Kaye AD, Hoover JM, Baber SR, Ibrahim IN, Fields AM. The effects of load on systolic mitral annular velocity by tissue Doppler imaging.
Anesth Analg 2004;
99:758-763. [PMID:
15271700 DOI:
10.1213/01.ane.0000131972.99804.28]
[Citation(s) in RCA: 14] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Tissue Doppler Imaging (TDI) provides information on systolic function through its systolic mitral annulus velocity wave (Sm), reflecting the peak velocity of shortening of the myocardial fibers oriented in the longitudinal direction. In this study, we evaluated the effect of load changes on Sm. Forty-two cardiac surgical patients with left ventricular ejection fraction >60% were consecutively evaluated. In 24 patients, load was changed with an IV bolus of phenylephrine (50-100 microg) or nitroglycerine (300-500 microg); in 18 patients, preload was changed with a rapid infusion of 500 mL of a gelatin solution. The sample volume of TDI was placed at the lateral side of the mitral annulus in the mid-esophageal 4-chamber view. Changing loading conditions with phenylephrine or nitroglycerine had no effect on Sm; the increase of preload in 18 patients resulted in a statistically significant increase of Sm (baseline, 8.4 +/- 2.6 cm/s; after increase of preload, 9.6 +/- 2.5 cm/s; P = 0.001). We conclude that Sm is dependent on changes in preload obtained by volume loading and cannot be recommended as an index of ventricular contractile performance in critically ill patients where significant changes in ventricular filling occur.