51
|
Horn DL, Dudley DJ, Dedhia K, Nie K, Drennan WR, Won JH, Rubinstein JT, Werner LA. Effects of age and hearing mechanism on spectral resolution in normal hearing and cochlear-implanted listeners. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2017; 141:613. [PMID: 28147578 PMCID: PMC5848837 DOI: 10.1121/1.4974203] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/02/2016] [Revised: 12/21/2016] [Accepted: 01/04/2017] [Indexed: 05/26/2023]
Abstract
Spectral resolution limits speech perception with a cochlear implant (CI) in post-lingually deaf adults. However, the development of spectral resolution in pre-lingually deaf implanted children is not well understood. Acoustic spectral resolution was measured as a function of age (school-age versus adult) in CI and normal-hearing (NH) participants using spectral ripple discrimination (SRD). A 3-alternative forced-choice task was used to obtain SRD thresholds at five ripple depths. Effects of age and hearing method on SRD and spectral modulation transfer function (SMTF) slope (reflecting frequency resolution) and x-intercept (reflecting across-channel intensity resolution) were examined. Correlations between SRD, SMTF parameters, age, and speech perception in noise were studied. Better SRD in NH than CI participants was observed at all depths. SRD thresholds and SMTF slope correlated with speech perception in CI users. When adjusted for floor performance, x-intercept did not correlate with SMTF slope or speech perception. Age and x-intercept correlations were positive and significant in NH but not CI children suggesting that across-channel intensity resolution matures during school-age in NH children. No evidence for maturation of spectral resolution beyond early school-age in pre-lingually deaf implanted CI users was found in the present study.
Collapse
Affiliation(s)
- David L Horn
- Department of Otolaryngology-Head and Neck Surgery, Virginia Merrill Bloedel Hearing Research Center, University of Washington, Box 357923, Seattle, Washington 98195, USA
| | - Daniel J Dudley
- Department of Otolaryngology-Head and Neck Surgery, Virginia Merrill Bloedel Hearing Research Center, University of Washington, Box 357923, Seattle, Washington 98195, USA
| | - Kavita Dedhia
- Department of Otolaryngology-Head and Neck Surgery, Virginia Merrill Bloedel Hearing Research Center, University of Washington, Box 357923, Seattle, Washington 98195, USA
| | - Kaibao Nie
- School of Science, Technology, Engineering and Mathematics, University of Washington, Bothell, Washington 98011, USA
| | - Ward R Drennan
- Department of Otolaryngology-Head and Neck Surgery, Virginia Merrill Bloedel Hearing Research Center, University of Washington, Box 357923, Seattle, Washington 98195, USA
| | - Jong Ho Won
- Department of Otolaryngology-Head and Neck Surgery, Virginia Merrill Bloedel Hearing Research Center, University of Washington, Box 357923, Seattle, Washington 98195, USA
| | - Jay T Rubinstein
- Department of Otolaryngology-Head and Neck Surgery, Virginia Merrill Bloedel Hearing Research Center, University of Washington, Box 357923, Seattle, Washington 98195, USA
| | - Lynne A Werner
- Department of Speech and Hearing Sciences, University of Washington, Seattle, Washington 98195, USA
| |
Collapse
|
52
|
Narne VK, Sharma M, Van Dun B, Bansal S, Prabhu L, Moore BCJ. Effects of spectral smearing on performance of the spectral ripple and spectro-temporal ripple tests. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2016; 140:4298-4306. [DOI: 10.1121/1.4971419] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
|
53
|
Choi JE, Hong SH, Won JH, Park HS, Cho YS, Chung WH, Cho YS, Moon IJ. Evaluation of Cochlear Implant Candidates using a Non-linguistic Spectrotemporal Modulation Detection Test. Sci Rep 2016; 6:35235. [PMID: 27731425 PMCID: PMC5059668 DOI: 10.1038/srep35235] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2016] [Accepted: 09/22/2016] [Indexed: 11/26/2022] Open
Abstract
Adults who score 50% correct or less in open-set sentence recognition test under the best aided listening condition may be considered as candidates for cochlear implant (CI). However, the requirement for ‘the best aided listening condition’ needs significant time and clinical resources to ensure such condition. As speech signals are composed of dynamic spectral and temporal modulations, psychoacoustic sensitivity to the combinations of spectral and temporal modulation cues may be a strong predictor for aided speech recognition. In this study, we tested 27 adults with moderately severe to profound hearing loss to explore the possibility that a non-linguistic unaided spectrotemporal modulation (STM) detection test might be a viable option as a surrogate measure to evaluate CI candidacy. Our results showed that STM detection thresholds were significantly correlated with aided sentence recognition scores for the 27 hearing impaired listeners. The receiver operator characteristic (ROC) curve analysis demonstrated that the CI candidacy evaluation by both unaided STM detection test and the traditional best-aided sentence recognition test was fairly consistent. More specifically, our results demonstrated that the STM detection test using a low spectral and temporal modulation rate might provide an efficient process for CI candidacy evaluation.
Collapse
Affiliation(s)
- Ji Eun Choi
- Department of Otorhinolaryngology - Head and Neck Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
| | - Sung Hwa Hong
- Department of Otorhinolaryngology - Head and Neck Surgery, Samsung Changwon Hospital, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
| | - Jong Ho Won
- Division of Ophthalmic and Ear, Nose and Throat Devices, Office of Device Evaluation, Center for Devices and Radiological Health, US Food and Drug Administration, Silver Spring 20993, Maryland, USA
| | - Hee-Sung Park
- Department of Otorhinolaryngology - Head and Neck Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
| | - Young Sang Cho
- Department of Otorhinolaryngology - Head and Neck Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
| | - Won-Ho Chung
- Department of Otorhinolaryngology - Head and Neck Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
| | - Yang-Sun Cho
- Department of Otorhinolaryngology - Head and Neck Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
| | - Il Joon Moon
- Department of Otorhinolaryngology - Head and Neck Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
| |
Collapse
|
54
|
Barlow N, Purdy SC, Sharma M, Giles E, Narne V. The Effect of Short-Term Auditory Training on Speech in Noise Perception and Cortical Auditory Evoked Potentials in Adults with Cochlear Implants. Semin Hear 2016; 37:84-98. [PMID: 27587925 DOI: 10.1055/s-0035-1570335] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022] Open
Abstract
This study investigated whether a short intensive psychophysical auditory training program is associated with speech perception benefits and changes in cortical auditory evoked potentials (CAEPs) in adult cochlear implant (CI) users. Ten adult implant recipients trained approximately 7 hours on psychophysical tasks (Gap-in-Noise Detection, Frequency Discrimination, Spectral Rippled Noise [SRN], Iterated Rippled Noise, Temporal Modulation). Speech performance was assessed before and after training using Lexical Neighborhood Test (LNT) words in quiet and in eight-speaker babble. CAEPs evoked by a natural speech stimulus /baba/ with varying syllable stress were assessed pre- and post-training, in quiet and in noise. SRN psychophysical thresholds showed a significant improvement (78% on average) over the training period, but performance on other psychophysical tasks did not change. LNT scores in noise improved significantly post-training by 11% on average compared with three pretraining baseline measures. N1P2 amplitude changed post-training for /baba/ in quiet (p = 0.005, visit 3 pretraining versus visit 4 post-training). CAEP changes did not correlate with behavioral measures. CI recipients' clinical records indicated a plateau in speech perception performance prior to participation in the study. A short period of intensive psychophysical training produced small but significant gains in speech perception in noise and spectral discrimination ability. There remain questions about the most appropriate type of training and the duration or dosage of training that provides the most robust outcomes for adults with CIs.
Collapse
Affiliation(s)
- Nathan Barlow
- School of Psychology, University of Auckland, New Zealand
| | | | - Mridula Sharma
- Department of Linguistics, Macquarie University and HEARing CRC, NSW, Australia
| | - Ellen Giles
- Adult Northern Cochlear Implant Programme, University of Auckland, New Zealand
| | - Vijay Narne
- All India Institute of Speech and Hearing, University of Mysore, Mysuru, Karnataka, India
| |
Collapse
|
55
|
Won JH, Moon IJ, Jin S, Park H, Woo J, Cho YS, Chung WH, Hong SH. Spectrotemporal Modulation Detection and Speech Perception by Cochlear Implant Users. PLoS One 2015; 10:e0140920. [PMID: 26485715 PMCID: PMC4617902 DOI: 10.1371/journal.pone.0140920] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2015] [Accepted: 10/01/2015] [Indexed: 11/18/2022] Open
Abstract
Spectrotemporal modulation (STM) detection performance was examined for cochlear implant (CI) users. The test involved discriminating between an unmodulated steady noise and a modulated stimulus. The modulated stimulus presents frequency modulation patterns that change in frequency over time. In order to examine STM detection performance for different modulation conditions, two different temporal modulation rates (5 and 10 Hz) and three different spectral modulation densities (0.5, 1.0, and 2.0 cycles/octave) were employed, producing a total 6 different STM stimulus conditions. In order to explore how electric hearing constrains STM sensitivity for CI users differently from acoustic hearing, normal-hearing (NH) and hearing-impaired (HI) listeners were also tested on the same tasks. STM detection performance was best in NH subjects, followed by HI subjects. On average, CI subjects showed poorest performance, but some CI subjects showed high levels of STM detection performance that was comparable to acoustic hearing. Significant correlations were found between STM detection performance and speech identification performance in quiet and in noise. In order to understand the relative contribution of spectral and temporal modulation cues to speech perception abilities for CI users, spectral and temporal modulation detection was performed separately and related to STM detection and speech perception performance. The results suggest that that slow spectral modulation rather than slow temporal modulation may be important for determining speech perception capabilities for CI users. Lastly, test–retest reliability for STM detection was good with no learning. The present study demonstrates that STM detection may be a useful tool to evaluate the ability of CI sound processing strategies to deliver clinically pertinent acoustic modulation information.
Collapse
Affiliation(s)
- Jong Ho Won
- Division of Ophthalmic and Ear, Nose and Throat Devices, Office of Device Evaluation, Center for Devices and Radiological Health, US Food and Drug Administration, Silver Spring, Maryland, United States of America
| | - Il Joon Moon
- Department of Otorhinolaryngology-Head and Neck Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, 135-710, Republic of Korea
- * E-mail:
| | - Sunhwa Jin
- Department of Otorhinolaryngology-Head and Neck Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, 135-710, Republic of Korea
| | - Heesung Park
- Department of Otorhinolaryngology-Head and Neck Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, 135-710, Republic of Korea
| | - Jihwan Woo
- School of Electrical Engineering, Biomedical Engineering, University of Ulsan, Ulsan 680-749, Republic of Korea
| | - Yang-Sun Cho
- Department of Otorhinolaryngology-Head and Neck Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, 135-710, Republic of Korea
| | - Won-Ho Chung
- Department of Otorhinolaryngology-Head and Neck Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, 135-710, Republic of Korea
| | - Sung Hwa Hong
- Department of Otorhinolaryngology-Head and Neck Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, 135-710, Republic of Korea
| |
Collapse
|
56
|
Abstract
OBJECTIVE To determine if unaided, non-linguistic psychoacoustic measures can be effective in evaluating cochlear implant (CI) candidacy. STUDY DESIGN Prospective split-cohort study including predictor development subgroup and independent predictor validation subgroup. SETTING Tertiary referral center. SUBJECTS Fifteen subjects (28 ears) with hearing loss were recruited from patients visiting the University of Washington Medical Center for CI evaluation. METHODS Spectral-ripple discrimination (using a 13-dB modulation depth) and temporal modulation detection using 10- and 100-Hz modulation frequencies were assessed with stimuli presented through insert earphones. Correlations between performance for psychoacoustic tasks and speech perception tasks were assessed. Receiver operating characteristic curve analysis was performed to estimate the optimal psychoacoustic score for CI candidacy evaluation in the development subgroup and then tested in an independent sample. RESULTS Strong correlations were observed between spectral-ripple thresholds and both aided sentence recognition and unaided word recognition. Weaker relationships were found between temporal modulation detection and speech tests. Receiver operating characteristic curve analysis demonstrated that the unaided spectral-ripple discrimination shows a good sensitivity, specificity, positive predictive value, and negative predictive value compared to the current gold standard, aided sentence recognition. CONCLUSION Results demonstrated that the unaided spectral-ripple discrimination test could be a promising tool for evaluating CI candidacy.
Collapse
|
57
|
Davies-Venn E, Nelson P, Souza P. Comparing auditory filter bandwidths, spectral ripple modulation detection, spectral ripple discrimination, and speech recognition: Normal and impaired hearing. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2015; 138:492-503. [PMID: 26233047 PMCID: PMC4514721 DOI: 10.1121/1.4922700] [Citation(s) in RCA: 45] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
Some listeners with hearing loss show poor speech recognition scores in spite of using amplification that optimizes audibility. Beyond audibility, studies have suggested that suprathreshold abilities such as spectral and temporal processing may explain differences in amplified speech recognition scores. A variety of different methods has been used to measure spectral processing. However, the relationship between spectral processing and speech recognition is still inconclusive. This study evaluated the relationship between spectral processing and speech recognition in listeners with normal hearing and with hearing loss. Narrowband spectral resolution was assessed using auditory filter bandwidths estimated from simultaneous notched-noise masking. Broadband spectral processing was measured using the spectral ripple discrimination (SRD) task and the spectral ripple depth detection (SMD) task. Three different measures were used to assess unamplified and amplified speech recognition in quiet and noise. Stepwise multiple linear regression revealed that SMD at 2.0 cycles per octave (cpo) significantly predicted speech scores for amplified and unamplified speech in quiet and noise. Commonality analyses revealed that SMD at 2.0 cpo combined with SRD and equivalent rectangular bandwidth measures to explain most of the variance captured by the regression model. Results suggest that SMD and SRD may be promising clinical tools for diagnostic evaluation and predicting amplification outcomes.
Collapse
Affiliation(s)
- Evelyn Davies-Venn
- Department of Speech-Language-Hearing Sciences, University of Minnesota, 164 Pillsbury Drive Southeast, Minneapolis, Minnesota 55455, USA
| | - Peggy Nelson
- Department of Speech-Language-Hearing Sciences, University of Minnesota, 164 Pillsbury Drive Southeast, Minneapolis, Minnesota 55455, USA
| | - Pamela Souza
- Department of Communication Sciences and Disorders and Knowles Hearing Center, Northwestern University, 2240 Campus Drive, Evanston, Illinois 60208, USA
| |
Collapse
|
58
|
Park MH, Won JH, Horn DL, Rubinstein JT. Acoustic temporal modulation detection in normal-hearing and cochlear implanted listeners: effects of hearing mechanism and development. J Assoc Res Otolaryngol 2015; 16:389-99. [PMID: 25790949 DOI: 10.1007/s10162-014-0499-z] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2014] [Accepted: 11/10/2014] [Indexed: 11/28/2022] Open
Abstract
Temporal modulation detection ability matures over many years after birth and may be particularly sensitive to experience during this period. Profound hearing loss during early childhood might result in greater perceptual deficits than a similar loss beginning in adulthood. We tested this idea by measuring performance in temporal modulation detection in profoundly deaf children and adults fitted with cochlear implants (CIs). At least two independent variables could constrain temporal modulation detection performance in children with CIs: altered encoding of modulation information due to the CI-auditory nerve interface, and atypical development of central processing of sound information provided by CIs. The effect of altered encoding was investigated by testing subjects with one of two different hearing mechanisms (normal hearing vs. CI) and the effect of atypical development was studied by testing two different age groups. All subjects were tested for their ability to detect acoustic temporal modulations of sound amplitude. A comparison of the slope, or cutoff frequency, of the temporal modulation transfer functions (TMTFs) among the four subject groups revealed that temporal resolution was mainly constrained by hearing mechanism: normal-hearing listeners could detect smaller amplitude modulations at high modulation frequencies than CI users. In contrast, a comparison of the height of the TMTFs revealed a significant interaction between hearing mechanism and age group on overall sensitivity to temporal modulation: sensitivity was significantly poorer in children with CIs, relative to the other three groups. Results suggest that there is an age-specific vulnerability of intensity discrimination or non-sensory factors, which subsequently affects sensitivity to temporal modulation in prelingually deaf children who use CIs.
Collapse
Affiliation(s)
- Min-Hyun Park
- Department of Otorhinolaryngology, Boramae Medical Center, Seoul Metropolitan Government - Seoul National University, Seoul, 156-707, Korea
| | | | | | | |
Collapse
|
59
|
Abstract
OBJECTIVES Nonspeech psychophysical tests of spectral resolution, such as the spectral-ripple discrimination task, have been shown to correlate with speech-recognition performance in cochlear implant (CI) users. However, these tests are best suited for use in the research laboratory setting and are impractical for clinical use. A test of spectral resolution that is quicker and could more easily be implemented in the clinical setting has been developed. The objectives of this study were (1) To determine whether this new clinical ripple test would yield individual results equivalent to the longer, adaptive version of the ripple-discrimination test; (2) To evaluate test-retest reliability for the clinical ripple measure; and (3) To examine the relationship between clinical ripple performance and monosyllabic word recognition in quiet for a group of CI listeners. DESIGN Twenty-eight CI recipients participated in the study. Each subject was tested on both the adaptive and the clinical versions of spectral ripple discrimination, as well as consonant-nucleus-consonant word recognition in quiet. The adaptive version of spectral ripple used a two-up, one-down procedure for determining spectral ripple discrimination threshold. The clinical ripple test used a method of constant stimuli, with trials for each of 12 fixed ripple densities occurring six times in random order. Results from the clinical ripple test (proportion correct) were then compared with ripple-discrimination thresholds (in ripples per octave) from the adaptive test. RESULTS The clinical ripple test showed strong concurrent validity, evidenced by a good correlation between clinical ripple and adaptive ripple results (r = 0.79), as well as a correlation with word recognition (r = 0.7). Excellent test-retest reliability was also demonstrated with a high test-retest correlation (r = 0.9). CONCLUSIONS The clinical ripple test is a reliable nonlinguistic measure of spectral resolution, optimized for use with CI users in a clinical setting. The test might be useful as a diagnostic tool or as a possible surrogate outcome measure for evaluating treatment effects in hearing.
Collapse
|
60
|
Oxenham AJ, Kreft HA. Speech perception in tones and noise via cochlear implants reveals influence of spectral resolution on temporal processing. Trends Hear 2014; 18:18/0/2331216514553783. [PMID: 25315376 PMCID: PMC4227666 DOI: 10.1177/2331216514553783] [Citation(s) in RCA: 66] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Under normal conditions, human speech is remarkably robust to degradation by noise and other distortions. However, people with hearing loss, including those with cochlear implants, often experience great difficulty in understanding speech in noisy environments. Recent work with normal-hearing listeners has shown that the amplitude fluctuations inherent in noise contribute strongly to the masking of speech. In contrast, this study shows that speech perception via a cochlear implant is unaffected by the inherent temporal fluctuations of noise. This qualitative difference between acoustic and electric auditory perception does not seem to be due to differences in underlying temporal acuity but can instead be explained by the poorer spectral resolution of cochlear implants, relative to the normally functioning ear, which leads to an effective smoothing of the inherent temporal-envelope fluctuations of noise. The outcome suggests an unexpected trade-off between the detrimental effects of poorer spectral resolution and the beneficial effects of a smoother noise temporal envelope. This trade-off provides an explanation for the long-standing puzzle of why strong correlations between speech understanding and spectral resolution have remained elusive. The results also provide a potential explanation for why cochlear-implant users and hearing-impaired listeners exhibit reduced or absent masking release when large and relatively slow temporal fluctuations are introduced in noise maskers. The multitone maskers used here may provide an effective new diagnostic tool for assessing functional hearing loss and reduced spectral resolution.
Collapse
Affiliation(s)
- Andrew J Oxenham
- Department of Psychology, University of Minnesota, Minneapolis, MN, USA Department of Otolaryngology, University of Minnesota, Minneapolis, MN, USA
| | - Heather A Kreft
- Department of Otolaryngology, University of Minnesota, Minneapolis, MN, USA
| |
Collapse
|
61
|
Oxenham AJ, Kreft HA. Speech perception in tones and noise via cochlear implants reveals influence of spectral resolution on temporal processing. Trends Hear 2014; 18:18/0/2331216514553783. [PMID: 25315376 DOI: 10.1177/233121651455378] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/26/2023] Open
Abstract
Under normal conditions, human speech is remarkably robust to degradation by noise and other distortions. However, people with hearing loss, including those with cochlear implants, often experience great difficulty in understanding speech in noisy environments. Recent work with normal-hearing listeners has shown that the amplitude fluctuations inherent in noise contribute strongly to the masking of speech. In contrast, this study shows that speech perception via a cochlear implant is unaffected by the inherent temporal fluctuations of noise. This qualitative difference between acoustic and electric auditory perception does not seem to be due to differences in underlying temporal acuity but can instead be explained by the poorer spectral resolution of cochlear implants, relative to the normally functioning ear, which leads to an effective smoothing of the inherent temporal-envelope fluctuations of noise. The outcome suggests an unexpected trade-off between the detrimental effects of poorer spectral resolution and the beneficial effects of a smoother noise temporal envelope. This trade-off provides an explanation for the long-standing puzzle of why strong correlations between speech understanding and spectral resolution have remained elusive. The results also provide a potential explanation for why cochlear-implant users and hearing-impaired listeners exhibit reduced or absent masking release when large and relatively slow temporal fluctuations are introduced in noise maskers. The multitone maskers used here may provide an effective new diagnostic tool for assessing functional hearing loss and reduced spectral resolution.
Collapse
Affiliation(s)
- Andrew J Oxenham
- Department of Psychology, University of Minnesota, Minneapolis, MN, USA Department of Otolaryngology, University of Minnesota, Minneapolis, MN, USA
| | - Heather A Kreft
- Department of Otolaryngology, University of Minnesota, Minneapolis, MN, USA
| |
Collapse
|
62
|
Gifford RH, Hedley-Williams A, Spahr AJ. Clinical assessment of spectral modulation detection for adult cochlear implant recipients: a non-language based measure of performance outcomes. Int J Audiol 2014; 53:159-64. [PMID: 24456178 PMCID: PMC4067975 DOI: 10.3109/14992027.2013.851800] [Citation(s) in RCA: 47] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
OBJECTIVE Spectral modulation detection (SMD) provides a psychoacoustic estimate of spectral resolution. The SMD threshold for an implanted ear is highly correlated with speech understanding and is thus a non-linguistic, psychoacoustic index of speech understanding. This measure, however, is time and equipment intensive and thus not practical for clinical use. Thus the purpose of the current study was to investigate the efficacy of a quick SMD task with the following three study aims: (1) to investigate the correlation between the long psychoacoustic, and quick SMD tasks, (2) to determine the test/retest variability of the quick SMD task, and (3) to evaluate the relationship between the quick SMD task and speech understanding. DESIGN This study included a within-subjects, repeated-measures design. STUDY SAMPLE Seventy-six adult cochlear implant recipients participated. RESULTS The results were as follows: (1) there was a significant correlation between the long psychoacoustic, and quick SMD tasks, (2) the test-retest variability of the quick SMD task was highly significant and, (3) there was a significant positive correlation between the quick SMD task and monosyllabic word recognition. CONCLUSIONS The results of this study represent the direct clinical translation of a research-proven task of SMD into a quick, clinically feasible format.
Collapse
Affiliation(s)
- René H. Gifford
- Department of Hearing and Speech Sciences Vanderbilt University, Nashville, TN, USA
| | | | - Anthony J. Spahr
- Department of Hearing and Speech Sciences Vanderbilt University, Nashville, TN, USA
- Advanced Bionics, Valencia, CA, USA
| |
Collapse
|