51
|
Etard C, Aubert B, Mezzarobba M, Bernier MO. Exposure of the French paediatric population to ionising radiation from diagnostic medical procedures in 2010. Pediatr Radiol 2014; 44:1588-94. [PMID: 25030220 DOI: 10.1007/s00247-014-3065-2] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/13/2014] [Revised: 04/17/2014] [Accepted: 05/21/2014] [Indexed: 10/25/2022]
Abstract
BACKGROUND Medical examination is the main source of artificial radiation exposure. Because children present an increased sensitivity to ionising radiation, radiology practices at a national level in paediatrics should be monitored. OBJECTIVE This study describes the ionising radiation exposure from diagnostic medical examinations of the French paediatric population in 2010. MATERIALS AND METHODS Data on frequency of examinations were provided by the French National Health Insurance through a representative sample including 107,627 children ages 0-15 years. Effective doses for each type of procedure were obtained from the published French literature. Median and mean effective doses were calculated for the studied population. RESULTS About a third of the children were exposed to at least one examination using ionising radiation in 2010. Conventional radiology, dental exams, CT scans and nuclear medicine and interventional radiology represent respectively 55.3%, 42.3%, 2.1% and 0.3% of the procedures. Children 10-15 years old and babies from birth to 1 year are the most exposed populations, with respectively 1,098 and 734 examinations per 1,000 children per year. Before 1 year of age, chest and pelvis radiographs are the most common imaging tests, 54% and 32%, respectively. Only 1% of the studied population is exposed to CT scan, with 62% of these children exposed to a head-and-neck procedure. The annual median and mean effective doses were respectively 0.03 mSv and 0.7 mSv for the exposed children. CONCLUSION This study gives updated reference data on French paediatric exposure to medical ionising radiation that can be used for public health or epidemiological purposes. Paediatric diagnostic use appears much lower than that of the whole French population as estimated in a previous study.
Collapse
Affiliation(s)
- Cécile Etard
- Medical Expertise Unit, Institut de Radioprotection et de Sûreté Nucléaire, Fontenay-aux-Roses, France
| | | | | | | |
Collapse
|
52
|
Journy N, Rehel JL, Ducou Le Pointe H, Lee C, Brisse H, Chateil JF, Caer-Lorho S, Laurier D, Bernier MO. Are the studies on cancer risk from CT scans biased by indication? Elements of answer from a large-scale cohort study in France. Br J Cancer 2014; 112:185-93. [PMID: 25314057 PMCID: PMC4453597 DOI: 10.1038/bjc.2014.526] [Citation(s) in RCA: 146] [Impact Index Per Article: 14.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2014] [Revised: 09/08/2014] [Accepted: 09/09/2014] [Indexed: 11/09/2022] Open
Abstract
BACKGROUND Recent epidemiological results suggested an increase of cancer risk after receiving computed tomography (CT) scans in childhood or adolescence. Their interpretation is questioned due to the lack of information about the reasons for examination. Our objective was to estimate the cancer risk related to childhood CT scans, and examine how cancer-predisposing factors (PFs) affect assessment of the radiation-related risk. METHODS The cohort included 67,274 children who had a first scan before the age of 10 years from 2000 to 2010 in 23 French departments. Cumulative X-rays doses were estimated from radiology protocols. Cancer incidence was retrieved through the national registry of childhood cancers; PF from discharge diagnoses. RESULTS During a mean follow-up of 4 years, 27 cases of tumours of the central nervous system, 25 of leukaemia and 21 of lymphoma were diagnosed; 32% of them among children with PF. Specific patterns of CT exposures were observed according to PFs. Adjustment for PF reduced the excess risk estimates related to cumulative doses from CT scans. No significant excess risk was observed in relation to CT exposures. CONCLUSIONS This study suggests that the indication for examinations, whether suspected cancer or PF management, should be considered to avoid overestimation of the cancer risks associated with CT scans.
Collapse
Affiliation(s)
- N Journy
- Laboratory of Epidemiology, Institute for Radiological Protection and Nuclear Safety, BP 17, 92262 Fontenay-aux-Roses, France
| | - J-L Rehel
- Medical Radiation Protection Expertise Unit, Institute for Radiological Protection and Nuclear Safety, BP 17, 92262 Fontenay-aux-Roses, France
| | - H Ducou Le Pointe
- Department of Paediatric Radiology, Trousseau University Hospital, 26 avenue du Docteur Arnold-Netter, 75012 Paris, France
| | - C Lee
- Division of Cancer Epidemiology and Genetics, National Cancer Institute, National Institute of Health, 9000 Rockville Pike, 20892 Bethesda, MD, USA
| | - H Brisse
- Department of Radiology, Institut Curie, 11-13 rue Pierre et Marie Curie, 75005 Paris, France
| | - J-F Chateil
- Department of Paediatric Radiology, Pellegrin University Hospital, Place Amélie Raba-Léon, 33000 Bordeaux, France
| | - S Caer-Lorho
- Laboratory of Epidemiology, Institute for Radiological Protection and Nuclear Safety, BP 17, 92262 Fontenay-aux-Roses, France
| | - D Laurier
- Laboratory of Epidemiology, Institute for Radiological Protection and Nuclear Safety, BP 17, 92262 Fontenay-aux-Roses, France
| | - M-O Bernier
- Laboratory of Epidemiology, Institute for Radiological Protection and Nuclear Safety, BP 17, 92262 Fontenay-aux-Roses, France
| |
Collapse
|
53
|
Buratovic S, Stenerlöw B, Fredriksson A, Sundell-Bergman S, Viberg H, Eriksson P. Neonatal exposure to a moderate dose of ionizing radiation causes behavioural defects and altered levels of tau protein in mice. Neurotoxicology 2014; 45:48-55. [PMID: 25265567 DOI: 10.1016/j.neuro.2014.09.002] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2014] [Revised: 09/15/2014] [Accepted: 09/18/2014] [Indexed: 10/24/2022]
Abstract
Medical use of ionizing radiation (IR) has great benefits for treatment and diagnostic imaging, but procedures as computerized tomography (CT) may deliver a significant radiation dose to the patient. Recently, awareness has been raised about possible non-cancer consequences from low dose exposure to IR during critical phases of perinatal and/or neonatal brain development. In the present study neonatal NMRI mice were whole body irradiated with a single dose of gamma radiation (0; 350 and 500 mGy) on postnatal day 10 (PND 10). At 2 and 4 months of age, mice of both sexes were observed for spontaneous behaviour in a novel home environment. The neuroproteins CaMKII, GAP-43, synaptophysin and total tau in male mouse cerebral cortex and hippocampus were analysed 24h post-irradiation and in adults at 6 months of age exposed to 0 or 500 mGy on PND 10. A significantly dose-response related deranged spontaneous behaviour in 2- and 4-month-old mice was observed, where both males and females displayed a modified habituation, indicating reduced cognitive function. The dose of 350 mGy seems to be a tentative threshold. Six-month-old male mice showed a significantly increased level of total tau in cerebral cortex after irradiation to 500 mGy compared to controls. This demonstrates that a single moderate dose of IR, given during a defined critical period of brain development, is sufficient to cause persistently reduced cognitive function. Moreover, an elevation of tau protein was observed in male mice displaying reduced cognitive function.
Collapse
Affiliation(s)
- Sonja Buratovic
- Department of Environmental Toxicology, Uppsala University, Norbyvägen 18A, SE-75236 Uppsala, Sweden.
| | - Bo Stenerlöw
- Department of Radiology, Oncology and Radiation Science, Uppsala University, Uppsala, Sweden
| | - Anders Fredriksson
- Department of Environmental Toxicology, Uppsala University, Norbyvägen 18A, SE-75236 Uppsala, Sweden
| | - Synnöve Sundell-Bergman
- Department of Soil and Environment, Swedish University of Agricultural Sciences, Uppsala, Sweden
| | - Henrik Viberg
- Department of Environmental Toxicology, Uppsala University, Norbyvägen 18A, SE-75236 Uppsala, Sweden
| | - Per Eriksson
- Department of Environmental Toxicology, Uppsala University, Norbyvägen 18A, SE-75236 Uppsala, Sweden
| |
Collapse
|
54
|
Barnaoui S, Rehel JL, Baysson H, Boudjemline Y, Girodon B, Bernier MO, Bonnet D, Aubert B. Local reference levels and organ doses from pediatric cardiac interventional procedures. Pediatr Cardiol 2014; 35:1037-45. [PMID: 24651982 DOI: 10.1007/s00246-014-0895-5] [Citation(s) in RCA: 45] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/15/2013] [Accepted: 02/28/2014] [Indexed: 10/25/2022]
Abstract
Interventional cardiology (IC) procedures can be responsible for relatively high radiation doses compared to conventional radiology especially for young patients. The aim of this study was to assess current exposure levels in a French reference centre of pediatric IC. Dosimetric data including dose area product (DAP), fluoroscopy time (FT) and number of cine frame (NF) were analysed taking into account patient weight. Doses to the lungs, esophagus, breast and thyroid were evaluated using anthropomorphic phantoms and thermoluminescent dosimeters. Finally, effective doses (E) were calculated using DAP and conversion factors calculated with PCXMC 2.0 software. 801 IC procedures performed between 2010 and 2011 were analysed. Large variations were observed for DAP, FT and NF values for a given procedure and a given weight group. The assessment of organ doses showed high levels of dose to the lungs and esophagus especially in new-born babies. For diagnostic procedures, E varied from 0.3 to 23 mSv with a mean value of 4.8 mSv and for therapeutic procedures, values ranged from 0.1 to 48.4 mSv with a mean value of 7.3 mSv. The highest values were recorded for angioplasty procedures (mean 13 mSv, range 0.6-48.4 mSv). The increasing use of IC in pediatric population stresses the need of setting up reference levels and keeping doses to children as low as possible.
Collapse
Affiliation(s)
- S Barnaoui
- Medical Radiation Protection Expertise Unit, Institute of Radioprotection and Nuclear Safety, Fontenay-aux-Roses, France
| | | | | | | | | | | | | | | |
Collapse
|
55
|
Welkoborsky HJ, Graß S, Deichmüller C, Bertram O, Hinni ML. Orbital complications in children: differential diagnosis of a challenging disease. Eur Arch Otorhinolaryngol 2014; 272:1157-63. [PMID: 25056021 DOI: 10.1007/s00405-014-3195-z] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2014] [Accepted: 07/02/2014] [Indexed: 10/25/2022]
Abstract
Orbital swelling in children presents diagnostic and therapeutic challenges. Most are associated with acute sinusitis with complicating factors possibly including: amaurosis, meningitis, intracranial abscess or even cavernous sinus thrombosis. However not all acute orbital swelling is associated with acute sinusitis. A careful evaluation is critical prior to initiating therapy. Clinical records of 49 children (27 girls, 22 boys, with an average age of 11.8 years) were retrospectively reviewed. Historical data evaluated included all available information from parents and previous treating physicians. All patients underwent intensive pediatric, ophthalmologic, and otorhinolaryngologic examinations. Computed tomography (CT scans) were additionally performed in 40 % of children. The results of any examinations were also evaluated. Eighteen of the 49 patients had an orbital complication due to acute sinusitis. All 18 had elevated body temperature, C-Reactive Protein (CRP) values and white blood cell counts. Endoscopy of the nose revealed pus in the middle meatus in each case. According to Chandlers' classification, ten children presented with a preseptal, and eight children had a postseptal orbital cellulitis. All patients were admitted to the hospital and treated with intravenous antibiotics. CT scans further demonstrated signs of subperiostal abscess in four children. Functional endoscopic sinus surgery (FESS) was required in six children, including all patients with subperiostal abscess. Twenty children experienced orbital swelling unrelated to acute sinusitis, i.e. atheroma, inflammed insect stings, dental related abscess, conjunctivitis, and Herpes simplex associated superinfection. In three children, acute orbital swelling was caused by an orbital tumor. Orbital complications of an acute sinusitis occur often in the pediatric patient group, and most of these patients can be treated conservative with intravenous antibiotics. Indications for FESS include failure to improve or worsening of clinical symptoms during 24 h of therapy, signs for subperiostal abscess in CT scan, and/or vision loss. Patients with infectous orbital complications had fever, elevated CRP and white blood cell counts. This symptom complex is key in making the correct diagnosis. Interestingly, 61 % of patients in this study demonstrated non-sinusitis related diseases leading to acute orbital swelling, which also required prompt recognition and appropriate therapy.
Collapse
Affiliation(s)
- Hans-J Welkoborsky
- Department of Otorhinolaryngology, Head and Neck Surgery, Nordstadt Clinic, Academic Hospital and Childrens' Hospital "Auf Der Bult", Academic Hospital, Haltenhoffstrasse 41, 30167, Hannover, Germany,
| | | | | | | | | |
Collapse
|
56
|
Kuo W, Ciet P, Tiddens HAWM, Zhang W, Guillerman RP, van Straten M. Monitoring Cystic Fibrosis Lung Disease by Computed Tomography. Radiation Risk in Perspective. Am J Respir Crit Care Med 2014; 189:1328-36. [DOI: 10.1164/rccm.201311-2099ci] [Citation(s) in RCA: 100] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023] Open
|
57
|
White IK, Shaikh KA, Moore RJ, Bullis CL, Sami MT, Gianaris TJ, Fulkerson DH. Risk of radiation-induced malignancies from CT scanning in children who underwent shunt treatment before 6 years of age: a retrospective cohort study with a minimum 10-year follow-up. J Neurosurg Pediatr 2014; 13:514-9. [PMID: 24628509 DOI: 10.3171/2014.2.peds12508] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
OBJECT A number of mathematical models predict the risk of future cancer from the ionizing radiation exposure of CT scanning. The predictions are alarming. Some models predict 29,000 future cancers and 14,500 deaths in the US will be directly caused by 1 year's worth of CT scanning. However, there are very few clinical data to justify or refute these claims. Young children are theoretically highly susceptible to the damaging effects of radiation. In this study, the authors examined children who underwent CSF shunt placement before 6 years of age. The authors chose to study shunt-treated patients with the assumption that these patients would undergo future imaging, facilitating surveillance. They chose a study period of 1991-2001 to allow more than 10 years of follow-up data. METHODS The authors studied 104 consecutive children who underwent CSF shunt placement prior to 6 years of age and who had at least 10 years of follow-up data. Sixty-two of these patients underwent shunt placement prior to 1 year of age. The age at the initial scanning session, the number of future CT scanning sessions, diagnosis, and results of any future studies were recorded. The age-specific radiation dose was calculated for children younger than 1 year. Children younger than 1 year at the time of shunt placement were evaluated separately, based on the assumption that they represented the highest risk cohort. The authors examined all data for any evidence of future leukemia or head/neck tumor (benign or malignant). RESULTS These children underwent a total of 1584 CT scanning sessions over a follow-up period of 1622 person-years. A total of 517 scanning sessions were performed prior to 6 years of age, including 260 in the 1st year of life. Children who underwent shunt placement before 1 year of age underwent an average of 16.3 ± 13.5 CT sessions (range 1-41). Children undergoing placement between 1 and 6 years of age received an average of 14.1 ± 12.5 CT studies (range 5-52). There were no subsequent tumors (benign or malignant) or leukemia detected. CONCLUSIONS Previously published models predict a significant number of future cancers directly caused by CT scanning. However, there are very few published clinical data. In the authors' study, zero future radiation-induced malignancies were detected after routine CT scanning in a high-risk group. While the authors do not consider their single-institution study adequate to define the actual risk, their data suggest that the overall risk is low. The authors hope this study encourages future collaborative efforts to define the actual risk to patients.
Collapse
Affiliation(s)
- Ian K White
- Department of Neurosurgery, Indiana University School of Medicine; and
| | | | | | | | | | | | | |
Collapse
|
58
|
Journy N, Ancelet S, Rehel JL, Mezzarobba M, Aubert B, Laurier D, Bernier MO. Predicted cancer risks induced by computed tomography examinations during childhood, by a quantitative risk assessment approach. RADIATION AND ENVIRONMENTAL BIOPHYSICS 2014; 53:39-54. [PMID: 24105448 DOI: 10.1007/s00411-013-0491-8] [Citation(s) in RCA: 49] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/23/2013] [Accepted: 09/08/2013] [Indexed: 06/02/2023]
Abstract
The potential adverse effects associated with exposure to ionizing radiation from computed tomography (CT) in pediatrics must be characterized in relation to their expected clinical benefits. Additional epidemiological data are, however, still awaited for providing a lifelong overview of potential cancer risks. This paper gives predictions of potential lifetime risks of cancer incidence that would be induced by CT examinations during childhood in French routine practices in pediatrics. Organ doses were estimated from standard radiological protocols in 15 hospitals. Excess risks of leukemia, brain/central nervous system, breast and thyroid cancers were predicted from dose-response models estimated in the Japanese atomic bomb survivors' dataset and studies of medical exposures. Uncertainty in predictions was quantified using Monte Carlo simulations. This approach predicts that 100,000 skull/brain scans in 5-year-old children would result in eight (90 % uncertainty interval (UI) 1-55) brain/CNS cancers and four (90 % UI 1-14) cases of leukemia and that 100,000 chest scans would lead to 31 (90 % UI 9-101) thyroid cancers, 55 (90 % UI 20-158) breast cancers, and one (90 % UI <0.1-4) leukemia case (all in excess of risks without exposure). Compared to background risks, radiation-induced risks would be low for individuals throughout life, but relative risks would be highest in the first decades of life. Heterogeneity in the radiological protocols across the hospitals implies that 5-10 % of CT examinations would be related to risks 1.4-3.6 times higher than those for the median doses. Overall excess relative risks in exposed populations would be 1-10 % depending on the site of cancer and the duration of follow-up. The results emphasize the potential risks of cancer specifically from standard CT examinations in pediatrics and underline the necessity of optimization of radiological protocols.
Collapse
Affiliation(s)
- Neige Journy
- Laboratory of Epidemiology, Institut de Radioprotection et de Sûreté Nucléaire, Fontenay-aux-Roses, France
| | | | | | | | | | | | | |
Collapse
|
59
|
[Chest computed tomography in children: indications, efficiency and effective dose]. Arch Pediatr 2014; 21:279-86. [PMID: 24485863 DOI: 10.1016/j.arcped.2013.12.021] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2013] [Revised: 11/21/2013] [Accepted: 12/27/2013] [Indexed: 12/28/2022]
Abstract
INTRODUCTION New multidetector row computed tomography (CT) has made the imaging of younger children more feasible and extending CT indications to a wide range of pediatric respiratory diseases in the last few years. However, CT is a source of radiation exposure. The aim of this study was to evaluate the main indications and the contribution of chest CT in pediatric pulmonology as well as induced radiation. METHODS This was an observational, prospective study. Children whose chest CTs were analyzed during multidisciplinary meetings (radiologist, pulmonary pediatrician) were included from November 2009 to April 2010. We collected demographic data, CT results, contribution of CT to diagnosis and management, and radiation doses (dose-length product [DLP] and effective dose). Radiation doses were compared according to the CT scans (Lille University Hospital with 128-slice dual-source CT or Lille University Hospital single-source 64-slice CT, or CT performed outside the university hospital). RESULTS One hundred thirty-five patients were included. The mean age was 6.4 years old. The main indications were analysis of bronchial disease (44%), infectious disease (16%), interstitial disease (14%), or a malformation (9%). The aim of CT was diagnosis (61%) or follow-up of previous lung diseases (39%). Diagnosis chest-CT directly contributed to diagnosis in 48% of cases and to treatment in 24%. Follow-up CT contributed to diagnosis in 38% and treatment in 19% of cases. DLP and effective doses were significantly lower for CT performed in the university hospital, especially with the 128-slice CT compared to the others (P<0.001). The effective doses were: 128-slice CT, 0.61 mSv ± 0.32; 64-slice CT, 1.24 mSv ± 0.97; outside university hospital, 2.56 mSv ± 1.98. CONCLUSION This study confirms the role played by chest CT in children, which contributes to diagnosis and management of lung diseases. The main concern of CT application, especially in children, is the radiation burden. Children are more susceptible to the effects of radiation than adults and have a longer life expectancy to develop complications. Both radiologists and pediatricians should be aware of a potential risk and have to conjugate their efforts in reducing this risk. The wide range of radiation doses in this study for the same CT procedures underlines the extensive efforts still needed to limit radiation exposure in children.
Collapse
|
60
|
Cooke DL, Stout CE, Kim WT, Hetts SW, Higashida RT, Halbach VV, Dowd CF, Gould RG. Radiation dose reduction in intra-arterial chemotherapy infusion for intraocular retinoblastoma. J Neurointerv Surg 2014; 6:785-9. [PMID: 24385553 DOI: 10.1136/neurintsurg-2013-010905] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
BACKGROUND AND PURPOSE Retinoblastoma (RB) is a rare malignancy affecting the pediatric population. Intravenous chemotherapy is the longstanding delivery method, although intra-arterial (IA) chemotherapy is gaining popularity given the reduced side effects compared with systemic chemotherapy administration. Given the sensitivity of the target organ, patient age, and secondary tumor susceptibility, a premium has been placed on minimizing procedural related radiation exposure. MATERIALS AND METHODS To reduce patient x-ray dose during the IA infusion procedure, customized surgical methods and fluoroscopic techniques were employed. The routine fluoroscopic settings were changed from the standard 7.5 pulses/s and dose level to the detector of 36 nGy/pulse, to a pulse rate of 4 pulses/s and detector dose to 23 nGy/pulse. The angiographic dose indicators (reference point air kerma (Ka) and fluoroscopy time) for a cohort of 10 consecutive patients (12 eyes, 30 infusions) were analyzed. An additional four cases (five eyes, five infusions) were analyzed using dosimeters placed at anatomic locations to reflect scalp, eye, and thyroid dose. RESULTS The mean Ka per treated eye was 20.1±11.9 mGy with a mean fluoroscopic time of 8.5±4.6 min. Dosimetric measurements demonstrated minimal dose to the lens (0.18±0.10 mGy). Measured entrance skin doses varied from 0.7 to 7.0 mGy and were 73.4±19.7% less than the indicated Ka value. CONCLUSIONS Ophthalmic arterial melphalan infusion is a safe and effective means to treat RB. Modification to contemporary fluoroscopic systems combined with parsimonious fluoroscopy can minimize radiation exposure.
Collapse
Affiliation(s)
- Daniel L Cooke
- Department of Radiology and Biomedical Imaging, University California San Francisco, San Francisco, California, USA
| | - Charles E Stout
- Department of Radiology and Biomedical Imaging, University California San Francisco, San Francisco, California, USA
| | - Warren T Kim
- Department of Radiology and Biomedical Imaging, University California San Francisco, San Francisco, California, USA
| | - Steven W Hetts
- Department of Radiology and Biomedical Imaging, University California San Francisco, San Francisco, California, USA
| | - Randall T Higashida
- Department of Radiology and Biomedical Imaging, University California San Francisco, San Francisco, California, USA
| | - Van V Halbach
- Department of Radiology and Biomedical Imaging, University California San Francisco, San Francisco, California, USA
| | - Christopher F Dowd
- Department of Radiology and Biomedical Imaging, University California San Francisco, San Francisco, California, USA
| | - Robert G Gould
- Department of Radiology and Biomedical Imaging, University California San Francisco, San Francisco, California, USA
| |
Collapse
|
61
|
Bauman G, Puderbach M, Heimann T, Kopp-Schneider A, Fritzsching E, Mall MA, Eichinger M. Validation of Fourier decomposition MRI with dynamic contrast-enhanced MRI using visual and automated scoring of pulmonary perfusion in young cystic fibrosis patients. Eur J Radiol 2013; 82:2371-7. [DOI: 10.1016/j.ejrad.2013.08.018] [Citation(s) in RCA: 82] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2013] [Revised: 07/30/2013] [Accepted: 08/06/2013] [Indexed: 11/30/2022]
|
62
|
Abstract
Many assumptions are made when imaging children. In particular a judgement is made regarding how safe or unsafe each imaging modality is, using relatively arbitrary definitions and distinctions, due to the lack of robust scientific data. Here, the latest evidence is reviewed, particularly regarding the medical exposure to ionizing radiation (X-rays and CT) and MRI in childhood. The best evidence currently available suggests a small but convincing risk of cumulative low-dose ionizing radiation in children. Given our predictions for the children imaged today, it seems reasonable to pursue non-ionizing-based techniques wherever possible, although there is emerging evidence that MRI and ultrasound may have hitherto unknown effects. As our knowledge base expands, we must continually review our practice in light of the latest scientific data.
Collapse
Affiliation(s)
| | - Alvhild Alette Bj⊘rkum
- Departments of Biomedical Laboratory
Sciences and Chemical Engineering, Faculty of Engineering, Bergen University
College, Bergen, Norway
| |
Collapse
|
63
|
Palorini F, Origgi D, Granata C, Matranga D, Salerno S. Adult exposures from MDCT including multiphase studies: first Italian nationwide survey. Eur Radiol 2013; 24:469-83. [DOI: 10.1007/s00330-013-3031-7] [Citation(s) in RCA: 55] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2013] [Revised: 08/12/2013] [Accepted: 09/09/2013] [Indexed: 11/28/2022]
|
64
|
Bhangu A. Multicentre observational study of performance variation in provision and outcome of emergency appendicectomy. Br J Surg 2013; 100:1240-52. [PMID: 23842836 DOI: 10.1002/bjs.9201] [Citation(s) in RCA: 145] [Impact Index Per Article: 13.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/13/2013] [Indexed: 12/16/2022]
Abstract
BACKGROUND Identification of variation in practice is a key step towards standardization of service and determination of reliable quality markers. This study aimed to investigate variation in provision and outcome of emergency appendicectomy. METHODS A multicentre, trainee-led, protocol-driven, prospective observational cohort study was performed during May and June 2012. The main outcome of interest was the normal histopathology rate; secondary outcomes were laparoscopy and 30-day adverse event rates. Analysis included funnel plots and binary logistic regression models to identify patient- and hospital-related predictors of outcome. RESULTS A total of 3326 patients from 95 centres were included. An initial laparoscopic approach was performed in 66.3 per cent of patients (range in centres performing more than 25 appendicectomies over the study period: 8.7-100 per cent). A histologically normal appendix was removed in 20.6 per cent of patients (range in centres performing more than 25 procedures: 3.3-36.8 per cent). Funnel plot analysis revealed that 22 centres fell below three standard deviations of the mean for laparoscopy rates. Higher centre volume, consultant presence in theatre and daytime surgery were independently associated with an increased use of laparoscopy, which in turn was associated with a reduction in 30-day morbidity (adjusted for disease severity). Daytime surgery further reduced normal appendicectomy rates. Increasing volume came at the cost of higher negative rates, and low negative rates came at the cost of higher perforation rates. CONCLUSION This study reveals the extremely wide variation in practice patterns and outcomes among hospitals. Organizational factors leading to this variation have been identified and should be addressed to improve performance.
Collapse
Affiliation(s)
| | - A Bhangu
- Academic Department of Surgery, Room 29, 4th Floor, Queen Elizabeth Hospital, Edgbaston, Birmingham B15 2TH, UK
| |
Collapse
|
65
|
Yentrapalli R, Azimzadeh O, Sriharshan A, Malinowsky K, Merl J, Wojcik A, Harms-Ringdahl M, Atkinson MJ, Becker KF, Haghdoost S, Tapio S. The PI3K/Akt/mTOR pathway is implicated in the premature senescence of primary human endothelial cells exposed to chronic radiation. PLoS One 2013; 8:e70024. [PMID: 23936371 PMCID: PMC3731291 DOI: 10.1371/journal.pone.0070024] [Citation(s) in RCA: 72] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2013] [Accepted: 06/20/2013] [Indexed: 11/18/2022] Open
Abstract
The etiology of radiation-induced cardiovascular disease (CVD) after chronic exposure to low doses of ionizing radiation is only marginally understood. We have previously shown that a chronic low-dose rate exposure (4.1 mGy/h) causes human umbilical vein endothelial cells (HUVECs) to prematurely senesce. We now show that a dose rate of 2.4 mGy/h is also able to trigger premature senescence in HUVECs, primarily indicated by a loss of growth potential and the appearance of the senescence-associated markers ß-galactosidase (SA-ß-gal) and p21. In contrast, a lower dose rate of 1.4 mGy/h was not sufficient to inhibit cellular growth or increase SA-ß-gal-staining despite an increased expression of p21. We used reverse phase protein arrays and triplex Isotope Coded Protein Labeling with LC-ESI-MS/MS to study the proteomic changes associated with chronic radiation-induced senescence. Both technologies identified inactivation of the PI3K/Akt/mTOR pathway accompanying premature senescence. In addition, expression of proteins involved in cytoskeletal structure and EIF2 signaling was reduced. Age-related diseases such as CVD have been previously associated with increased endothelial cell senescence. We postulate that a similar endothelial aging may contribute to the increased rate of CVD seen in populations chronically exposed to low-dose-rate radiation.
Collapse
Affiliation(s)
- Ramesh Yentrapalli
- Helmholtz Zentrum München, German Research Center for Environmental Health, Institute of Radiation Biology, Neuherberg, Germany
- Centre for Radiation Protection Research, Department of Molecular Biosciences, The Wenner-Gren Institute, Stockholm University, Stockholm, Sweden
| | - Omid Azimzadeh
- Helmholtz Zentrum München, German Research Center for Environmental Health, Institute of Radiation Biology, Neuherberg, Germany
| | - Arundhathi Sriharshan
- Helmholtz Zentrum München, German Research Center for Environmental Health, Institute of Radiation Biology, Neuherberg, Germany
| | | | - Juliane Merl
- Research Unit Protein Science, Helmholtz Zentrum Muenchen, German Research Center for Environmental Health (GmbH), Neuherberg, Germany
| | - Andrzej Wojcik
- Centre for Radiation Protection Research, Department of Molecular Biosciences, The Wenner-Gren Institute, Stockholm University, Stockholm, Sweden
| | - Mats Harms-Ringdahl
- Centre for Radiation Protection Research, Department of Molecular Biosciences, The Wenner-Gren Institute, Stockholm University, Stockholm, Sweden
| | - Michael J. Atkinson
- Helmholtz Zentrum München, German Research Center for Environmental Health, Institute of Radiation Biology, Neuherberg, Germany
- Department of Radiation Oncology, Klinikum Rechts der Isar, Technische Universität München, Munich, Germany
| | | | - Siamak Haghdoost
- Centre for Radiation Protection Research, Department of Molecular Biosciences, The Wenner-Gren Institute, Stockholm University, Stockholm, Sweden
| | - Soile Tapio
- Helmholtz Zentrum München, German Research Center for Environmental Health, Institute of Radiation Biology, Neuherberg, Germany
- * E-mail:
| |
Collapse
|
66
|
Mandiwanza T, Saidlear C, Caird J, Crimmins D. The open fontanelle: a window to less radiation. Childs Nerv Syst 2013; 29:1177-81. [PMID: 23516042 DOI: 10.1007/s00381-013-2073-0] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/27/2013] [Accepted: 02/27/2013] [Indexed: 01/21/2023]
Abstract
INTRODUCTION Over the years, there has been increasing awareness of the radiation doses from medical investigation and treatment modalities and the long-term effect of this radiation. In no other patient population is this more of an issue than in the paediatric population who are more radiosensitive and have a longer life span in which to express any negative effects of radiation. In children under the age of one, the anterior fontanelle is an acoustic window to intracranial structures allowing for the use of cranial ultrasound (CRUSS) instead of CT. AIM To determine the pattern of CT and Cranial ultrasound used in patients aged one or younger with shunt treated hydrocephalus. METHODS A retrospective review of patients who had a shunt inserted before the age of one and their imaging. Effective radiation doses were calculated for those who had CT scans. RESULTS One hundred thirty-five patients were included with 227 CTs and 124 CRUSS conducted. In the follow-up period after shunt insertion, 92 patients had CTs while 14 were followed with CRUSS and 51 patients required a shunt revision before the age of one. The average effective radiation dose per scan was 2.76 mSv. CONCLUSION Children with an open fontanelle and shunt can be followed reliably with CRUSS in order to reduce their exposure to radiation.
Collapse
Affiliation(s)
- Tafadzwa Mandiwanza
- Department of Paediatric Neurosurgery, Children's University Hospital, Temple Street, Dublin 1, Republic of Ireland.
| | - Colm Saidlear
- Department of Radiology, Children's University Hospital, Temple Street, Dublin 1, Republic of Ireland
| | - John Caird
- Department of Paediatric Neurosurgery, Children's University Hospital, Temple Street, Dublin 1, Republic of Ireland
| | - Darach Crimmins
- Department of Paediatric Neurosurgery, Children's University Hospital, Temple Street, Dublin 1, Republic of Ireland
| |
Collapse
|
67
|
Baysson H, Réhel JL, Boudjemline Y, Petit J, Girodon B, Aubert B, Laurier D, Bonnet D, Bernier MO. Risk of cancer associated with cardiac catheterization procedures during childhood: a cohort study in France. BMC Public Health 2013; 13:266. [PMID: 23521893 PMCID: PMC3621730 DOI: 10.1186/1471-2458-13-266] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2013] [Accepted: 03/08/2013] [Indexed: 12/03/2022] Open
Abstract
BACKGROUND Radiation can be used effectively for diagnosis and medical treatment, but it can also cause cancers later on. Children with congenital heart disease frequently undergo cardiac catheterization procedures for diagnostic or treatment purposes. Despite the clear clinical benefit to the patient, the complexity of these procedures may result in high cumulative radiation exposure. Given children's greater sensitivity to radiation and the longer life span during which radiation health effects can develop, an epidemiological cohort study is being launched in France to evaluate the risks of leukaemia and solid cancers in this specific population. METHODS/DESIGN The study population will include all children who have undergone at least one cardiac catheterization procedure since 2000 and were under 10 years old and permanent residents of France at the time of the procedure. Electronically stored patient records from the departments of paediatric cardiology of the French national network for complex congenital heart diseases (M3C) are being searched to identify the children to be included. The minimum dataset will comprise: identification of the subject (file number in the centre or department, full name, sex, date and place of birth), and characteristics of the intervention (date, underlying disease, type of procedure, technical details, such as fluoroscopy time and dose area product, (DAP), which are needed to reconstruct the doses received by each child). The cohort will be followed up through linkage with the two French paediatric cancer registries, which have recorded all cases of childhood leukaemia and solid cancers in France since 1990 and 2000, respectively. Radiation exposure will be estimated retrospectively for each child. 4500 children with catherizations between 2000 and 2011 have been already included in the cohort, and recruitment is ongoing at the national level. The study is expected to finally include a total of 8000 children. DISCUSSION This French cohort study is specifically designed to provide further knowledge about the potential cancer risks associated with paediatric cardiac catheterization procedures. It will also provide new information on typical dose levels associated with these procedures in France. Finally, it should help improve awareness of the importance of radiation protection in these procedures.
Collapse
Affiliation(s)
- Helene Baysson
- Institut de Radioprotection et de Sûreté Nucléaire, PRP-HOM, SRBE, BP 17, Fontenay aux Roses, France
| | - Jean Luc Réhel
- Institut de Radioprotection et de Sûreté Nucléaire, PRP-HOM, SRBE, BP 17, Fontenay aux Roses, France
| | - Younes Boudjemline
- Centre de Référence Malformations Cardiaques Congénitales Complexes, M3C, Hôpital Necker-Enfants malades, AP-HP, Université Paris Descartes, Sorbonne Paris Cité, Paris, France
| | - Jerôme Petit
- Centre de Référence Malformations Cardiaques Congénitales Complexes, M3C, Centre Chirurgical Marie Lannelongue, Le Plessis Robinson, France
| | - Brigitte Girodon
- Centre de Référence Malformations Cardiaques Congénitales Complexes, M3C, Hôpital Necker-Enfants malades, AP-HP, Université Paris Descartes, Sorbonne Paris Cité, Paris, France
| | - Bernard Aubert
- Institut de Radioprotection et de Sûreté Nucléaire, PRP-HOM, SRBE, BP 17, Fontenay aux Roses, France
| | - Dominique Laurier
- Institut de Radioprotection et de Sûreté Nucléaire, PRP-HOM, SRBE, BP 17, Fontenay aux Roses, France
| | - Damien Bonnet
- Centre de Référence Malformations Cardiaques Congénitales Complexes, M3C, Hôpital Necker-Enfants malades, AP-HP, Université Paris Descartes, Sorbonne Paris Cité, Paris, France
| | - Marie-Odile Bernier
- Institut de Radioprotection et de Sûreté Nucléaire, PRP-HOM, SRBE, BP 17, Fontenay aux Roses, France
| |
Collapse
|
68
|
Kempf SJ, Azimzadeh O, Atkinson MJ, Tapio S. Long-term effects of ionising radiation on the brain: cause for concern? RADIATION AND ENVIRONMENTAL BIOPHYSICS 2013; 52:5-16. [PMID: 23100112 DOI: 10.1007/s00411-012-0436-7] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/13/2012] [Accepted: 10/11/2012] [Indexed: 06/01/2023]
Abstract
There is no clear evidence proving or disproving that ionising radiation is causally linked with neurodegenerative diseases such as Parkinson's and Alzheimer's. However, it is known that high doses of ionising radiation to the head (20-50 Gy) lead to severe learning and memory impairment which is characteristical for Alzheimer's. The cumulative doses of ionising radiation to the Western population are accruing, mostly due to the explosive growth of medical imaging procedures. Children are in particular prone to ionising radiation as the molecular processes within the brain are not completely finished. Furthermore, they have a long lifespan under risk. We wish to open a debate if such low doses of radiation exposure may lead to delayed long-term cognitive and other defects, albeit at a lower frequency than those observed during application of high doses. Further, we want to sensitise the society towards the risks of ionising radiation. To achieve these aims, we will recapitulate the known symptoms of Parkinson's and Alzheimer's on the molecular level and incorporate data of mainly low- and moderate-ionising radiation (<5 Gy). Thus, we want to highlight in general the potential similarities of both the neurodegenerative and radiation-induced pathways. We will propose a mechanistic model for radiation-induced neurodegeneration pointing out mitochondria as a key element. This includes effects of oxidative stress and neuroinflammation-all fundamental players of neurodegenerative diseases.
Collapse
Affiliation(s)
- Stefan J Kempf
- German Research Center for Environmental Health, Institute of Radiation Biology, Helmholtz Zentrum München, Ingolstaedter Landstrasse 1, 85764 Neuherberg, Germany
| | | | | | | |
Collapse
|
69
|
Bernier MO, Mezzarobba M, Maupu E, Caër-Lorho S, Brisse HJ, Laurier D, Brunelle F, Chatellier G. [Role of French hospital claims databases from care units in epidemiological studies: the example of the "Cohorte Enfant Scanner" study]. Rev Epidemiol Sante Publique 2012; 60:363-70. [PMID: 22981307 DOI: 10.1016/j.respe.2012.02.011] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2011] [Revised: 01/13/2012] [Accepted: 02/16/2012] [Indexed: 11/16/2022] Open
Abstract
BACKGROUND The "Cohorte Enfant Scanner", a study designed to investigate the risk of radiation-induced cancer after childhood exposure to CT (computed tomography) examinations, used clinical information contained in the "programme de médicalisation des systèmes d'information" (PMSI) database, the French hospital activities national program based upon diagnosis related groups (DRG). However, the quality and adequacy of the data for the specific needs of the study should be verified. The aim of our work was to estimate the percentage of the cohort's children identified in the PMSI database and to develop an algorithm to individualize the children with a cancer or a disease at risk of cancer from medical diagnoses provided by the DRGs database. METHODS Of the 1519 children from the "Cohorte Enfant Scanner", who had had a CT scan in the radiology department of a university hospital in 2002, a cross linkage was performed with the DRGs database. All hospitalizations over the period 2002-2009 were taken into account. An algorithm was constructed for the items "cancer" and "disease at risk for cancer" on a sample of 150 children. The algorithm was then tested on the entire population. RESULTS Overall, 74% of our population was identified in the DRGs database. The algorithm individualized cancer diagnoses with 91% sensitivity (95% confidence interval [95%CI]: 86%; 97%) and 98% specificity (95%CI: 97%; 99%) and 86% positive predictive value (95%CI: 80%; 93%). For the diagnosis of disease at risk for cancer, the sensitivity, specificity and positive predictive value were respectively 91% (95%CI: 84%; 98%), 94% (95%CI: 92%; 95%) and 52% (95%CI: 43%; 61%). CONCLUSION The DRG database identified with excellent sensitivity and specificity children with diagnoses of cancer or disease at risk for cancer. Hence, potential confounding factors related to the disease of the child can be taken into account for analyses performed with the cohort.
Collapse
Affiliation(s)
- M-O Bernier
- Laboratoire d'épidémiologie, institut de radioprotection et de sûreté nucléaire (IRSN), Fontenay-aux-Roses, France.
| | | | | | | | | | | | | | | |
Collapse
|
70
|
Jończyk-Potoczna K, Frankiewicz M, Warzywoda M, Strzyżewski K, Pawlak B. Low-dose protocol for head CT in evaluation of hydrocephalus in children. Pol J Radiol 2012; 77:7-11. [PMID: 22802860 PMCID: PMC3389960 DOI: 10.12659/pjr.882575] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2012] [Accepted: 02/11/2012] [Indexed: 11/09/2022] Open
Abstract
Background: A suspicion of ventriculo–peritoneal shunt failure is classified as the most common indication for CT in children with hydrocephalus. The main target of the study was to evaluate the diagnostic value of a low-dose protocol and to compare a total DLP received by patients in compared protocols. Material/Methods: Our retrospective analysis included 256 examinations performed in patients aged from 1 month to 18 years, with body mass ranging from 3 to 100 kg. The examinations were conducted in the years 2009–2011. A total number of 128 examinations were performed on the basis of the low-dose protocol and 128 according to a standard protocol using the Siemens SOMATOM Definition AS 128-slice scanner. Results/Conlusions: The analysis showed a full value of the diagnostic low-dose protocol with a simultaneous decrease of the total dose of DLP to the average of 40%. Application protocol with lower mAs in assessing the causes of ventriculo-peritoneal shunt failure in children with hydrocephalus is coherent with the valid principles of radiation protection in pediatrics and reduces the total DLP while maintaining a very good diagnostic value.
Collapse
Affiliation(s)
- Katarzyna Jończyk-Potoczna
- Department of Pediatric Radiology of the Chair of Radiology, Poznań University of Medical Sciences, Poznań, Poland
| | | | | | | | | |
Collapse
|
71
|
Maglione M, Montella S, Santamaria F. Chest CTs in primary ciliary dyskinesia: not too few, but not too many! Pediatr Pulmonol 2012; 47:733-5. [PMID: 22570095 DOI: 10.1002/ppul.22589] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/17/2012] [Accepted: 03/22/2012] [Indexed: 12/20/2022]
Affiliation(s)
- Marco Maglione
- Department of Pediatrics, Federico II University, Naples, Italy
| | | | | |
Collapse
|
72
|
Schweitzer T, Böhm H, Meyer-Marcotty P, Collmann H, Ernestus RI, Krauß J. Avoiding CT scans in children with single-suture craniosynostosis. Childs Nerv Syst 2012; 28:1077-82. [PMID: 22349960 DOI: 10.1007/s00381-012-1721-0] [Citation(s) in RCA: 59] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/20/2012] [Accepted: 02/08/2012] [Indexed: 10/28/2022]
Abstract
INTRODUCTION During the last decades, computed tomography (CT) has become the predominant imaging technique in the diagnosis of craniosynostosis. In most craniofacial centers, at least one three-dimensional (3D) computed tomographic scan is obtained in every case of suspected craniosynostosis. However, with regard to the risk of radiation exposure particularly in young infants, CT scanning and even plain radiography should be indicated extremely carefully. MATERIAL AND METHODS Our current diagnostic protocol in the management of single-suture craniosynostosis is mainly based on careful clinical examination with regard to severity and degree of the abnormality and on ophthalmoscopic surveillance. Imaging techniques consist of ultrasound examination in young infants while routine plain radiographs are usually postponed to the date of surgery or the end of the first year. CT and magnetic resonance imaging (MRI) are confined to special diagnostic problems rarely encountered in isolated craniosynostosis. The results of this approach were evaluated retrospectively in 137 infants who were referred to our outpatient clinic for evaluation and/or treatment of suspected single suture craniosynostosis or positional deformity during a 2-year period (2008-2009). RESULTS In 133 (97.1%) of the 137 infants, the diagnosis of single-suture craniosynostosis (n = 110) or positional plagiocephaly (n = 27) was achieved through clinical analysis only. Two further cases were classified by ultrasound, while the remaining two cases needed additional digital radiographs. In no case was CT scanning retrospectively considered necessary for establishing the diagnosis. Yet in 17.6% of cases, a cranial CT scan had already been performed elsewhere (n = 16) or had been definitely scheduled (n = 8). CONCLUSION CT scanning is rarely necessary for evaluation of single-suture craniosynostosis. Taking into account that there is a quantifiable risk of developing cancer in further lifetime, every single CT scan should be carefully indicated.
Collapse
Affiliation(s)
- T Schweitzer
- Department of Neurosurgery, Pediatric Neurosurgery, Craniofacial Center, University of Würzburg, Würzburg, Germany.
| | | | | | | | | | | |
Collapse
|