51
|
Ge S, Wang Y, Deshler NJ, Preston DJ, Whitesides GM. High-Throughput Density Measurement Using Magnetic Levitation. J Am Chem Soc 2018; 140:7510-7518. [DOI: 10.1021/jacs.8b01283] [Citation(s) in RCA: 33] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
Affiliation(s)
- Shencheng Ge
- Department of Chemistry & Chemical Biology, Harvard University, 12 Oxford Street, Cambridge, Massachusetts 02138, United States
| | - Yunzhe Wang
- Department of Chemistry & Chemical Biology, Harvard University, 12 Oxford Street, Cambridge, Massachusetts 02138, United States
| | - Nicolas J. Deshler
- Department of Chemistry & Chemical Biology, Harvard University, 12 Oxford Street, Cambridge, Massachusetts 02138, United States
| | - Daniel J. Preston
- Department of Chemistry & Chemical Biology, Harvard University, 12 Oxford Street, Cambridge, Massachusetts 02138, United States
| | - George M. Whitesides
- Department of Chemistry & Chemical Biology, Harvard University, 12 Oxford Street, Cambridge, Massachusetts 02138, United States
- Wyss Institute for Biologically Inspired Engineering, Harvard University, 60 Oxford Street, Cambridge, Massachusetts 02138, United States
- Kavli Institute for Bionano Science & Technology, Harvard University, 29 Oxford Street Cambridge, Massachusetts 02138, United States
| |
Collapse
|
52
|
Turker E, Arslan-Yildiz A. Recent Advances in Magnetic Levitation: A Biological Approach from Diagnostics to Tissue Engineering. ACS Biomater Sci Eng 2018; 4:787-799. [DOI: 10.1021/acsbiomaterials.7b00700] [Citation(s) in RCA: 37] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023]
Affiliation(s)
- Esra Turker
- Department of Bioengineering, Izmir Institute of Technology (IZTECH), 35430 Izmir, Turkey
| | - Ahu Arslan-Yildiz
- Department of Bioengineering, Izmir Institute of Technology (IZTECH), 35430 Izmir, Turkey
| |
Collapse
|
53
|
Yang K, Wu J, Peretz-Soroka H, Zhu L, Li Z, Sang Y, Hipolito J, Zhang M, Santos S, Hillier C, de Faria RL, Liu Y, Lin F. M kit: A cell migration assay based on microfluidic device and smartphone. Biosens Bioelectron 2018; 99:259-267. [PMID: 28772229 PMCID: PMC5585005 DOI: 10.1016/j.bios.2017.07.064] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2017] [Revised: 07/15/2017] [Accepted: 07/21/2017] [Indexed: 11/23/2022]
Abstract
Mobile sensing based on the integration of microfluidic device and smartphone, so-called MS2 technology, has enabled many applications over recent years, and continues to stimulate growing interest in both research communities and industries. In particular, it has been envisioned that MS2 technology can be developed for various cell functional assays to enable basic research and clinical applications. Toward this direction, in this paper, we describe the development of a MS2-based cell functional assay for testing cell migration (the Mkit). The system is constructed as an integrated test kit, which includes microfluidic chips, a smartphone-based imaging platform, the phone apps for image capturing and data analysis, and a set of reagent and accessories for performing the cell migration assay. We demonstrated that the Mkit can effectively measure purified neutrophil and cancer cell chemotaxis. Furthermore, neutrophil chemotaxis can be tested from a drop of whole blood using the Mkit with red blood cell (RBC) lysis. The effects of chemoattractant dose and gradient profile on neutrophil chemotaxis were also tested using the Mkit. In addition to research applications, we demonstrated the effective use of the Mkit for on-site test at the hospital and for testing clinical samples from chronic obstructive pulmonary disease patient. Thus, this developed Mkit provides an easy and integrated experimental platform for cell migration related research and potential medical diagnostic applications.
Collapse
Affiliation(s)
- Ke Yang
- Institute of Applied Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui, PR China; Department of Physics and Astronomy, University of Manitoba, Winnipeg, MB, Canada
| | - Jiandong Wu
- Department of Physics and Astronomy, University of Manitoba, Winnipeg, MB, Canada
| | - Hagit Peretz-Soroka
- Department of Physics and Astronomy, University of Manitoba, Winnipeg, MB, Canada
| | - Ling Zhu
- Institute of Applied Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui, PR China
| | - Zhigang Li
- Institute of Applied Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui, PR China
| | - Yaoshuo Sang
- Institute of Applied Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui, PR China
| | - Jolly Hipolito
- Department of Physics and Astronomy, University of Manitoba, Winnipeg, MB, Canada
| | | | - Susy Santos
- Victoria General Hospital and River Heights/Fort Garry Community areas, Winnipeg, MB, Canada
| | | | | | - Yong Liu
- Institute of Applied Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui, PR China
| | - Francis Lin
- Department of Physics and Astronomy, University of Manitoba, Winnipeg, MB, Canada; Department of Biosystems Engineering, University of Manitoba, Winnipeg, MB, Canada; Department of Immunology, University of Manitoba, Winnipeg, MB, Canada; Department of Biological Sciences, University of Manitoba, Winnipeg, MB, Canada.
| |
Collapse
|
54
|
Ansari J, Moufarrej YE, Pawlinski R, Gavins FNE. Sickle cell disease: a malady beyond a hemoglobin defect in cerebrovascular disease. Expert Rev Hematol 2017; 11:45-55. [PMID: 29207881 DOI: 10.1080/17474086.2018.1407240] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
INTRODUCTION Sickle cell disease (SCD) is a devastating monogenic disorder that presents as a multisystem illness and affects approximately 100,000 individuals in the United States alone. SCD management largely focuses on primary prevention, symptomatic treatment and targeting of hemoglobin polymerization and red blood cell sickling. Areas covered: This review will discuss the progress of SCD over the last few decades, highlighting some of the clinical (mainly cerebrovascular) and psychosocial challenges of SCD in the United States. In addition, focus will also be made on the evolving science and management of this inherited disease. Expert commentary: Until recently hydroxyurea (HU) has been the only FDA approved therapy for SCD. However, advancing understanding of SCD pathophysiology has led to multiple clinical trials targeting SCD related thrombo-inflammation, abnormal endothelial biology, increased oxidant stress and sickle cell mutation. Yet, despite advancing understanding, available therapies are limited. SCD also imposes great psychosocial challenges for the individual and the affected community, which has previously been under-recognized. This has created a pressing need for complementary adjuvant therapies with repurposed and novel drugs, in addition to the establishment of comprehensive clinics focusing on both the medical treatment and the psychosocial issues associated with SCD.
Collapse
Affiliation(s)
- Junaid Ansari
- a Department of Molecular and Cellular Physiology , Louisiana State University Health Sciences Center - Shreveport , Shreveport , LA , USA
| | - Youmna E Moufarrej
- b Louisiana State University School of Medicine - Shreveport , Shreveport , LA , USA
| | - Rafal Pawlinski
- c Department of Medicine , University of North Carolina , Chapel Hill , NC , USA
| | - Felicity N E Gavins
- a Department of Molecular and Cellular Physiology , Louisiana State University Health Sciences Center - Shreveport , Shreveport , LA , USA
| |
Collapse
|
55
|
Simultaneous point-of-care detection of anemia and sickle cell disease in Tanzania: the RAPID study. Ann Hematol 2017; 97:239-246. [PMID: 29147848 DOI: 10.1007/s00277-017-3182-8] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2017] [Accepted: 11/09/2017] [Indexed: 12/24/2022]
Abstract
Both anemia and sickle cell disease (SCD) are highly prevalent across sub-Saharan Africa, and limited resources exist to diagnose these conditions quickly and accurately. The development of simple, inexpensive, and accurate point-of-care (POC) assays represents an important advance for global hematology, one that could facilitate timely and life-saving medical interventions. In this prospective study, Robust Assays for Point-of-care Identification of Disease (RAPID), we simultaneously evaluated a POC immunoassay (Sickle SCAN™) to diagnose SCD and a first-generation POC color-based assay to detect anemia. Performed at Bugando Medical Center in Mwanza, Tanzania, RAPID tested 752 participants (age 1 day to 20 years) in four busy clinical locations. With minimally trained medical staff, the SCD POC assay diagnosed SCD with 98.1% sensitivity and 91.1% specificity. The hemoglobin POC assay had 83.2% sensitivity and 74.5% specificity for detection of severe anemia (Hb ≤ 7 g/dL). Interobserver agreement was excellent for both POC assays (r = 0.95-0.96). Results for the hemoglobin POC assay have informed the second-generation assay design to be more suitable for low-resource settings. RAPID provides practical feasibility data regarding two novel POC assays for the diagnosis of anemia and SCD in real-world field evaluations and documents the utility and potential impact of these POC assays for sub-Saharan Africa.
Collapse
|
56
|
Andersen MS, Howard E, Lu S, Richard M, Gregory M, Ogembo G, Mazor O, Gorelik P, Shapiro NI, Sharda AV, Ghiran I. Detection of membrane-bound and soluble antigens by magnetic levitation. LAB ON A CHIP 2017; 17:3462-3473. [PMID: 28905952 PMCID: PMC5642277 DOI: 10.1039/c7lc00402h] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
Magnetic levitation is a technique for measuring the density and the magnetic properties of objects suspended in a paramagnetic field. We describe a novel magnetic levitation-based method that can specifically detect cell membrane-bound and soluble antigens by measurable changes in levitation height that result from the formation of antibody-coated bead and antigen complex. We demonstrate our method's ability to sensitively detect an array of membrane-bound and soluble antigens found in blood, including T-cell antigen CD3, eosinophil antigen Siglec-8, red blood cell antigens CD35 and RhD, red blood cell-bound Epstein-Barr viral particles, and soluble IL-6, and validate the results by flow cytometry and immunofluorescence microscopy performed in parallel. Additionally, employing an inexpensive, single lens, manual focus, wifi-enabled camera, we extend the portability of our method for its potential use as a point-of-care diagnostic assay.
Collapse
Affiliation(s)
- Mikkel Schou Andersen
- Department of Emergency Medicine, Beth Israel Deaconess Medical Center, Harvard Medical School, MA, USA
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
57
|
Lepowsky E, Tasoglu S. 3D printing for drug manufacturing: A perspective on the future of pharmaceuticals. Int J Bioprint 2017; 4:119. [PMID: 33102905 PMCID: PMC7582011 DOI: 10.18063/ijb.v4i1.119] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2017] [Accepted: 09/18/2017] [Indexed: 01/16/2023] Open
Abstract
Since a three-dimensional (3D) printed drug was first approved by the Food and Drug Administration in 2015, there has been a growing interest in 3D printing for drug manufacturing. There are multiple 3D printing methods - including selective laser sintering, binder deposition, stereolithography, inkjet printing, extrusion-based printing, and fused deposition modeling - which are compatible with printing drug products, in addition to both polymer filaments and hydrogels as materials for drug carriers. We see the adaptability of 3D printing as a revolutionary force in the pharmaceutical industry. Release characteristics of drugs may be controlled by complex 3D printed geometries and architectures. Precise and unique doses can be engineered and fabricated via 3D printing according to individual prescriptions. On-demand printing of drug products can be implemented for drugs with limited shelf life or for patient-specific medications, offering an alternative to traditional compounding pharmacies. For these reasons, 3D printing for drug manufacturing is the future of pharmaceuticals, making personalized medicine possible while also transforming pharmacies.
Collapse
Affiliation(s)
- Eric Lepowsky
- Department of Mechanical Engineering, University of Connecticut, Storrs, CT, USA
| | - Savas Tasoglu
- Department of Mechanical Engineering, University of Connecticut, Storrs, CT, USA
- Department of Biomedical Engineering, University of Connecticut, Storrs, CT, USA
- Institute of Materials Science, University of Connecticut, Storrs, CT, USA
- Institute for Collaboration on Health, Intervention, and Policy, University of Connecticut, Storrs, CT, USA
- The Connecticut Institute for the Brain and Cognitive Sciences, University of Connecticut, Storrs, CT, USA
| |
Collapse
|
58
|
Substituting Sodium Hydrosulfite with Sodium Metabisulfite Improves Long-Term Stability of a Distributable Paper-Based Test Kit for Point-of-Care Screening for Sickle Cell Anemia. BIOSENSORS-BASEL 2017; 7:bios7030039. [PMID: 28930183 PMCID: PMC5618045 DOI: 10.3390/bios7030039] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/04/2017] [Revised: 09/13/2017] [Accepted: 09/14/2017] [Indexed: 11/17/2022]
Abstract
Sickle cell anemia (SCA) is a genetic blood disorder that is particularly lethal in early childhood. Universal newborn screening programs and subsequent early treatment are known to drastically reduce under-five SCA mortality. However, in resource-limited settings, cost and infrastructure constraints limit the effectiveness of laboratory-based SCA screening programs. To address this limitation our laboratory previously developed a low-cost, equipment-free, point-of-care, paper-based SCA test. Here, we improved the stability and performance of the test by replacing sodium hydrosulfite (HS), a key reducing agent in the hemoglobin solubility buffer which is not stable in aqueous solutions, with sodium metabisulfite (MS). The MS formulation of the test was compared to the HS formulation in a laboratory setting by inexperienced users (n = 3), to determine visual limit of detection (LOD), readout time, diagnostic accuracy, intra- and inter-observer agreement, and shelf life. The MS test was found to have a 10% sickle hemoglobin LOD, 21-min readout time, 97.3% sensitivity and 99.5% specificity for SCA, almost perfect intra- and inter-observer agreement, at least 24 weeks of shelf stability at room temperature, and could be packaged into a self-contained, distributable test kits comprised of off-the-shelf disposable components and food-grade reagents with a total cost of only $0.21 (USD).
Collapse
|
59
|
Chan HN, Tan MJA, Wu H. Point-of-care testing: applications of 3D printing. LAB ON A CHIP 2017; 17:2713-2739. [PMID: 28702608 DOI: 10.1039/c7lc00397h] [Citation(s) in RCA: 74] [Impact Index Per Article: 10.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
Point-of-care testing (POCT) devices fulfil a critical need in the modern healthcare ecosystem, enabling the decentralized delivery of imperative clinical strategies in both developed and developing worlds. To achieve diagnostic utility and clinical impact, POCT technologies are immensely dependent on effective translation from academic laboratories out to real-world deployment. However, the current research and development pipeline is highly bottlenecked owing to multiple restraints in material, cost, and complexity of conventionally available fabrication techniques. Recently, 3D printing technology has emerged as a revolutionary, industry-compatible method enabling cost-effective, facile, and rapid manufacturing of objects. This has allowed iterative design-build-test cycles of various things, from microfluidic chips to smartphone interfaces, that are geared towards point-of-care applications. In this review, we focus on highlighting recent works that exploit 3D printing in developing POCT devices, underscoring its utility in all analytical steps. Moreover, we also discuss key advantages of adopting 3D printing in the device development pipeline and identify promising opportunities in 3D printing technology that can benefit global health applications.
Collapse
Affiliation(s)
- Ho Nam Chan
- Department of Chemistry, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong, China.
| | | | | |
Collapse
|
60
|
McGann PT, Hoppe C. The pressing need for point-of-care diagnostics for sickle cell disease: A review of current and future technologies. Blood Cells Mol Dis 2017; 67:104-113. [PMID: 28844459 DOI: 10.1016/j.bcmd.2017.08.010] [Citation(s) in RCA: 38] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2016] [Accepted: 08/07/2017] [Indexed: 10/19/2022]
Abstract
Sickle cell disease (SCD) is a common and life threatening inherited blood disorder, affecting over 300,000 newborns per year. Over 75% of SCD births occur in sub-Saharan Africa, where the lack of timely and accurate diagnosis results in premature death within the first few years of life for a majority of affected infants. Current methods to diagnosis SCD require expensive laboratory equipment and reagents, and adequately trained laboratory personnel. In addition, test results are often delayed due to transport and batching of samples in a central laboratory. Financial and technical limitations often preclude any form of SCD laboratory testing at the local level in regions where SCD is most prevalent. There has been a recent surge of interest in addressing the global burden of SCD, including improving and optimizing diagnostic capacities. Largely stimulated by a funding opportunity from the NIH, several point-of-care diagnostics have been developed for SCD with a focus on developing devices that are inexpensive, simple, and practical in limited resource settings. In this manuscript, we review the global burden of SCA, including the rationale for the development of POC assays, and carefully review the POC devices currently in development.
Collapse
Affiliation(s)
- Patrick T McGann
- Division of Hematology, Cincinnati Children's Hospital Medical Center, Cincinnati, OH, USA.
| | - Carolyn Hoppe
- UCSF Benioff Children's Hospital Oakland, Oakland, CA, USA
| |
Collapse
|
61
|
Knowlton S, Joshi A, Syrrist P, Coskun AF, Tasoglu S. 3D-printed smartphone-based point of care tool for fluorescence- and magnetophoresis-based cytometry. LAB ON A CHIP 2017; 17:2839-2851. [PMID: 28726914 DOI: 10.1039/c7lc00706j] [Citation(s) in RCA: 66] [Impact Index Per Article: 9.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/18/2023]
Abstract
In developing countries, there are often limited resources available to provide important medical diagnostics, which severely limits our ability to diagnose conditions and administer proper treatment, leading to high mortality rates for treatable conditions. Here, we propose a multiplex tool capable of density-based cell sorting via magnetic focusing in parallel with fluorescence imaging to provide highly specific clinical assays. While many cell sorting techniques and fluorescence microscopes generally are costly and require extensive user training, limiting accessibility and usability in developing countries, this device is compact, low-cost, and portable. The device can separate cells on the basis of density, which can be used to identify cell type and cell activity, and image the cells in either brightfield, darkfield, or fluorescent imaging modes using the built-in smartphone camera. The combination of these two powerful and versatile techniques - magnetic focusing and fluorescence imaging - will make this platform broadly applicable to a range of biomedical assays. Clinical applications include cell cytometry and immunocytochemistry-based assays in limited-resource settings, which can ultimately help to improve worldwide accessibility to medical diagnostics.
Collapse
Affiliation(s)
- Stephanie Knowlton
- Department of Biomedical Engineering, University of Connecticut, Storrs, CT 06269, USA.
| | | | | | | | | |
Collapse
|
62
|
Kim B, Lee YJ, Park JG, Yoo D, Hahn YK, Choi S. A portable somatic cell counter based on a multi-functional counting chamber and a miniaturized fluorescence microscope. Talanta 2017; 170:238-243. [DOI: 10.1016/j.talanta.2017.04.014] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2017] [Revised: 04/06/2017] [Accepted: 04/07/2017] [Indexed: 10/19/2022]
|
63
|
Kim M, Alapan Y, Adhikari A, Little JA, Gurkan UA. Hypoxia-enhanced adhesion of red blood cells in microscale flow. Microcirculation 2017; 24:10.1111/micc.12374. [PMID: 28387057 PMCID: PMC5679205 DOI: 10.1111/micc.12374] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2016] [Accepted: 04/03/2017] [Indexed: 12/12/2022]
Abstract
OBJECTIVES The advancement of microfluidic technology has facilitated the simulation of physiological conditions of the microcirculation, such as oxygen tension, fluid flow, and shear stress in these devices. Here, we present a micro-gas exchanger integrated with microfluidics to study RBC adhesion under hypoxic flow conditions mimicking postcapillary venules. METHODS We simulated a range of physiological conditions and explored RBC adhesion to endothelial or subendothelial components (FN or LN). Blood samples were injected into microchannels at normoxic or hypoxic physiological flow conditions. Quantitative evaluation of RBC adhesion was performed on 35 subjects with homozygous SCD. RESULTS Significant heterogeneity in RBC adherence response to hypoxia was seen among SCD patients. RBCs from a HEA population showed a significantly greater increase in adhesion compared to RBCs from a HNA population, for both FN and LN. CONCLUSIONS The approach presented here enabled the control of oxygen tension in blood during microscale flow and the quantification of RBC adhesion in a cost-efficient and patient-specific manner. We identified a unique patient population in which RBCs showed enhanced adhesion in hypoxia in vitro. Clinical correlates suggest a more severe clinical phenotype in this subgroup.
Collapse
Affiliation(s)
- Myeongseop Kim
- Case Biomanufacturing and Microfabrication Laboratory, Mechanical and Aerospace Engineering Department, Case Western Reserve University, Cleveland, OH, USA
| | - Yunus Alapan
- Case Biomanufacturing and Microfabrication Laboratory, Mechanical and Aerospace Engineering Department, Case Western Reserve University, Cleveland, OH, USA
- Physical Intelligence Department, Max Planck Institute for Intelligent Systems, Stuttgart, Germany
| | - Anima Adhikari
- Case Biomanufacturing and Microfabrication Laboratory, Mechanical and Aerospace Engineering Department, Case Western Reserve University, Cleveland, OH, USA
| | - Jane A. Little
- Department of Hematology and Oncology, School of Medicine, Case Western Reserve University, Cleveland, OH, USA
- Seidman Cancer Center at University Hospitals Cleveland Medical Center, Cleveland, OH, USA
| | - Umut A. Gurkan
- Case Biomanufacturing and Microfabrication Laboratory, Mechanical and Aerospace Engineering Department, Case Western Reserve University, Cleveland, OH, USA
- Department of Hematology and Oncology, School of Medicine, Case Western Reserve University, Cleveland, OH, USA
- Biomedical Engineering Department, Case Western Reserve University, Cleveland, OH, USA
- Department of Orthopaedics, Case Western Reserve University, Cleveland, OH, USA
| |
Collapse
|
64
|
Amin R, Knowlton S, Dupont J, Bergholz JS, Joshi A, Hart A, Yenilmez B, Yu CH, Wentworth A, Zhao JJ, Tasoglu S. 3D-printed smartphone-based device for label-free cell separation. ACTA ACUST UNITED AC 2017. [DOI: 10.2217/3dp-2016-0007] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Aim: To assess several fabrication metrics of a 3D-printed smartphone-attachable continuous-flow magnetic focusing device for real-time separation and detection of different cell types based on their volumetric mass density in high-volume samples. Method: The smartphone apparatus has been designed and fabricated using three different 3D printing method. Several 3D printing metrics including cost, printing time, and resolution have been evaluated to propose a cost-efficient and high-performance platform for low-resource settings. Results: To apply the magnetic focusing technique on large sample volumes, a heterogeneous mixture of sample (e.g., containing blood cells and cancer cells) suspended in paramagnetic medium is pumped through a magnetic field at an optimum flow rate. The performance of the 3D-printed device has been investigated by demonstrating separation of microspheres, breast, lung, ovarian and prostate cancer cells mixed with blood cells. The separation distance of cancer and blood cells is around 100 μm, allowing the two cell types to be easily distinguished. Conclusion: This device could be useful for clinical centers in low-income countries where expensive infrastructure, equipment (e.g., FACS) and technical expertise are lacking. This device could ultimately be applied to rare cell separation and purification.
Collapse
Affiliation(s)
- Reza Amin
- Department of Mechanical Engineering, University of Connecticut, Storrs, CT 06269, USA
| | - Stephanie Knowlton
- Department of Biomedical Engineering, University of Connecticut, Storrs, CT 06269, USA
| | - Joshua Dupont
- Department of Mechanical Engineering, University of Connecticut, Storrs, CT 06269, USA
| | - Johann S Bergholz
- Department of Cancer Biology, Dana-Farber Cancer Institute, Boston, MA 02215, USA; Department of Biological Chemistry and Molecular Pharmacology, Harvard Medical School, Boston, MA 02115, USA
| | - Ashwini Joshi
- Department of Biomedical Engineering, University of Connecticut, Storrs, CT 06269, USA
| | - Alexander Hart
- Department of Biomedical Engineering, University of Connecticut, Storrs, CT 06269, USA
| | - Bekir Yenilmez
- Department of Mechanical Engineering, University of Connecticut, Storrs, CT 06269, USA
| | - Chu Hsiang Yu
- Department of Mechanical Engineering, University of Connecticut, Storrs, CT 06269, USA
| | - Adam Wentworth
- Institute of Materials Science, University of Connecticut, Storrs, CT 06269, USA
| | - Jean J Zhao
- Department of Cancer Biology, Dana-Farber Cancer Institute, Boston, MA 02215, USA; Department of Biological Chemistry and Molecular Pharmacology, Harvard Medical School, Boston, MA 02115, USA
| | - Savas Tasoglu
- Department of Mechanical Engineering, University of Connecticut, Storrs, CT 06269, USA
- Department of Biomedical Engineering, University of Connecticut, Storrs, CT 06269, USA
- Institute of Materials Science, University of Connecticut, Storrs, CT 06269, USA
- Institute for Collaboration on Health, Intervention, & Policy, University of Connecticut, Storrs, CT 06269, USA
| |
Collapse
|
65
|
Zhao W, Cheng R, Lim SH, Miller JR, Zhang W, Tang W, Xie J, Mao L. Biocompatible and label-free separation of cancer cells from cell culture lines from white blood cells in ferrofluids. LAB ON A CHIP 2017; 17:2243-2255. [PMID: 28590489 PMCID: PMC5543773 DOI: 10.1039/c7lc00327g] [Citation(s) in RCA: 38] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
This paper reports a biocompatible and label-free cell separation method using ferrofluids that can separate a variety of low-concentration cancer cells from cell culture lines (∼100 cancer cells per mL) from undiluted white blood cells, with a throughput of 1.2 mL h-1 and an average separation efficiency of 82.2%. The separation is based on the size difference of the cancer cells and white blood cells, and is conducted in a custom-made biocompatible ferrofluid that retains not only excellent short-term viabilities but also normal proliferations of 7 commonly used cancer cell lines. A microfluidic device is designed and optimized specifically to shorten the time of live cells' exposure to ferrofluids from hours to seconds, by eliminating time-consuming off-chip sample preparation and extraction steps and integrating them on-chip to achieve a one-step process. As a proof-of-concept demonstration, a ferrofluid with 0.26% volume fraction was used in this microfluidic device to separate spiked cancer cells from cell lines at a concentration of ∼100 cells per mL from white blood cells with a throughput of 1.2 mL h-1. The separation efficiencies were 80 ± 3%, 81 ± 5%, 82 ± 5%, 82 ± 4%, and 86 ± 6% for A549 lung cancer, H1299 lung cancer, MCF-7 breast cancer, MDA-MB-231 breast cancer, and PC-3 prostate cancer cell lines, respectively. The separated cancer cells' purity was between 25.3% and 28.8%. In addition, the separated cancer cells from this strategy showed an average short-term viability of 94.4 ± 1.3%, and these separated cells were cultured and demonstrated normal proliferation to confluence even after the separation process. Owing to its excellent biocompatibility and label-free operation and its ability to recover low concentrations of cancer cells from white blood cells, this method could lead to a promising tool for rare cell separation.
Collapse
Affiliation(s)
- Wujun Zhao
- Department of Chemistry, University of Georgia, Athens, Georgia 30602, USA
| | | | | | | | | | | | | | | |
Collapse
|
66
|
A Paper-Based Test for Screening Newborns for Sickle Cell Disease. Sci Rep 2017; 7:45488. [PMID: 28367971 PMCID: PMC5377336 DOI: 10.1038/srep45488] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2016] [Accepted: 02/28/2017] [Indexed: 11/28/2022] Open
Abstract
The high cost, complexity and reliance on electricity, specialized equipment and supplies associated with conventional diagnostic methods limit the scope and sustainability of newborn screening for sickle cell disease (SCD) in sub-Saharan Africa and other resource-limited areas worldwide. Here we describe the development of a simple, low-cost, rapid, equipment- and electricity-free paper-based test capable of detecting sickle hemoglobin (HbS) in newborn blood samples with a limit of detection of 2% HbS. We validated this newborn paper-based test in a cohort of 159 newborns at an obstetric hospital in Cabinda, Angola. Newborn screening results using the paper-based test were compared to conventional isoelectric focusing (IEF). The test detected the presence of HbS with 81.8% sensitivity and 83.3% specificity, and identified SCD newborns with 100.0% sensitivity and 70.7% specificity. The use of the paper-based test in a two-stage newborn screening process could have excluded about 70% of all newborns from expensive confirmatory testing by IEF, without missing any of the SCD newborns in the studied cohort. This study demonstrates the potential utility of the newborn paper-based test for reducing the overall cost of screening newborns for SCD and thus increasing the practicality of universal newborn SCD screening programs in resource-limited settings.
Collapse
|
67
|
Amin R, Joshi A, Tasoglu S. Commercialization of 3D-printed microfluidic devices. ACTA ACUST UNITED AC 2017. [DOI: 10.2217/3dp-2016-0010] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Affiliation(s)
- Reza Amin
- Department of Mechanical Engineering, University of Connecticut, Storrs, CT 06269, USA
| | - Ashwini Joshi
- Department of Biomedical Engineering, University of Connecticut, Storrs, CT 06269, USA
| | - Savas Tasoglu
- Department of Mechanical Engineering, University of Connecticut, Storrs, CT 06269, USA
- Department of Biomedical Engineering, University of Connecticut, Storrs, CT 06269, USA
| |
Collapse
|
68
|
Knowlton SM, Yenilmez B, Amin R, Tasoglu S. Magnetic Levitation Coupled with Portable Imaging and Analysis for Disease Diagnostics. J Vis Exp 2017. [PMID: 28287511 DOI: 10.3791/55012] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/31/2022] Open
Abstract
Currently, many clinical diagnostic procedures are complex, costly, inefficient, and inaccessible to a large population in the world. The requirements for specialized equipment and trained personnel require that many diagnostic tests be performed at remote, centralized clinical laboratories. Magnetic levitation is a simple yet powerful technique and can be applied to levitate cells, which are suspended in a paramagnetic solution and placed in a magnetic field, at a position determined by equilibrium between a magnetic force and a buoyancy force. Here, we present a versatile platform technology designed for point-of-care diagnostics which uses magnetic levitation coupled to microscopic imaging and automated analysis to determine the density distribution of a patient's cells as a useful diagnostic indicator. We present two platforms operating on this principle: (i) a smartphone-compatible version of the technology, where the built-in smartphone camera is used to image cells in the magnetic field and a smartphone application processes the images and to measures the density distribution of the cells and (ii) a self-contained version where a camera board is used to capture images and an embedded processing unit with attached thin-film-transistor (TFT) screen measures and displays the results. Demonstrated applications include: (i) measuring the altered distribution of a cell population with a disease phenotype compared to a healthy phenotype, which is applied to sickle cell disease diagnosis, and (ii) separation of different cell types based on their characteristic densities, which is applied to separate white blood cells from red blood cells for white blood cell cytometry. These applications, as well as future extensions of the essential density-based measurements enabled by this portable, user-friendly platform technology, will significantly enhance disease diagnostic capabilities at the point of care.
Collapse
Affiliation(s)
| | - Bekir Yenilmez
- Mechanical Engineering Department, University of Connecticut
| | - Reza Amin
- Mechanical Engineering Department, University of Connecticut
| | - Savas Tasoglu
- Biomedical Engineering Department, University of Connecticut; Mechanical Engineering Department, University of Connecticut;
| |
Collapse
|
69
|
Roda A, Calabretta MM, Calabria D, Caliceti C, Cevenini L, Lopreside A, Zangheri M. Smartphone-Based Biosensors for Bioanalytics. PAST, PRESENT AND FUTURE CHALLENGES OF BIOSENSORS AND BIOANALYTICAL TOOLS IN ANALYTICAL CHEMISTRY: A TRIBUTE TO PROFESSOR MARCO MASCINI 2017. [DOI: 10.1016/bs.coac.2017.05.007] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
70
|
|
71
|
Ultra-portable, wireless smartphone spectrometer for rapid, non-destructive testing of fruit ripeness. Sci Rep 2016; 6:32504. [PMID: 27606927 PMCID: PMC5015488 DOI: 10.1038/srep32504] [Citation(s) in RCA: 112] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2016] [Accepted: 08/10/2016] [Indexed: 12/12/2022] Open
Abstract
We demonstrate a smartphone based spectrometer design that is standalone and supported on a wireless platform. The device is inherently low-cost and the power consumption is minimal making it portable to carry out a range of studies in the field. All essential components of the device like the light source, spectrometer, filters, microcontroller and wireless circuits have been assembled in a housing of dimensions 88 mm × 37 mm × 22 mm and the entire device weighs 48 g. The resolution of the spectrometer is 15 nm, delivering accurate and repeatable measurements. The device has a dedicated app interface on the smartphone to communicate, receive, plot and analyze spectral data. The performance of the smartphone spectrometer is comparable to existing bench-top spectrometers in terms of stability and wavelength resolution. Validations of the device were carried out by demonstrating non-destructive ripeness testing in fruit samples. Ultra-Violet (UV) fluorescence from Chlorophyll present in the skin was measured across various apple varieties during the ripening process and correlated with destructive firmness tests. A satisfactory agreement was observed between ripeness and fluorescence signals. This demonstration is a step towards possible consumer, bio-sensing and diagnostic applications that can be carried out in a rapid manner.
Collapse
|
72
|
Hejazian M, Nguyen NT. Magnetofluidic concentration and separation of non-magnetic particles using two magnet arrays. BIOMICROFLUIDICS 2016; 10:044103. [PMID: 27478527 PMCID: PMC4947043 DOI: 10.1063/1.4955421] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/24/2016] [Accepted: 06/24/2016] [Indexed: 05/11/2023]
Abstract
The present paper reports the use of diluted ferrofluid and two arrays of permanent magnets for the size-selective concentration of non-magnetic particles. The micro magnetofluidic device consists of a straight channels sandwiched between two arrays of permanent magnets. The permanent magnets create multiple capture zones with minimum magnetic field strength along the channel. The complex interaction between magnetic forces and hydrodynamic force allows the device to operate in different regimes suitable for concentration of non-magnetic particles with small difference in size. Our experimental results show that non-magnetic particles with diameters of 3.1 μm and 4.8 μm can be discriminated and separated with this method. The results from this study could be used as a guide for the design of size-sensitive separation devices for particle and cell based on negative magnetophoresis.
Collapse
Affiliation(s)
- Majid Hejazian
- Queensland Micro and Nanotechnology Centre, Griffith University , Brisbane, Queensland 4111, Australia
| | - Nam-Trung Nguyen
- Queensland Micro and Nanotechnology Centre, Griffith University , Brisbane, Queensland 4111, Australia
| |
Collapse
|
73
|
Knowlton S, Yu CH, Ersoy F, Emadi S, Khademhosseini A, Tasoglu S. 3D-printed microfluidic chips with patterned, cell-laden hydrogel constructs. Biofabrication 2016; 8:025019. [DOI: 10.1088/1758-5090/8/2/025019] [Citation(s) in RCA: 93] [Impact Index Per Article: 11.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
|
74
|
Amin R, Knowlton S, Hart A, Yenilmez B, Ghaderinezhad F, Katebifar S, Messina M, Khademhosseini A, Tasoglu S. 3D-printed microfluidic devices. Biofabrication 2016; 8:022001. [DOI: 10.1088/1758-5090/8/2/022001] [Citation(s) in RCA: 208] [Impact Index Per Article: 26.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
|
75
|
Zhao W, Cheng R, Miller JR, Mao L. Label-Free Microfluidic Manipulation of Particles and Cells in Magnetic Liquids. ADVANCED FUNCTIONAL MATERIALS 2016; 26:3916-3932. [PMID: 28663720 PMCID: PMC5487005 DOI: 10.1002/adfm.201504178] [Citation(s) in RCA: 81] [Impact Index Per Article: 10.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
Manipulating particles and cells in magnetic liquids through so-called "negative magnetophoresis" is a new research field. It has resulted in label-free and low-cost manipulation techniques in microfluidic systems and many exciting applications. It is the goal of this review to introduce the fundamental principles of negative magnetophoresis and its recent applications in microfluidic manipulation of particles and cells. We will first discuss the theoretical background of three commonly used specificities of manipulation in magnetic liquids, which include the size, density and magnetic property of particles and cells. We will then review and compare the media used in negative magnetophoresis, which include paramagnetic salt solutions and ferrofluids. Afterwards, we will focus on reviewing existing microfluidic applications of negative magnetophoresis, including separation, focusing, trapping and concentration of particles and cells, determination of cell density, measurement of particles' magnetic susceptibility, and others. We will also examine the need for developing biocompatible magnetic liquids for live cell manipulation and analysis, and its recent progress. Finally, we will conclude this review with a brief outlook for this exciting research field.
Collapse
Affiliation(s)
- Wujun Zhao
- Department of Chemistry, The University of Georgia, Athens, Georgia 30602, USA
| | - Rui Cheng
- College of Engineering, The University of Georgia, 220 Riverbend Road, Room 166, Athens, Georgia 30602, USA
| | - Joshua R Miller
- Department of Chemistry, The University of Georgia, Athens, Georgia 30602, USA
| | - Leidong Mao
- College of Engineering, The University of Georgia, 220 Riverbend Road, Room 166, Athens, Georgia 30602, USA
| |
Collapse
|
76
|
Arts R, den Hartog I, Zijlema SE, Thijssen V, van der Beelen SHE, Merkx M. Detection of Antibodies in Blood Plasma Using Bioluminescent Sensor Proteins and a Smartphone. Anal Chem 2016; 88:4525-32. [PMID: 27018236 DOI: 10.1021/acs.analchem.6b00534] [Citation(s) in RCA: 99] [Impact Index Per Article: 12.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Antibody detection is of fundamental importance in many diagnostic and bioanalytical assays, yet current detection techniques tend to be laborious and/or expensive. We present a new sensor platform (LUMABS) based on bioluminescence resonance energy transfer (BRET) that allows detection of antibodies directly in solution using a smartphone as the sole piece of equipment. LUMABS are single-protein sensors that consist of the blue-light emitting luciferase NanoLuc connected via a semiflexible linker to the green fluorescent acceptor protein mNeonGreen, which are kept close together using helper domains. Binding of an antibody to epitope sequences flanking the linker disrupts the interaction between the helper domains, resulting in a large decrease in BRET efficiency. The resulting change in color of the emitted light from green-blue to blue can be detected directly in blood plasma, even at picomolar concentrations of antibody. Moreover, the modular architecture of LUMABS allows changing of target specificity by simple exchange of epitope sequences, as demonstrated here for antibodies against HIV1-p17, hemagglutinin (HA), and dengue virus type I. The combination of sensitive ratiometric bioluminescent detection and the intrinsic modularity of the LUMABS design provides an attractive generic platform for point-of-care antibody detection that avoids the complex liquid handling steps associated with conventional immunoassays.
Collapse
Affiliation(s)
- Remco Arts
- Laboratory of Chemical Biology and Institute for Complex Molecular Systems, Department of Biomedical Engineering, Eindhoven University of Technology , P.O. Box 513, 5600 MB Eindhoven, The Netherlands
| | - Ilona den Hartog
- Laboratory of Chemical Biology and Institute for Complex Molecular Systems, Department of Biomedical Engineering, Eindhoven University of Technology , P.O. Box 513, 5600 MB Eindhoven, The Netherlands
| | - Stefan E Zijlema
- Laboratory of Chemical Biology and Institute for Complex Molecular Systems, Department of Biomedical Engineering, Eindhoven University of Technology , P.O. Box 513, 5600 MB Eindhoven, The Netherlands
| | - Vito Thijssen
- Laboratory of Chemical Biology and Institute for Complex Molecular Systems, Department of Biomedical Engineering, Eindhoven University of Technology , P.O. Box 513, 5600 MB Eindhoven, The Netherlands
| | - Stan H E van der Beelen
- Laboratory of Chemical Biology and Institute for Complex Molecular Systems, Department of Biomedical Engineering, Eindhoven University of Technology , P.O. Box 513, 5600 MB Eindhoven, The Netherlands
| | - Maarten Merkx
- Laboratory of Chemical Biology and Institute for Complex Molecular Systems, Department of Biomedical Engineering, Eindhoven University of Technology , P.O. Box 513, 5600 MB Eindhoven, The Netherlands
| |
Collapse
|
77
|
Amin R, Knowlton S, Yenilmez B, Hart A, Joshi A, Tasoglu S. Smart-phone attachable, flow-assisted magnetic focusing device. RSC Adv 2016. [DOI: 10.1039/c6ra19483d] [Citation(s) in RCA: 35] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023] Open
Abstract
We present a smart-phone attachable continuous flow magnetic focusing device as an inexpensive and portable tool for real-time detection, monitoring, and sorting of particles in high-volume samples based on their volumetric mass density.
Collapse
Affiliation(s)
- Reza Amin
- Department of Mechanical Engineering
- University of Connecticut
- USA
| | | | - Bekir Yenilmez
- Department of Mechanical Engineering
- University of Connecticut
- USA
| | - Alexander Hart
- Department of Biomedical Engineering
- University of Connecticut
- USA
| | - Ashwini Joshi
- Department of Biomedical Engineering
- University of Connecticut
- USA
| | - Savas Tasoglu
- Department of Mechanical Engineering
- University of Connecticut
- USA
- Department of Biomedical Engineering
- University of Connecticut
| |
Collapse
|