sur le matériau de base de la prothèse thermo-durcissable. (3) Comparer l'effet antifongique de Triphala churna et du gluconate de chlorhexidine avec un témoin. (4) Évaluer lequel parmi Triphala churna et le gluconate de chlorhexidine a une meilleure propriété antifongique sur le matériel de base de la prothèse de durcissement à chaud. Matériaux et Méthode: La population de l'étude était constituée de soixante porteurs de prothèses dentaires de ceux qui fréquentaient le Département de Prosthodontie de l'École des Sciences Dentaires de l'Institut Krishna des Sciences Médicales de l'Université de Karad. Des prélèvements ont été effectués sur les prothèses avant et après l'utilisation de Triphala et de chlorhexidine. On a cultivé les écouvillons sur de l'agar Sabouraud dextrose et on a déterminé le nombre total de candida. CONCLUSION Triphala comme un anti fongique est démontré pour avoir plus d'efficacité que le lavage de la bouche classique chlorhexidine.
Collapse
Affiliation(s)
- R. Sushma
- Department of Prosthodontics and Crown and Bridge, School of Dental Sciences, Krishna Institute of Medical Sciences and Deemed University, Karad, Maharashtra, India
| | - Tanuja Tanaji Sathe
- Department of Prosthodontics and Crown and Bridge, School of Dental Sciences, Krishna Institute of Medical Sciences and Deemed University, Karad, Maharashtra, India
| | - Anand Farias
- Department of Prosthodontics and Crown and Bridge, Melaka-Manipal Medical College, Melaka, Malaysia
| | - Pronob Kumar Sanyal
- Department of Prosthodontics and Crown and Bridge, School of Dental Sciences, Krishna Institute of Medical Sciences and Deemed University, Karad, Maharashtra, India
| | - Shashi Kiran
- Department of Pedodontics and Preventive Dentistry, School of Dental Sciences, Krishna Institute of Medical Sciences and Deemed University, Karad, Maharashtra, India
| |
Collapse
|
68
|
Krishnamurthy S, Hallikerimath RB. An In-vitro Evaluation of Retention, Colonization and Penetration of Commonly Used Denture Lining Materials By Candida albicans. J Clin Diagn Res 2016; 10:ZC84-ZC88. [PMID: 27891466 DOI: 10.7860/jcdr/2016/20892.8665] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2016] [Accepted: 07/13/2016] [Indexed: 11/24/2022]
Abstract
INTRODUCTION Colonization of the surface by Candida albicans and related Candida species is one of the major concerns of denture lining materials. AIM We evaluated retention, colonization and penetration of the four denture lining materials namely Molloplast B, Permaflex, GC Soft Liner and Ufi Gel Hard C by Candida albicans. MATERIAL AND METHODS a) Evaluation of retention: Five test discs of each material with smooth surface on one side and rough on the other were prepared and surface roughness (Ra) was measured with profilometer. Retention of C. albicans to discs was monitored after one hour of incubation (37°C) with standardized (2.8 x 106 cfu/ml) washed cell suspension. Discs were stained with acridine orange and attached cells were counted using inverted microscope; b) Evaluation of colonization and penetration: Eight test discs of each material in sterile artificial saliva, were inoculated with C. albicans and incubated for six weeks. Two sections were cut across each test disc to provide three replicate samples. Candida cells on cut disc sections were fixed, dehydrated, air dried and viewed via fluorescence microscope; c) Evaluation of antifungal action: Two test discs of each material were placed onto diagnostic sensitivity testing the agar plate. After incubation at 37°C for 24 hours, the zone of inhibition formed around the samples were measured at four places, and the mean calculated. RESULTS a) All rough surfaces showed higher retention of C. albicans than smooth surfaces. Among the smooth surfaces, Molloplast B and GC Soft Liner showed highest and lowest retention of C. albicans respectively (p=0.0090). Among the rough surfaces, the variation in the retention of C. albicans was not statistically significant; b) Penetration of C. albicans was observed through all three sections of the test discs of each material. There was no statistically significant difference among the test materials; c) Molloplast B and Permaflex produced a mean zone of inhibition of 16.9±4.8mm and 14.80±3.8mm respectively. CONCLUSION a) Smoother surfaces retain fewer cells than rough surfaces; b) Denture lining materials permit infiltration of Candida through their structure; c) Denture lining materials have insignificant anti-fungal properties.
Collapse
Affiliation(s)
- Sushma Krishnamurthy
- Senior Lecturer, Deparment of Prosthodontics and Crown and Bridge, Maratha Mandal's NGH Institute of Dental Sciences and Research Centre , Belgaum, Karnataka, India
| | - Rajendra B Hallikerimath
- Professor and Head, Deparment of Prosthodontics and Crown and Bridge, Maratha Mandal's NGH Institute of Dental Sciences and Research Centre , Belgaum, Karnataka, India
| |
Collapse
|
69
|
The influence of cyclic stress on surface properties of soft liners. Odontology 2016; 105:214-221. [PMID: 27456685 DOI: 10.1007/s10266-016-0260-7] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2015] [Accepted: 06/20/2016] [Indexed: 10/21/2022]
Abstract
Soft polymers used under tissue-supported prostheses have limited service life because of surface degradation. PURPOSE This paper evaluates the changes in surface properties and softness of soft relining materials after cyclic loading in water. MATERIALS AND METHODS 3 polysiloxane (Silagum AM Comfort, Molloplast B, Mollosil Plus) and 2 acrylic-based (Vertex Soft, Astron LC Soft) proprietary soft relining materials and a vinyl polysiloxane (Imprint 2 Garant) as the reference impression material evaluated. A stainless steel block for detail reproduction was used on the basis of the apparatus recommended by the ISO 4823:1992 test method for preparing a standardized surface. A control group from each material was only subjected to water immersion. Non-destructive cyclic loading was carried out with a strain of 16.6 % and a frequency of 1.6 Hz 200,000 times in distilled water at 37 °C. The specimens were then duplicated and compared with the controls using roughness measurements, detail reproduction and Scanning Electron Microscope. Shore A hardness values before and after cycling were also measured. RESULTS After degradation in the form of mechanical cycling in water, loss of substance and loss of surface detail was observed. Surface properties and Shore A hardness values of acrylic-based soft liners changed significantly (p < 0.05). CONCLUSIONS The chemical composition of the soft relining materials seemed to affect their potential of preserving the surface texture and softness after mechanical cycling. Mechanical cycling influences the surface degradation process leading to changes of the surface texture. Polysiloxane-based materials preserved their softness, surface texture and surface smoothness better under cyclic loading compared to acrylic resin -based plasticized materials.
Collapse
|
70
|
Darwish M, Nassani MZ. Evaluation of the effect of denture adhesives on surface roughness of two chemically different denture base resins. Eur J Dent 2016; 10:321-326. [PMID: 27403047 PMCID: PMC4926582 DOI: 10.4103/1305-7456.184155] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
Abstract
Objective: To evaluate the effect of four commercially available denture adhesives (DAs) on surface roughness of two chemically different denture base materials. Materials and Methods: Fifty specimens of heat-cured polymethyl methacrylate, and another fifty specimens of light-cured urethane dimethacrylate were divided into five groups (n = 10), each was immersed in four prepared DAs (Corega Super Cream, Corega Ultra Powder, Olivafix Cream, Protefix Cream) as well as distilled water (control group). The mean surface roughness (Ra) of the polished and unpolished surfaces of the specimens was recorded using profilometer device. T-test for paired observation was used to indicate any changes in surface roughness between the baseline and after 30 days of immersion in the DA. Results: Almost all the tested DAs had no significant effect on the roughness of polished and unpolished surfaces of both denture base materials. The Corega super cream DA produced significant increase in the roughness of the polished surfaces of both types of acrylic specimens (P < 0.05). Conclusion: The majority of the investigated DAs appears not to affect the surface roughness of denture base materials. Only Corega super cream DA produced detectable increase in the roughness of polished surfaces of denture base specimens.
Collapse
Affiliation(s)
- Mahmoud Darwish
- Department of Prosthetic Dental Sciences, Al-Farabi Colleges, Riyadh, Saudi Arabia.,Department of Prosthodontics, Faculty of Dentistry, Suez Canal University, Ismailia, Egypt
| | - Mohammad Zakaria Nassani
- Department of Prosthetic Dental Sciences, Al-Farabi Colleges, Riyadh, Saudi Arabia.,Department of Removable Prosthodontics, Faculty of Dentistry, University of Aleppo, Aleppo, Syria
| |
Collapse
|
71
|
Abdallah RM. Evaluation of polymethyl methacrylate resin mechanical properties with incorporated halloysite nanotubes. J Adv Prosthodont 2016; 8:167-71. [PMID: 27350849 PMCID: PMC4919485 DOI: 10.4047/jap.2016.8.3.167] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2015] [Revised: 12/02/2015] [Accepted: 01/12/2016] [Indexed: 11/25/2022] Open
Abstract
PURPOSE This study inspects the effect of incorporating halloysite nanotubes (HNTs) into polymethyl methacrylate (PMMA) resin on its flexural strength, hardness, and Young's modulus. MATERIALS AND METHODS Four groups of acrylic resin powder were prepared. One group without HNTs was used as a control group and the other three groups contained 0.3, 0.6 and 0.9 wt% HNTs. For each one, flexural strength, Young's modulus and hardness values were measured. One-way ANOVA and Tukey's test were used for comparison (P<.05). RESULTS At lower concentration (0.3 wt%) of HNT, there was a significant increase of hardness values but no significant increase in both flexural strength and Young's modulus values of PMMA resin. In contrast, at higher concentration (0.6 and 0.9 wt%), there was a significant decrease in hardness values but no significant decrease in flexural strength and Young's modulus values compared to those of the control group. CONCLUSION Addition of lower concentration of halloysite nanotubes to denture base materials could improve some of their mechanical properties. Improving the mechanical properties of acrylic resin base material could increase the patient satisfaction.
Collapse
Affiliation(s)
- Reham M Abdallah
- Dental Biomaterials Department, Faculty of Dentistry, Mansoura University, Mansoura, Egypt
| |
Collapse
|
72
|
Muscat Y, Farrugia C, Camilleri L, Arias-Moliz MT, Valdramidis V, Camilleri J. Investigation of Acrylic Resin Disinfection Using Chemicals and Ultrasound. J Prosthodont 2016; 27:461-468. [DOI: 10.1111/jopr.12511] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/06/2016] [Indexed: 11/27/2022] Open
Affiliation(s)
- Ylainia Muscat
- Department of Restorative Dentistry, Faculty of Dental Surgery; University of Malta; Malta
| | - Cher Farrugia
- Department of Restorative Dentistry, Faculty of Dental Surgery; University of Malta; Malta
| | - Liberato Camilleri
- Department of Statistics and Operations Research; Faculty of Science; University of Malta; Malta
| | - Maria Teresa Arias-Moliz
- Department of Microbiology, Faculty of Dentistry; University of Granada; Campus Cartuja Granada Spain
| | - Vasilis Valdramidis
- Department of Food Studies & Environmental Health, Faculty of Health Sciences; University of Malta; Malta
| | - Josette Camilleri
- Department of Restorative Dentistry, Faculty of Dental Surgery; University of Malta; Malta
| |
Collapse
|
73
|
Prakash B, Shekar M, Maiti B, Karunasagar I, Padiyath S. Prevalence of Candida spp. among healthy denture and nondenture wearers with respect to hygiene and age. J Indian Prosthodont Soc 2016; 15:29-32. [PMID: 26929483 PMCID: PMC4762283 DOI: 10.4103/0972-4052.155041] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
Dentures are inert and nonshading surfaces and therefore get easily colonized by Candida species. Subsequent biofilm produced by them lead to denture stomatitis and candidiasis. This study was aimed to understand the prevalence of Candida species among healthy denture and nondenture wearers with respect to their age and hygiene status. Swabs were collected from 50 complete dentures and 50 non-denture wearers and processed on Sabouraud's dextrose agar. Identification of Candida species was done by staining and a battery of biochemical tests. Data obtained was correlated with age & oral hygiene and statistical analysis was performed. Candida was isolated from both denture and nondenture wearers. Prevalence of different Candida species was significantly higher in denture wearers and found predominated by C. albicans, C. tropicalis, C. dubliensis and C. glabrata. Among nondenture wearers, C. albicans and C. tropicalis were isolated. Prevalence of Candida increased with increasing age among denture wearers. Men presented declining denture hygiene compared to women with increasing age. In comparison to nondenture wearers, multispecies of Candida colonized the dentures thus presenting higher risk of candidiasis especially with increasing age.
Collapse
Affiliation(s)
- Bharathi Prakash
- Department of Microbiology, University College, Hampankatta, Mangalore, Karnataka, India
| | - Malathi Shekar
- Department of Fishery Microbiology, Karnataka, Veterinary, Animal and Fisheries Sciences, University College of Fisheries, Mangalore, Karnataka, India
| | - Biswajit Maiti
- Faculty of Biomedical Science, Nitte University Centre for Science Education and Research, (NUCSER), Nitte University, Deralakatte, Mangalore, Karnataka, India
| | - Indrani Karunasagar
- Faculty of Biomedical Science, Nitte University Centre for Science Education and Research, (NUCSER), Nitte University, Deralakatte, Mangalore, Karnataka, India
| | - Sreeshma Padiyath
- Department of Microbiology, Kurunji Venkatramana Gowda Medical College, Sullia, India
| |
Collapse
|
74
|
QIAN K, PAN H, LI Y, WANG G, ZHANG J, PAN J. Time-related surface modification of denture base acrylic resin treated by atmospheric pressure cold plasma. Dent Mater J 2016; 35:97-103. [DOI: 10.4012/dmj.2015-162] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Affiliation(s)
- Kun QIAN
- Department of General Dentistry, Peking University School and Hospital of Stomatology
| | - Hong PAN
- Academy for Advanced Interdisciplinary Studies, Peking University
- School of Stomatology, LanZhou University
| | - Yinglong LI
- Academy for Advanced Interdisciplinary Studies, Peking University
| | - Guomin WANG
- Academy for Advanced Interdisciplinary Studies, Peking University
| | - Jue ZHANG
- Academy for Advanced Interdisciplinary Studies, Peking University
- College of Engineering, Peking University
| | - Jie PAN
- Department of General Dentistry, Peking University School and Hospital of Stomatology
| |
Collapse
|
75
|
Effects of thermal cycling on surface roughness, hardness and flexural strength of polymethylmethacrylate and polyamide denture base resins. J Appl Biomater Funct Mater 2015; 13:e280-6. [PMID: 26350350 DOI: 10.5301/jabfm.5000236] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 02/28/2015] [Indexed: 11/20/2022] Open
Abstract
BACKGROUND The purpose of this study was to evaluate the effects of thermal cycling on the surface roughness, hardness and flexural strength of denture resins. METHODS Polyamide (PA; Deflex and Valplast) and polymethylmethacrylate (PMMA; QC-20 and Acron MC) denture materials were selected. A total of 180 specimens were fabricated and then divided into 3 groups. The first group (group 1) acted as a control and was not thermocycled. The second group (group 2) was subjected to thermocycling for 10,000 cycles in artificial saliva and 5,000 cycles in distilled water. The last group (group 3) was thermocycled for 20,000 cycles in artificial saliva and 10,000 cycles in distilled water. The surface roughness were measured with a profilometer. The hardness of the resins were measured with a Vickers Hardness Tester using a 100-gf load. The flexural strength test was performed using the universal test machine with a crosshead speed of 5 mm/min. Data were analyzed using statistical software. The results of the measurements in the 3 different tests were analyzed by Kruskal-Wallis test with Bonferroni correction. Multiple comparisons were made by Conover and Wilcoxon tests. RESULTS AND CONCLUSIONS There was a significant difference between the PMMA and PA groups in terms of surface roughness, hardness and transverse strength before and after thermal cycling (p<0.001). Thermal cycling did not change the surface roughness, hardness and flexural strength values of either the PMMA or PA group (p>0.001).
Collapse
|
76
|
Klironomos T, Katsimpali A, Polyzois G. The Effect of Microwave Disinfection on Denture Base Polymers, Liners and Teeth: A Basic Overview. Acta Stomatol Croat 2015; 49:242-53. [PMID: 27688409 PMCID: PMC4993596 DOI: 10.15644/asc49/3/7] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2015] [Accepted: 06/29/2015] [Indexed: 10/31/2022] Open
Abstract
The aim of this paper was to overview the current scientific knowledge concerning the effect of microwave disinfection on denture related material properties. Cross-infection control in dentistry is a significant issue in everyday clinical practice due to the recent increase in some infectious diseases such as hepatitis B, C and AIDS and therefore numerous methods of disinfection have been used. The most widespread method of disinfection used in everyday practice is chemical, however, studies have suggested that chemical disinfectants alter the physical and mechanical properties of the acrylic resins and enable the growth and proliferation of certain bacteria. Therefore, microwaves were introduced as an easy to use-and-access, low cost, chemical free alternative. The question that arose was if and in what way the microwave irradiation affected the denture related material properties. Microwaving affects the denture resin bases, liners and teeth in different ways. The results showed that microwave disinfection could be a safe alternative for the disinfection of denture bases and liners compared to the chemical one, when the procedure is carried out in dry conditions, but could possibly cause dimensional changes of clinical significance on them when the irradiation takes place in wet environment. It also seems to have no detrimental effects of clinical importance on the flexural properties, impact strength and hardness of denture resins and the bond, flexural strength, porosity and hardness of denture liners. The effects of microwave disinfection on the hardness of denture teeth and teeth/denture bond strength are still controversial and no safe conclusions can be drawn.
Collapse
Affiliation(s)
| | | | - Gregory Polyzois
- Professor, Department of Removable Prosthodontics, Dental School, University of Athens, Athens, Greece
| |
Collapse
|
77
|
The Beneficial Effect of Equisetum giganteum L. against Candida Biofilm Formation: New Approaches to Denture Stomatitis. EVIDENCE-BASED COMPLEMENTARY AND ALTERNATIVE MEDICINE 2015; 2015:939625. [PMID: 26290676 PMCID: PMC4531177 DOI: 10.1155/2015/939625] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/25/2015] [Accepted: 07/09/2015] [Indexed: 11/30/2022]
Abstract
Equisetum giganteum L. (E. giganteum), Equisetaceae, commonly called “giant horsetail,” is an endemic plant of Central and South America and is used in traditional medicine as diuretic and hemostatic in urinary disorders and in inflammatory conditions among other applications. The chemical composition of the extract EtOH 70% of E. giganteum has shown a clear presence of phenolic compounds derived from caffeic and ferulic acids and flavonoid heterosides derived from quercitin and kaempferol, in addition to styrylpyrones. E. giganteum, mainly at the highest concentrations, showed antimicrobial activity against the relevant microorganisms tested: Escherichia coli, Staphylococcus aureus, and Candida albicans. It also demonstrated antiadherent activity on C. albicans biofilms in an experimental model that is similar to dentures. Moreover, all concentrations tested showed anti-inflammatory activity. The extract did not show cytotoxicity in contact with human cells. These properties might qualify E. giganteum extract to be a promising alternative for the topic treatment and prevention of oral candidiasis and denture stomatitis.
Collapse
|
78
|
Aoun G, Cassia A, Berberi A. Effectiveness of a Chlorhexidine Digluconate 0.12% and Cetylpyridinium Chloride 0.05% Solution in eliminating Candida albicans Colonizing Dentures: A Randomized Clinical in vivo Study. J Contemp Dent Pract 2015; 16:433-436. [PMID: 26323444 DOI: 10.5005/jp-journals-10024-1702] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
BACKGROUND Effective denture hygiene is important for patients suffering from denture stomatitis (DS). This study aimed to evaluate the efficacy of a solution containing 0.12% chlorhexidine (CHX) digluconate and 0.05% cetylpyridinium chloride (CPC) in eliminating Candida albicans colonizing dentures. MATERIALS AND METHODS Forty denture wearers (11 men, 29 women; age range 40 to 80 years) with clinical evidence of DS were randomly divided into two groups, one test and one control. The dentures of the test group were treated by immersion in a solution of 0.12% CHX and 0.05% CPC while those of the control group were immersed in distilled water. Swabs were collected from the fitting surfaces of the upper dentures prior and post cleaner use and examined mycologically. RESULTS Reduction in the number of colony-forming units (CFU) of Candida albicans after immersion of the dentures in a solution of 0.12% CHX and 0.05% CPC was significantly greater than that of the control group. CONCLUSION A solution of 0.12% CHX and 0.05% CPC tested as a product of disinfection of the acrylic dentures showed significant results after immersion of 8 night hours for 4 days.
Collapse
Affiliation(s)
- Georges Aoun
- Assistant Professor, Department of Oral Pathology and Diagnosis, School of Dentistry, Lebanese University, Beirut, Lebanon, e-mail:
| | - Antoine Cassia
- Department of Oral Pathology and Diagnosis, School of Dentistry, Lebanese University, Beirut, Lebanon
| | - Antoine Berberi
- Department of Oral and Maxillofacial Surgery, School of Dentistry, Lebanese University, Beirut, Lebanon
| |
Collapse
|
79
|
Jiao Y, Ma S, Li J, Shan L, Yang Y, Li M, Chen J. The influences of N-acetyl cysteine (NAC) on the cytotoxicity and mechanical properties of Poly-methylmethacrylate (PMMA)-based dental resin. PeerJ 2015; 3:e868. [PMID: 25922788 PMCID: PMC4411485 DOI: 10.7717/peerj.868] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2015] [Accepted: 03/10/2015] [Indexed: 11/26/2022] Open
Abstract
Objectives. This study aimed to investigate the influences of N-acetyl cysteine (NAC) on cytotoxicity and mechanical properties of Poly-methylmethacrylate (PMMA) dental resins. Methods. Experimental PMMA resin was prepared by incorporating various concentrations of NAC (0, 0.15, 0.3, 0.6 and 0.9 wt.%). MTT assay was performed to investigate viability of human dental pulp cells after exposure to extract of PMMA resin with or without NAC. Cell adhesion on resin specimens was examined with scanning electron microscopy. Degree of conversion was studied with Fourier Transform Infrared Spectroscopy (FTIR). Flexural strength, microhardness and surface roughness was evaluated using a universal testing machine, microhardness tester and optical profilometer, respectively. Results. Incorporation of NAC into PMMA resin significantly reduced its cytotoxicity and enhanced cell adhesion on its surface. NAC induced negative influences on the mechanical and physical properties of PMMA resin in a dose-dependent manner. The degree of conversion for all experimental PMMA resins reached as high as 72% after 24 h of polymerization. All the tested properties were maintained when the concentration of incorporated NAC was 0.15 wt.%. Conclusion. The addition of 0.15 wt.% NAC remarkably improved biocompatibility of PMMA resin without exerting significant negative influence on its mechanical and physical properties.
Collapse
Affiliation(s)
- Yang Jiao
- State Key Laboratory of Military Stomatology, Department of Prosthodontics, School of Stomatology, the Fourth Military Medical University , Xi'an , PR China
| | - Sai Ma
- State Key Laboratory of Military Stomatology, Department of Prosthodontics, School of Stomatology, the Fourth Military Medical University , Xi'an , PR China
| | - Jing Li
- Department of Orthopaedic Oncology, Xijing Hospital Affiliated to the Fourth Military Medical University , Xi'an , PR China
| | - Lequn Shan
- Department of Orthopaedic Surgery, Tangdu hospital, the Fourth Military Medical University , Xi'an , PR China
| | - Yanwei Yang
- State Key Laboratory of Military Stomatology, Department of Prosthodontics, School of Stomatology, the Fourth Military Medical University , Xi'an , PR China
| | - Meng Li
- State Key Laboratory of Military Stomatology, Department of Prosthodontics, School of Stomatology, the Fourth Military Medical University , Xi'an , PR China
| | - Jihua Chen
- State Key Laboratory of Military Stomatology, Department of Prosthodontics, School of Stomatology, the Fourth Military Medical University , Xi'an , PR China
| |
Collapse
|
80
|
Nakahara T, Harada A, Yamada Y, Odashima Y, Nakamura K, Inagaki R, Kanno T, Sasaki K, Niwano Y. Influence of a new denture cleaning technique based on photolysis of H(2)O(2) the mechanical properties and color change of acrylic denture base resin. Dent Mater J 2015; 32:529-36. [PMID: 23903632 DOI: 10.4012/dmj.2013-047] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
The purpose of this study was to evaluate the influence of a disinfection technique based on photolysis of H2O2 on the mechanical properties and color change of acrylic denture base resin. Resin specimens were immersed in 1 M H2O2 irradiated with light-emitting diode (LED) light at 400 nm for 1 week. The immersion duration of 1 week (168 h) corresponded to performing approximately 500 times of 20-min cleaning. Hydroxyl radicals are potent oxidants and they were generated via the photolysis of H2O2. Oxidative damage caused by these radicals included reduced flexural strength and altered color for the acrylic resin. Nonetheless, the degraded flexural strength and altered color of acrylic resin after 500 times of cleaning in the disinfection system would be within clinically acceptable levels.
Collapse
Affiliation(s)
- Tatsuro Nakahara
- Division of Fixed Prosthodontics, Tohoku University Graduate School of Dentistry, 4-1 Seiryo-machi, Aoba-ku, Sendai 980-8575, Japan
| | | | | | | | | | | | | | | | | |
Collapse
|
81
|
PAN H, WANG G, PAN J, YE G, SUN K, ZHANG J, WANG J. Cold plasma-induced surface modification of heat-polymerized acrylic resin and prevention of early adherence of Candida albicans . Dent Mater J 2015; 34:529-36. [DOI: 10.4012/dmj.2015-035] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Affiliation(s)
- Hong PAN
- School of Stomatology, Lanzhou University
- Academy for Advanced Interdisciplinary Studies, Peking University
| | - Guomin WANG
- Academy for Advanced Interdisciplinary Studies, Peking University
| | - Jie PAN
- School of Stomatology, Peking University
| | - Guopin YE
- School of Stomatology, Lanzhou University
- Academy for Advanced Interdisciplinary Studies, Peking University
| | - Ke SUN
- School of Stomatology, Lanzhou University
- Academy for Advanced Interdisciplinary Studies, Peking University
| | - Jue ZHANG
- Academy for Advanced Interdisciplinary Studies, Peking University
| | - Jing WANG
- School of Stomatology, Lanzhou University
| |
Collapse
|
82
|
Kumari SV, Taruna M, Chittaranjan B, Reddy SM, Reddy KKE, Kulkarni G. A qualitative analysis to compare the effects of surface machining of conventional denture base resin and two soft liners: a scanning electron microscopic study. J Clin Diagn Res 2015; 9:ZC30-4. [PMID: 25738082 DOI: 10.7860/jcdr/2015/11310.5474] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2014] [Accepted: 11/20/2014] [Indexed: 11/24/2022]
Abstract
INTRODUCTION The denture base acrylic resins require adjustments for various reasons. During this process there is an alteration in the surface characteristics of the denture base. Rough surfaces promote the bacterial adhesion and plaque accumulation; therefore it is important to know the character of the surface left by instrumentation on denture base materials. This study evaluated the surface characteristics of the machined surfaces of heat-cured acrylic denture base resin, GC supersoft and Permasoft softliners. MATERIALS AND METHODS Thirty 15×15×1.5mm acrylic resin specimens were fabricated with each of three acrylic resins: Lucitone 199 denture base resin (Group I), GC supersoft (Group II) and Permasoft (Group III) softliners. They were further divided into three sub Groups A, B and C, in which Sub Group A was control group that is smooth produced against the glass. Sub Group B was produced by machining with the tungsten carbide bur and Sub group C is machined with the stone bur. Each surface was evaluated by a Scanning electron microscope and data were analyzed by analysis of variance followed by Tukey's HSD test. RESULTS Stone bur produced smoother surface (Ra 3.6681μm± 0.254) on Lucitone199 than the tungsten carbide bur (Ra 5.3881μm ± 0.3373). Carbide bur produced a smoother surface on the GC super soft (Ra 1.617097μm ± 0.191767) and Permasoft softliners (Ra 2.237419μm ± 0.354259). Whereas stone bur produced rougher surface on GC supersoft(Ra 2.6μm) and Permasoft (Ra 4.184839μm ± 0.409869) softliners. CONCLUSION The present study shows each type of rotary instrument produces its own characteristic surface on each type of denture base materials and that care is needed when selecting the most appropriate instrument to adjust denture base materials. These results can have a significant clinical implication. While using Lucitone 199 stone bur can be used for chair side adjustments. Tungsten carbide bur can be used for GC supersoft and Permasoft softliners to achieve smoother surface.
Collapse
Affiliation(s)
- Santoshi V Kumari
- Senior Lecturer, Department of Prosthodontics, MNR Dental College and Hospital , Sangareddy, Telangana, India
| | - M Taruna
- Professor, Department of Prosthodontics, Kamineni Institute of Dental Sciences , Narketpally, Telangana, India
| | - B Chittaranjan
- Professor & Head, Department of Prosthodontics, Kamineni Institute of Dental Sciences , Narketpally, Telangana,India
| | - Sushendhar M Reddy
- Senior Lecturer, Department of Prosthodontics, SVS Dental College and Hospital , Mahabubnagar, Telangana, India
| | - Kranti Kiran E Reddy
- Reader, Department of Oral Pathology & Microbiology, MNR Dental College and Hospital , Sangareddy, Telangana, India
| | - Ganesh Kulkarni
- Senior Lecturer, Department of Oral Pathology, Malla Reddy Dental College and Hospital , Jeedimetla, Suraram, Telangana, India
| |
Collapse
|
83
|
Dalwai S, Rodrigues SJ, Baliga S, Shenoy VK, Shetty TB, Pai UY, Saldanha S. Comparative evaluation of antifungal action of tea tree oil, chlorhexidine gluconate and fluconazole on heat polymerized acrylic denture base resin - anin vitrostudy. Gerodontology 2014; 33:402-9. [DOI: 10.1111/ger.12176] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/18/2014] [Indexed: 11/27/2022]
Affiliation(s)
- Sameen Dalwai
- Department of Prosthodontics; Manipal College of Dental Sciences; Mangalore India
| | - Shobha J. Rodrigues
- Department of Prosthodontics; Manipal College of Dental Sciences; Mangalore India
| | - Shrikala Baliga
- Department of Microbiology; Kasturba Medical College; Mangalore India
| | - Vidya K. Shenoy
- Department Of Prosthodontics; A J Institute of Dental Sciences; Mangalore India
| | - Thilak B. Shetty
- Department of Prosthodontics; Manipal College of Dental Sciences; Mangalore India
| | - Umesh Y. Pai
- Department of Prosthodontics; Manipal College of Dental Sciences; Mangalore India
| | - Sharon Saldanha
- Department of Prosthodontics; Manipal College of Dental Sciences; Mangalore India
| |
Collapse
|
84
|
The effect of dentifrice abrasion on denture topography and the subsequent retention of microorganisms on abraded surfaces. J Prosthet Dent 2014; 112:1513-22. [DOI: 10.1016/j.prosdent.2014.05.009] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2013] [Revised: 05/14/2014] [Accepted: 05/14/2014] [Indexed: 11/24/2022]
|
85
|
Gungor H, Gundogdu M, Yesil Duymus Z. Investigation of the effect of different polishing techniques on the surface roughness of denture base and repair materials. J Prosthet Dent 2014; 112:1271-7. [DOI: 10.1016/j.prosdent.2014.03.023] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2013] [Revised: 03/22/2014] [Accepted: 03/26/2014] [Indexed: 11/16/2022]
|
86
|
Nagaral S, Desai RG, Kamble V, Patil AKG. Isolation of Candida species from the oral cavity and fingertips of complete denture wearers. J Contemp Dent Pract 2014; 15:712-716. [PMID: 25825095 DOI: 10.5005/jp-journals-10024-1604] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
BACKGROUND Wearing a dental prosthesis is known to increase oral candidal colonization and predispose the wearer to oral candidosis. Denture wearers frequently use fingers to take the prosthesis out of their mouth. Oral Candida, if present may contaminate wearer's finger. The objective of this study was to investigate the simultaneous candidal colonization of oral cavity and fingertips of complete denture wearers. MATERIALS AND METHODS A total of 25 apparently healthy male subjects who had worn complete dentures for at least 1 year were selected. Information about each patient's denture age, denture hygiene, handling, and wearing habits, and hand washing habits after denture handling were be obtained. Intraoral examination of all the patients was done. For microbiological examination samples were collected from the fingertip and oral rinse of each patient. Candida species were identified with use of germ tube test and commercially available yeast identification system. Data was statistically analyzed. Significance was set at p < 0.05. RESULTS It was found that frequency of hand washing, denture handling and denture stomatitis with respect to fingertip candidal isolation was not statistically significant. But poor denture hygiene and denture stomatitis with respect to oral candidal colonization was statistically significant. CONCLUSION Denture wearers with oral Candida had a higher prevalence of Candida contamination on their fingers. Patients with removable prostheses should be informed about the importance of proper prosthesis and personal hygiene and the possibility of microbial contamination of the hands and other parts of the body.
Collapse
Affiliation(s)
- Suresh Nagaral
- Reader, Department of Prosthodontics, ACPM Dental College and Hospital Dhule-424001, Maharashtra, India, Phone: 9595833155 e-mail:
| | - Raviraj G Desai
- Professor, Department of Prosthodontics, PMNM Dental College Bagalkot, Karnataka, India
| | - Vikas Kamble
- Professor and Head, Department of Prosthodontics, PMNM Dental College Bagalkot, Karnataka, India
| | - Anand Kumar G Patil
- Professor and Head, Department of Prosthodontics, Mahsarovar Dental College Bhopal, Madhya Pradesh, India
| |
Collapse
|
87
|
de Foggi CC, Machado AL, Zamperini CA, Fernandes D, Wady AF, Vergani CE. Effect of surface roughness on the hydrophobicity of a denture-base acrylic resin and Candida albicans
colonization. ACTA ACUST UNITED AC 2014; 7:141-8. [DOI: 10.1111/jicd.12125] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2014] [Accepted: 08/07/2014] [Indexed: 11/28/2022]
Affiliation(s)
- Camila C. de Foggi
- Araraquara Dental School; Department of Dental Materials and Prosthodontics; São Paulo State University; São Paulo Brazil
| | - Ana L. Machado
- Araraquara Dental School; Department of Dental Materials and Prosthodontics; São Paulo State University; São Paulo Brazil
| | - Camila A. Zamperini
- Araraquara Dental School; Department of Dental Materials and Prosthodontics; São Paulo State University; São Paulo Brazil
| | - Darcy Fernandes
- Araraquara Dental School; Department of Dental Materials and Prosthodontics; São Paulo State University; São Paulo Brazil
| | - Amanda F. Wady
- Araraquara Dental School; Department of Dental Materials and Prosthodontics; São Paulo State University; São Paulo Brazil
| | - Carlos E. Vergani
- Araraquara Dental School; Department of Dental Materials and Prosthodontics; São Paulo State University; São Paulo Brazil
| |
Collapse
|
88
|
Jackson S, Coulthwaite L, Loewy Z, Scallan A, Verran J. Biofilm development by blastospores and hyphae of Candida albicans on abraded denture acrylic resin surfaces. J Prosthet Dent 2014; 112:988-93. [DOI: 10.1016/j.prosdent.2014.02.003] [Citation(s) in RCA: 41] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
89
|
Sczepanski F, Sczepanski CRB, Berger SB, Consani RLX, Gonini-Júnior A, Guiraldo RD. Effect of sodium hypochlorite and peracetic acid on the surface roughness of acrylic resin polymerized by heated water for short and long cycles. Eur J Dent 2014; 8:533-537. [PMID: 25512737 PMCID: PMC4253112 DOI: 10.4103/1305-7456.143638] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
OBJECTIVE To evaluate the surface roughness of acrylic resin submitted to chemical disinfection via 1% sodium hypochlorite (NaClO) or 1% peracetic acid (C2H4O3). MATERIALS AND METHODS The disc-shaped resin specimens (30 mm diameter ×4 mm height) were polymerized by heated water using two cycles (short cycle: 1 h at 74°C and 30 min at 100°C; conventional long cycle: 9 h at 74°C). The release of substances by these specimens in water solution was also quantified. Specimens were fabricated, divided into four groups (n = 10) depending on the polymerization time and disinfectant. After polishing, the specimens were stored in distilled deionized water. Specimens were immersed in 1% NaClO or 1% C2H4O3 for 30 min, and then were immersed in distilled deionized water for 20 min. The release of C2H4O3 and NaClO was measured via visual colorimetric analysis. Roughness was measured before and after disinfection. Roughness data were subjected to two-way ANOVA and Tukey's test. RESULTS There was no interaction between polymerization time and disinfectant in influencing the average surface roughness (Ra, P = 0.957). Considering these factors independently, there were significant differences between short and conventional long cycles (P = 0.012), but no significant difference between the disinfectants hypochlorite and C2H4O3 (P = 0.366). Visual colorimetric analysis did not detect release of substances. CONCLUSION It was concluded that there was the difference in surface roughness between short and conventional long cycles, and disinfection at acrylic resins polymerized by heated water using a short cycle modified the properties of roughness.
Collapse
Affiliation(s)
- Felipe Sczepanski
- Department of Restorative Dentistry, School of Dentistry, University North of Parana (UNOPAR), Londrina, PR, Brazil
| | | | - Sandrine Bittencourt Berger
- Department of Restorative Dentistry, School of Dentistry, University North of Parana (UNOPAR), Londrina, PR, Brazil
| | - Rafael Leonardo Xediek Consani
- Department of Prosthodontics and Periodontics, Piracicaba Dental School, State University of Campinas (UNICAMP), Piracicaba, SP, Brazil
| | - Alcides Gonini-Júnior
- Department of Restorative Dentistry, School of Dentistry, University North of Parana (UNOPAR), Londrina, PR, Brazil
| | - Ricardo Danil Guiraldo
- Department of Restorative Dentistry, School of Dentistry, University North of Parana (UNOPAR), Londrina, PR, Brazil
| |
Collapse
|
90
|
Khalaf S, Ariffin Z, Husein A, Reza F. Surface Coating of Gypsum-Based Molds for Maxillofacial Prosthetic Silicone Elastomeric Material: The Surface Topography. J Prosthodont 2014; 24:419-23. [PMID: 25219956 DOI: 10.1111/jopr.12213] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/22/2014] [Indexed: 11/30/2022] Open
Abstract
PURPOSE This study aimed to compare the surface roughness of maxillofacial silicone elastomers fabricated in noncoated and coated gypsum materials. This study was also conducted to characterize the silicone elastomer specimens after surfaces were modified. MATERIALS AND METHODS A gypsum mold was coated with clear acrylic spray. The coated mold was then used to produce modified silicone experimental specimens (n = 35). The surface roughness of the modified silicone elastomers was compared with that of the control specimens, which were prepared by conventional flasking methods (n = 35). An atomic force microscope (AFM) was used for surface roughness measurement of silicone elastomer (unmodified and modified), and a scanning electron microscope (SEM) was used to evaluate the topographic conditions of coated and noncoated gypsum and silicone elastomer specimens (unmodified and modified) groups. After the gypsum molds were characterized, the fabricated silicone elastomers molded on noncoated and coated gypsum materials were evaluated further. Energy-dispersive X-ray spectroscopy (EDX) analysis of gypsum materials (noncoated and coated) and silicone elastomer specimens (unmodified and modified) was performed to evaluate the elemental changes after coating was conducted. Independent t test was used to analyze the differences in the surface roughness of unmodified and modified silicone at a significance level of p < 0.05. RESULTS Roughness was significantly reduced in the silicone elastomers processed against coated gypsum materials (p < 0.001). The AFM and SEM analysis results showed evident differences in surface smoothness. EDX data further revealed the presence of the desired chemical components on the surface layer of unmodified and modified silicone elastomers. CONCLUSIONS Silicone elastomers with lower surface roughness of maxillofacial prostheses can be obtained simply by coating a gypsum mold.
Collapse
Affiliation(s)
- Salah Khalaf
- Prosthodontics Unit, Faculty of Dentistry, Universiti Sains Malaysia, Kelantan, Malaysia.,Prosthodontics Unit, University of Anbar, Anbar, Iraq
| | - Zaihan Ariffin
- Prosthodontics Unit, Faculty of Dentistry, Universiti Sains Malaysia, Kelantan, Malaysia
| | - Adam Husein
- Prosthodontics Unit, Faculty of Dentistry, Universiti Sains Malaysia, Kelantan, Malaysia
| | - Fazal Reza
- Prosthodontics Unit, Faculty of Dentistry, Universiti Sains Malaysia, Kelantan, Malaysia
| |
Collapse
|
91
|
Chladek G, Żmudzki J, Kasperski J. Long-Term Soft Denture Lining Materials. MATERIALS 2014; 7:5816-5842. [PMID: 28788163 PMCID: PMC5456172 DOI: 10.3390/ma7085816] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/13/2014] [Revised: 07/31/2014] [Accepted: 08/01/2014] [Indexed: 11/16/2022]
Abstract
Long-term soft denture lining (LTSDL) materials are used to alleviate the trauma associated with wearing complete dentures. Despite their established clinical efficacy, the use of LTSDLs has been limited due to the unfavorable effects of the oral environment on some of their mechanical and performance characteristics. The unresolved issue of LTSDL colonization by Candida albicans is particularly problematic. Silicone-based LTSDL (SLTSDL) materials, which are characterized by more stable hardness, sorption and solubility than acrylic-based LTSDLs (ALTSDLs), are currently the most commonly used LTSDLs. However, SLTSDLs are more prone to debonding from the denture base. Moreover, due to their limitations, the available methods for determining bond strength do not fully reflect the actual stability of these materials under clinical conditions. SLTSDL materials exhibit favorable viscoelastic properties compared with ALTSDLs. Furthermore, all of the lining materials exhibit an aging solution-specific tendency toward discoloration, and the available cleansers are not fully effective and can alter the mechanical properties of LTSDLs. Future studies are needed to improve the microbiological resistance of LTSDLs, as well as some of their performance characteristics.
Collapse
Affiliation(s)
- Grzegorz Chladek
- Faculty of Mechanical Engineering, Institute of Engineering Materials and Biomaterials, Silesian University of Technology, ul. Konarskiego 18a, Gliwice 44-100, Poland.
| | - Jarosław Żmudzki
- Faculty of Mechanical Engineering, Institute of Engineering Materials and Biomaterials, Silesian University of Technology, ul. Konarskiego 18a, Gliwice 44-100, Poland.
| | - Jacek Kasperski
- Department of Prosthetic Dentistry, Medical University of Silesia, pl. Akademicki 17, Bytom 41-902, Poland.
| |
Collapse
|
92
|
Urban VM, Lima TF, Bueno MG, Giannini M, Arioli Filho JN, de Almeida ALPF, Neppelenbroek KH. Effect of the addition of antimicrobial agents on Shore A hardness and roughness of soft lining materials. J Prosthodont 2014; 24:207-14. [PMID: 25082183 DOI: 10.1111/jopr.12205] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/03/2014] [Indexed: 11/27/2022] Open
Abstract
PURPOSE While the incorporation of antimicrobial agents into soft denture liners has been suggested as a reliable alternative treatment for denture stomatitis, it may affect the liner's properties. The effect of addition of antimicrobial agents for the treatment of denture stomatitis on the surface roughness and Shore A hardness of soft lining materials was evaluated. MATERIALS AND METHODS The test groups comprised specimens (36 × 7 × 6 mm(3) ) of soft materials (Softone and Trusoft) without (control) or with incorporation of drugs (nystatin, miconazole, ketoconazole, chlorhexidine diacetate, and itraconazole). Hardness (Shore A) and roughness (Ra) were evaluated after immersion of specimens (n = 10) in distilled water at 37°C for 24 hours, 7 and 14 days. Data were analyzed by 3-way ANOVA/Tukey's test (α = 0.05). RESULTS After 14 days, an increase (p < 0.05) was observed in the hardness of soft materials with time for the modified specimens, except for itraconazole. Addition of drugs increased the Softone roughness only for the addition of miconazole and chlorhexidine (p < 0.05), and did not increase the roughness of Trusoft with time. Only chlorhexidine and itraconazole altered the roughness compared to the control for each material (p < 0.05). CONCLUSIONS The smallest changes of hardness and roughness with time in the modified groups compared to controls were observed for itraconazole groups for both materials.
Collapse
Affiliation(s)
- Vanessa M Urban
- Department of Dentistry, State University of Ponta Grossa, Ponta Grossa, Brazil
| | | | | | | | | | | | | |
Collapse
|
93
|
In vitro antifungal evaluation of seven different disinfectants on acrylic resins. BIOMED RESEARCH INTERNATIONAL 2014; 2014:519098. [PMID: 24995305 PMCID: PMC4068041 DOI: 10.1155/2014/519098] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 02/28/2014] [Revised: 05/19/2014] [Accepted: 05/22/2014] [Indexed: 11/29/2022]
Abstract
Objective. The aim of this study was to evaluate alternative methods for the disinfection of denture-based materials. Material and Methods. Two different denture-based materials were included in the study. Before microbial test, the surface roughness of the acrylic resins was evaluated. Then, the specimens were divided into 8 experimental groups (n = 10), according to microorganism considered and disinfection methods used. The specimens were contaminated in vitro by standardized suspensions of Candida albicans ATCC#90028 and Candida albicans oral isolate. The following test agents were tested: sodium hypochlorite (NaOCl 1%), microwave (MW) energy, ultraviolet (UV) light, mouthwash containing propolis (MCP), Corega Tabs, 50% and 100% white vinegar. After the disinfection procedure, the number of remaining microbial cells was evaluated in CFU/mL. Kruskal-Wallis, ANOVA, and Dunn's test were used for multiple comparisons. Mann Whitney U test was used to compare the surface roughness. Results. Statistically significant difference (P < 0.05) was found between autopolymerised and heat-cured acrylic resins. The autopolymerised acrylic resin surfaces were rougher than surfaces of heat-cured acrylic resin. The most effective disinfection method was 100% white vinegar for tested microorganisms and both acrylic resins. Conclusion. This study showed that white vinegar 100% was the most effective method for tested microorganisms. This agent is cost-effective and easy to access and thus may be appropriate for household use.
Collapse
|
94
|
Abstract
This review describes the contemporary aspects of plasma application in dentistry. Previous studies on plasma applications were classified into two categories, surface treatment and direct applications, and were reviewed, respectively according to the approach. The current review discussed modification of dental implant surface, enhancing of adhesive qualities, enhancing of polymerization, surface coating and plasma cleaning under the topics of surface treatment. Microbicidal activities, decontamination, root canal disinfection and tooth bleaching were reviewed as direct applications with other miscellaneous ones. Non-thermal atmospheric pressure plasma was of particular focus since it is gaining considerable attention due to the possibility for its use in living tissues. Future perspectives have also been discussed briefly. Although it is still not popular among dentists, plasma has shown promises in several areas of dentistry and is now opening a new era of plasma dentistry.
Collapse
|
95
|
Huh JB, Lim Y, Youn HI, Chang BM, Lee JY, Shin SW. Effect of denture cleansers on Candida albicans biofilm formation over resilient liners. J Adv Prosthodont 2014; 6:109-14. [PMID: 24843395 PMCID: PMC4024554 DOI: 10.4047/jap.2014.6.2.109] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2013] [Revised: 06/24/2013] [Accepted: 01/20/2014] [Indexed: 11/08/2022] Open
Abstract
PURPOSE The purpose of this study was to analyze the effect of denture cleansers on Candida albicans biofilm formation over resilient liners and to evaluate compatibility between resilient liners and denture cleansers. MATERIALS AND METHODS Acrylic resin (Lucitone 199®) and 3 resilient liners (COE-SOFT™, GC RELINE™ and SOFRELINER TOUGH TOUGH®) were incubated in denture cleansers (Polident® and Cleadent®) for 8 hours a day and in unstimulated saliva for 16 hours a day (n=25/gp) for 60 days. Two-way and three-way repeated measures ANOVA were performed to compare the surface roughness (Ra), pH and C. albicans binding level by radioisotope (α=0.05). The statistical significance of the relation between Ra and adhesion was evaluated by correlation analysis. RESULTS THE DEGREE OF RA WAS SIGNIFICANTLY DECREASED IN THE FOLLOWING ORDER: COE-SOFT™, acrylic resin, GC RELINE™ and SOFRELINER TOUGH®. The immersion in denture cleansers significantly increased Ra of resilient liners, except for SOFRELINER TOUGH® in Cleadent®. No significant differences in pH curves were observed among groups immersed in distilled water and denture cleansers. The binding levels of C. albicans were significantly decreased in the following order: COE-SOFT™, GC RELINE™, SOFRELINER TOUGH®, and acrylic resin. The immersion in Cleadent® seemed to decrease C. albicans binding level on GC RELINE™ and SOFRELINER TOUGH®. CONCLUSION Based on the C. albicans binding levels results, it is not recommended to immerse COE-SOFT™ in denture cleansers, and GC RELINE™ and SOFRELINER TOUGH® should be immersed in Cleadent®.
Collapse
Affiliation(s)
- Jung-Bo Huh
- Department of Prosthodontics, Busan National University, School of Dentistry, Dental Research Institute, Yangsan, Republic of Korea
| | - Younghun Lim
- College of Arts and Science, New York University, NY, USA
| | - Hye-In Youn
- Department of Prosthodontics, Institute for Clinical Dental Research, Korea University Guro Hospital, Korea University, Seoul, Republic of Korea
| | - Brian Myung Chang
- Maxillofacial Prosthodontics, Head and Neck Institute, Cleveland Clinic, Cleveland, OH, USA
| | - Jeong-Yol Lee
- Department of Prosthodontics, Institute for Clinical Dental Research, Korea University Guro Hospital, Korea University, Seoul, Republic of Korea
| | - Sang-Wan Shin
- Department of Prosthodontics, Institute for Clinical Dental Research, Korea University Guro Hospital, Korea University, Seoul, Republic of Korea
| |
Collapse
|
96
|
Uzunoglu E, Yildirim Bicer AZ, Dolapci I, Dogan A. Biofilm-forming ability and adherence to poly-(methyl-methacrylate) acrylic resin materials of oral Candida albicans strains isolated from HIV positive subjects. J Adv Prosthodont 2014; 6:30-4. [PMID: 24605203 PMCID: PMC3942524 DOI: 10.4047/jap.2014.6.1.30] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2013] [Revised: 10/30/2013] [Accepted: 12/30/2013] [Indexed: 12/04/2022] Open
Abstract
PURPOSE This study evaluated the adhesion to acrylic resin specimens and biofilm formation capability of Candida albicans strains isolated from HIV positive subjects' oral rinse solutions. MATERIALS AND METHODS The material tested was a heat-cured acrylic resin (Acron Duo). Using the adhesion and crystal violet assays, 14 oral Candida albicans isolated from HIV-positive subjects and 2 references Candida strains (C. albicans ATCC 90028 and C. albicans ATCC 90128) were compared for their biofilm production and adhesion properties to acrylic surfaces in vitro. RESULTS There were no significant differences in adhesion (P=.52) and biofilm formation assays (P=.42) by statistical analysis with Mann-Whitney test. CONCLUSION Denture stomatitis and increased prevalence of candidal carriage in HIV infected patients is unlikely to be related to the biofilm formation and adhesion abilities of C. albicans to acrylic resin materials.
Collapse
Affiliation(s)
- Emel Uzunoglu
- Department of Microbiology, Giresun Prof. Dr. A. İlhan Özdemir Hospital, Giresun, Turkey
| | | | - Istar Dolapci
- Department of Microbiology, Faculty of Medicine, Ankara University, Ankara, Turkey
| | - Arife Dogan
- Department of Prosthodontics, Faculty of Dentistry, Gazi University, Ankara, Turkey
| |
Collapse
|
97
|
Sahin C, Ayyildiz S. Correlation between microleakage and screw loosening at implant-abutment connection. J Adv Prosthodont 2014; 6:35-8. [PMID: 24605204 PMCID: PMC3942525 DOI: 10.4047/jap.2014.6.1.35] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2013] [Revised: 12/31/2013] [Accepted: 01/06/2014] [Indexed: 11/16/2022] Open
Abstract
PURPOSE This study aimed to evaluate the correlation between microleakage and screw loosening at different types of implant-abutment connections and/or geometries measuring the torque values before and after the leakage tests. MATERIALS AND METHODS Three different abutment types (Intenal hex titanium, internal hex zirconium, morse tapered titaniuım) with different geometries were connected to its own implant fixture. All the abutments were tightened with a standard torque value then the composition was connected to the modified fluid filtration system. After the measurements of leakage removal torque values were re-measured. Kruskal-wallis test was performed for non-parametric and one-way ANOVA was performed for parametric data. The correlation was evaluated using Spearman Correlation Test (α=0.05). RESULTS Significantly higher microleakage was found at the connection of implant-internal hex zirconium abutment. Observed mean torque value loss was also significantly higher than other connection geometries. Spearman tests revealed a significant correlation between microleakage and screw loosening. CONCLUSION Microleakage may provoke screw loosening. Removing torque values rationally decrease with the increase of microleakage.
Collapse
Affiliation(s)
- Cem Sahin
- School of Health Services, Dental Prosthetics Technology, Hacettepe University, Ankara, Turkey
| | - Simel Ayyildiz
- Department of Prosthodontics, Center for Dental Sciences, Gulhane Military Medical Academy, Ankara, Turkey
| |
Collapse
|
98
|
Inger M, Bennani V, Farella M, Bennani F, Cannon RD. Efficacy of air/water syringe tip sterilization. Aust Dent J 2014; 59:87-92. [PMID: 24494727 DOI: 10.1111/adj.12146] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/26/2013] [Indexed: 11/30/2022]
Abstract
BACKGROUND Dental procedures involve contact between instruments and the patient's tissues, blood or saliva. This study evaluated the efficacy of the standardized sterilization of non-disposable air/water syringe tips and corrosion and contaminant build-up in these tips. METHODS The bacterial contamination of single-use and multiple-use non-disposable air/water syringe tips after routine use and sterilization was compared to that of single-use disposable tips by microbial culturing on PCA and blood agar plates. The effect of flushing the syringe tips prior to sterilization was also measured. The amount of corrosion in single-use and multiple-use non-disposable syringes was measured by SEM and EDS analyses. RESULTS Non-disposable syringe tips had significantly (p < 0.05) greater bacterial contamination than single-use disposable tips. There were no statistically different levels of contamination between flushed and non-flushed non-disposable syringes or between single-use and multiple-use non-disposable syringes. SEM and EDS analyses showed greater evidence of corrosion and contaminant build-up in multiple-use syringes compared to single-use non-disposable syringes. CONCLUSIONS Sterilization of non-disposable air/water syringes is not completely effective and rinsing, or the number of uses, does not affect the effectiveness of sterilization. There may be a lower risk of cross-infection from the use of disposable air/water syringe tips, instead of non-disposable ones.
Collapse
Affiliation(s)
- M Inger
- School of Dentistry, University of Otago, New Zealand
| | | | | | | | | |
Collapse
|
99
|
Cavalcanti IMG, Silva WJD, Lucena SCD, Pousa CC, Del Bel Cury AA. Influence of substratum position and acquired pellicle on Candida albicans biofilm. Braz Oral Res 2014; 27:369-75. [PMID: 23780496 DOI: 10.1590/s1806-83242013005000020] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2012] [Accepted: 04/03/2013] [Indexed: 11/22/2022] Open
Abstract
The purpose of this study was to evaluate the influence of the substratum position and the saliva acquired pellicle (AP) on Candida albicans biofilm development. Poly(methylmethacrylate) (PMMA) disks were fabricated and randomly allocated to experimental groups: HNP (disks placed in a horizontal position and uncoated by pellicle), VNP (disks placed in a vertical position and uncoated by pellicle), HCP (disks placed in a horizontal position and coated by pellicle), and VCP (disks placed in a vertical position and coated by pellicle). Disks were placed in a 24-well plate and a suspension of 107 cells/mL of Candida albicans was added to each well for biofilm development. The plates were aerobically incubated at 35°C. The biofilms were evaluated at 1.5 (adhesion time point), 24, 48, 72, and 96 hours. The number of viable cells was quantified in terms of the colony-forming units per milliliter (CFU/mL). Metabolic activity was measured by the XTT assay. The biofilm structure was analyzed by scanning electron microscopy. The data were analyzed by three-way ANOVA followed by Tukey's test, with significance set at 5%. The vertical groups showed less biofilm formation and lower metabolic activity than the horizontal groups (p<0.05). Significant differences in cell viability and metabolic activity were observed between the adhesion and other time points (p<0.05), but these variables were not affected by the presence of the pellicle (p>0.05). It can be concluded that the substratum position influenced biofilm development.
Collapse
Affiliation(s)
- Indira Moraes Gomes Cavalcanti
- Univ of Campinas-UNICAMP, Piracicaba Dental School, Department of Prosthodontics and Periodontology, Piracicaba, SP, Brazil
| | | | | | | | | |
Collapse
|
100
|
Arici N, Ural C. The Effects of a Denture Cleanser on the Surface Roughness of Heat-Cured and Cold-Cured Acrylic Resins. Turk J Orthod 2013. [DOI: 10.13076/j.tjo.2013.26.02_92] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|