101
|
Saku K, Yokota S, Nishikawa T, Kinugawa K. Interventional heart failure therapy: A new concept fighting against heart failure. J Cardiol 2021; 80:101-109. [PMID: 34924236 DOI: 10.1016/j.jjcc.2021.11.018] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/08/2021] [Accepted: 11/24/2021] [Indexed: 10/19/2022]
Abstract
Heart failure is a progressive disease that is associated with repeated exacerbations and hospitalizations. The rapid increase in the number of heart failure patients is a global health problem known as the 'heart failure pandemic'. To control the pandemic, multifaceted approaches are essential, ranging from prevention of onset to long-term disease management. Especially in patients with moderate to severe heart failure (stages C and D), surgical and catheter-based interventions are prerequisites for saving lives, preserving cardiac function, improving quality of life (QOL), and prognosis. In addition, various new medical technologies for these interventions have been clinically applied and have been shown to be effective against symptoms and improve the QOL and prognosis of patients with heart failure. Furthermore, the concept of interventional heart failure (IHF) therapy, which considers heart recovery and prevention of worsening of heart failure via multidisciplinary treatment using surgical, catheter interventions, and mechanical circulatory support devices, has been proposed worldwide. This review discusses the importance of IHF therapy in heart failure management, recent changes in interventional technologies and strategies for patients with heart failure, and worldwide education attempts for IHF specialists.
Collapse
Affiliation(s)
- Keita Saku
- Department of Cardiovascular Dynamics, National Cerebral and Cardiovascular Center Research Institute, Suita, Japan.
| | - Shohei Yokota
- Department of Cardiovascular Dynamics, National Cerebral and Cardiovascular Center Research Institute, Suita, Japan
| | - Takuya Nishikawa
- Department of Cardiovascular Dynamics, National Cerebral and Cardiovascular Center Research Institute, Suita, Japan
| | | |
Collapse
|
102
|
Ogano M, Tsuboi I, Tanabe J. Cardiac resynchronization therapy for electrical dyssynchrony with a narrow QRS duration and left anterior hemiblock. HeartRhythm Case Rep 2021; 7:829-832. [PMID: 34987969 PMCID: PMC8695277 DOI: 10.1016/j.hrcr.2021.09.001] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022] Open
Affiliation(s)
- Michio Ogano
- Address reprint requests and correspondence: Dr Michio Ogano, Division of Cardiovascular Medicine, Shizuoka Medical Center, 762-1 Nagasawa, Shimizu, Sunto Shizuoka 4110906, Japan.
| | | | | |
Collapse
|
103
|
CRT Efficacy in "Mid-Range" QRS Duration Among Asians Contrasted to Non-Asians, and Influence of Height. JACC Clin Electrophysiol 2021; 8:211-221. [PMID: 34838518 DOI: 10.1016/j.jacep.2021.09.012] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2021] [Revised: 09/27/2021] [Accepted: 09/29/2021] [Indexed: 11/20/2022]
Abstract
OBJECTIVES The purpose of this study was to test the hypotheses that cardiac resynchronization therapy (CRT) efficacy differed among Asians compared with non-Asian populations, differed between QRS duration (QRSd) ranges 120-149 and ≥150 ms, and was influenced by height in the multinational ADVANCE CRT trial. BACKGROUND CRT guidelines, derived from trials among U.S./European patients, assign weaker recommendations to those with midrange QRSd (QRSd <150 ms). Patient height may modulate CRT efficacy. Together, these may affect CRT prescription and efficacy in Asia. METHODS CRT response was assessed using the Clinical Composite Score 6 months postimplant (n = 934). Heart failure events and cardiac deaths were reported until 12 months. Asian and non-Asian patients were compared overall, by QRSd <150 ms (Asian n = 71 vs non-Asian n = 248), and QRSd ≥150 ms (Asian n = 180 vs non-Asian n = 435) and by height. RESULTS Asians comprised 27% (251 of 934) of the primary study population. More Asians had QRSd ≥150 ms (72% [180 of 251] vs 64% [435 of 683] in non-Asian patients; P = 0.022). Overall CRT response was better in Asians vs non-Asians (Clinical Composite Score 85% vs 65%; P <0.001), and following QRSd dichotomization (QRSd <150 ms: 80% vs 59%; P <0.001; QRS ≥150 ms: 86% vs 69%; P < 0.001). HF events and cardiac deaths were fewer in Asians irrespective of QRSd (P < 0.001). Stepwise multivariable analysis indicated that in group QRSd <150 ms, nonischemic cardiomyopathy, number of other comorbidities (0-1 vs ≥4), and atrial fibrillation influenced CRT response. The trend favoring Asian race (OR: 1.46; 95% CI: 0.72-2.95) was eliminated (OR: 1.00; 95% CI: 0.47-2.11) when height or QRSd/height were included (QRSd/height P = 0.006; OR: 1.64; 95% CI: 1.15-2.35). In QRSd <150 ms, probability of CRT response diminished as height increased, but increased with QRSd/height, in both Asians and non-Asians. In QRSd ≥150 ms, height or QRSd/height had minimal effect in Asians or non-Asians. CONCLUSIONS Height modulates CRT efficacy among patients with QRSd <150 ms and contributes to high probability of benefit from CRT among Asians. CRT should be encouraged among Asian patients with midrange QRSd. (Advance Cardiac Resynchronization Therapy [CRT] Registry; NCT01805154).
Collapse
|
104
|
Identification of high priority focal activations in persistent atrial fibrillation using a novel mapping strategy. Heart Vessels 2021; 37:840-853. [PMID: 34708268 DOI: 10.1007/s00380-021-01977-x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/01/2021] [Accepted: 10/22/2021] [Indexed: 10/20/2022]
Abstract
Focal activation is believed to be an atrial fibrillation (AF) driver; however, little is known about whether all focal activations are necessary for AF persistence. The purpose of this study was to assess the electrical nature of focal activation and identify high-priority focal activations using a novel mapping system (CARTOFINDER). Thirty-five patients with persistent AF who underwent catheter ablation were assessed. Cycle length (CL) and CL standard deviation (CLSD) on unipolar recordings and voltage amplitude and electrogram morphologies on bipolar recordings were evaluated at all points of interest. The most frequent CL at each mapping site was defined as the dominant CL. We identified dominant focal activations (DFAs) that had a shorter dominant CL on the integrated CARTOFINDER map. The effect of elimination of DFAs on AF maintenance was assessed by the composite endpoint (termination to sinus rhythm, organization of the rhythm to atrial tachycardia, and AF CL slowing). In all, 450 focal activations were identified among 10,868 points, and 50.4% of focal activations were DFAs. Focal activations showed relatively long CL and regularity with short CLSD. Most focal activations showed an isoelectric baseline and were located outside of the fractionated electrogram area. Both DFAs and non-DFAs were typically observed in the normal voltage range. Elimination of DFAs was achieved in 19 (54.3%) patients, with a remarkable impact on AF maintenance (68.4% vs. 25.0%, p = 0.018). In conclusion, DFAs may play an important role in AF maintenance and could be an attractive therapeutic target for AF.
Collapse
|
105
|
Makino Y, Mizutani Y, Yamashita D, Yonekawa J, Satake A, Kurobe M, Hiramatsu T, Ichimiya H, Uchida Y, Watanabe J, Kanashiro M, Ichimiya S, Yanagisawa S, Inden Y, Murohara T. Cryoballoon ablation for atrial fibrillation without the use of a contrast medium: a combination of the intracardiac echocardiography and pressure wave monitoring guided approach. Heart Vessels 2021; 37:765-774. [PMID: 34636968 DOI: 10.1007/s00380-021-01963-3] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/29/2021] [Accepted: 10/08/2021] [Indexed: 12/01/2022]
Abstract
In cryoballoon ablation (CBA), a contrast medium is commonly used to confirm balloon occlusion of the pulmonary veins (PVs). However, a contrast medium cannot always be used in patients with renal dysfunction and allergy. The present study aimed to assess the efficacy and safety of CBA without the use of a contrast medium. We retrospectively examined consecutive patients with paroxysmal atrial fibrillation (PAF) who underwent first-time CBA. We compared the procedural results and outcomes in patients for whom a contrast medium was used (contrast group) and those from whom a contrast medium was not used (non-contrast group). In the non-contrast group, we used saline injection on the intracardiac echocardiography and pressure wave monitoring for PV occlusion. Fifty patients (200 PVs) and 22 patients (88 PVs) underwent CBA with and without a contrast medium, respectively. The success rate of PV isolation with CBA alone was 93% and 90% in the non-contrast and contrast groups, respectively (p = 0.40). The fluoroscopy time and nadir temperature were significantly lower in the non-contrast group as compared to that in the contrast group. The recurrence rate 1 year after ablation did not differ between the two groups (18% vs. 18%, p > 0.99). Furthermore, the number of reconnected PVs in patients with recurrence was significantly lower in the non-contrast group than in the contrast group (6% vs. 36%, p = 0.017). In conclusion, CBA using the intracardiac echocardiography and pressure monitoring approach without the use of a contrast medium was safe and efficient.
Collapse
Affiliation(s)
- Yuichiro Makino
- Department of Cardiology, Yokkaichi Municipal Hospital, 2-2-37, Shibata, Yokkaichi, Mie, Japan.
- Department of Cardiology, Nagoya University Graduate School of Medicine, Nagoya, Aichi, Japan.
| | - Yoshiaki Mizutani
- Department of Cardiology, Yokkaichi Municipal Hospital, 2-2-37, Shibata, Yokkaichi, Mie, Japan
| | - Daiki Yamashita
- Department of Cardiology, Yokkaichi Municipal Hospital, 2-2-37, Shibata, Yokkaichi, Mie, Japan
| | - Jun Yonekawa
- Department of Cardiology, Yokkaichi Municipal Hospital, 2-2-37, Shibata, Yokkaichi, Mie, Japan
| | - Akinori Satake
- Department of Cardiology, Yokkaichi Municipal Hospital, 2-2-37, Shibata, Yokkaichi, Mie, Japan
| | - Masanari Kurobe
- Department of Cardiology, Yokkaichi Municipal Hospital, 2-2-37, Shibata, Yokkaichi, Mie, Japan
| | - Takatsugu Hiramatsu
- Department of Cardiology, Yokkaichi Municipal Hospital, 2-2-37, Shibata, Yokkaichi, Mie, Japan
| | - Hitoshi Ichimiya
- Department of Cardiology, Yokkaichi Municipal Hospital, 2-2-37, Shibata, Yokkaichi, Mie, Japan
| | - Yasuhiro Uchida
- Department of Cardiology, Yokkaichi Municipal Hospital, 2-2-37, Shibata, Yokkaichi, Mie, Japan
| | - Junji Watanabe
- Department of Cardiology, Yokkaichi Municipal Hospital, 2-2-37, Shibata, Yokkaichi, Mie, Japan
| | - Masaaki Kanashiro
- Department of Cardiology, Yokkaichi Municipal Hospital, 2-2-37, Shibata, Yokkaichi, Mie, Japan
| | - Satoshi Ichimiya
- Department of Cardiology, Yokkaichi Municipal Hospital, 2-2-37, Shibata, Yokkaichi, Mie, Japan
| | - Satoshi Yanagisawa
- Department of Cardiology, Nagoya University Graduate School of Medicine, Nagoya, Aichi, Japan
| | - Yasuya Inden
- Department of Cardiology, Nagoya University Graduate School of Medicine, Nagoya, Aichi, Japan
| | - Toyoaki Murohara
- Department of Cardiology, Nagoya University Graduate School of Medicine, Nagoya, Aichi, Japan
| |
Collapse
|
106
|
Minami Y, Kikuchi N, Shiga T, Suzuki A, Shoda M, Hagiwara N. Incidence and predictors of early and late sudden cardiac death in hospitalized Japanese patients with new-onset systolic heart failure. J Arrhythm 2021; 37:1148-1155. [PMID: 34621413 PMCID: PMC8485812 DOI: 10.1002/joa3.12618] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2021] [Revised: 07/22/2021] [Accepted: 08/07/2021] [Indexed: 11/11/2022] Open
Abstract
BACKGROUND Patients with heart failure (HF) and low left ventricular ejection fraction (LVEF) are at high risk of sudden cardiac death (SCD). Optimal HF treatment can improve LVEF and reduce the risk of SCD. The aim of this study was to evaluate the incidence and predictors of SCD in Japanese patients with new-onset systolic HF and to investigate factors that affect LVEF improvement. METHODS We retrospectively studied 174 consecutive hospitalized patients with new-onset HF and LVEF ≤35% (median age, 66 years; men, 71%). The primary outcome was a composite of SCD, sustained ventricular arrhythmias, and appropriate implantable cardioverter-defibrillator therapy. RESULTS The cumulative rates of meeting of the primary outcome at 3, 12, and 36 months after discharge were 3.9%, 8.1%, and 10.5%, respectively. Atrial fibrillation was a significant predictor of the primary outcome within 12 months after discharge (odds ratio, 5.87; 95% confidence interval [CI], 1.60-21.57). Among 104 patients who completed follow-up echocardiography within 12 months after discharge, changes in LVEF were inversely associated with SCD (odds ratio/1% increase, 0.78; 95% CI, 0.65-0.93). A QRS duration <130 ms and a B-type natriuretic peptide level <170 pg/mL were predictors of LVEF improvement to >35% (odds ratio, 3.69; 95% CI, 1.15-11.77; odds ratio, 3.19; 95% CI, 1.33-7.69, respectively). CONCLUSIONS Our results showed a high incidence of meeting of the primary outcome within 12 months after discharge in hospitalized patients with new-onset systolic HF. An improved LVEF may reduce the risk of late SCD.
Collapse
Affiliation(s)
- Yoshiaki Minami
- Department of Cardiology Tokyo Women's Medical University Tokyo Japan
| | - Noriko Kikuchi
- Department of Cardiology Tokyo Women's Medical University Tokyo Japan
| | - Tsuyoshi Shiga
- Department of Cardiology Tokyo Women's Medical University Tokyo Japan
- Department of Clinical Pharmacology and Therapeutics The Jikei University School of Medicine Tokyo Japan
| | - Atsushi Suzuki
- Department of Cardiology Tokyo Women's Medical University Tokyo Japan
| | - Morio Shoda
- Clinical Research Division for Heart Rhythm Management Tokyo Women's Medical University Tokyo Japan
| | - Nobuhisa Hagiwara
- Department of Cardiology Tokyo Women's Medical University Tokyo Japan
| |
Collapse
|
107
|
Mizutani Y, Yanagisawa S, Kanashiro M, Yamashita D, Yonekawa J, Makino Y, Hiramatsu T, Ichimiya H, Uchida Y, Watanabe J, Ichimiya S, Inden Y, Murohara T. Earliest pulmonary vein potential-guided cryoballoon ablation is associated with better clinical outcomes than conventional cryoballoon ablation: A result from two randomized clinical studies. J Cardiovasc Electrophysiol 2021; 32:2933-2942. [PMID: 34535938 DOI: 10.1111/jce.15246] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/06/2021] [Revised: 08/20/2021] [Accepted: 09/06/2021] [Indexed: 12/20/2022]
Abstract
INTRODUCTION With regard to short-term outcome in atrial fibrillation (AF), the benefit of cryoballoon ablation (CBA) by pressing a balloon against the earliest pulmonary vein (PV) potential site during PV isolation (earliest potential [EP]-guided CBA) has been previously demonstrated. The present study aimed to evaluate the long-term outcome of the EP-guided CBA. METHODS AND RESULTS This study included 136 patients from two randomized studies, who underwent CBA for paroxysmal AF for the first time. Patients were randomly assigned to the EP-guided and conventional CBA groups in each study. In the EP-guided CBA group, we pressed a balloon against the EP site when the time-to-isolation (TTI) after cryoapplication exceeded 60 and 45 s in the first and second studies, respectively. We compared the clinical outcomes for 1 year after the procedure between the EP-guided CBA group (68 patients) and the conventional CBA group (68 patients). The primary endpoint was the recurrence of atrial arrhythmia after ablation. No significant differences in baseline characteristics were observed between the two groups. Compared with the conventional CBA group, the EP-guided CBA group had a significantly higher success rate at TTI ≤ 90 s (98.5% vs. 90.0%, p < .001); lower touch-up rate and total cryoapplication; and shorter procedure time, and fluoroscopy time. The recurrence at 1 year after ablation was significantly lower in the EP-guided CBA group than in the conventional CBA group (6.0% vs. 19.4%; p = .019). CONCLUSIONS The EP-guided CBA approach can facilitate the ablation procedure and achieve low recurrence at 1 year after ablation.
Collapse
Affiliation(s)
- Yoshiaki Mizutani
- Department of Cardiology, Yokkaichi Municipal Hospital, Yokkaichi, Mie, Japan.,Department of Cardiology, Nagoya University Graduate School of Medicine, Nagoya, Aichi, Japan
| | - Satoshi Yanagisawa
- Department of Cardiology, Nagoya University Graduate School of Medicine, Nagoya, Aichi, Japan
| | - Masaaki Kanashiro
- Department of Cardiology, Yokkaichi Municipal Hospital, Yokkaichi, Mie, Japan
| | - Daiki Yamashita
- Department of Cardiology, Yokkaichi Municipal Hospital, Yokkaichi, Mie, Japan
| | - Jun Yonekawa
- Department of Cardiology, Yokkaichi Municipal Hospital, Yokkaichi, Mie, Japan
| | - Yuichiro Makino
- Department of Cardiology, Yokkaichi Municipal Hospital, Yokkaichi, Mie, Japan
| | - Takatsugu Hiramatsu
- Department of Cardiology, Yokkaichi Municipal Hospital, Yokkaichi, Mie, Japan
| | - Hitoshi Ichimiya
- Department of Cardiology, Yokkaichi Municipal Hospital, Yokkaichi, Mie, Japan
| | - Yasuhiro Uchida
- Department of Cardiology, Yokkaichi Municipal Hospital, Yokkaichi, Mie, Japan
| | - Junji Watanabe
- Department of Cardiology, Yokkaichi Municipal Hospital, Yokkaichi, Mie, Japan
| | - Satoshi Ichimiya
- Department of Cardiology, Yokkaichi Municipal Hospital, Yokkaichi, Mie, Japan
| | - Yasuya Inden
- Department of Cardiology, Nagoya University Graduate School of Medicine, Nagoya, Aichi, Japan
| | - Toyoaki Murohara
- Department of Cardiology, Nagoya University Graduate School of Medicine, Nagoya, Aichi, Japan
| |
Collapse
|
108
|
Suga K, Kato H, Inden Y, Yanagisawa S, Murakami H, Kada K, Tsuboi N, Murohara T. Permanent His-bundle pacing using distal His-bundle electrogram-guided approach in patients with atrioventricular block. PACING AND CLINICAL ELECTROPHYSIOLOGY: PACE 2021; 44:1907-1917. [PMID: 34520042 DOI: 10.1111/pace.14363] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/25/2021] [Revised: 08/09/2021] [Accepted: 09/12/2021] [Indexed: 11/29/2022]
Abstract
BACKGROUND Permanent His-bundle pacing (HBP) is effective and safe; however, the success rate of HBP is low, especially in patients with infranodal block. This study aimed to assess the efficacy and feasibility of HBP implantation using an electrophysiological guided approach targeting a distal His-bundle electrogram (HBE) in patients with atrioventricular block (AVB). METHODS Thirty-four consecutive patients with AVB (infranodal block in 28 patients) who underwent HBP were enrolled. During implantation, we attempted to target the distal part of the HBE (distal HBE) beyond the block site based on unipolar mapping. The His-capture threshold was evaluated for 1 year after implantation. RESULTS HBP was achieved in 26 patients and in 21 patients (75%) with infranodal block. Detection of distal HBE was significantly higher in the successful HBP group than in the HBP failure group (65.4% vs. 0%, p = .001). Among 15 patients with intra-Hisian block, 14 patients (93%) successfully achieved HBP with distal HBE detection. During the 1-year follow-up period, an increase in His-capture threshold by ≥1.0 V at 1.0 ms occurred in five (19.2%) of 26 patients. The increased His-capture threshold group exhibited significantly less detection of distal HBE (20% vs. 76.2%; odds ratio 0.078, 95% confidence interval 0.07-0.87, p = .038) and a higher His-capture threshold at implantation (2.0 ± 1.1 V vs. 1.1 ± 0.9 V; odds ratio 1.702, 95% confidence interval 1.025-2.825, p = 0.04) than the non-increased His-capture threshold group. CONCLUSION HBP implantation guided by distal HBE approach may be feasible with subsequent stable pacing in patients with intra-Hisian and atrioventricular nodal block.
Collapse
Affiliation(s)
- Kazumasa Suga
- Division of Cardiology, Japan Community Healthcare Organization Chukyo Hospital, Nagoya, Japan.,Department of Cardiology, Nagoya University Graduate School of Medicine, Nagoya, Japan
| | - Hiroyuki Kato
- Division of Cardiology, Japan Community Healthcare Organization Chukyo Hospital, Nagoya, Japan
| | - Yasuya Inden
- Department of Cardiology, Nagoya University Graduate School of Medicine, Nagoya, Japan
| | - Satoshi Yanagisawa
- Department of Cardiology, Nagoya University Graduate School of Medicine, Nagoya, Japan.,Department of Advanced Cardiovascular Therapeutics, Nagoya University Graduate School of Medicine, Nagoya, Japan
| | - Hisashi Murakami
- Division of Cardiology, Japan Community Healthcare Organization Chukyo Hospital, Nagoya, Japan
| | - Kenji Kada
- Division of Cardiology, Japan Community Healthcare Organization Chukyo Hospital, Nagoya, Japan
| | - Naoya Tsuboi
- Division of Cardiology, Japan Community Healthcare Organization Chukyo Hospital, Nagoya, Japan
| | - Toyoaki Murohara
- Department of Cardiology, Nagoya University Graduate School of Medicine, Nagoya, Japan
| |
Collapse
|
109
|
Ogawa T, Saito N, Fukuzawa K, Kiuchi K, Takami M, Hayashi M, Tanioka R, Ota M, Komoriya K, Miyawaki I, Hirata KI. Device nurse intervention facilitates the patients' adaptation to cardiac shock devices in the remote monitoring era. PACING AND CLINICAL ELECTROPHYSIOLOGY: PACE 2021; 44:1874-1883. [PMID: 34455601 DOI: 10.1111/pace.14348] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/28/2021] [Revised: 08/10/2021] [Accepted: 08/22/2021] [Indexed: 11/26/2022]
Abstract
BACKGROUND A substantial number of patients with shock devices (implantable cardioverter defibrillators [ICDs] or ICDs with resynchronization [CRTDs]) experience psychological distress. OBJECTIVE We investigated the device nurse telephone intervention's effect on improving the patient's adaptation to shock devices, quality of life (QOL), and anxiety in the remote monitoring era. METHODS The patient's adaptation to the device, health-related QOL, and anxiety were investigated by the modified Implanted Devices Adjustment-Japan score (IDAS), Short Form-36, and State-Trait Anxiety Inventory (STAI) before and 1-year after the device nurse telephone intervention, performed every 3 months. A total of 95 patients (median age 69 years and 25 females) participated. Sixty patients had ICDs and 35 CRTDs. Structural heart disease was observed in 72 patients, and idiopathic ventricular arrhythmias in the others. The mean left ventricular ejection fraction was 46% ± 15%. The median duration since the device implantation was 5.2 years. RESULTS The total IDAS score significantly improved from 28.42 ± 7.11 at baseline to 26.77 ± 7.68 (p = 0.0076) at 1 year. Both the state and trait anxiety significantly improved (from 38.9 ± 9.6 to 35.3 ± 9.0 [<0.0001] and 38.8 ± 10.3 to 36.2±9.8 [p = 0.0044], respectively). The prevalence of patients with a state and trait anxiety of more than 40 decreased from 44 (46%) and 38 (40%) patients before the study to 27 (28 %) and 32 (34 %) at 1 year. The SF-36 mental component summary score significantly increased (50.8 ± 8.3 at baseline to 53.1 ± 7.7 at 1 year, p = 0.0031). CONCLUSIONS The device nurse intervention facilitated the patient's adaptation to the shock device, increased the health-related QOL, and reduced the patient's anxiety.
Collapse
Affiliation(s)
- Tomomi Ogawa
- Division of Cardiovascular Medicine, Department of Internal Medicine, Kobe University Graduate School of Medicine, Kobe, Japan
| | - Nao Saito
- School of Nursing, Miyagi University, Miyagi, Japan
| | - Koji Fukuzawa
- Division of Cardiovascular Medicine, Department of Internal Medicine, Kobe University Graduate School of Medicine, Kobe, Japan.,Section of Arrhythmia, Division of Cardiovascular Medicine, Department of Internal Medicine, Kobe University Graduate School of Medicine, Kobe, Japan
| | - Kunihiko Kiuchi
- Division of Cardiovascular Medicine, Department of Internal Medicine, Kobe University Graduate School of Medicine, Kobe, Japan.,Section of Arrhythmia, Division of Cardiovascular Medicine, Department of Internal Medicine, Kobe University Graduate School of Medicine, Kobe, Japan
| | - Mitsuru Takami
- Division of Cardiovascular Medicine, Department of Internal Medicine, Kobe University Graduate School of Medicine, Kobe, Japan
| | - Megumi Hayashi
- Department of Nursing, Kobe University Hospital, Kobe, Japan
| | - Ryo Tanioka
- Department of Clinical Engineer, Kobe University Hospital, Kobe, Japan
| | | | | | - Ikuko Miyawaki
- Department of Nursing, Kobe University Graduate School of Health Sciences, Kobe, Japan
| | - Ken-Ichi Hirata
- Division of Cardiovascular Medicine, Department of Internal Medicine, Kobe University Graduate School of Medicine, Kobe, Japan.,Section of Arrhythmia, Division of Cardiovascular Medicine, Department of Internal Medicine, Kobe University Graduate School of Medicine, Kobe, Japan
| |
Collapse
|
110
|
Long P-wave duration immediately after pulmonary vein isolation on radiofrequency catheter ablation for atrial fibrillation predicts clinical recurrence: correlation with atrial remodeling in persistent atrial fibrillation. Heart Vessels 2021; 37:476-488. [PMID: 34432100 DOI: 10.1007/s00380-021-01932-w] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/27/2021] [Accepted: 08/20/2021] [Indexed: 01/22/2023]
Abstract
P-wave morphology reflects atrial remodeling and indicates prognosis after radiofrequency catheter ablation (RFCA) for atrial fibrillation (AF). The impact of p-wave morphology after excluding the effect of pulmonary vein (PV) substrate on outcomes is unknown. We evaluated the p-wave morphology on electrocardiography immediately after PV isolation for clinical outcomes. Eighty-four consecutive patients (47 with paroxysmal AF and 37 with persistent AF) who underwent RFCA were included. P-wave duration (PWD) and amplitude in all leads were examined during sinus rhythm immediately after PV isolation. We evaluated the relationship between electrocardiogram parameters and AF recurrence, according to the type of AF and following ablation, and the correlation with left atrial (LA) volume, low voltage ratio, and fixed conduction time. During 12 months of follow-up, 20 patients experienced recurrence. The cut-off value of PWD > 120 ms in lead I showed a sensitivity of 75% and specificity of 69% for predicting recurrence. PWD was significantly correlated with LA volume, low voltage, and conduction velocity. Significantly higher recurrence rates were observed in patients with PWD > 120 ms than in those with PWD ≤ 120 ms (p < 0.001), and the difference was more pronounced in patients with persistent AF. Multivariate analysis demonstrated that PWD > 120 ms was independently associated with recurrence in the total population (hazard ratio 2.00; 95% confidence interval 1.27-3.22; p = 0.003) and in patients with persistent AF. In conclusion, long PWD after PV isolation predicts AF recurrence, which might be associated with the extent of the LA substrate in persistent AF.
Collapse
|