51
|
Aakhte M, Akhlaghi EA, Müller HAJ. SSPIM: a beam shaping toolbox for structured selective plane illumination microscopy. Sci Rep 2018; 8:10067. [PMID: 29968787 PMCID: PMC6030192 DOI: 10.1038/s41598-018-28389-8] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2018] [Accepted: 06/21/2018] [Indexed: 11/09/2022] Open
Abstract
Selective plane illumination microscopy (SPIM) represents a preferred method in dynamic tissue imaging, because it combines high spatiotemporal resolution with low phototoxicity. The OpenSPIM system was developed to provide an accessible and flexible microscope set-up for non-specialist users. Here, we report Structured SPIM (SSPIM), which offers an open-source, user-friendly and compact toolbox for beam shaping to be applied within the OpenSPIM platform. SSPIM is able to generate digital patterns for a wide range of illumination beams including static and spherical Gaussian beams, Bessel beams and Airy beams by controlling the pattern of a Spatial Light Modulator (SLM). In addition, SSPIM can produce patterns for structured illumination including incoherent and coherent array beams and tiling for all types of the supported beams. We describe the workflow of the toolbox and demonstrate its application by comparing experimental data with simulation results for a wide range of illumination beams. Finally, the capability of SSPIM is investigated by 3D imaging of Drosophila embryos using scanned Gaussian, Bessel and array beams. SSPIM provides an accessible toolbox to generate and optimize the desired beam patterns and helps adapting the OpenSPIM system towards a wider range of biological samples.
Collapse
Affiliation(s)
- Mostafa Aakhte
- Institute for Biology, Division of Developmental Genetics, University of Kassel, Heinrich-Plett Str. 40, 34132, Kassel, Germany.
| | - Ehsan A Akhlaghi
- Department of Physics, Institute for Advanced Studies in Basic Sciences (IASBS), Zanjan, 45137-66731, Iran.,Optics Research Center, Institute for Advanced Studies in Basic Sciences (IASBS), Zanjan, 45137-66731, Iran
| | - H-Arno J Müller
- Institute for Biology, Division of Developmental Genetics, University of Kassel, Heinrich-Plett Str. 40, 34132, Kassel, Germany.
| |
Collapse
|
52
|
Migliori B, Datta MS, Dupre C, Apak MC, Asano S, Gao R, Boyden ES, Hermanson O, Yuste R, Tomer R. Light sheet theta microscopy for rapid high-resolution imaging of large biological samples. BMC Biol 2018; 16:57. [PMID: 29843722 PMCID: PMC5975440 DOI: 10.1186/s12915-018-0521-8] [Citation(s) in RCA: 62] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2018] [Accepted: 04/23/2018] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Advances in tissue clearing and molecular labeling methods are enabling unprecedented optical access to large intact biological systems. These developments fuel the need for high-speed microscopy approaches to image large samples quantitatively and at high resolution. While light sheet microscopy (LSM), with its high planar imaging speed and low photo-bleaching, can be effective, scaling up to larger imaging volumes has been hindered by the use of orthogonal light sheet illumination. RESULTS To address this fundamental limitation, we have developed light sheet theta microscopy (LSTM), which uniformly illuminates samples from the same side as the detection objective, thereby eliminating limits on lateral dimensions without sacrificing the imaging resolution, depth, and speed. We present a detailed characterization of LSTM, and demonstrate its complementary advantages over LSM for rapid high-resolution quantitative imaging of large intact samples with high uniform quality. CONCLUSIONS The reported LSTM approach is a significant step for the rapid high-resolution quantitative mapping of the structure and function of very large biological systems, such as a clarified thick coronal slab of human brain and uniformly expanded tissues, and also for rapid volumetric calcium imaging of highly motile animals, such as Hydra, undergoing non-isomorphic body shape changes.
Collapse
Affiliation(s)
- Bianca Migliori
- Department of Biological Sciences, Columbia University, New York, NY, USA
- Department of Neuroscience, Karolinska Institutet, Stockholm,, Sweden
| | - Malika S Datta
- Department of Biological Sciences, Columbia University, New York, NY, USA
| | - Christophe Dupre
- Department of Biological Sciences, Columbia University, New York, NY, USA
- NeuroTechnology Center, Columbia University, New York, NY, USA
| | - Mehmet C Apak
- Department of Biological Sciences, Columbia University, New York, NY, USA
| | - Shoh Asano
- MIT Media Lab and McGovern Institute, Departments of Biological Engineering and Brain and Cognitive Sciences, MIT, Cambridge, MA, USA
- Pfizer Internal Medicine Research Unit, Cambridge, MA, 02139, USA
| | - Ruixuan Gao
- MIT Media Lab and McGovern Institute, Departments of Biological Engineering and Brain and Cognitive Sciences, MIT, Cambridge, MA, USA
| | - Edward S Boyden
- MIT Media Lab and McGovern Institute, Departments of Biological Engineering and Brain and Cognitive Sciences, MIT, Cambridge, MA, USA
| | - Ola Hermanson
- Department of Neuroscience, Karolinska Institutet, Stockholm,, Sweden
| | - Rafael Yuste
- Department of Biological Sciences, Columbia University, New York, NY, USA
- NeuroTechnology Center, Columbia University, New York, NY, USA
- Data Science Institute, Columbia University, New York, NY, USA
| | - Raju Tomer
- Department of Biological Sciences, Columbia University, New York, NY, USA.
- NeuroTechnology Center, Columbia University, New York, NY, USA.
- Data Science Institute, Columbia University, New York, NY, USA.
| |
Collapse
|
53
|
Gustavsson AK, Petrov PN, Moerner WE. Light sheet approaches for improved precision in 3D localization-based super-resolution imaging in mammalian cells [Invited]. OPTICS EXPRESS 2018; 26:13122-13147. [PMID: 29801343 PMCID: PMC6005674 DOI: 10.1364/oe.26.013122] [Citation(s) in RCA: 37] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/26/2018] [Accepted: 03/30/2018] [Indexed: 05/08/2023]
Abstract
The development of imaging techniques beyond the diffraction limit has paved the way for detailed studies of nanostructures and molecular mechanisms in biological systems. Imaging thicker samples, such as mammalian cells and tissue, in all three dimensions, is challenging due to increased background and volumes to image. Light sheet illumination is a method that allows for selective irradiation of the image plane, and its inherent optical sectioning capability allows for imaging of biological samples with reduced background, photobleaching, and photodamage. In this review, we discuss the advantage of combining single-molecule imaging with light sheet illumination. We begin by describing the principles of single-molecule localization microscopy and of light sheet illumination. Finally, we present examples of designs that successfully have married single-molecule super-resolution imaging with light sheet illumination for improved precision in mammalian cells.
Collapse
|
54
|
Elisa Z, Toon B, De Smedt SC, Katrien R, Kristiaan N, Kevin B. Technical implementations of light sheet microscopy. Microsc Res Tech 2018; 81:941-958. [PMID: 29322581 DOI: 10.1002/jemt.22981] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2017] [Revised: 11/14/2017] [Accepted: 12/11/2017] [Indexed: 12/14/2022]
Abstract
Fluorescence-based microscopy is among the most successful methods in biological studies. It played a critical role in the visualization of subcellular structures and in the analysis of complex cellular processes, and it is nowadays commonly employed in genetic and drug screenings. Among the fluorescence-based microscopy techniques, light sheet fluorescence microscopy (LSFM) has shown a quite interesting set of benefits. The technique combines the speed of epi-fluorescence acquisition with the optical sectioning capability typical of confocal microscopes. Its unique configuration allows the excitation of only a thin plane of the sample, thus fast, high resolution imaging deep inside tissues is nowadays achievable. The low peak intensity with which the sample is illuminated diminishes phototoxic effects and decreases photobleaching of fluorophores, ensuring data collection for days with minimal adverse consequences on the sample. It is no surprise that LSFM applications have raised in just few years and the technique has been applied to study a wide variety of samples, from whole organism, to tissues, to cell clusters, and single cells. As a consequence, in recent years numerous set-ups have been developed, each one optimized for the type of sample in use and the requirements of the question at hand. Hereby, we aim to review the most advanced LSFM implementations to assist new LSFM users in the choice of the LSFM set-up that suits their needs best. We also focus on new commercial microscopes and "do-it-yourself" strategies; likewise we review recent designs that allow a swift integration of LSFM on existing microscopes.
Collapse
Affiliation(s)
- Zagato Elisa
- Laboratory of General Biochemistry and Physical Pharmacy, Center for Nano- and Biophotonics, Ghent University, Belgium
| | - Brans Toon
- Laboratory of General Biochemistry and Physical Pharmacy, Center for Nano- and Biophotonics, Ghent University, Belgium
| | - Stefaan C De Smedt
- Laboratory of General Biochemistry and Physical Pharmacy, Ghent University, Belgium
| | - Remaut Katrien
- Laboratory of General Biochemistry and Physical Pharmacy, Ghent University, Belgium
| | - Neyts Kristiaan
- Liquid Crystals and Photonics Group, Center for Nano- and Biophotonics, Ghent University, Belgium
| | - Braeckmans Kevin
- Laboratory of General Biochemistry and Physical Pharmacy, Center for Nano- and Biophotonics, Ghent University, Belgium
| |
Collapse
|
55
|
Automated video-mosaicking approach for confocal microscopic imaging in vivo: an approach to address challenges in imaging living tissue and extend field of view. Sci Rep 2017; 7:10759. [PMID: 28883434 PMCID: PMC5589933 DOI: 10.1038/s41598-017-11072-9] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2017] [Accepted: 08/11/2017] [Indexed: 12/12/2022] Open
Abstract
We describe a computer vision-based mosaicking method for in vivo videos of reflectance confocal microscopy (RCM). RCM is a microscopic imaging technique, which enables the users to rapidly examine tissue in vivo. Providing resolution at cellular-level morphology, RCM imaging combined with mosaicking has shown to be highly sensitive and specific for non-invasively guiding skin cancer diagnosis. However, current RCM mosaicking techniques with existing microscopes have been limited to two-dimensional sequences of individual still images, acquired in a highly controlled manner, and along a specific predefined raster path, covering a limited area. The recent advent of smaller handheld microscopes is enabling acquisition of videos, acquired in a relatively uncontrolled manner and along an ad-hoc arbitrarily free-form, non-rastered path. Mosaicking of video-images (video-mosaicking) is necessary to display large areas of tissue. Our video-mosaicking methods addresses this need. The method can handle unique challenges encountered during video capture such as motion blur artifacts due to rapid motion of the microscope over the imaged area, warping in frames due to changes in contact angle and varying resolution with depth. We present test examples of video-mosaics of melanoma and non-melanoma skin cancers, to demonstrate potential clinical utility.
Collapse
|
56
|
Power RM, Huisken J. A guide to light-sheet fluorescence microscopy for multiscale imaging. Nat Methods 2017; 14:360-373. [DOI: 10.1038/nmeth.4224] [Citation(s) in RCA: 405] [Impact Index Per Article: 57.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2016] [Accepted: 02/16/2017] [Indexed: 12/18/2022]
|
57
|
Diagonally Scanned Light-Sheet Microscopy for Fast Volumetric Imaging of Adherent Cells. Biophys J 2016; 110:1456-65. [PMID: 27028654 PMCID: PMC4816690 DOI: 10.1016/j.bpj.2016.01.029] [Citation(s) in RCA: 36] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2015] [Revised: 12/31/2015] [Accepted: 01/28/2016] [Indexed: 11/23/2022] Open
Abstract
In subcellular light-sheet fluorescence microscopy (LSFM) of adherent cells, glass substrates are advantageously rotated relative to the excitation and emission light paths to avoid glass-induced optical aberrations. Because cells are spread across the sample volume, three-dimensional imaging requires a light-sheet with a long propagation length, or rapid sample scanning. However, the former degrades axial resolution and/or optical sectioning, while the latter mechanically perturbs sensitive biological specimens on pliant biomimetic substrates (e.g., collagen and basement membrane). Here, we use aberration-free remote focusing to diagonally sweep a narrow light-sheet along the sample surface, enabling multicolor imaging with high spatiotemporal resolution. Further, we implement a dithered Gaussian lattice to minimize sample-induced illumination heterogeneities, significantly improving signal uniformity. Compared with mechanical sample scanning, we drastically reduce sample oscillations, allowing us to achieve volumetric imaging at speeds of up to 3.5 Hz for thousands of Z-stacks. We demonstrate the optical performance with live-cell imaging of microtubule and actin cytoskeletal dynamics, phosphoinositide signaling, clathrin-mediated endocytosis, polarized blebbing, and endocytic vesicle sorting. We achieve three-dimensional particle tracking of clathrin-associated structures with velocities up to 4.5 μm/s in a dense intracellular environment, and show that such dynamics cannot be recovered reliably at lower volumetric image acquisition rates using experimental data, numerical simulations, and theoretical modeling.
Collapse
|
58
|
Abstract
AbstractLive-cell and live-tissue imaging using fluorescence optical microscopes presents an inherent trade-off between image quality and photodamage. Spatially-controlled illumination microscopy (SCIM) aims to strike the right balance between obtaining good image quality and minimizing the risk of photodamage. In traditional imaging, illumination is performed with a spatially-uniform light dose resulting in spatially-variable detected signals. SCIM adopts an alternative imaging approach where illumination is performed with a spatially-variable light dose resulting in spatially-uniform detected signals. The actual image information of the biological specimen in SCIM is predominantly encoded in the illumination profile. SCIM uses real-time spatial control of illumination in the imaging of fluorescent biological specimens. This alternative imaging paradigm reduces the overall illumination light dose during imaging, which facilitates prolonged imaging of live biological specimens by minimizing photodamage without compromising image quality. Additionally, the dynamic range of a SCIM image is no longer limited by the dynamic range of the detector (or camera), since it employs a uniform detection strategy. The large dynamic range of SCIM is predominantly determined by the illumination profile, and is advantageous for imaging both live and fixed biological specimens. In the present review, the concept and working mechanisms of SCIM are discussed, together with its application in various types of optical microscopes.
Collapse
|
59
|
Zou J, Pyykkö I, Hyttinen J. Inner ear barriers to nanomedicine-augmented drug delivery and imaging. J Otol 2016; 11:165-177. [PMID: 29937826 PMCID: PMC6002620 DOI: 10.1016/j.joto.2016.11.002] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2016] [Revised: 11/15/2016] [Accepted: 11/18/2016] [Indexed: 02/08/2023] Open
Abstract
There are several challenges to inner ear drug delivery and imaging due to the existence of tight biological barriers to the target structure and the dense bone surrounding it. Advances in imaging and nanomedicine may provide knowledge for overcoming the existing limitations to both the diagnosis and treatment of inner ear diseases. Novel techniques have improved the efficacy of drug delivery and targeting to the inner ear, as well as the quality and accuracy of imaging this structure. In this review, we will describe the pathways and biological barriers of the inner ear regarding drug delivery, the beneficial applications and limitations of the imaging techniques available for inner ear research, the behavior of engineered nanomaterials in inner ear applications, and future perspectives for nanomedicine-based inner ear imaging.
Collapse
Affiliation(s)
- Jing Zou
- Department of Otolaryngology – Head and Neck Surgery, Center for Otolaryngology – Head & Neck Surgery of Chinese PLA, Changhai Hospital, Second Military Medical University, Shanghai, China
- Hearing and Balance Research Unit, Field of Otolaryngology, School of Medicine, University of Tampere, Tampere, Finland
| | - Ilmari Pyykkö
- Hearing and Balance Research Unit, Field of Otolaryngology, School of Medicine, University of Tampere, Tampere, Finland
| | - Jari Hyttinen
- Department of Electronics and Communications Engineering, BioMediTech, Tampere University of Technology, Tampere, Finland
| |
Collapse
|
60
|
Zhang P, Phipps ME, Goodwin PM, Werner JH. Light-sheet microscopy by confocal line scanning of dual-Bessel beams. JOURNAL OF BIOMEDICAL OPTICS 2016; 21:100502. [PMID: 27779273 DOI: 10.1117/1.jbo.21.10.100502] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/04/2016] [Accepted: 10/06/2016] [Indexed: 05/15/2023]
Abstract
We have developed a light-sheet microscope that uses confocal scanning of dual-Bessel beams for illumination. A digital micromirror device (DMD) is placed in the intermediate image plane of the objective used to collect fluorescence and is programmed with two lines of pixels in the “on” state such that the DMD functions as a spatial filter to reject the out-of-focus background generated by the side-lobes of the Bessel beams. The optical sectioning and out-of-focus background rejection capabilities of this microscope were demonstrated by imaging of fluorescently stained actin in human A431 cells. The dual-Bessel beam system enables twice as many photons to be detected per imaging scan, which is useful for low light applications (e.g., single-molecule localization) or imaging at high speed with a superior signal to noise. While demonstrated for two Bessel beams, this approach is scalable to a larger number of beams.
Collapse
Affiliation(s)
- Pengfei Zhang
- Washington University in St. Louis, Department of Biomedical Engineering, Optical Imaging Laboratory, One Brookings Drive, St. Louis, Missouri 63130-4899, United States
| | - Mary E Phipps
- Center for Integrated Nanotechnologies, Los Alamos National Laboratory, Mail Stop G755, Los Alamos, New Mexico 87545, United States
| | - Peter M Goodwin
- Center for Integrated Nanotechnologies, Los Alamos National Laboratory, Mail Stop G755, Los Alamos, New Mexico 87545, United States
| | - James H Werner
- Center for Integrated Nanotechnologies, Los Alamos National Laboratory, Mail Stop G755, Los Alamos, New Mexico 87545, United States
| |
Collapse
|
61
|
Wulstein DM, Regan KE, Robertson-Anderson RM, McGorty R. Light-sheet microscopy with digital Fourier analysis measures transport properties over large field-of-view. OPTICS EXPRESS 2016; 24:20881-94. [PMID: 27607692 PMCID: PMC5946909 DOI: 10.1364/oe.24.020881] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/07/2023]
Abstract
Using light-sheet microscopy combined with digital Fourier methods we probe the dynamics of colloidal samples and DNA molecules. This combination, referred to as selective-plane illumination differential dynamic microscopy (SPIDDM), has the benefit of optical sectioning to study, with minimal photobleaching, thick samples allowing us to measure the diffusivity of colloidal particles at high volume fractions. Further, SPIDDM exploits the inherent spatially-varying thickness of Gaussian light-sheets. Where the excitation sheet is most focused, we capture high spatial frequency dynamics as the signal-to-background is high. In thicker regions, we capture the slower dynamics as diffusion out of the sheet takes longer.
Collapse
|
62
|
Daetwyler S, Huisken J. Fast Fluorescence Microscopy with Light Sheets. THE BIOLOGICAL BULLETIN 2016; 231:14-25. [PMID: 27638692 DOI: 10.1086/689588] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
In light sheet microscopy, optical sectioning by selective fluorescence excitation with a sheet of light is combined with fast full-frame acquisition. This illumination scheme provides minimal photobleaching and phototoxicity. Complemented with remote focusing and multi-view acquisition, light sheet microscopy is the method of choice for acquisition of very fast biological processes, large samples, and high-throughput applications in areas such as neuroscience, plant biology, and developmental biology. This review explains why light sheet microscopes are much faster and gentler than other established fluorescence microscopy techniques. New volumetric imaging schemes and highlights of selected biological applications are also discussed.
Collapse
Affiliation(s)
- Stephan Daetwyler
- Max Planck Institute of Molecular Cell Biology and Genetics, Pfotenhauerstrasse 108, 01307 Dresden, Germany
| | - Jan Huisken
- Max Planck Institute of Molecular Cell Biology and Genetics, Pfotenhauerstrasse 108, 01307 Dresden, Germany
| |
Collapse
|
63
|
Dean KM, Roudot P, Welf ES, Danuser G, Fiolka R. Deconvolution-free Subcellular Imaging with Axially Swept Light Sheet Microscopy. Biophys J 2016; 108:2807-15. [PMID: 26083920 PMCID: PMC4472079 DOI: 10.1016/j.bpj.2015.05.013] [Citation(s) in RCA: 131] [Impact Index Per Article: 16.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2015] [Revised: 05/08/2015] [Accepted: 05/12/2015] [Indexed: 11/30/2022] Open
Abstract
The use of propagation invariant Bessel beams has enabled high-resolution subcellular light sheet fluorescence microscopy. However, the energy within the concentric side lobe structure of Bessel beams increases significantly with propagation length, generating unwanted out-of-focus fluorescence that enforces practical limits on the imaging field of view size. Here, we present a light sheet fluorescence microscope that achieves 390 nm isotropic resolution and high optical sectioning strength (i.e., out-of-focus blur is strongly suppressed) over large field of views, without the need for structured illumination or deconvolution-based postprocessing. We demonstrate simultaneous dual-color, high-contrast, and high-dynamic-range time-lapse imaging of migrating cells in complex three-dimensional microenvironments, three-dimensional tracking of clathrin-coated pits, and long-term imaging spanning >10 h and encompassing >2600 time points.
Collapse
Affiliation(s)
- Kevin M Dean
- Department of Cell Biology, University of Texas Southwestern Medical Center, Dallas, Texas
| | - Philippe Roudot
- Department of Cell Biology, University of Texas Southwestern Medical Center, Dallas, Texas
| | - Erik S Welf
- Department of Cell Biology, University of Texas Southwestern Medical Center, Dallas, Texas
| | - Gaudenz Danuser
- Department of Cell Biology, University of Texas Southwestern Medical Center, Dallas, Texas
| | - Reto Fiolka
- Department of Cell Biology, University of Texas Southwestern Medical Center, Dallas, Texas.
| |
Collapse
|
64
|
Imaging multicellular specimens with real-time optimized tiling light-sheet selective plane illumination microscopy. Nat Commun 2016; 7:11088. [PMID: 27004937 PMCID: PMC4814582 DOI: 10.1038/ncomms11088] [Citation(s) in RCA: 80] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2015] [Accepted: 02/19/2016] [Indexed: 02/07/2023] Open
Abstract
Despite the progress made in selective plane illumination microscopy, high-resolution 3D live imaging of multicellular specimens remains challenging. Tiling light-sheet selective plane illumination microscopy (TLS-SPIM) with real-time light-sheet optimization was developed to respond to the challenge. It improves the 3D imaging ability of SPIM in resolving complex structures and optimizes SPIM live imaging performance by using a real-time adjustable tiling light sheet and creating a flexible compromise between spatial and temporal resolution. We demonstrate the 3D live imaging ability of TLS-SPIM by imaging cellular and subcellular behaviours in live C. elegans and zebrafish embryos, and show how TLS-SPIM can facilitate cell biology research in multicellular specimens by studying left-right symmetry breaking behaviour of C. elegans embryos. Selective plane illumination microscopy (SPIM) is capable of high-resolution, high-speed 3D imaging of single cells, but application to multicellular samples is challenging. Here the authors develop tiling light sheet SPIM to image large multicellular specimens in 3D with subcellular resolution.
Collapse
|
65
|
Golub I, Chebbi B, Golub J. Toward the optical "magic carpet": reducing the divergence of a light sheet below the diffraction limit. OPTICS LETTERS 2015; 40:5121-4. [PMID: 26512534 DOI: 10.1364/ol.40.005121] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/15/2023]
Abstract
In 3D, diffraction-free or Bessel beams are well known and have found applications in diverse fields. An analog in 2D, or pseudonondiffracting (PND) beams, is a nontrivial problem, and existing methods suffer from deficiencies. For example, Airy beams are not highly localized, some PND beams have significant side lobes, and a cosine beam has to be truncated by a very narrow aperture thus discarding most of the energy. We show, both theoretically and experimentally, that it is possible to generate a quasi-nondiffracting 2D light beam in a simple and efficient fashion. This is achieved by placing a mask consisting of a pair of double slits on a cylindrical lens. The applications include light sheet microscopy/optical sectioning and particle manipulation.
Collapse
|
66
|
Hedde PN, Gratton E. Active focus stabilization for upright selective plane illumination microscopy. OPTICS EXPRESS 2015; 23:14707-14. [PMID: 26072829 PMCID: PMC4523369 DOI: 10.1364/oe.23.014707] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/13/2015] [Revised: 05/20/2015] [Accepted: 05/20/2015] [Indexed: 05/18/2023]
Abstract
Due to its sectioning capability, large field of view, and minimal light exposure, selective plane illumination microscopy has become the preferred choice for 3D time lapse imaging. Single cells in a dish can be conveniently imaged using an upright/inverted configuration. However, for measurements on long time scales (hours to days), mechanical drift is a problem; especially for studies of mammalian cells that typically require heating to 37°C which causes a thermal gradient across the instrument. Since the light sheet diverges towards the edges of the field of view, such a drift leads to a decrease in axial resolution over time. Or, even worse, the specimen could move out of the imaging volume. Here, we present a simple, cost-effective way to stabilize the axial position using the microscope camera to track the sample position. Thereby, sample loss is prevented and an optimal axial resolution is maintained by keeping the sample at the position where the light sheet is at its thinnest. We demonstrate the virtue of our approach by measurements of the light sheet thickness and 3D time lapse imaging of a cell monolayer at physiological conditions.
Collapse
|